Loading...
Plans CrrY OP TIGARD SCOPE OF WO. ,< REVIEWED FOR CODE COMPLIANCE 1) The area of work shown is to have fire sprinkler drops installed in a - Approvedt��] ' I V .. new cooler (cooler by others). Changes to the sprinkler system OTC: t 1 designed, fabricated and installed in accordance with NFPA 13 2013 and l SEP 1 g Zplg local standards. Pcrnllt #: �P5��11 g' ) j' CITY Q F. -I � � 2) This contract is limited to area of work shown. Address: 1677 0 S y 7 2 h of A J BUILDING UIVISIQIV Suite #: ‘ GE\ERAL NOTES By: Date: )�.o 1.1 1) All materials devices and hangers used on this project shall be UL Listed and/or FM Approved for use in fire protection systems. FFICE COPY' 2) See attached 'Equipment Data Submittal' for all applicable materials and equipment used in this project. -1 3) All new piping to be 1"black steel, Eddythread40 (or equivalent, .I with threaded ductile iron fittings. '1 5, 4) Any and all painting or paint preparation of piping to be by others. 5) Pipe hangers to be installed in accordance with NFPA 13 2013 and ,, per local AHJ. -I O 1 0 O f) 6) Sprinklers to be installed in accordance with NFPA 13 2013 and per the local AHJ. I I L I I I 1 7) If field conditions result in a change to the shop drawing installation in any way, contact the project engineer to verify proposed changes are compliant with NFPA 13 requirements and per hydraulic design. s 8) This print or drawing shall be used only with reference to contracts G T G T G T (;. G T {; T T TI' of proposals of Wyatt Fire Protection, Inc. This print or drawing shall not be copied for, reproduced for nor exhibited to outside parties. This I print or drawing and any and all copies therefore shall be returned to Wyatt Fire Protection, Inc. upon request. Nothing disclosed herein not publicly available shall be used without written permission from Wyatt Fire Protection, Inc. [ I I C I I II. • E < O \,,,,,.,.„..\,....,,. ., 'Il HANGER KEY l' , 1 Trimline Adjustable Band Hangar _2('-'-' 2 3e" Threaded Rod I, 1111 3 Sidewinder for Wood II •� --T-- . — — — a e • •� 0 4 Wood Structural Member PLEASE PROVIDE COMPLETED NFPA 13 "r.,r MATERIAL AND TEST CERTIFICATE AT COOLED DEFLECTED CE LI \G PLA\ HA\ GES DETAIL FINAL INSPECTION 1/4"=1'-0" NOT TO SCALE Nommiiimmi 0' 2' 4' 8' NOTES REVISIONS SPRINKLER SYMBOLS DATE DESCRIPTION BY SYMBOL STATUS,BRAND SIN TYPE FINISH TEMP(F)ORIFICE THREAD(-FACTOR QTY.NOTES FR 1 .0 NEW TYCO TY3235 SSP-CR Ch/Ch 155 1/2' 1- 5.6 8 DRY,401 ESC. CEDARS M E D I TE R R A N E A N W YAT T PERMIT CO. CONTRACT NO. C18-389 16770 SW 72ND AVE DRAWN BY A.NISHIHARA FIRE PROTECTION, INC. 9095 S.W. Burnham TI G A R D, OREGON 97224 SCALE 14 SEPTEMBER'2018 Tigard,OR 97223 REVISED (503)684-2928 1 of 12 POLAR REFRIDGERATION; P.O.BOX 821127 VANCOUVER,WA 98682