Plans (80)
Latimer HVAC HEATING•VENTILATION•AIR CONDITIONING ED Progressive TI Landlord Work RECErV 10656 SW Nimbus Ave Suite S-A SEP 2 5 2018 Tigard, OR 97223 CITY OF TIGARD BUILDING DIVISION Scope of Work Latimer HVAC will perform the following scope of work: 1. Provide and install new rooftop gaspack unit on existing curb. Use curb adapter and clips. Equipment Schedule RTU4-. Carrier 48TCDD12A2A6- 10 ton. 460/3/60, 24MCA, 30 MOCP. 2 speed VFD fan. 122,000 Btu cooling, 11.1 eer, 12.8 leer. 180,000 Btu input gas, 82%AFUE. 1218#. Economizer, curb adapter. OLD unit 48TJD016- 15ton. Weight = Existing curb to remain weight- 200#, Existing duct weight- 400#. Mechanical General Notes: 1. Cooling equipment does not exceed the load of the calculated requirement. 2. Fan motor does not exceed allowable,first available above BHP. 3. Reconnect to existing DDC system. 4. Max leakage rate of OSA or exhaust dampers to be 4 cfm/sft© 1.0 sp. 5. Provide 0 and M to building owner. OFFICE COPY Ventilation Requirements-based on 2014 OMSC table 403.3 CITY OF TIGARD See TI permit REVIE D FOR CODE COMPLIANCE Approved: GAS- OTC: ( I } Reduced Load- 270,000 Btu to 180, 000 Btu Permit #: rayl e a.Q g _ ,7 Address: 1 �O4.i�c (b_w < Suite #: ,s.. By: Date: 0-) )-)OF A DUCT THE ACTIVATION ECTOR SHALL SMOKE DE VISIBLE AND ACTIVATE A SORY AUDIBLE SUPERSTANTLY SIGNAL ATA C ATTENDED LOC4;10N M 0 OIVISC6 Latimer HVAC LLC 11230 SW Morgen Ct. (503) 290-1085 Oregon CCB 220839 Tigard, OR 97223 info@Iatimerhvac.com Washington LATIMHL825KQ p`& STRUCTURAL CALCULATIONS FOR PROGRESSIVE TI LANDLORD WORK 10656 SW NIMBUS AVE SUITE S-A TIGARD, OR 97223 -- ROOF MECHANICAL UNIT REPLACEMENT -- r S�RUCTURq< Oat PROFF' 12,187 i frf OR, ON O " tiN E. NOikcj EXPIRES:12/31/18 Contents Summary S1 Details A-B D1 -D2 Lateral Calculations L1 -L2 Contact Person: John E Nordling,PE Enclosures El -E5 NORDLING Proj. No.: 18-314 STRUCTURAL PROGRESSIVE TI LANDLORD WORK Ilk ENGINEERS, LLC LATIMERHVAC 6775 SW 111th,Suite 200•Beavertail OR,97008 Date: SEP 2018 By:JEN Sheet No.: COVER SUMMARY 2014 Oregon Structural Specialty Code Wind 120 M1 I-1 (3 sec gust, V uLT) Exp B Seismic Occupancy Catagory II Site Class - D Seisimic Design Catagory - D Ss = 0.913 Si = 0.424 SDs = 0.121 SDI = 0.445 There is one roof mounted '10-Ton' mechanical replacement unit. Existing 1RTU-4 48TJD016 - 15 Ton '10-Ton' unit: 45 TCD D12 weight 1,680 lbs weight 1,218 lbs 10-Ton 930 lbs Curb length 55' Adapter 165 lbs weight 200 lbs width 59' Economizer 123 lbs height 49' 1,218 lbs The roof curb and supporting structure are existing. The load to the existing supporting structure will be reduced by over 400 lbs. NORDLING Proj. No.: 18-314 STRUCTURAL PROGRESSIVE TI LANDLORD WORK ENGINEERS, LLC LATIMER HVAC 6775 SW 111th,Suite 200•Beaverton OR,97008 Date: SEP 2018 By:JEN Sheet No.: S1 . m III I l$ l u I 1 I (E) GIRDER TRUSS I I , } -------� - -=-----------------------MM -----, + �--- l l IIII , I I iI 7I II lk III I16 Il I III ,l , IiE � I X ALL SIDESO ; wII 1 - II I IA i E1EI i , - II IEI 4 II II I IE I i- — (E)2-zx6 — = y MM ---- I— 1 NI 1+ „ ii °I EE °HH WI IE I wI IE ii 61 ii 01 01 I11I l ly I i ly 1-1(.1 I llty Ii �, !� ! 1^V 11' 1-�►fI O PROF���,0 cu 12, ; 1 .Or •REGO I C ROOF PLAN v0��°F NOR���+� EXPIRES:12/31/18 NORDLING Proj. No.: 18-314 1 STRUCTURAL PROGRESSIVE TI LANDLORD WORK ENGINEERS, LLC LATIMER HVAC 8775 SW 111th,Suite 200•Beaverton OR,97008 Date:SEP 2018 By:JEN Sheet No.:D1 MECHANICAL UNIT (4) 'MH-PRC-HOLD' 16 Ga GALVANIZED STEEL BRACKET W/ (4) *10 x 1/2' TEK SCREWS TO CURB (BY -,i„,4 OTHERS) 4 (4) *I0 x lig' TEK SCREWS TO UNIT BASE RAIL 411111111111114P , ADAPTER CURB (4) *10 SCREWS MECHANICAL UNIT ,},/ , (4) *10 SCREWS--"' 1 %i� TEL BRACKET 1 <- II *12 SCREWS 612' o/c ALL SIDES UNIT BASE RAIL 1. ADAPTER CURB L.---(E) CURB .“,ucTUR,1 (E) FRAMING p PROFFf ��N0 I ..EER / ! 0 : 1 f:7 fo..; , veri OREt 0DETAIL� �oti��<� 's �v` =. F. NOR EXPIRES:12/31/18 NORDLING Proj. No.: 18-314 ''‘ .-- .'. STRUCTURAL ENGINEERS, LLC PROGRESSIVE TI LANDLORD WORK . LATIMER HVAC 6775 SW 111th,Suite 200•Beaverton OR,97008 Date: SEP 2018 By: JEN Sheet No.:D2 , ASCE 7.10Standard Roof Top Meth Unit Location 45°26'36.91"N Ss and S1=Mapped Spectral Acceleration Values 122°47'10.01" W 10656 SW Nimbus Ave,Tigard,OR 97223 Ground Motion Ss 0.973 Si 0.424 1 Occupancy Category II Site Coefficients Fa 1.11 Site Class D Fy 1,58 Importance Factor 1.00 Height of Structure 20.0 ft SMS Fa* Ss 1.081 SM!! Fy* Si 0.668 Design Category(SDC) D SDS (2/3)SMS 0.721 SDI (2/3)SMi 0.445 Air Side HVAC FP MIN= 0.3 SDs IP Wp ap 2.50 Rp 6.00 = 0.216 WP->* 0 0.151 0.4 a •SDS •' i FP 1+2. z •W FP MAX= 1.6 SDS IP Wp P p RP ` h, " = 1.15 Wp->*0 0.807 z= 20.0 ft ASD Fp= 0,36 Wp->*0.7 0.252 Eq= 0.286W+0.2 SDS W W :Weight of Unit z= 24.0 ft FP= 0.41 Wp->*0.7 0.286 ASCE 7.10 Wind Force Standard Roof Top Mich Unit Wind Speed: 120 mph Exposure: B Height of Structure 20'-0" assume Af<0.1 Bf::Force increase factor x=1.9 qZ: 23.24 psf kz: 0.70 Unit Weight 1,218 lbs Gust: 0.85 Ka: 0.90 Unit Height 49" Cf: 1.30 Kit: 1.00 Unit Length 88" x: 1.9 Unit Width 59" Curb Height 15" WP: 48.8 psf P: 877 lbs-ASD T= 877 lbs *(15"+49"/2)/59" - 0.6* 1,2181bs/2 = 222 lbs Net Uplift NORDLING Proj, No.: 18-314 P15 "‘„A--„,:a .wM STRUCTURAL PROGRESSIVE TI LANDLORD WORK j-,,,,, ‘, 4 ENGINEERS, LLC LATIMER HVAC 6775 SW 11Ith,Suite 200•Beaverton OR,97008 Date: SEP 2018 By:JEN Sheet No.:L1 ea a 176 Hos cg:4. W: 1,218 lbs , ,Ippor, , I � • I\ • 1101.000. veQ 384 lbs 144 .•001, , C: 45 lbs Height 49" Weight 1,218 lbs Length 88" Width 59" A.Curb 15" (4) 'MH-PRC-HOLD' 16 Ga GALVANIZED VEQ=0.286* 1,218 lbs+0,2* 0.721* 1,218 lbs STEEL BRACKET W/ (4) *10 x 1/2' TEK = 348 lbs+176 lbs SCREWS TO ROOF CURB 4 (4) *10 x vie' TEK SCREWS TO UNIT BASE RAIL T= 348 lbs * (15"+49"/2)/59" - - + 1761bs/2 - 0.6* 1,218 lbs/2 = -45 lbs [0 Net Uplift] *12 612' o/c SCREWS TO EXISTING CURB BELOW _ _ V= 348 lbs NORDLING Proj. No.: 18-314 !IISTRUCTURAL PROGRESSIVE TI LANDLORD WORK J7 ENGINEERS, LLC LATIMER HVAC 6775 SW 111th,Suite 200•Beaverton OR,97008 Date: SEP 2018 By:JEN Sheet No.:L2 Physical data -- 48TJ016-028 \(:f://c i EXISTING 40 UNIT SIZE 10160/EI 020D 0240/E 02801E 208/230,460 v 575 v NOMINAL CAPACITY(tons) 15 18 20 25 OPERATING WEIGHT(Ib) 1680 lbs Unit AI/A1* 1 wail 5(10 1850 1850/2031 2234/2413 Al/Cu* 11650/16701 1980 1980/2161 2364/2543 Cu/Cu* 1730/1750 2090 2090/2271 2474/2653 i Economizer 110 110 110 110 Root Curb** 200 200 200/213 200/213 COMPRESSOR Semi-Hermetic Hermetic Semi-Hermetic Quantity 1 2 1 2 2 011(oz) 130 65 ea 1 65 ea 152 ea REFRIGERANT TYPE R-22 Operating Charge(lb-oz) Circuit 1-ft 22 4 15-8 15-B 16-12 Circuit 2 — 15-8 15-8 15-12 CONDENSER COIL Enhanced Co er Tubes,Alu inum Lanced or Copper Fins Rows...Fins/tn. 3 13 6 4...15 4 15 .,.15 Total Face Area(sq ft) 18 9 22.2 22 2 1 422 2 CONDENSER FAN Propeller Type Nominal Ctm 12,000 14,200 14,200 14,200 Quantity...Diameter(in.) 2 26 2...30 2..30 2 30 Motor Hp...Rpm 1 .1075 1 .1075 1...1075 1...1075 Watts Input(Total) 3550 3400 3400 3400 EVAPORATOR COIL Copper Tubes,Aluminum or Copper Plate Fins Total Face AI ea(sq ft) 316 53 1 17 9 1.4 15 17.9 1 17 9 EVAPORATOR FAN Centrifugal Type Quantity...Size(in.) 2...10 x 10 2...10 x 10 2 .12 x 12 2..12 x 12 2. 12 x 12 Type Drive Belt Belt Belt Belt Belt Nominal Cfm 6000 6000 7200 8000 10,000 Motor Hp 3 7 3 0 5 71/2 10 8 7[208/230,575 v) 10 2[208/230,575 v] Maximum Continuous Bhp 4 25 3 45 5 90 9 5[460 v] 11 8[460 v] Motor Frame Size 56H 56H 184T 213T 215T Nominal Rpm High/Low — — — — — Fan Rpm Range 1194-1526 896-1161 1047-1251 1238-1494 1323-1579 I Motor Bearing Type Bali Ball Ball Ball Ball Maximum Allowable Rpm 1550 1550 1550 1550 1550 Motor Pulley Pitch Diameter Mtn/Max(in.) 3.4/4 4 4 0/5 0 4 9/5,9 5 4/6.4 5.8/7 0 Nominal Motor Shaft Diameter(In.) 7/a 7/e 11 1% 1% Fan Pulley Pitch Diameter(in.) 52 4 9 8.4 7 9 7 9 Nominal Fan Shaft Diameter(in.) 13ha 13/ie 17/16 1'/Ma 17As Belt,Quantity...Type...Length(in) 1 ..AX .42 1 .BX 38 1 BX..50 1 BX..50 1,,BX.51 Pulley Center Line Distance(In.) 13 5-15 5 13 5-15 5 13 3-14 8 14 6-15.4 14 6-15 4 Speed Change per Full Turn of Movable Pulley Flange(rpm) 66 54 34 43 43 Movable Pulley Maximum Full Turns From Closed Position 5 5 6 6 6 Factory Setting 3.5 3 5 3 3 3 Factory Speed Setting(rpm) 1293 975 1149 1366 1451 Fan Shaft Diameter at Pulley(in.) 13/16 13/,s 17/,a 17/ia 17h2 Equipment Schedule RTU4-. Carrier 48TCDD12A2A6- 10 ton. 460/3/60, 24MCA, 30 MOCP. 2 speed VFD fan. 122,000 Btu cooling, 11.1 eer, 12.8 leer. 180,000 Btu input gas, 82%AFUE. 1218#. Economizer, curb adapter. OLD unit 48TJD016- 15ton. Weight= 1680# Existing curb to remain weight-200#, Existing duct weight-400#. I 0 10 El Unit Report For rtu Project: --Untitledl 09/20/2018 Prepared By: 10:43AM Unit Parameters Dimensions(ft. in.)&Weight(lb.)*" f Unit Moder 48TCDD12A2A6-2U0G0 Unit Length' 7'4.125" Unit Size• 12(10 Tons) Unit Width: 4'11.5" Volts-Phase-Hertz. 460-3-60 Unit Height 4'1.375" Heating Type. Gas *** Total Operating Weight 1051 lb Duct Cfg' Vertical Supply/Vertical Return Low Heat *** Weights and Dimensions are approximate. Weight does Round Tube Plate Fin Coils not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size' 3/4 Condensate Drain Line Size. 3/4 Return Air Filter Type. Throwaway Return Air Filter Quantity. 4 Return Air Filter Size' 20 x 20 x 2 Unit Configuration Medium Static Option(Belt Drive) Al/Cu-Al/Cu RTU Open Controller Temp Ultra Low Leak Economizer w/Baro Relief Standard Packaging 2-Speed indoor fan motor controlled by VFD Warranty Information (Net Price Ea.) 1-Year parts(std.) $0 5-Year compressor parts(std.) $0 10-Year heat exchanger-Aluminized(std.) $0 15-Year heat exchanger-Stainless Steel(std.) $0 No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information 4 Part Number Description Quantity Master Price(ea.) 48TCDD12A2A6-2UOGO Rooftop Unit 1 $28,193 Base Unit $23,246 Medium Static Option(Belt Drive) $142 RTU Open controls Ultra Low Leak Temp Econo 2, baro relief-Meets $4,805 Calf.Title 24 FDD&Leak Rate 2 Speed Fan Controller (VFD) Packaged Rooftop Builder 1.49j Page 4 of 31 E2 Certified Drawing for rtu Project: '-Untitled! Prepared By: 09/20/2018 10:43AM NOTES: UNITED PA,aS 4W IRIS P000FYY IS THE nOrEArr Or CARRIEY Ca101SrIa SaKSSSa Or rKSE mia1 a RKUKRTS 1. DIMENSIONS ARE IN INCHES,DINENS[OXS UNIT COIL TTPE 3 N H TECHNOLOGIES srRAcaZ,Nr AMI IS aLJYEREH Ur0Y THE EOSE95 COaR10Y lai TK ROFd NII CaSTriaE rAtr rEtr01WKF a 3N[ ]ARE IN MILLIMETERS. CARRIER 1$221 Mian ll,5 rima rfar a au tllaa CAKIER ..m.MCE Or 111447. 41 1/4 481T-08N RTPF 33 15 7/8 2.s CENTER OF GRAVITY [1018] 06587 [403] 4BTC-A09 RTPF [12531 [/811 2[7087 CONNECTION SIZES 3.1100.DIRECTION OF AIR FLOG 49 3/6 37 1/4 15 7/8 A 1 318' [351 DIA FIELD PONES SUPPLY MOLE 48TC-Al2 RTPF [12531 [9483 [4431 110251 41 1/4 33 13 718 [10261 1 8 2 1/2' [847 DIA POSER SUPPLY KNOCKOUT 46TC-D08 RTPF [10481 [6581 14037 C 1 3/4'1511 014 GAUGE ACCESS PLUG 48TC-009 RTPF 49 3/6 37 1/4 15 118 D 7/8' 1221 0[A FOOLS CONTROL SIRING HOLE [12537 !4161 U031 - 49 3/e 37 711 15 7/e 20-3/4 E 3/4'-14 MPT CONDENSATE DRAIN 48TC-D12 RTPF [12531 !9481 [403] • ECONOMIZER HOOD [5277 (OPTIONAL) F 7/2'-14 NPT GAS CONNECTION 4BTC-DOR NCH 41 1/4 33 p3 3/4'-14 SEPT 6A5 CONNECTION I10187 [858] 1564.21 6 2•071 DIA POSER SUPPLY KNOCK-OUT 48TC-012 NCH% 49 318 37 1/1 17 [12537 [8411 [219.11 a • "� •. . . 4 RTPF-ROUND TUBE,PLATE FIN(COPPER/ALUM) / THRU-THE-BASE CHART (FIELD INST) MCN%-NOVATION IALUNIALUM> • / THESE MOLES REWIRED FUR USE WITH ACCP NITS: • /pp///�/ 38-3/8 12-5/6 CRBTMPWH002A01:GAS THRU CURB 111141II/A: Ii [9231 [3p17 CRBTNPSR004A41c US THRU BASEPAN M RETURN AIR RETURN 6 �I��-='���� J { AIR THREADED MIRE REO'D MOLE CONDUIT SIZE USE SIZES IMAX.) FILTER ACCESS PANEL \ r } I G 112' ACC. 718°122,21 • IR ACCEESSP I "II---, E ALT. I 5 1!P• 24V 718°122.21 �i CONDENSATE��DRAIN OPENING T 1 lA"IOD2,D04) PURER 1 314' [44.4] • . • COIDENSER /r \1 28-3/4 777 ' IN BASEPAN• [1311 37-5/8 40-3/8 INDOOR COIL • i 71�n1@\m IlJlllipI- A SEE THRU SUPPLY [9531 [1027] Z I 1004)3l/'FPT GAS 1 3/4' [44.47 ACCESS CAMEL ,���\\'"� ',7//////•M• Y THE BASE SUPPLY , 10021 PE FITTI 374'FPT TNRU CUA6 BACK (1401 1E 1/ '\\\ Z [HART AIR FLANGE A fITTIN6. HOOE SIZE:2'[50.8] 14121 [3551 11 �9 1z791 ' THRU-THE-BASE CHART (FIOP) I _V - I-7 1 i 8 1 y� 4 , • x) FITR TINGSUF-OHEONNLYEI,1, ORRY OPPTROVONIDos — L 8-1/4 FOR BELOW LISTED MODELS,A FIELD R 8-1/4 SUPPLIED 1/2'ADAPTER IS REQUIRED ---29-5/8—� L7007 `--FLUE .t.-3_711 "° BETWEEN BASE PAN FITTING AND GAS VALVE: [1511 HOOD TA [831 481CD,S408 TOP 0356] ---25-1/2 11 N Ian 1/A 4-s/8 [321 11-7/6 1118] ` _ ` [3021 j DISCONNECT CONTROL BOX _ —�III LOCATION ACCESS PANEL - ILTER CONDENSER B E STD. COIL I CONDENSATE DRAIN 3 UPTIONAL ACCESS BLOWER • OPTIONAL , FACTORY FACTORY 27_718 INSTALLED INSTALLED DISCONNECT [7017 • f 13918 [70A]1 AU'OUTSIDE CONVENIENCE I� ���---HHHANDLE Op. 59OUTLET C 133 ■ SUPPLY AIR 'vINANDLE�� [8it 6-5/8 _ • __ 26 i 4011 3 -- ME f• 1• 8-1/B —� — 8 � 110 I •I • I i �(��C ,[1511 — - 3-3/41171"11(111 [937 59-1/2 2-518--- 8-5/e 1 113101 [67] 31 [2141 [1871 37-7/8 fl T7] 6-1/8 4-3/8 TIP p401 [753] [1731 CURB [9627 LEFT RIDTN •"' 68-1/842-3/6 122383 SUPPLY [10757 BAROMETRIC FRONT 2: AIRURN RELIFLOWEF IIIrRIGHT SHEET WE SPUMES 48TC 08-12 SINGLE ZONE ELECTRICAL m 1 OF z 03-08-10 11-24-08 COOLING WITH GAS HEAT 48TN50R985 F Ci-, Packaged Rooftop Builder 1.49j Page 5 of 31 w Certified Drawing for rtu Project: --Untitled1 Prepared By: 09/20/2018 10:43AM up)TED r.0.99[9999 TNIS 90661 l0 19 nrt N9r[9n 0(wgTu cOtMyA7lgi `y�if7a O.7x[u 9w1YC6 09 99 8(0191 STD.UNIT COINER CORNER CORNER CORNER TECHNOLOGIES 9T9AC96E,Nr A [6 BEL ER[6 9Po9 INE 19r9E66 299972[09 r9AT 195 UNIT -- OUTDOOR WEIGHT 9.. 9576X7 141 WEIGHT 10) WEIGHT f C> WEIGHT[D> C.G. CARRIER Ism mum nu wr eE 97ttLL00�9 a WED nn�r cA96[99 OOFS bT 0999TITUTF IRR 19AFO9119[[M COIL TYPE COIM9A210N'S 9AIT7E9 M96E9T. BCCR2A9[E 9E C0919Ati. LBS. AG. LBS. KG. 185. KG. LBS. 86. LBS. KG. A r 2 4011-A98 RTPF 789 354 178 D1 158 72 299 95 236 107 41 1/2(1054] 33 1/0[8601 20 1/2 05211 r••STANDARD UNIT WEIGHT I5 WITH LOW GAS HEAT AND 81TH0UT PACGAGI116. 4810-A09 RIPE 920 418 212 96 103 83 243 110 282 128 40 1/B[1036] 34 18647 23 1/8[387] FOR OTHER OPTIONS AND ACCESSORIES,REFER TO THE PRODUCT DATA CATAL06. 48TC-Al2 RTPF 930 422 216 94 196 69 247 112 272 123.5 12 110671 33 1/8(8411 24 1/4 18161 4871-506 RIPE 835 379 104 74.5 170 77.2 255 115.6 246 111.7 44 1/5(1140] 35 5/8[903] 19 3/6 84921 48TC-098 RTPF 930 422 228 103.5 187 05 232 105.3 283 128.5 39 3/4 510101 32 1/8[8351 18 5/8 14731 481C-212 RTPF 940 427 231 104.9 189 85.2'234 106.2 286 129.8 39 3/4 11010] 33 58381 18 1/2[4707 4811-038 8146 805 305,5 160 72.6 153 69.3 240 109 26D 116 43[1002] 36 3/8 09241 20 3/6 5311.71 48TC-212 MCRA 895 406.3 185 84 106 19.9 260 118 274 124.4 42 118 110891 35 1/2 19027 22 7/8 15811 RTPF-ROUND TUBE, PLATE FIR(COPPER/ALUM) CORNER A MCRA-NOVATION(ALUM/ALUM) CORNER B Ilf (%%E\ 1. i '"'t /rte`, 1111 N 0111 /rWAOn] CORNER D CORNER C TOP A — • • 1. CD A • 2 1. cm 400 r Wail : : 00: FRONT 59992 BATE ur99c99Es 48TC 08-12 SINGLE ZONE ELECTRICAL 959 2 OF 2 03-08-10 11-24-08 COOLING WITH GAS HEAT 48144500985 F tt Packaged Rooftop Builder 1.49j Page 6 of 31 OPTIONS: DIMENSIONED AND TDLERENCED PER ANSI Yik5M-1982 REVISIONS MATERIAL: 18ga.GAL STEEL REV. DESCRIPTION DATE APPROVED INSULATED PANELS (WHERE REQUIRED) Attn: Tag: . I INITIAL DRAWING 6/23/2006 1"DUCT INSULATION (R VALUE 3.85) 2 UPDATED TOP BRACES 11/29/11 00 GASKET PROVIDED WITH CURB 1 1/2"ADDED TO EXISTING CURB O.D. Approval: SUPPLY AIR ---..- 17 9116" +— y � 01140 �. --2"TYP RETURN AIR .,�� \\�� i likr..4.* 44111000.. 33 1/4" ► 361/4" EXISTING CURB LAYOUT 1 INSULATED COVER 77 3/4" - 75 1/2" 41 15/16"---.^ SUPPLY 70 7/16" 56 1/2" 3611/16" RETURN 24 1/2" 1 ! . 2 1/4"—.1 2 1/4" 1 70 3/4" 1 81 3/4" 1 1 53 7/16" { 7" I16 - 79 1/4" I- 71 15/16" I CURB WEIGHT(LBS.) APPROVALS DATE me 163.40 °" esauntlers 1-4010-4005 CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO .•"""^".°^"- Wednesday,February 17,201610:46.43 A 4 `VERRY EXISTING GUNK OD 'e j 5i"+ 17560 TYLER ST NW WitTrion °"""4Do No CHANGE LAYOUT WITHOUT NOTIFICATION.IF CURB IS NEEDED IN A DIFFERENT 'VERIFY SUPPLY AND RETURN OPENINGS, 'NOTE ANY CHANGES ",uva.mna ,w,,,a ELK RIVER,MN 55330 1-4010-4005 2. CONFIGURATION CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. "(:ALL WITH ANY QUESTIONS ti CDI(76K)RIV R =�° `FAX BACK IF DRAWING IS OK AS IS a. a... " (763)391-7051 SEM E 1.24 I sr"E.: 1 or 3 IT^j v, . . COM check Software Version 4.0.8.2 Mechanical Compliance Certificate Section 1 : Project Information Energy Code:2014 Oregon Energy Efficiency Specialty Code Project Title: PRogressive RTU4 Project Type:Alteration Construction Site: Owner/Agent: Designer/Contractor: 10565 SW Nimbus CLint L Tigard,OR Latimer HVAC Clint@LatimerHVAC.com Section 2: General Information Building Location(for weather data): Tigard,Oregon Climate Zone: 4c Section 3: Mechanical Systems List Quantity System Type&Description 1 HVAC System 1 (Single Zone) : Heating:1 each-Central Furnace,Gas,Capacity=180 kBtu/h Proposed Efficiency=82.00%Et,Required Efficiency=80.00%Et Cooling:1 each-Single Package DX Unit,Capacity=122 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=11.10 EER,Required Efficiency: 11.00 EER +11.2 IEER Fan System: FAN SYSTEM 1 I RTU4--Compliance(Motor nameplate HP method) :Passes Fans: FAN 1 Supply,Single-Zone VAV,3000 CFM,3.0 motor nameplate hp Section 4: Requirements Checklist In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Requirements Specific To: HVAC System 1 : 1. Equipment meets minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) 2. Equipment meets minimum efficiency: Single Package Unit: 11.00 EER +11.2 IEER ❑ 3. Energy recovery ventilation systems. Individual fan systems that have both a design supply air capacity of 5,000 cfm or greater and a minimum outside air supply of 70 percent or greater of the design supply air quantity have an energy recovery system. Exception(s): ❑ Where energy recovery systems are prohibited by the International Mechanical Code. ❑ Systems serving spaces that are not cooled and are heated to less than 60°F. ❑ Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. ❑ Type 1 kitchen exhaust hoods. ❑ Cooling systems in climates with a 1-percent cooling design wet-bulb temperature less than 64°F(18°C). ❑ Systems requiring dehumidification that employ series-style energy recovery coils wrapped around the cooling coil when the evaporative coil is located upstream of the exhaust air stream. ❑ Systems exhausting toxic,flammable,paint exhaust,corrosive fumes,or dust. ❑ Laboratory fume hood systems that include qualifying features. Plans reference page/section: /114 Project Title: PRogressive RTU4 Report date: 09/24/18 Data filename: Untitled.cck Page 1 of 5 ❑ 4. Hot Gas Bypass Limitation.Cooling systems does not use hot gas bypass or other evaporator pressure control unless the equipment is designed with multiple steps(or continuous)capacity modulation. Plans reference page/section: f VIQ 5. Supply air economizers shall be provided on each cooling system and are capable of providing 100-percent outdoor air,even if additional mechanical cooling is required to meet the cooling load of the building.Systems provide a means to relieve excess outdoor air during economizer operation to prevent overpressurizing the building. Exception(s): ❑ Cooling equipment less than 54,000 Btu/hr total cooling capacity. Plans reference page/section: 14/1- Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Calculation of heating and cooling loads. Design loads are determined in accordance with the procedures described in the ASHRAE/ACCA Standard 183.Alternatively,design loads have been determined by an approved equivalent computation procedure. ❑ 2. Packaged Electric Equipment.Specified packaged electrical equipment has a heat pump as the primary heating source. Exception(s): ❑ Unstaffed equipment shelters or cabinets used solely for personal wireless service facilities. Li Requirement is not applicable. Plans reference page/section: 3. Equipment and system sizing.Heating and cooling equipment and systems capacity do not exceed the loads calculated in accordance with Section 503.2.1. Exception(s): ❑ Required standby equipment and systems provided with controls and devices that allow such systems or equipment to operate automatically only when the primary equipment is not operating. ❑ Multiple units of the same equipment type with combined capacities exceeding the design load and provided with controls that have the capability to sequence the operation of each unit based on load. Plans reference page/section: , . 4. HVAC Equipment Performance Requirements.Reported efficiencies have been tested and rated in accordance with the applicable test procedure.The efficiency has been verified through certification under an approved certification program or,if no certification program exists,the equipment efficiency ratings are supported by data furnished by the manufacturer. 5. Thermostatic Controls.The supply of heating and cooling energy to each zone is controlled by individual thermostatic controls that respond to temperature within the zone. Plans reference page/section: Ott-1 ❑ 6. Heat pump supplementary heat. Heat pumps having supplementary electric resistance heat have controls that,except during defrost, prevent supplementary heat operation when the heat pump can meet the heating load. Plans reference page/section: 7. Set point overlap restriction.Where used to control both heating and cooling,zone thermostatic controls provide a temperature range or deadband of at least 5°F(2.8°C)within which the supply of heating and cooling energy to the zone is capable of being shut off or reduced to a minimum. Exception(s): ❑ Thermostats requiring manual change over between heating and cooling modes. Plans reference page/section: M4 . Optimum Start Controls.Each HVAC system has controls that vary the start-up time of the system to just meet the temperature set point at time of occupancy. Plans reference page/section: . Off-hour controls.Each zone is provided with thermostatic setback controls that are controlled by either an automatic time clock or programmable control system. Exception(s): ❑ Zones that will be operated continuously. u Zones with a full HVAC load demand not exceeding 6,800 Btu/h(2 kW)and having a readily accessible manual shutoff switch. Plans reference page/section: V` 10.Shutoff damper controls.Both outdoor air supply and exhaust are equipped with not less than Class I motorized dampers. Project Title: PRogressive RTU4 Report date:09/24/18 Data filename: Untitled.cck Page 2 of 5 Exception(s): ❑ Gravity dampers shall be permitted for outside air intake or exhaust airflows of 300 cfm or less. Plans reference page/section: 44 ❑ 11.Freeze Protection and Snow melt system controls. Freeze protection systems,such as heat tracing of outdoor piping and heat exchangers,including self-regulating heat tracing,include automatic controls capable of shutting off the systems when outdoor air temperatures meet code criteria. 4�� Plans reference page/section: ❑ 12.Separate air distribution systems.Zones with special process temperature requirements and/or humidity requirements are served by separate air distribution systems from those serving zones requiring only comfort conditions;or shall include supplementary control provisions so that the primary systems may be specifically controlled for comfort purposes only. Exception(s): ❑ [503.2.4.8+]Zones requiring only comfort heating or comfort cooling that are served by a system primarily used for process temperature and humidity control. Plans reference page/section: ❑ 13.Humidity control. If a system is equipped with a means to add or remove moisture to maintain specific humidity levels in a zone or zones,a humidity control device is provided.A Plans reference page/section: �1.�=> u 14.Humidity control.Where a humidity control device exists it is set to prevent the use of fossil fuel or electricity to produce relative humidity in excess of 30 percent.Where a humidity control device is used for dehumidification,it is set to prevent the use of fossil fuel or electricity to reduce relative humidity below 60 percent. Exception(s): ❑ Hospitals,process needs,archives,museums,critical equipment,and other non-comfort situations with specific humidity requirements outside this range. Plans reference page/section: ❑ 15.Humidity control.Where a humidity control device exists it is set to maintain a deadband of at least 10%relative humidity where no active humidification or dehumidification takes place. Exception(s): ❑ Heating for dehumidification is provided with heat recovery or heat pumping and the mechanical cooling system efficiency is 10 percent higher than required in section 503.2.3,HVAC equipment performance requirements. Plans reference page/section: / 16.Ventilation.Ventilation,either natural or mechanical,is provided in accordance with Chapter 4 of the International Mechanical Code. Where mechanical ventilation is provided,the system has the capability to reduce the outdoor air supply to the minimum required by Chapter 4 of the International Mechanical Code. n Plans reference page/section: 6214✓, ❑ 17.Demand controlled ventilation(DCV). DCV is required for spaces larger than 500 ft2 for simple systems and spaces larger than 150 ft2 for multiple zone systems. Exception(s): ❑ Systems with energy recovery complying with Section 503.2.6 j Spaces less than 750 ft2(69.7 m2)where an occupancy sensor turns the fan off,closes the ventilation damper,or closes the zone damper when the space is unoccupied. Plans reference page/section: /16 ❑ 18.Kitchen hoods.Kitchen makeup is provided as required by the Oregon Mechanical Specialty Code. Exception(s): ❑ Where hoods are used to exhaust ventilation air that would otherwise be exhausted by other fan systems. ❑ Kitchen exhaust systems that include exhaust air energy recovery complying with section 503.2.6. Plans reference page/section: ❑ 19.Enclosed parking garage ventilation controls. In Group S-2,enclosed parking garages used for storing or handling automobiles employs automatic carbon monoxide sensing devices. Plans reference page/section: fiels y 20.Duct and plenum insulation and sealing.All supply and return air ducts and plenums are insulated with the specified insulation.When located within a building envelope assembly,the duct or plenum is separated from the building exterior or unconditioned or exempt Project Title: PRogressive RTU4 Report date: 09/24/18 Data filename: Untitled.cck Page 3 of 5 spaces by a minimum of R-8 insulation.All ducts,air handlers and filter boxes are sealed.Joints and seams comply with Section 603.9 of the International Mechanical Code. lception(s): When located within equipment. ❑ When the design temperature difference between the interior and exterior of the duct or plenum does not exceed 15°F(8°C). )-6 21.Low-pressure duct systems.All longitudinal and transverse joints,seams and connections of low-pressure supply and return ducts are securely fastened and sealed with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric systems or tapes installed in accordance with the manufacturer's installation instructions. Exception(s): ❑ Continuously welded and locking-type longitudinal joints and seams on ducts operating at static pressures less than 2 inches w.g. pressure classification. Plans reference page/section: ilitAlli ❑ 22.Medium-pressure duct systems.All ducts and plenums designed to operate medium-pressure are insulated and sealed in accordance with Section 503.2.7.Pressure classifications specific to the duct system are clearly indicated on the construction documents. Plans reference page/section: ❑ 23.High-pressure duct systems.Ducts designed to operate at high-pressure are insulated and sealed in accordance with Section 503.2.7. In addition,ducts and plenums are leak-tested in accordance with the SMACNA HVAC Air Duct Leakage Test Manual. Plans reference page/section: ❑ 24.Air system balancing.Each supply air outlet and zone terminal device is equipped with means for air balancing in accordance with the requirements of IMC 603.17.Discharge dampers intended to modulate airflow are prohibited on constant volume fans and variable volume fans with motors 10 horsepower. )1Plans reference page/section: ( IST) ,j 25.Manuals.The construction documents require that an operating and maintenance manual be provided to the building owner by the mechanical contractor.See long description for specifications. Plans reference page/section: °' ❑ 26.Air System Design and Control.Each HVAC system having a total fan system motor nameplate hp exceeding 5 hp meets the provisions of Sections 503.2.10.1 through 503.2.10.2. \ Plans reference page/section: 440�p 27.Allowable fan floor horsepower.Each HVAC system at fan system design conditions does not exceed the allowable fan system motor jjj"""' nameplate hp(Option 1)or fan system bhp(Option 2)as shown and calulated in requirement details. Exception(s): ❑ Hospital and laboratory systems that utilize flow control devices on exhaust and/or return to maintain space pressure relationships necessary for occupant health and safety or environmental control shall be permitted to use variable volume fan power limitation. ❑ Individual exhaust fans with motor nameplate horsepower of 1 hp or less. Plans reference page/section: d 28.Motor nameplate horsepower.For each fan,the selected fan motor is no larger than the first available motor size greater than the brake horsepower(bhp). Exception(s): ❑ For fans less than 6 bhp,where the first available motor larger than the brake horsepower has a nameplate rating within 50 percent of the bhp,selection of the next larger nameplate motor size is allowed. ❑ For fans 6 bhp and larger,where the first available motor larger than the bhp has a nameplate rating within 30 percent of the bhp, selection of the next larger nameplate motor size is allowed. Plans reference page/section: ` ❑ 29.Large Volume Fan Systems.Fan systems over 8,000(7 m3/s)cfm without direct expansion cooling coils that serve single zones reduce airflow based on space thermostat heating and cooling demand.A two-speed motor or variable frequency drive reduces airflow to a maximum 60 percent of peak airflow or minimum ventilation air requirement as required by Chapter 4 of the International Mechanical Code,whichever is greater. Exception(s): ❑ Systems where the function of the supply air is for purposes other than temperature control,such as maintaining specific humidity levels or supplying an exhaust system. Plans reference page/section: /141 i; .1.All air-conditioning equipment and air-handling units with direct expansion cooling and a cooling capacity at ARI conditions greater than or equal to 110,000 Btu/h that serve single zones have their supply fan operation controlled according to code specific requirements. Project Title: PRogressive RTU4 Report date:09/24/18 Data filename: Untitled.cck Page 4 of 5 Exception(s): D Systems where the function of the supply air is for purposes other than temperature control,such as maintaining specific humidity levels or supplying an exhaust system. Plans reference page/section: 1/144 D 31.Series fan-powered terminal unit fan motors.Fan motors for series fan-powered terminal units are electronically-commutated motors and have a minimum motor efficiency of 70 percent when rated in accordance with NEMA Standard MG 1-2006 at full load rating conditions. Plans reference page/section: 0 32.Hot Gas Bypass Limitation.For cooling systems<=240 kBtu/h,maximum hot gas bypass capacity is no more than 50%total cooling capacity. 1/11) n Plans reference page/section: 1 " Section 5: Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application.The proposed mechanical alteration project has been designed to meet the 2014 Oregon Energy Efficiency Specialty Code,Chapter 8,requirements in COMcheck Version 4.0.8.2 and to comply with the mandatory requirements in the Requirements Checklist. iii,•/ ) (A) ..‘7/1 i Name-Title Si ure D e Section 6: Post Construction Compliance Statement HVAC record drawings of the actual installation,system capacities,calibration information,and performance data for each equipment provided to the owner. HVAC O&M documents for all mechanical equipment and system provided to the owner by the mechanical contractor. Written HVAC balancing and operations report provided to th-owner. The abov post construction requirements have been co ••let-. i 9/ Of kii74/' P 10(/I PrilTcipal Mechanical Designer-Name Signature Date Project Title: PRogressive RTU4 Report date:09/24/18 Data filename: Untitled.cck Page 5 of 5 Unit Report For rtu Project: --Untitledl 09/20/2018 Prepared By: 10:43AM Unit Parameters Dimensions(ft. in.)&Weight(lb.)*** Unit Model. 48TCDD12A2A6-20000 Unit Length: _____ ___ ___ 7'4.125" Unit Size- 12(10 Tons) Unit Width: 4' 11.5" Volts-Phase-Hertz: 460-3-60 Unit Height: 4' 1.375" Heating Type: Gas ... Total Operating Weight. 1051 lb Duct Cfg- Vertical Supply/Vertical Return Low Heat *** Weights and Dimensions are approximate. Weight does Round Tube Plate Fin Coils not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size: 3/4 Condensate Drain Line Size:____ 3/4 Return Air Filter Type. Throwaway Return Air Filter Quantity: 4 Return Air Filter Size 20 x 20 x 2 Unit Configuration Medium Static Option(Belt Drive) Al/Cu-Al/Cu RTU Open Controller Temp Ultra Low Leak Economizer w/Baro Relief Standard Packaging 2-Speed indoor fan motor controlled by VFD Warranty Information (Net Price Ea.) 1-Year parts(std.) $0 5-Year compressor parts(std.) $0 10-Year heat exchanger-Aluminized(std.)_ $0 15-Year heat exchanger-Stainless Steel(std.) $0 No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity Master Price(ea.) 48TCDD12A2A6-2UOGO Rooftop Unit 1 $28,193 Base Unit $23,246 Medium Static Option(Belt Drive) $142 RTU Open controls Ultra Low Leak Temp Econo 2, baro relief-Meets $4,805 Calf.Title 24 FDD&Leak Rate 2 Speed Fan Controller (VFD) Packaged Rooftop Builder 1.49j Page 4 of 31 Certified Drawing for rtu Project: -Untitled1 • 09/20/2018 Prepared By: 10:43AM NOTES'. OUTDOOR UNITED P.O.BDX 4808 THIS DOCUMENT 1S THE PROPERTY OF CARRIER CORPORATION SUBMISSION OF THESE DRAWINGS OR DOCUMENTS UNIT J K H TECHNOLOGIES SYRACUSE,NT AND IS DELIVERED UPON TAO EXPRESS CONDITION TAUT THE DOES NOT CONSTITUTE PART PIUCUNAMCF OR 1. DIMENSIONS ARE IN INCHES, DIMENSIONS COIL TYPE CONTENTS WILL NOT BE DISCLOSED OR USED TITN THAT CARRIER IN[ I ARE IN MILLIMETERS. 41 1/4 33 15 1/8 CARRIER i5zz1 CORPORATION'S WRITTEN CONSENT. ACCEPTANCE OF CONTRACT. /8TC-A08 RTPF 2.S CENTER OF GRAVITY [tOdB] (658] !4031 48TC-A09 RIPE 49 3/8 37 v4 21 7/8CONNECTION SIZES (12531 [9161 [708] A 1 3/8" [35] DIA FIELD POWER SUPPLY HOLE 3 I.DIRECTION OF AIR FLOW /9 3/8 37(/4 15 7/6 40-3/8 48TC-Al2 ROPE (1253] [9467 [103] [1D26] B 2 1/2" [64]DIA POWER SUPPLY KNOCKOUT 487C-D08 RTPF di 1/4 33 15 3/8 C 1 3/4" [51]DIA GAUGE ACCESS PLUG [10467 [658] (4031 48TC-D09 RTPF 49 3/8 37 1/4 15 7/8 • i D 1/8" (22]DIA FIELD CONTROL WIRING HOLE [12537 19461 (403) 3/4°-14 NPT CONDENSATE DRAIN 49 3/8 37 1/4 15 7/820-3/4 E 48TC-D12 RTPF ECONOMIZER ROOD [5271 (1253] (9461 [4037 • (OPTIONAL) F 1/2"-11 NPT GAS CONNECTION 48TC-D08 RCN% 41 1/4 33 23 3/4'-14 NPT GAS CONNECTION [1048] (6581 [584.2] G 2 ' [511 DIA POWER SUPPLY KNOCK-OUT 48TC-D12 ACHE 49 3/8 37 1/4 11 ' 012531 (9461 [279.4] A` ' • �- THRU-THE-BASE CHART (FIELD INST) RIPE - ROUND TUBE. PLATE FIN (COPPER/ALUM) .^—�� NCH - NOVATION (ALUM/ALUM) • —_, • 1 • i THESE ROLES REWIRED FOR USE WITH ACCP KITS: CRUMPWROO2A01: GAS THU CURB • ��V � — 36-3/8 (2-5/8 CRBTMPWRIO4A01: GAS THRU BASEPAN III((/((�/ [925] (3211 �11 �� y RETURN AIR 4 RETURN ., _ , AIR THREADED WIRE REO'D HOLE • CONDUIT SIZE USE SIZES (MAX.) � - 1 W 1/2" ACC. 7/8" (22.21 FILTER ACCESS PANEL (TOOL-LESS) 1 �� E ALL R X 1/2° SAY 7l8" [22.21 �pX.m CONDENSATE Y 1 1/4' (002,0011 POWER 1 3/4' [44,1] r CONDENSER / \� DRAIN OPENING 283/4 COIL /�/// \1,A IN BASEPAN [73(] 37-5/8 40-3/8 I !!! 1 Z A (004) 3/4' FPT GAS 1 3/4" [44.4] TA /I 111U,11 SUPPLY [955] [10277 INDOOR COIL VTURA'" /// % SEE THRU AIR SUPPLY A (0021 PROVIDES 3/4" FPT THRU CURB ACCESS PANEL 16 -��� ` ? THE BASE AIR FLANGE d FITTING. HOLE SIZE. 2" [50.8] CHART BACK l a 691 1A 121 1,155, ?._�._ ' I355I t1 , THRU-THE-BASE CHART (FIOP) ''aa,, i 1 i !2191 -X •• • FOR "THRU-THE-BASEPAN"FACTORY OPTION, " { 1 r �l)I.J "' FITTINGS FOR ONLY X. Y, A Z ARE PROVIDED. HN L6 1/4 FOR BELOW LISTED MODELS. A FIELD -4 6-1/] SUPPLIED 1/2'ADAPTER IS REQUIRED 2751]8—� [100] HOOD 3-7/4 RH BETWEEN BASE PAN FITTING AND GAS VALVE: 14 [831 48HCD,5408 TOP 3s61 ---25-1/2 All 7 A (6471 1-1/4 45/8 (321 11-7/8 11181 [302] ELECTRICAL I---� DISCONNECT CONTROL BOX A. LOCATION ACCESS PANEL ITER CONDENSER B, ��� '' •• E STD. COIL 0 (� CONDENSATE DRAIN 1 OPTIONAL INDOOR BLOWER • OPTIONAL • FACTORY ACCESS FACTORY , 27-7/8 INSTALLED ----- INSTALLED DISCONNECT CONVENIENCE 11-- Z 17091 HANDLE 13-i/8 (70674 AjpSI DE • EF.---- -------- _ OUTLET C _ 1� 6-5/8 HANDLE�� F [331] ■ SUPPLY AIRDRAIN I ii\L_______::tr,, Th,rCCCl1�� I C6I59] 4411 (168] Y riI0() . r� . [)[) 6-1/8157 = [951 59-1/2 2-5/8- ' 4.-- 8-3/8 6-5/8 "Ill 7 [1771 6-1/8 43l8 [1510] [671 37 12147 [161] 37-7/8 [155] [1131 CURB [940] [9621ir LEFT WIDTH — 88-1/8 110758 BAROMETRIC 122387 SUPPLY t RETURN RELIEF FRONT AIR41, AIR FLOW RIGHT SHEET DATE SUPERCEOES 48TC 08-12 SINGLE ZONE ELECTRICAL REA ( OF2 03-08-10 11-24-08 COOLING WITH GAS HEAT 1 48TM500985 F Packaged Rooftop Builder 1.49j Page 5 of 31 Certified Drawing for rtu Prepared Project: gntitled1 09/20/2018 y 10:43AM UNITED P.O.BOX IROS 1X13 OOCUNCXr IS TNT PROPERTY OE CARRIER C0AP0AATI0R SU6715SIOX M iXfSE 0,%X0765 OR WCNIENi6 TECHNOLOGIES S,A4C05L,NY ANp IS DELIVERED UPON THE[RODESS C500ITION 10*1 100 ppL6 HOT CONSTINTE PRAT PEAEORMARCF OA OUTDOOR STD. UNIT CORNER CORNER CORNER CORNEA _ CONTEXTS,IIS MOT XE DISCLOSED OR USED WITHOUT CARRIER %6ccrrexc[DE 10510411. UNIT WEIGHT X WEIGHT (A1 WEIGHT IB) WEIGHT IC) WEIGHT(D) C.G. CARRIER iRRYt [ORPg1At[ONS NR1r1EX COX9CXT. COIL TYPE LBS. KG. LBS. KG. LBS. KG. LBS. KG. IBS. KG. % Y Z 48TC-A08 RIPE 780 354 178 81 158 72 209 95 236 107 41 1/2[10541 33 7/8 [860] 20 1/2 [5211 644 STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. 48TC-A09 RTPF 920 418 212 96 183 83 243 110 282 128 40 7/8[1038] 34[864] 23 1/8 [5871 FOR OTHER OPTIONS AND ACCESSORIES. REFER TO THE PRODUCT DATA CATALOG. 48TC-Al2 RTPF 930 422 216 98 196 89 247 112 272 123.5 42 [10671 33 1/8 [8411 24 1/4 [6161 48TC-008 RIPE 835 379 164 74.5 110 71,2 255 115.8 246 111.7 44 7/8 [11401 35 5/8[9051 19 3/8[4921 481C-009 RTPF 930 422 228 103.5 187 85 232 105.3 283 128.5 39 3/4 [1010) 32 7/8[8351 18 5/8[4731 48TC-012 RTPF 940 427 231 104.9 189 85.8 234 106.2 286 129.8 39 3/4[1010] 33(8387 18 1/2 14101 48TC-008 ACHE 805 365.5 160 72.6 153 69.5 240 109 260 118 43[1092] 36 3/8 1924] 20 3/8[517.71 48TC-D12 MCH% 895 406.3 185 84 176 79.9 260 118 274 124.4 42 7/8[10891 35 1/2 [902] 22 7/8 [5811 RIFT - ROUND MCAT- NOVATION BIALUMAALUNI [COPPER/ALUM] CORNER A CORNER B IIIIIIfII(�l( . NtWil ll/�i1 CORNER D CORNER C 'OP _ x v 1. = . Al z I 0 � il : Iff00 E-- O : : 0 0 g FRONT SHEET DATE SUPERSEDES 48TC 08-12 SINGLE ZONE ELECTRICAL REV 48TM500985 2oF2 03-08-10 11-24-08 COOLING WITH GAS HEAT F . Packaged Rooftop Builder 1.49j Page 6 of 31 Certified Drawing for rtu Project: -'Untitled1 09/20/2018 Prepared By: 10:43AM Service Clearance • B C11247 LOCATION DIMENSION CONDITION 48-in(1219 mm) •Unit disconnect is mounted on panel 36-In(914 mm) •If nsion-fl N 12-in(305 mm) A 18-in(457 mm) •No disconnect,convenience outlet option •Recommended service clearance(use electric screwdriver) 12-In(305 mm) •Minimum clearance(use manual ratchet screwdriver) 36-In(914 mom) •Unit has economizer 8 12-In(305 mm) •If dimension-A Is 36-i(914 mm) Special •Check for sources of flue products within 10-ft of unit freshets Intake hood 36-in(914 mm) •Side condensate drain Is used 18-in(457 mm) •MMimum clearance 48-in(1219 mm) •No flue discharge accessory fastalled,surface is combustible material 42-In(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wag,another unit) D 36-In(914 mm) •Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check far adjacent units or building fresh air intakes within 10-ft of this wilt's flue outlet NOTE:Unt not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. n.na sa. Packaged Rooftop Builder 1.49j Page 7 of 31 . . Performance Summary For rtu Project: -UnU8od1 09/20/2018 Prepared By: 10:43AM Part NuKmber:48TCDD12A2A6-2UOGO ARI EER- 11J0 |EER: 12.8 Base Unit Dimensions Unit Length. 88.1 in Unit Width. 59.5 in it H 49.4 in Operating Weight Base Unit Weight 940 lb Medium Static Option (Belt Drive). 15 lb RTU Open Controller - 2 lb Temp Ultra Low Leak Economizer w/Baro Relief 74 lb 2 Speed Fan Controller (VFD): 20 lb Total Operating Weight: 1051 lb Unit UnitVn|tmgo'Phaso'Hortz. 460-3'60 Air Discharge. Vertical Fan Drive TypeBelt Actual Airflow- 4000 CFM Site Altitude- 39 ft Cooling Performance Condenser Entering Air DB 90.0 F Evaporator Entering Air DB: 77.5 F Evaporator Entering Air WB64.3 F EnbohngAi,Entha|py- 29.41 BTU/lb Evaporator Leaving Air DB 55.1 F Evaporator Leaving Air WB 54.1 F Evaporator Leaving Air Enthalpy 22.62 BTU/lb Gross Cooling Capacity 123.03 MBH Gross Sensible Capacity 96.41 MBH Compressor Power Input- 8.27 kW Coil Bypass Factor 0.068 Mixed Air Outdoor Air Airflow 420 CFM Outdoor Air DB: 90.0 F Outdoor Air WB 67.0 F Outdoor Air Htg.Temp• 22.0 F Return Air DB 78.0 F Return Air W13- 64.0 F RetumAJrH¢l.Tomp: 78.0 F Heating Performance Heating Airflow. 4000 CFM Entering Air Temp 65.0 F Leaving Air Temp: 99.3 F Gas Heating Input Capacity: 120.0/180.0 MBH Gas Heating Output Capacity 98.V/148.o MBH Temperature Rise: 34.3 F Thermal Efficiency(%) 83.0 Supply Fan External Static Pressure. 0J5 in wg Options/Accessories Static Pressure Economizer: 0.20 in wg Packaged Rooftop Builder 149j Page 8 of 31 Performance Summary For rtu Pmject: -Untitlod1 09/20/2018 Prepared By: 10:43AM Total Application Static(ESP+ Unit Opts/Acc.) 0.95 in wg Fan RPM. 981 Fan Power 2.60 BHP NOTE: Selected IFM RPM Range: 838-1084 Electrical Data Voltage Range: 414-506 Compressor#1 RLA. 7.7 Compressor#1 LRA. 52 Compressor#2 RLA. 7.7 Compressor#2 LRA 52 Indoor Fan Motor Type:. MED Indoor Fan Motor FLA: 5.3 Combustion Fan Motor FLA(ou). 025 Power Supply MCA 24 Power Supply MOCP(Fuse or HACR) 30 Disconnect Size FLA 25 Disconnect Size LRA 147 Electrical Convenience Outlet None Outdoor Fan [Qty/FLA(oa)]. 3/0.8 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 97.9 94.7 89.0 125 Hz 94.1 87.5 83.1 250 Hz 80.8 72.4 80.5 500 Hz 74.7 67.8 78.5 1000 Hz 71.0 85.6 75.5 2000 Hz 68.4 61.3 71.6 4000 Hz 71.7 61.5 69.6 8000 Hz 73.2 59.8 69.3 A-Weighted 82.2 75.3 82.0 Advanced Acoustics G 11% '676 140 ^ . t44 �� _ 00k .13.1� Advanced Accoustics Parameters 1. Unit height above ground 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground........................... ..- 5.7 ft 4. Height of obstruction: 0.0 ft 5. HorizontaJ distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction 0.0 ft Performance Summary For rtu Project: --Untitled1 09/20/2018 Prepared By: 10:43AM Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 89.0 83.1 80.5 78.5 75.5 71.6 69.6 69.3 91.0 Lw B 62.8 67.0 71.9 75.3 75.5 72.8 70.6 68.2 81.1 LwA C 56.6 50.7 48.1 46.1 43.1 39.2 37.2 36.9 58.6 Lp D 30.4 34.6 39.5 42.9 43.1 40.4 38.2 35.8 48.7 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. FanCurve 20 N ��V -- 18 ><103 --\ \ --....1 '1\ - N `` \614 y � �LI) "34319C---- y""'", I \ �� _- { men02 -� `���_ ``NU,5081- , Q SBFT 1.O 1. CO 1 1 I 1 I L r 1 1+1 _L L__l I ',tk.l_ ! P'v I_l 1 1 , 1 1 1 co C6 12 18 24 3) 35 42 48 54 Arflow(CFM-thousands) RPM=981 BHP=2.60MaximumRPM=1400MaximumBHP=4.70 Note:Pleasecontactapplicationengineeiingforselectionsoutsidetheshadedregion. SC-SystemCurveRP-RatedPoint Packaged Rooftop Builder 1.49j Page 10 of 31 Unit Feature Sheet for rtu Project: —Untitled1 09/20/2018 Prepared By: 10:43AM Carne (;1) VireatherMakee — 48TC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 6,75,8.5,10,12.5,15 TONS STANDARD FEATURES INCLUDE: �� • Puree(R-410A)WC refrigerant ' • Single-stajeisingbracutt cooling capacity control on 07 models • Two-stageftw *#o-circcooling capacity control on 08-16 models r fs xr • Two-stage/single circuit cooling capacity control on 08,09,12 models • EER'supto11.1 j ; ,` "s • IEERsupto12,8 %� A • Energy Saving Staged Air Volume(SAW')2-speed indoor fan motor on two circuit(08-16)and 07 models.Required in U.S.installations474'7— . � Not available or required to meet DOE on 48TC°M models 08,09,12. ; • Scroll compressors with internal One break and overload protection • Acuiro"`and or TXV refrigerant metering system ,,;4 °' • Exclusive non-corrosive composite condensate pan in accordance with r ASHRAE Standard 62,sloping design,side or center drain • Standard cooling operation up to 115°F(46'C)and down to 40"F(4°C) -downto 25'F(-4'C)with winter start kit I..... • Pre-painted exterior panels and primer-coated interior panels tested to •S x 500 hours sari spray protection • ExclusiveOptional Louvered Hail Guard Shown error code designation burner control logic solid-state control tor and diagnosticswg LED design ogicenergy saving indoor fan motor delay • Induced draft gas heal combustion design • Redundant gas valves with up to two stages of treating to • Low pressure and high pressure switch protected 4 MAINTENANCE FEATURES: i { •Access panels with easy grip handles r,'I _.i j • Innovative easy starting,no-strip screws on unit access panels •Two-inch disposable return air filters and Tool-less filter access door •Central terminal board facilitating simple safety circuit troubleshooting WEATHERMAKER SERIES and simplified control box arrangement WeatherMaker(48TC)units are one-piece gas heating,electric INSTALLATION FEATURES: cooling units that are pre-wired and charged wilti Puron • Thru-the-botlom power entry capability (R-410) refrigerant. They are factory tested In both heating • Single point gas and electric connections and cooling modes, and rated in accordance with AHRI • Full perimeter base rail with built-in rigging adapters and fork slots Standard 340/360 (07-16 sizes). WeatherMaker orbits are • Field convertible from vertical to horizontal airflow for slab mounting. designed in accordance with UL Standard 1995,and listed by (16 size models require field installed supply duct cover). the Underwriters'Laboratories. STANDARD WARRANTY: • 10-year heat exchanger-15-year stainless steel option Approved and certified by: • 5-year compressor • 1-year parts • 3-year parts on Nervation Condenser coils-where available A• fl i f€Eil. • Many optional upgrades also available Us. OPTIONS INCLUDE BUT ARE NOT LIMITED TO: ""4M°"ortImare4 a • Prerrtertink"and RTU Open Muth-Protocol DDC Controls c us .`m. • Supply and Return Air Smoke Detectors,high static motors »n ,� • Louvered condenser colt guards at ogatArka,WA r x«a.W;,, • Economter,disconnect and convenience outlet options ,tt""'•°' .1 • Stainless Steel heat exchanger option • Hurnidi-Mr2e(adaptive deltuneditcation system available on ail models with RTPF condenser coils-Motor Master I controller included • Hinged access panels • Condensate overflow switch • VFD had held accessory display kit For a,xurvierte hi 154 conchs amal acct-a.r...,..r:ie+to I,e Pradtn Dam Calatog kit Oil uw. Packaged Rooftop Builder 1.49j Page 11 of 31 • OPTIONS: DIMENSIONED AND TOLERENCED PER ANSI Y14.6M-1181 REVISIONS MATERIAL: 188a.GAL STEEL REV. DESCRIPTION DATE APPROVED INSULATED PANELS (WHERE REQUIRED) Attn: Tag: . 1 INITIAL DRAWING 6/23/2006 1"DUCT INSULATION (R VALUE 3.85) 2 UPDATED TOP BRACES 11/29/11 00 GASKET PROVIDED WITH CURB 1 1/2"ADDED TO EXISTING CURB O.D. Approval: SUPPLY AIR --.-- 17 9/16" —.- �-2"TYP RETURN AIR *,'� � 1 �� 33 1/4" 361/4" EXISTING CURB LAYOUT // INSULATED -773/4" �' COVER r 751/2" .1 at 4115/16" SUPPLY I 70 7/16" ------ — — 56 1/2" V 1 RETURN 36 11116" C/!1 24 1/2" 2 1/4"—�{ -tet 21/4" I- j' 81 3/4"y 1 (:))6'/ 70 3/4" F 53 7/16" { 7" t "+ F 791/4" -I 71 15/16" CURB WEIGHT(LBS.) APPROVALS DATE TRS: 163.40 ""wE, esaunders 1-4010-4005 CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO 3'.."4"137"..- Wednesday,February 17,2016 10:46:43 AA "VERIFY EXID LING CURB 0D "m,", 17560 TYLER ST NW mE"`'IR' IOLOWTHO X0 CHANGE LAYOUT WITHOUT NOTIFICATION.IF CURB IS NEEDED IN A DIFFERENT VEERIFYSUPPLY AND RETURN OPENINGS ..�<.„ .E„7 °-""""- "NOTEANYCHANGES ELK RIVER,MN 55330 1-4U10-4 05 CONFIGURATION CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. CALL WITH ANY QUESTIONS CDI(63391-790 �6E. "FAX BACK IF DRAWING IS OK AS IS ESm"EE I (763)391.7851 SCUD 1:24 I/MEET: 1 or 3 01/1) grill 4 Physical data — 48TJ016-028 Ca«.,.iei 44 016D/E UNIT SIZE 020D 0240lE 028D/E 208/230,460 v 575 v NOMINAL CAPACITY(tons) 15 18 20 25 OPERATING WEIGHT(Ib) Unit AI/AI* 1570/ 590 1850 1850/2031 2234/2413 Al/Cu* _. 1670 1980 1980/2161 2364/2543 Cu/Cu* 17 a 50 2090 2090/2271 2474/2653 Economizer 110 110 110 110 1 Roof Curb** .,. 200 200/213 200/213 COMPRESSOR Semi-Hermetic Hermetic Semi-Hermetic Quantity 1 2 2 2 Oil(oz) 130 65 ea 1 65 ea 152 ea REFRIGERANT TYPE R-22 Operating Charge(lb-oz) i Circuit 1tt 224 15-8 15-8 16-12 Circuit 2 — 15-8 15-8 15-12 CONDENSER COIL Enhanced Copper Tubes, Aluminum Lanced or Copper Fins Rows..Total FacesA Area(sq ft) 318 9 136 I 22.2 I 22 2 I 22 2 CONDENSER FAN Propeller Type Nominal Cfm 12,000 14,200 14,200 14,200 Quantity...Diameter(in.) 2 26 2...30 2..30 2 30 Motor Hp...Rpm 1 . 1075 1 .1075 1...1075 1...1075 Watts Input(Total) 3550 3400 3400 3400 EVAPORATOR COIL Copper Tubes,Aluminum or Copper Plate Fins 4.. 15 Total Face A ea(sq ft) 316 5 3 I 17 9 f 4 154 7.9 I 17 9 EVAPORATOR FAN Centrifugal Type Quantity...Size(in.) 2...10 x 10 2...10 x 10 2 .12 x 12 2..12 x 12 2. 12 x 12 Type Drive Belt Belt Belt Belt Belt Nominal Cfm 6000 6000 7200 8000 10,000 Motor Hp 3 7 3 0 5 71/2 10 Maximum Continuous Bhp 4 25 3 45 5 90 8 7[208/230,575 v] 10 2[208/230,575 vi 9 5[460 v) 11 8[460 v) Motor Frame Size 56H 56H 184T 213T 215T Nominal Rpm High/Low — — — — — . Fan Rpm Range 1194-1526 896-1161 1047-1251 1238-1494 1323-1579 Motor Bearing Type Ball Ball Ball Ball Ball Maximum Allowable Rpm 1550 1550 1550 1550 1550 Motor Pulley Pitch Diameter Min/Max(in.) 3.4/4 4 4 0/5 0 4 9/5.9 5 4/6.4 5.8/7 0 Nominal Motor Shaft Diameter(in.) 7/6 7/8 11/8 13/s 13/8 Fan Pulley Pitch Diameter(in.) 5.2 4 9 8.4 7 9 7 9 Nominal Fan Shaft Diameter(in.) 1 3/1 6 13/16 1'/i 17/is 1 7/1 6 Belt, Quantity...Type...Length(in.) 1 ..AX .42 1 . BX 38 1 BX. .50 1 BX..50 1..BX.51 Pulley Center Line Distance(in.) 13 5-15 5 13 5-15 5 13 3-14 8 14 6-15.4 14 6-15 4 Speed Change per Full Turn of Movable Pulley Flange(rpm) 66 54 34 43 43 Movable Pulley Maximum Full Turns From Closed Position 5 5 6 6 6 Factory Setting 3.5 3 5 3 3 3 Factory Speed Setting(rpm) 1293 975 1149 1366 1451 Fan Shaft Diameter at Pulley(in.) 13/16 13/is 17/16 1 7/1 6 17/16 0 10