Plans (421) a�3 s. � mUZ..(N 1-hit Com- Date: 9/12/2018 Project Name: Peter Hedgecock O FFAddress: IL'E. C Pr 12734 Southwest Morning Hill Court Tigard, Oregon 97223 To whom it may concern, 1. "Revise the module count on the strings. The permit pack is for 15 modules, but the strings shove- 18. " a. Adjusted to show appropriate panel count on each string. Updated the wire callout and the electrical calcs accordingly. Changes clouded in blue on PV5 and PV6. Please reach out to me directly if you have any questions. Scott Gurney Senior Design Manager scott.gurney@blueravensolar.com 385-498-4401 'Nee- The Future of Energy.�. Toda . Y BLUE RAVEN GENERAL NOTES AERIAL VIEW • Ne6-3 1. ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE(NEC),2015 y r x INTERNATIONAL RESIDENTIAL CODE(IRC).2014 NATIONAL BUILDING CODE(NBC),2015 ' ye 4' a �"Er+• a, r INTERNATIONAL BUILDING CODE(IBC),2015 INTERNATIONAL PLUMBING CODE(IPC),AND . ,� :(3- # # °�'k .�T *. x ALL STATE AND LOCAL BUILDING,ELECTRICAL.AND PLUMBING CODES. C 7 ° - _ 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. i°` ",s .. ]• •• -;ria `` ^-Ao * ',. #s " ./ -,I-: t y E �'� 1220 S.630E STE.430 y 01,4x.."j , + V s r _ a �` 4T - 104-7‘1.1*- AMERICAN FORK.UT 84003 '1~ . I a7" a V. a.►,'? * .16* 7.`'F a a l �(1i,. '. 800-377-4480 SITE NOTES 1 s 4 6 sly meq, ' • WWW.BLUERAVENSOLAR.COM r,• ..., .. 'fix. ,,`c-'4 �°'a `"5tt' .. -r,._ -., .1*! 44". . k: 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. "'' ' ''' $ - *t1`':,.:)` .4'`,. m » + + `�'` ° } a". r•., CONFIDENTIAL-THE INFORMATION 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY a " c " e ,, HEREIN CONTAINED SHALL NOT BE INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. a ! as +•. �,.: 1 .: - `" ,. aE'' • • USED FOR THE BENEFIT OF ' '. .tr F ?i :• x-1'1. :7 ,44,,I,,,]'',1-1411]�, Nw• _ �'' 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL.OR ? "`` :,�-, & ,-, s g „ ' v • a n " .ss::r - '"" ANYONE EXCERT ay t t..s. ,' �� -:9.10. s .o., e , ss:s BLUERAVENSOLAR E DISCODINNOR SHALL IT BUILDING ROOF VENTS. .' "� ` • t � r ` �." � � I`� ?� � •^��'�°�� �. 't °� � �:;t. ¢` �.�_ 3 :� BE DISCLOSED IN WHOLE OR IN 4. PROPER ACCESS AND WORKING e`{ -,rl .`..:: , "' , ,; i ; •: - t:.t { k,, i§ur '..._s•w '� ,•,' i` O CG SS CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL .� .� ,�,,, , , x ,¢'n .� � ,�,,.•=i:[�: ~��,: u.... �� . � 's` _:: ?, ,;.._ ., a ��c;,, . PART TO OTHERS OUTSIDE i 49 3,. . `..<- ` Y,.y'' 3`'. . nc,•R' :.. ,�r ' ^ d RECIPIENTS ORGANIZATION, EQUIPMENT WILL BE PROVIDED AS PER SECTION[NEC 110.26] 3 "� ° `� �,i,,. ,r „, ,. ., � = T�.: , � „Y THE GROUNDING ELECTRODE ND T ><: a. �a .a� •, ,Is `? ' I ,--,,..;2 EXCEPT IN CONNED TION WITH THE 5CONDUCTOR ORSHALL BE PROTECTED FROM PHYSICAL DAMAGE } ( ff # f � } a-, SALE AND USE OF THE RESPECTIVE I]5 �: .., a 1.1: .:..v.a ,_•:- w*'i""'+a . ,.,xa. - . _ : 1!3e:.r.,s BETWEEN THE GROUNDING ELECTRODE AND THE PANEL OR INVERTER)IF SMALLER THAN#6 .' u, f.,•-,;, ( >,. � �� � t)+� os� ���h it� � §.. "� a. _ ..,i: ... _. ,nny." s EQUIPMENT,WITHOUT THE AWG COPPER WIRE PER NEC 250-64B.THE GROUNDING ELECTRODE CONDUCTOR WILL BE ) Ijf s i:. 0. ..::,i:.... !bye "t r ,,ea,r m `.: WRITTEN PERMISSION OF CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER ei' s• ` ' BLUERAVENSOLAR LLC. [NEC 250.64C.] i 4 . ; t.: Iii r P llek * > 1 4 6. ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH ;+- .;.�a • . vi9 (n O s�€ a , 113 1.k.• O C9 THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF "]]k d'Rat'_ v_ � • `'4' 14% " ^Y W W W COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. ' �1 ! ' .,r -- • • • °"- i 0 1 �' O � a ak . a llN 7. RIGID CONDUIT(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROTECT WIRES. a m Q 0 0 r 8. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED aa, -n s, s .zF' R .c M CONDUCTOR(USE POLARIS BLOCK OR NEUTRAL BAR .'* �� WL. - . f ,- ''' -Pl.:"P:E'a ],r,,s : ,::.: ,a (°=s "•z :•'` .'k... ., , , ;,,: a ,- a. _ 0k ;. I- °° Z LL O ao 9. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS ? ".� Z DISALLOWED ABOVE LIVE PARTS.MEYERS HUBS RECOMMENDED . ' °: .4 liiii a , 10. UV RESISTANT CABLE TIES(NOT ZIP TIES)USED FOR PERMANENT WIRE MANAGEMENT OFF :i. s „ '•,•1114.441, -;:,•• -+ 0 O THE ROOF SURFACE IN ACCORDANCE WITH NEC 110.2.110.3(A-B).300.4 ::'::' " x _ w ; 11.SOLADECK JUNCTION BOXES MOUNTED FLUSH W/ROOF SURFACE TO BE USED FOR WIRE ,f '? r- ,. � k • + MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. • is .,, * '' ; C SOLAR CONTRACTOR ' - s # 1. MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730. • (. 2. IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING a - Y * }Ys & s $ ' SEP LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS. 41111.44 k • r r� 3. AS INDICATED BY DESIGN.OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED "- e: 7 " .:k, ' �- a t •..-- CITY PF T1GARD IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BYTHEAHJ. ASCE 7-10 WIND SPEED: 110 MPH OCCUPANCY - R3 SHEET INDEX U1 - iii 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND GROUND SNOW LOAD: 10 PSF , ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. CONSTRUCTION - V-B PV1 - COVER SHEET • • 0) ,,I //tI3 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND EXPOSURE CATEGORY: C Z - ZONING: RESIDENTIAL PV2 - PROPERTY PLAN SEALED WITH A SUITABLE SEALING COMPOUND. SEISMIC DESIGN CATEGORY: D O CV [,jj 6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. PV3 - SITE PLAN E- 2 ti N 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ PV4 - EQUIPMENT & ATTACHMENT DETAIL Q 6' (/) fx O cu c SUITABLE WIRING CLIPS. SCOPE OF WORK PV5 - ELECTRICAL SINGLE LINE DIAGRAM C o 8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR � � � VOC UNLESS NOT AVAILABLE DC SYSTEM SIZE: 4.35 kW DC A2PV6 - ELECTRICAL CALCULATIONS 0 a) o 9. ALL INVERTERS,MOTOR GENERATORS.PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS, ROOF TYPE: Comp Shingle & STRING DIAGRAM _Z 2 c) 0 c AC PHOTOVOLTAIC MODULES,DC COMBINERS.DC-TO-DC CONVERTERS.SOURCE CIRCUIT MODULES: (15) Sunmodule Plus SW 290M Black PV7 MBD CALCS. (IF NEEDED) LU . 2 C COMBINERS.AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWERin SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(B). INVERTER(S): Enphase IQ7-60-2-US,---- PV8 - LABELS & LOCATIONS _ d 0 4/2 N- ci3) U co 0 co 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. RACKING: Unirac Sunframe Microrail Mounting & Racking System PV9 - STRING & SE OPTIMIZER PV10 - PLACARD (IF NEEDED - NEC 690.56(B)) DRAWING BY EQUIPMENT LOCATIONS Marcelo Correa 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY[NEC 110.26]. ANCHORED ON MAX 48 INCH CENTERS USING UL LISTED RACKING 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING SYSTEM TO SPEC. City of Tigard TEMPERATURE AS SPECIFIED BY[NEC 690.31 (A)-(B)]AND[NEC TABLE 310.15(B)]. DATE 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT Appro +ed Plans September 12, 2018 TO THE UTILITY AC DISCONNECT.OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT. }Q (/4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING REVISION gy ®alb/ PROJECT NUMBERTO NEC APPLICABLE CODES. Q62�q 53043842 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE y\n CTU 6 I ,-' WHEN APPROPRIATE. 1 `�J l • SHEET NAME OFFICE COPY COVER SHEET PAGE NUMBER REVISION PV1 B LEGEND k ..f,' A ' INV INVERTER&DC DISCONNECTBLUE RAVEN SUB (E) SUBPANEL LC (N) LOAD CENTER 1220 S.630 E STE.430 AMERICAN FORK.UT 84003 AC AC DISCONNECT 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION 95'-7" M UTILITY METER!SERVICE PANEL HEREIN CONTAINED SHALL NOT BE } USED FOR THE BENEFIT OF JB JUNCTION BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE C COMBINER BOX RECIPIENTS ORGANIZATION. EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE PV PV REVENUE METER EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. ri /// FIRE SETBACK ©on EMT CONDUIT RUN W W O N (TO BE DETERMINED IN FIELD) ZH 'c IW FE �� ❑Q lii , PVWIRESTRING❑ Ell z U_ O O _ o ❑ MP1 i PROPERTY LINE U O M O M c 0 �''� ® := AZIMUTH:100° w U U m -)---- °' nm '�14rj PITCH30° 136' 5" SCALE: 1(16"= 1'-0"® 0' 4' 8' 10' 3z > (134-11 z ii TSRF:77% o MP4 .+�r- O fr iiiiti71-cv PITCH:15 MP311106 �00 111o ■ ® oU AZIMUTH:190° pp ff, _ PITCH:30° m k_ l' 13 _ TSRF:87% A Z. } MP2 N AZIMUTH:190° Q Y - ti N } PITCH:30° Et 2 o vwTSRF:93% 0 & W d- -a c C I 6 O AC DISCONNECT TO BE LOCATED 117' to d - I- 0 .- WITHIN 10' OF UTILITY METER DRAWING BY ROOF ATTACHMENTS SHALL BE SPACED Marcelo Correa NO GREATER THAN 24" ON CENTER IN ANY DIRECTION WHERE LOCATED DATE WITHIN 3' OF A ROOF EDGE, HIP, EAVE, September 12, 2018 OR RIDGE OSSC 3111.5.3 ITEM 3.35 PROJECT NUMBER DC SYSTEM SIZE: 4.35 kW DC 53043842 ROOF TYPE: Comp Shingle SHEET NAME (15) Sunmodule Plus SW 290M Black PROPERTY PLAN Enphase IQ7-60-2-US,----INVERTER PAGE NUMBER REVISION PV2 B LEGEND INV INVERTER&DC DISCONNECT SUB (E) SUBPANEL > //�\\ LC (N) LOAD CENTER 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 WW.BLUERAVENSOLAR.COM / WM AC C N M UTILITY METER/SERVICE PANEL CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF MSP O T Cial JB JUNCTION BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN \ vC, PART TO OTHERS OUTSIDE C COMBINER BOX RECIPIENTSANDUSEOF ORGANIZATION.THE EXCEPT IN CONNEC TION WITH THE SALE RESPECTIVE PV PV REVENUE METER EQUIPMENT,WITHOUT THE C U WRITTEN PERMISSION OF 40 BLUERAVENSOLAR /%/� FIRE SETBACK .j EMT CONDUIT RUN I-U W O d- � � (TO BE DETERMINED IN FIELD) Z O d /// +._I M P 1 Q U N-. ����I� ___ AZIMUTH:100° Z D C) Q ti 12" JBC ��� Lii � PITCH:30° PV WIRE STRING LU co } TSRF:77% I Zc) f- z I ; i PROPERTY LINE U 0 C') 0 W 0 ■ 0 �' m � SCALE: 118"= 1'-0" p q 12J MP40 O AZIMUTH:190° / ��■ Z PITCH:15° 'a t TSRF:95% �4 U U- //fY U I' ■ a) ////// / Z 0 L co 12" I- Cr N Q � � Uo � u.)JB Etc [G � JB, 0 m ., ( w U O o, m Z z co O CO WL CO AC DISCONNECT TO BE LOCATED MP3 H v () 0 p WITHIN 10' OF UTILITY METER AZIMUTH:190° u) °- _ 0 d' ROOF ATTACHMENTS SHALL BE SPACED PITCH:30° DRAWING BY NO GREATER THAN 24" ON CENTER IN TSRF:87% Marcelo Correa ANY DIRECTION WHERE LOCATED WITHIN 3' OF A ROOF EDGE, HIP, EAVE, DATE OR RIDGE OSSC 3111.5.3 ITEM 3.35 MP2 September 12, 2018 AZIMUTH:190° PITCH:30° PROJECT NUMBER TSRF:93% 53043842 DC SYSTEM SIZE: 4.35 kW DC } ROOF TYPE: Comp Shingle SHEET NAME (15) Sunmodule Plus SW 290M Black SITE PLAN Enphase IQ7-60-2-US,----INVERTER PAGE NUMBER REVISION PV3 B \PV ARRAY STRUCTURAL CRITERIA ' - ..., PV MODULE COUNT: 15 MODULES A PV MODULE(BEHIND TRIM RAIL) Unirac Sunframe Microrail TRIM RAIL \ • #OF ATTACHMENT POINTS: 45 BLUE RAVEN ARRAY AREA: Module Count x 17.51ft2 = 262.7ft2 ROOF AREA: 1997.6ft2 <->. OF ARRAY/ROOF: 13.1% 0 jr g 1' 11" g N Ng N N 1220 S.630E STE.430 ARRAY WEIGHT: Module Count x 50Ibs = 750.0Ibs ^ 48"MAX."MAX. AMERICAN FORK,UT 84003 800-377-4480 \ DISTRIBUTED LOAD: Array Weight=Array Area = 2.86 lbs/ft2 ARRAY DETAIL, FRONT VIEW WWW.BLUERAVENSOLAR.COM POINT LOAD: Array Weight_Attachments= 16.7Ibs/attachment Scale: 3/8" = I-0" CONFIDENTIAL-THE INFORMATION ROOF TYPE: Comp Shingle HEREIN CONTAINED SHALL NOT BE ROOF FRAMING TYPE: Rafter USED FOR THE BENEFIT OF RAFTER OR TOP CHORD SIZE: 2x8 Unirac Sunframe Microrail FRAME ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT RAFTER OR TOP CHORD SPACING: 24"O.C. BE DISCLOSED IN WHOLE OR IN ASCE 7-10 WIND SPEED: 110 MPH EXPOSURE CATEGORY: C CEILING JOIST OR BOTTOM CHORD SIZE: 2x6 PART TO OTHERS OUTSIDE SITE CRITERIA CEILING JOIST OR BOTTOM CHORD SPACING: 24"O.C. RECIPIENTS EC TIOZATI WITH GROUND SNOW LOAD: 10 PSF SEISMIC DESIGN CATEGORY: D EXCEPT USE O THE R SPECTI THE SFM Raised Seal Flashing SALE AND USE , THE RESPECTIVE EQUIPMENT,WITHOUT THE / WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. 40 #"-•1010 Unirac Sunframe Microrail UNIRAC TRIMRAIL L } o Ltno W ..1-1-1 71- OD' '4 Sunmodule Plus SW 290M Black • MODULE 30° Q - 1- U Q LL PV MODULE O ` �- WIDTH Z01 Q --I N-. 0 / ✓ \ QO 11-I (Y) Q } (E) ROOF / � � cp Z (� op0 I- o � I \ MEMBRANE `I. I— L ii 2 5�� 1 �—" ARRAY DETAIL, SIDE VIEW LU v U m O II .Qp UNIRAC SLIDERS AND —) U) 1— coCt TRIMRAIL ROOF ATTACHMENTS Scale: 3/8" = 1 -O" O ar O d CO To ki J o 2.5" MIN. EMBED. FLASHING Q IAC DISCONNECT TO BE LOCATED 1 5/16"STAINLESS STEEL LAG BOLT p WITH 2-1/2" MIN. EMBEDMENT WITHIN 10' OF UTILITY METER t AND FLAT WASHER ROOF ATTACHMENTS SHALL BE SPACED o C7 (E) BUILDING NO GREATER THAN 24" ON CENTER IN 0 STRUCTURE ANY DIRECTION WHERE LOCATED i WITHIN 3' OF A ROOF EDGE, HIP, EAVE, :m OR RIDGE OSSC 3111.5.3 ITEM 3.35 zE O Eco o N W N Unirac Sunframe Microrail H a) N Q a) 2 o 0 c (7) 00 Sunmodule Plus SW 290M Black z �o O co E— 0 Z • PV MODULE I - >- < II W a) co Lo Y 00 � _ � O. F o a = ° ;-'-ii 9 I (E) ROOFDRAWING BY 2.5" MEMBRANE= Marcelo Correa J = O m Y UNIRAC SLIDERS DATE � September 12, 2018 Ju) 2.5" MIN. EMBED.El FLASHING PROJECT NUMBER w 0 53043842 5/16"STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT SHEET NAME = AND FLAT WASHER EQUIP. DETAIL (E) BUILDING STRUCTURE PAGE NUMBER REVISION PV4.1 B 11" — 14' 8'-2" - 8'-2" 1'-7" BLUE N LBW LBW 1220 S.630E STE 430 STRUCTURAL SIDE VIEW AMERICAN FORK,UT 84003 1800-377-4480 Scale: 3/8" = 1'-0" WWW.BLUERAVENSOLAR COM RAFTER: 2x8 @ 24"OC CONFIDENTIAL-THE INFORMATION CEILING JOIST: 2x6 @ 24"OC HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT _.....1,... _r._ BE DISCLOSED IN WHOLE OR IN 14'-5" I 3' l PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, 30'-9'I EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE Q p WRITTEN PERMISSION OF - 1'-7" L 7'-8" 7'-8" - 1'-7" "�— BLUERAVENSOLAR LLC. - ,4000000. Z D cm Q ti U0 � 0 � � w CO RAFTER: 2x8 @ 24" OC o co CEILING JOIST: 2x6 @ 24" OC ct `---- LBW ( STRUCTURALSIDEVIEW LBW o 2 �`� Scale: 3/8" = 1 '-O" w cm 15'-8" z I= mo o c\i W 1'-3" 12' — 10'-4" — 1'-7" I— N Q Y rn : o -- cVJ DH.� oo) W U W W U co 0 DRAWING BY RAFTER: 2x8 @ 24" 00 Marcelo Correa CEILING JOIST: 2x6 @ 24" OC DATE September 12, 2018 PROJECT NUMBER 53043842 LBwSTRUCTURAL SIDE VIEW LBW 3SHEET NAME EQUIP. DETAIL 1 Scale: 3/8" = 1'-0" _ ^\,— PAGE NUMBER REVISION 22'-9" I PV4.2 B /11111 .401111116.4111111111.411111\/111\ 1'-5" 6' 2'-4" • BLUE RAVEN UT 12RE 430 AMERICAN FORFORK,UT 84003 800-377-4480 WW W.BLU ERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLARLLC. I-U 7r ~ U' ddZa) < Ix t ,,, WU 2 Z c p L 1 oN W ¢ �, N ,/ 2 U 2'-4" 2'-4" 2'-4" L a 0 2 W O— zu00 } W L M co - Lo (n d _ d STRUCTURAL SIDE VIEW DRAWING BY 4Marcelo Correa DATE September 12, 2018 RAFTER: 2x8 @ 24" OC PROSECT NUMBER 53043842 CEILING JOIST: 2x6 @ 24" OC SHEET NAME EQUIP. DETAIL PAGE NUMBER REVISION PV4.3 B \,/ _____/ .____./ . /\ /\ ./`,..._/\ / �'' (1) 10 AWG THWN-2,COPPER,BLACK(UNE 1) 15.0 A AC (1) 12-2 UF-B WIG,SOLID COPPER MAX 15.0 A AC /'' (1) 12-2 UF-B WIG,SOLID COPPER MAX 15.0 A AC (1) 12-2TC-ER,THWN-2,COPPER MAX 15.0 A A / 1C (1) 10 AWG THWN-2,COPPER,RED(UNE 2) 240 V AC 3 240 V AC 1 .,__2) OR 12-2 TC-ER,THWN-2,COPPER,90C,COPPER 240 VAC (1) 6 AWG BARE,COPPER(EGO 240 VAC \1 5 )(i) 10 AWGTHWN-2,COPPER,WHITE(NEUTRAL) (1) 10 AWGTHWN-2,COPPER,GREEN(GROUND) (1) 3/4 INCH EMT CONDUIT (1) 3/4 INCH EMT CONDUIT ) BLUE RAVEN• ! \ 1 1220 S.630E STE.430 AMERICAN FORK,UT 84003 800-377-4480 W W W.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE ALL CONDUIT TO BE RAN AT LEAST 7/8"ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT. USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE /N RECIPIENTS ORGANIZATION. B EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF (E)200A MAIN SERVICE PANEL (15)Sunmodule Plus SW 290M Black BLUERAVENSOLAR LLC. (E)200A/2P MAIN BREAKER ENPHASE IQ COMBINER UL 1703 COMPLIANT ® PV AC DISCONNECT X-IO-AM1-240-2 (15)Enphase 107-60-2-US MICRO INVERTERS L >- O L Cl) Q (E)200A/2P NON-FUSED (SOLAR LOADS ONLY) JUNCTION BOX(S) UL 1741 COMPLIANT w Ill O d c0 I LOCKABLE,VISIBLE OPEN OPTIONAL IF 5 MODULES MAX FOR ALL SUB-BRANCH 0 Z - 0 d- 30A,240V,2-POLE Q-CABLE(TC-ER) CIRCUIT(S)TO COMPLY WITH VRISE CALCS Q K 1b 0 0 r., USED FOR ENTIRE (E) — Z 0 1- Q HOMERUN Q Ur 1 W Cr --�Th� —N JUNCTION BOX - z L O ❑ ❑ III _ I— O C»05:� (A co — _ 1 CIRCUIT ❑ ❑ ❑ ( �2P (N)20A/2P ( ) �� 0 U o LtU u r u u OF 15 MODULES �J J m L2 L2 LZ L2 u) G N I- . ____ _____ 45r_ _ G _ _ i I— G — I _a_ 11 \ 120/240 VAC — V V U Ct 60HZ TO UTILITY GRID 160 2� 0 PV BREAKER TO BE LOCATED OPPOSITE END OF BUSSING FROM MAIN BREAKER (E) GROUNDING LECTRODE _ 0 N L1J N . ., Q Y N o C n F {{ O W U 1 INTERCONNECTION NOTES •,fir > z v (n O C/) 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF — _ >- BUSBARS AND PANELBOARDS. (a)THE SUM OF 125 PERCENT OF THE INVERTER(S)OUTPUTiiiLU o) M ca in CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE x F (— N N a) 0 M BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b)WHERE TWO SOURCES, �' •E i'-. 0 d- ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A I k: ... . DRAWING BY BUSBAR THAT CONTAINS LOADS,THE SUM OF 125 PERCENT OF THE INVERTER(S)OUTPUT I CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE : st Is.w Marcelo Correa • BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR[NEC 4. s 705.12(D)(3)[. 1 RDATE til it 1 September 12, 2018 3. GROUND FAULT PROTECTION IN ACCORDANCE WITH[NEC 215.9]&[NEC 230.95] xs p 4. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. Ili PROJECT NUMBER N, .,,y.:..,.. DISCONNECT NOTES >#..�5°S.:Iiiiiititnimi.klf:nmemiziramil,: i. _Nti..„..2,104v..,„fr 53043842 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS _... #€ OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE z "`{-:- ag > . _ 3E�� �,t�n T ,�� SHEET NAME TERMINALS MARKED"LINE SIDE”(TYPICALLY THE UPPER TERMINALS) : , $ S c 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE ' ELEC. 3 LINE DIAL. LOCKABLE,AND BE A VISIBLE-BREAK SWITCH "{�, ' PAGE NUMBER REVISION 3. DC CURRENT CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TOa EITHER A FUSEABLE SOURCE CIRCUIT ""'" ' `" PV5 B (v16 ULE5PEOF|[ATDN5 Sunmodule Plus SW 290M Black DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS ` RATED POWER(STC) 290 W TEMPERATURE DATA SOURCE ASHRAE 2%AVG.HIGH TEMP MICROINVERTER TO JIAX.SHORT CIRCUIT CUR0RENT(ISC) = 15.0AAC MODULE VOC 40 V DC STATE Oregon JUNCTION BOX MAX.CURRENT(ISC X1.25)= 18.8 A AC 'MODULE VK4P 31 V DC CITY Tigard CONDUCTOR(TC-ER,COPPER(90°C))= 12 AWG BLUE RAVEN \ MODULE IMP 9.3 A DC WEATHER STATION PORTLAND INTERNATIONAL AP CONDUCTOR RATING= 30 A MODULE ISC 10 A DC ASHRAE EXTREME LOW TEMP(°C) -6 AMB.TEMP.AMP.CORRECTION= 0.96 VOC CORRECTION (%/°C) 'U.3 ^[ AVG.ASHRAEIY6H|GHTEK4P(`C) 32 ADJUSTED = 28.8 > 18.8 1220 S.630 E STE.430 AMP. / VMP CORRECTION (%/°C) -0.4 °C JUNCTION BOX T0 AAXSHORT CIRCUIT CURRRENT(|SQ= 15.0AAC AMERICAN FORK,UT 84003 800-377-4480 SERIES FUSE RATING 25ADC SYSTEM ELECTRICAL SPECIFICATIONS OR1 C|R2 C|R3 C|R4 C|R5 C|R6 COMBINER BOX MAX.CURRENT(|SCXl25) = 18.8AAC > ADJ. MODULE VOC @ ASHRAE LOW TEMP 43.7 V DC NUMBER OF MODULES PER MPPT 15 INDUCTOR(THWN-2,COPPER(90°C))= 12 AWG CONFIDENTIAL-THE INFORMATION ADJ. MODULE VMP @ ASHRAE 2%AVG. HIGH TEMP 26.1 V DC DC POWER RATING PER CIRCUIT(STC) 4350 CONDUCTOR RATING= 25 A HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF TOTAL MODULE N UMBER 15 MODULES CONDUIT FILL DERATE= 1 ANYONE EXCEPT \ / MICROINVERTER SPECIFICATIONS Enphase IQ7-60-2-US STC RATING OF ARRAY 4350W DC AMB.TEMP.AMP.CORRECTION = 0.96 BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN POWER POINT TRACKING(K4PPT)MIN/MAX 22 - 48 VD[ A[CURRENT @ MAX POWER POINT(|k1P) 15.0 ADJUSTED AMP.= 24 > 18.8 PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, MAXIMUM INPUT VOLTAGE 48 V DC CURRENT(|K4PX18.75 EG[ ISC= 1�OAAC XCEPT IN CONNEC TION WITH THE SAMAX.� 1.25) � ' MAX|K4UK4DCSHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 CHANNEL 18.8AAC -- - - -RESPECTIVE MAX.� EQUIPMENT,WITHOUT THE MAXIMUM USABLE DC INPUT POWER 350 W MAX.COMB.ARRAY AC CURRENT(IMP) 15.0 INDUCTOR(THyVNZ,COPPER(90°C)) = 10 AWG WRITTEN PERMISSION«r amsexvswooLxnuc. \ N1AX|K8U[NOUTPUT CURRENT 1 A AC MAX.ARRAY ACPOVYER 3G00VVAC EGCCONDUCTOR RAllNG= 20 A > � � >. [�� � ACOVERCURRENTPROTECOON 20 A CONDUIT FILL DERATE= 1 [� Cr) uJ �U `_ o- K8AX|W1UK4OUTPUT P0VVER 250VV AC VOLTAGE RISE CALCULATIONS 0ST(FT)/R|3E(Y) VEND(V) %VRISE |C7-5 APW8.TEK4P.A�NP.CORRECTION= 0.96 Z0 .;j- \ [� / CECVV[|GHTEDEFFICIENCY 97Y6 VR|SESEC. 1(K8|CROTOJ8OX) 18 0.36 240.36 0.15% ADJUSTED Ak8P.= 19.2 > 18.8 ) Z D --.1 N- V R I S E SEC. 2(JBOX TO COMBINER BOX) ~VR|SESE[. 2(JBOXTO[QK8B}NERB0X) 50 3.03 243.03 1.26% COMBINER BOX TO INVERTER RATED AMPS= 15.0 A AC < 0 LU co ACPHOTOVOLAT|CK4ODULEK�ARK|NG(NEC 69O5�) VR|SE�EC 3(CO��8|mERBOXTOPO|) 1U O3O Z4O38 O1�� yMA|NPVO�PD W1�X CURRENT(RAJEDAy0P�XlI5) = I875AAC �� uo �� cz \ ' ' � � � � ' ' ou c� / | ' cn ow ' NOMINAL OPERATING 240VAC | TUTALVR|SE 1.57% INDUCTOR(THVVN-lCOPPER(�7(])= 10AVVG [) " NOMINAL OPERATING ACFREQUENCY 47 68HZAC CONDUCTOR RATING= 35 ii `' `~ cu \ K4AX|��U��ACPOVVER 240 VA AC PHOTOVOLTAIC AC0SCONNECTOUTPUT LABEL(NEC 69O.54) CONDUIT FILL DERATE= 1 [) > O� MAXIMUM AC CURRENT 15.0 A AC AC OUTPUT CURRENT 15.0 A AC AMB.TEMP.AMP.CORRECTION= 0.96 D_ MAXIMUM OCPD RATING PER CIRCUIT 20 A AC NOMINAL AC VOLTAGE 240 V AC ADJUSTED AMP.= 33.6 , 18.8 \ / / /p\ > / ^' \ �� = 0O � � GROUNDING NOTES 10.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO[NEC 6. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 • • 1. AGROUNDING ELECTRODE SYSTEM|mACCORDANCE WITH[NEC nnn-47 *mo 690.45] AND���m|w|mu�or�1n�womm�mwoT�xpossoToo�m�o��o�vvo INSULATED,em^ow�T�wouvRATED FOR 600V Z^ RATED, RESISTANT, [NEC 250-50]THROUGH[NEC 250-60]SHALL BE PROVIDED.PER NEC, SHALL BE USED WHEN EXPOSED TO DAMAGE). 7.4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER [ c 0 UJ GROUNDING ELECTRODE SYSTEM nFEXISTING amuo|wnMAY BEUSED AND /1GROUNDING AND BONDING CONDUCTORS, |FINSULATED,SHAuoECOLOR VOLTAGE ToGROUND MARKED ORANGE o*mewT|p/eoovOTHER sFFEcnveMEANS. � �m. Ni BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE CODED GREEN(OR MARKED GREEN IF#4 AWG OR LARGER) 8.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION cf) OR INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL 12. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF 9.VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 10. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS 0 0 CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 13.SYSTEM GEC SIZED ACCORDING TO[NEC 690.47],[NEC TABLE 250.66],DC FOLLOWS:DC POSITIVE-RED(OR MARKED RED),DC NEGATIVEGREY(OR MARKED GREY) u- 73 � c 0 2. GROUNDING ELECTRODE CONDUCTORS SHALL aswoLESS THAN#8 AWG AND SYSTEM GEC SIZED ACCORDING TO[NEC 250.166] MINIMUM#oAvm;WHEN 11. POSITIVE GROUNDED SYSTEMS ooCONDUCTORS COLOR CODED: �� m co 0^ NO GREATER THAN#6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING /wouLATsowsAvvoWHEN EXPOSED TooAMAGEooposmvE'GREY(OR MARKED nnEY) oowEoATwE-oLAom(oR MARKED BLACK) LU h7 ELECTRODE ToPROVIDE FOR ACOMPLETE aYnTEm 14.EXPOSED NON-CURRENT CARRYING METAL PARTS VrMODULE FRAMES, 1zAoCONDUCTORS"^AWaCOLOR CODED onMARKED: F� �� � {} o 3. PvSYSTEM aHAueeGROUNDED/wACCORDANCE To[NEC osnu1].[NEC TABLE EQUIPMENTS,AND CONDUCTOR ENCLOSURES nyxueeGROUNDED|w PHASE xonL1BLACK, PHASE eoRo'RED,PHASE uoRm'BLUE,NEUTRAL- V9 c[ �� i= 0 4 250.122]. AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO[NEC ACCORDANCE WITH 250.134 OR 250.136(A)REGARDLESS OF VOLTAGE. WHITE/GRAY DRAWING BY 69046] *USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY Marcelo Correa 4. MODULE SOURCE CIRCUITS SHALL oEGROUNDED/wACCORDANCE TO[NEC WIRING mCONDUIT NOTES BE USED INSIDE 690.42]. 1.ALL CONDUIT SIZES AND TYPES,SHALL BE LISTED FOR ITS PURPOSE AND **USE-2 IS AVAILABLE AS UV WHITE 5. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT APPROVED FOR THE SITE APPLICATIONS 13.IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL DATE THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR 2.ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR BE EITHER EMT, FMC,OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31,NEC September 12, 2018 TO ANOTHER MODULE. CABLE LISTED AND IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT;ROUTED TO 250.118(10).DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 6. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS SOURCE CIRCUIT COMBINER BOXES AS REQUIRED 14.CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE PROJECT NUMBER IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 3.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC COMPLYING WITH NEC 230.6(4)AND SECURED NO GREATER THAN 6'APART PER NEC 53043842 7. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH 690.8] FOR MULTIPLE CONDUCTORS 330.30(B). AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION 4.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED SHEET NAME GROUNDING LUGS. AT LEAST 7/8"ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO[NEC TABLE E| EC. CALCS. 8. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND o1n.1s(o)(z)(a).NEC TABLE a1o.1o(e)(u)(a).0NEC o1o.1s(a)(n)<c8. GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 5.EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90°C RATED,WET AND UV PAGE NUMBER REVISION 9. COPPER,GROUNDING AND BONDING CONDUCTORS SHALL eesouoon RESISTANT,�wou�uaTson�Tso�onuvn�Teo�P|���vvn�Pn��ua� 600V, PV6 B _ LABEL 1 a .;gs .. .. LABEL 7 -iFOR PV DISCONNECTING MEANS WHERE ALL WARNING: PHOTOVOLTAIC AT DIRECT-CURRENT EXPOSED RACEWAYS.CABLE TRAYS,COVERS AND ENCLOSURES OF JUNCTION BOXES,AND OTHER TERMINALS OF THE DISCONNECTING MEANS MAY BE ° WIRING METHODS;SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES,WALLS,PARTITIONS, ELECTRIC SHOCK HAZARD ENERGIZED IN THE OPEN POSITION. POWER O[ I CE CEILINGS,OR FLOORS. RAVENBLUE TERMINALS ON THE LINE AND [NEC 690.13(B),NEC 705.22] «; ./ J [NEC 690.31(G)(3&4)] LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITIONLABEL 8 LABEL 11 SOLAR PV SYSTEM EQUIPPED FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY A PERMANENT DIRECTORY TO BE LOCATED AT 1220 S.630 E STE.430 WITH RAPID SHUTDOWN AND CONDUCTORS LEAVING THE ARRAY: AMERICAN FORK,UT 84003 SIGN TO BE LOCATED ON OR NO MORE THAN 3 MAIN DISTRIBUTION UTILITY DISCONNECT(S) MAIN SERVICE EQUIPMENT LOCATION IF ALL LABEL 2 TURN RAPID SHUTDOWN POWER TO THIS BUILDING IS ALSO SUPPLIED ELECTRICAL POWER SOURCE DISCONNECTING DIRECT CURRENT AT EACH DC DISCONNECTING MEANS,INCLUDING THE SWITCH TO THE FT AWAY FROM SERVICE DISCONNECTING FROM A ROOF MOUNTED SOLAR ARRAY WITH MEANS (SOLAR ARRAY RAPID SHUTDOWN 800-377-4480 'OFF POSiTIONTO sa _ MEANS TO WHICH THE PV SYSTEMS ARE A RAPID SHUTDOWN DISCONNECTING MEANS SWITCH)ARE GROUPED AND IN LINE OF SITE OF WWW.BLUERAVENSOLAR.COM f �•`` DC DISCONNECT AT THE INVERTER. SHUTDOWN PV SYSTEM I---“'�'��� GROUPED AND WITHIN LINE OF SITE p-.0TOVOLTAIv POWER SOURCE - CONNECTED AND SHALL INDICATE THEMAIN SERVICE DISCONNECTING MEANS. [NEC 690.53,NEC 690.13(B)] AND REDUCE AND 10 FT LABELED THIS LOCATION. MINLOCATION OF ALL IDENTIFIED RAPID SHUTDOWN CONFIDENTIAL-THE INFORMATION - SHOCI(HAZARO SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)&NEC 705.10]. HEREIN CONTAINED SHALL NOT BE MAXIMUM VOLTAGE VDC __INTHEARRAY USED FOR THE BENEFIT OF MAX CIRCUIT CURRENT AMPS I [NEC 690.56(C)(1)(A)] ANYONE EXCEPT BLUE RAVEN .., LABEL 12 SOLAR NOR SHALL IT BE LABEL 9 .ai PERMANENT DIRECTORY TO BE LOCATED AT DISCLOSED IN WHOLE OR IN PART SOLAR PV SYSTEM EQUIPPED FOR PV SYSTEMS THAT ONLY SHUT DOWN POWER TO THIS BUILDING IS ALSO SOLAR ARRAY RAPID SHUTDOWN SWITCH TO OTHERS OUTSIDE RECIPIENTS n SYSTEM LABEL 3 WITH RAPID SHUTDOWN CONDUCTORS LEAVING THE ARRAY: SUPPLIED FROM MAIN DISTRIBUTION DENOTING THE LOCATION OF THE SERVICE ORGANIZATION,EXCEPT IN PHOTOVOLTAIC//�� SYSTEM AT POINT OF INTERCONNECTION,MARKED AT ACSIGN TO BE LOCATED ON OR NO MORE THAN 3 EQUIPMENT LOCATION IF SOLAR ARRAY RAPID CONNECTION WITH THE SALE AND TURN RAPID SWITCH FT AWAY FROM SERVICE DISCONNECTING UTILITY DISCONNECT LOCATED INSIDE SHUT DOWN DISCONNECT SWITCH IS NOT USE OF THE RESPECTIVE AA DISCONNECT/+ DISCONNECTING MEANS. To-wow' IT I POSs AC DISCONNECT A [NEC 690.54,NEC 690.13(B)] TO SHUT DOR CONDUCTORS MEANS TO WHICH THE PV SYSTEMS ARE BUILDING IN GROUPED AND WITHIN LINE OF SITE OF MAIN EQUIPMENT,WITHOUT THE OUTSIDETF ARRAY CONNECTED AND SHALL INDICATE THE SERVICE DISCONNECTING MEANS. WRITTEN PERMISSION OF BLUE CONDUCTORSWITHINLOCATION OF ALL IDENTIFIED RAPID SHUTDOWN [NEC 705.10] RAVEN SOLAR LLC. RATED AC OUTPUT CURRENT A THE ARRAY REMAW ENERGIZED INSUNLIG,HT , SWITCHES IF NOT AT THE SAME LOCATION. NOMINAL OPERATING AC VOLTAGE [NEC 690.56(C)(1)(B)] LABEL 13 C } p L CD PERMANENT DIRECTORY TO BE LOCATED AT MAIN W LU 0 O . Powell TO THIS BUILDING IS ALSO SUPPLIED SERVICE EQUIPMENT DENOTING THE LOCATION 0 I H LABEL 4 ! LABEL 10 OF THE PV RAPID SHUTDOWN SYSTEM Q 00 0 Q N- ^� SIGN LOCATED AT RAPID SHUT DOWN FROM ROOF MOUNTED SOLAR ARRAY.SOLAR D AT POINT OF INTERCONNECTION FOR EQUIPMENT DISCONNECTING MEANS IF SOLAR ARRAY RAPID z < _..I I- CONTAINING OVERCURRENT DEVICES IN CIRCUTSDISCONNECT SWITCH[NEC 690.56(C)(3)]. ARRAY RAPID SHUTDOWN DISCONNECT IS SHUT DOWN DISCONNECT SWITCH IS NOT < 0 W SUPPLYING POWER TO A BUSBAR OR CONDUCTOR s LOCATED OUTSIDE NEXT TO UTILITY METER. GROUPED AND WITHIN LINE OF SITE OF MAIN 2 H LC') I— LL O DUAL POWER SUPPLY SUPPLIED FORM MULTIPLE SOURCES,EACH SERVICE :'' A ROW-SiME i SERVICE DISCONNECTING MEANS.[NEC 705.10, H Z [n CD SOURCES: UTILITY GRID AND EQUIPMENT AND ALL ELECTRIC POWER PRODUCTION NEC 690.56(C)(1)] U 0 SOURCE LOCATIONS. PV SOLAR ELECTRIC SYSTEM [NEC 705.12(6)(3)] LI Y V m LABELING DIAGRAM FOR MICRO INV.: 0 LABEL 5 MAIN SERVICE PANEL d y G PLACED ADJACENT TO THE BACK-FED BREAKER EXISTING SUB PANEL PV COMBINER ..,. a .,....... FROM THE INVERTER IF TIE IN CONSISTS OF LOAD O0 (IF WHERE POINT OF SUBPANEL- INVERTER OUTPUT CONNECTION SIDE CONNECTION TO BUSBAR. INTERCONNECTION IF USED TO COMBINE AC JUNCTION BOX [NEC 705.12(6)(2)(3)(b)] O IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS OR AC COMBINER BOX DO NOT RELOCATE THIS OVERCU,RRENT a o OOR( 9] O O O O O o DEVICE _� 0 aoo 11 13 OR O 6 LABEL 6 OR PLACARD 12 OR 11 I fey (ONLY IF 3 OR MORE SUPPLY SOURCES TO PLACARD G z C A BUSBAR) co SIGN LOCATED AT LOAD CENTER IF IT / O � 0 O CV U.I THIS EQUIPMENT FED BY MULTIPLE CONTAINS 3 OR MORE POWER SOURCES. (ONLY IF PV (ONLY IF PV a-- o I— 2 LINTERCONNECTION NTERCONNECTION Q ... .. N SOURCES.TOTAL RATING OF ALL [NEC 705.12(B)(2)(3)(C)] CONSISTS OF LOAD U CONSISTS OF LOAD N OVERCURRENT DEVICES,EXCLUDING SIDE BREAKER) SIDE BREAKER) o OU ?� o 2 MAIN SUPPLY OVERCURRENT O FD” W DEVICE.SHALL NOT EXCEED O -a E o H 0 LABELING DIAGRAM FOR STRING INV./DC OPTIMIZER INV.: O O Q C/) AMPACITY OF BUSBAR. z = to } MAIN SERVICE PANEL — OO EXISTING SUB PANEL(IF WHERE PV COMBINERSPANEL- INVERTER(5) N 00 f6 LABEL 11 1 3 INTERCONNECTIONIFNT FUUSED TO COMBINE a. co H a e a SIGN LOCATED AT AC COMBINER BOX FOR (� IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS ALL MICRO-INVERTER/AC MODULE DRAWING BY INSTALLS(IF APPLICABLE). o o �$ ORO O O Q ® 1� Marcelo Correa RAPID SHUTDOWN TEST NOT REQUIRED 0 OR CD 0 3 DATE OR PLACARD 12 OR OA?C II JUNCTION BOX September 12, 2018 LABELING NOTES: P CARD DC OR COMBINER BOX 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO O O 11 PROJECT NUMBER DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND (ONLY IF PV (ONLY IF PV �ioO O 53043842 MAKE APPROPRIATE ADJUSTMENTS. INTERCONNECTION NTERCONNECTION o--- 1 D 2 19010.145,LABELING ANSI REQZ53UIREMENTS ENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE,OSHA STANDARD CONSISTS E BREAKER)LOAD JOS SI TS OF LOAD 0.,.......o0 O7 SHEET NAME 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. LABELS 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED[NEC INTEGRATED DC DISCONNECT 11] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8",WHITE ON RED BACKGROUND;REFLECTIVE, *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PAGE NUMBER REVISION AND PERMANENTLY AFFIXED[IFC 605.11.1.1] PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. PV8 B , • BLUE RAVEN AAA 0 \ POWER TO THIS BUILDING IS ALSO SUPPLIED FROMAMERICAN FORK.UT8003 ROOF MOUNTED SOLAR ARRAYS WITH SAFETY 800-377-4480 DISCONNECTS AS SHOWN : WWW.BLUERAVENSOAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE RAPID SHUTDOWN AC USED FOR THE BENEFIT OF w ANYONE EXCEPT DISCONNECT SWITCH BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CCM N PART TO OTHERS OUTSIDE _ IT11411r RECIPIENTS ORGANIZATIONEXCEPTINCONNECTIONWITHTHESALE ANDUSE OF THERESPECTIVE 0,_ EQUIPMENT,WITHOUT THE II WRITTEN PERMISSION OF Z BLUERAVENSOLARLLC. 0 ill 1-11 III O Cl- LL 0 cil d- o ood• � 0 Z• o a) Q CC W C~ MAIN DISTRIBUTION • 1- 00 Lip Z UTILITY DISCONNECT ■ II 3 0 cr) 0 g2 lii„ w UU m0 1 O0 0 OEMCC �� d PV ARRAY t 12734 SOUTHWEST MORNING HILL COURT, TIGARD, OREGON 97223 0 0) z E N L • i DIRECTORY O N PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION < a rn OF THE SERVICE DISCONNECTING MEANS AND THE cc ° o 2 PHOTOVOLTAIC SYSTEM DISCONNECTING. 0 & .-, o U_ -0 o H WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH Z = w 0 C OTHER, A DIRECTORY I SHALL BE INSTALLED AT EACH DC PV , 2 CO ” SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING °' N 0 c? MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS DRAWING BY SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM Marcelo Correa DISCONNECTING MEANS IN THE BUILDING. ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC DATE September 12, 2018 ENGRAVE IN CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED USING AN APPROVED METHOD. IF EXPOSED PROJECT NUMBER TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND 53043842 SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC. SHEET NAME [NEC 690.56(B)&(C)] [NEC 705.10]. PLACARD PAGE NUMBER REVISION PV10 B BLUE RAVEN • Data Srmct Enphi:e Microt -rters Region_AMERiCAS 1220 S.630 E STE.430 Enphase IQ 7 and IQ 7+ Microinverters AMERICAN FORK,UT 84003 800-377-4480 INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US WWW.BLUERAVENSOLAR.COM Commonly used module pairings' 235 W-350W+ 235 W-440 W÷ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules CONFIDENTIAL-THE INFORMATION Maximum input DC voltage 48 V 60 V HEREIN CONTAINED SHALL NOT BE 'e it_gh-powereci smart grid-ready USED FOR THE BENEFIT OF Enphase . 1 ase IQ 7 MCP:17* and Enphase IQ ii+Micri " Peak power tracking voltage Operating range 27 V-37 V 16 V-48 V 27 V-45 V 16 V 60- V ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT IQ 7 and IQ 7+ dramatically simplify the installation process whi eMin/Max start voltage urrent(module lsc) 22 V i 48 V Max DC short circuit c 15 A 22 V/60 V 15 A BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION. achieving the highest system efficiency. Overvoltage class DC port II II EXCEPT IN CONNEC TION WITH THE . tvlc iro'JHitiverters Part of the Enphase IQ System,the IQ 7 and DC port backfeed current CA 0 A SALE AND USE OF THE RESPECTIVE PV array configuration 1 x 1 ungrounded array,No additional DC side protection required, EQUIPMENT WITHOUT THE AC side protection requires max 20A per branch circuit WRITTEN PERMISSION OF Microinverters integrate with the En phase BLUERAVENSOLAR LLC. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter IQ Envoy",Enphase IQ Battery" and the Enphase Peak output power 250 VA- 295 VA Enlighten.' monitoring and analysis software. Maximum continuous output power 240 VA 290 VA Nominal(LL)voltage/range' 240 V/ 208 VI 240 V/ 208 V/ LU ;-1-1 .1- 0 211-264 V 133-229 V 211-264 V 183-229 V 0 -._ ‘zr:r 1_,_ — .71- 10 Series Microinverters extend the reliability Maximum continuous output current 1 0 A(240 V) 1 15 A(208 V) 121 A(240 V) 1.39 A(208 V) < Ct 00 0 0 r....: standards set forth by previous generations and Nominal frequency 60 Hz 60 Hz Z D CY) < Cr) l'- < undergo over a million hours of power-on testing, Extended frequency range 47-68 Hz 47-68 Hz :E HH UJ C, AC short circuit fault current over 3 cycles 5.8 Arms 5 8 Arms I__ 2: > CD , . . enabling Enphase to provide an industry-ieading Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) ()1— 0 C° 0 < C° Overvoltage class AC port Ill Ill 0 12 warranty of up to 25 years_ Ill— 0 AC port bac kfeed current 0 A 0 A —) (J) LU Power factor setting 1.0 1.0 0 D Power factor(adjustable) 0.7 leading 07 lagging 0.7 leading.. 0.7 lagging CL CO EFFICIENCY @240 V @208 V @240 V @208 V .-- --- . - Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 970% 97.0% 97 0% 97 0% MECHANICAL DATA Easy to Install Ambient temperature range -40K to+65°C Olt and simple Relative humidity range 4%to 100%(condensing) .„„. . 17777!' 711; ririi.... . -i- • Faster instal. .i..n with improved,Ii... -:two-wire cabling Connector type(107-60-2-US&1127PLUS-72-2-US) MC4(or Ampheno1 H4 UTX with additional Q-DCC-5 adapter) rri'orvs .la Connector type(1Q7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 interrnateable) ' Built-in rapid -, . *v compliant(NEC At 4&2017) Adaptors for modules with MC4 or UTX connectors. -PV2 to MC4 order ECA-S20-S22 -PV2 to UTXi order ECA-S20-S25 ilIl i - Prodictive and Reliable Dimensions(WxHxD) 212 mm x 175 mm x 30.2 rnm(without bracket) .- -- _ Weight 1.08 kg(238 lbs) • Optimized for hicfri powered 60-oell and 7'2-42ell*modules Cooling Natural convection-No fans • More than a million hours of testing Approved for wet locations Yes ' • Class 11 double-insulated enclosure Pollution degree PD3 ' ., • UL 6.sted Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category!UV exposure rating NEMA Type 6 7 outdoor FEATURES Smart Grid Ready Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options . • Complies, .'* advanced grid support,voltage and Both options require installation of an Enphase IQ Envoy - op frewency ride-through rewirerrents Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break ,. '. • Remotely updates to respond to changing .. . disconnect required by NEC 690 . • . gild requirements Compliance CA Rule 21(UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, Configurable for varying grid profiles CAN/CSA-C22.2 NO.107.1-01 • Meets CA Rule 21 CU L 1741-SA) This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NIEC-2017 section 690.12 and C22 1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. la ii.Tile IQ 7+Mit=is required to support 7rrt 2-46# adukts - . ... ORTI lkii t.No enforced DC/AC ratio.See the compatibility calculator at https://enphase.co_mienJa/sooporttmodtee-cornpattility. 2.Nominal voltage range can be extended beyond nominal if required by the wilily. MVIRMIR INAS 3.Limits mayvary.Refer to local requirements to define the number of microinverters per branch in your area. . . ENPHASE SHEET NAME To learn more about Enphase offerings,visit - it base,c pm To learn more about Enphase offerings,visit enphase.com n ENPHASE. DATA SHEET N./ .2018 En pna se Energy.A:,rights reserver:.A 1 trademarks or brands used are the property of Enphase Energy,Inn. 2018-05-24 PAGE NUMBER REVISION DS 0 • . , . Enphase IQ Combiner+ BLUE RAVEN Enphase The Enphase 10 Combiner+ with Enphase IQ Envoy' consotidates interconnection MODEL NUMBER 1220 S.630E STE.430 IQCombiner+ IQ Combiner+X-IQ-AM1-240-2 10 Combiner+wrth Endinase li"Q Envoy"far-integrated revenue grade Pyi production metering AMERICAN FORK,UT 84003 equipment into a single enclosure and fAHSI 212.20+I-0.5%)and optional*consumption monitoring 14-.'-2_58), 800-377-4480 (X-1Q-AM1240-2) streamlines PV and storage installations by ACCESSORIES(order separately WWW.BLUERAVENSOLAR.COM Eriphase Mobile Connect" ,, _ CONFIDENTIAL-THE INFORMATION providing a consistent, pre-wired solution for i HEREIN CONTAINED SHALL NOT BE CELLMODEM-03(40/12-year data plan) Fiug ens bay kid'int. nal grade caluiar modem with data icier(for systems up to iti0 i USED FOR THE BENEFIT OF I-i ''-b I i r the US lane da Mexico.Puerto R ico..and the US Virgin isiands, residential applications. It offers up to four CELLMODENNO1(i3G i 5-year data Main) , priori:4 riverteS..,,,,',2.e.$ e_,iiiii i..... ,,,,,,,ii.ce in iinie iinanon an.e.Fii) CELLMODEM-MI MG LTEi CAT-M. I/5-year data Mari where there is adequate i.e.,u-ar kuroi —. rateANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT 2-pole input circuits and Eaton BR series Consumption M ortitoring CT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE CT-200-SPLIT Spirt core current transformers enable Article home consumption metermg*(+/-2.5%) RECIPIENTS ORGANIZATION. bushier assembly. ciiiici.iiit Breakers EXCEPT IN CONNEC TION WITH THE E.RK-154-2-240 Breaker"pule.'I5A_Eaton DB215 SALE AND USE OF THE RESPECTIVE EQUIPMENT WITHOUT THE ERK-20A-2-240 Breaker:2 note 20A,Ea=DR220 WRITTEN PERMISSION OF ELECTRICAL SPECIFICATIONS BLUERAVENSOLAR LLC. Bating Continuous duty D >_ System voltage 240 VAC,50 HZ IJJ --7111j 71- o < i- Eaton ER seri;es busbar rating 115 A (.9 .. mr H., of :::r. < co (..) N. Smart Max.continuous ciirrent rating routout to grid] 55 A Z D 0) < 071- ., . Max.fuse/Mrcuit rating iiciutput) 8i0 A • Includes 10 Envoy for communication 2 F.- In H W 0 . 1— I—. , and control Branch circuits(solar anbior storaga! jp to four 7-pale Eaton ER series Distributed Generation l'0Gi breakers only inot ir)niciuded I Z > CI • C 0 0 < CC) . , .. . . m„...„„ - . .. ......J„.„....„...,„„,,...... • Flexible networking supports Wi-A, Max.co r-.uous current rating(input from P1r) 54A C.) C.) C) Et . ......._ . .. Ethernet.or cellular Max.total branch circuit breaker raT7g(In nut: 80 A k any combination) --) (i) LLI ' + 0 :::-4, :. '' ,,L,',.;,!:,:qiipii:ca , • Provides production metering and optional ' i,I I". iiiti8tnr i IT' Production Metering CT 200 A solid core pre-installed-and wired 70 IC Erriniy Ct _J consumption monitoring CL CCI MECHANICAL DATA Tr, ,„ix,., - i -Lir ii 8 • Supports installation of . .... . , ., Enphase Q Aggregator Dimensions(Wx:HxD) 49:8k 45.5416.0 cm(10i,41 x 18,31x 6.3-i i . .1, . • - i .... . „ i i „.. ..... „.. . .. ., .. . . , . Weight '5 ;(-I 5(5 ilbei i ; 1 .iiiikli. 8_0--- 1. 111 . I: Ambient temperature range -408i C to+4ect,40 ito 1158F) .;;81........ .. Simple Cooling Natural convection,plus hear shield 1181.1,:i ikiii( 1,(,-i 831 ili'in i li i , iretiiilii C.-J.:1' ill i4i7.'''''-1 li''ii 'II:- • Eaton BR series panelboard interior Enclosure environmental ranng Outdoor,NMI, kb:, ' ==iNEMA.type 3R,polycarboriate constructiOn 8.ke i - 1,at 'ii iii.lc 4,; :i::(1,10:t..4,8kii ii - Up to four 2-pole branch circuits for 240 VAC Wire saes • 20 A to 50 A breaker Inputs: 14 to 4 AWG copper conductors plug-in breakers Mot included) - §0 A breaker branch input: 3 to 110 AWG copper conductors 80 A total PV or storage branch circuits Main lug combined output: 10 to 210 AWG copper conductors • . . • Neutral and ground: 14 to 1/0 cooper conductors i . n'ii i1li i-ilik' riP7ii Always follow local code requirements for conductor sizing. . — Reliable Altitude To 2000 meters id1,550 feet) INTERNET CONNECTION OPTIONS - Durable NRTL-certified NEMA type Integrated Wi-Fi 802.11Olgilri 3R enclosure Ethernet 822.3.(1at5E or Cat n'i UTP Ethernet cants-not In,t'lucisd • Five-year warranty Cellular Optional,CELLMDDE M-01 raG)ox CELLMODEM-03 MG)Mot included) • UL listed COMPLIANCE Compliance,Combiner LIL1741 CANICSA 022.2 No.1071 47 CFR,Part 15,Class R,ICES 003 production -..i.r. 'ngANS C12„20 accuracy class 0.5(PV production) LISTED ENPHASE ToCGmPdiancer IQ En'i8Y LIL 916 ,-,1ar-- m 1 cre about Enphase offerings,visit enpftese.com . CAN/CSA C22..2 No.6/010-1 *Consumption monitoring is required for Enphase Storage Systems. To learn more about En. .; -e offerings,visit - ,, ;4•'.COM SHEET NAME A 20,:a Eno) - Eivew 0414n re..,-,k4v8tf 44 tLalk-,n carkt.LI h'sr UN in,1--i doL..',-11 ar,,,...regkree!,:i by ihtil re*, :.r..,-- ENPHASE. DATA SHEET PAGE NUMBER REVISION DS 0 jiiiiji 1E3u AVE, . unnOdule, Plus R Rua SunmoduleYPlus Ii . 1 s W 280-295 MONO BLACK SW 280-295 MONO BLACK 1220S.630E ,U 430 84 :.:_.1r REAL VALUE REAL AMERICAN FORK,UT 84003 t . 800-377-4480 [:[, ° .,, I :.-- ix, " 'vasa a,;-^, d "•vel.::m r<€ PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)= WWW.BLUERAVENSOLAR.COM 5W 280 SW 285 SW 290 SW 295 CONFIDENTIAL-THE INFORMATION Maximum power P,,,� 280Wp 285 Wp 290 Wp 295 Wp HEREIN CONTAINED SHALL NOT BE TUV Power controlled: USED FOR THE BENEFIT OF ^ "" Open circuit a 39.5 V 39.7V 39..9 V 40.0Y ANYONE EXCEPT TUVRh ; a:i Lowest measuring tolerance in industry .. Maximumvolta a V, 31.2 V 313 V 31.4 V 31.5 V BLUERAVENSOLAR NOR SHALL IT power pointg ar BE DISCLOSED IN WHOLE OR IN Short circuit current Ix 9:71A 9.84A 927 A 10.10 A PART TO OTHERS OUTSIDE Moximumpowerpointcurrent I,,,ns 9.07A 9.20 A 9.33 A 9.45.4 RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE _Dmponent is tested to meet Module efficiency rr, 16.70% 17.00% 1730% 17:59% SALE AND USE OF THE RESPECTIVE " -H IEC requirements C ^STC,1000W/rnt 25°C,AM 1.5 EQUIPMENT,WITHOUT THE ��� WRITTEN PERMISSION OF 49 PERFORMANCE AT 800 W/M2,NOCT,AM 1.5 BLUERAVENSOLAR LLC. s. 5W 280 SW 285 SW 290 SW 295 CDMaximum power P,, 207:2 Wp 211.1 Wp 215 Wp 218 4 WpO EL CO iil 11-1Designed to withstand heavy Open circuit voltage V, 35.8V 36.0V 36.2 V 36.3 V z accumulations of snow and ice C dd- H0 OZ manomer. Maximum power point voltage V,,,Pe 28.3 V 28.4 V 28.5V 28.6 V G'1, CO C^.) Q ti zD03 Q Short circuit current Iu 7.85A 7,96A 8,06A 8.17Aer CDQ LU CO Maximum power point current Imp 7.33 A 743 A 7.54 A 7.64 A 2 H l.() H III Q ~ CO z Q Sunmodule Plus. Minorreduction dnefflctencyunder partialload conditions at25`E:at200WJm?100%ofthe SIC effkiency(1000W(ma)Isachieved. O Cr) O (n CO o+zw Positive performance'tolerance COMPONENT MATERIALS W (� U m 'J PA, 1 1000 W/n9 Lo y ------- Cells per module 60 Front es-iron empered glass 0 Soo Wim' with ARC(EN 12150) sta 25 2S-yearlinearperformance warranty Monocr5-bus Hine 25Ill Ce/ltype Frame Black anodized aluminum year3' 600 W,"m' fiusbar gi and 10-year product warranty ,. 6171n x 6.17 in a400 W;mz ` Cell dimensions (156.75 x 156.75m m) Weight 39.7 lbs(18.0 kg) 200 Wirn THERMAL CHARACTERISTICS ADDITIONAL DATA 1 100-W/rn' .. l- ` NOCT 48'C Power sorting -;-)Wpf+S Wp 1110 Glass with anti-reflective coating aM;.een00.a;va Moduleeoltaga(e( V. TCfTCI„ -0.044%JC 1-Box IP65 0004 © TCV„ -031%/C PV wire perLIL4703 37.8(9611 I , Connector with H4/uTX connectors TCP,,,„ -c.43%JC 4.20 I� (106,65). , T ® .Y T Operating temp -40 to+85'C Module fire performance (ILL 1703)Type 1 •a nroa rcc Stzts - 4x U World-loss quality •Sa tyt ta,IK SII30 _ ato - d;e<taow,¢cwosa-z«; �� 7.12 810.26(6.6) Fully-automated production lines and seamless monitoring of the process and mate- a un 8l 4075' leo,8s) rial ensure the quality that the company sets as its benchmark for its sites worldwide. ••eritaKI.common rnict , a IK EA01 C US V =10 0.35(9) PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION UL.1703 1 lot; •eoriaie onteovoo Maximum system voltage SC 11/NEC 1000 V SolarWorld Plus-Sorting •e°""rcontmiSSd o Plus-Sorting guarantees highest system efficiency.SolarWorid only delivers modules �, MO 1r Maximum revenecurrent 25A that have greater than or equal to the nameplate rated power. -, Certified _MO 4011 Number of bypass diodes 3 IC( ❑ .1 ,ti Fen f s0> Design loads' Two rail system 113 psf downward,64 psf upward 25-year linear performance guarantee and extension of product warranty to t0 years o 1 {zer.. t -1 , Design loads• Three rail system 178 psf downward,64 psf upward SolarWorld guarantees a maximum performance digression of 0.7%p.a.in the course ,+ 1 of 25 years,a significant added value compared to the two-phase warranties com- ,m° - Design loads* Edge mounting 178 psf downward,41 psf upward I • mon in the industry,along with our industry first TO year product warranty" 'Please refer-to the sunmodule installation instructions fo rthe details associated with these load cases !o ••I *in accordance with the applicable 5olarWorldLimitedWarranty atpurchase, q 1 crww.solarworld,om/warranty i >00.35(9) •Compatible with both"Top-Down" 0 0 • o and"Bottom"mounting methods 1132 (287501 I • Grounding Locations. 1 1.30(33) I -4 locations along the length of the I---I--- 39:4(1001) I module in the extended flange. 1.30(33) MACE it USAOF US 1 solarworld.com WI IMPORTED PAM'S All units provided are imperial.SI units provided in parentheses. So larWorl4 AG reserves the right to make specification changes without notice, la--114(29)-y.1 SW-01-7515Us 160906 SHEET NAME DATA SHEET PAGE NUMBER REVISION DS 0 . • . • S a eck BLUE RAVEN ,,,,,,.,.....,,...........,..„:„.„.. FLASNEDFV ROOF-MOUNT COMSINER/ENCLOSURE ,.. ........„„.., --- - ,......... _ ...,-- ,-,... . „,..,,* 1220 S 630 E STE 430 AMERICAN FORK,UT 84003 Basic Features - -.-wo,4414.4;,v74-4-4,•.4.....til .....,,,k3.4,:lit,Fog..;:...•:t,.....: ,-.7",77. .1,,,, ,. 800-377-4480 • Stamped Seamless Construction WWW BLUERAVENSOLAR COM P14,14:111/4.0.04Iiit.,:,..IXLITI.If,* • 18 Gauge Galvanized Steel ''''- - , , CONFIDENTIAL-THE INFORMATION ,,17,„ZiatIfaliPs&A,, ,,.• . • Powder Coated Surfaces 44•.:',"''-'1R7.7e7'''!Pligiqe' ' . HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF • Flashes into the roof deck -- - ' - ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT • 3 Roof deck knockouts .5", .75", 1 BE DISCLOSED IN WHOLE OR IN "Iirte,.,klyt.:,, PART TO OTHERS OUTSIDE • 5 Centering dimples for entry/exit .. ,.,.....,,,,,,,,,,,,,,.-- SALE AND USE OF THE RESPECTIVE RECIPIENTS ORGANIZATION, I'- 'II, - ,•II:II,III,I: 4ft fittings or conduit EXCEPT IN CONNEC TION WITH THE .•'. . .,....., • 2 Position Ground lug installed EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF • Mounting Hardware Included BLUERAVENSOLAR LLC. SolaDeck Model SD 0783 L ›- WW ,_ 0 < ,,. SolaDeck UL50 Type 3R Enclosures 0 Z< Ct co 0 0 N: Z D cn < r- Available Models: < 0 1- cC z co. Model SD 0783-(3"fixed Din Rail) i_ in 1— in o — >z c...., H w :01:77r, - . i..'1.-. .• i6i- Model SD 0786-(6"slotted Din Rail) l-- o ' o < Co o o 1: w w .-.. ..„-...„.„ o D fY —.J SolaDeck UL 1741 Combiner/Enclosures Models SD 0783-41 and SD 0786-41 are labeled and ETL listed ULs.STD 1741 according to the UL STD 1741 for photovoltaic combiner enc Max Rated-6°°VDC' 12°AMPS Model SD 0783-41 3"Fixed Din Rail fastened using Norlock System ',,iffM.7-:i11,..,:l'r"4 :'"""`t•i.--f:'-i::::::-.:"-:: **Typical System Configuration ..... . . . ......„„.„,.. , , .,. . ...„.... ..... . „ .. .....„„. ...„ . ... . . .. - - .. ... . 4-Din Rail Mounted Fuse Holders 600VDC 30 AMP ..... ..... :-, . , ..... ...„..„....„,_ 1-Power Distribution Block 600VDC 175AMP ..„ , .,„ 1-Bus Bar with UL lug Model SD 0786-41 6"Slotted Din Rail fastened using steel studs **Typical System Configuration 4-Din Rail Mounted Fuse Holders 600VDC 30 AMP 4-Din Rail Mounted Terminal Blocks Bus Bars with UL lug .:,..„,.. **Fuse holders and terminal blocks added in the field must be UL listed or recognized and meet 600 VDC 30 AMP i , •SONO 10 110C for fuse holders,600V 50 AMP 90C for rail mounted terminal blocks , * and 600 V 175 AMP 90C for Power - .-,.. . ,.. _ ....., Distribution Blocks, Use Copper Wire Conductors. Cover is trimmed to allow Model SD 0783-41,wired with Model SD 0786-41,wired with conduit or fittings,base is Din Rail mounted fuse holders, Din Rail mounted fuse holders. center dimpled for fitting bus bar and power distribution terminal blocks and bus bars. locations, block. SHEET NAME RSTC Enterprises, Inc • 2219 Heimstead Road •Eau Cl/are, WI 54703 DATA SHEET For product information call 1(866) 367-7782 PAGE NUMBER REVISION DS 0 10.... • EN 1. SUN SYSTEM BONDING & GROUNDING BLUE RAVEN Ill a n : FRAME 111 a I I , ri .i Tm ICHORAIL INS ' i Ti , ,, , L _. i rAt. A 10 - 6 ' IDE PAGE AMERICAN FORK,UT 84003 800-377-4480 lumanimim.imirmi 1111111111.1.0111011111011 -.011111111111111111111.1111111111MINMINIIIIMMINIMINIMI 34111/1111111111111.11111111111 0 WWW BLUERAVENSOLAR COM CONFIDENTIAL THE INFORMATION impringimaramor,-"TrrinireraTaimullitAmonamirmvimmam -Aiwa , HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF 1111111 Mal ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE SIM RECIPIENTS ORGANIZATION alill OM EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE ... ri ....... .. ...,.... ..,,,, EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF al a -------,F,.,z_.=------- —,--- - ------=,.... ,„,„.000.0°.# NW : ll „, „ II , 11 , ral BLUERAVENSOLAR LLC 1 Eli 41... ' il - Mir Nam , °Xi Mai. U-I LLI 't 0 1- < 7 0Z 71- H 0 all tall ,e I < Ct c6 1,...: Z D CD < Cf) h.. 11111 •.E. ---_____________ __...„ ____________ ________-____________ _______________=,...........111111 < 0 .1 CtZcYD. NSW :, il ,, • II -, •, --,11 ,,, NM E-W BONDING PATH:E-W module to module bonding 2 1— I-0I- UJ • mai am is accomplished with 2 pre-installed bonding clips 0H co z > cp 01— IN IN I O which engage on the secure side of the MicroraitTM Ma lag and splice. 0 CC D ___I aliii NNW 11 CD 11111111111111111MMINAMIIIIIIIMINIIIIIIIIN Mil MEM 11111111111111111 IMO 1N lam 111111111=mmiiiiiiiiim111111111111111101111111111111111111 MOM IIIIIIIIII 11111111111111 Star Washer is WEEBLUG Single Use Only Single Use Only ...., At: -43A , , - TERMINAL TORQUE, -, Install Conductor and torque to the following: TERMINAL TORQUE, TERMINAL TORQUE, 4-6 AWG: 35ere Jibs Install Conductor and Install Conductor and 8 AWG: 25 55-115s torque to the following, torque to the fallowing: 10-14 AWG:20 in-lbs 4-14 AWG: 3510165 6-14 AWG:7ft-lbs (7) ! i N-S BONDING PATH: N-S system bonding is LUG DETAIL & TORDUE INFO LUG DETAIL & TORQUE INFO LUG DETAIL & TOROUE INFO accomplished through a N-S bonding clip.insert each Ilsco Lay-In Lug (GBL-4DBT) Ilse° Flange Lug(SGB-4) Wiley WEEBLug (6.7) end of the N-S bonding clip onto a module frame • 10-32 mounting hardware • 1/4" mounting hardware • 1/4" mounting hardware flange. System is bonded with a single array edge, • Torque = 5 ft-Lb • Torque = 75 in-Lb • Torque = 10 ft-kb however it is recommended that N-S bonding clips • AWG 4-14-Solid or Stranded • AWG 4-14-Solid or Stranded • AWG 6-14-Solid or Stranded be installed on both edges for ease of maintenance NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION (see also: Maintenance Pane S) System bonding is accomplished through modules. System grounding accomplished by attaching a ground lug to any module SHEET NAME DATA SHEET at a location on the module specified by the module manufacturer. PAGE NUMBER REVISION DS 0 Intertek AUTHORIZATION TO MARK BLUE RAVEN This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) 1220 S.630E STE.430 Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing AMERICAN FORK,UT 84003 Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing 800-377-4480 Report. WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be HEREIN CONTAINED SHALL NOT BE applied only at the location of the Party Authorized To Apply Mark. USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Applicant: Unirac, Inc Manufacturer: JiaxingPacific EnergyEquipment ARPTNTSORGSOZATIOE Corp.R� RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE No. 8 Haiwan Ave SALE AND USE OF THE RESPECTIVE 1411 Broadway Blvd NE Hangzhou Bay Bdao New Area EQUIPMENT,WITHOUT THE Address: Albuquerque, NM 87102 Address: Haiyan Economic Development Area BWLUERAVE SOLAR LITTEN LCF Jiaxing City, Zhejiang Province Country: USA Country: China } p o Klaus Nicolaedis Lili Zeng 0 Z der I - Contact: Jason Mayfield Contact: George Huang Z Ct co UQ O ti 505-462-2190 510-979-1920 Q 0 Lt W o Phone: Phone: 505-400-2949 650-799-7627 I— o FAX: NA FAX: NA H C 0 < 0 klaus.nicolaedis@unirac.com Izeng@ccmfg.com W U U Email: jasonm@unirac.com Email: george@ccmfg.com 0 J Party Authorized To Apply Mark: Same as Manufacturer W m Report Issuing Office: Lake Forest, CA Control Number: 5003278 Authorized by: for Dean Davidson, Certification Manager GUS owmo Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to M ark infer the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authoriz at on to Mark and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sate or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial F actory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL 2703 Issued: 2015/01/28 Ed: 1 Mounting Systems, Mounting Devices, Clamping/Retention Devices, - and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels Photovoltaic Mounting System, Sun Frame Micro Rail- Installed Using Unirac Installation Manual, Rev Product: PUB2017FEB16 Brand Name: Unirac Models: Univac SFM SHEET NAME DATA SHEET ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued: 2-Mar-2017 PAGE NUMBER REVISION ED 16.3.15(1-Jul-16)Mandatory DS 0 ..,_, _ ... ...,.,,..., LIT:, & ASSEM! .DETAILS PAGERAVEN BLUE ORAE I AME MI ' on suNER,-. E TA SHEET TtiditliCAL DA____ THHH, 1220 S.630E STE.430 84003 WW.BLUER I S REQUIRED OR RECOMMENDED W FORK,UT RORAIL I NsTALLATION GUIDE AL FLASHING II.a RAISED SEE------------------- TOO-- ,,, ..:,. MENDED FOR -,....,„,. ., ,,,,, ''''' ''''''s''''' ,„ AMERICAN 800-377-4480 m AVENSOLAR.00 FORM s• ATION • no SONFRAME MIC ING 1 S,INSTALLATION: LAYOUT -----, ' -....., CONFIDENTIAL-THE IN ED SHALL NOT BE SEAL LEASH AA AD-45.D,REER.:.tirl•r.4,.. .7..'s,* IIII6 RAI I •-- :77: ' '''• '' ''''''''''';14Vt:1414{413.41 . 11S14A SED •TAPE MEASURE e 4 , ... ,, HEREIN CONTAINED USED FOR THE BENEFIT OF L IT . . a li * ,•:•_0,,s,, ,,,, '.7..,,,-yM*L.4ri,tNi'ib(,F"-,,,,1,'.*':i *i.,:::'ili'*,,i;.:44,12;•*"ati4N.414,:t14. 71.r44:4 •CHALK LINE , vet A R NOR SHALL EXCEPT CRAYON TOOLS... : NYONE ' •ROOFING -- ' ,„ - • ''' WHOLE OR IN .. NmM11717,74,1.71,Ititit-i-?1,4,'it.44.it.tlf.:*14d,4, 114t. "-' A.***''''''''';1' '" '''''''fi"i7.4.441M1114140.20i4:'4114:040,444Teiirt4,14:47f1,41:ita. •HAMMER DISPENSER '''''''''' 4,44.4‘b - '`••••.-- ''...1?' ',,, PART TO OTHERGANIzATION 116,:it:44,14A.14`13.1q=ji;4,20:?'"ititi:Al-.11,14KY';,:17!: *' .0;1., .,,,,-"st;'fai-$111:*:;;;Mital&*-41,111,140.;JIV:tilitittlZt •COMPATIBLE SEALANT AND GRK AND 31'-'-'s." •' •,.- ,--- .,„,,, , . , RECIPIENTS OR WITH THE -' -4 •DRILL WITH EITHER 1/81BIT FOR v3_ ,,,, .. ,," EXCEPT IN CONNEC TION RESPECTIVE , *447447'.''t USE OF THE R •UNIRAC CUSTOM S TRUCTURAL SCREW OR 2 i ..!%4110•--i1` ' SALE AND WITHOUT THE ,„,.,„ 11 t,„-?zi.,..,:,,,,,„.•,1711.1killiti•-,,,,V,..lbAk.ict*s...'ii'rtititi'" ' 41141"10,:::* EQUIPMENT -tli.itt.• 174,404VsAilltlt FOR LAG BOLT ... ' .... a , PERMISSION OF 'i.",,iliii.-iiii111'12:11. 1"iii11.4.11-''"''yliliArt•-11:7'1'1:H1'1'i* • -N..,,..14,f,14i•i.s.14,.di.,1! BIT (OPTIONAL t4 „„,,,,... ii ',.:.ai••• I ' •Ni. . , . WRITTEN OLAR LLC. , DRIVER WITHW SOCKET pAL , ,. ''''' .... 4 . , ' ' ,A10,1600.. BLUERAVENS 2 ,,, •IMPACT USTOM STRUCTU - NIRAC C , '4' g HEX DRIVER FOR U 4 .i-i . , • • 0 • ,- - co 1.-,..:.-..;.:.-.....• .:.-1;......„7::.,.....,,,,,.,.,•..,,,.:,..i.„1.; ...,, . / ..sk, ,6i,.....e,..i. ,..„..rs 4.14.4„,,,,,.,..,A.,...•2.,Aill.-4,--.4.,,tm..4:, scREM SFM RAISED SEAL S' --,,.,. , COMPONENT • ----,,, ,, • ' . .. , . ›- cj CC --,...,,,,„ '-•• _ -, -.‹,„ r: c...., < ,j . , . , FLASHING UJ .i.. ,...,./ _.1 ...-1,- ""•-•`•,,,,,,•••,-, LU .'' - •'441k,„ -•-• ,,4,•,:,1,,-. • ,...„7,....4,,..,,,i.?„,.., 4 ,•:,..te,,er.4*.e,x,- •,?ke.4., ,---41 z .7r H 0 ''. R: h. 1.FASTENE S/16 J',. ,i,o,....,i,"***" (-9,.• f2 CO (-),... , ,t1:teeqt.ttAitq'•4.*Att.kltrlytititi.4.44:,,,t,..ttAr,:pf of the flashing, 1*'111-1:1fAi11.111.Nri1t117.01*--A*1,If'.e.,,,451L17.17.141.11,141k4NIAb.titk.,4(7,,No,,,, ".!,r,i1`,..41,',44114 ..,1 itti1.4Mi1k,:„Rets./4°;t1 •LAG BOLT 546" 1-1'.• D a) `-4. CO SCREW,S,`-- secure the perimeter — att.and ,iftif:trers,,..N'K,i'''11t44,klif1145414 41,:;:lit,k, ,''',, . ., ,, fri24?4''''''''7'Z14:44 ..7 .1",. .itn.t*. . „4.fi:!!:-..i1;'Ttei,". Vi,,.T.....›:.,, sl.t*.?.T•?,TY,,Is ',t •UNIRAC CUSTOM STRUCTURAL INSTALLATION NOTES: to use nails or other fasteners to d and hgh-definitt ''on composition/asphalt BBL BE ED RI SACVLEONSSEODL AI N z ,..F4 C9 'T UJ o h4.t::.A..::,';'O.;i'k:,vj,,,-:,likrnly,.,:ri4tk..-...•,,':N4y.,,,okittk.4331,141-0-tni...g7,01.44,..4 .GRK STRUCTURAL SCREW.5/18" A.Its not necessary or advisablemade to work with standar n travel — Lc-) I— cp 1-.1;'•-%r'... ..-,..;iigt :.:11i, •-r..t.4*ZrVie'fifIAtt:;Aii...4VV::;;.:-A:4.,:;;-tq:Cfvtif:.Vx.Nt4.9et.gieAL D EDPM SEALING WASHER d Seat Flashio9 is H SLIDER B.The SFM Raise , s..te 5.5firscourses. susceptible to'e damming.ponding water caS OUTSIDE • I— 00 z > 00 '''l; .0, 2.5/16'1 MCLY(VARIOUS)WIT wood shing . le r°°fs'ma' of the roof ('. — 18 co 8 < 3.SEM MOUNT ASSE SHING should not be in bolt penetration. installer. O 0 ii,,,,!../i1iii.,411.'N...?..i i'',: e`;'14:'.'1 fri11%-i4eVifk•44 ;:,..11:•"'"•'''.i.li"1",'",br•ttt"•' RAISED SEAL FLA responsibility of the ILI LU (/) , 4.SFM upward under shingles ' verification are the --) D specification and capacity S.COMP SHINGLE ROOF PG D.Fastener length spec o __I ,. ._ ,....,,,_ r: co OF CONTENTS: 1 TABLE Details 2 0_ Tools&Assembly Installation Quick Steps for PUB2017.1AN11 detetreatcehath[beareas C.Mounts ..." ION ST ,,„P. „.,,, ---vm and E MICROSAIE LLAT QUICK INSTA ,NSTALIG ON Sul lit PALE no SUNDDAM- L I , 1N.c 1 ,...„,„....„,ERDL.,„4„,‘,,,,,, Ii" RA SED SEAL FLASH ' I' ,. , . . ., . L.R.„....„....„ EH::.ELADRARDL7E.L.s. EARLE .....:„..R0 an ' A ' liltz,,fit.:-.4Y;;,-tt;C ;',4,:: ..•'1, :::,- ,-!.2.1,;,,Z.A4T-7.:*',,- -'-'• )y 5 - - ,:-' 2''',.f.F.i: 7''''7.'!"•-•"'',.t. 14=7 : ,•'• ..T.".iRoWitliNIM•' •,-..,,',,..•::' :,4-",:,,t,:r;4• .1';'.:'•:•••'-'47•111- 1,-•,.... , .A.1..Milia.%*:•: .''-' . ' '' ' ''';' •'' . '• ''''''''''..,..":-."1;.'''''' :' -'.'' 'r.:,:rit4,2r16,'it-ii.A;:i''.-9.'7:',-'.' Salr.,:iffft! ,.;.,"••.6.:1'.7', ,,'„,..*:%,",,,, c.,--.'.. -'',•:" - ' — . , ''' • ..:,::---' -'- ' ' . • -At" 'Wftiitag 1Q1. 77'1.•':.;7;r:?:**Piiii ' T.7...,.;.. ,:, .' ''- .. : ON FLASHING: ,:.•.' ":7V.fhigi.! ...te't.2..7:'.-,,•.'-..', ::..-'.::'..(:•.!:-;t:.7-7'::•• ..:.::.: ,.•.-'. - - ' withOPTIONAL SEALANT bead of sealant drle shaped ---:' '-t ' . t.;ii,s.:7"i';1t,iki, •,.:**-N-i1,:i.'•!"*1''''i*s•-*•'' '' **- • *'' T. Fill pilot holeApply a c the drill ROOF sealant hole hardware the attachment _0 ''r ''. '''' DRILL PILOT HOLES: Holding deep pilot a poi opriate of the flashing beforesealant I) INGLES: Use roofing cessioe and square to the i a R eif ra Iflt.er using1/8,, not u„ex PREPARINGakSHsea b e ts between 1stirses. hole into cent71 obit for 5/16-GRK t2anrdliand r2nd and 3rd lsh,i n3sleicood llow a irafitra'x 'sitO•nit'Structura l Zrre5w,106,. Be sure to remove fafila,thaing see,sFm T.32 dirci,dft exten,ion bit / correct Ptacement° 'roper flas"i"n iLg. installation guide forP placement. ii?,0 Allil„: ;.,illcR4b4lll Ailil,:i,Plli'lll'• ";.:'' ---A a.,..,.. - 40 . „: , ..... !,..),I)..?r,';',.'..-..,'1';::''',,7:.7.,-g.:Ifai.,,'4.' ''Ilit ''''''-' ,V14.',.,.;,;:"''''',W ,.:AP,'''4.1"'',"..:',,,.,','-,-,.:,•,;174: , ,,,,,,, A .:....,..,,,„,„,,;,-.,...',........::..=j-i,..••:,..f".„T„..e 7,,..,,,,,..4 . ,,,Iti r.'..,;lNI,4fra::::; `i;,:sll&l,srltllill .'l'lllctiaitilftliNit* RS:;:likjal,,abl"tzill'4,74ali,n, ',',,,l,l,l'j:il.',:r. cv.:l1;!...'4,l44:ncliyi.' :''‘,77'...:,,,,S1"Ji,,,‘:1i...•;iii'.:,.:.1ba.U.01,4.e i.,,,e- ,aililiteigiqiiii ' -Otiiii110t:st1=e174". ' .i-'4'.i.::".'• !,.-4.1,1i11%i10:11iiiiilia.N: - ..- '''.,ie,t,: lc..-'..,...1,:.,,ii.';i3t.;.:: :., `,.:4-',""ii.1* .,:`;',4'!:,s'A.'-'0' ,•----i.---='''.., :,,.:.:,-,7-';e:.-:, 440,n,..,1..k,.....' . • :,i'-:., -••:.,-4,,,„,,,,,-;-:,„„'f',. .!=.4!',1m,.• P.,-....0.1/4ir!' ' .....ii,.1/4t.:,a14,---,,", , :::' -'.: ...'''.,--',.:::1:!, ',.:Y.,..N,?,..r4„..s,--; ': ""'. ,. .'"- •.,„iw.:w..--)""**,'",' INSTALLATION '''‘15..*,..`'•- .• .s47,,,.--,'":',1&;:n.:,," ",, -':• ,, . ,:;:-. . COMPLETE FLASHING s to install, all 'ski,,1*.t,:,';:i.',1i1i't.'11e,,,,,&.2 ', ' • FASTENER & TIGHTEeN. h r Repeat previous stet' SHEET NAME — — slider w" INSTALL FASTENER with sealing properwasher mounts. easily. TA S I-I E E T ,...•-....,,..,,,,,,:,,,.;,;;,,,,, ,,. ....,... ........ pi, SLIDER: Place -li, flute. insia slider to gauge per DA A4•., - -- • the •—-CE over the flashilat on the Swivel tI, driving the fastener, FLASHING: Slide assembly ng REVISION slider sits fl torque when s swiveling POSITION the 2nd course ensuring that the until slider stop NUMBER flashing up underneathtat the bottom edge flashing surface, Tighten PAGE g 0 °f shingles does sof overhantehoef DS of the s own flashinglope edge of the 1st co sdhin g les.