Loading...
Report (150) rcvEc_.acA- lag s Rckc c 2_v-v Setif"Melieosim uttdant, LII /RE X1471110+IIIR CDMO/71O NI11t SUBMITTAL DATA RECEIVED For: Approval OCT - 1 2018 Order#: Date: 09/26/2018 CITY OF TIGARD Project: StorQuest - Tigard BUILDING DIVISION Project#: Location: Tigard, OR. Purchaser: PMC Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018 Date 09/26/2018 Project Name Serrm*ThrAwfamsui rSrandu,r/. StorQuest-Tigard LU � E Project Number �,.,,kb•A,.CnMa,r,aHVI.4 Client/Purchaser PMC Submittal Summary Page Qty Tag# Model# Description 1 CU-1 TCD48B31 S Luxaire Brand, 4 Ton, Air Conditioner, R-410A Refrigerant, 13 SEER / 1-Stage, 208/230-3-60 1 F-1 TM9E100C2OMP11 Mid Tier, 95%AFUE, Single Stage Gas Valve, X13 ECM Motor, 100 MBH, 21"Width Cabinet, 2000 CFM Nominal, Multi-Position, 115-1- 60 1 C-1 CM48CBBA1 4 Ton, Mult-Position Cased, Coil, 21"Cabinet Width, Factory Installed TXV Coils, Aluminum Tube 1 S1-THXU280W Wi-Fi Communicating Touchscreen Thermostat with Proprietary Hexagon Interface (White) 1 S1-1BR0521 Bottom Return Filter Rack Galvanized (Fits 21"wide furnace) 1 S1-1CT0303 Concentric Vent Termination Kit-3" Equipment start-up and commissioning by a factory trained technician is recommended. Contact your supplying distributor or sales representative for additional information &guidance. WARNING:Cancer and Reproductive Harm-www.P65Warnings.ca.gov Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018 The u LX Series Page:3 LIIXAIRE 13 SEER A!/!IIID DII LDMDIIIDDIDD Project Name: StorQuest-Tigard Unit Model#: TCD48B31S Quantity: 1 Tag#:CU-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1 Cooling Performance , :,,, ..... Total gross capacity 47.5 MBH Sensible gross capacity 35.3 MBH 1UXAIRE Seasonal Efficiency(at ARI) 14.75 SEER • Efficiency(at ARI) 12.50 EER '. Ambient DB temp. 95.0 °F A, Power input 3.81 kW { Refrigerant , a� ': Refrigerant type R-410A Electrical Data Power supply 208/230-3-60 y Unit min circuit ampacity 18.4 Amps ;. Unit max over-current protection 30 Amps ='_- Dimensions&Weight >. Hgt 37 in. Len 37 in. Wth 34 in. Weight with factory installed options 200 lbs. Matchup Information _ _ 4 Ton ARI Reference Number 9734087 ARI Rated Capacity 47 MBH .40,RI Rated Efficiency 14.75 SEER J Product Features Note: Please refer to the tech guide for listed maximum static pressures • The TCD models are the latest iteration in our successful LX Series split MEI r system air conditioner lineup.Optimized for the 3 phase 13 SEER National A AMERICAN Minimum Efficiency,these outdoor units are specifically designed to be r+� CERTIFIED.nuaurr �s matched with Luxaire indoor coils,furnaces,and air handlers to provide a ° �c use" complete system solution. Unit Features • 13 SEER/1-Stage • Environmentally Friendly-CFC-free R-410A refrigerant delivers environmentally friendly performance with zero ozone depletion. • Durable Finish—A high quality powder paint finish rated at 1000 hrs.salt spray provides the ultimate protection from corrosion and harmful UV rays, ensuring a long-lasting,high quality appearance. • Fully Exposed Refrigerant Connections and a Single Panel Covering the Electrical Controls Make for Easy Servicing of the Unit Warranty • Standard One(1)-Year Limited Parts • Standard Five(5)-Years Limited Compressor • Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018 Ihr'm Standalrf. LX Series Page:4 IUXA/RE 13 SEER Project Name: StorQuest-Tigard Unit Model#: TCD48B31S Quantity: 1 Tag#:CU-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1 Factory Installed Options TCD48B31S Equipment Options Option(s) Selected Product Category: T Luxaire Brand Type: C Air Conditioner Nominal Series Efficiency&Staging: D 13 SEER/1-Stage Nominal Cooling Capacity: 48 4 Ton Refrigerant: B R-410A Refrigerant Voltage: 3 208/230-3-60 Product Generation: 1 Factory-Installed Options: S Field Installed Accessories S1-THXU280W-Wi-Fi Communicating Touchscreen Thermostat with Proprietary Hexagon Interface(White) (1.0 lbs) Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018 Salm 7Ar/Y.%rmwtt Sandler'. LX Series Page:5 LUXA/RE 13 SEER MfAlglf.Aw eo�unas/As Project Name: StorQuest-Tigard Unit Model#: TCD48B31S Quantity: 1 Tag#:CU-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1 TCD Typical Installation TYPICAL INSTALLATION A CAUTION: Special care must be taken to avoid recirculation of discharge air through condenser coil. NOTE: 48"OVERHEAD CLEARANCE \� asure adequate � wwall support. NEC CLASS 1 WIRING '. ate 1 kill WEATHERPROOF THERMOSTATS%SS �!/ DISCONNECT SWITCH �'�I � �..-10•St...I , NEC CLASS 2 WIRING ..'I I��. I 3 BRACES �-+ J Use for wall mount with \ S' center brace under SNIcenter of compressor. "�►�1 AI FURNACE OR \�� AIR HANDLER / \ TERMINAL BLOCK / \� NEC CLASS 2 WIRING ��...,, i ..., ., .. 10"CLEARANCE ��� ► A `�"� ki \�AROUND PERIMETER . 0 �/� il. (6"clearance .� /► �4) 10, permissible on one +� �� 'IL' i►.. side only,see `��;� ���� All outdoor wiring M `�r Alternative y `% must be weatherproof. .0 �' 1. Installation `�� I''� � �> �� Clearances.) N 5 �.'' / NOTE: CONTROL SEAL OPENINGS 5 SNOW PUMP-UPS Ensure a minimum of ACCESS Use in deep snow areas PANEL Use permagum or equivalent. with fifth pump-up under 24'clearance between any two units. MINIMUM 18"SERVICE ACCESS CLEARANCE center of compressor. Maintain minimum clearance on one side of access panel. A0200002 A CAUTION Care must be taken to prevent ice from damaging the unit.Damage may occur from ice falling onto unit from a sloped roof or from a vertical drip line due to a partial overhang. NO OVERHANG COVERING UNIT OVERHANG COMPLETELY \ COVERING UNIT OVERHANG PARTIALLY \ COVERING UNIT 1 --— 48"MINIMUM OVERHEAD CLEARANCE or t -- ,, ,. r E - r } r : i�, z -- Et= -1 " r T INSTALLATION ACCEPTABLE INSTALLATION ACCEPTABLE INSTALLATION NOT RECOMMENDED (Refer to CAUTION above.) (Refer to CAUTION above.) NOTE: NOTE: The unit must be installed on a solid base above the grade. Install unit on flat surface.If installation surface is sloped,ensure The base must not be able to settle or shift causing strain on that unit slopes away from house structure at 114"per foot. refrigerant lines and possible leaks. A CAUTION:Special care must be taken to avoid recirculation of discharge air through condenser coil. A0291.01 Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018 seraeg rnr w.weDwx.srrww. LX Series Page:6 IUXAIRE 13 SEER tArfO1•API COND,lIONIID Project Name: StorQuest-Tigard Unit Model#: TCD48B31S Quantity: 1 Tag#:CU-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1 TCD Physical&Electrical Gen2 PHYSICAL AND ELECTRICAL DATA MODEL TCD30 TCD36 TCD42 TCD48 TCD60 TCD30 TCD36 TCD42 TCD48 TCD60 TCD36 TCD48 TCD60 B32S B32S B32S B31SS B31SS B42S B42S B42S B41SS B41SS B52S B51SS B51SS Unit Supply Voltage 208-230V,30,60Hz 460V,30,60Hz 575V,30,60Hz Normal Voltage Range 1 187 to 252 432 to 504 540 to 630 Minimum Circuit Ampacity 11.91 14.34 15.29 18.4 21.2 5.67 7.85 7.68 8.4 10.3 5.30 6.6 7.7 Max.Overcurrent Device Amps 2 20 20 25 30 35 15 15 15 15 15 15 15 15 Min.Overcurrent Device Amps 3 15 15 20 20 25 15 15 15 15 15 15 15 15 Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Compressor Rated Load 8.89 10.43 11.19 13.7 15.9 4.22 5.76 5.63 6.2 7.7 3.77 4.8 5.7 Locked Rotor 58.0 73.0 84.0 83.1 110.0 38.0 38.0 44.0 41.0 52.0 36.5 33.0 38.9 Crankcase Heater No No No No No No No No No No No No No Factory External Discharge Muffler No No Yes No No No No Yes No No No No No Fan Diameter Inches 22 22 24 24 26 22 22 24 24 26 22 24 26 Rated HP 1/8 1/4 1/4 1/4 1/4 1/8 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Rated Load Amps 0.80 1.3 1.3 1.30 1.30 0.40 0.65 0.65 0.65 0.65 0.58 0.58 0.58 Fan Motor Nominal RPM 1075 850 850 850 850 1075 850 850 850 850 850 850 850 Nominal CFM 2950 3275 3550 3500 4300 2850 3200 3650 3650 4075 3300 3550 4125 Face Area Sq.Ft. 13.83 17.37 18.74 18.74 23.40 13.83 17.37 18.74 18.74 23.40 17.37 18.74 23.40 Coil Rows Deep 1 1 1 1 1 1 1 1 1 1 1 1 1 Fins/Inch 23 23 23 23 23 23 23 23 23 23 23 23 23 Liquid Line Set OD(Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD(Field Installed)4 3/4 3/4 7/8 7/8 1-1/8$ 3/4 3/4 7/8 7/8 1-1/81 3/4 7/8 1-18$ Unit Charge(Lbs.-Oz.)5 3-15 4-10 4-15 4-15 5-12 3-15 4-10 4-15 4-15 5-12 4-10 4-15 5-12 Charge Per Foot,Oz. 0.62 0.62 0.67 0.67 0.75 0.62 0.62 0.67 0.67 0.75 0.62 0.67 0.75 Operating Weight Lbs. 140 160 200 200 205 140 160 200 200 205 160 200 205 1. Rated in accordance with AHRI Standard 110-2012,utilization range W. 2. Dual element fuses or HACR circuit breaker.Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker.Minimum recommended overcurrent protection. 4. For applications with non-standard vapor line sizes,see the'Applications 8 Accessories"section of this Technical Guide. 5. The Unit Charge is correct for the outdoor unit,smallest matched indoor unit,and 15 feet of refrigerant tubing.For tubing lengths other than 15 feet,add or subtract the amount of refrigerant,using the difference in actual lineset length(not the equivalent length)multiplied by the per foot value. DIMENSIONS Unit Dimensions Refrigerant Connection Model (Inches) Service Valve Size A B C Liquid Vapor TCD30B(3,4)2S 30 29-1/4 29-1/4 34 TCD36B(3,4,5)2S 36-1/4 29-1/4 29-1/4 _ TCD42B(3,4)2S 33-1/4 35-1/4 31-3/4 3/8 7/8 TCD48B(3,4,5)1S 33-1/4 35-1/4 31-3/4I A TCD60B(3,4,5)1S 36-1/4 38 34-1/4 7/8$ I Adapter fitting must be field installed for the required 1-1/8"line set. All dimensions are in inches and are subject to change without notice. Overall height is from bottom of base pan to top of fan guard. Overall length and width include screw heads. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018 &WigIke R, ...tA ,,. Luxaire Page:7 LURA/RE. Single Stage ECM Multi-Position Gas Furnace NFA)IN•s,�1N::L•NNYIId•tXd Project Name: StorQuest-Tigard Unit Model#: TM9E100C2OMP11 Quantity: 1 Tag#:F-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1 C_ Cooling Performance Total gross capacity 47.5 MBH Sensible gross capacity 35.3 MBH ,. ,e. Entering DB temp. 80.0 °F = N Entering WB temp. 67.0 °F Leaving DB temp. 61.3 °F -#„ ' Leaving WB temp. 58.5 °F Heating Performance Entering DB temp. 60 °F It Heating output capacity(Max) 95 MBH �4 ;, . Supply air 1750 CFM A} - I Heating input capacity(Max) 100 MBH C Leaving DB temp. 110.3 °F 11 Air temp.rise 50.3 °F AFUE 95.0 % Supply Air Blower Performance Supply air 1750 CFM Ext.static pressure 0.88 IWG Unit Features Blower speed description HIGH Motor rating 0.75 HP • Unit Cabinet Constructed of Pre-Painted Steel Elevation 0 ft. • Sharp Edges Have Been Eliminated by Folding and Flattening the Sheet Drive type DIRECT Metal Indoor Electrical Data • Full-Gasket,Rigid Independent Access Doors With View Ports and 1/4 Turn Power supply 115-1-60 Knobs Unit min circuit ampacity 10.90 Amps • Units are factory shipped for installation in upflow or horizontal applications Unit max over-current protection 15 Amps and may be converted for downflow applications. Indoor Dimensions&Weight • Hi-tech Tubular Aluminized Steel Primary Heat Exchanger with Stainless Hgt 33 in. Len 29.5 in. Wth 21 in. Steel Tube/Aluminum Fin Secondary Heat Exchanger for Outstanding Weight with factory installed options 145 lbs. Efficiency. Matchup Information • Propane Convertible ARI Reference Number 9734087 • Slide-Out Direct Drive Blower with High Efficiency Brushless DC Motor ARI Rated Capacity 47 MBH • Airflow Leakage Rate of Less Than 1%of Total Airflow @ 1"ESP Under SRI Rated Efficiency 14.75 SEER) Duct Testing Conditions Note: Please refer to the tech guide for listed maximum static pressures • Built-In,High-Level Self-Diagnostic Controls with Fault Codes for Reliable ®(v Operation MPS �- AMEi1CAN CERTIFIED- .�r ---.�. nu..am, ,..,„ Warranty "'"""°"°""° �I • Five(5)Year Limited Parts Warranty • A 20-year limited warranty on heat exchangers in residential applications. • A 10-year warranty on heat exchangers in commercial applications. • Extended lifetime heat exchanger and 10-year limited parts warranty when product is registered online within 90 days of purchase for replacement or closing for new home construction. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018 Sating Perlitmanre Luxaire Page:8 LURA/RE Single Stage ECM Multi-Position Gas Furnace Project Name: StorQuest-Tigard Unit Model#: TM9E100C2OMP11 Quantity: 1 Tag#:F-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1 Factory Installed Options TM9E100C2OMP11 Equipment Options Option(s) Selected Brand: T Tier: M Mid Tier Efficiency: 9 95%AFUE Type: E Single Stage Gas Valve,X13 ECM Motor BTU Input: 100 100 MBH Cabinet Width: C 21"Width Cabinet Airflow: 20 2000 CFM Nominal Configuration: MP Multi-Position Voltage: 1 115-1-60 Product Generation: 1 Field Installed Accessories • S1-1BR0521 - Bottom Return Filter Rack Galvanized (Fits 21" wide furnace) (10.0 lbs) • S1-1 CT0303-Concentric Vent Termination Kit-3" (9.0 lbs) Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018 N setting"y'«/ pu"c/,. Luxaire Page:9 L�1�f/I/)•L" Single Stage ECM Multi-Position Gas Furnace I!A!/All�A/1 t1Ml/II11YIk1 Project Name: StorQuest-Tigard Unit Model#: TM9E100C2OMP11 Quantity: 1 Tag#:F-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1 Dimensions&Clearances LEFT SIDE FRONT RIGHT SIDE Combustion Air Inlet dr Combustion Air Inlet S •• Condensate Drain' Gas Pipe ! ' (Downflow) ��Entry Gas Pipe Condensate Drain • Entry (Downflow) — Vent Outlet 10 Electrical p�'��Entry Electrical — Condensate o Entry Vent Outlet Drain , m m . 33 Condensate --k.►o 23" r 1 m Drainr -1 t 0 D 11 Thermostat o Wiring ; Thermostat fl 'O Wiring Optional Return Air Cutout(Either side) 14' • 28.5" ►I�29.5" —* A—i{ 1.s"-01 I41 T 56" �Ii 23.8" 3" 4) ��.1II VentDI-7 Outlet g Combustion g Air Inlet C 1 .56„-01-.56” 20" ---------- Fill 24.25" 01 SUPPLY END RETURN END Cabinet&Duct Dimensions BTUH(kW) Nominal Cabinet Cabinet Dimensions(Inches) Approximate Operating Weights Input CFM(m3/min) Size A B C Lbs TM9E040A1OMP11 1000 A 14-1/2 1- 3-3/8 11-3/4 113 TM9E0601312MP11 1200 B 17-1/2 1- 6-3/8 13-1/4 122 TM9E080612MP11 1200 B 17-1/2 16-3/8 14-3/4 126 TM9E080C16MP11 1600 C 21 19-7/8 16-1/2 136 TM9E100C16MP11 1600 C 21 19-7/8 18-1/4 142 TM9E100C2OMP11 2000 C 21 19-7/8 18-1/4 145 TM9E120D2OMP11 2000 D 24-1/2 2- 3-3/8 21-3/4 156 Ratings&Physical I Electrical Data Nominal Air Temp. Max.Outlet Max Min.wire Size BTUH(kW) Output Airflow AFUE Rise Air Temp Blower Blower Over-Current Total Unit (aw9)@ 75 ft Input MBH CFM % °F °F HP Amps Size Protect Amps one way TM9E040A1OMP11 38 1000 95.0 45-75 180 1/2 6.8 11x8 ' 15 9.5 14 TM9E0601312MP11 57 1200 95.0 40-70 180 1/2 6.8 11x8 15 9.5 14 TM9E080B12MP11' 76 1200 95.0 50-80 170 1/2 6.8 11x8 ' 15 9.5 14 TM9E080C16MP11 76 1600 95.0 40-70 165 1/2 6.8 11x10 15 9.5 14 TM9E100C16MP11 95 1600 95.0 ' 45-75 170 ' 1/2 6,8 11x10 ' 15 9.5 14 TM9E100C2OMP11 95 2000 95.0 50-80 165 . 3/4 8.4 11x11 15 10.9 ' 14 TM9E120D2OMP11 114 2000 95.0 50-80 175 3/4 8.4 11x11 15 10.9 14 NOTES: Annual Fuel Utilization Efficiency(AFUE)numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code(NFPA-70-latest edition)and all local codes. The furnace shall be installed so that the electrical components are protected from water. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018 I Setting 1be Itylonsanre Slowdatd. Luxaire Page: 10 LUXU/RE Indoor Coil Multi-Position rtld�lY)'.+.Ill:fYiii)1.1.1/f Project Name: StorQuest-Tigard Unit Model#: CM48CBBA1 Quantity: 1 Tag#:C-1 System: TCD48B31S,TM9E100C20MP11,CM48CBBA1 Cooling Performance Total gross capacity 47.5 MBH Sensible gross capacity 35.3 MBH Ambient DB temp. 95.0 °F Refrigerant Refrigerant type R-410A Coil Dimensions&Weight Hgt 33 in. Len 22 in. Wth 21 in. Weight with factory installed options 64 lbs. Matchup Information ARI Reference Number 9734087 ARI Rated Capacity 47 MBH SRI Rated Efficiency 14.75 SEER) Note: Please refer to the tech guide for listed maximum static pressures *AP AMERICAN Ana CERTIFIED. c®w Unit Features • CM Series is Multi-Position;Designed for Upflow/Horizontal Left Application And Are Convertible to Downflow/Horizontal Right.If removed from Case,will need Diverter Available on Accessory Page. • Copper Sweat Connect Fittings • Aluminum Tube/Aluminum Fin Coil • Rigid Case Construction Interior Endoskeleton for Structural Support,Flush Side,and Locks in Insulation • G30 Galvanized Steel Case • Long Life Aluminum Coils • Quality Aluminum or G90 Galvanized Steel Construction • Foil Faced Improved Insulation Design • Bolt-on-TXV Provides Easy Installation;Some Models Are Available with Factory Installed TXV • 20.5"Casing for Easy Attic Access • Thermal Plastic Drain Pan Warranty • Five(5)Year Limited Parts Warranty • Ten(10)Years Extended Limited Parts Warranty(with Registration) Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018 Selling The Arliwor.roce Yadlre Luxaire Page:11 LIIXAIRf Indoor Coil Multi-Position Project Name: StorQuest-Tigard Unit Model#: CM48CBBA1 Quantity: 1 Tag#:C-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1 Factory Installed Options CM48CBBA1 Equipment Options Option(s) Selected Product Type: C Coil Product Category: M Mult-Position Cased Capacity: 48 4 Ton Cabinet Width: C 21"Cabinet Width Refrigerant/TXV: BB Factory Installed TXV Coils Coil Options: A Aluminum Tube Product Generation: 1 Field Installed Accessories Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018 Senn,me Prriormanne Vandafd Luxaire Page: 12 LURA/RE Indoor Coil Multi-Position Project Name: StorQuest-Tigard Unit Model#: CM48CBBA1 Quantity: 1 Tag#:C-1 System: TCD48B31S,TM9E100C2OMP11,CM48CBBA1 CM Coil Dimensions DIMENSIONS CM Refrigerant 19118, t/. O Dimensions 2 Connections3,4,5 (OPENING)/ s (OPENING) Models1 Height Width Opening Widths Line Size ' \ A B C D iLiquid Vapor 'k CM18A*A1 19-1/2 14-1/2 13-1/2 13-1/2 CM18BXA1 19 17-1/2 16-1/2 16-1/2 ` CM24A'A1 19-1/2 14.112 13.112 13-1/2 A CM24B*A1 19 17-1/2 16-1/2 16-1/2 CM24CXA1 21 21 20 20 CM30A*A1 25-1/2 14-1/2 13-1/2 13.112 CM30B*A1 23 17-1/2 16-1/2 16-1/2 3/4 CM3OCXA1 23 21 20 20 `� / CM30DXA1 25 24/1/2 23-1/2 23-1/2 1 CM36AXA1 25-1/2 14-1/2 13-1/2 13-1/2 318 8 i20-1122, CM36B*A1 25-5/8 17-1/2 16-1/2 16-1/2 N\ i `1-112" CM36C*A1 25 21 20 20 / CM36DXA1 25 24-1/2 23-1/2 23-1/2 1' CM42C*A1 27 21 20 20 ` CM42DXA1 27 24-1/2 23-1/2 23-1/2 BOTTOM OPENING CM48C*A1 33 21 20 20 DIMENSIONS CM48D*A1 32-314 24-1/2 23-1/2 23-1/2 7/8 19118 CM60C*A1 33 21 20 20 D(OPENING) AO323-0Ot CM60D*A1 32-3/4 24-1/2 23-1/2 23-1/2 CM64DXA1 32-3/4 24-1/2 23.112 23-1/2 1.Asterisk(*)denotes coil model is available as a flex coil or with factory installed TXV. 2.All dimensions are in inches, 3. Refrigerant line sizes may require larger lines for extended line lengths.See Application Data part number 247077. 4.Adapter fitting must be field installed for other line set size. 5. See outdoor unit technical guide for proper line set size. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 09/26/2018 BACK • SUBMI'11AL MicroMet' YORK UPFLOW UNITS PART NUMBER: (PAGE 1 of 2) FORM NUMBER: 7717-2P DATE: 01/2010 GY9SO40Al2UP11, (G,L)Y8SO40Al2UH11, (G,L)Y8S060Al2UH11, (G,L)Y8S080Al2UH11, a COMPANY: A PS8Al2(N,L)040UH11, PS8Al2(N,L)060UH11, PS8Al2(N,L)080UH11, PS9Al2N040UP11, N PT8Al2N040UH11, PT8Al2(N,L)060UH11, PT8Al2(N,L)080UH11, PT9Al2N040UP11 DRAWN BY: JD G8C05012MUB12, G8C07512MUB12, (G,L)Y8S080B16UH11, (G,L)Y8S100B16UH11, 6,5 JOB NAME: B (G,L)Y8S100B12UH11, GY9S060B12UP11, GY9S080B12UP11, PS8B12(N,L)1000H11, o WEIGHT: N/A PS9B12N060UP11, PS9B12N080UP11, PT8B12N1000H11, PT9B12N060UP11, o PT9B12N080UP11, PS8B16(N,L)080UH11, PS8B16(N,L)1000H11, PT8B16(N,L)080UH11 FEATURES G8C07516MUC12, G8C10016MUC12, (G,L)Y8SO8OC16UH11, (G,L)Y8S100C16UH11,(G,L)Y8S100C20UH11, (G,L)Y8S115C2OUH11, GY9S080C2OUP11, * FACTORY ASSEMBLED GY9S100C2OUP11, GY8S115C16UH11, GY9S080C16UP11, GY9S100C16UP11, b PS8C16(N,L)080UH11, PS8C16(N,L)1000H11, PS8C16N115UH11, PS9C16N080UP11, j * FULLY INSULATED * PAINTED CONSTRUCTION PS9C16N1000P11, PT8C16(N,L)080UH11, PT8C16N120UH11, PT9C16N080UP11, Q * MULTIPLE CONFIGURATIONS PT9C16N1000P11, LY8S080C20UH11, PS8C20(N,L)1000H11, PS8C20(N,L)115UH11, I- * FREIGHT INCLUDED PS9C2ONO8OUP11, PS9C2ON1000P11, PT8C20(N,L)1000H11, PT8C20(N,L)120UH11, Q PT9C2ON1000P11, GY8S080C22UH11, PS8C22N080UH11, PS8C2OLO8OUH11 c G8C10020MUD11, G8C12520MUD11, G8C15020UHD11, (G,L)Y8S130D2OUH11, D GY9S120D2OUP11, GY9S135D2OUP11, PS8D20(N,L)130UH11, PS9D2ON120UP11, o PS9D2ON135UP11, PT9D2ON120UP11 o E - E- F - G - O` H - } 0 MB - DF - A 2 C - ADB - BEL E E FAMILY PRODUCT ACTUATOR cn GROUP HW:HONEYWELL BEL:BELIMO T BEL3:BELIMO(FLOATING POINT) t FURNACE TYPE I UF:UPFLOW FURNACE NA:NO ACTUATOR E DE:DOWNFLOW FURNACE D AH:AIR HANDLER CONTROLS ci) ADB:ADJUSTABLE DRY BULB N DESIGN DATA CABINET SIZE FDB:FIXED DRY BULB A:A CABINET (ENT:ENTHALPY I Q B:B CABINET NC :NO CONTROLS E UNIT# IC:CCABINET( m D:D CABINET IR DAMPER 1- CFM E:E CABINET C:C or D A:AorE oo DAMPER CONFIGURATION B'B ILLUSTRATION Q I1:B&Corp m 2:B&AorE O/A SIDE 3:C&D Approved by: z 4 :A&E Date: X ACTUATOR 5:C&E 2 D&A Openings and dimensions may vary 6:C&A from contract. An order -y CONTROLS D&E constitutes acceptance of these variances THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT. MANUFACTUER RESERVES THE RIGHT TO DISCONTINUE,OR CHANGE AT ANYTIME,SPECIFICATIONS&DESIGNS WITHOUT ANY NOTICE AND WITHOUT INCURING OBLIGATIONS.COPYRIGHT MICROMETL CORPORATION 1999.ALL RIGHTS RESERVED C.O MICROMETL CORPORATION'3035 N.SHADELAND AVE.,SUITE 300'INDIANAPOLIS,IN 46226*1-800-662-4822**'MICROMETL WEST•905 SOUTHERN WAY'SPARKS,NV 89431'1-800-884-4662 1- SUBMITTAL MicroMetlMIXING BOX FOR PART NUMBER: UPFLOW FURNACES MB-UF-* DATE: 01/2010 (page 2 of 2) SUBMITTED TO: - MMC P/N DAMPER WEIGHT A B C D AIRFLOW COMPANY: 14" DRAWN BY: JD MB-UF-A* 960 CF M 55 lbs. 24 1/2" 13 1/4" or 10" @ 12000 CF22" JOB NAME: - WEIGHT: SEE TABLE 1067 Ft/Min 16 1/4" or 12" 16 MB OF-B* @ 1600 CFM 60 lbs. 241/2" 22" FEATURES1100 Ft/Min 20" MB-UF-C* 65 lbs. 24 1/2" 19 3/4" or 16" * FACTORY ASSEMBLED @ 2200 CFM 22" * FULLY INSULATED -I " * MULTIPLE CONFIGURATIONS MB-UF D* @ 2300 CFM 70 lbs. 241/2" 23 1/2" 24 20" * FREIGHT INCLUDED 1120 Ft/Min14 MB-UF-E* @ 1400 CFM 55 lbs. 22" 13" or 10" 22" 1200 Ft/Min16 MB-UF-F" @ 1800 CFM 58 lbs. 22" 16 1/4" or 12" 22" 1250 Ft/Min 20 d MB-UF-G* @ 2500 CFM 63 lbs. 22" 19 3/4" or 16" 22" (V VERTICAL1000 Ft/Min 22" co MB OF H* @ 2500 CFM 68 lbs. 22" 23 1/2" or 20" ORIENTATION 24" o EXAMPLE PART NUMBER: 3 MB-UF-C6A-ADB-HW D USE FIELD SUPPLIED BLANK OFF FOR N A "A"CABINET SIDE MOUNT APPLICATION '( E „....g...„..., so a B D;R°NI. 00 6H 18C/) 1/2" W TYP. TYP. Q J Cj B 0D Li c* / / x * D DAMPER m 28.500 C SIZE 2 A . 173 U) 44011411b, i E • A 15 1 Tii C* A D B 0, CX ‹, m 0 I B E ONLY VERTICAL ORIENTATION z IS SHOWN PLEASE NOTE TOP, B / A FRONT,AND RIGHT SIDE OF X ��' FURNACE (AS SHOWN)WHEN 2 *THE "C" DIMENSION DEP. ► N CHOSING MIXING BOX ORIENTATION. --- ON ON DAMPER CONFIGURATION 3 MOUNTING OPTIONS `3 THE SMALLEST POSSIBLE MAY NOT BE AVAILABLE ON _D DIMENSION WILL BE USED. THE FURNACE OR AIR HANDLER. O THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED G10 WITHOUT MICROMETL'S WRITTEN CONSENT.MANUFACTUER RESERVES THE RIGHT TO DISCONTINUE,OR CHANGE AT ANYTIME,SPECIFICATIONS&DESIGNS WITHOUT ANY NOTICE AND WITHOUT INCURING OBLIGATIONS.COPYRIGHT MICROMETL CORPORATION 1999. ALL RIGHTS RESERVED 17 MICROMETL CORPORATION`3035 N.SHADELAND AVE.,SUITE 300*INDIANAPOLIS,IN 46226"1-800-662-4822**"MICROMETL WEST*905 SOUTHERN WAY*SPARKS,NV 89431*1-800-884-4662