PFI2018-00273 IsSW
CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
COMMUNITY DEVELOPMENT Permit#: PF12018-00273
13125 Hall Blvd., Tigard OR 97223 503.718.2421 Date Issued: 10/10/2018
Parcel: SEG3846
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: PGE
Project Description: Adjacent to Roy Rogers Rd and Scholls Ferry Rd. Install alum fluted poles and acorn lights. PGE
M2588168.
Owner: FEES
Description Date Amount
PHONE:
Contractor:
PHONE:
FAX:
Applicant:
RODRIGO SOLIS
10800 SW AVERY ST
TUALATIN, OR 97062
PHONE: 503-464-7777
Total $0.00
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant ��� A ��1 � �O
Signature: 1���/� �f
Issued By:
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12018-00273
Type: Condition Name: Status: Severity:
PFI Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of
any agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited
and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up
and suspension of work to accomplish clean-up.
PFI Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be
reinstalled or replaced, with like kind of material. Obtain City approval of restoration work.
PFI Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition, American Traffic Safety Services
Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work
area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be
effectively maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time, without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and
area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire& Rescue) and to 503-962-8140(Tri-Met)
and 503-431-2345(Tigard School District) and other service providers impacted by such closure.
PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the
City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized
by the City Engineer.
PFI—Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987.
If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work (pothole
before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at
the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work
with affected utility agencies.
PFI_Utilities 14-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI—Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities (roads, ditches, etc.) as may be necessary, as determined by
the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name> at<Insert
Phone#>, to establish a preconstruction meeting.
PFI_Utilities 17 -NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work; prior to any staged
inspection, and after completing work covered by the permit.
PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 19-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 20- EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have
authority to resolve problems, take corrective action and, in general, will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI_Utilities 21 -OTHER Applied Notice
RECEIVED
City of Tigard OCT 0 9 2018
PUBLIC WORKS —ENGINEERING
CITY OF TIG
Public FacihtyImprov-eine � ) Perrmt
TYPE OF WORK
DESCRIPTION OF WORK(in the right-of-way) TYPE 1—Franchise Utility Work
Check one: X Utilities ❑ Sidewalk/driveway approach ❑ Street improvements performed by NWN, PGE
Detailed description: Install alum fluted poles and acorn lights and/or utility agency.
❑ TYPE 2—Sidewalk/Driveway/Sewer
Work performed for the purpose of:
• Sidewalk installation or repair.
SW Roy Rogers Rd and SW Scholls Ferry Rd - Driveway approach installation
Property address/location(s): and/or repair
Sherwood,OR 97140 • Sanitary sewer lateral installation
and/or main line tap
Portland General Electric ❑ TYPE 3—Full scale Development
Applicant: Work performed with Land use
Address: 10800 SW AverySt approval which includes any of
City/state: Tualatin,OR Zip. 97062 the following:
Phone: 503-464-7777 Email: preregcoord@pgn.com • Subdivisions or Partitions
Contact name: Rodrigo Solis Phone: 503-672-5417 • Street widening
• Mainline installation for Sanitary
Contractor: United Excavators sewer, Storm sewer, Tigard water
and/or Tigard Water Service Area
CCB#: 198822 Expiration:
Address: 4804 NW Bethany Blvd STE 1-2 PMB 361 SUBMIT COMPLETED APPLICATION TO:
City/state: Portland,OR Zip: 97229 City of Tigard
971 322-7872 unitedexcavators@gmaii.com Planning/Engineering
Phone: ( ) Email: Cg 13125 SW Hall Blvd.
Contact name: Brad Taggart Phone: 503-914-7166 Tigard,OR 97223
Applications for"minor work in right-of-way"
Engineer: NSA only may be emailed to:
g rowpermitsna,tigard-or.gov
Address:
City/state: Zip:
Phone: Email: Case No.: �2,019
Contact name: Application submittal fee(007%of
Engineers Estimate) $
Estimated value of work is required(if over$5,000):$ 58,165.45 Additional fees: 1-Aer
(within the public right-of-way) Application accepted:
LC
Is work related to a LAND-USE DECISION? El Yes No By: Date:
If so,please specify (MLP,SDR,SUB, etc.) case #: Application reviewed:
By: &S _Date: h 2-01
Is work related to a BUILDING PERMIT? ❑ Yes X No Applicant notified:
If so,please specify(BUILDING PERMIT)case#: By: Date: to
I:\ENG\PermitApplications\pfi—application Rev.10/16/2017
City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 1 of4
APPLICANTS
NOTE: Person specified as "Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if
required by the city pursuant to TMC 15.041.140.
* With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different
people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the
owner. The owner(s)must sign this application in the space provided or submit a written authorization with this application. Franchised
Utilities are not required to obtain the owners signature on the application
BY SIGNING BELOW,THE APPLICANTS) SHALL CERTIFY THAT:
• The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject
prope
• If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
• All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and
the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such
statements are false.
• The applicant has read the entire contents of the application,including the policies and criteria,and understands the
requirements for approving or denying the application.
Kevin D Muck 10/09/18
Applicant/Authorized Agent's signature Print name Date
SIGNATURES of each owner of the subject property, if required.
Owner's signature Print name Date
Owner's signature Print name Date
Owner's signature Print name Date
PUBLIC FACILITY IMPROVEMENT PERMIT
City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 • Page 2 of4
DEVELOPMENT ENGINEERING FEES
Public Facility Improvement(PFI)Permit:
DETAILED C
REQUIREMENTS
APPLICATION FEE
Part 1: Required submittal fee$300.00 (minimum) FRANCHISE UTILITY AND SIDEWALK/
DRIVEWAY AND UTILITY
PERMIT FEE CONNECTIONS,ETC.
Part 2: All non-water system improvements (work in the right of way)
Engineer's estimate X 5% (less$300.00 minimum
submittal fee) Sketch
Engineer's estimate X 2%Plan Review (including information below)
❑ Dimensions
WATER SYSTEM FEE ❑ Street Name
Part 3: All public water system improvements ❑ Site Address
Engineer's estimate X 12%
FULL SCALE DEVELOPMENT
PFI Permit Fee Exemptions: (Subdivisions/Partitions and Street Improvements)
There will be no permit fee charged,or assurance required
for the following types of work: Design Plans
• Sidewalk repair(less than 20 lineal feet) (6 sets,24x36 or 22x34)
• Relocate or replace mailbox ❑ Cover—Site,Vicinity,Abbreviation,Legend
• Ditch cleaning that does not involve regrading. ❑ General Notes(City,Water,Sewer,etc.)
• Weep hole repair ❑ Street(Plan,Profile)
• Curb repair or replacement(less than 20 lineal feet) ❑ Water,Storm and Sanitary(Plan Profile)
• Lawn sprinkler system installation or repair ❑ Water Quality Facilities
• Street tree pruning or planting ❑ Grading
• Planter strip landscape maintenance ❑ Landscaping/Tree Plan
• Test wells ❑ Composite Utility Plan(Electrical,Phone,Gas,
Storm,Sanitary,Water,Signage,Street Lights,etc)
❑ Details
Note: A cash/bond assurance maybe ❑ Traffic Sight Distance
required per TMC 15.04.140. ❑ Signing and Striping
(customer deposit) ❑ Street Light Plan and Photometric
❑ Engineers seal/signature
❑ Sheet label(project land use name,revision and
plan log block,dates and sheet numbers.)
Additional Submittals
(per Land Use conditions)
❑ Traffic Report
❑ Storm water Drainage Calculations
❑ Geotechnical Report
❑ Preliminary Access Report(Sight Distance)
❑ Proposed Plat
❑ Pathway Design(if applicable)
❑ Water Department Approval
❑ Engineers Construction Estimate
PUBLIC FACILITY IMPROVEMENT PERMIT
City ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 3 of4
SAMPLE SKETCH:
'sI�v •� _ „
Edge of Pavement
Ditch -�
Streetlight I .—.—.-----.—.—.=I�—E—
I � Roin Drwn
I I
a a-aa �as aaaa I
' T fro os cf�SerwerTne .
I 1 -
I ;� Existing House
Existing
I I ;i Driveway 1
d) I I
CCL
1 .t I •
01
co
> 1
Existing Shop
CA
Powerpole I = I 1
CD O .
-------
�operty7e —-—-—-—-—-
I 'Lin
Fire Hydrant(FH)
I � I
Scale: 'I"=30'
I I
� I .
I I I
' I I
I I
I I I
MINIMUM SKETCH REQUIREMENTS (Put"N/A"if Not Applicable):
North arrow Property lines & dimension Slope of property
Street &street name(s) Existing building, structures Utility&street light poles
Proposed work Existing curb or edge Trees
Existing S/W or of pavement Existing utility locations
D/\X'apron (sewer,water,storm)
PUBLIC FACILITY IMPROVEMENT PERMIT
City ot-Tigard • 13125 SW Hall B1vd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 Page 4 of4
LIGHTING LEGEND
(UNLESS OTHERWISE SPECIFIED) i
OPTION A
INSTALL VW AL-TX ST LT CIRCUIT IN 1-3"SCH40 PVC
------CONDUIT,PROVIDED d INSTALLED BY CUSTOMER
INSTALL HIO CU-TX ST LT CIRCUIT IN I-1'SCFW PVC
Y Rp ----- CONDUIT,PROVIDED U INSTALLED BY CUSTOMER
SCROLLS FERR O cusromEa w6ALLED 1730
ACORN
VAULT
SW INSTALL
ON IWALACK ALUMINUM FLUTED POLE
SET 2'FP-FC,EXCEPT WHERE NOTED,
CD PL-403
CONNECT AT 240V
° P1�02
_— 1200A INSTALL 7OW LED HADCO ACORN LIGHT
5697 VT-394 VF-390 PL-405 -- -- -5'-- - ON 16'BUCK ALUMINUM FLUTED POLE
SET 2'FP-FC,EXCEPT WHERE NOTED,
CONNECT AT 240V
sw -39 94 DO WITH RESDEV WO#2279741
PL-406 - 1
QQ37 Vi 383 45 W I Y I 1 t=J PD 203 NOTE:
Q
00I PGE TO PROVIDE CONCRETE BASES AND GROUND RODS FOR
1 3-7D TRACT B
245 246 247 248 2 I > CUSTOMER TO INSTALL AT THE SAME TIME AS THE CONDUIT.
264
3 TRA VT-400
263 0 Sas PD 382-�Q- 1 PL 41 INSTALL 30AMP FUSES IN SECONDARY PEDESTALS OR SECONDARY
VAULTS(WHICHEVER IS ST LT POINT OF ATTACHMENT)FOR TEACH
262 PD 381 _ STREET LIGHT PERT&D CONSTRUCTION STANDARD LC-11550
26131. 55 PD 205
VT 384 VT 38
260 PL *407 PL-41
4 VT-3
259 11" 193
1 258 257 156 2.151 L254253 252 251 O
I
2 -
ur 377 278 04017 Q 2008 55 yr 380 !`--- --------• ------- --''
277 1201
279
276 -409 45' SW FRIENDLY W
1 PL-408 PL-410 PL-411
� 1
VT 657 120,
-— 270'
275 --VT-407
----------------------------
282 O FV 00051
O 274 ASCABC-7mW EPR JKT-D YT m® SCROLLS FERRY-RAINBOW
280 VT 65627 FEgIY-Ib'y IUMIKL VT 00052
3 200A
28I 272RcM0u CONSTRUCTION NOTES: SLCST
271 Q 1.CUSTOMER TO PROVIDE ALL TRES.JNTNCHING,BACKFILLIWITHNG CONDUIT,ELBOWS.JUNCTION
b INC1ITRENCH
ESS DEEP AND 30 INWIDE,EEASUR NCH D ROOM kINAL GGRRATDE BE
VT 655 h
VT 658 270 W 2.A PGE STANDBY CREW IS REUIIQUIRED FONTIEACR OENINO ALL ENERGIZED POE VAIATS
S l,,l 1-� OFCONDUITSANA PULL STRINGS.CALL SERVICE"CCOORDINATION AT 60p"1323870D�uTM)"
INS
TO SCHEDULE A PGE STANDBY CREW.
PL 6�8 t O 3.ALL PGE CONDUCTORS TO BE INSTALLED M GRAY,SCHEDULE 40,ELECTRICAL
PL-699 G N 09 269 Q GRADE.PVC CONDUIT WITH NYLON PULL STRINGS(MIN.300 LBS.TEST
ZO' PGE TO DETERMINE THE SIZE AND NUMBER OF CONDORS REOURED.
BETWEEN
VT-697 PD 654 2 L GAS AMAINTNDOTHERRU�TILL INCHES ANDLIITES.ALL LBOWS4INCH SONTAL IMALLER O NCH RADIUS.
268 O RICK)1 FEET OR LONGER,OR OR ANY LENGTH RUN WITS BENDS H MORE RE REQUIRED
ISO DEGREES F
IN BENDS.PJC SCHEDULE 40 BENDS ARE ACCEPTABLE FOR RUNS OF 150 FEET OR
LESS.THE MAXIMUM TOTAL BENDS IN ANY CONDUIT RUN IS 270 DEGREES.ALL
BE MUST BE FACTORY MADE,REFER TO LETTER OF RESPONSIBILITY FOR
PD 653 Y I 267 FURTHER DETAILS.
H
4.ALL H CONCRETE CURISIDEWALK FOOTINGS HEED TO BE INSTALLED WITH TOP OF BASE
I 266 FLUSH TO CURB I SIDEWALK
TRACT EE I S.CUSTOMER RESPONSIBLE FOR ROAD CROSSINGS.ALL CROSSINGS MUST EXTEND
( FROM PROPERTY LINE TO PROPERTY ONE.CROSSINGS TO BE 48 INCHES DEEP,
265 MEASURED FROM FINAL GRADE.
e MR CTIONAL OR SCHEDULE 40 BORING
WnITH ARMECHANICAL EMENTS CONNECTPE�HNGHTIVE TO HDPE CERTA-LOK TY POLYETHYLENE)
R LIKE MECHHANICALCONNECTION
.HD ESHALLMEETTHE
VT 659 REQUIREMENTS OFPGE S(PECAS IFICATION"LC205 5.FOR SAFETY REASONS THE DUCT S(AVAILABLEBE WRNE/1�QUEST EOM POELLY SPACEI
HDPE%E ISEREW P E PFT MS ALLAIS A ECIFICATION T N WITH
PPGREEINS ECLTOR PRESENTT. TEST OF
~
T.TRANSFORMER PADS ARE TO BE SET SO THAT THE TOP IS 21NCHES ABOVE
152 FINAL GRADE.CONDUIT IS TO BE INSTALLED IN PAD AS INDICATED IN DETAIL
Z AND TO EXTEND 1 INCH ABOVE THE PAD.
rc TO BE ( 11�8
W
153 8 BUILDING,wu OR OV
E
SR
HA
N
G
D 4AFEET 8 MIroN FMROL ANY FIRE Y HYDRANT.
PGE TRANSFORMERS MUST BE WITHIN 15 FEET Of A DRIVEABLE AREA
ANY DEVIATION FROM THIS DESIGN MUSTALWAYS MAINTAIN 10 FEET CLEARA ICE IN FRONT OF ALL TRANSFORMERS.
N 154 BE APPROVED BY PGE PROJECT MANAGER B.STEELBARRIER POSTS ARE REQUIRED AROUND TRANSFORMERS THAT ARE EXPOSED
48 47 46 45 TO VEHICLES.
155 10.AFNEEE NEEDED-FR
ONT LOT PUBLIC UTILITY EASEMENT(P.U.EJ TO BE 8 FEET(min
PGE FACILITIES NOT DRAWN TO SCALE 11.CONSULT WITH PGE REPRESENTATIVE 2 WEEKS BEFORE STARTING MAIN POWER
TRE156 THIS DRAWING IS A GRAPHfCAL REPRESENTATION OF PORTLAND GENERAL WILL BE EXCANO VATOR�"SMOOO,CTTVTRUCTION G�Ice INCLUDED IN THIS CONFERENCE
PO 357 ELECTRIC FACILITIES IN THE FIELD.THIS MAP ILLUSTRATES ELECTRICAL 12,CUSTOMER TRENCH AND ELBOW CONFIGURATIONS.ALL CONDUIT,VAULT AND PAD
CONNECTMTY,TYPES AND NUMBERS OF CONDUCTORS AND PLACEMENT OF INSTALLATIONS MUST BE INSPECTED BY PGE PRIOR TO BACKFILLING.WHEN YOU ARE
READY FOR PGE TO INSPECT(AFTER INSTALLATION IS COMPLETq,,,CALL 501r�7�36-5650
EQUIPMENT WITHIN THE DISTRIBUTION SYSTEM.R IS RECOMMENDED THAT REFER TO THE ( ECTnIc�Ekvc IS
"boGD°IaA��OR SPEC IC TO OCCUR.REFER TO ME PGE
157 THE USER NOT RELY ON THIS DIAGRAM FOR GEOGRAPHICAL LOCATIONS 13,DESIGN IS BASD ON STANDARD UNDERGROUND E PENT.NONSTANDARD UNDER-
GROUND EOIRPMEN
MAY
AN OPTION AT AN COST TO THE CUSTOMER
JUNCTION BOX INSTALLATIONS eaDHwDRODIHsrALunDM :,AA.T RPL urRnY vuxT wee.-+.eF Rro PGE CONSTRUCTION DRAWING
FOR STREET LIGHTING E--� PRECAST coHaETE Fo0TR+0
CONTACT PGE FOR APPROVEDIMNUFACNE
RERsATA[S7RFETCI[A'/7 PoLf5 1"T-'�sT1�L1 QIHl FoolMc ..- CONTACT SERVICE COORDINATOR DATE:S1R876 SCALE:NTS [ACCOUNT 1070001 AWT:1000004600 OB NO.M2588168
t4sR,Rbm FOR TRENCH AND CONOIRT WSNCTXIN POOR
F` i�'o:F" oAo.wPPoo�.rK,K TO 94WU PGE WKL HOT INSTALL WIRE T�
UNTIL TKFNCH Is XKIL AKATMIED. ` POLYGON NORTHWEST/RIVER TERRACE FAST PHASE 3
F1E1n �,r RI.w Tc°esiaex roiu uu G SERVICE COORDINATOR CIRCUIT SIZE
x � 503-323-6700 OR 800-542-8818(SALEM) SCHOLLS FERRY-ROY ROGERS 17x22
µ.9'^ucRar,Ron.wAIVNAsncvwsrer
M, uuA,E[V DP AA - PGE LOCATION
w F, TT►�77
ATTENTION: CALL 811 BEFORE YOU DIG
A«�Yo nrmla+.FOAm Ausr�w4T.uet-Pw _ --� THINK OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED � �' ` � SW ROY ROGERS RD AND SW SCHOLIS FERRY RD,SHERWOOD
-- auY °Roo 7FraV TmAmrom4Tv:AsrrNrnow BY THE OREGON UTILITY N071FIUTION CENTER.
QI1DESCRIPTION INSTALL 10 AtTXST LT CIRCUTr IN T-3'TO 2-70W LED HADCO ACORN a TI-60W
�yL [wAPE PERAFSCnSCAPPRPNDeYP[NE. p p�/�{{P
R'B i THOSE RULES ARE SET FORTH IN OAR 952-001-0010 LED YARMOUTH ACORN LIGHTS ON 16'KACK ALUM FLUTED POLE£CONNECT®240V
�iFioA Mnlr awl3Pca � THROUGH 952-001-009°.YOU MAY OBTNN COPIES OF
o� THE RULES BY CALLING THE OREGON UTILITY COUNTY E[TION(5) YJORIL WITH SHFFT
i .�.v '"011 A N eoloRrosAccolecaa�Percc.AEcrrm "'-- FIJ a` NOTIFICATION CENTER ADMINISTRATION 0 (503-23 1987) eEAVERtON DESIGN
By ON C2106D I I
Aw toeouclox� �`' IfiREw ewotcra8 �-
ONE CREW CENTER BY PNONE(503) DRAWN RY
TO REQUEST UTILITY LOCATES CALL THE OREGON nu sw Nalm aT
UTILITY NOTIFICATION CENTER BITAT LEAST ��wkDYs bB1Ov+. RICO SOUS 672-5477 CESAR DEL ROSARIO
eFAIRTQV,W 910D/
2 BUSINESS DAYS PRIOR TO EXCAVATION. Call before you dig. 0 PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED