PFI2018-00244 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
COMMUNITY DEVELOPMENT Permit#: PF12018-00244
Date Issued: 09/19/2018
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421
Parcel: SEG1394
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: NW Natural
Project Description: SEG 1394/ 1151. Intersection of SW Wall and Hunziker. Offset 136'of 2"(P)main by 3'due to storm
water facility. New main offset will be 3'from west ROW of SW Wall Street. Will also be shortening and
reconnecting service feeding 7930 SW Hunziker.
Owner: FEES
Description Date Amount
PHONE:
Contractor:
PHONE:
FAX:
Applicant:
JAMISON FORGE
220 NW 2ND AVE
PORTLAND, OR 97209
PHONE: 503-226-4211
Total $0.00
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
PermitteelApplicant
Signature: See application
Issued By: --- --� ziiL��.....
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12018-00244
Type: Condition Name: Status: Severity:
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of
any agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited
and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up
and suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be
reinstalled or replaced,with like kind of material. Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition, American Traffic Safety Services
Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work
area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be
effectively maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and
area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met)
and 503-431-2345(Tigard School District)and other service providers impacted by such closure.
PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the
City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9:00 a.m. unless authorized
by the City Engineer.
PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987.
If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole
before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at
the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work
with affected utility agencies.
PFI_Utilities 14-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by
the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert
Phone#>,to establish a preconstruction meeting.
PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work,prior to any staged
inspection, and after completing work covered by the permit.
PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 19-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have
authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI_Utilities 21 -OTHER Applied Notice
RECEIVED
City of Tigard SEP 17 2018
;y Pl-'13I-.IC WORhS — ENGINEERING CITY OF TIGARD
��Permit
ANNING/ENGINEERING
APublic Facili Im rovement (PFI)
01� �_�a►` ' 11',� ......� _: �za.
�--: �.c
. ,=,-.,:�:�a.:•- - - - -- - —;<T---
Y TYPE OF WORK
DESCRIPTION OF WORK(in the right-of-way) El TYPE 1—Franchise Utility%York
Check one: 0 Utilities ❑Sidewalk/driveway approach Q Street improvements performed by N\X'N, PGE
Offset 136'of 2"(P)Main by 3'due to storm and/or utility agency.
Detailed description:
water facility. New main offset will be T from West ROW of SW Wall St. ❑ TYPE 2—Sidewalk/Driveway/Sewer
Will also be shortening and reconnecting service feeding 7930 SW Hunziker Work performed for the purpose of.
- Sidewalk installation or repair.
Property address/location(s): SW Wall St between SW Hunziker and - Driveway approach installation
and/or repair
130'South. 96�G 3aL} I E5 I - Sanitary sewer lateral installation
and/or main line tap
Applicant: NW Natural
❑ TYPE 3—Full scale Development
PP Work performed with Land use
Address:220 NW 2nd Ave approval which includes any of
City/state: Portland,OR Zip: 97209 the following:
503-226-4211x4344 Jamison.For a NWNatural.com - Sulxli�isions or Partitions
Phone: Email: 9 �°
Contact name: Jamison Forge Phone: 503-226-4211x4542 - Street widening
- Mainline installation for Sanitan
sewer, Storm sewer,Tigard water
Contractor: and/or Tigard Water Service Area
CCB#: Expiration:
Address: SUBMIT COMPLETED APPLICATION TO:
City/state: Zip. City of Tigard
Planning/Engineering
Phone: Email: 13125 SW Hall Blvd.
Contact name: Phone: Tigard,OR 97223
Applications for"minor work in right-of-way"
only may be emailed to:
Engineer: rowognnitsadgard-or.gov
Address: MEMMMUMMIEW
Citi-/state: Zip: L
Phone: Email: Case No.:W«io—co-2144
Contact name: Application submittal fee(.007°/x,of
Engineer's Estimate) $
Estimated value of work is required(if over$5,000):$ Additional fees:$
(within the public right-of-way) application accepted:
By: 165t— Date: 11 18
Is work related to a LAND-USI- DECISION? ❑ Yes 0 No
If so,please specify (MLP,SDR,SUB, etc.) case #: Application reviewed:
By: 15Date: 6t 1 C1
Is work related to a BUILDING PL-''RMIT? ❑ Yes No Applica t no<fied:
If so,please specify(BUILDING PERMIT)case#: By: Date: qhqh�7
I:\ENG\PermitAppliotions\pri application Rev.10/16/2017
City ofTigard • 13125 S\t'I-Iafl Blvd. Tigard,Oregon 97223 - wwx%:tigard-or.gov - 303-718-2421 - Page 1 of4
APPLICANTS
NOTE: Person specified as"Applicant"shall be designated "Permittee"and Miall provide financial assurance for«•ork,if
required by the city pursuant to TN1C 15.041.140.
11Vith the exception of a utility operating pursuant to a valid franchise with the laity of Tigard,when the owner and the applicant are different
people,the applicant must he the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the
owner. The owner(i)must sign this application in the space provided or submit a written authorization with this applicatiOn. Franchisrd
Utilities arc not required to obtain the owner's signature on the application
BY SIGNING BELOW,THE APPLICANTS)SHALL CERTIFY THAT:
• The above request does not violate am,recorded deed restrictions that mar-be attached to or imposed upon the subject
proper .
• If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
• All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and
the applicants so ackno«ledge that any permit issued,based on this application,may be revoked if it is found that any such
statements are false.
• Tile applicant has read the entire contents of the application,including the policies and criteria,and understands the
reyiu-remcilts for approving or denying the application.
Jamison Forge 9/14/2018
G�
Applicant/Authorize gent's sikdature Print name bate
SIGNATURES of each owner of the subject property, if required.
Owner's signature Print name late
(hvner s signature Print name late
Owner's signature Print name late
PUBLIC FACILITY IMPROVEMENT PERMIT
Cit-s' ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov 503-715-2421 Page 2 of
CROSS SECTIONS GENERAL NOTES N
I-Call the following I)Iilines Notification Center
70'
----- —----- _. :. 48 hours prior to ari excavation.
Oregon 811 or 1-900-332-2344 W E
J 14' 21' 21' 7' 7' Washington 911 or 1-800-024-5555
2.ATTENTION:Oregon law requires you to follow c
d ♦ rules adopted M the Oregon IIWih-NotificationS
p O CD C f9 tM Center Those rules are set forth in OAR 952-001-
E '0 B L B W C E 1X190 You may obtain copies of the rules 1-6,calling
the center.(Note:the telephone number for the Oregon
Utiluw Notification Center is(503)232-1987 or 91 l)
3.Fill out construction sketch as-built supplied with
3, job packet and return with work order Oidv one
as-built is required. TLS
0*—6'EX. MAIN 4 All distribution mains must have a minimum depth of
24"and services most have a minimum depth of 18"
W/S SW WALL ST E/Sunless there is an approved variance
5.All transmission lines must have a minimum depth of
30"in Class'F locations and 36"in Class`_i,8r.4' X59 `D V�/��A�� ✓ �Q
locations.unless there is an approved variance ��
VSE 8 6 Written dimensions on this construction sketch 'V�
venarca(s)medr: have precedence over staled dimensions ?�W.
7.Pressure lest shall lie tested in accordance with ��g � 2Oco
standards in CFM and Engineering Standard Practice O }
Rgaon h)' 8.Test medium foi class"B"main shall be an,unless
otherwise noted.Test medium for class"C-F"main ley 2 ti�
k ipit—t.k.n(n-,),). shall he water,unless otherwise noted O
9,For Class C or higher tests,see Design Document and 71 `
Apprwd Niru- sip eh.s Drs Hydrostatic Report ? 4y
C; Ary nj qo
Class"B"PRESSURE TEST INFORMATION(circle&label test area on as-built drawing) Q s• ,' 1 �� a rrw s
Test by NNG—Other
Tat Pp. SI.M- Pp. T.r ON ors ►aa O.ay. Prkr N"oor.nE Yat1r �\ 'S r'07 Or /O
At Sir. PcN Fe tM. P_ Dr. TM. De. Tit- YIN
A 3a 01
B A.
C �4.
FUSE
D O 3'OFFSET
E
m
FNT
'
Order Street Description Plat number Costing Pipe s¢e Type
3552611 7930 SW Hunziker St Abandon T of 1"(P)and Reconnect 11-043-021 IZ314 P-0100 SM05 --0 FUSE
0 3'OFFSET
CO
WELDS m
%X- CERT. OPER. PM PM ' c� v
FOOTAGE SIZE M P GRADE W.T. RAYED MAOP MAOP NOP ACTIVITY At ORDER# ti
INSTALL 136' 2" P B P24 .216 60 57 45 114 03552607
ABAN 130' 2" P B
� y
NW Natural So 100
Feet
Engineering Department t in=100 ft
ADDRESS CITY COUNTY STATE DESIGNED KDB DATE 09/13/201
7930 SW HUNZIKER ST TIGARD WASHINGTON OR DRAWN KDC DATE 091131201
BETWEEN AND
SW HUNZIKER ST END OF SW WALL ST APPROVED R2G DAA 09/14/201
NAME CREW LDR. DATE
SW WALL ST MAIN OFFSET PLATTED DATE
PUTT TNM RNO SEC PIPELINE ID JOB TYPE
-
1-043-021 T02S R01WNW 1 PUBLIC WORK MAINS
PM R: PROJECTIREVISIONA
03552607 00022451
Page 84 2011 Edition
Stationary Lane Closure with Flagging Diagram 320
Diagram 320 covers total closure of one lane of a two-lane,two-way
roadway. See the detail inset for the layout if using a single flagger to control
both directions of traffic on low volume roads (less than 400 ADT)with good
sight distance as discussed below.
1. Use truck-mounted flashing warning lights on work and protection
vehicles. See Section 4.3—Lights and Lighted Signs for exceptions.
2. For added visibility, a truck-mounted arrow board or PCMS in caution
mode may be used.
3. Flaggers at each approach are required if any of the following
conditions exist:
a. Night Operations.
b. Work space is over 200 feet in length.
c. Sight distance is less than 750 feet from each approach
through the lane closure.
d. Traffic volumes are greater than 400 ADT.
4. The length between the Flagger Ahead signs shall not exceed one
mile. Use Diagram 340—Lane Closure with Pilot Car if exceeding one
mile.
5. Cones should be used to outline the work space when curves or other
roadway alignments prevent clear direction for the motorists to pass
the work space safely.
6. Cones along the work space are recommended when posted speeds
are 45 mph or greater, when working under heavy traffic or when travel
lanes are narrower than 11 feet.
7. Extended queue signing (see Diagram 5-4)should be used when
traffic queues extend beyond the initial advance warning sign.
8. When flagging near an intersection, the "Flagger Ahead" (CW23-2)
sign should be visible to traffic entering from any side road. Additional
advance warning and Flagger Ahead symbol signs may be placed on
the side road(s).
9. Sign set-up and flagger placement shown may be used for intermittent
full road closures of 20 minutes or less.
10. The "ONE LANE ROAD AHEAD"(W20-4) sign is optional and should
be considered on high volume or high speed roads, or when extended
queues are expected.
Chapter 5 December 2011
�, � ------------------------ o
aa Single Flagger Operation
CD for Low Volumes (Optional) o' a
N wo I (ADT<400) ,o � I z =!
00 0 o D d I I BE o
PREPARED ONE LANE
W Q I A e H e H c I� I TO STOP AHEAD r—
o (0 71 o W W I ,,,�' — — — I
0 0 0 I — — .. I ROAD
WORK
Cn Wa, `D I KcKeKeKA 4--J I AHEAD O
0 0 C> Cn C n= m Bomar __
y %WTM 4 I N
,N-+ VCnL 44�>
CT W 0 N O- 9 I I
0000cno Cc)� PP" I t
A B B
I--------- ------------J
_ 1 mile _I -n
r max. !v
�Q
B
Buffer
Protection Vehicle
Tt
ROAD
w/TMA(both Optional) v
See Chapter 4
WORK •
AHEAD �.
BE T �
ONE LANE
ROAD TO STOP Two Flagger Operation 3
w CD
Lco
cn (Optional) p Cn