Loading...
Permit (106) CITY OF TIGARD MASTER PERMIT � COMMUNITY DEVELOPMENT Permit#: MST2018-00272 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/25/2018 7 r .... R[, 9 Parcel: 1S125DC01900 Jurisdiction: Tigard Site address: 7065 SW VENTURA DR Subdivision: WASHINGTON SQUARE ESTATES Lot: 9 Project: BURKE Project Description: Deck replacement for first and second stories:260 sq.ft.for second story and 58 sq.ft.for first story. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement 0 sf Left: 5 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 20 Smoke Dwelling Units: 0 Third: 0 sf Right: 5 Detectors: Total: 0 sf Value: $15,000.00 Rear: 15 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF RainStorm Sewer: 0 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add.'500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Ecompasing: N Other: N Other Description: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 0 Owner: Contractor: BURKE,LAURIE TNT BUILDERS INC Required Items and Reports(Conditions) 7065 SW VENTURA DR 35897 BRYANT DR SW TIGARD,OR 97223 ALBANY,OR 97321-7502 PHONE: PHONE: 541-926-3117 FAX: 541-926-3657 Total Fees: $648.77 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are, set forth in OAR 952-001-0010 through OAR 952-001-0090. You ay obtain a copy of the rules or direct questions to OUNC by calling,.232.1967 or 00.332.23E,‘./../ Issued B Permittee Signature: "T—�' ` 1.--"/' Y 9 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 'fling Permit ApplicatioR � ' Residential FOR OFFICE ISE ONLI' City a Tigard `t r I - 8 2•011 Received 64,...., " 13125 SW Hall Blvd.,Tigard,OR 97223 1' Date/By: Jeri/or j Permit No.:, �- /5� ���12 !: TIG ARD Plan Revie �,�f vs t7a+� V� Phone: 503.718.2439 Fax: 503.598.III T' DateBy: ktji ti Is-- Other Permit: TI C A R D Inspection Line: 503.639.4175 � C ] Date Ready/ Jill-IS g s: ® See Page 2 for Internet: www.ti and-or. ov BBINS � , . fied/Method, hig g �l� aSupplemental Information TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING 0 New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ® 1-and 2-family dwelling 0 Commercial/industrial Valuation: $15000 ❑Accessory building 0 Multi-family Number of bedrooms: ❑Master builder 0 Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:7065 SW Ventura Dr New dwelling area: square feet City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Deck Replacement Covered porch area: square feet Cross street/directions to job site: Deck area: 318 square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. 260 sqft second story and 58 sqft first story deck replacements Valuation: $ Existing building area: square feet New building area: square feet C. PROPERTY OWNER 0 TENANT Number of stories: Name:Laurie Burke Type of construction: Address:7065 SW Ventura Dr Occupancy groups: City/State/ZIP:Tigard,OR 97223 Existing: Phone:(541)926-3117 Fax:( ) New: ® APPLICANT 0 CONTACT PERSON BUILDING PERMIT FEES* Business name:TnT Builders inc. (Please refer to fee sehedule) Structural plan review fee(or deposit): Contact name:Brent Mosser FLS plan review fee(if applicable): Address:620 SW Queen Ave Total fees due upon application: � ) . City/State/ZIP:Albany,OR l ` rrTJ Phone:(541)926-3117 I Fax::( ) Amount received: E-mail:plans@tntbuildersinc.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTOR Commercial and residential prescriptive installation of roof-top mounted Photo Voltaic Solar Panel System. Business name:TnT Builders inc. Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:620 SW Queen Ave Solar Installation Specialty Code checklist. City/State/ZIP:Albany,OR 97322 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(541)926-3117 I Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:105770 Total fee due upon application: $201.60 Authorized signature: '/ This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Brent Mosser Date:10/3/18 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) City of Tigard Iiiii 114 COMMUNITY DEVELOPMENT DEPARTMENT TIGARD Building Permit Review — Residential __, -_. -7-7,7.0•_: `-",:_:.-_...-_...� e Building Site Address: Project Name: ez . GAJ Ven ,„ (,ie �cie 4,4 ,,,,,,, Lot #: _ (New'welling=subdivision name;Additi. or Alteration=last name of owner) Planning Review Proposal: 'mak ohC' rift'site address/suite#exists and active in permit system. Terrace Neighborhood: ENo ❑ Yes,See River Terrace ReviewAddendu Site Plan Elements:ein- m Attached Three(3)copies of site plan J S� e plan must be on 8-1/2"x 11"or 11 x 17"paper e sag-xig structures on site , rawn to scale(standard architect or engineer scale) �or new structure(including decks)with finished .Q.PdSrth arrow floor elevations '2(ite address,project or subdivision name and lot number USiclewalleors-&-easements (required for new and additions) pplicant information(name and phone number) -aPProach �.ot dimensions and buildingsetback ��" septic systems dimensions cLF-xistirig-trees to be retained with drip buildings to be demolished line,and tree • protection measures coverage area,percentage of coverage and impervious area(applicable if R-7,R-12,R-25&R-40) c'type and location 0�y" -er�vations(2 foot contour lines if more than >1,000s-- 4 foot differential) sf of impervious area created or replaced? Oyes ❑No ��Clean Water Services-Service Provider Letter(lot platted prior to 9/10/1995):If es,is a storm water �uah fac�h shown? ❑Yes ❑No Required: ❑ Yes,applicant was notified Cho Received: 0 Yes 0 No Public Facilities Improvement(PFI)Permit: Required: ❑ yes,applicant was notified o Applied For: ❑ Yes ❑ l-.and,Use Case#: 0 No,stop intake r - zoning: ilk_ ❑required Setbacks: Front li (j Rear Side Street Side T�+ulScape Requirement: oda Garage �(� ❑ erage Maximum: ig Height: Maximum Height Isu learance Actual Height -Sensittve'Lands: 0 Yes 0 No p_-Urban Forestry Plan Type editions "Met"prior to issuance of building permit Notes: `"Approved By Planning: f %i cr ,- Revisions (after Building Submittal only) ��� Date: ___44/./E__ Revision 1: 0 Approved 0 Not Approved Reviewer Date Revision 2: 0 Approved 0 Not Approved Revision 3: 0 Approved 0 Not Approved I:kBuildingTorms\BldgPermitRvw RES_061417.docx Building Permit Submittal Original Submittal Date: ___45fit----_ # Site Plans: # Building Plans: Building Permit#: Hier building permi____t#above. �t Coordinator ng cr— Workflow Routing: Hing eering '1 Workflow Sign-off: .gi-3ign-off for Planning(include notes from planning review) Route Application Documents: engineering: (1) copy of permit application, (1) site plan, (1)building plan and 0l plan review routing form. CeWiruilWig: original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: -.0111111111110 { Date: By Permit Technician: -- EnIineering Review 2 Vope at building pad: il. 3 9d editions"Met"prior to issuance of building 4asements (encroachments)per engineering conditions of approval and plat 1[" Water Quality/Quantity Facility: 0 No Assess Water Quality Fee in-lieu: 0 Yes 0 No Assess Water Quantity Fee in-lieu: 0 Yes 0 No LIDA Facility on lot: 0 Yes Final Plat Recorded: Date: 0 NOT Approved by Engineering: Notes: OW �� Date: �� Approved by Engineering: ,Age: Date Revisions (after Building Submittal { i )Not Approved Reviewer Revision 1: 0 Approved 0 Revision 2: 0 Approved 0 Not Approved Revision 3: 0 Approved 0 Not Approved Permit Coordinator Review N Conditions"Met"prior to issuance of building permit -_ Date: 0 Approved,NOT Released: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: SDC Fees Entered: Wash Co Trans Dev Tax: 0 Yes a N/Aa,N/A Tigard Trans SDC: 0 Yes N/A Parks SDC: 0 Yes LIDA 0 Yes N/A 4a OK to Issue Permit / Date: �� 7 Approved by Permit Coordinator: .i . j 1ABuilding\Forms\BldgPermitRvw_RES 010118.docx City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 7065 SW VENTURA DR, TIGARD, OR, 97223 Record Type: Record ID: Residential - Master Permit MST2018-00272 Inspection Type: Inspector: 299 Final inspection David Young Result: FA I L Comments: Lower level deck framing covered prior to approved inspection. Provide city approved, dry legible plans on site for inspection. Multiple guards on spiral stairs loose. Not ready for inspection at this time. Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 7065 SW VENTURA DR, TIGARD, OR, 97223 February 13, 2019 at 10:23:59 AM Record Type: Record ID: Residential - Master Permit MST2018-00272 Inspection Type: Inspector: 299 Final inspection David Young Result: FA I L Comments: Decks larger in depth than shown on approved plans by approximately 2'. Missing hangers at upper deck joist, 1st 4 from right side. No legible approved engineering on site for inspection. Provide approved engineering for decks as built. Provide addition to permit for extra deck sq footage and approved revised plans and engineering. Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 7065 SW VENTURA DR, TIGARD, OR, 97223 March 13, 2019 at 10:37:41 AM Record Type: Record ID: Residential - Master Permit MST2018-00272 Inspection Type: Inspector: 299 Final inspection David Young Result: FA I L Comments: Hangers at upper level deck joist by stairs not done as noted on previous failed inspection dated 2/13/19. 3 joist not set on beam, toe nailed to blocking. All else appears okl Violation Summary: Inspector Contractor City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 7065 SW VENTURA DR, TIGARD, OR, 97223 March 15, 2019 at 8:56:59 AM Record Type: Record ID: Residential - Master Permit MST2018-00272 Inspection Type: Inspector: 299 Final inspection David Young Result: PASS - NoCofO Comments: Correction from previous inspection complete. Violation Summary: Inspector Contractor