River Terrace East MultifamilyOtak, Inc.
Otak, Inc.
Otak, Inc.
Otak, Inc.
Otak, Inc.
Otak, Inc.
Otak, Inc.
SECTIONVIEW
COVERBACK
PICKHOLEDETAIL
PLANVIEW
SEEDETAIL#110FORMANHOLEFRAMESPECIFICATIONS.
Otak, Inc.
FOAM GASKET W/PSA BACKING(TRIM TO LENGTH)
MOUNTINGFLANGE
DETAIL B
GASKETCOMPRESSEDBETWEEN HOODAND STRUCTURE(SEE DETAIL B)
INSTALLATION NOTE:
POSITION HOOD SUCH THATBOTTOM FLANGE IS BELOWTHE PIPE INVERT.
STAINLESSBOLT
ANCHORSHIELD
EXPANSION CONE(NARROW END OUT)
DRILLEDHOLE
DETAIL A
ANCHOR W/ BOLT(SEE DETAIL A)
18"
GRADE RINGS (2", 4", OR 6")
MAXIMUM 8"- SEE NOTE 6
SET IN NON-SHRINK GROUTPAVING RINGS NOT ALLOWED
SEE NOTE AT TOP OF
STANDARD DETAIL #020.
FOR LARGE DIAMETER
MANHOLES SEE
STANDARD DETAIL #160
PIPE TYPESIZE, AND
CONNECTION
PERPLAN, AS
APPROVED
WATERTIGHT SEAL
OIL & FLOATABLE DEBRIS
ON SURFACE CANNOT EXIT PIPE
"SNOUT" OIL & DEBRIS STOP
ANTI-SIPHON DEVICE
18"
60" MINIMUM
ALL HOODS AND TRAPS FOR CATCH BASINS AND WATER QUALITY STRUCTURES SHALL
BE AS MANUFACTURED BY:
BEST MANAGEMENT PRODUCTS, INC.53 MT. ARCHER RD.
LYME, CT 06371
(860) 434-0277, (860) 434-3195
FAX TOLL FREE: (800) 504-8008
OR (888) 354-7585
WEB SITE: WWW.BESTMP.COM
OR PRE-APPROVED EQUAL
SUMP VOLUME REQUIREMENTS
20 CF/1.0 CFS OF INFLOW
58.9 CF MINIMUM REQUIRED
SUMP VOLUME AVAILABLE MINIMUM MAXIMUM
60" M.H.= 58.9 CF 98.1 CF
72" M.H.= 84.8 CF 141.3 CF
84" M.H.= 115.4 CF 192.3 CF
PROVIDE SPECIAL DETAIL FOR VOLUME
REQUIREMENTS EXCEEDING 192.3 CF
NOTES:
1.ALL MANHOLE SECTIONS SHALL
CONFORM TO THE REQUIREMENTS
OF ASTM C-478 AND APPLICABLE
PROVISIONS OF STD. MANHOLE
DRAWING NO. 010
2.INLET AND OUTLET PIPE NOT TO EXCEED
18"DIA.
3.PROVIDE SPECIAL DETAIL FOR OUTLET FLOW CONTROL EXCEEDING 18" DIA.
4.ALL OUTLETS SHALL HAVE FLOW CONTROL
DEVICE.
Otak, Inc.
NOTE:
ALL COMPACTTION REQUIREMENTS PER
AASHTO T-99 AND ODOT/APWA SPEC 00405.
CONSTRUCTION
1. Water Quality Swale shall be over-excavated and filled to final grade with 12-inch amended
topsoil. Topsoil amendments shall be garden compost, not conventional fertilizer
amendments.
2.A biodegradable Erosion Control Matting shall be placed over the topsoil throughout the
swale cross section, fabric shall be held in place in accordance with the manufacturer's
installation requirements. Anchor spacing shall be based on 3 fps flow over the fabric.
a. Treatment area - high-density jute matting (Geojute Plus or other approved equal)
b. All other areas - low-density jute matting (Econojute or other approved equal)
3.2.5-3 inches of 2"-34" river run rock shall be placed over the matting evenly throughout the
length and width of the swale.
4. Plant materials shall be placed in accordance with the plan and plant table as shown on
approved plans.
5.The water quality swale treatment area plantings can be deemed "substantially complete"
once active green growth has occurred to an average growth of 3" and plant density is an
average of approx. 6 plants (minimum 1-inch plugs or equivalent) per square foot.
6.The facility shall be deemed acceptable to begin the maintenance period when plant growth
and density matches the engineer's design as shown on the approved plans and all other
requirements have been met. The engineer must certify the facility to be functional, in
accordance with the approved plan design to begin the two-year maintenance period.
MAINTENANCE
1.The permittee is responsible for the maintenance of this facility for a minimum of two years
following construction and acceptance of this facility per Chapter 2.
2.Irrigation is to be provided per separate irrigation plan as approved.
Note: Irrigation needs are to be met using a temporary irrigation system with a timer during
the dry season. Systems should be winterized during the wet season to assure longevity and
guard against damage from freezing temperatures. Water source shall be as shown on the
approved plans.
3.Engineer or Owners Representative is to visit and evaluate the site a minimum of twice
annually (Spring and Fall). The landscaping shall be evaluated and replanted as necessary
to ensure a minimum of 80% survival rate of the required vegetation and 90% aerial
coverage. Non-native, invasive plant species shall be removed when occupying more than
20% of the site.
4.The facility shall be re-excavated and planted if siltation greater than 3 inches in depth
occurs within the two-year maintenance period.
NOTES:
1.BAFFLE WALL SHALL HAVE #4 BAR AT 12" SPACING EACH WAY.
2.PRECAST BAFFLE SHALL BE KEYED AND GROUTED IN PLACE.
JOINT BETWEEN CONCRETE BAFFLE AND MANHOLE WALL SHALL BE WATERTIGHT.
3.UPPER FLOW ORIFICE SHALL BE ALUMINUM, ALUMINIZED STEEL OR GALVANIZED
STEEL. GALVANIZED STEEL SHALL HAVE TREATMENT 1.
4.FRAME AND LADDER OR STEPS ARE TO BE OFFSET SO THAT: SHEAR GATE IS VISIBLE FROM THE TOP;
CLIMB-DOWN SPACE IS CLEAR OF RISER AND GATE; FRAME IS CLEAR OF CURB.
5.MULTI-ORIFICE ELBOWS SHALL BE PREINSTALLED TO INSURE LADDER CLEARANCE.
6.RESTRICTOR PLATE WITH ORIFICE AS SPECIFIED IN THE CONTRACT. OPENING IS TO BE
CUT ROUND AND SMOOTH. NEOPRENE GASKET SHALL BE INSTALLED BETWEEN THE
ORIFICE PLATE AND CONCRETE BAFFLE TO PROVIDE A WATERTIGHT SEAL.
7.SHEAR GATE SHALL BE MADE OF ALUMINUM ALLOY IN ACCRDANCE WITH ASTM B 26M AND ASTM B 275,
DESIGNATION Zg32A 0R CAST IRON IN ACCORDANCE WITHASTM A 48, CLASS 30B. LIFT HANDLE MAY BE SOLID
ROD OR HOLLOW TUBING WITH ADJUSTABLE HOOK AS REQUIRED. NEOPRENE RUBBER GASKET RERQUIRED
BETWEEN RISER MOUNTING FLANGE AND GATE FLANGE. MATING SURFACES OF LID AND BODY SHALL BE
MACHINED FOR PROPER FIT. FLANGE MOUNTING BOLTS SHALL BE __" DIAMETER STAINLESS STEEL.
8.SHEAR GATE MAXIMUM OPENING SHALL BE CONTROLLED BY LIMITED HINGE MOVEMENT, STOP TAB
OR SOME OTHER DEVISE.
9.ALTERNATE SHEAR GATES DESIGNS ARE ACCEPTABLE, IF MATERIAL SPECIFICATIONS ARE MET AND FLANGE
BOLT PATTERN MATCHES.
10.MANHOLE CERTIFICATION REQUIRED FOR TRAFFIC LOADING.
NOTE:
GROUT INTERNAL PARTITION AND SEAL ALL CONNECTIONS/ PENETRATIONS TO PREVENT LEAKAGE OF STORM WATER
(WATER TIGHT SEAL) OUT OF NON- APPROVED LOCATIONS.
Otak, Inc.
ENGINEERING DIVISIONPUBLIC WORKS DEPARTMENT
13125 S.W. HALL BLVD.TIGARD, OREGON 97223VOICE: (503) 639-4171FAX: (503) 684-7297
CITY OF TIGARD
OREGON
ENGINEERING DIVISIONPUBLIC WORKS DEPARTMENT13125 S.W. HALL BLVD.TIGARD, OREGON 97223VOICE: (503) 639-4171FAX: (503) 684-7297
CITY OF TIGARD
OREGON
ENGINEERING DIVISIONPUBLIC WORKS DEPARTMENT13125 S.W. HALL BLVD.TIGARD, OREGON 97223VOICE: (503) 639-4171FAX: (503) 684-7297
CITY OF TIGARD
OREGON
ENGINEERING DIVISIONPUBLIC WORKS DEPARTMENT
13125 S.W. HALL BLVD.TIGARD, OREGON 97223VOICE: (503) 639-4171FAX: (503) 684-7297
CITY OF TIGARD
OREGON
ENGINEERING DIVISIONPUBLIC WORKS DEPARTMENT
13125 S.W. HALL BLVD.TIGARD, OREGON 97223VOICE: (503) 639-4171FAX: (503) 684-7297
CITY OF TIGARD
OREGON
ENGINEERING DIVISIONPUBLIC WORKS DEPARTMENT13125 S.W. HALL BLVD.TIGARD, OREGON 97223VOICE: (503) 639-4171FAX: (503) 684-7297
CITY OF TIGARD
OREGON
ENGINEERING DIVISIONPUBLIC WORKS DEPARTMENT
13125 S.W. HALL BLVD.TIGARD, OREGON 97223VOICE: (503) 639-4171FAX: (503) 684-7297
CITY OF TIGARD
OREGON
Otak, Inc.
ENGINEERING DIVISIONPUBLIC WORKS DEPARTMENT
13125 S.W. HALL BLVD.TIGARD, OREGON 97223VOICE: (503) 639-4171FAX: (503) 684-7297
CITY OF TIGARD
OREGON