Report ac - � PORTLAND � `0 �'fCyniy MECHANICAL CONTRACTORS. INC. 4 "Committed to Quality" co'il R,AGAO‘S Heating Air Conditioning Refrigeration Plumbing • RECEIVED Submittal Data OCT - 1 2018 Unit Heaters BUILDING �����N Project: StorQuest Tigard - 12516 Submitted By: Portland Mechanical Construction, Inc. Attention: Paul Hettervig 2000 SE Hanna Harvester Dr Milwaukie, OR 97222 (503) 656-7400 Supplier: Johnson Air Products 2220 SE 9th Ave Portland, OR 97293 503-234-5071 Date Submitted: September 25, 2018 2000 SE Hanna Harvester Drive • Milwaukie, Oregon 97222 503/656-7400 • fax 503/655-0620 •toll free 866/656-7400 •www.pmc-g.com OR CCB# 151807 • WA#CCO1 PORTLMCO24KA• ID#HVCC1213 & PLBC12598 :bDINE AccuSpec V4.19 Transaction #: 10650318 JOB TITLE: StorQuest Date: 09/20/2018 Approved By: Submittal review and approval required prior to listed unit(s) being released for production and shipment. Unit(s)configured based on information provided. The Approver is responsible for ensuring the units,options,and accessories meet the job specifications. wii: DINE AccuSpec V4.19 SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: StorQuest Date: 09/20/2018 Location: Tigard, OR Engineer: Submitted by: Danny Ruby Architect: Contractor: Unit Tag UH-1 UH-2 Model Number PTC 55AS0111FBAN PTC 85AS0111FBAN Quantity of Units 17 3 Btu/Hr Input 55,000 85,000 Btu/Hr Output 51,150 79,050 CFM 1097 1650 Altitude 0-2000 0-2000 Temperature Rise (degrees F) 43 44 External Static Pressure (E.S.P) 0.00 0.00 Total Static Pressure (T.S.P.) 0.00 0.00 Gas Type _ Natural Natural — Gas Control Type Single Stage, Direct Single Stage, Direct Spark Ignition, Spark Ignition, 100% Shut-Off with 100% Shut-Off with Continuous Retry Continuous Retry Supply Voltage 115/60/1 115/60/1 Control Voltage 24V 24V Motor HP 1/8 1/8 Motor RPM 1625 1625 Blower RPM N/A N/A Heat Exchanger Type Aluminized Steel Aluminized Steel Heat Heat Exchanger/Burner Exchanger/Burner Options &Accessories (See Attached Pages) Remarks _ wili��DINE AccuSpec V4.19 SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Model Description Qty Tag PTC 55AS0111FBAN Propeller Unit Heater 17 UH-1 66907 PTC 55AS0111FBAN 17 63174 Thermostat, White Rogers 1C26-101, 50-90°F 17 57873 Recharge Kit for pH Neutralizing Kit 17 PTC 85AS0111FBAN Propeller Unit Heater 3 UH-2 65795 PTC 85AS0111FBAN 3 63174 Thermostat, White Rogers 1C26-101, 50-90°F 3 _ 57873 Recharge Kit for pH Neutralizing Kit 3 �IVIODINE TAG: UH-1 AccuSpec V4.19 PTC MODEL NOMENCLATURE 1,2,3 4,5,6 7 8 9,10 11,12 13 14 15 16 PTC 55 A 5 01 J 11 F B A N 1,2,3 - Product Type PTC - Separated Combustion, High Efficiency Condensing Propeller Unit 4,5,6 - Furnace Input Rating 55 - 55,000 7 - Heat Exchanger Type A-Aluminized Steel Heat Exchanger and Burner 8 - Pilot Ignition S- Direct Spark Ignition 9,10-Motor and Drive Code (Power Code) 01 - 115V motor 11,12-Gas and Valve/Ignition Control Type (Control Code) 11 - Natural, Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 13-Fan Guard Type F - Finger Proof Fan Guard 14-Development Sequence B - Current 15-Future A- For Future Use 16-Factory Installed Option N - None '3DINE TAG: UH 1 AccuSpec V4.19 GENERAL PERFORMANCE DATA c us tiarso Intertek General Performance Data Model PTC 55 At 0' Elevation Btu/Hr. Input 55,000 Btu/Hr. Output 51,150 Entering Airflow (CFM) 1097 Outlet Velocity 618 Air Temp. Rise (°F) 43 Mounting Height (Max Ft.)1 12 Heat Throw (Max. Mtg. Ft.)2 43 Unit Total Power (Amps) 4.35 Condensate Produced (gal/hr) 0.3 As Configured at 0-2000 Ft. Elevation Btu/Hr. Input 55,000 Btu/Hr. Output 51,150 Configured Air Temp Rise (°F) 43 Motor Data Horse Power 1/8 RPM 1625 Type P.S.C. Motor Amps at 115V 2.20 Clearances to Combustibles Top and Bottom 6" Vent/Combustion Air Connector 6" Access Side 6" Non-Access Side 6" Rear 18" 1 At 65°F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit. 2 Heat Throws are calculated at 65°F ambient with a 43°F air temperature rise with the unit mounted at a maximum mounting height of 12 feet. TAG: UH-1 J ?ODINE AccuSpec V4.19 DIMENSIONS - UNIT Model PTC Dimensions KNOCKOUTS FOR SUPPLY POWER WIRING CONDUIT ENTRANCE ADJUSTABLE 0(MINIMUM DISTANCE TO WALL) ---- �,.. A LOUVERS 3S61 14.90-- (4)318"-16 MTG HOLES N P -1 It ! '^ '' 1 ,-ACCESS - .,,,,f = PANEL �_ t(r'''' f >� COMBUSTION /^AIR INLET (OPENING) Igit 1111VtrIT-StrET I �mRz '"". : '7 /CONN. L . 7i- `� T K ill - C FAN CONDENSATE DRAIN - l .- F i-I 3/4'PVC ;- G . R (APPROX.) - D (OPENING) - -- H Model Size PTC55 Dimensions (inches) A 29.8 J 12.81 B 18.13 K 6 C 19.03 L 9.07 D 17 M 3.3 E 16.24 N 1.9 i F 4.71 P 16 G 7.19 Q2 40.19 H 10.22 R 28.19 I 3.1 Gas Connection 1/2 Fan Diameter 14 - ' Vent Pipe Connection Size 3 Combustion Air Inlet Pipe Connection Size 3 Approx. Shipping Weight 93 lbs. 1 All models have 4 holes for mounting. Listed is the hole diameter and threads per inch to accept threaded rod. 2 Dimension equals overall "R" dimension plus 12". TAG: UH-1 Standards All unit(s)shall include: ETL design certification for use in both the US and Canada to the ANSI Z83.8 - latest revision, standard for"Gas Unit Heater and Gas-Fired Duct Furnaces" for safe operation, construction, and performance Mechanical Configuration Condensing furnace section with 93% minimum efficiency provided by an indirect-fired tubular heat exchanger with individually fired tubes coupled to a secondary recuperative heat exchanger for maximum heat recovery. Venting/Combustion Air Arrangement The unit shall be separated combustion. The venting shall be a power exhausted arrangement with a separate combustion air intake pipe connection to allow for fresh combustion air from outside the conditioned space. The unit shall be tested to insure proper ignition when the unit is subjected to 40 mile per hour wind velocities. The unit shall also include a factory mounted differential pressure switch designed to prevent main burner ignition until positive venting has been proven. Venting shall be Schedule 40 PVC. For Canadian installations, all vent pipe and components must be approved to ULC S636. Unit Casing The unit heater(s) casing shall be constructed of not less than 20 gauge aluminized steel with minimization of exposed fasteners. All exterior casing parts shall be cleaned of all oils and a phosphate coating applied prior to painting. The exterior casing parts shall then be painted with an electrostatically applied baked-on gray-green polyester powder paint (7-mil thickness) for corrosion resistance. The unit shall be furnished with horizontal air deflectors. The deflectors are adjustable to provide for horizontal directional airflow control (up or down). Furnace Section The heat exchanger(s) shall be made of 18 gauge aluminized steel tubes and headers. Each heat exchanger tube shall be individually and directly flame-fired. The heat exchanger tube shall be crimped to allow for thermal expansion and contraction. The flue collector box shall be made of 20 gauge AL29-4C stainless steel. The thermal efficiency of the unit(s) shall be a minimum of 93% efficient for all air flow ranges through the use of a secondary recuperative heat exchanger. The secondary heat exchanger shall be constructed of AL29-4C stainless steel to withstand the corrosive environment of condensing gas fired equipment. The heat exchanger(s) seams and duct connections shall be certified to withstand 0.9" W.C. external static pressure without burner flame disturbance. The burner(s) shall be in-shot type, directly firing each heat exchanger tube individually and is designed for good lighting characteristics without noise of extinction for both natural and propane gas. The ignition controller(s) shall be 100% shut-off with continuous retry. TAG: UH-1 The gas pressure shall be between 6-7" W.0 for natural gas. The solid state ignition system shall directly light the gas by means of a direct spark igniter each time the system is energized. The unit gas controls shall be provided with the following: Single-stage gas controls with a single-stage combination gas control, an ignition control. The unit fires at 100%full fire based on a call for heat from a room thermostat. An automatic reset high limit switch mounted in the air stream to shut off the gas supply in the event of overheating. An automatic reset high limit switch mounted on the power exhauster housing to shut off the gas supply in the event of overheating flue gas temperatures. A condensate drain line overflow switch that senses if the condensate line is clogged and shuts the unit heater down. The switch is factory mounted inside the unit cabinet and wired to the unit controls. An energy-saver control utilizes stratified ceiling air to heat the space at floor level before turning on the gas controls. Its operation is independent of the room thermostat and should have a higher set-point than the room thermostat.The Stat is factory mounted outside the unit and wired into the contractor convenience box. A Modine Building Management System (BMS) Board installed in this unit provides an RS485 interface between the unit heater and existing building networks that employ a BACnet or Modbus protocol.The board works in conjunction with the unit's ignition control module to manage and report the function of the heater. A BMS network connection is not required to operate the heater, but allows for expanded control and monitoring ability. A time delay relay that delays the start of the air mover to allow the heat exchanger a warm-up period after a call for heat.The time delay relay shall also continue the air mover operation after the thermostat has been satisfied to remove any residual heat in the heat exchanger. The unit shall be orificed for 0-2000 feet elevation above sea level. Electrical All electrical components shall carry UL, ETL, or CSA certification. A low voltage terminal board shall be provided for direct wiring connection to an external thermostat. A Contractor Convenience Package that consists of an external junction box featuring simple connection of supply power wiring internally, thermostat wiring to terminals eternally, an On/Off switch, a single 115V outlet for connection of an external condensate pump, and status indicator lights to display the operational state of the unit shall be factory mounted on the rear panel of the casing. A single 115V to 24V step down transformer shall be provided for all unit controls. Air Mover The motor horsepower shall be 1/8 H.P. The motor wiring shall be in flexible metal BX conduit. TAG: UH1 The motor shall be controlled by a time delay relay. Propeller models shall meet the following requirements: The motor type shall be Single-Speed, Totally Enclosed (TE). The air mover motor shall be a 115V motor. Mounting The unit shall be equipped with tapped holes to accept 3/8"-16 threaded rod for suspension. Accessories The following field installed accessory control devices shall be provided with the unit: A recharge kit for pH neutralizing kit (Item Code 57872). Includes sufficient aggregate for a complete recharge of the neutralizing kit. A condensate drain kit consisting of one threaded PVC elbow and two specially designed condensate traps to allow the unit to operate and drain properly. TAG: UH-2 �DiINE AccuSpec V4.19 PTC MODEL NOMENCLATURE 1,2,3 4,5,6 7 8 9,10 11,12 13 14 15 16 FTC 85 A S 01 11 F B A N_j 1,2,3 - Product Type PTC- Separated Combustion, High Efficiency Condensing Propeller Unit 4,5,6 - Furnace Input Rating 85 - 85,000 7 - Heat Exchanger Type A- Aluminized Steel Heat Exchanger and Burner 8 - Pilot Ignition S- Direct Spark Ignition 9,10- Motor and Drive Code (Power Code) 01 - 115V motor 11,12-Gas and Valve/Ignition Control Type(Control Code) 11 - Natural, Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 13 -Fan Guard Type F - Finger Proof Fan Guard 14-Development Sequence B - Current 15 -Future A- For Future Use 16-Factory Installed Option N - None 403DINE TAG: UH-2 AccuSpec V4.19 GENERAL PERFORMANCE DATA c us Intertek General Performance Data Model PTC 85 At 0' Elevation Btu/Hr. Input 85,000 Btu/Hr. Output 79,050 Entering Airflow (CFM) 1650 Outlet Velocity 619 Air Temp. Rise (°F) 44 Mounting Height (Max Ft.)1 13 Heat Throw (Max. Mtg. Ft.)2 48 Unit Total Power (Amps) 4.35 Condensate Produced (gal/hr) 0.5 As Configured at 0-2000 Ft. Elevation Btu/Hr. Input 85,000 Btu/Hr. Output 79,050 Configured Air Temp Rise (°F) 44 Motor Data Horse Power 1/8 RPM 1625 Type P.S.C. Motor Amps at 115V 2.20 Clearances to Combustibles Top and Bottom 6" Vent/Combustion Air Connector 6" Access Side 6" Non-Access Side 6" Rear 18" At 65°F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit. 2 Heat Throws are calculated at 65°F ambient with a 44°F air temperature rise with the unit mounted at a maximum mounting height of 13 feet. �����90D1NE TAC; UH-2 AccuSpec V4.19 DIMENSIONS - UNIT Model PTC Dimensions KNOCKOUTS FOR SUPPLY POWER WIRING CONDUIT ENTRANCE ADJUSTABLE 0(MINIMUM DISTANCE TO WALL) -A- ' I i LOUVERS 9.Sfit--14.90-- (4)318"-16 MTG HOLES �`N P 1' D 7-ACCESS PANEL r fl: I ip,,,,. ..• _.... ,.._m . f 1 f$ CE COMBSTIN ,! -AIR INET24: B VEwT'.. ij`f - ONNr L P , 1 ! ( C „] FAN-- CONDENSATE DRAIN -1 F F- 1 3/4"PVC ( G .. R (APPROX.) -. D (OPENING) - I--H----? Model Size PTC85 Dimensions (inches) _ A 35.53 J 6.73 B 20.31 K 8.74 C 22.05 L 12.13 D 22.52 M 3.86 E 18.42 N 1.54 F 4.50 P 22.03 G 7.98 Q2 45.83 H 10.27 R 30.69 1.32 Gas Connection 1/2 __ Fan Diameter —18 Vent Pipe Connection Size 3 Combustion Air Inlet Pipe Connection Size 3 Approx. Shipping Weight 125 lbs. 1 All models have 4 holes for mounting. Listed is the hole diameter and threads per inch to accept threaded rod. 2 Dimension equals overall "R" dimension plus 12". Standards TAG: UH-2 All unit(s)shall include: ETL design certification for use in both the US and Canada to the ANSI Z83.8 - latest revision, standard for "Gas Unit Heater and Gas-Fired Duct Furnaces" for safe operation, construction, and performance Mechanical Configuration Condensing furnace section with 93% minimum efficiency provided by an indirect-fired tubular heat exchanger with individually fired tubes coupled to a secondary recuperative heat exchanger for maximum heat recovery. Venting/Combustion Air Arrangement The unit shall be separated combustion. The venting shall be a power exhausted arrangement with a separate combustion air intake pipe connection to allow for fresh combustion air from outside the conditioned space.The unit shall be tested to insure proper ignition when the unit is subjected to 40 mile per hour wind velocities. The unit shall also include a factory mounted differential pressure switch designed to prevent main burner ignition until positive venting has been proven. Venting shall be Schedule 40 PVC. For Canadian installations, all vent pipe and components must be approved to ULC S636. Unit Casing The unit heater(s) casing shall be constructed of not less than 20 gauge aluminized steel with minimization of exposed fasteners. All exterior casing parts shall be cleaned of all oils and a phosphate coating applied prior to painting. The exterior casing parts shall then be painted with an electrostatically applied baked-on gray-green polyester powder paint (7-mil thickness) for corrosion resistance. The unit shall be furnished with horizontal air deflectors. The deflectors are adjustable to provide for horizontal directional airflow control (up or down). Furnace Section The heat exchanger(s) shall be made of 18 gauge aluminized steel tubes and headers. Each heat exchanger tube shall be individually and directly flame-fired. The heat exchanger tube shall be crimped to allow for thermal expansion and contraction. The flue collector box shall be made of 20 gauge AL29-4C stainless steel. The thermal efficiency of the unit(s) shall be a minimum of 93% efficient for all air flow ranges through the use of a secondary recuperative heat exchanger. The secondary heat exchanger shall be constructed of AL29-4C stainless steel to withstand the corrosive environment of condensing gas fired equipment. The heat exchanger(s) seams and duct connections shall be certified to withstand 0.9" W.C. external static pressure without burner flame disturbance. The burner(s) shall be in-shot type, directly firing each heat exchanger tube individually and is designed for good lighting characteristics without noise of extinction for both natural and propane gas. The ignition controller(s) shall be 100% shut-off with continuous retry. TAG: UH-2 The gas pressure shall be between 6-7" W.0 for natural gas. The solid state ignition system shall directly light the gas by means of a direct spark igniter each time the system is energized. The unit gas controls shall be provided with the following: Single-stage gas controls with a single-stage combination gas control, an ignition control. The unit fires at 100% full fire based on a call for heat from a room thermostat. An automatic reset high limit switch mounted in the air stream to shut off the gas supply in the event of overheating. An automatic reset high limit switch mounted on the power exhauster housing to shut off the gas supply in the event of overheating flue gas temperatures. A condensate drain line overflow switch that senses if the condensate line is clogged and shuts the unit heater down. The switch is factory mounted inside the unit cabinet and wired to the unit controls. An energy-saver control utilizes stratified ceiling air to heat the space at floor level before turning on the gas controls. Its operation is independent of the room thermostat and should have a higher set-point than the room thermostat. The Stat is factory mounted outside the unit and wired into the contractor convenience box. A Modine Building Management System (BMS) Board installed in this unit provides an RS485 interface between the unit heater and existing building networks that employ a BACnet or Modbus protocol.The board works in conjunction with the unit's ignition control module to manage and report the function of the heater. A BMS network connection is not required to operate the heater, but allows for expanded control and monitoring ability. A time delay relay that delays the start of the air mover to allow the heat exchanger a warm-up period after a call for heat.The time delay relay shall also continue the air mover operation after the thermostat has been satisfied to remove any residual heat in the heat exchanger. The unit shall be orificed for 0-2000 feet elevation above sea level. Electrical All electrical components shall carry UL, ETL, or CSA certification. A low voltage terminal board shall be provided for direct wiring connection to an external thermostat. A Contractor Convenience Package that consists of an external junction box featuring simple connection of supply power wiring internally, thermostat wiring to terminals eternally, an On/Off switch, a single 115V outlet for connection of an external condensate pump, and status indicator lights to display the operational state of the unit shall be factory mounted on the rear panel of the casing. A single 115V to 24V step down transformer shall be provided for all unit controls. Air Mover The motor horsepower shall be 1/8 H.P. The motor wiring shall be in flexible metal BX conduit. TAG: UH-2 The motor shall be controlled by a time delay relay. Propeller models shall meet the following requirements: The motor type shall be Single-Speed, Totally Enclosed (TE). The air mover motor shall be a 115V motor. Mounting The unit shall be equipped with tapped holes to accept 3/8"-16 threaded rod for suspension. Accessories The following field installed accessory control devices shall be provided with the unit: A recharge kit for pH neutralizing kit (Item Code 57872). Includes sufficient aggregate for a complete recharge of the neutralizing kit. A condensate drain kit consisting of one threaded PVC elbow and two specially designed condensate traps to allow the unit to operate and drain properly.