Plans (3) E LC2O 17 - 00875 ..:_ 4, OFFICE COPY RECEIV ED JITNEY SECTION 011000 - GENERAL CONDITIONS AND REQUIREMENTS 16. REFER TO MECHANICAL, FIRE PROT CTION, PLUMBING 2. CONNECT NEW BUILDING STANDARD PACKAGED ROOF TOP 1.1 ALLOWANCES AND UNIT PRICES 1. ALL WIRE SIZE NUMBER 8 AWG AND SMALLER FOR USE NOV 2 7 ZC17 SHOP DRAWINGS AND CONSTRUCTION DRAWINGS FOR UNITS TO NEAREST EXISTING BUILDING HEATING CIRCUIT IN INTERIOR DRY LOCATIONS SHALL BE TYPE THWN ARCHITECTS, INC. 1.1 GENERAL CONDITIONS EXACT LOCATIONS OF ALL EQUIP ENT INCLUDING WITH LOAD CAPACITY NOT TO EXCEED LOCAL CODE 1• INCLUDE IN BIO AN ALLOWANCE PER 2000 SQ, FT. OF THERMOPLASTIC 600 VOLT INSULATED COPPER CITY OF TIGARD QUANTITIES, SIZES, TYPES AND VOLTAGEI RATINGS PRIOR LIMITATIONS FOR CONTINUOUS BRANCH CIRCUITS. CONTRACT AREA THE FOLLOWING ADDITIONAL LIFE SAFETY CONDUCTORS. ' FEEDERS AND- POWER WIRING NUMBER 6BUI�DING DIV'SIO d 700 Commerce Drive I Suite 350 DEVICES, INCLUDING INSTALLATION AND ALL CONDUIT AND Oak Brook,IL 60523 I USA 1. THE WORD PROVIDE' MEANS "THE CONTRACTOR SHALL TO EQUIPMENT ORDERS AND INSTALLATION. PROVIDE NEW BRANCH CIRCUITS WITH NEW CIRCUITAWG AND LARGER SHALL BE: TYPE THWN 600 VOLT T: 630.571.1118 I F: 630.571.0518 WIRE, FOR ADDITIONAL DEVICES AS MAY BE REQUIRED BY FURNISH AND INSTALL° THE ABBREVIATION 'THE BREAKER (TO MATCH EXISTING) AS- REQUIRED. MAKE ALLINSULATED COPPER. WIRE WHICH IS INSTALLED IN whimsy-architects.com E.C."MEANS "THE ELECTRICAL CONTRACTOR.' 17. RACEWAYS, CONDUIT AND BOXES LOCATED IN PLENUM NECESSARY CIRCUITRY MODIFICATIONS AS REQUIRED AND THE REVIEW OF THE AUTHORITY HAVING JURISDICTION: RACEWAY IN MOIST OR DAMP'..:LOCATIONS OR IN HIGH CEILINGS SHALL BE PLENUM APPROVED. EXISTING WORK a. EUP-1 EXIT SIGN FIXTURES SHALL VERIFY EXACT CIRCUIT REQUIREMENTS IN THETEMPERATURE CONDITIONS SUCH AS BOILER ROOMS OR IL.CORPORATE LIC. 184 o015so 2. PROVIDE ALL LABOR AND MATERIALS NECESSARY FOR A SHALL BE REVISED AS REQUIRED TO CONFORM TO THIS b. EUP-2 EMERGENCY LIGHTING FIXTURES COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM REQUIREMENT. FIELD. c. EUP-3 SMOKE DETECTORS CONNECTIONS TO HEATING EQUIPMENT SHALL BE AND INSTALLATION. 3. ALL BUILDING STANDARD PACKAGED ROOF TOP UNITS A d. EUP-4 HEAT DETECTORS XHHW/XHHW2, 600 VOLT INSULATED COPPER 18. WHERE THE INSTALLATION OF NEW CONSTRUCTION SHALL BE APPROVED BY THE AUTHORITY HAVING PROVIDE A UNIT PRICE FOR EACH DEVICE FOR QUANTITY CONDUCTORS. NO WIRE SMALLER THAN NUMBER 12 AWG 3. MATERIALS AND INSTALLATION SHALL COMPLY WITH SURFACES OR MATERIALS RENDERS AN EXISTINGSHALL BE USED FOR LIGHTING OR POWER CIRCUITRY. ALL BUILDING STANDARDS AND MASTER ELECTRICAL JUNCTION BOX, PULL BOX OR OTHER ELECTRICAL JURISDICTION AND SHALL HAVE A BUILT-IN OR EXTERNAL ADJUSTMENT, WIRE AND CABLE SHALL BE COPPER. WIRE NO. 12 AWG SE "IN-SIGHT" DISCONNECT SWITCH AT UNIT. E.C. SHALL MAY BE SOLID OR STRANDED,:.WIRE NO. 10 AWG AND SPECIFICATIONS INCLUDING ALL CODES, LAWS, AND EQUIPMENT INACCESSIBLE, RELOCATE THESE ITEMS TO 2. INCLUDE IN BID ELECTRICAL UNIT PRICES (EUP- 1 THRU HARD WIRE DIRECT ALL VAV LARGER SHALL BE STRANDED. STRANDED WIRE SHALL Environmental systems Design,Inc. ORDINANCES OF FEDERAL, STATE, AND LOCAL GOVERNING MAINTAIN THE REQUIRED ACCESSIBILITY. BOXES WITH FLEXIBLE EUP-4) TO PROVIDE ADDITIONALIFE SAFETY DEVICES L BODIES HAVING JURISDICTION. PLENUM APPROVED ELECTRICAL CONNECTION TO MATCH WITHIN FINISHED CEILING SYSTEMS, INCLUDING ALL NOT TERMINATE ON WALL SWITCHES OR RECEPTACLES. 175 West Jackson Blvd.Suite 1400 EXISTING BUILDING STANDARD INSTALLATION. USE SPADE CONNECTORS OR PIGTAILS WITH PIGTAIL SOLID Chicago,Illinois 60604 19. PROVIDE OUTLET/JUNCTION BOX EXTENSION RINGS AS CONDUIT AND WIRE, FOR EACH TYPE OF DEVICE AS 312 372 1200 fax 312 372 1222 4. ALL MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR REQUIRED FOR EXISTING WALL OR CEILING OUTLETS WIRE TERMINATIONS ON LINE TERMINAL SCREWS. USE OF www.esdglobal.com LABELED BY UL, ETA, CSA, OR ANOTHER CITY COOS 4. PROVIDE NEW BUILDING STANDARD USER DISCONNECT NOTED ABOVE. THE UNIT PRICE SHALL INCLUDE ALL DPRLicenseNo.184000892IL WHICH ARE LOCATED IN WALLS OR CEILINGS WHICH ARE SWITCHES AS REQUIRED BY THE AUTHORITY HAVING GENERAL CONTRACTOR ASSOCIATED COSTS TO INSTALLBACK WIRE BUILT-IN CLAMPS ' ON SWITCHES AND/OR RECOGNIZED TESTING LABORATORY. TO BE ALTERED OR ARE TO RECEIVE AN ADDITIONAL RECEPTACLES SHALL NOT BE PERMITTED. SURFACE LAYER SUCH AS FURRING, PANELING OR TILE. JURISDICTION. NEW USER DISCONNECT INSTALLATION DEVICES WITHIN A CEILING WHICH IS ALREADY INSTALLED. - 5. SECURE AND PAY FOR ALL PERMITS, GOVERNMENTAL FEES SHALL MATCH EXISTING BUILDING STANDARD. ALL INCLUDE ALL REQUIRED PROTECTION AND CLEAN-UP. 2. BRANCH CIRCUIT HOMERUN WIRING: . .. TAXES AND LICENSES NECESSARY FOR THE PROPER 20. VERIFY CLEARANCES FOR ALL NEW OR EXISTING CONNECTIONS TO LOW VOLTAGE CONTROL TERMINAL FOR EXECUTION AND COMPLETION OF ALL ELECTRICAL WORK. RELOCATED ELECTRICAL WORK BEFORE PROCEEDING WITH THE USER SWITCH WITHIN THE VAV BOX SHALL BE BY 3, PROVIDE ALLOWANCE COST EUP-5 FOR COMPLETE REPAIR a. GENERAL PURPOSE BRANCH CIRCUIT HOMERUNS CITY OP TIGARD THE ELECTRICAL CONTRACTOR. EXACT LOCATIONS OF ALL TO EXISTING EMBEDDED CONDUIT FEEDERS IN FLOOR CONSISTING OF TWO MULTI-WIRE NETWORKS REVIEWED FOR CODE COMPLIANCE CONSTRUCTION. COORDINATE USAGE OF p'I .SFE E SPACE SLAB OR UNDERFLOOR CELL SYSTEMS ACCIDENTALLY 6. PREPARE AND SUBMIT TO BUILDING OWNER'S USER DISCONNECT SWITCHES SHALL BE SUBJECT TO SHALL HAVE PHASE NEUTRAL AND GROUND Approved: Ott G t af . WITH ALL TRADES. IN THE EVENT OF CONFLICTS, NOTIFY CORED. PP r REPRESENTATIVE, GOVERNMENTAL AGENCIES, UTILITYARCHITECTURAL APPROVAL AND SHALL BE WITHIN SIGHT CONDUCTORS INCREASED TO NUMBER 10 AWG, THE ARCHITECT OR ENGINEER BEFORE PROCEEDING WITH OTC' 1 i cAo �� COMPANIES, AND LOCAL CODE OFFICIALS, SHOP DRAWINGS OF UNIT SERVED TO COMPLY- WITH LOCAL CODE THWN AS A MINIMUM. WHERE HOMERUN (ONE F1=1 _ � � �-7� 7 THE WORK. Perrni AND/OR INSTALLATION DETAILS WHICH ARE REQUIRED BY REQUIREMENTS. LABELING OF ALL USER SWITCHES SHALL 1.2 SUBMITTALS/AS-BUILTS OR MORE NETWORKS) EXCEEDS 100 LINEAR FEET, Permiss: �S �,,� 7�,,�► THESE AGENCIES FOR THEIR REVIEW AND APPROVAL. MATCH BUILDING STANDARD INSTALLATIONS, INCLUDING CONDUCTOR SIZE SHALL BE INCREASED ONE WIRE Addre1/� 4,..-- 1.2 ELECTRICAL INSTALLATION MOUNTING HEIGHTS AND METAL STRAP AT TOGGLE SWITCH 1. PROVIDE A WRITTEN GUARANTEE THAT THE ELECTRICAL GAUGE. Suite#: ' 7. NOTIFY THE ARCHITECT, ENGINEER, AND BUILDING OWNER'S 1. PROVIDE TEMPORARY P R IRI F R THETO PREVENT NUISANCE TRIPPING. - INSTALLATION IS FREE FROM MECHANICAL AND ELECTRICAL b. DEDICATED PRINTER AND COMPUTER EQUIPMENT By: Date: /t1/f i7 ROV DEOWE AND WIRING 0 DEFECTS. CONTRACTOR SHALL AT THEIR SOLE COST REPRESENTATIVE IN WRITING OF ANY MATERIALS, PERFORMANCE OF ALL TRADES, FOR THE ENTIRE PERIOD RECEPTACLES (WHERE INDICATED OR SPECIFIED INSTALLATIONS OR APPARATUS BELIEVED TO BE5. REFER TO MECHANICAL ENGINEERING DRAWINGS FOR REPLACE AND/OR REPAIR, TO THE SATISFACTION OF THE ON PLAN) SHALL BE': PROVIDED WITH BRANCH INADEQUATE, UNSUITABLE, IN VIOLATION OF LAWS, OF DEMOLITION AND CONSTRUCTION AND SHALL REMOVE EXACT LOCATIONS AND QUANTITIES OF NEW AND/OR ALL TEMPORARY WIRING AT THE COMPLETION OFTENANT AND TO COMPLY WITH THE MANUFACTURER'S CIRCUIT HOMERUNS SIZED AS FOLLOWS: ORDINANCES, RULES, OR REGULATIONS OF THE RELOCATED AIR TERMINAL DEVICES.. INSTALLATION INSTRUCTIONS, ANY PARTS OF THE CONSTRUCTION. 1) 85 FEET OR LESS: AUTHORITIES HAVING JURISDICTION PRIOR TO PURCHASE6. PROVIDE ALL NECESSARY WIRING AND CONDUIT AS INSTALLATION WHICH MAY FAIL WITHIN A PERIOD OF 12 `.� AND INSTALLATION. 2. ALL EXISTING POWER, SIGNAL, AND COMMUNICATIONS REQUIRED FOR THE RELOCATION VOF ALL AIR TERMINAL MONTHS FROM CONSTRUCTION WRITTEN ACCEPTANCE, IN PHASE CONDUCTORS #12 Um' 8. PREPARE AND SUBMIT TO THE FIRE PREVENTION BUREAU SYSTEMS ARE TO REMAIN IN SERVICE TO PROVIDE FOR UNITS AS SHOWN ON DRAWINGS, OR FOR ALC FIELD ACCORDANCE WITH THE CONTRACT DOCUMENTS, PROVIDED NEUTRAL CONDUCTORS #10 ALL DOCUMENTS, INCLUDING DRAWINGS AND EQUIPMENT THE BUILDING AND EXISTING TENANT FUNCTIONS. CONDITIONS REQUIRING RELOCATION. THAT SUCH FAILURE IS DUE TO DEFECTS IN MATERIAL, GROUND CONDUCTOR #12 rot Liu �? SHOULD IT BECOME NECESSARY TO SHUT-DOWN ANY WORKMANSHIP, OR FAILURE TO FOLLOW THE SUBMITTALS, REQUIRED TO OBTAIN APPROVAL OF THE SYSTEM OR PORTION OF A SYSTEM, APPROVAL IN WRITING 7. PROVIDE FUSED SWITCH. SWITCH SHALL BE FUSED AS2) GREATER THAN 85 FEET: EMERGENCY LIGHTING, FIRE ALARM, LIFE SAFETY, AND SPECIFICATIONS, MANUFACTURER'S INSTALLATION PHASE CONDUCTORS #10 EXIT SIGNSYSTEM(S) INSTALLATIONS. PROVIDE A COPY MUST BE OBTAINED FROM THE BUILDING OWNER'S PER AIR TERMINAL DEVICE MANUFACTURER'S INSTRUCTIONS AND/OR DRAWINGS. PROVIDE WARRANTIES OF AYS E (S) S OV DE GO REPRESENTATIVE TWO (2) WEEKS IN ADVANCE. THE REQUIREMENTS FOR MAXIMUM SUPPLY CIRCUIT RATINGS. FOR ALL EQUIPMENT EXPRESSED BY THE MANUFACTURER NEUTRAL CONDUCTORS #8 Q 0 THE APPROVED DRAWINGS TO THE ARCHITECT, SHUTDOWN SHALL BE ONLY FOR THE PERIOD AND TIME BEYOND 12 MONTHS. ENGINEER AND BUILDING OWNER'S REPRESENTATIVE PRIOR GROUND CONDUCTOR #10 Cup C2I ... TO THE START OF CONSTRUCTION. AGREED UPON. THE FINAL BID IS TO INCLUDE THE COST 1.5 FURNITURE PANEL ELECTRICAL BASE WIRING SYSTEM OF ALL TEMPORARY WIRING AND PREMIUM TIME REQUIRED 2. SHOP DRAWINGS SHALL INCLUDE MANUFACTURER'S NAMES, 3) WHERE TWO OR ' MORE NETWORKS ARE Q 9. CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, MAKE A FOR THE SHUTDOWN. 1. PROVIDE A COMPLETE POWER WIRING INSTALLATION CATALOG NUMBERS, PRODUCT LITERATURE, DIAGRAMS, AND CONTAINED IN A SINGLE HOMERUN = C\I Ct SCHEDULED ARRANGEMENT WITH THE BUILDING OWNER'S INCLUSIVE OF ALL DUPLEX RECEPTACLES, CONDUIT OTHER SUCH DESCRIPTIVE DATA AS MAY BE REQUIRED TO CONDUIT, INCREASE CONDUCTOR SIZE ONE REPRESENTATIVE TO VISIT THE SITE, AND BECOME 3. ALL MATERIALS AND EQUIPMENT SHALL BE ERECTED, RACEWAY, IN-FEED OUTLETS FROM WALL OR FLOOR, IDENTIFY AND REVIEW THE EQUIPMENT. SUBMITTALS WIRE GAUGE . GREATER THAN REQUIRED 0 F ".. INSTALLED, TOOLED, CONNECTED, CLEANED, ADJUSTED, FIRERATING, ETC. PER FURNITURE ABOVE. • . THOROUGHLY FAMILIAR WITH THE BUILDING STANDARDS, CORES, AS E PANEL SHALL BE IN LOGICAL GROUPS (FOR EXAMPLE ALL TESTED, CONDITIONED, AND PLACED IN SERVICE IN INSTALLATION INSTRUCTIONS, WIRING DIAGRAMS AND AS LIGHTING FIXTURES PARTIAL SUBMITTALS WILL NOT BE 4) WHERE ISOLATED GROUND CIRCUITS ARE '�"""" ` �' `�-� MASTER ELECTRICAL SPECIFICATIONS AND EXISTING )• r�„� CONDITIONS RELATING TO THE WORK. FAILURE TO DO SO ACCORDANCE WITH THE MANUFACTURER'S DIRECTIONS AND SHOWN QUANTITATIVELY ON FLOOR PLANS. REVIEWED. SUBSTITUTION OF MATERIALS SUBMITTED IN INDICATED, ASSOCIATED NEUTRAL v./ Fl_ RECOMMENDATIONS, INCLUDING UL REQUIREMENTS. CONDUCTORS SHALL NOT BE USED FOR WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS SHOP DRAWINGS SHALL BE APPROVED BY BUILDING NETWORK NEUTRAL WIRING IN OF THE CONTRACT AND REFERENCES NOTED ABOVE. 4. PERFORM ALL CUTTING, DRILLING, AND PATCHING OF TELE/DATA MOUNTED IN FLOORS' SHALL BE COORDINATED 2. EXACT LOCATIONS OF ALL IN-FEED POWER AND OWNER'S REPRESENTATIVE AND ENGINEER/ARCHITECT IN am ILO COMBINATION WITH GENERAL PURPOSE WRITING PRIOR TO SUBMITTAL. DETERMINATION OF 10. NUMBERED CIRCUITS SHOWN ON PLAN ARE FOR THE EXISTING MASONRY, DRYWALL, CONCRETE, STEEL, OR IRON BY ELECTRICAL CONTRACTOR FOR CLEARANCE OF ALLLIGHTING,CIRCUIT DEVICES CONVEYANCE OF DESIGN INTENT ONLY. ACTUAL FIELD WORK BELONGING TO THE BUILDING IN. ORDER, THAT FIELD CONDITIONS, STRUCTURAL, HVAC DUCTWORK AND EQUALITY TO BE MADE BY ENGINEER PRIOR TO AND/OR0 r� WORK MAY BE PROPERLY INSTALLED. INCLUDE AN APPROVAL. MOTOR LOADS, -ETC. CONDITIONS WILL AFFECT CIRCUITRY. INDICATE THE OTHER TRADES. c. HOMERUN LENGTH SHOAL BE MEASURED FROM ,� ALLOWANCE OF COSTS TO X-RAY, ULTRA SOUND OR r- ACTUAL (AS-BUILT) CIRCUIT NUMBERS INSTALLED AND 3. SUBMIT ELECTRONIC COPIES OF THE FOLLOWING SHOP THE CENTRAL POINT. OF ALL DISTRIBUTED "AS-BUILT" RADAR FLOOR SLABS PRIOR TO WORK. UNDER NO 3. EXACT LOCATIONS OF IN-FEED, INCLUDING FURNITURE DRAWINGS FOR REVIEW: PANELBOARD ORIGINATION ON THE DRAWINGS. SHALL BE AS SPECIFIED AND CIRCUITS TO THE PANELBOARD CIRCUIT BREAKER. CONDITIONS MAY STRUCTURAL WORK BE MODIFIED OR MOUNTED RECEPTACLES, a. LIGHTING FIXTURES AND LAMPS 11. WHERE EXISTING CONDUIT RACEWAY SYSTEMS ARE SHOWN CUT, EXCEPT AT THE DIRECTION OF THE BUILDING DIMENSIONED BY THE FURNITURE • PANEL LAYOUT AND b. LIGHTING CONTROLS DEVICES AND ASSOCIATED ON THE DRAWINGS, IT IS SHOWN DIAGRAMMATICALLY. THE OWNER'S REPRESENTATIVE, ARCHITECT, ENGINEER,,ANO THE ARCHITECTURAL FLOOR PLANS. SECTION 260530 - ALTERATIONS AND ELECTRICAL DEMOLITION FOR EXACT ROUTING OF THE EXISTING CONDUIT RACEWAY APPROVED STRUCTURAL ENGINEER. EQUIPMENT REMODELING SYSTEMS SHALL BE DETERMINED ON THE JOB SITE BY 4. FURNISH AND INSTALL ALL CONDUIT, GREENFIELD, BOXES, c. DISTRIBUTION AND PANELBOARD THE CONTRACTOR. 5. ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL DEVICES, WIRING, FIRE RATED POKE-THRUS, ETC. TO d. WIRING DEVICES 1.1 BUILDING DEMOLITION BE NEW AND OF COMMERCIAL GRADE UNLESS ACCOMMODATE CIRCUITRY SHOWN ON DRAWINGS. e. SECURITY SYSTEM FIRE RATED POKE-THRU FITTINGS AND SURFACE TYPE FLOOR BOXES 12. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH SPECIFICALLY INDICATED AS EXISTING TO BE REUSED ON 5. ARCHITECTURAL FLOOR PLAN AND FURNITURE PANEL f. 1. PERFORM ALL WORK OF A DEMOLITION NATURE REQUIRED THE LATEST APPROVED CONSTRUCTION DOCUMENTS AND CONSTRUCTION DOCUMENTS. LAYOUT SHALL IDENTIFY QUANTITY AND TYPES OF OUTLETSOR NECESSARY FOR THE FULL AND COMPLETE EXECUTION FIRE ALARM SYSTEM EQUIPMENT AND WIRING BUILDING STANDARD ELECTRICAL SPECIFICATIONS. IN THE PER WORKSTATION. WIRE 70 CIRCUITS AS SHOWN ON � OF THE WORK, WHETHER EXPLICITLY SHOWN, SPECIFIED EVENT THAT MORE . STRINGENT REQUIREMENTS THAN 6. ALL WORK REQUIRED FOR THE ELECTRICAL INSTALLATION h. UPS OR NOT SHOWN ON CONSTRUCTION DOCUMENTS. EXACT 3 ISSUED FOR CONSTRUCTION 09.13.17 AS SHOWN ON CONSTRUCTION DRAWINGS SHALL INCLUDE POWER FLOOR PLANS. THOSE DESCRIBED HEREIN ARE SET FORTH UNDER EXTENT OF DEMOLITION WILL NOT. BE FULLY INDICATED ON ALL LABOR, INSTALLATION METHODS, EQUIPMENT, AND 4. PROVIDE AS-BUILT DRAWING FILES AND TWO SETS OF EFFECTIVE UPDATED CODES, LAWS, AND ORDINANCES OF 6. ALL FURNITURE PANEL MOUNTED TASK LIGHTING FIXTURES DRAWINGS. DETERMINE THE :NATURE AND EXTENT OF 2 ISSUED FOR PERMIT REVISIONS 09.13.17 MATERIALS IN STRICT COMPLIANCE WITH ALL BUILDING PRINTS TO THE ARCHITECT/ENGINEER FOR DISTRIBUTION FEDERAL, STATE, AND LOCAL GOVERNING BODIES HAVING SHALL BE FURNISHED BY THE FURNITURE VENDOR ANDDEMOLITION THAT WILL BE NECESSARY BY COMPARING ELECTRICAL STANDARDS AND SPECIFICATIONS. TO THE OWNER AND BUILDING OWNER'S REPRESENTATIVE. JURISDICTION, THE GREATER REQUIREMENTS SHALL BE INSTALLED BY THE E.C. FIXTURES SHALL BE SUPPLIED THE CONSTRUCTION DOCUMENTS WITH ARCHITECTURAL 1 ISSUED FOR BID/PERMIT 05.19.17 CONTRACTOR SHALL OBTAIN STANDARDS. AND AS-BUILT DRAWINGS SHALL INDICATE EXACT CIRCUIT COMPLIED WITH. SUBMIT WRITTEN STATEMENT OF WITH UL LISTED FUSED CORD CONNECTED POWER PLUGS AND DEMOLITION DRAWINGS. TO EXISTING FIELD COMPLIANCE, EXCLUSIONS AND EXEMPTIONS IF ANY, SPECIFICATIONS FROM THE BUILDING OWNER'S NUMBERS, LOCATIONS OF ALL DEVICES, CEILING FIXTURES TO WITH AN INTEGRAL OVERCURRENT� DEVICE TO COMPLY CONDITIONS. ALL EXISTING BASE BUILDING ELECTRICAL REV. DESCRIPTION DATE AND RACEWAY FOR TELECOMMUNICATIONS AND POWER ARCHITECT, REPRESENTATIVE VIA THE ARCHITECT. L BUILDING OWNER'S REPRESENTATIVE AND WITH OCAL CODE REQUIREMENTS. CAP PLUG SHALL EQUIPMENT WHICH WILL NOT . BE REUSED SHALL BE ENGINEER PRIOR TO FINAL BID ACCEPTANCE. NOT INTERFERE WITH OR OBSTRUCT THE USE OF OTHER DISTRIBUTION SYSTEMS AS INSTALLED. PROVIDE OWNER TURNED OVER TO THE• BUILDING OWNER'S ISSUES 1.3 FIRE SEAL SYSTEMS DUPLEX OPENINGS. FURNITURE MANUFACTURER SHALL WITH THREE INSTRUCTION MANUALS IN BOUND FORM REPRESENTATIVE OR REMOVED FROM THE PREMISES AS 13. EXISTING CONDITIONS OF ALL EXISTING BASE BUILDING BE RESPONSIBLE FOR LOCAL CODE COMPLIANCE. CONTAINING DATA COVERING CAPACITIES, MAINTENANCE PHASE:DETERMINED BY THE BUILDING: OWNERS REPRESENTATIVE EQUIPMENT, DEVICES, FIXTURES, AND SYSTEMS THAT 1. ALL NEW POKE-THRU OR FLUSH MOUNT FLOOR FITTINGS AND OPERATION OF ALL EQUIPMENT AND APPARATUS. PRIOR TO THE START OF DEMOLITION, PROVIDE BUILDING REQUIRE REWIRING, REUSE, RELOCATION, OR REQUIRING PENETRATION OF THE FLOOR SLAB SHALL BE 7. ALL WIRING AND DEVICES SHALL BE AS APPROVED BY MANUALS SHALL BE EDITED TO BE PRODUCT SPECIFIC CONSTRUCTION REFURBISHING AS PER DRAWINGS AND SPECIFICATIONS OWNER'S REPRESENTATIVE WITH A WRITTEN LIST OF PROVIDED WITH A BUILDING STANDARD DEVICE, APPROVED AUTHORITY HAVING JURISDICTION FOR FURNITURE PANEL FOR PRODUCTS ACTUALLY INSTALLED ON THE PROJECT. EQUIPMENT AND MATERIAL WHICH WILL BE REMOVED. SHALL BE FIELD VERIFIED PRIOR TO COMMENCEMENT OF BY THE AUTHORITY HAVING JURISDICTION AND LISTED BY SYSTEMS. 5. PROVIDE AS-BUILT RISER/SINGLE LINE DIAGRAMS BUILDING OWNER'S REPRESENTATIVE WILL THEN INFORM DOCUMENTS ANY WORK TO BE COMPLETELY OPERATIONAL. E.C. UL FOR THE PURPOSE. DEVICE SHALL HAVE A UL FIRE g, FURNITURE VENDOR SHALL FURNISH AND DELIVER TO INDICATING THE TENANT BUILDOUT SYSTEM AND ANY BASE CONTRACTOR WHICH ITEMS SHALL BE TURNED OVER TO SHALL SUBMIT A WRITTEN STATEMENT AND ITEMIZED RATING EQUAL TO THE FLOOR SLAB RATING. ALL CORE CONSTRUCTION SITE ALL NECESSARY COMPONENTS FOR A BUILDING SYSTEM REVISIONS/ADDITIONS. THE BUILDING FOR ATTIC STOCK:AND WHICH ITEMS SHALL PHASE LISTING OF ALL EXISTING UNSUITABLE CONDITIONS. SIZES AND LOCATIONS SHALL BE SUBMITTED TO THE COMPLETE POWER BASE 8-WIRE SYSTEM. COMPONENTS BE DISPOSED OF BY THE CONTRACTOR. INCLUDE IN INCLUDE THE FOLLOWING, ALTHOUGH NOT LIMITED TO BUILDING OWNER'S REPRESENTATIVE AND ARCHITECT FOR SHALL CONSIST OF DISTRIBUTION HARNESSES, POST AND 6. PROVIDE OPERATING AND MAINTENANCE MANUALS FINAL BIDS ALL COSTS FOR s•DEMOLITION WORK AND THOSE LISTED: REVIEW AND SUBMITTED FOR APPROVAL BY THE BUILDING HARNESS JUMPERS, RECEPTACLES, AND POWER INCLUDING THE FOLLOWING: EQUIPMENT TURN OVER TO THE BUILDING OWNER'S SHEET DESCRIPTION: a. ELECTRIC PERIMETER BASEBOARD AND/OR CEILING. OWNER'S REPRESENTATIVE APPROVED STRUCTURAL HARNESSES. RECEIVE AND INSTALL ALL COMPONENTS AS a. EQUIPMENT RATINGS AND SELECTED OPTIONS. REPRESENTATIVE AS NOTED ABOVE. FAN POWER HEATER UNITS ENGINEER PRIOR TO CORING. PER FURNITURE VENDOR .INSTRUCTIONS AND b. REQUIRED ROUTINE MAINTENANCE PROCEDURES. ELECTRICAL b. EXIT SIGNS, EMERGENCY LIGHTING FIXTURESPROVIDE MISCELLANEOUS MOUNTING SCREWS FURNISHED.. c. IDENTIFICATION OF QUALIFIED SERVICE AGENCY. 2. OPEN CORES IN EXISTING UNDERFLOOR DUCTS SHALL BE c. LIFE SAFETY/FIRE ALARM SYSTEM DEVICES 2. RACEWAY 3PENETRATIONS SYSTEMSFIRE RATED WALLS ANO d. COMPLETE OPERATIONAL NARRATIVE. CAPPED AT ALL TIMES TO.'-PREVENT ENTRANCE OF SPECIFICATIONS d. CORE LIGHTING AND RECEPTACLE DEVICES FLOORS. FIRESEAL ALL WALL AND FLOOR PENETRATIONS, 9. PROVIDE MULTI-POLE BREAKERS AS REQUIRED TO SERVE FOREIGN MATERIAL DURING DEMOLITION AND e. PANELBOARDS ETC. UTILIZING UL LISTED 3M PRODUCTS INSTALLED AS FURNITURE SYSTEM CIRCUITS. 7. AS-BUILT DOCUMENTS SHALL INCLUDE UPDATE TO BASE CONSTRUCTION. f. METERS AND METER CENTERSBUILDING ELECTRICAL RISER DIAGRAMS. CONTRACTOR 3. ALL EXISTING ELECTRICAL MATERIAL AND EQUIPMENT CIRCUIT BREAKERS PER MANUFACTURER'S INSTRUCTIONS TO MAINTAIN 10. PROVIDE ALL NECESSARY DISCONNECT AND REMOVAL OF SHALL CONTACT OWNER'S REPRESENTATIVE TO g. EXISTING AND NEW FIRE RATINGS. VERIFY EXACT FIRE ALL EXISTING ELECTRIFIED FURNITURE BASE COMPONENTS OBTAINHAL BUILDINGOELECTRICAL DIAGRAMS. UPDATE . WHICH INTERFERES WITH THE 'NEW ADDITION OR THE FLOOR NO.: h. SWITCHES RATING CONDITIONS AND LOCATIONS PRIOR TO FINAL BIDS. WITHIN AREAS SHOWN ON ELECTRICAL DEMOLITION AND APPLICABLE DRAWINGSNGQNS OF RISER DIAGRAM AFFECTED BY REMOVAL OF EXISTING WALLS SHALL BE REMOVED OR 14, SUBMIT THE WRITTEN STATEMENT TO THE BUILDING ALL OPEN CONDUIT SLEEVE PENETRATIONS SHALL BE FIRE ARCHITECTURAL FURNITURE PLANS. EXISTING CIRCUITS THIS PROJECT AND INDICATE ON AS-BUILT SUBMITTALS, RELOCATED. VERIFY REMOVAL -AND NEW LOCATION OF 1 ST OWNER'S REPRESENTATIVE, AND ENGINEER SEALED INSIDE AND OUTSIDE AFTER ALL CABLING IS MAY BE REUSED AS DIRECTED BY POWER PLANS. ALL EQUIPMENT WITH THE BUILDING:'OWNERS REPRESENTATIVE ARCHITECT, COMPLETELY INSTALLED. FIRE SEAL'AETRODS AT EXISTING FURNITURE PANELS TO REMAIN OR BE 8. PROVIDE 48 HOUR ADVANCE WRITTEN NOTICE TO BUILDING AND THE ARCHITECT/ENGINEER PRIOR TO WORK. FLOOR PRIOR TO WORK. IN THE EVENT THAT THE CONTRACTOR SLEEVES SHALL BE SUBJECT TO THE APPROVAL OF THE RELOCATED/MODIFIED SHALL BE PROVIDED WITH NEW OWNER'S REPRESENTATIVE AND ENGINEER FOR A COMMENCES WORK WITHOUT SUBMITTAL, ASSUME ALL CABLING CONTRACTOR. PROVIDE CAPS FOR UNUSED ELECTRIFIED BASE SYSTEMS SIMILAR TO SPECIFIED SYSTEM ' RESPONSIBILITY AND COST TO MAINTAIN THE ABOVE IN PRE-PUNCH WALK-THRU ON JOB SITE PRIOR TO CEILING GOOD WORKING ORDER AND CONDITION. CONDUIT SLEEVES AND FIRE SEAL TO MAINTAIN THE ABOVE. TILE INSTALLATION AND DRYWALL CLOSINGS FOR A VISUAL SECTION 260533 - RACEWAY AND BOXES FOR 'ELECTRICAL SYSTEMS ORIGINAL FIRE RATING OF THE FLOOR SLAB INCLUDING INSPECTION. 15. REFER TO ARCHITECTURAL FLOOR PLAN AND ELEVATION EXISTING CORES THAT ARE NOT TO BE REUSED. VERIFY Ak 11. THE COMPLETE SYSTEM SHALL BE "UL"LISTED. 1.1 GENERAL Scale: Job Number: . 'CT • 'NTIT OF • NET'=TION TH FIEL SECTION 260519 - ELECTRICAL POWER CONDUCTORS AND CABLES NONE 52322 DRAWINGS FOR EXACT LOCATIONS OF ALL ELECTRICAL 12. ALL TELEPHONE AND DATA SYSTEMS JACKS SHALL BE GS PROVIDE A COMPLETE METAL RACEWAY SYSTEM, FITTINGS AND COMMUNICATIONS OUTLETS, INCLUDING SPECIAL USE FURNISHED BY COMMUNICATIONS. CONTRACTOR FOR 1. AND ENCLOSURES FOR ALL ELECTRICAL WIRING SYSTEMS North: Drown: EQUIPMENT (I.E. COPIERS, PANTRY EQUIPMENT, LIGHT 1.4 PACKAGED ROOF TOP UNIT SPECIFICATIONS COMPATIBILITY WITH FURNITURE VENDOR SYSTEM BASE. 1.1 GENERAL AF SWITCHES, PRINTERS, ETC.). ELECTRICAL ENGINEERING COMMUNICATIONS CONTRACTOR SHALL RECEIVE ALL JACKS TO BE INSTALLED FOR THE PROJECT. SYSTEMS SHALL E0 00 1. PACKAGED ROOF TOP UNITS SHALL BE FURNISHED AND INCLUDE, BUT NOT BE'� 'LIMITED TO, POWER, Chk'd: DRAWINGS SHALL BE USED FOR CIRCUITING INTENT AND INSTALLED BY THE MECHANICAL CONTRACTOR. AND INSTALL TO FIT COVER BASE AND CABLE TYPES. COMMUNICATIONS, SECURITY, PAGING, FIRE ALARM, LIFE INFORMATION ONLY. Js SECTION 200170 - SERVICES EXECUTION REQUIREMENTS SAFETY, TEMPERATURE CONTROL AND BUILDING AUTOMATION CONTROLS. %01 QUO:3/91707 7 .. F'*Name:ag.Ol.duy 1:\Option Core - Portland OR\Option Care - Portland OR\DINGS\CAD\Elec\eg_01.dwg 9/13/2017 12:08 PM kmchone Copyright © 2017 by Environmentol Systems Design. Inc. . , • WHITNEY ‘, 2. ELECTRICAL METALLIC TUBING (EMT) SHALL BE USED FOR 2) ALL COPIERS, MOTORS, METAL ENCLOSURES 1. ALL NEW SWITCHES SHALL BE PROVIDED AS INDICATED ON 4. S.C. SHALL PROVIDE A RECORD SHOP DRAWING AND FIRE ALARM SPECIFICATIONS ARCHITECTS, INC. ALL WALL MOUNTED POWER AND COMMUNICATIONS FOR ELECTRICAL UTILIZATION EQUIPMENT, ' "'''' PLAN AS 277 VOLT SINGLE POLE 20 AMPERE TOGGLE AS-BUILT OF ALL SECURITY WIRING, DEVICES, OUTLETS RUNNING IN PARTITIONS, BELOW RAISED FLOORS, PANTRY EQUIPMENT, ELECTRICAL COMMERCIAL GRADE UNLESS NOTED OTHERWISE. COLOR CONNECTIONS, AND INSTALLATION OF CONDUIT RACEWAY PART 1 - GENERAL 700 Commerce Drive I Suite 350 Oak Brook,it 60.523 I USA OR ABOVE CEILINGS. ALL EMT FITTINGS SHALL BE STEEL EQUIPMENT UTILIZING A WATER AS SELECTED BY ARCHITECT. FOR APPROVAL BY TENANT, BUILDING OWNER'S 1 1 SUMMARY T r 630.571.1118 I F : 630.571.0518 ' COMPRESSION TYPE. SET SCREW EMT FITTINGS ARE CONNECTION, HEATING EQUIPMENT, FLOOR 2. WALL BOX DIMMERS SHALL BE DIGITAL, PRESET, SLIDER REPRESENTATIVE AND ENGINEER. whitney-architects.com PERMITTED ONLY IN PARTITIONS. CONDUITS LARGER THAN OUTLET FITTINGS, SURFACE MOUNTED TYPE FOR INCANDESCENT LOADS. RATED 600 VA OR AS 5. ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED. A. SECTION PROVIDES THE REQUIREMENTS FOR THE EXTENSION OF TWO INCH DIAMETER OR CONDUITS OF ANY SIZE ROUTED RACEWAY, AND FURNITURE SYSTEMS SHALLAN EXISTING SPRINKLER MONITORING SYSTEM INCLUDING OUTDOORS SHALL BE INTERMEDIATE METAL CONDUIT IMC . BE PROVIDED WITH A GREEN EQUIPMENT REQUIRED FOR THE LOAD. IL. CORPORATE LIC. 84-001 ssa j ( ) 6. S.C. SHALL COORDINATE ALL BASE BUILDING AUTOMATIC SMOKE DETECTORS AND AUXILIARY ALARM GROUNDING CONDUCTOR IN THE SAME 3. ALL NEW RECEPTACLES SHALL BE PROVIDED AS INDICATED REQUIREMENTS WITH THE BUILDING OWNER'S • EQUIPMENT AND INSTALLATION MATERIALS FOR THE MONITORING 3. MINIMUM CONDUIT SIZE SHALL BE 1/2 INCH FOR CONDUIT AS THE PHASE CONDUCTORS _ ON PLANS AS NEMA 5-20R COMMERCIAL GRADE UNLESS REPRESENTATIVE PRIOR TO INSTALLATION. OF NEW DUCT SMOKE DETECTORS. GENERAL LIGHTING AND POWER CIRCUITRY. NO 1/2 INCH AND SHALL BE CONNECTED TO THE NOTED OTHERWISE. ISOLATED GROUND RECEPTACLES (.1 . 10 RACEWAY SHALL BE INSTALLED FOR TELECOMMUNICATION PANELBOARD EQUIPMENT GROUNDING BUS SHALL BE NEMA 5-20 RIG. 7. E.C. SHALL COORDINATE ALL SPECIAL BOXES REQUIRED SYSTEMS. SEE REQUIREMENTS FOR COMMUNICATION ALTHOUGH NOT SHOWN ON CONSTRUCTION FOR THE INSTALLATION OF SECURITY EQUIPMENT/DEVICES 1.2 REFERENCES SYSTEMS RACEWAY. DRAWINGS. RETROFIT A PANEL WITH A , 4. ALL COVERPLATES SHALL BE METAL, COLOR AS SELECTED WITH SECURITY CONTRACTOR PRIOR TO INSTALLATION. A. THE WORK IS SUBJECT TO APPLICABLE PORTIONS OF THE Environmental Systems Design,Inc. GROUND BUS IF NONE IS AVAILABLE. BY ARCHITECT. PROVIDE TYPE 302 BRUSHED STAINLESS FOLLOWING CODES AND STANDARDS IN EFFECT AT THE TIME OF 175 West Jackson Blvd.Suite 1400 4. FLEXIBLE CONDUIT CONNECTIONS TO RECESSED LIGHTING 3) CIRCUIT BREAKERS OF EACH STEEL PLATES IN BREAK ROOMS AND KITCHENS. BIDDING THE PROJECT: Chicago,Illinois 60604 FIXTURES SHALL BE MADE WITH FLEXIBLE STEEL CONDUIT, MULTI-CONDUCTOR BRANCH CIRCUIT • 312 372 1200 fax 312 372 1222 1. NFPA 70 - NATIONAL ELECTRICAL CODE. DPR License No.84-000892 IL obal.com 3/8 INCH MINIMUM, AND SHALL BE APPROVED FOR SHALL BE MULTIPOLE COMMON TRIP TYPE SECTION 265100 - INTERIOR LIGHTING � 2. NFPA 72 - NATIOAL FIRE ALARM AND SIGNALING CODE. PLENUM CONDITIONS BY THE AUTHORITY HAVING TO PROVIDE A MEANS FOR 3. INTERNATIONAL BONNDING CODE. JURISDICTION WHERE APPLICABLE. PROVIDE FLEXIBLE SIMULTANEOUSLY DISCONNECTING ALL 1.1 LIGHTING SYSTEMS AND CONTROL SYSTEMS STEEL CONDUIT TO ALL NEW FIXTURES AND EXISTING UNGROUNDED CONDUCTORS. CIRCUITS4. UNDERWRITERS LABORATORIES (UL) LIGHT FIXTURES WHERE CODE APPROVED RACEWAY SHALL BE ARRANGED FOR THE PROPER 1. VERIFY THE NEW CEILING CONSTRUCTION TYPE WITH 5. REQUIREMENTS OF THE AUTHORITY OR AUTHORITIES CONNECTIONS DO NOT EXIST. INSTALLATION OF MULTIPLE DEVICES. ARCHITECTURAL DETAILS AND/OR EXISTING CEILING HAVING JURISDICTION. 5. FINAL CONNECTIONS TO MOTORS SHALL BE MADE WITH ALTER THE CIRCUIT NUMBER ASSIGNMENT CONDITIONS BEFORE ORDERING LIGHTING FIXTURES SO AS I LIQUID TIGHT FLEXIBLE STEEL CONDUIT OR FLEXIBLE INDICATED ON THE DRAWINGS TO TO CONFIRM PROPER MOUNTING. 1.3 SYSTEM DESCRIPTION METALLIC TUBING FMT IF IN A PLENUM, 1 2 INCH ACCOMPLISH THE NECESSARY POLE ( ) / ADJACENCY FOR MULTIWIRE CIRCUIT. 2. IN SUSPENDED CEILINGS, SUPPORT CONDUITS AND A. FURNISH AND INSTALL THE FOLLOWING WORK: ENGINEER _. - MINIMUM. JUNCTION BOXES DIRECTLY FROM THE STRUCTURAL SLAB, , DECK OR FRAMING PROVIDED FOR THAT PURPOSE. 1. SPRINKLER MONITORING SYSTEM - EXTENSION OF 6. BUILDING RACEWAY INSTALLATION STANDARDS: 1.2 GENERAL AND SPECIAL POWER SYSTEMS LIGHTING AND POWER BRANCH CIRCUIT CONDUITS SHALL EXISTING SYSTEM. a. INSTALL ALL NEW CONDUIT RACEWAYS AND BOXES 2. PROVIDE ADDITIONAL SYSTEM CAPACITY AS NECESSARY TO FOR ALL SYSTEMS TIGHT-UP TO THE BOTTOM OF 1. EACH LIGHT SWITCH, RECEPTACLE, OR OTHER NOT BE CLIPPED TO THE CEILING SUPPORT WIRES OR THE STRUCTURAL FLOOR SYSTEM AND SUPPORTED MISCELLANEOUS WALL MOUNTED DEVICE SHALL BE SPLINE UNLESS THE CEILING SYSTEM HAS.. BEEN ACCOMMODATE NEW INITIATING DEVICES: FROM THE STRUCTURAL FLOOR DECK ABOVE WITH PROVIDED WITH A GALVANIZED PRESSED STEEL OUTLET SPECIFICALLY DESIGNED FOR THAT PURPOSE AND BUILDING OWNER'S REPRESENTATIVE APPROVED BOX, OF NOT LESS THAN #14 U.S. GAUGE STEEL. . -.:,.._.. APPROVAL HAS BEEN GRANTED BY THE BUILDING 1.4 SYSTEM SUPERVISION ANCHORS. LOCATION OF ANCHOR SUPPORTS CONDUITS SHALL BE FASTENED WITH LOCKNUTS AND OWNER'S REPRESENTATIVE AND THE ARCHITECT. BUSHINGS. CLOSE ALL UNUSED KNOCKOUTS. THERE A. OPERATION OF A DUCT-TYPE SMOKE DETECTOR, WATERFLOW L U SHALL NOT PENETRATE THE UNDERFLOOR POWER, SHALL BE SUFFICIENT ROOM FOR WIRES AND BUSHINGS 3. RECESSED LIGHT FIXTURES IN PLENUM CEILINGS SHALL SWITCH, OR TAMPER SWITCH SHALL AUTOMATICALLY: i__ti TELEPHONE AND DATA CELL SECTIONS. ALLBE PLENUM APPROVED. ANCHORS SHALL BE DRILLED IN, NOT SHOT AND DEEP BOXES SHALL BE INSTALLED WHERE REQUIRED. 1. MATCH BASE BUILDING FIRE ALARM SYSTEM OPERATION (POWDER ACTUATED). ATTACH EACH BOX TO TWO SEPARATE STUDS. 4. ALL FLUORESCENT AND HID LIGHTING FIXTURES, EXISTING AND SEQUENCE. fu. W OR NEW, SHALL BE PROVIDED A UNIT DISCONNECT b. INSTALL ALL NEW CONDUIT RUNS ABOVE AND 2. INSTALL WALL OUTLETS WITH A MINIMUM HORIZONTAL '' .,; DEVICE. SUBMIT UNIT COST FOR QUANTITY ADJUSTMENTS. B. IN THE EVENT OF A MALFUNCTION IN AN ALARM INITIATING < >,„1,-, Ct . OVER THE TOP OF ALL NEW AND/OR EXISTING DISTANCE OF 12" BETWEEN OUTLETS IN NON-FIRE RATED DEVICE, SIGNALING LINE CIRCUIT, OR POWER SUPPLY, MATCH DUCTWORK, PIPING, CONDUITS, PULLBOXES, ETC. WALLS AND 24" IN FIRE RATED WALLS. APPLY FIRE 5. PROVIDE NEW LAMPS WITHIN ALL EXISTING AND NEW THE BASE BUILDING SPRINKLER MONITORING 'SYSTEM OPERATION ELECTRICAL CONTRACTOR SHALL PROVIDE ALL BARRIER PADS TO BOXES IF THE TOTAL BOX DENSITY LIGHT FIXTURES AT THE COMPLETION OF CONSTRUCTION. ( AND SEQUENCE. Co) C) NECESSARY ACCESSIBLE PULLBOXES. CONDUIT EXCEEDS THE U.L. MAXIMUM PENETRATIONS LIMITATIONS. LAMP TYPE SHALL BE AS SELECTED BY ARCHITECT BENDS SHALL NOT EXCEED CODE REQUIREMENTS COMPATIBLE WITH INSTALLED BALLASTS. ) C. ANY OPENS, GROUNDS OR DISARRANGEMENT OF SYSTEM WIRING r� c A SINGLE RUN. E.C. SHALL PROVIDE ALL 3. PROVIDE ALL SPECIAL OUTLET BOXES REQUIRED TO OR A SHORT ACROSS ANY DEVICE OR SYSTEM WIRING SHALL = C"\ii Ct WITHINXES FIELD SIZED AS REQUIRED DUE TO ENCLOSE RECEPTACLES IN PARTITIONS AND ELECTRICAL 6. NEW EXIT SIGNS SHALL BE L.E.D. TYPE AND SHALL NOT AUTOMATICALLY: EXISTING CONDITIONS. NEW CONDUIT AND FURNITURE BASE SYSTEMS. EXCEED 5 WATTS PER FACE. PROVIDE WITH FIELD 1. MATCH BASE BUILDING SPRINKLER MONITORING: SYSTEM 0 r- A DRIVER ASSEMBLY. PULLBOXES THAT CANNOT BE INSTALLED ABOVE 4. PROVIDE ALL NECESSARY PROPERLY SIZED WALL OR REPLACEABLE L.E.D./DRIVER OPERATION AND SEQUENCE. . - EXISTING DUCTS AND PIPES SHALL BE INSTALLED MILLWORK MOUNTED BOXES, RINGS, SUPPORTS, AND SECTION 270000 - COMMUNICATION SYSTEMS BELOW NEW OR EXISTING DUCTWORK AND SHALL DEVICES AS REQUIRED VIA COORDINATION WITH („f) BE MOUNTED TIGHT UP TO THE BOTTOM OF DUCT ARCHITECTURAL WALL SECTIONS, AUDIO-VISUAL SYSTEMS 1.5 SUBMITTALS WITH 90 DEGREE CONDUIT BENDS UP THE AND MILLWORK DETAILS. 1.1 REFER TO T SERIES DRAWINGS. A. FOR ALL WORK SPECIFIED, SUBMITTALS SHALL INCLUDE TYPE 1 Q_ 1"C SIDEWALL OF DUCT. SUPPORTS SHALL NOT PENETRATE DUCTWORK, AND SHALL BE - (MANUFACTURER'S NAME) AND TYPE 2'- (PRODUCT DATA) �� INDEPENDENT OF ALL DUCTWORK SUPPORTS. SECTION 262416 - PANELBOARDS SECTION 281000SECURITY INFORMATION. IN ADDITION, SUBMITTALS FOR THE WORK LISTED 0 N---- DIRECT CONTACT OF CONDUIT RACEWAY SYSTEMS 1.1 SECURITY SYSTEM BELOW SHALL INCLUDE THE INDICATED TYPE OF INFORMATION. (.(:) WITH DUCTWORK OR PIPING SHALL BE PROVIDED 1.1 GENERAL B. SHOP DRAWINGS: INCLUDE SYSTEM WIRING DIAGRAM SHOWING `1"--"' WITH VIBRATION SEPARATION METHOD APPROVED 1. ALL CARD READER CABLING SHALL BE INSTALLED IN 3/4 EACH DEVICE AND WIRING CONNECTION; COMPLETE ONE-LINE 1. ALL NEW ELECTRICAL WORK OR MODIFICATIONS TO INCH EMT RACEWAY UNLESS NOTED OTHERWISE. ALL BY THE ENGINEER AND BUILDING OWNER'S EXISTING BUILDING DISTRIBUTION PANELS, TENANT CONDUIT HOMERUNS LONGER THAN 50 FEET SHALL BE 1 RISER DIAGRAM; DESIGN LOAD CALCULATIONS. TO SUPPORT SIZE REPRESENTATIVE. PANELBOARDS, METERS, ETC. SHALL BE INSTALLED AS OF STANDBY BATTERIES AND REQUIRED SPARE CAPACITY. c. NEW CONDUIT RUNS OR PULLBOXES SHALL NOT INDICATED ON THE ELECTRICAL DISTRIBUTION DIAGRAM. INCH EMT, UNLESS NOTED OTHERWISE. PROVIDE PLENUM BE INSTALLED LESS THAN TWO INCHES ABOVE ELECTRICAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS APPROVED PULLBOXES WHERE REQUIRED. MOUNT ALL 1. SHOP DRAWINGS SHALL BE IN FULL COMPLIANCE WITH RECESSED LIGHTING FIXTURES UNLESS APPROVED OF ALL EQUIPMENT TO BE INSTALLED INDICATING PULLBOXES IN TENANT SECURED CEILING SPACE. THE REQUIREMENTS OF NFPA 72. BY THE ENGINEER AND THE BUILDING OWNER'S ELECTRICAL ROOM FLOOR PLAN LAYOUT, ELEVATIONS, AND 2. E.C. SHALL FURNISH AND INSTALL LOW VOLTAGE 2. ARCHITECTURAL FLOOR PLANS SHALL BE PREPARED AT REPRESENTATIVE. ALL DIMENSIONS FOR APPROVAL OF BUILDING OWNER'S TRANSFORMER(S) AS PER THE SECURITY SYSTEM 1/8" 1'-O". 1 d. NEW CONDUIT RUNS OR PULLBOXES SHALL NOT REPRESENTATIVE AND ENGINEER PRIOR TO INSTALLATION. REQUIREMENTS. PROVIDE A NEMA 1 ENCLOSURE. E.C. 3. THE SHOP DRAWINGS SHALL CONTAIN THE ACTUAL BLOCK OR PREVENT FULL AND COMPLETE ACCESS LOCATION OF ALL INITIATING, EXTINGUISHING, TROUBLE, ELECTRICAL EQUIPMENT CODE REQUIRED CLEARANCES IN FRONT OF ALL SHALL PROVIDE POWER SUPPLY (120V, 20A, 1PH) TO AND OPERATION OF NEW OR EXISTING HVAC ACCESS DOORS, SHALL BE MAINTAINED AT ALL ALL TRANSFORMER(S) AND WIRE COMPLETE. COORDINATE COMMUNICATION, AND SUPERVISORY EQUIPMENT AS EQUIPMENT, PIPING VALVES, TIMES FOR EXISTING AND NEW EQUIPMENT. RETROFIT ALL SUCH REQUIREMENTS WITH THE SECURITY REQUIRED BY THESE SPECIFICATIONS. JUNCTION BOXES, MIXING BOXES, PULLBOXES, ISOLATED GROUND BUS AND WIRE BACK TO THE DERIVED 4. EACH DEVICE AND CONTROL EQUIPMENT SHALL BE NOTED 2 ISSUED FOR CONSTRUCTION 09.13.17 CLEANOUTS, ETC. ., A,_ CONTRACTOR. WITH THE DESIGNATION OF ITS ZONE CIRCUIT. SYSTEM SOURCE. ZONE/ CIRCUIT. NEW CONDUIT AND BOXES TO BE INSTALLED 3. EXACT LAYOUT AND INSTALLATION OF CONDUIT RACEWAYS 5. ON EACH FLOOR PLAN, PROVIDE A SCHEDULE INCLUDING 1 ISSUED FOR BID/PERMIT 05.19.17 WITHIN ALL EXISTING FINISHED BUILDING 2. ALL NEW CIRCUIT BREAKERS FOR EXISTING PANELBOARDS INCLUDING ALL BACK BOXES FOR CARD READERS AND ALL ZONES/CIRCUITS ON THAT FLOOR. .. DRYWALL, FURRED CORE WALLS, PARTITIONS, AND AND DISTRIBUTION PANELBOARDS SHALL MATCH EXISTING FLEXIBLE 3/4 INCH CONNECTIONS TO DOOR FRAMES " REV. DESCRIPTION DATE • COLUMNS SHALL BE INSTALLED WITH FLEXIBLE BUILDING PANELBOARD MANUFACTURER AND CIRCUIT FROM MAIN RACEWAY FOR DOOR STRIKES, ETC.,' SHALL 6. A MASTER ZONE/CIRCUIT LIST, ON 8- 1/2 X 11 SHEETS RACEWAYS NOT MORE THAN 6'-0" LONG OR BREAKER TYPE. ALL CIRCUIT BREAKERS SHALL BE BOLT BE COORDINATED WITH THE SECURITY CONTRACTOR PRIOR OF PAPER, IN COLUMN FORM, TO SHOW ALL OF THE ISSUES EMT. ELECTRICAL CONTRACTOR SHALL INCLUDE ON TYPE. AIC RATING OF NEW CIRCUIT BREAKER SHALL/ 5 , ,,; TO SYSTEM INSTALLATION. ZONE CIRCUITS WITHIN THE SYSTEM FOR ALL EQUIPMENT. , ALL COSTS FOR DRYWALL ACCESS, CUTTING, MATCH AIC RATING OF PANELBOARD IN WHICH IT IS AT A MINIMUM, THE MASTER ZONE/CIRCUIT LIST SHALL PHASE: PATCHING, PAINTING, ETC. IN BIDS FOR SUCH INSTALLED. SERIES RATED CIRCUIT BREAKERS, IF 4. E.C. SHALL COORDINATE ALL SPECIAL BOXES REQUIRED PROVIDE DESIGNATIONS FOR .EACH INDIVIDUAL I CONDITIONS. FIELD VERIFY ALL LOCATIONS ON UTILIZED, SHALL BE UL LISTED FOR A SERIES RATING FOR THE INSTALLATION OF SECURITY EQUIPMENT/DEVICES ZONE/CIRCUIT FLOOR LEVEL, LOCATION ON FLOOR, CONSTRUCTION I SITE PRIOR TO FINAL BIDS. EXCEPTIONS DURING WITH THE EXISTING DISTRIBUTION EQUIPMENT. WITH SECURITY CONTRACTOR PRIOR TO INSTALLATION. DESCRIPTION OF THE MONITORED, CONTROLLED, DETECTED BIDS SHALL BE SUBMITTED IN WRITING. 3. PROVIDE A NEW TYPE WRITTEN PANEL DIRECTORY AT THE 1.2 SECURITY SYSTEMS CONTRACTOR SHALL: AND/OR FUNCTION THE ZONE/CIRCUIT IS PERFORMING, DOCUMENTS f. EXAMINE THE CONSTRUCTION SITE WITH RESPECTAND THE NUMBER AND TYPE OF EQUIPMENT FOR EACH TO COORDINATION WITH CONSTRUCTION DRAWINGS, COMPLETION OF THE PROJECT FOR EACH PANEL 1. ALL ELECTRIC STRIKES AND ELECTRIC HINGES SHALL BE ZONE/CIRCUIT. PHASE ACTUAL FIELD CONDITIONS, DOOR FRAME HEIGHTS, CHANGED. EACH CIRCUIT BREAKER SHALL BE LABELED FURNISHED, INSTALLED AND WIRED COMPLETE BY THE 7. DEVICE WIRING DIAGRAM FOR EACH TYPE OF DEVICE PIPING OBSTRUCTIONS, DUCTWORK HEIGHTS AND TO IDENTIFY LOAD TYPE, ARCHITECT'S ROOM NUMBER, AND QUADRANT FLOOR PLAN LOCATION. SUBMIT LABEL SECURITY CONTRACTOR (S.C.). S.C. SHALL FURNISH AND FURNISHED. LEVELS, FLOOR LEVELS, CEILING HEIGHTS, ETC. METHOD AND SAMPLE FOR APPROVAL TO BUILDING INSTALL ALL SECURITY SYSTEM CABLING AND 8. POINTS OF INTERFACE CONNECTIONS INCLUDING SOUND SHEET DESCRIPTION: PRIOR TO FINAL. BIDS. MISCELLANEOUS HARDWARE. S.C. SHALL WIRE ALL SYSTEMS, ELEVATOR, MECHANICAL EQUIPMENT, SECURITY g. ALL NEW BUILDING STANDARD RACEWAYS, OWNER'S REPRESENTATIVE AND ENGINEER. PROVIDE STRIKES COMPLETE TO THE SECURITY CONTROL PANEL. SYSTEMS, ETC. ELECTRICAL i EQUIPMENT, DEVICES, AND MATERIALS SHALL BE COPIES OF ALL PANELBOARD DIRECTORIES TO THE COORDINATE ALL ELECTRIC STRIKE HARDWARE WITH 9. COMPLETE NARRATIVE ON THE OPERATION OF THE SYSTEM EQUAL TO OR GREATER IN QUALITY TO EXISTING BUILDING OWNER'S REPRESENTATIVE UPON COMPLETION. ARCHITECT FOR DOOR HARDWARE AND FRAME DETAILING EACH EVENT IN THE •SYSTEM AND THE SPECIFICATIONS APPROVED BUILDING STANDARD MATERIALS 4. ALL EXISTING CIRCUIT BREAKERS SHALL BE EXERCISED COMPATIBILITY. RESULTING ACTIONS THROUGHOUT .THE SYSTEM AND PRESENTLY INSTALLED IN THE BUILDING. ALL FOR SAFE OPERATION. IN THE EVENT THAT FAULTY INTERCONNECTIONS TO OTHER SYSTEMS. NEW EQUIPMENT, DEVICES, AND MATERIALS SHALL 2. S.C. SHALL PROVIDE SECURITY PANEL AND CARD READER 10. SHOP DRAWINGS SHALL BE SENT TO THE RESPECTIVE BE SUBJECT TO THE APPROVAL OF THE BUILDING CIRCUIT BREAKERS ARE ENCOUNTERED, REPLACE WITH INTERFACE(S). ELECTRICAL CONTRACTOR (E.C.) SHALL CONTRACTORS, SUPPLIERS, ETC. FOR PROPER , NEW MATCHING CIRCUIT BREAKERS. PROVIDE ANFLOOR NO.: I OWNER'S REPRESENTATIVE AND THE ENGINEER, ALLOWANCE TO REPLACE A MINIMUM OF 10% OF CIRCUIT PROVIDE HARDWIRED POWER SUPPLY (120V, 20A; 1PH). COORDINATION WHERE THEIR WORK IS INTERDEPENDENT SUBMIT ALL SHOP RAWINGS TO FBUILDING BREAKERS PER PANELBOARD UTILIZED FOR THIS PROJECT. DUIT REQUIREMENTS ATECABLE ETERMINATION TY MON TORING SYST .SIGNALS OR EMCONTROLS THESE WOUNCLUDE FROM LD SPRINKLER OW ER'S REPRESENTATIVE OR REVIEW. LOCATIO SSHALL BE COORDIND W THTHE SECURITY THOSE 1ST h. ALL EXISTING AND NEW JUNCTION BOXES SERVING 5. NEW PANELBOARD(S) SHALL BE RATED AS FOLLOWS: CONTRACTOR PRIOR TO INSTALLATION. ALL CONDUIT ASSOCIATED WITH VERTICAL TRANSPORTATION, AUTOMATIC LIGHTING AND POWER SHALL HAVE UPDATED a. 208Y/120 V: 42 KAIC SERIES RATED WITH A MAIN RUNS AT SECURITY PANEL SHALL BE SURFACE MOUNTED TEMPERATURE CONTROLS, SECURITY; DOOR LOCKS, FLOOR CIRCUIT NUMBERS AND PANEL TAGS FOR ALL C/B IN PANEL. ON WALL. S.C. SHALL TERMINATE ALL CABLES AT CARD MOTORIZED DOORS, ETC. WIRING LABELED WITHIN THE JUNCTION BOX AND READER INTERFACE(S) AND AT THE SECURITY CONTROL 11. SHOP DRAWINGS SHALL BE REVISED AND RESUBMITTED IN ON COVERPLATES. b. 480Y/277 V: 22 KAIC. PANEL. S.C. SHALL PROVIDE SUFFICIENT CABLE. SLACK ACCORDANCE WITH THE SPECIFIED SHOP DRAWING 1) ALL HANGER AND/OR ROD SUPPORT ELECTRICAL CONTRACTOR MAY PROVIDE PANELBOARD(S) AND SHALL LABEL ALL SECURITY CABLING. PROCEDURES. THE CONTRACTOR '`SHALL SUBMIT ALL Scale: Job Number: SYSTEMS SHALL BE SUPPORTED TO THE WITH LOWER SHORT CIRCUIT CURRENT RATING(S) (SCCR) SHOP DRAWINGS TO THE BUILDING . DEPARTMENT FOR NONE 52322 BOTTOM OF STRUCTURAL DECK, WHERE AFTER SUBMISSION OF ALL SHORT CIRCUIT CALCULATIONS 3. S.C. SHALL PROVIDE A COMPLETE SECURITY OPERATING APPROVAL ONLY AFTER REVIEW BY THE PENETRATIONS WILL NOT AFFECT EXISTING INDICATING CALCULATED SCCR BASED ON EXISTING SYSTEM INCLUDING ALL MATERIALS, DEVICES, ETC. ALL ARCHITECT/ENGINEER. North: Drawn: AF EMBEDDED RACEWAYS AND STRUCTURAL CONDITIONS TO ELECTRICAL ENGINEER FOR APPROVAL. SYSTEM REQUIREMENTS, FUNCTIONS, OPERATIONS, ETC. MEMBERS. COORDINATE ALL STRUCTURAL t te.-1, SHALL BE APPROVED BY THE SECURITY CONSULTANT PRIOR TO SYSTEM INSTALLATION. C. PRODUCT DATA: SUBMIT CATALOG DATA SHOWING ELECTRICAL Chk'd: E 0 . 0 1 FLOOR PENETRATIONS. WITH BUILDING CHARACTERISTICS AND CONNECTION REQUIREMENTS. JS OWNER'S REPRESENTATIVE AND SECTION 262726 - WIRING DEVICES I STRUCTURAL ENGINEER. . Plot Dur:1/912017 1.1 GENERAL ,* 01 't:Option Core - Portland OR\Option Core - Portland OR\DWGS\CAD\Elec\eg_01.dwg 9/13/2017 12:08 PM kmchone Copyright 0 2017 by Environmentot Systems Design. Inc. D. TEST REPORTS: INDICATE PROCEDURES AND RESULTS FOR 3.1 FURNISH AND INSTALL A COMPLETE, OPERATIONAL, I. CONNECT ALL NEW SPRINKLER MONITORING DEVICES TO \/PiyTJ. I 1 N E Y SPECIFIED FIELD TESTING AND INSPECTION. PROVIDE CODE-COMPLIANT EXTENSION OF THE EXISTING SPRINKLER EXISTING BUILDING SPRINKLER MONITORING SYSTEM. DEVICES, A "RECORD OF COMPLETION"IN COMPLIANCE WITH NFPA 72. MONITORING SYSTEM. INCLUDE ALL NECESSARY MATERIALS, LABOR, CABLE, AND EQUIPMENT SHALL MATCH EXISTING BUILDING ARCHITECTS, INC. TESTING, PROGRAMMING, MODIFICATIONS, COORDINATION, ETC. AS STANDARD. E. MANUFACTURER'S FIELD REPORTS: INDICATE ACTIVITIES OUTLINED BELOW. 700 Commerce Drive I Suite 350 ON-SITE, ADVERSE FINDINGS, AND RECOMMENDATIONS. J. EXPANSION OF EXISTING SPRINKLER MONITORING SYSTEM SHALL Oak Brook,II.60523 I USA 3.2 ALL NECESSARY WORK AND DOCUMENTATION SHALL BE PROVIDED MATCH EXISTING SEQUENCE OF OPERATION. T: 630.571.1118 I F : 630.571.0518 •1.6 CLOSEOUT SUBMITTALSWhitney-architects.com BY THE ELECTRICAL CONTRACTOR (E.C.). CONTRACT DOCUMENTS K. REPROGRAM THE EXISTING SPRINKLER MONITORING CONTROL INDICATE AREA OF SYSTEM COVERAGE WITH CONTRACT LIMITS AND PANEL AND ANNUNCIATOR TO INCLUDE ALL NEW DEVICES AND A. PROJECT RECORD DOCUMENTS: RECORD ACTUAL LOCATIONS OF RECOMMENDED LOCATION OF DEVICES. EXACT QUANTITIES AND EQUIPMENT. IL. CORPORATE LIC. 184-001580 SPRINKLER MONITORING EQUIPMENT. LOCATIONS OF EQUIPMENT SHALL BE AS DETERMINED IN FIELD. B. OPERATION AND MAINTENANCE DATA: SUBMIT MANUFACTURER'S E.C. IS RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE 3.11 INSTALLATION • STANDARD OPERATING AND MAINTENANCE INSTRUCTIONS. CODES AND REQUIREMENTS OF AUTHORITY HAVING JURISDICTION. A. ALL WIRING FOR THE SYSTEM SHALL BE IN ACCORDANCE WITH ESD ARTICLES 760, 725, AND 800. OF THE NATIONAL ELECTRIC 3.3 ALL REQUIRED SPRINKLER MONITORING SYSTEM DEVICES AND 1.7 QUALIFICATIONS COMPONENTS, INCLUDING SPECIAL BACKBOXES, PLATES, ETC., CODE AND ALL LOCAL AMENDMENTS TO APPLICABLE CODES. Environmental Systems Design,Inc. A. MANUFACTURER: COMPANY SPECIALIZING IN MANUFACTURING SHALL BE U.L. LISTED AND APPROVED BY THE AUTHORITY HAVING 175 West Jackson Blvd.Suite 1400 B. PROVIDE COMPLETE WIRING ' AND CONDUIT BETWEEN ALL4 is 6060 PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM FIVE JURISDICTION AND SHALL BE FURNISHED AND INSTALLED BY THE EQUIPMENT. UNLESS SPECIFIED OTHERWISE, ALL SYSTEM 312372 1200 fax Chicago,Illino312 372 is YEARS EXPERIENCE AND WITH SERVICE FACILITIES WITHIN 100 E.C. WIRING SHALL BE IN A SEPARATE RACEWAY, MAXIMUM 40% FILL, DPRLice.edgI 84Q00892IL MILES OF PROJECT. WITH APPROVED FIRE ALARM. CABLE AS RECOMMENDED BY B. INSTALLER: CERTIFIED FIRE ALARM INSTALLER WITH SERVICE3.4 E.C. SHALL IDENTIFY AND LABEL ALL RACEWAYS AND JUNCTION MANUFACTURER. WHERE CABLING, IN LIEU OF INDIVIDUAL FACILITIES WITHIN 100 MILES OF PROJECT. BOXES CONCEALED ABOVE CEILING TILES OR EXPOSED RUNS CONDUCTORS, IS USED, CONDUITS OF PROPER SIZE SHALL BE AS "SPRINKLER MONITORING" EVERY 20 FEET AND AT ALL INSTALLED FROM ALL EQUIPMENT AND DEVICES INTO C. DESIGN SPRINKLER MONITORING UNDER DIRECT SUPERVISION OF TERMINATIONS WITH PERMANENT RED MARKING PEN. E.C. SHALL ACCESSIBLE SPACES AND ALL- DEVICES SHALL BE MOUNTED A PROFESSIONAL ENGINEER EXPERIENCED IN DESIGN OF THIS ALSO INCLUDE ALL COSTS FOR MATERIALS, RECEIVING, STORAGE, UPON AND ALL CONNECTIONS MADE WITHIN LISTED BOXES. WORK AND LICENSED IN THE STATE; OF OREGON. AND HANDLING IN BIDS. WIRING SPLICES ARE TO BE AVOIDED TO THE EXTENT POSSIBLE AND COLORING OF CABLES AND WIRING SHALL BE CONSISTENT 1.8 MAINTENANCE SERVICE 3.5 CONDUIT, BOXES, SUPPORTS, CABLING, AND WIRING SHALL BE THROUGHOUT THE ENTIRE SYSTEM AND FROM END-TO-END ON __ ___ ___ • PROVIDED BY E.C. E.C. SHALL SIZE ALL CONDUIT AND BOXES TO EACH AND EVERY CIRCUIT. MIXING AND/OR CHANGING COLORS ENGINEER A. PROVIDE SERVICE AND MAINTENANCE OF SPRINKLER MONITORING COMPLY WITH THE ELECTRICAL CODE. OF WIRING WILL NOT BE PERMITTED. EQUIPMENT FOR ONE YEAR FROM SYSTEM ACCEPTANCE. _.- n. C. SEPARATELY ZONE LIFE SAFETY DEVICES AND CONNECT TO THE PART 2 - PRODUCTS 3.6 INSTALLATION OF ALL NEW SYSTEM DEVICES AND COMPONENTS AND SPRINKLER MONITORING SYSTEM SO THAT THE SYSTEM REMOVAL AND/OR RELOCATION OF EXISTING DEVICES, INCLUDING OPERATION IS PERFORMED IN CONFORMANCE WITH BASE • ALL DEVICE TERMINATIONS AND MOUNTING, SHALL BE PROVIDED BY BUILDING STANDARDS. 2.1 APPROVED MANUFACTURERS THE E.C.. D. ALL EQUIPMENT SHALL BE HELD FIRMLY IN PLACE. FASTENING W A. MANUFACTURERS: AND SUPPORTS SHALL BE ADEQUATE TO SUPPORT THE LOADS �"'� ` ` 3.7 ALL DEVICE TERMINATIONS SHALL BE APPROVED BY THE AUTHORITY LJ..J HAVING JURSIDICTION WITH APPROPRIATE TERMINAL BOXES, WITH A SAFETY FACTOR OF FIVE 1. MATCH THE EXISTING BUILDING SPRINKLER (5). MONITORING SYSTEM MANUFACTURER. ENCLOSURES, ETC. E. WIRING SHALL BE CHECKED AND TESTED BY THE CONTRACTOR 2. SUBSTITUTIONS: NOT PERMITTED. IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED BY THE W 3.8 THE E.C. SHALL FIELD VERIFY AVAILABLE EXISTING SPRINKLER MANUFACTURER TO ASSURE THAT THE SYSTEM IS FREE OF < >, ,,0100 Ct 2.2 EXISTING SPRINKLER MONITORING CONTROL PANEL MONITORING RISER CAPACITY PRIOR TO BIDS. GROUNDS, OPENS, AND SHORTS. A. PROVIDE REQUIRED MODULES AND PROGRAMMING TO THE BASEO BUILDING SPRINKLER MONITORING SYSTEM AS REQUIRED FOR A. ALL SUBMITTALS AND FIRE DEPARTMENT INSPECTIONS SHALL BE F. AUTOMATIC DETECTOR INSTALLATION: CONFORM TO NFPA 72. CL) SCHEDULED IN ADVANCE AND BE EXECUTED EXPEDITIOUSLY TO C) -- EXTENSION/MODIFICATIONS TO THE EXISTING SYSTEM. MEET TENANT'S DATE OF OCCUPATION. 3.12 FIELD QUALITY CONTROL =='' CI . B. ALL FUNCTION AND DEVICE TESTING SHALL BE PERFORMED = C I 2.3 ALARM INITIATING DEVICES A. TEST IN ACCORDANCE WITH NFPA 72. r`�- AND/OR COORDINATED BY E.C. FOR A COMPLETE OPERATIONAL 0 A. SYSTEM SMOKE DETECTORS SHALL COMPLY WITH UL 268; SYSTEM AS OUTLINED BELOW (E.C. SHALL INCLUDE ALL OF THE B. TEST REPORT: A COMPLETE COMMISSIONING PACKAGE �. ..!J � OPERATING AT 24-V DC, NOMINAL. DETECTORS SHALL BE ASSOCIATED COSTS IN BIDS): INCLUDING LETTER OF SYSTEM. CERTIFICATION AND COPY OF , • TWO-WIRE TYPE. DETECTORS SHALL CONTAIN AN INTEGRAL ALL TEST REPORT DOCUMENTATION SHALL BE SUBMITTED ADDRESSABLE MODULE ARRANGED TO COMMUNICATE DETECTOR 1. ALL SYSTEM DEVICE TESTING, BALANCE, AND FUNCTION INDICATING PROPER INSTALLATION AND FUNCTIONING OF THE laull CO ilmi STATUS (NORMAL, ALARM, OR TROUBLE) TO SPRINKLER TESTS SHALL BE PROVIDED FOR ALL WORK INSTALLED SYSTEM, CONFORMANCE TO THE 'SPECIFICATIONS AND THAT THE L MONITORING CONTROL UNIT. DETECTOR AND ASSOCIATED AND MODIFIED WITHIN CONTRACT LIMITS OF COMPLETED SYSTEM IS IN OPERATING CONDITION AND ALL C') ELECTRONIC COMPONENTS SHALL BE MOUNTED IN A CONSTRUCTION, INCLUDING ADJACENT AREAS OUTSIDE OF COMPONENTS HAVE BEEN TESTED AND OPERATE TWIST-LOCK MODULE THAT CONNECTS TO A FIXED BASE. CONTRACT AREAS AFFECTED BY WORK IN THIS CONTRACT. SATISFACTORILY. THE TEST SHALL BE PERFORMED BY 0 "r"-- PROVIDE TERMINALS IN THE FIXED• BASE FOR CONNECTION TO 2. REPLACEMENT OF ALL DEFECTIVE AND/OR INSTALLED FACTORYTRAINED QUALIFIED TECHNICIANS. EACH AND EVERY CO BUILDING WIRING. DETECTORS DO NOT REQUIRE RESETTING OR MATERIALS, WIRING, COMPONENTS, AND DEVICES SHALL BE DEVICE SHALL BE TESTED AND THE CORRESPONDING DATED rte' READJUSTMENT AFTER ACTUATION TO RESTORE THEM TO PROVIDED BY E.C.. PRINTOUT FROM THE SYSTEM PRINTER DURING TESTING SHALL NORMAL OPERATION. DETECTORS SHALL CONTAIN AN INTEGRAL 3. E.C. SHALL PROVIDE ALL WRITTEN TEST REPORTS AND BE INCLUDED WITH THE SYSTEM.:TEST REPORT. VISUAL-INDICATING LIGHT OF LED 'TYPE, INDICATING DETECTOR SUBMIT TO BUILDING OWNER'S REPRESENTATIVE, C. MANUFACTURER SHALL GUARANTEE ALL SYSTEM EQUIPMENT FOR STATUS. UNLESS OTHERWISE INDICATED, DETECTORS SHALL BE ENGINEERS/ARCHITECTS, AND AUTHORITY HAVING A PERIOD OF ONE (1) YEAR FROM DATE OF FINAL ACCEPTANCE DIGITAL-ADDRESSABLE TYPE, INDIVIDUALLY MONITORED AT JURISDICTION. OF THE SYSTEM. SPRINKLER MONITORING CONTROL UNIT FOR CALIBRATION, 4. PROVIDE ALL NECESSARY INSTRUMENTATION AND SENSITIVITY, AND ALARM CONDITION. MONITORING. TEST EQUIPMENT. D. THE CONTRACTOR SHALL GUARANTEE ALL RACEWAYS AND WIRING B. PHOTOELECTRIC SMOKE DETECTORS SHALL HAVE DETECTOR 5. RE-PROGRAMMING OF SPRINKLER MONITORING SYSTEM BY TO BE FREE FROM INHERENT MECHANICAL OR ELECTRICAL ADDRESS ACCESSIBLE FROM SPRINKLER MONITORING CONTROL E.C. DEFECTS FOR ONE (1) YEAR FROM DATE OF FINAL ACCEPTANCE OF THE SYSTEM: UNIT AND SHALL BE ABLE TO IDENTIFY THE DETECTOR'S C. ALLOWANCES SHALL BE PROVIDED BY E.C. FOR ADDITIONAL LOCATION WITHIN THE SYSTEM AND ITS SENSISTIVITY SETTING. SPRINKLER MONITORING DEVICES AND INSTALLATION DUE TO E. COMPLETE SYSTEM TESTING AND DOCUMENTATION IN AN OPERATOR AT SPRINKLER MONITORING CONTROL UNIT, ADDITIONAL REQUIREMENTS FROM AUTHORITY HAVING ACCORDANCE WITH NFPA 72 IS REQUIRED AS PART OF THIS HAVING THE DESIGNATED ACCESS : LEVEL, SHALL BE ABLE TO JURISDICTION. SECTION. SUBMIT COMPLETED. AND SIGNED TEST REPORT IN 2 ISSUED FOR CONSTRUCTION 09.13.17 MANUALLY ACCESS PRIMARY STATUS, DEVICE TYPE, PRESENT QUANTITIES AS REQUIRED BY GENERAL CONDITIONS BUT NOT AVERAGE VALUE, PRESENT SENSITIVITY SELECTED, AND SENSOR LESS THAN FOUR (4) COPIES. UPON COMPLETION OF THE 1 ISSUED FOR BID/PERMIT 05.19.17 1 � v',EP q 3.9 EXAMINATION RANGE FOR EACH DETECTOR. INSTALLATION SPRINKLER MONITORING SYSTEMS A. VERIFY PRODUCTS AND SYSTEMS RECEIVING DEVICES ARE READY EQUIPMENT, THIS CONTRACTOR SHALL PROVIDE TO THE REV. DESCRIPTION DATE C. DUCT SMOKE DETECTORS SHALL. BE PHOTOELECTRIC TYPE FOR INSTALLATION. ARCHITECT/ENGINEER A COMPLETED NFPA 72 `RECORD OF COMPLYING WITH UL 268A. DETECTOR SHALL BE ACCESSIBLE ISSUES FROM SPRINKLER MONITORING CONTROL UNIT AND SHALL BE COMPLETION"AND A SIGNED WRITTEN STATEMENT, SUBSTANTIALLY ABLE TO IDENTIFY THE DETECTOR'S LOCATION WITHIN THE 3.10 EXISTING WORK IN FORM AS FOLLOWS: PHASE: SYSTEM AND SENSITIVITY SETTING. AN A. AREAS OF PRIOR TBID SUBMISSION AND "THE U UNDERSIGNED, HAVING ENGAGED AS THE CONSTRUCTION MONITORING CONTROL UNIT, HAVING THE INCLUDE IN BID PROPOSAL THEREPLACEMENTOFALL LIFE CONTRACTOR ON . THE (NAME OF PROJECT), ACCESS DESIGNATED PRIMARYESS LEVEL,STATUS, DEVICE BE TYPE,ABLE TO PRESENT MAVERAGE HAVE BEEENUALLY SAFETY �DESTROYEDCES H ORELOSTE NTENDED TO BE R DURING DEMOLITION.REUSED AND SYSTEM CONFIRMS THAT EQUIPMENTE WASINKL INSTALLEDR MONITORINGIN DOCUMENTS VALUE, PRESENT SENSITIVITY SELECTED, AND SENSOR RANGE ACCORDANCE WITH THE WIRING DIAGRAMS, PHASE FOR EACH DETECTOR. DETECTOR SHALL BE MOUNTED IN A B. REMOVE EXPOSED ABANDONED SPRINKLER MONITORING WIRING INSTRUCTIONS, AND DIRECTIONS PROVIDED." PHASE WEATHERPROOF DUCT HOUSING ENCLOSURE, NEMA 250, TYPE INCLUDING ABANDONED WIRING ABOVE ACCESSIBLE CEILING 4X, NTRL LISTED FOR USE WITH THE SUPPLIED DETECTOR FOR FINISHES. CUT CABLE FLUSH WITH WALLS AND FLOORS, AND F. AFTER RECEIPT OF THE TEST REPORT, COMPLETED RECORD OF SMOKE DETECTION IN HVAC SYSTEM DUCTS. EACH SENSOR PATCH SURFACES. COMPLETION FORM, AND WRITTEN STATEMENT, DEMONSTRATE SHEET DESCRIPTION: SHALL HAVE MULTIPLE LEVELS .OF DETECTION SENSITIVITY. C. REMOVE AND RELOCATE EXISTING SPRINKLER MONITORING THE OPERATION OF THE SYSTEM TO THE OWNER, ARCHITECT,SAMPLING TUBE DESIGN AND DIMENSIONS SHALL BE AS EQUIPMENT TO ACCOMMODATE THE NEW ARCHITECTURAL ENGINEER AND LOCAL CODE:°AUTHORITIES (AHJ). THE FINAL ELECTRICAL RECOMMENDED BY MANUFACTURER FOR SPECIFIC DUCT SIZE, MODIFICATIONS. ACCEPTANCE TEST SHALL INCLUDE COMPLETE TESTS AS AIR VELOCITY, AND INSTALLATION CONDITIONS WHERE APPLIED. REQUIRED TO SHOW COMPLIANCE WITH THESE SPECIFICATIONS SPECIFICATIONS D. DISCONNECT AND REMOVE ABANDONED SPRINKLER MONITORING AND STATE/LOCAL CODES. 2.4 IDENTIFICATION EQUIPMENT. E. MAINTAIN ACCESS TO EXISTING SPRINKLER MONITORING G. IN THE EVENT THE SYSTEM DOES NOT OPERATE PROPERLY, A. SPRINKLER MONITORING TERMINAL AND JUNCTION LOCATIONS CORRECTIONS SHALL BE MADE AND THE PROCEDURE REPEATED SHALL BE IDENTIFIED IN ACCORDANCE WITH NFPA 70. EQUIPMENT AND OTHER INSTALLATIONS REMAINING ACTIVE ANDFLOOR NO.: REQUIRING ACCESS. MODIFY INSTALLATION OR PROVIDE ACCESS UNTIL IT IS ACCEPTABLE TO THE ARCHITECT/ENGINEER AND JUNCTION AND TERMINAL BOXES SHALL BE PAINTED RED AND LOCAL AHJ. STENCILED " SPRINKLER MONITORING " PREVENTING PANEL. 1ST UNINTENTIONAL INTERFERENCE WITH THE SIGNALING CIRCUITS F. EXTEND EXISTING SPRINKLER MONITORING INSTALLATIONS USING 3.13 MANUFACTURER'S FIELD SERVICES DURING TESTING, SERVICING, AND ADDITIONAL MODIFICATIONS TO MATERIALS AND METHODS COMPATIBLE WITH EXISTING FLOOR THE SYSTEM. INSTALLATIONS OR AS SPECIFIED. A. INCLUDE SERVICES OF CERTIFIED TECHNICIAN TO SUPERVISE INSTALLATION, ADJUSTMENTS, FINAL CONNECTIONS, AND SYSTEM 2.5 WIRING • G. CLEAN AND REPAIR EXISTING SPRINKLER MONITORING TESTING. EQUIPMENT TO REMAIN OR TO BE REINSTALLED. Stole: Job Number: Y. A. ADDRESSABLE SLC'S NETWORK SHALL MATCH EXISTING STYLE - NONE 52322 WITH WIRE TYPE AS REQUIRED BY SYSTEM MANUFACTURER. H. EXISTING SPRINKLER MONITORING SYSTEM, POWER SUPPLIES , AND ASSOCIATED WIRING AND RACEWAY SHALL REMAIN ACTIVE North: Drown: DURING NEW CONSTRUCTION. AF PART 3 - EXECUTION E0 . 02 Chk'd: JS Flet O.te:3/91017 Foe N.,n,eg_ULdwq 1:\Option Care - Portland OR\Option Care - Portland OR\DWGS\CAD\Elec\eg_01.dwg 9/13/2017 12:08 PM kmchone Copyright ©2017 by Environmental Systems Design. Inc. ELECTRICAL SYMBOL LIST VV1L-i I T N E Y ARCHITECTS, INC. OCCUPANCY SENSOR SYSTEM LUMINAIRES ONE-LINE ELECTRICAL DIAGRAM ABBREVIATIONS AND DEFINITIONS 700 Commerce Drive I Suite 350 CEILING WALL NORMAL Oak Br+ook,IL60523 I USA � WALL SWITCH VACANCY SENSOR (DUAL TECHNOLOGY) --< INCOMING LINE AFF ABOVE FINISHED FLOOR T : 630.571.1118 I F : 630.571.0518 F 1 ATS AUTOMATIC TRANSFER SWITCH Whitney-architects.com 0 1 CEILING MOUNTED DUAL TECHNOLOGY 360' VACANCY 30 2X4 LED LIGHTING FIXTURE —II0 GROUND SENSOR WITH POWER PACK AS REQUIRED - — BB BASEBOARD HEATER IL. CORPORATE LIC, 1 84-001 580 o 4" DOWNLIGHT FIXTURE BREAKER-(3-POLE UNO) CB CIRCUIT BREAKER c--s) CEILING MOUNTED DUAL TECHNOLOGY 360' OCCUPANCY ~ CCT CIRCUIT - SENSOR WITH POWER PACK AS REQUIRED LED LINEAR PENDANT FIXTURE N'-- SINGLE THROW SWITCH CO CONDUIT ONLY ESQ LED SUSPENDED LINEAR FIXTURECT CURRENT TRANSFORMER EnvronmentaISystemsDesign,lnc. SWITCHES 0 REVENUE METER CUH CABINET UNIT HEATER 175 west Jackson Bvd.Suite 1400 Chicago,Illinois 60604 r o 7" DOWNLIGHT PENDANT 312 372 1200 fax 312 372 1222 SINGLE POLE SWITCH. THE NUMBER '1DENOTES DISC DISCONNECT vw.esdglobal.com DPR License No.184-000892 IL CIRCUIT NUMBER AND THE LETTER 'a' 10SWITCH CONTROL 0 DECORATIVE PENDANT DISTRIBUTION EQUIPMENT DN DOWN 'WP' DENOTES WEATHERPROOF EM EMERGENCY '2P' DENOTES 2-POLE o LED SUSPENDED LINEAR FIXTURE Aim_ FLUSH MOUNTED PANEL. SEE DESCRIPTION FOR TYPE. EPO EMERGENCY POWER OFF '3W' DENOTES 3-WAY Q DECORATIVE PENDANT SURFACE MOUNTED PANEL. SEE DESCRIPTION FOR EQPT EQUIPMENT #f1~ VS MANUAL ON FOR VACANCY SENSOR .. TYPE. EUH ELECTRIC UNIT HEATER • 4" WALL WASHER IBI IBI PLUG-IN BUSWAY, SIZE AND MOUNTING AS INDICATED. EWC ELECTRIC WATER COOLER ENGINEER 44 OS AUTO ON FOR OCCUPANCY SENSOR - FA FIRE ALARM 1 ® LIGHTING CONTROL STATION - LUTRON SEETOUCH iim1X4 LED LIGHTING FIXTURE FCU FAN COIL UNIT 'XXX' IS UNIQUE IDENTIFIER REFER TO SCHEDULE VOICE I DATA SYSTEM FPB FAN POWERED BOX LED LINEAR STRIP LIGHTING FIXTURE DIMMER SWITCH pI DATA OUTLET - WALL MOUNTED FFC FORCED FLOW CONVECTOR V5 D 'VS' INDICATES INTEGRAL MANUAL UN 1=0'RC VACANCY /1 LED TROFFER FIXTURE GFI GROUND FAULT INTERRUPTER w SENSOR ASSOCIATED WITH DIMMER © FLUSH MOUNTED DATA FLOOR CORE DEVICE EMERGENCY 1 GRD GROUND 1_U D FLOOR CORE DEVICE WITH WHIP FOR DATA FEED TO HID HIGH INTENSITY DISCHARGE Z FIRE ALARM SYSTEM F1 1x3 LED LIGHTING FURNITURE 1:: w FIXTURE WITH 90-MINUTE EMERGENCY HP HORSEPOWER DD DUCT SMOKE DETECTOR EM1 BATTERY PACK. JUNCTION BOX WITH WHIP FOR TELE/DATA FEED TO JB JUNCTION BOX < Ct FURNITURE DOWNLIGHT WITH 90-MINUTE EMERGENCY IG ISOLATED GROUND C.) Q HEATING EQUIPMENT BATTERY PACK. INC INCANDESCENT 0 RECEPTACLES = Q 4' LINEAR LED PENDANT LIGHTING KV KILOVOLT = CV r�/ FPB -- FAN POWERED BOX FIXTURE WITH 90MINUTE EMERGENCY DUPLEX RECEPTACLE KW KILOWATT L�— BATTERY PACK.i. 0 Q LUMINAIRE NOTES: MM.= DOUBLE DUPLEX RECEPTACLE KVA KILOVOLT AMP • � .' EXHAUST FAN - REFER TO SCHEDULES FOR ® 'F1 ' DENOTES FIXTURE TYPE, REFER TO LIGHTING LED LIGHT EMITTING DIODE — HORSEPOWER AND VOLTAGE FIXTURE SCHEDULE FOR DESCRIPTION AND --- - -_- MOUNTING. � DUPLEX RECEPTACLE ON SEPARATE CIRCUIT LTG LIGHTING 12.. L.0 ® 0 ' ELECTRIC WATER HEATER — REFER TO SCHEDULES '3a' '3' DENOTES THE CIRCUIT NUMBER AND 'a' MCB MAIN CIRCUIT BREAKER FOR WATTAGE AND VOLTAGE DENOTES SWITCH CONTROL. FURNITURE MOUNTED DUPLEX RECEPTACLE MAIN LUGS ONLY 0N— MLO— 'EMI ' 'EM' DENOTES A LIGHT FIXTURE WITH 90-MINUTECD EMERGENCY BATTERY PACK. :EE FURNITURE MOUNTED DOUBLE DUPLEX RECEPTACLE MTD MOUNTED r-- MOTORS AND CONTROLS NIC NOT IN CONTRACT MOTOR, REFER TO EQUIPMENT SCHEDULE FOR FURNITURE MOUNTED DEDICATED DUPLEX RECEPTACLE NTS NOT TO SCALE /10/ HORSEPOWER, DESCRIPTION, WIRING AND PANEL FED FROMEXIT SIGN SCHEDULE Q JUNCTION BOX PNL PANEL _ Di NON-FUSED DISCONNECT SWITCH, SHADED QUADRANTS ON SYMBOL INDICATE FACE ORIENTATION - PRI PRIMARY RATING AS INDICATED II JUNCTION BOX WITH ELECTRICAL WHIP TO FURNITURE RCP REFLECTED CEILING PLAN SINGLE FACE DOUBLE FACE , 21-1 FUSIBLE DISCONNECT, RATING AS INDICATED SEC SECONDARY QUADRUPLEX FLOOR CORE FLUSH MOUNTED --T CODE No. DESCRIPTION SYMBOL CODE No. DESCRIPTION SYMBOL SPD SURGE PROTECTION DEVICE (TVSS) COMBINATION MOTOR CONTROLLER AND DISCONNECT SWITCH WITH OVERCURRENT PROTECTION I I d ELECTRICAL FLOOR CORE WITH WHIP TO FURNITURE ST SHUNT TRIP 1 FIRE ESCAPE 1 16 i FIRE ESCAPE . 2 ISSUED FOR CONSTRUCTION 0913.17 0 EQUIPMENT IDENTIFICATION — SES: E �_..... ....._._.. SW SWITCH , EQUIPMENT SCHEDULE i PP POWER POLE 1 ISSUED FOR BIDIPERMIT 05.19.17 — -- -- - -- 2 STAIRS ® 17 STAIRS e TEL TELEPHONE SINGLE POLE MANUAL STARTER WITH THERMAL ct P OVERLOAD PROTECTION FOR FRACTIONAL SINGLE PHASI RECEPTACLE NOTES: TR TAMPER RESISTANT REV. DESCRIPTION DATE 2T MOTORS. 'P' DENOTES PILOT LIGHT, '2' DENOTES 3 EXIT 18 EXIT 'CFI' DENOTES GROUND FAULT INTERRUPTER UH UNIT HEATER DOUBLE POLE, AND 'T' DENOTES THERMAL OVERLOAD SC DENOTES SEPERATE CIRCUIT ISSUES 4 FIRE ESCAPE 19 FIRE ESCAPE UNO UNLESS NOTED OTHERWISE PHASE: `-- I UPS UNINTERUPTABLE POWER SUPPLY MISCELLANEOUS COMBINATION DEVICES CONSTRUCTION 5 STAIRS ® 20 STAIRS m VP VAPOR PROOF (ENCLOSED AND GASKETED) HDMI CONNECTION - FLUSH MOUNTED FLOOR CORE DEVICE WITH WHIP DOCUMENTS --- 6 EXIT 21 EXIT iO f FOR POWER/DATA FEED TO FURNITURE WP WEATHERPROOF (NEMA-3R OUTDOOR, CABLE CONNECTION -- -- NEMA-4 IN PLENUMS) PHASE -- - 7 FIRE ESCAPE 22 FIRE ESCAPE DUPLEX FLOOR BOX FLUSH MOUNTED FOR El AV CONNECTION \/� POWER/TELE/DATA WH WATER HEATER 8 STAIRS ® 23 STAIRS m .-- (NEMA-4) SHEET DESCRIPTION: WT WATERTIGHT NEMA-4 SECURITY — 1 _ ; QUADRUPLEX FLOOR BOX FLUSH MOUNTED FOR XFMR TRANSFORMER ELECTRICAL 9 EXIT 24 EXIT ��0 POWER/TELE/DATA ® J-BOX FOR CARD READER XP EXPLOSION PROOF SYMBOLS LIST -t-- PB PUSH BUTTON 10 FIRE ESCAPE WIREMOLD SURFACE DEVICE FOR POWER/DATA VFC VARIABLE FREQUENCY CONTROLLER . RECEPTACLE 11 STAIRS ® 1 FLOOR NO.: .--. 12 EXIT Ell1ST BATTERY PACK FLOOR 11 FIXTURES WITH NUMBER OF SEALED BEAM HEADS SHOWN Scale: Job Number: i NONE 52322 North: Drown: C h k'd: E O . J3 AF JS Not Oat.l/9iMI 7 FSI,Nat,'. gIawq l:\Option Core - Portland OK\Option Care - Portland OR\DWGS\CAD\Elec\eg_01 -dwg 9/13/2017 12:08 PM kmchone Copyright 0 2017 by Envronrnentol Systems Design. Inc. -- BUILDING EXTERIOR TENANT SPACE WHITNEY ARCHITECTS, INC, 700 Commerce Drive I Suite 350 Oak Brook,IL 60523 I USA T: 630.571.1118 1 F : 630.571.0518 whitney-architects.com X X- X .r. XX X X-X-X-X-X -Xxr-XXX- X-X X--X -X X-X XX-X -X -X -X X-X X X-X X-X X- X X X-X X-X X-X> EX-X - . X-X-X-X-X-XX X x-x>E-)(x-x x-x IL. CORPORATE LIC. 1 84-001 580 rx-xxl<hix_x_x*:_x_x)0(x_xx_x*xx-xx_x x-xx_xx.xx_xx_xx_xx_xx_f T x x x E---------0 XI XIGEX. ,I,X ,iry.-x x.-x _ RD. )f• X X X X , , - EXISTING WALL MOUNTED JX 4C .. X Environmental Systems Design,Inc. TRANSFORMER X X ,IX 175 West Jackson Blvd.Suite 1400 15KVA v4C -X X-X X-X X X X X X X '--X X-X X-X X---X X-X X-X X-X XE XEX-)EX-X-*E-X312* ' Chicago,Illinois 60604 372 1200 fax 312 372 1222 480-240/120V X .esdglobal.com 3PH. 4*-x-x x x x x-x--x-x-x x x>pe<x-x x-x x-x x-x 3 X X >\ x ,t, rx www DPR License No.1134-000892 IL x, ___, r 1 x, _x_ x x x I- -I x rx4 xif i -F-- -1 I 1 T -1 EXISTING X METER = I I I X X 400A 277/480V I I I I X X X I I 1 I 3PH. 4W. X X X [---1 X I I EXISTING EXISTING I la I L _ ENGINEER - -- , )00L L J J DISC. H3 • DISC. H I -, 100AS/100AF • 200AS/200AF x___><J L L 1 L, I EXISTING EXISTING EXISTING x 277/480V 277/480V EXISTING EXISTING EXISTING 1 PANEL L1S1 PANEL H3 PANEL H2* 3PH. 4W.I I 3PH. 4W. PANEL L2 PANEL L1 PANEL H1 100A MLO 100A MLO 277/480V 100A MCB* 277/480V* • 120/240V 200A MCB 200A MCB 120/208V 277/480V I 3PH. 4W. 3PH. 4W. 3PH. 4W. X _ _I - _ _ _L - 7 3PH. 4W. I - ---1Z-1 3PH.120/?08V 4W. 3PH. 4W. J LLI X X X X X EXISTING 400A PGE METER TAP I T -1 EX. . I BOX 480/277V 3 PH, 4W 1 I 6-- - -- D1-1-1 . agZ EXISTING Of ILU TRANSFORMER I DEMO RISER NOTES: ' 75KVA DEMO RISER DIAGRAM < >.,„,.r• 480-208/120V 1. COORDINATE ANY POWER SHUT DOWNS WITH THE LEGEND § NOT TO SCALE 3PH. 4W. LANDLORD, GC, CLIENT AND ALL AFFECTED TENANTS 2 (..) n NEW WIRING _ ,-. WEEKS PRIOR TO SHUT-DOWN. COORDINATE WITH .. NEW EQUIPMENT UTILITY COMPANY AS REQUIRED. = M - - - - - EXISTING EQUIPMENT2. RELOCATE POWER FEED ON EXISTING PANEL 'L2' TO = CNI f2 .. , --x-x-x-x-x-x-x-x-x- EXISTING TO BE REMOVED EXISTING GAS WATER HEATER AND CIRCUIT TO NEW C) PANEL "LlAI CCT.#21. - 3. E.C. SHALL RELOCATE EXISTING TO REMAIN EQUIPMENT AS REQUIRED TO SPARES IN EXISTING PANELS. EXTEND WIRING AND CONDUIT AS REQUIRED. Clan U") C7) BUILDING EXTERIOR ELEC ROOM 134 UPS ROOM 149 WAREHOUSE VESTIBULE 133 ELEC 131 0 CO 129 N-- NEW 4#4/0 & NEW 3116, & 1#6GRD., NEW 4#1 & - I 1#10GRD., 2-1/2"C. 1#8GRD., 1-1/2"C. \ NEW 4#1 & 1#8GRD., 1-1/2"C. i 1 3 ISSUED FOR CONSTRUCTION 09.13.17 Iv A, si 2 ISSUED FOR PERMIT REVISIONS 09.1117 V 1 ISSUED FOR BIDIPERMIT 05.19.17 NEW 41/2/0 REV. DESCRIPTION DATE I I St_.al#6GRD., 1 , r 1 44/ Tr 1 NEW NEW ISSUES NEW FEXISTING1 NEW NEW NEW 2 E . EXISTING PNL 1 PANEL H3 I PNL UPS-1 20KVA UPS PNL PH ' EXISTING I NEW EXISTING EXISTING 1.--- --- --- --- --- -- EXISTING EXISTING PNL L 1 A PNL Ll B PHASE: A METER GEN-DP 1 I 100A MLO 80A MCB 480V- 150A MCB I PANEL H2 DISC. H2 DISC. H3 DISC. H1 1 PANEL L1 j PANEL H1 I ,' 100A MLO 100A MLO 1 100A MCB 200A MCB I 2297°7A/4M8OCVB I NEW 400A 400A MCB 120/208V 120/208V 120/208V . .; 132p0H/.2048wV. 132p0H/.2048wV. ,is, 4 , I ,: N L E NV LV Eli- NV L EV I 277/480V I I 277/480V I 100AS/100AF 100AS/100AF 200AS/200AF CONSTRUCTION 277/480V 480/277V BP BP _agg......9.01?... -*BP ..E3111 - I 3PH. 4W. I --. 3PH. 4W. 3PH. 4W. 3PH. 4W. v I 120/208V GENERATOR 480/277V 3PH. 4W. 3PH. 4W. 0 NO 'NO NO 0 NO I (SEE E0.10 NEW 150A 1 3PH. 4W. 277/480V 277/480V 277/480V 1 3PH. 4W. 1 3PH. 4W. 1 I I I DOCUMENTS (SEE E0.11 FOR DETAILS) 1- -1 , NC NO NC NO NC NO ,i _____1 __DETAILS) \___1208/120V 1 i • N___I \\___, ., •-' L 3PH 4W. L... L __I L __I I PHASE • L7i N L E N L E NEW ATS-1 200A 480/277V 3PH. NEW ATS-2 100A 480/277V / 3PH. 4W., S/N N L NEW ATS-3 100A 480/277V / . NEW 4#1 & 1#8GRD., , 1-1/2"C. NEW 3#4 & 1#8GRD., I I I I • II SHEET DESCRIPTION: NEW 4#3, NEW 4//2/0 -' ist & 1#8GRD., ELECTRICAL ___I _11- - -1 I (SEE EOM FOR (SEE EOM FOR (SEE EOM FOR 1-1/4"C. & 2"C. ()..... #6GRD, 3/4"C. T DETAILS) DETAILS) DETAILS) RISER DIAGRAM - TO BLDG GRD r EXISTING 400A PGE METER TAP I r ._1 -"--- ..._. _ _ _ --1 EX. BOX 480/277V 3 PH, 4W EXISTING -7 4-GRD. 17= -_- NEW 45KVA XFMR INCOMING SERVICE LOAD SCHEDULE - DEMAND LOADS 480V-208/120V 3PH 4W TRANSFORMER RISER NOTES: 75KVA FLOOR NO.: LOAD TYPE DEMAND KVA DEMAND AMPS 0 /5 ELECTRICAL RISER DIAGRAM 480-208/120V 1. ALL DEMOLITION AND NEW WORK SHALL BE COORDINATED 1ST 480/277V 3PH. 4W. WITH GC AND BUILDING. COORDINATE ANY POWER SHUT-- NEW 2 SETS 4#4/0 & II& NOT TO SCALE 1#3GRO., 2-1/2"C. EACH RECEPTACLES 50.5 60.8 DOWNS WITH THE BUILDING, GC, CLIENT AND ALL AFFECTED TENANTS 2 WEEKS PRIOR TO SHUT-DOWN. COORDINATE WITH FLOOR (REFER TO EOM FOR DETAILS) LIGHTING & 8 UTILITY COMPANY AS REQUIRED. .. 5162.3 CONTINUOUS . 2. PROVIDE PULL BOXES AND CABLE SUPPORTS AS REQUIRED. MOTORS 10.9 13.2 Scale: Job Number: NONE 52322 MISCELLANEOUS & 110.9 133.5 North: Drown: NON-CONTINUOUS AF TOTAL 224.1 269.8 Chled: E0 . 04 JS T:\Option Core - Portland OR\Option Core - Portland OR\DWGS\CAD\Elec\eg_01.dwg 9/13/2017 12:09 PM kmchone Copyright ©2017 by Environmental Systems Design. Inc. PANELBOARD SCHEDULE (EXISTING) PANELBOARD SCHEDULE \'\IIFI I T N E Y DESIGNATION: L1 MAIN TYPE: 200A MB MOUNTING: EXISTING BRANCH OCP TYPE: EXISTING DESIGNATION: L1A MAIN TYPE: MLO MOUNTING: SURFACE . CH 6 P TYP. : MOLI i CAS /B VOLTAGE: 208Y/120 MAIN OPTIONS: - ENCLOSURE: EXISTING FAULT DUTY: EXISTING VOLTAGE: 208Y/120 MAIN OPTIONS: - ENCLOSURE: NEMA 1 FAULT DUTY: 10KAIC A ARCHITECTS, INC. 3PH 4W BUS AMPS: 225A NEUTRAL BUS: EXISTING INTEGRAL SPD: - 3PH 4W BUS AMPS: 225A NEUTRAL BUS: 100% RATED INT .:AL NO 700 Commerce Drive I Suite 350 PANEL OPTIONS: - GROUND BUS: EXISTING OWNER METERS: NONE ACCESSORIES: - PANEL OPTIONS: - GROUND BUS: YES OWNER METERS: NONE ACCESSORIES: - Oak Brook,IL 60523 I USA OCP OCP OCP OCP T : 630.571.1118 I F : 630.571.0518 NO. DESCRIPTION OCP SIZE OPTIONS A B C A B C OPTIONS OCP SIZE DESCRIPTION NO. NO. DESCRIPTION OCP SIZE OPTIONS A B C . A B C OPTIONS OCP SIZE DESCRIPTION N0. whitney-architects.com t EXISTING CONF 135/136/137 - 1,260 6,360 2" V RM 107/108 GEN REC 20A - 900 180 - 20A CORRIDOR GEN REC 2 - 3 EXISTING CONE 138/139/140 20A - 1,260 6,773 * 100A PANEL L1B 4 ' BREAKRM 107 TV REC 20A - 180 500 - 20A COPY/PRINT PRINT REC 4' IL. CORPORATE LIC. 184-001580 5 •' RECEPTION 101 GEN REC 20A - 540 6,373 `6 _ 5 SPARE 20A - 1300 - 20A COPY/PRINT COPIER E' 7 N TMNT RM 103/104 GEN REC 20A - 720 - 20A SPARE 8 T CONFERENCE 108 TV REC 20A - 720 - 20A SPARE 8 9 SPARE 20A - - 20A SPARE _ 10 9 „r CONFERENCE 108 TV REC 20A - _ 360 360 - 20A OPEN OFFICE 106 GEN REC 10 11' OFFICE 134 GEN REC 20A - 180 696 * 15A EF-1.05 1,2' 11 SPARE 20A - 540 - 20A UPS 120/121 GEN REC 12' OS-0 13 EXISTING WATER HEATER 20A - 1,500 1,680 - 20A BREAKRM 107 COFFEMAKER 14 1'Z' WELLNESS 109 GEN REC 20A - 180 - 20A SPARE 14 15 SPARE 20A - 1,680 I - 20A BREAKRM 107 COFFEMAKER 't'6 15✓ WELLNESS 109 MICROWAVE 20A - 1,100 1,300 - 20A WAREHOUSE 111 COPIER 16 Environmental Systems Design,Inc 17✓ WATING 102 GEN REC 20A - 360 600 - 20A BREAKRM 107 FRIDGE 18'' 17`. WELLNESS 109 FRIDGE 20A - 156 1 180 - 20A WAREHOUSE 111 TV REC 18'' 175 West Jackson Blvd.Suite 1400 19 SPARE 20A * 1,200 - 20A EX BREAKRM DISHWASHER 20 19'J RESTRM 115/116 GEN REC 20A - 360 180 - 20A STORAGE 133 GEN REC 20 ' Chicago,Illinois 60604 312 372 1200 fax 312 372 1222 21 SPARE 20A * 396 * 15A UH-1.02 22' 21 EXISTING GAS HEATER 20A - 500 720 - _ 20A VESTIBULE 113/114/124 REC 22 www.esdglobal.com DPR License No. 184-000892 IL 23" TREATMENT 103/104 TV REC 20A * 360 - 20A SPARE 24 23" RM 123/111 GEN REC 20A - 360 540 - 20A STORAGE 133 GEN REC 24 _ 25" TREATMENT 103/104 GEN REC 20A - 360 - 20A SPARE 26 _ 25/ MDF 119 GEN REC 20A - 1,080 720 - 20A STORAGE 133 GEN REC 26 27' RESTROOM 105 GEN REC 20A - 180 - 20A SPARE 28 27,r WAREHOUSE 111 GEN REC 20A - 900 90 * 15A RP-1 28 29 SPARE 20A - 600 * 20A BREAKRM 107 ICEMAKER 3Q/ 29/ WAREHOUSE 111 GEN REC 20A - 360 - 20A SPARE 30 31./ 7,400 1,020 * 20A BREAKRM 107 FRIDGE 32/ 31./ WAREHOUSE 111 FREEZER 20A - 1,260 - 20A SPARE 32 33✓ PANEL L1A 100A * 8,570 720 - 20A OPEN OFFICE 106 GEN REC 3.4 33,E WAREHOUSE 111 FREEZER 20A - 1,260 - 20A SPARE 34 3Y 6,556 500 36 35✓ WAREHOUSE 111 GEN REC 20A - 720 1100 - 20A BREAKRM 107 MICROWAVE 3fi 37 SPARE 20A - 500 - 20A EXISTING SPLIT UNIT 38 37" WAREHOUSE 111 GEN REC 20A - 720 1,100 - 20A BREAKRM 107 MICROWAVE 38 39 ' SPARE 20A - _ 500 40 39 SPARE 20A - 1,300 - 20A BREAKRM 107 VENDING 40 20A EXISTING HVAC UNIT - - - ENGINEER 41 EXISTING RECIRC PUMP 20A - '00 500 42 41 SPARE 20A - 1300 - 20A BREAKRM 107 VENDING 42 Total 11,240 10,010 8,096 10,760 10,069 9,269 Totol Total 5,220 4,300 1,596 2,180 4,270 4,960 Total TOTAL PHASE A: 22,000 VA TOTAL CONNECTED LOAD: 59.4 kVA TOTAL PHASE A: 7,400 VA TOTAL CONNECTED LOAD: 22.5 WA TOTAL PHASE B: 20,079 VA 165.0 AMPS TOTAL PHASE B: 8,570 VA 62.5 AMPS TOTAL PHASE C: 17,365 VA TOTAL DEMAND LOAD: 50.4 kVA TOTAL PHASE C: 6,556 VA TOTAL DEMAND LOAD: 16.3 kVA 139.8 AMPS V3.6 , 45.3 AMPS V3.6_ W NOTES: 1) '*' IN 'OCP OPTIONS' = PROVIDE NEW BREAKER. EXISTING SPARE OCPs CAN BE UTILIZED IF IN GOOD CONDITION AND SAME RATING. ILI p QIL1 PANELBOARD SCHEDULE PANELBOARD SCHEDULECt DESIGNATION: L1B MAIN TYPE: MLO MOUNTING: SURFACE BR•1 •.: • . . + i 9 4. DESIGNATION: UPS-1 MAIN TYPE: 80A MB MOUNTING: SURFACE :RANO SCP •E: MS.• I C • .... ..11 O VOLTAGE: 208Y/120 MAIN OPTIONS: - ENCLOSURE: NEMA 1 FAULT DUTY: IOKAIC VOLTAGE: 208Y/120 MAIN OPTIONS: - ENCLOSURE: NEMA 1 FAULT DUTY: 10KAIC C) c:, • e 3PH 4We '1 3PH 4W BUS AMPS: 225A NEUTRAL BUS: 100% RATED INTEL L SPD NO BUS AMPS: 225A NEUTRAL BUS: 100% RATED I GRAL D. N• PANEL OPTIONS: - GROUND BUS: YES OWNER METERS: NONE ' ESSI' S: - PANEL OPTIONS: - GROUND BUS: YES OWNER METERS: NONE ACCESSORIES: - Q 1 Cy ��// NO. DESCRIPTION OCP SIZE OCP A B C A I B C OCP OCP SIZE DESCRIPTION NO. NO. DESCRIPTION OCP SIZE OCP A B C A B C OCP OCP SIZE DESCRIPTION NO. L.L. OPTIONS OPTIONS OPTIONS OPTIONS `'1 ROOFTOP GEN REC 20A - 900 ' 720 - 20A OPEN OFFICE 106 GEN REC ' 41 1,, OFFICE 134/135/138 PC REC 20A - 540 180 1 - 20A RECEPTION 101 PC REC 20 AC-1.02 15A _ 146 720 OPEN OFFICE 106 GEN REC 4/ 3" OPEN OFFICE 106 PC REC 20A - 360 180 - 20A WAREHOUSE 11.1 PC REC 4 ii C.D 5/ 146 720 20A OPEN OFFICE 106 GEN REC 61 5/ OPEN OFFICE 106 PC REC 360 540 - 20A PHARMACY PREP 125 PC REC 6 _ w 7 SPARE 20A - 720 OPEN OFFICE 106 GEN REC 8/ 7' OPEN OFFICE 106 PC REC 20A - 360 1,500 - 20A MDF ROOM L5-20R b (f, F. CU-1.02 15A _ 947 720 _ 20A OPEN OFFICE 106 GEN REC 10, 4' OPEN OFFICE 106 PC REC 360 1,500 - 20A MDF ROOM L5-20R 10 Q "r7)11../ 947 360 OPEN OFFICE 106 GEN REC 12., 11/ OPEN OFFICE 106 PC REC - 360 500 - 20A MDF ROOM SECURITY 1? �, 13 SPARE 20A - _ 720 - OPEN OFFICE 106 GEN REC 14.,/ 13' OPEN OFFICE 106 PC REC 20A180 - 20A SPARE 14 0 15' CONDENSATE PUMP 20A - 100 720 20A OPEN OFFICE 106 GEN REC 16, 15,, OPEN OFFICE 106 PC REC - 360 - 20A SPARE 16 r wVAV DIFFUSER XMFR 20A - 600 720 20A OPEN OFFICE 106 GEN REC 18✓ 17,./ OPEN OFFICE 106 PC REC 20A 360 - 20A SPARE 18 QC) 1VAV DIFFUSER XMFR 20A - 600 720 _ OPEN OFFICE 106 GEN REC 20' 19,./ OPEN OFFICE 106 PC REC - 360 - 20A SPARE 20 �- - 21' RM 130/131/132 GEN REC 20A - 900 720 - 20A OPEN OFFICE 106 GEN REC 2/ 21,E OPEN OFFICE 106 PC REC 20A360 - 20A SPARE 22 23 PASS THRU 131 GEN REC 20A - 720 720 OPEN OFFICE 106 GEN REC 24,E 23/ OPEN OFFICE 106 PC REC20A _ _ 360 - 20A SPARE 24 26 PASS THRU 131 GEN REC 20A - 540 720 _ OPEN OFFICE 106 GEN REC 26/ 25✓ OPEN OFFICE 106 PC REC 360 - 20A SPARE 26 27 COLLAB 132 TV REC 20A - 360 720 20A OPEN OFFICE 106 GEN REC 2a,, 27✓ OPEN OFFICE 106 PC REC 20A 360 - 20A SPARE 28 29 SPARE 20A - 720 OPEN OFFICE 106 GEN REC 30,/ 2' ' OPEN OFFICE 106 PC REC 360 - 20A SPARE 30 31 SPARE 20A - 720 -' 20A OPEN OFFICE 106 GEN REC 34' `131 OPEN OFFICE 106 PC REC 20A - 360 - 20A SPARE 32 , 33 SPARE 20A - _ 720 _ OPEN OFFICE 106 GEN REC 3A/ 31 OPEN OFFICE 106 PC REC 360 - 20A SPARE 34 35 SPARE 20A - 720 20A OPEN OFFICE 106 GEN REC 36. 35 _ OPEN OFFICE 106 PC REC 20A - 360 - 20A SPARE 36 37 SPARE 20A - - 20A SPARE 38 *7 _ OPEN OFFICE 106 PC REC 360 - 20A _ SPARE 38 39 SPARE 20A - - 20A SPARE 40 39 SPARE 20A - - 20A _ SPARE 40 41 SPARE 20A - - 20A SPARE 42 41 SPARE 20A - - 20A SPARE 42 3 ISSUED FOR CONSTRUCTION 09.13.17 Total 2,040 2,453 2,413 4,320 4,320 3,960 Total Total 2,520 L 2,160 2,160 1,680 1,680 1,040 Total 2 ISSUED FOR PERMIT REVISIONS 09.13.17 TOTAL PHASE A: 6,360 VA TOTAL CONNECTED LOAD: 19.5 WA TOTAL PHASE A: 4,200 VA TOTAL CONNECTED LOAD: 11.2 kVA 1 ISSUED FOR BID/PERMIT 05.19.17 TOTAL PHASE 8: 6,773 VA 54.1 AMPS TOTAL PHASE B: 3,840 VA 31.2 AMPS TOTAL PHASE C: 6,373 VA TOTAL DEMAND LOAD: 16.5 kVA TOTAL PHASE C: 3,200 VA TOTAL DEMAND LOAD: 11.2 kVA REV. DESCRIPTION DATE 45.8 AMPS V3.6 31.2 AMPS V3.6 ISSUES PHASE: CONSTRUCTION DOCUMENTS PHASE SHEET DESCRIPTION: PANEL SCHEDULES FLOOR NO.: 1ST FLOOR Scale: Job Number: NONE 52322 North: Drawn: AF E0 . 05 Chk'd: JS viol Osre.3!§/eoi 7 Fi5!Niml.eg-Ol y..g : •p ion are - 'or Ion. •' •p an ore - -or on. •' 2 ' • I ec eg_I ..wg • I :p• 'Y kmchone Copyright © 2017 by Environmental Systems Design. Inc. PANELBOARD SCHEDULE (EXISTING) PANELBOARD SCHEDULE (EXISTING) WHITNEY DESIGNATION: H1 MAIN TYPE: 200A MB MOUNTING: EXISTING BRANCH OCP TYPE: EXISTING DESIGNATION: H2 MAIN TYPE: 100A MB MOUNTING: EXISTING BRANCH OCP TYPE: EXISTING VOLTAGE: 480Y/277 MAIN OPTIONS: - ENCLOSURE: EXISTING FAULT DUTY: EXISTING VOLTAGE: 480Y/277 MAIN OPTIONS: - ENCLOSURE: EXISTING FAULT DUTY: EXISTING ARCHITECTS, INC. 3PH 4W BUS AMPS: 225A NEUTRAL BUS: EXISTING INTEGRAL SPD: - 3PH 4W BUS AMPS: 100A NEUTRAL BUS: EXISTING INTEGRAL SPD: • - PANEL OPTIONS: - GROUND BUS: EXISTING OWNER METERS: NONE ACCESSORIES: - PANEL OPTIONS: - GROUND BUS: EXISTING OWNER METERS: NONE ACCESSORIES: - 700 Commerce Drive I Suite 350 OCP OCP OCP E� OCP Oak Brooke IL 60523 I USA NO. DESCRIPTION OCP SIZE A B C A B C OCP SIZE DESCRIPTION NO. NO. DESCRIPTION OCP SIZE A B C I A B C OCP SIZE DESCRIPTION NO. T : 630.571.1118 I F : 630.571.0518 OPTIONS OPTIONS OPTIONS 11 OPTIONS 1 2,77:1 _ 1,110 - 20A ENCLOSED LTG 2 1 3,297 I 10,294 Whitney-architects.com 3 EXISTING RTU 15A - 2,775 1,485 - 20A ENCLOSED LTG 4 3 EXISTING RTU 20A - 3,297 7,694 a 70A PANEL PH 4/ IL. CORPORATE LIC. 1$4-0 01 5$Q 5 2,775 2786 - 20A ENCLOSED LTG 6 5 3,297 9,856 6✓ 7 1,717 - 20A OPEN AREA LTG 8 7 2,993 • 20A SPARE 8 9 SPARE 20A - 165 LOCK* 20A EXIT SIGNS 10 9 _ EXISTING RTU 20A - 2,993 • 20A SPARE 10 11 4500 - 20A EXISTING WATER HEATER 12 11 2,993 12 13 4,330 4,330 14 13 - 15A SPARE 14 [E� 15 EXISTING RTU 20A -- 4,330 4,330 - 20A EXISTING RTU 16 15 SPARE 20A - 16 Environmental Systems Design,Inc �p"�_ W ��4..'1a►�����\�� ' 17 - SPACE 18 19 4,330 * 20A SPARE 20 Total 6,290 6,290 6,290 ` 10,294 7,694 9,856 Total 175 West Jackson Blvd.Suite 1400 Chicago,Winos 60604 21 EXISTING RTU 20A - 4,330 * 20A SPARE 22 312 372 1200 fax 312 372 1222 www.esdgkibal.com 23 4,330 * 20A SPARE 24 TOTAL PHASE A: 16,584 VA TOTAL CONNECTED LOAD: 46.7 kVA DPR License No.184-000892 it_ 25 22,000 4,654 26' TOTAL PHASE B: 13,984 VA 56.2 AMPS 27 PANEL EX TRANS TO L1 100A - 20,079 4,654 * 20A RTU-1.10 aaTOTAL PHASE C: 16,146 VA TOTAL DEMAND LOAD: 43.7 kVA 29 17,365 4654 30/ 52.5 AMPS V3.6 31 SPACE - - SPACE 32 A33 SPACE _ - SPACE 34 NOTES: 1) ''' IN 'OCP OPTIONS' = PROVIDE NEW BREAKER. EXISTING SPARE OCPs CAN BE UTILIZED IF IN GOOD CONDITION AND SAME RATING, 35 SPACE SPACE 36 37 SPACE - - SPACE 38 39 SPACE - - SPACE 40 PANELBOARD SCHEDULE 41 SPACE -- - SPACE 42 DESIGNATION: GEN-DP MAIN TYPE: 400A MB MOUNTING: SURFACE BRANCH OCP TYPE: MOLDED CASE C/B EN ,NEED Total 33,435 31,514 28,800 11,811 10,634 116,2701 1 Total VOLTAGE: 480Y/277 MAIN OPTIONS: - ENCLOSURE: NEMA 1 FAULT DUTY: 42KAIC 3PH 4W BUS AMPS: 400A NEUTRAL BUS: 100% RATED INTEGRAL SPD: NO PANEL OPTIONS: - GROUND BUS: YES OWNER METERS: NONE ACCESSORIES: - TOTAL PHASE A: 45,246 VA TOTAL CONNECTED LOAD: 132.5 kVA TOTAL PHASE B: 42,148 VA 159.3 AMPS NO. DESCRIPTION OCP SIZE OCP OPTIONS A B C A B C OCP OPTIONS OCP SIZE DESCRIPTION NO. TOTAL PHASE C: 45,070 VA TOTAL DEMAND LOAD: 123.4 kVA ,4 45,246- 20,454 2. 148.4 AMPS V3.6 3v PANEL H1 200A - 42,148 20,094 - 100A PANEL H3 4 NOTES: 1) '*' IN 'OCP OPTIONS' = PROVIDE NEW BREAKER. EXISTING SPARE OCPs CAN BE UTILIZED IF IN GOOD CONDITION AND SAME RATING. 45,070 25,454 6 7 16,584 - SPACE 8 LLID 9'/ PANEL H2 100A - 13,984 - SPACE - 10 Z 11 16,146 - SPACE 12 13 SPACE - - SPACE 14 - PANELBOARD SCHEDULE (EXISTING) 15 SPACE - - SPACE 16 r DESIGNATION: H3 MAIN TYPE: MLO MOUNTING: EXISTING BRANCH OCP TYPE: EXISTING 17 ' SPACE - - SPACE 18 VOLTAGE: 480Y/277 MAIN OPTIONS: - ENCLOSURE: EXISTING FAULT DUTY: EXISTING Total 61,830 56,132 61,216 20,454 20,094 25,454 Total � 3PH 4W BUS AMPS: 225A NEUTRAL BUS: EXISTING INTEGRAL SPD: - CD n a.. PANEL OPTIONS: - GROUND BUS: EXISTING OWNER METERS: NONE ACCESSORIES: - TOTAL PHASE A: 82,284 VA TOTAL CONNECTED LOAD: 245.2 kVA Z Q OCP OCP NO. DESCRIPTION OCP SIZE OPTIONS A B C A B C OPTIONS OCP SIZE DESCRIPTION NO. TOTAL PHASE B: 76,226 VA 294.9 AMPS Z cy 1__L 1 5,013 4,200 . TOTAL PHASE C: 86,670 VA TOTAL DEMAND LOAD: 224.2 kVA r----3 EXISTING RTU 30A - 5,013 3,840 * 50A PANEL UPS-1 4/ 269.6 AMPS V3.6 Q 5 5,013 3,200 6' - 0 7 3,241 2,000 GENERATOR EXISTING RTU 30A - 3,241 2,000 - 30A GENERATOR ACCESSORIES 18/ PANEL r�+n J t 1 3 241 2000 PANEL 1 PANELBOARD SCHEDULE DESIGNATION: PH MAIN TYPE: 150A MB MOUNTING: SURFACE BRANCH OCP TYPE: MOLDED CASE C/B CL Lr) 13 I SPACE - 6,000 * 30A CUH-1.02 14' VOLTAGE: 208Y/120 MAIN OPTIONS: - ENCLOSURE: NEMA 1 FAULT DUTY: 42KAIC d7 15 I SPACE - 6,000 * 30A CUH-1.03 18' 3PH 4W BUS AMPS: 225A NEUTRAL BUS: 100% RATED INTEGRAL SPD: NO 0 "l- -Til CUH-1.01 30A * 6,000 6000 * 30A CUH-1.04 18/ PANEL OPTIONS: - GROUND BUS: YES OWNER METERS: NONE ACCESSORIES: - Total 8,254 8,254 14,254 12,200 11,840 11,200 Total OCP OCP 'rk- NO. DESCRIPTION OCP SIZE OPTIONS A B C A B C OPTIONSOCP SIZE DESCRIPTION NO. TOTAL PHASE A: 20,454 VA TOTAL CONNECTED LOAD: 66.0 kVA 1 SPARE 20A1 .- 720 - 20A CLEAN RM #1 HOOD CO'S 2 TOTAL PHASE B: 20,094 VA 79.4 AMPS 3.,/ PHARM/PREP PP CO'S 20A - 360 960 - 20A CLEAN RM #1 HOOD CO'S 4✓ TOTAL PHASE C: 25,454 VA TOTAL DEMAND LOAD: 66.0 kVA 5 SPARE _ 20A - 720 - 20A CLEAN RM #1 HOOD CO'S 6v 79.4 AMPS V3.6 7s/ PHARM/PREP PP CO'S 20A - 360 960 - 20A CLEAN RM #1 HOOD CO'S 8 9" PHARM/PREP PP CO'S 20A - 360 720 - 20A CLEAN RM #1 HOOD CO'S 10 NOTES: 1) '*' IN 'OCP OPTIONS' = PROVIDE NEW BREAKER. EXISTING SPARE OCPs CAN BE UTILIZED IF IN GOOD CONDITION AND SAME RATING. 11 PHARM/PREP PP CO'S 20A - 720 960 1 CLEAN RM #1 HOOD CO'S 12 13 PHARM/PREP PP CO'S 20A - 360 720 MA CLEAN RM #1 HOOD CO'S 14/ 15 SPARE 20A - 960 - 20A CLEAN RM #1 HOOD CO'S 16.-- 17 PHARM/PREP PP CO'S 20A - 360 720 - 20A CLEAN RM #1 HOOD CO'S 19v PHARM/PREP PASS THRU CLR 20A - 900 960 - MA CLEAN RM #1 HOOD CO'S 1 3 ISSUED FOR CONSTRUCTION 09 13.17 21/ SPARE 20A - 1 1 . CLEAN RM #1 HOOD CO'S 22 23`' SPARE 20A - •s 1 1 CLEAN RM #1 HOOD CO'S ISSUED FOR PERMIT REVISIONS 09.13.17 A 25 SPARE 20A - SPARE 26 27, PHARM/PREP CO'S 20A 360 .1 1 CLEAN RM #1 CO'S 28 1 ISSUED FOR BID/PERMIT 05.19.17 29 PHARM/PREP CO'S 20A - 180 720 - 20A ANTE RM #2 CO'S zpJJ 31✓ PHARM/PREP COOLER 20A - 900 900 - 20A NPR RM HOOD CO REV. DESCRIPTION DATE 3' PHARM/PREP COOLER 20A - 900 •1 - 1 j' 1CO 34,, ISSUES 35. - PHARM/PREP PASS THRU CLR 20A - 900 11 20A NPR RM FRIDGE36,E 37 PHARM/PREP PASS THRU CLR 20A - 900 900 - 20A MOTORIZED 1f.; 38/ PHASE: 3$' EF-1 ON ROOF 20A LOCK 900 • 1 - 20A VIDEO '1 40' 44, PHARM/PREP LIGHTING 20A - 1,136 1440 - 20A4 CONSTRUCTION 43' PHARM/PREP/CLN RM LIGHTING 20A - 994 720 - 20A ANTE/NPR ROOM 4,4 45/ ANTE/NPR LIGHTING 20A - 284 - 20A SPARE 46 DOCUMENTS 47/ PHARM/PREP PP CO'S 20A - 540 - 20A SPARE 48 49✓ SPARE 20A - - 20A SPARE50 PHASE 51 SPARE 20A - - 20A SPARE 52 53 SPARE 20A - - 20A SPARE 54 55 SPARE 20A - - 20A SPARE 56 SHEET DESCRIPTION: 57 SPARE 20A - - 20A SPARE 58 59 SPARE 20A - - 20A SPARE 61 61 SPARE 20A - - 20A SPARE • 63 SPARE 20A - - 20A SPARE •• PANEL 65 SPARE 20A - - 20A SPARE •• SCHEDULES 67 SPARE 20A - - 20A SPARE •: 69 SPARE 20A - - 20A SPARE 70 71 SPARE 20A - - 20A SPARE 72 FLOOR NO.: 73 74 75 76 1ST 77 78 79 - 80 FLOOR 81 82 /1 83 84 Total 4,414 3,164 3,836 5,880 1 4,530 16,020 Total Scale: Job Number: 52322 NONE TOTAL PHASE A: 10,294 VA TOTAL CONNECTED LOAD: 27.8 kVA TOTAL PHASE B: 7,694 VA 77.3 AMPS North: Drown: TOTAL PHASE C: 9,856 VA TOTAL DEMAND LOAD: 24.8 kVA AF E O . O 68.8 AMPS V.3.6 Chk'd: 6 NO ES: P EL SCH DULE OWN F R REF ENCS II NLY. R FER TO ANGST OM CIFt INGS FIIR ADD IONAL DETAILS. is ooxe 7l,laai 'k+lame e9.01 6vg T:\Option Core - Portland OR\Option Core - Portland OR\DWGS\CAD\Elec\eg_01 .dwg 9/13/2017 12:09 PM kmchone Copyright © 2017 by Environmentol Systems Design. Inc. WALL MOUNTED - VACANCY / OCCUPANCY SENSORS - DUAL TECH - LINE VOLTAGE (NOTE #1, #2) LIGHTING FIXTURE SCHEDULE (NOTE #1 ) WHITNEY ' MANUFACTURER SINGLE RELAY DUAL RELAY NOTES `- DIMMABLE COOPER ONW-D-1001 -MV-WH ONW-D-1001-DMV-WH NUMBER OF WATTAGE OF TYPE OF TOTAL WATTS WATTAGE CONTROLS LOAD ARCHITECTS, INC. HUBBELL LH-MT-S-1-W LH-MT-0-2-W TYPE DESCRIPTION LAMPS LAMPS LAMPS USED VOLTAGE PLENUM RESTRICTION ( /Y N AND TYPE REMARKS LEVITON ODS 15-TD LABEL 700 Commerce Drive I Suite 350 TYPE) Oak Brook,1L 60523 I USA LUTRON MS-6102-WH MS-B202-WH F1 a 2X4 1 31 .8 LED 31 .8 W 277 Y N Y(0- 1 OV) LED NOTE#4,5 T : 630.571.1118 I F : 630.571.0518 PHILIPS LRS--2220-OW LRS-2225—OW whitney-architects.com SENSOR SWITCH WSX-PDT(-SA)-WH WSX-PDT-2P(-2SA)-WH F1 b NOT USED 1 27.1 LED 27.1 W 277 Y N Y(0- 10V) LED - NOTE#4,5 WATTSTOPPER DSW-301 -W DSW-302-W F2 4" DOWNLIGHT 1 25.4 LED I 25.4 W 277 Y N Y(0-10V) LED IL, CORPORATE LIC. 1 84-001 580 F4 4' SUSPENDED LINEAR 1 58 LED 58 W 277 N N Y(0- 10V) LED NOTE#4,5 NOTES: F6 NOT USED 1 6 LED 6 W 277 N N N LED 1. SENSORS SHALL FUNCTION AS MANUAL ON UNLESS NOTED OTHERWISE ON PLAN. LED TROFFER 1 71 LED 71 W 277 N N Y(0- 10V) LED NOTE#2 -- • 2. COLOR SHALL BE AS SELECTED BY ARCHITECT. FOR COLORS OTHER THAN WHITE, REPLACE -W EXIT EXIT SIGN 24 - LED 5 W 277 Y N N LED NOTE#3 (I = ...9____- ,-) OR -WH WITH PROPER COLOR CODE. NOTES: Environmental Systems Design,Inc, 1 . REFER TO ARCHITECTURAL SCHEDULE FOR SPECIFIC INFORMATION, INCLUDING MANUFACTURER, MODEL NUMBER, COLORS, FINISHES, TRIMS, AND CEILING TYPES. _-- ,,,� 175 West Jackson Blvd.Suite 1400 CEILING MOUNTED - SENSORS AND DIMMING Chicago,Illinois 60604 312 372 1200 fax 312 372 1222 MANUFACTURER OCCUPANCY SENSOR POWER PACK SWITCH TYPE NOTES (NOTE #4) 2. REFER TO ANGSTROM AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL DETAILS. www.esdglobal.com DPR License No. 184-600892 IL nLIGHT nCM-PDT-10-RJB nPP16-D nPODM-SA-DX-WH NOTE #1 _ 3. PROVIDE 90 MINUTE BATTERY BACKUP BALLAST AS REQUIRED. ALL EXIT SIGNS SHALL HAVE 90 MINUTES OF BATTERY BACKUP. , WATTSTOPPER LMDC-100 LMRC-211 €2i13i LMDM-101 NOTE #1, #2 4. PROVIDE FIXTURE WITH EMERGENCY BATTERY PACK OPTION WITH MINIMUM 90 MINUTE RUNTIME ONLY FOR FIXTURES DESIGNATED AS EMERGENCY ON PLAN. LEVITON OSC2O-MOW MZD30-101 RLVSW-4LW NOTE #1 __ LUTRON LRF2-OCR2B-P-WH RMJ-5T€S8T -DV-B PJ2-3BRL-GWH-L01 NOTE #1, #3 . 5. FIXTURES MARKED AS EMERGENCY SHALL BE PROVIDED WITH PHILIPS BODINE EMERGENCY LIGHTING DRIVER IN ADDITION TO 0- 10V DRIVER. NOTES: 1. SENSORS SHALL FUNCTION AS MANUAL ON UNLESS NOTED OTHERWISE ON PLAN. LIGHTING CONTROLS NARRATIVE (NOTE #1) 2. UTILIZE 1 OR 2 OR 3 BASED ON NUMBER OF ZONES WITHIN ROOM. 3. UTILIZE S8T WHEN USING 5 AMPS OR ABOVE, UP TO A MAXIMUM OF 8 AMPS. LOCAL CONTROL AUTOMATIC CONTROL OTHER ENGINEER — 4. VERIFY DIMMING TYPES SPECIFIED. DIMMING LISTED IS FOR 0-10 VOLT DIMMING. VERIFY POWER PACK NEEDED FOR OTHER SWITCHED (5) MANUAL ON (M) DIMMING TYPES. LOCAL DIMMED (D) 50% PARTIAL SENSOR (S) WALL BI-LEVEL (B) AUTO ON (50) TIME (T) MANUAL ON / AUTO ON SWITCHES CONTROL MULTI-SCENE 100% AUTO ON NONE (N) DAYLIGHTING SWITCH STYLE (NOTE #1, #2) ROOM TYPE (Y/N) DIMMING (M) (100) BOTH SENSOR St TIME (B) (Y/N) MANUFACTURER POLES NOTES TOGGLE DECORATOR / INSERT ELEC Y S M N N ALL LIGHTS TURN ON AND OFF VIA A LOCAL SWITCH CONTROL. w LEVITON 1081-W 56081-w 1 POLE NO AUTOMATIC CONTROL SHALL BE PROVIDED. LU D GENERIC MOMENTARY COOPER AH1995W N/A 1 POLEMfi � z CONTACT HUBBELL HBL-1557-W N/A 1 POLE CONFERENCE RMr:tr..�..I PASS & ,SEYMOUR 1081-W TM-870-STM-W-CC-6 1 POLE ALL LIGHTS TURN ON AND OFF VIA A LOCAL SWITCH CONTROL. COOPER N/A GMDS-W 1 POLE HUBBELL N/A LVSM-#-NP-WH 1 TO 4 POLES JANITORS,PHONE ROOM, A TREATMENT,STORAGE, , AIS, THE LOCAL SWITCH CONTROL MUST BE PRESSED UPON ENTRY C: - Y S M S N TO TURN ON THE LIGHTS. A LOCAL VACANCY SENSOR SHALL Q O LEVITON N/A 000LVS-#-W 1 TO 10 POLES WELLNESS, COLLAB AREA, TURN OFF ALL LIGHTS WITHIN THE ROOM UPON VACATING THE CD • MANUFACTURER SPECIFIC PHILIPS N/A ITSMSW 1 POLE UPS, STORAGE, MDF ROOM. � (NOTE #1) SENSOR SWITCH N/A sPODm(-SA)-WH 1 POLE NOTE #3, #4 Z 0 Ct SENSOR SWITCH N/A sPODm-2P(-2SA)-WH 2POLE NOTE #3, #4 ",......„/N....._..../ 11111.111" Wr W. (NI SENSOR SWITCH N/A sPODm-3X(-SA)-WH 1 POLE, 3 WAY NOTE #3, #4 0 I� cl N A LVSW-10 -W 1 WATTSTOPPER / # TO 8 POLES ALL LIGHTS ARE DIMMABLE AND CONTROLLED VIA A LOCAL DIMMING CONTROL. THE LOCAL DIMMING CONTROL MUST BE NOTES: PRESSED UPON ENTRY TO TURN ON THE LIGHTS. A LOCAL Ill CO I- 1. TOGGLE OR DECORATOR STYLE SHALL BE AS SELECTED BY THE ARCHITECT. VACANCY SENSOR SHALL TURN OFF ALL LIGHTS WITHIN THE 0...• 2. COLOR SHALL BE AS SELECTED BY ARCHITECT. FOR COLORS OTHER THAN WHITE, REPLACE -W OR -WH WITH PROPER COLOR CODE. ROOM UPON VACATING THE ROOM. EMERGENCY LIGHTING WITHIN 1-r) 3. COMPATIBLE ONLY WITH SENSOR SWITCH SENSORS. OPEN OFFICE, RECEPTION Y D M S N ROOM SHALL BE CONTROLLED VIA OCCUPANCY SENSOR AND 0) WIRED AHEAD OF SWITCH. THE LOCAL OCCUPANCY SENSOR 0 r- 4. SUFFIX -SA OR -2SA REQUIRED FOR MANUAL ON OPERATION. SHALL TURN ON ALL EMERGENCY LIGHTS WITHIN THE ROOM CO UPON ENTRY AND TURN OFF UPON VACATING THE ROOM. N--- DURING LOSS OF POWER, EMERGENCY LIGHTING SHALL TURN CEILING MOUNTED - VACANCY / OCCUPANCY SENSORS (NOTE #1) - DUAL TECH - LOW VOLTAGE FULL ON. MANUFACTURER MODEL POWER PACK SWITCH TYPE NOTES COOPER OAC-DT-2000-R SP-20-MV GENERIC OR SPECIFIC HUBBELL OMNI-DT-2000 UVPP(-M) GENERIC OR SPECIFIC NOTE #3 LEVITON OSC20-MOW OSP20-RDH GENERIC OR SPECIFIC LUTRON LOS-CDT-2000-WH PP-DV(-M) GENERIC OR SPECIFIC NOTE #3 ALL LIGHTS TURN ON AND OFF VIA A LOCAL SWITCH CONTROL. -- - - PHILIPS LRM-2255-O0 LCA2292 GENERIC OR SPECIFIC A LOCAL OCCUPANCY SENSOR SHALL TURN ON ALL LIGHTS SENSOR SWITCH CM-PDT-10 PP-20 SPECIFIC NOTE #2 • WITHIN THE ROOM UPON ENTRY AND TURN OFF UPON VACATING WATTSTOPPER DT-300 BZ-150 GENERIC OR SPECIFIC MEN'S/WOMEN'S THE ROOM. EMERGENCY/NIGHT LIGHTING WITHIN ROOM SHALL BE RESTROOMS, VESTIBULES, Y S 100 S N CONTROLLED VIA OCCUPANCY SENSOR AND WIRED AHEAD OF 2 ISSUED FOR CONSTRUCTION 09.13.17 CORRIDORS SWITCH. THE LOCAL OCCUPANCY SENSOR SHALL TURN ON ALL NOTES: EMERGENCY/NIGHT LIGHTS WITHIN THE ROOM UPON ENTRY AND 2 ISSUED FOR PERMIT REVISIONS 09.13.17 1. SENSORS SHALL FUNCTION AS MANUAL ON UNLESS NOTED OTHERWISE ON PLAN. TURN OFF UPON VACATING THE ROOM. DURING LOSS OF 2. WHERE SENSOR SWITCH SENSORS ARE UTILIZED, SENSOR SWITCH SWITCHES ARE REQUIRED. POWER, EMERGENCY LIGHTING SHALL TURN FULL ON. 1 ISSUED FOR BID/PERMIT 05.19.17 3. SUFFIX -M REQUIRED FOR MANUAL ON OPERATION. REV. DESCRIPTION DATE ISSUES PHASE: ALL LIGHTS TURN ON AND OFF VIA A LOCAL SWITCH CONTROL, THENT TOETURNAON WITCH LIGOTSROAL LOCAL VVACANCYSSEENSORMUST BE PRESED UPONSHALLRY CONSTRUCTION TURN ROOM. o MERGENCYFF ALL HTS L GHTINGNTHE WITHINROOM ROOMUPON SHALL BE VACATING THE DOCUMENTS BREAKROOM, WAREHOUSE Y S M S N CONTROLLED VIA OCCUPANCY SENSOR AND WIRED AHEAD OF SWITCH. THE LOCAL OCCUPANCY SENSOR SHALL TURN ON ALL PHASE EMERGENCY LIGHTS WITHIN THE ROOM UPON ENTRY AND TURN OFF UPON VACATING THE ROOM. DURING LOSS OF POWER, EMERGENCY LIGHTING SHALL TURN' FULL ON. SHEET DESCRIPTION: LIGHTING NOTES: 1 . CONTROL WIRING MAY BE RUN IN THE SAME RACEWAY OR ENCLOSURE AS POWER WIRING ONLY AS PERMITTED BY THE AHJ. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE SCHEDULES FOR OBTAINING ANY VARIANCES OR SPECIAL PERMISSIONS REQUIRED FOR RUNNING CONTROL WIRING IN THE SAME RACEWAY OR ENCLOSURE AS POWER WIRING. FLOOR NO.: 1ST FLOOR Scale: Job Number: NONE 52322 North: Drown: Chkd E0 . 07 JS woc one 3/91/CI7 lie Name eg_61.J.. 7:\Option Care — Portland OR\Option Core — Portland OR\DWGS\CAD\EIec\eg_01.dwg 9/13/201 / 12:09 PM kmchone Copyr;ght © 2017 by Environmental Systems Design. Inc. WHITNEY GENERAL LIGHTING CONTROL SYSTEM SCHEDULE (NOTE #1 ) CONTROL TYPE AUTOMATIC ARCHITECTS, INC. SWITCH BUTTON CONTROL GROUP (NOTE #3) PANEL CIRCUIT (SWITCHING OR LOAD TYPE DAYLIGHTING SCHEDULE REMARKS 700 Commerce Drive I Suite 350 TAG (NOTE #4) Oak Brook,IL 60523 I USA DIMMING) (NOTE #5) T : 630.571.1118 I F : 630.571.0518 1ST FLOOR whitney-archltects.com 1 OPEN OFFICE 110 1 L1A 8o DIMMING LED NO NOTE #6 NOTES # 2,3 A 2 OPEN OFFICE 110 2 L1A 8b DIMMING LED NO NOTE #6 NOTES # 2,3 IL. CORPORATE LIC. 1 84-001 580 R/L RAISE LOWER NOTE #8 1 OPEN OFFICE 110 1 L1A 8a DIMMING LED NO NOTE #6 NOTES # 2,3 B 2 OPEN OFFICE 110 2 L1A 8b DIMMING LED NO NOTE #6 NOTES # 2,3 Ci--i--0 3 CORRIDOR 137/138/142 L1A 8c _ SWITCHING LED NO NOTE #7 NOTES # 2,3 R/L RAISE LOWER NOTE #8 Envlronmenta systems Design,Inc. 1 OPEN OFFICE 110 1 L1A 8a DIMMING LED NO NOTE #6 NOTES # 2,3 175 West Jackson Blvd.Suite 1409 6004 C 2 OPEN OFFICE 110 2 L1A 8b DIMMING LED NO NOTE #6 NOTES # 2,3 312372c12001fax 3123721222 orn R/L RAISE LOWER NOTE #8 vicen a No.184- 00 DPR License No.184-000892 IL 1 RECEPTION 102 1 L1A 8d DIMMING LED NO NOTE #6 NOTES # 2,3 - D 2 RECEPTION 102 2 L1A 8e DIMMING LED NO NOTE #6 NOTES # 2,3 R/L RAISE LOWER NOTE #8 E 1 CORRIDOR 137/138/142 L1A 8c SWITCHING LED NO NOTE #7 NOTES # 2,3 NOTES: 1 . PROVIDE LUTRON, WATTSTOPPER, CRESTRON, LEVITON OR ACUITY BRAND SYSTEM. SYSTEM SHALL BE FEED THRU MODULE SYSTEM. FURNISH AND INSTALL ALL NECESSARY COMPONENTS FOR A COMPLETE AND OPERATIONAL SYSTEM. REFER TO SCHEDULES FOR QUANTITY OF 277V 20A RATED POLES. LIGHTING CONTROLS TO ENGINEER MEET THE FOLLOWING CRITERIA: - 277 VOLT INPUT - DIMMING MODULES SHALL BE 0-10V DIMMING COMPATIBLE. 2. OVERRIDE SWITCHES: PROVIDE SWITCH WITH NUMBER OF BUTTONS TO MATCH NUMBER OF CONTROLLED CIRCUIT SWITCH LEGS INDICATED ABOVE. SWITCH SHALL w HAVE FINISH AS SELECTED BY THE ARCHITECT. Lll D . z 3. PROVIDE ENGRAVED FACEPLATES AND BUTTONS DESIGNATING THE AREA OF CONTROL OF EACH CONTROL STATION PER ENGRAVING SCHEDULES. ENGRAVING f I-I SCHEDULES SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE WITH THE OWNER AND ARCHITECT. n/ I..L Q O 4. LOAD INFORMATION IS FOR CONVEYANCE OF DESIGN BASIS ONLY. CONTRACTOR SHALL VERIFY TYPE, QUANTITY, AND CIRCUIT NUMBERS WITH PLANS AND Q ARCHITECTURAL PLANS. 5. LIGHTING ZONE SHALL BE CONTROLLED VIA LOCAL AUTOMATIC DAYLIGHT SENSOR AND WALL CONTROL STATION WITH RAISE LOWER SWITCH. THE DAYLIGHT SENSOR = CNI ca SHALL NOT BE OVERRIDDEN. EXACT LIGHT LEVELS SHALL BE CONFIRMED IN FIELD PRIOR TO PROGRAMMING (RECORDED A MINUMUM OF 1 HOUR PRIOR TO SUNRISE OR A MINIMUM OF 1 HOUR AFTER SUNSET) UNLESS EXPLICITLY DELINEATED BY THE ARCHITECT ON THE DRAWINGS. THIS SHALL BE CONFIRMED FOR EACH 0 UNIQUE SPACE TYPE. 6. LIGHTS SHALL BE CONTROLLED VIA LOCAL VACANCY SENSOR WITH MANUAL ON / AUTOMATIC OFF. i- CI) I- 7. LIGHTS SHALL BE CONTROLLED VIA LOCAL OCCUPANCY SENSOR WITH AUTO ON / AUTOMATIC OFF. �, 8. RAISE / LOWER BUTTONS SHALL CONTROL THE ACTIVE SCENE ONLY. CI14) 0x-- CD x- 2 ISSUED FOR CONSTRUCTION 09.13.17 1 ISSUED FOR BID/PERMIT 0519:17 REV. DESCRIPTION DATE ISSUES PHASE: CONSTRUCTION DOCUMENTS PHASE SHEET DESCRIPTION: LIGHTING SCHEDULES FLOOR NO.: 1ST FLOOR Scale: Job Number: NONE 52322 North: Drown. AF E0 . 08 Chk'd. JS oc Dace.379RMI 7 c .It Naar cg_D.deel T:\Option Care — Portland OR\Option Care — Portland OR\DWGS\CAD\Elec\eq_O1 .dwq 9/13/2017 12:09 PM kmc one Copyright © 2017 by Environmental Systems Design. Inc. WHITNEY ARCHITECTS, INC. 700 Commerce Drive I Suite 350 Oak Brook,IL 60523 I USA T : 630.571.1118 I F : 630.571.0518 whitney-architects.com IL. CORPORATE LIC. 1 84-001 580 ESD Environmental Systems Design,Inc 175 West Jackson Blvd.Suite 1400 Chicago,Illinois 60604 312 372 1200 fax 312 372 1222 www.esdglobal.corn DPR License No. 184-000892 IL ENGINEER LII WI D \ Qiii ALL UPS DIMENSIONS, BREAKER SIZES, DIAGRAMS AND FEEDER SIZES BASED ON \ APC MGE GALAXY 3500 UPS SYSTEM. LIEBERT NX UPS IS ACCEPTABLE AS WELL. QCD CONTRACTOR SHALL INCLUDE ALL NECESSARY PRICING IN BIDS FOR LIEBERT NX UPS Q SHOULD IT BE SELECTED AND SHALL SUBMIT ALL MODIFICATIONS TO ENGINEER IN WRITING. PROVIDE ALL REQUIRED BREAKERS AND FEEDER SIZES. Z C) N VCT FLOORING BONDING NOTES: 0 1. CONTRACTOR SHALL MOUNT 4"X4" JUNCTION V SYSTEM BONDING JUMPER BOX ON WALL AT FLOOR LEVEL. INSERT FOIL Or) GROUNDING STRIP INTO BOX. INSIDE JUNCTION (PROVIDED BY APC) I BOX, BOND FOIL TO TENANT GROUND BAR L17) SYSTEM GROUNDING BUS WITH DEDICATED #6 GROUND WIRE IN 3/4"C. CY) DO NOT LEAVE FOIL EXPOSED. I 0 MIB E.C. (REFER TO RISER I CO 5,07CO I3p o) DIAGRAM) 480/277V, 30, 3W+GND NEW 1 #6GRD., o 3/4"C. TOIo 30KVA NEW 3#6, 1 #10GRD., 1 "C. VCT BONDING DETAIL EXISTING BUILDING 480/208VAC BY APC • GRD. (BY E.C.) NOT TO SCALE I ‘....A.,_./..._.A..../J I I _i_ v I • NEW 4#1 & 1 #6G RD., - I 1 - 1/2"C. ---------,, I • SBP o • I 01 0) aI UNINTERRUPTIBLE POWER SOURCE (UPS) - MDF ROOM a. 8X40 LED DISPLAY ON FRONT OF ENCLOSURE. 1. MANUFACTURER: THE LCD SHALL DISPLAY UPS STATUS, METERING, . APC MGE GALAXY 3500 2 ISSUED FOR CONSTRUCTION 09.13.17 NEW 4#3 & 1 #8GRD. 0 1. MANUFACTURER: BATTERY STATUS, ALARM/EVENT QUEUE, ACTIVE b. LIEBERT NX I a. APC MGE GALAXY 3500 ALARMS AND UPS CONFIGURATIONS. THE FRONT ISSUED FOR BID/PERMIT 05.19.17 • 1 1 -1/4"C. b. LIEBERT NX UPS PANEL DISPLAY SHALL SHOW A SYSTEM MIMIC 2. THREE BREAKER MAINTENANCE BYPASS: MOLDED CASE DIAGRAM WITH AN OUTLINED POWER PATH, CIRCUIT BREAKERS WITH MICROPROCESSOR CONTROLLED TRIP UNITS AND AUXILLARY CONTACTS. REV. DESCRIPTION DATE I XR BATTERY L L L L UPS ca I 2. FRONT ACCESSIBLE, TOP FEED INPUT AND OUTPUT CURRENT OPERATING MODE AND EVENT LOGS. ENCLOSURES AS T T T- T T • 3. INPUT VOLTAGE: 480/277V, 3 PHASE, 4 WIRE PLUS 1) ALARMS: 3. KIRK KEY INTERFACE: PROVIDE DETAILED WRITTEN ISSUES I REQUIRED T ,, MES I GROUND 1) INPUT FAILURE SEQUENCE OF OPERATION AND LOCATE IN BYPASS PHASE: 07°} 07°} 07°} 47°) ---4 i • 3P 2) OVER TEMPERATURE CABINET. I - I I 4. OROUND VOLTAGE: 208/120V, 3 PHASE, 4 WIRE PLUSG3) FAN FAILURE 4. UPS SHALL HAVE 200% RATED BUS CONSTRUCTION : ] � 4) SYSTEM SUMMARY OF LAST 64 DOCUMENTS I - - - - I 5. OUTPUT CAPACITY: 20KVA WITH 0.9 POWER FACTOR EVENTS 6. BATTERY RUN-TIME: 12 MINUTES 10. FACTORY START-UP: PROVIDE FACTORY START-UP TEST PHASE / I NEW 4#3 & 1 #8GRD., I 7. CONTACTS: PROVIDE 2 NO NC AUXILLARY CONTACTS FOR FORMS AND TEST PROCEDURES FOR REVIEW BY FOUR USER DEFINED VARIABLES. ENGINEER. I• 1 -1/4"C. FIELD START-UP: PROVIDE FIELD START-UP SERVICES 11 . SHEET DESCRIPTION: 1 8. COMMUNICATION: PROVIDE WITH GATEWAY CARD FOR WEB 02 } 03 P • ENABLED REAL TIME MONITORING. ITERFACE TO BE AND STANDARD START-UP COMMISSIONING TESTS. UPS RISER I v I MODBUS RTU PROTOCOL PRO IIDEEGE PORTABLE LOAD BANK FOR FULL LOAD TE— • 9. FRONT DISPLAY PANEL: DIAGRAM & I NEW 4#3 & 1 #8GRD., I 12. PEOPLE.TRAINING: PROVIDE FOUR HOURS OF TRAINING FOR FOUR DETAILS 1 - 1/4"C. UPS SYSTEM OUTPUT I 208V, 30, 4 WIRE + GROUND I MAINTENANCE BYPASS MODULE - MDF ROOM UPS FLOOR NO.: • TO PANEL UPS- 1 I (SEE RISER DIAGRAM E0,04 FOR DETAILS) I 1ST 1 UPS RISER DIAGRAM & DETAILS NOT TO SCALEFLOOR Scale: Job Number: NONE 52322 North: Drown: AF Chkd: — EO . 1O JS me Name e�0,.ew 3:\Option Care - Portland OR\Option Core - Portland OR\DWGS\CAD\Elec\eg_01 .dwg 9/13/201 / 12:09 PM kmchone Copyright p 2017 by Environmental Systems Design. Inc. WHITNEY . ARCHITECTS, INC. 700 Commerce Drive I Suite 350 Oak Brook,IL 60523 I USA T : 630.571.1118 1 F : 630.571.0518 whitney-architects.com IL. CORPORATE LIC. 1 84-001 580 ESD 4 POLE S/N TRANSFER SWITCH Environmental Systems Design,Inc. 175 West Jackson Blvd.Suite 1400 o T. 0� o GENERATOR HOUSING 312 Chicago, 1200 rax 31s23721222 wwv.esdgiobal.com 0 w DPR License No.184-000892 IL STANDBY c' GENERATOR i GROUND PER CNEC 250.30 o • O I o J a 0 AUTOMATIC TRANSFER SWITCH SCHEDULE o I z NORM-EM GEN START TRANSFER EM-NORM GEN SHUTDOWN LOAD o • a — o DESIGNATION AMP POLES VOLTAGE DELAY (SEC) (YES/NO) TYPE DELAY (SEC) (YES/NO) DESCRIPTION AIC REMARKS I – ENGINEER 0 — ATS 1 200 4 480/277 10 YES AUTO 10 NO PNL H1 42,000 SEE NOTE 1 & 2 I ATS 2 100 4 480/277 20 YES AUTO 20 NO PNL H2 42,000 SEE NOTE 1 & 2 I ATS 3 100 4 480/277 30 YES AUTO .30 NO PNL H3 42,000 SEE NOTE 1 & 2 -- - N • 01 — — GROUND BUS I • Note 1: ATS until shall be programmed for walk-in current rate settings. In addition, provide current limit while on engine mode to 5%. J WI I Note 2: The ATS unit shall be a Bypass Isolation type, Open Transition, contactor based, NEMA-1 enclosure, UL 1008 Listed, • G111 CSA C22.2 Na. 17$ certified, 60Hz. Provide full front access with top & bottom entry and top exit feeder access. 7 -Provide all time NO and NC contacts (including aux contacts) as required for all control sequencing and monitoring, flt LiiZ includingannunciation to the existingFACP as required bythe Tigard Oregon AuthorityHavingJurisdiction & State of Oregon. GROUND BONDED q g g g TO ENCLOSURE C N — Provide all time delay settings as required by the schedule above and coordinate with the generator performance. All bus TO LOADS shall be copper construction. Draw—out type units. O Manufacturers shall be Cater filler, Cutler Hammer, ASCO, Onan, Russel—Electric or roved e uol to work in conjunction with GENERATOR GROUNDING DETAIL p pp qC3 n .. 2 NOT TO SCALI final selected generator manufacturer. 7 Coordinate all conduit & feeder routing in field prior to ATS and electrical closet layout and installation. = LCy 1__L 0 11 SETSOF FOR PASSTHRU SLEEVES 2 3 C. 0 4#10 & 1#10 GRD. 3/4"C. GENERATOR SERVICE FOR Immm. Cr) I— DISCONNECT SWITCH BOARD PORTABLE UNIT RATED 100%. LOAD im.:L 147)300KW/375KVA DIESEL GENERATOR, 480/277V, TO PANEL H3 FROM I BANK PHASE 4 WIRE, 60HZ, 1800RPM c) GENERATOR ACCESSORIES FLEXIBLE WEATHER PROOF 0 r PANEL. PANEL H3, CCT. 8,10,12 ATS WIRING & MONITORING SEAL-TIGHT GROUNDED 11111 300KW/375KVA STANDBY OUTDOOR CO RACEWAY . CABLES BY E.C. COORDINATEMAX MUM 6 FEET _ I 480/277V DIESEL GENERATOR IN LEVEL 2 SOUND & EXACT QUANTITY AND SIZES 30A.F. 3_/ WEATHER ENCLOSURE. REFER TO 4#10 & WITH MANUFACTURER. POLE GENERATOR BOOK SPECIFICATIONS FOR 1 10GRD. ADDITIONAL DETAILS 3/4"C. • I DISC. SW. r oc c? < I- -I 4#10 & 11/10 GRD. .3/4" SEAL-TIGHT HWG CONDUIT. I N-1 I 0 0 l I • 0 BUILDING EXTERIOR 2 SETS OF 4#4/0 & DWG E0.04 ] I I "C. FOR REMOTE J L J I GENSET LOAD CENTER FOR AUX. BUILT-IN SYSTEMS _ 1#3 GRD., 2-1/2" . [2MONITORING & ATS EACH WIRING ' \ if _ 2"C. FOR L.V. / mmyygrologioWPWP _ COMPLY WITH 2014 OREGON ELECTRICAL SPECIALTY CODE J NEC 2014, 250.50 & 250.94. CONNECTED TO COPPER MONITORING FLEXIBLE SEAL—TIGHT RACEWAY ' GROUND RODS PER CODE. PROVIDE UL LISTED RODS FOR Am / DIRECT BURIAL RESISTANCE TO GROUND SHALL BE 25 ISSUED FOR CONSTRUCTION 09.13.17 / DOUBLE WALL BASE TANK FUEL OHMS OR LESS. 1 ISSUED FOR BiDrP1Mlr 05. 9.17 \- 1 X C. TO MAIN MONITOR — $„ 700 GALLON SYSTEM (SEE CONTROL DOCUMENT FOR WP EXPANSION FITTINGS -_ MIN. .1,- REV. DESCRIPTION DATE ii ! I _ LOCATION) _ _. _ ISSUES I \ PHASE: EXISTING GRADE 1 CONSTRUCTION ' J2 STEEL BASE SUPPORTS AS / DOCUMENTS PER STRUCTURAL DESIGN & GENERATOR SET PHASE SPECIFICATIONS WITH ANY / ELECTRICAL 134 / REQUIRED SEISMIC ANCHORING & BRACING SHEET DESCRIPTION: GROUND BASE TANK PER 2014 OESC, GENERATOR 2014 NEC 2014, 250 & PER MFG. WIRING DIAGRAMS. RISER DIAGRAM CONCRETE FOUNDATION SLAB & FOOTINGS AS PER STRUCTURAL ENGINEER DESIGN FOR 700 & DETAILS GALLON WET TANK & GENERATOR WEIGHTS. APPROXIMATELY 17,000LBS, 174"L X 105"W FLOOR NO.: 1ST NEW 300KW/375KVA OUTDOOR DIESEL GENERATOR DIAGRAM NOTE: ALL WORK, EQUIPMENT, RACEWAYS, AND CABLING SHOWN ON THIS DOCUMENT ARE NEW UNLESS NOTED OTHERWISE. FLOOR I NOT TO SCALE Scale: Job Number: NONE 52322 North: Drown: F Chkd: E0 . 11 JS Imo mu,,9lzc n T:\option Care — Portland OR\Option Care — Portland OR\DWGS\CAD\Elec\eg_01 .dwg 9/1.5/2017 12:09 PM kmchone Copyright © 2017 by Environmental Systems Design. Inc, MDF ROOM NOTES: 4. PROVIDE 2#12 & 1 #12G., 3/4"C. FROM POWER KEYED NOTES: PANEL (20A- 1P CIRCUIT BREAKER) AND CIRCUIT [\ EC SHALL RECIRCUIT AND RE-FEED WORKSTATIONS (-- ALL POWER POLES SHALL BE WIREMOLD POWER POLE \/Jj-i I T N E Y 1 . EACH EXISTING RACK SHALL RECIEVE (1 ) L5-20R AS NOTED FOR SECURITY PANEL POWER FEED o EC SHALL PROVIDE DIMENSIONED PROPOSED LAYOUT OF THROUGH EXISTING POWER POLES TO PROVIDE DEISGN ` ' TYPE 30TC-4V OR APPROVED EQUAL. PROVIDE ADD-ON RECEPTACLE MOUNTED TO LADDER RACK. (120V, 1PH). ELECTRICAL CLOSET FOR FINAL REVIEW TO ENGINEER INTENT. COORDINATE WITH FURNITURE MANUFACTURER 30TP-B & 30TC-CVR DEVICES AND COVERS AS ARCHITECTS, INC. PROVIDE 2#12 & 1 #12GRD., 3/4"C. FOR 5. REFER TO TECHNOLOGY DRAWINGS FOR GROUND PRIOR TO PANEL AND EQUIPMENT INSTALLATION. FOR WIRING REQUIREMENTS PRIOR TO INSTALLATION. REQUIRED TO PROVIDE POWER AND COMMUNICATIONS 700 Commerce Drive I Suite 350 L5-20R RECEPTACLE. COORDINATE FINAL BAR AND GROUND CONNECTION DETAILS. DEVICE REQUIREMENTS AS SHOWN ON PLANS. PROVIDE 1 Oak Brook,IL 60523 I USA LOCATION WITH COMMUNICATIONS CONTRACTOR NEW CONCRETE BOLLARDS AND - 6'-9" - FIELD WIRING AS REQUIRED TO ACHIEVE CIRCUITING \ T : 630.571.1118 I F : 630.571.0518 FOR FINAL LOCATIONS. SCREENING AS REQUIRED BY CONCRETE PAD - EXTENDED 12" INTENT SHOWN ON PLANS. COORDINATE ALL FINAL J whitney-architects.com PROVIDE STATIC DISAPPATIVE TILE AND LANDLORD AND AHJ. TYPICAL r- 2. 5' BEYOND GENSET FOOTPRINT IN ALL POWER POLE LOCATIONS WITH ALL OTHER TRADES AND <\ GROUNDING CONNECTIONS. DIRECTIONS EQUIPMENT, FURNITURE PROVIDER, AND ARCHITECT IL. CORPORATE LIC. 184-001 580 3. REFER TO COMMUNICATIONS DRAWINGS FOR ALL a PRIOR TO FINAL INSTALLATION. CONDUIT REQUIREMENTS. E.C. SHALL PROVIDE I IL NOTE #12 & #14 AND INSTALL WITH PULLSTRINGS. „ } 5 FEET CLEARANCE AROUND GENSET (4\ PROVIDE WIREMOLD V2400BD DIVIDED RACEWAY DEVICE. PROVIDE ALL REQUIRED PLATES AND ACCESSORIES. ESD DISCONNECT H 1 IN ALL DIRECTIONS AND FROM COORDINATE LOCATION AND COLOR WITH ARCHITECT. o 0 0 \ EXISTING PNL L:? 0 ' BUILDING 0 _ Q_ Environmental sy5sem5 Design•Inc. ci,, TO BE ,/ 1 4'-' L" �! 175 West Jackson Blvd.Suite 1400 Chicago,Illinois 60604 METER DEMOLISHED. 312 372 1200 fax 312 37Z 1222 ATS- 1 www.esdglobal.com PNL H2 REFER TO RISER I ATS-2 I I DPRLicense No. 184.000592IL /7 EXISTING 15KV TRANSFORMER FEEDING PNL L2 TO E DEMOLISHED. I DIAGRAM FOR . • ' ii\ DETAILS. Z� ATS-3 1 REFER TO RISER DIAGRAM FOR DETAILS. o- I I____ i PNL H3 NOTE #13 l A �.'5._)7 ,,.r_ E c� B26 B6 826 - _ -� ,bE B20 �/ f . . -.- I ° NEW 150A D.S. LL 11111 46 'LLE ' /7// ,% :' /'--.7---:-.7.7_-_.::-__. //// -- DISCONNECT H3 sm. 4 TORAGE a a VESTIBULE STORAGE \ 1 1 4 PANL GEN-DP ENGINEERING B22 NEW 45KVA1T 6.tt 1 33 6 B2.4 '''% i/'- ENGINEER ---- --- �\ ��vv E / 1 1 2 VESTIBULE '�. B22 \ / °W�s XFMR 624E B24 E ��' B22 ttt e 0 I / / / F11 I 622 ii 3 ®{ I di!,• I . F{I,la r ,i,ii, l 623 l6 P 17 CC1Q �QQ ❑� �Q // //// // / / ',SHELF 9 ,' L B35 4 LB,3 B37 4 Il B374 L J PNL P * * * �, / ' ' I -833-- U6 P27U6 P29 U6 P27 P31 P33 75KVA ' '. ► - :'ME: ' • .: /EXISTING INL L 1 S 1 TO BE DEMOLISHED. .' /' ' f SHELF SHELF ,o,,. 8 <,, I e PNL H1 TO ' i B27 REFER. TO RISER DIAGRAM FOR DETAILS. - / PAE"RACK • IF PACY B18 PNL L1 I s P111 I / PNL L11B co co col �� m m��� P9 .-11 ; �,� PNL L1 A `'- p3 l PHARMACY PRE r I / / / / / W l� P 1 P35 P37LL �� 12 S . HEI J II 0 r' 7 f ■i w `� / WAREHOUSE _• 829 •fir :•0nr►r ( T]1 ` � SHELF 1 % // /� - Ljj iy I1iv:3 P35 c P7 P 13 / 1 1 1 ��� B2 t ; . JANITOR SEE �/, JI B z 4 0 w P11 .__ , // // / / CL lin / (/) 4. ,. 11 7 ENI INtE' .. 20 P47 - - G D • I / LI_ L-; 1 "_' w 1 E •2 y ' T , - - - �.�s" j . // CIRCUIT NUMBERS ARE" FOR �/� • ,• *1827 i B16 827 SE D , ,.,_.0 O U I I Ill P47 P47111 311 [111 SHE!' f DESIGN INTENT ONLY. REFER TO ,�' /, /, < -0411r> r:,,,/,///////./., 1 �3 -I tnY ' �1 ,.'` ROOM B25 2P2 _2 P2Q ^^; P11 -- 'ANGSTROM' DRAWINGS FOR �J i i I I _ I: T �, �...� 1 /ADDITIONAL DEfAjLS ,AN[�/A / CI NOTE#1 k - -' i - P24 P22 2 Pia P30 48 CHANGE I ' -. , E ► /// - ENGINEERING I i I� Q- �- 0] _ B25 ` 1 P18 �� ,7 ITHR _�4) C2 CONNECTION ROOT1N & I N / �fw w w u w �� .�a E r I �* L AN E,ROOM I 1 2 9 C23V / ' • L Ci U_ LLIT = _ _ z __ �� _- 5 -P$ REQU1R MOTS... / , z I 2 I„ z 8 � _ c21 N � E ' fll- u 827 0' 10 PS E B 1 2 a Ir 1 I CLEAN ROOM GFI LOCKER ROOM ASS " C27�sn ATF �� z o c CORRIDOR l 3ao. .:+ ' / / CD Cl J ✓JI _ CP B13 . _ �f �20 1 22 1 26 1 30 1 l's i• :ORATIENI „, i Er P 0 P1fi " 021 t 1 32 / /I /', ` _ ....._.CL +04� MEN'S (INIEN"' ►� P32 I SHELF SHELF SHELF SHELF 1 WELLNESS B 1 5 RESTROOM � TROD F2 I I P24 TR 1 r CORRIDOR 1 ! " ROOM 44-AFF=- 1 1 5 ?II CFI � El �r E STORAG PNL U1 �j `� 1111 B2 a.. LO lllo I B1 1g 116 ; 12 20 VA UPS �- I. .(•:- ,'::. � �0 C25 1 0 I I /t/1/ 109___._ ____ B 17 ® 1312 = i - � 35 ���s'' C21 E = /� ' A .. 1/ 1 . � E - P12 P28j Ili v P4 1 ; E . / . _ � �' ,/ ' 7!--.7-.74-7 ______. .____ 0 qir"""" 1. '`/►t'y., l _ a < i 4 1I CD :1E 4=C '''' 01. 18 - E#4 ci'll 'l o6mROOM NOT 2 PPL_- 4 P' PPO Eft ///, �8 Willi E E E I /E E E E E C22 C24II7 - C141 . C16 IC6 C8 E /� / / /f;R*OM ') B1a C B10 at 4 1 1 '' C6 "7 C8 . .... / / /.034 C C. I , * C22* C2 * ' FC •. C 6*B 3u27 u2s 'u1 u21 u7 ' ug a; .. ,1 / f'/ ; i �,� /C34 1U3* // / i ,C ' ' ,f1, U35* Lf j I' 1A ` CONFERENCE - 1� TI I / , ` /I C36 1 • I 0 ' 24 1 C , '1 ' / / / / i' I: /C2 �• U. * U27* U29* I U19* I U21 * U7* '� U9* / / / C36 C2 11 ' t Ii • fr. I' 20 / , �/ ki To I U._3_.113I, , � c� C26 ' C28 C18 1 --C20 c10 , • C12 1/ f/ /; / IPP ' C• C26 C28 018 C20 C10 C12 I / /1 U,31',, U23*- - U25* U 15* ' - U17* U U 1 * 7. 3 ISSUED FOR CONSTRUCTION 09,1317 t , , , REs�aoM B4 i:-) B4 Ofq, / , , /' / A 18 E �' '1� 0 E 111 86 L E E ,, �;. , I / A/ , /' 2 ISSUED FOR PERMIT REVISIONS 09.1317 E P TP V 11� .� C32 , C26 028 C18 I ; C-20 0 �1/ Y� / AIF ._,,, ti FI 3 A17 C 2C26 C2& C18 ! �C20 L,�CyO //I, ,,'r i /E _ / ;' 1 155UED FOR BIDIPERMiT 05.1917 .; 1* U23* j63� e A27 : (R- t- , EU6. _ _� U25�4 15 r; 7� 11 ,E ,-� E `,'� / i i I U U1 U v `QI `W •i.72"hFF '� .... • - l A34E I / ,�' / B1 r) A16'�'44.AF� I WAITING .. A J __ I t. E AOT- 1= �� /�` , ,' REV. DESCRIPTION DATE ,7 BREAK ROOM GFI 1 02 ., E C® ii 1 07 A3a ,E AFF EA17 / l f 1 I , //; //. // /,, /,://`�` / ISSUES .. CONFERENCE CONFERENCE CON' RENCE C6 ERENCE VISITOR I / / / ' / PHASE: A20 c LJ L- ,� F� RECEPTIO '10M ROOM .._- , ,�, , Tt. ROI; •ODM OFFICE 1 1� /f / /• j� / ri __ _r_i1j \\ �` yJ■ 1 40 7 39 . \ ' 137 136 e 1 35 Al PRIVATE OFFICE E DJ u I / I 1 //' / A32 �9 - e , ; a E 1134 �) I CONSTRUCTION 4rB 1 I I -� �A23 A23 E cel i 3,A3/ �.� ` •ITOR U 1* E ----� �72•AF�i ' immi0l AO ' DOCUMENTS V -1 840s.CP"TREAT • MENT �` E 'TREATMENJ�A] rct:a A' _"�+ �, .E E J , ,'..41 , FICE QA1 _ '�t1 - tFE = E�j 1 I I ti /' ., �. A ROOM e\/LIE _ .. ,_,. _._, V E s -= E / A7 QE ��� _ :7:113 r11-'1$]OM E A25 1 O3 ' ; e'.'' F -• k Ii�F4'A3E `.E ler -i - . •/E . E' �1 ` �.B1EPHASE s. 1 04 E X44 AFF 344•AFF - �° 3 B42 ' SZ E,:n� FIE A25 : - �1 - --- _ t >~ Al Al Al4P. , Q out 1 c � SHEET DESCRIPTION: POWER NOT3. LOCATIONS OF FLOOR BOXES, POWER FEEDS DOWN CONFIGURATION WITH ARCHITECT AND FURNITURE 9. INSTALL BACK BOXES AND EMPTY CONDUIT RACEWAY WALLS & COLUMNS ARE SHOWN FOR DESIGN INTENT MANUFACTURER. PROVIDE MULTI-POLE BREAKERS AS SYSTEM FOR ALL COMMUNICATION DEVICES. 12. REFER TO E0.11 & GENERATOR SPECS FOR ELECTRICAL 1 . ALL CIRCUITS FOLLOW CIRCUITING DESIGNATION "XXYY" AND REFERENCE ONLY. DO NOT SCALE LOCATIONS REQUIRED BY CODE. ALL UPS BACKED UP CIRCUITS COMMUNICATIONS CABLING BY OTHERS. PROVIDE GYPSUM GENERATOR DETAILS. WHERE XX DENOTES PANEL AND YY DENOTES CIRCUIT OFF DRAWINGS. COORDINATE EXACT LOCATIONS AND SHALL BE ORANGE IN COLOR. BOARD RING AND PULL STRING IN EACH EMPTY CONDUIT. CIRCUIT ASSIGNMENT LEGEND POWER NUMBER. CIRCUITS NOTED AS "XXYY*" SHALL BE REQUIREMENTS OF ALL FLOOR BOXES AND POWER OR COORDINATE EXACT LOCATIONS WITH COMMUNICATIONS 13. PROPOSED NEW UNDERGROUND GENERATOR SERVICE COMPUTER CIRCUITS BACKED UP BY UPS, RECEPTACLE TELE/DATA FEEDS WITH OWNER, FURNITURE 7. COORDINATE ALL FLOOR BOXES, CONDUIT STUB-UPS CONTRACTOR, REFER TO COMMUNICATIONS DRAWINGS FOR FEEDERS CONDUIT. CONTRACTOR SHALL CONFIRM AND CIRCUIT ASSIGNMENT LEGEND: "XYl'" PLAN CABLING REQUIREMENTS ANDATACONDUIT/ COLOR SHALL BE ORANGE IN COLOR OR AS SELECTED A CONTRACTOR, ARCHITECT AND GENERAL CONTRACTOR AND TRENCHING LOCATIONS WITH ARCHITECT AND ALL TELEPHONE/ PROVIDE ALL PROPER ROUTING AND COORDINATE WITH " - • , - - I , BEFORE PROCEEDING WITH WORK. UNDERGROUND UTILITIES. ADDITIONAL INFORMATION. ALL LOCAL UTILITIES, STRUCTURAL, AND LANDLORD. -"X" INDICATES PANEL ASSIGNMENT FLOOR NO.: PANEL NOTATIONS. CIRCUITING SHOWN FOR DESIGN 10. INSTALL BACK BOXES AND EMPTY CONDUIT RACEWAY PROVIDE ALL NECESSARY TRENCHING. -"A" - EXISTING 208/120V PANEL "L1 " INTENT ONLY. 'E' DENOTES DEVICE IS EXISTING TO 4. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT 8. PROVIDE EMPTY CONDUIT RACEWAY SYSTEM AND BACK SYSTEM FOR ALL AUDIO/VISUAL DEVICES. AUDIO/VISUAL -"B" - NEW 208/120v PANEL "L1A" 1ST REMAIN. RECIRCUIT AS REQUIRED TO MATCH DESIGN QUANTITIES, LOCATIONS AND MOUNTING HEIGHTS OF BOXES AS REQUIRED FOR A COMPLETE SECURITY CABLING BY OTHERS. PROVIDE GYPSUM BOARD RING AND 14. NEW OUTDOOR DIESEL GENERATOR WITH LEVEL 2 -"C" - NEW 208/120V PANEL "L1B" INTENT. ALL POWER AND TELE/DATA OUTLETS. INSTALLATION. SECURITY CABLING BY OTHERS. PULL STRING IN EACH EMPTY CONDUIT. COORDINATE EXACT WEATHER & SOUND ATTENUATED ENCLOSURE -"U" - NEW 208/120V PANEL "UPS- 1 " FLOOR COORDINATE WITH SECURITY CONTRACTOR FOR EXACT LOCATIONS WITH AUDIO/VISUAL CONTRACTOR. REFER TO APPROXIMATELY 81 W X 174 L X 1 12 H, 17,000 -"P" - NEW 208/120V PANEL "PH" 2. FOR ALL ELECTRICAL DEMOLITION, CUTTING CABLE AND 5. MAINTAIN CODE REQUIRED 3' WORKING CLEARANCE LOCATION OF DEVICES, EQUIPMENT, AND FINAL AUDIO/VISUAL DRAWINGS FOR ALL AUDIO/VISUAL POUNDS WET WEIGHT. PROVIDE NEW CONCRETE SLAB CONDUIT BACK TO THE WALL OF THE ELECTRICAL FOR ALL NEWLY LOCATED PANELBOARDS AND TERMINATION POINT. REFER TO SECURITY DRAWINGSAND FOOTING, EXACT SIZE TO BE DETERMINED BY CONDUIT/CABLING REQUIREMENTS AND ADDITIONAL -"YY" INDICATES CIRCUIT ASSIGNMENT Scale: Job Number: ROOMS IS NOT ACCEPTABLE. THE ELECTRICAL EQUIPMENT. FOR ALL SECURITY/CABLING REQUIREMENTS AND INFORMATION. FINAL SELECTED GENSET. COORDINATE EXACT GENSET 1/ADDITIONAL INFORMATION. PROVIDE FIRE ALARM TIE-IN LOCATION WITH ALL UTILITIES & LANDLORD AND LOCAL • 8"=' I 52322 DEMOLITION SCOPE OF WORK SHALL INCLUDE THE ' REMOVAL OF ALL ELECTRICAL WIRING BACK TO THE 6. OPEN OFFICE FURNITURE SYSTEMS CIRCUITED BASED AND CONTACTS FOR ANY ELECTRIC STRIKES TO FIRE 11 . COORDINATE GENERATOR ANNUNCIATOR PANEL AHJ & STATE FIRE MARSHALL FOR ANY REQUIRED North: Drawn: OVER-CURRENT PROTECTION DEVICE AND THE ON A (2+2) 8-WIRE (2H+ 1 N+ 1 G, 2H+ 1 N+ 1 G) ALARM SYSTEM. LOCATION WITH SECURITY CONTRACTOR EQUIPMENT SCREENING AND/OR LANDSCAPING. PROVIDE AND JS REMOVAL OF ALL CONDUIT BACK TO THE PANEL CONFIGURATION. COORDINATE FINAL WIRING LOCATION. INSTALL CUSTOM METAL FRAME STEPS TO GENERATOR O 4, 8, 16' Chk d: E 3 . O BOARD OR SWITCHBOARD ENCLOSURE. FOR ACCESS TO OVERRIDE DISCONNECT BREAKER. JS 6.611 15. ALL WIRING SHALL BE RUN IN EMT/IMC CONDUIT PER %o�,.. 9 (2017 ELECTRICAL SPECIFICATIONS. C.,eName o,thvg I:\Option Care - Portland OR\Option Core - Portland OR\DWG • I lec ep_i .•wg • 72017 12:09 PM kmchone Copyright ® 2017 by Environmental Systems Design. Inc. WHITNEY ARCHITECTS. INC. 700 Commerce Drive I Suite 350 Oak Brook,IL 60523 I USA T : 630.571.1118 I F : 630.571.0518 whitney-architects.com IL. CORPORATE LIC. 184-001580 ESD 0 0 0 4 410 6trA 8 9 Environmer+laV Systems Design,Inc. 175 West Jackson Blvd.Suite 1400 Chicago,Illinois 60604 312 372 1.200 fax 312 372 1222 www.esdglobal.com I I I License No. 184-000592IL I I I I I I I I 1 �_ A 1 o I I f M10 _ , t� STORAGE r . 3 OSS ne Ie I OS e ® ELEC ® OS g VES IBULE OS g 674.4/-IS _133 IFr / I/'� 1 z VESTI E EM6a r+-9 10---►1 I 410 1 23 M10 //// 1 J S L „rcTiDi„r fiR f Dill 1 4 ♦ 6h / / i' 5WHAI,E C '- ® D6e EM6a D6e D6e1E-We D6e lt3'- D6f EM6 D6 D6 EM6 h //////:////// / 1 g {� g itENGINEER 1 1 3 ®10 M10 l '\ / 11 ° '. a I 1 i/,:. /.:,- Drli aC 3 3¢ FREEZER:.s ¢ ¢ i Ri EZEP I R -- i�M6 STAT DfVr-L] P&P # TAT O I STAT ON P&ION! LaJI - I - IF �S P41tri '♦ //i/ / 5H� Lu4 WAREHOU u u u ' OLER 00,- 3 M■ , / / /' ' / S P43 I a ��r vv ii,/ ® SHELF a,b 3Wb o W o'b EM10 1 1 �I TA; >� 10 I �3 P41 � �misura• '41 11 I21 060 EM6aD6a D6aI7//4f ab an f SOOLER ODLER ' - -i CY P - ; LLJ D rii + glia ,11 -._.IID6o _iCi ITORs :•43 P43 P43 P41 ( P41 P41 -P41 a / / CL �� i I f � l " I 117 • 1 !il � © __ �P41 DJ se �/ / I/ / i' /' / I w ---t D A1 . NOTE 11 .... �, CIRCOIT/'NUMBERS ARE FOR D6a �M v, 'D6a I 1 inn _(. .. "T :-i..r. : HVAC POWER NOTES: 8. CONTRACTOR TO COORDINATE WITH MECHANICAL WHITNEY 4. ALL WIRING SHALL BE RUN IN EMT/IMC CONDUIT PER 7. PROVIDE SMOKE DETECTOR IN RETURN AIR DUCTWORK. CONTRACTOR TO PROVIDE DUCT SMOKE DETECTORS ON 10. 'EX' DENOTES EXISTING TO REMAIN, NO NEW WORK ARCHITECTS, INC. 1 . REFER TO DRAWING E3.01 FOR ALL PANEL LOCATIONS. ELECTRICAL SPECIFICATIONS. DETECTOR SHALL BE WIRED TO THE SPRINKLER/DUCT ANY EXISTING ROOF TOP UNITS WHICH REQUIRE SMOKE REQUIRED. 'R' DENOTES EXISTING TO BE RELOCATED, 700 Commerce Drive I Suite350 DETECTOR MONITORING PANEL AND PROGRAMMED TO DETECTION PER CODE AND DO NOT HAVE EXISTING EXTEND WIRING AND CONDUIT AS REQUIRED. Oak Brook,1L 60523 I USA 2. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR 5. PROVIDE 120V, 20A CIRCUIT FOR VAV TRANSFORMER. SHUTDOWN THE ASSOCIATED ROOF TOP UNIT AND DUCT SMOKE DETECTORS. T : 630.571.1118 I F : 630.571.0518 EXACT EQUIPMENT LOCATIONS. COORDINATE WITH MECHANICAL CONTRACTOR. PANEL GENERATE A VISIBLE AND AUDIBLE SIGNAL UPON whitney-architects.com 'L1 B', CCT 17. DETECTION OF SMOKE. A:REMOTE KEY TEST SWITCH 9. PROVIDE SELECTIVE NOTIFICATION THROUGHOUT AREA 3. CONDENSATE PUMP SHALL RECEIVE DEDICATED 20 AMP SHALL BE PROVIDED FOR THE SMOKE DETECTOR. OF WORK TO ACTIVATE ON WATERFLOW PER IL. CORPORATE LIC. 184-001580 CIRCUIT, 2#12 & 1#12G. 3/4"C. FED BY PANEL 11131 6. PROVIDE 120V, 20A CIRCUIT FOR VAV TRANSFORMER. COORDINATE WITH ELECTRICAL, FIRE PROTECTION, AND REQUIREMENT OF THE AUTHORITY HAVING JURISDICTION. CCT. 15. COORDINATE WITH MECHANICAL CONTRACTOR. PANEL MECHANICAL CONTRACTORS AS NECESSARY FOR THIS EXISTING NOTIFICATION APPLIANCES USED FOR THIS 1113', CCT 19. WORK. PURPOSE SHALL BE DEMOLISHED AND REPLACED WITH NEW. ESQ 0 0 0 (430 ,6.2 0 8 9 Environmental Systems Design,Inc. 175 West Jackson Blvd.Suite 1400 Chicago,Illinois 60804 312 372 1200 fax 312 372 1222 www.esdglobal-com i I I DPR License No.184-000892 IL ® ,-,.-=-1.-:11.11 -:.. ------ ,AI*.tt A,ro odza,...,...M.• .-4.-r...i..,,e0i....,,,•. •. 1 I I I 1 . I I ELEC / / /r / - I i / // / •` F I VEST 1 2 3 I STORAGE f IBULE � UH VESTIBULE //// l / STORAGE I T--: - 1 1 14 1 3 3 / / ` / ------__�_-_ _ __ 1 1 2 - VESTIBULE I I R I 1.02 4 I \ I I' / //i/� / / I ENGINEER -M - __ ii _ � li!'<l - ...-:..:s,. :. .... / / ; /1 . CUH :I' I ' i ' `1 .01 [�j- - LIJT I I I I � I, � _ __�. __ I �. �_. I / / [ Lc.. ., :. ._ _ , ///;)1/// ///// '1. , / ! .���1' 1� _---jPHARMACY PREM .er // ' / / /• 125 M1 ' / / 1 / y , ,. ,... LLI I / f lLIJ WAREHOUSE 1 1 8 .■l�Lri �►w I I /' 111 I JANITORS I I , '� '/ ' / iv 11111 H / Ct LLI I [ 10 % IS I 1 y �� 1 . - REFER TO ANGSTROM DRAWINGS /// // / / / 4 / / Q I � z ��-- 0FOR DDITIONAL DETAILS- AND " / / CD ® Ili r--� l ALL ONNECTION ROUTING & I i / (..) CI ... all NUL_J 1 -� I • CHANGE I WIR1N REQUIREMENTS: �///// ■� 1 1 9 EX Arm _ 1 2 , I / A.r, 1 ■� 1 � ., 2$ 1 1 � Z N _ H I / / LL LOCKER ROOM PASS THRU { 0o o4 UPS CLEAftrROOM ' I. / ./ ; I0 ' to< 0 0 120 �-- CORRIDOR 01 I. 20 1 22 1-26_. . J 1 30 1 31 I COLLABORATION AREA MEN' tMEN'S �W 1 3 2 / WELLNESS RESTRO, I RESTROOM _ APR CORRIDOR ROOM 1 1 5 ' STORAGE ��/ k _ 1--, / / / %/� f 1 1 0 I 1 09 1 1 6 1 21 ti02 i 1 27 I " /;' �. ® ICL LO e i I ! 1 II I 1.02 _ { d7 B -�.���-��� -- :l .mss is i,i !,i i i, __ _� - -� _��-��`��- - - - ___-_ 0 I1//. --�--� Ir - ,��,ii,i,i:i:l�l�i:l:l.l�l�!_i:i� i!-:!:l�l�.�:! ^, �1:. / . , ' OPEN OFFICE ------ V 7/1 I00 //7//1/1/ // I1III I //I / ` /` / / CONFERENCE SEE NOTE#7 // / ' / / / ROOM SEE NOTE#7 SEE NOTE#7 /// / / � �; / , CONFERENCE • ROOM � A / ;I /y/ � i , / /// . : i 108 ' / f'//// , A I I I I I , / , , I I I 3 ISSUED FOR CONSTRUCTION 09.13.17 SEE NOTE 6 r ///// ////.../,TRESTRDOM _ '' /://./7///./.:/// ///1/1/./ 2 ISSUED FOR PERMIT REVISIONS 09.13.17 I 105 I I `1 i I I I / / 1 ISSUED FOR BIDIPERMIT 05.19.17 SENOTE#5 - / / / (4$ �6_ -\ WAITING I AREA I�� REV. DESCRIPTION DATE BREAK ROOM ® 1 02 i , , //,///1 ISSUES 107 I/ T ,,.,,: ACONFERENC. ... I / / / //f/ .. .; _ �I�I COC0' ENCS INFERENCE VISITOR / i/ �' PHASE: RECEPTIO II - OFFICE T�yraF. irlriw � II / /�/ ' 101I �Q� 1 3 \ / ` Wm .TI1, 6 '.T `• 35 .PRIVAIIE OFFICE I I / ,/• -41 - ,. ► CONSTRUCTION 1 1 / i ,� o O © O I O 1R:lTOR o O ' O O O O �.04 �! , I TREATMENT 1 .03 I i FICE I I / ' ' / / / . I DOCUMENTS TREATMENT ROOM 1 3 8 / 1 ROOM I \ :: _ _____. ti ,,.......�: � ,` �- ._- �� , 03 I I I / / { PHASE 1 04 II � // I C I I J SHEET DESCRIPTION: HVAC POWER + EQUIPMENT SCHEDULE EQUIPMENT SCHEDULE NOTES: PLAN EQUIP ID DESCRIPTION VOLTAGE - LOADS PANEL SERVICE CCT NO. OCP WIRING SIZE CONDUIT SIZE DISC SW STARTER REMARKS 1 . COORDINATE EXACT LOCATION AND FINAL ELECTRICAL " PHASE KW HP AMPS FROMi. FUSE/CBI POLE SIZE POLES SIZE TYPE REQUIREMENTS WITH MECHANICAL CONTRACTOR. FLOOR NO.: _ r .- 2. COORDINATE EXACT LOCATION AND FINAL ELECTRICAL CUH-1.01 CABINET UNIT HEATER 277-1 6 - 21.7 H3 17 - 30A 1 2#10, 1#10GRD. 3/4" 30A 1 - - NOTE#1 REQUIREMENTS WITH PLUMBING CONTRACTOR. 1ST CUH-1.02 CABINET UNIT HEATER 277-1 6 - 21.7 H3 14 - 30A 1 2#10, 1#10GRD. 3/4" 30A 1 - - NOTE#1 FLOOR CUH-1.03 CABINET UNIT HEATER 277-1 6 - 21.7 H3 16 - 30A 1 2#10, 1#10GRD. 3/4" 30A 1 - - NOTE#1 CUH-1.04 CABINET UNIT HEATER 277-1 6 - 21.7 H3 18 - 30A 1 2#10, 1 #10GRD, 3/4" 30A 1 - - NOTE#1 UH-1 .02 UNIT HEATER 120-1 - - 3.3 L1 22 - 15A 1 412, 1 #12GRD. 3/4" 20A 1 - - NOTE#1 Scale: Job Number: RP-1 RECIRCULATION PUMP 120-1 0.09 - 0.8 L 1A 28 - 15A 1 2#12, 1#12GRD. 3/4" 20A 1 - - NOTE#2 v8°=11-o" 52322 AC-1 .02 AC UNIT 208-1 - 1.4 L1B 3,5 15A 2 2#12, 1 #12GRD. 3/4" 20A 2 - - NOTE#1 North: Drown: JS 0 4' 8' 16 440Chk'd E5 . O1 JS ala,n.,.VV., rn.Na,,.M u,.a..g I:\Option Care - Portland OR\Option Core - Portland 01-\DWCS\CAD\Elec\eh_01.dwg 9/13/2017 12:10 PM kmchone copyright © 2017 by Envfronmentol Systems Design. Inc. HVAC POWER NOTES: 4. PROVIDE ROOFTOP WEATHERPROOF, C,F1. 6. REFER TO E5.01 FOR DUCT SMOKE 7. 'EX' DENOTES EXISTING TO REMAIN, NO NEW RECEPTACLES WITH UNISTRUT MOUNTING. DETECTOR LOCATIONS. PROVIDE SMOKE WORK REQUIRED. 'R' DENOTES EXISTING TO \A/IHI I T N EY 1 . REFER TO DRAWING E3.01 FOR ALL PANEL COORDINATE EXACT LOCATION OF DETECTOR IN RETURN AIR DUCTWORK. BE RELOCATED, EXTEND WIRING AND LOCATIONS. RECEPTACLE WITH EQUIPMENT DETECTOR SHALL BE WIRED TO THE CONDUIT AS REQUIRED. ARCHITECTS, INC. MANUFACTURER TO PROVIDE ALL CODE AND SPRINKLER/DUCT DETECTOR MONITORING 700 Commerce Drive I Suite 350 2. REFER TO MECHANICAL AND PLUMBING MANUFACTURER REQUIRED CLEARANCES. PANEL AND PROGRAMMED TO SHUTDOWN 8. E.C. SHALL TRACE OUT FEEDERS FOR EACH Oak Brook,IL 60523 I USA DRAWINGS FOR EXACT EQUIPMENT CIRCUIT TO PANEL 'L1 B'. THE ASSOCIATED ROOF TOP UNIT AND EXISTING TO BE REUSED ROOF TOP UNIT TO T : 630.571.1118 I F : 630.571.0518 LOCATIONS. GENERATE A VISIBLE AND AUDIBLE SIGNAL PANEL AND CIRCUITS BEING USED AND whltney-architects.com 5. ALL WIRING SHALL BE RUN IN EMT/IMC UPON DETECTION OF SMOKE. A REMOTE KEY PROVIDE TO ENGINEER FOR EVALUATION AT 3. PROVIDE WEATHERPROOF SEAL FOR ALL CONDUIT PER ELECTRICAL SPECIFICATIONS. TEST SWITCH SHALL BE PROVIDED FOR THE BEGINNING OF CONSTRUCTION. IL. CORPORATE LIC. 1 84-001580 ROOF TOP CONDUIT PENETRATIONS WITH A SMOKE DETECTOR. COORDINATE WITH CURB TO MAINTAIN ROOF SEAL WARRANTIES. ELECTRICAL, FIRE PROTECTION, AND MECHANICAL CONTRACTORS AS NECESSARY FOR THIS WORK. CiSCI--- 0 e 9 (- Environmental Systems Design.Inc. 4D �60---- 8 9 175 West Jackson Blvd.Suite 1400 Chicago,Illinois 60604 312 372 1200 fax 312 372 1222 www.esdglobal.com I I I I I DPR License No.184000892 IL I 1 I I I I I i I I I I I A — I I I I - : . 1 I I I A CIRCUIT TO PANEL 11B1 CCT.#1 1 S(E NOTE #4. I I I ENGINEER W ..T WP I r ® • tl' GFI WP 1 t '. ' I • r--7 II I 1 c21 I I 1 J � ARTU I WI I I I L__J I 1.10 i I LII EX - IZ1 I IA I I I I z L u r� I If- I 1 1 I I E © 1 Q L L__J I I I I 1 EXI I 0 L___I EX I I I I � I [] ._ I I I I zo I I i i I I I CIRCUIT TO PANEL 'L 1 B' CCT.#1 1 CIN (: O I I Q EX � I WP I SEE NOTE 4. 1 ~ EX �� I WP t_J I I I T I I 1 GFI Wp I I I I— An WP 1 .02 EF I � CIRCUIT TO PANEL 'L1 B' QCT.#1 GFI 1 1 .01;076: 1 jCL --- SEE NOTE #4. I _ I I I I � ------s--tel_---- _F_-_12,_ --- -------- -J _1---.--------------___.__i___- ____-. 0 N-- ICT I IC I ICT 1 l CO t I 1 I 1 I tl11 I 1 / I I I I L_ IJ II_' I / I L--J TEX L--L i I EX ' I EX ' I I / ; ., /I/ / / I I I I - /CIRCUIT TO PANEL L18 CCT.#1 I I /I , SEE NOTE #4. I I I /I WP I I I I f I GFI I I I II .. _ EX I I I I j I / I L J I I I / //l I 3 ISSUED FOR CONSTRUCTION 09.13,17 I-- I I I I I f --, I I I // ' 1 2 ISSUED FOR PERMIT REVISIONS 09.13.17 r 1I I II1 I /I 1 ISSUED FORBID/PERMIT 05.19.1�7 121 xII x - j / II I I REV. DESCRIPTION DATE rj JI EX ' ISSUES I / , I PHASE: I 1 I I -' CONSTRUCTION 1 / 1 I I I I I / / DOCUMENTS TS / , / PHASE, — r T SHEET DESCRIPTION: ROOFTOP EQUIPMENT SCHEDULE NOTES: HVAC POWER 1 . EQUIPMENT SHALL SERVE CLEAN ROOMS. COORDINATE CLEAN ROOM MANUFACTURER SPECS FOR FINAL PLAN EQUIPMENT SCHEDULE CONNECTIONS. V3-5 2. COORDINATE EXACT LOCATION AND FINAL ELECTRICAL I . i - - .� • p I E REQUIREMENTS WITH MECHANICAL CONTRACTOR. FLOOR NO.: E s ► ' ID DE ' 'IR. 1 ` r / i� '� ..A . CCT 0. NG E CO IT RE KS PHASE KW HP AMPS FROM SW. FUSE/CB POLE SIZE POLES SIZE TYPE RTU-1.09 NOT USED - - - - - - - - - - - - - ROOFTOP RTU-1.10 ROOFTOP UNIT 480-3 - - 16.8 I-11 26,28,30 - 20A 3 4#10, 1#1 OGRD. 3/4" 20A 3 - - NOTE#1 A EF-1.01 EXHAUST FAN 120-1 - 3/4 13.8 PH 39 - 20A 1 21112, 1#12GRD. 3/4" 20A 1 - - NOTE#1 EF-1.04 NOT USED - - - - - - - - - - - - - Scale: Job Number: w0Nmpr NIIwrSW NIIIMPIr W W Try'W W/71•1111r W.W W 1110lr W NIGNIP"W W W W W lfP ' IVIWG rr—7miv Now NFory Now07•Pr 7Nw 7iw 7Now 7Now Now Nit:1 1w 1/5"=i'-0^ 52322 CU-1.02 CONDENSING UNIT 208-1 - - 9.1 L 1 B 9,11 - 15A 2 2#12, 1#12GRD. 3/4" 20A 2 - - NOTE#2 North: Drown: AF0 4r ._ 6'8' Chk'd: E5 . RF' JS P1ci[Sale 3/4//PI irk Name,.fi rt.bxg T:\Option Core — Portland OR\Option Core — Portland OR\DWGS\CRD\Elec\eh_rf.dwg 9/13/2017 12:10 PR kmchone Copyright © 2017 by Environmental Systems Design. Inc.