Loading...
Report (147) Waw.Q0\S- C\ Qa- MECHANICAL r `/ CONTRACTORS, INC. o�g "Committed to Quality" NT RAG'S Heating Air Conditioning Refrigeration Plumbing Submittal Data OCTW 1 2018 Control Dampers 8:11" i� p��®IIV��I�fI 788 Project: StorQuest Tigard - 12516 Submitted By: Portland Mechanical Construction, Inc. Attention: Paul Hettervig 2000 SE Hanna Harvester Dr Milwaukie, OR 97222 (503) 656-7400 Supplier: Johnson Air Products 2220 SE 9th Ave Portland, OR 97293 503-234-5071 Date Submitted: September 25, 2018 2000 SE Hanna Harvester Drive • Milwaukie, Oregon 97222 503/656-7400 • fax 503/655-0620 • toll free 866/656-7400 •www.pmc-g.com OR CCB# 151807 • WA# CC01 PORTLMCO24KA• ID#HVCC 1213 &PLBC 12598 SUBMITTAL Job Title: StorQuest Tigard Job Site: StorQuest Tigard Tigard, OR 97223 United States Contractor: Portland Mechanical Elevation: (ft) 108 Date: 9/20/2018 Submitted By: Danny Ruby JOHNSON AIR PRODUCTS 2220 SE 9TH AVE PO BOX 15098 PORTLAND, OR 97293 US Phone: (503)234-5071 Fax: (503)233-0451 Email Address: druby@johnsonair.com GREENHECK Building Value in Air. P.O. Box 410 Schofield, WI 54476 (715)359-6171 FAX(715)355-2399 www.greenheck.com Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 1 of 3 • Printed Date: 09/20/2018 ,GREENHECK Job: StorQuest Tigard Building Value in Air. Mark: Control Dampers Model: VCD-23 VCD-23 Low Leakage 3V Blade Volume Control Damper APPLICATION & DESIGN The VCD-23 is a ruggedly built low leakage control damper intended for applications in low to medium pressure and velocity systems.A wide range of electric and pneumatic actuators are available. RATINGS Pressure: Up to 5 in.wg-pressure differential Velocity: Up to 3,000 ft/min Channel Frame Leakage: Class 1A @ 1 in.wg 6., Leakage: Class 1 @ up to 5 in.wg , Temperature: Up to 250 F kiln PRODUCT DETAILS `� Frame Type: Channel a .10 II Frame Thickness: 16 ga Material: Galvanized ,-„ 1.25 in. Blade Action: Opposed o I, Height max t' \ (typical) -1 • Blade Seal Material: TPE Axle/Linkage Material: Steel Axle Bearings: Synthetic' Jamb Seal Material: 304 SS p.' IMI Damper Temp.Rating: 180 F Wdth Jackshafting: No Preference y 5 in._ Actuator Sizing: Default SqFt Standoff: 1.500 in. Ext.Shaft Length: Standard Multi-Section Fastening: Standard •Width and height furnished approximately 0.250 in. undersize. Sizing: Nominal •Installation instructions available at www.greenheck.com. ACTUATOR INFORMATION Actuator Type: 120 VAC CODES APPROVED Actuator Mounting: External IECC(International Energy Conservation Code) romitDIVtDE Actuator Location: Left Side compliant MIME Operating Mode: TwoPosition The AMCA Certified Ratings Seal applies to Air MIME Actuator Operation: Spring Return Leakage and Air Performance ratings. > AIR k .. Fail Position: Closed NEMA Enclosure: Least Cost Auxiliary Switches: No OPTIONS & ACCESSORIES Wall Construction: Steel Stud/Masonry SUMMARY ID# ! TAG !QTY I Width f Height I CONFIGURATION Drive Arrangement: Actuator Mfr: Actuator Model: Actuator Qty: 2-1 1 16.000 in. 18.000 in. Drive- gelimo TFB120 1 CC-11-1 FEL-0 v...-.. W,... .....W....-_...__.....v,..,w .,. �.,... ............._ 4.. ....tea.. ..aw«.,.. Drive Arrangement: Actuator Mfr: Actuator Model: . Actuator Qty: [12-2 6 56.000 in. 36.000 in. Drive Honeywell MS4120F1006 1 1 CC-21-1 FEL-0 Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 2 of 3 IGREENHECK Printed Date: 09/20/2018 Job: StorQuest Tigard Building Value in Air. Damper Drive Arrangements Job Summary -Start- Drive Arrangement: Drive-CC-11-1 FEL-0 Drive Arrangement: Drive-CC-21-1 FEL-0 Damper Drive Arrangements Job Summary -End- Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 3 of 3 Drive Arrangement Definition On multi-blade dampers (except vertical blade and Face &Bypass), they are given a drive arrangement code that helps describe the construction of the damper. The following breaks down what each number and letter represents. 22-2FEL- 2 0 00 0 © e 0 Number of sections wide Number of sections high Jackshaft I 0 Number of actuators or manual quadrants 0 Who supplies the actuators or manual quadrants ry F - FactoActuator or m C - Customer Supplied (field mounted) Manual Quadrant 0 Actuator or manual quadrant mounting E - External I - Internal B - Both internal and external 0 Actuator or manual quadrant location L - Left hand drive r. R - Right hand drive B - Both right and left IA-Damper Width�I 07 Number of jackshafts Vertical blade and face&bypass dampers are given a configuration ID number that helps describe the construction of the damper. See the following examples: Model Drive Arrangement Prefix AMD-23,33, 42 AMD AMD-42V VB DFD-210, 230; DFDAF-310; MLS DFDAF-330;SEDFD-210 FBH &FBV FB FSD, OFSD, CFSD, SMD,SEFSD, SSFSD, SESMD,SSSMD series MLS (except vertical blade models) FSD-311V, SMD-301V VB GFSD series GFSD ICD series CC IMO series MLS MBD-15&VCD series(except CC vertical blade models) VCD-xxV(vertical blade models) VB Jump-over Bracket The function of the jump-over bracket is to attach multiple damper sections together. mum 1 2.173 * 5.667 0-, ..:,,,,,,,.",::, WC 4,.... o : . :P : l' , I .P .P Jump-over Jackshaft ITEM QTY PART NO. DESCRIPTION 1 1 DAMPER 2 1 913119 BRACKET JUMP-OVER SS 3 4 415575 NUT,SPNLK 1/4-2018-8 4 4 416103 CS,1/4-20x1 5 HH,316SS �I / 0 ... ..- .. ----- ,--- . 4.1 ,<-' .--...---<?' .. '''''''7:-.. 41-lifili'll').-":?.111*(7.'"?7..... ... ............ ,,,,,,e0 /'°' •.40 I: 7'/..-.."-- -----1------- --?.--.. /1 ;. .. ...- :. . .. O''* 0 0 Belimo TFB120, 120-S, 24, and 24-S Actuators Application The TFB series actuators provide true spring return '> _ _lT;-PI operation for reliable fail-safe application and positive r,�a � close off on air tight dampers.The spring return system ' _E II,� IIINIM provides consistent torque to the damper with andlik . without power applied to the actuator.The TFBxxx-S version is provided with one built in auxiliary switches. IliPTi ` Torque rating (at rating voltage) 22 in.lb(2.5N•m)constant 6.28 in (159.5mm) Timing (at rated torque and voltage) �` � orie— SpringMotor: Less than 75 seconds 1I4.:Less than 25 seconds @-4°to 122°F _� 'I:'� ' Less than 60 seconds @-22°F t Vie► r _ �� . ,` ■II IA® Environmental Protection Ratings: — - —" Nema 2 Model Auxiliary Power Consumption Voltage SwitchRunning Holding Input in Vac T 2W 1.3W 24 VAC, 24 VDC TFB120 No Space Envelopes for VCD Series TFB p 2.5W 1.3W 100-240 VAC or Vertical Blade For Horizontal Blade D T Damper t frame y BliiiT — I / 1 \ D B /' \ T /j `\. t T idth ''T" "B" kid" Height "r" ''B" iiiy, >6 52)to<10(254) 0 3.5(89) ELM >6(152)to<10(254) 0 3.5(89) 6(152) Ir >10(254) 0 0 6(15 1 >10(254) 0 0 6(152) s imensions are in inches(mm). Dimensions are in inches(mm). Due to continuous product improvement,the actuator manufacturer reserves the right to change specifications without notice. For the most up-to-date information and maintenance,go to www.belimo.us Honeywell MS4120, MS4620, MS8120 Two Position Actuators Application 1 The MS4120,MS4620,MS8120 fast acting,two position actuators are spring return direct coupled actuators(DCA)for ,.IW on/off damper control.The actuator accepts an on/off signal from a single-pole,single-throw(spst)controller. Reversible mounting allows actuator to be used for either clockwise(cw) or counterclockwise(ccw)spring rotation. ;,- \'� 2 15/16 Torque rating (at rating voltage) � �� (74mm)' .% N Typical Holding:175 lb-in.(20 Nem) 3 15/16" ,61.„,. Stall Stall Maximum:425 lb-in.(48 N•m) (100mm) Spring Return:175 lb-in.(20 Nem) Typical Driving: 175 Ib in.(20 Nom) Model Auxiliary Power Consumption Voltage Switches Running Holding Input in Timing (at rated torque and voltage) Vac Drive Open: 15 seconds typical Spring Close: 15 seconds maximum MS4120F1006 No 0.35A, 0.15A, 120±10% 4120F1204 Yes 35W 10W 60 Hz Environmental Protection Ratings: MS4 F1005 0.20A, 0.14A, 230±10% Nema 1 MS4620F1 Yes 35W 10W 50/60 Hz Temperature MS812 002 o 45 VA 10 VA 24+20%, Ambient: -40°F to 130°F(-40°C to 55°C) M 20F1200 Yes' -10% Storage: -40°F to 140°F(-40°C to 60°C) ''`"N_ 50/60 Hz Space Envelopes for FSD, SMD and VCD Series or Vertical Blade For Horizontal Blade D —.— f 11161,11A 11 T 1 ' —is--IB T �-- Optional :I.L= + Jackshaft I, D 1 \ "T" ELIE "D" Piggyback lairTto<10(254) 0 12.7 6(152) Height No Yes (324) k ''1 grBrr atprr srprr rar254)to<18(457) 0 2(51) Mini >6(152) to<10(254) 0 12.75 6(152) 9(229) NEKEEMIll 0 0 6 MI (324) >10(254)to<18(457) 0 2(51) 6(152) 9(229) >18(457) 0 0 6(152) 9(229) Dimensions are in inches(mm). Dimensions are in inches(mm). Due to continuous product improvement,the actuator manufacturer reserves the right to change specifications without notice. For the most up-to-date information and maintenance,go to www.customer.honeywell.com