Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (122)
OFFICE COPY Va < to \ - \ 1 X 41"it j 1 iSCL ka I C-'(N;'.6 t,\ ‘Th 1 C k aTo: Jacob Peel Date: September 17,2018 BORA Architects From: Daniel Slavik _! 720 SW Washington Street,Suite 800 cc: V Portland,OR 97205 (503)226-1575 peel@boora.com I@boora.com Project Name: TTSD Durham Center FIECE10 Project Number: 02.17.00304 °- Subject: Digital Addressable Fire Alarm System SEP 19 2018 Y Specification Number: 283111 CITY OF TIS RD = Glumac Submittal Number: 02.18.50933 BUILDING DIVISION 0 Contractor Submittal Number: 283111-2 N Glumac has reviewed the referenced submittal(s). The contractor shall take action appropriate to the review directives and the comments provided below. The subject submittal(s) has been reviewed for general conformance with the design °' concept of the project and information in the contract documents to the extent shown. [Contractor is] [Contractor and Engineer of Record are] responsible for dimensions and quantities to be confirmed and correlated at job site; information that pertains solely to the fabrication process or to the means and methods of construction; coordination of the work of all trades; and performing all work in a safe and satisfactory manner. This review does not modify ;contractor's duty to comply with the contract documents. I # SUBMITTAL DESCRIPTION COMMENT ACTION 1 Fire Alarm Product Data �1 1)Manufacturer to be approved by owner. ✓ APPROVED AS NOTED 2)Coordinate exact location of Annunciator Panel with owner and architect. j 3)Confirm FACP with voice communication(and all associated equipment)location with AHJ. Ensure adequate space is available within main electrical room. 4)Confirm adequate batteries are provided per battery calcs runtime requirements. 5)Coordinate all fire protection monitoring/alarm connections with fire protection contractor. Manf approved by owner. 6)Ensure breaker feeding Fire Alarm equipment Peel, Bora 09018!2018 is red and capable of being locked in the"on" position. 7)Architect to confirm device color. Note: The Fire Alarm system is design/build. This submittal has been reviewed for General Conformance only and appears to be in compliance pending review by the Owner and by the Fire Marshall. Location of all devices to be reviewed by Architect. Seaitl. P0rU`anfi Reno Sacrornento Son redr.C.eco Silicon Yul(ey gas Vemi Les,Ar;yeeles Ro no Som vied /Mein Stix yooi GLUMAC.COM \'PDXDATAl Jobe\201702.17.00304 Tigard-Tualatin SD Durham Center BORA\Const Afton\Submittals\283111-2 Fire Alarm System 02.18.S09331283111-2 Fire Alarm System 02.18.S0933Aocx INTELLIKNIGHT ACCESSORY 410 SILENT 5860 Remote Annunciator KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility Now you can operate and program your IntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description • Available in red or light gray Features include an 80-character • Support for simultaneous use of backlit LCD providing easy-to- multiple 5860s understand system messages. The • RS-485 interface to panel annunciator is ergonomically • Operation and appearance is designed with over-sized buttons identical to 5860 built-in for the most frequently used annunciator x ; features, like Reset and Silence. • On-board piezo sounder audibly In addition to status messages indicates alarms, troubles, and s g displayed on the LCD, there are supervisories • Five status LEDs for alarm, five LEDs for alarm, supervisory, supervisory, trouble, silence and trouble, silence, and AC power AC power conditions status. • Wiring lengths up to 6000 ft. from 5860 The annunciator is available in gray the FACP (depending on wire Environmental to match virtually any decor and gauge and number of devices on Operating Temperature: 32°F– red for applications where the SBUS) 120°F (0°C–49°C) •annunciator must stand out. The UL listed, complies with NFPA 72 Humidity: 10% – 93% non- annunciator enclosure can be • CSFM approved condensing surface or flush mounted.A trim Electrical Specifications Compatibility ring kit is available for surface Operating Voltage: 24 VDC The 5860 is compatible with the mounting. Standby Current: 20 mA max following FACP's: Features Alarm Current: 25 mA • 5820XL Addressable Fire Control • 80-character backlit LCD display Wiring Distance: 6,000 max. from Panel (4 lines with 20 characters on FACP (depending on wire gauge • 5820XL-EVS Fire Control Panel each line) enc with Emergency Voice S stem • Tactile and audible feedback and number of devices on the 9 Y Y SBUS) • 5808 Addressable Fire Control • Accepts user codes or fire Panel fighter's key Mechanical Specifications • 5700 Addressable Fire Control • Larger keypad buttons for system Physical 9.1" W x 7.4" H x 1.5" DPanel reset and silence (23.1 W x 18.8 H x 3.8 D cm) • Install up to twelve 5860s per Shipping Weight: 2.8 lbs (1.3 kg) 5820XL/EVS or 5808 system Color • Install up to eight 5860s per 5700 5860R: Red PN 350224 Rev G system ©2014 Honeywell International Inc 5860: Gray Uz SU ,„ AL E Et41To: Jacob Peel Date: September 17,2018 BORA Architects From: Daniel Slavik 720 SW Washington Street,Suite 800 cc: VPortland,OR 97205 (503)226-1575 RECEIVED peel@boora.com Project Name: TTSD Durham Center Project Number: 02.17.00304 SEP 1 g 2018 Subject: Digital Addressable Fire Alarm System CITY OF TIGARD Specification Number: 283111 BUILDING DIVISION y Glumac Submittal Number: 02.18.S0933 Contractor Submittal Number: 283111-2 Glumac has reviewed the referenced submittal(s). The contractor shall take action appropriate to the review directives 'and the comments provided below. The subject submittal(s) has been reviewed for general conformance with the design :concept of the project and information in the contract documents to the extent shown. [Contractor is] [Contractor and Engineer of Record are] responsible for dimensions and quantities to be confirmed and correlated at job 'site; information that pertains solely to the fabrication process or to the means and methods of construction; coordination of the work of all trades; and performing all work in a safe and satisfactory manner. This review does not modify contractor's duty to comply with the contract documents. #......r SUBMITTAL DESCRIPTION ...___. REVIEW COMMENT ACTION 1 Fire Alarm Product Data 1)Manufacturer to be approved by owner. ✓ APPROVED AS NOTED 2)Coordinate exact location of Annunciator Panel with owner and architect. 3)Confirm FACP with voice communication(and all associated equipment)location with AHJ. Ensure adequate space is available within main electrical room. 4)Confirm adequate batteries are provided per battery calcs runtime requirements. 5)Coordinate all fire protection monitoring/alarm connections with fire protection contractor. Manf approved by owner. 6)Ensure breaker feeding Fire Alarm equipment J. Peel,Bora 09/18/2018 is red and capable of being locked in the"on" position. 7)Architect to confirm device color. Note: The Fire Alarm system is design/build. This submittal has been reviewed for General Conformance only and appears to be in compliance pending review by the Owner and by the Fire Marshall. Location of all devices to be reviewed by Architect. r 3[tl� Pof=arld Ret. 5dLIamor t„ San It ;i i Eincc 1 La,VEgaL Los,Arg.4.Lt; Ir+tine ti b. SFtangh1 GLUMAC.CAM \\PDXDATANobs\201TA2.17 00304 Tigard-Tualatin SD Durham Center BORA\Const Admin\Submittels1283111-2 Fire Alarm System 02.18.S0933\283111-2 F1,e Alarm System 02.18.S0933.clocz INTELLIKNIGHT ACCESSORY 44 SILENT 5860 Remote Annunciator KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility Now you can operate and program your IntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description • Available in red or light gray Features include an 80-character • Support for simultaneous use of backlit LCD providing easy-to- multiple 5860s understand system messages. The • RS-485 interface to panel annunciator is ergonomically • Operation and appearance is designed with over-sized buttons identical to 5860 built-in for the most frequently used annunciator features, like Reset and Silence. • On-board piezo sounder audibly In addition to status messages indicates alarms, troubles, and ' -_ . , ; V displayed on the LCD, there are supervisories five LEDs for alarm, supervisory, • Five status LEDs for alarm, supervisory, trouble, silence and trouble, silence, and AC power AC power conditions status. 5860 • Wiring lengths up to 6000 ft. from The annunciator is available in gray the FACP (depending on wire Environmental to match virtually any decor and gauge and number of devices on Operating Temperature: 32°F– red for applications where the SBUS) 120°F (0°C–49°C) •annunciator must stand out. The UL listed, complies with NFPA 72 Humidity: 10% –93% non- annunciator enclosure can be • CSFM approved condensing surface or flush mounted.A trim Electrical Specifications Compatibility ring kit is available for surface Operating Voltage: 24 VDC The 5860 is compatible with the mounting. Standby Current: 20 mA max following FACP's: Features Alarm Current: 25 mA • 5820XL Addressable Fire Control • 80-character backlit LCD display Wiring Distance: 6,000 max. from Panel (4 lines with 20 characters on each line) FACP (depending on wire gauge • 5820XL-EVS Fire Control Panel and number of devices on the with Emergency Voice System • Tactile and audible feedback SBUS) • 5808 Addressable Fire Control • Accepts user codes or fire Panel fighter's key Mechanical Specifications • 5700 Addressable Fire Control • Larger keypad buttons for system Physical 9.1' W x 7.4" H x 1.5" D Panel reset and silence (23.1 W x 18.8 H x 3.8 D cm) • Install up to twelve 5860s per Shipping Weight: 2.8 lbs (1.3 kg) 5820XL/EVS or 5808 system • Install up to eight 5860s per 5700 Color PN 350224 Rev G system 5860R. Red ©2014 Honeywell International Inc 5860: Gray