Loading...
PFI2018-00263 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12018-00263 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 09/26/2018 Parcel: SEG1331 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Project Description: SEG 1331. Adjacent to 7380 SW Varns St. Replace poles PL-4182, PL-4181, and PL-4180. PGE Job M2512806. Owner: FEES Description Date Amount PHONE: Contractor: PORTLAND GENERAL ELECTRIC CO 121 SW SALMON ST C/O LEGAL DEPT PORTLAND, OR 97204 PHONE: 503-464-8852 FAX: Applicant: JOHN GUERRY 10800 SW AVERY STREET TUALATIN, OR 97062 PHONE: 503-464-7777 Total $0.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. PermSignature: S�� ASignature: ref}`r Issued By: Lii��i �& Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12018-00263 Type: Condition Name: Status: Severity: PFI Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced, with like kind of material. Obtain City approval of restoration work. PFI Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition, American Traffic Safety Services Association [ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time, without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire& Rescue) and to 503-962-8140(Tri-Met) and 503-431-2345 (Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m. to 7.00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI Utilities 12-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 13- UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work. Applicant shall coordinate the work with affected utility agencies. PFI Utilities 14-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 15- REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches, etc.) as may be necessary, as determined by the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 16- PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>, to establish a preconstruction meeting. PFI—Utilities 17- NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI—Utilities 18- PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 19-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI—Utilities 20- EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing, the names and 24 hour emergency telephone number of two(2) persons who have authority to resolve problems, take corrective action and, in general, will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI—Utilities 21 -OTHER Applied Notice 92rCITY OF TIGARD FEE AND PAYMENT HISTORY , 13125 SW Hall Blvd.,Tigard OR 97223503.639.4171 PF12018-00263 - PGE Revenue Payment Fee Description Account Number Fee Amount Invoiced Paid Date Paid Method Receipt# Due PFI Permit Fee 100-0000-43114 $300.00 $300.00 $300.00 9/27/2018 Credit Card 419668 $0.00 Totals for Fees $300.00 $300.00 $300.00 $0.00 Receipt# Payment Method Check# Payor: Receipt Date Receipt Amount 419668 Credit Card Amy Sweany 09/27/2018 $300.00 Total Payments: $300.00 Balance Due: $0.00 RECEIVED City of Tigard SEP 2 6 2018 PUBLIC WORKS — ENGINEERING CITY OF`t iGARD PLAN NII4G/_ENGlNEERING Public FacilityImprovement (PFI) Permit TYPE OF WORK DESCRIPTION OF WORK{in the right-of--way) V �7 'TYPE 1—Franchise Utility Work Check one: V Utilities Sidewalk/driveway approach ❑ Street improvements performed by NWN, PGE Detailed description: Replace poles PL-4182,PL-4181 & PL-4180 and/or utility agency. ❑ TYPE 2—Sidewalk/Driveway/Sewer Work performed for the purpose of. PGE Job M2512806 • Sidewalk installation or repair. • Driveway approach installation 7380 SW Varns St Property address/location(s): and/or repair 3 Tigard, OR 97223 • Sanitary sewer lateral installation and/or main line tap Applicant: Portland General Electric [I TYPE 3—Full scale Development pp Work performed with Land use Address: 10800 SW Avery St approval which includes any of City/state: Tualatin, OR Zip: 97062 the following: Phone: 503-464-7777 Email: preregcoord@pgn.com • Subdivisions or Partitions Contact name: John Guerry Phone: 503-844-5411 • Street widening • Mainline installation for Sanitary Portland General Electric sewer, Storm sewer, Tigard water Contractor: and/or Tigard Water Service Area CCB#: 103663 Expiration: Address: SUBMIT COMPLETED APPLICATION TO: City/state: Zip: City of Tigard Planning/Engineering Phone: Email: 13125 SW Hall Blvd. Contact name: Phone: Tigard,OR 97223 ,Applications for"minor work in right-of-way" only may be emailed to: Engineer: NSA rowpermitsC;tigard-or.gov Address: OR STAFF USE ONLY City/state: Zip: Phone: Email: Case No.: F12,0k��00aW3 Contact name: .-application submittal fee(007°'0 of Engineer's Estimate) $ Estimated value of work is required(if over$5,000):$ 9,872.53 :additional fees: $ 5r: 4 (within the public right-of-way) Application accepted: jjIs work related to a LAND-USE DECISION? ❑ Yes No By: Date: 21P r d If so,please specify (MLP,SDR,SUB, etc.) case #: application reviewed:&a By � Date: / ' Is work related to a BUILDING PERMIT? ❑ Yes No Applicanotified: Q f If so,please specify(BUILDING PERMIT)case#: By: I Date: I:\ENG\PermitApplications\pfi—application Rev.10/16/2017 CityofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • ,vwwtigard-or.gov • 503-718-2421 • Page 1 of4 APPLICANTS NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work, if required by the city pursuant to TMC 15.041.140. * With the exception of a utility operating pursuant to a valid franchise with the City of"Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided or submit a written authorization with this application. Franchised Utilities are not required to obtain the owner's signature on the application BY SIGNING BELOW,THE APPLICANTS) SHALL CERTIFY THAT: • The above request does not violate ani,recorded deed restrictions that may be attached to or imposed upon the subject proper • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and sub)ect to all the conditions and limitations of the approval. • All of the above statements and the statements in any,plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. Vi n h D Nguyen, Digitally signed by Vinh D Nguyen,PE PE Date:2018.09.25 16:35:19-0700' Applicant/Authorized Agent's signature Print name Date SIGNATURES of each owner of the subject property, if required. Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov 503-718-2421 • Page 2 of4 DEVELOPMENT ENGINEERING FEES FOR STAFF USE ONLY Public Facility Improvement(PFI)Permit: DETAILED SUBMITTAL REQUIREMENTS APPLICATION FEE Part 1: Required submittal fee$300.00 (minimum) FRANCHISE UTILITY AND SIDEWALK/ DRIVEWAY AND UTILITY PERMIT FEE CONNECTIONS,ETC. Part 2: All non-water system improvements (work in the right of way) Engineer's estimate X 5% (less$300.00 minimum submittal fee) Sketch Engineer's estimate X 2°%Plan Review (including information below) ❑ Dimensions WATER SYSTEM FEE ❑ Street Name Part 3: All public water system improvements ❑ Site Address Engineer's estimate X 12°o FULL SCALE DEVELOPMENT PFI Permit Fee Exemptions: (Subdivisions/Partitions and Street Improvements) There will be no permit fee charged,or assurance required for the following types of work: Design Plans • Sidewalk repair(less than 20 lineal feet) (6 sets,24x36 or 22x34) • Relocate or replace mailbox ❑ Cover—Site,Vicinity,Abbreviation,Legend • Ditch cleaning that does not involve regrading. ❑ General Notes(City,Water,Sewer,etc.) • Weep hole repair ❑ Street(Plan,Profile) • Curb repair or replacement(less than 20 lineal feet) ❑ Water,Storm and Sanitary(Plan Profile) • Lawn sprinkler system installation or repair ❑ Water(duality Facilities • Street tree pruning or planting ❑ Grading • Planter strip landscape maintenance ❑ Landscaping/Tree Plan • Test wells ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm,Sanitary,Water,Signage,Street Lights,etc) ❑ Details Note. A cash/bond assurance maybe ❑ Traffic Sight Distance required per TMC 15.04.140. ❑ Signing and Striping (customer deposit) ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) Additional Submittals (per Land Use conditions) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design(if applicable) ❑ Water Department Approval ❑ Engineer's Construction Estimate PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 Page 3 of SAMPLE SKETCH: SWr ,_ t Edge of F a-vemerit p p I -d*- Ditch �'`` Streetlight I ■-■!■!■-■!■ ■!■!� ■! + Resat Drain I I T— ro'p'os cf`Sel+w'e[filne� 1 I Q) I1 A4 Existing House , IN I Existing 1 >I Driveway 01 CU ai V 1 0� CLv I I �I Existing Shop ICA � •� r Powerpole I a ~ � a I �11- 95" I -------_ 7 ---------- �opert�}Lens I I Fire Hydrant(FH) I I � � Scale: 'I"=30' � I I i � I I r ' I � I I MINIMUM SKETCH REQUIREMENTS (Put"N/A" if Not Applicable): North arrow Property lines &dimension Slope of property Street &street name(s) Existing building, structures Utility&street light poles Proposed work Existing curb or edge Trees Existing S/W or of pavement Existing utility locations D/W apron (sewer,water,storm) PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. ■ Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 4 of www.invarion.com Lane Closure at fritersettion with Fiaggin r Diagram 628 ROAD WORK AHEA ONE LANE C I T (Optlon3l) ROAD AHEAD B BE PREPARED TO STOP • B A (Optional) • 0 ONE LANE ROAD 0 9E AHEAD ROAD 100 fl.Max. O PREPARED WORK TO STOP AHEA O A B B C O 4- 0000 O K K O icon Max. } C B B A II ROAD ° %WRXBE 4 PREPARED ° 100 ft.Max. AHEA TO STOP • O ONE LANE ROAD 0 AHEAD It (Optional) A • B BE PREPARED TO STOP B (Optional) ONE LANE 1 tRAD AHEAD C ROAD WORK AHEA .ane Closure at Intersection with'f=lagging Diagram 620 www.invarion.corn Diagram 620 covers work within an intersection when normal traffic control must be interrupted. Work vehicles may or may not be in the work space_ 1. During flagging, traffic signals shall be turned off. Contact the road jurisdiction for approval and assistance (see Chapter 3). 2. For multi-lane facilities, traffic approaching the intersection shall be reduced to a single lane on each approach. See Chapter 3 for information on flagging through intersections. 3. There should be one flagger for each approach. One flagger may control two adjacent approaches if sight distance, low volumes on side roads, and flagger position allows for safe operation and clear direction to motorists. For low traffic volume intersections (fewer than 400 entering vehicles per day), one flagger may be used_ 4. The "ONE LANE ROAD AHEAD" (W20-4)sign is optional and should be considered on high volume or high speed roads, or when extended queues may be expected. Sign Spacing and Buffer Lengths(feet) osted Spacing BethwV#6nSigns Buffer Speed A _ B C Space ERRATA: 20 50 25 100 100 100 75 Supplement Table 30 100 35 350 350 350 125 Updated:February 12, 40 150 2016 45 180 By:ODOT Traffic-Raodway 50 500 500 500 210 section 55 250 Signs Spacing and Buffer Lengths (feet) Supplement Posted sopor; ,between Signs "Buffer" Speed A_- B Spate 60 285 65 700 700 700 325 70 365 r-•--------------------------------------^----------------- eiii --.—.—.—.- cnl�., CL �, ; Single Flagger Operation - for Low Volumes (Optional) �, .. (ADT<400) retror �. I B E m I F nccEa A e a c PREPARED ONE LANE s+ 1 ROAD !� CS 01 00 I 4— t mile ` 7 TO STOP AHEAD .� I m,� t tD a �► ®�°°° ,.* i ROAD 0 _. 'r; WORK B A 1 AHEAPi,liii Vi to vfrTAA{bole DpV°.i ee 8—Cb.Fle,4 rnea"Rm<'> All C We"A B B C �--_-------------------------------------- -----------....... It ...... TIE 1 mile Ito max. �• 0 0 0 0 0--=0 o to o' 000 ® 00 0 0 �► C B BA Buffer Protection Vehicle wfTMA(both Optional) ROAD See Chapter 4 WORK AHEA fit ONE LANE BE ROAD PREPARED Two Flagger Operation o AHEAD TO STOP (Optional) i o' O 3 www.invarion.com Stationary Lane Closure with Flagging -. - Diagram 3 Diagram 320 covers total closure of one lane of a two-lane, two-way roadway. See the detail inset for the layout if using a single flagger to control both directions of traffic on low volume roads (less than 400 ADT)with good sight distance as discussed below. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3—Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Flaggers at each approach are required if any of the following conditions exist: a. Night Operations. b. Work space is over 200 feet in length. c. Sight distance is less than 750 feet from each approach through the lane closure. d.Traffic volumes are greater than 400 ADT. 4.The length between the Flagger Ahead signs shall not exceed one mile. Use Diagram 340—Lane Closure with Pilot Car if exceeding one mile. 5. Cones should be used to outline the work space when curves or other roadway alignments prevent clear direction for the motorists to pass the work space safely. 6. Cones along the work space are recommended when posted speeds are 45 mph or greater, when working under heavy traffic or when travel lanes are narrower than 11 feet. 7. Extended queue signing (see Diagram 5-4)should be used when traffic queues extend beyond the initial advance warning sign. 8. When flagging near an intersection, the "Flagger Ahead" (CW23-2) sign should be visible to traffic entering from any side road.Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). 9. Sign set-up and flagger placement shown may be used for intermittent full road closures of 20 minutes or less. 10. The "ONE LANE ROAD AHEAD" (W20-4)sign is optional and should be considered on high volume or high speed roads, or when extended queues are expected. WL 3 PL-4182: 4530 WL 2 PL-4181: 7360 WL 1 PL-4180:PGE OWNED OVERHEAD LEGEND Install: FTR OWNED POLE 40'-4 1 Install: FTR OWNED POLE Install: POLE kx, V &6, 1961 1 PL 45'—3 PL 45 —3 Sw 1 WORK LOCATIONS 45' 3 1 V EAST 1'WEST KER RD REMOVE/ABANDON FACILITIES_INSTALL FACILITIES 1'EASTT D8 EAST D1 754 50p 1 D1 INSTALL ADDITIONAL FACILITIES/MODIFYFACIL/T/ES 1 P 7.2 120/240 25KVA NT CB 1 1 P 7.2 120/240 OH 50KVA NT1 CB D106 NORTHEAST Al B 110AL TX - - - - - - - . SURVEY GRID BOUNDARY 3 ACCOUNTS ; 11 ACCOUNTS Al -L 17'-22,522#-EAST 5412 J POLES 14.81 KW 19.06KW 7340 G16-PRI-5,687# 45-3 U 1Transfer: G16-NEUT-8,423# 1993 Transfer: �;� �-POLE CLASS (1, 2, 3, 4, H1, H2, S) 1 STREETLIGHT 1STREETLIGHT Transfer: STREETLIGHT USS HT-CL Remove: Remove: ¢.Z PL 40'-4 PL 40'-4 Remove: D1 I D1 PL 40'-4 7300 l POLE HEIGHT 1 1 P 7.2 120/240 OH 37.5KVA NT1 CB D8 X FRAMING TRANSMISSION&DISTRIBUTION(SEE CODES BELOW) TEMP TRANSFER COMMIS), V.D. = 0.74% � � PGE PULLED FLCKR - 0.38% 1 ❑PGE PULLED Al TEMP TRANSFER COMM(S). D106 75.00o !, FRAME DISTRIBUTION-LC10710,MU 0001 TOPPED TO COMM(S) 1 TELCO TO PULL I TOPPED TO COMM(S) N (1 PH TANG,PIN) 7575 7525 1 E]TEL CO TO PULL (2)G16 m FRAME DISTRIBUTION-LC10710,MU 0008 7475 7375 L -TEMP TRANSFER COMM(S), 1098 (1 PH SGL DE, POLY) c0 W 4183 I PGE PULLED FRAME DISTRIBUTION-LC10732,MU 0106 40'-4 I 4182 ❑TOPPED TO COMM(S) 50'-2 W (1 PH SLACK SPAN SGL DE, POLY) TELCO TO PULL 1982 S Q 1959 265' 1 None 3 45$3 7325 7275 418 1 100 T Q ANCHORS � z GUYING = _ _ _ 0 � d BN 2 ACSR gp 250 1959 2 230' a5'-3 = _ z w 0_ 0 o o d C, o Q) N �o �o 2-B_2/0_A[7-SPU N B 2 ACSR None J J d ~ cY3 r3 1 SW VARNS T (LEAD) C? � g POS.-LBS. W QIQ B 25 50B 37.5 2769 1 7 A_ (LBS) U) a "' � 101- 7 1 GUY Q OIO G1 G4 G7 G1 G1 G1 co _ 1 4y o � o N 2 GUYS G2 G5 G8 G11 G1 ~ N!N z m� Anchor Codeco Al A3 A5 A7 A8 3 GUYS G3 G6 G9 G1 G1 G21 G2 Lno,Lr 1 35 7530 V.D. = 0.66%1 rn 1 7430 7380 (' FLCKR 1.61% C)7P 7480 7330 13235 7155 X N I ? 1099 8 38 v 1 50'-2 45 0 1982 19 m � } 1 1 75 vN f 13280 1 3- 1431 m i B 2$j*Y NS S T : 4 8 I 13309 x 0'-4 tj ENTS IJHAMPTON RIDGE APARTMoO 1959 200 Feet co 703013 15 S25 38 320 CID N THINK PGE CONSTRUCTION DRAWING SAFETY AS-BUILT VERIFICATION&NESC VIOLATIONS CORRECTED This document accurately represents FIELD Construction FIRST Foreman: Date: General Foreman: Date.- (Signature ate:(Signature only required for field construction changes.) SDPM/ENG REVIEW.' ASBUILT BY DESIGNER: ANY DEVIATION FROM THIS DESIGN MUST DATE ALE: A UNT AWO: __ JOB NO. 9/13/2018 1 in = 90 ft 1 1070001 0000017443 1 M2512806 BE APPROVED BY THE PGE PROJECT MANAGER TITLE 2016 OH FITNES-REPLACE B/O POLES CALL 811 BEFORE YOU DIGCIRCUIT SIZE ATTENTION: NIINWEST PORTLAND-72ND 111x17 OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED , /PG!/ LOCATION BY THE OREGON UTILITY NOTIFICATION CENTER. 7380 SW VARNS ST,TIGARD, OR, 97223 THOSE RULES ARE SET FORTH IN OAR 952-001-0010 r DESCRIPTION THROUGH 952-001-0090 YOU MAY OBTAIN COPIES OF REPLACE B/O POLES PL-4180, PL-4181, & PL-4182 SHEET THE RULES BY CALLING THE OREGON UTILITY COUNTY SECTIONS WORK WITH NOTIFICATION CENTER ADMINISTRATION @ (502-232-1987) WASHINGTON C2101 D, C2101 C 1 OF 1 TO REQUEST UTILITY LOCATES CALL THE OREGON Know what%below. WILSONVILLE DESIGN BY PHONE DRAWN BY UTILITY NOTIFICATION CENTER, 811 AT LEAST Call before you dig. LINECREWCENTER JOHN GUERRY 503-310-2885 CHRISTIAN S-C 9480 SW 2 BUSINESS DAYS PRIOR TO EXCAVATION W1LONVfLLE OR 9780ECOR 9707 70 O PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED