Plans (4) FPS ' 0 i / - (I) t 1 6 RE NOV 9 2017 BUILDING DIVISION DURHAM IPS BUILDING C S LEAN WATER ERVICES w L._, cc _ FIRE ALARM SYSTEM U 2 U w Q w(.,_, >_ LU Lu LU 16060 SW 85TH AVE . Q mm i, N L.]TIGARD OR 97224H O Q f,iO Z 6 II g ti iii;; 1 /� a) •tQ O !ilk tn 0 O hi Li O O U "V 7 Eli 6 O 2 6 v v X c 1 A, L 11 O LL t 3 ill Etx � 0 t\ � ''AA 6 N ,0- ISS VI Z 0 N Set O !IA rn GENERAL WIRING NOTES VICINITY MAP PROJECT DESCRIPTION- SCOPE OF WORK sLI $ O !e 1. ALL CONTROL PANEL WIRING IS TO BE LABELED WITHIN 1" OF THEr'''''''''''''' =; r r.1ROVIDE A BUILDING FIRE ALARM SYSTEM TO MEET 2014 O.S.S.C. Eii TERMINATIONS, USING AN INDELIBLE, FINE TIP MARKER ON WHITE SHRINK ORBOCUPANYAND201NFPA . �� gds , 111,41.10.1\ ill TUBING, OR ON SCOTCHBRANDWHITELECTRICATAP . .,�r.�'��r,M.�>Y�.;«amu� z.�r.�,54�'L�c�s^�w��+n ��3, e .; . iE2. ALL CONTROL PANELWIRINGWILL BESCUREDTOSCRWMOUNTED ' . MONITOR BUILDING FIRE SPRINKLER SYSTEM. ANCHOR BLOCKS OR OTHER SOLID STRUCTURES WITHIN THE ENCLOSURE. >:; 2. PROVIDE NOTIFICATION THROUGHOUT BUILDING. '° 3. PROTECT ALL CONTROL EQUIPMENT FROM METAL DRILLING AND CUTTING ` `�. $ 3. PROVIDE MANUAL ALARM STATIONS AT LOBBY 101 & WORK DEBRIS. VACUUM ENCLOSURE(S) AT INSTALLATION COMPLETION. ' AREA 129 EGRESS POINTS. 4. MAINTAIN SEPARATE WIRE HARNESSES FOR INPUT, OUTPUT, AND NON- 4. PROVIDE REMOTE FIRE ALARM ANNUNCIATOR AT LOBBY 101. POWER LIMITED CIRCUITS, AND MAINTAIN AT LEAST 2" SEPARATION OFA' 5. PROVIDE SMOKE & HEAT DETECTION THROUGHOUT FACILITY. THE "PLEA" WIRING FROM ALL OTHER CIRCUITS. ",f'�'rf .r,t � DO NOT COMBINE INPUT OR ADDRESSABLE SIGNAL CABLES IN THE SAME _ CONDUIT WITH ANY OTHER CIRCUITS. • 5. ALL WIRING, INCLUDING SYSTEM GROUN)INC, MUST BE PER CURRENT # V Y { 4< U) NATIONAL ELECTRIC CODE. THIS ISA "PLEA" SYSTEM AS DEFINED BY n' z W '''''....;t:.‘'4".:w.' SECTION 760-41 THRU 760-71. .,..: 6. ALL CONTROL PANEL WIRING TO BE NEATLY HARNESSED, AND RUN AS 4tcv s ' " 0 HORIZONTAL OR VERTICAL ROUTES ONLY. ;' LEGEND W > cv 7. STRANDED WIRE (IF USED} MUST BE CONNECTED (AT BATH ENDS) WITH r. Q CLAMPING TYPE TERMINALS, CRIMP CONNECTORS, OR SPADE LUGS, ; r4 FIRE ALARM CONTROL PANEL MULTI-CD WALL MOUNT HORN/STROBE 8. MAINTAIN CONSISTENCY REGARDING CIRCUIT COLORS USED, FOR ALL DC : , O W CIRCUITS, USE THE FOLLOWING PAIR COLOR COMBINATIONS: RED/BLACK, ! I- I— p ORANGE/BLUE, WHITE/GREEN, YELLOW f BROWN, AND PINK/VIOLET, WITH NPS NOTIFICATION POWER SUPPLY MULTI-CD CEILING MOUNT HORN/STROBE Q THE FIRST (BRIGHTEST) COLOR POSITIVE, AND THE DARKER COLOR NEG- ATIVE. 4 <: ;: FIRE ALARM ANNUNCIATOR MULTI–CD WALL MOUNT STROBE FUR CURE COMP�CE Q z F- OP TIGARD 9. THE 120 VAC CONTROL PANEL POWER SOURCE MUST BE FROM A Approved: Q �, L1 AES RADIO COMMUNICATOR WALL MOUNT LOW FREQUENCY SOUNDER \+;; �t�l� PRINCIPAL BREAKER BOX, ON AN EXCLUSIVELY DEDICATED CIRCUIT, WITH OTC. W THE SWITCH POSITION CLEARLY LABELED PER THE WIRING DIAGRAM. Y j` Pcrn�it#: 0 THE CIRCUIT AND CONNECTIONS SHALL BE MECHANICALLY PROTECTED, �� ADDRESSABLE SMOKE DETECTOR SPRINKLE:: SWITCH (BY OTHERS} � 7 "vim ( � U Address: ."! THE DISCONNECT MEANS SHALL HAVE A RED MARKING AND BE — II ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL, LOCATION OF THE CIRCUIT ADDRESSABLE HEAT DETECTOR TS SPRINKLER TAMPER SWITCH (BY OTHERS) Suite# BREAKER SHALL BE PERMANENTLY IDENTIFIED AT THE CONTROL PANEL. (HT = HIGH TEMPERATURE 190' F) 3r ....ri!'',"'.-4 Date: 2f ss FIRE SMOKE DAMPER 10. INSTALLING FOREMAN WILL MAINTAIN ONE SET OF FIELD PRINTS, WITH ADDRESSABLE DUCT SMOKE DET, UP TO DATE RED LINE "AS BUILT" NOTATIONS, INDICATING ALL WIRE ® JUNCTION BOX ROUTES, EQUIPMENT LOCATION CHANGES, THE A.C. CIRCUIT # AND BREAKER ADDRESSABLE MANUAL PULL STA. OFFICE COPY BOX LOCATION, WORK PROGRESS, ETC. NAC-X = FIRE ALARM CONTROL PANEL NOTIFICATION CIRCUIT THESE FIELD DRAWINGS WILL BE DELIVERED TO NORTHWEST FIRE DRAWING INDEX ADDRESSABLE MONITOR MODULE SUPPRESSION, INC. WHEN THE INSTALLATION IS COMPLETE. SHEET# SHEET DESCRIPTION NPSX-X = NOTIFICATION POWER SUPPLY NOTIFICATION CIRCUIT VALIDITY O� PERMIT ................ 11. SMOKE DETECTOR HEADS ARE NOT TO BE INSTALLED PRIOR TO COMPLETION FA-1 TITLE SHEET, MATRIX, B.O.M. &SCOPE OF WORK DM DUAL ADDRESS MONITOR MODULE THE ISSUANCE OFA PERMIT OF INTERIOR SITE CLEANING BY ALL CONSTRUCTION TRADES. FA 2 1ST FLOOR PLAN & RISER DIAGRAM = CANDELA SETTING BASED ON CONSTRUCTION CC FA 3 FACP WIRING, DEVICE WIRING DETAILS &CALCULATIONS RM ADDRESSABLE RELAY MODULE D©CUMENTS AND OTHER 12. PRIOR TO LANDING FINAL TERMINATIONS AT THE FACP, AND AFTER ALL DATA SHALL NOT PREVENT DEVICES ARE INSTALLED, ALL SYSTEM WIRING MUST BE VERIFIED TO BE THE CODE OFFICIAL FROM ADDRESSABLE CONTROL MODULE O FREE OF SHORTS, OPENS, AND SHORTS TO GROUND. USE (MIN.) 20 MEG DEVICE ADDRESS (001 - 159) REQUIRING THE CORRECTION OHM SCALE FOR READING CIRCUIT SHORTS TO GROUND. RECORD ACTUAL (M)MODULE (D)DETECTOR OF ERRORS.OSSC 105.4 CIRCUIT RESISTANCE MEASUREMENTS NEAR THE RESPECTIVE EOLR's ONO LU THE WIRING DIAGRAMS OF THE FIELD PRINTS. • 13. INDELIBLY MARK ALL J-BOX COVERS WITH "FA" {MIN. 1" HIGH LETTERS). INPUTS AND ACTIONS 14. RESPONSIBLE INSTALLING JOURNEYMAN TO COMPLETE THE {NFPA 72) "RECORD �Pe � �e- 'G„ S OF COMPLETION" PRIOR TO SCHEDULING OF THE AHJ ACCEPTANCE TESTING. �� P`� �Qao ,� ,5 \- tI) s�G O4O J``' QpJFPJ G`)\QQ�Q.2`O�Pe• ��c)��JP Je,\<,0<<, Jr��,.> co c ,: . ���� B I LL O F MATERIALS "' OUTPUTS AND CONTROLS q• \'`Q�P�PO�y-fl4O0 •.., \O`'SQ c MANUFACTURER PART NUMBER EQUIPMENT DESCRIPTION QUANTITY CC r� NOTIFIER NFS-320 ADDRESSABLE FIRE ALARM CONTROL PANEL 1 m Y V I R E KEY OPERATE HORN/STROBE&STROBE SIGNALS •• •• •• •• X OPERATE WATERFLOW NOTIFICATION DEVICE ! A NOTIFIER UDACT-2 UNIVERSAL DIGITAL ALARM COMMIMUNCATOR 1 AS = 2 #16 AWG (MIN.), TWISTED PAIR "PLEA" SIGNAL UNE CIRCUIT (SLC) •U.• • •I • 'T 'CP&FAA ! • s • • i ! ! • ! ! AES XXXX RADIO COMMUNICATOR 1 NOTIFIER FDU-80 FIRE ALARM REMOTE ANNUNCIATOR 1 LU ~ A INDICATE DEVICE AT FACP&FAA • • • • • _ CC Q 'PLEA' L. _= - •ON DETECTORiii N.A. N.A. 12VOLT 26AH BATTERY 2 A = 2 #18 AWG (MIN.), PLEA INITIATING CIRCUIT - - - " - - Q NOTIFIER FSP 851 ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR 38 B = 2 #14 AWG (MIN.) "PLEA" STROBE (HORN/STROBE) CIRCUIT NOTIFIER FST 851 ADDRESSABLE HEAT DETECTOR 7 LLJ SHUTDOWN RESPECTIVE AIR HANDLING UNIT NOTIFIER B21 OLP 6"BASE FOR ADDRESSABLE DETECTORS 45 W C = 2 #12 AWG (MIN.) "PLEA" STROBE (HORN/STROBE) CIRCUIT E D 'M SI A TO OFF-SIT MONITORING ! •••••••• NOTIFIER NBG-12LX FIRE ALARM MANUAL PULL STATION 2 �� �iii���� Q NOTIFIER FMM-1 ADDRESSABLE MONITOR MODULE 1 F = 2 #14 AWG (MIN.) SHIELDED "PLEA" SPEAKER CIRCUIT NOTIFIER FDM-1 ADDRESSABLE DUAL MONITOR MODULE 1 I �. 'A •�� I L • • -S oil ••I G C NOTIFIER FRM-1 ADDRESSABLE RELAY MODULE 0 �_ D = 2#18 AWG (MIN.) SHIELDED "PLEA" DATA CIRCUIT NOTIFIER FCM-1 ADDRESSABLE CONTROL MODULE 0 I— FUNCTIONAL MATRIX SYSTEM SENSOR P2WK MULTI-CANDELA HORN/STROBE(WEATHERPROOF) 2 E = 2#14 (MIN,) "PLEA" 24VDC POWER SYSTEM SENSOR P2WL MULTI CANDELA HORN/STROBE (WALL MOUNT) 6 NOTES: SYSTEM SENSOR PC2WL MULTI CANDELA HORN/STROBE(CEILING MOUNT) 1 R = 2#14 (MIN.) "PLEA" RELEASING CIRCUIT 1 FACP SYSTEM TROUBLES INCLUDE,BUT ARE NOT LIMITED TO:AC POWER FAILURE,LOW BATTERY,OPEN CIRCUIT,GROUND SYSTEM SENSOR SWL FIRE ALARM STROBE (WALL MOUNT) 9 FAULT SIGNALING LINE CIRCUIT SHORT AND NOTIFICATION APPLIAN E CIRCUIT SH•RT. 2.SIGNALS SENT FROM THE FACP TO THE MONITORING FACILITY VI AES RADIO COMMUNICATOR• . 1 1 Design: D.LOCH Drawn: ACI Checked: S.DEFACCI Project No: 17-051 Date: 8/10/17 File: CWS-FA DWG DESIGNED BY: DAN LOCH FA- 1 SUPERVISING ELECTRICIAN STATE OF OREGON LICENSE NO: 2755LEA Sheet 1 of 3 W CJ Q - �w O f. W CL 0 CX O- CL' 0 W CC I— (1....1)(-) W C] O W Cn Q rT ts.1 W ce H W�W 5E CJ cr Q ce W O. Cf) Z 0 Q C..) O _ J CC O C, LEGEND Wz N aV) sw { FIRE ALARM CONTROL PANEL ►Z MULTI-CD WALL MOUNT HORN/STROBE c C rFIELD VERIFY SPRINKLER DEVICE LOCATIONS 1 .< >- VAULT (IF APPLICABLE) NPS NOTIFICATION POWER SUPPLY r IZI• MULTI-CD CEILING MOUNT HORN/STROBE m 00 M001 M002 M003 r» FS ® igi QD FIRE ALARM ANNUNCIATOR 1;11 MULTI-CD WALL MOUNT STROBE `- CONF. CONF. WOMENS MENS SPRINKLER b- w ROOM ROOM LOBBY LOBBY RR RR BATHROOM ROOM A- A A Q ( P 0 + DM �' AES RADIO COMMUNICATOR WALL MOUNT LOW FREQUENCY SOUNDER D038 0039 0040 M005 D041 0042 D044 0043 L z @--AS ADDRESSABLE SMOKE DETECTOR FS SPRINKLER WATERFLOW SWITCH (BY OTHERS) CONF. MECH CONF. BREAK OFFICE RECEPTION WORK/ OFFICE 0 ADDRESSABLE HEAT DETECTOR T SPRINKLER TAMPER SWITCH (BY OTHERS) 6a ROOM CLOSET ROOM CORRIDOR KITCHEN ROOM 109 110 HOTELING 113 CORRIDORC (HT = HIGH TEMPERATURE 190' F) {V Sb FIRE SMOKE DAMPER 1%**1 ` D037 D036 D035 ' 0034 D033 D032 0031 D030 D029 D028 D027 0ADDRESSABLE DUCT SMOKE DET. s L AS 0JUNCTION BOX O a 6 v OFFICE OFFICE OFFICE WORK MECH OFFICE OFFICE OFFICE OFFICE OFFICE ADDRESSABLE MANUAL PULL STA. o 2F 121 120 119 AREA CLOSET 118 CORRIDOR 117 116 CORRIDOR 115 114 NAC-X = FIRE ALARM CONTROL PANEL NOTIFICATION CIRCUIT t j o CO !I! . _ .. _ ,._ 0 0 0: 0 0 0.._ _ mADDRESSABLE MONITOR MODULE U (0 I A§ ,1s qj D015 D017 D018 0045 D019 D020 D021 D022 D023 D024 D025 D026 NPSX-X = NOTIFICATION POWER SUPPLY NOTIFICATION CIRCUIT °' o COCo ts g AS DM DUAL ADDRESS MONITOR MODULE to T FOUNTAIN if = CANDELA SETTING ai C umo7 WORK OFFICE OFFICE STORAGE OFFICE OFFICE OFFICE WORK WORK MECH o y=RM ADDRESSABLE RELAY MODULE AREA 122 123 ROOM 125 126 127 AREA SERVER AREA ROOM - - o v x c 0 0 Q, 0 0 0 0: 0 0 0 MXXX .1.:5- 6-i!; v tOj t: I B AS Eli ADDRESSABLE CONTROL MODULE tU a o 4 rn E k ', D016 D014 D012 D011 0010 0009 D008 M004 D007 D013 D006 DEVICE ADDRESS (001 - 159) 3 � NAC3-2 NAC3-1 Q (M)MODULE (D)DETECTOR P1 o C N C :e 1 75cd 75cd 1 "y co i n - € EOLR ,--� l _ _ ISA WB a FAA NAC2-9 NAC2-8 NAC2-7 NAC2-6 NAC2-5 NAC2-4 NAC2-3 NAC2-2 NAC2-1 z a) 30cd 15cd 15cd 15cd 3d 30cd 15cd 15cd 15cd LOBBY oil� o m t0 0 E 4 B LOW MECH/ELEC OFFICE CAD 101 WIRE KEY '. OD o s VOLTAGE ROOM 133 LIBRARY OFFICE ,n 11 NAC1-6 NAC1-5 NAC1-4 NAC1-3 NAC1-2 NAC1-1 AS Li ll 75cd 75cd 30cd 15cd 75cd 15cd ea 0' 0 " " It D001 D002 D003 D004 D005 AS = 2 #16 AWG (MIN.), TWISTED PAIR PLFA SIGNAL LINE CIRCUIT (SLC) ` Ii N SHEET FA-3.4- ®- AES FACP A = 2 #18 AWG (MIN.), "PLFA" INITIATING CIRCUIT si REGARDING SEE NO IL OCOMMUNICATION 2D E . " 71 ti :� ' PATH OPTIONS B = 2 #14 AWG (MIN.) PLFA STROBE (HORN/STROBE) CIRCUIT ! C = 2 #12 AWG (MIN.) "PLEA. STROBE (HORN/STROBE) CIRCUIT © 1 NFS-320 F = 2 #14 AWG (MIN.) SHIELDED "PLEA* SPEAKER CIRCUIT ---120VAC, 10A DEDICATED CKT, 0 = 2#18 AWG (MIN.) SHIELDED "PLFA" DATA CIRCUIT RISER DIAGRAM E = 2#14 (MIN.) "PLFA" 24wC POWER R = 2#14 (MIN.) 'PLEA" RELEASING CIRCUIT SCALE: N.T.S. 0 W Z U a CC L>j w QN m _ci) 01 Ci) L co o 2 0Q CO CD CD D J ID U A NOTES: g FIRE ALARM CIRCUIT RUNS SHALL CROSS LOBBY IN CONCEALED STRUCT OFFICE OFFICE OFFICE CEILING SPACE ON WEST SIDE OF BUILDING. CEILING 125 126 127 11'-5" 10'-6" 10'-6" DETECTORS D035, 0038 & D040 SHALL BE MOUNTED WITHIN A 1 3'-0" OF THE CEILING PEAK AND ALIGNED WITH LIGHT CEILING --1--=, mF1ELD VERIFY LOCATIONS On FIXTURES. WIRES FEEDING DEVICES ARE NOT TO CROSS BEAMS, 18'-1O" ALL SPRINKLER SWITCHES 4111ft AS A IMikik, -It' I SHALL RUN IN STRAIGHT LINES AND SHOULD BE AS HIDDEN AS epi ' r•"""1"1 ill ) D009 �DoO � TO VAULT TAMPERS (4C/16AWG M003 DI POSSIBLE. (IF APPLICABLE ( M002 7/111, NRfI I DEIECTCOR D030 SHALL BE MOUNTED ON THE DROPPED FIAT SLOPD037 - ,�` °�� 0036 " D011 i E M001 ► WOOD CEILING. ,� r \ MECH a s i_ f , ' E L d-r \ \ CL€ SET bomomp=a0s. E ‘ \ 105 12. 0 ., .K -'' COLI. 10� D012 129 �` CLOUD EOLR 102 M004, I EOLR p . NC 1 NAC2-9 - '�' ASs d NACI_6 41000 st >NrT rroommommo.rwwrm.w� 111‘ :. .. x o ,+ B 1 ::03:- 75dSERVER ! I CiI/I LEC rsfmN„ tER NAC2® ; . . . \ Cr Q46\.......' :EACH LIBRARY OFFICE � �^^ ""'.�, �.. E.w �. �OFFICE �.r.r" "w >�+( 28 OOMleCADD,0.1198, OFFICE 136 IOO?M 6-4°43:C 043 �! ' 005 �. 15Cd � _° a D%,, D034 -0 .rI° 4 122 Co1 1 1- � . � � � .,,� :. . .... �.:.. � O ( ; D014 t ' Qi 135 Q B - °°-'3' AS AS j, + .,\ / ,� W iii : ,�I �� A D039f NAC2-7 SLOPE IC T 00 x007 AS .. " D002 t; C` :�. 5d n� W tIE5 D004 D003 2-, d : ., "" :#' 15cd C!3 D006 NAC1-4 �.— _IFIW �QAS Ocd �O4 D041 B r.. 3 aLtTW .. BB`S , It-. ROOD ›-1 Er .�` ':.. 01 N, AtPS2-6 1 oZSQ .... VO! £AGE r D044 ,� �'�` :. 6 aD116 B 13 s taOI 3' 15cd Cr A MEN RRLI DO4�(4\ ( D001 "A' . M - 1 141 SUPP4LY8 �,�,°.' � �•i . � ,� � TO FACP0 10�A D045D021 D024pf, ----_,Low_—___ - '"" '� ¢r "�x8rt 1 ;d D �• WNAC1-3 NAC1-1 .�`f' 031 KITCHEN Aj B CL O ir 15d B NAC1-2 '' 108 D033D027II75dII _ 75cd D032 EPs�3p-2 `� O g;� y6 3 :F Arl► (` "!.. :. - �I:q;'""..,#MMN *4 f? G' 11 !.« '«:. ..,+1�. illa .NAG'S ( i I F E . t"11` 4 ..I ECHE D019: + :0A75cd LL.ir LOSET } 1 D030 I-- D015 E , 1 , Q L Z p �" C!D OFFICE : f "' .... � NPS2-.5r121 >tr"..„+www�E AS4111111hASilli AS AS li .OFF E EriIft 30�d0 0 f CJ f : .. - 30c11. 0E ` 1 QO2 D023 ^ D025 D026 D028 D029 NPS2-4 BREAK OFFICE If FICE E rE E OFFICE WOFK EOTELING RECEPTION OFFICE At ROOM k,D018 117 116 115 114 113 /112 110 109 107 D01 »""""" FSE/rIMNIMC.ri M>rMMMMMMMllflk' 1 1�3 a s ti?Et...;4....=' —,.... 1"""""....4 1: X1 .....G 1 , , dL: J If=41111111111011M =AM , 1=1=MINI __ 1ST FLOOR PLAN O 4' 8' 16' • a Design: D.LOCH SCALE: 1/8"=V-0" Drawn: ACI Checked: S.DEFACCI Project No: 17-XXX Date: 8/10/17 File: CWS-FA DWG DESIGNED BY: s':;;c:) __ erl(_// -2 DAN LOCH FA SUPERVISING ELECTRICIAN STATE OF OREGON LICENSE NO: 2755LEA Sheet 2 of 3 DETECTOR, PULL STATION, MONITOR MODULE WIRING SIC TO NEXT SNC TO DEICE SLC FROM NEXT PREVIOUS DEICE DEVICE 1.11101FMM-1 0 2 1 @'''''L" 110ii T11+-(-)J. (+) (-� lei T9 A+ T2 +) ii T3 03 � TS A- T4 EOL47K 176-- `-(-) 1 T7 B- B21OLP (+) T6 B+ T5 SLC FROM ' PREVIOUS - DETECTOR BASE DRY CONTACT DE SWITCH ADDRESSABLE DETECTOR WIRING MONITOR MODULE WIRING 1 Fra.• wlw�r r.��.r�.'i"w�E.r>•.Yiw�Y .�..r:iF.C�rtr.�.+k4�Osi.�(•a Srrer.�lirin ProjectName:�pCW-.r-wu-r.a�TAYr�waa .-waP�. ImRLsrr:L-rT7ItN-.1�aU •PaS� �wR- • *r (Jw vIcE Circuit ID:Project Number: NAC3 r>_r.r rla- - -S r. 1"ar.�`rr.�. <a r.r' .�wrl�rri w. 'r.� rias ia.r >a.a aS S- - .ar'.aaaS SLC TO TOTAL >- NEXX E 4 SLC TO QTY PART# DESCRIPTION CURRENT CURRENT on DEVI I SIC FROM NEXT Peripheral Devices "" PREVIOUSDEVICE EQUIPMENT MOUNTING REQUIREMENTS 4:.0....0,. P2WL HC3R1+ItSTRC}BE, 15cd, Wall,White t},4544J13 0:00000 W SPRINKLER T11 FDM-1 0 P2WL- HORNI STROBE, 75cd,Wall,White 0.12100 0:00000 ~ SWITCH . T1 (-) 2 P2WK HORN/STROBE(weatherproof), 75cd,Wall,White 0.15700 0.31400 a o (-) 0(+� 47K EOLR. T10 T2 ' (+) FIRE ALARM CONTROL PANEL TOP OF ENCLOSURE AT 64" ABOVE FINISHED FLOOR (A.F.F.) 0 SWL STROBE, 15cd,Wall,White 0.04300 0:00000 0 1 2 (-) T9 H- z NBG-12LX (+) Lii, T3 STROBE, HORN/STROBE 4" SQ. X MINIMUM 1 1/2" DEEP BOX, 4.0" OCTAGONAL BOX, 0 SWL STROBE,38cd,Wall,White 9.v630o 0.00000 U T8 H+ 0 0,00000 0 00000 1 ADDRESSABLE EOLR7--------..... ( + T4 DOUBLE GANG OR SINGLE GANG BOX r PULL STATION 47K -) l a T7 L- T5 SLC (WALL MOUNT CENTER OF BOX 90" (A.F.F.)) Subtotal [I] 0114010 $q 11 g rr�wr ■ SPRINKLER (+) T6 L+ PREVIOUS (WEATHERPROOF DEVICES INCLUDE SURFACE BACKBOX) Circuit Length(Feed) '140 I� r- .rsrs■ DICE Wire AWG # 14 SWITCH .�..,� s MANUAL PULL STATION SINGLE GANG BOX, 48" TO CENTER (A.F,F.) 'Terminal Block(TB#) or Circuit ID Maximum Current Available-(amps):[ 4l<00 ," .. 1 MANUAL PULL STATION WIRING FMM-1, FDM-1, FCM-1, FRM-1 4" SQ. X MINIMUM 2 1/8" DEEP BOX (Per NEC Table 8 Conductor Properties:-eolxper, Solid, Un+c ateci 75Ct 167F)chr llcFT.; mm.3.07 O a 03 6 6i DUAL ADDRESS MODULE WIRING " " {j(Wiry:Len thx.cftm}!'l(f00]�e2jResistan+ce (R) �-- 6pi lei 0 ,Pi ci N 14§ SMOKE & HEAT DET. (B21OLP) 4" SQ. X 2 1/8" DEEP BOX, 3.5 OR 4.0 OCTAGONAL BOX, ._ [I) x [R1=[VD] (No greater than 4.4v)Volts Dropped: 0,270 til U co II A: OR SINGLE GANG BOX . (Per NFPA'72 201310.3.5(1):-85%of 24VDC)Calculated Supply Voltage: 20,4 43 +) o 4 E ts 11 (o (No greater than 21%)Calculated Voltage Drop°la: 1.32% '- � u• �g (16-33VDC operating range; per UL 1971)Calculated End of Line Voltage: 2'0.130 �y c o as 1 CalculatedMaximumAllowable Circuit length (Feet): 2222 i� v 8 c I X w- sI Re, 'VOLTA E DROP CALCULATION (LUMP SUM) •ti -c o N 5 a.61 .srlr�lsa,>•-r-Y"rwwt#..-r.faa�a�-rrl-rr�...l-aa-a--rra�.A aall�r;sa.I�l�lNlw FIRE ALARM CONTROL PANEL ANNUNCIATOR, IPGSM COMMUNICATOR WIRING ProjectNarrae:cWS - �' ( h - ti Circuit ID: > v ISS ` �ww�rra+wll r'r a���wa..wrw"aa.ae,r,r r�.�w•.r!I:Iw.+awl- R7"Ilrra�-a.awl"ri..s airs.l.rw.aaMla+111!>r■�.zsr#a.t-aa a�taaww.+a -LI Project Number: NAC2 Z o I E s S; rr�awMlrr`a wra r.rrrra�rA►wa.rr..I wl Yf ralPrr a.ww iP l.irrr.rwr,Y.wFrr a.Yr.:1�rrw.r-a�rr ra•rMrr aMI.' rr�a-w"1r:a:rw 4ti) EIS TOTAL O m (0 >s QTY 'PART.# DESCRIPTION CURRENT CURRENT o A Peripheral Devices - a 6 1 1 P2WL HORN/STROBE,15cd,Wall,White 0:05400 0.05400 k.1 In $' - - NAC-4 (SPARE) 0 &A 0 P2WL HORNISTROBE, 75cd,Wall,White 0.12100 0.00000 NAC-3 HORN/STROBE CKT HORN/STROBE STROBE HORN/STROBE >0 P2WK HORN/STROBE(weatherproof),75cd,Wall,White 0.15700 0.00009 Ell + + (- + + + + 5... SWL STROBE 15cd,Wall white 9.04300 0.21500 1 } ( (_ , s ti l2 --�--�- NAC-2 HORN/STROBE CKT � 3 SIM- STR€�BE, 30od.wall,White... 0,06300 0,18900 I 4 ` : , 0 PC2WL HORNiSTROBE1,75cd,Ceiling,White 0.14300 0.00000 ..a W . III NAG-1 HORN STROBE CKT Subttatal (1): 0,..... +)_ .. L 1 EOLR _ Circuit Length Fessoctsp --.r 0 s. VVire AVVG`: r.>...a Terminal Block(TB#)or.CircuitID Maximum Current Available(amps):f 9,00 � .-•Pr-.a■ (Per NEC Table 8 Conductor Properties Copper,Solid, Uncoated 75C/167F)al mlkFT:■ 3.07 ([(Wire Length x ohm)11000]x 2) Resistance [R : 1.535 [I)x [R]:#[ 'O) (No greaterthan 4.4v)Volts Dropped: 0.703 (Per NFPA 72 2013 10.3.5(1): 85%of 24VDC)Calculated Supply Voltage: 20.4 ( U) s.FDU-80 ANNUNCIATOR . (No greater than 21%)Calculated Voltage Drop lo: 3 45% z W -LEAVE SHIELDS FLOATING (16-33VDC operating range,per UL 1971).Calculated End of.Line Voltage: 19.697 5 Calculated Maximum Allowable Circuit Length (Feet): 1523 JCrui I [ I - 0 .1 .„‘ I SWI-1 ON _ SWI-3 ON cn . VOLTAGE DROP CALCULATION (LUMP SUM) OC 1 cL 819(961900 0000 SWI-3 ON Reil 00 SW1-4 OFF .-.s-r.-.r�..=a.-r.srr-rr-rr-wr-.r-rw-as.-�r-as-r.-r= L.0 0 1 Project Nance:.CWS Circuit ID:: �, m�'''l I I ++Z 1 I ++ SW1-5 OFF wa �..-wasww.fry.: rra�.....rwla.rAwa.wa.w�.a�-wasw.raww+rwri.Yrwrw+. .•.w.wt�;..�...r-ar _ 0 D'NaNNIVo m+7r!1mm I"rojeCt [�[a IMI:e :. F'.A.C. " . CC g;A-AAr1 bDDD SW1-6 OFF . al-rrr�.aerr:.ate-w:aa wa...lwar..•r.w. as rw.r-r ate- sw.wA--ww>• C `^ 0 Q `dc`a�5d`o TOTAL-- Q 0 - c�c�c��z -r -PA ' ,, zoczcZn encnc`dr+(ODs+ ON -�--+N a m� n QTY PART#: DESCRIPTION CURRENT CURRENT co _ ,-4--- �.�. .. --1 N-A D O D D E 11 SIC OUT TO ADDRESSABLE DEVICES i z p �. v = `'w SW1 1 2 3 4 5 6 Peripheral Devices i ♦ v / 2 P2WL HORN/STROBE, 1Scd,Wall,White 0,05400 0,10800 D W ( 1 2 P2WL HORN/STROBE, 75cd,Wall,White 0,12100. 0.24200Q , 2!;1•44,., P2WK` HORN/STROBE(weatherproof), 75cd,Wall,White 0.15700 0.00000 IIPIIIIIIIIIIIIIMIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIMIIIIIIIIIIIIIIIIIIIIIIIIIIIII :miog svvL STROBE, 15cd,Wall,White 0.04300 0.00000 II SWL STROBE, 30cd,Wall,White 0.06300 0,06300 ,-.1:::. i:,,,.;,- PC2WLHORN/STROBE,75cd, Ceiling,White 0.14300 0:14300 ®®®® Subtotal [1]: 0: 56011<` 0 ZONE CODER(- O 0 ®®®® ®®®®®® 0 ®®®®®® OQOOD Y T613 8+ A+ B- A- Carcaa:lt LenC tla(Feet) 1:i:!. .:;!.,1151:1:-::1: :.-1-i.,:- J8 Feet): 0 J8 TB1O + - + - + - + - + - B11 TX RX REF TX RX REF 1 SLC s.-mal-acs TB9 1 REC XMIT EIA-485 NUP PORT USB A USB B wire AWG 14 NAG#1 w t� ( PRINTER I PC/CRT J1 J2 J3 �.r.r.ra■a�. ® A- F EIA 485 ACS • ('l rf>� >� TERM. TB12 Terminal Block(TB#) or Circuit ID Maximum Current Available(amps):[ c1<00 } NAC-1 ® A+ �� N� N W (CONTACT ID OUTPUT) ® B- • GNDFAULT , o ® a„s (Per NEC Table 8 Conductor Properties Copper,Solid, Uncoated 750114 7F)OI'>a11I1CFT:■ 3,07 �,... .. ,..�,,.. ,® B+ =ENABLE • I ZL - ._a>t 35MIMI w a a _DISABLE ([(Ware Length x ohm)f 1000] x 2)Resistance [Ry: 1,535 d �_ TER{IDM R2 KEYBOARD DISPLAY A- ,...w.. ....__..w.._v.__ _._.�v...�._ ._., ..u.wD... __.,. �...-_-.- _-. - _��..��.-..�.�...�.�W.--,-- -. ___...._ -W. 1 x [R] IVO)(No reatc.rthan 4.4v Volts Dropped: [1.853 I 1 + a I [] ( ] 9 ) pP NAC-2A+ TB8 ss (Per NEPA 72 2013 10,3.5(1): 85�7o of 24VDC)Calculated Supply`Voltage: 20.4 _- - B- NAG#2 I J6 ,t B+ J3 J4 . (No greater than 21%)Calculated Voltage Drop% 4,18% -- PRIMARY SECONDARY USB (16-33VDC operating range,per UL 1971) Calculated End of Line Voltage: 19.547 ® +24V Calculated Maximum Allowable Circuit Length(Feet): 1255 ® cta + +24V (+) ® A- COMto _RELAY DRIVE CD NAC-3 v ® g+ NAC#3 TB7 ® -+5v COMMON®�-(-) t -� Cl) �2 3 NOTIFIER N FS-320 INPUT 5 AES RADIO oc o - CS:, A 1 0 INPUT 4 �: . COMMUNICATOR NFS-320 BATTERY CALCULATIONS (FACP) w =� 1= NAC-4 0 - i �,�.• .. B- TB6 (FACP) ® (+) } STANDBY CURRENT (AMPS) j ,.,...._ EIA-485+ , TB1 - ® B. NAC#4 3 s DESCRIPTION CURRENT QTY TOTAL OD W U INPUT 3 EIA-485-@ (-) - - ® "� ' MAIN CIRCUIT BOARD ' 0.2500 1 0.2500 0 oe (D000 `"',...--- / NAC CKTS IN USE 0.0350 3 0.1050 120 VAC, 1d1A DEDICATED CIRCUIT ® INPUT 2 Qi.. . .-.W CC - C� 1 NEU j REF KDM-R2 DISPLAY 0• .1000 1 0.1000 I 0 SLC LOOP 0.2000 1 0.2000 Q - - ® 00INPUT 1 SW1 I EARTH GND U TBs ONO �� `V O FDU-80 ANNUNCIATOR 0.0643 1 0.0643 UJ _ ___I ® C € UDACT-2 COMMUNICATOR 0.0520 1 0.0520 ® NC = 0 0 C) 0 ��,/ SELEOPTICCT N ON TOTAL STANDBY(AMPS) 0.7713 U- a_ w ® NOS 3 DDDR ® NC j (m.„....„, SWITCH 1 2£3 4 ALARM CURRENT (AMPS) `� 0 DESCRIPTION QTY TOTAL L.. ® , # DRAW MAIN 0.2500 1 0.2500 ® NO u, I 1 a I UaACT-2 NAC CKTSIISN USE EARD 0.0350 3 0.1050 1 ALARM TROUBLE n °i'S" ""+" J7J I SW5 SW6 SW7 J5 J6 C NC NO C NC NO R + + OOOOOOOQOOOOOOOOg000 { n®®®®®® TBa IW I I F ;Q; OO o000000000a00000a000 0o an € / KDM-R2 DISPLAY 0.1000 1 0.1000 I�vJ / SLC LOOP 0.2000 1 0.2000 FDU-80 ANNUNCIATOR 0.0643 1 0.0643 UDACT-2 COMMUNICATOR 0.0870 1 0.0870 NAC-1 0.5560 NFS-320 CONTROL PANEL CABINET DIMENSIONS: 18.12"W x 18.12"H x 5.81"D NAC-2 0.4580 NAC-3 0.3140 NAC-4(SPARE) 0.0000 :::. .. TOTAL ALARM (AMPS) 2,1343 BATTERY CALCULATION TOTAL Design: D.LOCH 12V, 26AH M + L 12V, 26AH STANDBY BY CURRENT 0.7713 Amps x 24 HRS 18.51 AH Drown: ACI BATTERY BATTERY ALARM CURRENT 2,1343 Amps x .084 0.18 AH Checked: S.DEFACCI SUB TOTAL 18.69 AH Project No: 17-XXX TOTAL AMP HOURS REQUIRED(AFTER 20% DERATE) 22.43 AH TOTAL AMP HOURS SUPPLIED 26.00 AH Date: 8/10/17 File: CWS-FA.DWG DESIGNED BY: DAN LOCH ZFA-3 SUPERVISING ELECTRICIAN STATE OF OREGON LICENSE NO: 2755LEA Sheet 3 of 3