Report (59)
caO‘S.- oc\`C sup �2t\ok. - 1e'D RECEIVED SEP 5 2018 LDING DIVISION FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 ADVANTAGE SALES AND MARKETING 7104 SW DURHAM RD PORTLAND, OREGON 97224 FIRE PROTECTION EQUIPMENT SUBMITTAL t a 1 w, 0. Worldwide www.tyco-fire.com Fire Pro tection Contacts Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers Description described herein must be installed and maintained in compliance with The TYCO Series TY-FRB,5.6 K-factor, this document, as well as with the Upright (TY313) and Pendent (TY323) applicable standards of the National V i Sprinklers described in this data sheet Fire Protection Association,in addition are quick response,standard coverage, to the standards of any other authori- �` decorative 3 mm glass bulb-type spray ties having jurisdiction. Failure to do so sprinklers designed for use in light or may impair the performance of these ordinary hazard,commercial occupan- devices. , cies such as banks, hotels, and shop The owner is responsible for main ' ping malls. taining their fire protection system The recessed version of the Series and devices in proper operating con- TY-FRB Pendent Sprinkler, where dition. Contact the installing contrac- applicable, is intended for use in areas tor or product manufacturer with any with a finished ceiling. This recessed questions. pendent sprinkler uses one of the following: Sprinkler • A two-piece Style 15 Recessed - t Escutcheon with recessed adjust- Identification } ment up to 5/8 inch (15,9 mm)from Number (SIN) m_ the flush pendent position. • A two-piece Style 20 Recessed TY313 Upright 5.6K,1/2""NPT , Escutcheon with recessed adjust- TY323 Pendent 5.6K, 1/2""NPT ==SE"- a a•. ment up to 1/2 inch (12,7 mm)from the flush pendent position. Technical The adjustment provided by theOperation Recessed Escutcheon reduces the Data accuracy to which the fixed pipe drops The glass bulb contains a fluid which to the sprinklers must be cut. Approvals expands when exposed to heat.When Refer to Table A the rated temperature is reached, the Intermediate level versions of Series fluid expands sufficiently to shatter the TY-FRB Sprinklers are described in Maximum Working Pressure glass bulb, allowing the sprinkler to Technical Data Sheet TFP357. Sprin- 175 psi(12.1 bar) activate and water to flow. kler guards and shields are described 250 psi(17.2 bar)* in Technical Data Sheet TFP78O. *The maximum working pressure of 250 psi(17.2 bar) Design only applies to the listing by Underwriters Laborato- ries,Inc.(UL). Discharge Coefficient Criteria K=5.6 GPM/psi'%(80,6 LPM/bar's=) The TYCO Series TY-FRB,5.6 K-factor, Temperature Rating Upright (TY313) and Pendent (TY323) Refer to Table A Sprinklers are intended for fire protec- IMPORTANT Finishes tion systems designed in accordance Always refer to Technical Data Sprinkler:Refer to Table B with the standard installation rules Sheet TFP700 for the "INSTALLER recognized by the applicable Listing or WARNING" that provides cautions Recessed Escutcheon:White Coated, Approval agency (such as, UL Listing Black Coated,Chrome Plated,or Brass is based on the requirements of NFPA with respect to handling and instal- Plated 13, and FM Approval is based on the lation of sprinkler systems and com- ponents. Improper handling and Physical Characteristics q installation can permanently damage Frame Bronze Data Sheets).Only the Style 15 or Style system or its compo- Button Brass/Copper 20 Recessed Escutcheon is to be used acause the sprinkler to fail Sealing Assembly...Stainless Steel w/TEFLON for recessed pendent installations. a sprinklernts and pBulb Glass to operate in a fire situation or cause Compression Screw Bronze it to operate prematurely. Deflector Bronze Page 1 of 4 JULY 2017 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16" (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* I / 5 o ' 7/16" ■ �= (11,1 mm) tit 1 R4INOMINAL 2Ill CI ���1 I,If F MAKE-IN (50,8 mm) 2 p! ` ym 2" \I if 1-3/8" ��� 3 / (50,8 mm) (34,9 mm) 7 WRENCH FLATS / , olmi.fil,......a• 1/2" NPT** DEFLECTOR* --.— 2-7/8" (73,0 mm)DIA. — CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation Step 2. With pipe-thread sealant �.� applied to the pipe threads, hand- The TYCO Series TY-FRB,5.6 K-factor, tighten the sprinkler into the sprinkler WRENCH RECESS Upright (TY313) and Pendent (TY323) fitting. ,...17.. (USE ONLY Sprinklers must be installed in actor Step 3. Tighten the sprinkler into the END"A") dance with this section. sprinkler fitting using only the W-Type 6 Sprinkler Wrench(Figure 2).With 00.� General Instructions p ( 9 ref- FIGURE 2 Do not install any bulb-type sprinkler erence to Figure 1,apply the W-Type 6 W-TYPE 6 if the bulb is cracked or there is a loss Sprinkler Wrench to the wrench flats. SPRINKLER WRENCH of liquid from the bulb.With the sprin- Torque sprinklers 7 to 14 ft.-lbs.(9,5 to kler held horizontally,a small air bubble 19,0 Nm). should be present.The diameter of the Recessed Pendent Sprinklers WRENCH air bubble is approximately 1/16 inch The Series TY-FRB Recessed Pendent RECESS (1,6 mm)for the 135°F(57°C) and 3/32 Sprinklers must be installed in accor- inch(2,4 mm)for the 286°F(141°C)tem- dance with the following instructions. perature ratings. p --W Step A. After installing the Style 15 A leak-tight 1/2 inch NPT sprinkler or Style 20 Mounting Plate over the joint should be obtained by applying a sprinkler threads,and with pipe-thread minimum to maximum torque of 7 to 14 sealant applied to the pipe threads, �� ft.-lbs. (9,5 to 19,0 Nm). Higher levels hand tightensprinklerfitting.the sprinkler into the `r� of torque can distort the sprinkler Inlet with consequent leakage or impairment PUSH WRENCH of the sprinkler. Step B. Tighten the sprinkler into the IN TO ENSURE sprinkler fitting using only the W-Type GEMENT Do not attempt to compensate for 7 Recessed Sprinkler Wrench (Figure ENGAGEMENT insufficient adjustment in the Escutch- 3).With reference to Figure 1,apply the WITH SPRINKLER WRENCHINGTHAREA eon Plate by under- or over-tightening W-Type 7 Recessed Sprinkler Wrench the sprinkler. Re-adjust the position of to the sprinkler wrench flats. Torque FIGURE 3 the sprinkler fitting to suit. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 W-TYPE 7 RECESSED Upright and Pendent Sprinklers Nm). SPRINKLER WRENCH The Series TY-FRB Upright and Step C. After ceiling installation and Pendent Sprinklers must be installed finishing, slide on the Style 15 or Style in accordance with the following 20 Closure over the Series TY-FRB instructions. Sprinkler and push the Closure over the Step 1.Install Pendent sprinklers in the Mounting Plate until its flange comes in pendent position. Install upright sprin- contact with the ceiling. klers in the upright position. TFP172 Page 3 of 4 Care and 2-7/8" DIA. - (73,0 mm) Maintenance 2-1/4" DIA. The TYCO Series TY-FRB,5.6 K-factor, FACE OF (57,2 mm) Upright (TY313) and Pendent (TY323) SPRINKLER Sprinklers must be maintained and ser- FITTING 5/8"(15,9 mm) viced in accordance with this section. + 1 - FLUSH Before closing a fire protection system 3/8±5/16" main control valve for maintenance (9,5±7,9 mm) 'vwork on the fire protection system } 'that it controls, obtain permission to s).1 18shut down the affected fire protection MOUNTING3,2/mImsystems from the proper authorities SURFACE ( ) and notify all personnel who may be CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) affected by this action. TY-FRB PLATE 3/4"(19,1 mm) Absence of the outer piece of an escutcheon, which is used to cover FIGURE 4 a clearance hole, can delay sprinkler SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) operation in a fire situation. WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only 2-7/8" DIA. _ cleaned by means of gently dusting (73,0 mm) with a feather duster; otherwise, non- FACE OF operation in the event of a fire or inad- SPRINKLER _2-1/4" DIA. _ vertent operation may result. FITTING (57,2 mm) Sprinklers which are found to be 5/16±1/4" leaking or exhibiting visible signs of (7,9±6,4 mm) 1/2"(12,7 mm) corrosion must be replaced. FLUSH Automatic sprinklers must never be =1 painted, plated, coated, or other- wise altered after leaving the factory. t dN 1/8" 1 Modified sprinklers must be replaced. MOUNTING Sprinklers that have been exposed to SURFACE (3,2 mm) corrosive products of combustion, but have not operated,should be replaced if they cannot be completely cleaned CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) by wiping the sprinkler with a cloth or TY-FRB PLATE 7/8"(22,2 mm) by brushing it with a soft bristle brush. FIGURE 5 Care must be exercised to avoid SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) damage to the sprinklers before, WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 during, and after installation. Sprin- RECESSED ESCUTCHEON klers damaged by dropping, striking, wrench twist/slippage,or the like,must Limited Recessed Escutcheon be replaced. Also, replace any sprin- Specify: Style 15 Recessed Escutch- kler that has a cracked bulb or that has Warrant�/ eon with(specify*)finish,P/N(specify*) lost liquid from its bulb. (Ref. Installa- 7 Specify: Style 20 Recessed Escutch- tion Section.) For warranty terms and conditions,visit eon with(specify")finish, P/N(specify*) The owner is responsible for the www.tyco-fire.com. *Refer to Technical Data Sheet TFP770 inspection,testing,and maintenance of their fire protection system and devices Ordering Sprinkler Wrench in compliance with this document, as Specify: W-Type 6 Sprinkler Wrench, well as with the applicable standards Procedure P/N 56-000-6-387 of the National Fire Protection Asso- Specify: W-Type 7 Sprinkler Wrench, ciation (e.g., NFPA 25), in addition to Contact your local distributor for avail- P/N 56-850-4-001 the standards of any other authorities ability.When placing an order, indicate having jurisdiction.Contact the install- the full product name and Part Number ing contractor or product manufacturer (P/N). with any questions. Sprinkler Assemblies with NPT Automatic sprinkler systems are rec- Thread Connections ommended to be inspected, tested, Specify: Series TY-FRB Upright or and maintained by a qualified Inspec- Pendent (specify) Sprinkler, SIN tion Service in accordance with local (specify), K=5.6, Quick Response, requirements and/or national codes. (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). TFP172 Page 4 of 4 SPRINKLER FINISH(See Note 7) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTERc FACTOR COLOR BRASS PLATED 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red (TY313) and 175°F(79°C) Yellow 1,2,3,4,5,6 PENDENT (TY323) 200°F(93°C) Green 5.6 286°F(141°C) Blue 1/2"NPT 135°F(57°C) Orange RECESSED PENDENT 155°F(68°C) Red (TY313) 175°F(79°C) Yellow 1,2,3,4 Figures 4a and 5b 200°F(93°C) Green Notes: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. VdS Approved(For details,contact TYCO Fire Protective Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-54-428-3377.) 6. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. a. Installed with Style 15(1/2"NPT)5/8"Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only.Listings and approvals apply to color(Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/N* 77 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 370 5.6K UPRIGHT(1/2"NPT) TY313 1 NATURAL BRASS 135 135°F(57°C) 371 5.6K PENDENT(1/2"NPT) TY323 3 PURE WHITE(RAL9010)°° 155 155°F(68°C) POLYESTER Use suffix"I"for ISO 7-1 connection; 4 SIGNAL WHITE(RAL9003) 175 175°F(79°C) for example,77-370-4-175-I POLYESTER 5 JET BLACK(RAL9005) 200 200°F(93°C) POLYESTER 9 CHROME PLATED 286 286°F(141°C) **Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2017 Tyco Fire Products,LP. All rights reserved. vice TEFLON is a registered trademark of DuPont vice Protection Products Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems • 1819 Clarkson Road For additional information, C �� uIs ( v�s1A(�tJ��+/} Chesterfield, MO 63017 contact your salesperson today at t BULL MOOSE TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED V FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 11> Acing))company e-mail:salesnbullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 SMITHCooPE INTERNATIONAL Ductile Iron Threaded Fittings Specifications • `** branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP C111)) US • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 44:11;* • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 - 500 . 200 480 250 ¥ 460 ,€ 300 440 350 420 � = 400 400 X41!.. 450 4443 380 :: 500 360 550£ 340 600 320 650 _; 300 1 -; Ductile Iron Fittings- Class 300 UL/FM i'9 ,<... .`. c ® us 4110> APPROVED Fig. 35E 3-90°Elbow LISTED A Size Part Number A Packing Weight IIIIPPfteN in in Inner Master lb 1/2 35E 3004 1.13 100 200 0.2 simik3/4 35E 3006 1.31 70 140 0.3 A 1 35L 3010 1.50 40 80 0.5 IM■; 1-1/4 350 3012 1.75 25 50 0.8 1-1/2 35L 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-112 35E 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow • : B SizeItiA B Packing Weight in Part Number in in Inner Master lb ® 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1,45 50 100 0.4 r i�i VA 1-1(4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RL3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1 52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35HL3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1.1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RL3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Size A Packing Weight Part Number "A in in Inner Master lb /� �, 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 43`50 3010 13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 IA 1-1/2 35F3014 1,44 20 40 1.0 MR 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size A Packing Weight Part Number in in Inner Master lb !��� IA 1,'2 351 3004 1.13 80 160 0.3 3/4 351 3006 1.31 30 60 0.5 w.� 351 3010 50 25 50 0.7 1-1/4 351 3012 1.75 10 20 1.1 if-A ) 1-112 351 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 3513024 2.70 4 8 4.3 j 111 SNIITII-COOPER IN'I'ERNAI'IONAL® • TOLL FREE 1-800-766-0076 • FAX(3231 890-4456 • wwwsmithcooper.com Ductile Iron Fittings- Class 300 UL/FM fir.t. celus APPROVED Fig. 35RT3-Reducing Tee LISTED Size Part Number A B C Packing Weight €; I in in in in Inner Master lb C 3/4 x 1/2 35013006004 1.20 1.20 1.22 60 120 0.4 a , 41 x 1/2 35813010004 1.26 1.26 1.36 30 60 0.6 1 x 1/2 x 1 35R13010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35873010006 1.38 1.38 1.45 25 50 0.6 ( ...,) 1 x 3/4 x 3/4 35013010006006 1.38 1.31 1.45 35 70 0.6 B A 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35813012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35813012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35873012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35R13012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35013012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35873012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35813014004 1.41 1.41 1.66 16 32 1.0 1 1/2 x 1/2 x 1-1/4 35013014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35813014004014 1.94 1.66 1.94 12 24 1.2 1 1/2 x3/4 35013014006 1.52 1.52 1.75 16 37 1.1 1-1/2 x 3/4 x 1-1/4 35013014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1.1/2 35013014006014 1 94 1.75 1.94 18 36 1,2 1-1/2 x 1 35013014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35013014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35013014010010 1.65 1,50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35013014010014 1.94 1.80 1.94 12 24 1.3 a 1-1/2 x 1-1/4 35813014012 1.82 1.82 1.88 12 24 1.4 .' 1-1/2 x 1-1/4 x 1/2 35013014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 314 35R13014012006 1.52 1.45 1.75 16 32 1.0 1-1/7 x 1-1/4 x 1 35813014012010 1.65 1.58 1.80 16 32 1 1 1-1/2 x 1-1/4 x 1-1/4 35813014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4x 1 1/2 35013014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35013020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35073020006 1.60 1.60 1,97 10 20 1.6 2 x 1 35013020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35013020010020 2,25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35013020017020 2,25 2.10 2.25 8 16 2.0 2 x 1-1/2 35R13020014 2.02 2.02 2.16 8 16 2.1 2x 1-1/2x 1/2 35013020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35813020014010 1.73 1.65 2.02 8 16 1.5 2x 1-1/2 x 1-1/4 35R13020014012 1.90 1.82 210 8 16 1.7 2 x 1-1/2 x 1 1/2 35013020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee Size Part Number A in B in C Packing Weight ��; �C in in Inner Master lb 314 x 1 35813006010 1.45 1.45 1.37 30 60 0.6 dib ��=�� 1 x 1-1/4 35813010012 1.67 1.67 1,58 20 40 0.9 � x 1-1/2 35B-1301001480 80 65 13 30 1.0 1-1/4 x 1 x 1-1/2 35813012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-112 35813012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35813012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35013014012020 2.16 2.15 2.02 10 20 1.8 1-1/2 x 2 35813014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.srnincCooper.corn 112 . . '' Ductile Iron Fittings- Class 300 UL/FM -<-/- c ® us APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED 0`2 Size Part Number A Packing Weight in in Inner Master lb ill II _ 1/2 35CP3004 38 200 400 0.1 0.2 1 314 35CP3006 1.63 100 200 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35C03014 2.19 25 50 0.7 2 35083020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling 111 Size A in Inner Master Packing Weight Part Number Inffltin Ib 0.3 A 1 x 1/2 1 x 314 35RC3010004 69 80 160 35R03010006 1.69 60 120 0.4 0.6 1-1/4 x 3/4 35803012006 2.06 40 80 2 x 1 (not hex) 35803020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size A Packing Weight in Part Number in Inner Master lb B 1 x 1/2 35HB3010004 1.06 180 360 02 int'A 1 x 3(4 35HB3010006 1.06 180 360 0.1 1-1/4 x 1 35HB3012.010 1.19 90 180 0.2 I 1 11 1-1/2x 1 35HB3014010 1.25 75 150 0.4 ' 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0 3 2 x 1 35HB3020010 1.38 40 80 0.6 i 2 x 1-1/4 35H83020017 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head Plug Size Part Number A Packing Weight in in Inner Master lb 1/2 35SP3004 0.94 600 1200 0,07 1Ii i IA 3/4 35SP3006 1.12 350 700 0.1 1 1 1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35S83014 1.44 80 160 0,4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat A Size A Packing Weight ti®' in Part Number in Inner Master lb • olmita--_I 1 35U 3010 2.19 20 40 1.0 �ml 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 it®1reigita 2 35U 3020 3.12 6 12 2.4 113 S\IITII-COOPER INTERNATIONAL° • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B3205L - Threaded Rod (right & left hand threads) TL ll1 Size Range: 3/8"-16 thru 3"-4 rod specify Length': Material: Steel � ,, Function: Recommended for use as a hanger support in hanger assemblies. TL Rod is threaded on both ends with right hand threads of the length shown.Also available with left and right hand threads-specify Fig. B3205L when ordering. •' A 9 P fY Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) 83205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) 83205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) 83205-5/8x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 83205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205-11/8 x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) 63205-11/4 x'L' 11/4%7 5" (127.0) 9500 (42.25) 7440 (33.09) 83205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) 03205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 83205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) I ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCo Fig.100) �� Fig. 99 -All Threaded Rod Cut To Length ,A*Avp Size Range: 3/8"-16 thru 11/2"-6 rod in 120" (3.05m)lengths or cut to length � 0 »� Material: Steel _J Al Maximum Temperature: 750°F(399°C) - a Finish: Plain. Contact B-Line for alternative finishes and materials. " 0 0 . Order By: Part number, rod diameter and finish " 11.a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"X 120 99-1/4"X length 20 240 (1.07) 12 (5.44) ATR 3/8"x 120 99-3/8"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 5/8"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"X 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR 7/8"x 12099-7/8".x length 9 4480 (19.93) 170 (77.11) ATR 1"x120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B- Pipe Hangers&Supports Revised 4/28/2014Line 236 by EIT.N Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) TO ' Ca Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) Fig.200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled - swivel nut design permits hanger adjustment after installation. '--.- 411 Features: ® __ - • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe (_ .� types and protect CPVC plastic pipe from abrasion. Captured design r 11 keeps adjusting nut from separating with hanger. Hanger is easily ( s ' installed around pipe. A /I a For hanger with non-captured nut order Fig. 200S. ;, • (21/2" (65mm)thru 8" (2oomm)) Spring tension on nut holds it securely in ' '-.,, ,rz ;;''''' hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) = Fig.200-1/2.200-3/4 in the USA(UL) and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (20omm)). Fig.200-1 to 200-2 Fig.200-21/2 to 200-8 Conforms to Federal Specifications WW-H-171 E&A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 &SP-58, -, Type 10. Maximum Temperature: 650°F 1343°C) Finish: Pre-Galvanized. Stainless Steel ;. materials will be supplied with (21 hex nuts in place of a knurl nut. Order By: Figure number and pipe size 1.` Designed to meet or exceed requirements of ' FM DS 2-0. - .,, Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4' (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (251 3/8"-16 33/8" (85.71 25/8" (66.7) 12 (5.5) . 200-11/4 11/4" 1321 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) r�, 27/8" (73.0) 14 (6.4) 200-11/2 11/2" (40) 3/8" 16 37/8" (98.41 ' /z 21/2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-2 1 (651 ,, 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2", (90) °= 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4' (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 116.0) 200-5 5" (125) :'1:-,-;:-:.':.- 1/2%13 91/8" (231.8) ` ; 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (2001 1/2"-13 131/8" (333.41 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 by VERTICAL MOUNT SAMMYS SAMMYS° for Wood Not less than Wood Flooring 2°nominal width Product Features -1121 ltd 4 •No pre-drilling required. Not lesstnan •Quick to install using the Sammy kesmi2al thickness(2-i12") " Nut Driver with an 18V cordless (depth or side Wood Joist drill/driver. _.` c�`.. of vertical member) - --- - - 7..7_77._,,i—= •Saves time from traditional Double Sheetrock 4 methods. For vertical use- Ceiling kr install in center of lower face. •Reduces installation cost. Minimum 2'"embedment into base , material for NFPA 13 compliance. `Composite/Truss •Made in the U.S.A. Consuiti fti 4actt erfer recommendedinstalation point aa"demey+ t16r GST _; 2r oapee tp. Rod Part Screw Ultimate UL Test FM Test Box Approvals Size Number Model t scixptionsfibs) Load abs) Load fibs} 210(7(18"OSS: �1 1/4" 8002957 GST 100 1/4x1" )� ,,,,,,. 25 125 670(3/4"Ply) s,w� '', (Fir) 25 125 1/4" 8004957 - GST 300 1/4 x 3" 2060 1/4" 8003957 GST 200 1/4 x 2 1760 F ( r) tl 25 125 3/8" 8006957 GST.75 1/4 x 3/4" 564 3/4'Ply) 25 125 210 (7/16'OSB) , 318" 8007957 GST 10 1/4 x 1" +r 25 125 670 (3/4"Ply) — .. 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST 20-SS 1/4 x 2' 1760 (Fir) ,14-, as0 tit,z,'„,..,'",-- 25 125 Q, 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 ` 0 3/8" 8010957 GST 30 1/4 x 3' 2060 (Fir) f 15z. :'1475 ; 25 125 Nut Dry ek 3/8" 8069925 GST 30-SS 1/4 x 3' 2060 (Fir) 25 125 Part#8113910 3/8" 8011925 GST 40 1/4 x 4 2180(Fir) J ,: 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2 1760(Fir)1 41; 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 ( � :�. ; 25 125 1/2" 8015925 GST 3 114x3 2275 (Fir) .a. - 1/2" 8016925 GST 4 1/4 x 4" 2180 (Fir) 25 125 1/2" 8017925 GST 6 114'0 6" 2230(Fir) 25 125 #14 SW Red Nut Driver Part#8114910 SAMMY Swivel Head° for Wood :t1S111F ; ALLYand IT:t/e/s t/, 777 ,,a ?;7 AJC 7 :-/if / u Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. Accommodates up to 3'/:"x 12 pitch roof. •Reduces installation cost •Allows 17°deflection from vertical. •Made in the U.S.A. Approvals Rod Part ,e,,ttet Screw Ultimate' ULTest FM Test tin Box Case Size Number Descriptions Pullout(lbs) Load(lbs) Load ) Thickness Qty Qty 0<2 3/r 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 125 I Q.i'< ' 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 0 ............ .,v ,..,„ For the most up to date information,visit www.sammysuperscrew.com 4 SAMMYS HORIZONTAL MOUNT SIDEWINDERS° for Wood .: Not less than 2 nominal width Product Features (1-1/2")up to 3-1/2"pipe,not less than __ 3"(2-1/2")nominal width 4"8 5"pipe •No pre-drilling required. Fl°or Joist •Quick to install using the Sammy Minimum 2-1/2"from bottom for r Nut Driver with an 18V cordless 1. branch hoes.Minimum 3"from bottom for main lines.Exception:This t~. drill/driver. requirement shall not apply to 2"or thicker nailing strips resting on top of • steel beams. •Saves time from traditional methods. •Reduces installation cost. •Made in the U.S.A. 1. Composite/Truss Consult truss manufacturer for recommended installation point. $_ gym. `Pre-drilling may be required for Model ..... `.'i SWG 25-380(tools available on pg 10). Rod Part Screw Ultimate Ut Test Box Case Approvals Size Number Model Descriptions Pullout s Load(Ms) 1/4" 8018957 SWG 100 1/4 x 1" 622(Fir) 25 125 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 318" 8020957 SWG 10 1/4 x l" 622(Fir) 300 25 125 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 e 3/8" 8073925 SWG 20-SS 1/4 x 2" 1725(Fir) 850 25 125 #14 SW Red q• 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 Nut Driver 3/8" 8023925 SWG 30 1/4 x 3" 1884(Fir) 25 125 Part#8114910 VERTICAL HORIZONTAL 1.Insert the appropriate nut driver into a 3/8"or 1/2"portable drill. 1.Insert the appropriate nut driver into a 3/8"or 1/2"portable drill. 2.Insert the SAMMYS into the#14(black)nut driver(p/n 8113910).Drill 2.Insert the SAMMYS into the#14SW(red)nut driver(p/n 8114910). With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. 3.Push the face of the nut driver tight to the member When the nut driver spins freely on the SAMMYS,stop drill and remove. 3. When the nut driver spins free on the SAMMYS,stop the drill and remove. 4.The SAMMYS is now ready to receive 1/4",3/8",1/2"or metric all thread rod,bolt stock.(The 1/2"requires the#14SW red nut driver) 4.The unit is now ready to receive 1/4",3/8"or metric all thread rod or bolt stock. Note:When installing DSTR,follow the above instructions, then add retainer nut and torque to 20 foot lbs.for maximum Note:When installing SWDR,follow the above instructions,then add retainer nut pullout in purlin steel. and torque to 20 foot lbs.for maximum pullout in purlin steel. 1-....',.:-EE n l ': .I , � K---- SPECIAL NUT DRIVER SYSTEM The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 5 To find a distributor near you,call 800-BUILDEX