Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (108)
EMI NM� IlLGsocucickv MiTek� MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL15-343_UPPER Fax 916/676-1909 POLYGON The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision based on the parameters provided by Pacific Lumber&Truss Co.. Pages or sheets covered by this seal: R45642845 thru R45642860 My license renewal date for the state of Oregon is June 30,2017. Lumber design values are in accordance with ANSUTPI 1 section 6.3 These truss designs rely on lumber values established by others. •cso NGN F,2) /o 2 441 87022PE c- o N y �'a) OREGON (fl' <C// AMBER 1' �O Q`S' A. Hey- EX' E.#EX` g :06/301 i1 October 13,2015 Hernandez,Marcos The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSUTPI 1. Job Truss Truss Type Qty Ply POLYGON R45642845 PL15-343_UPPER F01 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:51:58 2015 Page 1 ID:j7axn4OsHnThIyaUAczwOszX1 UY-8NEyW14gRLFddvIFEhBm14aAVwwQ4nAz2y8K8yTrIV I 2-6-0 ] I 2-2-9 I I 1-2-0 I I 2-4-11 I Scale=1:28.6 1.5x3 II 3x5 = 1.5x3 II 3x4= 1.5x3 II 1.5x3 II 3x5 = 1.5x3 II 1 2 3 4 5 6 7 8 o OA N o e \ e e e 13 12 11 10 3x4= 3x8= 3x4= 3x4= 3x4= 10-8-1 11-4-9 I 9-11-0 1 1r 1 111-3-11 I 16-4-12 I 9-11-9 0-$ 0-7-0 5-0-3 0-7-0 0-1-8 Plate Offsets(X,V)- [10:0-1-8,Edge],(11:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.49 Vert(LL) -0.25 11-12 >783 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.64 Vert(TL) -0.40 11-12 >487 360 BCLL 0.0 Rep Stress lncr YES WB 0.56 Horz(TL) 0.05 9 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight 72 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=715/Mechanical,9=715/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2463/0,34=2463/0,4-5=-2532/0,5-6=-2532/0,6-7=-2532/0 BOT CHORD 12-13=0/1520,11-12=0/2805,10-11=0/2532,9-10=0/1515 WEBS 6-10=-316/0,2-13=1640/0,2-12=0/1018,4-12=-370/0,411=460/161,7-9=-1636/0,7-10=0/1105 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 2 cc 87022PE 9r- r- (.1")."/I4.4—.."N Nrl� wN 1) il,/ ER ‘.� �O On SER A. NER�� EXPIRES:06/30/2017 October 13,2015 1 I ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev.10/032015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not �Q a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/T911 Quality Criteria,DSB-89 and BCSI Building Component Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642846 PL15-343_UPPER F02 FLOOR 5 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:51:58 2015 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1 UY-8NEyW14gRLFddvIFEhBm14etVOMQ6mAz2y8K8yTrRV 1 1-6-0 1 1-3-4 1 10-8-3 II 2-3-0 I 1 1-2-0 I I 1-0-5 I 2-6-0 I Scale=1:27.7 1.5x3 I I 3x4= 1.5x3 I I 3x4= 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 I I 1 2 34 4 5 6 7 8 9 10 ® e o _ • o o - / N o a o es „ - o 17 • 15 14 13 12 11 3x4= 3x6 = 4x5= 3x5= 1.5x3 I I 3x4 = 3x4= 3-0-4 I 15-10-12 I 3-0-4 12-10-8 Plate Offsets(X,Y)— [7:0-1-8,Edge],[12:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.25 Vert(LL) -0.07 13-14 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.29 Vert(TL) -0.10 13-14 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.43 Horz(TL) 0.01 11 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:74 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 16=1266/0-5-8,17=-335/Mechanical,11=456/Mechanical Max Uplift17=426(LC 4) Max Gray 16=1266(LC 1),17=4(LC 3),11=457(LC 4) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=0/1294,3-4=0/750,4-5=0/750,5-6=-1002/0,6-7=-1002/0,7-8=-1099/0, 8-9=1099/0 BOT CHORD 16-17=-664/0,15-16=-1294/0,14-15=0/331,13-14=0/1099,12-13=0/1099,11-12=0/890 WEBS 3-16=-718/0,2-17=0/798,2-16=-882/0,5-14=0/737,5-15=-1177/0,9-11=-960/0, 9-12=0/379,3-15=0/856 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. ,c(cr' PROFF0 n �c\� �Z.1G1 NEER / " ' 8 • 2PE r-yr" -N V " CAj, OREGO 9° lv • PO AMBER 11 ‘O OSA. HEv" EXPIRES:06/30/2017 October 13,2015 1Mil I WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIl.7473 rev.10/032015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not �A a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642847 PL15-343_UPPER F03 Floor 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:51:59 2015 Page 1 ID:j7axn4OsHnThIyaUAczwOszX1 UY-dZoKi2iRIT6FnUyoxCQJFdkUvGo9WJBihhtbyTrlU 2-6-0 I I 2-5-1 I I 1-2-0 I I 2-4-11 Scale=1:28.9 1.5x3 II 3x5= 1.5x3 II 3x4= 1.5x3 II 1.5x3 II 3x6 = 1.5x3 II 1 2 3 4 5 6 7 8 e ///` No / a \ a e ' N o e e e e 1 12 11 10 3x4= 3x8= 3x4= 3x5= 3x4= 10-10-9 11-7-1 I 10-2-1 10.3111-5-9 11 16-7-4 I 10-2-1 0-'1-8 0-7-0 5-0-3 0-7-0 0-1-8 Plate Offsets(X,Y)— [10:0-1-8,Edge],[11:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.52 Vert(LL) -0.27 11-12 >739 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.66 Vert(TL) -0.43 11-12 >456 360 BCLL 0.0 Rep Stress Ina YES WB 0.58 Horz(TL) 0.05 9 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:73 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=725/0-4-8,9=725/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-2508/0,34=2508/0,4-5=-2587/0,5-6=-2587/0,6-7=-2587/0 BOT CHORD 12-13=0/1543,11-12=0/2877,10-11=0/2587,9-10=0/1538 WEBS 6-10=-324/0,2-13=1666/0,2-12=0/1041,4-12=-399/0,4-11=-480/168,7-9=1660/0,7-10=0/1140 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �<C0NG NEF, `SSD 2 __(4./ 870 2PE vc 7(P �cV �'Oj, OREG•N ti)Opti 9O AMBER 11 �`S A. HECk EXPI RES:06/30/2017 October 13,2015 1 t WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE IM-7473 rev.10/032015 BEFORE USE. Design valid for use only with MiTekr connectors.This design is based only upon parameters shown,and is for an individual building component,not �9 a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MITek is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BC-51 Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642848 PL15-343 UPPER F04 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 4 Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:51:59 2015 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1 UY-dZoKir2iRIT6FnUyoxCQJFdgXvD69WMJBihhtbyTrIU 2-3-0 1 1-4-11 ii 1-2-0 11 1-0-9 1 2-6-0 I Scale=1:31.6 1.5x3 II 3x6= 1.5x3 II 3x4= 1.5x3 II 3x4 = 1.5x3 II 1.5x3 II 4x5= 1.5x3 II 1 2 3 4 5 6 7 8 9 10 N • _ O _ O _ O O • 1‘.4;- i • 8O aO 15-' 15 14 13 12 11 3x4= 3x8 = 3x5= 3x4 = 4x4 = 3x4= 14-3-11 I 13-1-11 13-8-111 1 18-1-4 j 13-1-11 0-7-0 0-7-0 3-9-9 Plate Offsets(X,Y)— (12:0-1-8,Edge],[13:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.77 Vert(LL) -0.33 13-14 >663 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.84 Vert(TL) -0.51 13-14 >419 360 BCLL 0.0 Rep Stress Incr YES WB 0.60 Horz(TL) 0.06 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:81 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 16=791/0-4-4,11=791/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2635/0,3-4=-2635/0,4-5=-3446/0,5-6=-3446/0,6-7=-2477/0,7-8=-2477/0,8-9=-2477/0 BOT CHORD 15-16=0/1550,14-15=0/3254,13-14=0/3130,12-13=0/2477,11-12=0/1721 WEBS 7-13=0/354,8-12=-569/0,2-16=-1700/0,2-15=0/1191,4-15=-679/0,6-14=0/405,9-11=-1858/0,9-12=0/1092, 6-13=-860/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4��ED P R Qi �c�� ..-.v. F9 , 4c 870 2PE -N�A>, OREGO ti,�v 9C FABER '1 OSA. HEY" EXPIRES:06/30/2017 October 13,2015 t 1 a WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev.1W03/2015 BEFORE USE. Kl Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not i. a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642849 PL15-343_UPPER F05 Floor 9 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:00 2015 Page 1 ID:j7axn40sHnThtyaUAczwOszX1 UY-51MiwB2KC2bztw38MfjfrS9u5JbVuvuTQMRFP1 yTrIT 11 1-0 I 1 1-1-1 I I 1.2-0 I 2-4-15 I 2-6-0 I Scale=1:35.4 4x5= 3x4= 3x4= 3x4 = 3x4= 4x4= 3x6 FP= 3x8= 1 2 3 4 5 6 7 8 9 10 11 12 13 >1 <a IrNvXav7Nomo /® oa _ e- 26 25 24 23 22 21 20 19 18 17 3x4 = 4x6= 3x5= 3x6 FP= 3x5= 3x5 = 4x6= 3x6 = 3x5= 3x5 SP= 15-7-9 I 14-5-9 15-0-9I I 20-9-8 I 14-5-9 0-7-0 11-7-0 5-1-15 Plate Offsets(X,Y)— [12:0-1-8,Edge],[18:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.59 Vert(LL) -0.40 21 >624 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.76 Vert(TL) -0.62 21 >402 360 BCLL 0.0 Rep Stress Incr YES WB 0.84 Horz(TL) 0.08 17 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:98 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF 2400F 2.OE(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.OE(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 17=909/0-4-8,26=909/0-2-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2003/0,3-4=-2003/0,4-5=-3413/0,5-6=-3413/0,6-7=-4247/0,7-8=-4247/0, 8-9=4495/0,9-10=4495/0,10-11=-4230/0,11-12=4230/0,12-13=-3519/0, 13-14=-3519/0,14-15=-3519/0 BOT CHORD 25-26=0/1077,24-25=0/2776,23-24=0/3897,22-23=0/3897,21-22=0/4436,20-21=0/4401, 19-20=0/3519,18-19=0/3519,17-18=0/1990 WEBS 12-19=-357/0,13-18=-426/0,2-26=1375/0,2-25=0/1183,4-25=-987/0,4-24=0/813, 6-24=-618/0,6-22=0/446,15-17=-2149/0,15-18=0/1659,10-20=-272/35,11-20=-327/0, 12-20=0/1057 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)All plates are 1.5x3 MT20 unless otherwise indicated. 3)Provide mecheaioel oonneotion(by +9 f et joint(e)26.-—— -- 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �`� ,,,GINER S/O 2 'J 87022PE ter' N tN 7 SAT GREG N do <V 9O e 4I ER \\ �O �s A. Heck EXPIRES:06/30/2017 October 13,2015 i I ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev.10/03/2015 BEFORE USE. 1211. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing Mileks is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642850 PLI5-343 UPPER F06 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek industries,Inc.Tue Oct 13 08:52:01 2015 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-Zxw57X3yzMjgU4eKwMEuOgiAJi57dZUcfOAoxTyTrIS I 1-4-0 2-6-0 I 1 1.5x3 II 2 3x4= 3 1.5x3 I I Scale=1:8.7 III II N P I IP;. I I I I 111 I id g r ■M ".4 5 =' 4 3x4= 3x4= ?I-1-81 41 0 I 6-1-8 3-11-8 LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) 0.00 5 **** 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.10 Vert(TL) -0.04 4-5 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.05 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC20121TP12007 (Matrix) Weight:19 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 4-1-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=174/Mechanical,5=174/0-2-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)5. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. POs RO/ �� ,IN � /ss � � R � �� 9c-87022PE y(P 'nt N �4 OREGSN ti�OAC/ 9on �M$ER \1 �`S A. HECk EXPIRES:06/30/2017 October 13,2015 1 I erg WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTekt&connectors.This design is based only upon parameters shown,and is for an individual building component,not Ip a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall ' building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mi Ig eBk* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642851 PL15-343_UPPER F07 Floor 5 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Tue Oct 13 08:52:02 2015 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-18UTKt4akgrh6EDXU317wtFEy6GyMs8mtgwLTwyTrIR I 1-7-12 I I 1-8-15 1 1 1-2-0 11 1-4-9 1 1-6-0 1 Scale=1:30.1 3x6— 1.5x3 I I 3x4= 1.5x3 I I 3x4 = 1.5x3 I I 3x4 = 1.5x3 II 3x5= 1.5x3 I I 1 2 3x8 3 4 5 6 7 8 9 10 11 e ` a ` e ri \ / N o le ae e 19 " 17 16 15 14 13 3x4 ll 3x6= 3x8= 3x5= 3x5= 1.5x3 I I 3x4 = 3x4= I 1-10-12 2-h4 17-5-4 1 1-10-12 0-1-8 15-5-0 Plate Offsets(X,Y)— [2:0-3-0,Edqe],[8:0-1-8,Edge],[13:0-1-8,Edgej,[19:Edge,0-1-81 LOADING(psf) SPACING- 1-7-3 CSI. DEFL- in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.63 Vert(LL) -0.18 14-15 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.76 Vert(TL) -0.27 14-15 >687 360 BCLL 0.0 Rep Stress Incr NO WB 0.67 Horz(TL) 0.03 12 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:83 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing:17-18,16-17. REACTIONS. (lb/size) 18=1194/0-5-8,12=627/0-2-12 Max Gray 18=1194(LC 1),12=662(LC 4) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 1-2=0/670,2-3=-950/312,3-4=-950/312,4-5=-2192/0,5-6=-2192/0,6-7=-2379/0, 7-8=-2379/0,8-9=1741/0,9-10=-1741/0 BOT CHORD 17-18=-670/0,16-17=-32/1694,15-16=0/2387,14-15=0/1741,13-14=0/1741, 12-13=0/909 WEBS 9-13=-408/0,2-18=-808/0,1-18=-765/0,8-15=-14/787,7-15=-259/0,6-16=-295/0, 4-16=0/641,4-17=-935/0,10-12=1092/0,10-13=0/1027,2-17=0/1309 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)12. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1Od(0.131"X 3")nails. Strongbacks to be atter-had tc Itc;at Wairautx rained byakiar+neene _ 4)CAUTION,Do not erect truss backwards. 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)304 lb down at 0-1-8 on top chord. P The design/selection of such connection device(s)is the responsibility of others. p R Q 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). �\C��C.�NGIN .n LOAD CASE(S) Standard 9 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 8 I 2PE f 1-- Uniform Loads(plf) I Vert:12-19=-8,1-11=-80 Concentrated Loads(Ib) Vert:1=-304(F) y �-0j, OREGO (1 O On 9 �`y �`S BER k) A. A. Heck EXPIRES:06/30/2017 October 13,2015 4 a WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. Mil.. Design valid for use only with Wok®connectors.This design is based only upon parameters shown,and is for on individual building coponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing ;l@ ' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/1P11 Quality Criteria,DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642852 PL15-343_UPPER F08 Floor 7 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:02 2015 Page 1 ID:j7axn4OsHnThIyaUAczwOszX1 UY-18UTKt4akgrh6EDXU317wtFLO6PFMzVmtgwLTwyTrIR 2-6-0 1 0-5-10 1 1 1-2-0 I I 1-4-14 I Scale:3/4"=1' 1.5x3 I I 1.5x3 I I 1.5x3 I I 1.5x3 I I 1 23x4= 3 4 53x4= 6 ‘s= e e 0 0 , 7-- N XX e e je 10X 9 e 8 e 3x4= / \ 3x4 3x4= 3x4= I 3-1-2 3-f-10 3-9-10 1 4-4-10 4161 8-6-8 I 3-1-2 0-1- 0-7-0 0-7-0 0-1- 4-0-6 Plate Offsets(X,Y)— ]8:0-1-8,Edge],[9:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.18 Vert(LL) -0.03 7-8 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.17 Vert(TL) -0.06 7-8 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.19 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:39 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 10=370/0-2-12,7=370/0-2-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-732/0,3-4=-732/0,4-5=-732/0 BOT CHORD 9-10=0/682,8-9=0/732,7-8=0/665 WEBS 2-10=-736/0,2-9=-37/269,5-7=-718/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10,7. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 87022P� 9!' "oi, OR GON rp 0 4/ O OBER \ On A. HECk EXPIRES:06/30/2017 October 13,2015 e S WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MBI-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not I" a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights.CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642853 PL15-343 UPPER F09 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:02 2015 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-18UTKt4akgrh6EDXU317wtFL26Q_M?fmtgwLTwyTrIR I 2-6-0 I 0-5-6 I I 1-2-0I I 1-7-2 I Scale:1"=1' 11.5x3 II 2 3x4 = 31.5x3 I I 4 3x4= 51.5x3 I I J % e 0 0 N e e e 1.5x3 II KKK\ 9 8 7 6 3x4= 3x4= 3x4= I 3-0-14 3[2-¢ 3-9-6 1 4-4-6 1 6-2-8 I 3-0-14 0-1-6 0-7-0 0-7-0 1-10-2 Plate Offsets(X,Y)— [4:0-1-8,Edge],[8:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) -0.02 8-9 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.12 Vert(TL) -0.03 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(TL) 0.00 6 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:29 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 9=267/0-2-8,6=267/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-362/0,3-4=-362/0 BOT CHORD 8-9=0/423,7-8=0/362,6-7=0/362 WEBS 2-9=-456/0,4-6=-424/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)9. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ���EO P R OFeSd' ���\� �NGINEFR /O29 870 2PE yN /4'.' N '0)., OREGO tip Otv �O �MBEB "1 • �`� A. HER�P EXPIRES:06/30/2017 October 13,2015 i / WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MTek!connectors.This design is based only upon parameters shown,and is for an individual building component,riot �4 a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek° is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPII QuaMy Criteria,DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642854 PL15-343_UPPER F10 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Tue Oct 13 08:52:03 2015 Page 1 ID:j7axn40sHnThlyaUAczwOszX1UY-VK1rYC5CVzzYkOojlnHMT5nQtWc?5LTv6Kgv0MyTrIQ I 2-30I 1 1-7-11 I I 1-2-0 II 1-49 I 1-6-0 i Scale=1:26.9 1.5x3 II 3x5= 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 3x5= 1.5x3 II 1 2 3 4 5 6 7 8 9 e CI N a e a e e NV 174, 14 13 12 11 3x4 = 3x6= 3x6= 1.5x3 II 3x4= 3x4= 12-3-11 I 11-1-11 11-8-11 I I 15-5- 11-1-11 0-7-0 0-7-0 3-1-9 Plate Offsets(X,Y)— [6:0-1-8,Edge],[11:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.55 Vert(LL) -0.18 12-13 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.71 Vert(TL) -0.28 12-13 >663 360 BCLL 0.0 Rep Stress lncr YES WB 0.53 Horz(TL) 0.04 10 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:70 lb FT=0%F,0%E LUMBER- BRACING- , TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 15=673/0-4-4,10=673/0-2-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2121/0,3-4=-2121/0,4-5=-2434/0,5-6=2434/0,6-7=-1775/0,7-8=-1775/0 BOT CHORD 14-15=0/1291,13-14=0/2467,12-13=0/1775,11-12=0/1775,10-11=0/925 WEBS 7-11=-417/0,2-15=-1416/0,2-14=0/910,4-14=-380/0,5-13=-274/0,6-13=0/820,8-10=-1112/0,8-11=0/1049 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 2 �f 87022PE >'r- N � y �4>, OREG N > ti� �N �`sA. HEY's- EXPIRES:06/30/2017 October 13,2015 ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev.10/032015 BEFORE USE. Iiii. Design valid for use only with MiTekv&connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Milok is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642855 PL15-343_UPPER F11 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Tue Oct 13 08:52:03 2015 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1UY-VK1rYC5CVzzYkOojlnHMT5nVTVVIK5Qgv6Kgv0MyTrIQ I 2-6-0 10-5-10 I I 1-2-0 I I 1-6-14 Scale=1:16.4 1.5x3 II 3x4= 1.5x3 II 1.5x3 II 3x4= 1.5x3 II 1 2 3 4 5 6 e- e e 0 N e ea e e e 1 9 8 3x4= AL 3x4= 3x4= 3x4= I 3-1-2 31-10 3-9-10 j 4-4-10 416-12 8-8-8 I 3-1-2 0-1-8 0-7-0 0-7-0 0-1-8 4-2-6 Plate Offsets(X,V)- [8:0-1-8,Edge],[9:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) ldefl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.20 Vert(LL) -0.03 7-8 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.18 Vert(TL) -0.07 7-8 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.20 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:40 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=377/0-2-12,7=377/0-4-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=761/0,3-4=-761/0,4-5=-761/0 BOT CHORD 9-10=0/701,8-9=0/761,7-8=0/682 WEBS 2-10=-757/0,2-9=28/290,5-7=-737/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. •S(�ED P R OFFss ��� Nc'[NEF9 /0\9 87022PE r' N IAj, OREGO fly 4N "POAMBER A\ \p OS A. HeN) EXPIRES:06/30/2017 October 13,2015 t t ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. MITI Design valid for use only with MiTek€connectors.This design is based only upon parameters shown,and is for an individual building coponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MIlele is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642856 PL15-343_UPPER F12 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:04 2015 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1UY-zfA DIY5rGH5PLYNvbUob?IKcYwzDgoB2L_PSYoyTrIP I 2-6-0 I I 2-3-5 I I 1-2-0 11--- 2-4-11 Scale=1:28.7 1.5x3 II 3x5= 1.5x3 II 3x4 = 1.5x3 II 1.5x3 II 3x5= 1.5x3 II ' 1 2 3 4 5 6 7 8 _ e _ e e111111411114 a N 441444 - N e e 13'XX 12 11 10 3x4= 3x8= 3x4= 3x4= 3x4= 10-8-13 11-5-5 I 10-0-5 1O-0-4313 0- 13 )1-3-1311 16-5-8 10-0-5 o-1 0-7-0 5-0-3 0-7-0 0-1-8 Plate Offsets(X,Y)— [10:0-1-8,Edge],[11:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.49 Vert(LL) -0.25 11-12 >770 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.65 Vert(TL) -0.41 11-12 >478 360 BCLL 0.0 Rep Stress lncr YES WB 0.57 Horz(TL) 0.05 9 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:72 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 13=718/0-1-12,9=718/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2476/0,3-4=-2476/0,45=-2549/0,5-6=-2549/0,6-7=-2549/0 BOT CHORD 12-13=0/1527,11-12=0/2827,10-11=0/2549,9-10=0/1522 WEBS 6-10=-319/0,2-13=-1648/0,2-12=0/1025,4-12=-379/0,4-11=-466/163,7-9=-1643/0,7-10=0/1116 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)13. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ,��Eo P R QFFss Q�c\c� �c- 4-.79 XC), 8 r 2PE f r cY .v -oj, OREGO '. 4 9 F48 CEH \1 O S A. HEVN EXPIRES:06/30/2017 October 13,2015 t + WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI-7473 rev.10/032015 BEFORE USE. MI Design valid for use only with MiTek5)connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mi iT okry is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642857 PL15-343_UPPER F13 Floor 6 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:04 2015 Page 1 ID:j7axn40sHnThIyaUAczwOszX1 UY-zVVbDIY5rGH5PLYNvbUob?IKYhww3gnT2L_PSYoyTrIP I 2-3-0 I 1 1-4-11 II 1-2-0 II 1-2-5 1 2-6-0 Scale:3/8"=1' 1.5x3 II 3x6= 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 1.5x3 II 4x5 = 1.5x3 II 1 2 3 4 5 6 7 8 9 10 • o _ o _Nop. o_ e = • ctio Al. \ N adX' e e- e �Ja 15' 15 14 13 12 1Y 3x4= 3x8 = 3x5= 3x4= 4x4= 3x4= 14-3-11 I 13-1-11 13-8-111 1 18-3-8 13-1-11 0-7-0 0-7-0 3-11-5 Plate Offsets(X,Y)— 112:0-1-8,Edgel,[13:0-1-8,Edgel LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.74 Vert(LL) -0.33 13-14 >651 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.85 Vert(TL) -0.53 13-14 >412 360 BCLL 0.0 Rep Stress lncr YES WB 0.61 Horz(TL) 0.06 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:81 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 16=797/0-4-4,11=797/0-2-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2664/0,34=2664/0,4-5=-3503/0,5-6=-3503/0,6-7=-2556/0,7-8=-2556/0,8-9=-2556/0 BOT CHORD 15-16=0/1564,14-15=0/3297,13-14=0/3200,12-13=0/2556,11-12=0/1731 WEBS 7-13=0/349,8-12=-534/0,2-16=1715/0,2-15=0/1206,4-15=-695/0,6-14=-7/395,9-11=1869/0,9-12=0/1118, 6-13=-853/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)11. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6.. ,q,..'` AGNEF9 `r/0 2 4� 87022PE 9r c%j, OREGOrye 41)i 9O �c�BER \� �O �`S A. HECk EXPIRES:06/30/2017 October 13,2015 k 1 WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. 10111. Design valid for use only with M7ek0 connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642858 PL15-343_UPPER F14 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:05 2015 Page 1 ID:j7axn40sHnThIyaUAczwOszX1 UY-Rj9bzu6T1 bDGzix69CJgYWtoWKMsZ14Cae904EyTrlO 2-0.0 I I 7-10-1 I I- 1-2-0 I I 2-5-3 I Scale=1:21.0 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 1.5x3 II 1 2 3 4 5 6 3x4= 7 � � o ee e c, N o e 1 11 toe 9 8 LLL3xx4= 3x5= 3x4= 1.5x3 II 3x4= 6-2-9 1 8-9-9 19-49 I 12-0-12 8-2-9 0-7-0 0-7-0 2-8-3 Plate Offsets(X,Y)— [6:0-1-8,Edge],[10:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.42 Vert(LL) -0.14 10-11 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.49 Vert(TL) -0.21 10-11 >670 360 BCLL 0.0 Rep Stress Incr YES WB 0.33 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:54 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 12=525/0-2-8,8=525/0-1-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=1397/0,3-4=-1397/0,4-5=-1183/0,5-6=1183/0 BOT CHORD 11-12=0/887,10-11=0/1518,9-10=0/1183,8-9=0/1183 WEBS 2-12=-994/0,2-11=0/571,410=443/3,6-8=-1277/0 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)12,8. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. '<( -Ck- P R OFFss k�35 (c... 4%,.., i02 ' 87022PE 9T` N tN -7 HA2, OREGSN cy5 <U� 90 AMBER \1 �O OS A. HE-?" EXPIRES:06/30/2017 October 13,2015 a _ WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/0312015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek( is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safely Information available from Truss Plate Institute,218 N.Lee Sheet,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642859 PL15-343_UPPER FG1 FLOOR GIRDER 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MTek Industries,Inc.Tue Oct 13 08:52:06 2015 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1 UY-vnjzAE75ouL7brWljvg35jP2XjoSIpQLoluZchyTrlN 1-4-12 1-4-0 1 1.5x3 I I 2 3x4= 3 1.5x3 I I Scale=1:8.7 q , r K _ K K < k 5 4 3x4= 3x4= I 2-11-12 I 2-11-12 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/defl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.08 Vert(LL) 0.00 5 "" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.09 Vert(TL) -0.01 4-5 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.07 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:15 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 2-11-12 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=253/Mechanical,5=249/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. WEBS 2-4=-309/0,2-5=-304/0 NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)188 Ib down at 1-5-2 on top chord. The design/selection of such connection device(s)is the responsibility of others. 4)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) Vert 41.-Sr..113. 1_3.-100 Concentrated Loads(Ib) Vert:2=-188(F) � PROper, `0' G)N�FR 0, 87022PE fn <CNAj, OREGSN (yam �N AMBER "- wS A. He?` EXPIRES:06/30/2017 October 13,2015 a .e. WARNING-Verify design parameters and READ NOTES ON THOS AND INCLUDED MITER REFERANCE PAGE 1411-7473 rev.10/032015 BEFORE USE. 111 . Design valid for use only with MiTeke connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent bucking of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/D.11 Quality Criteria,DSB-89 and BCSI Building Component Safely Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R45642860 PL15-343_UPPER FG Floor Girder 2 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Beaverton,Oregon 7.530 s Jul 11 2014 MiTek Industries,Inc.Tue Oct 13 08:52:05 2015 Page 1 ID:j7axn4OsHnThIyaUAczwOszX1 UY-Rj9bzu6T1 bDGzix69CJgYWtgOKQEZKsCae904EyTrIO I 1-6-0 I 1-5-10 I I 1-2-0 I I-_ 1-4-14 I 2-6-0 I Scale:3/4"=1 1.5x3 I I 1.5x3 I I 1.5x3 I I 1.5x3 I I 1 23x4= 11 3 4 53x4= 6 e- e * -o- o l\ o N' N e e e e e 3x4= 1 9 8 3x4= 3x4= 3x4= I 3-2-10 13-9-10I 4-4-10 I 8-6-8 I 3-2-10 0-7-0 0-7-0 4-1-14 Plate Offsets(X,Y)— [8:0-1-8,Edge],[9:0-1-8,Edge] LOADING(psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.26 Vert(LL) -0.03 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.21 Vert(TL) -0.04 9-10 >999 360 BCLL 0.0 Rep Stress Inc- NO WB 0.22 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:39 lb FT=0%F,0%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=497/0-2-12,7=412/0-2-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-11=-926/0,3-11=926/0,3-4=-926/0,4-5=-926/0 BOT CHORD 9-10=0/669,8-9=0/926,7-8=0/771 WEBS 2-10=-804/0,2-9=0/327,5-7=-833/0,5-8=0/303 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10,7. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)233 lb down at 2-2-0 on top chord. The design/selection of such connection device(s)is the responsibility of others. 5)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform PR OFFS Vert:7-10=-8,1-6=-80 4\4(-\\ Concentrated Loads(lb) �� ,NG(N F9 `941 Vert:11=169(6) g7022PE 9t N �N y g. '0j, OREG N ti� QU, �QOMQER11 O �`S A. H -t ' EXPIRES:06/30/2017 October 13,2015 i ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.10/032015 BEFORE USE. P111 Design valid for use only with MTekS connectors.This design is based only upon parameters shown,and is for an individual building component.not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated b to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mitek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPII Quality Criteria,DSB-89 and BCSI Building Component Suite 109 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Symbo Is Numbering System en r Safety otes PLATE LOCATION AND ORIENTATION 1 3/" Center plate on joint unless x,y I 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property 4 I (Drawings not to scale) offsets are indicated. Dpmage or Personal Injury �ra. Dimensions are in ft-in-sixteenths. 11,74k Apply plates to both sides of truss 1 23 1. Additional stability bracing for truss system,e.g. and fully embed teeth. diagonal or X-bracing,is always required. See BCSI. TOP CHORDS 01 �� 2. Truss bracing must be designed by an engineer.For '/16 4 wide truss spacing,individual lateral braces themselves may require bracing,or alternative Tor I Allinit Q .. p bracing should be considered. 111. Aop O 3. Never exceed the design loading shown and never O 121111;a1h1 stack materials on inadequately braced trusses. 19 O 4. Provide copies of this truss design to the building For 4 x 2 orientation,locate C7 -7 I designer,erection supervisor,property owner and plates 0-'nd' from outside BOTTOM CHORDS all other interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates'on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully.Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. *Plate location details available in MiTek 20/20 NUMBERS/LETTERS. software or upon request. 8. 'Unless otherwise noted,moisture content of lumber shall not exceed 19%at time of fabrication. PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for ICC ES Reports: use with fire retardant,preservative treated,or green lumber. The first dimension is the plate 10.Camber is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311,ESR 1352,ESR 1988 responsibility of truss fabricator.General practice is to to slots.Second dimension is ER-3907,ESR 2362,ESR-1397,ESR-3282 camber for dead load deflection. the length parallel to slots. 1 1.Plate type,size,orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and in all respects,equal to or better than that , Indicated by symbol shown and/or Trusses are designed for wind loads in the plane of the specified. by text in the bracing section of the truss unless otherwise shown. 13.Top chords must be sheathed or purlins provided at output. Use T or I bracing spacing indicated on design. if indicated. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs relyon lumber values 14.Bottom chords require lateral bracing at 10 ft.spacing, BEARING established by othersg or less,if no ceiling is installed,unless otherwise noted. . 4,4". 15.Connections not shown are the responsibility of others. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint 16.Do not cut or alter truss member or plate without prior \ ©2012 MiTek®All Rights Reserved approval of an engineer. vi E§3 number where bearings occur. 17.Install and load vertically unless indicated otherwise. Min size shown is for crushing only. l® 18.Use of green or treated lumber may pose unacceptable environmental,health or performance risks.Consult with project engineer before use. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design19.Review all design ,b ,and pictures)beforeportionsof use.this Reviewing (frontpicturesackalone To k.11, words Standard for is not sufficient. Bracing. M r BCSI: Building Component Safety Information, 20.Design assumes manufacture in accordance with Guide to Good Practice for Handling, ANSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev. 10/03/2015 111111111111.1 mit MiTekC MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL 14-90U P Fax 916/676-1909 5B The truss drawing(s)referenced below have been prepared by MiTek Industries,Inc.under my direct supervision based on the parameters provided by Pacific Lumber & Truss Co.. Pages or sheets covered by this seal:R41832522 thru R41832537 My license renewal date for the state of Oregon is June 30,2015. Lumber design values are in accordance with ANSUTPI 1 section 6.3 These truss designs rely on lumber values established by others. `oNsPE �, spa 2 0 2PE z ,cv OREGON (15Q4ti R ,\ ©`S A. HARP EXPIRES:06130/2015 April 22,2014 Hernandez,Marcos The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSI/TPI 1. Mu ' MiTek� MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights,CA,95610 Telephone 916/676-1900 Re: PL14-9OUP Fax916/676-1909 5B The truss drawing(s)referenced below have been prepared by MiTek Industries,Inc.under my direct supervision based on the parameters provided by Pacific Lumber & Truss Co.. Pages or sheets covered by this seal:R41832522 thru R41832537 My license renewal date for the state of Washington is January 2,2015. Lumber design values are in accordance with ANSUTPI 1 section 6.3 These truss designs rely on lumber values established by others. 0-cONIO % vast,4--,.<!\4, 41 ` .po ,i,4,49639 W <*ttLww', April 22,2014 Hernandez,Marcos The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer,per ANSUTPI 1. Job Truss Truss Type Qty Ply 5B R41832522 PL14-90UP F01 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc.Mon Apr 21 15:39:21 2014 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1 UYcHTKdJc1 YpmObb_IRPgo7B0ohgO7S71 HOPDhOfzOQTa I 2-6-0 I I 2-2-9 1 1 1-2-0 1 1 2-4-11 Scale=1:28.8 1.5x3 II 3x5= 1.5x3 II 3x4 = 1.5x3 II 1.5x3 II 3x5 = 1.5x3 II 1 2 3 4 5 6 7 8 o ‘- 101.1.1.1.1.1.1.....—11111141111111111111111111111111114111144r - : 0 e _ N si e e i13 12 11 10 3x4= 3x8= 3x4= 3x4 = 3x4=- 10-8-1 10-8-1 11-4-9 I 9-11-9 1 1r1 111-3-1 1 16-4-12 9-115 0-14 0-7-0 5-0-3 0-7-0 0-1-8 Plate Offsets(X,Y): 110:0-1-8,Edge),111:0-1-8,Edgel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.49 Vert(LL) -0.25 11-12 >783 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.64 Vert(TL) -0.40 11-12 >487 360 BCLL 0.0 Rep Stress Incr YES WB 0.56 Horz(TL) 0.05 9 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:72 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 13=715/Mechanical,9=715/0-4-4 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. ` LIQ TOP CHORD 2-3=-2463/0,3-4=-2463/0,4-5=-2532/0,5-6=2532/0,6-7=-2532/0 Y" BOT CHORD 12-13=0/1520,11-12=0/2805,10-11=0/2532,9-10=0/15150 f?'W+�$j�r WEBS 6-10=316/0,2-13=-1640/0,2-12=0/1018,4-12=-370/0,4-11=-460/161,7-9=-1636/0,7-10=0/1105 () AG, „� W i ' NOTES � += Qyr 11 1)Unbalanced floor live loads have been considered for this design. - I 2)Refer to girder(s)for truss to truss connections. • 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to ".6,7 be attached to walls at their outer ends or restrained by other means. n- v tV LOAD CASE(S) Standard -/ONAL ��n0 PRQPess „cso 4t" 87022PE ter" nr NI 7" 0j, OREGO �o , -o' 1l$ER \\ ,<-.)�S A. HE-R � EXPIRES:06/30/2015 April 22,2014 c , ANIMS-Verify design faransetrs and READ PATES ON THIS AND INCLUDED MITER REFEREP41 PAGE NII-1413 rea(/25/2318 SWORE USE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Milt Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the �t a '* erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding WI R fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safely Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If Sauxtr:zn Pine(SP}IssuOber is spaded,tire design values are thosre effective04181/2OlS by RISC Job Truss Truss Type Qty Ply 58 R41832523 PL14-90UP F02 FLOOR 5 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:22 2014 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY4U1 igfdfJ7uFCIZU_7B2fOY183g0BcGRF3yEw5z0QTZ I 1-6-0 1 1-3-4 10 I2 I 2-30 I 1 1-2-0 I I -1-0-5 I 2-6-0 I Scale=1:27.7 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 I I 3x4= 1.5x3 I I 1 2 34x6 4 5 6 7 8 9 10 e N N...: / N e ¢ e e 17 15 14 13 12 11 3x4= 3x6 = 4x5= 3x5= 1.5x3 I I 3x4= 3x4= I 3-0-4 I 15-10-12 I 3-0-4 12-10-8 Plate Offsets(X,Y): 17:0-1-8,Edgel.112:0-1-8,Edgel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) 1/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.25 Vert(LL) -0.07 13-14 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.29 Vert(TL) -0.10 13-14 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.43 Horz(TL) 0.01 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:74 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size) 16=1266/0-5-8 (min.0-1-8),17-335/Mechanical,11=456/Mechanical Max Uplift 17=-426(LC 4) Max Gray 16=1266(LC 1),17=4(LC 3),11=457(LC 4) IONIO Vis, FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. Q§ Ov WAS'', TOP CHORD 2-3=0/1294,3-4=0/750,4-5=0/750,5-6=-1002/0,6-7=-1002/0,7-8=-1099/0, C, *ti, ,-' i vk 8-9=1099/0 '" / -1 ti BOT CHORD 16-17-66410,15-16=-1294/0,14-15=0/331,13-14=0/1099,12-13=0/1099,11-12=0/890 c ir r 'z II WEBS 3-16=718/0,2-17=0/798,2-16-882/0,5-14=0/737,5-15=-1177/0,9-11-960/0, 9-12=0/379,3-15=0/856 NOTES <1+ 49639 , . 1)Unbalanced floor live loads have been considered for this design. b riP J i E'�. 2)Refer to girder(s)for truss to truss connections. '� 3)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 426 lb uplift at joint 17. °ZONAL 4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6)CAUTION,Do not erect truss backwards. << 0) PR Ore LOAD CASE(S) Standard C4,_5 ‹tyyG(NE$.,„ ;0 870 2PE / <" - cn ,cv tv �Aj OREGON �o 141 -5.)" SER 1\ V-\...') A. Hex EXPIRES:06/30/2015 April 22,2014 s _ t WARN2 -Verify design yaram barn and READ NOTES ON THIS AND INCLUDED ICIER REFERENCE PAGE f411-7411 rex 1/29/2218 ORE USE R Design void for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. I Applicability of design parameters and proper incorporation of component a responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the �f!ek$ erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If Southern Fine tSP)barna*/is specift c tine design rabies ere those effective /O1/2OLS by A.SC Job Truss Truss Type Qty Ply 58 R41832524 PL14-90UP F03 Floor 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc.Mon Apr 21 15:39:23 2014 Page 1 ID:j7axn40sHnThIyaUAczwOszX1UY-Ygb42?eH4R06gv8gYgiHCc57kT4EwOFaTjinSYzOQTY I 2-6-0 I I 2-5-1 1 I 1-2-0 1 1 2-4-11 I Scale=1:28.9 1.5x3 II 3x5= 1.5x3 II 3x4 = 1.5x3 II 1.5x3 II 3x6 = 1.5x3 II 1 2 3 4 5 6 7 8 o e e 1' 12 11 10 3x4= 3x8= 3x4= 3x5= 3x4= 10-10-9 11-7-1 I 10-2-1 1013f9 111-5-9 I I 16-74 I 10-2-1 0-1-8 0-7-0 5-0-3 0-7-0 0-1-8 Plate Offsets(X,Y): f10:0-1-8,Edge),f11:0-1-8,Edge) LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.52 Vert(LL) -0.27 11-12 >739 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.66 Vert(TL) -0.43 11-12 >456 360 BCLL 0.0 Rep Stress Incr YES WB 0.58 Horz(TL) 0.05 9 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:73 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 13=725/0-4-8 (min.0-1-8),9=725/0-4-4 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. 'tONIO TOP CHORD 2-3=2508/0,3-4=-2508/0,45=-2587/0,5-6=2587/0,6-7=-2587/0 BOT CHORD 12-13=0/1543,11-12=0/2877,10-11=0/2587,9-10=0/1538 O OV VIAS. WEBS 6-10=-324/0,2-13=-1666/0,2-12=0/1041,4-12=-399/0,4-11=-480/168,7-9=-1660/0,7-10=0/1140 i^,,1 i, ,,,.....7.i NOTES irj {!fig' rt% i 1) 9 Unbalanced floor live loads have been considered for this design. - ' ji 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. M 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. f' ,t 49639 Y. Off, •Gi5j> LOAD CASE(S) Standard v,EO PRQp ' 870 2PE: cn ,N i y SAT OREG N 019 QZ1r 0 ksiii13ER .0 ©S A. He'ik EXPIRES:06/30/2015 April 22,2014 1 6 ®WARNING-Verily design parameter and READ PINES ON THIS AND IN1UDED MITEK REFERENCE PAGE RIF-1473 rat.1/29/2014 BEFORE USE Design valid for use only with Mitek connectors.This design is based only upon parameters shown,and is for an individual building component. 1� Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek' erector.Additional permanent bracing of the overall structure is The responsibility of The building designer.For general guidance regarding EV[ fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Carus Heights,CA,95610 If Southern Pine(S-P:Welber is wasifisd,the design values are ONUS effective /02/24113 by*LSC Job Truss Truss Type Qty Ply 5B R41832525 PL14-90UP F04 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:24 2014 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1 UY-Os9SFLfvrk8yS3it6YDWIpeEXtNnfT6kiNRL?_zOQTX 1 2-3-0 I 1 1-4-11 ii 1-2-0 II 1-0-9 j 2-6-0 1 Scale=1:31.6 1.5x3 I I 34= 1.5x3 II 3x4= 1.5x3 II 3x4 = 1.5x3 II 1.5x3 II 4x5= 1.5x3 II 1 2 3 4 5 6 7 8 9 10 00_ _Nip.. _ N00000 N O O e e e 1' ' 15 14 13 12 11 3x4= 3x8 = 3x5= 3x4 = 4x4 = 3x4= 14311 I 13-1-11 13-8-111 1 18-13 I 13-1-11 0-7-0 0-7-0 3-9-9 Plate Offsets(X,Y): f12:0-1-8,Edge),f13:0-1-8,Edgef LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.77 Vert(LL) -0.33 13-14 >663 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.84 Vert(TL) -0.51 13-14 >419 360 BCLL 0.0 Rep Stress Incr YES WB 0.60 Horz(TL) 0.06 11 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:81 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 16=791/0-4-4 (min.0-1-8),11=791/Mechanical FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. ,•VONIO TOP CHORD 2-3=-2635/0,3-4=-2635/0,4-5=-3446/0,5-6=-3446/0,6-7=-2477/0,7-8=-2477/0,8-9=-2477/0 BOT CHORD 15-16=0/1550,14-15=0/3254,13-14=0/3130,12-13=0/2477,11-12=0/1721 rWASI>.N., WEBS 7-13=0/354,8-12=-569/0,2-16=1700/0,2-15=0/1191,4-15=679/0,6-14=0/405,9-11=1858/0,9-12=0/1092, G ` /, 6-13=-860/0 r Y, '' ' °,d-_-,;:; O- y NOTES '� 1)Unbalanced floor live loads have been considered for this design. or 2)Refer to girder(s)for truss to truss connections. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4 4 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to It 4,�49639y 46y4 be attached to walls at their outer ends or restrained by other means. GISTS �" -10NALV LOAD CASE(S) Standard _ __ _ _ stk0 PRQ fi4�s 87022PE r y �'(3j, GRE (opW .Q 08ER1 � 06, A. HERD EXPIRES:06/30/2015 April 22,2014 1 WARNING-Verify design pampa fern and READ NOTES ON MIS AND PatIDED Jif 1EK REFERENCE PAGE 1411-1413 reit 1/29J2OI4 BEFORE USE Design valid for use only with Mnek connectors.This design is based only upon parameters shown,and is for an individual building component. MilL� Applicability of design parameters and proper incorporation of component b responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the M>Tekg erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TP11 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 1 td team pine(SP)lumber is cif the design vetoes use these..ffex5ive {*t/20a.s by MSC g Job Truss Truss Type Qty Ply 5B R41832526 PL14-90UP F05 Floor 9 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:26 2014 Page 1 ID:j7axn4OsHnThlyaUAczw0szX1 UY-zFGDgOgAMMOghMsFDzG_gEjdrh4P7Ju1AhwS3tzOQTV 1 1-3-0 1 1-1-1 I I 1-2-0 I I 2-4-15 I 2-6-0 I Scale=1:35.4 4x5= 3x4= 3x4 = 3x4 — 3x4— 4x4— 3x6 FP= 3x8 = 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 T7IIIII ///` ///` '1 I/ \ e I N ,i.:-�-/ N e V N a I a • �N ♦ • ° e" 26 25 24 23 22 21 20 19 18 17 3x4 = 4x6= 3x5= 3x6 FP= 3x5= 3x5 = 4x6= 3x6 = 3x5= 3x5 WB- 15-7-9 14-5-95-0-9 20-9-8 14-5-9 -7-0 6-7-0 I 5-1-15 Plate Offsets(XX): f12:0-1-8,Edge),f18:0-1-8,Edge) LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) 1/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.59 Vert(LL) -0.40 21 >624 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.76 Vert(TL) -0.62 21 >402 360 BCLL 0.0 Rep Stress lncr YES WB 0.84 Horz(TL) 0.08 17 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:98 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF 2400F 2.0E(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF 2400F 2.0E(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 17=909/0-4-8 (min.0-1-8),26=909/0-2-8 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. o'VONIO '.L' TOP CHORD 2-3=-2003/0,3-4=2003/0,4-5=3413/0,5-6=3413/0,6-7=-4247/0,7-8=-4247/0, 8-9=4495/0,9-10=-4495/0,10-11=-4230/0,11-12=-4230/0,12-13=-3519/0, 0`? o Vtf..S.Th. 13-14=3519/0,14-15=-3519/0 (') rci' ,A"'Z'' t 1 BOT CHORD 25-26=0/1077,24-25=0/2776,23-24=0/3897,22-23=0/3897,21-22=0/4436,20-21=0/4401, ^y' /r 19-20=0/3519,18-19=0/3519,17-18=0/1990 , c, cf '" Q1�, to WEBS 12-19=-357/0,13-18=-426/0,2-26=-1375/0,2-25=0/1183,4-25=-987/0,4-24=0/813, s- 6-24=-618/0,6-22=0/446,15-17=-2149/0,15-18=0/1659,10-20=-272/35,11-20=-327/0, 12-20=0/1057 ' rti 49639 NOTES ' `'OISTEs- t,(, 1)Unbalanced floor live loads have been considered for this design. S� 2)All plates are 1.5x3 MT20 unless otherwise indicated. 'IONAI. S 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)26. 4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. W W 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. x(40) PR 0p4. LOAD CASE(S) Standard �,N; ..r. — /0,, - 870 2PE r (t) y 'cj, OREG•N nn�'r,$././' ' OBER A\ `a C?S A. HER P EXPIRES:06/30/2015 April 22,2014 s N./mil%-ve,rfy design paranietrs and READ trU TES 05 MIS AND fA42tMED PIE155 REFEREN2 PAGE 511-1471 rex 1/29/2014 BEFDRE1151 Design valid for use only with MiTek connectors.The design b based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component a responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of theRNIi �� ee erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding !YI fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TP11 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 if Snurinesw Pine ISP)lumina is a u s"WTied,.the design values are shaae affective 06/111/2013 by ItLSC Job Truss Truss Type Qty Ply 58 R41832527 PL14-90UP FO6 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:26 2014 Page 1 ID:j7axn40sHnThIyaUAczwOszX1 UY-zFGDgOgAMMOghMsFDzG_gEjkKhEo7 WEl AhwS3tzOQTV 1-4-0 I 2-6-0 I 1 1.5x3 II 2 3x4= 3 1.5x3 I I Scale=1:8.7 ii 17 0 N EE 0 5 prl 4 3x4= 3x4= t1-SI 4-1-0 I 1-8 3-11-8 LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) 0.00 5 "" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.10 Vert(TL) -0.04 4-5 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.05 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:19 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 4-1-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 4=174/Mechanical,5=174/0-2-8 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES _.t,' ONIO 1)Refer to girder(s)for truss to truss connections. © QV WA- --- 41.'\\A Provide mechanical connection(by others)of truss to bearing plate at joint(s)5. G 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 6 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to Z • �1; A be attached to walls at their outer ends or restrained by other means. - y LOAD CASE(S) Standard :O 4:963....)9, "OIS'1'E 'ONALV ini � Q PR \cp NGtNE .� /p��,, ss . erp 87022P/ f 1 ctt '$..OR GUN tf'A<tr QSA. HS�- EXPIRES:06/30/2015 April 22,2014 t t WARNING-Verify design pararnetrsand READ?ETES ONDIES AND IT .tIDEf3MITERRE€€R€N:EPAG€Kid-7473 rex 1/29/2214BEFORE USE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. NI Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction Is the responsibillity of the l���g erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Qualify Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safely Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 1f Southern Pine(SP}lumber is spesifeexf,the design values are those effective 06/O1I2O9.3 by ALSC Job Truss Truss Type Qty Ply 5B R41832528 PL14-90UP F07 Floor 5 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc.Mon Apr 21 15:39:28 2014 Page 1 ID:j7axn4OsHnThlyaUAczwOszX1 UY-veOz5iiQuzeOwg0eLOlSvfozjUmsbG8Jd7PY81zOQTT 1 1-7-12 1 1 1-8-15 I 1 1-2-0 II 1-4-9 1 1-6-0 1 Scale=1:30.1 3x6= 1.5x3 I I 3x4 = 1.5x3 II 3x4 = 1.5x3 II 3x4= 1.5x3 II 3x5= 1.5x3 II 1 2 3x8= 3 4 5 6 7 8 9 10 11 e e ,../6°. - -%%41, 1 1.01°Iv .-/' 0.1 19 17 16 15 14 13 YZ 3x4 II 3x6= 3x8= 3x5= 3x5= 1.5x3 II 3x4 = 3x4= I 1-10-12 2-814 17-5-4 1 1-10-12 0.4=8 15-5-0 Plate Offsets(X,Y): 12:0-3-0,Edael,18:0-1-8,Edael,113:0-1-8,Edael.f19:Edge,0-1-81 LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.63 Vert(LL) -0.18 14-15 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.76 Vert(TL) -0.27 14-15 >687 360 BCLL 0.0 Rep Stress Incr NO WB 0.67 Horz(TL) 0.03 12 n/a n/a BCDL 5.0 Code IBC20121TP12007 (Matrix) Weight:83 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing:17-18,16-17. REACTIONS (lb/size) 18=1194/0-5-8 (min.0-1-8),12=627/0-2-12 (min.0-1-8) Max Gray 18=1194(LC 1),12=662(LC 4) 0,1ONIO FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. �S, TOP CHORD 1-2=0/670,2-3=-950/312,3-4=-950/312,4-5=-2192/0,5-6=-2192/0,6-7=-2379/0, © l� Vf ASj to j 7-8=-2379/0,8-9=-1741/0,9-10=-1741/0 C „4 `'''YQ BOT CHORD 17-18=-670/0,16-17=-32/1694,15-16=0/2387,14-15=0/1741,13-14=0/1741, y a ` d .. x �tt 12-13=0/909 is i,+ �� I WEBS 9-13=-408/0,2-18=-808/0,1-18=-765/0,8-15=-14/787,7-15=-259/0,6-16=-295/0, t� 4-16=0/641,4-17=-935/0,10-12=-1092/0,10-13=0/1027,2-17=0/1309 NOTES rt,P 4963Y4,,,,,-- •'',- 63 1)Unbalanced floor live loads have been considered for this design. O•', GIST' R 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)12. '6� Cs\'i 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. ION.ALV. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. T! 5)CAUTION,Do not erect truss backwards. 6)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)304 lb down at 0-1-8 on top chord. �d PR> F , The design/selection of such connection device(s)is the responsibility of others. ti u. 7)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). ���Co ��(y)NE- - do�9 LOAD CASE(S) Standard 87022PE t' 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) Vert:12-19=-8,1-11=-80 Concentrated Loads(Ib) ,� Vert:1=-304(F) 7 m'OJ, OREGO t)� <4, ' FABER 11 �© EXPIRES:06/30/2015 April 22,2014 i ®MithirMSS-Vestfydesignyaramearsand REAP fOTES ONMIS AND INZLI EDNIIERREFEREMXPAGENII-1473 rex 1/29/2314 BEFORE USE Design valid for use only with Mirek connectors.This design is based only upon parameters shown,and is for an individual building component. l Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek' erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and SCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 if Southern Pine OSP}!umbel Is weal/elf the 4eui)fn valves ere those effective M/01/2053 by ALM Job Truss Truss Type Qty Ply 5B R41832529 PL14-90UP F08 Floor 7 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:28 2014 Page 1 ID:j7axn4OsHnThIyaUAczwOszX1 UY-veOz5iiQuzeOwgOeLOlSvfo4nUv9bNVJd7PY81zQQTT I 2-6-0 10x10 1 1 1-2-0 1 1 1-4-14 1 Scale:3/4"=1' 1.5x3 I I 1.5x3 I I 1.5x3 II 1.5x3 II 1 23x4= 3 4 53x4= 6 00 0 0 0 % ' N e e XX e e 1C . 9 8 3x4= 3x4= ///��✓���((( 3x4= 3x4= I 3-1-2 31- 0 3-9-10 1 4-4-10 416-? 8-6-8 I 3-1-2 0-1- 0-7-0 0-7-0 0-1- 4-0-6 Plate Offsets(X,Y): 18:0-1-8,Edgel.f9:0-1-8,Edael LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.18 Vert(LL) -0.03 7-8 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.17 Vert(TL) -0.06 7-8 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.19 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:39 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 10=370/0-2-12 (min.0-1-8),7=370/0-2-8 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. oTONI© TOP CHORD 2-3=-732/0,3-4=-732/0,4-5=732/0 BOT CHORD 9-10=0/682,8-9=0/732,7-8=0/665 o� �v WASjti ' WEBS 2-10=-736/0,2-9=-37/269,5-7=-718/0 `4f NOTES � p. 1)Unbalanced floor live loads have been considered for this design. -,, i N 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10,7. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to "'`i ' be attached to walls at their outer ends or restrained by other means. '� x 1 �" ° GISMS LOAD CASE(S) Standard flNAL0 �,�Vp PRoF6- , 870 2PE p �"t> OREGO 2��N 9C 8ER11 © A. HSR. EXPIRES:06/30/2015 April 22,2014 6 i A.IYARN IMI-Verify design parame'trs and READ NOTES ON 7HISAND INCLUDED MITER REFERENCE PAGE k'7I-7473 rex 1/29/2014 DETRf'USE Design valid for use only with Mitek connectors.This design is based only upon parameters shown,and is for an individual building component. �� Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the ®, e� erector. Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding [VI fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safely Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 ff Souterern Pine SP lumber is9 ISM- sgmesRltd,the design values me these effective 05.�fl3 jzali3 by AIX Job Truss Truss Type Qty Ply 513 R41832530 PL14-90UP F09 Floor 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc.Mon Apr 21 15:39:29 2014 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-NgyL12j2fHmFYgbqv5phStLFYuG7KsvTsf96gCzOQTS I 2-6-0 1 0-5-6 I I 1-2-0 I I 1-7-2 Scale:1"=1' 11.5x3 I I 2 3x4 = 31.5x3 I I 4 3x4= 51.5x3 I I J - N CI N { p p k1.5x3 I I 9 8 7 6 3x4= 3x4= 3x4 = I -. _ _ 3-0-14 3-2-6 _- 3-9-6 1 4-4-6 1 6-2-8 I 3-0-14 1-8 0-7-0 0-7-0 1-10-2 Plate Offsets(X,Y): 14:0-1-8,Edael,18:0-1-8,Edael LOADING(psf) SPACING 1-7-3 CSI DEFL in (lac) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.17 Vert(LL) -0.02 8-9 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.12 Vert(TL) -0.03 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(TL) 0.00 6 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:29 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 9=267/0-2-8 (min.0-1-8),6=267/Mechanical FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. o^tONIO 114" TOP CHORD 2-3=-362/0,3-4=-362/0 BOT CHORD 8-9=0/423,7-8=0/362,6-7=0/362 oc7 43 WAS 'h WEBS 2-9=-456/0,4-6=-424/0 CI 14 .. .. . NOTES ,z ( u wi. Z gl 1)Unbalanced floor live loads have been considered for this design. - i 2)Refer to girder(s)for truss to truss connections. 3)Provide mechanical connection(by others)of truss to bearing plate at joint(s)9. 'r' 16 4)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. d A9� moi+' 5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to {) � I5TE ÷k` be attached to walls at their outer ends or restrained by other means. s LOAD CASE(S) Standard `�?ONALV G �;?\� C �G N4-, s, 4t- 870 2PE ter" ' �4j, OREG N el,©4 .po ' 1l SEB AN �S A. HSICk EXPIRES:06/30/2015 April 22,2014 e 1 4S mo-Ve dff design yaran#e 190 and READ NOTES Dtd THIS AND TM2JMDED MTTEK REFERENCE PAGE fif71-7473 rex 1/29/101/9EFOREUSE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. C Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibilrity of the MiTek' erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding i fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 if Southern Phase(5P}lumber is specified,the design values axe Hoose affective 0e/OII2O13 b9 ALSC Job Truss Truss Type Qty Ply 5B R41832531 PL14-90UP F10 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:30 2014 Page 1 ID:j7axn40sHnThIyaUAczwOszX1UY-rOtA WOjgQau6A_AOSoKw 4uKNIS83Cjc4JufCezOQTR I 2-30 ) 11-7-11 I I 1-2-0 11 1-4-9 1 1-6-0 1 Scale=1:26.9 1.5x3 I I 3x5= 1.5x3 I I 3x4= 1.5x3 II 3x4= 1.5x3 I I 3x5= 1.5x3 I I 1 2 3 4 5 6 7 8 9 e o 011.111111— 0 N N 0 0 - e eeXjf AM, e S� 1:� 14 13 12 11 3x4= 3x6= 3x6 = 1.5x3 II 3x4= 3x4= 12-3-11 I 11-1-11 11-8-111 1 15-5-4 I 11-1-11 0-7-0 0-7-0 3-1-9 Plate Offsets(X,Y): 16:0-1-8,Edael,111:0-1-8,Edge) LOADING(psf) SPACING 1-7-3 CSI DEFL in (lac) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.55 Vert(LL) -0.18 12-13 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.71 Vert(TL) -0.28 12-13 >663 360 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(TL) 0.04 10 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:70 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 15=673/0-4-4 (min.0-1-8),10=673/0-2-12 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. o'cONIO N, TOP CHORD 2-3=-2121/0,3-4=-2121/0,4-5=-2434/0,5-6=-2434/0,6-7=-1775/0,7-8=-1775/0 BOT CHORD 14-15=0/1291,13-14=0/2467,12-13=0/1775,11-12=0/1775,10-11=0/925 �0$ (}v VdAS WEBS 7-11=-417/0,2-15=-1416/0,2-14=0/910,4-14=-380/0,5-13=-274/0,6-13=0/820,8-10-1112/0,8-11=0/1049 A iNGi 4 NOTES > . 1)Unbalanced floor live loads have been considered for this design. N 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to ,�9 be attached to walls at their outer ends or restrained by other means. "{7 49639441 ' GISTEIL . LOAD CASE(S) Standard v4',s�ONAL' \ �O4' .4 PROFss 870 2PE "-^'Pco A� OREGO ©, 9O, �M1ER . ' N- ©S A. He 04P EXPIRES:06/30/2015 April 22,2014 WARNING-Verfy design yammers and HEAD FETES ON MIS INCLUDED MITER REFERENCE PAGE 1411-1473 sea 1/29/2014 BE4OREUV Design valid for use only with Mitek connectors.This design is based only upon parameters shown,and is for an individual building component. t4 Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek* erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/T111 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safely Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If Soutf7'•ern Pine ISM.lumber is specifsed,the design values are these.effeesire 0B/01/200 by ALS Job Truss Truss Type Qty Ply 5B R41832532 PL14-90UP F11 Floor 2 1 Job Reference(optional) Pacific Lumber 8 Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:30 2014 Page 1 ID:j7axn40sHnThIyaUAczwOszXlUY-rOWjWOjgQau6A AOSoKw_4uPzIbT3Hwc4JufCezOQTR 216-0 10-5-10 I I 1-2-0 I I 1-6-14 Scale=1:16.4 1.5x3 II 3x4= 1.5x3 II 1.5x3 II 3x4= 1.5x3 II 1 2 3 4 5 6 o- a e .. 0 0 N <44 e e e _...e - --__- - -_ - 10 9 8 3x4= 3x4=- 3x4 3x4= 3x4= I 3-1-2 31-10 3-9-10 1 4-4-10 416-R8 8-8-8 I 3-1-2 0-1- 0-7-0 0-7-0 0-1- 4-2-6 Plate Offsets(X,Y): 18:0-1-8,Edoe1,19:0-1-8,Edgel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/deft Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.20 Vert(LL) -0.03 7-8 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.18 Vert(TL) -0.07 7-8 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.20 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 (Matrix) Weight:40 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 10=377/0-2-12 (min.0-1-8),7=377/0-4-8 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. 01ONIO ,v TOP CHORD 2-3=761/0,3-4=-76110,4-5=-761/05 BOT CHORD 9-10=0/701,8-9=0/761,7-8=0/682 � V4rASjrT, r WEBS 2-10=-757/0,2-9=-28/290,5-7=-737/0 `W A.y' NOTES f `•' GY0„. Yyr ~+ e ' 1)Unbalanced floor live loads have been considered for this design. ,i 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10. ,.. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. -47 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to ',p 49639 1. be attached to walls at their outer ends or restrained by other means. 0 4f*. GiSTEVL LOAD CASE(S) Standard 4'10NAL 14GINE$. vii tZ87022PE r' pfi4jk`,1/ OR EGO ti9 NI 0 hl ER1 ©6' A. i.— EXPIRES:06/30/2015 April 22,2014 t t ®WARNIMS-Verify design yaratne lsrs and READ NOI€S ON THIS AND IMI.IIDED 14120K R€F€R€511 PAGE P111-1473 sec 1/29/2014 WORE USE Design valid for use only with M1ek connectors.This design is based only upon parameters shown,and is for an individual building component. 19 Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the 'Tete erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication,qualify control,storage,delivery,erection and bracing,consult ANSI/TPI1 Qualify Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If Fosasfreso Pine MP"Issestoos is sgesifaeaf,this design values are theca effective£5/01/2011 bg ALSC Job Truss Truss Type Qty Ply 56 R41832533 PL14-90UP F12 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:31 2014 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-JD46jkklBuOzn71DOWr9XIQW2ipMofRmJzeDk4zOQTQ 1 2-6-0 I I 2-3-5 I I 1-2-0 II 2-4-11 1 Scale=1:28.7 1.5x3 II 3x5= 1.5x3 II 3x4 = 1.5x3 II 1.5x3 II 3x5= 1.5x3 11 1 2 3 4 5 6 7 8 N / \ a e / e N e 1r0 12 11 10 3x4= 3x8= 3x4= 3x4= 3x4= 10-8-13 11-5-5 I 10-0-5 10-0113 11-3-131 I 16-5-8 1 10-0-5 0-4-8 0-7-0 5-0-3 0-7-0 0-1-8 Plate Offsets(KY): f10:0-1-8,Edgel,I11:0-1-8.Edoel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.49 Vert(LL) -0.25 11-12 >770 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.65 Vert(TL) -0.41 11-12 >478 360 BCLL 0.0 Rep Stress Incr YES WB 0.57 Horz(TL) 0.05 9 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:72 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 13=718/0-1-12 (min.0-1-8),9=718/0-4-4 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. o'tONJO i TOP CHORD 2-3=2476/0,3-4=-2476/0,4-5=-2549/0,5-6=2549/0,6-7=-2549/0 BOT CHORD 12-13=0/1527,11-12=0/2827,10-11=0/2549,9-10=0/1522 (§ Qv WASxr„ WEBS 6-10=-319/0,2-13=-1648/0,2-12=0/1025,4-12=379/0,4-11=-466/163,7-9=-1643/0,7-10=0/1116 Cj 4 NOTES 4- d U ` 4 :y; tz 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)13. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. .11 � 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to ,P 49639 £ be attached to walls at their outer ends or restrained by other means. Q &O ' ISIS ÷‘'' LOAD CASE(S) Standard `3jONAL G� EPR pfi���� S s co,..`, 'F. p �R Lv9 ,-c--- 87022PE r- / 7 ^<j, OREGON (1 4/N O FM$ER 1', On 4. HERD EXPIRES:06/30/2015 April 22,2014 f t W4RNTNG-VedffdesignyarameleisandREADNOTESONTHISANDIM2JJDEDNTTEJ(REFEREI PAGE t1f-1473Ian i.;29/2016MFDR.EiSE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown Mil is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek* erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fabrication.quality control,storage,delivery,erection and bracing,consult ANSI/TP11 Quailly Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safely Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If Ncsetf'axn Fuse Our r lumber is specified,the designs ssek eu ase these effective 04:/0112013 by ALSO Job Truss Truss Type Qty Ply 5B R41832534 PL14-90UP F13 Floor 6 1 Job Reference(option_I) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:32 2014 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-nPeUx4IxyC8gPHKPaDNO3Vzcx55RX5zvYcNmHWzOQTP 1 2-3-0 I 1 1-411 ii 1-2-0 II 1-2-5 1 2-6-0 I Scale:3/8"=1' 1.5x3 I I 3x6= 1.5x3 I I 3x4= 1.5x3 I I 3x4= 1.5x3 I I 1.5x3 I I 4x5 = 1.5x3 I I 1 2 3 4 5 6 7 8 9 10 0 et o e e e e `p 10 15 14 13 12 3x4= 3x8= 3x5= 3x4= 4x4= 3x4= 14-3-11 I 13-1-11 13-8-111 1 18-3-0 I 13-1-11 0-7-0 0-7-0 3-11-5 Plate Offsets(X,Y): 112:0-1-8,Edge),113:0-1-8,Edgel LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.74 Vert(LL) -0.33 13-14 >651 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.85 Vert(TL) -0.53 13-14 >412 360 BCLL 0.0 Rep Stress Incr YES WB 0.61 Horz(TL) 0.06 11 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:81 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 16=797/0-4-4 (min.0-1-8),11=797/0-2-12 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. 010NIO ` ' TOP CHORD 2-3=-2664/0,3-4=-2664/0,4-5=-3503/0,5-6=-3503/0,6-7=-2556/0,7-8=-2556/0,8-9=-2556/0 BOT CHORD 15-16=0/1564,14-15=0/3297,13-14=0/3200,12-13=0/2556,11-12=0/1731 ©=a 01'WAS-14 ,7r y, WEBS 7-13=0/349,8-12=-534/0,2-16=-1715/0,2-15=0/1206,4-15=-695/0,6-14=-7/395,9-11=-1869/0,9-12=0/1118, C '-, , 'VQ 1 6-13=853/0 , '' �e i NOTES ,z co 4.`i c N 1)Unbalanced floor live loads have been considered for this design. y. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)11. ' 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 4 Recommend 2x6 strop backs,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3" nails. Strop backs to 496 be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard �'� 'ONALV � �,�'�" PROi �c�ca �NG)NEF'7 /©f. 87022PE <' firie N N. y �^j, OR EGO 2� 4t/ o OS A. HERD EXPIRES:06/30/2015 April 22,2014 c r WARNINI-Verify design paramef rs and READ?CIES ON THIS AND IN6IiDE0 MIIER REFEREN:f PAGE MII-7473 re c 5/25/2014 55508EUSE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. Mil' Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding MiTek ' fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street.Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 If Southern Pine(SP}+somber is riles€ieS,the deign susses are these effective /01/2613 ffiq ALSO Job Truss Truss Type Qty Ply 5B R41832535 PL14-90UP F14 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:33 2014 Page 1 ID:j7axn40sHnThlyaUAczwOszX1 UY-FbBs8QmZjVHh1 RubBxudcj Wsm VXEGcZ3nG7JpzzOQTO I 2-0-0 I I 1-10-1 I I 1-2-0 1 1 2-5-3 I Scale=1:21.0 1.5x3 II 3x4= 1.5x3 II 3x4= 1.5x3 I I 1.5x3 I I 1 2 3 4 5 6 3x4= 7 e o i 0- a N e e e e 0 1.:. 11 10 e 9 8k 3x4= 3x5= 3x4= 1.5x3 II 3x4= I 8-2-9 1 8-9-9 1 9-4-9 1 12-0-12 I 8-2-9 0-7-0 0-7-0 2-8-3 Plate Offsets(X,Y): f6:0-1-8,Edoel,110:0-1-8,Edael LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) Vdefl Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.42 Vert(LL) -0.14 10-11 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.49 Vert(TL) -0.21 10-11 >670 360 BCLL 0.0 Rep Stress Ina- YES WB 0.33 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:54 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 12=525/0-2-8 (min.0-1-8),8=525/0-1-12 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. ` 'tONIO' " TOP CHORD 2-3=1397/0,3-4=-1397/0,4-5=-1183/0,5-6=1183/0 BOT CHORD 11-12=0/887,10-11=0/1518,9-10=0/1183,8-9=0/1183 © 0-041AS?r> WEBS 2-12=-994/0,2-11=0/571,4-10=-443/3,6-8=-1277/0 (j A. _ 10 ' 4 NOTES 40 lv �Z, 1)Unbalanced floor live loads have been considered for this design. _,;1 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)12,8. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. r 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to d 49639 �' be attached to walls at their outer ends or restrained by other means. {7GIST£R 44v N. LOAD CASE(S) Standard 'S''ONALVS CS '<C_0 PRQFes cN Q 802PE /9f to y �'j, OR EGO 2f 4<t 90 cc' BER \\ os A. HE?`•‘'' EXPIRES:06/30/2015 April 22,2014 t WARNING-Verify design pamme trs and READ?OTESON THIS AND INCLUDED MIIElf REFERENCE PAGE MEI-1473 re&//2g/202d 9£,=0R£USE Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. I9 Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding IYIE�ek= fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandra,VA 22314. Citrus Heights,CA,95610 If Souther::..pure(SP}lucisb 0-r is spin/flied,the design values nae ureas afteztloe O6/0212O53 bi.AL5C Job Truss Truss Type Qty Ply 5B R41832536 PL14-90UP FG1 FLOOR GIRDER 1 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:34 2014 Page 1 ID:j7axn40sHnThIyaUAczwOszX1UY-kolEMlnBUpPYebTohePs8w26nvzq?7vC?wstLPzOQTN 1-4-12 1-4-0 I 1 1.5x3 II 2 3x4= 3 1.5x3 II Scale=1:8.7 0 ' N L t 5 4 3x4= 3x4= I 2-11-12 I 2-11-12 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.08 Vert(LL) 0.00 5 `•" 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.09 Vert(TL) -0.01 4-5 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.07 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:15 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 2-11-12 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 4=253/Mechanical,5=249/Mechanical FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. WEBS 2-4=309/0,2-5=304/0 `,cONIO T,, NOTES ©d3 WAS t)Refer to girder(s)for truss to truss connections. G G'�y, 2)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. C;} 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to o ,,, 1, N be attached to walls at their outer ends or restrained by other means. -,-I 4)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)188 lb down at 1-5-2 on top chord. The design/selection of such connection device(s)is the responsibility of others. 4 5)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). ?+� 49639 ,zi� ° Grs'1 LOAD CASE ,S) Standard '6 \ 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 'ZONALV" Uniform Loads(plf) Vert:4-5=-10,1-3=-100 Concentrated Loads(Ib) Vert:2=-188(F) (} PRQp�� ' 87022PE r NI y cc' 1-.OREGO �o 4/ A. HER EXPIRES:06/30/2015 April 22,2014 e r V/AR ,NG-Ver4fydesignpararnelrsandREADNOTESONTNISANDINC1,tI3EDMITERREFERENCEPAGEMII-7473rec 1/29/2018 BEFORE USE Design valid for use only with Mitek connectors.This design is based only upon parameters shown,and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of theRNI= �' e kg erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding !Y' fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safely Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 if Southern Fine$1111 h robes 11 specified clue ensign values am those efe ve 0:641J2GLS my:MSC Job Truss Truss Type Qty Ply 5B R41832537 PL14-90UP FG Floor Girder 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Lake Oswego,Oregon 7.510 s Jan 13 2014 MiTek Industries,Inc. Mon Apr 21 15:39:33 2014 Page 1 ID:j7axn40sHnThlyaUAczwOszX1UY-FbBs8QmZjVHhlRubBxudcjWuGVbcGeL3nG7JpzzOQTO 1-6-0 I 1-5-10 I I 1-2-0 I I 1-4-14 I 2-6-0 Scale:3/4"=1' 1.5x3 II 1.5x3 II 1.5x3 I I 1.5x3 II 1 23x4= 11 3 4 53x4= 6 0 a 1Ci 9 6 e3x4 = L� 3x4= 3x4= 3x4= I 3-2-10 1 3-9-10 1 4-4-10 1 668 I 3-2-10 0-7-0 0-7-0 4-1-14 Plate Offsets(XX): 18:0-1-8,Edoe1,19:0-1-8,Edge) LOADING(psf) SPACING 1-7-3 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.26 Vert(LL) -0.03 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber Increase 1.00 BC 0.21 Vert(TL) -0.04 9-10 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.22 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC2012/TP12007 (Matrix) Weight:39 lb FT=0%F,0%E LUMBER BRACING TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except BOT CHORD 2x4 DF No.1&Btr(flat) end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 10=497/0-2-12 (min.0-1-8),7=412/0-2-8 (min.0-1-8) FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. 010Nro N, TOP CHORD 2-11=-926/0,3-11=-926/0,3-4=-926/0,4-5=-926/0 BOT CHORD 9-10=0/669,8-9=0/926,7-8=0/771 O, 43-f WASj WEBS 2-10=-804/0,2-9=0/327,5-7=-833/0,5-8=0/303 Q NOTES ' . 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)10,7. 3)This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. ' 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to dlt kf' be attached to walls at their outer ends or restrained by other means. {\<,,,.,,....49639,5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)233 lb down at 2-2-0 on top chord. �' ISTE 4ti The design/selection of such connection device(s)is the responsibility of others. '40NAL'. 6)In the LOAD CASE!Cl ser-tion-joadc annlied ta_the face nf_the trus&arp notes a<froDt.,4E hack-(g), LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 0Q PROF sS Uniform Loads(plf) Q+ p Vert:7-10=-8,1-6=-80 . �NGINE6- f� Concentrated Loads(Ib) '4 Vert:11=-169(B) 870 2PE <' N rN �Aj ©REG N 2� w4 1.) k)14 8ER \\ N''' A. HER EXPIRES:06/30/2015 April 22,2014 t t ®W4ANDE-Verfy design parameters and READ NOTES ON THIS AND matzo WSf7€K R€F€R€?C1 PAGE NII-1473 mx 1/29/2034 BEMfi£US€ Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. NI � Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the �° � erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding fie(Re e fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPIT Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane,Suite 109 Safety Information available from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA,95610 if 5autirrsa Fine(SN)lumber is apesified,the design vafues are t1seue affective /0€{2013 byALSC Symbols i U SystemGeneral et Notes PLATE LOCATION AND ORIENTATION 1 3/4 Center plate on joint unless x,y offsets are indicated. I 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property I (Drawings not to scale) Damage or Personal Injury rail Dimensions are in ft-in-sixteenths. 1114k Apply plates to both sides of truss 1 23 1. Additional stability bracing for truss system,e.g. and fully embed teeth. diagonal or X-bracing,is always required. See BCSI. TOP CHORDS 01 „ 2. Truss bracing must be designed by an engineer.For '/164 wide truss spacing,individual lateral braces themselves p may require bracing,or alternative Tor I MIIIr _EM O IlL1111111rdli p bracing should be considered. F , O tel Oz 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 12 O 4. Provide copies of this truss design to the building For 4 x 2 orientation,locate C7.8 - , designer,erection supervisor,property owner and plates 0-Ins' from outside BOTTOM CHORDS all other interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully.Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from *Plate location details available in MITek 20/20 CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. NUMBERS/LETTERS. 8. Unless otherwise noted,moisture content of lumber software or upon request. shall not exceed 19%at time of fabrication. PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for use with fire retardant,preservative treated,or green lumber. ICC-ES Reports: The first dimension is the plate 10.Camber is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311,ESR 1352,ESR 1988 responsibility of truss fabricator.General practice is to to slots.Second dimension is ER-3907,ESR-2362,ESR-1397,ESR-3282 camber for dead load deflection. the length parallel to slots, 11.Plate type,size,orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and Southern Pine lumber designations are as follows: in all respects,equal to or better than that / Indicated by symbol shown and/or SYP represents values as published specified. bytext in the bracingsection of the by AwC in the 2005ro012 NDS SP represents ALSC approved/new values 13.Top chords must be sheathed or purlins provided at output. Use T or I bracing with effective date of June 1,2013 spacing indicated on design. If indicated. 14.Bottom chords require lateral bracing at 10 ft.spacing, or less,if no ceiling is installed,unless otherwise noted. BEARING �� 15.Connections not shown are the responsibility of others. Indicates location where bearings )supports) occur. Icons vary but 16.Do not cut or alter truss member or plate without prior ©2012 MiTek®All Rights Reserved approval of an engineer. reaction section indicates joint ( number where bearings occur. 17.Install and load vertically unless indicated otherwise. ® 1 Min size shown is for crushing only. MIMI IBM MI0 18.Use of green or treated lumber may pose unacceptable environmental,health or performance risks.Consult with Industry Standards: project engineer before use. ANSI/TPI1: National Design Specification for Metal 19.Review all portions of this design(front,back,words Plate Connected Wood Truss Construction. and pictures)before use.Reviewing pictures alone DSB-89: Design Standard for Bracing. is not sufficient. BCSI: Building Component Safety Information, MiTeka' 20.Design assumes manufacture in accordance with Guide to Good Practice for Handling, ANSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev.01/29/2013 40'0• 11=11' GARAGE RICHT 1e ' 3R il• ns4 .ERRLIRR4q > > AR1 - ' ----1- ASJ1 - — ASJ1 / ASJ2 / / • 6:12 AH1(2) z_ AI-12 AH3 — AH4C AH5C AH6 AH7 ® \ \A1 (4) AI-17 at AH6 6:12 6:12 Ar - AM BH3 Bit 6:1 t RN1-(-)9 D2 (2) (3)g•1� 6:12 Dl 6:12 N•mem �� ■ , ` CONFORMS TO DESIGN CONCEIT cy � to 8 / / :1 t 8:14a ❑ CONFORMS TO DESIGN CONCEgWIT#- G1 v _ REVISIONS AS SHOWN —I_ C NON-CONFORMING-REVISE AND b ubMIT ❑X CONFORMS TO DESIGN CONCEPT p1 ©CONFORMS TO DESIGN CONCEPT WITH v� 20 I 7.:ER,SHOPRASIINGHASBEEJRV EW DFCHGENERAL CONFORI.A10EREVISIONSNOTED LV-1THEO:DI TI9NCONOFPTON' AND DUESNOT RELIEVE THE©NON-CONFORMING REVISE&RESUBMIT 91� ICATORl'„JDOR OF RESPON5B:L.TVFOBCONFORJANCE';ITHe N DRAJ S AND SPECIFIC T .S ALL OF WHICH HAVE PRIORITY AS.D [1 -iIS ..,,. DRA!;I'JG. C,^,H RA OR .4�i. 'ERI=H ALL DIf�1ER<SICNS. x;W s..0 x ,.a� e;_o=WHS.r.,._PR 4Cff1� By Alexia Fukw Bate B/22/ia v By: Todd R. Eaton Date: September 19, 2014 MILBRANDT ARCHITECTS CT ENGINEERI ©NMightCompuTrusInc.2006 BUILDER: ISSUE DATE: ABOVE PLAN PROVIDED FOR TRUSS POLYGON NW 03/31/14 TLACEMENT ONLY.REFER TO RUSS CALCULATIONS AND PROJECT TITLE: REVISION-I: ENGINEERED STRUCTURAL DRAWINGS FOR ALL FURTHER i' PLAN 5-B COFFER INFORMATION.BUILDING 1 6:1, um er DESIGNER/ENGINEER OF RECORD I kt. PLAN: DRAWN BY:JP REVISION-2: RESPONSIBLE FOR ALL NON-TRUSS TO TRUSS CONNECTIONS.BUILDING 5 / B CHECKED BY: DESIGNER/ENGINEER OF RECORD TO tat TRUSS REVIEW AND APPROVE OF ALL COMPANY DELIVERY LOCATION: SCALE: REVISION-3: DESIGNS PRIOR TO CONSTRUCTION. 1/8"= 1' All designs are property of-Pacific Lumber and Truss. All designs are null and void if not fabricated by-Pacific Lumber and Truss. r 40'-0' GARAGE LEFT I- 11'41' pm I I I - -- AS I ASJ1 ASJ2 _ , 040 /�6:12 ASJ2 110° AHI (2) � AH2 AHSC AH6 ■ Al (4) er U AH7 z • 6:12 ' ' 6:12 AM BH3 RH2 BH1 (2) 6:12 6:12 I R•12 \E2 (3', / H ., _ -Cr. lei )NFORMS TO DESIGN CONCEPT ; 112 I, _=_T I i I, f� C N(FORMS TO, [D�+E'SI�G�DESIGN CONCEPT WITH/y�1 /1�/ -ro 'iii t REVISIONS AS Sh OWN 6N�1f2 a� -I QX CONFORMS TO DESIGN CONCEPT nNON CONFORMI G-REVISE AND RESUBMIT v 0 CONFORMSTO DESIGN CONCEPT WITH y REVISIONS NOTED THIS SHOP DRAWING HAS BEEN REVIEWED FOR GENERAL CONFORMANCEI a� 0 NON-CONFORMING—REVISE&RESUBMIT WITH THE DESIGN CONCEP. OhFYAND DOES NOT RELIEVE THE CMS SHOP BRAVING HAS V a-i..-vvCONFOEM,OE FABRICATORNENDOR OF RESPIISIBILITY FOR CONFORMANCE WITH THE < OF RESBONS,BIL,FORCONFORMANCE VP i DES. DESIGN DRAI'INuS AND SPECIFICATIONS ALL OF WHICH HAVE PRIORITY -06VE Fr Fa , w w OVER THIS SHOP DRAWING. UF,ArTnr+C.AS I Irt✓T-1 Q HEAISIQEN By Alexia F k r Date 9/22/14 By: Todd H. Eaton Date: September 19, 20'4 MILBRANDT ARCHITECTS CT ENGINEERING INC ©Copyright CompuTrus Inc.2006 BL r,DO.. ISOUE DATE: ABOVE PLAN PROVIDED FOR TRUSS POLYGON NW 03/31/14 PLACEMENT NLY.REFER TO TRUSS CALCULATIONS AND ENGINEERED STRUCTURAL • PROJECTPLAN 5-B REVISION-1:ODRGNERIE GE1EERFOR F FURTHER INFORMATION.BUILDING COFFER DESIGNER/ENGINEER OF RECORD 1 �USS ` PLAN: DRAWN BY:JP REVISION-2: TO TRUSS CON ECTIONS.BUIRESPONSIBLE FOR LLLDING 5 B CHECKED BY: DESIGNER/ENGINEER AND OF ARD TO RDD ' 1 t' 6 TS iCOMPANY DELIVERY LOCATION: SCALE: REVISION-3: DESIGNS PRIOR TO CONSTRUCTION. 1 V 7 1/8"= 1' All designs are property of-Pacific Lumber and Truss. All designs are null and void if not fabricated by-Pacific Lumber and Truss. MiTek USA, Inc. i CompuTrus Software Warnings & General Notes WARNINGS: 1. Builder and erection contractor should be advised of all General Notes and Warnings before construction commences. 2. 2x4 compression web bracing must be installed where shown+. 3. Additional temporary bracing to insure stability during construction is the responsibility of the erector.Additional permanent bracing of the overall structure is the responsibility of the building designer. 4. No load should be applied to any component until after all bracing and fasteners are complete and at no time should any loads greater than design loads be applied to any component. 5. CompuTrus has no control over and assumes no responsibility for the fabrication,handling,shipment and installation of components. 6. This design is furnished subject to the limitations set forth by TPI/WTCA in BCSI,copies of which will be furnished upon request. GENERAL NOTES, unless otherwise noted: 1. This design is based only upon the parameters shown and is for an individual building component.Applicability of design parameters and proper incorporation of component is the responsibility of the building designer. 2. Design assumes the top and bottom chords to be laterally braced at 2'o.c.and at 10'o.c.respectively unless braced throughout their length by continuous sheathing such as plywood sheathing(TC)and/or drywall (BC). 3. 2x Impact bridging or lateral bracing required where shown++, 4. Installation of truss is the responsibility of the respective contractor. 5. Design assumes trusses are to be used in a non-corrosive environment, and are for"dry condition"of use. 6. Design assumes full bearing at all supports shown. Shim or wedge if necessary. 7. Design assumes adequate drainage is provided. 8. Plates shall be located on both faces of truss,and placed so their center lines coincide with joint center lines. 9. Digits indicate size of plate In inches. 10. For basic connector plate design values see ESR-1311,ESR-1988(MiTek). O. a�g ! S' ` IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2.10=(-958) 2635 3.10=(-318) 336 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(-3001) 1231 10-11=(-697) 2186 10- 4=(-120) 564 WEBS: 2x4 KDDF STAND 3. 4=(-2717) 1165 11-12=(-716) 2136 4-11=(-785) 486 LOADING 4- 5=(-1912) 966 12- 8=(-960) 2567 11- 5=(-551) 1293 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5. 6=(-1912) 966 11- 6=(-785) 486 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-2717) 1165 6-12=(-120) 565 TOTAL LOAD = 42.0 PSF 7- 8=(-3001) 1231 12- 7=(-318) 336 OVERHANGS: 10.0" 10,0" 8- 9=( 0) 42 Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc BOTTOM CHORD CHECKED FOR A 20 PSF LIMITED STORAGE BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA M,M2OHS,M18HS,M16 = MiTek MT series LIVE LOAD AT LOCATION(S) SPECIFIED BY IBC 2012. LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) THE BOTTOM CHORD DEAD LOAD IS A MINIMUM OF 10 PSF. 0'- 0.0" -276/ 1775V -226/ 226H 5.50" 2.84 KDDF ( 625) 40'- 0.0" -276/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) 'COND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001' @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.178" @ 20'- 0.0" Allowed = 1.954" MAX TL CREEP DEFL = -0.330" @ 20'- 0.0" Allowed = 2.606" MAX LL DEFL = 0.001' @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111° MAX HORIZ. LL DEFL = 0.070" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.117" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES 20-00 20.00 NOT EXCEED 19%AT TIME OF MANUFACTURE. T '( T Design conforms to main windforce-resisting 7-00-05 6-05-136-05-13 6-05-13 6-05-13 7-00-05 system and components and cladding criteria. Wind: 140 mph, h=24.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 12 M-4x6 12 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 6.00 / 6.00 load duration factor=1.6, 4.0" Truss designed for wind loads 5 "' in the plane of the truss only. M-5x6(S) "rN M-5x6(S) /• 3.1 0.25" 0.25" ft li r> O 4 +a C. M-1°5x4 + A)410M-1.5x4 M M OIIIIO o �M-3x8 M-3x4 14.25" M-3x4 M-3x8V o M-5x8(S) y y J, ), y y 10-03-04 9-0!-12 9-08-12 10-03-04 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-6 NH - Al Scale: 0.1552 `�``�'t�>�v°F 6:5/ WARNINGS: GENERAL NOTES,unless otherwise noted: 3 -r -Y 1.Builder and erection contractor she Id be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual '4..,,:5' + p®il E -" Truss: Al and Warnings before construction..mmences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing mus be installed where shown+. incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to Ins re stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by fr is the responsibility of the erector. ddilional permanent bracing of 1wrr1^" continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). 1' '�! DATE: 7/11/2014 the overall structure is the responsi.ility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ ♦ t 4.No load should be applied to any.•mponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -Sy OREGON ' SEQ. : 5992791 fasteners are complete and at no 8 e should any loads greater than 5.Design assumes trusses are lobe used in a non-corrosive environment, 4. 'If \ As, design loads be applied to any co .onent, and are for"dry condition"of use. Jnn 1/)r 20 ..� TRANS I D: 403334 5.CompuTrus has no control over am assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if v1 , necessary. Mv- SF R.(L fabrication,handling,shipment and installation of components. 7.n Design s assumes adequate drainage is provided 8.This design is furnished subject to e limitations set forth by B.Plates shall be located on both faces of truss,and placed so their center IIID IIII VIII IIII I III IIII IIII III III TPI/VVI-CA in BCSI,copies of whic will be furnished upon request. git coincide with jointcenterinches.9.Digits indicate size of plate in inches. c MiT?k USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 11 IIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TO: 2x4 KDDF H1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2.12=(-1420) 2608 12- 3=( 0) 291 BC: 2x4 KDDF k1&BTR SPACED 24.0" O.C. 2- 3=(-3048) 1745 12-13=(-1422) 2605 3-13=(-547) 259 WEBS: 2x4 KDDF STAND 3- 4=(-2505) 1688 13-14=(-1231) 2235 13- 4=(-102) 534 LOADING 4- 5=( -597) 766 14.15=(-1231) 2235 13- 6=(-348) 150 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 4- 6=(-1683) 1035 15-16=(-1449) 2605 14- 6=( 0) 311 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 5- 7=( -481) 778 16-10=(-1447) 2608 6-15=(-348) 150 TOTAL LOAD = 42.0 PSF 6- 8=(-1683) 1035 8-15=(-102) 534 7- 8=( -597) 766 15- 9=(-547) 259 NOTE: 2x4 BRACING AT 24"OC UON. FOR t LL = 25 PSF Ground Snow (Pg) B- 9=(-2505) 1688 9.16=( 0) 291 ALL FLAT TOP CHORD AREAS NOT SHEATHED 9.10=(-3048) 1745 BOTTOM CHORD CHECKED FOR A 20 PSF LIMITED STORAGE 10-11=( 0) 42 LIVE LOAD AT LOCATION(S) SPECIFIED BY IBC 2012. OVERHANGS: 10.0" 10.0" THE BOTTOM CHORD DEAD LOAD IS A MINIMUM OF 10 PSF. BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA M-1.5x4 or equal at non-structural LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) vertical members (uon). 0'- 0.0" -460/ 1775V -197/ 197H 5.50" 2.84 KDDF ( 625) Unbalanced live loads have been 40'- 0.0" -460/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) considered for this design. ICOND,-2; Design checked for net(-5 psf) uplift at 24 "oc spacing.] Connector plate prefix designators: C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 M,M2OHS,M18HS,M16 = MiTek MT series MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10,0" Allowed = 0.111" MAX LL DEFL = 0.235" @ 22'- 7.4" Allowed = 1.954" MAX TL CREEP DEFL = -0.334" @ 20'- 0.0" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0,001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = -0.098" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.123" @ 39'- 6.5" 17-11-11 4-00-10 17-11-11 DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. 7-03-04 6-05-04 4-00 2-00-05 4-03-03 6-05-04 7-03-04 Design conforms to main windforce-resisting f < < -03 OB T f f T system and components and cladding criteria. 14-00 14-00 Wind: 140 mph, h=23.7ft, TCDL=4.2,BCDL=6.0, ASCE 7.10, 12 M-4x6 M-4x6 12 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, 6.00 I/ 5 M-3x8$ �7 Tr/- 6.00 inuss thedeed offor thewind trussoads O planeonly. M-4x6 - M-4x6 M-5x6(S) 0 0.25" 0.25" °' of t 9 M M OMMI FMO a 1 8 ... ,� . 8 1 W- 12 13 14 15 16 0 o TM-3x8 M-1.5x4 M-3x8 0.25" M-3x8 M-1.5x4 M-3x8 0 M-5x6(S) y y y y y y ,1 y 7-01-08 6-05-04 6-05-04 6-05-04 6-05-04 7-01-08 y y 0-10 40-00 0-10 Scale: 0.1547 PROF / JOB NAME : POLYGON PLAN 5-B NH - AH7 ` /GINS s ,-, WARNINGS: GENERAL NOTES,unless otherwise noted: ( , 1 � .�y� 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual t:r L,+1,r1i Truss: AH7 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown+. incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o,c.and at 10'o.c.respectively unless braced throughout their length by � r is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). �r+ +!! DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ : 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. 7OREGON '1,jr SEQ. : 5992792 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 1.- "4 1A.�. design loads be applied to any component. and are for"drycondition"of use. /nn � 253T" TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if i 14, necessary. 4/' /IRO' fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. �. 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII VIII VIII IIII VIII VIII IIII III III TPI/WFCA in BCSI,copies of which will be furnished upon request. lines coincide with joint center lines. -- 9.Digits indicate size of plate in inches. MiTek USA,Ino./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/3112 1 11 IIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 HOF 41&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2-12=(-1076) 2619 12- 3=( 0) 291 BC: 2x4 KOOF 41&BTR SPACED 24.0" O.C. 2- 3=(-3057) 1363 12.13=(-1078) 2616 3-13=(-534) 316 WEBS: 2x4 KDDF STAND 3- 4=(-2492) 1266 13-14=( -957) 2433 13- 4=(-267) 708 LOADING 4- 5=( 0) 0 14-15=( -957) 2433 13- 6=(-540) 250 TC LATERAL SUPPORT <= 12"0C. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 4. 6=(-2136) 1206 15.16=(-1130) 2616 14- 6=( 0) 311 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 8=(-2136) 1206 16-10=(-1128) 2619 6-15=(-539) 250 TOTAL LOAD = 42.0 PSF 7- 8=( 0) 0 8-15=(-268) 708 8. 9=(-2492) 1266 15- 9=(-534) 316 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 9-10=(-3057) 1363 9-16=( 0) 291 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10.11=( 0) 42 BOTTOM CHORD CHECKED FOR A 20 PSF LIMITED STORAGE LIVE LOAD AT LOCATION(S) SPECIFIED BY IBC 2012. OVERHANGS: 10.0" 10.0" THE BOTTOM CHORD DEAD LOAD IS A MINIMUM OF 10 PSF. BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) Connector plate prefix designators: 0'- 0.0" -319/ 1775V -156/ 156H 5.50" 2.84 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 40'- 0.0" -319/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series ]GOND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.] VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.209" @ 26'- 0.0" Allowed = 1.954" MAX TL CREEP DEFL = -0.358" @ 20'- 0.0" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = -0.083" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.127" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19% AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. 15-11-11 8-00-10 15-11-11 '( '1 Wind: 140 mph, h=23.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 7-03-04 6-05-04 2-03.0 4-00-05 4-00-05 -03-03 6-05-04 7-03-04 (All Heights), Enclosed, Cat.2, Exp.B, MWERS(Dir), T T 1' T T T T T T load duration factor=1.6, Truss designed for wind loads 14-00 14-00 in the plane of the truss only. 5 7 12 M-4x6 M-4x6 12 6.00 l ''' 4 M 6xe - \I6.00 M-5x8(5) M-5x8(5) v 0.25" 0.25" 0 m vo +. + to M M 0 O f_ v 1 e .« ». 1 tttr�t o 0 12 13 14 15 16 o TM-3x8 M-1.5x4 M-3x8 0.25" M-3x8 M-1.5x4 M-3x8 0 M-5x6(S) y y 1, /, /, y > , , 7-01-08 6-05-04 6-05-04 6-05-04 6-05-04 7-01-08 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-B NH - AH6 Sale: 0.1547 cOPRO 6>�.e� WARNINGS: GENERAL NOTES,unless otherwise noted: -* 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 't:.: l''' i® E r Truss: AH 6 and Warnings before construction sommences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing mus be installed where shown+, incorporation of component is the responsibility of the building designer. y 1010r ' 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at 1 DES. BY: BS is the responsibility of the erector.Additionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by P Y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). , . DATE: 7/11/2014 the overall structure is the respons bility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -Sy ,4��OREGON P,(f SEQ. : 5992793 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 7„ ", \� 4. design loads be applied to any component. and are for"dry condition"of use. / 2 �-. TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 0 �` 1 c5 necessary. 'Vl f� 1..y+ fabrication,handling,shipment anc installation of components. 7.Design assumes adequate drainage Is provided. RIR 11„- 6.This design is furnished subject to he limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 11111111111111111 TPI WTCA in BCSI,copies of whit 1 will be furnished upon request. git coincideitwith joint tecenter lines. 9.Digits indicate size of plate in inches. C* �f MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 11 IIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2-10=(-931) 2619 10- 3=( 0) 291 BC: 2x4 KDDF #1&BTR SPACED 24.0" 0.0. 2- 3=(-3057) 1165 10-11=(-933) 2616 3-11=(-534) 368 WEBS: 2x4 KDDF STAND 3- 4=(-2492) 1038 11-12=(-698) 2433 11. 4=(-241) 708 LOADING 4- 5=(-2136) 1015 12.13=(-698) 2433 11- 5=(-527) 203 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5- 6=(-2136) 1015 13-14=(-957) 2616 12- 5=( 0) 311 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-2492) 1038 14- 8=(-955) 2619 5.13=(-527) 203 TOTAL LOAD = 42.0 PSF 7- 8=(-3057) 1164 6-13=(-241) 708 8- 9=( 0) 42 13- 7=(-534) 368 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 7.14=( 0) 291 ALL FLAT TOP CHORD AREAS NOT SHEATHED BOTTOM CHORD CHECKED FOR A 20 PSF LIMITED STORAGE BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA LIVE LOAD AT LOCATION(S) SPECIFIED BY IBC 2012. LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 10.0" 10.0" THE BOTTOM CHORD DEAD LOAD IS A MINIMUM OF 10 PSF. 0'- 0.0' -247/ 1775V -155/ 155H 5.50" 2.84 KDDF ( 625) 40'- 0.0" -247/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) Connector plate prefix designators: C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series ICOND. 2: Design checked for net1-5 psf) uplift at 24 "oc spacing. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0,001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.179" @ 20'- 0.0" Allowed = 1.954" MAX TL CREEP DEFL = -0.358" @ 20'- 0.0" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0,001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = 0.076" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.127" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=22.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, 13-11-11 12-00-10 13-11-11 Truss designed for wind loads 1 T T T in the plane of the truss only. 7-03-04 6-08-07 6-00-05 6-00-05 6-08-07 7-03-04 12 12 6.00 1/ M-4x6 M-3x8 M-4x6 \I 6.00 5 • M-5x8(S) "" M-5x8(S) 0.25" 0.25" M M O O I.. �. .11114111111 .- 1 10 11 12 T 13 to _.s /o O 7M-3x8 M-1.5x4 M-3x8 6.25" M-3x8 M-1.5x4 M-3x8 O M-5x6(S) ), y y )' y y 1, 7-01-08 6-05-04 6-05-04 6-05-04 6-05-04 7-01-08 y y y y 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-B NH - AH5Sale: 0.1547 s ;` �p INE` C s/0 WARNINGS: GENERAL NOTES,unless otherwise noted: 445 /1 fj .? 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual CI; OP. E• f 4=" Truss: AH5 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at ' DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by a is the responsibility of the erector.Additional permanent bracing of continuous sheathingsuch as plywood sheathing(TC)C and/or d wall BC. '�"� Pcw 9R s ry ( ) , DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ �' ('� 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -Sy �EQ� f SEQ. : 5992794 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, �1x 1�� design loads be applied to any component, and are for"dry condition"of use. //� .•"i)„. 2� v.„S" TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if a '14, S fabrication,handling,shipment and installation of components. necessary. /� RR 1 L Qj 7.Designlaesassumesadequateon edth drainage is of truss, �,.. 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 1111111111111111 TPI/WfCA in BCSI,copies of which will be furnished upon request. git coincide with joint ate in ches 9.Digits indicate size of plate in inches. MITek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10,For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 111011VIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF H1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2.14=(-1134) 2587 3-14=(-135) 235 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(-3022) 1414 14-15=(-1211) 3183 14- 4=(-296) 899 WEBS: 2x4 KDDF STAND 3- 4=(-2812) 1314 15-16=(-1289) 3398 14- 6=(-976) 443 LOADING 4- 5=( 0) 0 16.17=(-1264) 3183 6.15=( -32) 304 TC LATERAL SUPPORT <= 12"0C. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 4- 6=(-2455) 1236 17-12=(-1187) 2587 15- 7=(-197) 130 BC LATERAL SUPPORT <= 12"0C. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-3285) 1508 7-16=(-197) 130 TOTAL LOAD = 42.0 PSF 7- 8=(-3285) 1508 16- 8=( -32) 304 8.10=(-2455) 1236 8.17=(-976) 443 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 9.10=( 0) 0 10-17=(-296) 899 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10-11=(-2812) 1314 17-11=(-135) 235 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11-12=(-3022) 1414 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 12-13=( 0) 42 OVERHANGS: 10.0" 10.0" BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP Connector plate prefix designators: AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) M,M2OHS,M18HS,M16 = MiTek MT series 0'- 0.0" -304/ 1775V -111/ 111H 5.50" 2.84 KDDF ( 625) 40'- 0.0" -304/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) ICOND. 2: Design checked for net(-5 paf) uplift at 24 "oc spacing.) VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001' @ 0'--10.0" Allowed = 0.083' MAX TL CREEP DEFL = -0.001' @ 0'--10.0" Allowed = 0.111° MAX LL DEFL = 0.273' @ 20'- 0.0" Allowed = 1.954' MAX TL CREEP DEFL = -0.495" @ 20'- 0.0" Allowed = 2.606° MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = -0.094" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.146" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. 11-11-11 16-00-10 11-11-11 Wind: 140 mph, h=22.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 5-01-08 4-07 2-10-09 5-01-12 5-01-12 2-10-09 4-07 5-01-08 load duration factor=l"6, T T -03-06 T T T 2-03-0 f T Truss designed for wind loads 10-00 10-00 in the plane of the truss only. 1' 1' T 1' /- 12 M-4x6 5 M-5x6(5) 9 M 4x6 12 6.00 V 4 M-331(4 7 0°25" M-83x4 D �I6.00 U o M-1"5x3 M-1"5x4 co 0 0 o 1 14 15 '1' T1� 17 -`13 o o 7M-3x8 M-3x8 0.25' 0.25' M-3x8 M-3x8 0 N-5x6(S) M-5x6(S) y 1, y y y y k 9-06-12 7-00-01 6-10-05 7-00-01 9-06-12 1-4 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-6 NH - AH4 Scale: 0.1547 5 C\ N;R 0� rQ WARNINGS: GENERAL NOTES,unless otherwise noted: 1 - . 1.Builder and erection contractor sho led be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 4t. C( ^',1 a 1! E 1"- Truss: AH4 and Warnings before construction mmences. building component.Applicability of design parameters and proper 2.204 compression web bracing mus be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to ins re stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector. ddaional permanent bracing of continuous sheathingsuch as plywood sheathing(TC)and/or d wall BC. ,,s,s,��",- DATE: Amor DATE: 7/11/2014 the overall structure is the respons'ility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ o' CC 4.No load should be applied to any mponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -�y ,g,�OREGON to SEQ. : 5992 795 fasteners are complete and at no tishould any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 4. "+i r,,lx j4 design loads be applied to any co onent. and are for"dry condition"of use. /�y �.• 2 ..�.,, TRANS I D: 403334 5.CompuTrus has no control over an assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if v 14, V, P necessary. /tip A I_v-' fabrication,handling,shipment and installation of components. 7. eassumes adequate drainage is provided. 6.This design is furnished subject to a limitations set forth by 8.plates shall be located on both faces of truss,and placed so their center III VIII III I I IIII III I IIID III IIII TPI/WfCA in BCSI,copies of which will be furnished upon request. git coincide with jointain che. 9.Digits size of plate in inches. MiTek USA,Inc./CompuTrus Spftware 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 11E111 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1. 2=( 0) 42 2-13=(-1012) 2587 3-13=(-136) 307 BC: 2x4 KDDF #1&BTR SPACED 24.0" 0.C. 2- 3=(-3022) 1237 13.14=) -974) 3183 13- 4=(-275) 899 WEBS: 2x4 KDDF STAND 3- 4=(-2812) 1094 14.15=(-1050) 3398 13- 5=(-976) 397 LOADING 4- 5=(-2455) 1044 15-16=(-1012) 3183 5-14=( -43) 304 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5. 6=(-3285) 1278 16-11=(-1044) 2587 14- 6=(-192) 143 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-3285) 1285 6-15=(-192) 133 TOTAL LOAD = 42.0 PSF 7- 9=(-2455) 1061 15- 7=( -35) 304 8- 9=( 0) 0 7-16=(-976) 389 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 9.10=(-2812) 1112 9.16=(-269) 899 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10-11=(-3022) 1247 16-10=(-136) 293 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11-12=( 0) 42 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. OVERHANGS: 10.0" 10.0" • BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA Connector plate prefix designators: AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 0'- 0.0" -241/ 1775V -111/ 111H 5.50" 2.84 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series 40'- 0.0" -245/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) ICOND. 2: Design checked for net(-5 psq__uplift at 24 "oc spacing.] VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = -0.246" @ 20'- 0.0" Allowed = 1.954" MAX TL CREEP DEFL = -0.495" @ 20'- 0.0" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = 0.088" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.146" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. 0-06-08 f-rWind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 9-11-11 19-09-05 10-03 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, X5_01-08 4-10 03 4-10-09 5-01-12 5-01-12 4-07-04 �� 4-07 5-01-08 Truss designed for wind loads in the plane of the truss only. 10-00 T < A- 6.001/ M-4x6 M-3x4 M 5 66(S) 0.25" M-3x4 s M 4x6 6.00 5E k ✓ M-1.5x4 o -1.5x4 o \/\/ yo co co o O o 1 13 a 2 o o M-3x8 M-3x8 b.25" 0.25' M-3x8 M-3x8 0 M-5x6(S) M-5x6(S) y y 9-06-12 7-00-01 6-10-05 7-00-01 9-06-12 y y 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-B NH - BH3 Scale: 0.,48, `x ° PR Ore Cs�s,,,99� WARNINGS: GENERAL NOTES,unless otherwise noted: ii1� 'T t" 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual t,;«� 2.411�i E .s- Truss: BH3 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. • 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY• BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,,.+' !,r DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ o Ct.. C 4. No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. 7OREGON ,(,i S E . . design loads be applied to any component. and are for"dry condition"of use. /nn '= 2, ., TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the e.Design assumes full bearing at all supports shown.Shim or wedge if s.+ /4, necessary. R R I cii�. fabrication,handling,shipment and installation of components. 7. necessary. gsassumes adequate drainage is provided. p E. 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII IIII VIII IIII 10111 IIII VIII III III TPIMlfCA in BCSI,copies of which will be furnished upon request. Digitsgit coincideictwith jointacenter lines. 8.linesindicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 1E11411 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0' IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR; LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2.13=(-1214) 2654 3.13=( -13) 272 2x6 KDDF #1&BTR T2 SPACED 24.0' O.C. 2- 3=(-3102) 1424 13.14=(-2120) 5340 13- 4=( -309) 975 BC: 2x6 KDDF #1&BTR 3- 4=(-3143) 1441 14-15=(-2516) 6278 13- 6=(-2713) 1079 WEBS: 2x4 KDDF STAND LOADING 4- 5=( 0) 0 15-16=(-2516) 6278 6-14=( -51) 491 LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 4- 6=(-2796) 1339 16-17=(-2432) 5740 14- 7=( -945) 423 TC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-5392) 2262 17-18=(-1207) 2684 15- 7=( 0) 258 BC LATERAL SUPPORT <= 12"0C. UON. TOTAL LOAD = 42.0 PSF 7- 8=(-5741) 2555 18.11=(-1204) 2686 7-16=( -596) 200 8- 9=(-2744) 1321 16- 8=( -11) 311 LL = 25 PSF Ground Snow (Pg) 9-10=(-2748) 1332 8.17=(-3796) 1672 NOTE: 2x4 BRACING AT 24"OC UON, FOR 10.11=(-3111) 1425 17- 9=( -913) 2127 ALL FLAT TOP CHORD AREAS NOT SHEATHED LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11.12=( 0) 42 17-10=( -354) 293 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 10.18=( 0) 180 OVERHANGS: 10.0" 10.0" BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) Connector plate prefix designators: 0'- 0.0" -289/ 1775V -118/ 118H 5.50" 2.84 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 40'- 0.0" -250/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series ICOND. 2: Design checked for net(-5 osf) uplift at 24 "oc spacings VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.536" @ 19'- 6.0" Allowed = 1.954" MAX TL CREEP DEFL = -0.975" @ 19'- 6.0" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = -0.097" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.148" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. 7-11-11 16-10-08 4-10-13 10-03 Wind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, f T T f (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 3-00-12 05-0 4-03-15 7-02-06 5-07-11 4-07-05 4-07-06 5-07-10 load duration factor=l.6, Truss designed for wind loads -05 1 fi in the plane of the truss only. 6-00 T T 12 12 M-4x6 12 6.00 1/ 6.00 1/ 4.0" �1 6.00 A- s44( 5 ur� o M-5x6 M-3x8 M- x8- M-5x16:- • 0 3x4 0 o M-1.5x4 o v �y4s 1111M8 2 � o ` 13 14-'r 15 l6 17 18 ..--.440,4 w o o M-3x8 M-4x12 0.25" M-1.5x4 0.25 M-5x12 M-1.5x4 M-3x8 0 =M-8x8(S) =M-8x8(S) y y y y y y ), y , , 5-04-12 7-02-06 6-10-14 5-04-03 4-10-13 4-09-02 5-05-14 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-B NH - BH2 Scale: 0.1481 (�� �0 PR Ore y WARNINGS: GENERAL NOTES,unless otherwise noted: J /(��r y.7 p1� 1.Builder and erection contractor shotkl be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 4t. \ `• i, S"� Truss: BH 2 and Warnings before construction Cpmmences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. c. 3.Additional temporary bracing to insyr'e stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS Pk 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ��- 4 DATE: 7/11/2014 the overall structure is the responsi lility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ y )e�� 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -� OREGON 4,,, SEQ. : 5992797 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, �, r�tu 1A� design loads be applied to any corn torrent. and are for"dry condition"of use. �' �.. 2,0 hl"' TRANS I D: 403334 5.CompuTrus has no control over anc assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 4 14, T necessary.ss R R l L fabrication,handling,shipment and Installation of components. 7.Design assumes adequate drainage is provided. 8.This design is furnished subject tot re imitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center IIII VIII IIII IIII VIII VIII IIII IIII TPI/vVECA in BCSI,copies of which)will be furnished upon request. git coincideiindicate with jointanr lines. 9.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXP(RES:12/31/2015 111111110 111 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS 40-00-00 GIRDER SUPPORTING 6-00-00 FROM 12-00-00 TO 19-00-00 IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR; LOAD DURATION INCREASE = 1.15 (Non-Rep) 1- 2=( 0) 42 2.12=( -958) 5580 3-12=( -120) 766 9-17=(0) 138 2x6 KDDF #18BTR T2 2- 3=( -6484) 1158 12-13=(-2356) 12824 12- 4=( -390) 2390 BC: 2x6 KDDF #1&BTR LOADING 3- 4=( -6788) 1218 13-14=(-2778) 15096 12- 5=(-7208) 1432 WEBS: 2x4 KDDF STAND LL = 25 PSF Ground Snow (Pg) 4- 5=( -6064) 1108 14.15=(-2778) 15096 5-13=( •330) 2050 TC UNIF LL( 50.0)+DL( 14.0)= 64.0 PLF 0'- 0.0' TO 40'- 0.0" V 5. 6=(-13056) 2488 15-16=(-2114) 12140 13- 6=(-2176) 410 IC LATERAL SUPPORT <= 12"OC. UON. BC UNIF LL( 0.0)+DL( 20.0)= 20.0 PLF 0'- 0.0" TO 12'- 0.0" V 6. 7=(-12140) 2210 16.17=( -754) 4772 14- 6=( -310) 1738 BC LATERAL SUPPORT <= 12"OC. UON. BC UNIF LL( 50.0)+DL( 54.0)=. 104.0 PLF 12'- 0.0" TO 19'- 0.0" V 7. 8=( -5222) 946 17.10=( -752) 4772 6-15=(-3278) 800 BC UNIF LL( 0.0)+DL( 20.0)= 20.0 PLF 19'- 0.0" TO 40'- 0.0" V B- 9=( -5218) 952 15- 7=( -258) 1390 9.10=( -5482) 926 7.16=(-8536) 1596 NOTE: 2x4 BRACING AT 24"OC UON, FOR ADDL: BC CONC LL+DL= 841.0 LBS @ 11'- 8.0" 10-11=( 0) 42 16- 8=( •750) 4348 ALL FLAT TOP CHORD AREAS NOT SHEATHED ADDL: BC CONC LL+DL= 1384.0 LBS @ 19'- 6.0" 16- 9=( -300) 328 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA OVERHANGS: 10.0" 10.0" REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) 0'- 0.0" -629/ 3446V -118/ 118H 5.50" 5.51 KDDF ( 625) Connector plate prefix designators: BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 40'• 0.0" -507/ 2917V 0/ OH 5.50" 4.67 KDDF ( 625) C,CN,CI8,CN18 (or no prefix) = CompuTrus, Inc AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. M,M2OHS,M18HS,M16 = MiTek MT series _,, ( 2 ) complete trusses required. 'COND. 2: Design checked for net(-5 psfl uplift at 24 "oc spacing.) Join together 2 ply with 16d Common nails staggered at VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 ** HANGER BY OTHERS TO APPLY CONC. 9" oc in 1 row(s) throughout 2x4 top chords, MAX LL DEFL = 0.000" @ 0'•-10.0' Allowed = 0.083" LOAD(S) EQUALLY TO ALL MEMBERS. 9' oc in 2 row(s) throughout 2x6 top chords, MAX TL CREEP DEFL = -0.000" @ 0'--10.0" Allowed = 0.111" 9" oc in 2 row(s) throughout 2x6 bottom chords, MAX LL DEFL = 0.401" @ 19'- 6.0" Allowed = 1.954" + Laterally brace to roof diaphragm. 9" oc in 1 row(s) throughout 2x4 webs. MAX TL CREEP DEFL = -1.255" @ 19'- 6.0" Allowed = 2.606" MAX LL DEFL = 0.000" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.000" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = -0.070" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.166" @ 39'• 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, 5-11-11 18-10-08 4-10-13 10-03 Truss designed for wind loads f f f f f in the plane of the truss only. 3-00-122-10-15 6-03-15 7-02-06 fi 5-07-11 4-07-05 4-07-06 5-07-10 12 12 12 6.00 / 6.00 I/ M-4x6 6.00 / 4.0" - 8 o M-5x6 M-3510 M-6x10 M-5x164M6 M-3x4 f 4 M-1.5x4 F o v ui o +_ co 1 0 0 0" o 1M-3x8 M-5x12 130.25" M-Med 3x6 0.25"15 M-5x12 M-117 5x4 1 o M18HS-7x14(S) ** M18HS-7x14(S) j 841# 1384# yy y ), y y y yy g;19 5-04-12 7-02-06 6-10-14 5-04-03 4-10-13 4-09-02 5-05-14 0 19 JOB NAME :° FOLYGON PLAN 5-B NH BH1 ao-oo Scale: 0.1480-10 1 � ‹e.. °0 .2 3 1h6�-�, qq� WARNINGS: GENERAL NOTES,unless otherwise noted: // A. ..t' BH1 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown end is for an individual 'f:'' 7.,."-�h i+ E c..• Truss: BH 1 and Warnings before construction commences, building component.Applicability of design parameters and proper G 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector.Additional permanent bracing of 2'o.c.and at 10'o.c,respectively unless braced throughout their length by ,r�� � I► continuous sheathing such as plywood in ere and/or drywall(BC). ..^'"!t- DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 10 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. OREGON SEQto �,• *�K As, TRANS I D: 403334 design loads be applied to any component, and are for"dry condition"of use. J 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at as supports shown.Shim or wedge if 0 ' 14, p. fabrication,handling,shipment and installation of components. necessary. 8.This design is furnished subject to the limitations set forth by7.Design assumes adequate drainage is provided. M R y N,• IIII II VIII IIII IIII(IIII(IIII III IIII III 1 8.Plates shall be located on both faces of truss,and placed so their center TPINYfCA In BCSI,copies of which will be furnished upon request. lines coincide with joint center lines. 9.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1888(MiTek) EXPIRES:12/31/2015 111111 IIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 I. 2=( 0) 42 2-15=(-1678) 3991 15- 3=(-353) 977 12.23=(0) 242 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(-4625) 1974 15.16=(-1549) 3653 3-16=(-721) 416 WEBS: 2x4 KDDF STAND 3- 4=(•3338) 1493 16.17=(-1176) 2930 16- 4=( -19) 289 LOADING 4. 5=(-2840) 1382 17-18=(-1056) 2757 4-17=(-519) 279 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5- 6=( 0) 0 19.20=( 0) 0 17- 5=(-400) 969 BC LATERAL SUPPORT <= 12°OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 5- 7=(-2481) 1295 18-20=(-1045) 2776 17- 7=(•640) 312 TOTAL LOAD = 42.0 PSF 7- 8=(-2785) 1416 20.21=(-1031) 2727 7.18=(-153) 492 8- 9=(-2797) 1389 21-22=(-1092) 2794 18- 8=(•182) 325 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 9-11=(-2288) 1229 22.23=(-1136) 2635 20- 8=(-665) 315 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10.11=( 0) 0 23-13=(-1134) 2638 8.21=( -75) 153 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11.12=(-2643) 1300 21- 9=( 0) 216 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 12-13=(-3077) 1361 9.22=(-710) 315 OVERHANGS: 10.0" 10.0" 13-14=( 0) 42 11-22=(-284) 807 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 22.12=(-385) 243 Connector plate prefix designators: AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA M,M2OHS,M18HS,M16 = MiTek MT series LOCATIONS REACTIONS REACTIONS SIZE SO.IN. (SPECIES) 0'- 0.0" -308/ 1775V -133/ 133H 5.50" 2.84 KDDF ( 625) 40'- 0.0" -309/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) ICOND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.] VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111° MAX LL DEFL = 0.260" @ 16'- 6.2" Allowed = 1.954" MAX TL CREEP DEFL = -0.466" @ 16'- 6.2" Allowed = 2.606" 0-01-05 MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" 13-11-11 12-00-10 13-11-11 MAX HORIZ. LL DEFL = -0.122" @ 39'- 6.5" 2-09 4-05-12 4 05 1205 04 6-01-04 21:03-op6-03-04 MAX HORIZ. TL DEFL = 0.188" @ 39'- 6.5" 2k-03.0 < 13-04-13 5-05-04 f DESIGN ASSUMES MOISTURE CONTENT DOES 12-00 12-00 NOT EXCEED 199;AT TIME OF MANUFACTURE. T T T Design conforms to main windforce-resisting 12 M-81X4 10 12 system and components and cladding criteria. A- 6.00 I/ M-4x65 M-31x8 M-31x4 1M-4x6 6.00 Wind: 140 mph, h=22.7ft, TCDL=4,2,BCDL=6.0, ASCE 7-10, _ t. (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, M 3x4 '� Truss designed for wind loads 0 4 + M-3x4 in the plane of the truss only. g- %M-4x43 M-3x8 ®� M-3x8 0 d0 M -� /-ui8� v 1 - 5 16 17 18 '�' ".��4 0 o o M-5x8 M-3x4 M-3x8 M- x6 20 0.2 � M 3x8 M-12 5x4 0 0 o M-3x4+ M-4x10 M 3x42.75 1 8' 12 M-5x6(S) 12 .1 .1 1' T-091 1 ). y y i -05-0 4-05-12 4-05-12 4-07-08 . 1,08-0, 6-03-06 6-01-04 5-05-04 6-01-08 0-1y0 2-05-08 11-11 ,42-00 23-07-08 0-10 y 14-04-08 25-07-08 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-B NH - AH5C Scale: 0.1332 �c,`t`t c4.53 N OFA WARNINGS: GENERAL NOTES,unless otherwise noted: Lt-. I/�® 1,,, -' 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual Ig 1... Truss: AH5C and Warnings before construction bommences. building component.Applicability of design parameters and proper " 2.204 compression web bracing mus be Installed where shown°. incorporation of component is the responsibility of the building designer. ° 3.Additional temporary bracing to in re stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY• BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector. dditional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). DATE: 7/11/2014 the overall structure is the responability of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ • ICt SEQ. : 5992799 4.No load should be applied to any domponent until after all bracing and 4.Installation of truss Is the responsibility of the respective contractor. T' OREGON tti fasteners are complete and at no tkne should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, y;. 'J rte` +f., design loads be applied to any component. and are for"dry condition"of use. / '�i . 2 '� TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the B.Design assumes full bearing at all supports shown.Shim or wedge if A 14, O'6fabrication,handling,shipment and installation of components. Decessary. I ry P P 7. necessary. ss assumes adequate drainage is provided. 'Vl RIO- 6. .This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII 11311101 IIIVIIIIIII MD VIII IIIIIII TPI WfCA in BCSI,copies of whish will be furnished upon request. git coincideitwith jointche. 9.Digitssiasize of tplate in inches.li . MiTek USA,IDC./ConrpuTfus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1888(MiTek) EXPIRES:12/31/2015 • 111111III This design prepared from computer input by PACIFIC LUMBER-BC • LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF N1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2-13=(-1439) 3991 13- 3=(-298) 977 9-20=(•264) 807 BC: 2x4 KDDF #1&BTR SPACED 24.0" 0,C. 2- 3=(-4625) 1712 13-14=(-1329) 3653 3.14=(•721) 386 20-10=(-387) 302 WEBS: 2x4 KDDF STAND 3- 4=(-3338) 1292 14.15=(-1028) 2930 14- 4=( -14) 289 10.21=( 0) 242 LOADING 4- 5=(-2840) 1155 15-16=( -815) 2757 4.15=(-519) 342 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5- 6=(-2481) 1098 17.18=( 0) 0 15- 5=(-337) 969 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-2785) 1177 16-18=( -812) 2776 15- 6=(-640) 244 TOTAL LOAD = 42.0 PSF 7- B=(-2797) 1159 18-19=( •802) 2727 6-16=(-161) 492 8- 9=(-2288) 1038 19-20=( •834) 2794 16- 7=(-104) 312 NOTE: 2x4 BRACING AT 24"0C UON. FOR LL = 25 PSF Ground Snow (Pg) 9-10=(-2643) 1076 20-21=( -972) 2635 18- 7=(-665) 253 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10.11=(-3077) 1172 21-11=( -970) 2638 7.19=( -55) 136 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11-12=( 0) 42 19- 8=( 0) 216 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 8-20=(-710) 275 OVERHANGS: 10.0" 10.0" BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA Connector plate prefix designators: AND BOTTOM CHORD LIVE LOADS ACT NON•CONCURRENTLY. LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 0'- 0.0" -242/ 1775V -133/ 133H 5.50' 2.84 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series 40'- 0.0" -242/ 1775V 0/ OH 5.50' 2.84 KDDF ( 625) 'GOND. 2: Design checked for net(-5 ssfl uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/160 MAX LL DEFL = D.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.232" @ 16'- 6.2' Allowed = 1.954" MAX TL CREEP DEFL = -0.466" @ 16'- 6.2' Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'• 10.0' Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10,0' Allowed = 0.111" MAX HORIZ. LL DEFL = 0.112" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.188" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES 11-11-11 16-00-10 11-11-11 NOT EXCEED 19%AT TIME OF MANUFACTURE. T T f f Design conforms to main windforce-resisting 2-09 4-05-12 4-08-15 2-01-05 6-01-04 5-04-13 5-08-07 6-03-04 system and components and cladding criteria. / 12 2-05-0 f f f 12 f Wind: 140 mph, h=22.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 6.00 V M-4x65 M- x4 M- x8 M- x4 9M-4x6 Q 6.00 load duration factor=1.6, Truss designed for wind loads :" in the plane of the truss only. M-3x4 4 M-3x4 v D o + tO %M-4x4 3 o cm o m-::!..400.10,°""°4(:::::::///1 � o O /T" e d o o o 1 _'! 13 14 15 i 6 8 1 20 21 ..��2 o O O M-5x8 M-3x4 M-3x8 17 0.25'' M-3x4+ M-5x6 1.89 M-4x10 (S) M-3x8 M-1.5x4 M-3x8 0 M-5x6 M-3x4+ . 2.7512 y J'12 y �2-09-12, ), ), y y )' 2-05-0 4-05-12 4-07-08 1;08 -0 6-03-06 6-01-04 5-05-04 6-01-08 > 0-1p 2-05-08 11-11 ,2-00 23-07-08 0,-10 J, y 14-04-08 25-07-08 y )- 0-10 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-B NH - AH4C Scale: 0.1499 �c'S�� Pv OFA WARNINGS: GENERAL NOTES,unless otherwise noted: "Y pt 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 4�Ls ♦Ap it,i E .c•- T r u s s: AH4C and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom braced to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). r 141111.0"DATE: 7/11/2014 the overall structure Is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ Ali" rtI- 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -Sy OREGON W SEQ. : 5992800 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, L- /f.� N� A. design loads be applied to any component. and are for"dry condition"of use. / )r r O. _1 TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if p� '1 , fabrication,handling,shipment and installation of components. necessary. '7�+. 7.Designassumes adequate ne hdrainage iso truss, <' R'L� 6.This design is furnished subject to the limitations set forth by 8,Plates shall be located on both feces of truss,and placed so their center 1111111111111111111111 TPI/WTCA in BCSI,copies of which will be furnished upon request. git coincide with joint tecenterin lines. 9.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/3112015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF 1/1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2.17=(-1427) 3488 17- 3=( -209) 663 BC: 2x4 KDDF 141&BTR SPACED 24.0" O.C. 2- 3=(-4158) 1779 17.18=(-1262) 3045 17- 4=( -186) 353 WEBS: 2x4 KDDF STAND 3- 4=(-3725) 1660 18-19=(-1439) 3656 4.18=( -191) 182 LOADING 4- 5=(-3215) 1467 20.21=( 0) 0 18- 5=( -402) 1134 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5- 6=( 0) 0 19.21=(-1501) 4109 18- 7=(-1196) 523 BC LATERAL SUPPORT <= 12"0C. UON. DL ON BOTTOM CHORD = 10.0 PSF 5- 7=(-2846) 1359 21.22=(-1559) 4171 7.19=( -269) 907 TOTAL LOAD = 42.0 PSF 7. 8=(-4286) 1837 22-23=(-1449) 3686 8.19=( -85) 46 8- 9=(-4282) 1836 23.15=(-1108) 2440 19- 9=( -253) 596 NOTE: 2x4 BRACING AT 24"OC UON. FOR LL = 25 PSF Ground Snow (Pg) 9-10=(-4019) 1727 21- 9=( -822) 404 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10-11=(-3994) 1670 21-10=( -192) 106 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11.13=(-2515) 1227 10.22=( -310) 220 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 12-13=( 0) 0 22-11=( -80) 536 OVERHANGS: 10.0" 10.0" 13.14=(-2863) 1308 11.23=(-1427) 576 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP • 14-15=(-2908) 1337 13.23=( -284) 918 Connector plate prefix designators: AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. 15-16=( 0) 42 23.14=( -2) 204 C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA JT 15: Heel to plate corner = 2.00" LOCATIONS REACTIONS REACTIONS SIZE SG.IN. (SPECIES) 0'- 0.0" -300/ 1775V -89/ 89H 5.50" 2.84 KDDF ( 625) 40'- 0.0" -301/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) ICOND. 2: Design checked for net(-5 sat) uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" 9-11-11 20-00-10 9-11-11 MAX TL CREEP DEFL = -0.001' @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.381" @ 21'- 6.8" Allowed = 1.954" MAX TL CREEP DEFL = -0.712' @ 21'- 6.8" Allowed = 2.606" 2-08-08 2-03-03 3-0 -04 5-07-13 3-01-02 3-10 MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" T TT T ' T '[ MAXf TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" 2-01-12 2-10-0:11--T)-18-05 2-01-12 5-04-05 2-03-0 3-10-08 T f ' f 1L'( '1' ' f '1 T T f '1 MAX HORIZ. LL DEFL = -0.131" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.207" @ 39'- 6.5" T 8-00 f T 8-00 DESIGN ASSUMES MOISTURE CONTENT DOES 12 M-5x6(S) 12 NOT EXCEED 19%AT TIME OF MANUFACTURE. 6.00" M-3x4 M-3x4 12 6.00 Design conforms to main windforce-resisting M-5x6 -165x4 O,aS° =M-14.1x4 M-4x6 system and components and cladding criteria. 5 7 9 1 3 Wind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, M-3x4 y=!! AM`+` (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), o a \ M-1.5x4 Load duration factor=l.6, ,I ® 1 4 Truss designed for wind loads v M-3x8 5x43iglp ^ in the plane of the truss only. O N O J .� � O • ,It�� st 1 •1 � 18 1- """ ap 6 'n M-5x10 0 o M-3x8 M-6x1021 0.2o'� M 3x8 M-3x8~1 0 M-3x4+ M-3x4+ M-4x12 a 2.75 1.89 v M-5x8(S) 12 12 2-00 5-06-12 6-04-04 1-00-12 9-03-04 8-02-04 7-06-12 J-)----4 )4 0-10 2-00 11-11 2-00 24-01 y 10 13-11 26-01 y y ky 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-B NH - AH3Spate: 0.1400 )1 � (PS WARNINGS: GENERAL NOTES,unless otherwise noted: ZGr /// / "�`.�,r 1.Builder and erection contractor sh. Id be advised of all General Notes 1.This design Is based only upon the parameters shown and is for an individual {.• a Uh `.- Truss: AH3 and Warnings before construction •mmences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing mus be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to ins re stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES• BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector. dditional permanent bracing of continuous sheathingsuch as plywood sheathing(TC)and/or d well BC. !! �� DATE: 7/11/2014 the overall structure is the respons.ility of the building designer. 3.2x Impact bridging r lateral bracing required where hown 0* ( ) `" 4.No load should be applied to any mponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. - OREGON l,4 SEQ. : 5992801 fasteners are complete and at no ti should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 1x`y�� design loads be applied to any co ••rent. and are for"dry condition"of use. / '1)•' r�(3.\ce'(�r TRANS I D: 403334 5.CompuTrus has no control over an assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if 14, T' necessary. FI R I L-\ fabrication,handling,shipment an.installation of components. 7.n Design assumes adequate drainage is provided. 8.This design is furnished subject to e limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 1111111111111111111111 TPINVECA in BCSI,copies of whic will be furnished upon request. git coincideictwith jointanr lines. 9.Digits indicate size of plate in inches. e MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-Z 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXP(RES:12/311201.5 11 IIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 40'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 IC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2-15=(-1267) 3488 15. 3=( -161) 663 21-12=(0) 204 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(-4158) 1554 15.16=(-1096) 3045 15- 4=( -173) 353 WEBS: 2x4 KDDF STAND 3. 4=(-3725) 1463 16-17=(-1145) 3656 4.16=( -192) 258 LOADING 4- 5=(-3215) 1216 18.19=) 0) 0 16- 5=( -358) 1134 IC LATERAL SUPPORT <= 12"OC, UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5- 6=(-2846) 1133 17-19=(-1245) 4109 16- 6=(-1196) 451 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF 6- 7=(-4286) 1560 19.20=(-1292) 4171 6-17=( -275) 907 TOTAL LOAD = 42.0 PSF 7- 8=(-4282) 1558 20.21=(-1162) 3686 7-17=( -85) 56 8- 9=(-4019) 1481 21.13=( -978) 2440 17- 8=( -184) 596 NOTE: 2x4 BRACING AT 24"0C UON. FOR LL = 25 PSF Ground Snow (Pg) 9-10=(-3994) 1421 19- 8=( -822) 337 ALL FLAT TOP CHORD AREAS NOT SHEATHED 10.11=(-2515) 1026 19- 9=( -182) 104 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 11-12=(-2863) 1085 9-20=( -310) 224 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 12.13=(-2908) 1176 20-10=) -84) 536 OVERHANGS: 10.0" 10.0" 13.14=) 0) 42 10.21=(-1427) 518 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 11-21=( -266) 918 Connector plate prefix designators: AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA M,M2OHS,M18HS,M16 = MiTek MT series LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) 0'. 0.0" -235/ 1775V -89/ 89H 5.50" 2.84 KDDF ( 625) JT 13: Heel to plate corner = 2.00" 40'- 0.0" -236/ 1775V 0/ OH 5.50" 2.84 KDDF ( 625) 'COND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/18D MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = -0.354" @ 21'- 6.8" Allowed = 1.954" MAX TL CREEP DEFL = -0.712" @ 21'- 6.8" Allowed = 2.606" MAX LL DEFL = 0.001" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 40'- 10.0" Allowed = 0.111" MAX HORIZ. LL DEFL = 0.124" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.207" @ 39'- 6,5" DESIGN ASSUMES MOISTURE CONTENT DOES 7-11-11 24-00-10 7-11-11 NOT EXCEED 19%AT TIME OF MANUFACTURE. 2-01-1 3-01-07 3-01-04 5-07-13 5-04-05 5-01-02 4-01-03 3-10-08 Design conforms to main d windforce-resistingdding 1 1 system and components and cladding criteria. 2-08-08� 12-08-051 L-01-1"L 12 Wind: 140 mph, h=21.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 12 M-3x4 M-5x6(5) (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 6.00 M-5x6 M-4x6 6.00 load duration factor=1.6, 5 M- x4 M-1)5x4 B (1 ,25" =M-10x4 1 Truss designed for wind loads M-3x4 9€ ,� ao in the plane of the truss only. 4 M-1.5x4 o M-1"5x4 + 2 .1. 0.1 o M 3X8 �� mm o /-p o vo i .. - 15 M-5x10 16 17r " RE .� 4 yo 0 o M-3x4+ M-3x8 M-6x10 19 0.25'° 21 ''1 M-3x4+ M-3x8 M-3x8 0 1.89 M-4x12 M-5x8(S) a 2.75 12 y y2-00, 5-06-12 6-04-04 1-p0-12, 9-03-04 8-02-04 7-06-12 6 y 0-1y0 2-00 11-11 ,2-00 24-01 Oy 10 13-11 26-01 yy yy 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-B NH - AH2 Scale: 0.1550 ` ,ti opt. WARNINGS: GENERAL NOTES,unless otherwise noted: y56 /f+ ( 'T -!2 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual r. tG, LJ.,J„tr'ii" Truss: AH 2 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown+- incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,,.+"+"tax. 4,4111.1.P DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ A.`(It. SEQ 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. 17 4_OREGON �1, S E Q �„ '37' TRANS I D: 4033341 design loads be applied to any component. and are for"dry condition"of use. / 4}r 20 5.CompuTrus has no control over and assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if 0 14, S.,.T fabrication,handling,shipment and installation of components. necessary. j 7.Design assumes adequate drainage Is provided. -r-f?R(L� 6.This design is furnished subject to the imitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center III VIII I III I IIII IIII II IIII III TPIANTCA in BCSI,copies of which will be furnished upon request lines coincide with joint center lines. 9.Digits indicate size of plate in inches. MiTek USA,InC./CompuTfus Software 7.6.6(1 L)-Z 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/201.5 1111110111 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS 40.00-00 HIP SETBACK 6-00-00 FROM END WALL IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR; LOAD DURATION INCREASE = 1.15 (Non-Rep) 1- 2=( 0) 42 2-14=(-3052) 8834 14- 3=( -652) 2126 10.20=(-562) 1884 2x6 KDDF #1&BTR T2, T3 2- 3=(-10036) 3504 14.15=(-2800) 8048 3.15=( -842) 308 20-11=(-288) 726 BC: 2x6 KDDF #1&BTR LOADING 3- 4=( -7926) 2942 15.16=(-4330) 11250 15- 4=( -860) 2530 WEBS: 2x4 KDDF STAND LL = 25 PSF Ground Snow (Pg) 4- 5=( -7068) 2654 16-17=(-5512) 14076 15- 5=(-4662) 1980 TC UNIF LL( 50.0)+DL( 14.0)= 64.0 PLF 0'- 0.0" TO 6'- 0.0" V 5- 6=(-11444) 4480 17.18=(-5048) 12796 5-16=( -398) 1412 TC LATERAL SUPPORT <= 12"0C. UON. TC UNIF LL( 100.0)+DL( 28.0)= 128.0 PLF 6'- 0.0" TO 34'- 0.0" V 6- 7=(-14240) 5666 18-19=(-5020) 12570 16- 6=(-2954) 1272 BC LATERAL SUPPORT <= 12"OC. UON. TC UNIF LL( 50.0)+OL( 14.0)= 64.0 PLF 34'- 0.0" TO 40'- 0.0" V 7- 8=(-12464) 5012 19.20=(-4110) 10414 6-17=( -414) 1192 BC UNIF LL( 0.0)+DL( 40.0)= 40.0 PLF 0'- 0.0" TO 40'- 0.0" V 8- 9=(-11704) 4500 20.12=(-1888) 5362 17- 7=( -946) 2576 9-10=( -5842) 2162 18- 7=(-2594) 1180 NOTE: 2x4 BRACING AT 24"OC UON. FOR TO CONC LL( 250.0)+DL( 70.0)= 320.0 LBS @ 6'- 0.0" 10.11=( -6516) 2378 18- 8=( -114) 122 ALL FLAT TOP CHORD AREAS NOT SHEATHED TG CONC LL( 250.0)+DL( 70.0)= 320.0 LBS @ 34'- 0.0" 11-12=( -6230) 2234 8.19=(-1142) 820 12.13=( 0) 42 19- 9=( -392) 1702 LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 9.20=(-4962) 2222 OVERHANGS: 10.0" 10.0" REGUIREMPNTS OF IBC 2012 AND IRC 2012 NOT BEING MET. BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA Connector plate prefix designators: BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. 0'- 0.0" -1152/ 3391V -65/ 65H 5.50" 5.43 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series 40'- 0.0" -1152/ 3391V 0/ OH 5.50" 5.43 KDDF ( 625) ( ) complete trusses required. Jn together 2 ply with 16d Common nails staggered at oc in 1 row(s) throughout 2x4 top chords, 'COND. 2: Design checked for net(-5 osf) uplift at 24 "oc spacing.' 9" oc in 2 row(s) throughout 2x6 top chords, VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 90 oc in 2 row(s) throughout 2x6 bottom chords, MAX LL DEFL = 0.000" @ 0'--10.0" Allowed = 0.083" !"' oc in 1 row(s) throughout 2x4 webs. MAX TL CREEP DEFL = -0.000" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.565" @ 16'- 4.5" Allowed = 1.954" + Laterally brace to roof diaphragm. MAX TL CREEP DEFL = -1.074" @ 16'- 4.5" Allowed = 2.606" MAX LL DEFL = 0.000" @ 40'- 10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.000" @ 40'- 10.0" Allowed = 0.111° MAX HORIZ. LL DEFL = -0.137" @ 39'- 6.5" MAX HORIZ. TL DEFL = 0.220" @ 39'- 6.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19% AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=20.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 5-11-11 28-00-10 5-11-11 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=l.6, T T Truss designed for wind loads 2-09 3-02-11 3-08-05 4-05 2-03-08 6-02-11 5-11-03 5-06 2-10-15 3-00-12 in the plane of the truss only. 320# T T T T T 320# T T 12 12 6.00 I/ M-4x10 M-3x8� M-7x8(S)M 6x4 M 4x4 0.625" M-9x10 M-5x6 "---..1 6. 00 %M 4Xt., r * M-1.5x4 + C, o o M-3x10 `i o /-o 4r 1 r �4 15 16 17� 9 20 '--7! %3o 18 .�9 M-6x8 M-4x10 =M-4x4 =M-10x10 0.25}' M-4x10 M-3x8 0 0 o M-3x4+ M18HS-7x14 M-3x4+ -- 2.75 M 3x4+ =M-8x8(S) M-3x4+ 12 2.75 0 y 2-11-04/ y 12 , y y y y > y 2-05-06 4-06-12 4-05 ,2-00, 9-02-04 9-00-08 5-04-12 Oy 1p 2-05-08 11-11 2-00 23-07-08 9,12113 0-10 40-00 0-10 JOB NAME : POLYGON PLAN 5-B NH - 'AHIScale: 0.1548 `c, ,4t))),,PNOr 6T, �� WARNINGS: GENERAL NOTES,unless otherwise noted: C(fes. ; - * 1.Builder and erection contractor shopld be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual I,'2»- w f"' Truss: AH 1 and Warnings before construction ommences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. Y 3.Additional temporary bracing to ins re stability during construction 2.Design assumes the top and bottom chords to be laterally braced at A 2'o.c,and at 10'o.c,respectively unless braced throughout their length by r, DES. BY: BS Is the responsibility of the erector. ddaional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). a , DATE: 7/11/2014 the overall structure is the respons bility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 4.No load should be applied to any cilmponent until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -y OREGON SEQ. : 5992803 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, L. 4tt7' /r TRANS I D: 403334 design loads be applied to any component. and are for"dry condition"of use. / '9}+ +'1Q 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 1 �<�s. fabrication,handling,shipment and installation of components. necessary. U P P 7.Designlaesassumesadequateon edthinace isprovided.truss,a. RIO- 6. This design is furnished subject to Fe limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center IIIIII VIII I III I VIII VIII VIII I II IIII TPINVECA in BCSI,copies of whit 1 will be furnished upon request. git coincideictwith jointcenter inches.0.Digitssindsize of tplate in ilines. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 9'- 6.0" ICOND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.' TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 BC: 2x4 KDDF H1&BTR SPACED 24.0" O.C. DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. IC LATERAL SUPPORT <= 12"OC. UON. LOADING Design conforms to main windforce-resisting BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF system and components and cladding criteria. Connector plateprefix designators: DL ON BOTTOM CHORD = 10.0 PSF g TOTAL LOAD = 42.0 PSF C,CN,CI8,CN18 (or no prefix) = CompuTrus, Inc Wind: 140 mph, h=s),4Enc Enclosed, LExp. ASCE 7-10, M,M2OHS,M18HS,M16 = MiTek MT series LL = 25 PSF Ground Snow (Pg) (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1,6, LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL Truss designed for wind loads REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET, in the plane of the truss only. BOTTOM CHORD CHECKED FOR tOPSF LIVE LOAD. TOP Gable end truss on continuous bearing wall UON. AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. M-1x2 or equal typical at stud verticals. Refer to CompuTrus gable end detail for 4-09 4-09 complete specifications. 12 12 6.00 I/ \6.00 IIM-4x4 /- 3 co 0 CM co 2 4 O/ co —/O 0 5 . o� 1 I/�/////// //////////�/// ///�/////lam////tel////II//Y///// // I a M-3x4 M-3x4 1, y y y 0-10 9-06 0-10 JOB NAME : POLYGON PLAN 5-B NH - Cl .ckScale: 0.6187 �0 P °pp s99t WARNINGS: GENERAL NOTES,unless otherwise noted: //// .�` Cl1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual t,' _r{241 1 E �f.�^ Truss: C and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+. incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced et DES. BY: BS is the responsibility of the erector.Additional permanent bracing of 2'o.c.and at 10'o.c.respectively unless braced throughout their length by ��r► continuous sheathing such as plywood in ere and/or drywall(BC). r- DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ *" 4.No load should be applied to any component until after all bracing and 4, Installation of truss is the responsibility of the respective contractor. "y OREGON A. TRANS I D: 403334 4/ SEQ. : 5992804 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, b' Ce) design loads be applied to any component. and are for"dry condition"of use. 6 //�� ,</y.5.CompuTrus has no control over and assumes no responsibility for the .Design assumes full bearing at all supports s shown.Shim or wedge if 1 , �(� fabrication,handling,shipment and installation of components. necessary. C�c� 7.Design assumes adequate drainage is provided M r-t n 1 0,- 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII I I VIII IIII IIII IIII VIII III III TPIMlfCA in BCSI,copies of which will be furnished upon request. git coincideialwithizjointcenterche. 9.Digits indicate size of plate in inches. e MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES.12/31/2015 111111111 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 20'- 6.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2- 7=(-252) 1166 3- 7=(-283) 205 BC: 2x4 KDDF #1&BTR SPACED 24.0" 0.0. 2- 3=(-1392) 328 7- B=( -95) 772 7- 4=(-101) 446 WEBS: 2x4 KDDF STAND 3- 4=(-1216) 326 8- 6=(-246) 1169 4- 8=(-101) 450 LOADING 4- 5=(-1218) 339 8- 5=(-287) 206 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5. 6=(-1395) 339 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF TOTAL LOAD = 42.0 PSF OVERHANGS: 10.0" 0.0" BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA LL = 25 PSF Ground Snow (Pg) LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) ** For hanger specs. - See approved plans 0'- 0.0" -143/ 961V -92/ 98H 5.50" 1.54 KDDF ( 625) Connectorplate prefix designators: LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 20'- 6.0' -107/ 860V 0/ OH 5.50" 1.38 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT seriesBOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP !COND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing,! AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0,001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = -0.037" @ 13'- 5.8" Allowed = 0.979' MAX TL CREEP DEFL = -0.075' @ 13'- 5.8" Allowed = 1.306" MAX HORIZ. LL DEFL = 0.016" @ 20'- 0.5" MAX HORIZ. TL DEFL = 0.026" @ 20'- 0.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19t AT TIME OF MANUFACTURE. 10-03 10-03 Design conforms to main windforce-resisting 5-03-14 4-11-02 4-11-02 5-03-14 system and components and cladding criteria. 1 < '( < T Wind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 12 12 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 6.00 M-4x6 6.00 lTrad russduration designedffor owind 6loads f- 4 4.0" in the plane of the truss only. i!)III M4s- o , >1.5X415i 7 8 ..g o o M-3x4 0.25" M-3x4 M-3x4 O M 5x6(S) y : y y 7-00-03 6-05-11 7-00-03 > y 0-10 20-06 JOB NAME : POLYGON PLAN 5-B NH - D2 cc O PROFF s;Q Scale: 0.2933 WARNINGS: GENERAL NOTES,unless otherwise noted: tl,f /// , /7 1.Builder and erection contractor should be advised of all General Notes 1.This design Is based only upon the parameters shown and is for an Individual s G�Gh FF" Truss: D2 and Warnings before construction Commences. building component.Applicability of design parameters and proper Ipp- 2.2x4 compression web bracing mu4 be installed where shown+. incorporation of component Is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector.Additionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by P Y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,,,//1111ir" DATE• 7/11/2014 the overall structure is the responliibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ �'" SEQ. : 5992805 4. No load should be applied to any domponent until aver all bracing and 4. Installation of truss is the responsibility of the respective contractor. ,,qq.�OREGON 4c"r fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a noncorrosive environment, �4+- •y �\ h„ design loads be applied to any component. and are for"dry condition"of use. �' TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if -It- 14 necessary. Fl V fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. A=+1 Ri k,.`^- 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center MINI VIII IIII VIII VIII ling IIII TPI VYTCA in BCSI,copies of whir h will be furnished upon request. git coincide with joint center che. Software 9. Digitssdsize of tplate in inches.. MiTek USA,IDC./Compulrua software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 111111III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 21'- 4.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR; LOAD DURATION INCREASE = 1.15 1.3=(-522) 168 1-5=(-127) 422 3.5=(0) 214 2x6 KDDF N1&BTR T1 SPACED 24.0" O.C. 2.3=( 0) 0 5-4=(-123) 424 BC: 2x4 KDDF#1&BTR 3-4=(-539) 187 WEBS: 2x4 KDDF STAND LOADING LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF TC LATERAL SUPPORT <= 12"0C. UON. DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA BC LATERAL SUPPORT <= 12"OC. UON. TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) 0'- 0.0" -382/ 424V -32/ 34H 137.50" 0.68 KDDF ( 625) LL = 25 PSF Ground Snow (Pg) 20'- 6.0" -68/ 417V 0/ OH 5.50" 0.67 KDDF ( 625) LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL ICOND. 2: Design checked for net(-5 psfl uplift at 24 Hoc spacin 1 REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. g' M-1.5x4 ore equal at non-structural VERTICAL DEFLECTION LIMITS: LL=L1240, TL=L/160 q BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.000" @ 11'- 0.0" Allowed = 0.083" vertical members (uon). AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = 0.000" @ 11'- 0,0" Allowed = 0.111" Connector plate prefix designators: MAX TL CREEP DEFL = -0.012" @ 15'- 9.0" Allowed = 0.572" C,CN,CI8,CN18 (or no prefix) = Com uTrus, Inc MAX TC PANEL LL DEFL = 0.007" @ 13'- 2,0" Allowed = 0,291" M,M2OHS,M18HS,M16 = MiTek MT series Refer to CompuTrus standard gable end detail for complete MAX HORIZ. LL DEFL = 0.003" @ 20'- 0.5" specifications. MAX HORIZ. TL DEFL = 0.005" @ 20'- 0.5" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19% AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. 10-03 10-03 Wind: 140 mph, h=20.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, T T T (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 14-03 1-06 4-09 load duration factor=l.6, Truss designed for wind loads in the plane of the truss only. 12 -7--M-4x4+ 12 /- 6,0o I/ X16.00 a. M-4x6- 14, 3 0444.0. s-, to + M-3x4+ -- M1 co O O f- OA -- V O O O M-3x6 y M-1.5x4 M-3x4 y M-3x6(S) y 11-05-08 y y 15-09 4-09 y ) y 0-10 20-06 JOB NAME : POLYGON PLAN 5-6 NH - D1 Scale: 0.2992 `��` 0� ,°f 0 WARNINGS: GENERAL NOTES,unless otherwise noted. f1Jr /v 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual tx� �G�, `;✓" Truss: D1 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector.Additional 2'o.c.and at 10'o.c.respectively unless braced throughout their length by rrlr p y permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). rix - DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ . >�� 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -� OREGON `ti SEQ. : 5992806 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, y+ !. Tj / design loads be applied to any component. and are for"dry condition"of use. / 1,.. V t�_.1 TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the e.Design assumes full bearing at all supports shown.Shim or wedge if 14 s fabrication,handling,shipment and installation of components. necessary. iii �s. 7.Designlaesassumes adequate hdrainage iso truss, ,�/r;; RI 1,. 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both feces of truss,and placed so their center VIII VIII VIII IIII I II IIII VIII III IIII TPI WTCA in BCSI,copies of which will be furnished upon request. git coincideictwith jointcenter lines. 9. Digits indicate size of plate in inches. Cn MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-Z 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES: 2/31.1201.5 11 1111M11 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 11'- 8.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF N1&BTR LOAD DURATION INCREASE = 1.15 1.2=( 0) 42 2-5=(-40) 429 5.3=(0) 265 BC: 2x4 KDDF k1&BTR SPACED 24.0" O.C. 2.3=(-574) 113 5-4=(-40) 429 WEBS: 2x4 KDDF STAND 3.4=(-573) 124 LOADING TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BAG REQUIRED BRG AREA TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ•IN. (SPECIES) OVERHANGS: 10,0" 0.0" 0'- 0.0" -96/ 594V -50/ 57H 5.50" 0.95 KDDF ( 625) LL = 25 PSF Ground Snow (Pg) 11'- 8.0" -58/ 489V 0/ OH 5.50" 0.78 KDDF ( 625) ** For hanger specs. - See approved plans LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL Connector plate prefix designators: 'COND. 2: Design checked for net(-5 osf) uplift at 24 "oc spacing.' C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. M,M2OHS,M18HS,M16 = MiTek MT series VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX TC PANEL LL DEFL = 0.026" @ 8'- 6.3" Allowed = 0.383" MAX TC PANEL TL DEFL = 0.075" @ 8'- 6.3" Allowed = 0.575" MAX HORIZ. LL DEFL = 0.003" @ 11'- 2.5" 5-10 5-10 MAX HORIZ. TL DEFL = 0.006" @ 11'- 2.5" -r T T 12 12 DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. 6.00I/ IIM-4x4 \I6.00 Design conforms to main windforce-resisting 4.0" system and components and cladding criteria. 3 �I Wind: 140 mph, h=20.6ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, Truss designed for wind loads in the plane of the truss only. 1.1 co 0 cO O CO co O/ II -/O V -- RR V A- oA_ 1 ._- 5 4 ** -/O 0 M-3x4 M-1.5x4 M-3x4 y 1, y 5-10 5-10 1, 1, y 0-10 11-08 JOB NAME : POLYGON PLAN 5-B NH - E2 Scale: 0.4999 �c,`t 0)iPN 0 �'�g� WARNINGS: GENERAL NOTES,unless otherwise noted: ' "fr1 1.Builder and erection contractor she pld be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual Gr� _ t U�";e E it Truss: E2 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. c 3.Additional temporary bracing to inssre stability during construction 2.Design assumes the top and bottom chords to be laterally braced atAle , DES. BY• BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by141111111.' no. • is the responsibility of the erector.Additional permanent bracing of continuous sheathingsuch asplywood sheathing(TC)C and/or d all BC. aAtt!, g(T ) ryw ( ) .:+'�`;,, DATE: 7/11/2014 the overall structure Is the responsiMity of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ - l�� 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -7OREGON 4/ SEQ. : 5992807 fasteners are complete and at no fine should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, y /Gj S A. design loads be applied to any component. and are for"dry condition"of use. / },- 14, r 2P '.. TRANS I D: 403334 5.CompuTrus has no control over ant assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if �b 14, necessary. 'VI R R 1 L fabrication,handling,shipment and installation of components. 7. necessary. s assumes adequate drainage Is provided. P �... 6.This design is furnished subject to tie limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 111111111111111111111 TPI/WfCA in BCSI,copies of which will be furnished upon request. git coincide with jointcenter lines. 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus S ftWare 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1985(MiTek) EXPI RES:12/31)2015 11111111111 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 11'- 8.0" ICOND. 2: Design checked for net(-5 osf) uplift at 24 "oc soacing.l IC: 2x4 KDDF k1&BTR LOAD DURATION INCREASE = 1.15 DESIGN ASSUMES MOISTURE CONTENT DOES BC: 2x4 KDDF b1&BTR SPACED 24.0" O.C. NOT EXCEED 19%AT TIME OF MANUFACTURE. TC LATERAL SUPPORT <= 12"OC. UON. LOADING Design conforms to main windforce-resisting BC LATERAL SUPPORT <= 12"OC. UON, LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF system and components and cladding criteria. DL ON BOTTOM CHORD = 10.0 PSF Connector plate prefix designators: TOTAL LOAD = 42.0 PSF Wind: 140 mph, h=20.6ft TCDL=4.2,BCDL=6.0, ASCE 7-10, C,CN,CI8,CN18 (or no prefix) = CompuTrus, Inc p M,M2OHS,M18HS,M16 = MiTek MT series LL = 25 PSF Ground Snow (Pg) (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=l.6, LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL Truss designed for wind loads REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. in the plane of the truss only. BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP Gable end truss on continuous bearing wall UON. M-1x2 or equal typical at stud verticals. AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. Refer to CompuTrus gable end detail for 5-10 5-10 complete specifications. T T T 12 12 6.00 I/ I I M-4x4 6.00 3 r) 0 c') 0 r) r) 2 4 r) O,x_ —7o .3 — — — — e} a/— 1 //////////////////////////////////////////////////////////////////////////////////////////// 5 C3 0 0 M-3x4 M-3x4 J, y ), 0-10 11-08 0-10 JOB NAME : POLYGON PLAN 5-B NH - E1Scale: 0.5949 �G /,iRtv,/ �6,0A� WARNINGS: GENERAL NOTES,unless otherwise noted. 44 17 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 1- Truss: E 1 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.2Dn c. assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by �r is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,,r ramp„ NNW"— DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ / 41.,- 4. No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -1 OREGON i SEQ. : 5992808fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, v, ,r, design loads be applied to any component. and are for"dry condition"of use. 45.b'''';'4' 14 20�'` 4 TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if , P fabrication,handling,shipment and installation of components. necessary. JL 7.Designlaesassumes adequate drainage istrus,provided. c„RAIL- 8. A,Lt,, 8,This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 111111111111111111111 TPI WTCA in BCSI,copies of which will be furnished upon request. git coincide with jointacenter lines. e.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPI RES:12/31/2015 IIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS 6-00-00 GIRDER SUPPORTING 20-06-00 IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF p1&BTR LOAD DURATION INCREASE = 1.15 (Non-Rep) 1.2=(-125) 101 1-4=(-54) 72 2-4=(-187) 169 BC: 2x8 KDDF k1&BTR 2.3=( -10) 5 WEBS: 2x4 KDDF STAND LOADING LL = 25 PSF Ground Snow (Pg) TC LATERAL SUPPORT <= 12"0C. UON. TC UNIF LL( 50.0)+DL( 14.0)= 64.0 PLF 0'- 0.0" TO 6'- 0.0" V BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA BC LATERAL SUPPORT <= 12"0C. UON. BC UNIF LL( 231.2)+DL( 177.2)= 408.5 PLF 0'- 0.0" TO 6'- 0.0" V LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) 0'- 0.0" -304/ 1451V -41/ 104H 5.50" 2.32 KDDF ( 625) Single member as shown. LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 6'- 0.0" -302/ 1384V 0/ OH 5.50" 2.21 KDDF ( 625) Hangers attached to the bottom chord REQUIREWINTS OF IBC 2012 AND IRC 2012 NOT BEING MET. will have 1.5" max. nail penetration. ]GOND. 2: Design checked for net(-5 psfl uplift at 24 "oc spacing.] BOTTOM CNORD CHECKED FOR 10PSF LIVE LOAD. TOP #+ For hanger specs. - See approved plans AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. VERTICAL DEFLECTION LIMITS: LL4/240, TL=L/180 Connector platerefix designators: MAX IC PANEL LL DEFL = 0.089" @ 3'- 0.4" Allowed = 0.323" C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc MAX IC PANEL TL DEFL = -0.097" @ 3'- 0.5" Allowed = 0.484" M,M2OHS,M18HS,M16 = MiTek MT series 5-08-04 0-03-12' MAX HORIZ. LL DEFL = 0.000" @ 5'- 8.2" T MAX HORIZ. TL DEFL = 0.000" @ 5'- 8.2" 12 DESIGN ASSUMES MOISTURE CONTENT DOES 6.00 I/ NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting M-1.5x4 3 system and components and cladding criteria. Wind: 140 mph, h=20.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, ii (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), ii load duration factor=1.6, Truss designed for wind loads in the plane of the truss only. CO O V O O') 1 1I / 4 M = O� / f0 �� �1 ** 4 O M-5x16 M-3x10 y y ), 5-08-04 0-03-12 y y 6-00 JOB NAME : POLYGON PLAN 5-B NH - Fl -GIRD Scale: 0.5462 �c,`� pC/,ROF 6'r WARNINGS: GENERAL NOTES,unless otherwise noted: 4 / i+ E -; 1.Builder and erection contractor sh. Id be advised of all General Notes 1.This design is based only upon the parameters shown end is for an individual 1' t( 1" Truss: Fl -GIRD and Warnings before construction ommences. building component.Applicability of design parameters and proper 2.204 compression web bracing mus be installed where shown+, incorporation of component is the responsibility of the building designer. �,r. 3.Additional temporary bracing to i re stability dudng construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector. dditionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by ,t P Y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,r•�Ir�i DATE: 7/11/2014 the overall structure is the respon-'•ility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ # t 4, No load should be applied to any•.mponent until after all bracing and 4. Installation of truss Is the responsibility of the respective contractor. - �y_OREGON kr SEQ. : 5992809 fasteners are complete and at no a should any loads greater than 5.Design assumes trusses ere to be used in a non-corrosive environment, �,. "7 rtlx i's, design loads be applied to any co ponent. and are for"dry condaion"of use. //�. "`�P.- /0 ` +�1;1��' - TRAN S I D: 403334 5.CompuTrus has no control over a ,assumes no responsibiley for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 14, fabrication,handling,shipment an.Installation of components. necessary. •�}1' R p P 7.Design assumes adequate drainage is provided. r7 R t.-�. 6.This design is furnished subject to he limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 111111111111111111 TPI/WTCA in BCSI,copies of wh'• will be furnished upon request. Digit coincide with joint center che. 9. Digits dsize of tplate in inches.. MiTek USA,Inc./CompuTrus software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31.12201...5 1E1110 III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS 6-00-00 GIRDER SUPPORTING 11-08-00 IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TO: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 (Non-Rep) 1.2=(-125) 101 1-4=(-54) 72 2-4=(-187) 169 BC: 2x8 KDDF #1&BTR 2.3=( -10) 5 WEBS: 2x4 KDDF STAND LOADING LL = 25 PSF Ground Snow (Pg) TC LATERAL SUPPORT <= 12"0C. UON. TO UNIF LL( 50.0)+DL( 14.0)= 64.0 PLF 0'- 0.0" TO 6'- 0.0" V BEARING MAX VERT MAX HORZ BAG REQUIRED BRG AREA BC LATERAL SUPPORT <= 12"OC. UON. BC UNIF LL( 120.8)+DL( 102.2)= 223.0 PLF 0'- 0.0" TO 6'- 0.0" V LOCATIONS REACTIONS REACTIONS SIZE SQ,IN. (SPECIES) 0'- 0.0" -170/ 881V -41/ 104H 5.50" 1.41 KDDF ( 625) Single member as shown. LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 6'- 0.0" -175/ 841V 0/ OH 5.50" 1.35 KDDF ( 625) Hangers attached to the bottom chord REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. will have 1.5" max. nail penetration. ICOND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP ** For hanger specs. - See approved plans AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 Connector plate prefix designators: MAX TC PANEL LL DEFL = 0.089" @ 3'- 0.4" Allowed = 0.323" C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc MAX IC PANEL TL DEFL = -0.097" @ 3'- 0.5" Allowed = 0.484" M,M2OHS,M18HS,M16 = MiTek MT series 5-08-04 0-03-12 MAX HORIZ. LL DEFL = 0.000" @ 5'- 8.2" T f . MAX HORIZ. TL DEFL = 0.000" @ 5'- 8.2" 12 DESIGN ASSUMES MOISTURE CONTENT DOES 6.00I/ NOT EXCEED 19% AT TIME OF MANUFACTURE. M-1.5x4 Design conforms to main windforce-resisting 3 system and components and cladding criteria. Wind: 140 mph, h=20.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, g (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), I load duration factor=l.6, Truss designed for wind loads in the plane of the truss only, M O 4 O M M ''/--- INAIIEWillirl o/- 0MMN 4 M-5x16 M-3x10 ** t y y 5-08-04 0-03-12 y y 6-00 JOB NAME : POLYGON PLAN 5-B NH - F2-GIRD Bpale: 0.54620pa°Ptss WARNINGS: GENERAL NOTES,unless otherwise noted: ji///(N j 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual et- 72 r_ EA-- Truss: ^ Truss: F2-GIRD and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2' and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). r�r Amp,DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ ' C/� Ct 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -}y ,4� OREGON 1t/ S E Q L„ �" h.& +s TRANS I D: 403334 design loads be applied to any component. and are for"dry condition"of use. / ,'Q),. .1 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 0 14, �4. fabrication,handling,shipment and installation of components. Dnesign as. 4' R 7.Plates assumes adequate ne dthi ace isprovided.truss, "r rl R�{..� 6.This design is furnished subject to the limitations set forth by B.Plates shall be located on both faces of truss,and placed so their center VIII VIII VIII II II IIII II I IIII IIII III TPIM?CA in BCSI,copies of which will be furnished upon request. git coincideictwith jointcenterche. 9.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXp)RES:12/31/201 1E1110111 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 8'- 8.9" ICOND, 2: Design checked for net(-5 osf) uplift at 24 "oc snacing.l TC: 2x4 KDDF N1&BTR LOAD DURATION INCREASE = 1.15 DESIGN MOISTURE CONTENT DOES BC: 2x4 KDDF k1&BTR SPACED 24.0" O.C. NOT EXCEED ASSUMESEAT SIUR OF MANUFACTURE. TC LATERAL SUPPORT <= 12"OC. UON. LOADING Design conforms to main windforce-resisting BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF system and components and cladding criteria. Connector plate prefix designators: TOTAL LOAD = 42.0 PSF Wind: 140 mph, h=15ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, C,CN,CI8,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LL = 25 PSF Ground Snow (Pg) (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir),load duration factor=1.6, LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL Truss designed for wind loads REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. in the plane of the truss only. BOTTOM CHORD CHECKED FOR tOPSF LIVE LOAD. TOP Gable end truss on continuous bearing wall UON. AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY.AND or equal typical at stud verticals. Refer to CompuTrus gable end detail for 4-04-08 4-04-07 complete specifications. T T 1' 12 12 6.00 I . 6.00 'IM-4x4 3 0 CD 0 Cd 2 4 CO C+) -/O 0/- 0 V o/- 1 _ _ O 0 //////////////////////////////////////////////////////////////////// O M-3x4 M-3x4 y y > 0-10 8-08-15 JOB NAME : POLYGON PLAN 5-B NH - G1 Scale: 0.6079 � ` tO PROFS. WARNINGS: GENERAL NOTES,unless otherwise noted: �± 1.Builder and erection contractor sh uld be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual < ' OP.. E Y" Truss: G 1 and Warnings before construction mmences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing m be installed where shown+, incorporation of component is the responsibility of the building designer. -. 3.Additional temporary bracing to in re stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector. dditlonalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by } po Y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). s,T DATE: 7/11/2014 the overall structure is the respon bility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ SEQ. : 599281 1 4.No load should be applied to any mponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. 7 OREGON tjf fasteners are complete and at no t should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 4.. /' ti �. design loads be applied to any co ponent. and are for"dry condition"of use. "'fix "�fr 2-(1.. TRANS I D: 403334 5.CompuTrus has no control over a assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if �1` 4, fabrication,handling,shipment an installation of components. Dnecessary. '�I ' P P 7.Design assumes adequate drainage is provided. Fi RI 0 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of twos,and placed so their center VIII I I VIII IIII VIII(IIII VIII IIII IIIITPI UVrCA in BCSI,copies of whl will be furnished upon request. lines coincide withjoint centertein lines. 9. Digitsindicate ocsize of cin lines. MiTek USA,Inc./CompuTrus Software 7.6.6(1L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 1111IIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 5'- 3.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1.2=( 0) 42 2-4=(0) 0 BC: 2x4 KDDF N1&BTR SPACED 24.0" O.C. 2.3=(-63) 29 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC, UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 14.2" 0.0" TOTAL LOAD = 42.0 PSF 0'- 0.0" -77/ 404V 0/ 66H 5.50' 0.65 KDDF ( 625) Connector plate prefix designators: 5'- 0.2" 0/ 64V 0/ OH 5.50" 0.10 KDDF ( 625) g LL = 25 PSF Ground Snow (Pg) 5'- 3.0" -58/ 140V 0/ OH 1.50" 0.22 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. ICOND, 2: Design checked for net(-5 osf) uplift at 24 "oc spacing,' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.005" @ -1'- 2,2' Allowed = 0.119" AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.005" @ -1'- 2.2' Allowed = 0.158" MAX IC PANEL LL DEFL = 0.037" @ 3'- 2.1" Allowed = 0.303" MAX TC PANEL TL DEFL = -0.046' @ 3'- 0.0' Allowed = 0.454" MAX HORIZ. LL DEFL = -0.000" @ 5'- 2.2" 12 MAX HORIZ. TL DEFL = -0.000" @ 5'- 2.2" 4.001 3 -/ DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. P. Wind: 140 mph, h=20ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, ,n (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, o Truss designed for wind loads o in the plane of the truss only. M-3x4 `V in c, / - 0 s 0 1 2�� 4>< -/ J, y y . 1-02-04 'PROVIDE FULL BEARING:Jts:2.4,31 5-03 JOB NAME : POLYGON PLAN 5-B NH - G3spate: 0.7536 co or `<C\N 0.n WARNINGS: GENERAL NOTES,unless otherwise noted: (/ �+ 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual t, s{j i. t- -r- Truss: " Truss: G3 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+. Incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). o wpwr DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ *' >It �� /� 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -� OREGON ^N S E Q ses are to be used in a non-corrosive environment, 4 ,1' 5.CompuTrus hes no control over end assumes no responsibility for the TRANS I D: 403334 design loads be applied to any component. and are for"dry condition"of use. Pp 9 42'0 7 V1 6.Design assumes full bearingat all supports shown.Shim or wedge if (a,Q,. fabrication,handling,shipment and installation of components. necessary. 7.Design assumes adequate drainage is provided. "r r;;'R R 1 0-- 6.This design is furnished subject to the limitations set forth by B.Plates shall be located on both faces of truss,and placed so their center 11111111111111111 TPI/WTCA in BCSI,copies of which will be furnished upon request. git coincide with jointcenter lines. 9. Digits indicate size of plate in inches. e MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/201 IIII IIH III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 5'- 3.0" ICOND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.] TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 DESIGN ASSUMES MOISTURE CONTENT DOES BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. NOT EXCEED 19%AT TIME OF MANUFACTURE. TC LATERAL SUPPORT <= 12"OC. UON. LOADING Design conforms to main windforce-resisting BC LATERAL SUPPORT <= 121OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF system and components and cladding criteria. Connector plate prefix designators: TOTAL LOAD = 42.0 PSF Wind: 140 mph, h=15ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, C,CN,CIB,CNIB (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LL = 25 PSF Ground Snow (Pg) (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir),load duration factor=1.6, LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL Truss designed for wind loads REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET, in the plane of the truss only. BOTTOM CHORD CHECKED FOR tOPSF LIVE LOAD. TOP Gable end truss on continuous bearing wall UON. AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. Ror equal typical at stud verticals. er Refer to CompuTrus gable end detail for complete specifications. 12 4.00 V 3 LO 0 0 N 2 to fh / O O� 1 -V 4 M-3x4 y > y 1-02-04 5-03 JOB NAME : POLYGON PLAN 5-B NH - G2 Scale: 0.7728 :0 ,�, WARNINGS: GENERAL NOTES,unless otherwise noted: '..�-r;y 1.Builder and erection contractor shorld be advised of all General Notes 1.This design Is based only upon the parameters shown and is for an individual 4t" l'1.0'241,1 E i-- Truss: Truss: G2 and Warnings before construction,ommences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown 0. incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to Ins re stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector.Additionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by P Y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). , !, DATE: 7/11/2014 the overall structure is the responsbility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 1/ JI. 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. -� OREGON `4/ SEQ. : 5992813 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a noncorrosive environment, L. „l5 /�„ design loads be applied to any component. and are for"dry condition"of use. / -1).-• 2p - TRAN S I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 1 1ty necessary. Mph O fabrication,handling,shipment anoj installation of components. 7.Design assumes adequate drainage is provided. rl R I1. 8.This design is furnished subject to Pe limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 111111111111311111111 TPINVECA in BCSI,copies of whit 1 will be furnished upon request. git coincide with jointinches.9.Digitssinisize of tplate in lines. n C MiTek USA,Inc./CompuTrus Spftware 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 1111 IIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 7'- 1.5" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=(-94) 79 1-4=(-44) 58 2.4=(-233) 166 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2-3=(-10) 4 WEBS: 2x4 KDDF STAND LOADING TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA BC LATERAL SUPPORT <= 12"OC, UON. DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) TOTAL LOAD = 42.0 PSF 0'- 0,0" -34/ 292V -30/ 80H 4.00" 0.47 KDDF ( 625) Connector plate prefix designators: 7'- 1.5" -37/ 307V 0/ OH 5.50" 0.49 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc LL = 25 PSF Ground Snow (Pg) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL ICOND. 2: Design checked for net(-5 nsf) uplift at 24 "oc spacing.I REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX TC PANEL LL DEFL = 0.152" @ 3'- 5.5" Allowed = 0.408" BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX TC PANEL TL DEFL = -0.202" @ 3'- 5.7" Allowed = 0.612" AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX HORIZ. LL DEFL = 0.000" @ 6'- 7.7" 6-07-12 0-05-12f MAX HORIZ. TL DEFL = 0.000" @ 6'- 7.7" 12 DESIGN ASSUMES MOISTURE CONTENT DOES 4.00 NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. M-1.5x4 3 Wind: 140 mph, h=15ft, TCDL=4,2,BCDL=6.0, ASCE 7-10, -r (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 2 load duration factor=l.6, Truss designed for wind loads in the plane of the truss only. to co 0 N I,- Of- .4- 11:11111111111111111111111111111111111111111111111111111111111111111111111 O/- 0 1►►r 111...- 11 4 M-3x4 M-1.5x4 1, y y 6-07-12 0-05-12 J, y 7-01-08 JOB NAME : POLYGON PLAN 5-6 NH - G4 Scale: 0.5588 �c,'� ��,N � :31 WARNINGS: GENERAL NOTES,unless otherwise noted: �{(/./� , i. 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual kr •7 0.• E 1-7- Truss: - T r u s s: G4 and Warnings before construction commences, building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length byAippiP is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). �,f+�miin DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3,2x Impact bridging or lateral bracing required where shown++ Cr ' /� 5992814 n 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -Sy OREGON jt/ SE Q. : 59928 1 4 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, �„ ,./..OREGON j,` design loads be applied to any component, and are for"dry condition"of use. %.' '1 �o . TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 1 P T fabrication,handling,shipment and installation of components. necessary. 7.Designassumes adequate ne drainage iso setl. R RIO- 6. This design is furnished subject to the limitations set forth by 8,Plates shall be located on both faces of truss,and placed so their center 11111111111111111 TPI WTCA in SCSI,copies of which will be furnished upon request. it coincide with jointacenter lines. 9.Digits indicate size of plate in inches. qq MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-7988(MiTek) EXPIRES:12/31i2015 III IIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 5'- 1.5" 'COND. 2: Design checked for net(-5 ssf) uplift at 24 "oc spacing.' IC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 DESIGN ASSUMES MOISTURE CONTENT DOES BC: 2x4 KDDF N1&BTR SPACED 24.0" O.C. NOT EXCEED 19%AT TIME OF MANUFACTURE. TC LATERAL SUPPORT <= 12"OC. UON, LOADING Design conforms to main windforce•resisting BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF system and components and cladding criteria. Connector plate prefix designators: TOTAL LOAD = 42.0 PSF Wind: 140 mph, h=15ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, C,CN,CI8,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LL = 25 PSF Ground Snow (Pg) (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir),load duration factor=1.6, LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL Truss designed for wind loads REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. in the plane of the truss only. BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP Gable end truss on continuous bearing wall UON. AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY.AND or equal typical at stud verticals. Refer to CompuTrus gable end detail for complete specifications. 12 2 -V 4.00 L' rn 0 O N 1 0 O O O/- ////////// ////////////////////////////// - 3 I M-3x4 J, y 5-01-08 JOB NAME : POLYGON PLAN 5-6 NH - G5 Scale: 0.8258 ��_ R0 WARNINGS: GENERAL NOTES,unless otherwise noted: A-�7 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual t,'r� 1p21.� E .1-- Truss: Truss: G5 and Warnings before construction r ommences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing mus be installed where shown+. incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to ins pre stability during construction 2.Design assumes the top and bottom chords to be laterally braced at ✓ DES. BY• BS is the responsibility of the erector.Additionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by ► P y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,NW, DATE: 7/11/2014 the overall structure is the respons bility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. 7 ,q_OREGON ((f SEQ. : 5992815 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, '+r' r�TK 1,,, design loads be applied to any component. and are for"dry condition"of use, l '`� (14 �- TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if �` 1 cry fabrication,handling,shipment anc installation of components. necessary. iii ' y+ P P 7.Designlaesassumes adequate ne dthinac a istrus,provided. —PRO, �,,, 6.This design is furnished subject to he limitations set forth by B.Plates shall be located on both faces of truss,and placed so their center III VIII II I I I IIII VIII I III I I IIII TPI/VVECA in BCSI,copies of whic)will be furnished upon request. git coincide with jointanr lines. 8.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus software 7.6.6(1 L)-Z 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES,12/31/201 5 IIIIIIIIll III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 19'- 10.9" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1.2=( 0) 50 2-8=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" 0.C. 2-3=(•366) 181 3.4=(-259) 116 TC LATERAL SUPPORT <= 12"OC. UON. LOADING 4-5=(-189) 85 BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5.6=(-105) 55 DL ON BOTTOM CHORD = 10.0 PSF 6-7=( -42) 19 OVERHANGS: 12.0" 0.0" TOTAL LOAD = 42.0 PSF Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc LOCATIONS REACTIONS REACTIONS SIZE SG.IN. (SPECIES) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 0'- 0.0" -23/ 377V -78/ 340H 5.50" 0.60 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 5'- 9.2" 0/ 67V 0/ OH 5.50" 0.11 KDDF ( 625) 5'- 11.2" -169/ 346V 0/ OH 1.50" 0.44 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 9'- 11.2" -118/ 231V 0/ OH 1.50" 0.30 KDDF ( 625) AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. 13'- 11.2 -134/ 272V 0/ OH 1.50" 0.35 KDDF ( 625) 17'- 11.2" -107/ 214V 0/ OH 1.50" 0.27 KDDF ( 625) 19'- 10.9" -16/ 33V 0/ OH 1.50" 0.05 KDDF ( 625) 'COND. 2: Design checked for net(-5 nsf) uplift at 24 "oc soacing.' 7-09 12 12-01 03 VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.002" @ -1'- 0.0" Allowed = 0.100" MAX TL CREEP DEFL = -0.003" @ -1'- 0.0" Allowed = 0.133" MAX TC PANEL LL DEFL = -0.031" @ 2'- 11.9" Allowed = 0.397" ;l MAX TC PANEL TL DEFL = -0.051" @ 2'- 11.9" Allowed = 0.596" 6 MAX HORIZ. LL DEFL = -0.007" @ 19'- 10.2" :i MAX HORIZ. TL DEFL = -0.007" @ 19'- 10.2" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19% AT TIME OF MANUFACTURE, 12 5 Design conforms to main windforce-resisting 6.00 dl system and components and cladding criteria. Wind: 140 mph, h=24.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=l.6, 111 c, 4 Truss designed for wind loads M in the plane of the truss only, M-3x6(5) %' o0 3 M O V 0 8 O M-3x4 1, J, y y 0-10 6-00 13-10-15 [PROVIDE FULL BEARING;Jts:2 8.3.4.5.6.71 JOB NAME : POLYGON PLAN 5-6 NH - J10 Scale: 0.2814 \� � , s,0 WARNINGS: GENERAL NOTES,unless otherwise noted: / 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual Ct. !. h+ "Y;' 11 E 1,,,, Truss: J10 and Warnings before construction commences. building component.Applicability of design parameters and properGGGG 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS2'o.c.and at 10'o.c.respectively unless braced throughout their length by Is the responsibility of the erector.Additional permanent bracing of continuous bridgingsheathing such as plywood sheathing(TC)and/or d rywall(BC). J , l .DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact brid9 gor lateral bracing required where shown++ -lift ffI- 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -p' A.OREGON 4r, SEQ. : 5 992816 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, \jx design loads be applied to any component. and are for"dry condition"of use. / y,. C h1 TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 6 /4, 2 4 necessary. {e,[ fabrication,handling,shipment and installation of components. -^ k.- V.. 7.Designassumesadequateon edth drainage is truss, 1 8.This design is furnished subject to the limitations set forth by 8,Plates shall be located on both faces of truss,and placed so their center �R.t t" 1111111111111111111111TPI WfCA in BCS[copies of which will be furnished upon request. git coincideictwithizjointacenter lines. 9.Digits indicate size of plate in inches. EXPIRES: MiTek USA,[n0./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) Lili�(l1C41:12/ 1/2015 1E1111111 IIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 17'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF N1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2-7=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2.3=(-327) 162 3-4=(-220) 97 TC LATERAL SUPPORT <= 12"OC. UON. LOADING 4.5=(-154) 70 BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5-6=( -69) 32 DL ON BOTTOM CHORD = 10.0 PSF OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 0'- 0.0" -23/ 352V -69/ 301H 5.50" 0.56 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 9.2" 0/ 67V 0/ OH 5.50" 0.11 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 5'- 11.2" -168/ 347V 0/ OH 1.50" 0.44 KDDF ( 625) 9'- 11.2" -113/ 224V 0/ OH 1.50" 0.29 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 13'- 11.2' -144/ 295V 0/ OH 1.50" 0.38 KDDF ( 625) AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. 17'- 11.7" -51/ 104V 0/ OH 1.50' 0.17 KDDF ( 625) ICOND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.) VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" 7-09-12 10-01-15 MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" ,r ,r 6/ MAX TC PANEL LL DEFL = 0.030" @ 3'- 7.4" Allowed = 0.397" MAX TO PANEL TL DEFL = -0.051" @ 2'- 11.9" Allowed = 0.596" i MAX HORIZ. LL DEFL = -0.005" @ 17'- 10.9" MAX HORIZ. TL DEFL = -0.005" @ 17'- 10.9" DESIGN ASSUMES MOISTURE CONTENT DOES 5 NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting 12 0 system and components and cladding criteria, 6.00 I/ Wind: 140 mph, h=23.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 4 load duration factor=1.6, Truss designed for wind loads t o in the plane of the truss only. M-31c6(S) oY h co 0. O v 1 rs 7 a Cz M-3x4 k ) J, 0-10 6-00 11-11-11 (PROVIDE FUIL BEARING:Jts:2.7.3,4,5,6I JOB NAME : POLYGON PLAN 5-B NH - J9 Scale: 0.3077 " `�'0 WARNINGS: GENERAL NOTES,unless otherwise noted: Ore fr1 ,-p��f 1.Builder and erection contractor sh uld be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual G C7 M. G.a E -{ Truss: J9 and Warnings before construction ommences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing mu be installed where shown+. incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to In 4ure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector. dditionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by �,,v� x% ► P Y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). „,•�"��.. DATE: 7/11/2014 the overall structure is the respon'bility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 4.No load should be applied to any mponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -y OREGON to SEQ. : 5992817 fasteners are complete and at no me should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 4, "4y` N .. f,,, design loads be applied to any co ponent. and are for"dry condition"of use. //�. '`�y^' 2P ^tt- TRANS I D: 403334 5.CompuTrus has no control over a assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if v 1 , fabrication,handling,shipment an Installation of components. necessary. L:ii--�� \- PP 7.Design assumes adequate drainage is provided +;:',ARO' �„- 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII VIII VIII IIII VIII VIII I III IIII IIII TPI/VJfCA in BCSI,copies of whi h will be furnished upon request. git coincideiitwith jointche. 9.Digitssidsize of tplate in inches.li . MiTek USA,Inc./Con puTrus�oftWare 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 111111III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 15'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF til&BTR LOAD DURATION INCREASE = 1.15 1.2=( 0) 42 2.7=(0) 0 BC: 2x4 KDDF M1&8TR SPACED 24.0" O.C. 2-3=(-287) 142 3-4=(-184) 79 TC LATERAL SUPPORT <= 12"OC. UON. LOADING 4.5=(-108) 58 BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5-6=( -44) 20 DL ON BOTTOM CHORD = 10.0 PSF OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 0'- 0.0" -23/ 353V -61/ 265H 5.50" 0.56 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 9.2" 0/ 67V 0/ OH 5.50" 0.11 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 5'- 11.2" -162/ 343V 0/ OH 1.50" 0.44 KDDF ( 625) 9'- 11.2" -119/ 239V 0/ OH 1.50" 0.31 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 13'- 11.2" -108/ 226V 0/ OH 1.50" 0.29 KDDF ( 625) AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. 15'- 11.7" -15/ 32V 0/ OH 1.50" 0.05 KDDF ( 625) ICOND. 2: Design checked for net(-5 psi) uplift at 24 "oc spacing.( VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX TC PANEL LL DEFL = 0.031" @ 3'- 7.4" Allowed = 0.397" 6 -v MAX TC PANEL TL DEFL = -0.051" @ 2'- 11.9" Allowed = 0.596" h( MAX HORIZ. LL DEFL = -0.004" @ 15'- 10.9" 5 MAX HORIZ. TL DEFL = -0.004" @ 15'- 10.9" DESIGN ASSUMES MOISTURE CONTENT DOES :( NOT EXCEED 19%AT TIME OF MANUFACTURE. 12 Design conforms to main windforce-resisting 6.00 V system and components and cladding criteria. 4 Wind: 140 mph, h=23.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 0 load duration factor=1.6, Truss designed for wind loads Tr in the plane of the truss only. 0 co 3 co O o 17►_„ y O M-3x4 J, ) J, y 0-10 6-00 9-11-11 (PROVIDE FULL BFARING;Jts:2,7,3,4,5,61 JOB NAME : POLYGON PLAN 5-6 NH - J 8Scale: 0.3315 �c,'`�, 0(,N 0 s, IN GENERAL NOTES,unless otherwise noted: 1.Builder and erection contractor should be advised of all General Notes 1.This design Is based only upon the parameters shown and is for an individual ♦f- e. E �4- T r u s s J8 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+. incorporation of component is the responsibility of the building designer. ` 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at ' DES. BY" BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by4410, V is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,,; +fir! ' '�"� DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 1/ r 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -7 OREGON iL SEQ. : 5992818 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, rtik /4 design loads be applied to any component, and are for"dry condition"of use. / 4Q ..}, TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 14, fabrication,handling,shipment and installation of components. necessary. 7.Designlasassumes adequate ne drainagehciso truss, . -' R)��,. 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII VIII((III VIII I II (III VIII(III(III TPI WTCA in BCS(,copies of which will be furnished upon request. lines coincideictwith jointacenter lines. e.Digits indicate size of plate in inches. qq MiTek USA,IDC./COmpuTrug Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES: 2/311201.5 111111 III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 13'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1.2=( 0) 42 2.6=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2.30(-246) 122 3-4=(-148) 61 TC LATERAL SUPPORT <= 12"OC. UON. LOADING 4-5=( -67) 31 BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF OVERHANGS: 10.0" 0.0° TOTAL LOAD = 42.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 0'- 0.0° -24/ 353V -53/ 231H 5.50" 0.57 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 5'- 9.2' 0/ 67V 0/ OH 5.50" 0.11 KDOF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 11.2' -155/ 338V 0/ OH 1.50" 0.43 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 9'- 11.2" -129/ 265V 0/ OH 1.50' 0.34 KDDF ( 625) 13'- 11.7" -51/ 109V 0/ OH 1.50" 0.17 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. ICOND. 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.) VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX TC PANEL LL DEFL = 0.031" @ 3'- 7.4" Allowed = 0.397" 5 MAX TC PANEL TL DEFL = -0.052" @ 2'- 11.9" Allowed = 0.596" MAX HORIZ. LL DEFL = -0.003" @ 13'- 10.9" MAX HORIZ. TL DEFL = -0.003" @ 13'- 10.9" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. 12 6.001/ 4 Design conforms to main windforce-resisting system and components and cladding criteria. 0 Wind: 140 mph, h=22.7ft, TCDL=4.2,BCDL=6.0, ASCE 7.10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, Truss designed for wind loads a• in the plane of the truss only. O 3 1-- 0 I( M O o 1 m 6 , c. M-3x4 „1,_______> y y 0-10 6-00 7-11-11 •;t t ' " . JOB NAME : POLYGON PLAN 5-B NH - J7 Scale: 0.3795 es �''' Qp �d WARNINGS: GENERAL NOTES,unless otherwise noted:. is /),/ -7 1.Builder and erection contractor sho Id be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual CC. 1;G 10 E 's- Truss: "` Truss: J7 and Warnings before construction mmences. building component.Applicabilky of design parameters and proper 2.2x4 compression web bracing mus be installed where shown+. incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to ins re stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector. dditional permanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by Po Y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). „..,'"4111W; DATE: 7/11/2014 the overall structure is the respons ility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 0 (t' 4.No load should be applied to any mponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -1,7, OREGON to SEQ. : 5992819 fasteners are complete and at no ti a should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, ON -.1t-7' fti design loads be applied to any w onent. and are for"dry condition"of use. O }+ 2O �-- TRAN S I D: 403334 5.CompuTrus has no control over an assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if AI 1 ty fabrication,handling,shipment an installation of components. necessary. '✓! ' V P P 7.Designlaesassumes adequate both drainage iso truss, { f 8.This design Is furnished subject to a limitations set forth by B.Plates shall be located on both feces of truss,and placed so their center IIII VIII IIII III IIII IIII MI III) TPI WfCA in BCSI,copies of whicki will be furnished upon request. git coincide with jointcenterche. e. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 1E1111111This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 11'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/C =1 00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 q ' BC: 2x4 KDDF #1&BTR SPACED 24.0" 0.C. 2-3=(-208) 1105 42 2 6 =(0) 0 3-4=(-102) 46 TC LATERAL SUPPORT <= 12"OC. UON. LOADING 4-5=( -38) 18 BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 0'- 0.0" -23/ 352V -45/ 198H 5.50' 0.56 KDDF ( 625) C,CN,CI8,CN18 (or no prefix) = CompuTrus, Inc 5'- 9.2" 0/ 66V 0/ OH 5.50" 0.11 KDDF M,M2OHS,M18HS,M16 = MiTek MT series ( 625) LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 11.2" -159/ 354V 0/ OH 1.50" 0.45 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 9'- 11.2" •92/ 187V 0/ OH 1.50" 0.24 KDDF ( 625) 11'- 11.7" -19/ 46V 0/ OH 1.50" 0.07 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. ICOND. 2: Design checked for net(-5 asfl uplift at 24 "oc spacing.} VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10,0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0' Allowed = 0.111" 5 MAX TC PANEL LL DEFL = -0.030" @ 2'- 11.9" Allowed = 0.397" MAX IC PANEL TL DEFL = -0.050" @ 2'- 11.9" Allowed = 0.596" 0 MAX HORIZ. LL DEFL = -0,002" @ 11'- 10.9" MAX HORIZ. TL DEFL = -0.002" @ 11'- 10.9" 12 4 DESIGN ASSUMES MOISTURE CONTENT DOES 6.001/ ,I NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=22.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, 3 v Truss designed for wind loads o in the plane of the truss only. 0 co M c, C3,L 1 e 6► -V O M-3x4 ,1 ), y y 0-10 6-00 5-11-11 'PROVIDE FULL BEARING;Jts:2,6,3,4,51 JOB NAME : POLYGON PLAN 5-B NH - J6 Scale: 0.4200 'st ,to6's, WARNINGS: GENERAL NOTES,unless otherwise noted: 4.Z? //)/ -T C 1.Builder and erection contractor should be advised of all General Notes 1.This design Is based only upon the parameters shown and is for an individual {'Ct�{r�;*. E Truss: J6 and Warnings before construction commences. building component.Applicability of design parameters and proper TGG 2.2x4 compression web bracing must be installed where shown 0, incorporation of component is the responsibility of the building designer. .✓ 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at y DES. BY: BS Is the responsibility of the erector.Additional permanent bracing of 2'o.c.and at 10'o.c.respectively unless braced throughout their length by continuous sheathing such as plywood in ere and/or tlrywall(SC). wow DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ Th. Ct 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. OREGON ON )�� SEQ. : 5992820 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 7,, 1x V design loads be applied to any component. and are for"dry condition"of use. r'. /N" TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if 1 h fabrication,handling,shipment and installation of components. necessary. it C-� cy,q` 7.Design assumes adequate drainage is provided. +1 R 10." V 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center +D n I IIIA 11111 11111'III MIR VIII III''IIITPI/WTCA in SCSI,copies of which will be furnished upon request. lines coincide with joint center lines. 9.Digits indicate size of plate in inches. 10. cc MiTek USA,InC./CompuTruo Software 7.6.6(1 L)-E For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 9'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF k1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2.5=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2-3= 99 3-4=( -76) 34 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) 0'. 0.0" -22/ 350V -37/ 166H 5.50" 0.56 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 5'- 9.2" 0/ 66V 0/ OH 5.50" 0.11 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 5'- 11.2" -164/ 368V 0/ OH 1.50" 0.47 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 9'- 11.7" -45/ 90V 0/ OH 1.50" 0.14 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP ICOND. 2: Design checked for net(-5 osf) uplift at 24 "oc spacing.I AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX TC PANEL LL DEFL = 0.028" @ 3'- 4.9" Allowed = 0.397" 4 . MAX TC PANEL TL DEFL = -0.048" @ 2'- 11.9" Allowed = 0.596" MAX HORIZ. LL DEFL = -0.002" @ 9'- 10.9" 12 �A' MAX HORIZ. TL DEFL = -0.002" @ 9'- 10.9" 6.00[/ DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. 3 Wind: 140 mph, h=21.7ft, TCOL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6,rjv Truss designed for wind loads o in the plane of the truss only. in r> C?/ v5>< o� 1 0 M-3x4 y ), y y 0-10 6-00 3-11-11 (PROVIDE FULL BEARING:Jts:2,5.3,4I • JOB NAME: POLYGON PLAN 5-B NH - J5 Scale: 0.4887 �, GIN� / WARNINGS: GENERAL NOTES,unless otherwise noted: '� • Il r -F' 1.Builder and erection contractor Mt tuld be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual ' ,cJ/S i-- Truss: J5 and4 Warningsmbeforenbracing g mu commences. buiog aompof ent.component is responsibility spopaoft e s and proper 2.2z4 compression web bracing mull be installed where shown+, incorporationignasna the topent is the mtoof the ally bra designer. 3.Additional temporary bracing to in lure stabilityduringconstruction 2.Design assumes the top and bottom chords to be laterally braced at ,rte. P ry 2'o.c.and at 10'o.c.respectively unless braced throughout their length by ,'^' ,�e�.- DES. BY: BS is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). / " Ct DATE: 7/11/2014 the overall structure is the respon tibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ tM ! ' 4. No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. ,q_OREGON kr SEQ. : 5992821 fasteners are complete and at no Mme should any loads greater than 5.Design assumes trusses are lube used in a non-corrosive environment, �j 47 �,. A, design loads be applied to any celnponent. and are for"dry condition"of use. 1'` 14, tS TRANS I D: 403334 5.CompuTrus has no control over artd assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if ty`` necessary. tt--��t^� V fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. r�R I k.-�'-. 8.This design is furnished subject tc the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 11111 11 11 01 IIII 111 VIII PHI IIII TPI WfCA in BCS(,copies of whi h will be furnished upon request. git coincide with jointpate nr linche. 9. Digitssoncde size oinplateetinches. q MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1958(MiTek) EXPIRES:12/31/2015 1E11 411 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 7'• 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF 418BTR LOAD DURATION INCREASE = 1.15 I.2= ( ) BC: 2x4 KDDF M18BTR SPACED 24.0" O.C. 2-3.(-126) 42 2.5= 0 0 TC LATERAL SUPPORT <= 12"OC. UON. LOADING 3.4=( -64) 25 BC LATERAL SUPPORT <= 12"0C. UON. LL( 25,0)+DL( 7,0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA OVERHANGS: 10.0" 0,0" TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ,IN. (SPECIES) 0'- 0.0" -24/ 353V -29/ 135H 5.50" 0.57 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 5'- 9.2" 0/ 67V 0/ OH 5.50" 0.11 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 5'- 11.2" -142/ 337V 0/ OH 1.50' 0.43 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 7'- 11.7" -13/ OV 0/ OH 1.50' 0.00 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP ICOND. 2: Design checked for net(-5 osfl uplift at 24 "oc soacing.l AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'-•10,0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10,0" Allowed = 0.111" 12 4 MAX TO PANEL LL DEFL = 0.047" @ 2'- 9.3" Allowed = 0.397" MAX TC PANEL TL DEFL = -0.051" @ 2'- 11.9" Allowed = 0.596" 6.00 I/ 01 FA MAX HORIZ. LL DEFL = -0.001" @ 5'- 11.2" MAX HORIZ. TL DEFL = -0.001" @ 7'- 10.9" 3 DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. (11Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=21.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat,2, Exp.B, MWFRS(Dir), o load duration factor=1.6, v Truss designed for wind loads in the plane of the truss only, co O' ck Eli o/- 1 0 �� 5�� M-3x4 1, y y y 0-10 6-00 ,PROVIDE FULL BEARING;Jts:245,3,41 1-11-11 JOB NAME : POLYGON PLAN 5-B NH - J4 Scale: 0.5653 ��' ;�,R° :3' WARNINGS: GENERAL NOTES,unless otherwise noted: 11 :O. 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual {� 1' 11• E `f„- Truss: J4 and Warnings before construction commences. building component.Applicability of design parameters and proper GG 2.204 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. Ail3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at r DES. BY: BS is the responsibility of the erector.Additional permanent bracing of 2'o.c.and at 10'o.c.respectively unless braced throughout their length by continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). `,/" DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2z Impact bridging or lateral bracing required where shown++ 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. OREGON SEQ. : 5992822 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, �� y lz design loads be applied to any component, and are for"dry condition"of use. N A. TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if /h 1n4 0., fa20 brication, fabrication,handling,shipment and installation of components. ecessary. V qq,�. Ui 7.Design assumes adequate ne drainage ioprovided. ill iy RI�..� V 8.This design is furnished subject to the limitations set forth by 8,Plates shall be located on both faces of truss,and placed so their center I VIII,VIII,III,III VIII VIII VIII,III,IIITPUWTCA in BCS,,copies of which will be furnished upon request. lines coincide with joint center lines. 9.Digits indicate size of plate in inches, 10. cc.. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 1E11 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 6'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 IC: 2x4 KDDF N1&BTR LOAD DURATION INCREASE = 1.15 1-2=2.2=(•90) 42 2.4=(0) 0 BC: 2x4 KDDF H1&BTR SPACED 24.0" O.C. TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF 0'. 0.0" -49/ 379V -22/ 104H 5.50" 0.61 KDDF ( 625) 5'- 9.2" 0/ 74V 0/ OH 5.50" 0.12 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 5'- 11.7" -69/ 160V 0/ OH 1.50" 0.26 KDDF ( 625) C,CN,C18,CN1B (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. COND. 2: Design checked for net(-5 Asf) uplift at 24 "oc spacing.) VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083' AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX TC PANEL LL DEFL = 0.079" @ 3'- 7.2" Allowed = 0.395" 5-11-11 MAX TC PANEL TL DEFL = -0.092" @ 3'- 4.8" Allowed = 0.593" '� T MAX HORIZ. LL DEFL = -0.001" @ 5'- 10.9" MAX HORIZ. TL DEFL = -0.001" @ 5'- 10.9" 12 6.00 DESIGN ASSUMES MOISTURE CONTENT DOES 3 -/ NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=20.7ft, TCDL=4.2,BCDL=6.0, ASCE '(-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=l.6, Truss designed for wind loads in the plane of the truss only. v O M CO Of- V O� 1 4� O M-3x4 y y y 0-10 'PROVIDE FULL BEARING:Jts:2.4.31 6-00 JOB NAME : POLYGON PLAN 5-B NH - J3Scale: 0.5843 „C, c 619 "PN, WARNINGS: GENERAL NOTES,unless otherwise noted: 4 .. V 1.Builder and erection contractor sh6uld be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual (' .t. i 1/ E 1-''" Truss: J3 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing murt be installed where shown+, incorporation of component is the responsibility of the building designer. ,r' 3.Additional temporary bracing to in ure stability during construction 2 Design assumes the fop and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector.Additional permanent bracing of 2'o.c.and at 10'o.c.respectively unless braced throughout their length by continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). / `�r +� lliir �� DATE: 7/11/2014 the overall structure Is the respon libility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 1► ' 4. No load should be applied to any lomponent until after all bracing and 4.Installation of truss Is the responsibility of the respective contractor. ,.._OREGON Ix Lit SEQ. : 5992823 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 1 :.. 'y �Q A. design loads be applied to any component. and are for"dry condition"of use. 0 1 4 TRANS I D: 403334 5.CompuTrus has no control over amd assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if {y fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. 4IR R1 l-1^ 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center IIIIII VIII II II VIII VIII VIII VIII I II'III TPINVECA in BCSI,copies of whi h will be furnished upon request. git coincide with jointpate nr linche. 9.Digitssoncde size oinplateetinches. c: MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/S1/2015 I1100IH III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 6'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1,00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2-4=(0) 0 BC: 2x4 KDDF k1&BTR SPACED 24.0" O.C. 2-3=(-63) 49 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25,0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF 0'- 0.0' -41/ 321V -14/ 73H 5.50" 0.51 KDDF ( 625) 3'- 10.9" -99/ 114V 0/ OH 1.50" 0.18 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 6'- 0.0" 0/ 57V 0/ OH 5.50" 0.09 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET, ICOND, 2: Design checked for net(-5 psf) uplift at 24 "oc spacing.I VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" 3-11-11 MAX LL DEFL = 0.000" @ 0'- 0.0' Allowed = 0.078" MAX TC PANEL LL DEFL = 0.012" @ 2'- 2.2' Allowed = 0.246" MAX BC PANEL TL DEFL = -0.034" @ 3'- 1.4" Allowed = 0.333" MAX BC PANEL TL DEFL = -0.004" @ 4'- 1.4" Allowed = 0.333" 12 6.00 I/ MAX HORIZ. LL DEFL = -0.000" @ 3'- 10.9" MAX HORIZ. TL DEFL = -0.000" @ 3'- 10.9" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19% AT TIME OF MANUFACTURE. 3 Design conforms to main windforce-resisting system and components and cladding criteria. 0 Wind: 140 mph, h=20.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=l.6, Truss designed for wind loads v in the plane of the truss only. 0 Cd M O/ •t N � 1 O ►4 M-3x4 0-10 [PROVIDE FULL BEARING;Jts:2.3,41 6-00 JOB NAME: POLYGON PLAN 5-B NH - J2Scale: 0.6394 cc DRRoxss> WARNINGS: GENERAL NOTES,unless otherwise noted: 5`J /tj!�'� 1�+�,, -$y 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual Cts ♦7G 0 ET 1r- Tr u s s: J2 and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. - 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathingsuch as plywood sheathing(TC)and/or d wall BC. ! +1 PYw 9R ) ry ( ) F DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ ♦ J��- 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. 7 A.OREGON ^SJ SEQ. : 5992824 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, L� " � Qn A. design loads be applied to any component. and are for"dry full bearing of use. y r� l�,..�., TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if c✓ 7 4, s necessary. t�R R I�. fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. a� 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 1011111111111111111 TPIM?CA in BCSI,copies of which will be furnished upon request. git coincide with jointcenterche. 9.Digits indicate size of plate in inches. MiTek USA,Inc./CompuTruS Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1068(MiTek) EXPIRES:12/31/2015 111 11 This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 6'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1.2=( 0) 42 2-4=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2-3=(-35) 40 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF 0'- 0.0" -49/ 263V -7/ 43H 5.50" 0.42 KDDF ( 625) 1'- 10.9" -108/ 90V 0/ OH 1.50" 0.14 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 6'- 0.0" 0/ 48V 0/ OH 5.50" 0.08 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. �COND. 2: Design checked for net(-5 osf) uplift at 24 "oc spacing.] VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" 1-11-11 AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX TC PANEL LL DEFL = 0.001" @ 1'- 0.0" Allowed = 0.097" MAX TC PANEL TL DEFL = -0.003" @ 1'- 1.5" Allowed = 0.145" MAX BC PANEL LL DEFL = 0.005" @ 2'- 8.6° Allowed = 0.250" 12 MAX BC PANEL TL DEFL = -0.020" @ 3'- 3.8" Allowed = 0.333" 6.00 1/ MAX HORIZ. LL DEFL = -0.000" @ 1'- 10.9" MAX HORIZ. TL DEFL = 0.000" @ 1'- 10.9" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. 3 Wind: 140 mph, h=19.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, s inuss thedplaneed offor thewind trussoonnly. P- c 0ef- v - - .0 O� 1 2� <4 M-3x4 0-10 'PROVIDE FULL BEAR NG:Jts:2.3,41 6-00 JOB NAME: POLYGON PLAN 5-B NH - J1 Scale: 0.7144 0 PRQ ,f ,� c/,Iry r.„ QWARNINGS: GENERAL NOTES,unless otherwise notetl: 4,Z? C/t 1 , 1 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 4t' JRGh t"J, i- Truss: J1 and Warnings before construction kommences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing mus be Installed where shown+. incorporation of component is the responsibility of the building designer. r' 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at ! DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by � I► is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ter.r , DATE: 7/11/2014 the overall structure is the responsbility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. •Sy OREGON /4" SEQ. : 5992825 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 1." �' e`T" design loads be applied to any component. and are for"dry condition"of use. / "/�" 2,Q TRANS I D: 403334 5.CompuTrus has no control over end assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if V 14„ necessary. , fabrication,handling,shipment an installation of components. 7.Design assumes adequate drainage is provided. fit R I L 8,This design is furnished subject to he limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center VIII VIII VIII IIII VIII VIII VIII III IIII TPI WfCA in BCSI,copies of which will be furnished upon request. git coincide with jointcenter nche. 9. Digits dsize of plate in inches. p MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 13'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF 41&BTR LOAD DURATION INCREASE = 1.15 1- 2=( 0) 42 2- 8=( -97) 190 8- 7=( 0) 18 BC: 2x4 KDDF 41&BTR SPACED 24.0" O.C. 2- 3=(-257) 48 7- 9=(-158) 297 7- 3=( 0) 49 WEBS: 2x4 KDDF STAND 3- 4=(-224) 105 3. 9=(-308) 164 TC LATERAL SUPPORT <= 12"OC. UON. LOADING 4. 5=(-153) 67 BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5- 6=( -68) 32 DL ON BOTTOM CHORD = 10.0 PSF TOTAL LDAD = 42.0 PSF OVERHANGS: 10.0" 0.0" BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) g 0'- 0.0" -29/ 351V -53/ 231H 5.50" 0.56 KDDF ( 625) C,CN,CI8,CN18 (or no prefix) = CompuTrus, Inc LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 2.3" 0/ 127V 0/ OH 5.50" 0.20 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 5'- 10.9" -120/ 259V 0/ OH 1.50" 0.33 KDDF ( 625) 9'- 10.9" -137/ 286V 0/ OH 1.50" 0.37 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP 13'- 11.7" -50/ 106V 0/ OH 1.50" 0.17 KDDF ( 625) AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. 'COND. 2: Design checked for net(-5 osfl uplift at 24 "oc spacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111' MAX LL DEFL = 0.008" @ 2'- 3.8" Allowed = 0.254" 13-11-11 MAX TL CREEP DEFL = -0.015" @ 2'- 3.8" Allowed = 0.339" T f MAX HORIZ. LL DEFL = -0.007" @ 5'- 2.3" -s MAX HORIZ. TL DEFL = 0.009" @ 5'- 2.3" :t DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19% AT TIME OF MANUFACTURE. ' 12 Design conforms to main windforce-resisting 6.00 system and components and cladding criteria. I/ Wind: 140 mph, h=22.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 1,1 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), co load duration factor=1.6, o Trust designed for wind loads 'r o in the plane of the truss only. 0 r` CO 0 M-4x6 Eek co M 3x4 �ii _ o 9 -/ /- o 0r��m M-3x4o O s1 0 N M-3x4 M-1.5x4 N ), r Y Y 2-03-12 2-10-08 0-09-12 ), .1 ), y 0-101, 2-05-08 y 11-06-03 6-00 7-11-11 'PROVIDE FULL BEARING:Jts:2,9,4,5,6' JOB NAME : POLYGON PLAN 5-6 NH - J 7CScale: 0.3025 `�4 C1l+v R° :..9 WARNINGS: GENERAL NOTES,unless otherwise noted: `{((///r� -y`'" 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual et" t 7G e+ E Truss: J 7C and Warnings before construction commences. building component.Applicability of design parameters and proper G 2.2x4 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by is the responsibility of the erector.Additional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). , e' ,r., "" DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 111 C 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -7 OREGON 1,1 SEQ. : 5992826 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, L„ _„/. \fpr A design loads be applied to any component. and are for"dry condition"of use. iii- "4:-, �(� ,.5 TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if 0 14, V fabrication,handling,shipment and installation of components. necessary. /li 7.Design assumes adequate drainage is provided. -�--RAO' 6.This design is furnished subject to the limitations set forth by B.Plates shall be located on both faces of truss,and placed so their center I IIIIII VIII VIII IIII I II IIII VIII IIII IIIITPI/WTCA in BCSI,copies of which will be furnished upon request. lines coincide with joint center lines. 9.Digits indicate size of plate in inches. r-y ❑ MiTek USA,Inc./CompuTrus Software+7.6.6(1L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 01.5 11111111 III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 9'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 I. 2=( 0) 42 2- 8=(-102) 178 8- 7=( 0) 18 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2- 3=(-245) 43 7- 9=(-165) 278 7- 3=( 0) 49 WEBS: 2x4 KDDF STAND 3- 4=(-213) 71 3- 9=(-289) 171 LOADING 4. 5=(-155) 77 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF 5. 6=(-101) 0 BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF TOTAL LOAD = 42.0 PSF OVERHANGS: 10.0" 24.0' BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA LL = 25 PSF Ground Snow (Pg) LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) Connector plate prefix designators: 0'- 0.0" -27/ 356V -39/ 215H 5.50" 0.57 KDDF ( 625) C,CN,CI8,CN18 (or no prefix) = CompuTrus, IncLIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 2.3" 0/ 122V 0/ OH 5.50" 0.20 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series5'- 10.9" -136/ 299V 0/ OH 1.50" 0.38 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 9'- 11.7" -183/ 405V 0/ OH 1.50" 0.52 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. ICOND, 2: Design checked for net(-5 ssf) uplift at 24 "oc spacing.) VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = 0.009" @ 2'- 3.8" Allowed = 0.254" MAX TL CREEP DEFL = -0.014" @ 2'- 3.8" Allowed = 0.339" 11 11 11 MAX LL DEFL = 0.042" @ 11'- 11.7" Allowed = 0.200" f '( MAX TL CREEP DEFL = -0.048" @ 11'- 11.7" Allowed = 0.267" f- MAX HORIZ. LL DEFL = -0.007" @ 5'- 2.3" MAX HORIZ. TL DEFL = 0.009" @ 5'- 2.3" DESIGN ASSUMES 12 NOTEXCEED9%ATTITIMEEOFODOES MANUFACTURE. 6.001/ 0 Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=22.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, o (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), v o load duration factor=1.6 O - Truss designed for wind loads m IV in the plane of the truss only. M-4x6 p M-3x4oo 0 98 , -/ ,� o = a 8 M-3x4 m.1.51(4o o M-3x4 1 ), 2-03-12 2-10-08 0-09-12 1, 1 1 1 0-10, 2-05-08 , 9-06-03 1 6-00 5-11-11 (PROVIDE FULL BEARING:Jts:2,9,4,51 pc- JOB NAME : POLYGON PLAN 5-B NH - J6CScale: 0.3429 ,, ,I+vic61r4, WARNINGS: GENERAL NOTES,unless otherwise noted: fl 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual Ct02•• E fe Truss: J 6C and Warnings before construction:ommences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing musk be installed where shown+, incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to in�nre stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector,hdditionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by e P Y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,r +tea,< , DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact budging or lateral bracing required where shown++ 4. No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. OREGON gr SEQ. : 5992827 fasteners are complete and at no tine should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, " .. ' V.N��A, design loads be applied to any component. and are for"dry condition"of use. )" TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if p� 14, fabrication,handling,shipment and installation of components. Dnecessary. 'a'lu" P 7.Design assumes adequate drainage is provided. R R O 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 111111 VIII VIII(III VIII VIII VIII(III(III TPIMffCA in BCS(,copies of which will be furnished upon request. git coincideitwithzjointche. 9.Digitssii dsize of tplate in inches.li . MiTek USA,Inc./CompuTrus Dftware+7,6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES-,12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 9' =1.00 - 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/C TC: 2x4 KDDF 41&BTR BC: 2x4 KDDF q1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2-7=( -69) 178 7.6=( 0 0) 18 WEBS: 2x4 KDDF STAND SPACED 24.0" O.C. 2-3=(-245) 43 6-8=(-114) 278 6.3=( 0) 49 3-4=(-153) 71 3-8=(-289) 118 TC LATERAL SUPPORT <= 12"OC. UON. LOADING 4-5=( -70) 32 BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BOG AREA LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 0'- 0.0" -27/ 347V -37/ 166H 5.50" 0.55 KDDF ( 625) C,CN,CI8,CN18 (or no prefix) = CompuTrus, Inc 5'- 2.3" 0/ 122V 0/ OH 5.50" 0.20 KDDF ( 625) M,M20HS,M18HS,M16or = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 10.9" -138/ 301V 0/ OH 1.50" 0.39 KDDF ( 625) REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. 9'- 11.7" -49/ 103V 0/ OH 1.50" 0.16 KDDF ( 625) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP ICOND. 2: Design checked for net(-5 pst) uplift at 24 "oc spacin I AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. 0• VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = -0.007" @ 2'- 3.8" Allowed = 0.254" MAX TL CREEP DEFL = -0.014" @ 2'- 3.8" Allowed = 0.339" 9-11-11 MAX HORIZ. LL DEFL = -0.005" @ 5'- 2.3" T f MAX HORIZ. TL DEFL = 0.009" @ 5'- 2.3" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. 6.00 12 -( Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=21.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), • load duration factor=1.6, p Truss designed for wind loads o �� 0 in the plane of the truss only. o Ch M-4x6 07Idgilliar co0o o w�i M-1.5x4 -/(i. w 7 M-3x4 o M-3x4 M-3x4 0 y y y y 2-03-12 2-10-08 0-09-12 ,, y y y 0-10 , 2-05-08 7-96-03 y 6-00 3-11-11 (PROVIDE FULL BEARING;Jts:2.8,4,51 JOB NAME : POLYGON PLAN 5-B NH - J5C Scale: 0.3783 d` GN pc.,'i WARNINGS: GENERAL NOTES,unless otherwise noted: X45✓` + "T D-s.^ /� 1.Builder end erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual17 Truss: J 5C and Warnings before construction commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing must be installed where shown+. incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector.Additional permanent bracing of 2'o.c.and at 10'Sc.. respectively unless braced throughout their length by #ry�� continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ;/'ter, W;,. wn""" DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ Ct. 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. #' OREGON f SEQ. : 5992828 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, �L design loads be applied to any component. and are for"dry condition"of use. \ A. TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge If /0 ' }` '1 4, 2p. h. fabrication,handling,shipment and installation of components. necessary. 'y,Q` 7.Design assumes adequate drainage is provided. 'r7 'R R I Lx- V 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center rD rr�l 111111111111011111111110.TPI/WTCA in BCSI,copies of which will be furnished upon request. lines coincide with joint center lines 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software+7.6.6(1 L)-E For basic connector plate design values see ESR-1311,ESR-1989(MiTek) EXPIRES 12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 6'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1.2=( 0) 42 2.7=( -84) 228 7.6=( 0) 18 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2-3=(-297) 65 6-8=(-138) 358 6-3=( 0) 50 WEBS: 2x4 KDDF STAND 3-4=(-153) 82 3-8=(-372) 143 LOADING 4.5=(-100) 0 TC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SO.IN. (SPECIES) OVERHANGS: 10.0" 23.7" 0'- 0.0" -35/ 328V -24/ 151H 5.50" 0.53 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 5'- 2.3" 0/ 144V 0/ OH 5.50" 0.23 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL 5'- 11.7" -182/ 415V 0/ OH 1.50" 0.53 KDDF ( 625) M,M2OHS,M18HS,M16 = MiTek MT series REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. ICOND. 2: Design checked for net(-5 osfl uplift at 24 "oc soacing.l BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX LL DEFL = -0.010" @ 2'- 3.8" Allowed = 0.254" MAX TL CREEP DEFL = -0.018" @ 2'- 3.8" Allowed = 0.339" MAX LL DEFL = 0.041" @ 7'- 11.7' Allowed = 0.197" MAX TL CREEP DEFL = -0.047" @ 7'- 11.7" Allowed = 0.263" -11-11 T MAX HORIZ. TL DEFL = 0.011" @ 5'- 2.3" s 12 DESIGN ASSUMES MOISTURE CONTENT DOES 6.00(/ NOT EXCEED 19% AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=21.2ft, TCDL=4,2,BCDL=6.0, ASCE 7-10, o (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, o Truss designed for wind loads o in the plane of the truss only. v M-4x6 " 10101111111111 M-3x4Paw c0C. 0 BI _I_ 8 �Z �ci' ul o c. M-3x' M-1.5x4 o 2= Ca 7 c. 0 M-3x4 ; y ), > 2-03-12 2 10-08 0-09-12 y y ), J, 0-10 y 2-05-08 5 06 03 y 6-00 1-11-11 (PROVIDE FULL BEARING:Jts:2,8., JOB NAME : POLYGON PLAN 5-B NH - J4C � `�� p+RO09 Scale: 0.4268 / AA� r /0 WARNINGS: GENERAL NOTES,unless otherwise noted: , 'Y-'f, 1.Builder and erection contractor sh.uld be advised of all General Notes 1.This design is based only upon the parameters shown end is for an individual s r Truss: J 4C and compress before bracingconstructionm be insnces. bincorporgation component.omponen is thity responsibility spoign para mete s untl proper 2.2x4 compression web bracing mu be installed where shown+, Design assu af the topent is the moof the ally designer. fir' 3.Additional temporary bracing to in ere stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS 2'o.c.and at 10'o.c.respectively unless braced throughout their length by Iii" is the responsibility of the erector. dd8ional permanent bracing of continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). �' DATE: 7/11/2014 the overall structure is the respon ibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ ♦ + 4.No load should be applied to any .mponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. ,,,4��+�OREGON �, Lei SEQ. : 5992829 fasteners are complete and at no me should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, 14_,,n." k t A. design loads be applied to any co ponent. and are for"dry condition"of use. V 14 '�, TRANS I D: 403334 5.CompuTrus has no control over a d assumes no responsibility for the 8.Design necessary.assumes full bearing at all supports shown.Shim or wedge if ry, fabrication,handling,shipment a .installation of components. v p p 7.Design assumes adequate drainage Is provided. L Ft R 11..�'. 6.This design is furnished subject I.the limitations set forth by 6.Plates shall be located on both faces of truss,and placed so their center VIII VIII VIII(III VIII VIII VIII(III(III TPI/WTCA In BCSI,copies of whl�h will be furnished upon request. lines coincide with joint center che. 9. Digits dsize of plate ein inches.. MiTek USA,Inc./CompuTrus Software+7,6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 IIIIIIIIIIIIII This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 6'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2.6=(-135) 228 6.5=( 0) 18 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2.3=(•297) 65 5-7=(•218) 358 5.3=( 0) 50 WEBS: 2x4 KDDF STAND 3.4=( -55) 41 3-7=(-372) 226 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) 0'- 0,0" -48/ 365V -22/ 104H 5,50" 0.58 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 5'- 2.3' 0/ 144V 0/ OH 5.50" 0.23 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc 5'- 11.7" -48/ 108V 0/ OH 1.50" 0.17 KDDF ( 625) M,M20HS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. [COND. 2: Design checked for nett-5 nsf) uplift at 24 "oc spacing,] BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX LL DEFL = 0.001' @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = •0.001" @ 0'--10.0" Allowed = 0,111" MAX LL DEFL = 0.012" @ 2'- 3.8" Allowed = 0.254" MAX TL CREEP DEFL = -0.018' @ 2'- 3.8" Allowed = 0,339" MAX HORIZ. LL DEFL = -0.009" @ 5'- 2.3" 5-11-11 MAX HORIZ. TL DEFL = 0.011' @ 5'- 2.3" T T DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. 12 6.00/ Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=20.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, 0 (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), load duration factor=1.6, Truss designed for wind loads in the plane of the truss only. co0 v M-4x6 0 0 co Cd _M-3x4 (h e1a' 11111 co /- C,'/- 2 �'-�Em' M-3x4 M-1.5x4 �o 0 M-3x4 y ), > y 2-03-12 2-10-08 0-09-12 y ), y )- 0-10 2-05-08 6-00 3-06-08 [PROVIDE FULL BEARING;Jts:2,7,4] JOB NAME : POLYGON PLAN 5-B NH - J3C Scale: 0.4902 `c,5 O PR o,,0 WARNINGS: GENERAL NOTES,unless otherwise noted: C,.,1' (/ "T 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and Is for an individual ��`` L A e E fit,, Truss: J 3C and Warnings before construction commences. building component.Applicability of design parameters and proper LLLL 2.204 compression web bracing must be installed where shown+, incorporation of component is the responsibility of the building designer. DES. BY: BS 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at is the responsibility of the erector.Additional permanent bracing of 2'o.c.and at 10'o.c.respectively unless braced throughout their length by � „ continuous sheathing such as plywood here)and/or drywall(BC). ��.- • DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ 40 4.No load should be applied to any component until after all bracing and 4. Installation of truss is the responsibility of the respective contractor. OREGON 'I� SEQ. : 5992830 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, " W design loads be applied to any component, and are for"dry condition"of use. �+' "� �. TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if r 1 fabrication,handling,shipment and installation of components. necessary. iy 7.Design assumes adequate drainage is provided. '✓ley ry, V II VIII VIII VIII VIII VIII MEI IIII 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center n TPI/WfCA in BCS[,copies of which will be furnished upon request. lines coincide with joint center lines. 9. Digits indicate size of plate in Inches. MiTek USA,Inc./CompuTrus Software+7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 IIIIIIII (III This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 6'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 IC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2-6=(-46) 123 6-5=( 0) 18 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2.3=(-188) 24 5.7=(-76) 191 5-3=( 0) 48 WEBS: 2x4 KDDF STAND 3.4=( -22) 28 3-7=(-198) 79 LOADING TC LATERAL SUPPORT <= 12"0C. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BC LATERAL SUPPORT <= 12"OC. UON. DL ON BOTTOM CHORD = 10.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA TOTAL LOAD = 42.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 10.0" 0.0" 0'- 0.0" -48/ 325V -14/ 73H 5.50" 0.52 KDDF ( 625) LL = 25 PSF Ground Snow (Pg) 3'- 10.9" -84/ 70V 0/ OH 1.50" 0.11 KDDF ( 625) Connector plate prefix designators: 6'- 0.0" 0/ 98V 0/ OH 5.50" 0.16 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL M,M2OHS,M18HS,M16 = MiTek MT series REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. ICOND. 2: Design checked for net(-5 Pe) uplift at 24 "oc spacing.) BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX LL DEFL = 0.001' @ 0'--10.0" Allowed = 0.083" MAX TL CREEP DEFL = -0.001" @ 0'--10.0' Allowed = 0.111" MAX LL DEFL = 0.005" @ 2'- 3.8" Allowed = 0.170" MAX TL CREEP DEFL = -0.010" @ 2'- 3.8" Allowed = 0.226' MAX LL DEFL = 0.000" @ 5'- 2.3" Allowed = 0.078" MAX BC PANEL TL DEFL = -0.002" @ 3'- 11.9" Allowed = 0.128" 3-11-11 MAX HORIZ. LL DEFL = -0.004" @ 5'- 2.3" MAX HORIZ. TL DEFL = 0.006" @ 5'- 2.3" 12 DESIGN ASSUMES MOISTURE CONTENT DOES 6.00 I/ NOT EXCEED 199s AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. A- -/ Wind: 140 mph, h=20.2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10t (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), FA co load duration factor=l.6, M 4X8 Truss designed for wind loads O in the plane of the truss only. N M-3x4 = co 5 o/- i ll 7 -/ a is M-3x4 o M-1.5x4 � 2 oo M-8x4 O y f I I 2-03-12 2-10-08 0-09-12 ) I I I 0-10 2-05-08 6-00 3-06-08 'PROVIDE FULL BEARING:JtI:2.4,71 JOB NAME : POLYGON PLAN 5-B NH - J2C ,� � NO f, Scale: 0.5343 / WARNINGS: GENERAL NOTES,unless otherwise noted: 17`}�, r�/� It 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual i A E Truss: J2C and Warnings before construction commences. building component.Applicability of design parameters and proper 2.204 compression web bracing must be installed where shown*. Incorporation of component is the responsibility of the building designer. ,rr' 3.Additional temporarybracing to In:ure stabilityduring construction 2.Design assumes the top and bottom chords to be laterally braced at 2'o.c.and at 10'o.c.respectively unless braced throughout their length by �, ' DES. BY: BS Is the responsibility of the erector.Additional permanent bracing of continuous sheathingsuch as plywood sheathing(TC)C and/or d all BC. �! DATE: 7/11/2014 r cw gR s ryw ( ) the overall structure is the respoMibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ I ��` SEQ. : 5992831 4. No load should be applied to any omponent until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. ^S7 q_OREGON fasteners are complete and at no mme should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, G_ 4 4. 14, Z�\ . design loads be applied to any component. and are for"dry condition"of use. 1 4 Ce.)‘*.TRANS I D: 403334 5.CompuTrus has no control over a assumes no responsibility for the 6.Design assumes full bearing at all supports shown.Shim or wedge if V`' fabrication,handling,shipment and installation of components. ry. Cy Rr7 p P 7.Design assumes adequate drainage is providedrl rll"'. 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center (IIII 11111 (IIII 1111 (IIII(IIII111111 IIIIIIIIIII TPI VUfCA in BCS(,copies of whi h will be furnished upon request. git coincideictwith jointcenter che. 9.Digits insize of platein inches.. MiTek USA,Inc./CompuTrus Software+7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015 111111 IIS This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 3'- 11.7" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 IC: 2x4 KDDF 41&BTR LOAD DURATION INCREASE = 1.15 1-2=( 0) 42 2.4=(0) 0 BC: 2x4 KDDF 41&BTR SPACED 24.0" 0.C. 2-3=(-68) 30 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX HORZ BRG REQUIRED BRG AREA DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SQ.IN. (SPECIES) OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF 0'- 0.0" -58/ 287V -14/ 73H 5.50" 0.46 KDDF ( 625) I 1'- 9.2" -3/ 60V 0/ OH 5.50" 0.10 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 3'- 11.7" -44/ 94V 0/ OH 1.50" 0.15 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. ICOND. 2: Design checked for net(-5 nsf) uplift at 24 "oc soacing.' VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" MAX BC PANEL LL DEFL = 0.002" @ 1'- 0.1" Allowed = 0.050" MAX BC PANEL TL DEFL = -0.002" @ 1'- 0.1" Allowed = 0.067" 12 3 MAX HORIZ. LL DEFL = -0.000" @ 3'- 10.9" 6.00 / MAX HORIZ. TL DEFL = -0.000" @ 3'- 10.9" 11 DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=20,2ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, v (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), o load duration factor=l.6, w Truss designed for wind loads in the plane of the truss only. Chi O o O 0 1 2' 4 WWII M-3x4 0-10 2-00 1-11-11 'PROVIDE FULL BEARING;Jts:2,4,31 JOB NAME : POLYGON PLAN 5-B NH - ASJ 2Sale: 0.6541 N° sil itA. WARNINGS: GENERAL NOTES,unless otherwise noted: �J I "Y 1.Builder and erection contractor should be advised of all General Notes 1.This design is based only upon the parameters shown and is for an individual 'Ct. yt(//,/ T ""?i, E f,-. Truss: ASJ 2 and Warnings before construction commences. building component.Applicability of design parameters and proper • 2.204 compression web bracing must be installed where shown+. incorporation of component is the responsibility of the building designer. 3.Additional temporary bracing to insure stability during construction 2.Design assumes the top and bottom chords to be laterally braced at DES. BY: BS is the responsibility of the erector.Additionalpermanent bracingof 2'o.c.and at 10'o.c.respectively unless braced throughout their length by continuous P Y continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). J'�", DATE: 7/11/2014 the overall structure is the responsibility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ -4111 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -7C)REGQN to S E Q Design1. n assumes trusses are to be used in a non-corrosive environment, " ".-7 "! /," design loads be applied to any component. end are for"dry condition"of use. / -q N- 2- TRANS I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the 8.Design assumes full bearing at all supports shown.Shim or wedge if AI 14; c� necessary. 'Vl `} fabrication,handling,shipment and installation of components. 7.Design assumes adequate drainage is provided. Fi A 11- 6.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 1111111111111111 TPI/WTCA in BCS',copies of which will be furnished upon request. lines coincide with joint ate inr lines. 9.lives indicate size of plate in inches. MiTek USA,Inc./CompuTrus Software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXP(RES:12//31/201.5 1E IIIIIIII I This design prepared from computer input by PACIFIC LUMBER-BC LUMBER SPECIFICATIONS TRUSS SPAN 2'- 0.0" IBC 2012 MAX MEMBER FORCES 4WR/DDF/Cq=1.00 TC: 2x4 KDDF #1&BTR LOAD DURATION INCREASE = 1.15 1-2=( -3) 42 2.4=(0) 0 BC: 2x4 KDDF #1&BTR SPACED 24.0" O.C. 2-3=(-45) 15 TC LATERAL SUPPORT <= 12"OC. UON. LOADING BC LATERAL SUPPORT <= 12"OC. UON. LL( 25.0)+DL( 7.0) ON TOP CHORD = 32.0 PSF BEARING MAX VERT MAX NORZ BRG REQUIRED BRG AREA DL ON BOTTOM CHORD = 10.0 PSF LOCATIONS REACTIONS REACTIONS SIZE SO.IN. (SPECIES) OVERHANGS: 10.0" 0.0" TOTAL LOAD = 42.0 PSF 0'- 0.0" -62/ 263V -7/ 43H 5.50" 0.42 KDDF ( 625) 1'- 9.2" -18/ 21V 0/ OH 5.50" 0.03 KDDF ( 625) Connector plate prefix designators: LL = 25 PSF Ground Snow (Pg) 1'- 11.7" -18/ 42V 0/ OH 1.50" 0.07 KDDF ( 625) C,CN,C18,CN18 (or no prefix) = CompuTrus, Inc M,M2OHS,M18HS,M16 = MiTek MT series LIMITED STORAGE DOES NOT APPLY DUE TO THE SPATIAL REQUIREMENTS OF IBC 2012 AND IRC 2012 NOT BEING MET. ICOND. 2; Design checked for net(-5 osfl uplift at 24 "oc soacing.l VERTICAL DEFLECTION LIMITS: LL=L/240, TL=L/180 BOTTOM CHORD CHECKED FOR 10PSF LIVE LOAD. TOP MAX LL DEFL = 0.001" @ 0'--10.0" Allowed = 0.083" 1-11-11 AND BOTTOM CHORD LIVE LOADS ACT NON-CONCURRENTLY. MAX TL CREEP DEFL = -0.001" @ 0'--10.0" Allowed = 0.111" T MAX BC PANEL LL DEFL = 0.001" @ 1'- 0.1" Allowed = 0.050" MAX TC PANEL TL DEFL = -0.001" @ 1'- 2,9" Allowed = 0.145" 12 MAX HORIZ. LL DEFL = -0.000" @ 1'- 10.9" 6.001/ MAX HORIZ. TL DEFL = -0.000" @ 1'- 10.9" DESIGN ASSUMES MOISTURE CONTENT DOES NOT EXCEED 19%AT TIME OF MANUFACTURE. Design conforms to main windforce-resisting system and components and cladding criteria. Wind: 140 mph, h=19.7ft, TCDL=4.2,BCDL=6.0, ASCE 7-10, (All Heights), Enclosed, Cat.2, Exp.B, MWFRS(Dir), 3 -/ load duration factor=1.6, Truss designed for wind loads in the plane of the truss only, c 0 CO o/- v - - 0 o� 1 -...i....- 4 T M-3x4 > y 1, 0-10 2-00 (PROVIDE FULL BEAR NG:Jts:2,4,31 JOB NAME : POLYGON PLAN 5-6 NH - ASJ1 Scale: 0.7139 el so N OFA�'r WARNINGS: GENERAL NOTES,unless otherwise noted: CO 1 -p��- 1.Builder and erection contractor should be advised of all General Notes 1.This design Is based only upon the parameters shown and is for an individual 44- S{ ^'j p 11 E -r Truss: ASJ 1 end Warnings before construction Commences. building component.Applicability of design parameters and proper 2.2x4 compression web bracing mus be installed where shown+, incorporation of component is the responsibility of the building designer. .,r 3.Additional temporary bracing to Imre stability during construction 2.Design assumes the top and bottom chords to be laterally braced at �" DES. BY: BS is the responsibility of the erector.Additional permanent bracing of 2'o.c.and at 10'o.c.respectively unless braced throughout their length by continuous sheathing such as plywood sheathing(TC)and/or drywall(BC). ,,..--� s DATE: 7/11/2014 the overall structure is the responstility of the building designer. 3.2x Impact bridging or lateral bracing required where shown++ *' !(�t� 4.No load should be applied to any component until after all bracing and 4.Installation of truss is the responsibility of the respective contractor. -� OREGON ^<l SEQ. : 5992833 fasteners are complete and at no time should any loads greater than 5.Design assumes trusses are to be used in a non-corrosive environment, .- .t + design loads be applied to any component. and are for"dry condition"of use. /' ,'44, r�t} - TRAN S I D: 403334 5.CompuTrus has no control over and assumes no responsibility for the B.Design assumes full bearing at all supports shown.Shim or wedge if 0pI 14, necessary. '✓! PRO,' f Qi fabrication,handling,shipment ant installation of components. 7.Design assumes adequate drainage is provided. C l.• 8.This design is furnished subject to the limitations set forth by 8.Plates shall be located on both faces of truss,and placed so their center 111111111111111111111 7PI/WfCA in BCSI,copies of whist will be furnished upon request. git coincide with jointacenter lines. 9. Digits indicate size of plate in inches. MiTek USA,Inc./CompuTrus software 7.6.6(1 L)-E 10.For basic connector plate design values see ESR-1311,ESR-1988(MiTek) EXPIRES:12/31/2015