Loading...
PFI2018-00247 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12018-00247 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 09/19/2018 Parcel: SEG2400 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Project Description: SEG 2400.Adjacent to 9000 SW Durham Road. Install underground service to Tigard High School. PGE Job. M2480441. Owner: FEES Description Date Amount PHONE: Contractor: PRAIRIE ELECTRIC INC 6000 NE 88TH ST VANCOUVER, WA 98665 PHONE: 360-573-2750 FAX: 503-576-7422 Applicant: JAMES CHRISMAN 10800 SW AVERY STREET TUALATIN, OR 97062 PHONE: 503-464-7777 Total $0.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: See application Issued By: -y— � Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12018-00247 Type: Condition Name: Status: Severity: PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time, without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 14-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>, to establish a preconstruction meeting. PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI—Utilities 18-PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 19-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 21 -OTHER Applied Notice PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. RECEIVED SEP 17 2018 City of Tigard CITY OV--TIGARD PUBLIC WORKS —ENGINEERING PLANt tl�Sia'ENGINEERING Public FacilityImprovement (PFI) Permit TYPE OF WORK DESCRIPTION OF WORK(in the right-of-way) TYPE 1—Franchise Utility Work Check one: iZ Utilities ❑ Sidewalk/driveway approach ❑Street improvements performed by NWN, PGE Detailed description: Install underground service to Tigard school and/or utility agency. ❑ TYPE 2—Sidewalk/Driveway/Sewer PGE Job M2480441 Work performed for the purpose of: • Sidewalk installation or repair. • Driveway approach installation 9000 SW Durham Rd Property address/location(s): and/or repair �,t.�pp Tigard, OR 97224 • Sanitary sewer lateral installation and/or main line tap Applicant: Portland General Electric ❑ TYPE 3—Full scale Development Address: 10800 SW Avery St Work performed with Land use approval which includes any of City/state: Tualatin, OR Zip. 97062 the following- Phone: ollowingPhone: 503-464-7777 Email: preregcoord@pgn.com • Subdivisions or Partitions Contact name: James Chrisman Phone: 503-736-5749 • Street widening • Mainline installation for Sanitary Contractor: Prairie Electric sewer, Storm sewer, Tigard water CCB#: 60178Expiration: and/or Tigard Water Service Area Address: 6000 NE 88TH St SUBNHT COMPLETED APPLICATION TO: City/state: Vancouver Zip: 98665 City of Tigard Phone: 360-608-5547 Email: k les prairielectric.com Planning/Engineering 13125 SW Hall Blvd. Contact name: Kyle Spencer Phone: 360-608-5547 Tigard,OR 97223 Applications for"minor work in right-of-way" Engineer: GI u mac only may be emailed to: 900 SW Fifth Ave, Suite 1600 Address: rowuermitsCgf=rd- r.gov City/state: Portland, OR Zip: 97204 Phone: 503-227-5280 Email: bbliatout@glumac.com Case No.: p-FL 2�o vs`n024-7- Contact name: Brien Bliatout Application submittal fee(.007%of Engineer's Estimate) $ Estimated value of work is required(if over$5,000):$ 51,224.45 Additional fees: $ __� (within the public right-of-way) Application accepted: By: Date: 1 Is work related to a LAND-USE DECISION? ❑ Yes No If so,please specify (MLP,SDR,SUB,etc.) case #: Application reviewed: By: 66 Date: '1 Is work related to a BUILDING PERMIT? ❑ Yes No Applicant notified: If so,please specify(BUILDING PERMIT)case#: By: �� Date: I:\ENG\PermitApplications\pfi—application Rev.10/16/2017 City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 www.tigard-or.gov • 503-718-2421 • Page 1 of4 APPLICANTS NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.041.140. * With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided or submit a written authorization with this application. Franchised Utilities are not required to obtain the owner's signature on the application BY SIGNING BELOW,THE APPLICANTS) SHALL CERTIFY THAT: • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject propem. • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. Applicant/Authorized Agent's signature Print name Date SIGNATURES of each owner of the subject property, if required. (Wu44.i STEVE HURSH 9/17/2018 Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 • Page2of4 DEVELOPMENT ENGINEERING FEES YOR STAFF VSE' ONLY Public Facility Improvement(PFI)Permit: DETAILED StT13MITTAL APPLICATION FEE Part 1: Required submittal fee$300.00 (minimum) FRANCHISE UTILITY AND SIDEWALK/ DRIVEWAY AND UTILITY PERMIT FEE CONNECTIONS,ETC. Part 2: All non-water system improvements (work in the right of way) Engineer's estimate X 5%(less$300.00 minimum submittal fee) Sketch Engineer's estimate X 2%Plan Review (including information below) ❑ Dimensions WATER SYSTEM FEE ❑ Street Name Part 3: All public water system improvements ❑ Site Address Engineer's estimate X 12% FULL SCALE DEVELOPMENT PFI Permit Fee Exemptions: (Subdivisions/Partitions and Street Improvements) There will be no permit fee charged,or assurance required for the following types of work: Design Plans • Sidewalk repair(less than 20 lineal feet) (G sets,24x36 or 22x34) • Relocate or replace mailbox ❑ Cover—Site,Vicinity,Abbreviation,Legend • Ditch cleaning that does not involve regrading. ❑ General Notes(City,Water,Sewer,etc.) • Weep hole repair ❑ Street(Plan,Profile) • Curb repair or replacement(less than 20 lineal feet) ❑ Water,Storm and Sanitary(Plan Profile) • Lawn sprinkler system installation or repair ❑ Water Quality Facilities • Street tree pruning or planting ❑ Grading • Planter strip landscape maintenance ❑ Landscaping/Tree Plan • Test wells ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm,Sanitary,Water,Signage,Street Lights,etc) ❑ Details Note. A cash/band assurance maybe ❑ Traffic Sight Distance required per TMC 15.04.140. ❑ Signing and Striping (customer deposit) ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers) Additional Submittals (per Land Use conditions) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design(if applicable) ❑ Water Department approval ❑ Engineers Construction Estimate fw mdWt:v^ato-f+•c -.n„..r.s„a:.&3xraM�a..u.w,:+i` «:a"ea k' -wr>�aix 'y ••..,. --.,� tie,�..—"s�a��.�.�•r. sxasAvtu�:. +vr PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 3 of4 SAMPLE SKETCH: _ ,• �_ „ � Edge of Pavement I I Ditch Streetlight I l.—.—•�•—.—•—.lr—.— f• Rain Dmin I � f �• r;r_r. .y � a I I ' T— ropV d�5elgnr—e 7rW]'” M� I Existing House 1 g Existing � zi i Driveway 3� 1 al � CI I ;h• w �J a arka. I 13' a 'I a. I Existing Shop � ' 1 Powerpole �. • Q I I S5 ' 1 '------- ------_--- . I � T�roperiy L ni e- I Fire Hydrant(FH) I I I I Scale: 'I"=30' � � I I I I ' I I I I I I I MINIMUM SKETCH REQUIREMENTS(Put"N/A"if Not Applicable): North arrow Property lines &dimension Slope of property Street &street name(s) Existing building,structures Utility&street light poles Proposed work Existing curb or edge Trees Existing S/W or of pavement Existing utility locations D/W apron (sewer,water,storm) PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard - 13125 SW Hall Blvd. - Tigard,Oregon 97223 - www.tigard-or.gov - 503-718-2421 - Page 4 of4 29 52 • LIDS 294 9 �, 25 11231 COMMERCIAL LEGEND z Vr20 , 25 4 ------ ----- -------------- _ 1990 2 --- - '�G wr- NEW PGE FACILITIES TO BE INSTALLED Feeders 1 C2 1-11D (UNLESS OTHERWISE SPECIFIED) ,8 SW DURHAM RDWj 810-PGE PAOMOUNT VAULT, PROVIDED 8 INSTALLED BY CUSTOMER C 15 1003 2000 L 2000 0 FAULT INDICATOR 240 3-14365T 1 45< 1 1S82 ......... � _ � CONDUIT,PROVIDED XP R VlDED dINSTALLED BY CUSTOMER 5�Ogg CUS70MER 30'_ 1 1964` 1 ---------INSTALL 7-350 AL-OX UG SECONDARY IN 7 OF 16-3"PVC CONDUITS,PROVIDED d INSTALLED BY CUSTOMER L `JSTOMER TO INSTALL 3-3"WC(!>rJDl11' WFOR TFMP I OF 3-4L0 AL-OX SERVICE ~ R�1 Onn 1 Z L i F3D-34 1 INSTALL: 1 ABC 101 321 • 1 Transformer-Three Phase Underground PD-7375 L 3P 12.5f7.24801277PM1500KVA NTLB 1 1 1 630'; THINK E PD 34 ABC 1500 SAFETY 72' FIRST! 5067 30'•6 TEMP INSTALLED-- - O N 19 ON M2554783 C21-141q 3 2771480V y GEAR WALL 3000AMP 142 6 T 81035617 .63%VD Rmd Sidc x4•• -_ 2406 T 1.64%FLKR Typi-I 40'1`) 50,842A AFC • 1969 O®O®� LEGEND ®®®©© 30„ (D PGE Primary 31" Mie S—dery CAhk FRONT OF GEAR MG C__ 1-6de Deet Teeeeh O Telco'CATV 1e ®11—kELB SelecU BAekBll Uedismrhed Eu+h jMWUu Treeeh W.0 Gu • • CONSTRUCTION NOTES: CMDEV I CUSTOMER IS RESPONSIVE FOR ALL TRENCH,CONDUIT,VAULTS,PMS AND ROM CROSSINGS, 2.ALL CONDUIT TO BE INSTALLED WITH 30 INCHES(MM)COVER AT TOP OF CONDUIT 80290 FROM FINAL GRADE. 2 32 3.ALL PGE CONDUCTORS TO BE INSTALLED M GRAY,SCHEDULE 40,ELECTRICAL GRADE. PVC CONDUIT WITH NYLON PULL STRINGS(MM 500 LBS,TESTI.PGF TO DETFRMINE ' S 30-�. THE SIZE AND NUMBER OF CONDUITS REQUIRED MAINTAIN 13 WATACAL INCHES AND SW MARTHA ST 2010 24 HORIZONTAL INCHES CLEARANCE BETWEEN GAS AND OTHER UTILITIES ALL ELBOWS 4 INCH 6 SMALLER TO RE 36 INCH RADIUS ALL BENDS MUST BE FACTORY MADE. ALL ELBOWS URGER THAN 4 INCH TO BE 60 INCH RADIUS.RIGID STEEL OR PGE C*FOR FD.FDERGLASS BENDS ARE REQUIRED FOR RUNS OF 151 FEET OR LOPK�ER. OR FOR ANY LENGTH RUN WITH MORE THAN IBD DEGREES IN BENDS,IWC SCHEDULE 40 BENDS ARE ACCEPTABLE FOR RUNS OF 150 FfET OR LESS.THE MAXIMUM TOTAI BENDS N ANY CONDU M IBM 6 270 DEGREES. 4 DIRECTIONAL BORING RFQUIRFMFNTS BUCK HDPE HIGH DENSITY POLYETHYLENE)DUCT 09 SCHEDULE 40 PVC WITH A MECHANICAL CONNECTION(CERTA-LOK OR CAKE MECHANICAL CONNECTION PRODUCT)AS AN AL TERNATNE TO HDPE DUCT.HDPE SHALL MEET THE RIGHT-OF-WAY PERMIT NOTICE: Ri NAGER)f oR WEOF TY REASONS THE DUCTTION SHA515 LL BE BLACKOWITH REQUEST THREE EOUALLY SPACE EXTRUDED RFD STRIPES/WHICH IS A SPECIFICATION RFOUIREMFNTI MANDREL TEST OF A PERMIT FROM THE LOCAL JURISDICTION IS REQUIRED BEFORE ANY _p,PIPF"RroulRFn AF+FR 1NS7 >_WITH PrF INSPFCTn,d PRFtFNT WORK IN THE RIGHT-0F-WAY MAY BE PERFORMED. ONLY PGE APPROVED CONTRACTORS AND CONTRACTORS WHO HAVE MADE OTHER SPECIAL 5.ALL PGE TRANSFORMERS 10 BE NAND 4 B FEET punk FROM AM cHADRANT,E BUILDING,GTRA WALL E OVERHANG AND 4 FEET OO((MFM)FROM AM FINE 1l1'DRAPIT. AGREEMENTS WITH PGE WILL BE ALLOWED TO WORK UNDER PGE'S PERMIT, ALWAYS NTTAIN W F�EETVCL E WrrMN IN FRONT Of ALL DRIVEAW HERS THE CONTRACTOR MUST NOTIFY THE LOCAL JURISDICTION 48 HOURS BEFORE WORK IS TO BEGIN.A COPY OF THE PERMIT MUST BE ON SITE. 6. TRANSFORMER PADS ARE TO IF SET SO THAT THE TOP IS 2 INCHES ABOVE "AL GRADE.CONDUIT IS TO BE INSTALLED IN PAD AS INDICATED IN DETAIL AND TO EXTEND I INCH ABOVE THE PM 7.STEEL BARRIER POSTS ARE REQUIRED AROUND TRANSFORMERS THAT ARE EXPOSED TO VEHICLES. B.ALL SWTCH VAULTS TO If SET AT FINAL GRADE WITH 6 INCH GRAVEL BASE AND CONDUITS ALIGNED TO ENTER THE VAULT END LOWER KNOCKOUTS ITERM-A-DI/CT$). 810—PGE VAULT (SEE DETAILS ON SKETCH 3 PHASE,PADMOUNTED 9.PGE TO BF NOTIFIED AND INSPECT ALL CONDUIT,VAULT AND FAD ITALIA BFfORE SACXML,ALL NES+'VAULT S PAD ICJCAlIONS t0 BE FIELD vFRIFIED NOTES: WITH PGE AND CUSTOMER REPRESENTATIVE Q 1.VAULTS TO BE p.ROPER TO PGE ELECTRICLRRIAI AL SERVICE REQEMMS BOOK POR RM DETAILS CN4 SET LOCATIONS 8 SPEC REQUIREMENTS.11NK i0APPROVEDAROVED BY IGF. a� il.UDESIGNPIDER 6 MSFD ON STANDARD I AN OPTION EGUIPMENTADDITIONAL NON-STANDARD Z.TOP OF LID TO I/1VDERCsROUND EWIPMEM MAY BE AN 171170N AT AN ADOf11OHAL[OST 10 �. ,- �AT RNAs CONTACT SERVICE COORDINATOR TME CUSTOMER APPROVED BY IC,E FOR I NCH AND CONDUIT IHSKCTION Pit" 12.THE POINT Of DELIVERY AND DIVISION nF nwNEP<HIP PETWFEN THE CUSTOMER AND J r0 ILMCKNLL PGE WILL HOT INSTALL WIRE PGE WILL BE AT THE LINE SIDE OF THE F+S`.+ ""n`.1'P PRDVIDED 1111 GEM. 3.DO NOT CROSS UNTIL TRENCH Is wonftp BACKNLLED • PVC BETWEEN 503-323-0]00 OR 80 �1M/sAL.EA+f SDPMfNG REVIEW: ASBUILT BY DESIGNER: 011 4,INSTALL 500 Le DATE'.8242018 SMT KIS AccaMT 1070001 AWO:1000004599 No.M2480441 4"FROM •; �• Be 03 �T"�RlIn IN EM/11ACH Poc. ANY DEVIATION FROM THIS DESIGN MUST n` SCHOOL DIST 23J--HIGH SCHOOL `7 20 M •ew 4�►2 BE APPROVED BY PGE PROJECT MANAGER nRcuIT — -0�.40 T �i DURHAM-SATTLER 17NL22 as o . PD-34 Wo O B 2 rrENnoN CALL 811 BEFORE YOU DIG PGE LOCATION v' ` 9000 SW DURHAM RD,TGARD E• OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED BY THE OREGON UTILITY NOTIFICATION CENTER. DESCRIPTION 1L' THOSE RULES ARE SET FORTH IN OAR 952-MI-MIO , 3000 27714W UG 3P SERVICE/MAECM DEMOLITION AND RESTORATION TO TIGARD SCHOOL J_ \\/ r6 3 TO GEAR MEETING I TRENCH AND CONDUIT INSPECTION THE RULES BY CALLING THE OREGON UTILITYTHROUGH 952-001-009D YOU MAY OBTAIN COPIES OF BEAVERroN WASHINGTON C14A WORX WItH 1 YOUR PROJECT REQUIRES A PRECONSTRUCTION MEETING.CONTACT YOUR SERVICE d DESIGN NO17F1GLTON CEW R AD WNATMTKW 0 IS03-232_pB7� LINE CREW CENTER PROJECT MANAGER 7 TO 10 WORKING DAYS PRIOR TO EXCAVATION TO COORDINATE THE DESIGN BY /HOME(503) DRAWN BY PRE-CON.PGE'S FIELD CONSTRUCTION COORDINATOR(FCC) WILL PROVIDE YOUR TRENCH TO REQUEST UTILITY LOCATES CALL THE OREGON Knew wlleEl below. ne SW HBm aR Jams Chri—ri 736-5749 LANE WHITNEY AND CONDUIT INSPECTIONS. UTILITY NOTIFICATION CENTER,871 AT LEAS' COSI .bel d 2 BUSINESS DAYS PRIOR TO EXCAVATION. la+IY- 0 PORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED PORTLAND GENERAL ELECTRIC Signs:48"x 48" reflective w flags Spacing: 100' 9000 SW Durham Rd Tigard Cones:28" reflective Spacing: 20' Four certified flaggers to set up, control intersection w lights off, alternate PGE Contact: Deanna Kaneshiro one lane of traffic thru intersection, assist pedestrians and bikes and remove 503-672-5437 all traffic control at the end of work. deanna.kaneshiro@pgn.com V) Field adjustments will be made as needed for safety. Job #M2480441 D a ODOT and MUTCD standards will be followed. a w°o , �O CO i oo ::EI � Z7 T I < I o ON Assist cars exiting 1 ;o QA RIM hru work area. I `WoTEA Z � bo PD21 SW Durham Rd g r VT20 T' ► o ' aLANE--- .--- 1 --1 !_--� +—M — F OF <>4 _� -I �- -�- ..- ••• ORK AREA SIDEWALK ----- —� �.---- `SW Du r a m R wpRN M[�Al1Ep •�1 CLOSED I IAF/1 HIGH SCHOOL • ; PD34 - , '. � a MANIFEST 4Isco 6 Road Work Ahead I 70 SfQF U:) 3 Be Prepared to Stop NOT TO SCALE Q, 3 Flagger Ahead > 1 Right Lane Closed Ahead „ 1 Bikes on Road 2 Sidewalk Closed/arrow left 1 Sidewalk Closed/arrow rt Prepared by: Lord and Associates, Inc. 141004 503-777-4902 4 Certified Flaggers Debbie McCann,TCS 40 Cones September 4, 2018 flaggers@aol.com