Loading...
Specifications (36) tt 53 Sv314 ROWELL R1 o�c 10570 SE Washington St Suite 212 ENGINEERING, LLC Portland,OR 97216 STRUCTURAL ENGINEERING Tel. 503-254-6292 Fax.503-254-6761 STRUCTURAL ANALYSIS RECEIVE 00 _4201% October 4, 2018 1.1G1\Cli t4 BUICCOG„1V`S1® LU'S SPORT BAR 11530 SW PACIFIC HWY TIGARD, OR 97223 120 mph Ultimate Wind, Exposure B Seismic Category D 2015 IBC /2014 OSSC Rowell Engineeringco PR0A" Project Number: 4;� GINF�s` R-18-046 �� 597P E/00; / /�� C� EGt3 T, RO' (93 EXCLUSION OF LIABILITIES I.DISCLAIMER AND RELEASE BUYER HEREBY WAIVES,RELEASES AND RENOUNCES ALL WARRANTIES(EXPRESS OR IMPLIED),OBLIGATIONS,AND LIABILITIES OF ROWELL ENGINEERING AND ALL OTHER RIGHTS,CLAIMS AND REMEDIES AGAINST ROWELL ENGINEERING(EXPRESS OR IMPLIED)WITH RESPECT TO ANY NONCOMFORMITY,IMPROPER INSTALLATION, WORKMANSHIP OR MATERIALS. II.EXCLUSION OF CONSEQUENTIAL AND OTHER DAMAGES ROWELL ENGINEERING SHALL HAVE NO OBLIGATION OF LIABILITY,WHETHER ARISING IN CONTRACT (INCLUDING WARRANTY),TORT(INCLUDING ACTIVE,PASSIVE OR IMPUTED NEGLIGENCE)OR OTHERWISE,FOR LOSS OF USE,REVENUE OR PROFIT,OR FOR ANY OTHER INCEDENTAL OR CONSEQUENTIAL DAMAGES. III.THIS PRODUCT IS FOR A SINGLE USE ONLY AND IS NOT TO BE REUSED WITHOUT SPECIFIC AUTHORIZATION. Page 4 ko4P/7'4:-.4 1711//1/11 17'049 , - ,L-I 61' -PSI ( i-- o I -I:) ) :::' 4r/3 a, e,,, „:„. r4r 'S J /9- I-07ALoFr -- Yp Foi-rj � .r ,i TrmA7 .ka) vi, i „,,,,,,- FA,,,,,v,,,,,,,,, 6.i... 4,. I - 0,, 1 , i is ' ' - ,r 'O['/ r 7,L ENG 1z\7.::i:P.11 '"6.7 Br 1)at 'a j olec.'c Sh'e'er.__._. -'i____�— Page 5 '4:4)/(4-1.2.//Y 144442 4,0,41), — 1-1, h pi! ( fr2,-I ft ) a 1,9vo ‘, / (/ 4d0'` , / Jar-.x' 4 0. - - < '2..-i6' : /v1 / 40/4/6 r r 13-00 V ------ : l ` ° r k 1 VE L L ENGINE RI,\ T ' 6 j Date (0- 3 i Page 6 SIMPSON Anchor DesignerTM Company: ROWELL ENGINERING LLC Date: 10/3/2018 Engineer: CT Page: 1/5 ' Software Project: LU'S SPORT BAR Version 2.6.6682.0 Address: a Phone: E-mail: 1.Proiect information Customer company: Project description:Retro-fit anchors Customer contact name: Location: Customer e-mail: Fastening description:StI Plate to conc panel Comment: 2.Input Data&Anchor Parameters General Base Material Design method:ACI 318-14 Concrete:Normal-weight Units: Imperial units Concrete thickness,h(inch): 18.00 State:Cracked Anchor Information: Compressive strength,f0(psi):2500 Anchor type:Concrete screw 4ic,v: 1.0 Material:Carbon Steel Reinforcement condition:A tension,A shear Diameter(inch):0.500 Supplemental reinforcement:Not applicable Nominal Embedment depth(inch):3.500 Reinforcement provided at corners: No Effective Embedment depth,het(inch):2.560 Ignore concrete breakout in tension:No Code report: ICC-ES ESR-2713 Ignore concrete breakout in shear:No Anchor category: 1 Ignore 6do requirement: Not applicable Anchor ductility:No Build-up grout pad: No hmin(inch):5.42 cec(inch): 3.88 Cwn(inch): 1.75 Sin(inch):3.00 Recommended Anchor Anchor Name:Titen HD®-1/2"0 Titen HD,hnom:3.5"(89mm) Code Report: ICC-ES ESR-2713 ern . Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. `.)z, 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com Page 7 SIMPSON Anchor DesgnerTM Company: ROWELL ENGINERING LLC Page: 21105/3/2018 Engineer: CT SoftwareProject: LU'S SPORT BAR Version 2.6.6682.0 Address: Phone: E-mail: Load and Geometry Load factor source:ACI 318 Section 5.3 Load combination: not set Seismic design:Yes Anchors subjected to sustained tension:Not applicable Ductility section for tension.. 17.2.3.4.2 not applicable Ductility section for shear: 17.2.3.5.2 not applicable 00 factor: not set Apply entire shear load at front row:Yes Anchors only resisting wind and/or seismic loads:Yes Strength level loads: N.[lb]: 0 V..[lb]: 0 Vuay[lb]:266 <Figure 1> 0 lb :01±01FAIE01,4111011111ill filar fi'ASE724:-:Ni:ilikailL',1,,4010411111111110111'Offir ...!-100!!!111,,.:10.0001:10K-bi, 0000000M,'- '1:140401ReigitaP 266 lb 'OOO:.O:.O,O.O:.:2.4;;14110111X1.14- O-O-- Y X :opy. o3O,ik C.-X5 5:1",,,;OO OO411: Input data and results must be checked for agreement with the existing circumstances,the standards and guidelinesmust bechecked wvmie hecked.sfotrropnlgatus.icboniility. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone: 925.560.9000 Fax:925.847.3871 6 Page 8 SIMPSON Anchor DesignerTM Company: ROWELL ENGINERING LLC Date: 10/3/2018 Engineer: CT Page: 3/5 ° `g , °P Software Project: LU'S SPORT BAR • Version 2.6.6682.0 Address: Phone: E-mail: <Figure 2> Q 1-1 1 4.00 1. 4.00 Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com Page 9 SIMPSON Anchor DesignerTM Company: ROWELL ENGINERING LLC Date: 10/3/2018 Engineer: CT Page: 4/5 Software Project: LU'S SPORT BAR Version 2.6.6682.0 Address: Phone: E-mail: 3.Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Nua(lb) Vuax(lb) Vuay(Ib) J(Vua),)2+(Vuay)2(Ib) 1 0.0 0.0 266.0 266.0 Sum 0.0 0.0 266.0 266.0 Maximum concrete compression strain(%o):0.00 Maximum concrete compression stress(psi):0 Resultant tension force(lb):0 Resultant compression force(Ib):0 Eccentricity of resultant tension forces in x-axis,e'Nx(inch):0.00 Eccentricity of resultant tension forces in y-axis,e'Ny(inch):0.00 Eccentricity of resultant shear forces in x-axis,e'vx(inch):0.00 Eccentricity of resultant shear forces in y-axis,e'vy(inch):0.00 8.Steel Strength of Anchor in Shear(Sec.17.5.1) Vsa(lb) Ogreut 0 0grout0Vsa(lb) 4790 1.0 0.60 2874 9.Concrete Breakout Strength of Anchor in Shear(Sec.17.5.2) Shear perpendicular to edge in y-direction: Vby=mini7(Ie/da)°'24daAalif'cca,l'5;9Aa4f'ccat1•5I(Eq. 17.5.2.2a& Eq. 17.5.2.2b) to(in) da(in) f'o(psi) ca,(in) Vby(ib) 2.56 0.500 1.00 2500 4.00 2745 OVcby=¢(Avc/Avon)Y'eav9'c,v5"e,vVby(Sec. 17.3.1 &Eq.17.5.2.1a) Avo(in2) Avco(in2) Y'ed,v Pc,V Fi,,v Vby(Ib) 0 0Vcby(Ib) 72.00 72.00 1.000 1.000 1.000 2745 0.75 2059 ShearY arallel to edge in -direction, p g Vsx=minI7(le/da)°24daAa-if'cca,'5; 9AaIfceall`'I(Eq. 17.5.2.2a&Eq. 17.5.2.2b) le(in) da(in) Aa f'c(psi) ca,(in) Vex(Ib) 2.56 0.500 1.00 2500 8.00 7763 ¢Vcby=0(2)(Avc/A vac)tFed,vY'c,vYn,vVbX(Sec. 17.3.1, 17.5.2.1(c)&Eq. 17.5.2.1a) Avc(in2) Avco(in2) Y'ed,V Y'c,v Tray Vbx(Ib) 0 ¢Vcby(Ib) 96.00 288.00 1.000 1.000 1.000 7763 0.75 3882 10.Concrete Pryout Strength of Anchor in Shear(Sec.17.5.3) 0Vcp=OkcpNcb=Okop(ANc/ANco)Y'ed,NY'c,nt Pcp,NNb(Sec. 17.3.1 & Eq. 17.5.3.1a) Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com Page 10 SIMPSON Anchor DeSlgnerTM Company: ROWELL ENGINERING LLC Date: 10/3/2018 Engineer: CT Page: 5/5 Software Project: LU'S SPORT BAR Version 2.6.6682.0 Address: Phone: E-mail: kcp ANc(in2) ANco(in2) y'ed,N gic,e Pcp,N Nb(Ib) 0 0Vcp(Ib) 2.0 58.98 58.98 1.000 1.000 1.000 3482 0.70 4874 11.Results 11.Interaction of Tensile and Shear Forces(Sec.D.7)? Shear Factored Load,V.(Ib) Design Strength,eVn(lb) Ratio Status Steel 266 2874 0.09 Pass T Concrete breakout y+ 266 2059 0.13 Pass(Governs) Concrete breakout x+ 266 3882 0.07 Pass(Governs) Pryout 266 4874 0.05 Pass 1/2"0 Titen HD,hnom:3.5"(89mm)meets the selected design criteria. 12.Warnings -Per designer input,the tensile component of the strength-level earthquake force applied to anchors does not exceed 20 percent of the total factored anchor tensile force associated with the same load combination.Therefore the ductility requirements of ACI 318 17.2.3.4.2 for tension need not be satisfied—designer to verify. -Per designer input,the shear component of the strength-level earthquake force applied to anchors does not exceed 20 percent of the total factored anchor shear force associated with the same load combination.Therefore the ductility requirements of ACI 318 17.2.3.5.2 for shear need not be satisfied—designer to verify. -Designer must exercise own judgement to determine if this design is suitable. -Refer to manufacturer's product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. ':c 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com