Loading...
Report IS.Q.0'g-" ©0113 s 13.195 Ili t ;6,c\NeL- if Fire Protection Services, Inc. 9950 SW Arctic Dr I Beaverton Or,97005 D Phone: (503) 590-3732 scl, 3-\ lij qg 0 Fax: (503) 628-6214 � l River Terrace East Condos 13265 SW 169th Avenue RECE '%'Efl Sherwood, Oregon 97140 FIRE ALARM DESCRIPTION SEP 2018 i i Y OF TIGARD w'' GVI sI O N 5' DESCRIPTION 3 An automatic fire protection system will be installed utilizing an addressable control panel. This will provide for monitoring of sprinkler control valves, flow switches, a single Pull station in the riser room, and an annunciator keypad at the main entrance. The interior room LF horns will be mounted at 84"to the bottom of the device or on the ceiling. The pull station will be mounted at 48"to the center of the device. 1 All audible devices will sound in the ANSI temporal pattern. Primary power to the panel shall be 110 VAC utility power with a 12VDC 7aH battery back-up. All fire alarm circuits will be wired with 16 gauge Fire Alarm Cable with the exception of NAC circuits, which will be wired with (minimum) 14 gauge Fire Alarm Cable. Monitoring will be provided through Alarm Central Station, A UL Listed Monitoring Company in Beaverton, OR. (503.641.6761) q All installation will be done according to NFPA 70 &72 standards. Work will be performed in a neat and professional manner. All work will be performed according to the ,. timeline set. All equipment will be UL listed and approved for the application. SYSTEM COMPONENTS . Silent Knight 5820x1 Addressable Fire Alarm Control &Communicator Silent Knight SK Series Smoke Detectors and Heat Detectors Potter PSN 106 Distributed Power Supplies Silent Knight Addressable Relay Modules { System Sensor Horn Strobes/ Strobes System Sensor LF Horns j' _ Global Project Values: SI LENT Project Name:'River Terrace East Condos I Standby Hours:I 24 I KNICI IT Project ID: I Alarm Mins: 5 Prepared By:ID Phipps I Derating Factor: 1.2 5820XL Calculations Date: 8/29/2018 I Voltage Drop Warning Threshold%:I 10 P Version 12 30.10 Panel ID:15820XLModel: 5820XL Add.Fire Alarm Control Panel Max NAC Current: 3.0 Amps Location: FLOOR 1 ELEC ROOM Volts: 24 VDC Max Panel Current: 6.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Ckt.# Circuit Name Qty Standby Alarm &Type 1000 Ft. One-Way Ohms EOL 5820XL 5820XL CTRL Panel 0.215 0.385 SK Photo,Photo-T 5 0.001 0.001 SK Ion 0.000 0.000 SK Heat,Heat-HT 1 0.000 0.000 SK Heat ROR 0.000 0.000 t SK Beam,Beam-T 0.000 0.000 SK Duct 0.000 0.000 SK Acclimate 0.000 0.000 SK Control 0.000 0.000 SK Control-6 0.000 0.000 SK Relaymon 0.000 0.000 SK Monitor, Minimon 5 0.002 0.002 SK Monitor-2 4 0.003 0.003 SK Monitor-10 0.000 0.000 SK Pull-SA, Pull-DA 2 0.001 0.001 SK Relay 5 0.001 0.001 SK Relay-6 0.000 0.000 SK Zone 0.000 0.000 SK Zone-6 0.000 0.000 SK Isolator Module 0.000 0.000 SSB224BI Isolator Base 0.000 0.000 B200SR Sounder Base 0.000 0.000 SSB224RB Relay Base 0.000 0.000 SSRTS151 Magnetic Remote Test 0.000 0.000 SSRTS151KEY Key Activated Test 0.000 0.000 SSRA100Z Remote LED 0.000 0.000 5815XL SLC Loop Expander 0.000 0.000 5860 LCD Remote Annunc 1 0.020 0.025 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 5865-4 LED Annunciator(4G) 0.000 0.000 5865-3 LED Annunciator(3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 PGM-I/O#1 Notification Appl Circuit 0.000 0.705 #14 Solid 2.52 132 0.67 19.93 2.30% PGM-I/O#2 Notification Appl Circuit 0.000 1.296 #14 Solid 2.52 165 0.83 19.32 5.28% ' PGM-I/O#3 Notification Appl Circuit 0.000 0.744 #14 Solid 2.52 144 0.73 19.86 2.65% PGM-I/O#4 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 165 0.83 20.40 0.00% PGM-I/O#5 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% PGM-I/O#6 Notification Appl Circuit 0.000 0.176 #14 Solid 2.52 45 0.23 20.36 0.20% Total Standby Current(Amps) 0.244 3.340 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Required 5.844 0.278 Total Alarm AH Required Total Combined AH Required 6.12 Command Shortcuts Multiply By The Derating Factor 1.20 Configure Circuits Print Page ` Minimum Battery AmpHours Required 735 17ah Batteries used 0 v ios litIt 1.N.r i 1i N.IGIIr Circuit Configuration Proje n orma ion j. Project Name: River Terrace East Condos Project ID: 0 Prepared By: D Phipps Date: 8/29/2018 Ckt. Number: PGM-I/O#1 Panel ID: 5820XL; ,: , ..,_ .. Ckt. Name: Notification Appl Circuit I/O Use: Notification App!Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 Systemq Sensor H-LF Low Freq. 0.000 0.138 0.000 0.276 3 System Sensor L Series Horn Strobe Wall(30cd; 0.000 0.074 0.000 0.222 1 System Sensor L Series Horn Strobe Wall(75cd; 0.000 0.121 0.000 0.121 1 2 System Sensor L Series Strobe(15cd) 0.000 0.043 0.000 0.086 0.000 0.000 Totals 0.000 0.705 Ckt. Number: PGM-I/O#2 Panel ID: 5820XL\ ;, o Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 9 System Sensor H-LF Low Freq. Sounder 0.000 0.138 0.000 1.242 Y 1 System Sensor L Series Horn Strobe Wall (15cd 0.000 0.054 0.000 0.054 Unused 0.000 0.000 0.000 0.000 r Unused 0.000 0.000 0.000 0.000 0.000 0.000 il Totals 0.000 1.296 f ; Ckt. Number: PGM-I/O#3 Panel ID: 5820XL i Ckt. Name: Notification Appl Circuit I/O Use: Notification App!Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 System Sensor H-LF Low Freq. Sounder 0.000 0.138 0.000 0.690 1. 1 System Sensor L Series Horn Strobe Wall (15cd 0.000 0.054 0.000 0.054 ! Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.744 1. El 5111?N"1' hN1'.11"r Circuit Configuration 'rode n orma ion - it 1 Project Name: River Terrace East Condos Project ID: 0 Prepared By: D Phipps Date: 8/29/2018 Ckt. Number: PGM-I/O#4 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit v Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 _Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: PGM-I/O#5 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit N. Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 _ 0.000 0.000 Totals 0.000 0.000 Ckt. Number: PGM-I/O#6 Panel ID: 5820XL ir Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit • lQty Device Current Draw Each Current Draw Total I 1 System Sensor Outdoor Horn Strobe(75cd)) Standby Alarm Standby Alarm0.000 0.176 0.000 0.176 ii 0 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.176 f;, I P POTTER Project Name: River Terrace East Condos Standby Hours: 24 The Symbol of Protection Building D Alarm Mins: 5 ' PSN-106 Installed By: Batt Efficiency%: 80% Battery& Voltage Drop Designed By: Calculations Date: 8/29/2018 NAC Source Voltage: 20.4 1 Model#: PSN-106 Max Panel Current(amps): 10 Panel ID: Location: Basement Riser Room User assumes all responsibility to ensure the quantities and current draw values in this worksheet are accurate prior to submittal. Panel Standby(amps) Alarm(amps) Qty Part# Description Each Total Each Total i'` 1 PSN-106 NAC Power Expander 0.075 0.075 0.075 0.075 4 Panel Standby: 0.075 Panel Alarm: 0.075 1l NAC Circuits(See NAC Configuration below) Standby(amps) Alarm(amps) ;F Ckt Use Description Total Total 1 0.00000 1.36300 2 0.00000 1.36300 3 0.00000 1.36300 4 0.00000 0.00000 5 0.00000 0.00000 6 0.00000 0.17600 , AUX 0.00000 0.00000 NAC Standby: 0.00000 NAC Alarm: 4.26500 -. Battery Calculation Summary Standby(amps) Alarm(amps) Panel Current: 0.07500 0.07500 • NAC Circuit Current: 0.00000 4.26500 Total Standby: Total Alarm: Standby Hours: 24 Alarm Mins: 5 AH Required: 1.80 AH Required: 0.37 Total Combined Standby&Alarm AmpHours Required: 2.17 Efficiency Factor: 80% Required Battery AmpHours: 2.71 i~`, Battery AmpHours Provided: a i f; ,l T "r i, 1, • 1 Potter Electric Signal(C)2011 1 of 4 PSN-1000(E)Battery and Voltage Drop Calculation 1 } k POTTER NAC Circuit Configuration& Voltage Drop River Terrace East Condos 8/29/2018 NAC 1 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage:1 Description: VN%4 '\s , V pe Ohms/S000ft Length 1-Way ActaiWts Max Load(amps) Volts @ EOL n r n a s #14 Solid 2.5 0.000 1.363 20.40 16 ��c . .,,.,, e��\ Circuit Devices Standby(amps) Alarm(amps) ity S Lookup Type Description Each Total Each Total �, 9 User Defined System Sensor H-LF Low Freq.Sounder 0.000000 0.000000 0.138000 1.242000 MIIIIIIIIIIIIIIIIIIIIIIIII ©User Defined System Sensor L Series Horn Strobe Wall 0.000000 0.000000 0.121000 0.121000 ME Mill- - -- - -- - - Total Standby: 0.00000 Total Alarm: r:' NAC 2 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: { i Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL �,z �` � ), #14 Solid 2.5 0.000 1.363 20.40 16 Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Description Each Total Each Total 9 User Defined System Sensor H-LF Low Freq.Sounder 0.000000 0.000000 0.138000 1.242000 1 User Defined System Sensor L Series Horn Strobe Wall 0.000000 0.000000 0.121000 0.121000 _ Total Standby: 0.00000 Total Alarm: 1.36300 i p: w t Potter Electric Signal(C)2011 2 of 4 PSN-1000(E)Battery and Voltage Drop Calculation 4 Porro NAC Circuit Configuration& Voltage Drop(cont'd) River Terrace East Condos 8/29/2018 1' NAC 3 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL Min Volts Req'd #14 Solid 2.5 0.000 1.363 20.40 16 '- V Circuit Devices ��,�,�� t Standby(amps) cs4�o°` Alarm(amps) Qty Lookup Type Description „ Each Total " Each Total 9 User Defined System Sensor H-LF Low Freq.Sounder 0.000000 0.000000 0.138000 1.242000 0 User Defined System Sensor L Series Horn Strobe Wall 0.000000 0.000000 0.121000 0.121000 111. - - Total Standby: 0.00000 Total Alarm: NAC 4 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: Wire T, j Ohms/1000ft " Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL Min Volts Req'd L #14 Solid 2.5 0.000 0.000 20.40 16 " teuit Devices \r ,• „,. "' Standby(ampsT)otal .,. .,, 'Each E achAlarm(am(amps) QtY tvr Lookup Type .. cription Each Total Total Standby: 0.00000 Total Alarm: 0.00000 ( 't. Ls' zt'-- .r tr: Potter Electric Signal(C)2011 3 of 4 PSN-1000(E)Battery and Voltage Drop Calculation NAC Circuit Configuration& Voltage Drop(cont'd) River Terrace East Condos 8/29/2018 NAC 5 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 '4, Usage: Description: ) Wire Type Ohms/1000ft Length 1-Way Actual Ohms' Max Load(amps) Volts @ EOL Min Mm Volts Req'd iI' #14 Solid 2.5 0.000 0.000 20.40 16 s a4 .�yak.s@ \ \�� �Rr "� Circuit Devices � � Standby(amps) :� � Ala , ys) " � , Qty lookup Type Description , ;;.,,, Each �� Total �' Each Total i Total Standby: 0.00000 Total Alarm: 0.00000 NAC 6 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: x o V {Hire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL as�,, u ft� #14 Solid 2.5 0.000 0.176 20.40 16 Circuit Devices Standby(amps) � Alarm(amps) , Qty Lookup Type Description Each Total Each T .4. ©User Defined System Sensor L Series Outdoor Horn St 0.000000 0.000000 0.176000 0.176000 MI ME OM MIN --� Total Standby: 0.00000 Total Alarm: 0.17600 i. AUX Power MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 V" Usage:I Description: {. l Wire TypeNVIV Ohms/1000ft Length 1-Way A tual Ohms Max Load(amps) Volts @ Last Device ' mwysitotorm 1,1 #14 Solid 2.5 0.000 0.000 20.40 16 i, Circuit Devices Standby(amps) Alarm � ) 4ty Lookup Type Description ° Each Total Each Total a �,x,.r iMI. 1 1.11 MI 11111 ' 111. IM -_-_ ' i� Total Standby: 0.00000 Total Alarm: 0.00000 4i P Itage Drop Calculation it I< INTELLIKNIGHT FIRE ALARM CONTROL PANEL SILENT IntelliKnight® Model 5820XL KNIGHT Addressable Fire Alarm Control System by Honeywell The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKni ht 5820XL is the first fire alarm system to provide you with revolutionaryvalue andin 9 Y ,1 addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed i intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel 9 (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling _ line circuit expander, 5824 serial/parallel printer interface : ..:, module (for printing system reports), and 5895XL intelligent .• ,' power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring ,., location. Features ,I • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using .,. System Sensor protocol • Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. —^' • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • Built-in synchronization for appliances from AMSECO®, • 6 amp power supply and maximum Gentex®, Faraday, System Sensor, and Wheelock® charging capacity of c5 amphoursrequired cabinet enclosure is required for • FlexputTM I/O circuits batteries in excess of 18 amp hours) • Supports Class B (Style 4) and Class A(Style 6) configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • Built-in annunciator with 80-character LCD display The 5820XL can be surface or flush • RS 485 bus provides communication to system accessories mounted • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility `I • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit (SLC) uploads/downloads supports multiple device types of the same $ • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK (System Sensor) • Plex-1 door option combines a dead front cabinet door with a SD clear window, limiting access to the panel while providing • single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FACP. g` INTELLIKNIGHT FIRE ALARM CONTROL PANEL } IntelliKnight Model 582OXL Addressable Fire Alarm Control Panel Indicator Lights 5820XL features a 6 amp power supply required to start a new system.The General Alarm (Red): Flashes when in and maximum battery charging built-in keypad and 5860 remote alarm; solid when alarm silenced capacity of 35 amp hours.An additional annunciator give on-site access to all 71 cabinet enclosure (PN RBB) is required programming.You can also program ,, Supervisory(Yellow): Flashes when a P rY( ) for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when supervisory silenced Flexput circuits on 5820XL control can Software Suite,which is Windows° be individually programmed to function based software. System Troubles (Yellow): Flashes as notification circuits, auxiliary power when a trouble condition exists; solid outputs, or initiation circuits that Built-In Digital Communicator when trouble silenced support both 2-and 4-wire smoke detectors. 5820XL features a built-in UL listed System Silenced (Yellow): On when an digital communicator for remote The 5820XL system operates on non- alarm, trouble or supervisory condition reporting of system activity and system r has been silenced but not yet cleared twisted, unshielded cable when wired programming.The communicator has r in compliance with standard wiring System Power(Green): Flashes for AC practices as called out in the National the ability to seize two telephone lines failure; solid when power systems are Electric Code 760-51 specifications for to report alarms and troubles to a normal power-limited fire protective signalling monitoring facility.The communicator I cables. No special wiring is required. supervises two phone lines and will 5820XLprovides 13preset notification activate a trouble signal if a line failure System Application is sustained for more than 45 seconds. `� 5820XL has one built-in signalling line cadence patterns (including ANSI 3.41) Other communication features include: t circuit(SLC)which supports multiple and four user programmable selections retry if communication fails, two phone I devices dependent on protocol being for fire alarm notification. number capability, download phone used.Three additional loops can be Two programmable general purpose number capability and Touch-Tone or added using the 5815XL SLC Form C relay outputs are provided on rotary dialing. The communicator is expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco _ Additionally,the IntelliKnight system Contact ID.The format is selectable by The 5820XL SLC loops support features a built-in walk test and auto- account number. multiple device types, including: programming. Its innovative, dead-front • Addressable photoelectric smoke cabinet design allows for flush or detector surface mounting. System maintenance • Addressable ionization smoke is easy to perform. detector VO User Interface • Addressable heat sensor The 5820XL built-in annunciator with i, • Addressable duct smoke detector 80 character LCD display and large • Contact module easy-to-use tactile touchpad can be to ; p"` ,: used for system operation, -"--" tar or tat !` • Relay output module programming and maintenance. It has yaw if ter. • Addressable notification module five LEDs for alarm, supervisory, '' • Addressable beam detector(SK system trouble, system silenced and 1' protocol only) system power. System operations Li include silencing alarms and troubles, • Addressable multi-criteria smoke Approvals detector(SK protocol only) resetting alarms and the display of NFPA 13, NFPA 15, NFPA 16, alarm troubles and memory.The NFPA 72: Central Station; Remote ,? • Addressable multi modules (SK system's non-volatile event history Signalling; Local Protective Signalling protocol only) buffer stores 1000 events for viewing from the built-in or remote annunciator. Systems;Auxiliary Protected Premises The following advanced sensor Unit; &Water Deluge Releasing capabilities are available with 5820XL: System operation can be initiated with Service. Suitable for automatic, a mechanical firefighter's key or a valid manual,waterflow, sprinkler • Automatic drift compensation 4-to 7-digit operator's code. supervisory(DACT non-coded) • Maintenance alert Programming signalling services. • Built-in sensor test to comply with The IntelliKnight system offers several Other Approvals: UL Listed; NFPA 72 calibration testing options to simplify and speed up CSFM 7170-0559: 135; requirements programming. The JumpStarto feature MEA 429-92-E Vol.VI; FM Approved f minimizes programming #: I' t i IINTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel IntelliKnight 5820XL "`°� Based Addressable Fire Alarm System ManagementSoftware SK(System Sensor) Protocol Devices lllindows Based Up/Download 9 Software In' i U Ir. T Compatible CS 1. p®_..�: .ea Receiver t r-�El RC 2J2 I •utomation r. Sol I! 1 ftwarete et l �- 5820X1. SK-2/2U Connection UsorAlarm IP Communicator 1 5885X1. i9.' rvauna.RJ..,,rM..d,n 3FumCPnays n 4 3,em RWav- 4 - —� ' EYeIdr P,lnle w r _ 5815XL $ 4. IRS-Es2 IE Lc,Exx do 5860 5826 : �� "emote nrnuncotor Prrtcn camm�m hbdula e h �h$ } T l t,llv:::;JstNrr) ., i :, 6 Fla�ut" ae I/O Circuitss. '' 5XL _ can be inputs ', I 581'Fcende- or outputs Q a --6 Flenput• **. 110 circuits 1 F can be Inp .:+ m ' or outpuh g: ,4 4......] E n1 Eel,Etrotee Y0,5 and NA_: P v'. ct ` ) • F,1 SAl'Am a � sm ItVrl[rt ♦♦ l tA., _ 111.1 BK4on SK•abretor 8Kdso SK-CoMol.6 SK-Control B2008R SK•Acdlmate SK.2ane-6 ';S+e tddroat3Cl0 Add-sse8613 Fault soletx .4.^u0ensaBE SJrer.isod :nun der Idutcrtene Zcre 101111�v Mndule iH!rlca�on (141101 Bane st rA,o Ince boo 1�e,r 5666 :e[eC[cr MJtluJ moat) MCdUa tlOtactCr \10710 nen`ote Arnun:atcr MI „, 10 SK•Photo 8K441onttor•2 SK-Releymon-2 SK-Heat 82246E 822481 B210LP 6KPhoto-T .0 al Montor Add•os1et10 OK-Heat-ROR Rslay Ntse., mono . 5880. Ai Ird.+sn.'.. Mceule Cut.Monitcr case Base_ .se LE_1/...100& Fhoted0¢nc Co/ram R''' SKHnn00e FF Ira Modue M Bade F Ceteeta Hc+et 0,a.twe 10 i # II I iii , _ ,d , r i WI 5883 'tna �r I Rdm llu.r..Mo ul. SK•Beam SKMon-10 OK-Pull-DA 0K-Ouct SK-Mdmon SK-Relay-6 SK•2one SK-Relay OK$Eare•T Ad?o;1:tl0 OK-Pull-SA A7T%`erle Molter Peas(017c1 Ad?reentla Adtaaaat/) Acre CaWc M I Al li.st.Clp Du Moculc Maul n.erte_e Rant/ Nan nste-In, Modue P.IIStation n4.„n1 1/0(11 t, Molle . 0337MMI r -1 5885-4 or 5865-3 I Use the 5880 to control upto 4 I EDAnnc 1 tan- I r— �r,.65.4 vto - I 5883 Relay Interface Modules I NV I. INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL + Addressable Fire Alarm Control Panel Specifications S-BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz,2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using Total Accessory Load: 6A @ 27.4 VDC, and 5860R is red. a PC. Upload and view panel account power-limited 5815XL Signal Line Circuit Expander information, event history, and detector Standby Current: 215 mA The SLC expander is used to add more status. Alarm Current 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system. 5820XL supports three (SKSS) Flexput Circuits: 5815XL's. Each 5815XL can support 99 Powerful end-user facility management ' Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector programmed individually as: 127 SD devices. status and event history via modem or Notification circuits: 3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power, 6 Flexput I/O Plex-1 Auxiliary power circuits: 3A @ 27.4VDC circuits and 2 Form C relay circuits to a Dead front cabinet door with clear per circuit, power-limited 5820XL system. window to limit access to the FACP. Initiation Circuits: 100 mA @ 27.4VDC 5496 Intelligent Power Module RBB per circuit, power limited A 6 amp notification power expander Remote battery box accessory cabinet. that provides four power-limited notifi- Use if backup batteries are too large to i Physical cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 16"W x 10" H x 6" D 5880 LED/10 Module 14.5"W x 24.75"H x 3.9"D Features 40 LED outputs, 8 normally (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs, and one piezo SD505-DTS-K s output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR. Provides remote key _ 16.2"W x 26.4"H x 4.2"DRemote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) Features 30 programmable LED (15 of detector alarm. red and 15 yellow)outputs, and a piezo SD and SK Devices Weight: 28 lbs. (12.8 kg) sounder.The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7.0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet. Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log FCC Part 15 and Part 68 approved of system events, detector status Type of Jack: RJ31X(two required) reports, and event history. Interfaces twith building control system. rila SILENT This document is not intended to be used for installation purposes.We try to keep our Made in America KNIGHT product information up-to-date and accurate.We cannot cover all specific applications or anticipate at requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472 PN 350210 Rev H2 by Honeywell Phone:(203)484-7161,Fax:(203)484-7118.www.silentknight.com. ©2012 Honeywell International Inc. IntelliKnight&JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight i • { INTELLIKNIGHT ACCESSORY itSILENT 5860 Remote Annunciator 4 KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every yrf , area within your facility 4 Now you can operate and program your IntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. I r Description • Available in red or light gray Features include an 80-character • Support for simultaneous use of 31 backlit LCD providing easy-to- multiple 5860s `! understand system messages. The • RS-485 interface to panel annunciator is ergonomically • Operation and appearance `x p is w° designed with over-sized buttons identical to 5860 built-in s for the most frequently used annunciator > D t features, like Reset and Silence. • On-board piezo sounder audibly In addition to status messages indicates alarms, troubles, and . A ; tt 11 INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator Engineering Specifications tThe main control must have a built-in annunciator and must support up to 12 remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. ii Remote annunciators shall have identical functionality and operation as the built-in annunciator.All annunciators li must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System li Trouble, System Silence, and System Power. I !i All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a I travel of.040 inches. No membrane style buttons will be permissible. .1 The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP H ii M j ' 44 ,askitt4 int*OA r SBUS 0 � i li 5860 5860 5860 • Up to 12 5860s Per IFP-100/ECS or IFP-1000/ECS System •Up to Eight 5860s Per 5700 System ICompatible IntelliKnight FACP Listings Ordering Information NFPA 72; UL Listed; 5860R Remote Annunicator four line LCD CSFM 7170-0559: 135; annunciator with 20 characters per line. MEA 429-92-E Vol. IX; Red FM Approved 5860 Remote Annunciator four line LCD 1 annunciator with 20 characters per line. t Gray ,, q Accessories 0 5860TR Red Trim Ring for surface mounting t 5860TG Gray Trim Ring for surface mounting 1 F 4 i SILENT This document is not intended to be used for installation purposes.We try to moc keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information,contact Silent Knight Nomemomiramilinim by Honeywell 12 Clintonville Road,Northford,CT 06472-1610. Phone:(800)328-0103, mmisINIIIIIIIIMIi Fax:(203)484-7118.For Technical Support, Please call 800-446-6444. www.silentknight.com Assembled in America . 1 ,' 1 P POTTER PSN SERIES - 0 The Symbol of Protection POWER SUPPLY 1: UL,cUL,CSFM Listed • PSN-64 has 6 amps regulated with 4 Outputs • PSN-106 has 10 amps regulated with 6 Outputs '.1"I • Outputs Rated at 3 amps maximum each 0 ��� tt • May be configured as up to three class"A"Style"Z"notification circuits �""c • 3 amp,24 VDC programmable output power 0 • Supervised Battery Charger:27.3 @ lA(supports 7-55 All batteries) • Easy to install cabinet with leveling mounts and key lock • Wiring knockouts provided on sides and top of cabinet • Two Trouble Relays(5A at 30VDC) ® General System Trouble(programmable for AC delay) Low AC Trouble with optional delay settings • Diagnostic LED's patent pending Status LED's for Active NAC and NAC trouble conditions Status LED's for Earth Fault(Amber),AC(Green),Battery Fault(Amber) ,,, • Trouble Memory feature captures troubles which have previously restored C®US a' • Synchronized notification appliance circuits LISTED iWit i Potter/AMSECO®,Wheelock®,Gentex®,System Sensor® S2930 7315-0328:0189 • Configurable output circuits(DIP switch sets options for each circuit) • 15 mA at 8-33 VDC input trigger Product includes a 5 year warranty • Reference EOL allows 2K—27K EOL value to be used • Quadrasync provides panel wide synchronization of same or multiple brands Dimenions: 16 1/8"W x 16 3/4"H x 3 1/2"D • PassThru mode allows the Outputs to match the Input Signal Electrical Specs: Stock Number:3006436 PSN-64 Red Enclosure • 120/240 VAC 50-60 Hz input 3006437 PSN-106 Red Enclosure • 5.1 Amps @ 120 VAC or 2.5 Amps @ 240 VAC 1 3006446 PSN-106 Black Enclosure • Standby Current 60 mA i • Alarm Current 200 mA* I *no external load Description The PSN series of notification power supplies offers reliable notification Sensor®strobe devices.Each output can be configured the same sync t+ power with unprecedented versatility.The power supplies offer either protocol or set independently. 6 or 10 amps of continuous power through 4 or 6 outputs respectively. In addition,the panel has an input PassThru mode allows the outputs Each output is rated at 3 amps and it may be used continuously without to follow the input signal and sync up the input flash. The panel will any derating. recognize the type of input being supplied and pass this through to the The power supply operates on either 120 VAC or 220 VAC power input outputs with the same pattern.This input pass through can be selected ," and has a regulated 24 VDC output.In addition,the panel can charge on each output independently. up to 55 AH batteries and leads the industry in housing up to 18 AH The power supply contains simple dipswitch programming and LED batteries.The cabinet is constructed out of 18 gauge cold rolled steel and indications providing the installer indications of the operation and the has a durable red powder coat finish.In addition,a key lock is provided ability to correct any faults.A Trouble Memory is provided to allow an for securing the door.Ample electrical knockouts are provided on the installer to reviewast troubles and make the necessary sides and the top,allowing the installer options for running wires and p repairs.Each maintaining the correct separations. output has an LED to pin point the exact circuit where a problem may have occurred.Relays are provided for monitoring the general system 1', The power supply offers an industry leading Quadrasync function that and AC failure. 1. allows for multiple strobe circuits of different brands to be synchronized Each output and be independently configured for various applications to flash at the same time.The panel can have four different brands each and installations.Each output can be independently configured for Class connected to its'own circuit and all of the strobes flash together. A or Class B operation,constant power,ANSI Temporal Code 3,Single, Each output can independently be configured to provide one of Multiple or Combo Inputs or Door Holder Power. four synchronizations or steady power. This provides unequivocal flexibility in new and retrofit installations.The panel can be configured • to synchronize Potter/AMSECO®, Gentex®, Wheelock® and System Potter Electric Signal Co.,LLC•St. Louis,MO•Cust Service: 866-240-1870•Tech Support: 866-956-1211 •Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8910013-REV C2 PAGE 1 OF 2 11/12 1, !, . . P POTTER PSN SERIES ® The Symbol of Protection POWER SUPPLY PSN-106 Wiring Diagram 120/240 VAC GND FAULT ,-,1 _ Jumper Position DETECT ENABLE ONI 1nI OFF 120VAC 50Hz-60Hz 240VAC 50Hz-60Hz Black Connect to separate White unswitched AC circuit Ground staves LED's NAC1 NAC2 NAC3 NAC4 NAC5 NAC6 DCPWR IO I L. -�' 40A. 0• • • • • • • •S7 'SS O % � *Ng Naga* — , kit ❑ o o(aaaaatisl H N comm• Fuse 4,1 II I o II'I'I'I'I'isz CD El Lel o Iaaaaaais3 ❑ ❑ ❑ o iL l j WI ❑ ❑ 0 D © L \ al0 ❑ ❑ o IaeaUUUlS4 Factory Installed Interconnect. O Iaaaeaals5 AC Power Low Battery 0 God Fault I I I I I I O laaaaaals6 8 Comm Rp D VIII O Bulk Options II r�^,Il^`,7,I 7-15,7, 0 I I rd ii"j 1,_ a 13_ ,1 1_ :9:l�-ZAil E1- illlI w-.: L LIC l 10 1_ .,,,,_:.....J....., laic O I!NAC+ NAC+2 NAC+3 NAC+4 + NAC+6 /OCP+' REnF[ A1N2 O LOW AC TROUBLE f FM - +AOI RELAY RELAY • NC COM NO NC COM NO ,11SCk Battery+ P I 1 j Cmnrelays are "/--�- ' Buttery- j L.,..,-;Optional E O.L o porelimited. ./ Referee. EoL. i \ 11 DC Power Tngger - + Note:PSN-64 and PSN-I06 draw 15 mA when polarity reverses and the power Battery connection(non-power 13mitea). Use two(2)12V batteries connected In seriessupply is triggered.There is no current draw in Standby Mode. ' Engineering Specification The contractor shall supply and install the Potter PSN power supply.The assemblies.The LEDs shall have distinct flash patterns to provide further power supply shall operate on either 120 or 240 VAC input.The panel indication ofthe troubles present.The panel shall have selectable Trouble shall be capable of continuous load power without any degradation to Memory to provide the installer an indication that a past trouble existed the main supply or the distribution board.The cabinet shall be capable of on a circuit for diagnostic purposes. housing up to 18 All batteries and the panel shall be capable of charging Each output of the power supply shall be capable of 3 amps of continuous up to 55 AH batteries in an external cabinet. power without degradation over time.The power supply shall provide for The panel shall have dip switches for simplistic configuration of the multiple circuits of strobe appliances.The power supply shall synchronize system and LEDs to provide visual indication to the installer of the status the flashes of any of the above listed strobe appliances on a per circuit of the system.The dip switches shall allow for AC power delay selection, basis.Up to four different strobe circuits may be connected and all of -t Class A/B operation per output,Door Holder Power options,constant the strobes shall flash in unison as required by UL 864.In addition to auxiliary power,trigger input type,ANSI Code 3 Temporal Code,Pass this Quadrasync feature,the panel shall allow any of the four above b. Thru(input tracking),Potter/AMSECO®sync,Gentex®Sync,System mentioned sync patterns as an input and pass this signal through and ' Sensor®Sync or Wheelock®sync.The LEDs shall provide indication synchronize the outputs to match the input flash pattern. i.' of communication between the power supply and distribution circuit PRINTED IN USA MKT.#8910013-REV C2 PAGE 2 OF 2 - 11/12 1 1. INTELLIKNIGHT ACCESSORY l , ItSILENT SK-Photo, SK-Photo-T i KNIGHT and SK-PhotoR by Honeywell Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal q and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description • Optional remote LED annunciator , (System Sensor®PN RA100Z) r; i SK-Photo and SK-Photo-T are plug-in • Plug-in mounting provides ease of type smoke sensors that combine a installation photoelectric sensing chamber with • Tamper-proof feature available on addressable analog communications. mounting bases , Point ID capability allows each ',...: detector's address to be set with rotary • Listed for use in duct applications , address switches, providing exact • Rotary address switches for fast \a, i detector locations for selective installation maintenance when chamber • UL Listed contamination reaches unacceptable • FM Approved 1 levels. SK-Photo and SK-Photo-T have a Specifications unique optical sensingchamber that is • q P Physical engineered to sense smoke produced Height:2.0" (5.0 cm) SK-Photo (Base included) by a wide range of combustion Diameter: 4.1" (10.4 cm)installed in sources. In the SK-Photo-T, dual 6501 base electronic thermistors add 135°F(57°C) Installation thermal technology to maximize Electrical detection. Operating Voltage: 15-32 VDC The SK-Photo and SK-Photo-T plug Standby Current: into a compatible IntelliKnight-series The SK-PhotoR is a remote test detector base. The SK-PhotoR is a capable detector for use with the 300 pA @ 24 VDC Maximum remote test capable detector head DNR/DNRW duct smoke detector. (not Alarm Current: 6.5 mA @ 24 VDC max included within the DNR(W)duct included) (with LED on) smoke detector. Environmental Operating Temperature Compatibility Features SK-Photo: 32°—120°F (0°C—49°C) SK-Photo, and SK-Photo-T are • Sleek, low-profile design SK-Photo-T: 32°—100°F(0°C—38°C) compatible with the following detector • Base included Humidity: 10%—93% non-condensing bases: • Reliable analog communications for Other Ratings 6210LP 6"base(included) trouble-free operation SK-Photo-T Thermal: Fixed B501 2 wire base temperature set point 135°F (57°C) B224RB Relay base • Age resistant polymer housing 822461 Isolator base • Dual electronic thermistor design on Velocity: 0—4000 fpm (0—20 m/sec) B200SR Sounder base the SK-Photo-T The SK-Photo, SK-Photo-T, and SK- Superior EMI resistance for reliability PhotoR are compatible with the • Simple field cleaning for code following IntelliKnight FACPs: compliance 5820XL • Variety of mounting options to meet 5820XL-EVS any application 5808 5700 • Dual LED indicators for 360°visibility 5600 (Rev 2.0 or higher) • • Detector transmits signal to indicate maintenance is required 1;;. 4 I ii INTELLIKNIGHT ACCESSORY Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B210LP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). f The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the is flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. 4 The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. IThe vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. ----- �� SLC IN OUT 3 MX IN 11,, Compatible FACP sk.awaa419 ■ RA100Z(Optional) !I1t 1 %ill i 11411‘11.7 1:111INPOP r t Class A Optional Wiring t Wiring SK-Series Detector Mounting Bases r #; SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA ICNIGIiT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350118 Rev E subject to change without notice. For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support, Please call 800-446-6444. _ www.silentknight.com r INTELLIKNIGHT ACCESSORY - SILENT SK-Heat, SK-Heat-HT ti KNIGHTIli and SK-Heat-ROR by Honeywell Addressable Thermal Heat and :i Rate-of-Rise Detectors The SK-Heat, SK-Heat-HT, and SK-Heat-ROR are plug in thermal detectors, with integral communication, that I. provide features that surpass conventional detectors. These thermal detectors are for use with Silent Knight IntelliKnight series Fire Alarm Control Panels (FACPs). IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Description • Detector transmits signal to SK-Heat, SK-Heat-HT and SK- indicate maintenance is required Heat-ROR are intelligent sensors • Plug-in mounting provides ease that utilize a state-of-the art of installation �� �, � thermistor sensing circuit for fast • Optional remote LED annunciator response. Sensitivity is (System Sensor®PN RA100Z) continuously monitored and • Tamper-proof feature available on reported to the FACP. Point ID mounting bases capability allows each detector's address to be set with rotary • Rotary address switches for fast address switches, providing exact installation SK-Heat (base included) detector locations for selective • UL Listed maintenance when chamber SK-Heat-ROR: Rate-of-rise contamination reaches Specifications detection 15°F/min (8.3°C/min) , unacceptable levels. Physical Compatibility SK-Heat is ^ fixed temperature Height: 2.0" (51 mm) Diameter: 6.1" (155 mm) installed The SK-Heat, SK-Heat-HT and SK- • sensor that uses a thermistor Heat-ROR are compatible with the sensing circuit to produce 135°F in 6210LP base following detector bases: (57°C)fixed temperature alarm. Shipping Weight: 4.8 oz (137 g) Electrical B210LP 6" base (included) SK-Heat-HT is a variable high B501 2 wire base temperature detector that provides Operating Voltage: B224B1 Isolator base high temperature detection at 15 to 32 Volts DC Peak B224RB Relay base 135°F - 190°F. (57°C - 88°C) Standby Current: B200SR Sounder base 300pA @ 24 VDC SK-Heat-ROR is a rate-of-rise The SK-Heat-HT and SK-Heat- temperature sensor with 135°F LED Current: 6.5 mA@ 24 VDC ROR are compatible with the (57°C)fixed temperature alarm. Environmental following IntelliKnight FACP's: Features Operating Temperature 5820XL SK-Heat& SK-Heat-ROR: 5820XL-EVS • Reliable analog communications _4°- 100°F (-20°C—38°C) 5808 for trouble-free operation 5700 • Age resistant polymer housing SK-Heat-HT: -4°— 150°F (-20°C—66°C) The SK-Heat is compatible with the • Innovative thermistor sensing following IntelliKnight FACP's: circuit Humidity: 10%—93% • Superior EMI resistance for noncondensing 5820XL 5820XL-EVS reliability Thermal Ratings 5808 • Variety of mounting options to SK-Heat: Fixed temperature alarm 5700 meet any application 135°F (57°C) 5600 (Rev 2.0 or higher) • Dual LED indicators for 360° SK-Heat-HT: High temperature heat visibility sensor 135°F- 190°F (57°C - 88°C) P/N 350120 Rev. F ©2016 Honeywell International Inc. t INTELLIKNIGHT ACCESSORY • Model SK-Heat, SK-Heat-HT, SK-Heat ROR Addressable Thermal and Rate-of-Rise Thermal Detectors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent Thermal Sensor Silent Knight Model SK-Heat, SK-Heat-HT or SK-Heat-ROR. The base included shall be B210LP. The Heat detector shall have a flashing status LED for visual supervision. When the detector is activated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The Ii locking feature shall be field removable when not required.Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. SLC i IN OUT / a?a Compatible FACP i al + — 111— RA100Z(Optional) I MAI 11, 11 illy 4•=41j1161.-.. MT II° Nilik6 a r(' (4 (4 / Class A Optional Wiring / , Wiring SK-Series Detector Mounting Bases Accessories M02-09-00-Test Magnet with Telescoping Handle. RA100Z-Remote LED Annunciator. XP-4-Extension Pole for XR2B.Extends from 5—15 ft. RMK400-Recessed Mounting Kit.Provides low profile for use with T55-127-000-Detector Removal Head. 8501. i BCK-200B-Black Detector Kit.For SK-series detectors. XR2B-Detector Removal Tool.A removal and re-placement tool for SK plug-in detectors. Includes the T55-127-000. `Unless otherwise noted,specifications apply to all SK thermal detectors. IM02-04-01 -Replacement Test Magnet. j This document is not intended to be used for installation purposes.We try to keep our product information up-to- SILENT lidate and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are _ a NI KNIGHT '` subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. For Technical Support,Please call 800-446-6444. by Honeywell www.silentknight.com la INTELLIKNIGHT ACCESSORY 4% SILENT SK-Pull-SA and SK-Pull-DA lik KNIGHT by Honeywell Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description -- The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual F ' E action pull station requiring two motions to active the station. ,. Both pull stations are designed to work with Silent Knight r I PULL 1 ii Intelliknight series fire alarm control panels (FACPs). i' DOWN Features • Installer can open station without causing an alarm condition SII ENT © 'L. ricer ) • Dual-color LED is visible through handle of station blinks a green to indicate normal operation and remains steady red in an alarm condition SK-Pull-SA t • Key operated test and reset lock using lock plate actuator ,_ _ , • Key matches compatible FACP locks F I • E Meets the Americans with Disabilities Act Accessibility ;;:: Guidelines (ADAAG) controls and operating mechanisms1 PUSH IN tt guidelines (Section 4.1.3[13]) PULLII DOWNi I • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® r, nm ,. a. .,° ) • Reliable analog communications for trouble-free operation a • Braille text on station handle SK-Pull-DA • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled The SK-Pull-SA and SK-Pull-DA are compatible • Rotary address switches for fast installation with the following IntelliKnight FACP's: 5600 • UL Listed, including UL 38, Standard of Manually Actuated 5700 j Signaling System 5808 5820XL 5820XL-EVS w f tl 14 INTELLIKNIGHT ACCESSORY 1 . r Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. r ri q 4/1' a , Class A ue ,' Class B Compatible FACP t 1' 2 136 , 't ®n t tkilii filo ft ft Class A Wiring: r Class B Wiring: ow a e Wiring SK-Pull-SA&SK-Pull-DA Pull Stations Specifications Electrical Operating Voltage: 15-32 VDC Physical Height: 5.5" (14 cm) Average Operating Current(LED flashing): 300 SIA Width:4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32°— 120°F (0°C—49°C) Bi-Colored LED: Humidity: 10%—93% non-condensing Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST)normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-I/O Surface backbox SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover IQVIGHT all specific applications or anticipate all requirements.All specifications are FORM#350135 Rev C subject to change without notice.For more information,contact Silent ©2013 Honeywell International Inc. by Honeywell Knight 12 Clintonville Road,Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com r I INTELLIKNIGHT ACCESSORY } SILENT SK-Relay KNIGHT "' :k„ by Honeywell Intelligent Relay Module The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of each module is seiected using the built in rotary switches. For more information about the IntelliKnight system, or to locate you nearest source, please call 800-328-0103. 4 Description The SK-Relay is an addressable relay module for use t` with Silent Knight IntelliKnight series fire alarm control '' f panels (FACPs). , The SK-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains � ` � �s� �� � � � � two isolated sets of Form C contacts, which operate as a \ "� �°` DPDT switch. No supervision is provided for the �`�� k, � ��� aT" notification appliance circuit. t � , �t'a' ‘ The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK- SK-Relay Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls Installation the SK-Relay, the relay is triggered by the FACP. The SK-Relay mounts directly into a 4" square electrical box. The box must have a minimum Features depth of 2-1/8".A surface mount electrical box • Two sets of Form C contacts (System Sensor® PN SMB500) is available from • Rotary address switches for fast installation Silent Knight • Contacts are rated for a variety of amps (see Specifications) Compatibility The SK-Relay is compatible with the following • Panel controlled status LED that flashes green in IntelliKnight FACP's: normal state and is solid red in alarm 5820XL 5820XL-EVS • Relay programming is completely flexible—can be 5808 mapped to zone conditions 5700 5600 (Rev 2.0 or higher) • Polling LED visible through the cover plate i • Attractive ivory cover plate • SEMS screws for easy wiring P/N 350127 Rev E • UL Listed ©2015 Honeywell International Inc. t INTELLIKNIGHT ACCESSORY I, t . Model SK-Relay Intelligent Relay Module ifi il To Next Device - 41 If Any Wiring to Terminals 3-9 is Not Power + 4111 Limited,the CB500 Barrier is Required.The CB500 Includes a Non-Power Limited Label, n n Which Must Be Placed Over the Power Limited 'O O c ^ Terminal Information on the Name Plate Label. V .)«i Relay Common 2 I I Y . ° MI Normally Closed 2 ttri 8 ::6 + 1,149 Normally Open 2 � ,.'• s � :.' •{ Relay Common 1 � � • $ �_ + From Compatible FACP il , �� or Previous Device r Normally Closed 1 r+ s ' + � �.. V I— Normally Open 1 Module Does Not Supervise (1 Q 0 Controlled Circuits v U U • Wiring the SK-Relay Module . Specifications Ordering Information Physical SK-Relay Relay Module 4.675' Hx4.275" Wx1.4" D Shipping Weight: 6.3 oz (196 g) Accessories SMB500 4" Square Surface Mount Electrical Box Environmental CB500 Module Barrier Operating Temperature: 32°F- 120°F (0°C-49°C) Humidity: 10% -93% non-condensing Electrical Relay Contact Ratings Operating Voltage: 15-32 VDC End-of-Line Resistance: Not used 3.OA @ 30 VDC resistive SLC Standby&Alarm Current: .255mA max @ 24 0.9A @ 110 VDC resistive VDC (one communication every 5 sec with LED 0.9A @ 125 VAC resistive enabled) 0.5A© 125 VAC inductive (PF = .35) 0.7A @ 75 VAC inductive (PF = .35) SILENT This document is not intended to be used for installation purposes.We try to keep ini KNIGHT our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road, iiimmommomminomm by Honeywell Northford,CT 06472-1610 Phone: (800)328-0103, Fax:(203)484-7118. For mionmeimmoommi Technical Support,Please Call 800-446-6444. www.silentknight.com Asembled in USA INTELLIKNIGHT ACCESSORY SILENT SK-Minimon , it% KNIGHT by Honeywell Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight IntelliKnight fire alarm control a panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other i applications requiring dry contact alarm initiation devices. For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. • Description The SK-Minimon is an addressable °'r monitor modules for use with the ° x IntelliKnight fire alarm control panels (FACPs). The SK-Minimon acts as an interface to contact devices, such as waterflow switches and pull stations. ,,,,:::---, f The SK-Minimon supports Class B " H° , - r ri .. supervised wiring to the load kta -a , device. Conventional 4-wire smoke '"`°" • ° detectors can be monitored for ,. alarm and trouble conditions The SK-Minimon can be mounted E�, in a single gang junction box ;, directly behind the monitored 4. device. Its small size and light SK-Minimon weight allow it to be installed without rigid mounting Specifications Compatibility requirements. The SK-Minimon is compatible with Electrical p Features Standby Current: 400 uA max @ the following IntelliKnight Systems: • Single contact monitor 24 VDC with comm. 5820XL • SK-Minimon support for Class B Voltage Range: 15 - 32 VDC 5820XL-EVS (Style B) contact monitor wiring End of Line Resistance: 47 k Ohms 5808 • Small and lightweight size allows 5700 Physical 5600hi 2.0 or Rev higher)ger) for flexible mounting options Dimensions: SK-FFT • Rotary address switches for fast 2.75"W x 1.3" H x 0.5" D installation Weight: 1.2 oz (37 g) • UL listed Environmental Listings Operating Temperature: UL 32°F— 120°F (0°C—49°C) CSFM Humidity: FM 10%—93% non-condensing • INTELLIKNIGHT ACCESSORY SK-Minimon , Intelligent Monitor Module { ; Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. t f. 11 y' c a '-n- ADDRESS ADDRESS 0 ? 1418 t 2 2 12 1 '3 Compatible FACP 11 ' ' 4 1 93 7 r6 LOOP 9 8 7 6 TENS ONES — + + — < two Er aEr a 6 o ii F A- O O O 0 I ►1 I; Other Devices Wiring the SK-Minimon SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate.We cannot cover FORM#350133 Rev E all specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information,contact Silent ©2013 Honeywell International Inc by Honeywell Knight 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY 4% SILENT SK-Monitor-2 KNIGHT by Honeywell Intelligent Dual Monitor Module The SK-Monitor-2 module is capable of monitoring two separate Class B circuits simultaneously, making it ideal for waterflow tamper switch and flow switch monitoring. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Monitor-2 is an addressable monitor module with two initiating circuits for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Monitor-2 acts as an interface to contact devices, such as waterflow switches and pull stations. The SK-Monitor-2 supports Class B supervisred wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. SK-Monitor-2 Installation Features SK-Monitor-2 mounts directly into a 4" • Monitor two circuits, with unique addresses, square electrical box. The box must have t; simultaneously a minimum depth of 2-1/8". A surface • Support for Class B wiring mount electrical box (System Sensor® • Fully supervised part number SMB500) is available from • Panel controlled status LED that flashes green Silent Knight. in normal state and is solid red in alarm Compatibility • Attractive ivory cover plate The SK-Monitor-2 is compatible with the • Rotary address switches for fast installation following IntelliKnight FACP's: • SEMS screws for easy wiring 5700 • UL Listed 5808 • 5820XL 5820XL-EVS INTELLIKNIGHT ACCESSORY Model SK-Monitor-2 1. Intelligent Dual Monitor Module p P To Next Device _ 4 n n 00 ° 0 , Lili �_ „ Ts @9 f,n . (-1 t T6.". Qo Compatible FACP / Two Initiating Device Circuits NFPA Style B u u \\� Power Limited 230 pA Max @ 12 VDC Max SLC n n OUT IN aii_ Ciii2iii ill jc_itiTar�e�»mihITe 17 I �. le..17 ,.. Q o .o O 2] u u I J Wiring SK-Monitor-2 Modules / 1 Specifications End-of-Line Resistance: 47K 1 fli Physical Max IDC wiring resistance: 1,50052 r Height: 4.5" H x 4"W x 1.25" D SLC Line Loop Resistance: 40Q max. Shipping Weight: 6.3 oz(196 g) Environmental Electrical Operating Temperature: 32°F— 120°F (0°C—49°C) , Operating Voltage: 15—32 VDC Humidity: 10%—93% non-condensing `` Current Draw(LED on): 6.4 mA max Accessories Operating Current(LED flashing): 750 pA SMB500 4"Square Surface Mount Electrical Box This document is not intended to be used for installation purposes.We try MADE IN AMERICA SILENT to keep our product information up-to-date and accurate.We cannot cover 1KNIGH' all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent FORM#350124 Rev C Knight 12 Clintonville Road, Northford,CT 06472-1610 ©2013 Honeywell International Inc. by Honeywell Phone:(800)328-0103, Fax:(203)484-7118. For Tehnical Support, Please r call 800-446-6444. www.silentknight.com Th_, SYSTEM - SENSOR' Indoor Selectable- 1NATa Output Strobes and , ~ t Horn Strobes for w+_� f Ceiling Applicationsif System Sensor L-Series audible visible notification products are rich with features guaranteed to cut "ti installation times and maximize profits with lower current draw and modern aesthetics. it' Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry t` with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela i" The entire L-Series product line of ceiling-mount strobes and horn • Field-selectable candela settings on ceiling units: i' 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring, installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, r', automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings 11. SIGNALING LISTED APPROVED flail S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383 I 1 L-Series Specifications Architect/Engineer Specifications _ General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1'/cinch back box,4-inch octagon back box,or double- ' gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used it for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series . products,when used with the Sync•Circuit°'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe • shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination • The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act • requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service,The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. • Physical/Electrical Specifications ' Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) .i, (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. 4 4 f AVDS86800 N UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 f� 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 i UL Max.Current Draw(mA RMS),2-Wire Horn Strobe ;' a 8-17.5 Volts 16-33 Volts DC Input 75cd 30cd 75cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 ;1 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 75cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 ;z-G 3.1 K Non-Temporal High 108 135 179 200 225 255 289 . 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output(dBA) '' 8-17.5 16-33 Volts Volts • Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 4� ;r; AVDS86800 L-Series Dimensions 2.47 t.' 1.37 r 0 6.92 r_2.50 6.83 f- i; _ worn _— — I I ',i 8008 ,„. , , ,..,_, , , r ,, . i 4i ,,,, ,, j, 1 u.,... 80008 _ - -- Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box i t` 411r111116k• =- - vi.. VIII I Win .p IP.. .-7,31, of `T , 1 1.74. 1 ::::..:::.,,-.----------- --,,iii::::::::iY Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire, Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White t ,� SYSTEM ©2017 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specificatons subject to change wit^out not.V et systemsensor.corn �� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 for current product information,Including the latest version of the date sheet. AVDS86801•03/17 ti \`_ SYSTEM .. �� SENSOR® tylile ItItIsF I I I III I: 111111 Indoor Sele Ne- 111 R f R ®Lit ns, E f Strobes,es, and Horn Strobes for Wall Applications ft N 4 System Sensor L-Series audible visible notification1. - , products are rich with features guaranteed to cut k dm� .. installation times and maximize profits with lower ' current draw and modern aesthetics. Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry 1, • with lower current draws and modern aesthetics.With white and red '. • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain, FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can f' • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming ground faults. • • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, •. automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING !11! APPROVED % ig LISTED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 11/2-inch back box,4-inch t, octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 178-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series a products,when used with the Sync•CircuitT"Module accessory,shall be powered from a non coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist ' of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. t Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. 1 Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1'2 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. t 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. is 11 i UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 163 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB * DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 *Settings 9 and 10 are not available on the 2-wire horn strobes. 1 L-Series Dimensions = 1.91 3.46 1.25 �—3.46 _ = 1.25 - 1 r 1,!� rte'-r iitr r�\q 11111 r______ o1.3::Vig4: OrrOrrrOrrH 1000011�1000000000 r 000 OI A I000000000000 • I•A,I, 1111 • 000000000000.5.27 5.27epepepepepe'yeeeyey 88111181D0000r 81 ;), 1 ,1.1.1.1,1 , Compact Strobe/Horn Strobe Compact Horn 4.70 _ = 1.91 4.70 = �}— 1.25 _= 1.25 <7—' ifft) ifre---„,—:,..1!.,-.L.,.,,,,,,, j......" :i' ''-§'::': 5.67 .67 ,' 6/ \ I AM; ZA1A Strobe/Horn Strobe Horn L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns P2RL 2-Wire,Horn Strobe,Red HRL Horn,Red P2WL 2-Wire,Horn Strobe,White HWL Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red P2GWL 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red Wall Strobes SBBWL Wall Surface Mount Back Box,White SRL Strobe,Red SBBGRL Compact Wall Surface Mount Back Box,Red SWL Strobe,White SBBGWL Compact Wall Surface Mount Back Box,White SGRL Compact Strobe, Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover All-ALERT models have"ALERT"marking on cover i *� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2017 System Sensor. Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensoccom �� SENSORwww.systemsensor.com for current product information,including the latest version of this data sheet. AVDS86503•osin *Th_, SYSTEM SEN • urt Selectable-Outivat Low Frequency Sounder and L Frequency So . n + Strobes for Wall R 4 _ Applications SpectrAlerl°Advance audible visible notification products SPECTRAlert SkiiiirmainiSraraferE are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile • 520 Hz± 10%square wave tone and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry.With white and red plastic housings, • Plug-in design with minimal intrusion into the back box dual listed for wall and ceiling mounting,SpectrAlert Advance can • Tamper-resistant construction meet virtually any application requirement. • Field-selectable candela settings on wall units: 135, 150, 177,and 185 The wall-mount low frequency sounder,and low frequency sounder strobes were designed to address the NFPA 72 sleeping space • Rotary switch for low frequency sounder tone requirements that require a low frequency notification appliance that • Universal mounting plate for wall units operates within frequency range of 520 Hz±10%and is of a square • Mounting plate shorting spring checks wiring continuity before wave tone.Like the entire SpectrAlert Advance product line they include a variety of features that increase their application versatility device installation while simplifying installation.All devices feature plug-in designs • Electrically compatible with legacy SpectrAlert devices with minimal intrusion into the back box,making installations fast • Compatible with MDL3 sync module and foolproof while virtually eliminating costly and time-consuming • Listed for ceiling or wall mounting ground faults. To further simplify installation and protect devices from construction damage,SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring,so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, Agency Listings automatic selection of 12-or 24-volt operation,and a rotary switch for 520 Hz low frequency sounder tones. SIGNALING (131 MEA LISTED APPROVED approved S4011(sounder) 3047563 MEA452-05-E 7135-1653:0223 S5512(strobes) 7125-1653:0224 SpectrAlert Advance Specifications • Architect/Engineer Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.,A universal mounting plate shall be used for mounting products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit°°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150,177, and 185.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone and have a permanent marking on the housing that reads"low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire protective service.The low frequency sounder and the Sync•CircuitTM MDL3 Module accessory,if used,shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts(includes fire alarm panels with built in sync).When used with the Sync•Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts.If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used,then refer to the compatibility listing of the panel to determine maximum devices on a circuit.The low frequency sounder has an option to switch between temporal three pattern,non-temporal(continuous)pattern and coded supply within the frequency range of 520Hz±10%square wave tone.The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The sounder shall have an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three.Also,while operating the strobes,the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/2-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Frequency Range 520 Hz±10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm L x 119 mm W x 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142mmLx 119mmW x33mmD) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions(SBBR,SBBW) (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR,SBBW) (145 mm L x 120 mm W x 76 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. UL Current Draw Data UL Max.Low Frequency Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal 3 High 191 262 138 166 Continuous High 292 384 138 208 Coded High 292 388 153 205 UL Max.Current Draw(mA RMS),2-Wire Low Frequency Sounder Strobe,High Candela Range 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 3 277 292 325 344 Temporal 3 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Low Frequency Sounder Tones and Sound Output Data Low Frequency Sounder and Low Frequency Sounder Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR DC FWR DC FWR 1 Temporal 3 76 76 76 76 76 76 86 86 • 2 Continuous 80 80 80 80 80 80 90 90 3t Coded 80 80 80 80 80 80 90 90 t Sounder ratings provided are for continuous voltage as provided by the NAC • t 1 SpectrAlert Advance Dimensions 4.7 in. 2.5 in. ► 4.7 in. 1.1 1 3 in. A I III ,® 111 1111 A I®I 6.4 in. ===011 5.6 in. =0 . I I Imp 1111 LOW� I O SOWER II Wall-mount low frequency sounder strobes Wall-mount low frequency sounder SpectrAlert Advance Ordering Information Model Description Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe,High cd,Red P2WH-LF 2-Wire Low Frequency Sounder Strobe,High cd,White Low Frequency Sounders HR-LF Low Frequency Sounder,Red HW-LF Low Frequency Sounder,White Accessories SBBR Surface Mount Back Box,Wall,Red SBBW Surface Mount Back Box,Wall,White TR-HS Trim Ring,Wall,Red Notes: "High cd"refers to strobes that include 135,150,177,and 185 candela settings. SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2o15System senso'. SENSOR' Phone:800-SENSOR2•Fax 630-377-6495 Product speciticationssubject tochange without notice.Plsitsystemsensor.com SE/ for cu e t product mc tormatioo, lud ng the latest version of this data sheet. www.systemsensor.com 555516454.1/15 *•_, SYSTEM SENSOR° Outdoor Selectable. . , . 411111 Output Horns, s. £ . Strobes, and Horn Strobes for Wall Applications SPECTRANert SpectrAlerto Advance outdoor audible visible products &any A c are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes, and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate -' • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion.Knock-outs located on the back eliminate the need to drill s` ® holes for screw-in mounting.Plastic and metal weatherproof back MEA tvW boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch p 7300-1653:187(outdoor strobes) LISTED 7125-1653 188(hem strobes, knock outs at the back.A screw-in NPT plugwith an 0-ring gasket • 54011(chimes,horn strobes,horns) APPROVED approved chime strobes) 53593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653 189(horns,chimes) for a watertight seal is included with each back box. • SpectrAlert Advance Outdoor Horn, Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'°Module accessory,shall be powered from a non-coded notification • appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30,75,95,110, 115, 135,150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 i i UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 , UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 • Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Strobe Output(cd) Switch Sound Volts Volts Reverberant Anechoic Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 75 44 4 Temporal Non- High 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 9 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS012C1 SpectrAlert Advance Diagrams " I 11111 \ NI) 5.6" o 4 •! Wall-Mount Horn Strobes � � 7� Wall Plastic Weatherproof Back Box t' ' Ar.,0_ O r. • .11 r01111 r�yl Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK"t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK"t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK"t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High ed"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. 1 SYSTEM ©2012 System Senses. 3825 Ohio Avenue•St.Charles, IL 60174 Product specirica'ons subject to change w¢nout notice.vsit systemsensoccom SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 tor currc,tproduc:information,Including tholateac.version oftn.data snout. AVDS01201•3/12