Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (86)
.Sa - &\\ t-31 S5-A- Si,),> 1'u 1r N - Fire Protection Services, Inc. 9950 SW Arctic Dr , -,.4.4L,...0' Beaverton Or,97005 ' i> x. Phone: (503) 590-3732 1 Fax: (503) 628-6214 -° . r-9 Vj River Terrace East Condos 13187 SW 169th Avenue RECEIVED Sherwood, Oregon 97140 SEP ) 2018 FIRE ALARM DESCRIPTION CITY OF TIGARD BUII�.1D NG DIVISION DESCRIPTION An automatic fire protection system will be installed utilizing an addressable control panel. This will provide for monitoring of sprinkler control valves, flow switches, a single Pull station in the riser room, and an annunciator keypad at the main entrance. The interior room LF horns will be mounted at 84"to the bottom of the device or on the ceiling. The pull station will be mounted at 48"to the center of the device. All audible devices will sound in the ANSI temporal pattern. Primary power to the panel shall be 110 VAC utility power with a 12VDC 7aH battery back-up. All fire alarm circuits will be wired with 16 gauge Fire Alarm Cable with the exception of NAC circuits, which will be wired with (minimum) 14 gauge Fire Alarm Cable. Monitoring will be provided through Alarm Central Station, A UL Listed Monitoring Company in Beaverton, OR. (503.641.6761) All installation will be done according to NFPA 70 &72 standards. Work will be performed in a neat and professional manner. All work will be performed according to the timeline set. All equipment will be UL listed and approved for the application. SYSTEM COMPONENTS Silent Knight 5820x1 Addressable Fire Alarm Control &Communicator Silent Knight SK Series Smoke Detectors and Heat Detectors i; Potter PSN 106 Distributed Power Supplies Silent Knight Addressable Relay Modules 1 System Sensor Horn Strobes/ Strobes System Sensor LF Horns j i 1 is 'k v t. _ Global Project Values: ftSILENT Project Name: River Terrace East Condos Standby Hours: 24 KNIGHT Project ID: Alarm Mins: 5 Prepared By: D Phipps Derating Factor: 1.2 1 5820XL Calculations Date: 8/29/2018 Voltage Drop Warning Version 12.30.10 Threshold%: 10 Panel ID:15820XL Model: 5820XL Add.Fire Alarm Control Panel Max NAC Current: 3.0 Amps Location: FLOOR 1 ELEC ROOM Volts: 24 VDC Max Panel Current: 6.0 Amps iT Ckt.# Circuit Name Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm &Type 1000 Ft. One-Way Ohms EOL 5820XL 5820XL CTRL Panel 0.215 0.385 SK Photo,Photo-T 5 0.001 0.001 SK Ion 0.000 0.000 SK Heat,Heat-HT 1 0.000 0.000 SK Heat ROR 0.000 0.000 SK Beam,Beam-T 0.000 0.000 SK Duct 0.000 0.000 , SK Acclimate 0.000 0.000 SK Control 0.000 0.000 SK Control-6 0.000 0.000 M; SK Relaymon 0.000 0.000 J. SK Monitor,Minimon 5 0.002 0.002 SK Monitor-2 4 0.003 0.003 SK Monitor-10 0.000 0.000 SK Pull-SA,Pull-DA 2 0.001 0.001 SK Relay 5 0.001 0.001 SK Relay-6 0.000 0.000 l SK Zone 0.000 0.000 SK Zone-6 0.000 0.000 0' SK Isolator Module 0.000 0.000 4 SSB224BI Isolator Base 0.000 0.000 I B200SR Sounder Base 0.000 0.000 SSB224RB Relay Base 0.000 0.000 SSRTS151 Magnetic Remote Test 0.000 0.000 i' SSRTS151 KEYKey Activated Test t 0.000 0.000 SSRA100Z Remote LED 0.000 0.000 5815XL SLC Loop Expander 0.000 0.000 5860 • LCD Remote Annunc 1 0.020 0.025 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 5865-4 LED Annunciator(4G) 0.000 0.000 1`: 5865-3 LED Annunciator(3G) 0.000 0.000 II' 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 PGM-I/O#1 Notification Appl Circuit 0.000 0.705 #14 Solid 2.52 132 0.67 19.93 2.30% r` PGM-I/O#2 Notification Appl Circuit 0.000 1.296 #14 Solid 2.52 165 0.83 19.32 5.28% `1 PGM-1/0#3 Notification Appl Circuit 0.000 0.744 #14 Solid 2.52 144 0.73 19.86 2.65% PGM-1/0#4 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 165 0.83 20.40 0.00% I' Il PGM-I/O#5 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% l,. PGM-I/O#6 Notification Appl Circuit 0.000 0.176 #14 Solid 2.52 45 0.23 20.36 0.20% Total Standby Current(Amps) 0.244 3.340 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standb AH Re.uired 5.844 0.278 Total Alarm AH Re.uired Total Combined AH Required 6.12 Command Shortcuts ' Multiply By The Derating Factor 1.20 Configure Circuits Print Page Minimum Battery AmpHours Required 7.35 17ah Batteries used I 1i a t t :t' Ezisit.r.r r xrnti:r Circuit Configuration Project Information Project Name: River Terrace East Condos Project ID: 0 Prepared By: D Phipps Date: 8/29/2018 Ckt. Number: PGM-I/O#1 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit V Qty Device Current Draw Each Current Draw Total is Standby Alarm Standby Alarm 2 System Sensor H-LF Low Freq. Sounder 0.000 0.138 0.000 0.276 3 System Sensor L Series Horn Strobe Wall(30cd; 0.000 0.074 0.000 0.222 1 System Sensor L Series Horn Strobe Wall(75cd') 0.000 0.121 0.000 0.121 2 System Sensor L Series Strobe(15cd) 0.000 0.043 0.000 0.086 0.000 0.000 Totals 0.000 0.705 Ckt. Number: PGM-I/O#2 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit • Current Draw Each Current Draw Total Qty Device Standby Alarm Standby Alarm 9 System Sensor H-LF Low Freq. Sounder 0.000 0.138 0.000 1.242 1 System Sensor L Series Horn Strobe Wall (15cd 0.000 0.054 0.000 0.054 Unused 0.000 0.000 0.000 0.000 is Unused 0.000 0.000 0.000 0.000 O.000 0.000 Totals 0.000 1.296 Ckt. Number: PGM-I/O#3 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit 1r Qty Device Current0.000 Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor H-LF Low Freq. Sounder 0.000 0.138 0.000 0.690 0.054 0.000 0.000 1 System Sensor L Series Horn Strobe Wall (15cd 0.054 0.000 Unused 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 k Totals 0.000 0.744 I'. is 9Y i i ' 'i i si> Ilk h`p III Circuit Configuration _ 'roje n orma ion Project Name: River Terrace East Condos Project ID: 0 Prepared By: D Phipps Date: 8/29/2018 Ckt. Number: PGM-I/O#4 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification apps Circuit vr Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number PGM-I/O#5 Panel ID: 5820XL 246, Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm I Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 i`; Totals 0.000 0.000 11 1 Ckt. Number: PGM-I/0#6 Panel ID: 5820XL I Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit • i` Qty Device Current Draw Each Current Draw Total r Standby Alarm Standby Alarm 1 System Sensor Outdoor Horn Strobe(75cd)) 0.000 0.176 0.000 0.176 0 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 i 0.000 0.000 Totals 0.000 0.176 II 11 1 F it f I ro', PPOTTER Project Name: River Terrace East Condos Standby Hours: 24 The Symbol of Protection Building H Alarm Mins: 5 - PSN-106 Installed By: Batt Efficiency%: 80% i Battery& Voltage Drop Designed By: Calculations Date: 8/27/2018 NAC Source Voltage: 20.4 Model#: PSN-106 Max Panel Current(amps): 10 Panel ID: Location Floor 1 Riser Room User assumes all responsibility to ensure the quantities and current draw values in this worksheet are accurate prior to submittal. Panel Standby(amps) Alarm(amps) Qty Part# Description Each Total Each Total 1 PSN-106 NAC Power Expander 0.075 0.075 0.075 0.075 Panel Standby: 0.075 Panel Alarm: 0.075 NAC Circuits(See NAC Configuration below) Standby(amps) Alarm(amps) r Ckt Use Description Total Total )' 1 0.00000 0.67300 2 0.00000 0.67300 li 3 0.00000 1.36300 4 0.00000 1.36300 5 0.00000 0.00000 11 6 0.00000 0.17600 1 AUX 0.00000 0.00000 NAC Standby: 0.00000 NAC Alarm: 4.24800 , Battery Calculation Summary Standby(amps) Alarm(amps) Panel Current: 0.07500 0.07500 NAC Circuit Current: 0.00000 4.24800 Total Standby: ` Total Alarm: . Standby Hours: 24 Alarm Mins: 5 AH Required: 1.80 AH Required: 0.37 .1 Total Combined Standby&Alarm AmpHours Required: 2.17 Efficiency Factor: 80% Required Battery AmpHours: 2.71 Battery AmpHours Provided: • i' je la' o t• l_ 1'' 11 ' Potter Electric Signal(C)2011 1 of 4 PSN-1000(E)Battery and Voltage Drop Calculation s ParrER Ma Symbda nomnm+ NAC Circuit Configuration& Voltage Drop River Terrace East Condos 8/27/2018 NAC 1 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 .1, Usage: Description: ii 4i Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL Min Volts Req d 1, #14 Solid 2.5 0.000 0.673 20.40 16 . Devices "", m ' Standb (amps) • r`'' Alarm(amps) Qty Lookup Type ) Description Each Total Each Total 4 User Defined System Sensor H-LF Low Freq.Sounder 0.000000 0.000000 0.138000 0.552000 ©User Defined System Sensor L Series Horn Strobe Wall 0.000000 0.000000 0.121000 0.121000 - I. -_- -IIM -_all - Mill 11111 -- 1k Total Standby: 0.00000 Total Alarm: 0.67300 NAC 2 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: '' WireT e O ms 1O0 lft Length 1-Way �' Max Load r„m s Volts @ EOL Min Volts Req'd #14 Solid 2.5 0.000 0.673 20.40 16 1iw wt Devices Standby(amps) Alarm(amps) Qty Lookup Type'. Description :1: ,"zra' Each Total Each Total 4 User Defined System Sensor H-LF Low Freq.Sounder 0.000000 0.000000 0.138000 0.552000 ©User Defined System Sensor L Series Horn Strobe Wall 0.000000 0.000000 0.121000 0.121000 11111 __ ,. MI -Ell, -_-_ �- - ;''. Mil 1 Total Standby: 0.00000 Total Alarm: 0.67300 `). Y' jf{ �iqq 1 t Y:. 4 L M 4'r I Potter Electric Signal(C)2011 2 of 4 PSN-1000(E)Battery and Voltage Drop Calculation 1l i` O POTTER j NAC Circuit Configuration& Voltage Drop(cont'd) River Terrace East Condos 8/27/2018 I itti NAC 3 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description r i 2"Ohms/1000ft Length 1-Way tual O Load(4jolts,@ EOL Min Vol O #14 Solid 2.5 0.000 1.363 20.40 16 f� e Circuit DevicesStandby atmp3T ,c� Asa , F ' Qty , Description . Each Tota, Each . Total 9 User Defined System Sensor H-LF Low Freq.Sounder 0.000000 0.000000 0.138000 1.242000 ©User Defined System Sensor L Series Horn Strobe Wall 0.000000 0.000000 0.121000 0.121000 Ell -_- t 13 Total Standby: 0.00000 Total Alarm: ( I I, 1 NAC 4 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 t' Usage: Description: Ohms/1000ft Length 1-WayActual Ohms Max Loadolts� :,,.„:_i.,,, I. ;l #14 Solid 2.5 0.000 1.363 20.40 16 0 Circuit DevicesStandby(amps) y� Alarm(amps) Qty Lookup Type Description Each Total ;' `' Each Total `:„°' 9 User Defined System Sensor H-LF Low Freq.Sounder 0.000000 0.000000 0.138000 1.242000 i 0 User Defined System Sensor L Series Horn Strobe Wall 0.000000 0.000000 0.121000 0.121000 -_-_ 1 -_- -- Total Standby: 0.00000 Total Alarm: ..'' 1.36300 i i ft )' 1-I . Potter Electric Signal(C)2011 3 of 4 PSN-1000(E)Battery and Voltage Drop Calculation QPorr� NAC Circuit Configuration& Voltage Drop(cont'd) River Terrace East Condos 8/27/2018 )' 1 NAC 5 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: 'i Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL Min Volts Req'd #14 Solid 2.5 0.000 0.000 20.40 16 "ll , s�� ' Circuit Devices ' Standby(amps) Alarm(amps) Lookup Type Description Each Total , . .. . Each Total d 4 } Total Standby: 0.00000 Total Alarm: 0.00000 ;)' NAC 6 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: }yaw+pkv?" ,E �f. `w`mwu u ^k �'� Ohms/ia„+;k Length 1.-„a ;w,,r�Actual Ohms Maxd(amps) Volts @ EOL Min Volts Req'd #14 Solid 2.5 0.000 0.176 20.40 16 it Devices e � Standby(amps) Alarm(amps) �� � Vi" + � Qty Lookup Type ,a',� Description ti� Each Total Each Total Q User Defined System Sensor L Series Outdoor Horn St 0.000000 0.000000 0.176000 0.176000 C N I. P EMI ME Total Standby: 0.00000 Total Alarm: 0.17600 AUX Power MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: ; 4. 4+ ype k � e. -Way Actual Oh n Max Load(amps) Volts @ Last Device Vol ..,.w,. . � a ce Min Vo � #14 Solid 2.5 1 0.000 0.000 20.40 16 � c c� ��w�� . �s ��,. it Devices ' Standby(amps) Alarm(amps) 3 1. Qty Lookup Type Description Each Total Each Total ,' . ME E I`` MI ( M IIII _= h __- 0.MIMI t Total Standby: 0.00000 Total Alarm: 0.00000 P Itage Drop Calculation I INTELLIKNIGHT FIRE ALARM CONTROL PANEL 410 SILENTIntelliKnight® Model 5820XL KNIGHTAddressable Fire by Honeywell Alarm Control System J The IntelliKnight System is the easy way !:: to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed fi intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. is Description 5820XL is an intelligent addressable fire alarm control panel it (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling : 1 line circuit expander, 5824 serial/parallel printer interface -^ t «. module (for printing system reports), and 5895XL intelligent i ,, power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring 'c) location. ' F Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol amu;_•,;, • Built in support for 127 SD devices, expandable to 508 SD j. devices using the SD protocol. ""'r(1: 4 �4 • Uses standard wire—no shielded or twisted pair required •1 • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • • Built-in synchronization for appliances from AMSECO® 6 amp power supply and maximum Gentex®, Faraday, System Sensor, and Wheelock® charging capacity of 35 amp hours (An additional cabinet enclosure is required for II• • FlexputTM I/O circuits batteries in excess of 18 amp hours) 1 • Supports Class B (Style 4) and Class A(Style 6) configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • Built-in annunciator with 80 character LCD display The 5820XL can be surface or flush • RS-485 bus provides communication to system accessories mounted • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit (SLC) uploads/downloads supports multiple device types of the same f. • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK (System Sensor) !' • Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing • SD single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FACP. INTELLIKNIGHT FIRE ALARM CONTROL PANEL I i IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights 5820XL features a 6 amp power supply required to start a new system. The General Alarm (Red): Flashes when in and maximum battery charging built-in keypad and 5860 remote alarm; solid when alarm silenced capacity of 35 amp hours.An additional annunciator give on-site access to all cabinet enclosure (PN RBB) is required programming.You can also program ', Supervisory(Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when Flexput circuits on 5820XL control can Software Suite,which is Windows° supervisory silenced be individually programmed to function based software. System Troubles(Yellow): Flashes as notification circuits, auxiliary power when a trouble condition exists; solid outputs, or initiation circuits that Built-In Digital Communicator when trouble silenced support both 2-and 4-wire smoke detectors. 5820XL features a built-in UL listed System Silenced (Yellow): On when an digital communicator for remote The 5820XL system operates on non- alarm, trouble or supervisory condition reporting of system activity and system twisted, unshielded cable when wired has been silenced but not yet cleared in compliance with standard wiring Programming.The communicator has System Power(Green): Flashes for AC practices as called out in the National the ability to seize two telephone lines failure; solid when power systems are Electric Code 760-51 specifications for to report alarms and troubles to a normal power-limited fire protective signalling monitoring facility. The communicator cables. No special wiring is required. supervises two phone lines and will System Application 5820XL provides 13 preset notification activate a trouble signal if a line failure cadencepatterns (includingANSI 3.41) is sustained for more than 45 seconds. 5820XL has one built-in signalling line Other communication features include: circuit(SLC)which supports multiple and four user programmable selections retry if communication fails, two phone devices dependent on protocol being for fire alarm notification. number capability, download phone used.Three additional loops can be Two programmable general purpose number capability and Touch-Tone or F added using the 5815XL SLC Form C relay outputs are provided on rotary dialing.The communicator is r expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco The 5820XL SLC loops support Additionally,the IntelliKnight system Contact ID.The format is selectable by features a built-in walk test and auto- account number. multiple device types, including: programming. Its innovative, dead-front s • Addressable photoelectric smoke cabinet design allows for flush or detector surface mounting. System maintenance • Addressable ionization smoke is easy to perform. detector WIN User Interface VA :L • Addressable heat sensor ..,..-�. f' The 5820XL built-in annunciator with • Addressable duct smoke detector 80 character LCD display and largiiier • Contact module easy-to-use tactile touchpad can be r ; ! • Relay output module used for system operation, NI Mk '8 Tr programming and maintenance. It has 0. OP , , - Addressable notification module five LEDs for alarm, supervisory, . • Addressable beam detector(SK system trouble, system silenced and protocol only) system power. System operations • Addressable multi-criteria smoke include silencing alarms and troubles, Approvals detector(SK protocol only) resetting alarms and the display of NFPA 13, NFPA 15, NFPA 16, alarm troubles and memory. The NFPA 72: Central Station; Remote • Addressable multi modules(SK system's non-volatile event history protocol only) buffer stores 1000 events for viewing Signalling; Local Protective SignallingIt from the built-in or remote annunciator. Systems;Auxiliary Protected Premises Thfollowing advanced sensor System operation can be initiated with Unit; &Water Deluge Releasing cape abilities are available with 5820XL: Service a mechanical firefighter's key or a valid . Suitable for automatic, . • Automatic drift compensationmanual,waterflow, sprinkler ``' P 4-to 7-digit operator's code. supervisory(DACT non-coded) 3 • Maintenance alert signalling services. Programming 9 g • Built-in sensor test to comply with The IntelliKnight system offers several Other Approvals: UL Listed; NFPA 72 calibration testing options to simplify and speed up CSFM 7170-0559: 135; I. requirements programming. The JumpStart®feature MEA 429-92-E Vol.VI; FM Approved i minimizes programming 4 IINTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 582OXL Addressable Fire Alarm Control Panel 1 Based IntelliKnight 5820XL "M"ol°" Faddy Addressable Fire Alarm System Management Software SK(System Sensor) Protocol Devices �.... NFndows Based UplCownload Software 11E1 T � atble lCS H Comp _,.. Receiver t g � utomation '.r I Software Internet 5820XL SK-212UD Connection VisorAlarm I IP Communicator 5865XL LrefgensPmrer lJgdlPe ► —♦ :3F-rnC Peas - �, ,, •n d . ii I ' Ever 1 PIIIIIn Ii. . ,. F I% t 5875ML 8 1 k� •PS.32,ilowill - i SIC boards, ,; 5800 5824 rt -'.omotc^rnunoaer Prrtcr Oona Modu's `y� U lhrl \,ims7.:Alr) t 7i �_" 6 Flesput" 1 7 ' 815XL ».,Ilhi110 Circuits c r can be inputs _LC Expender !'I 2 or outputs •, 6 Hama—a— 1 Q vo circuits 5 ;, a ~roF can be Inputs i or outputs L h [el:9Wbef Ha,ervdNvC c ® ifil a Feil s:r.om Prat SkPflletl Sm.LrYPaUt • lyye .. m I , Ili: it 44P I I i ( � I � SK4on SK-Moultor SK•Iso SK -6 SK-Control B200SR Sit-Acclimate SK -6/P r... AAdrossado Adxessetle r.ul'�soletx Addressable Sunoms°a sounder Mutyrtera Zcre = is a I I1,xr I Monro, Mwule Nutrlreton CI,.a Base wok,- Nell.", 5860 Detectcr Mod,o maid° Module dotoctcr \lo1Jn remote Annunoetor I 8K-Photo hoto- SKii0ttX SKAdimamon-26K-Hea-Heat-R 6 Relay 822461 Ba1�.P SK•Phdo-T "L',.d Pule Den ulsatar SK -H at lT ke�a/ +.taur newrlrr 5880 AH.a r...:,,, Macule Cus Moritcr SKHerayty base vase ease LEO aware, lhetcol Darr .Hrwo Re.ys ;liQ.sade — Input Module II Gateau- wt. ....ors 1 E Y ,..�e w • �1 II 5883 P. 10.16 .1Mul,1a I 8K•Bean SK-Mon-10 BK-PUII-DA 8K-Duct SK-Mulmon SK-ReI '-6 BKZone SK-Relay SK-Beam-T Ad±e;»tlo S t_pun_6A Ayxasetia Mcrl:or P?m.Gonad AAd Auaatl3 Addo..atl> Acaccsadc Mond" Add!ensntiel Du¢ Module ticdud n:erfa_e Pr/n rwa,rlete.Yor Modal P.I Sllon D/eda tJnerra Find Jle Y 133:11-- 5865-4 or 58653 `' I Use the 5880 to control up to 4 f•_-. _ED 4A/lea) f 5683 Relay Interface Modules . - I. }f 4 INTELLIKNIGHT FIRE ALARM CONTROL PANEL t IntelliKnight Model 5820XL f Addressable Fire Alarm Control Panel Specifications S-BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz, 2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using Total Accessory Load: 6A @ 27.4 VDC, and 5860R is red. a PC. Upload and view panel account power-limited 5815XL Signal Line Circuit Expander information, event history, and detector Standby Current: 215 mA The SLC expander is used to add more status. Alarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system. 5820XL supports three (SKSS) Flexput Circuits: 5815XL's. Each 5815XL can support 99 Powerful end-user facility management Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector it programmed individually as: 127 SD devices. status and event history via modem or ! Notification circuits: 3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power, 6 Flexput I/O Plex-1 Auxiliary power circuits: 3A @ 27.4VDC circuits and 2 Form C relay circuits to a Dead front cabinet door with clear per circuit, power-limited 5820XL system. window to limit access to the FACP. Initiation Circuits: 100 mA @ 27.4VDC 5496 Intelligent Power Module RBB per circuit, power limited A 6 amp notification power expander Remote battery box accessory cabinet. that provides four power-limited notifi- Use if backup batteries are too large to Physical cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 5880 LED/lO Module 16"W x 10" H x 6" D 14.5"W x 24.75"H x 3.9"D Features 40 LED outputs, 8 normally (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs, and one piezo SD505-DTS-K output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR. Provides remote key 16.2"W x 26.4"H x 4.2"D Remote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) Features 30 programmable LED (15 of detector alarm. red and 15 yellow)outputs, and a piezo SD and SK Devices Weight: 28 lbs. (12.8 kg) sounder.The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7.0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet. Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module I accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log FCC Part 15 and Part 68 approved of system events, detector status reports, and event history. Interfaces ,1 ` Type of Jack: RJ31X(two required) with building control system. liii( r - f. SILENT This document is not intended to be used for installation purposes.We try to keep our Made in America it" KNIGHT product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472 PN 350210 Rev H2 I' by Honeywell Phone:(203)484-7161,Fax:(203)484-7118.www.silentknight.com. ©2012 Honeywell International Inc. 1 IntelliKnight&JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight :1: INTELLIKNIGHT ACCESSORY t. tSILENT 5860 Remote Annunciator i KNIGHT _ a by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every I area within your facility 1 • Now you can operate and program your IntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. i Wire runs can be up to 6000 feet from the panel. E I_ For more information about the IntelliKnight system, or to locate your nearest source, please call ` 1-800-328-0103. I l' Description • Available in red or light gray if Features include an 80-character • Support for simultaneous use of j backlit LCD providing easy-to- multiple 5860s i understand system messages. The • RS-485 interface to panel }' -- annunciator is ergonomically • Operation and appearance is .' designed with over-sized buttons identical to 5860 built-in .1 Ifor the most frequently used annunciator ., , • features, like Reset and Silence. • On-board piezo sounder audibly - - =° indicates alarms, troubles, and In addition to status messages supervisories s displayed on the LCD, there are . Five status LEDs for alarm, five LEDs for alarm, supervisory, • supervisory, trouble, silence and trouble, silence, and AC power AC power conditions status. • Wiring lengths up to 6000 ft. from 5860 The annunciator is available in gray the FACP (depending on wire Environmental to match virtually any decor and gauge and number of devices on Operating Temperature: 32°F– red for applications where the SBUS) 120 F (0 C–49 C) annunciator must stand out. The UL listed, complies with NFPA 72 Humidity: 10% –93% non- annunciator enclosure can be • CSFM approved condensing I surface or flush mounted.A trim Electrical Specifications Compatibility ringkit is available for surface Operating Voltage: 24 VDC p 9 9 The 5860 is compatible with the mounting. Standby Current: 20 mA max following FACP's: Features Alarm Current: 25 mA • 5820XL Addressable Fire Control ( • 80-character backlit LCD display Wiring Distance: 6,000 max. from Panel (4 lines with 20 characters on FACP (depending on wire gauge • 5820XL-EVS Fire Control Panel each line) and number of devices on the with Emergency Voice System • Tactile and audible feedback SBUS) • 5808 Addressable Fire Control • Accepts user codes or fire Panel fighter's key Mechanical Specifications • Larger keypad buttons for system Physical 9.1"W x 7.4" H x 1.5" D •• Panel0 reset Fire Control reset and silence (23.1 W x 18.8 H x 3.8 D cm) t • Install up to twelve 5860s per Shipping Weight: 2.8 lbs (1.3 kg) 5820XL/EVS or 5808 system Color ' - Install up to eight 5860s per 5700 5860R: Red system ©2014 PN 350224 Rev G Honeywell International Inc 5860: Gray i r fi INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator Engineering Specifications <i The main control must have a built-in annunciator and must support up to 12 remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator.All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System , Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of.040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. !:. } t f' Wire Runs Up to 6000 Feet From FACP OM R; at= SBUS w 5860 5860 5860 4' • Up to 12 5860s Per IFP-100/ECS or IFP-1000/ECS System •Up to Eight 5860s Per 5700 System Compatible IntelliKnight FACP 1.-- Listings Listings Ordering Information NFPA 72; UL Listed; 5860R Remote Annunicator four line LCD ' CSFM 7170-0559: 135; annunciator with 20 characters per line. MEA 429-92-E Vol. IX; Red FM Approved 5860 Remote Annunciator four line LCD annunciator with 20 characters per line. Gray Accessories 5860TR Red Trim Ring for surface mounting Ir 5860TG Gray Trim Ring for surface mounting ii SILENT This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all �j KNIGHT �■ specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight by Honeywell 12 Clintonville Road, Northford,CT 06472-1610.Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support, Please call 800-446-6444. www.silentknight.com Assembled in America P POTTER PSN SERIES ® The Symbol of Protection POWER SUPPLY - UL,cUL,CSFM Listed • PSN-64 has 6 amps regulated with 4 Outputs • PSN-l06 has 10 amps regulated with 6 Outputs • Outputs Rated at 3 amps maximum each +' • May be configured as up to three class"A"Style"Z"notification circuits tw w, -- it',„ • ;.�� I • 3 amp,24 VDC programmable output power WI • Supervised Battery Charger 273 @ lA(supports 7-55 All batteries) • Easy to install cabinet with leveling mounts and key lock "' • Wiring knockouts provided on sides and top of cabinet • Two Trouble Relays(5A at 30VDC) General System Trouble(programmable for AC delay) Low AC Trouble with optional delay settings • Diagnostic LED's patent pending Status LED's for Active NAC and NAC trouble conditions Status LED's for Earth Fault(Amber),AC(Green),Battery Fault(Amber) • Trouble Memory feature captures troubles which have previously restored C UL DS • Synchronized notification appliance circuits ` Potter/AMSECO®,Wheelock®,Gentex®,System Sensor® • LISTED lit S2930 7315-0328:0189 • Configurable output circuits(DIP switch sets options for each circuit) • 15 mA at 8-33 VDC input trigger Product includes a 5 year warranty • Reference EOL allows 2K—27K EOL value to be used • Quadrasync provides panel wide synchronization of same or multiple brands Dimenions: 16 1/8"W x 16 3/4"H x 3 1/2"D • PassThru mode allows the Outputs to match the Input Signal Electrical Specs: { Stock Number:3006436 PSN-64 Red Enclosure • 120/240 VAC 50-60 Hz input 3006437 PSN-106 Red Enclosure • 5.1 Amps @ 120 VAC or 2.5 Amps @ 240 VAC 3006446 PSN-106 Black Enclosure • Standby Current 60 mA • Alarm Current 200 mA* *no external load Description • : The PSN series of notification power supplies offers reliable notification Sensor®strobe devices.Each output can be configured the same sync power with unprecedented versatility.The power supplies offer either protocol or set independently. 6 or 10 amps of continuous power through 4 or 6 outputs respectively. In addition,the panel has an input PassThru mode allows the outputs Each output is rated at 3 amps and it may be used continuously without to follow the input signal and sync up the input flash.The panel will any derating. recognize the type of input being supplied and pass this through to the s' The power supply operates on either 120 VAC or 220 VAC power input outputs with the same pattern.This input pass through can be selected { and has a regulated 24 VDC output.In addition,the panel can charge on each output independently. up to 55 AH batteries and leads the industry in housing up to 18 AH The power supply contains simple dipswitch programming and LED batteries.The cabinet is constructed out of 18 gauge cold rolled steel and indications providing the installer indications of the operation and the has a durable red powder coat finish.In addition,a key lock is provided ability to correct any faults.A Trouble Memory is provided to allow an for securing the door.Ample electrical knockouts are provided on the installer to review past troubles and make the necessary repairs.Each sides and the top,allowing the installer options for running wires and output has an LED to pin point the exact circuit where a problem may maintaining the correct separations. have occurred.Relays are provided for monitoring the general system The power supply offers an industry leading Quadrasync function that and AC failure. i allows for multiple strobe circuits of different brands to be synchronized Each output and be independently configured for various applications to flash at the same time.The panel can have four different brands each and installations.Each output can be independently configured for Class connected to its own circuit and all of the strobes flash together. A or Class B operation,constant power,ANSI Temporal Code 3,Single, Each output can independently be configured to provide one of Multiple or Combo Inputs or Door Holder Power. four synchronizations or steady power. This provides unequivocal flexibility in new and retrofit installations.The panel can be configured to synchronize Potter/AMSECO®, Gentex®, Wheelock® and System Potter Electric Signal Co.,LLC •St. Louis,MO•Cust Service: 866-240-1870•Tech Support: 866-956-1211 •Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8910013-REV C2 PAGE 1 OF 2 11/12 1 r { i i PPOTTER PSN SERIES • ® The Symbol of Protection POWER SUPPLY ;, • PSN-106 Wiring Diagram 0 120/240 VAC GND FAULT F,, 6j Jumper Position DETECT ENABLE ON11=.I OFF 120VAC 50Hz-60Hz 240VAC 5011z-60Hz Black Connect to separate White unswitched AC circuit Ground — status LED's ------------------, NACI NAC2 NAC3 NAC4 NAC5 NACb DC Io - — o S7 •S8 o ►,1 fJ. Q u u `" Ie9g96e9ei I'I'llll'Il'I+1 0 0 — H N ❑ o o 1.1.1.11.1.1.1COMM• Fuse / II I o Ie999ee�s2 ml [L) iCr.� Elf 1E4 CI 0 o ieeaeeels3 0 0 0 new S4 Fa Installed ' Interconnect. AC Power O R1'I'1'It S5 Low Battery 0 Gnd Fault L , o NI'1IRisb Bulk Options I 8 ■ com 0 1f►R 1f 1R�}R 1f PRP!PER 11011011, 1f 1f 1�iTf}�Tf T1'►f 1f 1f u,....:.au V 7,. .C5 . I 0 I I_.--I_,_I_I ''ACI NAC2 NAC3 NAC4 NAC6 P 1 IN2 LOW AC xt�nxwT { - + - + - + - + - + _ + /- MT - FOTi - +EDI NC COM NO NC COM NO Battery+ Battery- 1 Common relays are O a E.o.I1 non-power limited. t Lo.L. E.O.L. f DC Power Trigger + + Battery connection(non-power limited). Note:PSN-64 and PSN-106 draw 15 mA when polarity reverses and the power Use two(2)I2V batteries connected in series. supply is triggered.There is no current draw in Standby Mode. Engineering Specification The contractor shall supply and install the Potter PSN power supply.The assemblies.The LEDs shall have distinct flash patterns to provide further r. power supply shall operate on either 120 or 240 VAC input.The panel indication ofthe troubles present.The panel shall have selectable Trouble k shall be capable of continuous load power without any degradation to Memory to provide the installer an indication that a past trouble existed the main supply or the distribution board.The cabinet shall be capable of on a circuit for diagnostic purposes. housing up to 18 AH batteries and the panel shall be capable of charging Each output of the power supply shall be capable of 3 amps of continuous up to 55 AH batteries in an external cabinet. power without degradation over time.The power supply shall provide for The panel shall have dip switches for simplistic configuration of the multiple circuits of strobe appliances.The power supply shall synchronize system and LEDs to provide visual indication to the installer of the status the flashes of any of the above listed strobe appliances on a per circuit of the system.The dip switches shall allow for AC power delay selection, basis.Up to four different strobe circuits may be connected and all of Class A/B operation per output,Door Holder Power options,constant the strobes shall flash in unison as required by UL 864.In addition to auxiliary power,trigger input type,ANSI Code 3 Temporal Code,Pass this Quadrasync feature, the panel shall allow any of the four above I Thru(input tracking),Potter/AMSECO®sync,Gentex®Sync,System mentioned sync patterns as an input and pass this signal through and 1 Sensor®Sync or Wheelock®sync.The LEDs shall provide indication synchronize the outputs to match the input flash pattern. of communication between the power supply and distribution circuit PRINTED IN USA MKT.#8910013-REV C2 PAGE 2 OF 2 11/12 ie INTELLIKNIGHT ACCESSORY SILENT SK-Photo, SK-Photo-T 1 KNIGHT and 13.,, SK-PhotoR by Honeywell Intelligent Photoelectric Smoke Sensors 1: 1 The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). . ! For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description SK-Photo and SK-Photo-T are plug-in • Optional remote LED annunciator (System Sensor®PN RA100Z) • Plug-in mounting provides ease of type smoke sensors that combine a installation ► photoelectric sensing chamber with • Tamper-proof feature available on :;E:;;,,,.. addressable analog communications. mounting bases I Point ID capability allows each • Listed for use in duct applications detector's address to be set with rotary address switches, providing exact • Rotary address switches for fast tI y detector locations for selective installation maintenance when chamber • UL Listed 11 contamination reaches unacceptable • FMA roved w levels. pp SK-Photo and SK-Photo-T have a Specifications unique optical sensing chamber that is Physical ' engineered to sense smoke produced Height:2.0" (5.0 cm) by a wide range of combustion Diameter:4.1" (10.4 cm)installed in SK-Photo (Base included) sources. In the SK-Photo-T, dual 6501 base electronic thermistors add 135°F(57°C) Installation thermal technology to maximize Electrical detection. Operating Voltage: 15-32 VDC The SK-Photo and SK Photo T plug Standby Current: into a compatible IntelliKnight-series The SK-PhotoR is a remote test detector base.The SK-PhotoR is a capable detector for use with the 300 pA @ 24 VDC Maximum remote test capable detector head DNR/DNRW duct smoke detector. (not Alarm Current: 6.5 mA @ 24 VDC max included within the DNR(W)duct included) (with LED on) smoke detector. , Environmental Operating Temperature Compatibility Features SK-Photo: 32°— 120°F(0°C—49°C) SK-Photo, and SK-Photo-T are • Sleek, low-profile design SK-Photo-T: 32°—100°F(0°C—38°C) compatible with the following detector 1: • Base included Humidity: 10%—93% non-condensing b6210LP ases: W Other Ratings 6" base (included) • Reliable analog communications forB501 2 wire base t' trouble-free operation SK-Photo-T Thermal: Fixed � p temperature set point 135°F (57°C) B224RB Relay base t • Age resistant polymer housing B224B1 Isolator base `r Velocity: 0—4000 fpm (0—20 m/sec) • Dual electronic thermistor design on p B200SR Sounder base the SK-Photo-T The SK-Photo, SK-Photo-T, and SK- • Superior EMI resistance for reliability PhotoR are compatible with the • Simple field cleaning for code following IntelliKnight FACPs: compliance 5820XL • Variety of mounting options to meet 5820XL-EVS any application 5808 5700 • Dual LED indicators for 360°visibility 5600 (Rev 2.0 or higher) • Detector transmits signal to indicate maintenance is required INTELLIKNIGHT ACCESSORY t . Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed-and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B210LP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the I need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. SLC IN OUT { ff'far."citCompatible FACP tr cc !i Compatible Com P ;:m P:� RA100Z(Optional) reiN at -.- ��r1b:: raj er., i.,. ..„,,,,_,,._ cak,„„,, ‘11.111 ikiiiiiiV . %Ire , ■ ■ Class A Optional Wiring / Wiring SK-Series Detector Mounting Bases 0 SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350118 Rev E subject to change without notice. For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com r. II' i I I< INTELLIKNIGHT ACCESSORY SILENT SK-Heat, SK-Heat-HT 1 4% KNIGHT and by Honeywell SK-Heat-ROR Addressable Thermal Heat and Rate-of-Rise Detectors The SK-Heat, SK-Heat-HT, and SK-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with Silent Knight 4 IntelliKnight series Fire Alarm Control Panels (FACPs). t IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight li panel recognizes each detector by its specific address, so precious seconds are not wasted in determining iilocation of an alarm. 7 Description • Detector transmits signal to SK-Heat, SK-Heat-HT and SK- indicate maintenance is required Heat-ROR are intelligent sensors • Plug-in mounting provides ease _ ;, that utilize a state-of-the art of installation `„ thermistor sensing circuit for fast • Optional remote LED annunciators response. Sensitivity is (System Sensor® PN RA100Z) �� ' continuously monitored and • Tamper-proof feature available on reported to the FACP. Point ID \\ capability allows each detector's mounting bases address to be set with rotary • Rotary address switches for fast ' address switches, providing exact installation SK-Heat(base included) idetector locations for selective • UL Listed SK-Heat-ROR: Rate-of-rise maintenance when chamber detection 15°F/min (8.3°C/min) ' contamination reaches Specifications unacceptable levels. Physical Compatibility Height: 2.0" (51 mm) SK-Heat is a fixed temperature Diameter: 6.1" (155 mm) installed The SK-Heat, SK-Heat-HT and SK- sensor that uses a thermistor Heat-ROR are compatible with the sensing circuit to produce 135°F in B210LP base following detector bases: (57°C)fixed temperature alarm. Shipping Weight: 4.8 oz (137 g) Electrical B210LP 6" base (included) SK-Heat-HT is a variable high Operating Voltage: B501 2 wire base temperature detector that provides 622481 Isolator base high temperature detection at 15 to 32 Volts DC Peak B224RB Relay base 135°F - 190°F. (57°C - 88°C) Standby Current: B200SR Sounder base 300pA @ 24 VDC SK-Heat-ROR is a rate-of-rise The SK-Heat-HT and SK-Heat- temperature sensor with 135°F LED Current: 6.5 mA@ 24 VDC ROR are compatible with the (57°C)fixed temperature alarm. Environmental following IntelliKnight FACP's: i Features Operating Temperature 5820XL ` SK-Heat& SK-Heat-ROR: 5820XL-EVS • Reliable analog communications -4°- 100°F (-20°C—38°C) 5808 for trouble-free operation 5700 • Age resistant polymer housing rat- To— 150°F20°C—66°C) The SK-Heat is compatible with the i • Innovative thermistor sensing following IntelliKnight FACP's: circuit Humidity: 10%—93% l noncondensing 5820XL • Superior EMI resistance for 5820XL-EVS reliability Thermal Ratings 5808 • Variety of mounting options to SK-Heat: Fixed temperature alarm 5700 meet any application 135°F (57°C) 5600 (Rev 2.0 or higher) • Dual LED indicators for 360° SK-Heat-HT: High temperature heat sensor 135°F- 190°F (57°C- 88°C) P/N 350120 Rev. F visibility ©2016 Honeywell International Inc. INTELLIKNIGHT ACCESSORY i; Model SK-Heat, SK-Heat-HT, - SK-Heat ROR Addressable Thermal and Rate-of-Rise Thermal Detectors ii Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent Thermal Sensor Silent Knight Model SK-Heat, SK-Heat-HT or SK-Heat-ROR. The base included shall be B210LP. The Heat detector shall have a flashing status LED for visual supervision. When the detector is activated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required.Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. -------------\) _-% SLC IN OUT / Ei iii Ci r i Compatible FACP all zu=1 RA100Z(Optional) +I P. :.." ek.:. ,...„ '14, I:- r ... waipl ...... por \air \mil, .s.......:_ Class A Optional Wiring / Wiring SK-Series Detector Mounting Bases M F, Accessories M02-09-00-Test Magnet with Telescoping Handle. 1r.' RA100Z-Remote LED Annunciator. XP-4-Extension Pole for XR2B. Extends from 5—15 ft. RMK400-Recessed Mounting Kit.Provides low profile for use with T55-127-000-Detector Removal Head. B501. I` XR2B-Detector Removal Tool.A removal and re-placement tool for BCK-200B-Black Detector Kit. For SK-series detectors. SK plug-in detectors. Includes the T55-127-000. *Unless otherwise noted,specifications apply to all SK thermal M02-04-01 -Replacement Test Magnet. detectors. I.' This document is not intended to be used for installation purposes.We try to keep our product information up-to- SILENTdate and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are NI KNIGHT subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road Northford, CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. For Technical Support,Please call 800-446-6444. by Honeywell www.silentknight.com ill k{ t I i, INTELLIKNIGHT ACCESSORY it SILENT SK-Pull-SA and SK-Pull-DA El,- KNIGHT by Honeywell Intelligent Pull Stations ii The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knights IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight ' � PULL' 1 DOWN iv Intelliknight series fire alarm control panels (FACPs). Features Y • Installer can open station without causing an alarm condition Slu IN f • Dual-color LED is visible through handle of station blinks ° green to indicate normal operation and remains steady red j in an alarm condition SK-Pull-SA r • Key operated test and reset lock using lock plate actuator , , • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG)controls and operating mechanisms I PUSH IN guidelines (Section 4.1.3[13]) PULLDOWN • Meets ADA requirement for 5 lbs maximum pull force to active r • Shell, door, and handle molded from durable LEXAN® ri *�c"ter 1., • Reliable analog communications for trouble-free operation i { • Braille text on station handle SK-Pull-DA • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled The SK-Pull-SA and SK-Pull-DA are compatible a oi • Rotary address switches for fast installation with the following IntelliKnight FACP's: 5600 • UL Listed, including UL 38, Standard of Manually Actuated 5700 Signaling System 5808 5820XL 5820XL-EVS 1 i. INTELLIKNIGHT ACCESSORY Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. I Class A 114 In l - class B Compatible FACP Liiin I LA, 1 II it 11 e t i I! f S e e t 1 I'. 6 I I I t :. II t 1 Class A Wiring: - 1" Class B Wiring: ' Wiring SK-Pull-SA&SK-Pull-DA Pull Stations Specifications Electrical Physical Operating Voltage: 15-32 VDC Height: 5.5"(14 cm) Average Operating Current(LED flashing): 300 pA Width:4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) 11 Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32°— 120°F (0°C—49°C) Bi-Colored LED: Humidity: 10%—93% non-condensing 4' Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST)normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-I/O Surface backbox j SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover NIKNIGHT all specific applications or anticipate all requirements.All specifications are FORM#350135 Rev C ik subject to change without notice. For more information,contact Silent ©2013 Honeywell J ' by Honeywell Knight 12 Clintonville Road, Northford,CT 06472-1610 International Inc. Phone: (800)328-0103, Fax:(203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com 4.i i a 1i I: INTELLIKNIGHT ACCESSORY r; 1 1 SILENT SK-Relay 14 KNIGHT Intelligent Relay Module by Honeywell The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of each 1 module is selected using the built in rotary switches. For more information about the IntelliKnight system, or to locate you nearest source, please call 800-328-0103. y 1 fi 1 Description The SK-Relay is an addressable relay module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). � The SK-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains ° � `� � ,�� " two isolated sets of Form C contacts, which operate as a , DPDT switch. No supervision is provided for the ,vw notification appliance circuit. 1; The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK- SK-Relay Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls Installation the SK-Relay, the relay is triggered by the FACP. The SK-Relay mounts directly into a 4" square electrical box. The box must have a minimum Features depth of 2-1/8".A surface mount electrical box • Two sets of Form C contacts (System Sensor® PN SMB500) is available from • Rotary address switches for fast installation Silent Knight • Contacts are rated for a variety of amps (see Specifications) Compatibility The SK-Relay is compatible with the following t' • Panel controlled status LED that flashes green in IntelliKnight FACP's: I. normal state and is solid red in alarm 5820XL 5820XL-EVS • Relay programming is completely flexible—can be 5808 jmapped to zone conditions 5700 l' 5600 (Rev 2.0 or higher) • Polling LED visible through the cover plate II • Attractive ivory cover plate i • SEMS screws for easy wiring P/N 350127 Rev E • UL Listed ©2015 Honeywell International Inc. INTELLIKNIGHT ACCESSORY Model SK-Relay Intelligent Relay Module To Next Device - 1 If Any Wiring to Terminals 3-9 is Not Power + t Limited,the CB500 Barrier is Required.The CB500 Includes a Non-Power Limited Label, l< n n Which Must Be Placed Over the Power Limited 0 O O ^ Terminal Information on the Name Plate Label. ° Relay Common 2 , 9 ors. 0 ■I Normally Closed 2 CI ;a1 i 11: Normally Open 2 30 7 ''• 2E2" Relay Common 1 I'r • o/ ' 3 i ii - From Compatible FACP Normally Closed 1 e . tl.�,4 , + or Previous Device LOOP n Module Does Not Supervise ('1 ° O j'� Normally Open 1 Controlled Circuits .V (/, U U Wiring the SK-Relay Module Specifications Ordering Information Physical SK-Relay Relay Module 4.675" H x 4.275"W x 1.4" D Shipping Weight: 6.3 oz (196 g) Accessories SMB500 4" Square Surface Mount Electrical Box Environmental CB500 Module Barrier Operating Temperature: 32°F— 120°F (0°C—49°C) Humidity: 10%—93% non-condensing �, Electrical Relay Contact Ratings Operating Voltage: 15—32 VDC End-of-Line Resistance: Not used 3.0A @ 30 VDC resistive i SLC Standby&Alarm Current: .255mA max @ 24 0.9A @ 110 VDC resistive 4 VDC (one communication every 5 sec with LED 0.9A @ 125 VAC resistive enabled) 0.5A @ 125 VAC inductive (PF = .35) 0.7A @ 75 VAC inductive (PF = .35) This document is not intended to be used for installation purposes.We try to keep SILENT ���.�... KNIGHT our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change Pilwithout notice. For more information,contact Silent Knight 12 Clintonville Road, miniiiiiiiiimmomminmi by Honeywell Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support,Please Call 800-446-6444. www.silentknight.com Asembled in USA `I 1 INTELLIKNIGHT ACCESSORY e. SILENT SK-Minimon KNIGHT by Honeywell Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. n Description �, The SK-Minimon is an addressable ;gra �,. monitor modules for use with the ':fz.:'..?Llillz.*:'.:;!::.,.,'!C''.:7.'''.::':'.'':'.7!::f- ' IntelliKnight fire alarm control panels (FACPs). The SK-Minimon acts as an interface to contact devices, such asll r: switches and pull stations. f The SK-Minimon supports Class B . supervised wiring to the load device. Conventional 4-wire smoke �` detectors can be monitored for alarm and trouble conditions Ji irs The SK-Minimon can be mounted in a single gang junction box • J. directly behind the il monitored device. Its small size and light SK-Minimon weight allow it to be installed without rigid mounting Specifications Compatibility requirements. The SK-Minimon is compatible with Electrical Features Standby Current: 400 uA max @ the following IntelliKnight Systems: • Single contact monitor 24 VDC with comm. 5820XL • SK-Minimon support for Class B Voltage Range: 15 - 32 VDC 5820XL-EV (Style B) contact monitor wiring End of Line Resistance: 47 k Ohms 5808 5700 • Small and lightweight size allows physical 5600 (Rev 2.0 or higher) for flexible mounting options Dimensions: SK-FFT il • Rotary address switches for fast 2.75" W x 1.3" H x 0.5" D i' installation Weight: 1.2 oz (37 g) • UL listed Environmental Listings J. Operating Temperature: UL 32°F— 120°F (0°C—49°C) CSFM ' Humidity: FM t. 10%—93% non-condensing INTELLIKNIGHT ACCESSORY t SK-Minimon . Intelligent Monitor Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. 't i, 'FF SLC la — m, / OUT w,, / AIN- j iS� 1 ADDRESS 0 1 14 �, 18 li .._2 2 12 , C, Compatible FACP 11 4 19a7�6 LOOP 987y65 TENS ONES ..._t-\.__(1 rL_(rL- - + + — CD XI E Eao. o `D , 4 ° k O O +--1 ;a Other Devices Wiring the SK-Minimon i', SILENTNi It This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover KNIGHT all specific applications or anticipate all requirements.All specifications are FORM#350133 Rev E subject to change without notice. For more information,contact Silent ©2013 Honeywell International Inc by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800)328-0103, Fax:(203)484-7118. For Technical Support, '. Please Call 800-446-6444. www.silentknight.com iiI 4 i, f i'; INTELLIKNIGHT ACCESSORY j< 0 1 lith SILENT SK-Monitor-2 4 Ni 1 Ni KNIGHT by Honeywell Intelligent Dual Monitor Module The SK-Monitor-2 module is capable of monitoring two separate Class B circuits simultaneously, making it ideal for waterflow tamper switch and flow switch monitoring. I, 1 For more information about the IntelliKnight system, or to locate you nearest source, please +' call 1-800-328-0103. t Description 1; The SK-Monitor-2 is an addressable monitor =i 4 module with two initiating circuits for use with . Silent Knight IntelliKnight series fire alarm °� \ °va'`� v control panels (FACPs). The SK-Monitor-2 acts � ' cam. as an interface to contact devices, such as � �v s,r �y waterflow switches and pull stations. The SK-Monitor-2 supports Class B supervised \��\ ,\\\ \ v\�v\'\'' ''\'*av wt uVat v yc ��� vya '0\ y wiring to the load device. Conventional 4-wire ,y\ � `� ��� � vv \v smoke detectors can be monitored for alarm i; and trouble conditions. SK-Monitor-2 4 r Installation Features SK-Monitor-2 mounts directly into a 4" + • Monitor two circuits, with unique addresses, square electrical box. The box must have j simultaneously a minimum depth of 2-1/8". A surface i! • Support for Class B wiring mount electrical box (System Sensor® number SMB500)supervised part is available from • Panel controlled status LED that flashes green Silent Knight. 1 in normal state and is solid red in alarm Compatibility • Attractive ivory cover plate The SK-Monitor-2 is compatible with the • Rotary address switches for fast installation following IntelliKnight FACP's: • SEMS screws for easy wiring 5700 • UL Listed 5808 5820XL 5820XL-EVS G p;. 4; r i 11 I INTELLIKNIGHT ACCESSORY44 T t Model SK-Monitor-2 1 Intelligent Dual Monitor Module + To Next Device n n [ - ; Oq 1`e F, ,O � , Compatible FACP U U ��� �� ,l? Two Initiating Device Circuits NFPA Style B Power Limited 230 pA Max©12 VDC Max � n n / SLC i OUT IN 1—f—tr—/ 0 O o / a.:TI 1:+x.7 a .� ,.., ,c,\, o „,,, o0 u u Wiring SK-Monitor-2 Modules 11 I- Specifications End-of-Line Resistance:47K S2 l Physical Max IDC wiring resistance: 1,50052 ' Height:4.5” H x 4"W x 1.25" D SLC Line Loop Resistance:4052 max. Shipping Weight: 6.3 oz(196 g) Environmental Electrical Operating Temperature: 32°F—120°F (0°C—49°C) Operating Voltage: 15—32 VDC Humidity: 10%—93% non-condensing Current Draw(LED on): 6.4 mA max Accessories ,' Operating Current(LED flashing): 750 pA SMB500 4"Square Surface Mount Electrical Boxrl This document is not intended to be used for installation purposes.We try iit . SILENT to keep our product information up-to-date and accurate.We cannot cover MADE IN AMERICA KNIGH' all specific applications or anticipate all requirements.All specifications are II subject to change without notice. For more information,contact Silent FORM#350124 Rev C II Knight 12 Clintonville Road, Northford,CT 06472-1610 ©2013 Honeywell International Inc. by Honeywell Phone: (800)328-0103, Fax:(203)484-7118. For Tehnical Support, Please call 800-446-6444. www.silentknight.com 1 i P' 1, is SYSTEM �� SENSOR^ Indoor Selectable- Output Strobes and Horn Strobes for " # i Ceiling Applications IF . System Sensor L-Series audible visible notification I, ^ i1 products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. a :4 Features The System Sensor L-Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor ' • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. i is at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn L'{, strobes include a variety of features that increase their application 15,30,75,95, 115, 150,and 177 versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA• at 16 volts design with minimal intrusion into the back box,making installations ! • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes,With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. I 6 Agency Listings SIGNALING APPROVED !IMO LISTED S5512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:S03 3057383 l L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- 1- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuif°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. /, Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) )# Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. I AVDS86800 'F UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts ll Candela DC DC FWR 7 I: 15 87 41 60 30 153 63 86 • 1 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 ;:; Temporal Low 96 165 54 71 137 161 185 211 249 £ 1 Non-Temporal High 106 173 71 90 141 165 187 230 273 1 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 I. 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 ,) 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 1 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 ,y 1, 16-33 Volts , FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 1 1' 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 f Horn Strobe Tones and Sound Output Data l Horn and Horn Strobe Output(dBA) I. 8-17.5 16-33 la Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 , 2 Temporal Low 75 83 83 11 3 Non-Temporal High 85 90 90 g 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 1 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 I l AVDS86800 I- l' Li! L-Series Dimensions 2.47 = = 1.37 = = 0 6.92 2.50 06.83 a 1 /.40.07,116.\., liii • 000g _ =. . ... ‘ : . ,,:. „, .....: , CS O 8 \ 1 i .,./ . J Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box l. i r4„11111kl 1 n "• - � 0 1 IL___:401 t n,`)® a J-: t i 1 Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box a if L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 . Universal Ceiling Trim RingRed TRC-2W Universal CeilingRing Trim White SBBCRL Ceiling Surface Mount Back Box,Red tt SBBCWL Ceiling Surface Mount Back Box,White SYSTEM ©2017 System Sensor Product specifications subje m . `) 3825 Ohio Avenue•St.Charles, IL 60174 subject to changewltroutnotice.Veltsystemsensor.co 6-, -Th, SENSOR Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of the data sheet. j AVDS86801•09/17 t 1 w x, ii r t I' �Th SYSTEM ,, �� SENSOR�� iii � I ,. 111111111 Ilillllll F ::' Indoor Selectable- Output Horns, is � *, • Strobes, and �m Horn Strobes for - Wall Applications , System Sensor L-Series audible visible notification t . a ', .1 f 3 " products are rich with features guaranteed to cut " .;, fi installation times and maximize profits with lower 1 current draw and modern aesthetics. *` Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can fj • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs i' • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast i, Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming • 1 ground faults. I{{ • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction j device installation damage,the L-Series utilizes a universal mounting plate for all { models with an onboard shorting spring,so installers can test wiring Electrically Compatible with legacy SpectrAlert and SpectAlert a Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings rSIGNALING 0 LISTED APPROVED hilitiii + S5512 FM approved except 7125-16530504 54011 for ALERT models 7135-1653:0503 1'_ 3057383,3057072 I, r: 1.r= h, 1 :1,'. g� 1 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/a-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 11/2-inch back box.A universal 1; mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications ?' Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing �* Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR12 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) , Input Terminal Wire Gauge 12 to 18 AWG :, Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) .; Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"Lx4.7"Wx1.25"D(143mmLx119mmWx32mmD) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. • UL Current Draw Data '3 s UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) f 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 1 95 N/A 121 155 Non-Temporal Low 29 32 54 ii 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 't 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 75cd 30cd 75cd 30cd 75cd 95cd 110cd 135cd 185cd ;,� Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts ,N, FWR Input 75cd 30cd 75cd 95cd 110cd 135cd 185cd v4 Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 �0 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data . . Horn and Horn Strobe Output(dBA) 8-17.5 16-33 'l Switch Volts Volts li Position Sound Pattern dB DC DC FWR 11 1 Temporal +` High 84 89 89 2 Temporal Low 75 83 83 .i 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 ,` 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 *Settings 9 and 10 are not available on the 2-wire horn strobes. i i L-Series Dimensions 1.91 3.46 3.46 1.25 = = 1.25 I/" • � r;tIL— ''',I44,4 Gd7Vi ��; • i , l° • t o 0 rI;0;1e81�101ooaoo / t°°°°°°.�4 � �. °0 °0°0°0°0°0 5.27 Al 5.27 000oo4°0 ° e °oe°e°o°e°o° pm= III °0°B°A°B°°°B° f I'111111111111 `....o-_J 1i1 J 161 t Compact Strobe/Horn Strobe Compact Horn ;i !i 4.70 _ = 1.91 — 4.70 = 1.25 _= 1.25 5.67 surra• ■li .67 7.-TTM,. 'III JL. iao ‘,.,LtA Ill ,, ,....-w,,,— _} Strobe/Horn Strobe Horn . • It L-Series Ordering Information Model 11' Description 11 Model Description :' Wall Horn Strobes Horns P2RL 2-Wire,Horn Strobe,Red HRL Horn,Red P2WL 2-Wire,Horn Strobe,White HWL Horn,Whiter, P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red i, ' P2GWL "*-. 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red Wall Strobes SBBWL Wall Surface Mount Back Box,White SRL Strobe,Red SBBGRL Compact Wall Surface Mount Back Box,Red SWL Strobe,White SBBGWL Compact Wall Surface Mount Back Box,White SGRL Compact Strobe,Red SGWL Compact Strobe,White k r• SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain tB' SRL-SP Strobe,Red,FUEGO 1 SWL-CLR-ALERT Strobe,White,ALERT it Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover 4' All-ALERT models have"ALERT"marking on cover .?' SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 02017 System Sensor. -, -Th, �}' SE/VSORn Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject tochange without notice.Visit systemsensorcom for current product information,including the latest version of this data sheet. www.systemsensor.com AVDS86503.03/17 D t 1� , SYSTEM , , _. SENSOR® :: 1: 1.1 Selectable-Output k Low Frequency Sounder and LowF F 1 F Sounder g R Strobes for Wall E , ) E «" E Applications t R SPECTflert SpectrAlert Advance audible visible notification productstway A N c q . are rich with features guaranteed to cut installation times 1 and maximize profits. i ' P Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of low frequency sounder and low frequency • 520 Hz± 10%square wave tone sounder strobes in the industry.With white and red plastic housings, • Plug-in design with minimal intrusion into the back box dual listed for wall and ceiling mounting,SpectrAlert Advance can • Tamper-resistant construction meet virtually any application requirement. • Field-selectable candela settings on wall units: • 135, 150, 177,and 185 The wall-mount low frequency sounder,and low frequency sounder strobes were designed to address the NFPA 72 sleeping space • Rotary switch for low frequency sounder tone requirements that require a low frequency notification appliance that • Universal mounting plate for wall units operates within frequency range of 520 Hz±10%and is of a square wave tone.Like the entire SpectrAlert Advance product line they • Mounting plate shorting spring checks wiring continuity before include a variety of features that increase their application versatility device installation while simplifying installation.All devices feature plug-in designs • • Electrically compatible with legacy SpectrAlert devices with minimal intrusion into the back box,making installations fast • Compatible with MDL3 sync module and foolproof while virtually eliminating costly and time-consuming ground faults. • Listed for ceiling or wall mounting To further simplify installation and protect devices from construction damage,SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring,so installers can test wiring • 1 continuity before the device is installed. II Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, Agency Listings automatic selection of 12-or 24-volt operation,and a rotary switch , for 520 Hz low frequency sounder tones. 1 i SIGNALING ' 63111-1N ® ® MEA -O_ LISTED APPROVED approved I "I S4011(sou4der) 3047563 MEA452-05-E 7135-1653 0223 i S5512(strobes) 7125-1653:0224 1. 4 I it 1 ;. SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 1 1/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting products.The notification appliance circuit wiring shall terminate at the universal mounting plate. A Also,SpectrAlert Advance products,when used with the Sync•Circuit'"'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150, 177, and 185.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone and have a permanent marking f. , on the housing that reads"low frequency sounder". # Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire ;3 protective service.The low frequency sounder and the Sync•CircuitTM MDL3 Module accessory,if used,shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts(includes fire alarm panels with built in sync).When used with the Sync•Circuit Module MDL3,12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated 1, notification appliance circuit outputs shall operate between 16.5 to 33 volts.If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used,then refer to the compatibility listing of the panel to determine maximum devices on a circuit.The low frequency sounder has an option to switch between temporal three pattern,non-temporal(continuous)pattern and coded t supply within the frequency range of 520Hz±10%square wave tone.The low frequency sounder shall operate on a coded or non-coded power supply. ' Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The sounder shall have an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The low l! frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply.The field selectable tones will sound il within the frequency range of 520 Hz±10%square wave tone. 1 Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three.Also,while operating the strobes,the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall 'i' synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. 1 - Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Frequency Range 520 Hz±10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm L x 119 mm W x 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D li. (142 mm L x 119 mm W x 33 mm D) �; Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D M. Dimensions(SBBR,SBBW) (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D !! (SBBR,SBBW) (145 mm L x 120 mm W x 76 mm D) I Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. t UL Current Draw Data UL Max.Low Frequency Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts + Sound Pattern dB DC FWR DC FWR Temporal 3 High 191 262 138 166 '.v Continuous High 292 384 138 208 Coded High 292 388 153 205 iii UL Max.Current Draw(mA RMS),2-Wire Low Frequency Sounder Strobe,High Candela Range i; 16-33 Volts 16-33 Volts l DC Input 135 150 177 185 FWR Input 135 150 177 185 r ft Temporal 3 277 292 325 344 Temporal 3 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 1 Low Frequency Sounder Tones and Sound Output Data Low Frequency Sounder and Low Frequency Sounder Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR DC FWR DC FWR 1 Temporal 3 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3t Coded 80 80 80 80 80 80 90 90 li t Sounder ratings provided are for continuous voltage as provided by the NAC ' F iii II: I $i li h i • • I: I.. 1 CIl: ' If ;�i; R F i 1 t Y ' r SpectrAlert Advance Dimensions El 4.7 in. ► 2.5 in. ► 14 4.7 in. ► 11.3 incl A I,IIII,I •/ • f 1 cu=m 111 lei 1r---m---),,, [� 6.4 in. ® 5.6 in0 IIII • Nob— ME 2 I t� . LO.n,arm ill Wail-mount low frequency sounder strobes Wall-mount low frequency sounder i! is q x 'f i 44 SpectrAlert Advance Ordering Information Model Description Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe,High cd,Red P2WH-LF 2-Wire Low Frequency Sounder Strobe,High cd,White Low Frequency Sounders HR-LF Low Frequency Sounder, Red HW-LF Low Frequency Sounder,White Accessories SBBR Surface Mount Back Box,Wall,Red SBBW Surface Mount Back Box,Wall,White ', TR-HS Trim Ring,Wall,Red Notes: .f' "High cd"refers to strobes that include 135,150,177,and 185 candela settings. 1HIft: SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 j ©2015 System Sensor. I SENSOR® Phone:800-SENSOR2•Fax:630-377-6495 Productspecificationsifications subject to change withoutlnotice.Visit s this ensor.com for current product information,including the latest version of this data sheet. www.systemsensor.com AVDS16404.1/15 , *Th, ,SYSTEM . SENSOR . li :1 Outdoor Selectable® Output Horns, - Strobes, and Horn Strobes for I Wall Applications SPECTF1ert SpectrAlerl®Advance outdoor audible visible products Atijirmav A. i1V c are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, "r strobes,and horn strobes in the industry.With white or red plastic • Weatherproof per NEMA 4X, IP56 housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application i • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in 1legacy SpectrAlert products temperatures from-40°F to 151°F. 1' • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features i' • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, If 15/75 candela field-selectable settings,including candela,automatic selection of 12-or 24-volt operation,horn tones,and three volume options enable I • Rotary switch for horn tone and three volume selectionsp installers to easily adapt devices to meet requirements. • Horn rated at 88+dBA at 16 volts It= • Rated from-40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate t • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting}mate includes il i' tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before devices are installed,so installers can verify proper wiring without • Plug-in design with minimal intrusion into the back box mounting the devices and exposing them to potential construction ti • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground'faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion.Knock-outs located on the back eliminate the need to drill ti SIGNALING l,, holes for screw-in mounting. Plastic and metal weatherproof back k, CO I I boxes come with 3A-inch top and bottom conduit entries and 3,4-inch 7300-1653:187(outdoor strobes) LISTED MEA 7125-1653188(horn strobes, knock-outs at the back.A screw-in NPT plug with an 0-ring gasket approved 5359 (ostdo r and lent strobes,hums) APPROVED EA Chime strobes) 53593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. i f' ii C ;i SpectrAlert Advance Outdoor Horn, Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit"'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 1. 115, 135, 150, 177,and 185. , l' t. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. b The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for a visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved ., per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with i', Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe t light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Fj Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. (. 4 1l 4 i AVDS01201 ll'i'''''' UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 6 4 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts I Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR II Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 i` Range 30 NA NA 94 96 Temporal Low 38 44 44 48 ii 75 NA NA 158 153 Non-Temporal High 57 56 69 75 ° li 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 • ' UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) ' 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 i Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 i Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input i; Temporal High 136 155 88 97 112 168 190 210 218 ii p; Temporal Medium 129 152 78 88 103 160 184 202 206 g Temporal Low 129 151 76 86 101 160 184 194 201 r Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 i Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 '. 262 Candela Derating Horn Tones and Sound Output Data i For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) candela ratings must be reduced in accordance with 8-175 16-33 24-Volt Nominal is this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd)ll Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 "! 30 4 Non- High t 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal li 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS0121 i r- I. i' , 3I • SpectrAlert Advance Diagrams ' 1.----4.7" 2.5'=--. I 41--------------------‘---...-7---- .4"--, \ in 5.6" I 1 #, p /I i o r )1Ir' ....,,.___ i,=i7, 1=7,L, _Ij $ ._. _.,__.11� • ii Wall-Mount Horn Strobes `��^7� Wall Plastic Weatherproof Back Box t .., 9 .1 i Q 1 - ®ra0 i :� /11 I jllu II �. I tri _ /II Nil Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information _' Model Description +w' Wall Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK"t 2-Wire Horn Strobe,High cd, Red,Outdoor(includes plastic weatherproof back box) ik P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) It' P2WHK't 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) I Wall Strobes SRK`t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe,High cd, Red,Outdoor(includes plastic weatherproof back box) SWK`t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. i "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 1 candela settings.When replacing standard outdoor units both the device and back box must be replaced. ` � 3825 Ohir: /STEM ©2012 System Senso,. ,, Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change wt out note.vsm t systemsensotco' ��SSENSOR Phone:800-SENSOR2•Fax:630-377-6495 for current productlnfon-aion Includingthe Iatooi ooro,orr of I his dote shoot. t AVOS012C1•3/12 .4 4