Report STREET TREE
TIGARD CER TIFICA TION
I,
(or, Yo'SuiA- , owner/agent for 1uuck llonA6
(PLEASE PRINT) (PERMIT HOT DER)
do hereby cert that the following location meets
City of Tigard land use and development standards
for street tree installation and is consistent
with the approved site plan.
PERMIT NO.: /4 5rao i l- coo5061
SITE ADDRESS: iaol 4 5 w yvutraicy-
SUBDIVISION: a3SS L49161.5 LOT#: 8
SIGNATURE: DATE: 6/f 8il
(OWNER/AGENT)
RECEIVED &
VERIFIED BY: DA1E:
(CTTY OF TIGARD)
IE(Tree location verified per approved site plan.
I:\Building\Forms\StreetTreeCertificate 05/30/2012
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: (a ol, �Qt Jurisdiction: _
,304.
Site Address: voict S W bar cc
Subdivision/Lot#: � ro6 fc°SS LvnGF Lo-k- 0
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: ke Date: /464/9Owner/ ralContractor/Authorized Agent
Print Name: IA4S ( S(A2/4'
1 ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the fmal inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\Building\Forms\RES-HighEfficiencyLighting.doc 07/01/08
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, gMv,S , am the general contractor or the owner-builder
at the following address:
Site Address: vaso' SW ,p n if)teD Cr
City: 7
15 6teel
Permit#: AA ST Q011 —eeSo cf
Subdivision/Lot#: P royss L0-02/5 LOA- if
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code (ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: %� Date: 005
General %'e ntractor or Owner-Builder
I:\Building\Form\RES-MoistureSensitiveWood.doc 09/25/08
--ikoilissiolz4
-41,› '-:';'30 ',., .. El New
r'...-•.3'........-",::-...:y r„A,..-.•:.,
ED Existing
En] Removed
BACKFLOW ASSEMBLY TEST REPORT
E]Replacement
Property Riverside Homes, LLC
Owner
Mailing 17933 NW Evergreen Pl. Suite 370 Beaverton, OR 97006
Address
Phone:503-645-0986
Assembly
Address 12014 SW Redberry Ct Tigard, OR 97223
Ei R.P B.A. 133 D.C.V A.ED R.P D.A. ED 0 C.DA. ED P.V.B.A. ED S.V.B.A.E3 A.V.B. CI AIR GAP
SIZE: 1" MAKE: Febco MODEL: 850
Water Purveyor Tigard Serial# 57665
Assembly Location: Right side of the house by the fence door
REDUCED PRESSURE ASSEMBLY DOUBLE CHECK PVBA i SVBA. INITIAL TEST
#1 CHECK
AIR INLET CHECK PASSED El
INITIAL PRESS DROP cA) CHECK #1
TIGHT
TEST RELIEF VALVE r. 2.4 OPENED PRESS FAILED 0
OPENED AT (8) AT DROP
RESULTS MIN 2 PSID LEAKED 0 PSID DATE
BUFFER
PSDI P501 09/16 /18
A-B = CHECK #2
MIN 3 PSI --
RELIEF VALVE TIGHT Dii 2.9 DID NOT FAILED SYSTEM PSI
.....
PASS 0 FAIL 0 LEAKED U PSID OPEN
0 80
COMMENTS
REPAIRS
AND/OR
PARTS
REDUCED PRESSURE ASSEMBLY D C V A PVBA ; SVBA.
AFTER
TEST #1 CHECK CHECK #1 REPAIRS
AFTER PRESS DROP __ _(A TIGHT psi() OPENED PRESS
REPAIRS RELIEF 0 AT DROP DATE
OPENED (B)
MIN 2 PSID CHECK #2 PSDI PSDI
BUFFER TIGHT PSID
A-B =
0 PASSED 0
MIN 3 PSE
AV •
IN COMPLETING AND SUBMITTING THIS TEST REPORT,THE TESTER CERTIFIES THAT
THE ASSEMBLY HAS BEEN TESTED AND MAINTAINED IN ACCORDANCE WITH ALL APPLICABLE RULES
AND REGULATIONS OF THE WATER SYSTEM,AND STATE REGULATIONS
):
GAU .4 ,riGe(,TION DATE 12-19-17 DETECTOR METER READING
/5(
T TER SIGNATURE
TruScapes 503-707-0213 State Testers
Bonifacio Garcia Certification #6693
21600 NW Amberwood Drive Hillsboro, OR 97124
Gauge# 12171807
Ki SERVICE RESTORED
REPORT RECEIVED BY
0 FOUND OFF, LEFT OFF
14255 S.W.Galbreath Dr.,Sherwood,OR
Phone(503)625-9700-Fax(503)625-9730
Certificate of Insulation
Contractor: RIVERSIDE HOMES
Job Name: PROGRESS LANDING LOT 8 2885 Job Number: JB-49310
Customer ID: RIV101
Job Address: 12014 SW REDBERRY CT LOT 8 2885 Contractors Telephone: 503-645-0986
Proposal Number: BD-49310
City: TIGARD State: OR Permit Number:
Product Location
R21 15.251N X105 IN HD SF BATTS at exterior walls 9'
R-21 kraft faced batts at exterior wails 8'
R-21 unlaced batts at rim joists
FSK Facing at rim Joists
R-30 unlaced batts at garage ceiling
R-38 unlaced batts at fiat ceilings
Baffles at save vents
Foam No Expand Window&Door Potycel/Chink/caulk plate
1 blower d000r test
Loose fill Insulation(L77) R-38 in attic over living space
weatherstrip prep at attic accesses
R-30 unfaced batts at joist after deck 16-19-24"
weatherstrip prep at crawl accesses
THE FOLLOWING PRODUCTS HAVE BEEN INSTALLED AS SPECIFIED ABOVE
ELLULOSE R-Value Thickness Bags Footage
NAUF JETSTREAM ATTIC OF HOUSE 3$ �� .S
•WENS CORNING L77 ATTIC OF GARAGE
ERTAINTEED INSULSAFE
Authorized Agent: __AIN, •-• A. Date: "
'The higher the R-Value the greater the 14':*s Power.Loose fill insulations vary In thermal performance due to factors such as aging,
mean temperature,conviction,moisture absorption and insulation variation.
Page 1 of 1