Loading...
Plans (48) 40'0• 1 11=11' GARAGE RIGHT IPS =) N R R RS R n n 4 q > > ARI o —f— ASJ1 ASJ1 ASJ2 / ASJ2 . // _ _ , / - 6:12 AH1 (2) //ti AH2 – - AH3 AH4C AH5C AH6 AH7 T - Al (4) AH7 Di _ AH6 6:12 8:12 AH5 —.. AH4 BH3 ilBH2 Bill RH1-(9) lir — D2 (2) ..' CONFORMS TO DESIGN CONCEIT 8 / il ❑ CONFORMS TO DESIGN CONCEI,iITb 10 C8 / :1 6: I 1 '� REVISIONS AS SHOWN t a1 v __ p1M ❑ NON-CONFORMING-REVISE AND RESUBMIT E CONFORMS TO DESIGN CONCEPT v 7 CONFORMS TO DESIGN CONCEPT WITH v 204 1 SHOP DRAWING HAS BEEN R VIEWED FOR GENERAL CONFORMANCE REVISIONS NOTED LV�I TYTH THE DESIGN CONCEPT TV AND DOES NOT RELIEVE THE 0 NON-CONFORMING REVISE&RESUBMIT 91-6' FAEP:DATDP NDGR RESPONS B_LITY FOR CONFORMANCE WITH THE x DESIGN DRAWINGS AND SPECIFICATIONS ALL OF B' H HAVE PRIORITY F ' N. OVER-HIS SHOP DRA;RING. CON PACTOP SHALL VERIFY ALL DIMENSIONS, DRA Y ,'.O - i F OF WH HAVE ASHOE... Al s `R" 4ff A� By: Todd R. Eaton Date: September 19, 2014 BY Alexia F k Date 9/22/14 MILBRANDT ARCHITECTS CT ENGINEERD. ©t �fightCompuTnslnc.2oos BUILDER: ISSUE DATE- ABOVE PLAN PROVIDED FOR TRUSS POLYGON NW 03/31/14 PLACEMENT ONLY.REFER TO TRUSS CALCULATIONS AND ENGINEERED STRUCTURAL PROJECT TITLE: REVISION-1: DRAWINGS INFORMATION.FOR ALL FURTHER PLAN 5-B COO FFER ING DESIGNER/ENG NEER OFRECORD raMin ',..‘ umber RESPONSIBLE FOR ALL NON-TRUSS ' PLAN: DRAWN BY:JP REVISION-2: TO TRUSS CONNECTIONS.BUILDING 5 DESIGNER/ENGINEER OF RECORD TO REVIEW B CHECKED BY: REVIEW ANDDAPPROVE OF ALL & TRUSS ,,,ti COMPANY DELIVERY LOCATION: SCALE: REVISION-3: DESIGNS PRIOR TO CONSTRUCTION. 1/8"= 1' All designs are property of-Pacific Lumber and Truss. All designs are null and void if not fabricated by-Pacific Lumber and Truss. MiTek USA, Inc. l CompuTrus Software Warnings & General Notes WARNINGS: 1. Builder and erection contractor should be advised of all General Notes and Warnings before construction commences. 2. 2x4 compression web bracing must be installed where shown+. 3. Additional temporary bracing to insure stability during construction is the responsibility of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer. 4. No load should be applied to any component until after all bracing and fasteners are complete and at no time should any loads greater than design loads be applied to any component. 5. CompuTrus has no control over and assumes no responsibility for the fabrication,handling,shipment and installation of components. 6. This design is furnished subject to the limitations set forth by TPINVTCA in BCSI,copies of which will be furnished upon request. GENERAL NOTES, unless otherwise noted: 1. This design is based only upon the parameters shown and is for an individual building component.Applicability of design parameters and proper incorporation of component is the responsibility of the building designer. 2. Design assumes the top and bottom chords to be laterally braced at 2'o.c.and at 10'o.c. respectively unless braced throughout their length by continuous sheathing such as plywood sheathing(TC)and/or drywall (BC). 3. 2x Impact bridging or lateral bracing required where shown++. 4. Installation of truss is the responsibility of the respective contractor. 5. Design assumes trusses are to be used in a non-corrosive environment, and are for"dry condition"of use. 6. Design assumes full bearing at all supports shown.Shim or wedge if necessary. 7. Design assumes adequate drainage is provided. 8. Plates shall be located on both faces of truss,and placed so their center lines coincide with joint center lines. 9. Digits indicate size of plate In inches. 10. For basic connector plate design values see ESR-1311,ESR-1988(MiTek). ,4 Y + a `......‘,GINE ' . *, i '� i Vill 94, -z rt: Pik ft i fr!, � � ,,° wry ' acv' 242 ` ) . " el ,tui r r x. EXPIRES 6130115 IIIIIIIIII III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 IC: 2x4 KDDF N18BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2.10=(-958) 2635 3-10=(-318) 336 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(-3001) 1231 10-11=(-697) 2186 10- 4=(-120) 564 WEBS: 2x4 KDDF STAND 3- 4=(-2717) 1165 11.12=(-716) 2136 4-11=(-785) 486 LOADING 4. 5=(-1912) 966 12- 8=(-960) 2567 11. 5=(-551) 1293 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5. 6=(-1912) 966 11- 6=(-785) 486 BC LATERAL SUPPORT <= 12"0C. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-2717) 1165 6.12=(-120) 565 TOTAL LOAD = 42.0 PSF 7- 8=(-3001) 1231 12- 7=(-318) 336 OVERHANGS: 10.0" 10.0" 8. 9=( 0) 42 LL = 25 PSF Ground Snow (Pg) Connector plate prefix designators: C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc BOTTOM CHORD CHECKED FOR A 20 PSF LIMITED STORAGE BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA M,M2OHS,M18HS,M16 = MiTek MT series LIVE LOAD AT LOCATION(S) SPECIFIED BY IBC 2012. LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) THE BOTTOM CHORD DEAD LOAD IS A MINIMUM OF 10 PSF. 0'- 0.0" -276/ 1775V -226/ 226H 5.50" 2.84 KDDF ( 625) 40'- 0.0" -276/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) 'COND. 2: Design checked for net(-5 5sf) uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0,111" MAX LL DEFL = 0.178" @ 20'- 0.0" Allowed = 1.954" MAX TL CREEP DEFL = -0.330" @ 20'- 0.0" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083° MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = 0.070" @ 39'- 6.5" MAX HORIZ, TL DEFL = 0.117" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES 20-00 20-00 NOT EXCEED 19%AT TIME OF MANUFACTURE. T T Design conforms to main windforce-resisting 7-00-05 6-05-13 6-05-13 6-05-13 6-05-13 7-00-05 system and components and cladding criteria. Wind: 140 mph, h=24.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 12 12 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 6.00 / M-4x6 6.00 load duration factor=1.6, 4.0" Truss designed for wind loads 5 "' in the plane of the truss only. M-5x6(S) M -5x 6(S) 3.1' "0.2." 0.25 . e)0 ( v M 1.5x4 + Aik\001,M-1.5x4 0 ...iiiiiii ,, hik. , coM , /AillIllIlkIIIIIik....' f- io/t •0010 16 .25 12 � :o o M-3x6 M-3x4 ° M-3x4 M-3x8 0 M-5x8(S) y y 10-03-04 9-08-12 y 9-08-12 y 10-03-04 y y y y 40-00 0-10 0-10 i JOB NAME : POLYGON PLAN 5-B NFA - Al spate; D-,552 e`0/R 0p �'s WARNINGS: I GENERAL NOTES,unless otherwise noted: 4 e //' 'Y '- 1.Builder and erection contrlactor ah)uld be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual �' {Lh liE 1.- Truss: -' Truss: Al and Warnings before conkiruction commences. building component.Applicability of design parameters and proper2. /1 pbing must be installed where shown+, incorporation of component is the responsibility of the building designer. .f ,/„/ • Additional e responsibility temporary yf r ding to In;ure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY• BS erector.Additional permanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by z compression webra 3. temporary brad I continuous sheathing such as plywood sheathing(TC)and/or drywatl(BC). 'a•r., �, DATE: 7/11/2014 the overall structure is the respon#ibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ -44.......„0„7:44, J.- 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -yy OREGON ^cJ SEQ. : 5 992791 fasteners are complete and at no Mme should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, y� ' A. design loads be applied to any component. and are for"dry condition"of use. / "1/, 2,0 �^- TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 1 fabrication,handling,shipment and installation of components. necessary. (� V P P 7.Design assumes adequate drainage is provided. Pi RI 0- 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both feces of truss,and placed so their center VIII VIII II II IIII VIII IIII VIII III IIII TPI/WTCA in BCSI,copies of which will be furnished upon request. Digit coincideictwith jointcenter nche. 9.Digits indsize of tplate in inches. c MiTek USA,lnc.IConlpuTrua Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES.12/31/2015 IIII III IIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&8TR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2-12=(-1420) 2608 12- 3=( 0) 291 BC: 2x4 KDDF #1&BTR SPACED 24.0" 0.C. 2- 3=(-3048) 1745 12-13=(-1422) 2605 3-13=(-547) 259 WEBS: 2x4 KDDF STAND 3- 4=(-2505) 1688 13.14=(-1231) 2235 13- 4=(-102) 534 LOADING 4- 5=( -597) 766 14-15=(-1231) 2235 13- 6=(-348) 150 IC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 4- 6=(-1683) 1035 15-16=(-1449) 2605 14- 6=( 0) 311 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 5. 7=( -481) 778 16-10=(-1447) 2608 6-15=(-348) 150 TOTAL LOAD = 42.0 PSF 6- 8=(-1683) 1035 8-15=(-102) 534 7- 8=( -597) 766 15- 9=(-547) 259 NOTE: 2x4 BRACING AT 24"OC UON. FOR $ LL = 25 PSF Ground Snow (Pg) 8- 9=(-2505) 1688 9-16=( 0) 291 ALL FLAT TOP CHORD AREAS NOT SHEATHED 9-10=(-3048) 1745 BOTTOM CHORD CHECKED FOR A 20 PSF LIMITED STORAGE 10.11=( 0) 42 LIVE LOAD AT LOCATION(S) SPECIFIED BY IBC 2012. OVERHANGS: 10.0" 10.0" THE BOTTOM CHORD DEAD LOAD IS A MINIMUM OF 10 PSF. BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA M-1.5x4 or equal at non-structural LOCATIONS REACTIONS REACTIONS SIZE SC.IN. (SPECIES) vertical members (uon). 0'- 0.0" -460/ 1775V -197/ 197H 5.50" 2.84 KDDF ( 625) 40'- 0.0" -460/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) Unbalanced live loads have been considered for this design. Connector plate prefix designators: ICOND. 2: Design checked for net(-5 osf) uplift at 24 "oc spacing.] C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 M,M2OHS,M18HS,M16 = MiTek MT series MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.235" @ 22'- 7.4" Allowed = 1.954" MAX TL CREEP DEFL = -0.334" @ 20'- 0.0" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = -0.098" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.123" @ 39'- 6.5" 17-11-11 4-00-10 17-11-11 DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. 7-03-04 6-05-04 4-00 00.05 4-03-03 6-05-04 7-03-04 Design conforms to main windforce-resisting f T f03 0 T T ' T system and components and cladding criteria. 14-00 14-00 Wind: 140 mph, h=23.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, T T T f (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 12 M-4x6 M-4x6 12 load duration factor=1.6, A- 6.00 5� M-3x8. �7 6.00 Truss designed for wind loads in the plane of the truss only. M-4x6 - M-4x6 M-5x6(5) 4. $ N M-5x6(5) 0 0.25" 0"25" E.+) M O o f-- V 1 I rte. r OM I 0 12 13 14 'f 15 16 tt�1 0 o IM-3x8 M-1.5x4 M-3x8 0.25" M-3x8 M-1.5x4 M-3x8 0 M-5x6(S) , , 7-01-08 6-05-04 6-05-04 6-05-04 6-05-04 7-01-08 , > 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-6 NH - AH7 Scale: 0.1547 mac,'`',:' '/,N, yid°0 WARNINGS: GENERAL NOTES,unless otherwise noted: Ct, /X/ f c '-'r 1.Builder and erection contractor should be advised of all General Notes 1.This design Is based only upon the parameters shown and is for an individual .',! ), 11 ,t+',L. Truss: AH 7 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). �.++' ;�! 4 DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3,2x Impact bridging or lateral bracing required where shown++ d >kc�� 4. No load should be applied to any component until after all bracing and 4.Installation of truss Is the responsibility of the respective contractor. -� q_OREGON 4/ SEQ. : 5992792 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, L„ " \ A design loads be applied to any component. and are for"dry Condition"of use. / '1,r r,O - TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if v 14, fir fabrication,handling,shipment and installation of components. necessary. flit" �j 7.Design assumes adequate drainage is provided. -'a.;P R f L-�,- 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 10111111111111111 TPI WTCA in BCSI,copies of which will be furnished upon request. lines dawith jointacenter lines. 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12131/201.5 IIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2.12=(-1076) 2619 12- 3=( 0) 291 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(-3057) 1363 12.13=(-1078) 2616 3.13=(•534) 316 WEBS: 2x4 KDDF STAND 3- 4=(-2492) 1266 13.14=( -957) 2433 13- 4=(-267) 708 LOADING 4- 5=( 0) 0 14.15=( -957) 2433 13- 6=(-540) 250 TC LATERAL SUPPORT <= 12"0C. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 4- 6=(-2136) 1206 15.16=(-1130) 2616 14- 6=( 0) 311 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 8=(-2136) 1206 16-10=(-1128) 2619 6-15=(-539) 250 TOTAL LOAD = 42.0 PSF 7- 8=( 0) 0 8.15=(-268) 708 8- 9=(-2492) 1266 15. 9=(-534) 316 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 9-10=(-3057) 1363 9-16=( 0) 291 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10.11=( 0) 42 BOTTOM CHORD CHECKED FOR A 20 PSF LIMITED STORAGE LIVE LOAD AT LOCATION(S) SPECIFIED BY IBC 2012. OVERHANGS: 10.0' 10.0" THE BOTTOM CHORD DEAD LOAD IS A MINIMUM OF 10 PSF. BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) Connector plate prefix designators: 0'- 0.0" -319/ 1775V -156/ 156H 5.50" 2.84 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 40'- 0.0" -319/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) M,M20HS,M18HS,M16 = MiTek MT series [COND. 2: Design checked for net(-5 osf) uplift at 24 "oc spacing.] VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.209" @ 26'- 0.0" Allowed = 1.954" MAX TL CREEP DEFL = -0.358" @ 20'• 0.0" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = -0.083" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.127" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting 15-11-11 I 8-00-10 15-11-11 system and components and cladding criteria. T f Wind: 140 mph, h=23.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 7-03-04 6-05-04 2-Q3-0S 4-00-05 4-00-05 -03-03 6-05-04 7-03-04 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, 14-00 14-00 inuss thedesiplaneed offor thewind trussoads only. 12 M-4 6 /5 7 M-4x6 12 6.00 / M 6x8 - '',I 6.00 M-5x8(S) � M-5x8(S) v 0,25" 0.25" 0 1b '7o . .+ o0 O O 'L o 1 - 12 13 4 '� 15 1t6 . 1 o I o IM-3x8 M-1.5x4 M+3x8 0.25" M-3x8 M-1.5x4 M-3x8 0 M-5x6(S) 7-01-08 6-05-04 6-05-04 6-05-04 6-05-04 7-01-08 y y y y 0-10 40-00 0-10 R JOB NAME : POLYGON PLAN 5-6 NH - AH6 Scale: 0.1547 ,`t,O Pv O.s .a� WARNINGS: GENERAL NOTES,unless otherwise noted: -t•-Y' 1.Builder and erection contractor Should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual Ll< ♦ 'i+ E f Truss: AH 6 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bra.ing mutt be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to�Inwre stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erectdr.Additionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by �,p ► P h continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,,, '�� DATE: 7/11/2014 the overall structure is the respunt ibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ �J 4�4.� 4. No load should be appiec to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -� ,f-OREGON `ti SEQ. : 5 992793 fasteners are complete and at no lime should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, L- '+7 \ 1f�r�, design loads be applied to any component. and are for"dry condition"of use. / Aly. v. l�.��� fabrication,handling,shipment and installation of components. S" TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if , necessary. // 7.Designassumes adequate ne hdrainage isof truss, � t,,,,,. 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII VIII II I IIII I I IIII II II IIII III TPI/VJrCA in BCSI,copies of which will be furnished upon request. Digit coincide with jointcenterches 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPI RES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2-10=(-931) 2619 10- 3=( 0) 291 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(•3057) 1165 10-11=(-933) 2616 3.11=(-534) 368 WEBS: 2x4 KDDF STAND 3- 4=(-2492) 1038 11-12=(-698) 2433 11- 4=(•241) 708 LOADING 4- 5=(-2136) 1015 12-13=(-698) 2433 11- 5=(-527) 203 IC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5. 6=(-2136) 1015 13-14=(-957) 2616 12- 5=( 0) 311 BC LATERAL SUPPORT <= 12"0C. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-2492) 1038 14- 8=(-955) 2619 5-13=(-527) 203 TOTAL LOAD = 42.0 PSF 7. 8=(-3057) 1164 6-13=(-241) 708 8- 9=( 0) 42 13- 7=(-534) 368 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 7.14=( 0) 291 ALL FLAT TOP CHORD AREAS NOT SHEATHED BOTTOM CHORD CHECKED FOR A 20 PSF LIMITED STORAGE BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA LIVE LOAD AT LOCATION(S) SPECIFIED BY IBC 2012. LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 10.0" 10.0" THE BOTTOM CHORD DEAD LOAD IS A MINIMUM OF 10 PSF. 0'- 0.0" -247/ 1775V -155/ 155H 5.50" 2.84 KDDF ( 625) 40'- 0.0" -247/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) Connector plate prefix designators: C,CN,C18,CN1B (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series ICOND. 2: Design checked for net(-5 nsfl uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L1240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.179° @ 20'• 0.0" Allowed = 1.954" MAX TL CREEP DEFL = -0.358" @ 20'- 0.0" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = 0.076" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.127" @ 39'• 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=22.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 13-11-11 12-00-10 13-11-11 load duration factor=1.6, Truss designed for wind loads T T T T in the plane of the truss only. 7-03-04 6-08-07 6-00-05 6-00-05 6-08-07 7-03-04 12 12 6.00 I 11111411 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1. 2=( 0) 42 2-14=(•1134) 2587 3-14=(•135) 235 BC: 2x4 KDDF #15BTR SPACED 24.0" O.C. 2- 3=(-3022) 1414 14-15=(-1211) 3183 14- 4=(-296) 899 WEBS: 2x4 KDDF STAND 3. 4=(-2812) 1314 15.16=(-1289) 3398 14- 6=(-976) 443 LOADING 4- 5=( 0) 0 16-17=(-1264) 3183 6.15=( -32) 304 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25,0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 4. 6=(-2455) 1236 17.12=(•1187) 2587 15- 7=(-197) 130 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-3285) 1508 7-16=(-197) 130 TOTAL LOAD = 42.0 PSF 7. 8=(-3285) 1508 16- 8=( -32) 304 B-10=(-2455) 1236 8-17=(-976) 443 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 9.10=( 0) 0 10.17=(-296) 899 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10-11=(-2B12) 1314 17.11=(•135) 235 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11-12=(-3022) 1414 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 12-13=1 0) 42 OVERHANGS: 10.0" 10.0" BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP Connector plate prefix designators: AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) M,M2OHS,M18HS,M16 = MiTek MT series 0'- 0.0" -304/ 1775V -111/ 111H 5.50" 2.84 KDDF ( 625) 40'- 0.0" -304/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) ICOND. 2: Design checked for nett-5 psf) uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.273" @ 20'- 0.0" Allowed = 1.954" ' I MAX TL CREEP DEFL = -0.495" @ 20'- 0.0" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0,111" I I I MAX HORIZ, LL DEFL = -0.094" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.146" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19% AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. 11-11-11 16-00-10 11-11-11 Wind: 140 mph, h=22.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, T T '' '' (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 5-01-08 4-07 2-10-0p 5-01-12 5-01-12 2.10-09 4-07 5-01-08 load duration factor=1.6, f f -03-03 ? 2-03-0 T T Truss designed for wind loads 10-00 10-00 in the plane of the truss only. /- 12 5 M-5x6(S) 9 12 6,00 I/ M 4x6 M-6x4 7 0.25" M-3x4 0 4x6 6.00 e, y o M-1.5x4 M- 1.5x4 M M O O d. 1 r« 4N + 3 v 0 14 r 0 'r 'r 1p 17 `1 0 o IM-3x8 M-3x8 �"25" 0.25' M-3x8 M-3x8 0 IM-5x6(S) M-5x6(S) ) ) y ) y > 9-06-12 7-00-01 6-10-05 7-00-01 9-06-12 y y y y 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-B NH - AH4 Spade: Q.,547 �, `c0 PRO s, WARNINGS: GENERAL NOTES,unless otherwise noted: t{(/ C 1:371- Truss: Builder and erection contractor sheuld be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual t,i~ '2411 7 fa• E Truss: AH4 and Warnings before construction commences. building component.Applicability of design parameters and proper " 2.2x4 compression web bracing met be installed where shown+. incorporation of component is the responsibility of the building designer. .,r 3.Additional temporary bracing to In9ure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at ! DES. BY: BS is the responsibility of the erector.Additional permanent bracing of 2'o.c.and at 10'o.c.respectively unless braced throughout their length by Armor Po Y P g continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). �,,++"!",- DATE: 7/11/2014 the overall structure is thr�'respon4ibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 111 >'Cr- . /� 4.No load should be applied to any 4omponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -y { {R�.�d� ! SEW. : 5992795 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, , �lri design loads be applied to any component. and ere for"dry condition"of use. ///��.. '"�}' r�,Q TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if v 14, �5 fabrication,handling,shipment and installation of components. Designneas. �' h_ V P P 7. laesassumescaequaneh drainage i of s {1'R��.. 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center Milli II I 1111 1 Il IIII VIII II II IIII IIII TPI/WTCA in SCSI,copies of which will be furnished upon request. lines coincide with joint center lines. 9. Digits indicate size of plate in inches. c+ MiTek USA,IDC./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES RES:12/31/2015 111101111111 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF N1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2-13=(-1012) 2587 3-13=(-136) 307 BC: 2x4 KDDF N1&BTR SPACED 24.0" 0.C. 2- 3=(-3022) 1237 13.14=( -974) 3183 13- 4=(-275) 899 WEBS: 2x4 KDDF STAND 3- 4=(-2812) 1094 14-15=(-1050) 3398 13- 5=(-976) 397 LOADING 4- 5=(-2455) 1044 15-16=(-1012) 3183 5-14=( -43) 304 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5- 6=(-3285) 1278 16-11=(-1044) 2587 14- 6=(-192) 143 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-3285) 1285 6-15=(-192) 133 TOTAL LOAD = 42.0 PSF 7- 9=(-2455) 1061 15- 7=( -35) 304 8- 9=( 0) 0 7-16=(-976) 389 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 9-10=(-2812) 1112 9-16=(-269) 899 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10.11=(-3022) 1247 16.10=(-136) 293 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11-12=( 0) 42 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. OVERHANGS: 10.0" 10.0" BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA Connector plate prefix designators: AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 0'- 0.0' -241/ 1775V -111/ 111H 5.50" 2.84 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series 40'- 0.0' -245/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) ICOND, 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10,0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = -0.246" @ 20'- 0.0" Allowed = 1.954" MAX TL CREEP DEFL = -0.495" @ 20'- 0.0" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'- 10.0' Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = 0.088" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.146" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19% AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. 0-06-08 1`'( Wind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 9-11-11 19-09-05 10-03 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, 5-01-08 4-10-03 4-10-09 5-01-12 5-01-12 4-07-04 � 4-07 5-01-08 Truss designed for wind loads f in the plane of the truss only. 10-00 T T 6.00 M-4x6 M-3x4 M 5/e X0)25" M-9x4 8 M-4x6 12 6.00 25x4 3 o- 1.5x4 to o o u7 M M -\\ O O ». W 2 v 13 4 fi1p 16 O M-3x8 M-3x8 b.25" 0.25' M-3x8 M-3x8 0 M-5x6(S) M-5x6(S) y J, ), y y y y y 9-06-12 7-00-01 6-10-05 7-00-01 9-06-12 y y 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-B NH - BH3Scale: 0.1481 S,'`" c0rP O ''� WARNINGS: GENERAL NOTES,unless otherwise noted: Gam. �Ghi1J.,r;.l E ..�+., 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual ♦ ."Truss: BH3 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3,Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,,,++ IP.. DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ et /1 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -7 OREGON j4 S E 0 y 4" �s� A. design loads be applied to any component. and are for"dry condition"of use. /nn ).. ,�t} ..> TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the e,Design assumes full bearing at all supports shown.Shim or wedge if V 14, fabrication,handling,shipment and installation of components. necessary. 4/ 7.Design assumes adequate drainage is provided. -'+ )" R'L-�. 6.This design is famished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII VIII VIII IIII I I IIII VIII III IIII TPIPoVECA in SCSI,copies of which will be furnished upon request. git coincide with jointcenterche. 9.Digits indicate size of plate in Inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPI RES:12/31/2015 111111III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 IC: 2x4 KDDF p1&BTR; LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2-13=(-1214) 2654 3-13=( -13) 272 2x6 KDDF H1&BTR T2 SPACED 24.0" O.C. 2- 3=(-3102) 1424 13-14=(-2120) 5340 13- 4=( -309) 975 BC: 2x6 KDDF q1&BTR 3- 4=(•3143) 1441 14.15=(-2516) 6278 13- 6=(-2713) 1079 WEBS: 2x4 KDDF STAND LOADING 4- 5=( 0) 0 15.16=(-2516) 6278 6-14=( -51) 491 LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 4- 6=(-2796) 1339 16-17=(-2432) 5740 14- 7=( -945) 423 TC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-5392) 2262 17-18=(•1207) 2684 15- 7=( 0) 258 BC LATERAL SUPPORT <= 12"OC. UON. TOTAL LOAD = 42.0 PSF 7- 8=(-5741) 2555 18.11=(•1204) 2686 7-16=( -596) 200 8- 9=(•2744) 1321 16- 8=( -11) 311 LL = 25 PSF Ground Snow (Pg) 9.10=(-2748) 1332 8-17=(-3796) 1672 NOTE: 2x4 BRACING AT 24"OC UON. FOR 10-11=(-3111) 1425 17- 9=( -913) 2127 ALL FLAT TOP CHORD AREAS NOT SHEATHED LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11-12=( 0) 42 17-10=( -354) 293 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 10.18=( 0) 180 OVERHANGS: 10.0" 10.0" BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) Connector plate prefix designators: 0'- 0.0" -289/ 1775V -118/ 118H 5.50" 2.84 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 40'- 0.0" -250/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series :COND. 2: Design checked for net(-5 inn uplift at 24 "oc spacing.: VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083' MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.536' @ 19'- 6.0" Allowed = 1.954" MAX TL CREEP DEFL = -0.975" @ 19'- 6.0" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'• 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = •0.097" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.148" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19% AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. 7-11-11 16-10-08 4-10-13 10-03 Wind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-101 T f . (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), f3-00-12 05-0S 4-03-15 7-02-06 5-07.11 4-07-05 4-07-06 5-07-10 load duration factor=1.6, Truss designed for wind loads -05 1 in the plane of the truss only. 6-00 12 12 M-4x6 12 6.001/ 6.001/ 4,p" \I 6.00 9 5 A- o M-5x6 44. M-3X8 M-61 3x8 M-5x16 M-3x4 In• v M-1.5x4 T2 Q�� �0 0 3 + to v CV o � a MN 3 o 1rM-3x8 M-4x12 10.25" M-1155x4 0.2516 M-5x12 M-1185x4 M-3x8 �2 o =M-8x8(S) =M-8x8(S) y ), y , y > > ), , 1' 5-04-12 7-02-06 6-10-14 5-04-03 4-10-13 4-09-02 5-05-14 y y 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-6 NH - BH2 Scale: 0.1481 �c,`� Oi",Nt��C` r WARNINGS: GENERAL NOTES,unless otherwise noted: L{f �� ! (_-r .'$,r p u 1.Builder end erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual ' s rfi 1•"" Truss: B 12 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibilhy of the building designer. 3.Additional temporary bracing to inure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by �r�~ is the responsibility of thelerector.iAdditional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,,i+" !a a DATE: 7/11/2014 the overall structure is the respondibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ y1 Cr' 4. No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. ,y� SEQ. : 5 992797 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, �'L_ "+9 OREGONN As, design loads be applied to any component. and are for"dry condition"of use. /1'h 'IP. 29 4 TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if u �J 1+ , necessary. 4/ n fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. R n,t-. 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center Mill IIII II II IIII III IIII VIII IIII IIII TPI VJrCA in BCSI,copies of which will be furnished upon request. Digit indicate with jointcenterche. 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1888(MiTek) EXPIRES:12/31/2015 1E11411 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS 40-00-00 GIRDER SUPPORTING 6-00-00 FROM 12-00-00 TO 19-00-00 IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR; LOAD DURATION INCREASE = 1.15 (Non-Rep) 1- 2=( 0) 42 2-12=( -958) 5580 3-12=( -120) 766 9-17=(0) 138 2x6 KDDF #1&BTR T2 2- 3=( -6484) 1158 12.13=(-2356) 12824 12- 4=( -390) 2390 BC: 2x6 KDDF #1&BTR LOADING 3- 4=( -6788) 1218 13-14=(-2778) 15096 12- 5=(-7208) 1432 WEBS: 2x4 KDDF STAND LL = 25 PSF Ground Snow (Pg) 4. 5=( -6064) 1108 14-15=(-2778) 15096 5-13=) -330) 2050 TC UNIF LL( 50.0)+DL( 14.0)= 64.0 PLF 0'- 0.0" TO 40'- 0.0" V 5- 6=(-13056) 2488 15-16=(-2114) 12140 13- 6=(-2176) 410 TO LATERAL SUPPORT <= 12"OC. UON. BC UNIF LL( 0.0)+DL( 20.0)= 20.0 PLF 0'- 0.0" TO 12'- 0.0" V 6- 7=(-12140) 2210 16-17=( -754) 4772 14- 6=( -310) 1738 BC LATERAL SUPPORT <= 12"OC. UON, BC UNIF LL( 50.0)+DL( 54.0)= 104.0 PLF 12'- 0.0" TO 19'- 0.0' V 7- 8=( -5222) 946 17.10=( -752) 4772 6-15=(-3278) 800 BC UNIF LL( 0.0)+DL( 20.0)= 20.0 PLF 19'- 0.0" TO 40'- 0.0" V 8- 9=( -5218) 952 15- 7=( -258) 1390 9-10=( -5482) 926 7-16=(-8536) 1596 NOTE: 2x4 BRACING AT 24"OC UON. FOR ADDL: BC CONC LL+DL= 841.0 LBS 0 11'- 8.0" 10-11=( 0) 42 16- 8=( -750) 4348 ALL FLAT TOP CHORD AREAS NOT SHEATHED ADDL: BC CONC LL+DL= 1384.0 LBS @ 19'- 6.0" 16- 9=( -300) 328 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA OVERHANGS: 10.0" 10.0" REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) 0'- 0.0" -629/ 3446V -118/ 118H 5.50" 5.51 KDDF ( 625) Connector plate prefix designators: BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 40'- 0.0" -507/ 2917V 0/ OH 5.50" 4.67 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. M,M2OHS,M18HS,M16 = MiTek MT series ��. ( 2 ) complete trusses required. ICOND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.I Join together 2 ply with 16d Common nails staggered at VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 ** HANGER BY OTHERS TO APPLY CONC. 9" oc in 1 row(s) throughout 2x4 top chords, MAX LL DEFL = 0.000" @ 0'--10.0" Allowed = 0.083" LOAD(S) EQUALLY TO ALL MEMBERS. 9' oc in 2 row(s) throughout 2x6 top chords, MAX TL CREEP DEFL = -0.000" @ 0'--10.0" Allowed = 0.111" 9" oc in 2 row(s) throughout 2x6 bottom chords, MAX LL DEFL = 0.401" @ 19'- 6.0" Allowed = 1.954" + Laterally brace to roof diaphragm. 9" oc in 1 row(s) throughout 2x4 webs. MAX TL CREEP DEFL = -1.255" @ 19'- 6.0" Allowed = 2.606" MAX LL DEFL = 0.000" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.000" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = -0.070" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.166" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19% AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, 5-11-11 18-10-08 4-10-13 10-03 Truss designed for wind loads T '' T T f in the plane of the truss only. f3-00-122-10-15 6-03-15 7-02-06 5-07-11 4-07-05 4-07-06 5-07-10 12 12 M 4x6 12 6.00 I/ 6.00 / �I 6.00 • 4.0" /- 8 'hi/ CD M-5x6 M-3x10 M-36x10 M-5x1 6•� M-3x4 4 ti' M-1.5x4 ,E T2 - a o 3 + L o + + t+, 2, M-3x6 c MN/- o 12 13 '(1/ - - `� 14 4 5 16 17 :1 8 o -1M-3x8 M-5x12 0.25" M-3x6 0.25" M-5x12 M-1.5x4 0 M18HS-7x14(S) ** M18HS-7x14(S) 841# 1384# (4,-.4) 5-04-12 7-02-06 6-10-14 5-04-03 4-10-13 4-09-02 5-05-14 9719 JOB NAME :° POLYGON PLAN 5-B NH - BH1 40-00 Scale: 0.1480-10 RF`Ss� 611111,9 WARNINGS: GENERAL NOTES,unless otherwise noted. 44C.,." .1§ .-f-:- Truss: r 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual •thl Truss: BH 1 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,,++"rte. 1 DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ Ct. 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -; OREGON j4 SEQ. : 5992798 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, �J � \jx IN. and are for"dry condition"of use. .,,>t,_ design loads be applied to any component. , TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if Q 14, <y Q, fabrication,handling,shipment and installation of components. necessary. 1� V 7.Design assumes adequate drainage is provided. -' /`i RI 0- 6.This design Is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 111111111111111111111 TPIANTCA in BCSI,copies of which will be furnished upon request. git coincide with jointacenter lines. 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0,0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2.15=(-1678) 3991 15- 3=(-353) 977 12.23=(0) 242 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(-4625) 1974 15-16=(-1549) 3653 3-16=(-721) 416 WEBS: 2x4 KDDF STAND 3- 4=(-3338) 1493 16-17=(-1176) 2930 16- 4=( -19) 289 LOADING 4- 5=(-2840) 1382 17-18=(•1056) 2757 4.17=(-519) 279 IC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5- 6=( 0) 0 19-20=( 0) 0 17- 5=(-400) 969 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 5- 7=(-2481) 1295 18-20=(-1045) 2776 17- 7=(•640) 312 TOTAL LOAD = 42.0 PSF 7- 8=(-2785) 1416 20.21=(-1031) 2727 7-18=(-153) 492 8- 9=(-2797) 1389 21.22=(-1092) 2794 18- 8=(-182) 325 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 9-11=(-2288) 1229 22-23=(-1136) 2635 20- 8=(•665) 315 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10.11=( 0) 0 23.13=(-1134) 2638 8-21=( -75) 153 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11.12=(•2643) 1300 21- 9=( 0) 216 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 12.13=(-3077) 1361 9-22=(-710) 315 OVERHANGS: 10.0" 10.0" 13-14=( 0) 42 11.22=(-284) 807 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 22-12=(-385) 243 Connector plate prefix designators: AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA M,M2OHS,M18HS,M16 = MiTek MT series LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) 0'- 0.0" -308/ 1775V -133/ 133H 5.50" 2.84 KDDF ( 625) 40'- 0.0" -309/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) ICOND. 2: Design checked for net(-5 osfl uplift at 24 "oc _pacing.] VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" I I MAX LL DEFL = 0.260" @ 16'- 6.2" Allowed = 1.954" MAX TL CREEP DEFL = -0.466" @ 16'- 6.2" Allowed = 2.606" 0-01-05 MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" 13-11-11 12-00-10 13-11-11 MAX HORIZ. LL DEFL = -0.122" @ 39'- 6.5" 2-09 4-05-12 4-05-12 -05-04 6-01-04 2 03-0 L. 6-03-04 MAX HORIZ. TL DEFL = 0.188" @ 39'- 6.5" _ 1 T DESIGN ASSUMES MOISTURE CONTENT DOES 12-00 2-03•0 3-04-13/ 5-05-04 12-00 NOT EXCEED 19%AT TIME OF MANUFACTURE. T T T T Design conforms to main windforce-resisting 12 ♦)1-61x4 10 12 system and components and cladding criteria. f- 6.00 / M-4x6 M- x8 M- x4 M-4x6 Q 6,00 '5 7 1 Wind: 140 mph, h=22.7ft, TCDL=4,2,BCDL=6,0, ASCE 7-10, _, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, M-3X4 Truss designed for wind loads c, 4 M- 3x4 in the planenof the truss only. N- -F %M-4x4 co co M-3x8 3�_%/'� M-3x8 c", O N O Y" �. O �o . o 1 `15 16 '7 16 9 20 2 22 23 ^~�4 0 0 o M-5x8 M-3x4 M-3 x8 'N- x6 0.25' M-3x8 M-1.5x4 C M-3x4+ M-4x10 M 3x42.75 1.89 12 M-5x6(S) 12 09-12 y y y T / > y ), J, y , y-05-0 4-05-12 4-07-08 1,08 -02 6-03-06 6-01-04 5-05-04 6-01-08 , ,, 0 1y0 2-05-08 11-11 ,2-00 23-07-08 0;10 J, y 14-04-08 25-07-08 y y 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-6 NH! {AH5C Scale: 0.1332 0x N O s/ WARNINGS: GENERAL NOTES,unless otherwise noted: ., 'Trus1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 4t- . P;• E c-- Truss: s: AH 5 C and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally t their at DES. BY: BS2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathingsuch as plywood sheathing(TC)and/or d wall BC. :frit a DATE: 7/11/2014 p>� 9R s ry ( ) iI. the overall structure is the.responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ � {t 4. No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -7 ,q�.OREGON ^c7 SEQ. : 5992799 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, L- "+Y k•1**�4A� design loads be applied to any component and are for"dry condition"of use. /h -T V• C;,Y TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if c x 14, S necessary. '11R10-- 6. Q; fabrication,handling,shipment and installation of components. 7. necessary. ss assumes adequate drainage is provided. This design is furnished subject to the limitations set forth by B.Plates shall be located on both faces of truss,and placed so their center 11111111111111111 TPI VJ(CA in BCSI,copies of which will be furnished upon request. it coincide with jointcenterche. 9.Digits indicate size of plate in inches. ee MiTek USA,InC./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:1.2/31/2015 I11E11l II This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 I. 2=( 0) 42 2-13=(-1439) 3991 13- 3=(-29B) 977 9.20=(-264) 807 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(-4625) 1712 13-14=(-1329) 3653 3-14=(-721) 386 20-10=(-387) 302 WEBS: 2x4 KDDF STAND 3. 4=(-3338) 1292 14-15=(-1028) 2930 14- 4=( -14) 289 10.21=( 0) 242 LOADING 4- 5=(-2840) 1155 15-16=) -815) 2757 4-15=(-519) 342 TO LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5- 6=(-2481) 1098 17-18=( 0) 0 15- 5=(-337) 969 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-2785) 1177 16-18=( -812) 2776 15- 6=(-640) 244 TOTAL LOAD = 42.0 PSF 7- 8=(-2797) 1159 18-19=( -802) 2727 6-16=(-161) 492 8- 9=(-2288) 1038 19.20=( -834) 2794 16- 7=(-104) 312 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 9.10=(-2643) 1076 20-21=( -972) 2635 18- 7=(-665) 253 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10.11=(-3077) 1172 21-11=( -970) 2638 7.19=( -55) 136 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11.12=( 0) 42 19- 8=( 0) 216 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 8-20=(-710) 275 OVERHANGS: 10.0" 10.0" BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA Connector plate prefix designators: AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 0'- 0.0" -242/ 1775V -133/ 133H 5.50" 2.84 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series 40'- 0.0" -242/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) ICOND" 2: Design checked for net(-5 psf) uplift at 24 Hoc spacing.) VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.232" @ 16'- 6.2" Allowed = 1.954" MAX TL CREEP DEFL = -0.466" @ 16'- 6.2" Allowed = 2.606" 1 MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'. 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = 0.112" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.188" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19N AT TIME OF MANUFACTURE. 11-11-11 16-00-10 11-11-11 T 1' f Design conforms to main windforce-resisting 2-09 4-05-12 4-08-15 2-01-05 6-01-04 5-04-13 5-08-07 6-03-04 system and components and cladding criteria. 12 2-05-0 T T T 12 f Wind: 140 mph, h=22.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 6.00 I/ M-4x65 M- x4 M-?x8 M-ix4 9M-4x6 6.00 load duration factor=1.6, f Truss designed for wind loads in the plane of the truss only. M-3x4 M 3x4 o + o %M-4x4 3 co M M 3x8 ice_ o o o = o 1 "3 14 15 16 as 8 1 20 21 �tw2 o O o M-5x8 M-3x4 M-3x8 17 0.25'� M-3x8 M-1.5x4 M-3x8 0 M-3x4+ M-5x6 M-4x10 M-5x6(S) M-3x4+ a 2.75 1.89 yp y 12 y 2-09-12)( 1 ), y Jr" y y y-05-09 4-05-12 4-07-08 1,08-0 6-03- 06 6-01-04 5-05-04 6-01-08 , y 0-1p 2-05-08 11-11 y2-00 23-07-08 0y 10 y ), 14-04-08 25-07-08 y y 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-6 NH - AH4C Scale: 0.1499 ��- '���v° `/A� WARNINGS: GENERAL NOTES,unless otherwise noted: ice 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual s h- •f�p I ,II E .c- T r u s s: AH4C and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at ` DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). / 0 DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 1' �CIt. 4SEQ. : 5992800 .No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. OREGON `<7 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, + � TRANS I D: 403334 S. design loads be applied to any component. and are for"dry condition"of use. /nn 'T}• 2,(3 4 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge it c,.+ 14, ,2 fabrication,handling,shipment and installation of components. ney. V 7.Dessessarign assumes adequate drainage is provided. P R 1 L�,. 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 10111111111111111 TPI/WTCA in BCSI,copies of which will be furnished upon request. it coincideictwithizjoint ate in che. 9.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 1E1111111This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2-17=(-1427) 3488 17- 3=( -209) 663 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(•4158) 1779 17-18=(-1262) 3045 17- 4=( -186) 353 1 WEBS: 2x4 KDDF STAND 3- 4=(-3725) 1660 18-19=(-1439) 3656 4-18=( -191) 182 LOADING 4- 5=(-3215) 1467 20.21=( 0) 0 18- 5=( -402) 1134 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5- 6=( 0) 0 19-21=(-1501) 4109 18- 7=(•1196) 523 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 5- 7=(-2846) 1359 21.22=(-1559) 4171 7-19=( -269) 907 TOTAL LOAD = 42.0 PSF 7. 8=(-4286) 1837 22-23=(-1449) 3686 8-19=( -85) 46 8- 9=(-4282) 1836 23-15=(-1108) 2440 19- 9=( -253) 596 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 9.10=(•4019) 1727 21- 9=( -822) 404 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10.11=(-3994) 1670 21-10=( -192) 106 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11-13=(-2515) 1227 10.22=( -310) 220 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 12.13=( 0) 0 22-11=( -80) 536 OVERHANGS: 10.0" 10.0" 13.14=(-2863) 1308 11-23=(•1427) 576 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 14-15=(-2908) 1337 13.23=( -284) 918 Connector plate prefix designators: AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. 15.16=( 0) 42 23.14=( -2) 204 C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M20HS,M18HS,M16 = MiTek MT series BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA JT 15: Heel to plate corner = 2.00" LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) 0'- 0.0" -300/ 1775V -89/ 89H 5.50" 2.84 KDDF ( 625) 40'• 0.0" -301/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) 'COND. 2: Design checked for net(-5 ssf) uplift at 24 "oc spacing.) VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" 9-11-11 20-00-10 9-11-11 MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0,111" MAX LL DEFL = 0.381" @ 21'- 6.8" Allowed = 1,954" T T MAX TL CREEP DEFL = -0.712" @ 21'• 6.8" Allowed = 2.606" 2-08-08 2-03-03 3-0'-04 5-07-13 3-01-02 3-10 MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" T TT ' Q ' T '( T MAX TL CREEP DEFL = -0.001" @ 40'• 10.0" Allowed = 0.111" 2-01-12 2-10-041---0--1 8-05 2-01-12 5-04-05 2-03-0 3-10-08 T 1 1 ' 1t'( 1' ' f f T T '( '' MAX HORIZ. LL DEFL = -0.131" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.207" @ 39'• 6.5" 8-00 1 8-00 DESIGN ASSUMES MOISTURE CONTENT DOES 12 M-5x6(S) 12 NOT EXCEED 19%AT TIME OF MANUFACTURE. 6,00I/ '',1 6.00 Design conforms to main windforce-resisting •3x4' M-3x4 12 system and components and cladding criteria. M 5x6 M-1 5x4 O.a5" =M-4x4 M-4x6 5 7 B 9 kt 11 Wind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, M-3x4 * n (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), v 4 IA-1.5x4 load duration factor=l.6, in M-1.5x4 Ak/141611116.' Truss designed for wind loads n 3 in the plane of the truss only. 0 o M-3x8 �� / no v �� v 1 r 7 �,� 6 o /-o o M 3x8 20 21 23 -1 0 0 o M-3x4+ 1 M-6x10 0.25 M-3x8 M-3x8 o M-3x4+ I M-4x12 2.751.89 o M-5x8(S) 12 ' 12 2-00 5-06-12 6-04-04 1-00-1 y 9-03-04 8-02-04 7-06-12 y yy y y 0-10> 2-00 11-11 y2-00 24-01 0-10 13-11 26-01 1, J, , J, 1, 0-10 40-00 0-10 JOB NAME: POLYGON PLAN 5-6 NH - AH3 PRpfit�rScale: 0.1400 :\c.:1TS--C") .. G.INE'WARNINGS: , GENERAL NOTES,unless otherwise noted: ( � '.Iy 1.Builder and erection contractor sh uld be advised of as General Notes 1.This design is based only upon the parameters shown and is for an individual {3 Truss: AH3 and Warnings before construction ommences. building component.Applicability of design parameters and proper y 2.2x4 compression web braving mut be Installed where shown+, incorporation of component is the responsibility of the building designer. i,.. 3.Additional temporary brac ng to inure stability during construction DES. BY: BS is the responsibility of thelerectgr. dddional permanent bracing of 2.Design assumes the top and bottom chords to be laterally braced at 2'o.c.and at 10'o.c.respectively unless braced throughout their length by �r .�,."' continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). r' " DATE: 7/11/2014 the overall structure is the respon Ibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ d tr 4.No load should be applied to any domponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -$2,:), 0 �(„TO(�f R(/ SEQ. : 5992801 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 4, rti� l., design loads be applied to any component. and are for"dry condition"of use. 0 '`�}A r�,Q �- - TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 14, Ky necessary. `/ t� V fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. r-t F{{,,,,\.• 6.This design Is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center IIIIII VIII II I VIII I II VIII VIII IIII IIIITPI/VJfCA in BCSI,copies of which will be furnished upon request. sgit coincide oind ccae with joint center te lines. 9.Digitsindicate dt size of incInches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-Z 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 • EMI This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #i&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2.15=(-1267) 3488 15- 3=( -161) 663 21-12=(0) 204 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(•4158) 1554 15-16=(•1096) 3045 15- 4=( -173) 353 WEBS: 2x4 KDDF STAND 3- 4=(-3725) 1463 16-17=(-1145) 3656 4.16=( -192) 258 LOADING 4- 5=(•3215) 1216 18.19=( 0) 0 16- 5=( -358) 1134 TC LATERAL SUPPORT <= 12"0C. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5. 6=(•2846) 1133 17-19=(-1245) 4109 16- 6=(-1196) 451 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-4286) 1560 19.20=(-1292) 4171 6-17=( -275) 907 TOTAL LOAD = 42.0 PSF 7- 8=(-4282) 1558 20-21=(-1162) 3686 7-17=( -85) 56 8- 9=(•4019) 1481 21-13=( -978) 2440 17- 8=( -184) 596 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 9-10=(-3994) 1421 19- 8=( -822) 337 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10-11=(-2515) 1026 19- 9=( -182) 104 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11-12=(-2863) 1085 9-20=( -310) 224 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 12-13=(-2908) 1176 20-10=( -84) 536 OVERHANGS: 10.0" 10.0" 13.14=( 0) 42 10.21=(-1427) 518 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 11-21=( -266) 918 Connector plate prefix designators: AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA M,M2OHS,M18HS,M16 = MiTek MT series LOCATIONS REACTIONS REACTIONS SIZE SO,IN. (SPECIES) 0'- 0.0" -235/ 1775V -89/ 89H 5.50" 2.84 KDDF ( 625) JT 13: Heel to plate corner = 2.00" 40'- 0.0" -236/ 1775V 0/ OH 5.50' 2.84 KDDF ( 625) ICOND. 2: Design checked for net(-5 psfl uplift at 24 "oc soacing.l VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = -0.354" @ 21'- 6.8" Allowed = 1.954" MAX TL CREEP DEFL = -0.712" @ 21'• 6.8" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'• 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'• 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = 0.124" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.207" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES 7-11-11 24-00-10 7-11-11 NOT EXCEED 19%AT TIME OF MANUFACTURE. 01-1 3-01-07i �3-01-04 5-07-13 5 04-05 5-01-02 4-01-03 3-10-08 , system and components and cladding criteria. 2-08-08 2-08-05 2 Design conforms to main windforce-resisting -01-112 Wind: 140 mph, h=21.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 12 M-3x4 M-5x6(5) (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 6"00 I/ M-5x6 M-4x6 Q 6.00 load duration factor=1.6, i M- x4 M-1 5x4 0t25" =M-4x4 1 Truss designed for wind loads M-3x4 0 y = 's in the plane of the truss only. v 4 M-1.5x4 M-1.5x4 '''41411114111441%.. � 2 v v co M 3x8 3/ o moo o 15 M 5x10 15 1M7� t.H 145 '«-7V . 4 o 8. o M-3x4+ M-3x8 M-6x10 19 0.250 21 1 M-3x4+ M-3x8 M-3x8 0 1.89 v M-4x12 M-5x8(S) a 2.75 12 J' y 12 )' ), ) y > y y y2-00, 5-06-12 6-04-04 1-00-12, 9- 03-04 8-02-04 7-06-12 y y 0-1y0 2-00 11-11 ,2-00 24-01 Oy 10 y y 13-11 26-01 y 1- 0-10 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-B NH - AH2 Scale: 0.1550 `��` c0/'RO,` DA� WARNINGS: GENERAL NOTES,unless otherwise noted: �( "t' 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual Ct". w 7P s! L. �.1- Truss: AH2 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and vely chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ' DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ �' It 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -�7� 4,"OREGON SEQ. : 5992802 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 1x design loads be applied to any component, and are for"dry condition"of use. //h, ,� �� 1.. TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the e.Design assumes full bearing at all supports shown.Shim or wedge if V p� 14, fabrication,handling,shipment and Installation of components. necessary. '1/ 7.Design assumes adequate drainage is provided. R RI t:. 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII II I VIII IIII I II III VIII IIII IIII TPI/WTCA in BCSI,copies of which will be furnished upon request. git coincide with joint ate in che. 9.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-Z 10.For basic connector plate design values see ESR-1311,ESR-1088(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS 40-00-00 HIP SETBACK 6-00-00 FROM END WALL IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR; LOAD DURATION INCREASE = 1.15 (Non-Rep) 1- 2=( 0) 42 2-14=(-3052) 8834 14- 3=( -652) 2126 10-20=(-562) 1884 2x6 KDDF #1&BTR 72, T3 2- 3=(-10036) 3504 14-15=(-2800) 8048 3.15=( -842) 308 20.11=(-288) 726 BC: 2x6 KDDF #1&BTR LOADING 3- 4=( -7926) 2942 15.16=(-4330) 11250 15- 4=( •860) 2530 WEBS: 2x4 KDDF STAND LL = 25 PSF Ground Snow (Pg) 4- 5=( -7068) 2654 16-17=(-5512) 14076 15- 5=(-4662) 1980 TC UNIF LL( 50.0)+DL( 14.0)= 64.0 PLF 0'- 0.0" TO 6'- 0.0" V 5- 6=(-11444) 4480 17.18=(-5048) 12796 5.16=( -398) 1412 TC LATERAL SUPPORT <= 12"0C. UON. TC UNIF LL( 100.0)+DL( 28.0)= 128.0 PLF 6'- 0,0" TO 34'- 0.0" V 6- 7=(-14240) 5666 18.19=(-5020) 12570 16- 6=(-2954) 1272 BC LATERAL SUPPORT <= 12"OC. UON. IC UNIF LL( 50.0)+DL( 14.0)= 64.0 PLF 34'- 0.0" TO 40'- 0,0" V 7- 8=(-12464) 5012 19.20=(-4110) 10414 6-17=( -414) 1192 BC UNIF LL( 0.0)+OL( 40.0)= 40.0 PLF 0'- 0.0" TO 40'- 0.0" V 8- 9=(-11704) 4500 20-12=(-1888) 5362 17- 7=( -946) 2576 9.10=( -5842) 2162 18- 7=(-2594) 1180 NOTE: 2x4 BRACING AT 24"OC UON. FOR TC CONC LL( 250.0)+DL( 70.0)= 320.0 LBS @ 6'- 0.0" 10-11=( -6516) 2378 18- 8=( -114) 122 ALL FLAT TOP CHORD AREAS NOT SHEATHED TC CONC LL( 250.0)+DL( 70.0)= 320.0 LBS @ 34'- 0.0" 11-12=( -6230) 2234 8-19=(-1142) 820 12-13=( 0) 42 19- 9=( -392) 1702 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 9.20=(-4962) 2222 OVERHANGS: 10.0" 10.0" REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA Connector plate prefix designators: BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. 0'• 0.0" -1152/ 3391V -65/ 6511 5.50" 5.43 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series 40'- 0.0" -1152/ 3391V 0/ OH 5.50" 5.43 KDDF ( 625) __.,_ ( 2 ) complete trusses required. Join together 2 ply with 16d Common nails staggered at 9" oc in 1 row(s) throughout 2x4 top chords, COND. 2: Design checked for net(-5 9sf) uplift at 24 "oc spacing.] 9" oc in 2 row(s) throughout 2x6 top chords, VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 VM 9" oc in 2 row(s) throughout 2x6 bottom chords, MAX LL DEFL = 0.000" @ 0'--10.0" Allowed = 0.083" 9" oc in 1 row(s) throughout 2x4 webs. MAX TL CREEP DEFL = -0.000" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.565" @ 16'- 4.5" Allowed = 1.954" + Laterally brace to roof diaphragm. MAX TL CREEP DEFL = -1.074" @ 16'- 4.5" Allowed = 2.606" MAX LL DEFL = 0.000" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.000" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = -0.137" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.220" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES I NOT EXCEED 19N AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=20.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 5-11-11 28-00-10 5-11-11 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), ( T load duration factor=1.6, T Truss designed for wind loads 2-09 �3-02-11 3-08-05 4-0' 2-03-08 6-02-11 5-11-03 5-06 2-10-153-00-12� in the plane of the truss only. 320# 320# 12 12 M-7x8(S)6.00 L- M-4x10 M-3x8 =M-4x4=M-4x4 0"85") M-3x10 oM-5x6 6.00 �� %M-4x4 '" 5 V iP T3..e,. + M 1.5x4 3 � � V� MoM 3x10o1 `�14 116 ' 17 ' - S9 203 o M-6x8 M-4x10 =M-4x4 =M•10x10 0.25181' M-4x10 M-3x8 0 0 o M-3x4+ a 2.75 M-3x4+ M18HS 7x14 -M-8x8(S) M-3x4+ 12 2.75 o M-3x4+ 2-11-041" y 12 ? y y y y ,, 2- 05-0E 4-06-12 4-05 , 2-00, 9-02-04 9-00-08 5-04-12 , , Oy 1p 2-05-08 11-11 , 2-00 23-07-08 0:19 0-1040-00 0-10 JOB NAME : POLYGON PLAN 5-B NH AH1 Scale: 0.1548 ~`��` Otpicps`. 6`D WARNINGS: GENERAL NOTES,unless otherwise noted: : r J , '�7 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the perimeters shown and is for an individual t�. Truss: AH 1 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown+• incorporation of component Is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY• BS2'o.c.and at 10'o.c.respectively unless braced throughout their length by 4/�"" is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). !a DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ t/ SEQ. : 5992803 iiic 4. No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. it__OREGON fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, may- ". \ design loads be applied to any component, and are for"dry condemn"of use. /0 f'` 1,4 <�.c,.�� TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if V s necessary. t�nn V fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. PAO- 8. 1 - 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII VIII VIII IIII(IIII IIII VIII II I IIII TPIMlrCA in SCSI,copies of which will be furnished upon request. git coincideictwith jointcenter nche. 9.Digitssindsize oplate in inches. ry MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 1E111 IIS This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 9'- 6.0" ICOND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.] IC: 2x4 KDDF N1&BTR LOAD DURATION INCREASE = 1.15 DESIGN ASSUMES MOISTURE CONTENT DOES BC: 2x4 KDDF M1&BTR SPACED 24.0" O.C. NOT EXCEED 19%AT TIME OF MANUFACTURE. TC LATERAL SUPPORT <= 12"00. UON. LOADING Design conforms to main windforce•resisting BC LATERAL SUPPORT <= 12"OC. UON, LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF system and components and cladding criteria, prefix designators: DL ON BOTTOM CHORD = 10.0 PSF Connector plate9 TOTAL LOAD = 42.0 PSF Wind: 140 mph, h=20.4ft TCDL=4.2 BCDL=6.0 ASCE 7-10, C,CN,CI8,CN18 (orrno prefix) = CompuTrus, Inc P M,M2OHS,M18HS,M16 = MiTek MT series LL = 25 PSF Ground Snow (Pg) (All Heights), Enclosed, Cat.2, Exp,B, MWFRS(Dir), load duration factor=1,6, LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL Truss designed for wind loads REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. in the plane of the truss only. BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP Gable end truss on continuous bearing wall UON. M-1x2 or equal typical at stud verticals. AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. Refer to CompuTrus gable end detail for 4-09 4-09 complete specifications. 1' 1' T 12 12 6.00 I/ '-- .I 6.00 IIM-4x4 /- 3 co 0 cm C•3 2 4 CO O,- —/O .:1- 0/— O M-3x4 M-3x4 J., y y y 0-10 9-06 0-10 JOB NAME : POLYGON PLAN 5-B NH - Cl Scale: 0.6187 `�4,V` 0,P,ROre 0 WARNINGS: GENERAL NOTES,unless otherwise noted: Lem : ' t7 rTrus1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual �' y` ttrrr'"SSS 1- Truss: s: Cl and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown+, incorporation of component Is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by » • is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). r. 40000 DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ �' /� 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -yy ,q,OREGON W SE Q ncorrosive environment, � '+7... !� design loads be applied to any component. and are for"dry condition"of use. � ),r 2(} „S(, TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if '1 AQ` fabrication,handling,shipment and installation of components. Dnesign . '' V 7.Design assumes adequate drainage is provided. "' Pi R(1- 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center - - 1111111111111111 TPINYfCA in BCSI,copies of which will be furnished upon request. git coincide with jointain inches.9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:1 2//31/2015 IIIIIIIIIMIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 20'- 6.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF 41&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2- 7=(-252) 1166 3- 7=(-283) 205 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(-1392) 328 7- 8=( -95) 772 7- 4=(-101) 446 WEBS: 2x4 KDDF STAND 3- 4=(-1216) 326 8- 6=(-246) 1169 4- 8=(-101) 450 LOADING 4- 5=(-1218) 339 8- 5=(-287) 206 IC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5- 6=(-1395) 339 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF TOTAL LOAD = 42.0 PSF OVERHANGS: 10.0" 0.0" BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA LL = 25 PSF Ground Snow (Pg) LOCATIONS REACTIONS REACTIONS SIZE SQ,IN. (SPECIES) ** For hanger specs. - See approved plans 0'- 0.0" -143/ 961V -92/ 98H 5.50" 1.54 KDDF ( 625) Connector plate prefix designators: LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 20'- 6.0" -107/ 860V 0/ OH 5.50" 1.38 KDDF ( 625) C,CN,C18,CN16 (or no prefix) = CompuTrus, Inc REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. M,M2OHS,M18HS,M16 = MiTek MT series BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP COND. 2: Design check'd for net -5 rsf u.lift at 24 "oc s.acin.. AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = -0.037" @ 13'- 5.6" Allowed = 0.979" MAX TL CREEP DEFL = -0.075" @ 13'- 5.8" Allowed = 1.306" MAX HORIZ. LL DEFL = 0.016" @ 20'- 0.5" MAX HORIZ. TL DEFL = 0.026" @ 20'- 0.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. T 10-03 T 10-03 Design conforms to main windforce-resisting 5-03-14 4-11-02 4-11-02 5-03-14 system and components and cladding criteria. T T '( T T Wind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 12 12 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 6.00 G . 1 M-4x6 \I 6.00 load duration factor=1.6, 4 Truss designed for wind loads in the plane of the truss only. ii y t M-1.5x4 M-1,5x4 I.0 * + O COLO (h O O a -�� O f- 0 7 +� 8 4,*g O M-3x4 0.25" M-3x4 M-3x4 O M-5x6(S) J, y y y 7-00-03 6-05-11 7-00-03 y ), 0-10 20-06 JOB NAME : POLYGON PLAN 5-B NH . D2 Scale: 0.2933 -\t GIN?,` 'i WARNINGS: GENERAL NOTES,unless otherwise noted: 1 F 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 4X, ;e{ r1 Elf'" Truss: D2 and Warnings before construction commences, building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+. incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to Insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility bili of the'erector. dditional permanent bracingof 2'o.c.and at 10'o.c,respectively unless braced throughout their length by P tY b P continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). „✓�+!!- DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 1/ Ct. 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -� ,y�OREGON j f1 SEQ. : 5 992805 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, I,. -'Y .\ `y"�"� design loads be applied to any component. and are for"dry condition"of use. /0->'�1^" 14, ref,} T TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if necessary. / v tyP fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. R RI 1,- 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 11111111111111 TPI/VYfCA in BCSI,copies of which will be furnished upon request. git coincideindtwith jointnche. 9.Digitssinasize of tplate in inches.li . MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1986(Muck) EXPIRES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 21'- 4.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1,00 TC: 2x4 KDDF M1&BTR; LOAD DURATION INCREASE = 1.15 1-3=(-522) 168 1.5=(-127) 422 3-5=(0) 214 2x6 KDDF N1&BTR T1 SPACED 24,0" O.C. 2-3=( 0) 0 5-4=(-123) 424 BC: 2x4 KDDF #1&BTR 3.4=(•539) 187 WEBS: 2x4 KDDF STAND LOADING LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF IC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA BC LATERAL SUPPORT <= 12"OC. UON. TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN, (SPECIES) 0'- 0.0" -382/ 424V -32/ 34H 137.50" 0.68 KDDF ( 625) LL = 25 PSF Ground Snow (Pg) 20'- 6.0" -68/ 417V 0/ OH 5.50" 0.67 KDDF ( 625) LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 'COND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.' REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 M-1.5x4 or equal at non-structural BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.000" @ 11'- 0.0" Allowed = 0.083" vertical members (uon). AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = 0.000° @ 11'- 0.0" Allowed = 0.111" MAX TL CREEP DEFL = -0.012" @ 15'- 9.0" Allowed = 0.572" Connector plate prefix designators: C,CN,C18,CN18 (or no prefix) = CompuTrus IncMAX TC PANEL LL DEFL = 0.007' @ 13'- 2.0" Allowed = 0.291° M,M2OHS,M18HS,M16 = MiTek MT series Refer to Cdetailus standard gable end detail for complete MAX HORIZ. LL DEFL = 0.003" @ 20'• 0.5" specifications. MAX HORIZ. TL DEFL = 0.005" @ 20'- 0.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19's AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. 10-03 10-03 Wind: 140 mph, h=20.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, - T '( (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 14-03 1-06 4-09 load duration factor=1,6, Truss designed for wind loads 12 =M-4x4+ 12 in the plane of the truss only. /- 6.001/ \I 6.00 a. M-4x6- L 3 o in M-3x4+ M M 0 0 C:. 0 M-3x6 y M-1.5x4 M-3x4 J' M-3x6(S) 11-05-08 15-09 4-09 J• ) y 0-10 20-06 JOB NAME : POLYGON PLAN 5-B NH - D1 Scale: 0,2992 �.,(*), ,S) ° .0 WARNINGS: GENERAL NOTES,unless otherwise noted: 1,� [r iWAIT, . r 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual (,'t. a r7{,Gh Truss: D1 and Warnings before construction commences. building component.Applicability of design parameters end proper 2.2x4 compression web bracing must be installed where shown 5. incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). „.++' ! ,, 40111 DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 4' (� 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -S7 OREGON to SEW. : 5992806 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-conosive environment, r,�1? �. design loads be applied to any component, and are for"dry condition"of use. 4--)6.'7:44" )' _1 TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if �} �I 11r, ty P fabrication,handling,shipment and installation of components. necessary. '�I V 7.Design assumes adequate drainage is provided. ii RIO- 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 111111111111111110111 TPIIVJfCA in BCSI,copies of which will be furnished upon request. git coincide with jointcenterinches.9.Digits indicate size of plate in inches. MiTek USA,InC./CompuTruS Software 7.6.6(1 L)-Z 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/3112015 VIII III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 11'- 8.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2.5=(-40) 429 5.3=(0) 265 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2.3=(-574) 113 5.4=(-40) 429 WEBS: 2x4 KDDF STAND 3.4=(-573) 124 LOADING TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ,IN. (SPECIES) OVERHANGS: 10.0" 0,0" 0'- 0.0" -96/ 594V -50/ 57H 5.50" 0.95 KDDF ( 625) LL = 25 PSF Ground Snow (Pg) 11'- 8.0" -58/ 489V 0/ OH 5.50" 0.78 KDDF ( 625) ** For hanger specs. - See approved plans LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL Connector plate prefix designators: ICOND, 2: Design checked for net(-5 osfl uplift at 24 "oc spacing,) C,CN,CI6,CN16 (or no prefix) = CompuTrus, Inc REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. M,M2OHS,M18HS,M16 = MiTek MT series VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111' MAX TC PANEL LL DEFL = 0.026" @ 8'- 6.3" Allowed = 0.383" MAX TC PANEL TL DEFL = 0.075" @ 8'- 6.3" Allowed = 0.575" MAX HORIZ, LL DEFL = 0.003" @ 11'- 2.5" 5-10 5-10 MAX HORIZ. TL DEFL = 0.006" @ 11'- 2.5" T T 12 12 DESIGN ASSUMES MOISTURE CONTENT DOES 6.00/ M-4X4 \I 6.00 NOT EXCEED 19% AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting 4.0" system and components and cladding criteria. 3/ ,'( �� Wind: 140 mph, h=20.6ft, TCDL=4,2,BCDL=6,0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1,6, Truss designed for wind loads in the plane of the truss only. c•-)0 TO0 0 c%0 M M � �� 1 4 m ��11 �0 ** O M-3x4 I M-1.5x4 M-3x4 i y y ), 5-10 5-10 ,) ) 1, 0-10 11-05 JOB NAME : POLYGON PLAN 5-B NH - E2 Scale: 0.4999 `C.- N" , WARNINGS: GENERAL NOTES,unless otherwise noted: r/ --1 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual I,;� !tq'"•• E (- Truss: E 2 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+. incorporation of component is the responsibility of the building designer. Aile/r 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector.Additionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by T ' Po Y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,,.**!,��" DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 1/' CZ. 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. y OREGON 4 SEQ. : 5992807 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, rl design loads be applied to any component. 5.CompuTrus has no control over and assumes no responsibility for the and are for"dry condition"of use. 6.Design assumes full bearing at all supports shown.Shim or wedge if /. ''� 14 rzQ �." TRANS I D: 403334 . Cy necessary. h � �:+ /'� fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. rl E1�,,,- 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 101111111111111111 TPI/WfCA in BCSI,copies of which will be furnished upon request. Digit coincideictwith jointcenterche. 9. Digits indicate size of plate in inches. MiTek USA,IDC./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPI RES'12/31/2015 1111EIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 11'• 8.0" 'COND. 2: Design checked for net(-5 pst) uplift at 24 "oc spacing.] TC: 2x4 KDDF 41&BTR LOAD DURATION INCREASE = 1.15 DESIGN ASSUMES MOISTURE CONTENT DOES BC: 2x4 KDDF q1&BTR SPACED 24.0" O.C. NOT EXCEED 19%AT TIME OF MANUFACTURE. TC LATERAL SUPPORT <= 12"OC. UON. LOADING Design conforms to main windforce•resisting BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF system and components and cladding criteria. DL ON BOTTOM CHORD = 10.0 PSF Connector plate prefix designators: TOTAL LOAD = 42.0 PSF C,CN,CI8,CN1B (or no prefix) = CompuTrus, Inc Wind: 140 mph, h=20.6ft, TCDL=4,2,BCDL=6,0, ASCE 7.10, M,M2OHS,M18HS,M16 = MiTek MT series LL = 25 PSF Ground Snow (Pg) (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL Truss designed for wind loads REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. in the plane of the truss only. BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP Gable end truss on continuous bearing wall UON. AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY.AND or equal typical at stud verticals. Refer to CompuTrus gable end detail for 5-10 5-10 complete specifications. 12 12 6.00 1/ I I M-4x4 -16.00 /— 3 co C,) 0 c%> co 2 4 co V c. / 1 / ////////1//////////////////f//////////////ll////////7///////////Ill///////////////////J// 5 O O M-3x4 M-3x4 y y ), 0-10 11-08 0-10 JOB NAME : POLYGON PLAN 5-B NH - E1Spate: 0.5949 � // v°cs s., WARNINGS: GENERAL NOTES,unless otherwise noted. 4';' ! +41 rL. � 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual r7{ Truss: E 1 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.24 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. �+ 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at J DES. BY: BS is the responsibility of the erector.Additional 2'o.c.and at 10'o.c.respectively unless braced throughout their length by44100. p y permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). "-a DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 4 ��I, /� 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. 7OREGON 44 S E Q v \(X A. TRANS I D: 403334 design loads be applied to any component, and are for"dry condition"of use. /,,, 'Q,{+ V 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 14, li,. fabrication,handling,shipment and installation of components. necessary. /}. 7.Design assumes adequate drainage is provided. •z�fi R j 0- 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 1111111111111111 TPIMlrCA in BCSI,copies of which will be furnished upon request. git coincide with joint tecenter lines. 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 1 0.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 1 , 1111111111 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS 6-00-00 GIRDER SUPPORTING 20-06-00 IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 (Non-Rep) 1-2=(-125) 101 1.4=(-54) 72 2-4=(-187) 169 BC: 2x8 KDDF N1&BTR2-3=( -10) 5 WEBS: 2x4 KDDF STAND LOADING LL = 25 PSF Ground Snow (Pg) TC LATERAL SUPPORT <= 12"OC. UON. TC UNIF LL( 50.0)+DL( 14.0)= 64.0 PLF 0'- 0.0" TO 6'- 0.0" V BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA BC LATERAL SUPPORT <= 12"OC. UON. BC UNIF LL( 231.2)+DL( 177.2)= 408.5 PLF 0'- 0.0" TO 6'- 0.0" V LOCATIONS REACTIONS REACTIONS SIZE SQ.IN, (SPECIES) 0'- 0.0" -304/ 1451V -41/ 104H 5.50" 2.32 KDDF ( 625) Single member as shown. LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 6'- 0.0" -302/ 1384V 0/ OH 5.50" 2.21 KDDF ( 625) Hangers attached to the bottom chord REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. will have 1.5" max, nail penetration. BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP COND, 2: Design checked for net -5 rsf u.lift at 24 "oc sracint. ** For hanger specs. - See approved plans AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 Connector plate prefix designators: MAX TC PANEL LL DEFL = 0.089" @ 3'- 0.4" Allowed = 0.323" C,CN,CI8,CN18 (or no prefix) = CompuTrus, Inc MAX TC PANEL TL DEFL = -0.097" @ 3'• 0.5" Allowed = 0.484° M,M2OHS,M18HS,M16 = MiTek MT series 5-08-04 0-03-12 3 T 2 MAX HORIZ. LL DEFL = 0.000" @ 5'- 8.2" MAX HORIZ. TL DEFL = 0.000" @ 5'- 8.2" 12 DESIGN ASSUMES MOISTURE CONTENT DOES 6.00I/ NOT EXCEED 19b AT TIME OF MANUFACTURE. M-1.5x4 Design conforms to main windforce-resisting , i 3 -/ system and components and cladding criteria. Wind: 140 mph, h=20.7ft, TCDL=4.2,BCDL=6.0, ASCE 7.10, i (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, Truss designed for wind loads in the plane of the truss only. Ch O 0 O M I o/- 111111111111111111111111111111111 o/- 10--=--0_ ** 4 M-5x16 I M-3x10 > y ), 5-08-04 0-03-12 6-''A0 JOB NAME : POLYGON PLAN 5-B NH - Fl -GIRD Scale: 0.5462 � `�'PR0r s WARNINGS: GENERAL NOTES,unless otherwise noted: `S `-Tru1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual It.1:, E .1.- Truss: ss: Fl -GIRD and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the budding designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at 2'o.c.and at 10'o.c.respectively unless braced throughout their length by ,Irs^"' DES. BY: BS Is the responsibility of the erector.Add Tonal pe manent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). -- `!m' DATE: 7/11/2014 the overall structure is the respondibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 4. No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -Sy OREGON j4 SEQ. : 5992809 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are lobe used in a non-corrosive environment, 4- + r 1A design loads be applied to any component, and are for"dry condition"of use. / '41P" 2, -.> TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if �I 14, A fabrication,handling,shipment and installation of components. DesignDeasscessary. "' y P P 7. laesassumes adequate ne dthifac a is truss, j R �-. 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII I I VIII IIII IIII II VIII III III TPIANrCA in BCSI,copies of which will be furnished upon request. git coincideictwith jointanr lines. e.Digits indicate size of plate in inches. MiTek USA,IDC./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS 6-00-00 GIRDER SUPPORTING 11-08-00 IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 (Non-Re BC: 2x8 KDDF #1&BTR ( on- p) 1-2=(-125) 101 1-4=(•54) 72 2.4=(-187) 169 WEBS: 2x4 KDDF STAND LOADING 2.3=( -10) 5 TC LATERAL SUPPORT <= 12"OC. UON. TC UNIF LL( 50.0)+DL(L =14.0)=F G64.0dPLFcw 0'- 0.0" TO 6'- 0.0" V BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA BC LATERAL SUPPORT <= 12"OC. UON. BC UNIF LL( 120.8)+DL( 102.2)= 223.0 PLF 0'- 0.0" TO 6'- 0.0" V LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) Single member as shown. 0'- 0.0" -170/ 881V -41/ 104H 5.50" 1.41 KDDF ( 625) Hangers attached to the bottom chord LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 6'- 0.0" -175/ 841V 0/ OH 5.50" 1.35 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. will have 1.5" max. nail penetration. ** For hanger specs. - See approved plans BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP COND. 2: Design checked for net(-5 re) uplift at 24 "cc spacing.' AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 Connector plate prefix designators: MAX TC PANEL LL DEFL = 0.089" @ 3'- 0.4" Allowed = 0.323" C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc MAX TC PANEL TL DEFL = -0.097" @ 3'- 0.5" Allowed = 0.484° M,M2OHS,M18HS,M16 = MiTek MT series 5-08-04 0-03-12 MAX HORIZ. LL DEFL = 0.000' @ 5'- 8.2' T T T MAX HORIZ. TL DEFL = 0.000° @ 5'- 8.2" 12 DESIGN ASSUMES MOISTURE CONTENT DOES 6.00 / NOT EXCEED 19%AT TIME OF MANUFACTURE. M-1.5x4 Design conforms to main windforce-resisting 3 system and components and cladding criteria. Wind: 140 mph, h=20.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, m (All Heights), Enclosed, Cat.2, Exp.6, MWFRS(Dir), load duration factor=1.6, Truss designed for wind loads in the plane of the truss only. co 0 v 0 ® JI � -o M-5x16 M-3x10 ** y y ), 5-08-04 0-03-12 y y 6-00 JOB NAME : POLYGON PLAN 5-B NH - F2-GIRD Scale: 0.5462 O P °p1�6'6' WARNINGS: GENERAL NOTES,unless otherwise noted: CJ //,/ "T "tri` 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual {r{{'` y, G 1, E (. Truss: F2-GIRD and Warnings before construction commences. building component.Applicability of design parameters and proper G 2.2x4 compression web bracing must be installed where shown v, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywooding(TCand/or drywall(BC). 4�► 4r� DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing requiredmeed where shown++ CC 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. # OREGON ff,-- SEQ. : 5992810 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, �� , lx W design loads be applied to any component. and are for"dry condition"of use. "�, . TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if /6 *II' 14 2 nfabrication,handling,shipment and installation of components. Design ecessary. ��. 7.PlaI s assumes aded on edth drainage iso sed M rl(t..`" 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center +�l I VIII VIII VIII VIII VIII VIII VIII IIII IIIITPI/WfCA in BCSI,copies of which will be furnished upon request. lines coincide with joint center lines. 9.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 8'- 8.9" ICOND. 2: Design checked for net(-5 psf) uplift at 24 "oc soacina.] IC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 DESIGN ASSUMES MOISTURE CONTENT DOES BC: 2x4 KDDF M1&BTR SPACED 24.0" O.C. NOT EXCEED 19%AT TIME OF MANUFACTURE. TC LATERAL SUPPORT <= 12"0C. UON. LOADING Design conforms to main windforce-resisting BC LATERAL SUPPORT <= 12'OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF system and components and cladding criteria. Connector plate prefix designators: TOTAL LOAD = 42.0 PSF Wind: 140 mph, h=15ft, TCDL=4.2,BCOL=6.0, ASCE 7-10, C,CN,CI8,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = Malek MT series LL = 25 PSF Ground Snow (Pg) (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir),load duration factor=1.6, LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL Truss designed for wind loads REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. in the plane of the truss only. Gable end truss on continuous bearing wall UON. BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP M-1x2 or equal typical at stud verticals. ' AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. Refer to CompuTrus gable end detail for 4-04-08 4-04-07 complete specifications. '1 T '( 12 12 6.00 I/ \I 6.00 IIM-4x4 3 f- 1 I I-- 0 `O CO O Cd 4 M CO -/O O �/ 1 _ _ _ _ O 0 //////////////////////////////////////////////////////////////////// O M-3x4 M-3x4 J., y y 0-10 I 8-08-15 JOB NAME: POLYGON PLAN 5-6 NH - G1 Scale: 0.6079 �, ,,,o)/PN OFA� , WARNINGS: GENERAL NOTES,unless otherwise noted: f/ ,�qqI. __ 1.Builder and erection contractor st(ould be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual C 7L 0* E Yr. Truss: G1 and Warnings before construction commences. building component.Applicability of design parameters and proper ,/� incorporation of component is the responsibility of the building designer. / 2.2x4 compression web bracing muBt be Installed where shown+, 2.Design assumes the top and bottom chords to be laterally braced at ,/�" DES. BY' BS 3.Additional temporary bracing to ir{�ure stability during construction 2'o.c,and at 10'o.c.respectively unless braced throughout their length by 0401w is the responsibility of th�erector(Additional permanent bracing of continuous sheathingsuch as plywood sheathing(TC)(TC and/or d wall BC. ! DATE: 7/11/2014 p g s ryO /�' the overall structure is th respo ability of the building designer. 3.2z Impact bridging or lateral bracing required where shown++ SEQ. : 5992811 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -Y7 ,,,,��++OREGON .4y fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 1.- 4, ZEA, A. design loads be applied to any component, and are for"dry condition"of use, 14, TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge f 4,8'�r CC�� S� necessary. 4,8'r�R �.-` fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. 6.This design Is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 1111111111111121 TPI WfCA in BCSI,copies of which will be furnished upon request. git coincide with jointche. 9. Digitssdsize of tplate in inches.li . MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1888(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 5'- 3.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2-4=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2-3=(-63) 29 TO LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 14,2" 0.0" TOTAL LOAD = 42.0 PSF 0'- 0.0" -77/ 404V 0/ 66H 5.50" 0.65 KDDF ( 625) 5'- 0.2" 0/ 64V 0/ OH 5.50" 0.10 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 5'- 3.0" -58/ 140V 0/ OH 1.50" 0.22 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. ICOND, 2; Design checked for net(-5 osf) uplift at 24 "oc spacing.( VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.005" @ -1'- 2.2" Allowed = 0.119" AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.005" @ -1'- 2.2" Allowed = 0,158" MAX TC PANEL LL DEFL = 0.037" @ 3'- 2.1" Allowed = 0.303" MAX TC PANEL TL DEFL = -0.046" @ 3'- 0.0" Allowed = 0,454" MAX HORIZ. LL DEFL = -0,000" @ 5'- 2.2' 12 MAX HORIZ. TL DEFL = -0.000" @ 5'- 2.2" 4.00 V 3 DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19% AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. A Wind: 140 mph, h=loft, TCDL=4,2,BCDL=6.0, ASCE 7-10, Lr) (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, o Truss designed for wind loads o in the plane of the truss only. M-3x4 N cn0 cV 1 2 4 `\ J, y 1-02-04 (PROVIDE FULL BEARING;Jts:2,4,3I 5-03 JOB NAME : POLYGON PLAN 5-B NH - G3Sala: 0.7536 ' PRQ s, WARNINGS: GENERAL NOTES,unless otherwise noted: "!•` 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an Individual 4CI( . E yam" Truss: G3 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+. incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at >� DES. BY: BS2'o.c.and at 10'o.c.respectively unless braced throughout their length by rrmlr is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). �, rt�ir! 'ems" DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ * ft /� 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -� OREGON 4t/ S E Q . h1), TRANS I D: 403334 design loads be applied to any component. and are for"dry condition"of use. / }r V .J�.- 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 1 , fabrication,handling,shipment and installation of components. necessary. C 7.Design assumes adequate drainage is provided. Fi R 1�..�^" 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 1111111111111111111 TPI VYfCA in BCSI,copies of which will be furnished upon request. git coincideiindicate with jointcenterche. 9.Digits indicate size of plate in inches. C MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPI RES:12/31112015 111 IIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 5'- 3.0" [COND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.' TC: 2x4 KDDF k1&BTR LOAD DURATION INCREASE = 1.15 DESIGN ASSUMES MOISTURE CONTENT DOES BC: 2x4 KDDF #1&BTR SPACED 24.0" 0.C. NOT EXCEED 19%AT TIME OF MANUFACTURE. TC LATERAL SUPPORT <= 12"OC. UON. LOADING Design conforms to main windforce-resisting BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+OL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF system and components and cladding criteria. Connector plate prefix designators: TOTAL LOAD = 42.0 PSF Wind: 140 mph, h=15ft, TCDL=4.2,BCDL=6.0, ASCE 7.10, C,CN,CI8,CNI8 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LL = 25 PSF Ground Snow (Pg) (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir),load duration factor=l,6, LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL Truss designed for wind loads REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. in the plane of the truss only. BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD, TOP Gable end truss on continuous bearing wall UON. AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY.AND or equal typical at stud verticals. Refer to Compu7rus gable end detail for complete specifications. 12 4.00 1. 3 Lo 0 woordill01.11.11111..1111111.11.11111.1111 0 CV 2 r/— co 4 M-8x4' 1. ), 1, 1-02-04 5-03 JOB NAME : POLYGON PLAN 5-B NH' - G2 Spade: 0.7728 �c� � QGIN/.11 Cg's, WARNINGS: GENERAL NOTES,unless otherwise noted. C 1;. �-��± 1.Builder and erection cont ctor sh ukl be advised of all General Notes 1.This design is based only upon the parameters shown end is for an individual (t. e• L Truss: G2 and Warnings before con$tructign ommences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing mu be installed where shown+, incorporation of component is the responsibility of the building designer. .,,r ' 3.Additional temporary bra ng to In ure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at ✓' DES. BY: BS is the responsibility of the erector. dditionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by f/r " P tY continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). MINN!, DATE: 7/11/2014 the overall structure is tho respon'bility of the building designer. 3.2x Impact bridging or lateral bracing required where shown vu 441 �>kc�� 4. No load should be applied to any omponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -� OREGON `sr SEQ. : 5992813 fasteners are complete and at no dme should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, r, A. design loads be applied to any component. 5.Compu7rus has no control over end assumes no responsibility for the and are for"dry condition"of use. ///��.. 'T}' '14, .... 2Q TRANS I D: 403334 6.Design assumes full bearing at all supports shown.Shim or wedge if c pp 14, A necessary. p V� fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. 4:r"j RIO, 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 101 (IIII 11II IIII VIII IIII Hint IIII TPIM?CA in BCSI,copies of which will be furnished upon request. git coincide with jointanr lines. 9.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTfus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 111111111 1111HIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 7'- 1.5" IBC 2012 MAX MEMBER FORCES 4WR/ODF/Cq=1.00 TC: 2x4 KDDF R1&BTR LOAD DURATION INCREASE = 1.15 1.2=(-94) 79 1-4=(-44) 58 2.4=(-233) 166 BC: 2x4 KDDF N1&BTR SPACED 24.0" O.C. 2.3=(-10) 4 WEBS: 2x4 KDDF STAND LOADING TC LATERAL SUPPORT <= 12"OC. DON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) TOTAL LOAD = 42.0 PSF 0'- 0.0" -34/ 292V -30/ 80H 4.00" 0.47 KDDF ( 625) Connector plate prefix designators: 7'- 1.5" -37/ 307V 0/ OH 5.50" 0.49 KDDF ( 625) C,CN,C18,CN1B (or no prefix) = CompuTrus, Inc LL = 25 PSF Ground Snow (Pg) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL [COND. 2: Design checked for net(-5 psfl uplift at 24 "oc spacing.' REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX TC PANEL LL DEFL = 0.152" @ 3'- 5.5" Allowed = 0,408" BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX TC PANEL TL DEFL = -0.202" @ 3'- 5.7" Allowed = 0.612" AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX HORIZ. LL DEFL = 0.000" @ 6'- 7.7" 6-07-12 0-05-12 MAX HORIZ. TL DEFL = 0.000" @ 6'- 7.7' T 12 DESIGN ASSUMES MOISTURE CONTENT DOES 4.00 NOT EXCEED 199s Al TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. M-1.5x43 140 mph, h=15ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 3 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), m 2 load duration factor=1.6, Truss designed for wind loads in the plane of the truss only. U, CO O N n / O .1- 11111111111111111111111111111111111111111111111111111111111111111 p mW 0 1►� ►�4 M-3x4 M-1.5x4 > y 1, 6-07-12 0-05-12 y y 7-01-08 JOB NAME : POLYGON PLAN 5-B NH - G4Sale: 0.5566 `� N'' ° rre9 WARNINGS: GENERAL NOTES,unless otherwise noted: //// "6" 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual !, ♦ Ig i � - Truss: G4 end Warnings before construction commences. building component.Applicability of design parameters and proper GG 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector.Additional permanent bracing of 2'o.c.and at 10'o.c.respectively unless braced throughout their length by continuous sheathing such as plywood sheathing(TC)and/or drywatl(BC). ,,„.+ NOW.. DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ �t 4.No load should be applied to any component until atter all bracing and 4.Installation of truss is the responsibility of the respective contractor. -3y, "%OREGON Ix i.- SEQ. : 5992814 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 1p V 4111 : design loads be applied to any component. and are for"dry condition"of use. ,/� 0 TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the e.Design assumes full bearing at all supports shown.Shim or wedge if v 14, fabrication,handling,shipment and installation of components. necessary. 7.Design assumes adequate drainage is provided. 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center R(`" 111111111111111111TPIMIrCA in BCSI,copies of which will be furnished upon request. it coincideictwith jointcenterche. 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 111 11 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 5'- 1.5" 'COND. 2: Design checked for nett-5 psfl uplift at 24 "oc soacing.I TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 DESIGN ASSUMES MOISTURE CONTENT DOES BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. NOT EXCEED 19%AT TIME OF MANUFACTURE. TC LATERAL SUPPORT <= 12"OC. UON. LOADING Design conforms to main windforce-resisting BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7,0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF system and components and cladding criteria. Connector plate prefix designators: TOTAL LOAD = 42.0 PSFCWind: 140 mph, h=15ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, M M2OHS,I18 S (16 =nMiTekprefix) = CompuTrus, Inc (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), M,M20HS,M16HS,M16 = MT series LL = 25 PSF Ground Snow (Pg) load duration factor=1.6, LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL Truss designed for wind loads REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. in the plane of the truss only. BOTTOM CHORD CHECKED FOR 1OPSF LIVE LOAD, TOP Gable end truss on continuous bearing wall UON. AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY.AND to equal typical et stud verticals. Refer to CompuTrus gable end detail for complete specifications. 12 2 —/ 4.00 ii lig ' I T 0 111A111111111 it, O N O � O 3 M-3x4 J., 5-01-08 ' I _ ��} P R OFFS JOB NAME : POLYGON PLAN 5-B NH G5 Scale: 0.6258 `� GIN�'3Lc^�,C std WARNINGS: GENERAL NOTES,unless otherwise noted: {{',�.J" �/, ! )_-P - �± 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual Q. s ,P lO rfriiE r Truss: G5 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+. incorporation of component is the responsibility of the building designer. �+ 3.Additional temporary bracing to Insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at •+' DES. BY: BS is the responsibility of the erector.Additionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length bydrAwir P Y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC), „A.m., DATE: 7/11/2014 the overall structure Is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 111 JCt�� 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -� ,{.OREGON ^<J SEQ. : 5992815 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 4--../0"+7 \te /r„ design loads be applied to any component, and are for"dry cont%ion”of use. "�}•' �d �^#•- TRAN S I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if4 fabrication,handling,shipment and installation of components. necessary. /��•. V P Po 7.Design assumes adequate drainage is provided. SS{�R 0 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center IIII VIII II II II II III IIII VIII I II IIII TPIM?CA in BCSI,copies of which will be furnished upon request. git coincide with jointanr lines. 9.Digits indicate size of plate in inches. C MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-Z 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 19'- 10.9" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF k1&BTR LOAD DURATION INCREASE = 1.15 1.2=( 0) 50 2.8=(0) 0 BC: 2x4 KDDF M1&BTR SPACED 24.0" O.C. 2-3=(-366) 181 3.4=(-259) 116 IC LATERAL SUPPORT <= 12"OC. UON. LOADING 4-5=(-189) 85 BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5.6=(-105) 55 DL ON BOTTOM CHORD = 10.0 PSF 6-7=( -42) 19 OVERHANGS: 12.0" 0.0" TOTAL LOAD = 42.0 PSF Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) BEARING MAX VERT MAX HORZ BRG REQUIRED BAG AREA C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 0'- 0.0" -23/ 377V -78/ 340H 5.50" 0.60 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 5'- 9.2" 0/ 67V 0/ OH 5.50" 0.11 KDDF ( 625) 5'- 11.2" -169/ 346V 0/ OH 1.50" 0.44 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 9'- 11.2" -118/ 231V 0/ OH 1.50" 0.30 KDDF ( 625) AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. 13'- 11.2" -134/ 272V 0/ OH 1.50" 0.35 KDDF ( 625) 17'- 11.2" -107/ 214V 0/ OH 1.50" 0.27 KDDF ( 625) 19'- 10.9" -16/ 33V 0/ OH 1.50" 0.05 KDDF ( 625) [COND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.' 7-09 12 12-01-03 VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.002" @ -1'- 0.0" Allowed = 0.100" MAX TL CREEP DEFL = -0.003" @ -1'- 0.0" Allowed = 0.133" MAX TC PANEL LL DEFL = -0.031" lb:lice-I .9" Allowed = 0.397" $ MAX TC PANEL TL DEFL = -0.051" .9" Allowed = 0.596" 6 MAX HOAIZ, LL DEFL @ 19'- 10.2"MAX HOAIZ. TL DEFL @ 19'- 10,2"DESIGNSISTURE CONTENT DOES NOT EXETIME OF MANUFACTURE, 12 5 Design conforms to orce-resisting 6.001/ // system and components and cladding criteria. Wind: 140 mph, h=24.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 01"11111/11/1 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), O load duration factor=l.6, 4 4- C,1 Truss designed for wind loads in the plane of the truss only. M-3x6(S) 0 r 3 coii O 1.11°1 V 1 mdMINIMMEMMEMMEMOMMIIMMEMEM 0illigg 8�� -/ O M-3x4 > 1, 1, > 0-10 6-00 13-10-15 IPROVJDE_EULL_BFARING;Jts:2,8,3,4,5,6,71 JOB NAME : POLYGON PLAN 5-6 NH - J10 Scale: 0.2814 `�4\ �� o :.9A� WARNINGS: GENERAL NOTES,unless otherwise noted: "Y 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual X44/ l'.4.41041,11 E "1,",. Truss: J 1 0 and Warnings before construction commences. building component.Applicability of design parameters and proper1 2.2x4 compression web bracing must be installed where shown+, Incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector.Additional 2'o.c.and at 10'o.c.respectively unless braced throughout their length by r��. p ty permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). rear„ .000 DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ yi' �!Ct 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -Sy OREGON `0 SEQ. : 5992816fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used In a non-corrosive environment, /- v' ( hA A. TRANS I D: 403334 design loads be applied to any component. and are for"dry condition"of use. 6 / 2,Q 1.. 5.CompuTrus has no control over and assumes no responsibility for the .Design assumes full bearing at all supports shown.Shim or wedge if 14 fabrication,handling,shipment and installation of components. necessary. / t-� 1 T 7.Design assumes adequate drainage is provided. "r----PRO' �-' 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII VIII VIII II II VIII VIII VIII III IIII TPIMRCA in BCSI,copies of which will be furnished upon request. lines coincide with jointacenter lines. 9. Digits Indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPI RES:12/31/2015 I 1E110111 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 17'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF N1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2.7=(0) 0 BC: 2x4 KDDF k1&BTR SPACED 24.0" O.C. 2.3=(-327) 162 3.4=(-220) 97 TC LATERAL SUPPORT <= 12"OC. UON. LOADING 4.5=(-154) 70 BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5-6=( -69) 32 DL ON BOTTOM CHORD = 10.0 PSF OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BAG AREA Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 0'- 0.0" -23/ 352V -69/ 301H 5.50" 0.56 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 9.2" 0/ 67V 0/ OH 5.50" 0.11 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 5'- 11.2" -168/ 347V 0/ OH 1.50" 0.44 KDDF ( 625) 9'- 11.2" -113/ 224V 0/ OH 1.50" 0.29 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 13'- 11.2" -144/ 295V 0/ OH 1.50" 0.38 KDDF ( 625) AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. 17'- 11.7" -51/ 104V 0/ OH 1.50" 0.17 KDDF ( 625) ICOND. 2: Design checked for net(-5 osfl uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001° @ 0'--10.0" Allowed = 0.083" 7-09-12 10-01-15 MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX TC PANEL LL DEFL = 0.030" @ 3'- 7.4" Allowed = 0.397" -/ MAX TC PANEL TL DEFL = -0.051" @ 2'- 11.9" Allowed = 0.596" MAX HORIZ. LL DEFL = -0.005" @ 17'- 10.9" MAX HORIZ. TL DEFL = -0.005" @ 17'- 10.9" DESIGN ASSUMES MOISTURE CONTENT DOES 5 NOT EXCEED 19% AT TIME OF MANUFACTURE. 12 �t Design conforms to main windforce-resisting ! system and components and cladding criteria. 6.00 I/ Wind: 140 mph, h=23.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 4 load duration factor=l.6, Truss designed for wind loads co in the plane of the truss only. i M 3jc6(S) 1' c On hi M 0 o 1 9 7�I -/ 0 M-3x4 1, I I 0-10 6-00 11-11-11 'PROVIDE FULL BEARING;Jts:2,7,3,4,5.6' Opp JOB NAME : POLYGON PLAN 5-B NH - J9 Scale: 0.3077 �c,' ��(,1N 19 WARNINGS: ' GENERAL NOTES,unless otherwise noted: c ,,.q;y I c' Y I 1.Builder and erection contractor shduld be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual I,r ♦ p+ll 4. 1-" Truss: J 9 and Warnings before construction bommences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be Installed where shown+, incorporation of component is the responsibility of the building designer. -,r • 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at .r DES. BY: BS is the responsibility of the erector.Additional permanent bracing of 2'o.c.and at 10'o.c.respectively unless braced throughout their length by continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). � DATE: 7/11/2014 the overall structure is the respon3bility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ (,;- 4. No load should be applied to any domponenl until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. ,q_OREGON 4, SEQ. : 5992817 fasteners are complete and at no tkne should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, L. "+/ A• h design loads be applied to any component and are for"dry condbion"of use. /60 ''�}+ rQ TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if14„ fabrication,handling,shipment and Installation of components. necessary. / -Fi R I L- 7.Design assumes adequate drainage is provided. 8.This design Is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 111113111111111111 TPI/WTCA in BCSI,copies of which will be furnished upon request. git coincide tae with jointacenter lines. 9.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTruo Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MITek) EXP(RES:12/31/2015 11111EIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 15'- 11.7' IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2.7=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2.3=(-287) 142 3.4=(-184) 79 TC LATERAL SUPPORT <= 12"OC. UON. LOADING 4-5=(-108) 58 BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5-6=( -44) 20 DL ON BOTTOM CHORD = 10.0 PSF OVERHANGS: 10.0" 0,0" TOTAL LOAD = 42.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BAG AREA Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 0'- 0.0" -23/ 353V -61/ 265H 5.50" 0.56 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 9.2" 0/ 67V 0/ OH 5.50" 0.11 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 5'- 11.2" -162/ 343V 0/ OH 1.50" 0.44 KDDF ( 625) 9'- 11.2" -119/ 239V 0/ OH 1.50" 0.31 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 13'- 11.2" -108/ 226V 0/ OH 1.50" 0.29 KDDF ( 625) AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. 15'- 11.7" -15/ 32V 0/ OH 1.50" 0.05 KDDF ( 625) 'COND. 2: Design checked for net(-5 psfl uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10,0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" 6 MAX TC PANEL LL DEFL = 0.031" @ 3'- 7.4" Allowed = 0.397" MAX TC PANEL TL DEFL = -0.051" @ 2'- 11.9" Allowed = 0.596" ;l MAX HORIZ. LL DEFL = -0.004" @ 15'- 10.9" 5 MAX HORIZ. TL DEFL = -0.004" @ 15'- 10.9" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. 12 Design conforms to main windforce-resisting 6.00/ system and components and cladding criteria. 4 Wind: 140 mph, h=23.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, Truss designed for wind loads v in the plane of the truss only. 0 co 3 co O V 1ifidimimiiiim O = 7_� --/ O M-3x4 ,k ) y 1, 0-10 6-00 9-11-11 'PROVIDE FULL BFARING;Jts:2,7,3,4,5,61 JOB NAME : POLYGON PLAN 5-B NH - J83pale: 0.3315 ~ pe 4 ° s, WARNINGS: GENERAL NOTES,unless otherwise noted: 5? //)/ J8 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual ti OP,' ?S•`j!' E 1r' Truss: J 8 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown+. Incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by • is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ±!. ir DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ tr l(�Z"� 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -�y OREGON ^<l SEQ. : 5992818 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, G., �. s,C. design loads be applied to any component. and are for"dry condemn"of use. "'�1` ;�(} 'S' TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if v 14n , �� fabrication,handling,shipment and Installation of components. ecessary. 7.Designlaesassumes atedadequate drainage is sed. P ,�\,. 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 1111111111111111 TPINYfCA in BCSI,copies of which will be furnished upon request. git coincide with jointanr lines. 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 11 VIII(( This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 13'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF k1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2.6=(0) 0 BC: 2x4 KDDF B1&BTR SPACED 24.0" O.C. 2.3=(-246) 122 3.4=(-148) 61 TC LATERAL SUPPORT <= 12"0C. UON. LOADING - 4-5=( -67) 31 BC LATERAL SUPPORT <= 12"0C. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA LOCATIONS REACTIONS REACTIONS SIZE SO.IN. (SPECIES) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 0'- 0.0" -24/ 353V -53/ 231H 5.50' 0.57 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 5'- 9.2° 0/ 67V 0/ OH 5.50" 0.11 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 11.2" -155/ 338V 0/ OH 1.50" 0.43 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 9'- 11.2" -129/ 265V 0/ OH 1.50" 0.34 KDDF ( 625) 13'- 11.7" -51/ 109V 0/ OH 1.50" 0.17 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. ICOND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX TC PANEL LL DEFL = 0.031" @ 3'- 7.4" Allowed = 0.397" 5 -/ MAX TC PANEL TL DEFL = -0.052" @ 2'• 11.9" Allowed = 0.596" 0MAX HORIZ. LL DEFL = -0.003" @ 13'- 10.9" MAX HORIZ. TL DEFL = -0.003" @ 13'• 10.9" I DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. 12 6,001/ 4 Design conforms to main windforce-resisting system and components and cladding criteria. i( Wind: 140 mph, h=22.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, Truss designed for wind loads v in the plane of the truss only. 0 3 0 co o ► - 6 M-3x4 ), y .( y 0-10 6-00 7-11-11 (PROVIDE FULL BEARING;Jts:2.6.3,4 51 JOB NAME : POLYGON PLAN 5-6 NH - I J7 Scale: 0.3795 �e� PN Orr. Aft L/ WARNINGS: 1 GENERAL NOTES,unless otherwise noted: 4.e. / 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 'Ct. 1 `Y{ Si E r Truss: J7 and Warnings before construction ommences. building component.Applicability of design parameters and proper 2.2n4 compression web bra fang my be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary brac ng to inure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector. dditional permanent bracing of 2'o.c.and at 10'o.c.respectively unless braced throughout their length by444,11101 " continuous sheathing such as plywood sheathing(TC)and/ordrywall(BC). "!!. DATE: 7/11/2014 the overall structure is the respon ibility of the building designer. 3.2n Impact bridging or lateral bracing required where shown++ { �+{I. 4.No load should be applied to any mponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -Iy OREGON `�! SEQ. : 5992819 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, G, "A 1�� design loads be applied to any component. and are for"dry condition"of use. / r-Q T TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the e.Design assumes full bearing at all supports shown.Shim or wedge if 14, $� fabrication,handling,shipment and Installation of components. necessary. P P 7.Designlaesassumes adequate both drainage is o truss,and This design is furnished subject to the limitations set forth by 8.Plates shall be located on both feces of truss, placed so their center VIII I I VIII(III VIII II I III II III TPIM/rCA in BCSI,copies of which will be furnished upon request. git coincide with joint ain che. 9.Digitssdsize of plate ein Inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1a88(MiTek) EXPIRES:12/31/2015 11111 11 IIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 11'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2-6=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2-3=(-208) 105 3-4=(-102) 46 TC LATERAL SUPPORT <= 12"OC. UON. LOADING 4.5=( -38) 18 BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF OVERHANGS: 10,0" 0.0" TOTAL LOAD = 42.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 0'- 0.0" -23/ 352V -45/ 198H 5.50" 0.56 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 5'- 9.2" 0/ 66V 0/ OH 5.50" 0.11 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 11.2" -159/ 354V 0/ OH 1.50" 0.45 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 9'- 11.2" -92/ 187V 0/ OH 1.50" 0.24 KDDF ( 625) 11'- 11.7" -19/ 46V 0/ OH 1.50" 0.07 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. ICOND. 2: Design checked for net(-5 psf) uplift at 24 floc ssacing"1 VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001° @ 0'--10.0" Allowed = 0.111" MAX TC PANEL LL DEFL = -0.030" @ 2'- 11.9" Allowed = 0.397" 5 MAX TC PANEL TL DEFL = -0.050" @ 2'- 11.9" Allowed = 0.596" 0 MAX HORIZ. LL DEFL = -0.002' @ 11'- 10.9" MAX HORIZ. TL DEFL = -0.002" @ 11'- 10.9" 12 4 DESIGN ASSUMES MOISTURE CONTENT DOES 6.001/ NOT EXCEED 19% AT TIME OF MANUFACTURE. I �( Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=22.2ft, TCOL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, 3 v Truss designed for wind loads o in the plane of the truss only. 0 no co O/- a O M-3x4 1, y ), 1, 0-10 6-00 5-11-11 'PROVIDE FULL BEARING:Jts:2.6,3,4,51 JOB NAME : POLYGON PLAN 5-6 NH - J 6Scale: 0.4200 'SV a s, WARNINGS: GENERAL NOTES,unless otherwise noted: �//t1 rte C 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual '� •�'7G 1.i L �1.- Truss: ' Truss: J6 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. .r 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at ✓' DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,++ +r/ae. 'mow DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ Cr 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -7 ,qOREGON to shouldSEQ. : 5992820fasteners are complete and at no time any loads greater than 5.Design assumes trusses are to be used In a non-corrosive environment, 4- '74., ,,, A.TRANS I D: 403334 design loads be applied to any component, and are for"dry condition"of use. Jn it ,2,0 ..,}, 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supportsv s shown.Shim or wedge if 1 c�,P fabrication,handling,shipment and installation of components. necessary. 41 j'�R 11 V 7.Design assumes adequate drainage is provided. -' - 8.This design Is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII VIII'III'III'III VIII VIII'III'III TPI WfCA in BCSI,copies of which will be furnished upon request. Digit coincide with joint tecenter lines. 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 III V'I'II This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 9'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-20( 0) 42 2-5=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2.3=(-170) 99 3.4=( -76) 34 IC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BAG REQUIRED BRG AREA OVERHANGS: 10.0" 0,0" TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ,IN. (SPECIES) 0'- 0.0" -22/ 350V -37/ 166H 5.50" 0.56 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 5'- 9.2" 0/ 66V 0/ OH 5.50" 0.11 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 5'- 11.2" -164/ 368V 0/ OH 1.50" 0.47 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 9'- 11.7" -45/ 90V 0/ OH 1.50" 0.14 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 'COND. 2: Design checked for net(-5 PO) uplift at 24 "oc spacing.' AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX TC PANEL LL DEFL = 0.028' @ 3'- 4.9" Allowed = 0.397° 4 MAX TO PANEL TL DEFL = -0.048" @ 2'- 11.9" Allowed = 0.596" MAX HORIZ, LL DEFL = -0,002" @ 9'- 10,9" 12 �� MAX HORIZ. TL DEFL = -0.002" @ 9'- 10.9" LO 6.001/ DESIGN ASSUMES MOISTURE CONTENT DOES OIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria, 3 Wind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=l.6, Truss designed for wind loads �� o in the plane of the truss only. • co o/- v 0 M-3x4 y 0-10 y 6-Ob y 3-11-11 'PROVIDE FULL BEARING:Jts:2.5.3,4I JOB NAME : POLYGON PLAN 5-B NH - J5 Scale: 0.4887 ` ti`c0 RO _ WARNINGS: ', GENERAL NOTES,unless otherwise noted: //j/ (/// .)- 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual t, !,. pe. fir^ E Truss :J5 and Warnings before construction pommences. building component.Applicability of design parameters and proper 2.204 compression web bracing mus)be Installed where shown+. incorporation of component is the responsibility of the building designer. 3.Additional temporary brac g to inure stability during construction 2.Design assumes the top and bottom chords to be laterally t their at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by � is the responsibility of the recta.Additional permanent bracing of continuous sheathingsuch as '0r F plywood ewhere s and/or drywall(BC). ! ''�� DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ � f„r 4.No load should be applied'to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -yy OREGON Ifj SEQ. : 5992821 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used In a non-corrosive environment, 4„ .t, A. design loads be applied to.any component. and are for"dry condition"of use. / 'Q)r r2Q 4 TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 145 necessary. 44 �R 14. QJ fabrication,handling,shipment and installation of components. 7. necessary. assumes adequate drainage is provided. ,. 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII I I I III''III I III II II III III'III TPIMIrCA in BCSI,copies of which will be furnished upon request. git coincideicwith jointcenter lines. B.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015. 111111III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 7'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF N1&BTR LOAD DURATION INCREASE = 1.15 1.2=( 0) 42 2-5=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2-3=(-126) 92 3-4=( -64) 25 TO LATERAL SUPPORT <= 12"0C. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) 0'- 0.0" -24/ 353V -29/ 135H 5.50" 0.57 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 5'- 9.2" 0/ 67V 0/ OH 5.50" 0.11 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 5'- 11.2" -142/ 337V 0/ OH 1.50" 0.43 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 7'- 11.7" -13/ OV 0/ OH 1.50" 0.00 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP :COND. 2: Design checked for net(-5 psf) uplift at 24 "oC spacing,I AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ O'--10.0" Allowed = 0.083° MAX TL CREEP DEFL = -0.001" @ 0'--10.0 Allowed = 0.111" 12 4 MAX IC PANEL LL DEFL = 0.047" @ 2'- 9.3" Allowed = 0.397" MAX TC PANEL TL DEFL = -0.051" @ 2'- 11.9" Allowed = 0.596" 6.001,-- MAX HORIZ. LL DEFL = -0.001" @ 5'- 11.2" MAX HORIZ. TL DEFL = -0.001" @ 7'- 10.9" 3 DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting �) system and components and cladding criteria. I Wind: 140 mph, h=21.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), o load duration factor=l.6, Truss designed for wind loads v. in the plane of the truss only. CO v rid C•) 1 5►� M-3x4 1, y y ,I,0-10 6-00 .Is r :: 1-11-11 JOB NAME : POLYGON PLAN 5-B NH - J4 Scale: 0.5653 co "° , WARNINGS: GENERAL NOTES,unless otherwise noted f//� .�y 1.Builder and erection contractor should be advised of all General Notes 1.This design Is based only upon the parameters shown and is for an individual (4Lr a hit TZ'S:04.2 E 1- Truss: J4 end Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. ,,r 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathingsuch asplywood sheathing(TC)C and/or d all BC. !. g(r ) ( ) -�"r� DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ et 4. 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -57, OREGON 4,/ SEQ. : 5992822 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, _ .,.' /ti design loads be applied to any component. and are for"dry condemn of use. ///... 2,0 ..� TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge If c! 14, fabrication,handling,shipment end installation of components. necessary. 44 7.Designlaesassumes atedadequate drainage Iso bossed. R RIO- 6. This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII VIII VIII IIII VIII VIII VIII IIII IIII TPINYfCA In BCSI,copies of which will be furnished upon request. git coincideiiwith joint center lines. 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 11111110 111 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 6'- 0.0° IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF N1&BTR LOAD DURATION INCREASE = 1.15 1.2=( 0) 42 2.4=(0) 0 BC: 2x4 KDDF N1&BTR SPACED 24.0" 0.C. 2-3=(-96) 68 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 10,0" 0.0' TOTAL LOAD = 42.0 PSF 0'- 0.0" -49/ 379V -22/ 104H 5.50" 0.61 KDDF ( 625) 5'- 9.2" 0/ 74V 0/ OH 5.50" 0.12 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) .5'- 11.7" -69/ 160V 0/ OH 1.50" 0.26 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. ICOND, 2: Design checked for net(-5 osf) uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX TC PANEL LL DEFL = 0.079" @ 3'- 7.2" Allowed = 0.395" 5-11-11 MAX TC PANEL TL DEFL = -0.092" @ 3'- 4.8" Allowed = 0.593" MAX HORIZ. LL DEFL = -0.001" @ 5'- 10.9° 12 MAX HORIZ. TL DEFL = -0.001" @ 5'- 10.9' 6.00 f/ DESIGN ASSUMES MOISTURE CONTENT DOES 3 -/ NOT EXCEED 19% AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting 1111 system and components and cladding criteria. Wind: 140 mph, h=20.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, Truss designed for wind loads in the plane of the truss only. ..d- c.. c' co o/- v o� 1 --- J 4>< M-3x4 0-10 'PROVIDE FULL BEARIN(I:Jts:4.4,31 6-00 JOB NAME : POLYGON PLAN 5-B NH J3 Scale: 0.5843 �c,4 ,N 4.v• -61, WARNINGS: GENERAL NOTES,unless otherwise noted: � / 1.Builder and erection contractor shHuld be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual ft . i. L h+• E 1'^ Truss: J3 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing mull be installed where shown+. Incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to Inure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c,and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the,erector. dddional permanent bracing of continuous sheathingsuch as plywood sheathing(TC)C and/or tl Pcw her s rywall(BC). .�... DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ * Cr: 4. No load should be applied to any domponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -Sig ORGO� 4! SEQ. : 5992823 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 1, A. design loads be applied to any component. and are for"dry condition"of use. / �,r r Q .J� TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 1 , necessary. 4/40-Fi RIO- 6. fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. : This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center II II VIII III VIII VIII VIII VIII II''III TPI/WfCA in BCSI,copies of which will be furnished upon request. it coincide with jointcenterinches.9. Digits indicate size of plate in inches. q MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIIII' This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 6'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 IC: 2x4 KDDF li1&8TR LOAD DURATION INCREASE = 1.15 1.2=( 0) 42 2-4=(0) 0 BC: 2x4 KDDF N1&BTR SPACED 24.0" O.C. 2-3=(-63) 49 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25,0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ,IN. (SPECIES) OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF 0'- 0.0" -41/ 321V -14/ 73H 5.50" 0.51 KDDF ( 625) Connector plate prefix designators: 3'- 10.9" -99/ 114V 0/ OH 1.50' 0.18 KDDF ( 625) g LL = 25 PSF Ground Snow (Pg) 6'- 0.0" 0/ 57V 0/ OH 5.50° 0.09 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. COND. 2: Design checked for net(-5 9sf) uplift at 24 °oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 1OPSF LIVE LOAD. TOP MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" 3-11-11 MAX LL DEFL = 0.000" @ 0'- 0.0" Allowed = 0.078" T 1/ MAX TC PANEL LL DEFL = 0.012" @ 2'- 2.2" Allowed = 0.246" MAX BC PANEL TL DEFL = -0.034" @ 3'- 1.4" Allowed = 0.333" 12 MAX BC PANEL TL DEFL = -0.004" @ 4'- 1.4" Allowed = 0.333" 6.00 L- MAX HORIZ. LL DEFL = -0.000" @ 3'- 10.9" MAX HORIZ. TL DEFL = -0.000' @ 3'- 10.9" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. 3 -/ Design conforms to main windforce-resisting system and components and cladding criteria. 0 Wind: 140 mph, h=20.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, Truss designed for wind loads v in the plane of the truss only. c N M o f- V 111 c, 1 21110- ..1.11 ►4 M-3x4 y ), y 0-10 'PROVIDE FULL BEARING:Jts:2,3,4I 6-00 JOB NAME : POLYGON PLAN 5-B NH - J2 Scale: 0.6394 ,� Ope `` AGN ,A.9� WARNINGS: GENERAL NOTES,unless otherwise noted: J/ "Y 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 4Z. ♦tj/r e E �.c- T r u s s: J2 and Warnings before construction commences. building component.Applicability of design parameters and proper 'Cl = 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top pandec bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by �y �w is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). .-"-° �. "'"� DATE: 7/11/2014 the overall structure Is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ )tt�, 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. 7 OREGON to SEQ. : 5992824 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, L- 1K A. design loads be applied to any component. and are for"dry condition"of use. / �... ,f.� `1 TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if r �I 14, c�,P fabrication,handling,shipment and installation of components. necessary. 'I V 7.Design assumes adequate drainage is provided. -R R I L\- 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII VIII VIII IIII VIII IIII III IIII IIII TPIMITCA in BCSI,copies of which will be furnished upon request. Digit coincide with joint tecenter lines. 9. Digits indicate size of plate In Inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIII) This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 6'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2.4=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2-3=(-35) 40 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 10.0" 0,0" • I TOTAL LOAD = 42.0 PSF 0'- 0.0" -49/ 263V -7/ 43H 5.50" 0.42 KDDF ( 625) • 1'- 10.9" -108/ 90V 0/ OH 1.50" 0.14 KDDF ( 625) Connector plate prefix designators: • LL = 25 PSF Ground Snow (Pg) 6'- 0.0" 0/ 48V 0/ OH 5.50" 0.08 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. ICOND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.) VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" 1-11-11 AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.001" @ 0'--10,0" Allowed = 0.111" • '( 'I MAX TC PANEL LL DEFL = 0.001" @ 1'- 0.0" Allowed = 0.097" MAX TC PANEL TL DEFL = -0.003" @ 1'- 1.5" Allowed = 0.145" 12 MAX BC PANEL LL DEFL = 0.005" @ 2'- 8.6" Allowed = 0.250" MAX BC PANEL TL DEFL = -0.020" @ 3'- 3.8" Allowed = 0.333" 6.00 L- MAX HORIZ. LL DEFL = -0.000" @ 1'- 10.9" MAX HORIZ. TL DEFL = 0.000" @ 1'- 10.9" I DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting • system and components and cladding criteria. • 3 Wind: 140 mph, h=19.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=l.6, Truss designed for wind loads in the plane of the truss only. Aft' ct 0 CO 0,' Cr _ _ 0 1 X 4 M-3x41 0-10 'PROVIDE FULL BEAIIING:Jts:2,3,41 6-00 JOB NAME : POLYGON PLAN 5-B NH - J1 Scale: 0.7144 ��v'' R QF `'6, WARNINGS: GENERAL NOTES,unless otherwise noted: f1� 17 -""Tr1.Builder and erection contractor Should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual t, s G/G 4, E -c- Truss: uss: J1 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bre ing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at .r.1r. DES. BY: BS is the responsibility of the,erector.Additionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by P Y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). r, DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 1M rt /� 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -� OREGON Zli SEW. : 5992825 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are lube used in a non-corrosive environment, ,,- 4,,m M. +�. design loads be applied to any component. and are for"dry condition"of use. / 'II" 2a �s-.1. TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 14, fabrication,handling,shipment and installation of components. 7.necessary. �A f�.1^- y� Design assumes adequate drainage is provided. 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center II II Hill 11111 IIII II I 11111111 III I IIII TPI/WTCA in SCSI,copies of which will be furnished upon request. git coincideitwith jointcenterche. 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1888(MiTek) EXPI RES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 13'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 IC: 2x4 KDDF 81&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2- 8=( -97) 190 8- 7=( 0) 18 BC: 2x4 KDDF 81&BTR SPACED 24.0" O.C. 2- 3=(-257) 48 7- 9=(-158) 297 7- 3=( 0) 49 WEBS: 2x4 KDDF STAND 3- 4=(-224) 105 3- 9=(-308) 164 TC LATERAL SUPPORT <= 12"OC. UON. LOADING 4. 5=(-153) 67 LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5- 6=( -68) 32 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) M 0'- 0.0" -29/ 351V -53/ 231H 5.50" 0.56 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 2.3" 0/ 127V 0/ OH 5.50" 0.20 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 5'- 10.9" -120/ 259V 0/ OH 1.50" 0.33 KDDF ( 625) 9'- 10.9" -137/ 286V 0/ OH 1.50" 0.37 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 13'- 11.7" -50/ 106V 0/ OH 1.50' 0.17 KDDF ( 625) AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. [COND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.008" @ 2'- 3.8" Allowed = 0,254" 13-11-11 MAX TL CREEP DEFL = -0.015" @ 2'- 3.8" Allowed = 0.339" T f MAX HORIZ. LL DEFL = -0.007" @ 5'- 2.3" -/ MAX HORIZ. TL DEFL = 0.009" @ 5'- 2.3" N DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. 12 Design conforms to main windforce-resisting 6.00 system and components and cladding criteria. Wind: 140 mph, h=22.7ft, TCDL=4,2,BCDL=6.0, ASCE 7-10, ;r (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), m load duration factor=1.6, 0 Truss designed for wind loads a• o in the plane of the truss only. 0 8i 0 M-4x6 y�y CO0 k1-1(4-3x4 �C99 - o m 9 .....••• -1 , f Cl. 0111111.1.7111M-3x4 �o O N O C\I M-3x4 M-1.5x4 N y )' )' > 2-03-12 2-10-08 0-09-12 y y Jr' 0-101 2-05-08 y 11-06-03 y 6-00 7-11-11 (PROVIDE FULL BEARING:Jts:2.9.4.5.61 JOB NAME: POLYGON PLAN 5-B NH - J7C Scale: 0.3025 c�' ��{GF ,� WARNINGS: GENERAL NOTES,unless otherwise noted: ((//`/ 7/� 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual �� S 7G s• E _ r Truss: J7C C and Warnings before construction commences. building component.Applicability of design parameters and proper 77 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. .r 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at ✓ ` DES. BY: BS is the responsibility of the erector.Additional 2'o.c.and at 10'o.c.respectively unless braced throughout their length by p y permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). !x. - I`iP DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 0 CZ. 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -�7 OREGON (4 SEQ. : 5992826 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, L, \� ,t+. design loads be applied to any component. and are for"dry condition"of use. ///��... +1�... 2 h; TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 5.Design assumes full bearing at all supports shown.Shim or wedge if s 1 E fabrication,handling,shipment and installation of components. necessary. ill 7.Design assumes adequate drainage is truss, R R y L 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 111111111111111111 TPIPA rCA in BCSI,copies of which will be furnished upon request. Digit coincide with jointacenter lines. 9. Digits indicate size of plate in inches. rr Cp MiTek USA,Inc./CompuTrus Software+7.6.6(1 L)-E 10.For basic connector plate design values see E5R-1311,ESR-1988(MiTek) EXPIRES:(RES:12131r 01IJ IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 9'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2- 8=(-102) 178 8- 7=( 0) 18 BC: 2x4 KDDF k1&BTR SPACED 24.0" O.C. 2- 3=(-245) 43 7- 9=(-165) 278 7- 3=( 0) 49 WEBS: 2x4 KDDF STAND 3- 4=(-213) 71 3- 9=(-289) 171 LONDIOG 4 (-) 77 TC LATERAL SUPPORT <= 12"OC. UON. 5- 6= 101 LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF ) 0 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF OVERHANGS: 10,0" 24.0" TOTAL LOAD = 42.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BOG AREA LL = 25 PSF Ground Snow (Pg) LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) Connector plate prefix designators: 0'- 0.0" -27/ 356V -39/ 215H 5.50" 0.57 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, IncLIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 2.3" 0/ 122V 0/ OH 5.50" 0.20 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT seriesREQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 5'- 10.9" -136/ 299V 0/ OH 1.50" 0.38 KDDF ( 625) 9'- 11.7" -183/ 405V 0/ OH 1.50" 0.52 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY, ICOND, 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.009" @ 2'- 3.8" Allowed = 0.254" 11-11-11 MAX TL CREEP DEFL = -0.014" @ 2'- 3.8" Allowed = 0.339" MAX LL DEFL = 0.042" @ 11'- 11.7" Allowed = 0.200" ,( '1 MAX TL CREEP DEFL = -0.048" @ 11'- 11.7" Allowed = 0.267" /- -/ MAX HORIZ. LL DEFL = -0.007" @ 5'- 2.3" MAX HORIZ. TL DEFL = 0.009" @ 5'- 2.3" DESIGN ASSUMES MOISTURE CONTENT DOES 12 NOT EXCEED 19%AT TIME OF MANUFACTURE. 6.001/ 0Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=22.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 0 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, Ti- o Truss designed for wind loads co 0 to in the plane of the truss only. M-4x6 M-3x4 �= co o �k 9 ►_� -/ o Ri�IIlm' M-3x4 1 -x4 �� w 8 0 0 M-3x4 1, y y y 2-03-12 2-10-08I 0-09-12 1, /, ), 0-10, 2-05-08 L 9-06-03 y 6-00 5-11-11 (PROVIDE FULL BEARING;Jts:2.9.4,5' JOB NAME : POLYGON PLAN 5-B NH - . J6C Scale: 0.3429 �R 061 OF6- WARNINGS: GENERAL NOTES,unless otherwise noted: {1Jr// -fit 1.Builder and erection contractor sh4ull be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 4t !f9G 4.• E r Truss: J 6C n ry truction k ommences. building component.Applicability of design parameters and proper and Warnings before�ongL 2.20 Additional temporary bracinging mu*be installed where shown+, incorporation of component is the responsibility of the building designer. 2.2x4 compression web bra 2.Design assumes the top and bottom chords to be laterally braced at DES. BY" BS toct r.ure stability during construction 2' and at 10'hin respectively unless braced throughout their length)by . is the responsibility of the'erector. dtlitional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). !� DATE: 7/11/2014 the overall structure is the responOiibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ al LZ' 4. No load should be applied to any domponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. 7� :141.1111:2'° EN r;(y SEQ. : 5992827 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are lobe used in a non-corrosive environment, 4- `h� t- desgnloads be applied to any component. and are for"dry condition"of use. / '� -,}TRANS ID: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if fabrication,handling,shipment and installation of components. necessary. M 0 7.Designlaesassumes atedadequate iface is provided. } RI 1,.,1:- 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of twos,and placed so their center IIIIII VIII IIII VIII IIII IIII I III IIII III TP1 VYfCA in SCSI,copies of which will be furnished upon request. git coincideitwith jointacenter lines. 9.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software+7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 11 IIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 9'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2.7=( -69) 178 7-6=( 0) 18 BC: 2x4 KDDF 0/1&BTR SPACED 24.0" O.C. 2-3=(-245) 43 6.8=(-114) 278 6-3=( 0) 49 WEBS: 2x4 KDDF STAND 3-4=(-153) 71 3-8=(-289) 118 LOADING 4-5=( -70) 32 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+OL( 7.0) ON TOP CHORD = 32.0 PSF BC LATERAL SUPPORT <= 12°OC. UON. DL ON BOTTOM CHORD = 10.0 PSF OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 0'- 0.0" -27/ 347V -37/ 166H 5.50" 0.55 KDDF ( 625) g 5'- 2.3" 0/ 122V 0/ OH 5.50" 0.20 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 10.9" -138/ 301V 0/ OH 1.50" 0.39 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 9'- 11.7" -49/ 103V 0/ OH 1.50° 0.16 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP ICOND. 2: Design checked for net(-5 osf) uplift at 24 "oc spacing.) AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001' @ 0'--10,0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = -0.007" @ 2'- 3,8" Allowed = 0.254" MAX TL CREEP DEFL = -0.014" @ 2'- 3.8" Allowed = 0.339' 9-11-11 MAX HORIZ. LL DEFL = -0,005" @ 5'- 2.3" T f MAX HORIZ. TL DEFL = 0.009" @ 5'- 2.3" /- -v DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. 12 1.1 Design conforms to main windforce-resisting 6.001/ system and components and cladding criteria. Wind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, co Truss designed for wind loads o c h1 0 in the plane of the truss only. ..- in v M-4x6 �D o �� o _ m 8 =� ir� M-3x4 M-1.5x4 -,o M-3x4 M-3x4 ), y ) )• 2-03-12 2-10-08 0-09-12 y ), ), y 0-10 7 2-05-08 7-16-03 y 6-00 3-11-11 'PROVIDE FULL BEARING;Jts:2,8,4,51 JOB NAME : POLYGON PLAN 5-B NH - J5C Scale: 0.3783 .� WARNINGS: GENERAL NOTES,unless otherwise noted: 5 ` 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual (k' =1-* P 0 10 E r Truss: J 5C and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,,.." 1 DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ • Cr "+l 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. 7 A_OREGON t SEQ. : 5992828 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 4+ k. , /- TRANS I D: 403334 design loads be applied to any component and are for"dry condition"of use. 8. / 1r , (} 5.CompuTrus has no control over and assumes no responsibility for the Design assumes full bearing at all supports shown.Shim or wedge if 0 14, Iii,. fabrication,handling,shipment and installation of components. necessary. 7.Design assumes adequate ne hdrainage isprovided.mussed. �R I �,,.... 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 1111111111111111121 TPI/WTCA In BCS',copies of which will be furnished upon request. git coincideictwith jointcenterches 9.Digits indicate size of plate In inches. C* MiTek USA,Inc./CompuTrus Software+7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1888(MiTek) EXPI RES:12/31/2015 IIIIIIIIII III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 6'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2.7=( -84) 228 7.6=( 0) 18 BC: 2x4 KDDF #1&BTR SPACED 24.0" 0.C. 2.3=(-297) 65 6-8=(-138) 358 6-3=( 0) 50 WEBS: 2x4 KDDF STAND 3.4=(-153) 82 3-8=(-372) 143 LOADING 4-5=(-100) 0 TC LATERAL SUPPORT <= 12"00. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BC LATERAL SUPPORT <= 12"0C. UON. DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BAG REQUIRED BAG AREA OVERHANGS: 10.0" 23.7" TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SO.IN. (SPECIES) LL = 25 PSF Ground Snow (Pg) O'- 0.0" -35/ 328V -24/ 151H 5.50" 0.53 KDDF ( 625) Connector plate prefix designators: 5'- 2.3" 0/ 144V 0/ OH 5.50" 0.23 KDDF ( 625) C,CN,C18,0N18 (or no prefix) = CompuTrus, Inc LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 11.7" -182/ 415V 0/ OH 1.50" 0.53 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP [COND. 2: Design checked for net(-5 psfl uplift at 24 "oc spacing.1 AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001° @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = -0.010" @ 2'- 3.8" Allowed = 0.254" MAX TL CREEP DEFL = -0.018" @ 2'- 3.8' Allowed = 0.339" MAX LL DEFL = 0.041' @ 7'- 11.7" Allowed = 0.197" MAX TL CREEP DEFL = -0.047° @ 7'- 11.7" Allowed = 0.263" 7-11-11 T T MAX HORIZ. LL DEFL = 0.007" @ 5'- 2.3" MAX HORIZ. TL DEFL = 0.011" @ 5'- 2.3" 12 DESIGN ASSUMES MOISTURE CONTENT DOES 6.00 L- NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=21.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, o (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, ao 0 Truss designed for wind loads in the plane of the truss only. M-4x6 co �I M-3x4 co o� o 6 g� B �o -/ o, o ! M 31¢4 M 1.5x4 o 0 2 0 7 o M-3x4 y y y 2-03-12 2-10-08 0-09-12 , y ), > 0-10, 2-05-08 5-06-03 1 y 6-00 1-11-11 [PROVIDE FULL BEARING:Jts:2,8.41 R Ore JOB NAME : POLYGON PLAN 5-B NH - J4C Scale: 0.4268 -‹5'to P►N 19, f9 - WARNINGS: GENERAL NOTES,unless otherwise noted: -gg��t "Trus1.Builder and erection contractor$h ukl be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 'Z' s,/§ � +,� E 1.- Truss: s: J 4C and Warnings before construction mmences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing mu be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary brac ng to In ure stability during construction DES. BY: BS2.Design assumes the top and bottom chords to be laterally braced at 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the tltlitional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). �.-. DATE: 7/11/2014 the overall structure Is the respon ibility of the building designer. 3.20 Impact bridging or lateral bracing required where shown++ 1(�,- 4.No load should be applied to any component until after all bracing and 4.Installation of truss Is the responsibility of the respective contractor. -� OREGON ^�,r SEQ. : 5992829 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, [.,- 7 \ A. design loads be applied to any component, and are for"dry condition"of use. TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if O '9v+ 2-° -4 14, cy fabrication,handling,shipment and installation of components. necessary. y+ 7.Design assumes adequate drainage is provided. { �l- 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center I II III MI I I 11111 11 III III TPIMIrCA in BCSI,copies of which will be furnished upon request. git coincide with joint ate in inches.9. Digits indicate size of plate in Inches. cam* MiTek USA,Inc./CompuTrus Software+7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPI RES:1 2/331/2201 5 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 6'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR q BC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2-6=(-135) 228 6.5=( 0) 18 WEBS: 2x4 KDDF STAND SPACED 24.0" O.C. 2.3=(-297) 65 5-7=(-218) 358 5-3=( 0) 50 3-4=( -55) 41 3-7=(-372) 226 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ,IN. (SPECIES) 0'- 0.0" -48/ 365V -22/ 104H 5.50" 0.58 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 5'- 2.3" 0/ 144V 0/ OH 5.50" 0.23 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 5'- 11.7" -48/ 108V 0/ OH 1.50" 0.17 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 'COND. 2: Design checked for net(-5 csf) uplift at 24 "oc spacing.) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.012" @ 2'- 3.8" Allowed = 0.254" MAX TL CREEP DEFL = -0.018" @ 2'- 3.8" Allowed = 0,339" MAX HORIZ. LL DEFL = -0.009" @ 5'- 2.3" 5-11-11 MAX HORIZ. TL DEFL = 0.011" @ 5'- 2.3" T T DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. 12 6.00 Design conforms to main windforce•resisting system and components and cladding criteria. Wind: 140 mph, h=20.7ft, TCDL=4.2,BCDL=6.0, ASCE 7.101 0 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=l.6, Truss designed for wind loads in the plane of the truss only. co 0 c M-4x6 0 Ch N e!- co M-3x4 IMOMMIMMOMMEM ' co �o o� o m M-3x4 M-1.5x4 0 � . C) 200:5010 6 0 M-3x4 J, y y y 2-03-12 2-10-08 0-09-12 ) y y y 0-10 2-05-08 6-00 3-06-08 'PROVIDE FULL BEARING;Jts:2.7.4) JOB NAME : POLYGON PLAN 5-B NH - J3C Scale: 0.4902 ', ' �,IN ss,? WARNINGS: GENERAL NOTES,unless otherwise noted: (,�� /// -T -tom'-7 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual ,7{G(., (,1,11"„ Truss: J3C and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector.Additional permanent bracing of 2'o.c.and at 10'o.c.respectively unless braced throughout their length by continuous sheathing such as plywooding(TCand/or drywall(BC). DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing requiredmeed where shown++ #' 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. OREGON SEQ. : 5992830 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 1x A design loads be applied to any component. and are for"dry Condition"of use. f''. TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if C *1).` 1 4 2� h4 necessary. {�,q fabrication,handling,shipment and installation of components. L+ 7.Design assumes adequate drainage is provided. ALy Rt^�11 6.This design Is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center rl r-1 t{,. VIII VIII VIII VIII VIII VIII I III IIII IIIITPI/WTCA in BCSI,copies of which will be furnished upon request. lines coincidew h joint center lines. indicate Digits ndicatate size of plate in inches. MiTek USA,Inc./CompuTrus Software+7,6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 6'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF q1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2-6=(-46) 123 6-5=( 0) 18 BC: 2x4 KDDF #1&BTR SPACED 24.0" 0.C. 2.3=(-188) 24 5.7=(-76) 191 5-3=( 0) 48 WEBS: 2x4 KDDF STAND 3.4=( -22) 28 3.7=(-198) 79 LOADING TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BC LATERAL SUPPORT <= 12"OC. UON, DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 10.0" 0.0" 0'- 0.0" -48/ 325V -141 73H 5.50" 0.52 KDDF ( 625) LL = 25 PSF Ground Snow (Pg) 3'- 10.9" -84/ 70V 0/ OH 1.50" 0.11 KDDF ( 625) Connector plate prefix designators: 6'- 0.0" 0/ 98V 0/ OH 5.50" 0.16 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL M,M2OHS,M18HS,M16 = MiTek MT series REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. ICOND. 2: Design checked for net(-5 psf) uplift at 24 "oc soacing.l BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.005" @ 2'- 3.8" Allowed = 0.170" MAX TL CREEP DEFL = -0.010" @ 2'- 3.8" Allowed = 0.226" MAX LL DEFL = 0.000" @ 5'- 2.3" Allowed = 0.078" MAX BC PANEL TL DEFL = -0.002" @ 3'- 11.9" Allowed = 0.128" 3-11-11 MAX HORIZ. LL DEFL = -0.004" @ 5'- 2.3" MAX HORIZ. TL DEFL = 0.006" @ 5'- 2.3" 12 DESIGN ASSUMES MOISTURE CONTENT DOES 6.00IV NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. f- Wind: 140 mph, h=20.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, M-4Y6 Truss designed for wind loads o - in the plane of the truss only. v I, o o N 441111111111111111111111111111111111111111 M-3x4 5 o/- it 1 1 7 -/ .:1- - +-1 I i M-3x4 �o M-1"5x4 0 2X N 6 c M-3x4 0 I '�' y I I 2-03-12 2-10-08 0-09-12 I I - I I 0-10 2-05-08 I 6-00 3-06-08 'PROVIDE FULL BEARING;dts:2,4,7I JOB NAME : POLYGON PLAN 5-B NH - J2C Scale: 0,5343 �c, 0 IRNOFr WARNINGS: GENERAL NOTES,unless otherwise noted: �{// I /� 1.Builder and erection contractor stkould be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 4t: ±( "'1®0 E f'~ Truss: J 2C and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing mutt be installed where shown+. incorporation of component is the responsibility of the building designer. 3.Additional temporary bra Ing to.insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY• BS2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of th erector Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). !0-' DATE: 7/11/2014 the overall structure is th respbneibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ • Ct. C/� 4. No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -�s ,q_OREGON 44/ SE Q. : 5992831 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used In a non-corrosive environment, G" "� N. 1A. design loads be applied to any component. and are for"dry condition"of use. / '"�' r�-(} M4*TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if �/ 14T' necessary. 41eR R{L�- fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. B.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 111111111111111 TPI/WTCA in BCSI,copies of which will be furnished upon request. git coincide withzjointcenterche. 9.Digitssoinc ae size of platein inches.li . MiTek USA,InC./COmpuTrus Software+7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 11111 VIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 3'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF k1&BTR LOAD DURATION INCREASE = 1.15 1.2=( 0) 42 2-4=(0) 0 BC: 2x4 KDDF N1&BTR SPACED 24.0" O.C. 2-3=(-68) 30 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BAG REQUIRED BRG AREA DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 10,0" 0.0" TOTAL LOAD = 42.0 PSF 0'- 0.0' -58/ 287V -14/ 73H 5.50" 0.46 KDDF ( 625) 1'- 9.2' -3/ 60V 0/ OH 5.50" 0.10 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 3'- 11.7' -44/ 94V 0/ OH 1.50" 0.15 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. ICOND. 2: Design checked for net(-5 osf) uplift at 24 "oc spacing.) VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX BC PANEL LL DEFL = 0.002" @ 1'- 0.1" Allowed = 0.050" MAX BC PANEL TL DEFL = -0.002" @ 1'- 0.1" Allowed = 0.067" 12 3 -/ MAX HORIZ. LL DEFL = -0.000" @ 3'- 10.9' 6.00I/ MAX HORIZ. TL DEFL = -0.000" @ 3'- 10.9' ' ' NOT IEXCEEDU119%ATES ITIMEOF ECONTENT MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=20.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, v (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), o load duration factor=1.6, N Truss designed for wind loads in the plane of the truss only. M/__ 0 v 111 c, 1 2► 4� -/ M-3x4 y y ), ), 0-10 2-00 1-11-11 (PROVIDE FULL BEARING:Jts:2.4,31 JOB NAME : POLYGON PLAN 5-6 NH - ASJ2 Scale: 0.8541 �t3: N O) PR°F s9 WARNINGS: GENERAL NOTES,unless otherwise noted: 4Y I/+ - 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual ' .t.' + rrtt�"E i-- Truss: ASJ 2 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY BS2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). l,.'°'' .: DATE• 7/11/2014 the overall structure is the responsibility of the building designer. 3.20 Impact bridging or lateral bracing required where shown++ t/' (Z' 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -7 .. j�, SEQ. : 5992832 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, y, '41:*.design loads be applied to any component, and are for"dry condition"of use. ///vv .. �L > TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 14, cyP fabrication,handling,shipment and installation of components. necessary. r. V 7.Design assumes adequate drainage is provided. P R f S-.�' 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII VIII VIII VIII I II III I HI III(III TPIMlTCA in BCSI,copies of which will be furnished upon request. git coincideictwithzjointcenterche. 9.Digits indicate size of plate in inches. MiTek USA,InC./COrnpuTrue Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPI RES:12//31/2015 11IIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 2'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( -3) 42 2.4=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2-3=(-45) 15 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 10.0" 0.0" , TOTAL LOAD = 42.0 PSF 0'- 0.0" -62/ 263V -7/ 43H 5.50" 0.42 KDDF ( 625) 1'- 9.2" -18/ 21V 0/ OH 5.50" 0.03 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 1'- 11.74 -18/ 42V 0/ OH 1.50" 0.07 KDDF ( 625) C,CN,C18,CN1B (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. ICOND. 2: Design checked for net(-5 csfl uplift at 24 "oc smacin_g.I VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR IOPSF LIVE LOAD. TOP MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" 1-11-11 AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" T 1' MAX BC PANEL LL DEFL = 0.001" @ 1'- 0.1" Allowed = 0.050" MAX TC PANEL TL DEFL = -0.001" @ 1'- 2.9" Allowed = 0.145" 12 MAX HORIZ. LL DEFL = -0.000' @ 1'- 10.9" 6.00 I/ MAX HORIZ. TL DEFL = -0.000" @ 1'- 10.9" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=19.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 3 -/ load duration factor=l.6, , oi Truss designed for wind loads in the plane of the truss only. /di ' ..i.oo111.111111 o _.„ o 1 2'"0„,,,,,.=IN 4►-3x4! > y y 0-10 2!00 ' [PROVIDE FULL BEARING:Jts:2.4,31 1 I JOB NAME : POLYGON PLAN 5-B NH - ASJ1 Scale: 0.7139 0 PR Ore- "4 N, d' WARNINGS: GENERAL NOTES,unless otherwise noted: .yx 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 'tLr �P i E f'T Truss ASJ 1 and Warnings before construction commences. building component.Applicability of design parameters and proper • 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom ass ds to be laterally braced et DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathingsuch as plywood sheathing(TC)and/or d all BC. ,�! P cwher rY'�' ( ) .., DATE• 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ , 41019011P (� 4. No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -Sy OREGON 4" SEQ. : 5992833 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 4. >K /C design loads be applied to any component. and are for'dry condition"of use. / " 2,1/ TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if 14, `7y.. fabrication,handling,shipment and installation of components. necessary. Jlq R R I L'•- 7.Design assumes adequate both drainagecistrus,provided. 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 11111111111111111111111111111 TPIMlrCA in BCSi,copies of which will be furnished upon request. git coincide with jointacenter lines. B.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 8, IN I MiTek MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL15-343_UPPER Fax 916/676-1909 POLYGON The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision based on the parameters provided by Pacific Lumber&Truss Co.. Pages or sheets covered by this seal: R45642845 thru R45642860 My license renewal date for the state of Oregon is June 30,2017. Lumber design values are in accordance with ANSUTPI 1 section 6.3 These truss designs rely on lumber values established by others. ,‘AGI qs�° cc 87022P E 9� - cIN'oj, OREGON ct <c// L, `Me \� �o � �a A. HER�Pr EX` 'f :06J30/ October 13,2015 Hernandez,Marcos The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSUTPI 1. Job Truss Truss Type Qty Ply POLYGON R45642845 PL15-343_UPPER F01 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Tue Oct 13 08:51:58 2015 Page 1 ID:j7axn40sHnThIyaUAczwOszX1 UY-8NEyW14gRLFddvIFEhBm14aAVwwQ4nAz2y8K8yTrIV 2-6-0 I I 2-2-9 I I 1-2-0 I I 2-4-11 Scale=1:28.6 1.5x3 II 3x5 = 1.5x3 II 3x4= 1.5x3 II 1.5x3 II 3x5 = 1.5x3 II 1 2 3 4 5 6 7 8 e / \ O N e • Ain 13 12 11 10 `� 3x4= 3x8= 3x4= 3x4 = 3x4= 10-8-1 11-4-9 I 9-11-9 nil, 111-3-1 I 16-4-12 I 9-11-9 0.1$ 0.7-0 5-0-3 0-7-0 0-1-8 Plate Offsets(X,Y)— [10:0-1-8,Edge],[11:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.49 Vert(LL) -0.25 11-12 >783 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.64 Vert(TL) -0.40 11-12 >487 360 BCLL 0.0 Rep Stress Incr YES WB 0.56 Horz(TL) 0.05 9 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:72 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=715/Mechanical,9=715/0-4-4 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2463/0,3-4=-2463/0,4-5=-2532/0,5-6=-2532/0,6-7=-2532/0 BOT CHORD 12-13=0/1520,11-12=0/2805,10-11=0/2532,9-10=0/1515 WEBS 6-10=316/0,2-13=-1640/0,2-12=0/1018,4-12=370/0,4-11=-460/161,7-9=-1636/0,7-10=0/1105 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. PR of> GINE4\ cc if87022PE 9c•- 7 N /N ••$, OREG N fr9,Q) �ti 9O AMBER \\ a0 O • n A- HE# EXPIRES:06/30/2017 October 13,2015 i I a.WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MTek9 connectors.This design is based only upon parameters shown,and is for an individual building component,not �* a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing Malek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642846 PL15-343_UPPER F02 FLOOR 5 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:51:58 2015 Page 1 ID:j7axn4OsHnThlyaUAczwOszXl UY-8NEyW 14gRLFddvlFEhBm 14etVOMQ6mAz2y8KSyTrIV I 1-6-0 1 1-3-4 1 1 0-8-3 1 I 7-3-0 I 1-2-0 1 1 1-0-5 1 2-6-0 Scale=1:27.7 1.5x3 I I 3x4= 1.5x3 11 3x4= 1.5x3 11 3x4= 1.5x3 11 3x4= 1.5x3 I I 1 2 34 4 5 6 7 8 9 10 e e • ea_ a o • o _zr N. N 1, e e ee 0 17 15 14 13 12 11 3x4= 3x6= 4x5= 3x5= 1.5x3 11 3x4 = 3x4= 1 3-0-4 I 15-10-12 1 3-0-4 12-10-8 Plate Offsets(X,Y)— [7:0-1-8,Edge],[12:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.25 Vert(LL) -0.07 13-14 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.29 Vert(TL) -0.10 13-14 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.43 Horz(TL) 0.01 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:74 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 16=1266/0-5-8,17=-335/Mechanical,11=456/Mechanical Max UpIift17=426(LC 4) Max Gray 16=1266(LC 1),17=4(LC 3),11=457(LC 4) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=0/1294,3-4=0/750,4-5=0/750,5-6=1002/0,6-7=-1002/0,7-8=-1099/0, 8-9=-1099/0 BOT CHORD 16-17=-664/0,15-16=-1294/0,14-15=0/331,13-14=0/1099,12-13=0/1099,11-12=0/890 WEBS 3-16=-718/0,2-17=0/798,2-16=882/0,5-14=0/737,5-15=-1177/0,9-11=-960/0, 9-12=0/379,3-15=0/856 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. K:ik„NG EFR s`(2 7 8 • 2PE , Yr y N�A), OREGO ..- �<v 9O FMBER A\ OS A. HERCP EXPIRES:06/30/2017 October 13,2015 e I ®WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not Ix a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642847 PL15-343_UPPER F03 Floor 3 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:51:59 2015 Page 1 ID:j7axn4OsHnThlyaUAczwOszXl UY-dZoKir2iRIT6FnUyoxCQJFdkUvGo9WIJBihhtbyTrlU I 2-6-0 I I 2-5-1 I I 1-2-0 I I 2-4-11 I Scale=1:28.9 1.5x3 I I 3x5 = 1.5x3 H 3x4 = 1.5x3 II 1.5x3 II 3x6= 1.5x3 II 1 2 3 4 5 6 7 B / o e 0.1 e e 1 12 11 10 3x4= 3x8= 3x4= 3x5= 3x4= 10-10-9 11-7-1 I 10-2-1 103)9 111-5-9 I I 16-7-4 I 10-2-1 0-'1-8 0-7-0 5-0-3 0-7-0 0-1-8 Plate Offsets(X,Y)— [10:0-1-8,Edge],[11:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.52 Vert(LL) -0.27 11-12 >739 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.66 Vert(TL) -0.43 11-12 >456 360 BCLL 0.0 Rep Stress Incr YES WB 0.58 Horz(TL) 0.05 9 n/a n/a BCDL 5.0 Code IBC20121TPI2007 (Matrix) Weight:73 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=725/0-4-8,9=725/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-2508/0,3-4=-2508/0,4-5=-2587/0,5-6=2587/0,6-7=-2587/0 BOT CHORD 12-13=0/1543,11-12=0/2877,10-11=0/2587,9-10=0/1538 WEBS 6-10=-324/0,2-13=-1666/0,2-12=0/1041,4-12=-399/0,4-11=-480/168,7-9=-1660/0,7-10=0/1140 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. � GNE- / �\� 6) 0�y kr- 87022PE r -N tN Aj, OREGIN ry5 JY 9O F4llER .\\ �`S A. Heck EXPIRES:06/30/2017 October 13,2015 l I WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. q Design valid for use only with MiTek®connectors.The design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BC51 Building Component Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Cams Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642848 PL15-343_UPPER F04 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Tue Oct 13 08:51:59 2015 Page 1 ID:j7axn4OsHnThIyaUAczwOszX1 UY-dZoKi2iRIT6FnUyoxCQJFdgXvD69VVMJBIhhtbyTrlU I 7-3-0 1 1 1-4-11 I I 1-2-0 II 1-0-9 1 2-6-0 I Scale=1:31.6 1.5x3 II 3x6= 1.5x3 11 3x4= 1.5x3 II 3x4= 1.5x3 11 1.5x3 11 4x5= 1.5x3 11 1 2 3 4 5 6 7 8 9 10 N V- V-/ a\\\! e e \ - fel 0 o e e e 1 15 14 13 12 11 3x4= 3x8 = 3x5= 3x4= 4x4 = 3x4= 14-3-11 1 13-1-11 13-8-111 I 18-1-4 13-1-11 0-7-0 0-7-0 3-9-9 Plate Offsets(X,Y)– [12:0-1-8,Edge],[13:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.77 Vert(LL) -0.33 13-14 >663 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.84 Vert(TL) -0.51 13-14 >419 360 BCLL 0.0 Rep Stress Ina YES WB 0.60 Horz(TL) 0.06 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:81 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 16=791/0-4-4,11=791/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2635/0,3-4=-2635/0,4-5=-3446/0,5-6=-3446/0,6-7=-2477/0,7-8=-2477/0,8-9=-2477/0 BOT CHORD 15-16=0/1550,14-15=0/3254,13-14=0/3130,12-13=0/2477,11-12=0/1721 WEBS 7-13=0/354,8-12=-569/0,2-16=-1700/0,2-15=0/1191,4-15=-679/0,6-14=0/405,9-11=-1858/0,9-12=0/1092, 6-13=-860/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. <<g'Eo PRoFFss mac ONG�NEF) ,O2 870 2PE —7 'o1. is OREGO ti 40 O AMBER 1\ a v. OS A. HE ° EXPIRES:06/30/2017 October 13,2015 t ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. Design valid for use only with MTekv connectors.This design is based only upon parameters shown,and is for an individual building component,not NI, a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing M'Tek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Qualify Criteria,DSS-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642849 PL15-343_UPPER F05 Floor 9 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:00 2015 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-5IMiwB2KC2bztw38MfjfrS9u5JbVuvuTQMRFPI yTrIT I 1-3-0 I 1 1-1-1 II 1-2-0 II 2-4-15 I 2-6-0 I Scale=1:35.4 4x5= 3x4= 3x4 = 3x4 = 3x4= 4x4= 3x6 FP= 3x8=- 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 26 25 24 23 22 21 20 19 18 17 3x4 = 4x6= 3x5= 3x6 FP= 3x5 = 3x5 = 4x6= 3x6 = 3x5= 3x5 SP= 15-7-9 I 14-5-9 15-0-9II I 20-9-8 I 14-5-9 0-7-0 b-7-0 5-1-15 Plate Offsets(X,Y)- [12:0-1-8,Edge],[18:0-1-8,Edgel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.59 Vert(LL) -0.40 21 >624 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.76 Vert(TL) -0.62 21 >402 360 BCLL 0.0 Rep Stress Incr YES WB 0.84 Horz(TL) 0.08 17 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:98 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.OE(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.OE(flat) end verticals. WEBS 2x4 OF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 17=909/0-4-8,26=909/0-2-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2003/0,3-4=-2003/0,4-5=-3413/0,5-6=-3413/0,6-7=4247/0,7-8=4247/0, 8-9=-4495/0,9-10=4495/0,10-11=-4230/0,11-12=4230/0,12-13=-3519/0, 13-14=-3519/0,14-15=-3519/0 BOT CHORD 25-26=0/1077,24-25=0/2776,23-24=0/3897,22-23=0/3897,21-22=0/4436,20-21=0/4401, 19-20=0/3519,18-19=0/3519,17-18=0/1990 WEBS 12-19=-357/0,13-18=426/0,2-26=-1375/0,2-25=0/1183,4-25=-987/0,4-24=0/813, 6-24=-618/0,6-22=0/446,15-17=-2149/0,15-18=0/1659,10-20=-272/35,11-20=-327/0, 12-20=0/1057 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Provide mechanical connection(by others)of truss to bearing plate at jnint(c)2& 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and-fastened to each truss with- 10d(0.t31"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. '`(c��0 FFss �(\� ENG)NEER ,o2 cc 87022PE 9r co- rN 7 �Aj, OREG N (yam <U 9O AMBER \i �O �`s A. Heck EXPIRES:06130/2017 October 13,2015 1 t ®WARNING.Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with Mu ck®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall �p building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing ileke is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPIl Quality Criteria,DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642850 PL15-343_UPPER F06 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:01 2015 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-Zxw57X3yzMjgU4eKwMEuOgiAJi57dZUcfOAoxTyTrIS 1-4-0 I 2-6-0 I 1 1.5x3 I I 2 3x4= 3 1.5x3 I I =-- Scale=1:8.7 III lip ilippylq11.10 r Effil Mar I kl 5 " 4 3x4= 3x4= 9-11 4-1-0 6-1-8 3-11-8 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Udefl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) 0.00 5 "" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.10 Vert(TL) -0.04 4-5 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.05 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:19 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 4-1-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 4=174/Mechanical,5=174/0-2-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)5. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. <c- is.„, PROFFSIS 87022PE <- rN y �Aj, OREG•N tis 4N 9O ‘iii \\ 'O On A. HE¢ P EXPIRES:06/30/2017 October 13,2015 f ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. Design valid for use only with M7ekt connectors.This design is based only upon parameters shown,and is for an individual building component,not �; a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Marek' is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642851 PL15-343_UPPER F07 Floor 5 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:02 2015 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1 UY-18UTKt4akgrh6EDXU317wtFEy6GyMs8mtgwLTwyTrIR 1 1-7-12 1 1 1-8-15 1 1-2-0 ii 1-4-9 1 1-6-0 __- 1 Scale=1:30.1 3x6= 1.5x3 I I 3x4 = 1.5x3 II 3x4 = 1.5x3 I I 3x4 = 1.5x3 II 3x5= 1.5x3 I I 1 2 3x8= 3 4 5 6 7 8 9 10 11 444111111144% N �- lo. e'I �' ® a e N e e oe e 19 f' 17 16 15 14 13 3x4 I I 3x6= 3x8= 3x5= 3x5= 1.5x3 II 3x4 = 3x4= 1 1-10-12 211-14 17-5-4 1-10-12 0-1-8 15-5-0 Plate Offsets(X,Y)– [2:0-3-0,Edge],[8:0-1-8,Edge],[13:0-1-8,Edge],[19:Edge,0-1-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.63 Vert(LL) -0.18 14-15 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.76 Vert(TL) -0.27 14-15 >687 360 BCLL 0.0 Rep Stress Incr NO WB 0.67 Horz(TL) 0.03 12 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:83 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing:17-18,16-17. REACTIONS. (lb/size) 18=1194/0-5-8,12=627/0-2-12 Max Gray 18=1194(LC 1),12=662(LC 4) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 1-2=0/670,2-3=-950/312,3-4=-950/312,4-5=-2192/0,5-6=-2192/0,6-7=2379/0, 7-8=2379/0,8-9=-1741/0,9-10=1741/0 BOT CHORD 17-18=-670/0,16-17=-32/1694,15-16=0/2387,14-15=0/1741,13-14=0/1741, 12-13=0/909 WEBS 9-13=-408/0,2-18=-808/0,1-18=-765/0,8-15=-14/787,7-15=-259/0,6-16=-295/0, 4-16=0/641,4-17=-935/0,10-12=-1092/0,10-13 /1027,2-17=0/1309 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)12. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to — he attached to walls at their outer ends or restrained by other means 4)CAUTION,Do not erect truss backwards. — 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)304 lb down at 0-1-8 on top chord. The design/selection of such connection device(s)is the responsibility of others. _to R SFE 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). ��<C NG](�EFcu, ,O2 LOAD CASE(S) Standard 17 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 $ S 2PE Uniform Loads(plf) j Vert:12-19=-8,1-11=80 Concentrated Loads(Ib) r�. Vert:1=-304(F) 1\ /i 7 -0j, OREGO tis O<Cr 90 �n/BER '\ 0`9 A. Heck EXPIRES:06/30/2017 October 13,2015 4 1 WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not NI., a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,OSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642852 PL15-343_UPPER F08 Floor 7 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Tue Oct 13 08:52:02 2015 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-18UTKt4akgrh6EDXU317wtFLO6PFMzVmtgwLTwyTrIR 2-6-0 10-5-10 I I 1-2-0 { I 1-4-14 Scale:3/4"=1' 1.5x3 II 1.5x3 II 1.5x3 II 1.5x3 II 1 23x4= 3 4 53x4= 6 0 0 N7.--- N ee e e e 3x4= (� 1 9 8 3x4= 3x4= 3x4= I 3-1-2 3-f-10 3-9-10 1 4-4-10 4/61 8-6-8 I 3-1-2 0-1- 0-7-0 0-7-0 0-1- 4-0-6 Plate Offsets(X,Y)— [8:0-1-8,Edge1,[9:0-1-8,Edgel LOADING(psf) SPACING- 1-7-3 CSI. DEFL- in (loc) 1/def1 Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.18 Vert(LL) -0.03 7-8 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.17 Vert(TL) -0.06 7-8 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.19 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC20121TPI2007 (Matrix) Weight:39 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=370/0-2-12,7=370/0-2-8 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-732/0,3-4=-732/0,4-5=-732/0 BOT CHORD 9-10=0/682,8-9=0/732,7-8=0/665 WEBS 2-10=-736/0,2-9=-37/269,5-7=-718/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10,7. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. e. �c\� ANGjN;rFR /OZ9 87022P, v • ' cv -0),OR GON 2: 4/.//\,/ 1.O 'BER r-\ �S A. HECk EXPIRES:06/30/2017 October 13,2015 4 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. Design valid for use only with MTel&connectors.This design is based only upon parameters shown,and is for an individual building component,not �" a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiWekA is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quailly Criteria,DSB-89 and BCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Cams Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642853 PL15-343 UPPER F09 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon • 7.530 s Jul 11 2014 MTek Industries,Inc.Tue Oct 13 08:52:02 2015 Page 1 ID:j7axn4OsHnThIyaUAczwOszX1 UY-18UTKt4akgrh6EDXU3I7wtFL26Q_M?fmtgwLTwyTrIR I 2-6-0 I C)- 6 I I 1-2-0 I I 1-7-2 Scale:1"=1' 11.5x3 II 2 3x4= 31.5x3 I I 4 3x4= 51.5x3 I I J OO N N a e e '`0 1.5x3 II 9 8 7 6 3x4= 3x4= 3x4 = I 3-0-14 31-2-¢ 3-9-6 1 4-4-6 1 6-2-8 3-0-14 0-1- 0-7-0 0-7-0 1-10-2 Plate Offsets(X,Y)— [4:0-1-8,Edge],[8:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) -0.02 8-9 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.12 Vert(TL) -0.03 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(TL) 0.00 6 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:29 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 9=267/0-2-8,6=267/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-362/0,3-4=-362/0 BOT CHORD 8-9=0/423,7-8=0/362,6-7=0/362 WEBS 2-9=-456/0,4-6=-424/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)9. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ��_0 R OFFS Qac;: ANG'N�F9 s'O2� 870 2PE N 04 /,-, y Aj, OREGO ti�O4/ 'Aon SMS ER �,' �S A. HECk EXPIRES:06/30/2017 October 13,2015 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTekt connectors.This design is based only upon parameters shown,and is for an individual building component,not �e a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate the design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MTek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642854 PL15-343_UPPER F10 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co. Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:03 2015 Page 1 ID:j7axn40sHnThiyaUAczwOszX1UY-VK1rYC5CVzzYkOojlnHMT5nQtWc?5LTv6KgvOMyTrIQ I 2-3-0 I 1 1-7-11 I I 1-2-0 1 1 1-4-9 1 1-6-0 1 Scale=1:26.9 1.5x3 II 3x5= 1.5x3 II 3x4= 1.5x3 I I 3x4= 1.5x3 I I 3x5= 1.5x3 II 1 2 3 4 5 6 7 8 9 e 9 N - 00000000000 — / \ v 9 9 `4o .'' -e e 1 Ah. 14 13 12 11 G�YTAj 3x4= 3x6= 3x6= 1.5x3 II 3x4= 304= !I 12-3-11 , I 11-1-11 '1-8-111 1 15-5-4 1 11-1-11 0-7-0 0-7-0 3-1-9 Plate Offsets(X,Y)— [6:0-1-8,Edqe],[11:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.55 Vert(LL) -0.18 12-13 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.71 Vert(TL) -0.28 12-13 >663 360 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(TL) 0.04 10 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:70 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 15=673/0-4-4,10=673/0-2-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2121/0,3-4=-2121/0,4-5=-2434/0,5-6=-2434/0,6-7=-1775/0,7-8=-1775/0 BOT CHORD 14-15=0/1291,13-14=0/2467,12-13=0/1775,11-12=0/1775,10-11=0/925 WEBS 7-11=-417/0,2-15=-1416/0,2-14=0/910,4-14=-380/0,5-13=-274/0,6-13=0/820,8-10=-1112/0,8-11=0/1049 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 74GLNE \� 87022PE �r 7 �Aj, OREG N 4531-/./ 9O FtijgER 1\ �49 A. HE EXPIRES:06/30/2017 October 13,2015 1 1 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing M'Tek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPIl Quality Criteria,DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642855 PL15-343_UPPER F11 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:03 2015 Page 1 ID:j7axn40sHnThIyaUAczwOszX1UY-VK1rYC5CVzzYkOojlnHMT5nVTWIK5Qgv6Kgv0MyTrIQ 1 2-6-0 1 0-5-10 1 1 1-2-0 1 1 1-6-14 1 Scale=1:16.4 1.5x3 11 3x4= 1.5x3 11 1.5x3 11 3x4= 1.5x3 11 1 2 3 4 5 6 e e e o _i_i\ 0 0 N N e e d e 3x4-- 1 9 e 8 3x4= 3x4= 3x4 = 1_ 3-1-2 3-F-10 3-9-10 1 4-4-10 416-12 8-8-8 I 3-1-2 0-1-8 0-7-0 0-7-0 0-1-6 4-2-6 Plate Offsets(X,Y)— [8:0-1-8,Edge],[9:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.20 Vert(LL) -0.03 7-8 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.18 Vert(TL) -0.07 7-8 >999 360 BCLL 0.0 Rep Stress Inc- YES WB 0.20 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:40 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=377/0-2-12,7=377/0-4-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=761/0,3-4=-761/0,4-5=-761/0 BOT CHORD 9-10=0/701,8-9=0/761,7-8=0/682 WEBS 2-10=-757/0,2-9=-28/290,5-7=-737/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. � ...,- PROFFss ''t' ii,87022PE 444 9r N - 4(11 /171-v Aj, OREGO qo 4N lO <cMBER \1 O OS A- HEN' EXPIRES:06/30/2017 October 13,2015 c , WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.1W03/2015 BEFORE USE Design valid for use only with MTel&connectors.This design is based only upon parameters shown,and is for an individual building component,not �4 a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mile'k is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/IPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642856 PL15-343_UPPER F12 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Tue Oct 13 08:52:04 2015 Page 1 ID:j7axn40sHnThlyaUAczwOszXlUY-zWbDIY5rGH5PLYNvbUob?IKcYwzDgoB2L_PSYoyTrIP I 2-6-0I I 2-3-5 1 1 1-2-0 I I 2-4-11 Scale=1:28.7 1.5x3 I I 3x5= 1.5x3 II 3x4 = 1.5x3 I I 1.5x3 I I 3x5= 1.5x3 I I 1 2 3 4 5 6 7 8 N �-/ U I \ e a / \_ N -' e e 1� 12 11 10 M 3x4= 3x8= 3x4= 3x4= 3x4= 10-8-13 11-5-5 I 10-0-5 10-If 13 11-3-131 I 16-5-8 I 10-0-5 0-9 0-7-0 5-0-3 0-7-0 0-1-8 Plate Offsets(X,Y)— [10:0-1-8,Edge],111:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.49 Vert(LL) -0.25 11-12 >770 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.65 Vert(TL) -0.41 11-12 >478 360 BCLL 0.0 Rep Stress Ina YES WB 0.57 Horz(TL) 0.05 9 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:72 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=718/0-1-12,9=718/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2476/0,3-4=2476/0,4-5=-2549/0,5-6=-2549/0,6-7=-2549/0 BOT CHORD 12-13=0/1527,11-12=0/2827,10-11=0/2549,9-10=0/1522 WEBS 6-10=-319/0,2-13=-1648/0,2-12=0/1025,4-12=-379/0,4-11=-466/163,7-9=-1643/0,7-10=0/1116 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)13. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. -c<c• P R O�Fsts 8 • 2PE /9r- -7 -0jO RECO cAA c O4N O MQER1� On A. H ERCP EXPIRES:06/30/2017 October 13,2015 1 H ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. x Design valid for use only with Mitek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPII Qualify Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642857 PL15-343_UPPER F13 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:04 2015 Page 1 ID:j7axn40sHnThIyaUAczwOszX1 UY-zWbDIY5rGH5PLYNvbUob?IKYhww3gnT2L_PSYoyTrIP I 2-3-0 I I 1-4-11 II 1-2-0 I I 1-2-5 I 2-6-0 Scale:3/8"=1' 1.5x3 II 3x6= 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 1.5x3 I I 4x5 = 1.5x3 II 1 2 3 4 5 6 7 8 9 10 o _ o _ a o e 0 cx N e e e e _ fXa7 1� 15 14 13 12 3x4= 3x8 = 3x5= 3x4= 4x4 = 3x4= 14-3-11 I 13-1-11 13-8-111 I 18-3-0 I 13-1-11 0-7-0 0-7-0 3-11-5 Plate Offsets(X,V)- [12:0-1-8,Edge],[13:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/def1 lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.74 Vert(LL) -0.33 13-14 >651 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.85 Vert(TL) -0.53 13-14 >412 360 BCLL 0.0 Rep Stress Incr YES WB 0.61 Horz(TL) 0.06 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:81 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 16=797/0-4-4,11=797/0-2-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2664/0,3-4=-2664/0,4-5=-3503/0,5-6=-3503/0,6-7=2556/0,7-8=-2556/0,8-9=-2556/0 BOT CHORD 15-16=0/1564,14-15=0/3297,13-14=0/3200,12-13=0/2556,11-12=0/1731 WEBS 7-13=0/349,8-12=-534/0,2-16=1715/0,2-15=0/1206,4-15=695/0,6-14=-7/395,9-11=1869/0,9-12=0/1118, 6-13=-853/0 NOTES- 1 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)11. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. L FREO PROF FS �G, �NG[N FR , co • sfO1 ' ' 87022PE r nl y 4i, OREGO cy�OIUv 'AC AMBER ON OS A. He'9, EXPIRES:06/30/2017 October 13,2015 t / ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. Design valid for use only with MTekO connectors.This design is based only upon parameters shown,and is for an individual building component,not �s a truss system.Before use.the building designer must verify the applicability of design parameters and properly incorporate the design into the overall building design.Bracing indicated a to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642858 PL15-343_UPPER F14 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:05 2015 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1 UY-Rj9bzu6T1 bDGzix69CJgYWtoWKMsZI4Cae904EyTrlO I 2-0-0 I I 1-10-1 11 1-2-0 1 1 2-5-3 Scale=1:21.0 1.5x3 I I 3x4= 1.5x3 II 3x4= 1.5x3 I I 1.5x3 I I 1 2 3 4 5 6 3x4= 7 e 0 N e o e o e e 12 11 10 9 8 3x4= 3x5= 3x4= 1.5x3 I I 3x4= 1 8-2-9 I 8-9-9I s 4 s I 12-0-12 I 8-2-9 0-7-0 0-7-0 2-8-3 Plate Offsets(X,Y)- [6:0-1-8,Edge],[10:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.42 Vert(LL) -0.14 10-11 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.49 Vert(TL) -0.21 10-11 >670 360 BCLL 0.0 Rep Stress Incl. YES WB 0.33 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:54 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 12=525/0-2-8,8=525/0-1-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=1397/0,3-4=-1397/0,4-5=-1183/0,5-6=1183/0 BOT CHORD 11-12=0/887,10-11=0/1518,9-10=0/1183,8-9=0/1183 WEBS 2-12=-994/0,2-11=0/571,4-10=-443/3,6-8=-1277/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)12,8. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4N... PRQFFss 4c\3ENGINEER /qt. 87022PE v N -y �Aj, OREG•N 1, Owl 'AC AMBER \\ r OS A. HEY" EXPIRES:06/30/2017 October 13,2015 t WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Mil, Design void for use only with Mrfeke connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate the design into the overall building design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642859 PL15-343_UPPER FG1 FLOOR GIRDER 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:06 2015 Page 1 ID:j7axn4OsHnThIyaUAczwOszX1 UY-vvjzAE75ouL7brWljvg35jP2XjoSIpQLoluZchyTrIN 1-4-12 1-4-0 1 1.5x3 I 2 3x4= 3 1.5x3 I I Scale=1:8.7 (41 K 5 4 3x4= 3x4= 2-11-12 I 2-11-12 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.08 Vert(LL) 0.00 5 "" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.09 Vert(TL) -0.01 4-5 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.07 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:15 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 2-11-12 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 OF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=253/Mechanical,5=249/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. WEBS 2-4=309/0,2-5=-304/0 NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)188 lb down at 1-5-2 on top chord. The design/selection of such connection device(s)is the responsibility of others. 4)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) Vert:4-5=10,1-3=-100 Concentrated Loads(Ib) Vert:2=-188(F) Poo. OF�cS �c;D : „/.0 87022PE 9r' N �N OREG•N ti:3 ti 0 �cM8ER 'V1 �O `S A. Her% EXPIRES:06/30/2017 October 13,2015 1 I ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.The design is based only upon parameters shown,and is for an individual building component,not Lq a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642860 PL15-343_UPPER FG Floor Girder 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:05 2015 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1 UY-Rj9bzu6T1 bDGzix69CJgYWtgOKQEZKsCae904EyTrIO I 1-6.0 I 1-5-10 I I 1-2-0 I I 1-4-14 I 2-6-0 I Scale:314"=1' 1.5x3 I I 1.5x3 I I 1.5x3 I I 1.5x3 I I 1 23x4= 11 3 4 53x4= 6 0 0 o e 7-- 0 'I'e e e e e 3x4 = 10 9 8 �( 3x4= /\ 3x4= 3x4= I 3-2-10 13-9-104-4-10 I I 8-6-8 I 3-2-10 0-7-0 0-7-0 4-1-14 Plate Offsets(X,Y)— [8:0-1-8,Edge],[9:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL- in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.26 Vert(LL) -0.03 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.21 Vert(TL) -0.04 9-10 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.22 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:39 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=497/0-2-12,7=412/0-2-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-11=-926/0,3-11=-926/0,3-4=-926/0,4-5=-926/0 BOT CHORD 9-10=0/669,8-9=0/926,7-8=0/771 WEBS 2-10=-804/0,2-9=0/327,5-7=-833/0,5-8=0/303 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10,7. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. . 4)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)233 lb down at 2-2-0 on top chord. The design/selection of such connection device(s)is the responsibility of others. 5)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform LoadsVert:7(10=-8,1-6=-80 ��Fl`EO PR OFFss Concentrated Loads(Ib) �� �Nr7 NFF,9 SQA Vert:11=169(B) `t" 87022PE v1` yN � fiAj, OR EG N rye Q.// 9O c(",,,,. ER ,fir' ' �`S A. HE?' EXPIRES:06/30/2017 October 13,2015 e 1 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev.10/032015 BEFORE USE. 1L Design valid for use only with Mitek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall (� building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/M11 Qualify Criteria,DSB-89 and BCSI Building Component Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Symbols Numbering System General f ty Notes PLATE LOCATION AND ORIENTATION 1 3/" Center plate on joint unless x,y 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property 4 I (Drawings not to scale) Damage or Personal Injury offsets are indicated. I g J ry r�� Dimensions are in ft-in-sixteenths. ii4k. Apply plates to both sides of truss 1 2 3 1. Additional stability bracing for truss system,e.g. and fully embed teeth. diagonal or X-bracing,is always required. See BCSI. TOP CHORDS 1 „ 2. Truss bracing must be designed by an engineer.For 0'/16 4 wide truss spacing,individual lateral braces themselves 0 may require bracing,or alternative Tor ., bracing should be considered. 11=410rO :(5C) 3. Never,exceed the design loading shown and never Ftack materials on inadequately braced trusses. O 4. 'rovi e copies of this truss design to the building For 4 x 2 orientation,locate C7-8 6-7 F— esig ererection supervisor,property owner and plates 0 'na from outside BOTTOM CHORDS II oftier interested parties. edge of truss. 8 7 6 5 5. ut embers to bear tightly against each other. l 6. lace',plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE Joint and embed fully.Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO Illocations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. *Plate location details available in MiTek 20/20 NUMBERS/LETTERS. software or upon request. 8. Unless otherwise noted,moisture content of lumber shall not exceed 19%at time of fabrication. PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for PLATE SIZE ICC-ES Reports: se with fire retardant,preservative treated,or green lumber. The first dimension is the plate 10. am er is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311,ESR-1352,ESR 1988 spo sibility of truss fabricator.General practice is to to slots.Second dimension is ER-3907,ESR-2362,ESR-1397,ESR-3282 am er for dead load deflection. the length parallel to slots. 11. late ype,size,orientation and location dimensions ndic ted are minimum plating requirements. LATERAL BRACING LOCATION 12. 'limb r used shall be of the species and size,and n all r spects,equal to or better than that / Indicated by symbol shown and/or Trusses are designed for wind loads in the plane of the !specified. by text in the bracing section of the truss unless otherwise shown. 13.Top chords must be sheathed or purlins provided at output. Use T or I bracing spacing indicated on design. if indicated. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs relyon lumber values 14.Bottom chords require lateral bracing at 10 ft.spacing, g or less,if no ceiling is installed,unless otherwise noted. BEARING established by others. %eft„ 15.Connections not shown are the responsibility of others. Indicates location where bearings 16.Do not cut or alter truss member or plate without prior (supports) occur. Icons vary but MI NM reaction section indicates joint ©2012 MiTek®All Rights Reserved approval of an engineer. ® ( number where bearings occur. 17.install and load vertically unless indicated otherwise. l Min size shown is for crushing only. htligi 18.Use of green or treated lumber may pose unacceptable environmental,health or performance risks.Consult with project engineer before use. Industry Standards: ANSI/TPII: National Design Specification for Metal 19.Review all portions of this design(frontback,words Plate Connected Wood Truss Construction. and pctures)before use.Reviewing pictures alone DSB-89: Design Standard for Bracing. Millek"' is not sufficient. BCSI: Building Component Safety Information, 20.Design assumes manufacture in accordance with Guide to Good Practice for Handling, ANSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev. 10/03/2015 i1 1 MiTek° MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL14-90UP Fax916/676-1909 5B The truss drawing(s)referenced below have been prepared by MiTek Industries,Inc.under my direct supervision based on the parameters provided by Pacific Lumber & Truss Co.. Pages or sheets covered by this seal:R41832522 thru R41832537 My license renewal date for the state of Oregon is June 30,2015. Lumber design values are in accordance with ANSUTPI 1 section 6.3 These truss designs rely on lumber values established by others. ‘ko PRoF � v4GtN �c > c:;.• 29 + 2PE t r p -oj OREGON c •' O ' BER �' On A. Her' EXPIRES:06130/2015 April 22,2014 Hernandez,Marcos The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSI/TPI 1. ler MiTek® MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL14-90UP Fax916/676-1909 5B The truss drawing(s)referenced below have been prepared by MiTek Industries,Inc.under my direct supervision based on the parameters provided by Pacific Lumber & Truss Co.. Pages or sheets covered by this seal:R41832522 thru R41832537 My license renewal date for the state of Washington is January 2,2015. Lumber design values are in accordance with ANSUTPI 1 section 6.3 These truss designs rely on lumber values established by others. 0,1I0 4,4 0% di waste s 4 4'GZSTER VNACI April 22,2014 Hernandez,Marcos The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSUTPI 1. Job Truss Truss Type Qty Ply 58 R41832522 PL14-90UP F01 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:21 2014 Page 1 i ID:j7axn4OsHnThlyaUAczwOszXIUYcHTKdJc1YpmObb_IRPgo7B0ohgO7S71HOPDhOfzOQTa 1 2-6-0 1 1 2-2-9 1 1 1-2-0 1 1 2-4-11 1 Scale=1:28.6 1.5x3 11 3x5= 1.5x3 11 3x4= 1.5x3 11 1.5x3 11 3x5 = 1.5x3 II 1 2 3 4 5 6 7 8 _ _ _ O O y O IIIIIIIIIIIIIIIIIIIIIIII ' N 13 12 11 10 3x4= 3x8= 3x4= 3x4 = 3x4= 10-8-1 11-4-9 1 9-11-9 1�t 1rr 1 1113-10-7-0 1 1 16-4-12 9-11-9 0-1-b 5-0-3 0-7-0 0-1-8 Plate Offsets(X,Y): 110:0-1-8,Edgel,111:0-1-8,Edgel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.49 Vert(LL) -0.25 11-12 >783 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.64 Vert(TL) -0.40 11-12 >487 360 BCLL 0.0 Rep Stress Incr YES WB 0.56 Horz(TL) 0.05 9 n/a n/a BCDL 5.0 Code IBC20121TP12007 (Matrix) Weight:72 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 13=715/Mechanical,9=715/0-4-4 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. 010X10 '1_ ' TOP CHORD 2-3=2463/0,3-4=-2463/0,4-5=2532/0,5-6=-2532/0,6-7=-2532/0 BOT CHORD 12-13=0/1520,11-12=0/2805,10-11=0/2532,9-10=0/1515 o o' WASiy, 411, WEBS 6-10=-316/0,2-13=-1640/0,2-12=0/1018,4-12=-370/0,4-11=-460/161,7-9=-1636/0,7-10=0/1105 �� �„ `WO NOTES f4' 71;- 4 �O. 1)Unbalanced floor live loads have been considered for this design. — I N 2)Refer to girder(s)for truss to truss connections. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSUTPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to d 4 be attached to walls at their outer ends or restrained by other means. Q 49639 C� ISTE` LOAD CASE(S) Standard ONAL � „„V PROpe t7.' 'o 2- 87022PE 9>r 'c.-.‘' y 5. SAT OREGO �a <1t� 9O &E:R 1� © O.0 & HE �yP EXPIRES:06/30/2015 April 22,2014 t r iWARNTMS-Verify design parameMrs and READ NOTESON 7 IIS AND I{'aUDED HTTEK REFERENCE PAGE FfJ7-7473 re&1/29/2214 BEFORE USE -�� Design valid for use only with Mira connectors.This design is based only upon parameters shown,and is for an individual building component. IVII Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the k( ' ee_* erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPD Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 ifSautbt..r,-.Pine 15P)lumber is specified,tire design selves axe those effective 06/G1/2013 by MSC Job Truss Truss Type Qty Ply 58 R41832523 PL14-90UP F02 FLOOR 5 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:22 2014 Page 1 ID:j7axn40sHnThIyalJAczwOszX1 UY-4U1 igfdfJ7uFCIZU_7B2fOY183goBcGRF3yEw5zOQTZ 1 1-6-0 1 1-3-4 110-8-3 I I 2-3-0 I 1 1-2-0 I I 1-0-5 I 2-6-0 I Scale=1:27.7 1.5x3 I I 3x4= 1.5x3 II 3x4= 1.5x3 II 3x4= 9.5x3 I I 3x4= 1.5x3 I I 1 2 34 — 4 5 6 7 8 9 10 • 2 0 0 _ a o o • N .2- \ , _ ,,../- – ee a e e 7 _ e 17 15 14 13 12 11 3x4= - 3x6= 4x5 = 3x5= 1.5x3 I I 3x4 = 3x4= I 3-0-4 15-10-12 I 3-0-4 12-10-8 Plate Offsets(X,Y): 17:0-1-8,EdgeL 112:0-1-8,Edgel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.25 Vert(LL) -0.07 13-14 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.29 Vert(TL) -0.10 13-14 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.43 Horz(TL) 0.01 11 n/a n/a BCDL 5.0 Code 1BC2012/TP12007 (Matrix) Weight:74 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size) 16=1266/0-5-8 (min.0-1-8),17=-335/Mechanical,11=456/Mechanical Max Uplift 17=-426(LC 4) Max Gray 16=1266(LC 1),17=4(LC 3),11=457(LC 4) 1ONIo FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. 0$ Qv Rf S/ TOP CHORD 2-3=0/1294,3-4=0/750,4-5=0/750,5-6=-1002/0,6-7=-1002/0,7-8=-1099/0, G / z W0 '+- 8-9=1099/0 �$' Ir ,. BOT CHORD 16-17=-664/0,15-16=-1294/0,14-15=0/331,13-14=0/1099,12-13=0/1099,11-12=0/890 . trx � + N WEBS 3-16=-718/0,2-17=0/798,2-16=-882/0,5-14=0/737,5-15=-1177/0,9-11=-960/0, 9-12=0/379,3-15=0/856 47 NOTES .st+ , 49639 1)Unbalanced floor live loads have been considered for this design. f3 0/ TEg •#' 2)Refer to girder(s)for truss to truss connections. 3)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 426 lb uplift at joint 17. �'.40NAL 4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/I-Pi 1. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened-to-each-truss with 3-10d(0.1-31"X 3")nails-Strongbacks to Wit - be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. - LOAD CASE(S) Standard {cr�`� ��GtN4-R 0 870 2PE / f N y 4j, OREGON rte'�4✓ Os' A, HE �� EXPIRES:06/30/2015 April 22,2014 4 4 ®W41181M-Verify design parameters and READ NOTES ON THIS AND Ifiat/DEDKIM REFEREM' PAGE(477-1473rns 1/25/2314BEJREUSE Design valid for use only with Mitek connectors.The design is based only upon parameters shown,and is for an individual building component. �Q Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the ��+/��� erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPIl Quarrly Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute.781 N.Lee Sheet,Suite 312.Alexandria,VA 22314. Citrus Heights,CA,95610 If Southern Firm(5P}lumber is specified,Um values are Ovate effeEhrr 0641/24:11,3 byALSC Job Truss Truss Type Qty Ply 5B R41832524 PL14-90UP F03 Floor 3 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Lake Oswego,Oregon 7.510 5 Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:23 2014 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-Ygb42?eH4R06gv8gYgiHCc57kT4EwOFaTjinSYzOQTY 2-6-0 I I 2-5-1 1 1 1-2-0 I I 2-4-11 Scale=1:28.9 1.5x3 II 3x5= 1.5x3 II 3x4 = 1.5x3 II 1.5x3 II 3x6= 1.5x3 II 1 2 3 4 5 6 7 8 4114111111144111441141111111t No e / \ \ O •O N e e 1 eih. 12 11 10 3x4= 3x8= 3x4= 3x5= 3x4= 10-10-9 11-7-1 I 10-2-1 1013r9 111-5-9 1 1 16-7-4 j 10-2-1 0-1-8 0-7-0 5-0-3 0-7-0 0-1-8 Plate Offsets(X,Y): 110:0-1-8,Edae1.111:0-1-8,Edgel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.52 Vert(LL) -0.27 11-12 >739 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.66 Vert(TL) -0.43 11-12 >456 360 BCLL 0.0 Rep Stress Incr YES WB 0.58 Horz(TL) 0.05 9 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:73 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 13=725/0-4-8 (min.0-1-8),9=725/0-4-4 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. � 4TTO TOP CHORD 2-3=-2508/0,3-4=-2508/0,4-5=-2587/0,5-6=-2587/0,6-7=-2587/0 ri BOT CHORD 12-13=0/1543,11-12=0/2877,10-11=0/2587,9-10=0/1538 © fl1 VIAS-4-1/ WEBS 6-10=-324/0,2-13=1666/0,2-12=0/1041,4-12=-399/0,4-11=-480/168,7-9=-1660/0,7-10=0/1140 C , fry NOTES = Ot VIN 1)Unbalanced floor live loads have been considered for this design. ',7"-' 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to t of be attached to walls at their outer ends or restrained by other means. Q ii 4, 49639 - LOAD CASE(S) Standard 0 �_ISTE�0 '4/ 1 '1.3`�"ONALv PR Opes 870 2 P f' yus cc% ,cv A� OR EG N rtc' 4/ sER '\\ 9�, 4S4i �� A. N�0 EXPIRES:06/30/2015 April 22,2014 WARNING-Ver:fy design paraaretrs and READ!NOTES ON THIS AND wawa EO f47TEK REFEREPCI PAGE 1477-7471 reit 1/29/2014 B5ORH EE —_ Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillify of the E®,�� m erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding �/I fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 N Soothe-cc Pine(SF)-1:sanlses Fs spec 4fie,the design setses are those effective G&fO2 f20i3 bs,MSC Job Truss Truss Type Qty Ply 5B R41832525 PL14-90UP F04 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:24 2014 Page 1 ID:j7axn4OsHnThIyaUAczwOszX1UY-Os9SFLfvrk8yS3it6YDWIpeEXtNnfT6kiNRL? zOQTX I 2-3-0 I 1 1-4-11 ii 1-2-0 ii 1-0-9 1 2-6-0 1 Scale=1:31.6 1.5x3 II 3x6= 1.5x3 II 3x4= 1.5x3 II 3x4 = 1.5x3 II 1.5x3 II 4x5= 1.5x3 II 1 2 3 4 5 6 7 8 9 10 14414 7 0 0 N 0 o ee etll.°°°°°°°°..- - - 00°. -'N.- • 1. 15 14 13 12 11 3x4= 3x8 = 3x5= 3x4 = 4x4 = 3x4= 14-3-11 I 13-1-11 13-8-111 1 18-1-4 I 13-1-11 0-7-0 0.7-0 3-9-9 Plate Offsets(X,Y): 112:0-1-8,Edgel,113:0-1-8,Edoel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) l/defl lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.77 Vert(LL) -0.33 13-14 >663 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.84 Vert(TL) -0.51 13-14 >419 360 BCLL 0.0 Rep Stress Incr YES WB 0.60 Horz(TL) 0.06 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:81 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 16=791/0-4-4 (min.0-1-8),11=791/Mechanical FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. ot ONIO '{L TOP CHORD 2-3=-2635/0,3-4=-2635/0,4-5=-3446/0,5-6=3446/0,6-7=-2477/0,7-8=-2477/0,8-9=-2477/0 BOT CHORD 15-16=0/1550,14-15=0/3254,13-14=0/3130,12-13=0/2477,11-12=0/1721 ©cj Qv�IASi;.>, WEBS 7-13=0/354,8-12=-569/0,2-16=1700/0,2-15=0/1191,4-15=679/0,6-14=0/405,9-11-1858/0,9-12=0/1092, ( 4' iN, o'er" 6-13=-860/0 `" - -._. NOTES N 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. ''P49639 1 . 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to Cl4, '�` G1S, S '{ be attached to walls at their outer ends or restrained by other means. '6'.4',c, 'S. LOAD CASE(S) Standard Ep PROs coca G(NF ,9 Sp)'9 87022PE f y �Aj, OREGN t2f:::'4<v -�a'C' MgER �1 r~ © ' A. Heck EXPIRES:06/30/2015 April 22,2014 i WARNIh S-Vedfy design yatsme rs and READ NOTES ON THIS AND MIMED PfITEK REFEREM2 PAGE MII-1473 reg.1/2Y,12014 BEFORE USE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. M011 Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the Mitek* erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TP11 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If Seuut_'brarn Pine(SP}7uniher is tgectfied,the design values are those effective 06/51/201.3 fry MSC Job Truss Truss Type Qty Ply 56 R41832526 PL14-90UP F05 Floor 9 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc.Mon Apr 21 15:39:26 2014 Page 1 ID:j7axn40sHnThIyaUAczwOszX1 UY-zFGDgOgAMMOghMsFDzG_gEjdrh4P7Ju1AhwS3tz0QTV 1 13-0 1 1-1-1 II 1-2-0 II 2-415 I 2-6-0 I Scale=1:35.4 4x5= 3x4= 3x4= 3x4= 3x4= 4x4= 3x6 FP= 3x8= 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 a 0 1—'7' 11 0O e - e- 26 25 24 23 22 21 20 19 18 17 3x4 = 4x6= 3x5= 3x6 FP= 3x5 = 3x5 = 4x6= 3x6= 3x5= 3x5 WB= 15-7-9 I 14-5-9 5-0-9 20-98 14-5-9 -7-0 6-7-0 5-1-15 1 Plate Offsets(X,Y): 112:0-1-8,Edge),118:0-1-8,Edgel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.59 Vert(LL) -0.40 21 >624 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.76 Vert(TL) -0.62 21 >402 360 BCLL 0.0 Rep Stress Incr YES WB 0.84 Horz(TL) 0.08 17 n/a n/a BCDL 5.0 Code IBC20121TP12007 (Matrix) Weight:98 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.0E(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 17=909/0-4-8 (min.0-1-8),26=909/0-2-8 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. „ONTo TOP CHORD 2-3=2003/0,3-4=-2003/0,4-5=-3413/0,5-6=3413/0,6-7=-4247/0,7-8=-4247/0, 8-9=4495/0,9-10=-4495/0,10-11=-4230/0,11-12=-4230/0,12-13=-3519/0, tjfA,S �a 13-14=3519/0,14-15=-3519/0 ,� ,0 4 , BOT CHORD 25-26=0/1077,24-25=0/2776,23-24=0/3897,22-23=0/3897,21-22=0/4436,20-21=0/4401, F r .o z. t.a 19-20=0/3519,18-19=0/3519,17-18=0/1990 WEBS 12-19=-357/0,13-18=-426/0,2-26=1375/0,2-25=0/1183,4-25=-987/0,4-24=0/813, `it C`1 6-24=-618/0,6-22=0/446,15-17=-2149/0,15-18=0/1659,10-20=-272/35,11-20=-327/0, 12-20=0/1057 NOTES 1C? 49639 4, 1)Unbalanced floor live loads have been considered for this design. ' XSTCR � 2)All plates are 1.5x3 MT20 unless otherwise indicated. .3 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)26. 4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. •ik0 PR 0pe`� SLOAD CASE(S) Standard �� .AG(NE - ., 870 2PE r y Aj OREG•N c 41 1 1V 4S A. H5ek EXPIRES:06/30/2015 April 22,2014 t a WARNING-Vedfy design parame'lrs and READ AVMS ON THIS AND DOMED MEEK REF€R€filo PAGE M11-1475 set 1/29/3978 WORE USEN Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. ' Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the ■�'�e�- erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regardingj/( fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,058.89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 Pi Saut@5ern Pine ISM-lumber is specified,the design values arc those effective O4/G1/2OS3 by ALS( g Job Truss Truss Type Qty Ply 5B R41832527 PL14-90UP F06 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:26 2014 Page 1 ID:j7axn40sHnThIyaUAczwOszXl UY-zFGDgOgAMMOghMsFDzG_gEjkKhEo7WE1AhwS3tzOQTV 1-4-0 I 2-6-0 I 1 1.5x3 II 2 3x4= 3 1.5x3 I I Scale=1:8.7 1111 II 0 N NM =II /- 5 -/ 4 3x4= 3x4= 91-1-8I 4-1-0 0-1-8 3-11-8 LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) 1/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) 0.00 5 "" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.10 Vert(TL) -0.04 4-5 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.05 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:19 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 4-1-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 4=174/Mechanical,5=174/0-2-8 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. p� NOTES 01ONIO '�" 1)Refer to girder(s)for truss to truss connections. o' o''�WWAS „ "Y 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)5. CJ . 7 G' , 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. ,' ' /r `. d4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to { 1, n be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard •P 4 49639,ro I,` G13TE / `SIONALVG� — i,, ,0 PRO tv,N, G1 NE cS0NJ 2-, 87022P• 1.-- / • 4 CU > tv -7 SAT OR GON ,Zo©ski �0©SBER \\ \-. A. HER EXPI RES:06/30/2015 April 22,2014 t y#ARNING-Vedfydesignpassim rs and READ NOTES ON MIS AND INCLUDED MITER REFERENCE PAGE MII-1473 rex t/29/TA1dBEFORE USE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. �5 Applicability of design parameters and proper incorporation of component a responsibility of building designer-not truss designer.Bracing shown MiTele is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the FYiT ��� erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control storage,delivery,erection and bracing,consult ANSI/TPIl Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 ft Scathe-so Pine(SP}lumber is specified,the design vetoes nun those effective /O1f2O13 by ALSC Job Truss Truss Type Qty Ply 5B R41832528 PL14-90UP F07 Floor 5 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc.Mon Apr 21 15:39:28 2014 Page 1 ID:j7axn4OsHnThlyaUAczw0szX1 UY-veOz5iiQuzeOwgoeLOISvfozjUmsbG8Jd?PY81z0QTT 1 1-7-12 I I 1-8-15 1 1 1-2-0 II 1-4-9 1 1-6-0 1 Scale=1:30.1 3x6= 1.5x3 I I 3x4= 1.5x3 I I 3x4= 1.5x3 I I 3x4 = 1.5x3 II 3x5= 1.5x3 II 1 2 3x8= 3 4 5 6 7 8 9 10 11 e e O N 01 e e o � e ee 19 17 16 15 14 13 3x4 II 3x6= 3x8= 3x5= 3x5= 1.5x3 I I 3x4 = 3x4= 1 1-10-12 2-0-14 17-5-4 1-10-12 0-1-8 15-5-0 1 Plate Offsets(X,Y): f2:0-3-0,Edgel,f8:0-1-8,Edgel,x13:0-1-8,Edgel,f19:Edae,0-1-81 LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.63 Vert(LL) -0.18 14-15 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.76 Vert(TL) -0.27 14-15 >687 360 BCLL 0.0 Rep Stress Incr NO WB 0.67 Horz(TL) 0.03 12 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:83 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing:17-18,16-17. REACTIONS (lb/size) 18=1194/0-5-8 (min.0-1-8),12=627/0-2-12 (min.0-1-8) Max Gray 18=1194(LC 1),12=662(LC 4) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. f(7NZ0 TOP CHORD 1-2=0/670,2-3=-950/312,3-4=-950/312,45=-2192/0,5-6=-2192/0,6-7=2379/0, ©$ C)v WAS 7-8=2379/0,8-9=-1741/0,9-10=1741/0 .rf, I'c BOT CHORD 17-18=-670/0,16-17=-32/1694,15-16=0/2387,14-15=0/1741,13-14=0/1741, '4.' 7-)% .� 'd 12-13=0/909 '� O.. L11 WEBS 9-13=-408/0,2-18=-808/0,1-18=765/0,8-15=-14/787,7-15=259/0,6-16=-295/0, = N 416=0/641,4-17=-935/0,10-12=-1092/0,10-13=0/1027,2-17=0/1309 47 NOTES �9 49639 , 1)Unbalanced floor live loads have been considered for this design. GISTTu 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)12. 4{ 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. "IONALVL 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 311)nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5)CAUTION,Do not erect truss backwards. 6)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)304 lb down at 0-1-8 on top chord. EQ PR OP ups AG I[t) The design/selection of such connection device(s)is the responsibility of others. 7)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). �. i Co [ /0 LOAD CASE(S) Standard 4C— 87022PE '7/4f 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(pip Vert:12-19=-8,1-11=80 Concentrated Loads(Ib) Vert 1=304(F) L'' ' , isOREGO c ' <4, O ' H k - EXPIRES:06/30/2015 April 22,2014 WARNIMS-Veifydesignparameters and READ f/TESONTHIS AND MUDDED f4ITEKREFEREP PAGEPfll-7473sea1/29/20E4 WORE USE �� Design valid for use only with M1ek connectors.This design is based only upon parameters shown,and is for an individual building component. I4 Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek'erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/T911 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 tf Southern PineISPitientiter is spettfiett the design micros ase those effective /Oi/2013 tan ALSO Job Truss Truss Type Qty Ply 58 R41832529 PL14-90UP F08 Floor 7 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc.Mon Apr 21 15:39:28 2014 Page 1 ID:j7axn40sHnThIyaUAczwOszX1 UY-veOz5iiQuzeOwgOeLOlSvfo4nUv9bN VJd?PY81zOQTT I 2-6-0 10-5-10 1 1 1-2-0 I I 1-4-14 I Scale:3/4"=1' 1.5x3 II 1.5x3 I I 1.5x3 I I 1.5x3 I I 1 23x4= 3 4 53x4= 6 0 N N ...--- \"\---"- e e e 3x4= 10 9 8 3/ 3x4 3x4= 3x4 = I 3-1-2 31-1�0 3-9-10 1 4-4-10 416-? 6-6-8 3-1-2 0-1- 0-7-0 0-7-0 0-1- 4-0-6 Plate Offsets(XX): 18:0-1-8,Edoe1,19:0-1-8,Edael LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.18 Vert(LL) -0.03 7-8 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.17 Vert(TL) -0.06 7-8 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.19 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:39 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 10=370/0-2-12 (min.0-1-8),7=370/0-2-8 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. iz,I0NIO fig, TOP CHORD 2-3=-732/0,3-4=-732/0,4-5=-732/0 tom' s r BOT CHORD 9-10=0/682,8-9=0/732,7-8=0/665 o ov T.h + WEBS 2-10=-736/0,2-9=-37/269,5-7=-718/0 () ti,' , *- ti's,4 r.NOTES r f� 1 1)Unbalanced floor live loads have been considered for this design. ` , 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10,7. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. of 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to411? 49639 ' be attached to walls at their outer ends or restrained by other means. q ''OiS'ISR- 4.4/ LOAD CASE(S) Standard 470NAT., L ck0 PRQp co Gs ��GI `E /ply 870 2PE 7 ''t , OREGO 2 QOM '$�0 fi�SER " p9- A. He 04P EXPIRES:06/30/2015 April 22,2014 1 ®WARNTMS-Verify design yarantetersand READ NOTES DNTHIS AND MIMED MITER REFERENCE PAGEI+f11-1473Isu 1/29/20346IFOREUSE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. �R Applicability of design parameters and proper incorporation of component b responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek'erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding iV1 fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/7P11 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 if Sauthecr.Pine(01,)kantriser is sgaexifted,:the design values rre tt:saseeft*ohm:0€f01120&3 bit ikt$E Job Truss Truss Type Qty Ply 5B R41832530 PL14-90UP F09 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:29 2014 Page 1 ID:j7axn4OsHnThtyaUAczwOszX1 UY-NgyL12j2fHmFYgbqv5phStLFYuG7KsvTsf96gCzOQTS I 2-6-0 1 0-5-6 1 1 1-2-0 I I 1-7-2 1 Scale:1"=1' 11.5x3 II 2 3x4 = 31.5x3 I I 4 3x4= 51.5x3 I I ii 1 9 \\_° e_ [1, N N D O 1.5x3 II Y�/�" 9 ‘:1), 8 7 6 3x4= 3x4= 3x4 = I 3-0-14 2-63-9-6 1 4-4-6 I 6-2-8 3-0-14 1- 0-7-0 0-7-0 1-10-2 Plate Offsets(X,Y): 14:0-1-8,Edge),18:0-1-8,Edge) LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) -0.02 8-9 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.12 Vert(TL) -0.03 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(TL) 0.00 6 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:29 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 9=267/0-2-8 (min.0-1-8),6=267/Mechanical FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. o'TOMO N, TOP CHORD 2-3=-362/0, -8=3-40362, © WAS X, BOT CHORD 8-9=0/423,7 8=0/362,6-7=0/362 `� WEBS 2-9=-456/0,4-6=-424/0 q Y, J. • �s `- NOTES rn� . *�. N 1)Unbalanced floor live loads have been considered for this design. — J 2)Refer to girder(s)for truss to truss connections. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)9. cr 4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 'd 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to 49639 be attached to walls at their outer ends or restrained by other means. N• orA LOAD CASE(S) Standard �t�NAL�r rEQoFFss —c;„ ti�GI E,''' Vie'. 'r 870 2PE y1-- (1) cv -p 'oj, ©REG N ci, <t/ 90 13ER ,,� - EXPIRES:06/30/2015 April 22,2014 i A.WARNING-Verify design patninehrsand REM NOES uNTNISAND FM2UOED WIEN REFERENCE 5140EMTI-f473mu1/28/2214BEFOREE/S£ �� Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. IQ Applicability of design parameters and proper incorporation of component B responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the e « erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regardingk fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Qualify Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 it Southern Pine(SPI krm@aa is seer:fired,the design values ase those effective /O1/2o13 by ALS Job Truss Truss Type Qty Ply 5B R41832531 PL14-90UP F10 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:30 2014 Page 1 ID:j7axn4OsHnThIyaUAczwOszX1 UY-rOWjWOjgQau6A_AOSoKw_4uKNIS83Cjc4JufCezOQTR I 2-3-0 1 1 1-7-11 I I 1-2-0 I I 1-49 1 1-6-0 1 Scale=1:26.9 1.5x3 II 3x5= 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 3x5= 1.5x3 II 1 2 3 4 5 6 7 8 9 e o ae o o \ / \ o N N e e - e 1- 14 13 12 11 3x4 = 3x6= 3x6= 1.5x3 11 3x4= 3x4= 12-3-11 I 11-1-11 11-8-111 1 15-5-4 I 11-1-11 0-7-0 0-7-0 3-1-9 Plate Offsets(X,Y): 16:0-1-8,Edael.111:0-1-8,Edgel LOADING(psf) SPACING 1-7-3 CSI DEFL in (lac) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.55 Vert(LL) -0.18 12-13 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.71 Vert(TL) -0.28 12-13 >663 360 BCLL 0.0 Rep Stress lncr YES WB 0.53 Horz(TL) 0.04 10 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:70 lb FT=0%F,0%E LUMBER BRACING 1 TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 1 BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 15=673/0-4-4 (min.0-1-8),10=673/0-2-12 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. 'OHIO TOP CHORD 2-3=-2121/0,3-4=-2121/0,4-5=-2434/0,5-6=-2434/0,6-7=1775/0,7-8=-1775/0 BOT CHORD 14-15=0/1291,13-14=0/2467,12-13=0/1775,11-12=0/1775,10-11=0/925 ©G+ eg WAS WEBS 7-11=-417/0,2-15=-1416/0,2-14=0/910,4-14=-380/0,5-13=-274/0,6-13=0/820,8-10=-1112/0,8-11=0/1049 f} ,�-' 0 .t NOTES 4/ <11:.., ' 04 N 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to "¢ 49639 ] be attached to walls at their outer ends or restrained by other means. Q, '0IS'1TR' 4�� LOAD CASE(S) Standard SIIVAL' � 870 2PE y fi � '3,,, OREGO 2 O� 9A 441$ER 4A vr A. H - ik EXPIRES:06/30/2015 April 22,2014 t _ I WARNING-Verify design pamme5rs and READ AWES ON THIS AIM INEMI UDED IEff REFERENCE 9 PAGE Pt11-1473 rat if 29/2014 REUSE * Design valid for use only with Mick connectors.This design b based only upon parameters shown,and is for an individual building component. � Applicability of design parameters and proper incorporation of component b responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek' erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/1PIt Qualify Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available horn Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If Southern Pine 1SP1 lumber is specified,the design Wahl-el Ile those effective O+6/*E12O11.7 h9 ALSC Job Truss Truss Type Qty Ply 5B R41832532 PL14-90UP F11 Floor 2 1 , Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:30 2014 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1 UY-rOW1WOjgQau6A_AOSoKw_4uPzIbT3Hwc4JufCezOQTR I 2-6-0 1 0-5-10 1 1 1-2-0 I I 1-6-14 1 Scale=1:16.4 1.5x3 I I 3x4= 1.5x3 I I 1.5x3 I I 3x4= 1.5x3 II 1 2 3 4 5 6 0 N � ' ‘ — N e 11:: 9 8e3x4= 3x4= 3x4= 3x4 = I 3-1-2 3-?-10 3-9-10 1 4-4-10 4/6-12 8-8-8 I 3-1-2 0-1- 0-7-0 0-7-0 0-1-8 4-2-6 Plate Offsets(X,Y): 18:0-1-8,Edgel,19:0-1-8,Edgel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.20 Vert(LL) -0.03 7-8 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.18 Vert(TL) -0.07 7-8 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.20 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC20121TP12007 (Matrix) Weight:40 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 10=377/0-2-12 (min.0-1-8),7=377/0-4-8 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. ONIO , TOP CHORD 2-3=-761/0,3-4=-761/0,4-5=-761/0 BOT CHORD 9-10=0/701,8-9=0/761,7-8=0/682 ©o OO'lA5 WEBS 2-10=-757/0,2-9=-28/290,5-7=-737/0 ¢, '~ I 9. NOTES ti � Q 1)Unbalanced floor live loads have been considered for this design. '—,.I 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10. 3)This truss is designed in accordance with the 2012 International BuildingCode section 2306.1 and referenced standard AN I/TPI 1. ` T 9S 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to .d be attached to walls at their outer ends or restrained by other means. c 49639 V'? 4. ' GISTEW LOAD CASE(S) Standard �� ''ONAL •,s- PR 0p ss ,C'n.` E '1 pip 4 87022PE f Nyiv -0›, OREGO r 41 , � �O 0BER \ CS Al, HSC'' P EXPIRES:06/30/2015 April 22,2014 6 a WARNING-Verify design Parametersand READ NOTES ONTIfISAND MIMED WIER REFERENa PAGE f411-14733re&1/28/2014Da-ME USE Design valid for use only with Mitek connectors.This design is based only upon parameters shown,and is for an individual building component. 1117I4 Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the ry,AT�y Bim* erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding [VI [ !i fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 It Sss&ne Pine-$SPt iluz Mbar is specified,she design raters axe there effective 0E103./2010 by ALSO 9 Job Truss Truss Type Qty Ply 5B R41832533 PL14-90UP F12 Floor 6 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39.31 2014 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-JD46jkklBuOzn7IDOWr9XIQW2ipMofRmJzeDk4zOQTQ I 2-6-0 I I 2-3-5 1 1 1-2-0 1 1 2-4-11 I Scale=1:28.7 1.5x3 I I 3x5= 1.5x3 I I 3x4 = 1.5x3 I I 1.5x3 I I 3x5= 1.5x3 I I 1 2 3 4 5 6 7 8 o iii N I- / \ \ O / \ - N e e ' 1 12 11 10 3x4= 3x8 = 3x4= 3x4= 3x4= 10-8-13 11-5-5 I 10-0-5 10-11113 113131 1 16-5-8 I 10-0-5 0-4-8 0-7-0 5-0-3 0-7-0 0-1-8 Plate Offsets(X,Y): 110:0-1-8,Edgel,111:0-1-8,Edoel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.49 Vert(LL) -0.25 11-12 >770 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.65 Vert(TL) -0.41 11-12 >478 360 BCLL 0.0 Rep Stress Incr YES WB 0.57 Horz(TL) 0.05 9 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:72 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 13=718/0-1-12 (min.0-1-8),9=718/0-4-4 (min.0-1-8) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. 'TONIO TOP CHORD 2-3=-2476/0,3-4=-2476/0,4-5=-2549/0,5-6=-2549/0,6-7=-2549/0 BOT CHORD 12-13=0/1527,11-12=0/2827,10-11=0/2549,9-10=0/1522 Of? oo W::S,p WEBS 6-10=319/0,2-13=-1648/0,2-12=0/1025,4-12=-379/0,4-11=-466/163,7-9=-1643/0,7-10=0/1116 gyri,*c7 ig+a `�'1WV(r NOTES 'S' - `=; Qy VI 1)Unbalanced floor live loads have been considered for this design. " —, - 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)13. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to ¢111,...„ 49639 L ' be attached to walls at their outer ends or restrained by other means. !ST � w LOAD CASE(S) Standard OVAL RSO PR0pt. 87022PE x-- / yct> ,Cv N �A2j, OREGON 4i O/ 9O Fj(I ER \4 EXPIRES:06/30/2015 April 22,2014 tI RNT5r Q&9A -Vedfy design paratnehtrs and READ AVMS ON THIS AND INCLUDED MIIEK REFEREIWI PAGE(411.7473 tee//29/201d EEFOREUSE Design valid for use only with MTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown __ is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the IVI�IQi` * erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding 3i fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If Scatters.Piste(SM,hentlxer is seeselftesi,that deign values lue thus*efftsxive 0fff#}1 f20i.3 try*LSC Job Truss Truss Type Qty Ply 5B R41832534 PL14-90UP F13 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:32 2014 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-nPeUx4IxyC8gPHKPaDNO3Vzcx55RX5zvYcNmHWzOQTP I 2-3-0 I 1 1-4-11 ii 1-2-0 I I 1-2-5 I 2-60 I Scale:3/8"=1' 1.5x3 I I 3x6= 1.5x3 I I 3x4= 1.5x3 I I 3x4= 1.5x3 I I 1.5x3 I I 4x5 = 1.5x3 I I 1 2 3 4 5 6 7 8 9 10 • 0 0 la'C' _ e e g' 1 15 14 13 12 Xn 354= 3x8 = 3x5= 3x4= 4x4 = 3x4= 14-3-11 I 13-1-11 13-8-111 1 18-3-0 I 13-1-11 0-7-0 0-7-0 3-11-5 Plate Offsets(X,Y): 112:0-1-8,Edgel,r13:0-1-8,Edael LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.74 Vert(LL) -0.33 13-14 >651 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.85 Vert(TL) -0.53 13-14 >412 360 BCLL 0.0 Rep Stress Incr YES WB 0.61 Horz(TL) 0.06 11 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:81 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 16=797/0-4-4 (min.0-1-8),11=797/0-2-12 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. ,hIr TOP CHORD 2-3=2664/0,3-4=-2664/0,4-5=-3503/0,5-6=3503/0,6-7=-2556/0,7-8=-2556/0,8-9=-2556/0 Y" BOT CHORD 15-16=0/1564,14-15=0/3297,13-14=0/3200,12-13=0/2556,11-12=0/1731 oc' WAST, WEBS 7-13=0/349,8-12=-534/0,2-16=1715/0,2-15=0/1206,4-15=-695/0,6-14=-7/395,9-11=-1869/0,9-12=0/1118, W 6-13=-853/0 r'? 1), Rr`i , NOTES : 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)11. ' 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. ''.* 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to 0 _I,49639 be attached to walls at their outer ends or restrained by other means. t', 0ISTat- LOAD CASE(S) Standard �`iONALV' W111 �C.� A GINEF19 s/��9 `r 87022PE r" iii, fe N NI -p fi'aj, OR EGO 4, <1./ -P k.'4,„BERG'` 44 © A. He EXPIRES:06/30/2015 April 22,2014 t ,. ®WARNING-Verify design yarnotetrs and READ NOTES ON THIS AND MINDED MITEK REFERENCE PAGE f411-7473 mu 1/29/2EI4 BEFORE USE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. NI * Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the ��erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 if Soothe:Pine)SP)Is n hr:s is tpesifled the design settles use ttsmxe elfetsive 04/01/2013 by AL:SC Job Truss Truss Type Qty Ply 5B R41832535 PL14-90UP F14 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc.Mon Apr 21 15:39:33 2014 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1UY-FbBs8QmZjVHh1Rub8xudcjWsmVXEGcZ3nG7JpzzOQTO - 2-0-0 I I 1-10-1 I I 1-2-0 1 1 - - 2-5-3 I Scale=1:21.0 1.5x3 II 3x4= 1.5x3 I I 3x4= 1.5x3 I I 1.5x3 II 1 2 3 4 5 63x4= 7 _ — o -it. ee o 0 �o o e 1 11 10e 9 8K' 3x4= 3x5= 3x4= 1.5x3 II 3x4-- 1 1 8-2-9 1 8-9-9 19-49 I 12-0-12 I 8-2-9 0-7-0 0-7-0 2-8-3 Plate Offsets(XX): 16:0-1-8,Edgel,110:0-1-8,Edael LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.42 Vert(LL) -0.14 10-11 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.49 Vert(TL) -0.21 10-11 >670 360 BCLL 0.0 Rep Stress Incr YES WB 0.33 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight 54 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 12=525/0-2-8 (min.0-1-8),8=525/0-1-12 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. , oNIo 't4 " TOP CHORD 2-3=-1397/0,3-4=-1397/0,4-5=1183/0,5-6=1183/0 BOT CHORD 11-12=0/887,10-11=0/1518,9-10=0/1183,8-9=0/1183 ©43 fld WAS, WEBS 2-12=-994/0,2-11=0!571,4-10=443/3,6-8=-1277/0 } l ( ! . U. NOTES is ( . 'x ril 1)Unbalanced floor live loads have been considered for this design. '- ` 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)12,8. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to 'dam, 49639 .r., be attached to walls at their outer ends or restrained by other means. p " GIST ' 1. LOAD CASE(S) Standard ''Zt7NAL1 \ <�g,Et) R Opp, 8 S 2PE �, f cv tit -/ 1,t p 'oj, OREGO c19 <t/ '� � $ER 11 4Q 4S A. H �,�P EXPIRES:06/30/2015 April 22,2014 c WARNING-Verify design warm htnand READ Mf1TESDNTHIS AND T 3.UDEDMITEffREFERENCEPAGEMdi-7473ref.1/25/20149.EFREUSE Design valid for use only with Mack connectors.This design is based only upon parameters shown,and is for an individual building component. �9 Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the R � �p,* erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding EY[ R fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPIl Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Safe 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If Sauthrea:re pine(SF)sunrises is spesif§ed,:tut design values we those effective /01/201.3 by MSC Job Truss Truss Type Qty Ply 5B R41832536 PL14-90UP FG1 FLOOR GIRDER 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc.Mon Apr 21 15:39:34 2014 Page 1 ID:j7axn4OsHnThIyaUAczwOszXl UY-kolEMlnBUpPYebTohePs8w26nvzq?7vC?wstLPzOQTN 1-4-12 I 1-4-0 1 1.5x3 II 2 3x4 = 3 1.5x3 II Scale=1:8.7 p ry kr 1 5 4 3x4 = 3x4= I 2-11-12 I 2-11-12 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.08 Vert(LL) 0.00 5 ""' 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.09 Vert(TL) -0.01 4-5 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.07 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:15 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 2-11-12 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 4=253/Mechanical,5=249/Mechanical FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. WEBS 2-4=-309/0,2-5=-304/0 0-cONIO N., NOTES () ��VIAS 1)Refer to girder(s)for truss to truss connections. cz, Why ' , 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPi 1. ,r-.,‘"' r Q 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to co (" ,z, I be attached to walls at their outer ends or restrained by other means. -- 4)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)188 lb down at 1-5-2 on top chord. The design/selection of such connection device(s)is the responsibility of others. 1 5)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). "d oP 49639 4, LOAD CASE(S) Standard C�, 'GIST - 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 4'�10N J Uniform Loads(plf) Vert:4-5=10,1-3=-100 Concentrated Loads(Ib) Vert:2=-188(F) (\<c_co PROP4- �� 619 5 GIN -9 �'44, j. 87022PE 9r' yc'Oj OREGO cid <t✓� EXPIRES:06/30/2015 April 22,2014 i r ®WARNING-Verify design parameters and READ IC TES ON THIS AND RIMMED ffITEK REFERENCE PAGE f47I-7473 sec 1/29/2014 BERME USE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. N� Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the « erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 if SoIntl••tam Pine(5P}lu sik er is stratified,tha zitsign values are thane affective 06/D3/213€.3 by At3C Job Truss Truss Type Qty Ply 58 R41832537 PL14-90UP FG Floor Girder 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:33 2014 Page 1 ID:j7axn40sHnThIyaUAczwOszX1UY-FbBs8QmZjVHh1Rub8xudcjWuGVbcGeL3nG7JpzzOQTO 1-6-0 I 1-5-10 I I 1-2-0 I I 1-4-14 I 2-6-0 I Scale:3/4"=1' 1.5x3 II 1.5x3 II 1.5x3 I I 1.5x3 I I 1 23x4= 11 3 4 53x4= 6 e e o v 0 0 ni N - e e dX 9 8 3x4= 1 3x4= 3x4= 3x4= I 3-2-10 1 3-9-10 1 4-4-10 1 8-6-8 I 3-2-10 0-7-0 0-7-0 4-1-14 Plate Offsets(X,Y): 18:0-1-8,Edge1,19:0-1-8,Edgel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) 1/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.26 Vert(LL) -0.03 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.21 Vert(TL) -0.04 9-10 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.22 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC20121 TP12007 (Matrix) Weight:39 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 10=497/0-2-12 (min.0-1-8),7=412/0-2-8 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. 'tONIO TOP CHORD 2-11=-926/0,3-11=-926/0,3-4=-926/0,4-5=-926/0 ro- BOT CHORD 9-10=0/669,8-9=0/926,7-8=0/771 o 0 WAS. u WEBS 2-10=804/0,2-9=0/327,5-7=-833/0,5-8=0/303 CJ �4,' ('"7"` :t NOTES + ,j ,Sr .� ' I, IIS 1)Unbalanced floor live loads have been considered for this design. V- ,I _ N 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10,7. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to 49639oil r ' be attached to walls at their outer ends or restrained by other means. L?; 4,,,,49639,,,,-N - 01STES ' 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)233 lb down at 2-2-0 on top chord. CS The design/selection of such connection device(s)is the responsibility of others. �ONALi 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate lncrease=1T00- _0-.) P R opt— Uniform Loads(p1f) <CItk t.a s Veed Loa=-8,1-6=-80 w(`� .1- 15) /qt. Concentrated Loads(Ib) Vert:11=-169(B) ' 870 2PE f 7SAT ©REG N clic' W O 1. '4l ERI'` �� On A. HARP EXPIRES:06/30/2015 April 22,2014 1 ®WARNING-Vesfy deuign parameters and READ NOTES ON Tk1SAND INN€1u"EO MITER REFERENCE PAGE NII-1473 ret 1/29/204 BE ORE USSE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown Mil is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction's the responsibillity of the MiTek` erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/1911 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 it 5autexw Pine(IP}lumber is apes-lied,the design waitres sre 1laose.effective 05/41/2013 by A&SC Symbols System eral Safety Notes PLATE LOCATION AND ORIENTATION 1 3j" Center plate on joint unless x,y 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property 4 (Drawings not to scale) offsets are indicated. II Damage or Personal Injury WMDimensions are in ft-in-sixteenths. 1.40, Apply plates to both sides of truss 1 2 3 1. Additional stability bracing for truss system,e.g. and fully embed teeth. TOP CHORDS diagonal or X-bracing,is always required. See BCSI. 01 „ 2. Truss bracing must be designed by an engineer.For '/16 4 wide truss spacing,individual lateral braces themselves p may require bracing,or alternative Tor I Millina O ik,11111k>1 p bracing should be considered. O 3. Never exceed the design loading shown and never F � stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building For 4 x 2 orientation,locate .-7 Cs , designer,erection supervisor,property owner and plates 0 "i s' from outside BOTTOM CHORDS all other interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully.Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. Plate location details available in MiTek 20/20 NUMBERS/LETTERS. software or upon request. 8. Unless otherwise noted,moisture content of lumber shall not exceed 19%at time of fabrication. PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for ICC ES Reports: use with fire retardant,preservative treated,or green lumber. The first dimension is the plate 10.Camber is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311,ESR 1352,ESR 1988 responsibility of truss fabricator.General practice is to to slots.Second dimension is ER-3907,ESR 2362,ESR-1397,ESR-3282 camber for dead load deflection. the length parallel to slots. 11.Plate type,size,orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and Southern Pine lumber designations are as follows: in all respects,equal to or better than that i� Indicated by symbol shown and/or SYP represents values as published specified. i by AWC in the 2005/2012 NDS by text in the bracing section of the SP represents ALSC approved/new values 13.Top chords must be sheathed or purlins provided at output. Use T or I bracing with effective date of June 1,2013 spacing indicated on design. if indicated. 14.Bottom chords require lateral bracing at 10 ft.spacing, or less,if no ceiling is installed,unless otherwise noted. BEARING %Is,' 15.Connections not shown are the responsibility of others. Indicates location where bearings 16.Do not cut or alter truss member or plate without prior (supports) occur. Icons vary but ©2012 MiTek®All Rights Reserved approval of an engineer. reaction section indicates joint ® number where bearings occur. 17.Install and load vertically unless indicated otherwise. Min size shown is for crushing only. 11111.111111110MI18.Use of green or treated lumber may pose unacceptable environmental,health or performance risks.Consult with project engineer before use. Industry Standards: ANSI/TPI1: National Design Specification for Metal 19. w all portions of thisuse. r , w Plate Connected Wood Truss Construction. andReviepictures)before Review ng(fontpicturesback,alone ords is not sufficient. design DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, 20.Design assumes manufacture in accordance with Mak* Guide to Good Practice for Handling, M ANSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev.01/29/2013