Report (71)
' -- - -;,!:::414,- k3- 60� S L3 `y�ac,rt�c. . k+1-0 RECEI If Honeywell N 0 V 12 018 I Acdressable Fire Alarm Control Panels Ea CITY OF TIGARD BUILDING DIVISION 6700 o Acdressable Fire Alarm Control Panel The 6700 is an addressable fire alarm control panel(FACP)that is a direct replacment for the 5700 FACP.The 6700 can be configured to o achieve a point capacity of up to 100 points.It has one built-in signaling line circuit(SLC),which can support 50 System Sensor (SK) sensors and 50 SK modules or 50 Hochiki (SD)devices. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable.A designated panel is configured as the communicator for all panels in the link for convenient single-point communications.The 6700 also has a built-in, dual-line POTS and IP communicator with additional cellular options available. 6700 • The 6700 system can be enhanced by adding modules such as the The 6700 supports a variety of devices,including 6860 remote annunciator which also has four programmable function the 6860,5860,and 6855 remote annunciators, buttons to help automate tasks and reduce time spent at the panel. 5824 serial parallel printer interface module(for printing system reports),the 5496 NAC expander, SWIFT®wireless compatibility provides options for wireless detection 5895XL power module,and SK or SD devices. through a Class A mesh network.It is ideal for hard-to-wire locations, buildings where new wiring is not allowed,or to provide an easy install fire system for new construction projects.SWIFT devices can be combined with other hard-wired 6700 compatible devices.SWIFT is only compatible with System Sensor(SK)devices.It is not compatible COP/ with Hochiki(SD)devices. Off 1Cj The 6700 also has a form-C trouble relay,two programmable form-C relays,along with powerful features such as drift compensation,pre- trouble maintenance alert,a built-in sensor test to comply with NFPA 72 calibration testing requirements,and calibration trouble alert. r FEATURES 8 BE.NEH I S • Capable of providing • Convenient • 6860 annunciator with • Programmable date • 125 software zones up to 100 points to field-upgradeable a 4 x 40 large display setting for automatic and 125 output satisfy smaller firmware and convenient groups for flexible • Four user- installation needs . Built-in dualpath Daylight Saving Time design options programmable buttons changes • Connect up to 17 POTS and IP minimize time spent panels on one site with communications executing complex or • JumpStart auto convenient single- with optional cellular routine tasks programming reduces point access using the models available for • guilt-in USB interface installation time SK-NIC Network reliable backup for convenient and Interface Card. reporting Connected panels can quick programming have mixed compatible FACP models SIGNAL LINE CIRCUIT(SLC) PROGRAMMING ORDERING INFORMATION The 6700 SLC loops support multiple The 6700 system offers several options 6700:Addressable Fire Alarm device types,maintenance alerts,and a to simplify and speed-up programming. Control Panel.(Red cabinet) built-in sensor test to comply with NFPA Jumpstart`'auto programming 72 calibration testing requirements. minimizes programming required to COMPATIBLE ANNUNCIATORS start a new system.The built-in keypad, 6860:4x40 LCD remote fire INDICATOR LIGHTS annunciator(4 lines and up to or the 6860,5860 or 6855 remote • General Alarm(Red):Flashes if in annunciators give you on-site access to 160 characters)per system;four alarm;solid when alarm is silenced current system programming. programmable buttons • Supervisory(Yellow):Flashes if a Programming can also be accomplished 5860:4x20 LCD remote fire supervisory condition exists;solid using the Windows'-based Honeywell annunciator.5860 is gray;5860R is red when supervisory is silenced Fire Software Suite(HFSS)program. 6855:4x20 LCD remote fire annunciator • System Trouble(Yellow):Flashes SOFTWARE TOOLS if a trouble condition exists; 5865-3 or 5865-4:LED annunciators SKST:Silent Knight Selection Toot solid when trouble is silenced can display up to 30 LEDs(15 red and provides the installer or design architect 15 yellow).The 5865-4 has key switches • System Silenced(Yellow): with a Windows'software system for silence and reset,and a system On when an alarm,trouble or configuration toot to create a detailed trouble LED. supervisory condition has been Bill of Material(BOM)and battery 5880:The 5880 LED/10 module silenced but not yet cleared calculations. has 40 programmable LED outputs • System Power(Green):Flashes HFSS:Honeywell Fire Software Suite *and eight supervised dry contact for AC failure;solid when provides communication and panel inputs which are useful for custom power systems are normal programming,detector status,event applications.You can use up to eight history and additional data. Requires a USER INTERFACE 5880 modules on one control panel for PC running Microsoft`Windows®. maximum flexibility.Its compact size The 6700 built-in 4 x 20 annunciator with 80 character LCD display ADDITIONAL INFORMATION allows mounting inside the annunciator, and large easy-to-use tactile Twisted-unshielded pair wire is or in an accessory cabinet. touchpad can be used for system recommended.The 6700 also has 6700 COMPATIBLE DEVICES AND operation,programming and 13 preset notification cadence patterns ACCESSORIES See the data sheets listed below for a maintenance.It has five LEDs for (including ANSI 3.41). complete listing of the SK,SD or SWIFT alarm,supervisory,system trouble, AGENCY LISTINGS AND APPROVALS devices. system silenced and system power. 53623:SK Devices Data Sheet NPFA 13,NFPA 15,NFPA 16,NFPA 70, 53624:SD Devices Data Sheet System operations include silencing NFPA 72:Central station;remote 350614,350616&350618:SWIFT alarms and troubles,resetting alarms Signaling;Local Protective Signaling wireless devices and the disp ay o a arm rou• es an. Fur a Lomptete anK LuI ei,t listing of -- `"" °• '" rot a in compatible devices and accessories,visit Unit;Water memory.The system s non-volatile Delugeg service. www.silentknight.com event history buffer stores 1,000 Suitable for automatic,manual, Important: You cannot mix SK and SD events for viewing from the built- waterflow,sprinkler supervisory(DACT devices in the same fire alarm system. in or remote annunciator.System non coded)signaling services operations can be initiated with a • UL Listed:S2766 mechanical firefighter's key or a • CSFM 7165-0559:0501 valid 4-to 7-digit operator's code. • FDNY COA#6250 Page 2 of 4—351607:B 9/26/2018 SK COMPATIBLE ADDRESSABLE B200S-LF(-IV,-WH):Low-Frequency WSK-WGI:Wireless Gateway DEVICES intelligent sounder base WSK-PHOTO:Wireless Photoelectric SK-ACCLIMATE:Multi criteria B200S-LF:Low-frequency intelligent smoke detector photoelectric smoke detector with thermal sounder base WSK-PHOTO-T:Wireless Multi-criteria 135°F fixed temperature B224R13(-IV,-WH):Relay base photoelectric smoke detector with thermal SK-BEAM:Reflected beam smoke detector B224RB: Relay base detection(135°F fixed temperature)and without test feature B224B1(-IV,-WH):Isolator base B510W 4"base SK-BEAM-T:Reflected beam smoke B224B1: Isolator base WSK-HEAT:Wireless Heat,(135°F fixed detector with test feature temperature)and B510W 4"base SK-CONTROL:Supervised control module SD COMPATIBLE ADDRESSABLE WSK-HEAT-ROR:Wireless heat,ROR SK-CONTROL-6:Six circuit supervised DEVICES (135°F fixed temperature)and B510W 4" control module SD505-6AB:Addressable 6"base base SD505-6IB:Addressable 6"short circuit WSK-MONITOR:Wireless monitor module SK-DUCT:Photoelectric duct smoke isolator base detector with extended air speed range WSK-RELAY:Wireless relay module SK-FIRE-CO:Four criteria fire and carbon SD505-6RB:Addressable 6"relay base W-USB:SWIFT Tools USB transceiver used monoxide detector SD505-6SB:Addressable 6"sounder base for communication with SWIFT devices SK-HEAT:Fixed thermal detector(135°F) SD500-AIM:Addressable input module SK-HEAT-W:Fixed thermal detector (switch input) SBUS ACCESSORIES (135°F),white SD500-ANM:Addressable notification 5496:A 6 amp notification power expander module with four power-limited notification SK-HEAT-ROR:Fixed rate of rise detector SD500-ARM: Addressable relaymodule appliance circuit outputs. (135°F) P SK-HEAT-ROR-W:Fixed rate of rise detector SD505-DTS-K: Remote test switch 5883:Relay interface.Provides 10 Form C (135°F),white and LED indicator for the SD505-DUCTR relays. SK-HEAT-HT:Fixed high temperature SD505-DUCT:Addressable Duct Smoke 5824:Serial/Parallel printer interface thermal detector(190°F) Detector. module for printer connection. SK-HEAT-HT-W:Fixed high temperature SD505-DUCTR:Addressable Duct 5895XL:Power supply with six Flexput" thermal detector(190°F),white Detector housing with relay base. circuits,and two Form C relays.Max.16 per SK-ISO:Fault isolator module SD505-HEAT:Absolute temperature heat system. detector.Trip point range from 5815RMK:Remote mounting kit. SK-MINIMON:Mini monitor module 135°F-150°F(0°C-37°C). Dimensions 10 3/8"W x 10-3/16"H x 3"D SK-MONITOR:Monitor module SD500-LIM:Addressable Line isolator SK-MONITOR-2:Dual input monitor module COMMUNICATION OPTIONS module SD500-MIM:Addressable Mini input CELL-CAB-SK:Cellular communicator, SK-MON-10:10 input monitor module monitor module(switch input) metal enclosure with tock/key* SK-PHOTO:Photoelectric smoke detector SD505-PHOTO:Photoelectric smoke CELL-MOD:Cellular communicator,plastic SK-PHOTO-W:Photoelectric smoke detector enclosure* detector,white SD500-PS/-PS DA:Addressable Single or *Sole path,powered by panel. SK-PHOTO-T:Photoelectric smoke detector dual action pull station IPGSM-4G:Dual path fire alarm with thermal(135°F fixed temperature) SD500-SDM:Addressable smoke detector communicator,cellular and/or IP(primary or module backup,selectable) SK-PHOTO-T-W:Photoelectric smoke SK-IP-2:Remote reporting via the Internet. detector with thermal(135°F fixed AUDIBLE/VISIBLE DEVICES Requires a VisorAlarm®receiver at the central temperature),white These AV devices are all 2-wire.Color:"R" station SK-PHOTOR:Photoelectric detector with indicates red;"W"denotes white.For a remote test capability MISC.ACCESSORIES complete listing of Silent Knight AV devices SK-PHOTO-R-W:Photoelectric detector go to www.silentknight.corn. SK-NIC: Network Interface Card. Provides a with remote test capability,white common communications link for the 6700 SK-PULL-SA:Addressable single action CHSRL/CHSWL:Wall chime/strobe CHSCRL/CHSCWL:Ceilingchime/strobe SK-NIC-KIT:Installation Accessory Kit pull station SK-FML:Fiber-Optic Multi Mode,transmitter SK-PULL-DA:Addressable dual action putt CHRL/CHWL:Wall chime and receiver station HRL/HWL:Wall horn SK-RELAY:Addressable relay module P2RL/P2WL:Wall horn/strobe SK-FSL:Fiber-Optic Single Mode PC2RL/PC2WL:Ceilinghorn/strobe RBB:Remote battery box accessory cabinet SK-RELAY-6:Addressable Six relay control for batteries that are too large to fit in the module SRL/SWL:Wall strobe FACP cabinet.Dimensions:16"Wx 10"H x SK-RELAYMON-2:Addressable Dual relay/ SCRL/SCWL:Ceiling strobe 6"D(406mm W x 254mm H x 152mm D). monitor module SPSCRL/SPSCWL:Ceiling speaker/strobe SK-SCK: Seismic Compliance Kit used to SK-ZONE:Addressable zone interface SPSRL/SPSWL:Wall speaker/strobe securely fasten batteries to the fire panel. module SPRL/SPWL:Watt speaker SK-ZONE-6:Six zone interface module SPCRL/SPCWL:Ceiling speaker B300-6(-IV):6"base for SK-W Series B210LP:6"mounting base SWIFT WIRELESS DEVICES B501(-BL,-IV,-WHITE):4"flangeless base SWIFT is only compatible with 8501:4"Flangeless mounting base System Sensor(SK)devices.It is not B200S(-IV,-WH):Intelligent sounder base compatible with Hochiki(SD)devices. B200S:Intelligent sounder base Page 3 of 4—351607:8 9/26/2018 6700 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS(NACs) Flexput°',Honeywell", Two programmable circuits which can be JumpStartr",Silent Knight°, Overall Dimensions:12.71"W x 15.12"H x 3.33"D SWIFT",and System programmed individually as: Weight:15 lbs. Sensor"are registered NACs:2.5A 27.4VDC per circuit,power-limited trademarks of Honeywell Color:Red (with a panel maximum current of 2.5A) International Inc. E NVIRONMENTAL Auxiliary Power Circuits:2.5A @ 27.4VDC per g circuit,power-limited Hochiki°is a registered Operating Temperature:32°F to 120°F (0°C to trademark of Hochiki 49°C) Corporation.Microsoft' Supports Class B(Style 4)and Class A(Style 6 or 7) and Windows"are . Humidity:0 to 930/o relative humidity(non configuration for the SLC registered trademarks of condensing) Microsoft Corporation. E LECTRICAL WIRING:See the product manual for wiring details This document is not 6700 PrimaryAC:120 VAC @ 60 Hz,1.5A Total intended to be used for installation purposes.We Accessory Load:2.5A @ 27.4 VDC power-limited try to keep our product Standby Current:165mA information up-to Alarm Current:310mA date and accurate.We Battery Charging Capacity:7 to 35AH cannot cover all specific applications or anticipate Battery Size:7AH max.allowed in control panel all requirements.All cabinet.Larger capacity batteries can be housed in specifications are subject RBB accessory cabinet. to change without notice. For Technical Support,call 800-446-6444. Honeywell Silent Knight 12 Clintonville Road Northford,CT 06472 Honeywell 800-328-0103 351607 I B I 09/18 ri SILENT' www.sitentknight.com ©2018 Honeywell International Inc. Ilia KNIGHT DBG From Tyco Security Products HSPA Universal Wireless Commercial Fire Alarm Communicator osc 3G4010CF Features That Make a Difference: • Uses HSPA(3G)network for high-speed, reliable and low- cost communications to an IP receiver 3G technology from DSC! • Automatically switches to 2G (EDGE/GPRS) if 3G service is The 3G4010CF connects the alarm protected premises within not more not available control panel to the Cellular network than 24 hours of the failure. • Compatible with control panels and reports alarm signals directly to that communicate using Contact a monitoring station receiver How it Works ID or SIA(300 baud)formats (Sur Gard System I IP/II/III/IV/5).The The 3G4010CF can be used as 3G4010CF uses the Cellular network either a Sole Communicator or as a • Full event reporting to ensure low-cost, high-speed and Backup Communicator.When being • 4 on-board inputs with NC, NO reliable alarm communications and is used as a Sole Communicator the or SEOL supervision compatible with control panels that p 3G4010CF will replace the phone communicate using the Contact ID or • 4 on-board outputs(open line connection on the panel and p ( p SIA(300 baud)format. as soon as it detects that an alarm collector) The 3G4010CF is compliant needs to be transmitted it will send • Activation and initialization via with the latest requirements for the alarm across the Cellular network automated telephone activation Communications Methods as per immediately.When being used as a system(VRU), web-user or UL864 and NFPA72 2010 and backup the communicator assesses mobile interface provided by 2013 Editions. It can be used in the connection to the PSTN phone C24 Communications Fire Monitoring applications as a line,and only in the event of a phone • View communicator status single communications technology, line failure will it send all alarm traffic directly from your mobile phone in which case any failure of the across the Cellular network to the to support on-site or remote communications path shall be monitoring station. troubleshootingannunciated at the supervising station within 5 minutes(NFPA72 2010)or In instances where the control panel • Compatible with Sur-Gard® does not support Contact ID or 1 hour(NFPA72 2013)of the failure, System I-IP/11/III/IV/5 monitoring or it can be used as part of a multiple SIA(300 baud),the 3G4010CF has inputs pre-set to transmit fire alarm, station receivers communications technologies(for fire supervisory or system trouble. • Includes UL listed power example in conjunction with a DACT). supply,transformer and 7 Ah When used as a back-up provision Alarm signals are transmitted directly rechargeable battery shall be made to monitor the integrity without the need of a clearinghouse of each communication path and to the IP linecard of the monitoring • UL 864 listed failure of any communications station receiver(Sur-Gard®System • CSFM listed path shall be annunciated at the I-IP/II/III/IV/5). supervising station and at the communications Contact your DSC distributor. www.dsc.com 11-888-888-7838 DSD From Tyco Security Products Activating & Initializing the Unit Rate Plan Activating and initializing the 3G4010CF can be done using Cost-effective rate plans have been negotiated and are the automated telephone activation system(VRU), mobile available through authorized master resellers. Contact your interface or web-user interface provided by monitoring station or visit www.connect24.com to find a C24 Communications. No special tools are required. master reseller.When used as a sole communicator,the 3G4010CF requires use of the 4MB(NFPA72 2010)or Mobile Site for Easy Installation and 500kB(NFPA72 2013)rate plans to support the supervision Comprehensive Maintenance requirements. C24 Communications mobile site(m.connect24.com) Specifications makes the installation a simple process and offers intuitive trouble-shooting features, cutting down on time and cost Dimensions 11-1/2"x 10"x 3" allocated to maintenance. (290 mm x 254 mm x 75 mm) Input Voltage 120 VAC Current Draw 200 mA(standby) 11111111=1116 400 mA(transmitting) C84 0 0 0 .....44. Operating Environment 32°to 120°F(0°to 49°C) os=a" -,,. 0 `; Weight 12.8 lbs(5.8 kg) Optional Acessories 111111111111Mil ‘60"' Model Description UL Listing GS-15ANT 15 ft extension antenna(internal use) The 3G4010CF is UL listed under File S4019, Listing guide GS-25ANT 25 ft extension antenna UOXX,as a sole or backup communicator for Commercial Fire (internal/external use) monitoring installations.When used as a sole communicator GS-50ANT 50 ft extension antenna under NFPA72 2010 guidelines the 3G4010CF will send (internaVexternal use) its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window.When used as a sole communicator under NFPA72 2013 guidelines the 3G4010CF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window.When used as a backup_communicatnr the 3G4010CF_will monitor the other communication method(DACT)and send a daily test transmission o the supervising station. CSFM Listing The 3G4010CF has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: 3G4010CF-USA Universal Wireless Commercial Fire Alarm Communicator (U.S. Model/SIM Card Included) a cOmmurltCatlons For product informatton' moa . www.dsc com Prodi ct spesrthcaiior and a ra Watley so,'.Ject to change wohor.t notice,Certain ,; product names mentioned harem maybe trade names and/or registered trademarks of other companies. 02015 Tyco Security Products .SYSTEM �$ SENSOR .0-41 Outdoor Selectable- r` ■ iso • Output Horns, • Strobes, and Horn Strobes for Wall Applications SPECT # - rt SpectrAlert®Advance outdoor audible visible products Grany nom are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes, and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING ' corrosion. Knock-outs located on the back eliminate the need to drill ® I` I_ holes for screw-in mounting.Plastic and metal weatherproof back ® MEA boxes come with 34-inch top and bottom conduit entries and 34-inch 7300-1653'187(outdoor strobes) LISTED 7125-1653188(horn strobes, knock-outs at the back.A screw-in NPT plugwith an 0-ringgasket S40t1(chimes,horn strobes,horns) APPROVED approved chime strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications Architect/Engineer Specifications a„� General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115,135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens, 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 I I UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) q.,ux :" UL Max.Horn Current Draw(mA RMS) � , 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) L ' t 8-17.5 Volts 16-33 Volts DC Input 15 15175 15 15/75 30 75 95 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Strobe Output(cd) Switch Sound Volts Volts Reverberant Anechoic Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 - 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 75 44 4 Temporal High 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tsettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diagrams 4.7" 72.5 ,,..-,..„1-: . , 4 \ I- /. (,, 5.6" O Ill 1 , O���, 1111 Wall-Mount Horn Strobes � Wall Plastic Weatherproof Back Box 111/1111111'Z'ik; AM, 0 INI 0 II � ;0,71-.10_46®IP`�t1 11111111 :7-7-1,1 Li 1.1111 Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK"t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor,120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box - SA-WBBW White,Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela�lasettings.When replacing standard outdoor units both the device and back box must be replaced. SYSTEM ©2012 System Sensor. SENSOR �r 3825 Ohio Avenue•St.Charles, IL 60174 Productspecificatlonssubjecttochangewithou:notice.Vetsystemsensor.com SENSOR Phone:800-SENSOR2•Fax:630-377-6495 for current product Information,AcludIng the latest vereon of this data sheet. AVDS01201•3/12 INTELLIKNIGHT ACCESSORY 14SILENT SK-Monitor 11 KNIGHT by Honeywell Intelligent Monitor Module The SK-Monitor module provides an interface to contact devices, such as security contacts, waterflow switches, or pull stations. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Monitor is an addressable monitor module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Monitor is intended for use in intelligent, two-wire systems, where individual address of each module is selected using the built-in rotary switches. The SK-Monitor supports Class A supervised or Class B 1. rimer supervised wiring to the load device. Conventional 4-wire w,tq smoke detectors can be monitored for alarm and trouble "` conditions. Features � r • Single contact monitor ` • Support for Class A and Class B wiring • Fully supervised • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate SK-Monitor • Rotary address switches for fast installation • SEMS screws for easy wiring Specifications • UL Listed Physical Installation Height: 4.5" (11.4 cm) The SK-Monitor mounts directly into a 4"square electrical Width: 4" (10.2 cm) box. The box must have a minimum depth of 2-1/8".A Depth: 1.25" (3 cm) surface mount electrical box (System Sensor® PN Shipping Weight: 6.3 oz (196 g) SMB500) is available from Silent Knight. Electrical Compatibility Operating Voltage: 15—32 VDC The SK-Monitor is compatible with the following Current Draw(LED on): 5.0 mA max IntelliKnight FACP's: Operating Current (LED flashing): 375 pA 5700 5808 5820XL 5820XL-EVS INTELLIKNIGHT ACCESSORY Model SK-Monitor Intelligent Monitor Module TDEVICE t a'I. '�+r 4".+r'.4 s 4114. + '''"'. C'.,: 11. FREVIOUB DEVICE I IICNITOR X AM NUMUER OF LL USTED CONTACT f-"1 MCDULE I"y CLOSUFIE Dencss MAY BE USED.CO NOT MXp CONNECT MCOLLE:-TO LISTED COMPATIBLE FRE ALAFIAINT44TNG,SLPEFMECFK.#{ 1fe • CONTROL PANELSONLY EEC LFUTYDEVICES ONTHESAYE MUDIAE. ill 1 I 47K EOL i•._ I t RESISTOR I �- I ELR.4M 1 E 5I ... + y, " - #F ,A INITIATNO DEVICE CF1CUIT loo,i-NFPA STYLE 9 POWER UMTED:4 CIAMAX.+011VDCUAX INSTALLT CLOSUFE DEVICES PER ALL WRING ENOWNI I SLFER'NEED AND POWER LIMITED CONIAGUANLFALTUFEWSINSTALULTICN MSTFLICr1 . 2-Wire Initiating Circuit Configuration, NFPA Style B TO NEXT FROM PANEL OR _ DEVICE -+rt ;41111.411M u►401, 4111,w fi r•. /' .. - 'R.61''61'.+ +1 PREVIOUS DEVICE ♦ MONITOR a ANY NUMBER OF IA.LISTED CONTACT MODULE CLOSURE DEVICES MAY BE USED DO NOT MIX $ $ CONNECT MODULES TO LISTED COMPATIBLE FIRE ALARM INTIATING,SUPERVISORY,OR 6 Od a 1 NOTIFER CONTROL PANELS ONLY SECURITY DEVICES ONTHE SAME MODULE II • ri1 0 1 I r 1 EOL RESISTOR IS I c;/ an o an .it INTERNAL AT Q Q •1R'' Pr TERMINALS 8&9 I J INSTALL CONTACT CLOSURE DEVICES PER ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED MANUFACTURERS INSTALLATION INSTRUCT IONS. 4-Wire Initiating Circuit Configuration, NFPA Style D Standby Current: Environmental 400 pA max @ 24 VDC (one communication every 5Operating Temperature: 32°F— 120°F (0°C—49°C) sec with 47K EOL) Humidity: 10%—93% non-condensing 550 pA max @ 24 VDC (one communication every 5 . sec with EOL<1K) 5.5 mA(with LED latched on) Ordering Information SK-Monitor Monitoring Module LED Current: 5.5 mA(with LED latched on)End-of-Line Resistance: 47K S2 Accessories Initiating Device Circuit Wiring Resistance: 1,500 S2 max SMB500 4" Square Surface Mount Electrical Box SLC Loop Resistance: 40 52 max. SILENT This document is not intended to be used for installation purposes.We try to Assembled in USA keep our product information up-to-date and accurate.We cannot cover all `j KNIGHT specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information,contact Silent Knight 12 FORM#350131 Rev E by Honeywell Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203) ©2013 Honeywell International Inc. 484-7118.For Technical Support,Please call 8200-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY 41% SILENT SK-Photo, SK-Photo-T KNIGHT and SK-PhotoR by Honeywell Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description • Optional remote LED annunciator (System Sensor®PN RA100Z) SK-Photo and SK-Photo-T are plug-in • Plug-in mounting provides ease of ) type smoke sensors that combine a installation ` -: _ photoelectric sensing chamber with • Tamper-proof feature available on addressable analog communications. mounting bases ? 4 44;14:0447 Point ID capability allows each detector's address to be set with rotary • Listed for use in duct applications address switches, providing exact • Rotary address switches for fast detector locations for selective installation maintenance when chamber • UL Listed contamination reaches unacceptable • FM Approved 1 levels. r, � Specifications iiM SK-Photo and SK-Photo-T have a 4 unique optical sensing chamber that is Physical engineered to sense smoke produced Height: 2.0"(5.0 cm) SK-Photo (Base included) by a wide range of combustion Diameter:4.1" (10.4 cm) installed in sources. In the SK-Photo-T, dual B501 base Installation electronic thermistors add 135°F(57°C) thermal technology to maximize Electrical detection. Operating Voltage: 15-32 VDC The SK-Photo and SK-Photo-T plug Standby Current: into a compatible IntelliKnight-series The SK-PhotoR is a remote test detector base.The SK-PhotoR is a capable detector for use with the 300 pA @ 24 VDC Maximum remote test capable detector head DNR/DNRW duct smoke detector. (not Alarm Current: 6.5 mA @ 24 VDC max included within the DNR(W)duct included) (with LED on) smoke detector. EnenTemperature Compatibility Operating Temperature Features SK-Photo: 32°—120°F(0°C—49°C) SK-Photo, and SK-Photo-T are • Sleek, low-profile design SK-Photo-T: 32°— 100°F(0°C—38°C) compatible with the following detector • Base included Humidity: 10%—93% non-condensing bases: • Reliable analog communications for Other Ratings 6210LP 6"base(included) trouble-free operation SK-Photo-T Thermal: Fixed B501 2 wire base temperature set 135°F(57°C) B224RB Relay base • Age resistant polymer housing p point 135 F822461 Isolator base • Dual electronic thermistor design on Velocity: 0—4000 fpm (0—20 m/sec) B200SR Sounder base the SK-Photo-T The SK-Photo, SK-Photo-T, and SK- • Superior EMI resistance for reliability PhotoR are compatible with the • Simple field cleaning for code following IntelliKnight FACPs: compliance 5820XL • Variety of mounting options to meet 5820XL-EVS any application 5808 • Dual LED indicators for 360°visibility 5700 5600 (Rev 2.0 or higher) • Detector transmits signal to indicate maintenance is required i 'i INTELLIKNIGHT ACCESSORY Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B210LP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady.The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector.The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. SLC }I / ---1N OUT f (' rif a IN St grainicauni 1 Compatible FRCP i RA100Z(Optional) (r 11.16.4011111 (1,i:qv; „de 1,..,°,1hi°,.,10 40-1 ,iito \pi \iiiingli Class A Optional Wiring , Wiring SK-Series Detector Mounting Bases SILENT0 This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350118 Rev E subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road,Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support, Please call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY 41% SILENT SK-Pull-SA and SK-Pull-DA ii KNIGHT by Honeywell Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only I one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight 1 DPULL IDU WN 1 Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition SILENT • Dual-color LED is visible through handle of station blinks "�""' �+ green to indicate normal operation and remains steady red in an alarm condition SK-Pull-SA • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks F • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms 1 PUSH IN guidelines (Section 4.1.3[13]) PULLOOWNS • Meets ADA requirement for 5 lbs maximum pull force to --- active • Shell, door, and handle molded from durable LEXAN® ; y ti • Reliable analog communications for trouble-free operation • Braille text on station handle SK-Pull-DA • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled The SK-Pull-SA and SK-Pull-DA are compatible • Rotary address switches for fast installation with the following IntelliKnight FACP's: 5600 • UL Listed, including UL 38, Standard of Manually Actuated 5700 Signaling System 5808 5820XL 5820XL-EVS INTELLIKNIGHT ACCESSORY Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. Class A a?,r,as Class B `— Compatible FRCP f t I, I t '- 9 T i I r va m r a e Ii 1 1 I 1 I — 1 t Class A Wiring: -`" Class B Wiring: nn- WO t '.: 1'. Wiring SK-Pull-SA&SK-Pull-DA Pull Stations Specifications Electrical Physical Operating Voltage: 15-32 VDC Height: 5.5"(14 cm) Average Operating Current(LED flashing): 300 pA Width:4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32°–120°F(0°C–49°C) Bi-Colored LED: Humidity: 10%–93% non-condensing • Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST)normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-I/O Surface backbox 0 SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover KNIGHT all specific applications or anticipate all requirements.All specifications are FORM#350135 Rev C subject to change without notice.For more information,contact Silent Knight 12 Clintonville Road, Northford,CT 06472-1610 ©2013 Honeywell International Inc. by Honeywell Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support, Please call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY SILENT SK-Relay KNIGHT by Honeywell Intelligent Relay Module The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built in rotary switches. For more information about the IntelliKnight system, or to locate you nearest source, please call 800-328-0103. Description The SK-Relay is an addressable relay module for use withpw-p,.a Silent Knight IntelliKnight series fire alarm control panels ' (FACPs). The SK-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification , a -. appliance circuit. 4.5 The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK- SK-Relay Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the Installation SK-Relay, the relay is triggered by the FACP. The SK-Relay mounts directly into a 4" square Features electrical box. The box must have a minimum • Two sets of Form C contacts depth of 2-1/8".A surface mount electrical box (System Sensor® PN SMB500) is available from • Rotary address switches for fast installation Silent Knight • Contacts are rated for a variety of amps (see Specifications) Compatibility • Panel controlled status LED that flashes green in normalThe SK-Relay is compatible with the following state and is solid red in alarm IntelliKnight FACP's: 5820XL • Relay programming is completely flexible—can be mapped 5820XL-EVS to zone conditions 5808 5700 • Polling LED visible through the cover plate 5600 (Rev 2.0 or higher) • Attractive ivory cover plate • SEMS screws for easy wiring • UL Listed . INTELLIKNIGHT ACCESSORY Model SK-Relay Intelligent Relay Module 'I To Next Device If Any Wiring to Terminals 3—9 is Not Power + / Limited,the CB500 Barrier is Required.The CB500 Includes a Non-Power Limited Label, f flWhich Must Be Placed Over the Power Limited '0 O O ' Terminal Information on the Name Plate Label. ° Relay Common 2 al s tiOnd Normally Closed 2 ! ' e ilt:It1 'v., Normally Open 2 lei 7:,,:• 2 Relay Common 1 `"i s el' 8 1 1 From Compatible FACP Normally Closed 1 1.' 5 "..q-It 4 + or Previous Device ,.__14ones• Module Does Not Supervise (1 O 2 ° 0 Normally Open 1 Controlled Circuits .. ( � U U Wiring the SK-Relay Module Specifications End-of-Line Resistance: not used Physical Standby Current: 300 pA max @ 24 VDC (one Height: 4.65" communication every 5 sec with LED enabled) Width: 4.25" LED Current: 5.5 mA(with LED latched on) Depth: 1.1" SLC Loop Resistance: 4052 max. Shipping Weight: 6.3 oz (196 g) Relay Contact Ratings Electrical 3.0A @ 30 VDC resistive Operating Voltage: 15—32 VDC 0.9A @ 110 VDC resistive Current Draw: 6.5 mA max (LED on) 0.9A @ 125 VAC resistive - Operating Current: 0.5A @ 125 VAC inductive (PF = .35) = 230 pA(LED flashing)direct poll 0.7A @ 75 VAC inductive (PF = .35) 255 pA(LED flashing) group poll la SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350127 Rev D subject to change without notice. For more information,contact Silent ©2013 Honeywell International Inc. by Honeywell Knight 12 Clintonville Road,Northford,CT 06472-1610 Phone: (800)328-0103,Fax:(203)484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com