Report (151) ?0,6-CL- PORTLAND CSG$PORTLAND �P01 MEGy4y'c MECHANICAL CONTRACTORS. INC. "Gxnrnitted to Quality" c0'yTRAC'���� Heating Air Conditioning Refrigeration Plumbing Submittal Data OCT - 1 2018 Fans CITY OF TIGARD BUILDING DIVISION Project: StorQuest Tigard - 12516 Submitted By: Portland Mechanical Construction, Inc. Attention: Paul Hettervig 2000 SE Hanna Harvester Dr Milwaukie, OR 97222 (503) 656-7400 Supplier: Johnson Air Products 2220 SE 9th Ave Portland, OR 97293 503-234-5071 Date Submitted: September 25, 2018 2000 SE Hanna Harvester Drive • Milwaukie, Oregon 97222 503/656-7400 • fax 503/655-0620 • toll free 866/656-7400 • www.pmc-g.com OR CCB# 151807 • WA# CC01 PORTLMCO24KA• ID# HVCC1213 &PLBC12598 SUBMITTAL Job Title: StorQuest Tigard Job Site: StorQuest Tigard Tigard, OR 97223 United States Contractor: Portland Mechanical Elevation: (ft) 108 Date: 9/20/2018 Submitted By: Danny Ruby JOHNSON AIR PRODUCTS 2220 SE 9TH AVE PO BOX 15098 PORTLAND, OR 97293 US Phone: (503)234-5071 Fax: (503)233-0451 Email Address: druby@johnsonair.com 111 GREENHECK Building Value in Air. P.O. Box 410 Schofield, WI 54476 (715)359-6171 FAX(715)355-2399 www.greenheck.com Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 1 of 21 Printed Date: 09/20/2018 LIGREENHECK Job: StorQuest Tigard Building Value in Air. Mark: EF-1 Model: SE1-20-432-A15 Model: SE1 -20-432-A15 38.00 < 24.75- 1 \ , Sidewall Direct Drive Fan 1 l Motor Access From Int. of Bldg. l I' } II�IIri ■ 23.63 = 1iDimensional QI� WEATHERHOOD Quantity 6 GUARDl Weight w/o Acc's(Ib) 70 WALL HOUSING � Weight w/Acc's(lb) 226 DAMPER I I INTERIOR `I EXTERIOR Max T Motor Frame Size 145 Optional Damper(in.) 22 x 22 EXHAUST AIRFLOW Wall Opening(in.) 27.25 x 27.25 Performance 3.03.0 i Requested Volume(CFM) 7,000 - --••. Actual Volume(CFM) 6,655 2.5 7> --.„. 2.5 Total External SP(in.wg) 0.298 SO p Fan RPM 1750 �M Operating Power(hp) 1.49 -2.0 2.0 Elevation(ft) 108 3 Airstream Temp.(F) 70 1.5 - 1.5 3 o Air Density(Ib/ft3) 0.075 o o n. Tip Speed(ft/min) 9,163 m a Static Eff.(%) 21 D- 1.0 .. 1.0 oin yrco 6e6o deb s 0.5 0.5 o` system ._..._.._._....00 .. Motor 0.0 - - i-J ---......-Hi--.4- 1 1-1-- l I I r 0.0 Motor Mounted Yes 0 1 2 3 4 5 6 7 8 Size(hp) 1 1/2 Volume(CFM)x 1,000 Voltage/Cycle/Phase 208/60/3 Enclosure ODP L Operating Bhp pant Static Pressure Calculations Motor RPM 1750 0 Operating point at Total External SP External SP 0.33 in.wg Fan curve Direct Drive RPM Adjustment -0.032 in.wg Windings 1 System curveTotal External SP 0.298 in.wg Brake horsepower curve Notes: All dimensions shown are in units of in. QmCQ *Please consult factory for actual motor amp draw LwA-A weighted sound power level,based on ANSI S1.4 Imp Sound Power by Octave Band dBA-A weighted sound pressure level,based on 11.5 dB Riga Sound 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones attenuation per Octave band at 5 ft-dBA levels are not SOVAD Data licensed by AMCA International Inlet 80 89 80 84 81 78 75 70 86 75 24 Sones-calculated using AMCA 301 at 5 ft Draroaz w�i non°norma % rusocimon "e, mTnnnnnnnm.Inc. v Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 2 of 21 •GREENHECK Printed Date: 09/20/2018 Job: StorQuest Tigard Building Value in Air. Mark: EF-1 Model: SE1-20-432-A15 Model: SE1 -20-432-A15 Sidewall Direct Drive Fan Standard Construction Features: -Fan panels of galvanized steel-Aluminum blade propeller-Die formed, galvanized steel drive frame assembly-Corrosion resistant fasteners Selected Options &Accessories: NEMA Premium Efficient Motor-meets NEMA Table 12-12 Motor with Thermal Overload UL/cUL 705 Listed-"Power Ventilators" Airflow Direction:Exhaust Damper Mounted,VCD-23-PB-22X22,Not Coated Damper Actuator, 115 VAC Actuated Long Wall Hsg,Flush Exterior,w/OSHA Grd. Motor Access:From Int.of Bldg. Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Weatherhood,Galvanized 45 deg.with Bird Screen Unit Warranty: 1 Yr(Standard) Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 3 of 21 01GREENHECK Printed Date: 09/20/2018 Job: StorQuest Tigard Buikling Value in Air. Mark: EF-1 Model: SE1-20-432-A15 Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1 1/2 hp Voltage: 208 UL Listed: Yes Manufacturer: Square D Cycle: 60 Amperage: 30 CSA Approved: Yes Overload Protection: None Phase: 3 Switch Pole(s): 3 Rating: 10 hp Junction Box Mtg.: Mounted and Wired RPM: 1750 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details a c Wiring Schematic 3.00 -Ff 4.25 1 3 0 • 0.56 t 275 — i 0.41 —1.63— O O O 2.88 - 2.44 m ■ Filsi ll ., Notes:All dimensions shown are in units of in. Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 4 of 21 Printed Date: 09/20/2018 LGREENHECK Job: StorQuest Tigard Building Value in Air. Mark: EF-1 Model: SE1-20-432-A15 Assembly Drawing Type: Sidewall Direct Drive Fan <. 38.00 24.75 I � � I u DRAWING VIEWED FROM INTERIOR •■O]• 26.25 29.25 1111Ili'' d 23.63 � r WEATHERHOOD 26.25 GUARD I I 29.25 WALL HOUSING I I DAMPER I INTERIOR J EXTERIOR END VIEW DIMENSIONS ARE FOR HOUSING NOT FAN PANEL WALL OPENING 27.25 SQ. MOTOR IS ACCESSIBLE FROM INTERIOR OF BUILDING EXHAUST AIRFLOW THIS IS AN EXHAUST FAN DUE TO MOTOR ORIENTATION THIS FAN HAS 4 BLADES Notes:All dimensions shown are in units of in.. Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 5 of 21 GREENHECK Printed Date: 09/20/2018 Job: StorQuest Tigard Building Value in Air. Mark: EF-1 Model: SE1-20-432-A15 Control Damper Model: VCD-23 Standard Construction Features: -Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications-Galvanized 16 ga channel frame-Galvanized blades with reinforcements-Side mounted steel linkage is concealed in the frame to prevent additional pressure drop -Axles are steel and 0.5 in. dia.-Synthetic axle bearings-Width and height furnished approximately 0.25 in. undersized - Field wiring is required to individual components Damper Configuration: Actuator Type: 115 VAC End Switch: No Actuator Configuration: Manufacturer: Belimo Jackshaft Quantity: 0 Model: TFB120 Mounting: Internal Quantity: 1 10.0 Min. 5.0 �1101 1 110 . 411 II 110°' 2211 22 1.3 = max. 1.3 max. DAMPER TYP. SECTION VIEW Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.25 in.undersize Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 6 of 21 , , Printed Date: 09/20/2018 JjGREENHECK Job: StorQuest Tigard Building Value in Air. Mark: EF-1 Model: SE1-20-432-A15 45 Degree Weatherhood Standard Construction Features: Galvanized Steel or aluminum construction. 0.5 welded wire birdscreen. Prepunched mounting holes. Field assembled. 24.75 — 22.5 - IP 23.625 • •�:���� SIDE VIEW ELEVATION VIEW Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 7 of 21 JGREENHECK Printed Date: 09/20/2018 Job: StorQuest Tigard Building Value in Air. Mark: EF-1 Model: SE1-20-432-A15 Long Wall Housing Standard Construction Features: - Galvanized steel construction - Heavy gauge mounting flanges - Pre-punched mounting holes - Inside flanges allow damper to be mounted - Overlapping weatherhood flange keeps rain out - OSHA Protective guard of welded steel wire completely protects the drive side of the wall housing. 38 NN26.25 'INNs0 �\► `\ 26.25 ININ % 1.5 Notes:All dimensions shown are in units of in. Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 8 of 21 Printed Date: 09/20/2018 GREENHECK Job: StorQuest Tigard Building Value in Air. Mark: EF-1 Model: SE1-20-432-A15 AMCA amca WORIDWIDE CERTIFIED RATIRGS SOND MID AIR PERFORMAACE RIR kid mOVERIERT nr)COfTROI •��c nssocInTlon IRTERRRTIORRI. inc. AMCA Licensed for Sound and Air Performance. Power rating(BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW)does not include transmission losses. Performance ratings do not include the effects of appurtenances(accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only. Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 9 of 21 ,GREENHECK Printed Date: 09/20/2018 Job: StorQuest Tigard Building Value in Air. Mark: EF-JR Model: SP-B90 --15.625y (14.875- Model: SP-B90 '� o__ i Ceiling Exhaust Fan S 0 _�4.5 E 13.25 Standard Construction Features: -Corrosion resistant galvanized steel scroll and housing-White designer non- - I — i yellowing grille-Round outlet duct collar with integral backdraft damper-Single inlet forward curved wheel-Plug type disconnect-Adjustable mounting brackets 1/4 in.threaded rod Selected Options &Accessories: (field provided) Motor with Thermal Overload Vibration Isolators Motor with CSA Approval (from manufacturer) 06 —11.5 Motor with 40 Degree C Ambient Temperature 13.875 t -. 1.25- Motor rated for continuous use �IMOUNTING UL/cUL 507 Listed-Electric Fan � BRACKET � 1 Solid State Speed Control,6 Amp,Shipped Loose ,, I 7 Round Hooded Wall Cap,(PN:WC-6)Shipped Loose JDesigner Grille Round Duct Connection Isolation Kit,(PN:VI KIT-SP/CSP),Shipped Loose Polypropylene Wheel Material Energy Star Rated Can Be Used to Comply with:ASHRAE 62.2,California Title 24,and Washington State Energy Code Dimensional Quantity 1 Weight w/o Acc's(Ib) 10 Weight w/Acc's(lb) 14 0.6 � Performance 0.5 ---.,890 Requested Volume(CFM) 50 '-''.F/Q�p Actual Volume(CFM) 50 M Total External SP(in.wg) 0.25 3 0.4 m co Fan RPM 590 C FLA(A) 0.65 2 0.3 a I ` Elevation(ft) 108 y co y' � Airstream Temp.(F) 70 m r ' I Air Density(Ib/ft3) 0.075 d 0.2 -- - Sones 1.0 ° • to 0 0.1 •c o s0e . o sl s. 0 10 20 30 40 50 60 70 80 90 Motor Volume(CFM) Motor Mounted Yes ( Operating point at Total External SP **Input Watts(W) 12 Fan curve Voltage/Cycle/Phase 115/60/1 System curve Enclosure ODP Notes: All dimensions shown are in units of in. Mica "FLA is approximate and will vary slightly with the motor. NORtDNIDE Sones-calculated using AMCA 301 at 5 ft OERTIfIED WHIGS **Wattage is approximate and may vary between motors. SQUAD D re nuo�ioAe 021001_ IRI V I 2;.,_,,,, CERTIFIED ==., Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 10 of 21 Printed Date: 09/20/2018 ,GREENHECK Job: StorQuest Tigard Building Value in Air. Mark: EF-JR Model: SP-B90 Round Duct Connector Model: RDC Standard Construction Features: -Constructed of Polypropylene - Replaces the square discharge duct connector and damper using the existing mounting holes Sheet Metal Screw#10x318 b Screw holes 1"06Ii 4,c, 01 r..„, •. 2 _.„„.... 1 • a \,..._.4„, : „ iii .. ..,,t_si„,,,,,„...... .\„...„. 6 Notes:All dimensions shown are in units of in. Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 11 of 21 GREENHECK Printed Date: 09/20/2018 Job: StorQuest Tigard Building Value in Air. Mark: EF-JR Model: SP-B90 Discharge Accessory Type: Wall Cap - Rnd Standard Construction Features: - Aluminum construction - Designed for outside wall application - Built in damper 8 6 8 5 4. 125 Notes:All dimensions shown are in units of in. Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 12 of 21 L GREENHECK Printed Date: 09/20/2018 Building Value Job: StorQuest Tigard 9 in Air. Mark: EF-JR Model: SP-B90 Isolation Kit Type: Hanging Standard Construction Features: - Neoprene vibration isolation for hanging installation - Kit includes four isolators and all hardware necessary for mounting one unit except for the 0.25 in. x 20 in. threaded rod to be supplied by others - Fan mounting brackets include prepunched mounting holes for ease of installation 1/4-20 1/4-20 Threaded Rod Ir B support 0,ing s (By others) r" l r others w.. 1/4-20 Zinc Plated Nut 'S— Zinc Plated Flat Washer e�e Shaft Sleeve Neoprene Grommet ce- k- "d Zinc Plated Flat Washer �■ 1/4-20 Zinc Plated Nut Unit Size A B Description Qty B50-6200 4 1/2(114) 15 5/8(397) Neoprene Grommets 4 A50-A190 5 1/2(140) 14 5/8(371) 1 x 32 Zinc Plated Nuts 8 A200-A390 6 3/4(171) 15 1/2 (394) Zinc Plated Flat Washers 8 A410,A510, A710, A780 9 1/4(235) 19 5/8(498) 3/8 x 3/16 Shaft Sleeves 4 A700 5 1/2(140) 25 1/8(638) A900-A1050, A1410 -A1550 9 1/4(235) 25 3/8(645) A1750, A2150 9 1/4(235) 36 3/4(933) A3600 9 1/4(235) 48 5/8(1235) All dimensions shown in inches (millimeters). Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 13 of 21 Printed Date: 09/20/2018 fGREENHEK Job: StorQuest Tigard Building Value in Air. Mark: EF-JR Model: SP-B90 SP-B90 Min/Max Fan Curve Performance Requested Actual Total External Fan Operating Volume Volume SP(in.wg) RPM Power(hp) (CFM) (CFM) 50 50 0.25 590 0.01 0.8 0.7 B . d 0.6 A •ii A ` '11 30.5 �9p Rp T. 0.4 hp I 12 0.3 420 . s — — v c�� 0.2 = I 0.1 0 20 40 60 80 100 120 Volume (CFM) O Operating point at Total External SP Fan curve System curve Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 14 of 21 L GREENHECK Printed Date: 09/20/2018 Job: StorQuest Tigard Building Value in Air. Mark: EF-JR Model: SP-B90 AMCA amca WORLDWIDE CERTIFIED RATIRGS SOWID MID AIR PERIORMAACE RIR Q� MOVERIERT ARD CORTROI *o"4c. RSSOCIflTIOfl '0,9 IflTERflflTiOflfll. Inc. AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM)shown is nominal. Performance is based on actual speed of test. The watt ratings shown are at free air. The sound ratings shown are for loudness values in spherical sones at 5 ft. (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: ducted outlet spherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. The AMCA licensed air and/or sound performance data has been modified for installation, appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the product. Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 15 of 21 . , Printed Date: 09/20/2018 ,GREENHECK Job: StorQuest Tigard Building Value in Air. Mark: EF-TR Model: SP-B110 f-15.625— —14.875-- Model: SP-6110 -4 --- Ceiling Exhaust Fan 4.5 13.25 Standard Construction Features: -Corrosion resistant galvanized steel scroll and housing-White designer non- , 1 yellowing grille-Round outlet duct collar with integral backdraft damper-Single inlet forward curved wheel-Plug type disconnect-Adjustable mounting brackets 1/4 in.threaded rod Selected Options &Accessories: (field provided) Motor with Thermal Overload Vibration Isolators Motor with CSA Approval (from manufacturer) 06 —11.5-a- --.-- Motor with 40 Degree C Ambient Temperature —13.875 I —1.25 Motor rated for continuous use MOUNTING UL/cUL 507 Listed-Electric Fan BRACKET W=Al I Solid State Speed Control,6 Amp,Shipped Loose MoA, �I 7 Round Hooded Wall Cap,(PN:WC-6)Shipped Loose Designer Grille Round Duct Connection Isolation Kit,(PN:VI KIT-SP/CSP),Shipped Loose Polypropylene Wheel Material Can Be Used to Comply with:ASHRAE 62.2 and Washington State Energy Code Dimensional Quantity 4 Weight w/o Acc's(Ib) 10 Weight w/Acc's(lb) 14 0.8 _794 Performance 0.7 illy:) Requested Volume(CFM) 801 0.6 Actual Volume(CFM) 80 Total External SP(in.wg) 0.25 3 0.5 t Fan RPM 794 C m *FLA(A) 1.14 2 0.4 — .__. — --- - a , Elevation(ft) 1081 rn Airstream Temp.(F) 70 2 0.3 h --____-- _.-- — o_ Air Density(Ib/ft3) 0.075 o •r i .16 Sones 0.9 coS 0.2 t� — 0.1 °` fi CP Syestem .-. 0.0 0 20 40 60 80 100 120 Motor Volume(CFM) Motor Mounted Yes 0 Operating point at Total External SP **Input Watts(W) 80 Fan curve - Voltage/Cycle/Phase 115/60/1 System curve Enclosure ODP Notes: All dimensions shown are in units of in. amca 'FLA is approximate and will vary slightly with the motor. OORIDEEIDE Sones-calculated using AMCA 301 at 5 ft ammo MIMI **Wattage is shown at free air. **Wattage is approximate and may vary between motors. SO11AD ® 21001- nin N V I o` No CERTIFIED ,ZR;r7:,n,,, Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 16 of 21 •GREENHECK Printed Date: 09/20/2018 Job: StorQuest Tigard Building Value in Air. Mark: EF-TR Model: SP-B110 Round Duct Connector Model: RDC Standard Construction Features: -Constructed of Polypropylene - Replaces the square discharge duct connector and damper using the existing mounting holes b.e.- Sheet Metal Screw#10x318 Screw hales N. tiii. 614) 4 4001 .il 4'9:111 011) -':'' • a• *. lilN100.. I li , „00/ 1. t i NIIIISN: _ .‘141M40•W Notes:All dimensions shown are in units of in. Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 17 of 21 Printed Date: 09/20/2018 GREENHECK Job: StorQuest Tigard Building Value in Air. Mark: EF-TR Model: SP-B110 Discharge Accessory Type: Wall Cap - Rnd Standard Construction Features: - Aluminum construction - Designed for outside wall application - Built in damper 8 6 1 s 8 5 4. 125 Notes:All dimensions shown are in units of in. Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 18 of 21 12iGREENHECK Printed Date: 09/20/2018 Job: StorQuest Tigard Building Value in Air. Mark: EF-TR Model: SP-B110 Isolation Kit Type: Hanging Standard Construction Features: - Neoprene vibration isolation for hanging installation - Kit includes four isolators and all hardware necessary for mounting one unit except for the 0.25 in. x 20 in. threaded rod to be supplied by others - Fan mounting brackets include prepunched mounting holes for ease of installation A'''*. 1/4-20 1/4-20 Threaded Rod I .-- Bsupporting ■ (By otheis) rothersd by 1/4-20 Zinc Plated Nut ---:, � ° o ''---- .4 Zinc Plated Flat Washer I >e Shaft Sleeve i '�. I Neoprene Grommet �'r Ili _ .- Zinc Plated Flat Washer g■ 1/4-20 Zinc Plated Nut Unit Size A B Description Qty B50-B200 4 1/2(114) 15 5/8 (397) Neoprene Grommets 4 A50-A190 5 1/2(140) 14 5/8(371) 1 x 32 Zinc Plated Nuts 8 A200-A390 6 3/4(171) 15 1/2 (394) Zinc Plated Flat Washers 8 A410,A510, A710,A780 9 1/4(235) 19 5/8(498) 3/8 x 3/16 Shaft Sleeves 4 A700 5 1/2(140) 25 1/8(638) A900 -A1050,A1410 -A1550 9 1/4(235) 25 3/8(645) A1750, A2150 9 1/4(235) 36 3/4(933) A3600 9 1/4(235) 48 5/8(1235) All dimensions shown in inches (millimeters). Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 19 of 21 121GREENFIECK Printed Date: 09/20/2018 Job: StorQuest Tigard Building Value in Air. Mark: EF-TR Model: SP-B110 SP-B110 Min/Max Fan Curve Performance Requested Actual Total External Fan Operating Volume Volume SP(in.wg) RPM Power(hp) (CFM) (CFM) 80 80 0.25 794 0.02 1 .2 Bhp@ Ma SRP - -- 0.9 , 794 FRPIVI 8h. I @ tiJ�n 20.6 ii.pM_ u) CL 570 FRpm ! U 0.0 _ - i 0 20 40 60 80 100 120 140 Volume (CFM) 0 Operating point at Total External SP Fan curve System curve Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 20 of 21 GREENHECK Printed Date: 09/20/2018 Job: StorQuest Tigard Building Value in Air. Mark: EF-TR Model: SP-B110 AMCA amca WORLDWIDE CERTIFIED RRTIRGS N/fsou:ii R PERF ORMAACE RIR Q� mOVEn1ERT w ARD CORTROI .%c nssOCInTiOn 47•o479 InTERnnTIOnf I. Inc. AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM)shown is nominal. Performance is based on actual speed of test. The watt ratings shown are at free air. The sound ratings shown are for loudness values in spherical sones at 5 ft. (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: ducted outlet spherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. The AMCA licensed air and/or sound performance data has been modified for installation, appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the product. Generated by:druby@johnsonair.com CAPS 4.27.1405 Y:\DannyRuby\StorQuest Tigard.gfcj Page 21 of 21