Report (150) rcvEc_.acA-
lag s Rckc c 2_v-v
Setif"Melieosim uttdant,
LII /RE
X1471110+IIIR CDMO/71O NI11t
SUBMITTAL DATA RECEIVED
For: Approval
OCT - 1 2018
Order#: Date: 09/26/2018 CITY OF TIGARD
Project: StorQuest - Tigard BUILDING DIVISION
Project#:
Location: Tigard, OR.
Purchaser: PMC
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018
Date
09/26/2018
Project Name Serrm*ThrAwfamsui rSrandu,r/.
StorQuest-Tigard LU � E
Project Number �,.,,kb•A,.CnMa,r,aHVI.4
Client/Purchaser
PMC
Submittal Summary Page
Qty Tag# Model# Description
1 CU-1 TCD48B31 S Luxaire Brand, 4 Ton, Air Conditioner, R-410A Refrigerant, 13 SEER
/ 1-Stage, 208/230-3-60
1 F-1 TM9E100C2OMP11 Mid Tier, 95%AFUE, Single Stage Gas Valve, X13 ECM Motor, 100
MBH, 21"Width Cabinet, 2000 CFM Nominal, Multi-Position, 115-1-
60
1 C-1 CM48CBBA1 4 Ton, Mult-Position Cased, Coil, 21"Cabinet Width, Factory
Installed TXV Coils, Aluminum Tube
1 S1-THXU280W Wi-Fi Communicating Touchscreen Thermostat with Proprietary
Hexagon Interface (White)
1 S1-1BR0521 Bottom Return Filter Rack Galvanized (Fits 21"wide furnace)
1 S1-1CT0303 Concentric Vent Termination Kit-3"
Equipment start-up and commissioning by a factory trained technician is recommended.
Contact your supplying distributor or sales representative for additional information &guidance.
WARNING:Cancer and Reproductive Harm-www.P65Warnings.ca.gov
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018
The u LX Series Page:3
LIIXAIRE 13 SEER
A!/!IIID DII LDMDIIIDDIDD
Project Name: StorQuest-Tigard Unit Model#: TCD48B31S
Quantity: 1 Tag#:CU-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1
Cooling Performance , :,,, .....
Total gross capacity 47.5 MBH
Sensible gross capacity 35.3 MBH 1UXAIRE
Seasonal Efficiency(at ARI) 14.75 SEER •
Efficiency(at ARI) 12.50 EER '.
Ambient DB temp. 95.0 °F A,
Power input 3.81 kW {
Refrigerant ,
a� ':
Refrigerant type R-410A
Electrical Data
Power supply 208/230-3-60 y
Unit min circuit ampacity 18.4 Amps ;.
Unit max over-current protection 30 Amps ='_-
Dimensions&Weight >.
Hgt 37 in. Len 37 in. Wth 34 in.
Weight with factory installed options 200 lbs.
Matchup Information _ _ 4 Ton
ARI Reference Number 9734087
ARI Rated Capacity 47 MBH
.40,RI Rated Efficiency 14.75 SEER J Product Features
Note: Please refer to the tech guide for listed maximum static pressures • The TCD models are the latest iteration in our successful LX Series split
MEI
r system air conditioner lineup.Optimized for the 3 phase 13 SEER National
A
AMERICAN Minimum Efficiency,these outdoor units are specifically designed to be
r+� CERTIFIED.nuaurr �s matched with Luxaire indoor coils,furnaces,and air handlers to provide a
° �c use" complete system solution.
Unit Features
• 13 SEER/1-Stage
• Environmentally Friendly-CFC-free R-410A refrigerant delivers
environmentally friendly performance with zero ozone depletion.
• Durable Finish—A high quality powder paint finish rated at 1000 hrs.salt
spray provides the ultimate protection from corrosion and harmful UV rays,
ensuring a long-lasting,high quality appearance.
• Fully Exposed Refrigerant Connections and a Single Panel Covering the
Electrical Controls Make for Easy Servicing of the Unit
Warranty
• Standard One(1)-Year Limited Parts
• Standard Five(5)-Years Limited Compressor
•
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018
Ihr'm Standalrf. LX Series Page:4
IUXA/RE 13 SEER
Project Name: StorQuest-Tigard Unit Model#: TCD48B31S
Quantity: 1 Tag#:CU-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1
Factory Installed Options
TCD48B31S
Equipment Options Option(s) Selected
Product Category: T Luxaire Brand
Type: C Air Conditioner
Nominal Series Efficiency&Staging: D 13 SEER/1-Stage
Nominal Cooling Capacity: 48 4 Ton
Refrigerant: B R-410A Refrigerant
Voltage: 3 208/230-3-60
Product Generation: 1
Factory-Installed Options: S
Field Installed Accessories
S1-THXU280W-Wi-Fi
Communicating Touchscreen
Thermostat with Proprietary
Hexagon Interface(White) (1.0
lbs)
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018
Salm 7Ar/Y.%rmwtt Sandler'. LX Series Page:5
LUXA/RE 13 SEER
MfAlglf.Aw eo�unas/As
Project Name: StorQuest-Tigard Unit Model#: TCD48B31S
Quantity: 1 Tag#:CU-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1
TCD Typical Installation
TYPICAL INSTALLATION
A CAUTION: Special care must be taken to avoid recirculation of discharge air through condenser coil. NOTE:
48"OVERHEAD CLEARANCE \� asure adequate
� wwall support.
NEC CLASS 1 WIRING '. ate 1
kill WEATHERPROOF THERMOSTATS%SS �!/
DISCONNECT
SWITCH �'�I � �..-10•St...I ,
NEC CLASS 2 WIRING ..'I I��.
I
3 BRACES �-+ J
Use for wall mount with \ S'
center brace under
SNIcenter of compressor. "�►�1 AI FURNACE OR \�� AIR HANDLER
/ \ TERMINAL BLOCK
/ \� NEC CLASS 2 WIRING ��...,,
i
...,
., ..
10"CLEARANCE
��� ► A
`�"� ki \�AROUND PERIMETER . 0 �/�
il.
(6"clearance .� /► �4) 10,
permissible on one +� �� 'IL' i►..
side only,see `��;� ���� All outdoor wiring M `�r
Alternative y `% must be weatherproof. .0 �' 1.
Installation `�� I''� � �> ��
Clearances.) N 5 �.'' /
NOTE: CONTROL SEAL OPENINGS 5 SNOW PUMP-UPS
Ensure a minimum of ACCESS Use in deep snow areas
PANEL Use permagum or equivalent. with fifth pump-up under
24'clearance between
any two units. MINIMUM 18"SERVICE ACCESS CLEARANCE center of compressor.
Maintain minimum clearance on one side of access panel. A0200002
A CAUTION
Care must be taken to prevent ice from damaging the unit.Damage may occur from ice falling onto unit from a sloped roof or from a vertical drip
line due to a partial overhang.
NO OVERHANG COVERING UNIT OVERHANG COMPLETELY
\ COVERING UNIT OVERHANG PARTIALLY
\ COVERING UNIT
1
--— 48"MINIMUM
OVERHEAD
CLEARANCE
or t -- ,,
,. r
E
- r
} r
: i�, z --
Et= -1 " r T
INSTALLATION ACCEPTABLE INSTALLATION ACCEPTABLE INSTALLATION NOT RECOMMENDED
(Refer to CAUTION above.) (Refer to CAUTION above.)
NOTE: NOTE:
The unit must be installed on a solid base above the grade. Install unit on flat surface.If installation surface is sloped,ensure
The base must not be able to settle or shift causing strain on that unit slopes away from house structure at 114"per foot.
refrigerant lines and possible leaks.
A CAUTION:Special care must be taken to avoid recirculation of discharge air through condenser coil. A0291.01
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018
seraeg rnr w.weDwx.srrww. LX Series Page:6
IUXAIRE 13 SEER
tArfO1•API COND,lIONIID
Project Name: StorQuest-Tigard Unit Model#: TCD48B31S
Quantity: 1 Tag#:CU-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1
TCD Physical&Electrical Gen2
PHYSICAL AND ELECTRICAL DATA
MODEL TCD30 TCD36 TCD42 TCD48 TCD60 TCD30 TCD36 TCD42 TCD48 TCD60 TCD36 TCD48 TCD60
B32S B32S B32S B31SS B31SS B42S B42S B42S B41SS B41SS B52S B51SS B51SS
Unit Supply Voltage 208-230V,30,60Hz 460V,30,60Hz 575V,30,60Hz
Normal Voltage Range 1 187 to 252 432 to 504 540 to 630
Minimum Circuit Ampacity 11.91 14.34 15.29 18.4 21.2 5.67 7.85 7.68 8.4 10.3 5.30 6.6 7.7
Max.Overcurrent Device Amps 2 20 20 25 30 35 15 15 15 15 15 15 15 15
Min.Overcurrent Device Amps 3 15 15 20 20 25 15 15 15 15 15 15 15 15
Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
Compressor Rated Load 8.89 10.43 11.19 13.7 15.9 4.22 5.76 5.63 6.2 7.7 3.77 4.8 5.7
Locked Rotor 58.0 73.0 84.0 83.1 110.0 38.0 38.0 44.0 41.0 52.0 36.5 33.0 38.9
Crankcase Heater No No No No No No No No No No No No No
Factory External Discharge Muffler No No Yes No No No No Yes No No No No No
Fan Diameter Inches 22 22 24 24 26 22 22 24 24 26 22 24 26
Rated HP 1/8 1/4 1/4 1/4 1/4 1/8 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Rated Load Amps 0.80 1.3 1.3 1.30 1.30 0.40 0.65 0.65 0.65 0.65 0.58 0.58 0.58
Fan Motor Nominal RPM 1075 850 850 850 850 1075 850 850 850 850 850 850 850
Nominal CFM 2950 3275 3550 3500 4300 2850 3200 3650 3650 4075 3300 3550 4125
Face Area Sq.Ft. 13.83 17.37 18.74 18.74 23.40 13.83 17.37 18.74 18.74 23.40 17.37 18.74 23.40
Coil Rows Deep 1 1 1 1 1 1 1 1 1 1 1 1 1
Fins/Inch 23 23 23 23 23 23 23 23 23 23 23 23 23
Liquid Line Set OD(Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Vapor Line Set OD(Field Installed)4 3/4 3/4 7/8 7/8 1-1/8$ 3/4 3/4 7/8 7/8 1-1/81 3/4 7/8 1-18$
Unit Charge(Lbs.-Oz.)5 3-15 4-10 4-15 4-15 5-12 3-15 4-10 4-15 4-15 5-12 4-10 4-15 5-12
Charge Per Foot,Oz. 0.62 0.62 0.67 0.67 0.75 0.62 0.62 0.67 0.67 0.75 0.62 0.67 0.75
Operating Weight Lbs. 140 160 200 200 205 140 160 200 200 205 160 200 205
1. Rated in accordance with AHRI Standard 110-2012,utilization range W.
2. Dual element fuses or HACR circuit breaker.Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker.Minimum recommended overcurrent protection.
4. For applications with non-standard vapor line sizes,see the'Applications 8 Accessories"section of this Technical Guide.
5. The Unit Charge is correct for the outdoor unit,smallest matched indoor unit,and 15 feet of refrigerant tubing.For tubing lengths other than 15 feet,add or subtract
the amount of refrigerant,using the difference in actual lineset length(not the equivalent length)multiplied by the per foot value.
DIMENSIONS
Unit Dimensions Refrigerant Connection
Model (Inches) Service Valve Size
A B C Liquid Vapor
TCD30B(3,4)2S 30 29-1/4 29-1/4 34
TCD36B(3,4,5)2S 36-1/4 29-1/4 29-1/4
_ TCD42B(3,4)2S 33-1/4 35-1/4 31-3/4 3/8 7/8
TCD48B(3,4,5)1S 33-1/4 35-1/4 31-3/4I
A
TCD60B(3,4,5)1S 36-1/4 38 34-1/4 7/8$
I Adapter fitting must be field installed for the required 1-1/8"line set.
All dimensions are in inches and are subject to change without notice.
Overall height is from bottom of base pan to top of fan guard.
Overall length and width include screw heads.
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018
&WigIke R, ...tA ,,. Luxaire Page:7
LURA/RE. Single Stage ECM Multi-Position Gas Furnace
NFA)IN•s,�1N::L•NNYIId•tXd
Project Name: StorQuest-Tigard Unit Model#: TM9E100C2OMP11
Quantity: 1 Tag#:F-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1
C_ Cooling Performance
Total gross capacity 47.5 MBH
Sensible gross capacity 35.3 MBH ,. ,e.
Entering DB temp. 80.0 °F = N
Entering WB temp. 67.0 °F
Leaving DB temp. 61.3 °F -#„ '
Leaving WB temp. 58.5 °F
Heating Performance
Entering DB temp. 60 °F It
Heating output capacity(Max) 95 MBH �4 ;, .
Supply air 1750 CFM A} - I
Heating input capacity(Max) 100 MBH C
Leaving DB temp. 110.3 °F 11
Air temp.rise 50.3 °F
AFUE 95.0 %
Supply Air Blower Performance
Supply air 1750 CFM
Ext.static pressure 0.88 IWG Unit Features
Blower speed description HIGH
Motor rating 0.75 HP • Unit Cabinet Constructed of Pre-Painted Steel
Elevation 0 ft. • Sharp Edges Have Been Eliminated by Folding and Flattening the Sheet
Drive type DIRECT Metal
Indoor Electrical Data • Full-Gasket,Rigid Independent Access Doors With View Ports and 1/4 Turn
Power supply 115-1-60 Knobs
Unit min circuit ampacity 10.90 Amps • Units are factory shipped for installation in upflow or horizontal applications
Unit max over-current protection 15 Amps and may be converted for downflow applications.
Indoor Dimensions&Weight • Hi-tech Tubular Aluminized Steel Primary Heat Exchanger with Stainless
Hgt 33 in. Len 29.5 in. Wth 21 in. Steel Tube/Aluminum Fin Secondary Heat Exchanger for Outstanding
Weight with factory installed options 145 lbs. Efficiency.
Matchup Information • Propane Convertible
ARI Reference Number 9734087 • Slide-Out Direct Drive Blower with High Efficiency Brushless DC Motor
ARI Rated Capacity 47 MBH • Airflow Leakage Rate of Less Than 1%of Total Airflow @ 1"ESP Under
SRI Rated Efficiency 14.75 SEER) Duct Testing Conditions
Note: Please refer to the tech guide for listed maximum static pressures • Built-In,High-Level Self-Diagnostic Controls with Fault Codes for Reliable
®(v Operation
MPS �- AMEi1CAN
CERTIFIED- .�r ---.�. nu..am, ,..,„ Warranty
"'"""°"°""° �I • Five(5)Year Limited Parts Warranty
• A 20-year limited warranty on heat exchangers in residential applications.
• A 10-year warranty on heat exchangers in commercial applications.
• Extended lifetime heat exchanger and 10-year limited parts warranty when
product is registered online within 90 days of purchase for replacement or
closing for new home construction.
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018
Sating Perlitmanre Luxaire Page:8
LURA/RE Single Stage ECM Multi-Position Gas Furnace
Project Name: StorQuest-Tigard Unit Model#: TM9E100C2OMP11
Quantity: 1 Tag#:F-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1
Factory Installed Options
TM9E100C2OMP11
Equipment Options Option(s) Selected
Brand: T
Tier: M Mid Tier
Efficiency: 9 95%AFUE
Type: E Single Stage Gas Valve,X13 ECM Motor
BTU Input: 100 100 MBH
Cabinet Width: C 21"Width Cabinet
Airflow: 20 2000 CFM Nominal
Configuration: MP Multi-Position
Voltage: 1 115-1-60
Product Generation: 1
Field Installed Accessories
• S1-1BR0521 - Bottom Return
Filter Rack Galvanized (Fits 21"
wide furnace) (10.0 lbs)
• S1-1 CT0303-Concentric Vent
Termination Kit-3" (9.0 lbs)
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018
N
setting"y'«/ pu"c/,. Luxaire Page:9
L�1�f/I/)•L" Single Stage ECM Multi-Position Gas Furnace
I!A!/All�A/1 t1Ml/II11YIk1
Project Name: StorQuest-Tigard Unit Model#: TM9E100C2OMP11
Quantity: 1 Tag#:F-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1
Dimensions&Clearances
LEFT SIDE FRONT RIGHT SIDE
Combustion Air Inlet dr Combustion Air Inlet
S
•• Condensate Drain' Gas Pipe ! '
(Downflow) ��Entry Gas Pipe Condensate Drain •
Entry (Downflow)
—
Vent Outlet 10 Electrical
p�'��Entry Electrical —
Condensate o
Entry Vent Outlet
Drain , m m . 33 Condensate --k.►o 23"
r 1 m Drainr -1 t
0 D 11 Thermostat o
Wiring ; Thermostat fl 'O
Wiring Optional Return Air
Cutout(Either side) 14'
•
28.5"
►I�29.5" —* A—i{ 1.s"-01 I41 T
56"
�Ii 23.8" 3"
4) ��.1II VentDI-7
Outlet
g Combustion g
Air Inlet C
1
.56„-01-.56” 20" ----------
Fill 24.25" 01
SUPPLY END RETURN END
Cabinet&Duct Dimensions
BTUH(kW) Nominal Cabinet Cabinet Dimensions(Inches) Approximate
Operating Weights
Input CFM(m3/min) Size
A B C Lbs
TM9E040A1OMP11 1000 A 14-1/2 1- 3-3/8 11-3/4 113
TM9E0601312MP11 1200 B 17-1/2 1- 6-3/8 13-1/4 122
TM9E080612MP11 1200 B 17-1/2 16-3/8 14-3/4 126
TM9E080C16MP11 1600 C 21 19-7/8 16-1/2 136
TM9E100C16MP11 1600 C 21 19-7/8 18-1/4 142
TM9E100C2OMP11 2000 C 21 19-7/8 18-1/4 145
TM9E120D2OMP11 2000 D 24-1/2 2- 3-3/8 21-3/4 156
Ratings&Physical I Electrical Data
Nominal Air Temp. Max.Outlet Max Min.wire Size
BTUH(kW) Output Airflow AFUE Rise Air Temp Blower Blower Over-Current Total Unit (aw9)@ 75 ft
Input MBH CFM % °F °F HP Amps Size Protect Amps one way
TM9E040A1OMP11 38 1000 95.0 45-75 180 1/2 6.8 11x8 ' 15 9.5 14
TM9E0601312MP11 57 1200 95.0 40-70 180 1/2 6.8 11x8 15 9.5 14
TM9E080B12MP11' 76 1200 95.0 50-80 170 1/2 6.8 11x8 ' 15 9.5 14
TM9E080C16MP11 76 1600 95.0 40-70 165 1/2 6.8 11x10 15 9.5 14
TM9E100C16MP11 95 1600 95.0 ' 45-75 170 ' 1/2 6,8 11x10 ' 15 9.5 14
TM9E100C2OMP11 95 2000 95.0 50-80 165 . 3/4 8.4 11x11 15 10.9 ' 14
TM9E120D2OMP11 114 2000 95.0 50-80 175 3/4 8.4 11x11 15 10.9 14
NOTES:
Annual Fuel Utilization Efficiency(AFUE)numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code(NFPA-70-latest edition)and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018
I
Setting 1be Itylonsanre Slowdatd. Luxaire Page: 10
LUXU/RE Indoor Coil Multi-Position
rtld�lY)'.+.Ill:fYiii)1.1.1/f
Project Name: StorQuest-Tigard Unit Model#: CM48CBBA1
Quantity: 1 Tag#:C-1 System: TCD48B31S,TM9E100C20MP11,CM48CBBA1
Cooling Performance
Total gross capacity 47.5 MBH
Sensible gross capacity 35.3 MBH
Ambient DB temp. 95.0 °F
Refrigerant
Refrigerant type R-410A
Coil Dimensions&Weight
Hgt 33 in. Len 22 in. Wth 21 in.
Weight with factory installed options 64 lbs.
Matchup Information
ARI Reference Number 9734087
ARI Rated Capacity 47 MBH
SRI Rated Efficiency 14.75 SEER)
Note: Please refer to the tech guide for listed maximum static pressures *AP
AMERICAN
Ana CERTIFIED. c®w Unit Features
• CM Series is Multi-Position;Designed for Upflow/Horizontal Left
Application And Are Convertible to Downflow/Horizontal Right.If removed
from Case,will need Diverter Available on Accessory Page.
• Copper Sweat Connect Fittings
• Aluminum Tube/Aluminum Fin Coil
• Rigid Case Construction Interior Endoskeleton for Structural Support,Flush
Side,and Locks in Insulation
• G30 Galvanized Steel Case
• Long Life Aluminum Coils
• Quality Aluminum or G90 Galvanized Steel Construction
• Foil Faced Improved Insulation Design
• Bolt-on-TXV Provides Easy Installation;Some Models Are Available with
Factory Installed TXV
• 20.5"Casing for Easy Attic Access
• Thermal Plastic Drain Pan
Warranty
• Five(5)Year Limited Parts Warranty
• Ten(10)Years Extended Limited Parts Warranty(with Registration)
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018
Selling The Arliwor.roce Yadlre Luxaire Page:11
LIIXAIRf Indoor Coil Multi-Position
Project Name: StorQuest-Tigard Unit Model#: CM48CBBA1
Quantity: 1 Tag#:C-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1
Factory Installed Options
CM48CBBA1
Equipment Options Option(s) Selected
Product Type: C Coil
Product Category: M Mult-Position Cased
Capacity: 48 4 Ton
Cabinet Width: C 21"Cabinet Width
Refrigerant/TXV: BB Factory Installed TXV Coils
Coil Options: A Aluminum Tube
Product Generation: 1
Field Installed Accessories
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018
Senn,me Prriormanne
Vandafd
Luxaire Page: 12
LURA/RE Indoor Coil Multi-Position
Project Name: StorQuest-Tigard Unit Model#: CM48CBBA1
Quantity: 1 Tag#:C-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1
CM Coil Dimensions
DIMENSIONS CM
Refrigerant
19118, t/. O Dimensions 2 Connections3,4,5
(OPENING)/ s (OPENING) Models1
Height Width Opening Widths Line Size
' \ A B C D iLiquid Vapor
'k CM18A*A1 19-1/2 14-1/2 13-1/2 13-1/2
CM18BXA1 19 17-1/2 16-1/2 16-1/2
` CM24A'A1 19-1/2 14.112 13.112 13-1/2
A CM24B*A1 19 17-1/2 16-1/2 16-1/2
CM24CXA1 21 21 20 20
CM30A*A1 25-1/2 14-1/2 13-1/2 13.112
CM30B*A1 23 17-1/2 16-1/2 16-1/2 3/4
CM3OCXA1 23 21 20 20
`� / CM30DXA1 25 24/1/2 23-1/2 23-1/2
1 CM36AXA1 25-1/2 14-1/2 13-1/2 13-1/2 318
8 i20-1122, CM36B*A1 25-5/8 17-1/2 16-1/2 16-1/2
N\ i `1-112" CM36C*A1 25 21 20 20
/ CM36DXA1 25 24-1/2 23-1/2 23-1/2
1' CM42C*A1 27 21 20 20
` CM42DXA1 27 24-1/2 23-1/2 23-1/2
BOTTOM OPENING CM48C*A1 33 21 20 20
DIMENSIONS CM48D*A1 32-314 24-1/2 23-1/2 23-1/2 7/8
19118 CM60C*A1 33 21 20 20
D(OPENING)
AO323-0Ot CM60D*A1 32-3/4 24-1/2 23-1/2 23-1/2
CM64DXA1 32-3/4 24-1/2 23.112 23-1/2
1.Asterisk(*)denotes coil model is available as a flex coil or with factory installed TXV.
2.All dimensions are in inches,
3. Refrigerant line sizes may require larger lines for extended line lengths.See Application Data part number 247077.
4.Adapter fitting must be field installed for other line set size.
5. See outdoor unit technical guide for proper line set size.
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018
BACK
•
SUBMI'11AL MicroMet' YORK UPFLOW UNITS PART NUMBER:
(PAGE 1 of 2)
FORM NUMBER: 7717-2P
DATE: 01/2010 GY9SO40Al2UP11, (G,L)Y8SO40Al2UH11, (G,L)Y8S060Al2UH11, (G,L)Y8S080Al2UH11, a
COMPANY: A PS8Al2(N,L)040UH11, PS8Al2(N,L)060UH11, PS8Al2(N,L)080UH11, PS9Al2N040UP11, N
PT8Al2N040UH11, PT8Al2(N,L)060UH11, PT8Al2(N,L)080UH11, PT9Al2N040UP11
DRAWN BY: JD G8C05012MUB12, G8C07512MUB12, (G,L)Y8S080B16UH11, (G,L)Y8S100B16UH11, 6,5
JOB NAME: B (G,L)Y8S100B12UH11, GY9S060B12UP11, GY9S080B12UP11, PS8B12(N,L)1000H11, o
WEIGHT: N/A PS9B12N060UP11, PS9B12N080UP11, PT8B12N1000H11, PT9B12N060UP11, o
PT9B12N080UP11, PS8B16(N,L)080UH11, PS8B16(N,L)1000H11, PT8B16(N,L)080UH11
FEATURES G8C07516MUC12, G8C10016MUC12, (G,L)Y8SO8OC16UH11,
(G,L)Y8S100C16UH11,(G,L)Y8S100C20UH11, (G,L)Y8S115C2OUH11, GY9S080C2OUP11,
* FACTORY ASSEMBLED GY9S100C2OUP11, GY8S115C16UH11, GY9S080C16UP11, GY9S100C16UP11, b
PS8C16(N,L)080UH11, PS8C16(N,L)1000H11, PS8C16N115UH11, PS9C16N080UP11,
j
* FULLY INSULATED
* PAINTED CONSTRUCTION PS9C16N1000P11, PT8C16(N,L)080UH11, PT8C16N120UH11, PT9C16N080UP11, Q
* MULTIPLE CONFIGURATIONS PT9C16N1000P11, LY8S080C20UH11, PS8C20(N,L)1000H11, PS8C20(N,L)115UH11, I-
* FREIGHT INCLUDED PS9C2ONO8OUP11, PS9C2ON1000P11, PT8C20(N,L)1000H11, PT8C20(N,L)120UH11, Q
PT9C2ON1000P11, GY8S080C22UH11, PS8C22N080UH11, PS8C2OLO8OUH11 c
G8C10020MUD11, G8C12520MUD11, G8C15020UHD11, (G,L)Y8S130D2OUH11,
D GY9S120D2OUP11, GY9S135D2OUP11, PS8D20(N,L)130UH11, PS9D2ON120UP11, o
PS9D2ON135UP11, PT9D2ON120UP11 o
E - E-
F -
G - O`
H - }
0
MB - DF - A 2 C - ADB - BEL E
E
FAMILY PRODUCT ACTUATOR cn
GROUP HW:HONEYWELL
BEL:BELIMO T
BEL3:BELIMO(FLOATING POINT) t
FURNACE TYPE
I UF:UPFLOW FURNACE NA:NO ACTUATOR E
DE:DOWNFLOW FURNACE D
AH:AIR HANDLER CONTROLS ci)
ADB:ADJUSTABLE DRY BULB N
DESIGN DATA CABINET SIZE FDB:FIXED DRY BULB
A:A CABINET (ENT:ENTHALPY I Q
B:B CABINET NC :NO CONTROLS E
UNIT# IC:CCABINET(
m
D:D CABINET IR DAMPER 1-
CFM E:E CABINET C:C or D
A:AorE oo
DAMPER CONFIGURATION B'B
ILLUSTRATION Q
I1:B&Corp m
2:B&AorE
O/A SIDE 3:C&D Approved by: z
4 :A&E Date: X
ACTUATOR 5:C&E 2
D&A Openings and dimensions may vary
6:C&A from contract. An order -y
CONTROLS D&E constitutes acceptance of these variances
THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT.
MANUFACTUER RESERVES THE RIGHT TO DISCONTINUE,OR CHANGE AT ANYTIME,SPECIFICATIONS&DESIGNS WITHOUT ANY NOTICE AND WITHOUT INCURING OBLIGATIONS.COPYRIGHT MICROMETL CORPORATION 1999.ALL RIGHTS RESERVED C.O
MICROMETL CORPORATION'3035 N.SHADELAND AVE.,SUITE 300'INDIANAPOLIS,IN 46226*1-800-662-4822**'MICROMETL WEST•905 SOUTHERN WAY'SPARKS,NV 89431'1-800-884-4662
1-
SUBMITTAL MicroMetlMIXING BOX FOR PART NUMBER:
UPFLOW FURNACES MB-UF-*
DATE: 01/2010 (page 2 of 2)
SUBMITTED TO: - MMC P/N DAMPER WEIGHT A B C D
AIRFLOW
COMPANY: 14"
DRAWN BY: JD MB-UF-A* 960 CF M 55 lbs. 24 1/2" 13 1/4" or 10"
@ 12000 CF22"
JOB NAME: -
WEIGHT: SEE TABLE 1067 Ft/Min 16 1/4" or 12"
16
MB OF-B* @ 1600 CFM 60 lbs. 241/2"
22"
FEATURES1100 Ft/Min 20"
MB-UF-C* 65 lbs. 24 1/2" 19 3/4" or 16"
* FACTORY ASSEMBLED @ 2200 CFM 22"
* FULLY INSULATED -I
"
* MULTIPLE CONFIGURATIONS MB-UF D* @ 2300 CFM 70 lbs. 241/2" 23 1/2" 24 20"
* FREIGHT INCLUDED
1120 Ft/Min14
MB-UF-E* @ 1400 CFM 55 lbs. 22" 13" or 10"
22"
1200 Ft/Min16
MB-UF-F" @ 1800 CFM 58 lbs. 22" 16 1/4" or 12"
22"
1250 Ft/Min 20 d
MB-UF-G* @ 2500 CFM 63 lbs. 22" 19 3/4" or 16"
22"
(V
VERTICAL1000 Ft/Min 22" co
MB OF H* @ 2500 CFM 68 lbs. 22" 23 1/2" or 20"
ORIENTATION 24" o
EXAMPLE PART NUMBER: 3
MB-UF-C6A-ADB-HW
D USE FIELD SUPPLIED BLANK OFF FOR N
A "A"CABINET SIDE MOUNT APPLICATION
'( E „....g...„..., so a
B D;R°NI. 00 6H 18C/)
1/2" W TYP. TYP. Q
J
Cj
B 0D Li
c* / /
x
* D DAMPER m
28.500
C SIZE 2
A . 173
U)
44011411b, i E
• A 15
1 Tii
C* A D B 0,
CX
‹, m
0
I B E ONLY VERTICAL ORIENTATION z
IS SHOWN PLEASE NOTE TOP,
B / A FRONT,AND RIGHT SIDE OF X
��' FURNACE (AS SHOWN)WHEN 2
*THE "C" DIMENSION DEP. ► N CHOSING MIXING BOX ORIENTATION. ---
ON
ON DAMPER CONFIGURATION 3 MOUNTING OPTIONS `3
THE SMALLEST POSSIBLE MAY NOT BE AVAILABLE ON _D
DIMENSION WILL BE USED. THE FURNACE OR AIR HANDLER. O
THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED G10
WITHOUT MICROMETL'S WRITTEN CONSENT.MANUFACTUER RESERVES THE RIGHT TO DISCONTINUE,OR CHANGE AT ANYTIME,SPECIFICATIONS&DESIGNS WITHOUT ANY NOTICE
AND WITHOUT INCURING OBLIGATIONS.COPYRIGHT MICROMETL CORPORATION 1999. ALL RIGHTS RESERVED 17
MICROMETL CORPORATION`3035 N.SHADELAND AVE.,SUITE 300*INDIANAPOLIS,IN 46226"1-800-662-4822**"MICROMETL WEST*905 SOUTHERN WAY*SPARKS,NV 89431*1-800-884-4662