Loading...
Report ci +r Sw L Sh . -, , f2'4. ' to 1.1 SEP 122018 C!T y BUILDING SIEMENS 15201 NW Greenbrier Parkway Suite A-4 Beaverton,Oregon 97006 Phone: (503)207-1900 Fax:(503)207-1901 OFFICE COPY FIRE ALARM SUBMITTAL Washington Square Lucky Brand Submittal Version Date Siemens Job Number 44op-246074 Issued for Review 09.06.2018 Siemens Project Manager Moses Frangopolous Siemens Project Engineer Garrick Youngberg,SET Proprietary document for approval only TABLE OF CONTENTS SIEMENS BILL OF MATERIALS & COMPONENT SPECIFICATIONS FIRE ALARM POWER SUPPLY BATTERY AND VOLTAGE DROP CALCULATIONS :;) �w« !0:41 ( ��\ � 6\ > *, ��\ � . . BILL OF MATERIALS SIEMENS FIRE ALARM SUBMITTAL Washington Square Lucky Brand Fire Alarm System Panel Components Item Model# Siemens Part# Quantity Color Mfg Description 1 E60H-24MCC-FW 7 White Wheelock Multi-Candela Speaker/Strobe-White,Ceiling Mount-High Fideli 2 STW 2 White Wheelock Exceder Multi-Candela Strobe-White,Wall Mount 3 TRI-R 500-896224 1 Siemens MXL Control Relay Module w/Monitor Point 4 FP-11 500-095112 1 White Siemens MXL Smoke Detector-Photo 5 FDBZ492 554319-B22-A1 1 Grey Siemens Air Duct Housing * Catalog Cut Sheets not available PROPRIETARY DOCUMENT FOR APPROVAL ONLY 9/6/2018 Effective January 2016 Technical Data TD450017EN Supersedes January 2015 Wheelock E5OH & E6OH High Fidelity Speakers & Speaker Strobes Description :rt The Wheelock E50H Wall and E60H Ceiling Speakers and Speaker q# f Strobes are designed for high fidelity sound output for indoor applications. With the widest frequency response range(300 to 8000 Hz)in the industry,the EH product line features leading r intelligibility with crisp,clear voice messages and tone signaling, ideal for emergency communications, mass notification,and voice { evacuation. Providing a sleek aesthetic appearance,the wall and ceiling appliances feature dual voltage(25/70 VRMS)capability and • "" • field-selectable taps from 1/8 to 2 watts. For faster and easier installation,the low profile design incorporates a speaker mounting plate,and each model has a built-in level adjustment feature and snap-on cover with no visible mounting screws. •:: ::::•• ; For visible signaling to meet the hearing impaired,the Series EH • •:• ;�;;:; Speaker Strobe models incorporate the low current draw of the RSS ••••.:•'.•.;% �' Strobes. :,. ;•• Strobe options for wall mount models include Wheelock patented • 2 MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field „ ice selectable 135/185cd. Ceiling mount models are available in Wheelock patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The strobe portion of all Series EH Speaker Strobes may be synchronized when used in conjunction with the Wheelock DSM ._ Sync Modules,Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. Series EH Speaker Strobes are UL Listed for indoor use under t Standard 1971 (Signaling Devices for the Hearing-Impaired)and Standard 1480(Speaker Appliances),and ULC listed under CAN/ ULC-S526(Usual-audible Signal Appliances,Fire Alarm)and under CAN/ULC-S541 (Speakers, Fire Alarm). All inputs employ IN/OUT wiring terminals for fast installation using#12 to#18 AWG wiring. Color options for the Series EH Speakers and Speaker Strobes are red and white. F:T• Powering Business Worldwide Technical Data TD450017EN Wheelock E5OH & E6OH High Fidelity Effective January 2016 Speakers&Speaker Strobes Features Drawings • High Fidelity Sound Output 5.00 1-{-1.46-- • Efficient design for high intelligibility at minimum wattager. across a frequency range of 300 to 8000 HZ • 6 Field Selectable Settings in 1 Device 04111ggo <<;�'� • Wall mount models are available with Field Selectable Candela SA0 i�� Settings of 15/30/75/110cd or 135/185cd(Multi-Candela models) �I' ' or 1575cd(Single Candela model) 14� - • Ceiling mount models are available with field selectable candela °ggig ii. settings of 15/30/75/95cd or 115/177cd(Multi-candela models) • Field Selectable Taps • 1/8 watt up to 2 watts • 25 or 70 VRMS operation 2338 •___ • Easy-to-Install • Low profile design incorporates speaker mounting plate for faster and easier installation -,......„,,„„,,, j ai l'1 • Snap on grille cover with no visible mounting screws • Quick installation with IN/OUT screw terminals using#12 to Ii'l #18 AWG wires taiHregtO lip. „ga°° • 4"square backbox prevents wire damage • Series E50H-No extension ring required • Series E60H-Optional Extender(E60 Ext)is available for mounting to 4" square backboxes • Strobe Synchronization Components Figure 1.E5OH(top)and E6OH(bottom)Speakers-Front&Side Views • Meet synchronizing standards with Wheelock's DSM Sync Modules, PS Power Supplies or SAFEPATH products • Compliance • UL 1971, UL 1480, ULC-S526, ULC-S541 ( ¢ i I • Low frequency requirements of UL 464(520 Hz)to meet l NFPAs 520 Hz tone requirements for sleeping areas • California State Fire Marshal(CSFM) . , `tit, • ADA/NFPA/ANSI/OSHA li000.000.00.000.0.0 t • FCC Part 15, ICES Blv Note: All CAUTIONS and WARNINGS are identified by the symbol A.All ' warnings are printed in bold capital letters. L.J 3.020 A WARNING ,.— 229 2.223-- PLEASE .2�PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT.VISIT WWW.EATON.COM/MASSNOTIFICATION OR CONTACT EATON FOR THE CURRENT INSTALLATION INSTRUCTIONS. i.T�'�g FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR 1.01::::::°'::::::i::::),;°':::-. i �•I�i' WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION I 1 may■ AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, oo OO�o�o,00 oo 111110 I( WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR \ DEATH TO YOU AND/OR OTHERS. ' Figure 2.E6OH(top)and E6OH(bottom)Speaker Strobes-Front&Side Views General Notes • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range:' Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. 2 EATON wwv.eaton.com Wheelock E5OH & E6OH High Fidelity Technical Data TD450017EN Speakers&Speaker Strobes Effective January 2016 Table 1. Maximum RMS Current UL/ULC Max Current a 24MCW/24MCC 24MCWH/24MCCH 241575W Regulated Voltage Model Range VDC 15 30 75 95 110 115 135 177 185 E501-1 16.0-33.0 0.060 0.092 0.165 0.220 0.300 0.420 E6OH 16.0-33.0 0.060 0.105 0.189 0.249 0.300 0.420 Table 2. UL Listed Models and Ratings UL Reverberant dBA at 10 Feet b Model 1/8 watts c 1/4 watts 1/2 watts 1 watts 2 watts E5OH Speaker Strobe 73 76 79 82 84 E6OH Speaker 74 77 80 83 85 E6OH Speaker Strobe 74 77 80 82 85 Table 3. Specification&Ordering Information Mounting Sync w/DSM or Model Order# Strobe Candela Red White Lettering Wall Ceiling Options Wheelock Power Supplies Speakers E5OH-R 9863 X No Lettering X E,AA E50H-W 9864 X No Lettering X E,AA E50H-ALW 3577 X ALERT X E,AA E60H-R 9867 X No Lettering X E E60H-W 9874 X No Lettering X E E60H-ALW 3554 X ALERT X E Speaker Strobes E50H-24MCW-FR 0092 15/30/75/110 X FIRE X E,BB X E50H-24MCW-FW 0093 15/30/75/110 X FIRE X E,BB X E50H-24MCW-ALR 3559 15/30/75/110 X ALERT X E,BB X E50H-24MCW-ALW 3560 15/30/75/110 X ALERT X E,BB X E50H-24MCW-NW 3575 15/30/75/110 X No Lettering X E,BB X E50H-24MCWH-FR 0094 135/1 85 X FIRE X E,BB X E50H-24MCWH-FW 0097 135/185 X FIRE X E,BB X E50H-24MCWH-ALW 3561 135/185 X ALERT X E,BB X E60H-24MCC-FR 0187 15/30/75/95 X FIRE X E x E60H-24MCC-FW 0188 15/30/75/95 X FIRE X E X E6OH-24MCC-NW 0950 15/30/75/95 X No Lettering X E X E60H-24MCC-ALW 3555 15/30/75/95 X ALERT X E x E60H-24MCCH-FR 0189 115/177 X FIRE X E x E60H-24MCCH-FW 0190 115/177 X FIRE X E x Extender Ring E60EXT-R' 3578 X E60EXT-W' 3757 X Table 4. Specifications Physical Material/Lens(Material type) Red or white textured UV stabilized,colored impregnated engineered plastic.Exceeds 94V-0 UL flammability rating./ GE LEXAN 943A Weight E5OH Speaker:1.5 lbs(0.68 kg);E5OH Speaker Strobe 1.6 lbs(0.73 kg);E6OH Speaker:1.6 lbs(0.73 kg);E6OH Speaker Strobe 1.7 lbs(0.77 kg); Dimensions E5OH Speaker: 5"W x 5"H x 1.47"D;E5OH Speaker Strobe: 5"W x 6.74"H x 2.58"D;E6OH Speaker:7.38"Diameter x .83"D;E6OH Speaker Strobe:7.38"Diameter x 3.02"D Operating Temperature Indoor:33.8°F to 120.2°F(0°C to 49°C)and maximum humidity of 93% Mounting&Wire Connections Mounting(indoor only) 4"square backbox prevents wire damage;Series E5OH-No extension ring required;Series E6OH-Optional Extender (E60 Ext)is available for mounting to 4"square backboxes,E50 SSB,E50 SB for surface mount of E5OH Wire Connections #12 through#18 AWG Power&General Operating voltage 25/70 VRMS Strobe Output Rating UL 1971,ULC S526 Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules,PS Power Supplies or SAFEPATH products,using Wheelock patented sync protocol Frequency Range 300 Hz to 8000 Hz a RMS current ratings are per UL maximum RMS method.UL max current rating is the maximum RMS current within the listed voltage range(16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage.(l6v for 24v units). For audibles the max current is usually at the maximum listed voltage(33v for 24v units). For unfiltered FWR ratings,see installation instructions. b dBA ratings are based on testing under UL Standard 1480. c 1/8 watt tap is for private mode only. d E60 EXT is an attractive extender ring that mounts behind the speaker to permit mounting to a 4"square x 2 1/8"deep electrical box without need for an extension ring on the box. EATON www.eaton.com 3 Technical Data TD450017EN Wheelock E5OH &E6OH High Fidelity Speakers&Speaker Strobes Effective December 2015 Architects and Engineers Specifications Wheelock E50H-The speaker appliances shall be Wheelock E5OH Wheelock E6OH-The speaker appliances shall be Wheelock High Fidelity Speakers,and the High Fidelity Speaker Strobe appli- E6OH High Fidelity Speakers,and the High Fidelity Speaker Strobe ances shall be Wheelock E5OH Speaker Strobes or approved equals. appliances shall be Wheelock Series E6OH Speaker Strobes or The speakers shall be UL Listed under UL 1480 for Fire Protective approved equals.The speakers shall be UL Listed under UL 1480 Service and speakers equipped with strobes shall be listed under UL for Fire Protective Service and speakers equipped with strobes shall 1971 for Emergency Devices for the Hearing-Impaired.In addition, be listed under UL 1971 for Emergency Devices for the Hearing- the strobes shall be certified to meet the requirements of FCC Part Impaired. In addition,the strobes shall be certified to meet the 15,Class A. requirements of FCC Part 15,Class A. Bakers shall be designed for a field selectable input of either 25 All speakers shall be designed for a field selectable input of either All speakers 9 p 25 or 70 VRMS,with selectable power taps from 1/8 watt to 2 or 70 VRMS,with selectable power taps from 1/8 watt to 2 watts. watts.All models shall have listed sound output of up to 87 dB at All models shall have listed sound output of up to 87 dBA at 10 feet 10 feet and a listed frequency response of 300 to 8000 Hz.The and a listed frequency response of 300 to 8000 Hz.The speaker speaker shall also incorporate a sealed back construction.All inputs shall incorporate a sealed back construction.All inputs shall employ shall employ terminals that accept#12 to#18 AWG wire sizes. The terminals that accept#12 to#18 AWG wire sizes. The strobe portion strobe portion of the appliance shall produce a flash rate of one(1) of the appliance shall produce a flash rate of one(1)flash per second flash per second over the Regulated Voltage Range.The strobe shall over the Regulated Voltage Range and shall be of low current design. be of low current design.Where Multi-Candela Speaker Strobes are Where Multi-Candela Speaker Strobes are specified,the strobe specified,the strobe intensity shall have field selectable settings intensity shall have field selectable settings and shall be rated per and shall be rated per UL 1971 15/30/75/95cd or 115/177cd for UL 1971 at 15/30/75/110cd or 135/185cd for wall mounting. The ceiling mount. The selector switch for selecting the candela shall selector switch for selecting the candela shall be tamper resistant. be tamper resistant. When synchronization is required,the strobe portion of the appliance shall be compatible with Wheelock DSM When synchronization is required,the strobe portion of the sync modules or the Wheelock Power Supplies with built-in Patented appliance shall be compatible with the Wheelock's DSM sync Sync Protocol.The strobes shall not drift out of synchronization at modules or Wheelock Power Supplies with built-in Patented Sync any time during operation. If the sync module or Power Supply fails Protocol.The strobes shall not drift out of synchronization at any to operate,(i.e.,contacts remain closed),the strobe shall revert to a time during operation. If the sync module or Power Supply fails to non-synchronized flash rate. operate, (i.e.,contacts remain closed),the strobe shall revert to a The speaker and speaker strobe appliances shall be designed non-synchronized flash rate. for indoor flush mounting.The speaker and speaker strobe shall The speaker and speaker strobe appliances shall be designed for incorporate a speaker mounting plate with a snap-on grille cover indoor flush mounting to 4"x 2-1/8"electrical boxes without need with no visible screws for a level,aesthetic finish and shall mount to for an extension ring or surface mounting to Wheelock's E5OSB standard electrical hardware. The finish of the Series E6OH Speakers or E5OSSB surface boxes.The speaker and speaker strobe shall and Speaker Strobes shall be white or red. All speaker and speaker incorporate a speaker mounting plate with a snap-on grille cover.The strobe appliances shall be backward compatible. finish of the Series E5OH speakers and speakers strobes shall be The speaker shall be listed to the low frequency requirements of UL white or red. 464(520 Hz)to meet NFPAs 520 Hz tone requirements for sleeping The speaker shall be listed to the low frequency requirements of UL 464 areas. (520 Hz)to meet NFPAs 520 Hz tone requirements for sleeping areas. UL 1971, UL 1480, ULC-S526, ULC-S541,CSFM, FCC. UL 1971, UL 1480, ULC-5526, ULC-S541,CSFM, FCC. Note:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Eaton standard terms and conditions. re CMAn ISM 11111110111 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Life safety&mass notification solutions 273 Branchport Ave. Long Branch,NJ 07740 www.eaton.com/massnotification ®2016 Eaton All Flights Reserved Eaton is a registered trademark. E Printed in USA Publication No.TD450017EN All other trademarks are property Powering Business Worldwide January 2016 of their respective owners. HN Series Effective October 2014 HS Series Technical Data TDOO1O17EN Supersedes May 2013 ST Series Exceder Strobe, Horn Strobe, and Horn Notification Appliances Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list,including the most candela options in one appliance, low current draw,no tools needed for setting changes,voltage test points, 12/24VDC operation, universal $ mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high FIRE efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe / models feature an industry first of 8 candela settings on a single 1 appliance. Models with an audible feature 3 sound settings(90,95, . � *77 99 dB).All switches to change settings,can be set without the use �j of a tool and are located behind the appliance to prevent tampering. cj -K / Wall models feature voltage test points to take readings with a NA" /77 / voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification f I appliances feature a Universal Mounting Base(UMB)designed to simplify the installation and testing of horns,strobes,and combination horn strobes.The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust, paint and damage to the contacts.The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed.The UMB allows for consistent installation and easy replacement of appliances if required.Wall models provide an optional locking screw for extra secure installation,while the ceiling models provide a captivated screw to prevent the screw from falling during installation. E:T�N Powering Business Worldwide Technical Data TD001017EN HN Series Effective October 2014 HS Series ST Series Features • Environmentally friendly • Sleek modern aesthetics ii Low current draw • Finger slide switches • Up to 9 models now in 1 appliance draw® • Voltage test points • 12/24VDC on a single appliance • Multiple voltages • Easy to remember model numbers • 3 Audible settings O Patented • 90,95, 99 dB Note:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. • Industry leading-8 candela settings on 1 device . Wall: 15/1575/30/75/95/110/135/185 A WARNING • Ceiling: 15/30/60/75/95/115/150/177 PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING '. THIS PRODUCT.VISIT WWW COOPERNOTIFICATION.COM OR CONTACT ' COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range" • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Universal mouting base • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to • Ceiling and wall 120°F (0°C to 49°C)and maximum humidity of 93% (±2%) UL • Mounts to 5 backbox types: 1 gang,2 gang,4" square, 464(85% UL 1971). 3.5"octal.&4"octal. (100mm for international customers) • Series Exceder horns are under UL Standard 464 for audible Universal mounting base Contact cover signal appliances(Indoor use only). s oil ,..'''',.e4'14 i Compatibility and requirements tii„ €a P�1 ,a • Synchronize using the Wheelock®Sync Modules or panels with 3 �: built-in Wheelock®Patented Sync Protocol Compatible with UL"Regulated Voltage" using filtered VDC or �� '''''''''''',S'4unfiltered VRMS input voltage .$`-' 1 • Strobes produce 1 flash per second over the "Regulated Voltage" range Common base for wall and ceiling with 5 mounting options Compliance • Voltage test points for quick troubleshooting and easy spot • UL 1971, UL 464, ULC,CSFM, FM checking(wall models only) • ADA/NFPA/ANSI/OSHA • RoHS ....- ,, „ ---\\ 2 EATON www.eaton.com HN Series Technical Data TD001017EN HS Series Effective October 2014 ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® 24VDC/24FWR 12VDC Regulated Voltage Model Range VDC 15 15!75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 &Anechoic at 24VDC UL Max Current®at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current®at Anechoic 95 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current®at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ®UL max current rating is the maximum RMS current within the listed voltage range 116-33 VDC for 24 VDC unitsl.For strobes the UL max current is usually at the minimum listed voltage 116 VDC for 24 VDC units).For audibles the max current is usually at the maximum listed voltage 133 VDC for 24 VDC unitsl.For unfiltered ratings,see installation instructions. Table 3. Horn Ratings per UL Anechoic Model Legend Regulated Voltage HN = Horn R = Red Model Range VDC 99 dB 95 dB 80 dB HN 16-33.0 0.064 0.044 0.022 ST = Strobe A = Agent Lettering(strobes only( HNC 16-33.0 0.084 0.044 0.022 HS = Horn Strobe AL = Alert Lettering(strobes only) HN 8.0-17.5 0.047 0.026 0.017 C = Ceiling Mount N = No Lettering(strobes only) HNC 8.0-17.5 0.047 0.026 0.017 W = White Example 1:STRC=Strobe,Red,Ceiling Mount Table 4. Specification&Ordering Information Example 2:HSR=Horn Strobe,Red,Wall Mount S nc w/DSM or Example 3:HSW=Horn Strobe,White,Wall Mount Wheelock Power 12/24 Mounting Example 4:STW-AL=Strobe,White,Wall Mount,Alert Lettering Model Strobe Candela Supplies VDC® Options Horn Strobes s6 r, HSR 15/1575/30/75/95/110/135/185 X X UMBO e- HSW 15/1575/30/75/95/110/135/185 X X UMBO v /T HSRC 15/30/60/75/95/115/150/177 X X UMBO ' Ay HSWC 15/30/60/75/95/115/150/177 X X UMBOS �K Strobes y , STR 15/1575/30/75/95/110/135/185 X X UMB® STW 15/1575/30/75/95/110/135/185 X X UMB® STRC '15/30/60/75/95/115/150/177 X X UMB® ::: , STWC 15/30/60/75/95/115/150/177 X X UMB® I Horn ? HNR X X UMB® HNW°, X X UMBO '•, L. HNRC X X UMBO Example:HSR Example:HSWC HNWC X X UMB® ®12 VDC models feature t5&15/75 settings OO UMB=Universal Mounting Base EATON www.eaton.com 3 Technical Data TD001017EN HN Series Effective October 2014 HS Series ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances,Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service.The Series HS and HN Audibles shall be UL Listed under Standard 464(Fire Protective Signaling).All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one(1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design.Where multi- candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75,30,75,95, 110, 135, 185 candela for wall mount and 15,30,60,75,95, 115, 150, 177 candela for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.,ADA compliance).Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang,double-gang,4-inch square,3.5-inch octal,4-inch octal or 100mm European type back boxes.Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP).The mounting base shall be the same base among all horn, strobe, horn strobe,wall and ceiling models.All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58"W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D.Series HNC ceiling shall have a diameter of 6.68"x 1.50" D. When synchronization is required,the appliance shall be compatible with Wheelock's DSM Sync Modules,Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate,the strobe shall revert to a non-synchronized flash-rate and still maintain(1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464,California State Fire Marshal(CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal(CSFM), ULC, FM, RoHS Note:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Cooper Notification 273 Branchport Ave. Long Branch,NJ 07740 CooperNotification.com 0 2014 Eaton All Rights Reserved Eaton is a registered trademark. EA N Printed in USA Publication No.TD001017EN All other trademarks are property Powering Business Worldwide October 2014 of their respective owners. SIEMENS Data Sheet Fire Safety& Security Products Intelligent Detection Devices TRI Series — Intelligent Initiating Interface Modules [For use with FireFinder® XLS and MXL Panels] Models TRI-D, TRI-R and TRI-S ARCHITECT AND ENGINEER SPECIFICATIONS • Used as an intelligent initiating interface module for the FireFinder XLS and MXL fire-alarm control panels(FACPs) • Interfaces and supervises normally open (N.0)contacts • Integral single-pole,double-throw(SPDT)relay(up to 4 amps),Model TRI-R • Dual input for Model TRI-D • Multi-color light-emitting diode(LED)indicates detector status (green,amber,red) • • Simple front-end access to programming port and wiring terminals • Mounts in a 4"-square,2-1/8"-deep standard or double-gang box e "".1 • Dynamic supervision r. : t �` ""'4 • 5-x-5-inch faceplate included 4,4.1.414 • • Two-wire operation • Compatible with Model DPU or FPI-32 field programmer/tester ° t ` • Electronic-address programming is simple and dependable • ®UL Listed,€ULC Listed; CSFM and NYC Fire Department Approved Product Overview The Model TRI-series of intelligent interface The sole purpose of Model TRI-S is to monitor and modules from Siemens—Fire Safety is designed to report the status of the contact,while Model TRI-R provide the means of interfacing direct shorting incorporates an addressable'Form C'relay. The devices to Model MLC for the FireFinder XLS FACP, relay and contact device input for Model TRI-R are or to Model ALD for the MXL system, respectively. controlled at the same address. The relay and input The Model TRI-series of intelligent interface contact can be controlled as a separate function. modules provides the most advanced method of The relay is typically used where control or shunting address programming and supervision—combined of external equipment is required. with sophisticated FACP communication. Each Model TRI-D is a dual-input module that is designed to Model TRI-series interface module incorporates a supervise and monitor two (2)sets of dry contacts. microcomputer chip. In turn,the microcomputer- Model TRI-D requires two(2) address settings. Model chip technology and its sophisticated bi-directional TRI-D is ideal for monitoring a waterflow switch and its communication capabilities with the FACP,achieve respective valve tamper switch. the state of an'Intelligent Device.' Model TRI-series has a multi-color LED that flashes Specifications green when operating normally; -I � if unit is in The Model TRI series of intelligent interface trouble condition,and red to indicate a change of modules is available in three (3) models. Models status command. Model TRI-D flashes two(2) times— TRI Sand TRI-R are designed to monitor a normally once for each address, and the red LED of Model TRI-R open (N.O.) dry contact. The interface module indicates a change of state in the relay. reports the contact's status to the FACP. TRI Series —Intelligent Initiating Interface Modules 61 79 SIEMENS Industry, Inc. Building Technologies Division Specifications — (continued) Electrical Ratings The microcomputer chip for the Model TRI-series of Current Draw: 1.5mA devices has the capacity of storing—in memory— [Active or Standby] identification information as well as important Model TRI-R Relay Ratings: operating status information. 4A,125VAC Resistive: 4A,30VDC Siemens—Fire Safety innovative technology allows all Model TRI-series intelligent interface modules to 3.5A,120VAC[0.6 P.F] be programmed and tested,via Model DPU or the 73.OA,3OVDC[0.6 P.F] Inductive: 2.0A,120VAC[0.4 P.F] FPI-32 Programmer 1 Tester. Each of these 2.OA,120VAC[0.35 P.F] programmer 1 testers is a compact, portable and 2.0A, 120VAC[0.35 P.F] menu-driven accessory that makes programming and testing an interface device faster,easier and more dependable than previous methods. Mounting Diagram Model DPU or the FPI-32 eliminates the need for MouNTINeSLOTS mechanical addressing mechanisms(such as: FOR 4-INCH program jumpers, DIP switches,or rotary dials), SWI 104130X since either programmer I tester device electronically sets the address of the Model TRI- Q series into the interface's microcomputer chip, non- ° '* volatile memory. Vibration,corrosion and other TA SJo/R [ t ., MODULE conditions that deteriorate mechanical addressing [a1 2 aim mechanisms are no longer a cause for concern. ? s KM° LAI 4 MOUNTING The Model TRI-series of intelligent interface [=I 5 s HOLES FOR modules is fitted with screw terminals for 7 SWiTCHPLATE connection to an addressable circuit,and is fully compatible on the same circuit with all intelligent Model FP; Model IL and Model ID-60-series o 0 detectors; Model MSI Series addressable manual stations,or any other addressable intelligent MouraTlNrT modules,such as Model CZM or Model ICP. FON o0Ui3LL-GANG STCHBOX All Model TRI-series intelligent interface modules arebUL and'ULC Listed. Details for Ordering Model Part Shipping Weight Number Number DescriptlCa Oz. Kg. TRI-D 500-896226 Dual Input Intelligent 7 0.2 Interface Module Single-Input[wl relay] TRI-R 500-896224 Intelligent Interface 7 0.2 Module Single-Input TRI-S 500-896225 Intelligent Interface 7 i 0.2 Module Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry,Inc. Florham Park,NJ 07932 Brampton,Ontario Building Technologies Division Tel:(973)593-2600 (su-FS) L6T 5E4/Canada Supersedes 2012 5/06sheet dated FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (Rev 4) URL:www.usa.Siemens.com/Fire FAX:(905)799-9858 SIEMENS Data Sheet Fire Safety& Security Products Intelligent Detection Devices Intelligent FirePrintrM Detector [For use with FireFinder® XLS and MXL Panels] Model FP-11 ARCHITECT AND ENGINEER SPECIFICATIONS • Most sophisticated'detector intelligence'available in the Fire/Life Safety market • Multi-criteria fire detection for the price of a photoelectric detector • Remote-sensitivity-measurement capability at • Easily programmed to match specific hazard profiles from the fire-alarm control panel(FACP) • FirePrintTM technology to distinguish between deceptive tf ; phenomena and an actual fire • Pre-Alarm reporting based upon fire profile selected �� • • Field-cleanable chamber with replaceable chamber parts • System-logic activation based upon any of three(3) inputs from the detector(smoke,heat or neural network) • Supports software-based,automatic environmental compensation • • EnviroLINK ��- • Compatible with field programmer/tester • Multi color,detector status • Model DPU/FPI-32 Upgrade Kit • Backward compatible with older MXL systems light emitting diode(LED) • Rev.2 and above • Two-wire operation • Optional fully programmable relay base,audible base • aUL and OULC Listed; and duct housing FM,CSFM &NYCFD Approved Product Overview The Intelligent Fire Detector(Model FP-11)is a The upgrade kit(Models DPU or FPI-32) eliminates the highly evolved detection system that provides the need for cumbersome, unreliable mechanical most sophisticated level of fire protection,along programming methods,as well as reduces installation with superior nuisance-alarm immunity currently and service costs by electronically programming and available in the Fire/Life Safety industry. testing the detector prior to installation. Model FP-11 utilizes highly developed detection Specifications technology that allows the detector to distinguish non-threatening deceptive phenomena (i.e. — Model FP-11 is a plug-in,two-wire and multi-sensor cigarette smoke)from actual fire hazards,while detector with photoelectric and thermal inputs that is optimizing detection for the area of its intended compatible with the FireFinder XLS and MXL family of zone. Model FP-11 uses state-of-the-art FACPs. Each detector consists of a dust-resistant,field- microprocessor circuitry with error check, detector cleanable photo chamber;a solid-state, non- self-diagnostics and supervision programs. mechanical thermal sensor,and microprocessor-based Model FP-11 is compatible with the Siemens—Fire electronics with a low profile plastic cover and base. Safety Model FPI-32 upgrade kit or Siemens'field- Model FP-11 utilizes state-of-the-art ASIC and surface- programmer/tester, Model DPU/FPI-32,which is a mount technology for maximum reliability. Every compact, portable and menu-driven accessory for Model FP-11 fire detector is shipped with a protective efficiently programming and testing detectors dust cover. Model FP-11 fire detector utilizes an electronically. infrared light-emitting diode(IRLED),and light sensing photodiode. Intelligent FirePrintTM Detector 61 75 SIEMENS Industry, Inc. Building Technologies Division Specifications — (continued) Under normal conditions, light transmitted by the LED The FirePrint technology for Model FP-11 monitors is directed away from the photodiode and scattered input from the photo chamber and the thermal sensor, through the smoke chamber in a controlled pattern. evaluating this information with sophisticated The smoke chamber is designed to manage light mathematical formulas or algorithms,and compares dissipation and extraneous reflections from dust data transfer to this input to the characteristics of both particles or other non-smoke airborne contaminants in threatening fires and deceptive phenomena that would such a way as to maintain stable,consistent detector deceive any ordinary detector. operation. When smoke enters the detector chamber, This technology was developed over years of research light emitted from the IRLED is scattered by the smoke and reviewing the results of over 20 years of fire-test particles,and is received by the photodiode. data in one of the world's most advanced fire research Model FP-11 also utilizes a modern,accurate and centers. The results of this research are the shock-resistant thermistor to sense temperature mathematical models that form the algorithms used in changes. The'on-board'FirePrint technology FirePrint. No other fire detector has this level of allows the detector to gather smoke and thermal data, intelligence or,this amount of research and analyzing this data in the detector's'neural network.' development supporting its design. By comparing data received with the common The software of the microprocessor can identify and characteristics of fires,or fire fingerprints, Model FP-11 disregard false input caused by radio frequency(RFI) can compare these'fire prints'to those of deceptive and electromagnetic(EMI) interference,and validates phenomena that cause other detectors to go into Alarm all Trouble conditions before annunciating or reporting mode, to the control panel. The microprocessor for Model FP- This advanced FirePrint technology allows Model FP-11 11 uses an integral electronically erasable to accurately determine a true fire hazard from non- programmable read-only memory(EEPROM)to store threatening,deceptive phenomena—without the need the detector's address and other critical operating to use alarm-delaying verification and confirmation parameters,which include the assigned program techniques;thus decreasing the probability of losses in values for Alarm and Trouble—command thresholds. infrastructure from an actual fire. Communications within the detector;between Model Model FP-11 provides the highest level of detector FP-11 and the FACP,or with the field programmer 1 intelligence available today with a detector 1 control- tester(Model DRU 1 FPI 32),are supervised and panel link that allows the user to program the detector safeguarded against disruption by reliable, for the specific hazard profile. microprocessor-based error checking routines. Detectors are optimized by selecting one(1)of Additionally,the microprocessor supervises all EEPROM memory locations and provides a high degree of the following applications: EEPROM failure fault tolerance. • Office 1 Retail Model FP-11 determines its operating status(Normal, • Lobby • Computer room Alarm,or Trouble modes)based upon the difference • Dormitory between the alarm-threshold values stored in the • Healthcare facility detector's memory and the detector's latest analog • Parking garage measurement. The detector then communicates • Utility/transformer room changes in its status to the FACP. • Hostile environment In addition,the FACP will sample the value of the • Precious storage analog signal for Model FP-11 over a period of time,in •Air duct •Warehouse 1 light manufacturing order to determine if those values indicate excessive buildup in the photo chamber. In the event of Once programmed,the software does the rest— excessive buildup,the FACP will accurately indicate no guessing on detector sensitivities or alarm which detector shall require maintenance. verification—the FACP programs Model FP-11 for the Model FP 11 is listed as a self testing device. The LED protected area without any confirmation delays. for Model FP-11 flashes green every four(4)seconds, Once optimized for the hazards in the protected area, indicating communication with the FACP,and that it Model FP-11 provides the utmost means in detection. has passed its self-test. Should the detector sense a Should the operator or installer forget fault or failure within its systems,the LED will flash to program the detector, Model FP-11 will revert amber,and the detector will transmit that data to the to a default setting that, in turn,allows operation FACP. A quick visual inspection is sufficient to indicate as a standard photoelectric or photothermal detector. the condition of the detector at any time. SIEMENS Industry, Inc. Building Technologies Division Specifications — (continued) If more detailed information is required,a printed Model FP-11 uses the low-profile,surface-mounting report can be provided from the FACP,indicating the base, Model DB-11. This base mounts on a 4-inch status and settings assigned to each individual octagon,square,or a single-gang electrical box. The detector. base utilizes screw-clamp contacts for electrical When Model FP-1 lactivates into Alarm mode,the connections and self-wiping contacts for increased detector will flash amber,and will transmit that data to reliability. the FACP. When the FACP confirms the condition of The base can be used with the optional Model LK-11 the detector,the FACP will instruct Model FP-11 to detector locking kit,which contains 50 detector locks, flash red—and continue to flash red—until the system as well as an installation tool,thus preventing is reset manually at the FACP. At that same time,any unauthorized removal of the detector head. Model DB- user-defined system alarm functions programmed into 11 has integral,decorative plugs to cover the outer the system are activated. Each Model FP-11 detector mounting screw holes. can operate one(1) remote alarm indicator;one(1) Model FP-11 is electrically compatible with existing auxiliary relay,or one(1)audible base. MXL-detector accessories,including relays, remote Detector sensitivity,calibration and identification are lamps,duct housings and audible bases. With duct dynamically supervised by the FACP. Detector housings,a base adapter and new detector housing sensitivity and pre-Alarm levels are a function of the cover are required (order AD-11 UK upgrade kit). To use application chosen at the FACP,and are controlled by existing Model DB-3S base or audible base, Model FP- the panel. If an alternate, non-FirePrint mode is 11 requires a base adapter(Model DB-ADPT). selected,then the sensitivity can be changed from the FACP. Temperature and Humidity Range The Program/Test unit(Model DPU or FPI-32) upgrade All Model FP 11 detectors are t9UL 864 9th Edition kit is used to program and verify the detector's address. Listed for indoor dry locations within a temperature The technician selects the accessory's program mode to range of 120+/-3°F(49+1-2°C)to 32+/-3°F(0+/-2°C)and enter the desired address. In turn,the programmer a relative-humidity range of 93+1-2%at a temperature unit(Model DPU or FPI-32)automatically sets/verifies of 90+/-3°F(32+/-2°C). the address,and tests the detector. Model DPU 1 FPI-32 Application Data also allows the user to change the device ID from that Installation of the Model FP-11 series of fire detectors of a Model FP-11 detector to an older detector ID(such requires a (2)two-wire circuit of 18 American Wire as: ILP-1,ILPT-1,ILP-2,ID-60P or ID-60PT)to allow for Gauge(AWG),minimum,thermoplastic fixture wire easy replacement of older detectors without the need enclosed in conduit,or 18 AWG(American Wire Gauge) of reprogramming the FACP. limited-energy,shielded-cable without conduit,if The FPI-32 upgrade kit operates on AC power or permitted by local codes. Field wiring should conform rechargeable batteries, providing flexibility and to local and national electric codes and the control convenience in programming and testing equipment panel wiring specifications. from almost any location. When in'test'mode, Model 'T-tapping'is permitted only for Style 4(Class B)wiring. DPU or FPI-32 upgrade kit will perform a series of diagnostic tests without altering the address or other Model FP 11 fire detectors can be applied within the stored data,allowing technicians to determine if the maximum 30-foot center spacing (900 sq.ft.areas),as detector is operating properly. referenced in NFPA 72. This applications guideline is based upon ideal conditions—specifically—smooth Model FP-11 may be installed on the same initiating ceiling surfaces, minimal air movement,and no circuit with Models IL or ID series detectors physical obstructions between potential fire sources (Photoelectric,thermal,or ionization);Model MSI- and the detector. Do not mount detectors in close series manual stations;Model TRI-series interfaces; proximity to ventilation or heating and air-conditioning Model ICP output-control devices,or Model CZM series outlets. of addressable,conventional zone modules. Exposed joints or beamed ceilings may also affect safe All Model FP-11 detectors can be cleaned in the field— spacing limitations for detectors.Should questions when required—by simply removing the detector cover arise regarding detector placement,observe National and unsnapping the photo chamber. There is also the Fire Protection Association (NFPA)72 guidelines. option of cleaning the interior of the detector with a clean,soft cloth or brush,or replacing the labyrinth and bug screen included in the detector maintenance kit, Model DMK-11. SIEMENS Industry,Inc. Building Technologies Division Technical Data Details for Ordering Environmental 'Mel Part `" t ,* Temperature: 32°F(TO to 100°F(38°C) ., _ er NU ,y, ; Descri `�`= i` Humidity: Up to 93%RH,non-condensing FP-11 500-095112 Addressable FirePrintm"Detector Air Pressure: No effect DB-11 500-094151 Detector Mounting Base Alarm Temperature: 135°F(57°C) For Series 11 Intelligent Detectors DB-11E 500-094151E Detector Base(Small) Electrical Air-Duct Housing Voltage: 16—27 VDC AD2-P 500-649706 (for use with Models FP-11,HFP-11, HFPO-11 and PE-11 Detectors) Ripple: 3V,peak-to-peak Supervisory Current: 11 ONA max ____Air-Duct Housing______ Alarm Current: 33—SomA AD2-XHR 500-649708 (for use with Models FP-11,HFP-11, HFPO-11 Detectors with Relay) ADBX-11 500-096181 Audible Base Dimensions DB-X11 RS 500-096125 Relay Base for Model 11 series Intelligent Detectors Diameter Base Remote Alarm Indicator 0 g•' RLI-1 500-390673 i 4"Octagon Box Mount,Red 1 05.3 cm] RLI-2 500-390674 Remote Alarm Indicator ir "^ Single-Gang Mount,Red �,11111"— �- DMK-11 500-695338 Model 11-series Maintenance Kit �_ "' .� (replacement labyrinth and bug screen) Height DB-ADPT , 500-094187 Base Adapter to Model DB-3S Base •3"• _\ j_ ..,. LK-11 500-695350 Base Locking Kit for Series 11 Detectors [5.8cm] 1/00.r.7171., ' �' In Canada,please order: ; Description 135°F Fixed Temperature,Plug-In FP-11C 500-095112C Detector Addressable FirePrint'^^ Detector]@ULC Listed] Detector Mounting Base DB-11C 500-095687 (for Model 11-series Intelligent Detectors) , ]@ULC Listed] AD-11 PC 500-095984 Air-Duct Housing[ ULC Listed] DB-X11 RSC 500-093125C Relay Base for Model 11-series Intelligent Detectors[ 'ULC Listed] ADBX 11 C 500-096181C Audible Base for Model 11-series Intelligent Detectors(4"AULC Listed] Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information,refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario June 2012 Building Technologies Division Tel:(973)593-2600 SII-FS L6T 5E4/Canada Supersedes sheet dated 8/10 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (Rey.2) URL:www.usa.Siemens.com/Fire FAX:(905)799-9858 1 !Data Sheet LSpecialized Devices is Air-Duct Housings (FDBZ Series) ; Models FDBZ492, FDBZ492-HR, FDBZ492-R and FDBZ492-RP {with FDBZ-WT and FDBZ492-RTL} ' ARCHITECT AND ENGINEER SPECIFICATIONS __ • Four (4) models available . _ • Addressable and conventional with and without relays ' , 441 • Compatible with Siemens—Fire Safety conventional 4y -w ' fiand addressable fire-alarm control panels(FACPs) : • Magnet test feature with the Model OP121 FDBZ-series of air-duct housings r-31 [FDBZ492,FDBZ492-HR,FDBZ492-R&FDBZ492-RP] tsx conventional detector =, Remote alarm - • Design for air-velocity range of 100 indicator to 4,000 feet-per-minute (fpm) [FDBZ492-RTL] • Robust,compatible conventional remote indicator test switch that incorporates tri-color light-emitting diode (LED) - • Clear housing cover with smoke test port on cover t for quick identification of detector type - • Removable via four(4)captive-thumb screws(no tools required) ht housin • Includes a smoke/aerosol detector test port Watertight 9 [FDBZ-WT] ,:l; • Optional NEMA 4X-reinforced, stainless-steel and • Self-contained model available with 'on board' ,, watertight enclosure available, Model FDBZ-WT power supply for conventional detectors • No tools required for cover removal, sampling and • Expanded temperature range 4 i' exhaust-tube installations • Relay models available • Trouble-event activation upon front-cover removal • ®UL268A Listed,®ULC S529 Listed; lig ; • Alarm LED visible from front FM (#3010), CSFM (#3240-0067:0265) Approved Product Overview The Siemens—Fire Safety Model'FDBZ'-series of air- Notes-(cont.'d): With either the Cerberus PRO series or duct-detector housings are designed for use with FireFinder XLS series of FACPs,up to 252-addressable (`;• detectors with relays per circuit may be used.The connection of an Siemens Model'H'series,Cerberus PRO series and intelligent remote lamp(ICED)and a remote relay is allowed for Model OP121 detectors. (see: Details for Ordering for each detector simultaneously. a complete list of compatible devices). Designed for installation directly to heating,ventilating Specifications , ' and air-conditioning (HVAC)duct systems,the Model The Model'FDBZ'-series of air-duct housings are uniquely �:.: 'FDBZ'-series of duct housings complies with National designed to use with the photoelectric detector. Sensitivity $ Fire Protection Association Standard (NFPA) No.'s 72 of Models PE-11,PE-11C,OP121,and 8854 conventional and 90A,and is Underwriters'Laboratories Listed. detectors can be verified for calibration via LED visual status When equipped,the air-duct detector housing will or a Model RSAW-11, Model RSAC-11 or FDBZ492-RTL multi- color remote lamp. A green flash indicates the detector has , signal the presence of smoke being carried through passed its self test. Amber indicates a Trouble condition,and the duct system. Air-duct detectors are not intended y red indicates an Alarm event. to be substituted for open-area detection. .; Notes: Most conventional time-control equipment guarantee Sensitivity for Models FP 11,HFP 11,SFP 11,H FPO 11, only one(1)detector per zone when the detector's SFPO 11,OP921,OOH941,OOHC941,8710,and 8713 operated relay function is critical. The connection of a intelligent detectors is verified from the multi-color LED of remote lamp and a remote relay—per detector— is the respective detector,or its sensitivity reading may be allowed. Refer to the installation manual of the rented bycommand fromthe corresponding FACP to an respective conventional FACP. p pong JR optional printer. - Cerberus® PRO 9906 ,. -S.',.&11.6': . ,...i114:44,Ii< Fire Safety Products Model 'FDBZ' Series of Air-Duct Housings and Detectors Answers for infrastructure SIEMENS lie Specifications — (continued) Sampling Tube Selection Table The remote alarm indicator(Model FDBZ492-RTL)allows for Duct Width Sampling Tube manual testing via a key-switch for conventional and (Model No.) addressable detectors,as well as the conventional and For duct widths 6"to 1' ST-10 addressable air-duct housing with relay. Model FDBZ492- For duct widths 1'to 3' ST-25 RTL,which mounts remotely from the conventional and For duct widths 3'to 5' ST-50 addressable air-duct housing,allows for manual relay- (requires support) output control. The duct-detector remote indicator key- For duct widths 5'to 10' ST-100 switch also indicates the current state of the detector. (requires support) The watertight housing (Model FDBZ-WT),which allows the Maintenance of the detector is easily accomplished via the air-duct detector housing to be installed inside the separate removal of the duct-housing sampling chamber cover. The NEMA 4X enclosure, is for installations for either an outdoor detector,which plugs into the housing,is easily removed area or in environments where excessive moisture is for cleaning or replacing by a trained technician. prevalent. All that is necessary for installation of the air-duct detector Each detector unit employs a cross-sectional sampling is the cutting of three(3)small holes for the Sampling Tube principle of operation. Inlet sampling tubes are installation(template included),and the drilling of two(2) available in four(4) lengths(see: Sampling Tube holes for mounting the air-duct housing. The unit is then Selection Table). Outlet sampling tubes are one(1) easily mounted in place,and connection made to the common length and draw. A continuous,cross-sectional existing wires or terminals—if optional accessories are sample of air moves through the duct. Stratification or skin utilized. No mechanical tools are required for removing the affect phenomenon that occurs in the duct can prevent cover or connecting the sampling and exhaust tubes to an smoke(especially in large ducts)from reaching a spot-type air-duct housing. detector. Models ST-50 and ST-100 require support. However, Model In addition,the unique design of the sampling chamber ST-100 is shipped in two(2) 5-ft. (152 cm.) pieces with a insures uniform sensitivity in air velocities, ranging from a coupling for field assembly. low of 100 fpm to as high as 4,000 fpm. Each air-duct housing comes with three(3)wiring entry ports: Technical Data ■ Two(2) 3/4"conduit knockouts Operating • One(1)1/2"conduit opening p g Temperature +32°F (0°C)to 120°F (49°C) The inlet sampling tube length is determined by the width Ranges: of the air duct being protected. The inlet tube—greater than and nearest to the duct width—should be used (see: Sampling Tube Pressure > 0.01 inches; Sampling Tube Selection Table).The inlet tube can then be Range of Differences: < 1.2 inches of water trimmed at the job site to the exact width of the duct.The column outlet sampling tube for all ducts—irrespective of width— has a fixed length of approximately 5.5 inches(14cm.),and Relative Humidity: 0—95%; non-condensing is supplied with the air-duct housing. Air Pressure/ No effect/ Note: When the use of a remote relay is required,order Altitude Range: No limitations Model FDBZ492-R for conventional systems;Model FDBZ492-HR for addressable systems.When required, Air-Duct Velocity: 100—4,000 ft./min a separate watertight enclosure(Model FDBZ-WT), (0.51—20m/sec) which is designed to contain the air-duct housings is available. Dimensions: {H-x-W-x-D} (For full details,refer to installation instructions for the •Rectangular: 14.38"-x-5"-x-2.5" respective air-duct housing.) (37 cm.-x-12.7 cm.-x-6.36 cm.) Note: When a self-contained duct detector with power ■Square: 7.75"-x-9"-x-2.5" supply is required,order Model FDBZ492-RP. (19.7 cm.-x-22.9 cm.-x-6.36 cm.) (For full details,refer to installation instructions part Detector Weight: 1.8 Lbs.(0.82 Kg.) number A6V10330327.) SIEMENS Industry, Inc. Cerberus® PRO Building Technologies Division Operation Details for Ordering Based on the monitoring results,the LED indicator flashes Part Model Description the following colors based on the following conditions: Number a, Flash A two-wire addressable or conventional FI sh duct detector(without relays)designed for Cond ition Interval direct use on heating,ventilating and air- Color conditioning(HVAC)air-duct systems. (in seconds) When equipped,the air-duct detector Normal supervisory operation. S5431 9-B22- housing will signal the presence of smoke FDBZ492 Al being carried through the duct system. Green*: Smoke sensitivity is within 10 rated limits. For use with the following Models: - 8710 —8713 —0011941 —OP121 Detector is in Trouble - 8854 —HFPO-11 —00HC941 —PE-11 Yellow: condition, and needs either 4 - FP-11 —HFP-11 —PE-11C —SFP-11 repair or replacement. -srPo-11 A two-wire addressable duct detector(with Red: Alarm condition. 1 relays)designed for direct use to HVAC air- duct systems and works with the Remote No Flash: Detector is not powered. -- Test Switch(FDBZ492-RTL). This part has a programmable relay base,and when *LED can be turned OFF. equipped,the addressable air-duct detector Please follow the corresponding description of the panel used. FDBZ492- 554319-B23- housing will signal the presence of smoke being carried through the duct system. HR Al For use with the following Models: — 8710 — FP-11 — 8713 — HFP-11 Products included with the air-duct housing: - 00H941 — HFPO-11 (1)short-return(outlet)tube — 00HC941 — OP921 - (1)stopper — SFP-11 — SFPO-11 A two-wire conventional duct detector with - (2)#12+3/4"sheet-metal screws relays designed for direct use on HVAC air- - (1)mounting template duct systems. This detector has a relay base,and when equipped with conventional Note: Detector and sampling tube to be purchased separately. S54319-B24- air-duct housing,will signal the presence of Minimum hardware required is: one(1)air-duct housing FDBZ492-R Al smoke being carried through the duct assembly;one(1)sampling tube and one(1)detector. system. For use with the following Models: — PE-11 —PE-11C — OP121 —8854 A four-wire conventional duct detector with relays and a built-in power supply. Housing is designed for direct use to HVAC air-duct systems. It has a relay base with a built-in power source. When equipped with FDBZ492- S54319-B25- conventional air-duct housing,this duct RP Al detector will signal the presence of smoke being carried through the duct system. For use with the following Models: — PE-11 —PE-11C - OP121 Device is used for manual testing via a key- switch for duct-housing Models FDBZ492-R, FDBZ492-RP and FDBZ492-HR. Device mounts remotely from the conventional and FDBZ492- 554319-S27- addressable air-duct housing,allowing for RTL Al manual relay-output control. The duct- detector remote key-switch also indicates the current state of the detector. For use with the following Models: —FDBZ492-HR •FDBZ492-R •FDBZ492-RP An optional,separate watertight NEMA 4X enclosure(Model FDBZ-WT)that provides added watertight protection for any of the Model FDBZ492-series duct housings.The duct housing fits into the separate 4X enclosure. This part allows the air-duct FDBZ-WT S54319-B26- detector housing to be installed in the Al separate enclosure,and can be used in either an outdoor area or in environments where excessive moisture is prevalent. For use with the following Models: — FDBZ492 — FDBZ492-R — FDBZ492-HR — FDBZ492-RP ST-10 500-649710 Sampling tube for Ducts 6"to 1' ST-25 500-649711 Sampling tube for Ducts over 1'to 3' ST-50 500-649712 Sampling tube for Ducts 3"to 5' ST-100 500-649713 Sampling tube for Ducts 5'to 10' SIEMENS Industry, Inc. Cerberus® PRO Building Technologies Division SIEM ENS Cerberus® PRO NOTICE—The information contained in this data-sheet document is intended only as a summary,and is subject to change without notice. The devices described here have specific instruction sheets that cover various technical,limitation and liability information. Siemens Industry, Inc.—Building Technologies Div. Copies of these instruction sheets and the General Product Warning and Limitations document, 8 Fernwood Road • Florham Park, NJ 07932 which also contains important information,are provided with the product and,are available from Tel: (973) 593-2600 • Fax: (908) 547-6877 the Manufacturer. Web:www.USA.Siemens.com/Cerberus-PRO Information contained in these documents should be consulted before specifying or using the product. For further information or assistance concerning particular problems contact the Manufacturer. Building Technologies Division September 2014—Supersedes sheet dated 8/2013 SII–Fire Safety (Rev.4) [Printed in U.S.A « » • \22 \ • or t �\ • 3«� VV.; 114- k- «. {\\it ) 3<: ) ��§ t\? ) �\ \ t< . ��) IV/ FAPS-F1 SIEMENS BATTERY&VOLTAGE DROP CALCULATIONS FIRE ALARM SUBMITTAL Washington Square Lucky Brand FAPS-FI SPECIFICATIONS FAPS-F1 BATTERY CALCULATIONS FAPS-Ft PANEL 24 Hours(A)Requirement for Standby Charge: PS-8 MODEL 15 Minutes(B)Requirement for Alarm Charge: 15%Design Voltage Drop(20%Max Voltage Drop) 20%(C)Spare Battery Capacity: 3.00 Amp Max Current Draw Per Output 0.13 Amp(F)Standby Total Current Draw 2.50 Amp Max Current Draw Per AUX Output 3.42 Amp(G)Alarm Total Current Draw 8.00 Amp Max Current Draw Per Panel 3.1 Amp Hr(H)Design Standby Charge=(A x F) 14 AWG Wire Gauge 0.9 Amp Hr(J)Design Alarm Charge=(B x G)I60 20.4 VDC Voltage at First Device' 0.8 Amp Hr(K)Additional Capacity Charge=(C x((A x F)+(B x G)/60)) 0.13 Amp Standby Current Draw 4.7 Amp Hr(AH)Battery Amp Hour requirement=(H+J+K) 0.13 Amp Alarm Current Draw 7.0 Amp Hr Battery Size 32.0 Amp Hr Max Battery Charging Capacity FAPS-F1 VOLTAGE DROP CALCULATION RESULTS PERCENT STANDBY ALARM PERCENT OUTPUT VOLTAGE CURRENT CURRENT CURRENT LABEL Lucky Brand DROP DRAW DRAW DRAW OUTPUT-1 NF1-1- 2.69 Volt 13.20% 0.00 Amp 1.49 Amp 49.77% OUTPUT-2 NF1-2- 1.05 Volt 5.14% 0.00 Amp 0.78 Amp 25.90% OUTPUT-3 NF1-3- 1.62 Volt 7.94% 0.00 Amp 1.02 Amp 34.03% OUTPUT-4 NF1-4- 0.00 Volt 0.00% 0.00 Amp 0.00 Amp 0.00% AUX OUTPUT NF1-AX- 0.00 Volt 0.00% 0.00 Amp 0.00 Amp 0.00% Total Current Draw 0.00 Amp 3.29 Amp 41.14% FAPS-F1 VOLTAGE DROP CALCULATIONS LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE' Alarm Voltage Drop=VD=R x la FAPS-Fl PS-8 = - 7,i'.' __20A00 287.25 Ft (L)Total Circuit Length(One Leg) NF1-1-01 75cd E60H-24MCC-FW 0.189 35.92 ft 20.383 3.14 Ohm Wire Resistance Per 1000 Feet NF1-1-02 75cd E60H-24MCC-FW 0.189 31.42 ft 20.252 1.80 Ohm (R)Total Circuit Resistance(Both Legs) NF1-1-03 75cd E60H-24MCC-FW 0.189 31.25 ft 20.131 0.00 Amp (Is)Total Current Draw(Standby) NF1-1-04 15cd E60H-24MCC-FW 0.065 28.92 ft 20.055 1.49 Amp (la)Total Current Draw(Alarm) NF1-1-05 30cd E60H-24MCC-FW 0.105 20.50 ft 20.015 17.71 Volt (20.4-(lax R))Applied Voltage at Last Device' NF1-1-06 75cd E60H-24MCC-FW 0.189 41.17 ft 19.923 2.69 Volt (VD)Voltage Drop NF1-1-07 75cd E60H-24MCC-FW 0.189 21.67 ft 19.802 13.20% Percent Voltage Drop NF1-1-08 75cd E60H-24MCC-FW 0.189 41.42 ft 19.681 49.77% Percent Current Draw Output-1 NF1-1-09 75cd E60H-24MCC-FW 0.189 35.00 ft 19.528 OUTPUT-2 LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE' Voltage Drop=VD=L'R'la FAPS-Fl - 'PS-8 Jr' 20.400 214.83 Ft (L)Total Circuit Length(One Leg) NF1-2-01 15cd STWC 0.061 42.25 0 20.396 3.14 Ohm Wire Resistance Per 1000 Feet NF1-2-02 15cd STWC 0.061 7.83 ft 20.358 1.35 Ohm (R)Total Circuit Resistance(Both Legs) NF1-2-03 15cd E60H-24MCC-FW 0.065 16.42 ft 20.343 0.00 Amp (Is)Total Current Draw(Standby) NF1-2-04 15cd STWC 0.061 10.17 ft 20.327 0.78 Amp (la)Total Current Draw(Alarm) NF1-2-05 30cd E601-1-24MCC-FW 0.105 29.00 ft 20.292 19.35 Volt (20.4-(la x R))Applied Voltage at Last Device' NF1-2-06 30cd E60H-24MCC-FW 0.105 27.92 ft 20.233 1.05 Volt (VD)Voltage Drop NF1-2-07 75cd E60H-24MCC-FW 0.189 30.58 ft 20.147 5.14% Percent Voltage Drop NF1-2-08 15cd E60H-24MCC-FW 0.065 27.25 ft 20.074 25.90% Percent Current Draw Output-2 NF1-2-09 15cd E60H-24MCC-FW 0.065 23.42 ft 20.043 PROPRIETARY DOCUMENT FOR APPROVAL ONLY 91612018 FAPS-FI VOLTAGE DROP CALCULATIONS CONTINUED Mink MIGIESSIZIESI= OUTPUT-3 LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE' Voltage Drop=VD=L'R'la FAPS-F1 PS-8 o g -T 20.400 252.67 Ft (1)Total Circuit Length(One Leg) NF1-3-01 15cd E60H-24MCC-FW 0.065 27.50 ft 20.397 3.14 Ohm Wire Resistance Per 1000 Feet NF1-3-02 30cd E60H-24MCC-FW 0.105 35.83 ft 20.342 1.59 Ohm (R)Total Circuit Resistance(Both Legs) NF1-3-03 30cd E60H-24MCC-FW 0.105 32.92 ft 20.268 0.00 Amp (Is)Total Current Draw(Standby) NF1-3-04 75cd E60H-24MCC-FW 0.189 42.25 ft 20.151 1.02 Amp (la)Total Current Draw(Alarm) NF1-3-05 75cd E60H-24MCC-FW 0.189 33.92 ft 19.999 18.78 Volt (20.4-(lax R))Applied Voltage at Last Device' NF1-3-06 15cd E60H-24MCC-FW 0.065 28.33 ft 19.918 1.62 Volt (VD)Voltage Drop NF1-3-07 15cd STW 0.057 13.58 ft 19.895 7.94% Percent Voltage Drop NF1-3-08 15cd STW 0.057 19.58 5 19.880 34.03% Percent Current Draw Output-3 NF1-3-09 75cd E60H-24MCC-FW 0.189 18.75 5 19.840 OUTPUT-4 LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE' Voltage Drop=VD=L'R'la FAPS-F1 „PS-8 b4[ 1 20.400 0.00 Ft (L)Total Circuit Length(One Leg) 3.14 Ohm Wire Resistance Per 1000 Feet 0.00 Ohm (R)Total Circuit Resistance(Both Legs) 0.00 Amp (Is)Total Current Draw(Standby) 0.00 Amp (la)Total Current Draw(Alarm) 20.40 Volt (20.4-(la x R))Applied Voltage at Last Device' 0.00 Volt (VD)Voltage Drop 0.00% Percent Voltage Drop 0.00% Percent Current Draw Output-4 AUX OUTPUT LABEL CD MODEL STANDBY ALARM DISTANCE VOLTAGE' Voltage Drop=VO=L'R'la FAPS-FI 5-i PS-8 _ = t 4/7 L 20.400 0.00 Ft (L)Total Circuit Length(One Leg) 3.14 Ohm Wire Resistance Per 1000 Feet 0.00 Ohm (R)Total Circuit Resistance(Both Legs) 0.00 Amp (Is)Total Current Draw(Standby) 0.00 Amp (la)Total Current Draw(Alarm) 20.40 Volt (20.4-(la x R))Applied Voltage at Last Device' 0.00 Volt (VD)Voltage Drop 0.00% Percent Voltage Drop 0.00% Percent Current Draw Aux Output Note-1;24 Volt derated by 15%to 20.4 Volts. Note-2;Point to Point Voltage Drop Calculation. Note-3;Line Voltage Drop Calculation PROPRIETARY DOCUMENT FOR APPROVAL ONLY 9/6/2018 db LOSS CALCULATIONS SIEMENS FIRE ALARM SUBMITTAL Washington Square Lucky Brand FAAB-F7 PANEL EBA2001 AMP MODEL 0.50 dB Mao dB Loss 50 Watt Max Wattage Per Output 100 Watt Max Wattage Per Card 14AWG Wire Gauge 70 VRMS (V)Audio Voltage db LOSS CALCULATION RESULTS OUTPUT TOTAL PERCENT LABEL db LOSS WATTS OUTPUT LOAD OUTPUT 1 SF1-1- -0.04 dB 7.00 Watts 14.00% OUTPUT 2 571-2- -0.01 dB 3.50 Watts 7.00% OUTPUT3 SPARE #DIV/01 0.00 Watts 0.00% OUTPUT 4 SPARE #DIV/OI 0.00 Watts 0.00% Total Watts 10.50 Watts 10.50% OUTPUT 1 db LOSS CALCULATIONS LABEL WATT MODEL db LOSS db Loss=20log10(RL/(RL+RW() FAAB-Fl EDA2001112PV' _„�-� �Al2 SF1-1-01 1/4W E60H-24MCC-FW .000 dB 70 VRMS (V)Audio Voltage SF1-1-02 1/2W E60H-24MCC-FW .001 dB 0.0031 Ohm (R)Wire Resistance Per Foot SF1-1-03 1W E60H-W .002 dB 561.17 Ft (L)Total Circuit Length(One Leg) SF1-1-04 1/2W E600-24MCC-FW 003 dB 700.00 (RL(Load Resistance=1/"2AN SF1-1-05 1/2W 44op-246074 005 dB 3.48 Ohm (RW)Circuit Resistance=R*L'2(Both Legs) SF1-1-06 1W E60H-24MCC-FW .007 dB 7.00 Watt (W)Total Circuit Wattage SF1-1-07 12W E6019-24MCC-FW .009 dB -0.04 dB Total Circuit Signal Loss SF1-1-08 1/4W E60H-24MCC-FW .011 dB dB Loss=20log10(RLgRL+RW() SF1-1-09 1/4W E60H-24MCC-FW .013 dB 14.00% Percent Output Load SF1-1-10 114W E60H-24MCC-FW .015 dB 5F1-1-11 1/4W E60H-24MCC-FW .017 dB SF1-1-12 1/4W E60H-24MCC-FW .020 dB SF1-1-13 1/4W E60H-W .022 dB SF1-1-14 1/4W E60H-W .025 dB 5F1-1-15 1/4W E605-24MCC-FW .028 dB SF1-1-16 1/4W E60H-24MCC-FW .031 dB SF1-1-17 1/4W E60H-24MCC-FW .034 dB SF1-1-18 1/4W E60H-24MCC-FW .037 dB PROPRIETARY DOCUMENT FOR APPROVAL ONLY 9/6/2018 OUTPUT 2 db LOSS CALCULATIONS LABEL WATT MODEL db LOSS db Loss=20Iog10(RL/(RL+RW)) FAAB-Fl a EhA2001 :MOVE' _ ,, ,, z SF1-2-01 1/2W E60H-24MCC-FW .000 dB 70 VR MS (V)Audio Voltage SF1-2-02 1/2W E60H-24MCC-FW .001 dB 0.0031 Ohm (R)Wire Resistance Per Foot SF1-2-03 1/2W E60H-24MCC-FW 001 dB 236.17 Ft (L)Total Circuit Length(One Leg) SF1-2-04 1/2W E60H-24MCC-FW 003 dB 1400.00 (RL)Load Resistance=V"2AN SF7-2.05 1/2W E601-1-24MCC-FW .004 dB 1.46 Ohm (RW)Circuit Resistance=R*L*2(Both Legs) SF7-2-06 1/2W E60H-24MCC-FW 005 dB 3.50 Watt (W)Total Circuit Wattage SF1-2-07 1/2W E60H-24MCC-FW 007 dB -0.01 dB Total Circuit Signal Loss dB Loss=20Iog10(RL/(RL+RW)) 7.00% Percent Output Load OUTPUT 3 db LOSS CALCULATIONS LABEL WATT MODEL db LOSS db Loss=20Iog10(RL/(RL+RW)) FAAB-F1 ^EBA2001 SPARE01 70 VR MS (V)Audio Voltage 0.0031 Ohm (R)Wire Resistance Per Foot 0.00 Ft (LI Total Circuit Length(One Leg) #DIV/0! (RL)Load Resistance=V"2AN 0.00 Ohm (RW)Circuit Resistance=R'L*2(Both Legs) 0.00 Watt (W)Total Circuit Wattage #DIV/01 Total Circuit Signal Loss d8 Loss=201og10(RL/(RL+RW)) 0.90% Percent Output Load PROPRIETARY DOCUMENT FOR APPROVAL ONLY 9/6/2018