Loading...
Report PEAI(° Aluminum Railing S� c (13 %okb s SO,C . 2015 International Residential Code Report WARNING No representation or warranty is given that your particular application of these products complies with relevant building codes or that the fasteners provided or used are appropriate for your application. Consult with professionals and local building officials before beginning work: (i)to ensure compliance with relevant building codes for your application and for your proposed use of fasteners; (ii)to ensure the integrity of the structural components in connection with which these products are to be used; (iii)to identify appropriate safety gear that is to be used during installation such as a safety harness when working above ground; (iv) to ensure that the work area is free from utilities, services and hazards; and (v) to clarify any instructions or warnings that may not be clear. Work in a safe manner wearing protective gear such as gloves, eyewear, headwear, footwear and clothing. When using tools comply with operation manuals and instructions. Metal and glass may have sharp edges and could fragment or splinter during or as a result of handling or cutting. Do not use these products in connection with any substance that is or may be harmful or corrosive to the products. Inspect and maintain these products and the structural components that they are used in connection with on a regular basis, using professionals when appropriate. Engineers Peak® Aluminum Railing Engineering Review for Compliance with 2015 International Residential Code Peak Products USA Corporation May 12,2016 RJC No.VAN.106169.0015 Prepared for: Peak Products USA Corporation www.peakproducts.com Prepared by: Read Jones Christoffersen Ltd. 1285 West Broadway,Suite 300 Vancouver BC V6H 3X8 Peak®Aluminum Railing May 12,2016 RJC No.VAN.106169.0015 Engineering Review for Compliance with 2015 International Residential Code Table of CCon en 1.0 OVERVIEW 1 2.0 INFILL ELEMENTS 2 3.0 RAIL ELEMENTS 3 4.0 CONNECTORS 4 0 RESULTS 4 CONCLUSION 5 APPENDIX A:LIST OF COMPONENTS APPENDIX B:ASSEMBLY DRAWINGS Peak®Aluminum Railing May 12,2016 RJC No.VAN.106169.0015 Engineering Review for Compliance with page 1 �. 2015 International Residential Code 1 .0 OVERVIEW The Peak®Aluminum Railing System is intended to act as a guard or barrier to protect the public from a fall. The objectives were to complete a structural review of the structural components based in accordance with applicable material standards and the 2015 International Residential Code. The following specified loads apply: ■ Concentrated load of 200 pounds applied in any direction at any point along the top. • Horizontally applied normal load of 50 pounds on an area equal to 1 square foot. Material resistances will be determined in accordance with the respective design codes AA-ADM-1 Aluminum Design Manual 2015,ASTM E1300-12a Standard Practice for Determining Load Resistance of Glass in Buildings,and 2010 AISC Steel Construction Manual,14th edition. In this report,the following structural components were reviewed: A. Infill Elements 1. Aluminum pickets 16 mm (5/8") wide- Dwg. Title"Aluminum Railing — Railing Assembly with Pickets" 2. Aluminum pickets 38 mm (11/2") wide- Dwg. Title"Aluminum Railing — Railing Assembly with Wide Pickets" 3. Glass panels up to 1.676 m(66")wide— Dwg.Title"Aluminum Railing— Railing Assembly with Glass Panel" 4. " -.a' — • "Aluminum Railing -1-4-aii+ng-Assembly with 6"GlasbPcn ler B. Rail Elements 1 Post— Dwg.Title"Posts" 2. Hand rail —See Report Assembly drawings 3. Base rail — See Report Assembly drawings 4. Stair hand rail —See Report Assembly drawings Peak®Aluminum Railing May 12,2016 RJC No.VAN.106169.0015 Engineering Review for Compliance with page 2 2015 International Residential Code C. Connectors 1. Universal connector— Dwg.Title"Brackets and Connectors" 2. Wall mount brackets— Dwg.Title"Brackets and Connectors" 3. Mid/stair/end fascia mount bracket— Dwg.Title"Fascia Mount Brackets" 4. Corner fascia mount bracket— Dwg.Title"Fascia Mount Brackets" 5. Stair hand and base rail bracket— Dwg.Titles"Aluminum Railing—Stair Railing Assembly with Pickets"and"Aluminum Railing —Stair Railing Assembly with Wide Pickets" The complete list of all components(including non-structural components)for the system is included in Appendix A. 2.0 INFILL ELEMENTS The primary infill elements included: 16 mm (5/8")aluminum picket,38 mm (11/2") aluminum picket,6 mm (1/4")thick glass panels (up to 1.676 m (66")wide),and 8 mm (5/16")thick glass panels (152 mm (6")wide). The review was based on information and drawings provided by Peak Products USA Corporation(Peak) for the elements listed above. Muminum Will Elements Our analysis was based on the following information: • Loads: Prescribed by the 2015 International Residential Code. See Section 1.0,Overview. • Resistance: Completed in accordance with the AA-ADM-1,Aluminum Design Manual 2015. • Section properties: Determined from drawings provided by Peak. Calculations were completed in accordance with AA-ADM-1. • Load configuration: Span and bearing lengths were provided by Peak. Peak®Aluminum Railing May 12,2016 RJC No.VAN.106169.0015 Engineering Review for Compliance with page 3 2015 International Residential Code 2.2 Glass Infill Elements Our analysis was based on the following information: • Loads: Prescribed by the 2015 International Residential Code. See Section 1.0,Overview. • Resistance: Completed in accordance with ASTM E1300-12a, Standard Practice for Determining Load Resistance of Glass in Buildings. ■ Material: Tempered glass in accordance with ASTM E1300-12a per information and drawings provided by Peak. • Section properties: Determined from drawings provided by Peak. • Load configuration: Span and bearing lengths were provided by Peak. • Allowable deflection: The allowable deflection was calculated based on preventing fall-out of the glass from the frame. 3.0 RAIL ELEMENTS 3.1 General Rail Elements The general rail elements include the hand rail, stair hand rail, base rail, and posts. An analysis was completed based on the worst-case configuration for these elements. • Loads: Prescribed by the 2015 International Residential Code. See Section 1.0,Overview. • Resistance: Completed in accordance with the AA-ADM-1,Aluminum Design Manual 2015. - Section properties: Deteimirned fruin drawings provided by Peak. Calculations were completed in accordance with AA-ADM-1. ■ Fastener resistance: Completed in accordance with 2010 AISC Steel Construction Manual. • Load configuration: Span and dimensions were provided by Peak. Posts were modeled as cantilevers,fixed at the base. The results from our analysis show the maximum span that can be achieved,as calculated from the material and fastener resistances. Peak®Aluminum Railing May 12,2016 RJC No.VAN.106169.0015 Engineering Review for Compliance with page 4 2015 International Residential Code 4.0 CONNECTORS 4.1 General Connectors The general connectors included the universal connector, wall mount brackets, mid/stair/end fascia mount bracket, corner fascia mount bracket, and stair hand and base rail brackets. An analysis was completed based on the worst-case configuration for these elements. • Loads: Prescribed by the 2015 International Residential Code. See Section 1.0,Overview. • Resistance: Completed in accordance with the AA-ADM-1, Aluminum Design Manual 2015 and 2010 AISC Steel Construction Manual. • Section properties: Determined from drawings provided by Peak. Calculations were completed in accordance with AA-ADM-1. • Load configuration: Span and dimensions were provided by Peak. • Connections to the base building are not included as part of this review, including but not limited to the rail and post connections. 5.0 RESULTS A full set of calculations and results is presented in RJC #VAN.106169.0015 engineering review package,including: • Dimensioned drawings of each component,including extrusion drawings • Calculation sheets for the structural capacity of components listed in 1.0 Overview The above documents contain proprietary information and as such, have not been included in this report. Peak6 Aluminum Railing May 12,2016 RJC No.VAN.106169.0015 Engineering Review for Compliance with page 5 I. 2015 International Residential Code 6.0 CONCLUSION The Peak®Aluminum Railing System meets the requirements within the 2015 International Residential Code. Limitations of compliance are defined in the assembly drawings presented in •; (40 Yours truly, wQ Gq.BERTJ.RAYNAAD READ JONES CHRISTOFFERSEN LTD. 0 S 4050 �' rn .ese.2°L �'�' STFiUOTUNItt. 1) 0:4; rmen Chun,M.Eng.,P.Eng,LEED®AP Gilbert Raynard,P.Eng.,Struct. ,PE,SE Project Engineer Principal CX/..Tltnc 3.�/!G LPi/hj *The Engineers seal applied to this document is to signify that the work has been reviewed by a Enc. Appendix A— List of Components professional engineer in accordance with the Appendix B —Assembly Drawings standards of practice as required by the authority having jurisdiction. The expiry date on the PE seal is to signify that the work has been performed by the registered professional while their membership was in good standing with the licensing body. The expiry date shown on the seal does not affect the validity of this report in any way. LIMITS RJC prepared this report for the use of Peak Products USA Corporation. The material in it reflects RJC's judgement in light of information available to RJC at the time of preparation,including but not limited to material data sheets,independent testing,and physical mock-ups. Any use that a third party makes of this report,or any reliance or decisions to be based on it,is the responsibility of such third parties. RJC accepts no responsibility for damages,if any,suffered by any third party as a result of decisions made or actions based on this report. This report was prepared for Peak Products USA Corporation. It is not for the use or benefit of,nor may it be relied upon,by any other person or entity,without written permission of Read Jones Christoffersen Ltd. Fr;g�7 rs APPENDIX A LIST OF COMPONENTS Compliance with 2015 International Residential Code Peak Aluminum Railing Page 1 Appendix A-List of Components RJC No.VAN.1O6169.0015 SKU SKU (White) (Black) Description Drawing No. 50000 50001 END POST post-end R2.5 50010 50011 MID POST post-mid R2.5 50020 50021 CORNER POST post-corner R2.5 50050 50051 STAIR POST post-stair R2.5 50100 50101 4'HAND AND BASE RAIL hand-rail R2.2,base-rail R2.2,base-rail-support R2.2 50110 50111 6'HAND AND BASE RAIL hand-rail R2.2,base-rail R2.2,base-rail-support R2.2 50120 50121 8'HAND AND BASE RAIL hand-rail R2.2,base-rail R2.2,base-rail-support R2.2 50112 50113 STAIR HAND&BASE RAIL stair-hand-rail R2.2 50200 50201 4'STANDARD PICKETS AND SPACERS P-S R2.3 50210 50211 6'STANDARD PICKETS AND SPACERS P-S R2.3 50260 50261 6'STANDARD STAIR PICKETS AND SPACERS P-S Stair R2.3 50280 50281 SINGLE STAIR PICKET P-S Stair R2.3 50290 50291 SINGLE NARROW PICKET P-S R2.3 50300 50301 4'WIDE PICKETS AND SPACERS P-S Wide R2.2 50310 50311 6'WIDE PICKETS AND SPACERS P-S Wide R2.2 50360 50361 6'WIDE STAIR PICKETS AND SPACERS P-S Wide Stair R2.2 50380 50381 SINGLE WIDE STAIR PICKET P-S Wide Stair R2.2 50390 50391 SINGLE WIDE PICKET P-S Wide R2.2 50710 50713 6"GLASS PANEL KIT glass-panel-kit R2.2 50820 50820 GLASS PANEL 18" X 36 5/16" glass-panel US R2.2 50823 50823 GLASS PANEL 21"X 36 5/16" glass-panel US R2.2 50830 50830 GLASS PANEL 24" X 36 5/16" glass-panel US R2.2 50833 50833 GLASS PANEL 27"X 36 5/16" glass-panel US R2.2 50840 50840 GLASS PANEL 30"X 36 5/16" glass-panel US R2.2 50843 50843 GLASS PANEL 33" X 36 5/16" glass-panel US R2.2 50850 50850 GLASS PANEL 36"X 36 5/16" glass-panel US R2.2 50853 50853 GLASS PANEL 39"X 36 5/16" glass-panel US R2.2 50860 50860 GLASS PANEL 42"X 36 5/16" glass-panel US R2.2 50863 50863 GLASS PANEL 45"X 36 5/16" glass-panel US R2.2 _ - 508/0 50g70 GLASS PANEL 48-X 36 5/16" glass-panel USR22 50873 50873 GLASS PANEL 51"X 36 5/16" glass-panel US R2.2 50880 50880 GLASS PANEL 54" X 36 5/16" glass-panel US R2.2 50883 50883 GLASS PANEL 57"X 36 5/16" glass-panel US R2.2 50888 50888 GLASS PANEL 60"X 36 5/16" glass-panel US R2.2 50891 50891 GLASS PANEL 63"X 36 5/16" glass-panel US R2.2 50895 50895 GLASS PANEL 66"X 36 5/16" glass-panel US R2.2 50900 50901 UNIVERSAL CONNECTOR ubracket-handrail R2.2,ubracket-baserail R2.2,ubracket-wall R2.2 50902 50903 STAIR HAND AND BASE RAIL BRACKET KIT ubracket-stair-hand-rail R2.2,ubracket-baserail R2.2,ubracket-wall R2.2 50910 50911 BOTTOM RAIL SUPPORT base-rail-support R2.2 50920 50921 WALL MOUNT BRACKETS wall-bracket-hand-rail R2.2,wall-bracket-base-rail R2.2 50940 50940 6'GLASS GASKET glass-gasket-kit R2.2 50960 50961 CORNER FASCIA MOUNT BRACKET fascia-mount-corner R2.2 50970 50971 MID/END/STAIR FASCIA MOUNT BRACKET fascia-mount-mid R2.4 Read Jones Christoffersen Ltd. le! APPENDIX B ASSEMBLY DRAWINGS Compliance with 2015 International Residential Code Peak Aluminum Railing Page 1 Appendix B-Assembly Drawings RJC No. VAN.106169.0015 o MAXIMUM: 86 in [2184 mm] 11111 MAXIMUM: 4 in [102 mm] IL E o, C co z � ill _ 1 Compliance with 2015 International Residential Code Peak Aluminum Railing Page 2 Appendix B-Assembly Drawings RJC No. VAN.106169.0015 MAXIMUM: 86 in [2184 mm] MAXIMUM: 4 in [102 mm] co _ L E E I I C I I 0 1 Compliance with 2015 International Residentia Code Peak Aluminum Railing Page 3 Appendix B-Assembly Drawings RJC No.VAN.106169.0015 n io MA1(IMUM: 74 in [1880 mm] MAXIMUM: 4 in [102 mm L. .......................... .................................................. ............... .................... ... .................................................................... .......................... .................................................................. c E 00 E o N 0 1 /4" (6 mm) TEMPERED GLASS ANSI Z97.1 & CPSC 16 CFR 1201 MAXIMUM: 66 in [1676 mm] MINIMUM: 18 in [457.2 mm] SEE DRAWING BRACKETS AND C SEE DRAWING POSTS Compliance with 2015 International Residential Code Peak Aluminum Railing Page 4 Appendix B-Assembly Drawings RJC No. VAN.106169 0015 o 1ot_ I Jr. a, , �„ MAXIMUM: 74 in [1880 m m] MAXIMUM: 3 % in [96 mm] c op E o 0 5/16" (8 mm) TEMPERED GLASS ANSI Z97.1 & CPSC 16 CFR 1201 E SEE DRAWING BRACKETS AND CON Compliance with 2015 International Residential Code Peak Aluminum Railing Page 5 Appendix B-Assembly Drawings RJC No.VAN.106169 0015 eiC7 ,y. (48‘2/;? 11111 1 ti, /?„/ \II: • • SEE DRAWING: POSTS 6 S.,,) MAXIMUM: 4 in [102 mm111111 r-� STAIR HAND AND BASE RAIL BRACKET KIT Compliance with 2015 International Residential Code Peak Aluminum Railing Page 6 Appendix B-Assembly Drawings RJC No. VAN.106169.0015 :Itil \ 1 ,9� t-\* ti? O `,► • • lit 43 SEE DRAWING: POSTS 6 MAXIMUM: 4 in [102 mm] 111111 STAIR HAND AND BASE RAIL BRACKET KIT Compliance with 2015 International Residential Code Peak Aluminum Railing Page 7 Appendix B-Assembly Drawings RJC No.VAN.106169.0015 101111A—HhilliMA lisialrilliIIIIIMOUNTING 10111111111111111 �� TEMPLATE: 1111111111111 4 1%1A%Noi/ ----------.----------1--.i .1 1 I.; -- — - I- 1:1 1 AA I., 09 32/;? III 1-3/32 in ®\ Compliance with 2015 International Residential Code Peak Aluminum Railing Page 8 Appendix B-Assembly Drawings RJC No. VAN.106169.0015 LEFT MOUNTING CORNER FASCIA IIII TEMPLATE: MOUNT BRACKET SKU: 50960, 50961 3-3/4 in III_ mivi0 MI 4__r"...;" Irraiii" immir ,_ tk 4- A7 1 . MI 0 ME II :1 ur MOUNTING II TEMPLATE: 1-9/32 in 1-9/32 in 0 Y p ��'� - .) N �j Co '� Mi! M N N Compliance with 2015 International Residential Code Peak Aluminum Railing Page 9 Appendix B-Assembly Drawings RJC No. VAN.106169.0015 Ihratill Vii ' 4ii�' 1.406„. �i �'