Loading...
Specifications (35) r(-\ c;a0r (3:A0 RECEIVED `C VC • OCT VS 2018 CITY OF TIGARD STRUCTURAL CALCULA11O !VJSIO FOR Hunziker Center Suite 7460-G RTU Replacement Tigard, Oregon ' ELLIOTT ASSOCIATES 901 NE Glisan Street Portland, Oregon 97232 T 7,7 4.11 ti„,„ Consultants f Structural Engineers a S: 06-3O-202 ioo East 13th Street• Suite io •Vancouver, Washington 98660 Phone: (503) 384-0460 • (36o) 699-0607 ROOF TOP UNIT '.•-- -- 2_#12xREQ'D SCREWS, EACH SIDE OF UNIT (E)UNIT SUPPORT, - BY MANUF (1) 16 GAL 3"x1?"x0'-1i"w/(3) #10 SCREWS AT(E)CURB& (", #10x2" @ f=A j5 d ( ) 7TZUs5 c //.\ A ROOF TOP UNIT SUPPORT DETAIL • NTS 1/4 _ 7U , , -1.)1,4--c-0 19 .r' 5-c),Pf'cv2-r D e .iv 4,,x 9rzi to AJUF (J55 e 5 '''Pptczo AT Ka.44 (pe... , 5p4d . .c7 / .-vppeAT 11 0. Jo,,„, P /3 7-s -col,/ = i i .e>0 P .". ArA ' \ -TX,v5 5 e...._ i4-AVE- .5e_ \) D ._ I(Tr,/,e-lo 64-7/ me4_,.+440, c..- ?r- .4_ , d z-7 40 F5 F.- M P4--5 Vik) c e70 ( -v=31/6) -/- e.o ( e7) C31l4- z./.0) I f-?C) (39/4) -.;-- i ?1 & .5 <2, 14. 0 0 )4- Bp: Pro) Sob ho. Associated Hunziker Center Suite 7460-G RTU 18-271 ICConsultants, mat°n Date inc, Structural Engineers Tigard, Oregon 09/06/2018 Client ,00 East 13th Street•Suite 10•Vancouver,Washington 98660 NAI El 1 1on Sheet No./ Elliott PortlaPortland:(503)334-0460 • Vancouver:(360)699-0607 1 • 5 -/z2641 f . 4 e, )673) (e/2 ) 1 2--(V11)) &c=") - 35 (3o) rat c21-74 ` ge) C` 7) (')<- CJ2s ( f7 ?, ,�5� Fff -.-_-_- 17, 6 , 0, ,a i„ ) 7 1 / --1 i ( x ) -------‘ -,e:A0 ° 16-- 1 -t/ : / 7,<.6 (0"/ ./1(.5 z, a5 .116,=— 'CT-N .------ er,(‘- /,5) •A 450 (3b0 - gr:3C/,,5,, = , Ii )f 4-117- 4 (ILS° / .9 ,/ Vi 4 �i��D (' cy'a) - 5 _ __ A----r-r4444I.7"'u a 16-,>c, `, v i< 6 0/ 2. _ .. /© .Sc - L7 - 41 b r---C 0 ) .- Sad > , 5O o K.. Bp: Project doh No. Associated Hunziker Center Suite 7460-G RTU 18-271 oz, Consultants Location Date Inc. 5huctutaiEngneee Tigard, Oregon 09/06/2018 Client No. 100 East 13th Street•Suite 10•Vancouver,Washington 98660 NAI f11 I Eliiott sheet:3./5 Portland:(503)334-0460 • Vancouver.(360)699-0607 V 1 J N 8 7 6 5 4 3 2 1 ECN REV ZONE DESCRIPTION :HK D DATE N X%%XMX. A %%XX% -- GL E DIMENSIONS E MODEL W" DN H" GSZ140181/191** 29 29 3414 V � 0 GSZ140241/251** 29 29 34% — • W 1` 5 �/! ' GSZ140301** 29 29 36% GSZ140311A* 35%: 351/2 34% D '✓/y,5 ` D /"� GSZ140361** 29 29 36'% 0 �y��`{�• j�t:1 r *+t\ GSZ140371A** 35Yz 35%z 40 ia,�,t t�/f4 z GSZ140421 35%: 35'/: 39% 7:*' �, ,...7- GSZ140481** 29 29 36% — f " � G52140491** 35%z 35Yz 34% 1 t C ‘11''[1114.41/..,,,,,.. �d �Irj� tli �l, GSZ140601** 35%z 35% 34Y 1 ,,,,Z Iii,aiii� illl1 h 1 1 111I,11i11j i; o • 11* 1 I ii1 -li, i11j1"11'itd. P1' 'ipilzili4,iii iii iilt�!01.,,,,,,I:1 . co 1111 II 11 101101'l 1 H 3 4d ,'IpiLiil1y,111 a 0 jii .1'• ov il;,ilr'I i it AiIIH l iil�lll�ls!!�= ' 0111 11111 - .f.;',:„.',....1,„--4,,,,.'.,y Goodman Manufacturing Co.,L.P. A SPECIAL CHARACTERISTICS: �R oNKEro, GSZ14 A COMPOMfO AND FEEL AND HEREIN WILL ALSO CONFOR M TO THEAPPF�URLESECTION OF fiCOOMAN MEP R2C.01WOR%MANS W IMFMK[1 NBr'. 'ENG' Jo0 STANDARD FOR M.FEEL Arm FINISN its ( SHT30F l� Q=651GMA CRITICAL CHARACTERISTIC SIGNIFICANTCHARACTERISTIC cpNFrueNrlALVRpRerrc DFrNewpoMAN M.Nux cruwuu COMPANY,LP.NprroRr usapsED 1p prrR Rs,rowEn.pR uscp TpxANr w2RPasE Ru GTO��.«sr Da 0� REV WEPT AS AIM ORIRED IN LARDING.MUST*E RETURNED UPON%MAW.ON COMPaTION OF OAOF.M mNFRPURPOSF EEM wNIUr n wASLfNr. A 8 7 6 5 4 3 2 1 f1 m 6) rs O W Z H Lei _r PRODUCT SPECIFICATIONS(CONT.) U +V f = IGSZ14 GSZ14GSZ14 GSZ14 GSZ14 GSZ14 0361K* 0371A* I 0421K* I 0481K* I 0491K* I 0601K* NOMINAL CAPACITIES Cooling(BTU/h) 36,000 33,000 42,000 48,000 48,000 60,000 Heating(BTU/h) 36,000 34,000 42,000 48,000 48,000 60,000 Decibels 74 73 75 75 76 76 COMPRESSOR RLA 15.4 14.1 16.7 18.5 19.9 26.4 LRA 83.9 72.2 109.0 124.0 109.0 134.0 Type Scroll Scroll Scroll Scroll Scroll Scroll CONDENSER FAN MOTOR Horsepower 1/6 1/4 1/6 1/4 1/6 1/4 FLA 0.95 1.30 1.1 1.30 1.1 1.30 REFRIGERATION SYSTEM -, Refrigerant Line Size' Liquid Line Size("O.D.) /" /" %" yg," %" Ye" Suction Line Size("O.D.) Ye" '/g" 1%' 1%s" 1%8" 1'/s" Refrigerant Connection Size Liquid Valve Size("O.D.) I8' 3/" '/8' %" 3/" 3,,8" Suction Valve Size("0.0.) %" No %8' %8" %S' 7h'• Standard Line Set Length(max.feet) 80 80 •80 80 80 80 Long Line Set Length(max.feet)2 Equivalent Length 250 250 250 250 250 250 Linear Length 200 200 200 200 200 200 Vertical Length(outdoor below indoor) 80 80 80 80 80 80 Vertical Length(outdoor above indoor) 80 200 80 80 80 80 Valve Connection Type Sweat Sweat Sweat Sweat Sweat Sweat- Refrigerant Charge 112 175 140 133 187 205 ELECTRICAL DATA _ Volts/Phase(60 Hz) 208-230/1 208-230/1 208-230/1 - 208-230/1 208-230/1 208-230/1 Minimum Circuit Ampacity 3 20.2 18.9 22.0 24.4 26.0 34.3 Max.Overcurrent Protection 4 35 30 35 40 45 60 Min/Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size /x'or%." 1/2"or 3/4" /z"or/" %z"or%" 'S"or 3/4" %"or " UNIT WEIGHTS . Equipment Weight(lbs.) 173 220 191 226 273 277 Ship Weight(lbs) 184 240 207 237 288 292 ENERGY STAR°CERTIFIED A NO . -P' NO NO amassi A Energy Star Notes Proper sizing and installation of equipment is critical to achieving optimal performance.Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria.Ask your contractor for details or visit www.energystargov. The www.energystacgov website provides up-to-date system combinations certified to meet ENERGY STAR requirements.See Page 24 for all ENERGY STAR certified combinations as of this document's revision date. ., ' .Tested and rated in accordance with ARI Standard 210/240 2 Reference TP-107"for additional application requirements " Wire size should be determined in accordance with National Electrical Codes;extensive wire runs will require larger wire sizes 4 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. • Installer will need to supply'/"to 1!"adapters for suction line connections, • Unit is charged with refrigerant for 15'of 34"liquid line.System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil.THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. 4 www.goodmanmfg.com SS-GSZ14 Gi r."._