Loading...
Report (99) Oregon :Residential Specialty Code N1107.2 HIGH-EFFICIENCY INTERIOR.LIGHTING SYSTEM Pesmit No.: Jurisdiction: k Site mon. - Site Addr, : 1 co Sn S'--) Sk- Subdivision/Lot#: $� and/or Map and Tax Lot#: By my signature below,I certify that ami um of fifty(50)percent of the permanently installed lighting fixtures in the above mentioned building have been installed with compact or linear fluorescent,or a li ;#g source that hasa minimum efficacy of 40 lumens per input watt. (Oregon Residential Specialty Code N1107.2)1 10,0, Date 1 - 1 - •a ■r.ttor/Authorized Agent Print Name: E. A1^ G 1�� A a 5 t ORSC Section N1107.2.High-efficiency interier lighting systems. A minimum of fift (50)percent o the pen:moendy wed li .44. dell be installed with compact or linear fluorescent,or a fighting source that has a minimum efficacy of 40 lumens per't,.,xt watt. Screw-in compact fluorescent comply with this "exneant The building official shall be notified in writing at the final inspection that a minimum of fifty percent of permanently installed lighting fixtures are oompact or linear fluorescent, watt a efficacy of 40 reins per inputI Foa ttt -Fii a y enc 071014$ a Oregon Residential Specialty Code 8318.2 MOISTURE CONTENT ACKNOWLEDGE FORM the general contractor or the owner-builder at the following address: Site Address: la$'1% l Sw 5T- City: TCity: . '__ Permit#: Subdivision/Lot#: S--I and/or Map and Tax Lot#: To conform with the 2008 Oregon Residential Specialty Code(ORSC),Section R318.2 and OAR 918-480-0140,1 am notifying the building official that I am aware of the moisture content Reneat of ORSC Section R318.2 and have taken steps to meet this code [Section 8318.2 is provided for refereR3nce]. requirement. 182 Moisture Content: Prior to the:installation of interior finishes,the building official shall be notified in writing by the general contractor all moisture-sensitive wood framing members used in construction have a.moisture content of not more than 19 percent by dry weight of dry framing members. Date; 10- - 7I-N :4. r or • - L $ N-., 4:—Builder l ldingWcrma - # yes aod.doc 09125108 Oregon Residential Specialty Code R408.1 MOISTURE BARRIER ACKNOWLEDGEMENT FORM am the general contractor or the owner-builder at the following address: Site Address: loan�� S.� s ^ City: Permit#: - o� �u Subdivision/Lot#: $..� and/or Map and Tax Lot Ok To conform with the 2014 Oregon gon R esi Specialty Code(ORSC),Section R408.1 Ventilation.I am notifying the buofficial that I have installed the Moisture Barrier as per Recpirement in ORSC Section 408.1 and have taken the following steps to meet this code requirement: C ground surface of the under-floor space is covered with 6-m t black polyethylene with oixtslapped 12"at seams and »ding up the fc: afon walls 12". [ Odin( _.. lam: t 0 - \ i$ it+Pa e .5ci ,"[bra} (}r ke di►s81F .doc®f13/20I6