Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (153)
N\Ec ao\9 sw \c)1\va.. cc‘ . RECEIVED Submittal Data Sheet 2.5 Ton,Cased Horizontal"A",Coil 1 OCT 1 2018 CHPF2430B6 CITY OF'TIGARD RES. BUILDING DIVISION a All-Aluminum evaporator coil a Optimized for use with R-410A refrigerant • Some models suitable for use with R-410A or R-22 refrigerant CAPT models feature factory-installed thermal expansion valves for cooling and heat pump applications • Check flowmtor for cooling and heat pump applications • Vertical and horizontal models available • 21"depth for easier attic access • Split seam front for easy access • Foil-faced insulation covers the internal casing to reduce cabinet x condensation r Galvanized,leather grain-embossed finish • Rust resistant,thermoplastic drain pansfeaturingalowwater-retention design • DecaBDE-free thermoplastic drain pan with secondary drain connections • UV-resistant drain pan CHPF AHRI certified ETL TL listed I` �' �,4B�96W�t•�:,:. .nT4R CEN. C US ISO OW1 • Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data ....._..___..-__._�il�.__v.._'..:..`��1 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:11/29/2017 5:13:41 PM Page 1 of 3 Submittal Data Sheet 2.5 Ton,Cased Horizontal"A",Coil CH PF2430B6 Product Model No. CHPF2430B6 Product Model Name: 2.5 Ton,Cased Horizontal"A",Coil Type Coil Cooling Capacity(Nominal)(Btu/hr): 30,000 0- `•..mss. Dimensions(HxWxD)(in): 17-1/2 x 21-1/8 x 21 Suction Valve Connection Size(inch): 3/4 - Net Weight(Ib): 55 Liquid Valve Connection Size(inch): 3/8 Gross Weight(Ib): 50 Condensate Connection(inch): 3/4 Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:11/29/2017 5:13:41 PM Page 2 of 3 1KIN- ' ' @D\ \\ Submittal Data Sheet 2.5 Ton,Cased Horizontal"A",Coil CH PF2430B6 ID 4 Si \\ BRAWN CABINET DIMENSIONS PLENUM NOMINAL CONNECTION , PISTON SHIP MODEL — WEIGHT D W H D H TONS LIQUID SUCTION SIZE' OS) CHPF1824A6 21/x" 26" 14" 19" I 13" 1%-2 Jig" l" .059 36 CHPF2430B6 21'frz 26" 1.7'J" 19" ' 16'l" 2-2% ye 1" .065 55 CHPF3636B6 21'4" 26" 1734" ? 19" I 166/2" 3 %" f" .074 5O CHPF3642C6 21/x" 26" 71" I 19" 1 20" 3-3% %" f" .076 63 Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:11/29/2017 5:13:41 PM Page 3 of 3 P- , Submittal Data Sheet 800 CFM,Multi-Position,Multi-Speed Modular Blower MBRO800AA-1 STANDARD `U E • Direct drive,multi-speed PSC blower motor S Cooling or heat pump applications:upflow,downflow,and horizontal • Blower section usable as an electric furnace • Control board includes a fan delay in the cooling mode and is isolated from the air stream 0. Intended for use with CAPF/CHPF cased evaporator coils S CAPF/CHPF coils are equipped with a check flowrater 6 AHRI certified ETL listed CABINET FEATURES �. S Painted,galvanized steel cabinet Horizontal or vertical configuration % �y capabilities 21"depth for easier attic access Foil-faced insulation is glued in place and covers the entire blower case to reduce operating sound and cabinet condensation Galvanized,leather grain-embossed finish 3 kW a€" 21 kW electric heat kits available Cabinet air leakage less than 2%at 1.0 inch H2O when tested in accordance with ASHRE standard 193 Cabinet air leakage less than 1.4%at 0.5 inch H20 when tested in accordance with •`, ASHRE standard 193 e,..01a ,�s ��, ear&k. 4 \?, c l6S Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:11/29/2017 5:14:32 PM Page 1 of 3 VDAIKZN Submittal Data Sheet 800 CFM,Multi-Position,Multi-Speed Modular Blower M BR0800AA-1 \ Product Model No. MBR0800AA-1 Product Model Name: 800 CFM,Multi-Position,Multi-Speed Modular Blower Type: Air Handler Cooling Capacity(Nominal)(Btu/hr): Blower Motor Rating(HP): 1/4 Power Supply(V/Hz/Ph). 208-230/60/1 Airflow Rate(High/Low)(CFM): 1200/500 Min.Circuit Amps MCA(A): 1.9 Suction Valve Connection Size(inch): Max Overcurrent Protection(MOP)(A): 15 Liquid Valve Connection Size(inch): Dimensions(HxWxD)(in): 26 x 17-1/2 x 21 Condensate Connection(inch): Net Weight(lb): 62 Blower Size Diameter(inch): 9 Gross Weight(Ib): 62 Blower Size Width(inch): 6 Daikin North America LLC,5151 San Felipe,Suite 500,Houston,TX,77056 Daikin City Generated Submittal Data (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date:11/29/2017 5:14:32 PM Page 2 of 3 GoodmanGSZIA• Air Conditioning&Heating CoouNG CAPACITY:18,000 To 60,000 BTU/H ENERGY-EFFICIENT HEATING CAPACITY::18,000 To 60,000 BTU/H SPLIT SYSTEM HEAT PUMP UP TO 15 SEE 9.0 HSPF 13a TO 5 TONS Contents Nomenclature 2 Product Specifications 3 + 11111/2) Cooling Data 5 Expanded Heating Data 29 Performance Data 32 AHRI Ratings 34 i tYlk"i Wiring Diagram 51 Dimensions 52 F Accessories 52 u� ;IN!'K S F ri Standard Features Cabinet Features • High-efficiency scroll compressor • Goodman brand sound control top design • SmartShift'"technology to • Steel louver coil guard ensure quiet reliable defrost • Heavy-gauge galvanized-steel cabinet • Factory-installed bi-flow liquid-line filter drier • Attractive Architectural Gray powder-paint • Factory-installed suction-line accumulator finish with 500-hour salt-spray approval • Factory-installed compressor crankcase heater • Top and side maintenance access • Factory-installed high-capacity muffler • Service ports and controls are • High-and low-pressure switches accessible while unit is operating • Service valves with sweat connections • When properly anchored, meets the 2010 and easy access to gauge ports Florida Building Code unit integrity • Copper tube/enhanced aluminum fin coil requirements for hurricane-type winds • Fully charged for 15'of tubing length (Anchor bracket kits available.) • Contactor with lug connection • Ground lug connection • AHRI Certified;ETL Listed PARTS.7 � fv�CER11ilED'Pf0 E'f I':ng 3 'n5 :.a-Cr C ^T nT irlt" LIMITED CUS `"'""`' OUALPTY SYSTEM ENNRONMENTAL SYSTEM Proper q v �`° 'are.' CERTIFIED BY DNV GL CERTIFIED BY DNY GI_ "r4"11* Tc ar i g m er rman Splt err air I YEAR maP PANTY' "" =Iso soot Iso+aom Intertek -r cord dc.ers a E pumps ru e r 3Tc d wit" BBB ASK ABOUT ENERGY STAR - appropriate-oi r mp e cst r e ENER Y Sl citeria. Compete war warranty ,a'Isa a bl.F:.,rr y., L,_ dealer,r atww,•rgoodmanr <rr f r,ceive r..,..:_ontrc,or for d. �oa coir o, n_ey,.,Igo¢ e 10-Year Parts.:r ted Aa my online registration must be competed wiz,r EC days cf � instal at en.Online registration�>rio t regi:red in Ca Lfcrnia or O ut er. SS-GSZ14 www.good man mfg.corn 9/17 Supersedes i;.1 NOMENCLATURE 14 036 1 AA 1 2 3 4,5 6,7,8 9 10,11 Brand Engineering* G Goodman"Brand Major&Minor revisions for ir:ventcrycor;rroI. Product Category S Split System Electrical 1-208/230 V,1 Phase,60 Hz Unit Type X Condenser R-410A Nominal Capacity Z Heat Pump R-410A 018-1&tons 042 35 Tons 024-2 tons 046 4 Mrs Efficiency 030-2.!.";tons 060 5 Tons 13 13 SEER 16 16 SEER 036-3 tons 14 14 SEER 18 18 SEER 2 www goodmanmfg corn SS-GSZ14 PRODUCT SPECIFICATIONS GSZ14 G5214 GSZ14 GSZ14 1 GSZ14 1 GSZ14 0131K* 0191A* 0241K* 0251A* 0301K* 03114*_ NOMINAL CAPACITIES Cooling(BTU/h) 18,000 17,400 24,000 23,200 30,000 28,000 Heating(BTU/h) 18,000 18,000 24,000 23,200 30,000 31,000 ' Decibels 72 72 72 72 74 75 COMPRESSOR RLA 9.0 9.0 10.9 10.9 1 13.5 13.5 LRA 47.5 47.5 62.9 62.9 72.5 72.5 Type Scroll Scroll Scroll Scroll Scroll Scroll CONDENSER FAN MOTOR Horsepower 1/6 1/6 1/6 1/6 1/6 1/6 FLA 0.95 1.1 0.95 1.1 0.95 1.10 REFRIGERATION SYSTEM 1 1 I Refrigerant Line Size' Liquid Line Size("O.D.) %" /8" %" %" %" %" Suction Line Size("O.D.) /" %" /" /" 9," Refrigerant Connection Size Liquid Valve Size("O.D.) %" %" %" %" s' fig" Suction Valve Size("O.D.) /" /" /" /" /" /" Standard Line Set Length(max.feet) 80 80 80 80 80 80 Long Line Set Length(max.feet)2 Equivalent Length 250 250 250 250 250 250 Linear Length 200 200 200 200 200 200 Vertical Length(outdoor below indoor) 80 80 80 80 80 80 Vertical Length(outdoor above indoor) 80 200 80 200 80 200 Valve Connection Type Sweat Sweat Sweat Sweat Sweat Sweat Refrigerant Charge(oz.) 92 92 92 92 95 160 ELECTRICAL DATA Volts/Phase(60 Hz) 208-230/1 l 208-230/1 208-230/1 208-230/1 208-230/1 208-230/1 Minimum Circuit Ampacity 3 12.2 12.4 14.6 14.7 17.8 17.9 Max.Overcurrent Protection 4 20 20 25 25 30 30 Min/Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size %"or/" %"or%" %"or/" %"or/" t"or 3/4" 1/2"or 3/4" UNIT WEIGHTS Equipment Weight(lbs.) 143 143 143 143 171 186 Ship Weight(lbs) 154 154 154 154 182 206 ENERGY STAR.CERTIFIED A -" NO a NO NO MOM 121=83 A Energy Star Notes Proper sizing and installation of equipment is critical to achieving optimal performance.Split system air conditioners and heat pumps must he matched with appropriate coil components to meet ENERGY STAR criteria.Ask your contractor for details or visit www.energystar.go: The www.energystacgov website provides up to-date system combinations certified to meet ENERGY STAR requirements.See Page 24 for all ENERGY STAR certified combinations as of this document's revision date. Tested and rated in accordance with ARI Standard 210/240 2 Reference TP-107*for additional application requirements 2 'entre size should be determined in accordance with National Electrical Codes;extensive wire runs will require larger wire sizes - " Must evst bine-delay fuses or HACR-type circuit breakers of t:he same size as rioted. NOTES • Always check the S&R plate for electrical data on the unit being installed. • Installer will need tosupply'A"to 1'/"adapters for suction line connections. • Unit is charged with refrigerant for 15'of%'liquid line.System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units may require the specified TXV Kit to be installed on the indoor coil.THE SPECIFIEDTXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. SS-GSZ14 www.goodmanmfg.com AHRI RATINGS ENERGY STAR® CERTIFIED COMBINATIONS A OUTDOOR INDoonthars anncoouNG RATINGS A TVA R'A'TINGS 3 HEATING RATI UNIT COI LVARIAMPILEtS Tara SENS. SEER' EER 2 TOTAL SENS. HI' HSPF s LOW 6 CFM AHRI * GSZ14 ASPT29614A* 18,000 14,200 15.0 12.5 17,400 13,900 17,200 8.5 10,000 565 8242614 0181K* ASPT29B14A* 23,400 18,700 15.0 12.5 22,600 18,500 23,200 8.5 13,400 790 8242618 ASPT30C14A" 23,400 18,700 15.0 12.5 22,600 18,500 23,200 8.5 13,000 800 8669637 GSZ14 0241K* AVPTC30C14A* 23,400 18,700 15.0 12.5 22,600 18,500 23,200 8.5 13,000 800 8875166 CA*F3636*6D*+MBVC1200**-1A*+TXV 23,600 18,900 15.0 12.5 22,800 18,700 23,200 8.5 13,000 855 7995059 ASPT37C14A* 28,400 21,000 15.0 12.5 27,400 20,600 28,000 8.5 16,000 1,045 8242621 GSZ14 AVPTC30C14A* 27,800 20,600 15.0 12.5 26,800 20,000 28,000 8.5 16,000 860 7995114 0301K* C4*F3642*6D*+MBVC1200**-1A*+TXV 28,000 20,800 15.0 12.5 27,000 20,200 28,000 8.5 16,200 855 7995147 ASPT47D14A* 34,800 25,800 15.0 12.5 33,600 25,200 32,600 8.5 20,000 1,180 8242629 GSZ14 CA*F4860*6D*+MBVC2000**-1A*+Ty,V 35,600 26,400 15.0 12.5 34,200 25,800 32,800 9.0 20,000 1,160 7995271 0361K* CA*F4961*6D*+MBVC1600**-1A*+TXV 35,600 26,400 15.0 12.5 34,200 25,800 32,400 8.5 20,000 1,075 7995304 ASPT47D14A* 38,500 29,200 15.0 12.5 37,200 28,600 38,000 8.5 23,000 1,205 8242633 AVPTC42D14A* 39,500 30,000 15.0 12.5 38,000 29,400 39,000 8.5 23,000 1,220 7995403 GSZ14 0421K* C:A*F4961*6D*+M8VC1600**-1A*+TXV 40,000 30,400 15.0 12.5 38,500 29,600 39,500 9.0 23,800 1,300 7995449 CA*F4961*6D*+MBVC2000**-1A*+TXV 40,500 30,800 15.0 12.5 39,000 30,000 39,000 9.0 23,800 1,310 7995451 GSZ14 CA*F4961*6D*+MBVC1600**-1A*+TX,V 45,500 36,000 15.0 12.5 44,000 35,000 44,500 9.0 27,600 1,500 7995551 0481K* CA F4961*6D*+MBVC2000**-1A*+TX,V 46,000 36,400 15.0 12.5 44,500 35,400 44,500 9.0 27,600 1,570 7995553 ^ Proper sizing and installation of equipment is critical to achieve optimal performance.Split system air conditioners and heat pumps must be matched with appropriate coil com- ponents to meet ENERGY STAR'*criteria.Ask your contractor for details or visit www.energystar.gov.The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements. > Rated in accordance with ANSI/AHRI Standard 210/240 Seasonal Energy Efficiency Ratio z. Energy Efficiency Ratio @ 80'E/67'F/95"F WA Rating:BTU/h @ 75`11 63'r-95°F ° Rated healing capacity at 47'F outdoor per AHRI 2.10/240 HSPF=Heating Seasonal Performance Factor 5 Heating capacity at 17'F outdoor CFM at High stage n CFM at Intermediate and low stage NOTES • Always check the S&R plate for electrical data on the unit being installed. • When matching outdoor unit to indoor unit,use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit. • LEP-Order from Service Dept.Part No.B13707-38 or new Solid State Board B13707-355.Part No,B13707-38 is not interchangeable with 813707-35S. The Goodman brand gas furnace contains the HP cooling time delay. 34 www.goodmanmfg.com SS-GSZ14 to 8 7 6 5 4 3 2 1 G7 N ECN REV ZONE DESCRIPTION :HK D DATE N xxxxxxx A xxxxx - GL -P E DIMENSIONS E MODEL W" D" H" -.., 657.140181/191** 29 29 34% 35 F ✓ 657140741/251** 29 29 34% W "'" ,r'-f ``-.,� 657140301.** 29 7.9 36% ` GS7140311A* 35r%, 34% D D `� 657140361** 29 29 36:6 D G57140371A* 35% 35% 40 $ lf � 657140421** 35 4 3S% 39% �N -IT N 65Z140481*' 29 29 36% Z :-.><:^--� � '� ���� ' G57140491** 35% 35% 34% kk ' ...,,,,‹-.;",,,-'',.::::.i, 0 ,‘.1 -.:",,..„. ��lli4l�` � �A !� '� 'l ��1� 657.140601** 35% 35;h 34% * i 114 III�> `n tee--= lrE, rl�i C 1 '611 i .i, mow' -y''' 1$�1'" ( 0i` o ti ' IPill 1 Iio 1:le ll B til �/��41 ti, ., B 711ii,01 liiI1 • Goodman Manufacturing Co.,L.P. A "`,71 GSZ14 A SPECIAL CHARACTERISTICS: CIXNPONENTSPry"rw1rERIGL55PECIFlEOHEH[IN wlvuso coNvow.+ro me nvvucoe�c SDCTION or GOODMAN Msv 826"1 WORKMANSHIP a owN SO, IErvA. I� SrANOP"O fOH Ni,EEELONO FINISH. SHT 1 11 a ©=6SIGMA CRITICAL CHARACTERISTIC S E SIGNIFICANT CHARACTERISTIC %.r,_ "3 REV Pr ArNOPI�oINw�l"H�MNn"E"En"NE""PSN"EM ry "NL"MaE,"N"P"�EP.�P" PNSEP""SHIN Irw«E TUB L_ A 8 7 6 5 4 3 23 1 rn m 2 Ln Q W 2 • LVJB Cay, CONTROL BOX OUTDOOR POWER SUPPLY "- - OR o SEE NOTE 1 SEE RATING PLATE b WH W2 I RD R I C) ------- BL/PK Y 2 CD 1N •l DC RD r BL C 11 ®® •. . • • • S T2 COLOR CODE 5 SR 2 .1 BK... •�<2 r —Ir r6p, -� BK BLACK c" 1.2 G) o a, BL/PK BLUE/PINK STRIPE l• RD ) L • A LoJ•< ) BR BROWN H C ...; rL,;1 •-( v ) GR GREEN y ' w� • 0 re' ' RCCF OR ORANGE w -1, -, w • • COMP F 1 A PU PURPLE oo „DFI C y9s,:, I F 1 s 1 1 O RD------------RED �Q HVDR 1' CR BK " BL WH- ---- -WHITE a'' 'I( YL YELLOW w o •DF2 SA v ..... V v B I 1 YL/PK---------YELLOW/PINK STRIPE Q-2-' p ` WH BK BK OR NOTE 2 YbPK BUPKj PU WIRING CODE RD • FACTORY WIRING KHIGH VOLTAGE s• • `+ LOW VOLTAGE r n e SC OPTIONAL HIGH VOLTAGE ®--- -♦ P -nrr�< ... FIELD WIRING _ cm 'k5,t, BL L HIGH VOLTAGE LOW VOLTAGE — — — — CHS CH I f K BK yi B ...c • -^ -^-- I COMPONENT CODE �' SEENOTE4 * T1 T2 C CONTACTOR RDFT DFT„ DFT C * : sR � CADM COMFORT ALERT DIAGNOSTIC MODULE • • =IIM S PU L1 L2 D I CCR---------COMPRESSOR CONTACTOR RELAY • OIII BK C p CH---------CRANKCASE HEATER R PSI• 11 PS2 -'• O • .Lr ,� a. — e ...� � CHS------CRANKCASE HEATER SWITCH LVDR • J�RD CM-------OUTDOOR FAN MOTOR R • • • LPS 0-RV RVCRV fl) 4. PU -RD CMR --- --CONDENSER MOTOR RELAY 7 s. COMP----COMPRESSOR o """"�° - ©©O�RCCF CS COMPRESSOR SOLENOID • W..... co T c O ! t I DC DEFROST CONTROL • • C DFT DEFROST THERMOSTAT CCR • • 3 O T1�T21 ; ....YL.."v i DT DISCHARGE THERMOSTAT JOy� T TT -+-- — -- ~ — �YL . HPS---------HIGH PRESSURE SWITCH HPS LIT L20 ® .. BR 1 3A 1 HVDR------- HIGH VOLTAGE DEFROST RELAY ALTERNATE i3D 1 pF USED) 10 INTERNAL OVERLOAD RDOUBLE POLE BKIRD NOTE2 � LPS -- LOW PRESSURE SWITCHW2 O YFIELD LOW CONTACTOR BUR< BL/PKLVDR------LOW VOLTAGE DEFROST RELAY yap BK) SEE NOTE 4 I y I 1 LVJB-----LOW VOLTAGE JUNCTION BOX 1--INDOOR POWER SUPPLY --�-I.7�7 CONNECTIONS L., 1 RCCF-----RUN CAPACITOR FUR COMPRESSOR&FAN SEE NOTE 5&6 DFT RVC HPS BK I `� RVC-------REVERSING VALVE COIL It SEE NOTE 1 b,�,y. BK 1_ SA----------START ASSIST lell ., l CHS ° 1 SC---- START CAPACITOR FOR COMPRESSOR(OPTIONAL) EQUIPMENT GROUND SR START RELAY FOR COMPRESSOR(OPTIONAL) COMP CH �� SEE NOTE 3 CONTROLS SHOWN WITH THERMOSTAT IN'OFF'POSITION. /'� NOTES // MAIN G 4 PL✓ yUpK 1.TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK&INDOOR THERMOSTAT. (le; ' l". BK RD 'I�' GH 2.START ASSIST FACTORY EQUIPPED WHEN REQUIRED. ,',n, BR✓ ll? 3.USE COPPER CONDUCTOR ONLY. \ to , YL/PIC, YL 4.CRANKCASE HEATER&CRANKCASE HEATER SWITCH ARE FACTORY INSTALLED OPTION. �. \• • LPS ® F • - -- CRANKCASE HEATER MAY NOT HAVE ADDITIONAL GROUND WIRE 5.40VA MINIMUM TRANSFORMER IS REQUIRED. •' ere CM 0 6.COMMON SIDE OF TRANSFORMER MUST BE GROUNDED. t--t- USE N.E.C.CLASS 2 WIRE 0140R00171 -D in C) Wiring is subject to change.Always High Voltage:Disconnect all power before servicing or installing this unit. Multiple power rolesNI A to the wiring diagram or the WARNING sources maybe present.Failure to do so may cause property damage,personal injury,or death. unit for the most up-to-date wiring. ACCESSORIES MoDEI# QESCRIPiIQN GSZ14 GSZ14 GSZ14 GSZ14 GSZ1.4 GSZ14 0181/191** 0241/251** 0301** 0311** 0361** 0371** ABI 20 Anchor Bracket Kit" X X X X ASC-01 Anti-Short Cycle Kit X X X X X X A5E18-60A Ali-fuel Kit X X X X OT/EHR18-60 Emergency Heat Relay kit X XX X FSK01A1 Freeze Protection Kit X X X X X X CSR-U-1 Hard-start kit X X X X X X LAKTOIA Low-Ambient K!t X X X X X X 01303000005 Low-Pressure Switch Kit X X X X 0T18-50A2 Outdoor Thermostat X X X X X X TX2N4A 3 T:XV Kit X X TX3N43 TXV Kit X X X X TX5N43 TXVPit Contains 20 bracl.ets,four brackets Needed to anchor unit to pad Instated on indoor cot Required for heat pump applications where ambient temperatures fall below 0"F with 50%or higher relative humidity. 3 Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid it TheTXV should always be sized based on the tonnage of the outdoor unit. GSZ14 GSZ14 f 14' M �Ay: DESCRI 0421** 0481/491**i. ** ABK-20 Anchor Bracket K t" 1 if ,. X ASC-01 Anti-Short Cycle Kit X X X AFE18-60A All-fuel Kit X '„: X CST,/EHRS8-60 Emergency Heat Relay kit X X X FSK01A,' Freeze Protection Kit X X X CSR-U-1 .Hard-start Kt X X LAI TOIA Low-Ambient Kit X X X 0130R00000S Low-Pressure Switch Kit X X X 0T18-60A2 Outdoor Thermostat x X X TX2N4A 3 TXV Kit TX3N4 s TXV Kit TX5N4 3 TXV Kit X X I X ° Contains 20 brackets:four brackets needed to anchor unit to pad Installed on indoor coil Required for heat pump applications where ambient temperatures fall below 0'F with 50%or higher relative humidity. Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit.The TYV should always be sized based on the tonnage of the outdoor unit. SS-05714 www,good ma n mfg,com 55