Loading...
Report 237416 Packaged Rooftop Air-Conditioning Units Page 3 of 10 Thybar Corporation has a policy of continuous product improvement SUBMITTAL and reserves the right to change the product design without notice CURB WALL THICKNESS AND RESTRAINT REQUIREMENTS TO BE DETERMINED BY - 82 1/2 O.D. — SEISMIC/WINDLOAD CALCULATIONS. — 15 7/8 29 25 3/4 11 7/8 -� VERIFY ROOF PITCH AND DIRECTION I ' ` ' ` �❑ APPROVED 61/8 0` ' " — f APPROVED I 13 7/8 PENDING CHANGES BY: ` DATE: I / 54 O.D. 48 1/2 ..DATE: J 47 7/8 Clear I.D. 40 1/8 +14.51441.. tut®QC i —' H7 ID , J 44. F- JIMA Mk PLAN VIEW ,� .,w,, 6 5/8 2"x4" pressure treated wood nailer 2 3/8 --- —. F 3 7/8 W00r144vfF / `1 L___ ___ r�� r 1 1 _ _ f xi,rrumasPr.ru�I — __ I asetArna 29 I — — E J s.l 1 I r! , 17 1/4 1 -=AMID 77 1/4 Clear I.D. J - -mm"r-�I I I ELEVATION VIEW TYPICAL SECTION The information contained in this Vibrocurb III Uninsulated 2" Def. drawing is the sole property of - Thybar Corporation.Any New Aaon - RN009 Steam & Hot Water(03578) reproduction in part or whole without the written consent of Jognson Barrow Inc.! CWD Durham WWTP Thybar Corporation is prohibited (DO NOT SCALE DRAWING) Qt 1 Job# :Q-1805096 Unless otherwise specified y" dimensions are in inches Tag:920AHUO3 ® t h ba r. tolerances are Drawn: Rev. Int. Date Description ±1/16 ±0.0625 ±1° CORPORATION REVISION HISTORY SGP Date:6/7/18 File: S200525VC Rev: 'x,ighr 237416 Packaged Rooftop Air-Conditioning Units Page 4 of 10 Thybar Corporation has a policy of continuous product improvement and reserves the right to change the product design without notice SUBMITTAL CURB WALL THICKNESS AND RESTRAINT REQUIREMENTS TO BE 77 1/2 O.D. — DETERMINED BY SEISMIC/WINDLOAD CALCULATIONS. --- 15 5/8 26 - 35 7/8 VERIFY ROOF PITCH AND DIRECTION 4 3/8 -i I I '. — ❑ APPROVED 14ni APPROVED _ I 1 PENDING CHANGES 39 1/4 O.D. 33 3/4 BY: 34 7/8 Clear I.D. 25 1/4 DATE: I / \.--.., 7-, car ra-a, • PLAN VIEW IP - MoaAtoN P s6shnd s ►ea L_ _____ __ 1___^,___J 2"x4" pressure treated wood nailer .N0Oi *f / 29 I I 1 / I ri I 17 1/4 XI sx•estty lark ritAuth toot._ I- 72 Clear I.D. -I GAM ,G" ELEVATION VIEW aito.tn. TYPICAL SECTION The information contained in this Vibrocurb III Uninsulated 2" Def. drawing is the sole property of Thybar Corporation.Any New Aaon - RN008 Pwr Exh (03273) reproduction in part or whole ' without the written consent of Jognson Barrow Inc./ CWD Durham WWTP Thybar Corporation is prohibited (DO NOT SCALE DRAWING) Qt 1 Job# :Q-1805096 Unless otherwise specified y" dimensions are in inches Tag:92OAHU04] • t ba r tolerances are Rev. Int. Date Description ±1/16 ±0.0625 ±1° Drawn: REVISION HISTORY AQP cothe first tne, RaowaTi e Date: File: Rev: ■ .frn►rrt S200526VCever/one 237416 Packaged Rooftop Air-Conditioning Units Page 5 of 10 Thybar Corporation has a policy of continuous product improvement and reserves the right to change the product design without notice - 77 1/2 0.D. — SUBMITTAL CURB WALL THICKNESS AND RESTRAINT REQUIREMENTS TO BE DETERMINED BY F/` 18 3/44SEISMIC/WINDLOAD CALCULATIONS. VERIFY ROOF PITCH AND DIRECTION f 33 3/4 Clear I.D. fpr' r.a.0 r l',:- ..._'+.s +iU 39 1/4 O.D. 34 1/8 25 1/8 ` r IT�`.xt9N 1 \J `J if11.+4 TH[i--.. at d-wtT� xtp&3tRM+G 2"x4" pressure treated wood nailer PLAN VIEW '"r ata Deus- ,,r P1.Avr GA GAIN.Int t -=ARM. M. 1 _ I — 11 D r1 o -w 4 v--el 29 1 I 7 17 1/4 TYPICAL SECTION I 0 APPROVED 72 Clear I.D. -1 r-7❑ PENDING CHANGES ELEVATION VIEW BY: DATE: / / The information contained in this Vibrocurb III Uninsulated 2" Def. drawing is the sole property of Thybar Corporation.Any New Aaon RQ002-006 Power Exhaust (03753) reproduction in part or whole without the written consent of Jognson Barrow Inc./ CWS Durham WWTP Thybar Corporation is prohibited (DO NOT SCALE DRAWING) Qt 1 Job# :1805096 Unless otherwise specified y" dimensions are in inches Tag `920ALIU05'', 111 t hyba r tolerances are Drawn. t 1/16 t 0.0625 t 1° AGP CORPORA-110'4 File: Rev: ' ■ rt>ybarmakes nNghrthe ilstarre Date:6/7/18 S200527VC ---- even,One 237416 Packaged Rooftop Air-Conditioning Units Page 6 of 10 Thybar Corporation has a policy of continuous product improvement SUBMITTAL and reserves the right to change the product design without notice CURB WALL THICKNESS AND RESTRAINT REQUIREMENTS TO BE DETERMINED BY SEISMIC/WINDLOAD CALCULATIONS. VERIFY ROOF PITCH AND DIRECTION 791/2 I.D. 14 3/8 25 3/4 - 10 3/8 4 5/8 APPROVED APPROVED 1-1 PENDING CHANGES BY: DATE: I / 51 I.D. 46 3/8 38 5/8 1 _ � 1"x4" pressure treated nailer PLAN VIEW 1 1'2 in GASKET WOOD NAILER �I L 1 1 If LJ" OPTIONAL LINER 19 RI DENSITY HEIGHT 'I RIGID INSULATION HEAVY GA. GALE". STEEL ELEVATION VIEW 2 in TC-3 SECTION The information contained in this Non-Insulated Roof Curb drawing is the sole property of Thybar Corporation.Any New Aaon - RN009 Steam & Hot Water(03578) reproduction in part or whole without the written consent of Jognson Barrow Inc./CWS Durham WWTP Thybar Corporation is prohibited (DO NOT SCALE DRAWING) Qt 1 Job# :Q-1805096 Unless otherwise specified y" dimensions are in inches Ta992OAHU061 r t hyba r tolerances are Rev. Int. Date Description ±1/16 ±0.0625 f1° Drawn: -- REVISION HISTORY SGP caaaoRnnok Date:6/7/18 File: S200528RC Rev: ■ +ybarsmokes xtipbt 237416 Packaged Rooftop Air-Conditioning Units Page 7 of 10 Thybar Corporation has a policy of continuous product improvement and reserves the right to change the product design without notice SUBMITTAL CURB WALL THICKNESS AND RESTRAINT REQUIREMENTS TO BE DETERMINED BY SEISMIC/WINDLOAD CALCULATIONS. VERIFY ROOF PITCH AND DIRECTION 79 1/2 I.D. 414 3/8 29 25 3/4 10 3/8 4 5/8 APPROVED APPROVED ❑ PENDING CHANGES BY: 51 I.D. DATE: / I 46 3/8 38 5/8 1 1 1 1"x4" pressure treated nailer PLAN VIEW 112in GASKET LIT WOOD NAILER I, L 1 L J'F 18 OPTIONAL LINER 3x DENSITY HEIGHT RIGID INSULATION h. HEAVY GA. GALV. STEEL ELEVATION VIEW 2 In TC-3 SECTION The information contained in this Non-Insulated Roof Curb drawing is the sole property of Thybar Corporation.Any New Aaon - RN009 Steam & Hot Water(03578) reproduction in part or whole without the written consent of Jonson Barrow Inc.! CWS Durham WWTP Thybar Corporation is prohibited (DO NOT SCALE DRAWING) Qty.: 1 Job# :Q-1805096 Unless otherwise specified dimensions are in inches Tag:920AHU07 ■ t b'a r tolerances are Drawn: Rev. Int. Date Description ±1/16 ±0.0625 ±1° AGP REVISION HISTORY Date:6/7/18 File: S200529RC Rev: ■ Thybar makes+tevery ttne ' ' 237416 Packaged Rooftop Air-Conditioning Units Page 8 of 10 Thybar Corporation has a policy of continuous product improvement SUBMITTAL and reserves the right to change the product design without notice CURB WALL THICKNESS AND RESTRAINT REQUIREMENTS TO BE DETERMINED BY SEISMIC/WINDLOAD CALCULATIONS. VERIFY ROOF PITCH AND DIRECTION — 1081/21.D. — 33 7/8 10 3/8 37 5/8 - - 18 3/4 - 7 7/8 iE APPROVED 2 1/8 i ni APPROVED 1 PENDING CHANGES 11 1/8 BY: ` DATE: J 36 1/4 I.D. 3411/8 \ 1 25 1/8 1 PLAN VIEW 1"x4" pressure treated nailer 1 1 27 ' -r r 1 r GASKET 19 11 Ill ''WOOD NAILER L111 OPTIONAL LINER 3It DENSITY ELEVATION VIEWHEIGHT RIGID INSULATION t.._ HEAVY GA. GALV. STEEL 2 in TC-3 SECTION The information contained in this Non-Insulated Roof Curb drawing is the sole property of Thybar Corporation.Any New Aaon - RN009 Steam & Hot Water (03754) reproduction in part or whole without the written consent of Jognson Barrow Inc./CWS Durham WWTP Thybar Corporation is prohibited (DO NOT SCALE DRAWING) Qty.: 1 Job# :Q-1805096 Unless otherwise specified dimensions are in inches Tag:920AHU08 • thybar tolerances are Drawn: Rev. Int. Date Description ±1/16 ±0.0625 f 1° AGP CORPORATION MON-makes It right**OW tinV4 REVISION HISTORY Date:6/6/18 File: Rev: S200530RC !My ii71111 237416 Packaged Rooftop Air-Conditioning Units Page 9 of 10 Thybar Corporation has a policy of continuous product improvement and reserves the right to change the product design without notice SUBMITTAL CURB WALL THICKNESS AND RESTRAINT REQUIREMENTS TO BE DETERMINED BY SEISMIC/WINDLOAD CALCULATIONS. 101 3/8 I.D. — VERIFY ROOF PITCH AND DIRECTION 22 1/2 31 1/8 — 34 1/2 13 1/4 --- ❑ APPROVED 9 3/8 APPROVED ❑ PENDING CHANGES BY: DATE: / I 51 I.D. 41 5/8 PLAN VIEW 1"x4" pressure treated nailer /112in 2 3/8 --- 6 GASKET I� � WOOD NAILER L J L1 r �I I I 19 3 5/8 OPTIONAL LINER 3# DENSITY HEIGHT I RIGID INSULATION ELEVATION VIEW I HEAVY GA. GALV. STEEL 2 in TC-3 SECTION The information contained in this Non-Insulated Roof Curb drawing is the sole property of Thybar Corporation.Any New Aaon - RN009 Steam & Hot Water(03579) reproduction in part or whole without the written consent of Jognson Barrow Inc./CWS Durham WWTP Thybar Corporation is prohibited (DO NOT SCALE DRAWING) Qty.: 1 Job# :0-1805096 Unless otherwise specified 1111 dimensions are in inches Tag:r920A1-IU09J t h (ba r tolerances are Drawn: Rev. Int. Date Description f 1/16 10.0625 t 1° AGP CORPORATION REVISION HISTORY Date:6/6/18 title: Rev: ■ +,yt,ar:r ra�tdpht the first tam, 5200531 RCenvy Me 237416 Packaged Rooftop Air-Conditioning Units Page 10 of 10 Thybar Corporation has a policy of continuous product improvement and reserves the right to change the product design without notice SUBMITTAL CURB WALL THICKNESS AND RESTRAINT REQUIREMENTS TO BE DETERMINED BY SEISMIC/WINDLOAD CALCULATIONS. VERIFY ROOF PITCH AND DIRECTION 170 3/8 I.D. APPROVED APPROVED PENDING CHANGES BY: DATE: I I 51 I.D. PLAN VIEW END VIEW 1"x4" pressure treated nailer ir2in GASKET Il WOOD NAILER 14 I 11 9I il I OPTIONAL LINER 3s; DENSITY ELEVATION VIEW HEIGHT RIGID INSULATION HEAt,'Y GA. GALV. STEEL _l___. 2 in TC-3 SECTION The information contained in this I TC-5 Non-Insulated Roof Curb drawing is the sole property of . Thybar Corporation.Any New Aaon RNA "C" Cabinet - Horizontal Unit, Air Cooled Empty H1l reproduction in part or whole Equipment Base without the written consent of Johnson Barrow, Inc. / CWS Durham WWTP Q • Thybar Corporation is prohibited N (DO NOT SCALE DRAWING) Unless otherwise specified Ta ' �920AHY Job# :Q-1805096 ai U1Q dimensions are in inches II t h ba r oo tolerances are ---- ----- Rev. Int. Date Description ±1/16 +0.0625 ±1° Drawn: CORPORATION REVISION HISTORY File: Rev: ■ makes aright the first time, �, Date:4/6/18 S 199651 RC ---- 1 -- e'"'time