Loading...
Plans (2) FPS20 7 - 04416 ---- --... ------ . • • • 1 2 3 4 5 a 6 • 7 8 • .I gir!(!+E'iltl t lleri l�l+'Il�t�#.3 1111,,„ ,,, s„i, ,r„,„,►,4 ,itw , i' S ______________J _________, • • 1 . REG IVSD 1O1'.'CLEAN WATER S ,( MAR. !.' a 2011- 4- CITY O TI: ARD A `�' BUILDING DIVISION • DURHAM O & M BUILDING . . la ,c:) . L-_?_•..- It f3t\0 ik • d------) .. . . (.. V) 0 �'f lit/ f j FIRE ALARM sysTEM MODIFICATIoNI / IBJ ,. . . . il ,. 4,01) 1 __ . _ Ctr . , ---.--- [If*. '-' t''I ' I dirk. 1 iii..' r711. Ils; t.-:__ -ii ' 'i"„,,,„., \ 1: % c=1 �� bio• �` int rl . / • •• ii,. Q 16060 SW 85TH AVEI 0&M BUILDING '.� • . / . ,411111k:\,,( ''i`,1� �� � I ,''. :" z \lure' iiimmr , . Aril" I . 6. TIGARD OR 97224 I DURHAM SITE PLANI. �i ,o o �� C SCALE: 1 n=50Q'-Qn 0if - y CO ao N i i to 0 w 1 i) \ ji.,_ Q) a) 0 3 E A-'6 i ++ O c- 0 I 1U .„..�,---- w cn to ti is til ° t"Y, iii aoxc lb Fi_• ° " pli • - o QC ! .>: Ni g ;, Cl _ IliT- 0n ; t 0.• ill .•• p m (0 32 ov o 1!! D .-• 2 VOLTAGE DROP CALCULATIONS SCOPE OF WORK BILL OF MATERIAL j 11 Point to Point Method End of Line Method Load Centering Method MODIFY THE EXISTING NOTIFIER ADDRESSABLE FIRE ALARM s : Project Name Clean Water Services O&M Bldg Remodel CIRCUIT IS WITHIN LIMITS - CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS DESCRIPTION MANUFACTURER PART# CITY. C`'� a Date 11/4,161 SYSTEM PER THE REMODEL OF THE SHOP AREA OF THE CLEAN �/ lir Circuit Number NAC4(Reused/Relocated from FCPS1) End of Line and Load Centering Methods use only the wire guage for the first device to source WATER SERVICES DURHAM SITE O&M BUILDING. 8AMP NOTIFICATION POWER SUPPLY W/SYNC NOTIFIER FCPS-2458 1 mos1 Area covered Shop&New Office Nominal System Voltage 20.4 Standard Wire Resistance in Ohms per 1000 feet. 12VOLT, 8 AH BATTERY N A/ N/A 2 • Minimum Deuce Voltage 16 ,8=7.77 16=4.89 14=3.07 12=1.98 10=1.24 ADD ONE NOTIFICATION POWER SUPPLY, RELOCATE SEVERAL ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR NOTIFIER FSP-851 5 ® J Total Circuit Current 0.724 Wire Ohm's 18-14 Awg=Solid Conductors 12-10 Awg=Stranded Conductors W Gauge Per 1000 Notes: EXISTING DEVICES AND ADD NEW DEVICES AS NECESSARY TO SMOKE DETECTOR BASE NOTIFIER B210LP 5 Distance from source to 1st deice 110 14 3.07 Wire resistance is doubled in the calculations for two wires(Positive and Negative) MEET CURRENT OSSC AND NFPA 72. MULTI-CD HORN/STROBE, WALL MOUNT, RED NOTIFIER P2R 3 1)1Z0 Wire Gauge for balance of circuit 14 3.07 The roltage calculated to the last deuce in any method must not be lower than Cl Enter current in amps. Distance the manufactures listed minimum operating voltage(IE:rated_operating roltage 1632 VDC). MULTI-CD STROBE, WALL MOUNT, RED NOTIFIER SR 1 ® CO CO .150= 150 ma from Voltage Alternate Calculations U W Deuce Deice previous At Drop from Percent • End of Line Method Load Centering Method CC Number Current device Device source Drop Totals Voltage Totals Voltage [V Device 1 0.137 110 19.91 0.489 2.40% Current Distance Drop Current Distance Drop cc 0 LL1 Deuce 2 0.176 45 19.75 0.651 . 3.19% 0.724 360 1.600 0.724 360 0.800 LU Z co Q rn E Device 3. 0.13755 19.61 0.790 3.87% End of Line Voltage 18.80 End of Line Voltage 19.60 GO D .- 2 Z Deuce 4 0.137 65 19.50 0.899 4.41% _ Percent Drop 7.84% Percent Drop 3-92°,° BATTERY CALCULATIONS 0 Device 5 0.137 85 19.43 0.971 4.76% _ W oo uj END 19.43 0.971 4.76% Deuce Manufacturer System Sensor EQUIPMENT MOUNTING REQUIREMENTS Q CO Q u) o END 19.43 0.971 4.76% ' Current Current FCPS 3 (FCPS-2458) END 19.43 0.971 4.76% @Rated @Rated FIRE ALARM CONTROL PANEL 66" TO TOPA.F.F. . 120 VAC TO ENTER ON LEFT SIDE OF ENCLOSURE 0 8 cc END 19.43 0.971 4.76% Model# 'Candela Voltage Model# 'Candela Voltage ¢ • • END 19.43 0.971 4.76% S(W,R)(C)Multi-Cd 15 0.066 P2(W,R)(C)-Multi-Cd 15 0.079 COMPONENT QTY. Normal (A) Alarm (A) Normal Total Alarm Total LCD ANNUNCIATOR 66 TO TOP A.F.F. . Z T C3 END 19.43 0.971 4.76% Strobe 1575 0.077 Hom/strobe 1575 0.090 (*) HORN STROBE, STROBE WALL MOUNT 80" TO BOTTOM (A.F.F.), 4" SQ. X 1 1/2" D. BOX " n O ~ END 19.43 0.971 4.76% Wall,Ceiling or WP 30 0.094 Wall,Ceiling or WP 30 0.107 Main Circuit Board1 0.06500 0.14500 0.06500 0.14500 MANUAL PULL STATION 44" TO CENTER (A.F,F,), 1 GANG M.R. ON (MIN.) 1 1/2" D. BOX J - • END 19.43 0.971 4.76/° 75 0.158 75 0.176 NAC4 (Relocated) 1 0.00000 0.72400 0.00000 0.72400 Q • END 19A3 0.971 4.76% 95 0.181 95 0.194 ADDRESSABLE SMOKE DETECTOR 3.0 MUD RING ON 4" SQ. X 1 1/2" D. BOX (MIN.) CD NAC6 1 0.00000 0.61000 0.00000 0.61000 / " ) ) = END 19.43 0.971 4.76% 110 0.202 i10 0.212 CONVENTIONAL HEAT DETECTOR 3.0 MUD RING ON 4" SQ. X 1 1 2 D. BOX MIN. END 19.43 0.971 4.76% 115 0.210 115 0.218 SPARE 1 0.00000 0.00000 0.00000 0.00000 RIM-1, FRM-1, FM-1, FDM-1 4" SQ. X 2 1/8" DEEP (MIN.) BACKBOX D END 19.43 0.971 4.76% S(W,R)(C)H-Hi Cd 135 0.228 Existing Devices- SPARE 1 0.00000 0.00000 0.00000 0.00000 CI END ' 19.43 0.971 4.76% Strobe 150 0.246 P1224MC Multi-Cd 75 0.137 AUX PWf 1 0.00000 0.00000 0.00000 0.00000 . END _ 19.43 0.971 4.76% Wall,Ceiling or WP 177 0.281 Horn/Strobe 110 0.170 END 19.43 0.971 4.76% 185 0.286 PC241575 Gig FUS 1575 0.079 Totals 0.06500 1.47900 • Totals 0.724 360 End of Line Voltage 19.43 Battery Calculation Hrs Current AH Safety Batt Req (AH) • F Point to Point Method End of Line Method Load Centering Method Normal 24 0.06500 1.56000 DRAWING INDEX o Project Name Clean Water Services O&M Bldg Remodel CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS Alarm 5 min. 0.0833 1.47900 0.12320 Date 11/4/161 Circuit Number NAC6(New Circuit) End of Line and Load Centering Methods use only the wire guage for the first device to source Total Additional Amp/Hours 1.68320 1.2000 2.01984 FA-1 TITLE SHEET, B.O.M., CALCULATIONSQ Area Covered Shop, Lockers, RR Battery Supplied 2 1 8.00' . • C.) • Nominal System Voltage 20.4 Standard Wire Resistance in Ohms per 1000 feet. FA-2 AREA OF WORK FLOOR PLAN .�r, Minimum Device Voltage 16 18=7.77 16=4.89 14=3.07 12=1.98 10=1.24 �.+ Or TIGAItD LL O Total Circuit Current 0.610 Wire Ohm's 18-14 Awg=Solid Conductors 12-10 Awg=Stranded Conductors (*)Current Values from FCPS-24S Series Manual- Rev G4, Page 40 FA-3 DEVICE WRING DETAILS REVIEWED FOR CO COMPLIANCE E m Gauge Per 1000 Notes: Distance from source to lstdevice 1 150 14 3.07 Wire resistance is doubled in the calculations for two wires(Positive and Negative) OLLJ 06 Wire Gauge for balance of circuit 14 3.07 The voltage calculated to the last device in any method must not be lower than 1 OTC: G l"fes' ! 't -( CI-- e W . Enter current in amps. Distance . the manufactures listed minimum operating voltage(IE: rated operating roltage 16-32 VDC). - I I co , = z .150= 150 ma from Voltage Alternate Calculations Permit t 2i /1/'_5 J W Deuce Deice previous At Drop from Percent End of Line Method Load Centering Method L�� (_.�-[t� j I- W Q Number Current device )((`. Device source Drop Totals . Voltage Totals Voltage Address: ' Cr)Deuce 1 0.170 150 19.84 0.562 2.75% Current Distance Drop Current Distance Drop [ ('w -� J I- - ›-. I- Deuce 2 0.137 60 19.68 0.724 3.55% 0.610 325 1.217 0.610 325 0.609 Suite - ' Cl) Device 3 0.079 30 19.62 0.780 3.82% End of Line Voltage 19.18 End of Line Voltage 19.79 .- Dates -A-1lt� l By:Deuce 4 0.079 10 19.61 0.793 3.89% Percent Drop 5.97% Percent Drop 2.98% ` J • Deuce 5 0.079 35 19.58 0.825 4.04% a CC Device 6 0.066 40 19.56 0.841 4.12% Device Manufacturer 'System Sensor • Q END 19.56 0.641 4.12% Current Current G END 19.56 0.841 4.12% @Rated QRated OFFICE r Q � U END 19 .56 0.841 4.12% Model# 'Candela Voltage Model# Candela Voltage OFFICE COPY W END r 19.56 0.841 4.12% S(W,R)(C)Multi-Cd 15 0.066 P2(W,R)(C)-Multi-Cd 15 0.079 CC . • END 19.56 0.841 4.12% 'Strobe 1575 0.077 Horn/Strobe 1575 0.090 LLL END 19.56 0.841 4.12% Wall,Ceiling or WP 30 0.094 Wall,Ceiling or WP 30 0.107 • END 19.56 0.841 4.12% 75 0.158 75 0.176 - END 19.56 0.841 4.12% 95 0.181 95 0.194 r • END 19.56 0.841 4.12% 110 0.202 110 0.212 END 19.56 0.841 4.12% 115 0.210 115 0.218 Design: D.LOCH END 19.56 0.841 4.12% S(W,R)(C)H-Hi Cd 135 0.228 Existing Deices- END 19.56 0.841 4.12% Strobe 150 0.246 P1224MC Multi-Cd 75 0.137 Drawl,: ' M.SCHAENZER END 19.56 0.841 4.12% Wall,Ceiling or WP 177 0.281 Horn/Strobe 110 0.170 - END 19.56 0.841 4.12% 185 0.286 PC241575 Clg H/S 1575 0.079 •-1 Totals 0.610 325 End of Line Voltage 19.56 1 s Checked: S.DEFACCI Project No: 16070 Date: 11/4/16 H , ) .. . . File: 16070-FA.DWG • Y > DESIGNED BY: DAN LOCH FA- 1 SUPERVISING ELECTRICIAN , STATE OF OREGON LICENSE NO: 2755LEA ,SHEET 1 OF 3