Loading...
Specifications (28) Gtit' "1 - :. Lv is Client F ? S Sheet I of r , '-') I 1°(:)%(S U ,- Project D'c - MEG AM. (2-C CA ati\-% uesicn ty 0,A S r ,; Date 1419 Washington Street,Suite 100 Checked by Oregon City,OR 97045 Project No. 13— CM Doie Work:503-657-9800 Fax:503-656-0186 —— — -V01\X(Z S 1(ZWSC2 g 11—'3'r SQ�n/ S c c2, L- D O : 3�% = 1.7gTaie 000 i_ \71.4 �. s��or1: 2'ii c.��G. 1so2c�x(2'�� _ .� k A l2� ( 1.�.s��l= 5G j� 141-1)" / ---�. — r276.6 - IV— `)QL s6 ' C 4'3'`) 3q4 2 ,'. v se.- 31/i x \-)7/a.. c)‘-c-3 (:: page Project: 17-069 Oak Tree Apts. Repairs _ _ _ _ Dustin Selby Location:Stair Stringer 1 StruCalc Version 10-.0." 4: 5/10/20'8 5:22:04 PM Multi-Loaded Multi-Span Beam of [2015 International Building Code(2015 NDS)] 3.5 IN x 13.5 IN x 14.25 FT (Actual 17 FT) 124F-V4-Visually Graded Western Species-Wet Use -iSection Adequate By: 157.8% lControlling Factor:Deflection DEFLECTIONS Center LOADING DIAGRAM Live Load 0.22 IN L/928 Dead Load 0.10 in Total Load 0.32 IN L/644 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria:L/240 REACTIONS A Live Load 1277 lb 1277 lb Dead Load 563 lb 563 lb Total Load 1840 lb 1840 lb Bearing Length 1.53 in 1.53 in BEAM DATA Center _ w - -- — �y Span Length 14.25 ft ` ft 14.25 • Unbraced Length-Top 1 ft A Unbraced Length-Bottom 14.25 ft Beam End Elevation Difference 9.26 ft Live Load Duration Factor 1.00 UNIFORM LOADS Center Camber Adj.Factor 0 Uniform Live Load 179 plf Camber Required 0 Notch Depth 0.00 Uniform Dead Load 56 plf Beam Self Weight 10 plf MATERIAL PROPERTIES Total Uniform Load 245 plf 24F-V4-Visually Graded Western Species Base Values Adjusted Bending Stress: Fb= 2400 psi Controlled by: Fb_cmpr= 1850 psi Fb'= 1913 psi Cm=0.80 C1=1.00 Shear Stress: Fv= 265 psi Fv'= 232 psi Cd=1.00 Cm=0.88 Modulus of Elasticity: E= 1800 ksi E'= 1499 ksi Cm=0.83 Comp. to Grain: Fc- = 650 psi Fc- '= 345 psi Cm=0.53 Controlling Moment: 6554 ft-lb 7.127 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: -1543 lb 14.255 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Comparisons with required sections: Rea'd Provided Section Modulus: 41.1 in3 106.31 in3 Area(Shear): 9.98 int 47.25 in2 Moment of Inertia(deflection): 278.35 in4 717.61 in4 Moment: 6554 ft-lb 16951 ft-lb Shear: -1543 lb 7304 lb NOTES Client ---7/ PR Sheet 6:1?-. of • c444:‘:„1 --r AN — - - — Project 0 - Desig A-) 2 Date '4'4-,•,fiLNEERO:'- ' 1419 Washington Street,Suite 100Checked byOregon City,OR 97045 Project No. 1 Dcte Work:503-657-9800 Fax:503-656-0186 rfl- ?(A rir101v Itg Frr stj C ¶4 i1L4 4iirPrINJ 6 P'-1 511R1—"erNiDits-10 `Two 1,11,ras2, crs (.1 eIIY 067q4a,C \.nr 1 Pru. 1, YJ sreS vi 1> f) C.• "ro P ra,0 DE:4k.re0 C -rR‘A PI 6-1t 41A-1 tz, 0 0 P5 f‘,01 AN Nc,a ,t0314 .4:**T , 1 858,:: A R/G4614 10• (1,- 5 Al/VD XPRES: C, 20 10 r IS • 4