Plans (418) 1 ,, , c\(\ castA-11,1 RTFD EciT, Date: 08/30/2018 SEP Ii 1018 Date of Review: 08/30/2018 CM OF Tit,ARD Project Name: Kelly Gilchrist IVISION Address: 12734 Southwest Morning Hill Court BUILDING D Tigard, Oregon 97223 plans to match new ayout0 Plans have been updated to show new layout. Please reach out to me directly if you have any questions. Scott Gurney Senior Design Manager scott.gurney@blueravensolar.com 385-498-4401 The Future of Energy. Today. BLUE RAVEN GENERAL NOTES AERIAL VIEW _n , _ n n. ,.., .,..,,,, „. .„..,,,,,,, 1. ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE(NEC),2015 , i ::...:;:::::.,::::...1INTERNATIONAL RESIDENTIAL CODE(IRC),2014 NATIONAL BUILDING CODE(NBC).2015 r fr' a INTERNATIONAL BUILDING CODE(IBC),2015 INTERNATIONAL PLUMBING CODE(IPC),AND - '. K. RAVEN ALL STATE AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. � � • 4 '. , £ " 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. z w �p , ten • TO l� .. i �ar F "` ',;:r.'414";_ 1220 S.630E STE.430 I & c a )�` a .. AMERICAN FORK.UT 84003 .... ,-r H u 800-377-4480 SITE NOTES • r • A�� r ,: -� � ,.. - WWW.BLUERAVENSOLAR.COM 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. :17n TTu `"r'7r k • w 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY �E ° " r ' +� CONFIDENTIAL-THE INFORMATION #, ... -w... '�*µ , Y..;4 ,. HEREIN CONTAINED SHALL NOT BE INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. ¢ .. ` " * E=.9! z )+ _ ; Et. USED FOR THE BENEFIT OF 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING.MECHANICAL,OR ,•:',.,„;:;-'5..:11- :.: • I� BUILDING ROOF VENTS. •• �c ,, � ]t ' {� � , uy , AENYONE EXCEPTR 3. ,.:. °E �-.-.w-5 1.: [•�>,,, ,. : ... .. SHALL IT ::... .. 4*-;,--..:r• w BBE DISCLOSED LIN WHOLE OR IN 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL ,, ;e �--� .�+[ E 'n , >.�'� '� u�-` E��•-,;�'. ., ...,,;,,�,� E= -E�_,�a a:.: •:,_ _.,� #. , EQUIPMENT ,v. a r .y.. .EEK 1 * '• , r ;,,v "1...., , ' � ' F> ' °s.a � : B PART TO OTHERS OUTSIDE WILL BE PROVIDED AS PER SECTION[NEC 110.26] �P - �,:.. 4 � ��> `'>�� °->�• "� r � -ar �a �` �' •v, �' �� . ,. ORGANIZATION, 5. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE • �; _,, r.° _: I � : ;,. )" ,0„...„, - " ..,,''',,,,r,, EXCEPT IN CONNEC TION WITH T BETWEEN THE GROUNDING ELECT ; #y. '- "ti' - ,..,.1• ::::::,N ,„. . SA RODE AND THE PANEL(OR INVERTER)IF SMALLER THAN#6 r gi F t< ;,,, E T. �" RESPECTIVE AWG COPPER WIRE PER NEC 250-64B.THE GROUNDING ELECTRODE CONDUCTOR WILL BE -•".e.'. :.-!4'2'.:775t3:14.,,,05„ E c 77513: 4.,,",0"� zr 7• • .}` 'fw :. 4 L EQUIPMENT.WITHOUT THET • WRITTEN PERMISSION OF CONTINUOUS.EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER i4 � � ° BLUERAVENSOLAR. " VENSOLARLLC. [NEC 250.64C.] �:E �' � N ° g 6. ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH ' " k �� • *. . '�" it THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF T ° � rr � 'Y� i nL LIJ O ct a. co COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. • 5�"°� • t , Z 71- O O d� 7. RIGID CONDUIT(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROTECT WIRES. 1 * • *' Q CO C� I� 8. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED ' " rr Z d7 Q J f� CONDUCTOR(USE POLARIS BLOCK OR NEUTRAL BAR) • �S E L riii,i t� Q 0 W 9. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS a - ; ! • • H LL__���� O� DISALLOWED ABOVE LIVE PARTS,MEYERS HUBS RECOMMENDED : [ •• U H C7 Z co (n 00 LLI C) co 10. UV RESISTANT CABLE TIES(NOT ZIP TIES)USED FOR PERMANENT WIRE MANAGEMENT OFF I k " y ' THE ROOF SURFACE IN ACCORDANCE WITH NEC 110.2,110.3(A-B).300.4 } .• .' s 1E IV Er 11.SOLADECK JUNCTION BOXES MOUNTED FLUSH W/ROOF SURFACE TO BE USED FOR WIRE -'" sT•ff , l,MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. t. s s ♦ SOLAR CONTRACTOR ,, a 1 MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,IEC61730. ` r' 2. IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING , .`:' ^w Pt" �'• g����, +, SEP 11 • LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS. .� :::- :. .-::;.:,::::rs':;:?•:::. c� T1 L. r 3. AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED ;; _ ,, . } `" rAT� .... ilk IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION 16L�I � 1S�g. AND APPROVED BYTHEAHJ. ASCE 7-10 WIND SPEED: 110 MPH OCCUPANCY - R3 SHEET INDEX 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND GROUND SNOW LOAD: 10 PSF OFFICE C�PV ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. CONSTRUCTION V B PV1 - COVER SHEET 11 0' 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND EXPOSURE CATEGORY: C ZONING: RESIDENTIAL PV2 - PROPERTY PLAN Z E �, SEALED WITH A SUITABLE SEALING COMPOUND. SEISMIC DESIGN CATEGORY: D O W 6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. PV3 - SITE PLAN N 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ ~ N SCOPE OF WORK PV4 EQUIPMENT & ATTACHMENT DETAIL 2 o a SUITABLE WIRING CUPS. PV5 - ELECTRICAL SINGLE LINE DIAGRAM cc S o 2 8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT AVAILABLE. DC SYSTEM SIZE: 4.35 kW DC PV6 - ELECTRICAL CALCULATIONS uO % 2 H o /A\ 9. ALL INVERTERS,MOTOR GENERATORS.PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS, I ROOF TYPE: Comp Shingle & STRING DIAGRAM Z cn AC PHOTOVOLTAIC MODULES,DC COMBINERS.DC-TO-DC CONVERTERS.SOURCE CIRCUIT - _ 1- COMBINERS,AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER MODULES: (15) Sunmodule Plus SW 290M Black PV7 - MBD CALLS. (IF NEEDED) Lu L r- u) SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(B). INVERTER(S): Enphase 107-60 2 US, PV8 - LABELS & LOCATIONS H - . N U c? 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. u) a_ - F- 0 RACKING: Unirac Sunframe Microrail Mounting & Racking System PV9 STRING & SE OPTIMIZER EQUIPMENT LOCATIONS PV10 - PLACARD (IF NEEDED - NEC 690.56(B)) DRAWING BY 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY[NEC 110.26]. ANCHORED ON MAX 48 INCH CENTERS USING UL LISTED RACKING Marcelo Correa 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING SYSTEM TO SPEC. CITYOPTIGARD • TEMPERATURE AS SPECIFIED BY[NEC 690.31 (A)-(B)]AND[NEC TABLE 310.15(B)]. DATE r 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT R .v l.E.VVL'D TOR ODE COMPLIANCE August 23, 2018 TO THE UTILITY AC DISCONNECT,OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT. s 4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING Approved: PROJECT NUMBER OTC:TO NEC APPLICABLE CODES. t 1 53043842 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE �' WHEN APPROPRIATE. Pernut!F: S - Q D SHEET NAME Address: - 3 `, i 'ra' *.' • COVER SHEET Suite#: B}: MN Date: `a► t L g PA�EPV1 REVISIONO a r LEGEND A\ INV INVERTER&DC DISCONNECTBLUE RAVEN SUB (E) SUBPANEL LC (N) LOAD CENTER M 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 WWW.BLUERAVENSOLAR.COM 95'-7" M UTILITY METER/SERVICE PANEL CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF JB JUNCTION BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE C COMBINER BOX RECIPIENTS ORGANIZATION. EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE PV PV REVENUE METER EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF //, BLUERAVENSOLAR LLC. i{ FIRE SETBACK ©�� -7,111 O EMT CONDUIT RUN W W ( L N (TO BE DETERMINED IN FIELD) Z d' p p _ lklit o T < oo UaN` �, PV WIRE STRING Q �} W M o O o „: � � Hco Zu_ o I-T ❑ ❑ ® MP1 1 PROPERTY LINE I- p p QO in � ;;% Iii! ,.;. AZIMUTH:100° w U U mO ■ ��0 ' PITCH:30° 136'-5" SCALE: 1116"= 1'-0" -C Z ■ �� '• TSRF:77% Ct ° .71- tTh34'-11" pa_ MP4 ,...............,- AZIMUTH:190° /- AZIMUTH:190° ;- i' rill 11:1 ti oUI. TPSITRMFHP:93:155% %IL • AZIMUTH:190° 0; . 01C U PITCH:30° CI oc ■ �-.i _ TSRF:87/0 A z �' MP2 0 AZIMUTH:190° N PITCH:30° ' U) TSRF:93% CC oo o 2 Z 2 } 'S W `. -a CO Ey m M o3 AC DISCONNECT TO BE LOCATED 1 17' u) a_ - p WITHIN 10' OF UTILITY METER DRAWING BY ROOF ATTACHMENTS SHALL BE SPACED Marcelo Correa NO GREATER THAN 24" ON CENTER IN ANY DIRECTION WHERE LOCATED DATE 1 WITHIN 3' OF A ROOF EDGE, HIP, EAVE, August 23, 2018 OR RIDGE OSSC 3111.5.3 ITEM 3.35 PROJECT NUMBER DC SYSTEM SIZE: 4.35 kW DC 53043842 ROOF TYPE: Comp Shingle SHEET NAME (15) Sunmodule Plus SW 290M Black PROPERTY PLAN Enphase IQ7-60-2-US,----INVERTER PAGE NUMBER REVISION PV2 0 r ��\/— ' —\/—\�\/—\/� /�\/`�\/—\/'—\�\/'-- -- . LEGEND INV INVERTER&DC DISCONNECT a ,E RAVEN SUB (E) SUBPANEL - A\ LC (N) LOAD CENTER 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 W W W.BLU E RAV ENSOLAR.COM M AC C N M UTILITY METER/SERVICE PANEL CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF MSP o T JB JUNCTION BOX BLUERAVE SOLAR OR SHALL IT � BE DISCLOSED IN WHOLE OR IN J w> Ck PART TO OTHERS OUTSIDE C COMBINER BOX RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE PV PV REVENUE METER EQUIPMENT,WITHOUT THE �I U WRITTEN PERMISSION OF AilBLUERAVENSOLARLLC. CI U • FIRE SETBACK O '� /// EMT CONDUIT RUN W W O 71- 0 o- • " 40i (TO BE DETERMINED IN FIELD) 0 Z H U // i�:� M P 1 �1�I� .. AZIMUTH:100° Z D rn Q I' iii PV WIRE STRINGw co 12 JB C jj � PITCH:30° Lf) I- o v i PROPERTY LINE U IIGG W. W U U m WO ■ U SCALE: 1/8"= 1'-0" 0 O & ,, JESSEIRMiliiiiiiiiiiiiiii c: 4 8 I' 6,,,,,..11 J oI o AZIMUTH:190° / o J ■ ZH PITCH:15° '4. t TSRF:95% .40 o 0 CC LL // _ z j if, ■ 40) 0 Z 12" 0 M Q I— 2 p2 N Q rn 07 ffc , WJB Et JBp o F O -0 ,c; o ,_CO AC DISCONNECT TO BE LOCATED MP3 f— ti a) 0 co WITHIN 10' OF UTILITY METER AZIMUTH:190° V) o- - I= 0 4 ROOF ATTACHMENTS SHALL BE SPACED PITCH:30° DRAWING BY NO GREATER THAN 24" ON CENTER IN TSRF:87% Marcelo Correa ANY DIRECTION WHERE LOCATED WITHIN 3' OF A ROOF EDGE, HIP, EAVE, DATE M P2 OR RIDGE OSSC 3111.5.3 ITEM 3.35 August 30, 2018 AZIMUTH:190° PITCH:30° PROJECT NUMBER TSRF:93% 53043842 DC SYSTEM SIZE: 4.35 kW DC } ROOF TYPE: Comp Shingle SHEET NAME (15) Sunmodule Plus SW 290M Black SITE PLAN Enphase IQ7-60-2-US,----INVERTER PAGE NUMBER REVISION PV3 0 PV ARRAY STRUCTURAL CRITERIA I PV MODULE COUNT: 15 MODULES PV MODULE(BEHIND TRIM RAIL) Unirac Sunframe Microrail TRIM RAIL #OF ATTACHMENT POINTS: 45 BLUE RAVEN ARRAY AREA: Module Count x 17.51ft2= 262.7ft2 \ ROOF AREA: 1997.6ft2 ,. ~; f % OF ARRAY/ROOF: 13.10 1'-11" N N N N N 1220 S.630E STE 430 ARRAY WEIGHT: Module Count x 50Ibs = 750.0Ibs —MAX. 48"MAX." AMERICAN FORK,UT 84003 0 \ DISTRIBUTED LOAD: Array Weight=Array Area = 2.86 lbs/ft2 800-377-4480 ARRAY DETAIL FRONT VIEW WWWBLUERAVENSOLAR COM POINT LOAD: Array Weight_Attachments = 16.7Ibs/attachment Scale: 3/8" = I-0" CONFIDENTIAL-THE INFORMATION ROOF TYPE: Comp Shingle HEREIN CONTAINED SHALL NOT BE ROOF FRAMING TYPE: Rafter USED FOR THE BENEFIT OF RAFTER OR TOP CHORD SIZE: 2x8 Unirac Sunframe Microrail FRAME ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT RAFTER OR TOP CHORD SPACING: 24"O.C. BE DISCLOSED IN WHOLE OR IN ASCE 7-10 WIND SPEED: 110 MPH EXPOSURE CATEGORY: C CEILING JOIST OR BOTTOM CHORD SIZE: 2x6 PART TO OTHERS OUTSIDE SITE CRITERIA CEILING JOIST OR BOTTOM CHORD SPACING: 24"O.C. EXCEPTRECIPIENTSICONNEC ION WITH GROUND SNOW LOAD: 10 PSF SEISMIC DESIGN CATEGORY: D LNIN USE OF TION THE SFM Raised Seal Flashing �� SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. Unirac Sunframe Microrail UNIRAC TRIMRAILL iiir O LCD 1 Sunmodule Plus SW 290M Black MODULE 300 U' cL i O PV MODULE WIDTH z co ti Q \ WL, Q _ LL0 1 Cco o2 T1 2.5° ARRAY DETAIL, SIDE VIEW W 0 0 00 UNIRAC SLIDERS AND 0 - TRIMRAIL ROOF ATTACHMENTS Scale: 3/8" = 1'-0" O O ar d m U 2.5" MIN. EMBED. FLASHING Q = AC DISCONNECT TO BE LOCATED I- 5/16"STAINLESS STEEL LAG BOLT WITHIN 10' OF UTILITY METER 0 WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER ROOF ATTACHMENTS SHALL BE SPACED o (E) BUILDING NO GREATER THAN 24" ON CENTER IN 0 STRUCTURE ANY DIRECTION WHERE LOCATED WITHIN 3' OF A ROOF EDGE, HIP, EAVE, ca) OR RIDGE OSSC 3111.5.3 ITEM 3.35 ZE O E o N W N Unirac Sunframe Microrail Q _. -. rn ± °'O 1 �' W 0 ST H 0 0Sunmodule Plus SW 290M Black 0 PV MODULE — I o co .th-.. W " co " W N N 0 c� d O o I (E) ROOF r — 2.5" MEMBRANE DRAWING BY L.±1 M �_ Marcelo Correa o ai Ta t" UNIRAC SLIDERS DATE August 23, 2018 J 2.5MIN. EMBED. .• W + FLASHING PROJECT NUMBER p 53043842 5/16"STAINLESS STEEL LAG BOLT = WITH 2-1/2" MIN. EMBEDMENT SHEET NAME AND FLAT WASHER EQUIP. DETAIL (E) BUILDING STRUCTURE PAGE NUMBER REVISION PV4.1 0 11" — 14' 8'-2" 8'-2" 1'-7" BLUE RAVEN LBW BW 1220 S.630E STE.430 0ISTRUCTURALSIDE VIEW AMERICAN FORK,UT 84003 800-377-4480 Scale: 3/8" = 1'-0" WWW.BLUERAVENSOLAR.COM RAFTER: 2x8 @ 24"OC CONFIDENTIAL-THE INFORMATION CEILING JOIST: 2x6 @ 24"OC HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT - BE DISCLOSED IN WHOLE OR IN 141-5" I 3' I PAUTSIDE RECIPIENNTT TO OTHERS STORGANIZATION, 30'-9" EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT.WITHOUT THE Q p_ WRITTEN PERMISSION OF -- 1'-7" 7'-8" 7'-8" — 1'-7" ""- BLUERAVENSOLAR LLC. } O L CO 2 I— LL o U O O U U �`�., RAFTER: 2x8 @ 24" OC o m m CEILING JOIST: 2x6 @ 24" OC ct m LBW i \ STRUCTURAL SIDE VIEW LBW o 2 �/� Scale: 3/8" = 1 '-O" _Ay______ ..-7_ i 0, 15'-8" Z O c\J N b-,1'-3" I 12' 10'-4 — 1'-7" --- 1- 2 — U N O c '/i 0 v ST W U Z z c° › DRAWING BY RAFTER: 2x8 © 24" OC Marcelo Correa CEILING JOIST: 2x6 @ 24" OC DATE y August 23, 2018 PROJECT NUMBER /-- �\ 53043842 rSTRUCTURAL SIDE VIEW SHEET NAME LBW - EQUIP. DETAIL —1 \• __,,) Scale: 3/8" = 1'-0" —i\ PAGE NUMBER REVISION 22'-9" - I PV4.2 0 1 1-5" 6' 2'-4" .erf.-' BLUE RAVEN 1220 S.630E STE.430 AMERICAN FORK,UT 84003 800-377-4480 ,-. WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, . t, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT.WITHOUT THE WRITTEN PERMISSION OF ,,. BLUERAVENSOLAR LLC. Et• } O 00 Q O uJ `'r) U O Zco O CO CO W U U CO IO Ct ... i i <> i CL w: r LBW U 2 Z c O ` m 1 F- N V 2'-4" 2'-4" - 2'-4" U O O 5 - H o - = v°, } w '- `1- I co A ti co O CO STRUCTURAL SIDE VIEW a_ _ i-7- DRAWINGBY 0Marcelo Correa DATE August 23, 2018 RAFTER: 2x8 @ 24" OC PROJECT NUMBER 53043842 CEILING JOIST: 2x6 @ 24" OC SHEET NAME EQUIP. DETAIL PAGE NUMBER REVISION PV4.3 0 0(1) 10 AWG THWN-2,COPPER,BLACK(LINE 1) 1&0 A AC (2) 10 AWG THWN-2,COPPER,RED(POSITIVE) MAX 10.0 A AC (1) 12-2UF-B WIG,SOLID COPPER MAX 10.0 A AC • (1) 12-2 TC-ER,THWN-2,COPPER MAX 10.0 A AC (1) 10 AWG THWN-2 COPPER,RED(UNE 2) 240 V AC (2) 10 AWG 7HWN-2,COPPER,BLACK(NEGATIVE) 240 V AC 2 240 VAC 1 (1) 10 AWGTHWN-2,COPPER,WHITE(NEUTRAL) (1) 10 AWG TIiWN-2,COPPER,GREEN(EGO (1} 6 AWG BARE,COPPER(EGC} 240 V AC (1) 10 AWGTHWN-2,COPPER,GREEN(GROUND) BLUE RAVEN (1) 3/4 INCH EMT CONDUIT (1) 3/4 INCH EMT CONDUIT 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 800-377-4480 WWW.BLU E RAVENSOLAR.COM (15)Sunmodule Plus SW 290M Black CONFIDENTIAL-THE INFORMATION UL 1703 COMPLIANT HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ALL CONDUIT TO BE RAN AT LEAST 7/8"ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT. (15)Enphase IQ7-60-2-US MICRO INVERTERS ANYONE EXCEPT UL 1741 COMPLIANT BLUERAVENSOLAR NOR SHALL IT 5 MODULES MAX FOR ALL SUB-BRANCH BE DISCLOSED IN WHOLE ORL INI CIRCUIT(S)TO COMPLY WITH VRISE CALCS PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, ENPHASE IQ COMBINER EXCEPT IN CONNEC TION WITH THE X-I Q-AM 1-240-2 (SOLAR LOADS ONLY) JUNCTION BOX JUNCTION BOX SALE AND USE OF THE RESPECTIVE (E)200A MAIN SERVICE PANEL EQUIPMENT,WITHOUT THE 1111 WRITTEN PERMISSION OF (N)20A/2P _ ( ) ��II � BLUERAVENSOLAR LLC. (E)200A/2P MAIN BREAKER 1 CIRCUIT a 0111) PV AC DISCONNECT - 1,;:i.,.....,....._76_,_2(N)20A/2P � `2 n L2 1).4 OF 10 MODULES I� Im © } O (E)200A/2P NON-FUSED W O O LOCKABLE,VISIBLE OPEN G � G LU Z O O 30A,240V,2-POLE —" V V 4 0 CF)W CO 0 D r- (E)LOADS Z < J ti CO cV �� O JUNCTION BOX �-' z L . O A a D (N)25A/2P /} — N 20A2P I (1) CIRCUIT a� ~ Q M O O ��o " / \---00,, ..,.� 0,, n f\ ( ) u u u OF 8 MODULES W U („� m —�10 NZ o o �z o�� «L2 �z L2 I� '' CO N G 120/240 VAC v1(IVB 60HZ a ' TO UTILITY _ GRID 5 O O 1 't PV BREAKER TO BE LOCATED OPPOSITE END OF BUSSING FROM MAIN BREAKER U (E) GROUNDING ELECTRODE I Z •- M O . . o N T Q 1 I` 2 o CD O 2 IN 1 N L 2 O v INTERCONNECTION NOTES LL O Lo 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF ! ._. —z = 0 BUSBARS AND PANELBOARDS. (a)THE SUM OF 125 PERCENT OF THE INVERTER(S)OUTPUT ...F zco cz Lo ..m -ii:ri ' CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b)WHERE TWO SOURCES, ;;::;NN,N ` t U) I— 0 t- C7 M ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF I N x :11taHDRAWING BY BUSBAR THAT CONTAINS LOADS,THE SUM OF 125 PERCENT OF THE INVERTER(S)OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE i; a5 Marcelo Correa BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR 3 �_ j!il •11 .' I 705.12(D)(3)]. [NEC[ 3. GROUND FAULT PROTECTION IN ACCORDANCE WITH[NEC 215.9]&[NEC 230.95] • a DATE August 23, 2018 4. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. i o;�y+��.` G , z„ ,�, � "` ' PROJECT NUMBER DISCONNECT NOTES 53043842 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE . `il..�Y -• • SHEET NAME TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS) f - • ELEC. 3 LINE DIAG. 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH 9 �y PAGE NUMBER REVISION 3. DC CURRENT CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO EITHER A FUSEABLE SOURCE CIRCUIT PV5 0 , ,NiNgim,„ BLUE RAVEN MODULE SPECIFICATIONS Sunmodule Plus SW 290M Black DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS 1220 S.630 E STE.430 RATED POWER(STC) 290 W TEMPERATURE DATA SOURCE ASHRAE 2%AVG. HIGH TEMP MICROINVERTER TO ,AAX.SHORT CIRCUIT CURRRENT(ISC)= 10.0 A AC AMERICAN FORK,UT 84003 MODULE VOC 40 V DC STATE Oregon JUNCTION BOX MAX. CURRENT(ISC X1.25)= 12.5 A AC 800-377-4480 WWW.BLUERAVENSOLAR.COM MODULE VMP 31 V DC CITY Tigard CONDUCTOR(TC-ER, COPPER(90°C))= 12 AWG MODULE IMP 9.3 A DC WEATHER STATION PORTLAND INTERNATIONAL AP CONDUCTOR RATING= 30 A CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE MODULE ISC 10 A DC ASHRAE EXTREME LOW TEMP(CC) -61 AMB.TEMP.AMP.CORRECTION= 0.96 USED FOR THE BENEFIT OF ANYONE EXCEPT VOC CORRECTION (%/°C) -0.3 °C ASHRAE 2%AVG. HIGH TEMP(°C) 32 ADJUSTED AMP.= 28.8 > 12.5 BLUERAVENSOLAR NOR SHALL IT VMP CORRECTION % °C -0.4 °C JUNCTION BOX TO ✓IAX.SHORT CIRCUIT CURRRENT ISC = 10.0 A AC BE DISCLOSED IN WHOLE OR IN ( / ) ( ) PART TO OTHERS OUTSIDE SERIES FUSE RATING 25 A DC SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 CIR 2 CIR 3 CIR 4 CIR 5 CIR 6 COMBINER BOX MAX.CURRENT(ISC X1.25)= 12.5 A AC RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE ADJ. MODULE VOC @ ASHRAE LOW TEMP 43.7 V DC NUMBER OF MODULES PER MPPT 10 8 INDUCTOR(THWN-2, COPPER(90°C)) = 12 AWG SALE AND USE OF THE RESPECTIVE ADJ. MODULE VMP @ ASHRAE 2%AVG. HIGH TEMP 26.0 V DC DC POWER RATING PER CIRCUIT(STC) 2900 2320 CONDUCTOR RATING= 25 A EQUIPMENT, TTHE WRITTEN PERRMISSIMISSI ON OF TOTAL MODULE NUMBER 18 MODULES CONDUIT FILL DERATE= 1 BLUERAVENSOLAR LLC. MICROINVERTER SPECIFICATIONS Enphase IQ7-60-2-US STC RATING OF ARRAY 5220W DC AMB.TEMP.AMP.CORRECTION= 0.96 L >- o L 0 p POWER POINT TRACKING(MPPT) MIN/MAX 22 - 48 V DC AC CURRENT @ MAX POWER POINT(IMP) 10.0 8.0 ADJUSTED AMP.= 24 > 12.5 W LU d O .71- MAXIMUM INPUT VOLTAGE 48 V DC MAX.CURRENT(IMP X 1.25) 12.5 10 EGC ISC= 10.0 A AC MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 20 I MAX. CHANNEL ISC= 12.5 A AC Z D co < -I N- MAXIMUM USABLE DC INPUT POWER 350 W MAX.COMB.ARRAY AC CURRENT(IMP) 18.0 INDUCTOR(THWN-2, COPPER(90°C))= 10 AWG 2 I- Lc) I- LI o MAXIMUM OUTPUT CURRENT 1 A AC MAX.ARRAY AC POWER 4320W AC EGC CONDUCTOR RATING= 20 A H cc Z cp AC OVERCURRENT PROTECTION 20 A CONDUIT FILL DERATE= 1 W O O m MAXIMUM OUTPUT POWER 250 W AC VOLTAGE RISE CALCULATIONS DIST(FT)✓RISE(V) VEND(V) %VRISE IQ7-5 AMB.TEMP.AMP.CORRECTION= 0.96 -) CO CEC WEIGHTED EFFICIENCY 97 % VRISE SEC. 1(MICRO TO JBOX) 18 0.36 240.36 0.15% ADJUSTED AMP.= 19.2 > 12.5 O CC VRISE SEC. 2(JBOX TO COMBINER BOX) 30 1.21 241.21 0.51% COMBINER BOX TO INVERTER RATED AMPS= 18.0 A AC El AC PHOTOVOLATIC MODULE MARKING(NEC 690.52) VRISE SEC. 3(COMBINER BOX TO POI) 10 0.46 240.46 0.19% MAIN PV OCPD MAX.CURRENT(RATED AMPS X1.25) = 22.5 A AC - NOMINAL OPERATING AC VOLTAGE 240 V AC I TOTAL VRISE 0.85% INDUCTOR(THWN-2, COPPER(75°C))= 10 AWG NOMINAL OPERATING AC FREQUENCY 47-68 HZ AC CONDUCTOR RATING= 35 A MAXIMUM AC POWER 240 VA AC PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL(NEC 690.54) CONDUIT FILL DERATE= 1 z MAXIMUM AC CURRENT 10.0 A AC AC OUTPUT CURRENT 18.0 A AC ; AMB.TEMP.AMP.CORRECTION= 0.96 U MAXIMUM OCPD RATING PER CIRCUIT 20 A AC NOMINAL AC VOLTAGE 240 V AC ADJUSTED AMP.= 33.6 > 22.5 2 GROUNDING NOTES 10. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO[NEC 6. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 . . 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690-47]AND 690.45] AND BE A MINIMUM OF#10AWG WHEN NOT EXPOSED TO DAMAGE(#6AWG INSULATED. 90°C RATED,WET AND UV RESISTANT, RATED FOR 600V Z Eco� [NEC 250-50]THROUGH[NEC 250-60]SHALL BE PROVIDED. PER NEC, SHALL BE USED WHEN EXPOSED TO DAMAGE). 7.4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER O 0 (N W GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND 11.GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. ~ 2 CNIN BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, CODED GREEN(OR MARKED GREEN IF#4 AWG OR LARGER) 8.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION 2 U N CO OR INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL 12. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF 9.VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS Ct 0 } 0 2 GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 10. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS 0 8 W 0 CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 13.SYSTEM GEC SIZED ACCORDING TO[NEC 690.47], [NEC TABLE 250.66], DC FOLLOWS: DC POSITIVE-RED(OR MARKED RED), DC NEGATIVE-GREY(OR MARKED GREY) Z (p O 2. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN#8 AWG AND SYSTEM GEC SIZED ACCORDING TO[NEC 250.166],MINIMUM#8AWG WHEN 11. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: - CD 2 - >- �S NO GREATER THAN#6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING INSULATED,#6AWG WHEN EXPOSED TO DAMAGE. DC POSITIVE-GREY(OR MARKED GREY), DC NEGATIVE-BLACK(OR MARKED BLACK) W N 2 (/) - ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 14. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES. 12.AC CONDUCTORS>4AWG COLOR CODED OR MARKED: ~ c\J o) 0 c 3. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO(NEC 250.21].[NEC TABLE EQUIPMENTS,AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN PHASE A OR L1-BLACK, PHASE B OR L2-RED, PHASE C OR L3-BLUE, NEUTRAL- U) D_ r F- 0 4 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO[NEC ACCORDANCE WITH 250.134 OR 250.136(A)REGARDLESS OF VOLTAGE. WHITE/GRAY DRAWING BY 690.46]. *USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY Marcelo Correa 4. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC WIRING&CONDUIT NOTES BE USED INSIDE 690.42]. 1.ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND `*USE-2 IS AVAILABLE AS UV WHITE - 5. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT APPROVED FOR THE SITE APPLICATIONS 13. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL DATE THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR 2.ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR BE EITHER EMT, FMC,OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31,NEC August 23, 2018 TO ANOTHER MODULE. CABLE LISTED AND IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT; ROUTED TO 250.118(10). DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 6. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS SOURCE CIRCUIT COMBINER BOXES AS REQUIRED 14.CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE PROJECT NUMBER IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 3.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC COMPLYING WITH NEC 230.6(4)AND SECURED NO GREATER THAN 6'APART PER NEC 53043842 7. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH 690.8] FOR MULTIPLE CONDUCTORS 330.30(B). AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION 4.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED SHEET NAME GROUNDING LUGS. AT LEAST 7/8"ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO[NEC TABLE ELEC. CALCS. 8. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND 310.15(B)(2)(a), NEC TABLE 310.15(B)(3)(a),&NEC 310.15(B)(3)(c)]. GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 5. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90°C RATED,WET AND UV PAGE NUMBER REVISION 9. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR RESISTANT,AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE PV6 STRANDED,AND BARE WHEN EXPOSED. USED TO PROTECT WIRE FROM SHARP EDGES pHoTovoLTAIC L 1 LABEL 7 _ s s - FOREPV DISCONNECTING MEANS WHERE ALL AT DIRECT-CURRENT EXPOSED RACEWAYS.CABLE TRAYS,COVERS AND ENCLOSURES OF JUNCTION BOXES,AND OTHER TERMINALS OF THE DISCONNECTING MEANS MAY BE WIRING METHODS,SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES,WALLS,PARTITIONS, ELECTRIC SHOCK HAZARD ENERGIZED IN THE OPEN POSITION. CEILINGS OR FLOORS. "L U RAVEN TERMINALS ON THE LINE AND [NEC 690.13(B),NEC 705.22] � �ER � �� � [NEC 690.31(G)(3&4)] LOAD SIDES MAY BE ENERGIZED —,„.„ IN THE OPEN POSITION — LABEL 8 LABEL 11 SOLAR PV SYSTEMEQUIPPED FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY q /� PERMANENT DIRECTORY TO BE LOCATED AT 1220 S.630 E STE.430 Z WITH RAPID SHUTDOWN AND CONDUCTORS LEAVING THE ARRAY: MAIN DISTRIBUTION UTILITY DISCONNECT(S) MAIN SERVICE EQUIPMENT LOCATION IF ALL AMERICAN FORK.UT 84003 SIGN TO BE LOCATED ON OR NO MORE THAN 3 LABEL 2 TURN RAPID SHUTDOWN POWER To THIS BUILDING IS ALSO SUPPLIED ELECTRICAL POWER SOURCE DISCONNECTING CH E T C ENT FT AWAY FROM SERVICE DISCONNECTING 800-377-4480 AT EACH DC DISCONNECTING MEANS,INCLUDING THE SNATCH TO THE FROM A RooF MOUNTED SOLAR ARRAY WITH MEANS (SOLAR ARRAY RAPID SHUTDOWN DFPPDSITIONTD �,a MEANS TO WHICH THE PV SYSTEMS ARE A RAPID SHUTDOWN DISCONNECTING MEANS WWW.BLUERAVENSOLAR.COM DC DISCONNECT AT THE INVERTER” SWITCH)ARE GROUPED AND IN LINE OF SITE OF PHOTOVOLTAIC P( RSOUR SHUTDDYVNPVSYSTEM CONNECTED AND SHALL INDICATE THE GROUPED AND LABELED WITHIN LINE OF SITE [NEC 690 53 NEC 690.13(B)] AND REDUCE -1- LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN AND 10 FT of THIS LOCATION MAIN SERVICE DISCONNECTING MEANS. CONFIDENTIAL-THE INFORMATION SHOCK HAZARD [NEC 690.56(C)&NEC 705.10]. HEREIN CONTAINED SHALL NOT BE �„,IN — SWITCHES IF NOT AT THE SAME LOCATION. USED FOR THE BENEFIT OF MAXIMUMVOLTAGE [NEC 690.56(C)(1)(A)] ANYONE CIRCUIT CURRENT AMPS EXCEPT BLUE RAVEN "».. SOLAR NOR SHALL IT BE LABEL 9 1k ° PERMANENT DIRECTORY TO BE LOCATED AT DISCLOSED IN WHOLE OR IN PART SOLAR PV SYSTEMEQUIPPED FOR PV SYSTEMS THAT ONLY SHUT DOWN SOLAR ARRAY RAPID SHUTDOWN SWITCH POWER TO THIS BUILDING IS ALSO TO OTHERS OUTSIDE RECIPIENTS LABEL 3 RAPID SLID CONDUCTORS LEAVING THE ARRAY: DENOTING THE LOCATION OF THE SERVICE ORGANIZATION,EXCEPT IN PHOTOVOLTAIC SYSTEM SIGN TO BE LOCATED ON OR NO MORE THAN 3 SUPPLIED FROM MAIN DISTRIBUTION EQUIPMENT LOCATION IF SOLAR ARRAY RAPID CONNECTION WITH THE SALE AND FT AWAY FROM SERVICE DISCONNECTING UTILITY DISCONNECT LOCATED INSIDE SHUT DOWN DISCONNECT SWITCH IS NOT USE OF THE RESPECTIVE DISCONNECTINGATPOINTOF MEANS.INTERCONNECTION,MARKED AT AC TR2P1 RAPID TOTHE'GFFPCSETIQN ® MEANS TO WHICH THE PV SYSTEMS ARE BUILDING IN__ __ GROUPED AND WITHIN LINE OF SITE OF MAIN EQUIPMENT,WITHOUT THE AG DISCONNECT [NEC 690.54.NEC 690 13(B)] TD THE Y°95 E :; CONNECTED AND SHALL INDICATE THE SERVICE DISCONNECTING MEANS. WRITTEN PERMISSION OF BLUE RATED ACOIJTPUTCIJRRENT A CONDUCTORS WITHIN i LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN [NEC 705.10] RAVEN SOLAR LLC. ENERGREDINSuNUGHT SWITCHES IF NOT AT THE SAME LOCATION. _ NOMINAL OPERATING AC VOLTAGE V - [NEC 690.56(C)(1)(B)] 1► LABEL 13 L > O L {f3 FO '' '•' PERMANENT DIRECTORY TO BE LOCATED AT MAIN W Z .1- O O 'Sr LABEL 4 LABEL 10 '71- POWER TO THIS BUILDING IS ALSO SUPPLIED OF T HIE PVINGCE MEANS.PMENT GROUSYSTEM ENOTING THE LOCATION (� F i 3 1 SIGN LOCATED AT RAPID SHUT DOWN FROM ROOF MOUNTED SOLAR ARRAY SOLAR Z D ON- T AT POINT OF INTERCONNECTION FOR EQUIPMENT I .r I n .. i 1 r ARRAY RAPID SHUTDOWN DISCONNECT Is DISCONNECTING MEANS IF SOLAR ARRAY RAPID Z CD < 0 C 7 CONTAINING OVERCURRENT DEVICES IN CIRCUTS E ) DISCONNECT SWITCH[NEC 690.56(C)(3)[. SHUT DOWN DISCONNECT SWITCH IS NOT < 0 CL W SUPPLYING POWER TO A BUSBAR OR CONDUCTOR ' i ' LOCATED OUTSIDE NEXT To UTILITY METER. GROUPED AND WITHIN LINE OF SITE OF MAIN H Lf) I— LL O DUAL POWER SUPPLY SUPPLIED FORM MULTIPLE SOURCES,EACH SERVICE SOLAR PV !.--(S : SERVICE DISCONNECTING MEANS"[NEC 705.10. I— C Z 0 � SOURCES:UTILITY GRID AND EQUIPMENT AND ALL ELECTRIC POWER PRODUCTION NEC 690.56(C)(1)] U O O , PV SOLAR ELECTRIC SYSTEM SOURCE LOCATIONS LL1 U 0 m [NEC 705.12(B)(3)l LABELING DIAGRAM FOR MICRO INV.: 0 1 LABEL 5 MAIN SERVICE PANEL a s ),', 1 PLACED ADJACENT TO THE BACK-FED BREAKER EXISTING SUB PANEL PV COMBINER °, FROM THE INVERTER IF TIE IN CONSISTS OF LOAD { 1 ) O (IF WHERE POINT OF SUBPANEL- INVERTER OUTPUT CONNECTION SIDE CONNECTION TO BUSBAR. �✓ INTERCONNECTION IF USED TO COMBINE AC JUNCTION BOX [NEC 705.12(B)(2)(3)(b)] /n1 IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS OR AC COMBINER BOX DO NOT RELOCATE �*� �� THIS OVERCURRENT ❑ ❑ 0g OR®g 0 03 `, ® t_1 o DEVICE U (� 0O° 11 OR 13 �-' OR PLACARD 12 OR 11 CY) 36 ';',;;; ;Y;".: (ONLY IF 3 OR MORE SUPPLY SOURCES TO PLACARD z C A BUSBAR) 5 5 o E M SIGN LOCATED AT LOAD CENTER IF IT (ONLY PV (ONLY PV ° 0 8 (N W THIS EQUIPMENT FED BY MULTIPLE CONTAINS 3 OR MORE POWER SOURCES ( NTERCONNECTION IF I,- N SOURCES.TOTAL RATING OF ALL [NEC 705.12(B)(2)(3)(C)] INTERCONNECTIONQ Y N 07 CONSISTS OF LOAD CONSISTS OF LOAD 2 U N = OVERCURRENT DEVICES.EXCLUDING SIDE BREAKER) SIDE BREAKER) C[ O p MAIN SUPPLY OVERCURRENT O Y LLJ DEVICE.SHALL NOT EXCEED I L -r0 o H o Z LABELING DIAGRAM FOR STRING INV /DC OPTIMIZER INV.: (I)� COQ (n AMPACITY OF BUSBAR. = n _ } MAIN SERVICE PANEL — O ( EXISTING SUB PANEL PV COMBINER INVERTER(S) ot co a 1.0 1 3 (IF WHERE POINT OF SUBPANEL- U5 , CNI f7 a 4 � • • §F ' LABEL 11 INTERCONNECTION IF USED TO COMBINE - = a a, � ' T R n SIGN LOCATED AT AC COMBINER BOX FOR 04 IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS . eK ALL MICRO-INVERTER 1 AC MODULE DRAWING BY INSTALLS(IF APPLICABLE). ° ❑ O Marcelo Correa OR RAPID SHUTDOWN TEST ® 0 0 0 00 NOT REQUIRED ° ° 11 OR 13 �`� DATE August 23, 2018 OR PLACARD 12 OR {6 ) t JUNCTION BOX OR COMBINER BOX g LABELING NOTES: LACARD DC t LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO 11 PROJECT NUMBER DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND (ONLY IF PV (ONLY IF PV - ° 053043842 o MAKE APPROPRIATE ADJUSTMENTS. INTERCONNECTION NTERCONNECTION 10 O 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE,OSHA STANDARD CONSISTS OF LOAD CONSISTS OF LOAD °-° ® 19010.145,ANSI Z535. SIDE BREAKER) SIDE BREAKER) ®2 SHEET NAME 3. MATERIAL BASEDOF ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. LABELS /� 4 LABELS TO BE SUFFICL IENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED[NEC INTEGRATED DC DISCONNECT /-1 L�7 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8",WHITE ON RED BACKGROUND:REFLECTIVE, `ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PAGE NUMBER REVISION AND PERMANENTLY AFFIXED[IFC 605.11.1.1] PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM" PV5 LINE DIAGRAM TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. PV$ 0 BLUE AAA ON POWER TO THIS BUILDING IS ALSO SUPPLIED FROMAMERICAN FORK,UT 84003 ROOF MOUNTED SOLAR ARRAYS WITH SAFETY 800-3774480 DISCONNECTS AS SHOWN : WWW BLUERAVENSOLAR COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE RAPID SHUTDOWN AC USED FOR THE BENEFIT OF w ANYONE EXCEPT DISCONNECT SWITCH BLUERAVENSOLAR NOR SHALL IT Q ©®MN BE DISCLOSED IN WHOLE OR IN = PART TO OTHERS OUTSIDE 112 A RECIPIENTSZATI EXCEPT IN CONNEC EC TION WITH THE SALE AND USE OF THE RESPECTIVE 0 1 le. 1 EQUIPMENT,WITHOUT THE F-- WRITTEN PERMISSION OF BLUERAVENSOLAR LLC Z II r AV li W >- LcnoAil OZ � 0Ofl � < ( S W C) MAIN DISTRIBUTION 1- 03 z c) UTILITY DISCONNECT o U 0 O w Cm, UJO Om0 -' CO 120QFAM 0 i '‘' 0_ PV ARRAY t 12734 SOUT-WEST MORNING HILL COURT, TIGARD, OREGON 97223 0 DIRECTORY 0 N w PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION Q -t N OF THE SERVICE DISCONNECTING MEANS AND THE 2 8 3 0 O & - CD W 0 PHOTOVOLTAIC SYSTEM DISCONNECTING. o WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH z = cn o } OTHER, A DIRECTORY I SHALL BE INSTALLED AT EACH DC PV w L' J SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING cn i— a r-- a O 4 MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS DRAWINGBY SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM Marcelo Correa DISCONNECTING MEANS IN THE BUILDING. ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC DATE August 23, 2018 _ ENGRAVE IN CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED USING AN APPROVED METHOD. IF EXPOSED PROJECT NUMBER TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND 53043842 SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC. . SHEET . [NEC 690.56(B)&(C)] [NEC 705.10]. PLACARD PAGE NUMBER REVISION PV10 0 ta She-et BLUE RAVEN Da Enph.wx Microinverters - P.egior- ,k,Jf EP IC AS - 1220 S.630 E STE.430 Enphase IQ 7 and IQ 7+ Microinverters AMERICAN FORK,UT 84003 800-377-4480 INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/1Q7PLUS-72-B-US WWW.BLUERAVENSOLAR.COM Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules CONFIDENTIAL-THE INFORMATION Maximum input DC voltage 48 V 60 V HEREIN CONTAINED SHALL NOT BE The -Igh-pc,-,,•;,-.--..red smart grid-ready USED FOR THE BENEFIT OF haSe Eh ,..1-3.e 107 tvlicro- and Enphase IQ 7+ Micro- Operating range 16 V-48 V Peak power tracking voltage 27 V-37 V 27 V-45 V 16V-60V ANYONE EXCEPT EnP BLUERAVENSOLAR NOR SHALL IT IQ 7 and IQ 7+ dra--iatically simplify the installation process while Min/Max start voltage Max DC short circuIt current(module isc) 22 V/48 V 15 A 22 V/60V 15 A BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, achieving the highest system efficiency. Overvoltage class DC port II II EXCEPT IN CONNEC TION VVITH THE M ' • 0 A 0 A SALE AND USE OF THE RESPECTIVE 1 croinverters Part of the Enphase I0 System,the IQ 7 and DC port backfeed current PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; EQUIPMENT,WITHOUT THE AC side protection requires max 20A per branch circuit WRITTEN PERMISSION OF IQ 7-1- Microinverters integrate with the Enphase BLUERAVENSOLAR LLC. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter IQ Envoy ,Enphase IQ Battery ,and the Enphase Peak output power 250 VA 295 VA Enlighten-. monitoring and analysis software. Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltagerange 240 V I 208 V/ 240 V/ 208 V/ W ;II :Z o 211-264 V 183-229V 211-264 V 0 ..._. -1 1._ - .1- IQ Serres Microinverters extend the reliability Maximum continuous output current 1.0 2(240 V) 1.15 A(208 V) 1.21 A(240 V) 183-229 V 1.39 A(208 V) < Ct co 0 0 irs.: standards set forth by previous generations and Nominal frequency 60 Hz 60 Hz co. Extended frequency range 47-68 Hz 47-68 Hz undergo over a million hours of power-on testing, 2 I_ in F- LI..1 0 AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms I- C° Z > 0 enabling Enphase to provide an industry-leading Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) t 11- o c' o < warranty of up to 25 yearsOvervoltage class AC port III III LL1 (-) 0 Cr _ '.- AC port backfeed current 0 A 0 A -) 0) W Power factor setting 1.0 1.0 0 -J Power factor(ad)ustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging 0_ CO EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 976 v 97.6%------ 975% 97,3",.. ---------------- - CEC weighted efficiency 97.0% 97.0''''-; 97.0% 97.0% EasyMECHANICAL DATA to Install Ambient temperature range -40°C to+65°C ,1414'11 '44'al..;:4'"P • lightweight and simple Relative humidity range 4%to 100%(condensing) '11h:Ef.ii,14'i' ",ia.g-t'"-: ;,'''',' • Faster ingtaltation with irripnoved,;'i., • two-wire cabling Connector type(IQ7-60-2-US 8,IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) ,:iSti,iii.APt ...IW1IM 'i: Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable) ,,E;.,„AN, ' • Built-in rapid shutdown compliant(NEC 2014&2017) Adaptors for modules with MC4 or UTX connectors: -PV2 to MC4:order ECA-S20-S22 F Ili _PV2 to UTX:order ECA-S20-S25 it 1 Productive and Reliable Dimensions(WxHxD) 212 mm x 175 mm x 30.2 irim(without bracket) .1z ' --- Weight 1.08 kg(238 lbs) • •..'rricz' ed for high powered 60-cel and 72-cetl*modules Cooling Natural convection No fans • More than a million hours of testing Approved for wet locations Yes • Class II .. ..le-insulated enclosure Pollution degree PD3 ' • Ii listed Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Smart Grid Ready Communication --- Power Line C;nrnoniCailOO(PLO)---- ------ Monitoring Enlighten Manager and MyEnlighten monitoring options. • Complies with advanced grid support.'voltage and Both options require installation of an Enphase IQ Envoy 41 frequency ride-through requirements Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break ow • Remotely ,i..tea to respond to oh-...ing disconnect required by NEC 690 grid requirements Compliance CA Rule 21(UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B. • Configurable for varying grid profiles CAN/CSA-C22.2 NO.107.1-01 - • Meets CA Rule 21 (LJL 1741-SA) This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. z glijil 'Th e IQ 7+1.44cro rs nequeed to support 72-cell modules. t IPlie 1.No enforced DC/AC ratio.See the cornpallbility calculator at Ltlips://enott.asokinIen-AVsinvolknod_ole-_co_mpa.t.:.......... 2.Nominal voltage range can be extended beyond nominal if recuired by the uflity. memo MUM 3.Limits may vary.Refer to local rer,11 remenls to define the number of mreroinverters per branch in your area. ENPHASE SHEET NAME To learn more about Enphase offerings,visit eriphase.com . To learn more about Enphase offerings,visit enphase.com EN PHASE. DATA SHEET ©20,8 Enpna.3e Energy.A.rights reserve,..-.A trademarks or branas asee'are the property of:or:nose Energy.Inc. 2018-05-24 PAGE NUMBER REVISION DS 0 , _ Enphase 1Q, Combiner+ BLUE RAVEN Enohase The Enphase IQ Combiner+ with Enphas€ IQ Envoy' consolidates Interconnection MODEL NUMBER 1220 S.630E STE.430 :IQ CoMbiner+ bil Combiner+X-,IC-AM1-240-2 _ _____ IQ Combiner+with Enphaae IQ Envoy'for integrated revenue grade,PV production mete—iiirding AMERICAN FORK,UT 84003 equipment into a single enclosure and - lANSI C12.20+/-05%)and optional*consumption monitoring i+).-d.5%). 800-377-4480 (X-1Q-AM1-240-2) streamlines PV and storage installations by ACCESSORIES*der separately) WWW.BLUERAVENSOLAR.COM Enottase Mobile Connect' CONFIDENTIAL-THE INFORMATION providing a consistent, pre-wired solution for CELLMODEM-03(413 112-yeaT data plan Plug and play industrial grade cellular MO., 'with data plan for systems aspto 60, . HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF CELLPAODEM-01(3D ii 5-year data plan) microinv re.(Aver:MP-1e in the USM .,Canada,* exicoIs ,Puerto Rico,and the US Virgin lands, ANYONE EXCEPT residential applications. it offers up to four ci-Ei i.ODEM.-M1(4G LTE CAT-M1 i 5-year data pan) •- ire there is adequate cellular service in i -instal)4(n area.) BLUERAVENSOLAR NOR SHALL IT 2-pole input circuits and Eaton BR series Consumption Monitoring CT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE CT-200-SPL IT Split core current transformers enable whoie home consumption metering*(el-2.5%). RECIPIENTS ORGANIZATION, busbar assembly. Circuit Breakers EXCEPT IN CONNEC TION WITH THE ERK-15A-2-24G Breaker,2 pole,15A,Eaton BR215 SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE ERK-20A-2-240 Breaker,2 pole,20A,Ea,i: :1 20 WRITTEN PERMISSION OF ELECTRICAL SPECIFICATIONS BLUERAVENSOLAR LLC. Rating Continuous duty o. . . System voltage 240 VAC 60 142 ›- L1-1 14-7/ "I. Crli Eaton Mk seines bu •.r rating 125 A Smart Max.continuous current rating(output to gridi 65 A 1rs-N- 1- I2L Max.. ,-icircuit rating li , .or 0 . Z c°. , ) 90 A U)iI- Lu 0 • Includes IQ Envoy for communication I- co - . . . . i and control Branch circuits(solar andfcr storage) Upto four 2-pole Eaton BR series Distributed Generation(013)breakers only trot included 1- co Z > 09 . . . ,. 0 0 < ... . , . , ...._. . - ,-.,,.....0.,-1;gro,..A.rw..12r,..•v....a,. it' • Flexible networking supports Wt-FI, Max.continuous current rating(input from PO 64A 0 ,„*„„„„. 0 0 . I 411111111111ista,*i,,,i,.! iiiiiiiili..•i:::4 Ethernet,or cellularWMax.total branch circuit breaker rating(input) SO A(any combination) -) Cr) o D 1 .1 ..,iditt. 5,"'-',i:''.%Ift ':-' • Provides production metering and optional consumption monitoring Product,.:.Met- i v.CT ZOO A solid core pre-inMa i ni and wired tolp Envoy CC _I _ ' f g CL CO MECHANICAL DATA 1 li ii. . ,i,11-1-11r :$4.,d::::1-1 • Supports installation of the ________. ,%3 ''''' enSiOnS(VilyHxD) 40,3-x46.5 x 16.0 cm(10.41.k1.8,31 x 6-3') aii,;.!'11!.;.;1. :.!*..::!:. .41'f4715 !I Enphese 0 Aggregator -,....,:.,,,,]. ..,..A.6, •ciiii: Weight 7.5 kg(16.5 lbs) . lad,iiii.111,.: '11.1oli i''11014niki Ambient temperature range -IV C to+-.1-C(-4011to 115°F) , -,,,,, * Simple Cooling Natural convection,plus heat shield i i. .:cc:,iii,,,,.i, i --':..' --21-7): -' ' • Eaton BR series ponelboard interior Enclosure environmental raring Outdoor, it -certified,NEMA type 3EL i y-. .,i i ate construction — -a ' 01'1:•1.'i 111•111-1.----e.,ii. i-- -. :di. , 'si....-iudidpi.inkkentio Up to four 2-pole branch circuits for 240 VAC Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors ' 1,2:11„,„,„.„,,,..„1-- -,,,. -ni ilinilliol°11111111111 - • hi ::',474 plug-in breakers(not Met i-d) - 60 A breaker branch input: 3 to I/O AWG copper conductors 1111 ii111,1111';'1!litriii „. ..1.11, -'-', :•11,,;.,,.0t,,,st:15 ' Ma'n lug combined output 10 to 2/0 AWS copper conductors • 80 A total PV or storage branch circuits 1' ' . '.I1-1. II:I °chi"- '111101410011i, iii • Neutral and ground: 14 to 1/0 copper conductors - . .... , Always follow local code requirements for conductor sizing. Reliable . . To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS • Durable NRTL-certined NEMA type ________ . ________ Integrated Wi-Fi . 802.11b/gfrt 3R enclosure Ethernet 507)3.Cat5E(or Cat 61 UTP Ethernet cable-not included • Five-year warranty Cellular Optional,CELLMODEM-01(35)or CELLMODEM-03(45)Mot .1..mnludedli • Ili_listed COMPLIANCE CIO ComMiance,Combiner Lit.1741 : . /CSA C22,2 No.1071 47 CFR,Part 15,Class 8,10E5 003 Production metering:ANSI C12,20 accuracy class 0.5(PV production) LISTED ENPHASE Compliance,10 Envoy IA 016 so learn more about Enpha se offerings,visit en. -.com itioni CAN/CSA C22.2 No.61010-1 11 Consumption monitoring is required for Enp hese Storage Systems. To learn more thout Enphase offerings,visit - Al ase.etwn SHEET NAME *,,,ria Pim'''Ele V.Al,lip tt-i*sef vtl..t Ai,fatk-yrom-L:1:$mews in tris dionnent are registered by ThBif .-*.3-t1-...,`..1v.....uwoer, ' .. ENPHASE. DATA SHEET 2018-0502 PAGE NUMBER REVISION DS 0 I , ,..„... BLUE RAVEN „....„ jiiiiii . ...., iliiiii i-Ptl, . _ SunmoduleY Plus .„.... .„.....„ SOLARWORLD iilt, SunmoduleY Plus SOLARWORLD 1220 S.630 E STE.430 ... SWA 285 - 290 MONO BLACK .„....... __ „:„,.,, SWA 285 - 290 MONO BLACK ,......../ AMERICAN FORK,UT 84003 REAL VALUE :iiii•A REAL VALUE 800-377-4480 WWW,BLUERAVENSOLAR.COM PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)* '-- - -,--.ri,,,,,-----, -...„ .... - - -Tiiiiii.i.:.Ato. ,•-:i',?-- . .....,.. 18." „..,- . CONFIDENTIAL-THE INFORMATION ,'.::',.!!•,•,:l:',.,.:::: Data sheet i*cililliti, 4,f..- --i.---' . -.:91 -r SWA 285 SWA 290 HEREIN CONTAINED SHALL NOT BE „._ USED FOR THE BENEFIT OF Maximum power P 285 th/p 290 Wp ANYONE EXCEPT Open cirruit voltage V 392V 39.5V BLUERAVENSOLAR NOR SHALL IT .........„. ,„ __ Maximum power point voltage Vt... 32.0 V 32.2 V BE DISCLOSED IN WHOLE OR IN P,A1:1-,I!'. '''.-..:;'-:','''.•:''''''':.-':':;::•I.fT:10:•:-,lininIIII,i:i.'-',.. 1115..+72-..-- „- „ PART TO OTHERS OUTSIDE .„......... „.„..„.. Short circuit current 19,524 9604 RECIPIENTS ORGANIZATION, ;!.'f;!,:j,$,:,•:.,1.',::.',,,, ::,:•;,:,. .,,.;.,,,A-r.04 --- .„.„,01%--- „„,„0-- Maximum power point current I, 9.004 9.12 A EXCEPT IN CONNED TION WITH THE Module efficiency 4-, 17.0% 173% SALE AND USE OF THE RESPECTIVE Measuring tolerance(P,,,)traceable to TUV Rheinland:+/.2% *STC,1000W/m1,25'C,AM 1.5 EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF ...,.., , , :::„..,..., PERFORMANCE AT 800 W/m2,NOCT,AM 1.5 BLUERAVENSOLAR LLC. . .. . . ... . -,,- %,i':';::. •••::-'.•„ .,:4.1,4610911PW',,E''' . € I I IIIIIIEIIEE;II•IIIIitiE'iIiiair.111-511111111411Iit SWA 285 SWA 290 ..•,•.-i.:g.i.::: :::-.::::',.•:iii-it.727-iiiiiiiiEE, I 1 : • • , . . . co Maximum power P.,„ 214.8 Wp 220.0 Wp WU-1r 0 < • 1- 14.7:U:' '' .! !4',,411,:tirgiilliii , Open circuit voltage V.,„ 36 2 V 36.6 V 0 ryZ 7r H ('''') .71: Maximum power point voltage V 29.5 V 29.9V < 00 0 - 1...... , :i -,p, 1 Short circuit current I„ 780A 7.86 A z P (3) < Cf) IIIIIIII.',IIIII;:!III, III,IgiiIIIHiliiiiiiiiiiii5 • 1 Maximum power point current I,,,. 227 A 7.37A IIIIII1IIIIIIIki„1,•-IIZEit.„Appiliiiiirt,, , 1 ti Minor reduction in efficiency under partial load conditions at 25°C:at 200 W/m1,97%(+/-3%)of the STC efficiency(1000 Wired)is achieved. IC ,t0 .1178 if-- >wz Q 1 , r c ,--,:------, co , ._ . ..._.., .„...„. PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION 0/- 0 0 < 0 C'• iri•-.7,',..,:•,--C--liqi-rdiiiiiiniiiiiiiii:i- - soswi L.LJ (-) Iii•.°' -1-i'•-• litiAliiiiiiiiii; i 1 Power sorting_ _ ,D wp 2+5,itip , • Cpe --ill 1'5014001 411!!!116 :' ' .10...........4.. cemrrea --) Cr) w . . „..„.. .. • . ..,.._ , „.....„.. Maximum system voltage SC 11/NEC NEC 1000 V 0 . - -..... .... ..._ ,„.. .. .... ......„ . . - • -- . .--- . ._„„..„.... .......„ ... ,.,...„„„„..... . Maximum reverse current 25 A 37.8(961) • iitilIstI/1332.tiiii.86, dimwit+, 0- CO Number of bypass diodes 3 4.20 - iso Operating temperature -40 to+135'C (106.65) I 4x...1- . Maximum design loads(Two rail system)' 113 psf downward,64 psf upward 712 I5026(OA QUALITY BY SOLARWORLD Maximum design loads(Three rail system)' 178 psf downward,64 psf upward 08085) 'Pease refer tothe Stinmoduie instahation nstrucl ons for the detaiis associated with these load rased . 25"3 33,1)1 COMPONENT MATERIALS 0 0 SolarWorld's foundation is built on more than 40 years of ongoing innovation,continuous optimization and technology expertise.All orocdoumcteioinCelts per module 60n '. steps from silicon to module are established at our production sites ensuring the highest possible quality for our customers.Ourmodules a variety of different sizes and power,making them suitable for all global applications-from residential solar systems to large-scale power plants. Cell type Monocrystalline PERC a Z1ts 91 so Cell dimensions 6 in x6 in(156mm x 156 mm) cs Front Tempered safety glass with ARC(EN 12150) m ,i • m Back Multi-layer polymer backsheet,black Frame Black anodized aluminum ,A1111 iZ Elegant aesthetic design-entirely black solar module,fscm-r) ))))) SolarWorld Efficell'PERC cell technology for the highest 1 ill t-Box iP65 the cells and frame to the module corners possible energy yields Connector PV wire(111.4703)with Amphenol UTX connectors Extremely tough and stable,despite its light weight-able LZ Patented corner design with integrated drainage for Module fire performance (U11703)Type 1 ,3),0) 4111.11111"1111 7 to handle loads up to 178 psf(8,5 kNI/m2) optimized self-cleaning ___ ..„,___ _ AMIIIIIIIILIIII al Tested in extreme weather conditions-hail-impact tested CI High-transmissive glass with anti-reflective coating DIMENSIONS/WEIGHT THERMAL CHARACTERISTICS 1132 I ,inNIIII II and resistant to salt spray,frost,ammonia,dust and sand '`iiTi: Long-term safety and guaranteed top performance- (287.501 I 0entnuNOCT 46`13 Proven guarantee against hotspots and RLgh 65.95 in(1673 n) D-free to 25-year linear performance warranty,20-year product Width 39A0 in(1001 mm) TCIe 0.07%/C -- -- IEC 62804-1 warranty39 4 OM) -- 11 Height 1.30 in(33 mm) WV,. -0.29%/C 1.30(33) Weight 39.7 lb(18.0 kg) TC F.... -039%it All units provided are imperial.Si units provided M parentheses. ORDERING INFORMATION CERTIFICATES AND WARRANTIES Order number Description IEC 61130 1E6 61215 lit 1703 Certificates a 82000248 Sunmodule Plus SWA 285 mono black 1EC 62716 ICC 60068-2-68 IEC 61701 a, ,.....:•:*:.:.: 82000260 Sunmodule Plus SWA 290 mono black Product Warranty 20 years 6. . t m Warranties' linear Performance Guarantee 25 years g ,... MADE IN USA "Supplemental warranty coverage available through SolarWorld Assurance- li4. OF use IMPOATED POTS Warranty Protection Program-wwwsoiorworkicom/assurance wwwsolarworld-usacom SolarWorld Americas Inc.reserves the right to make specification changes without notice.This data sheet complies with the requirements of EN 50380. SHEET NAME DATA SHEET PAGE NUMBER REVISION DS 0 ECHXECR IN BLUEcooRNTNHEE „,,,_ *......„ a S .... .„... ck ... . .:,_, , ,,,, „ , ' -,,,t,-.44 if 1.,,,.e.,w . 1 2 2 0 S.6 3 0 ERICAN FORK,UT 0 NAEUEFINAPSIIEXCEPT D RE sAT EV.48E34 00 0N3 WWW. 800-377-4480 ,,do ra.,-•;_,,..,,,,i,.,,,,,,-.:::.1..::,.,,z,,,,,,,,,..,,!a,,c,,i FLASHED PV ROOF-MOUNT COMOINER/ENCLOSURE _...,„,,, • i‘,....*„.„44.6 Basic Features -tiftifirola4.7.1 7itiltpt;iiiiitz,r.tiiv .s.., NOR SHALL IT Stamped Seamless Construction_eel :::5-i*.q,A...„...:-..H„.„4,,,,,,,,, ,,w1;,,,, 1 ,7-rt. WHOLE 0 R I N • 18 Gauge Galvanized St 7,,,,, ,..3.,.„0„..„410„ . PART ORGANIZATION. • Powder Coated RECIPIENTS Surfaces 'kit...A,- _._iii,,,, ,,,-, • Flashes into the roof deckn n INEXCEPT B L U WRITTENE RAEBCONTAINEDNLETUNI EASRLOPA-ELVTAREHNEBSISE°SNLSHALLIEiAFTNRI L Ti_.INFORMATIONCo°FiT1\11 B BE B E DISCLOSED ANYONE • 3 Roof deck knockouts .5 , .P.INF'71- - --_,,,,,,,d4.4,-4',-„,4q11- .. . . ..., . „. _ - - .....,„ • 5 Centering dimples for entry/exit151 . . BLupETUROsAEOTE HNF OTHERSOUTSIDEARNWITH THE fittings or conduit SALEANDN 7 1_ Lt. _i nt7tc,C To VE • 2 Position Ground lug installedEQUIPMENT,WCITTrIOORI:PE Z I- F— 0 ' 0 ct 00 0 w r•-- • Mounting Hardware Included < D cy) < ch,s SolaDeck Model SD 0783 Z 71- c: Z • 0 ..._ ... < Lc; }-- w 8 2 1-- co z > 00 H 8 cr) 0 < s°1AavDaileabclekrouodLe5:_(3"1. 3R Enclosures w u.) Li Model SD 0783 —) 0 _J Model SD 0786-(6"slotted Din Rail) CY yfipxeed Din Rail) ca .k.:'''',,T,:: -....A.'•-.' - . -7, a_ ::-,'„.,;:::::•:.,, 'Ilik Models SD 0783-41 an SolaDeck UL 1741d Combiner/EnclosuresSDo786-41are . Eri_ labeled and listed UL STD 1741 --- 1,ctiaPiir ,-- - - accordingRatetdo_th6e0UovL DSc7112704A1mfopr:hotovoltaic combiner enclosures Max ftigliat 011,--- c:,- Model SD 078 **Typical System Configuration 3" Fixed Din Rail fastened using Norlock System Fuse Holders 600VDC 30 AMP vilim-....,:,- '7,:-• MP 41--DinPower RRail i i MountedDistribution i iiiiiiiiY--", lug ugBlock 600VDC 175A Bussp()B7a8r6-iiwith 1U6,1: Modle-1 Slotted DinRail fastened using steel studs **Typical System Configuration Din4- RailRail Mountedmounted TFeursmeinHaoildBelorsck6s00VDC 30 AMP 4-Din Bus Bars with UL lug - gif441 - 6: kintkr r —Fuse holders and terminal blocks ....,..... „. ---i.• ...• added in the fideld must be UL listedAomrp meet 600 VDC 30 r1e1w0Cgnfolzrefdusaenholders,600V 50 AMP ......M ........ ' .. ,„„,,... 90C for rail mountedtermfidnrapl blocksower an . and 600 V 175 AMP 90C ,. •. Distribution Blocks. Use Copper Wire . Conductors. . cdConvdeuritiadtrrifmitridegdsLtobaaslelowis Mai Modela SI Dm00u7pd8ot3ew-4de1fr d,distributions fuse i r wiredd l dweitrhs, bus bar andtDMeiormndRei nal aSill Dbmiod0c7dk8dst6e-ad4n1fd,d swteui rsehdobladwresitrh.s, • block. celdcantteidrddsimpled for fitting PAGE NAMES0 RS TC Enterprises, Inc • 2219 Heimstead Road86 ; -7 6•3E6a7uC7Ii8a2re, WI 54703 AGDENALJEAR REVISION SHEET For product information call 1(866) . BLUE RAVENor . F SYSTEM BONDING & GROUNDING ! T1220S 630E STE430 AMER':F: UT84003 TA _ T N r 1 WWW BLUERAVENSOLAR COM , **''''''.-I---------------------------------------•*--------------- CONFIDENTIAL-THE INFORMATION Imilirlill j mutt a616-- ---1--_-„--j- uni'-----L-T ' lr--- , HEREIN CONTAINED SHALL NOT BE C-- USED FOR THE BENEFIT OF lar , _ c> ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT 1111 BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MEI RECIPIENTS ORGANIZATION EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE , ,.. • , -- ,--.: ., , . I as EOWB RUL LI TPETMRE PERMISSIONEANNyTENWsI oT LHAORUTLLTCOH OF MN ILI U-I 1" 0 < j- ammi ,, ' H Mil cc ' 0 0 • < 09 is- . z D (3) < I) l'. ,:.,- al ,-;:..---------------_ __,_--,..-7-t.z..------._____,.___=,__-_____ ___----------_ 24., < 0 '7t CLZ ('`) OW ' :i:- .-.-, ..,:--- - -f •::' ''.'• MIN E-W BONDING PATH:E-W module to module bonding 2 H 6 1--- in O NIL . is E_ co •\_,.400. - accomplished with 2 pre-installed bonding clips H 0 cr) 0 < c° minc) in which engage on the secure side of the MicrorailTM in 0 MVP1 D and splice. 0 cc _i NUN MN a_ Do am umemicummiuci.a.m....rmH.,iammmni.rmo.thm.r.arciciliiArcw.aarmmi.eisrairrmm.rarmii.TcmmN.cmmamm „w 11111111111 IIIIIIIMIIIIIINIIMIMIIIIINIIIIIIIIMIIIIIIIIIIIIIIIIIIIIIIIIMI NM 11111111111111.1111111111111.111111111111111111111111111111111111111111110= Star Washer is WEEBLUS 4, Single Use Only Single Use Only TERMINAL TORQUE, ... . I Install Conductor and torque to the following: TERMINAL TORQU6, TERMINAL TORQUE, 4-6 AWG35in : i-lbs Install Conductor and Install Conductor and Ci.. 8 AWG: 25 indtis torque to the following: torque to the following: <in 1044 AWG: 20 indins 4-14 AWG: 35in4bs 6-14 AVG: 7ftilbs N-S BONDING PATH: N-S system bonding is LUG DETAIL & TOROUE INFO LUG DETAIL & TORQUE INFO LUG DE IL & TORQUE INFO accomplished through a N-S bonding clip.Insert each Itsco Lay-In Lug (GBL-4DBT) Ilsco Flange Lug(SGB-4) Wiley WEEBLug (6.7) end of the N-S bonding clip onto a module frame • 10-32 mounting hardware • 1/4" mounting hardware • 1/4" mounting hardware flange. Systemgiti y ley edge, • Torque = 5 ft-lb • Torque = 75 in-lb • Torque = 10 ft-Lb dowever it is recommended that N-S bonding clips - • AWG 4-14-Solid or Stranded • AWG 4-14-Solid or Stranded • AWG 6-14-Solid or Stranded 5e installed on both edges for ease of maintenance NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION enc. aten- Md;inTnr nnod Paon s'i System bonding is accomplished through modules. System grounding accomplished by attaching a ground Lug to any module SHEET NAME DATA SHEET at a Location on the module specified by the module manufacturer. PAGE NUMBER REVISION DS 0 Intertek. AUTHORIZATION TO MARK BLUE AVE' - This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) ' 1220 S.630 E STE.430 Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing AMERICAN FORK,UT 84003 Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing j 800-377-4480 Report. WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be HEREIN CONTAINED SHALL NOT BE applied only at the location of the Party Authorized To Apply Mark. USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Applicant: Unirac, Inc Manufacturer: Jiaxing Pacific Energy Equipment Corp. PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE No. 8 Haiwan Ave SALE AND USE OF THE RESPECTIVE 1411 Broadway Blvd NE Hangzhou Bay Bdao New Area EQUIPMENT WITHOUT THE Address: Address: WRITTEN PERMISSION OF Albuquerque, NM 87102 Haiyan Economic Development Area BLUERAVENSOLAR LLC. Jiaxing City, Zhejiang Province Country: USA Country: China W W d L Q c) Klaus Nicolaedis Lili Zeng Z 't J Contact: Contact: Q CC oo U O Jason Mayfield George Huang ~ 505-462-2190 510-979-1920 Z o c5) Q z r Phone: Phone: < O 7t. CC Z m 505-400-2949 650-799-7627 6 1— W o FAX: NA FAX: NA U OcY) O Q co klaus.nicolaedis@unirac.com Izeng@ccmfg'com LU U U Email: Email: jasonm@unirac.com george@ccmfg.com 0 W 0 D Et J Party Authorized To Apply Mark: Same as Manufacturer IL CO Report Issuing Office: Lake Forest, CA Control Number: 5003278 Authorized by: „' for Dean Davidson, Certification Manager GUS trs,eo Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to M ark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to M ark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first he approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s); UL 2703 Issued: 2015/01/28 Ed: 1 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels Photovoltaic Mounting System, Sun Frame Micro Rail- Installed Using Unirac Installation Manual, Rev • Product: PUB2017FEB16 Brand Name: Unirac Models: Unirac SFM SHEET NAME DATA SHEET ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued: 2-Mar-2017 PAGE NUMBER REVISION ED 16.315(1-.Jul-15)Mandatory DS 0 UNFRAHE MICRORAIL ne S : . y,, - , , s R I ------ ------_----------A ---- ..1.6 SLINFRAMPAIC -frt. HAI tii'LG aiNSTALLATION GUIDE -__---_----------_---------_.....,._ TO,,,.._0:,,..1.S & ASSEMTEBel.,Y ,,,,,D.:_!!,,ar,1A,11,..._f7E: 1:7AG,.: ... .., 1220 S.630 E AMERICAN FORK,UT BLUE RAVEN sTE,4084003 1-1-1111— RAISED SEAL FLRAaS . .... „. . .... A,A.wozoiEstAtw- EKTPAI.,q;rxtfhtrakAiPxrtk'I4sSAA,,,,.,A.E,AA*:AA,,:.. is RAISED SEAL ,,,,, 800-377-4480 s.---- .,,f.....„--..,,,,,,,,,,,,,„„.T.:,,ria,„"m241:t42---AVR:..`"',t. "*.•;i''-- ,L .4aL.:*rP'bV..afttila%:sy4;A.s:XA14.ta2.tkb,.i't:LYtf*LtfXrEiAV*,rt'.t/ST'Y':.sV,e,:'Ys IVOilt1-40:. --. ..1 ATO0c.iyAHAOPLSE:MTRLE&AIENS:u.INURSTIEREADLLAOTRIORENC:OMMENDED FOR ,.._ . :'-",?Istablir;ZAV44YZW:M7-1,; ,;,0-„iiii-Rli-0:',iT'""".' ''' ''."STLNYLiStstirAw.ssa.17:s.:14sLA:A.,.vainierAri-,ls:rjt'N-tierMOR:;"':, •ROOFING CRAYON .;;;;;.--t.,,,,,,, - „‘",,,,„„,. • ;"'-`t,,,,i--;"'";-"Y'elga:IRV. r,"6'T.' lail.T:;7:."!!'t-1:..,-:li::' .HAMMER il,`:'''':Z,,-'''''..:',: '''..f;131''4',:.4'''''0';.....•A40i,V.4".1.:';'. , • 7 .-„,., '-'---.,„, ,, , .•CDORIMLRLAITNIIRTLHEESrErAHLEARNITI8A.NBOaD,z7GNSRKERAND ,Ia..' . , .,,,,,,,,,,-. ,,,,,:„ _.„,,, ,,,::,,,,, 70: - --e---5'- i',;:::;-"-.Nr;:C;ST'.•!-:t7i4iiVi';X:i•- .. • iciiftt:,,, .r- •4:3:.-44:,,44,:Sii.','t --->„'---,---- , ,,,,,, ,,,,,, 01, ,,,,i , ,.. , , „ . .,,,,, „ cHB,EWB:NEuWuEFED:11,NDIEsA.E:ccvNAEFETNIONN:ASTR:LEA0ANT:IN;AIEEEHNERDNEXBINsCEI:HOHNEOLFAREPAOLLTFSRELRI T.HCMNOAO:ARI SHALL _INI BT EN '-i-;,44,:' • . di 'A'474:4"14.NitiCesin's. '•?;k:-lts:.,:; .0tt'ofqrTft,d*V .4'W"'A''.'i; 7-,_-_---'---, , •,, . --,40--- , '441%,,---,%,- ,,,- ,- .--0, -'4,-,,' • • , • . : , ''':it-':',.:',"-;','-':'-'?1,- .' ' ', ':-''''-.0AitiirrIP •••-'.4#4:-. .4•,•,.`,.4e,*•,..44:**:,,V.,:i!•K•1441A14't't F!......;: ;-ti'''; - .' ;. '. '::*`..14N5,1124tOkti,,:'`n•4P4.•, -VSQ1 NI 6"i'" ,... ,... , „ '114A' i'il 's•:*' ' ". * -...... F?:lit',..::Y ' ' '''.“. '.:',.- ' ' ' ':',i.'.-r4.,. ;Pt:''!';;,v,;'MOJAlti:,::::.*:• ,,,,.,., *11.lij. 1.t= ,iltct4.4'• -r- fr 1 f,,,&..,- • .0.••.4 .1 SFM RAISED SEAL FLASHING COMPONENTS: -,,,,,,,,,, '.- BLUERAVENSOLAR LLC. s:c'HEX8.1UITMRNFER DRIVER LACGUDRIVERSTFBOLT O1)W INS TTI R AHR I j 1/2;T"CUSTOM SOCKETURASCSTRUCTURAL(ROEPWT1°°RI4A71:W ... , ,., 'gi'.lielliiiii:' ' ' sE Ax LCREEEPWEQAPACTRN:IN I WRITTEN TTEumcEONsEoNTENNST0NO,OTHERSFEWRTIGTHTAHEI NOOORI PERMISSION NuzUEATTs\NTSpTI:1 THEODFHcENE T1 THE 1 v E L FASTENER: ...--:" ,...,,,,,. ....,, ...,- 7'''' ''''''-'` -..,-- • • >"' 1-- 09 ,,,,..:. '' .,,,,-',!:0-gir,R:s.,:.':. :3:, ::,:Atitek,t,:,:t4,,A4z;:v.fi'veriAi •-..t.. 0.4:1:-.:;Altoeig 4.4... ..A. :towsLAV .LAG DOLT S/16 ''''1' .'"."1:'''';''YVIVtiYik".se:- 'sra''''ely., ....1'`.r'-"d14".%;r'-:'.4r$4trit':*t„ZailtiX144e:r•l'"iist-, AZ-,W4N2a;-:20"1,"V:.:ZiVi „„fi:0*W" ' r: Q < - ,- Q.I'dirs le...itilt4:-.4"A.:,l -,‘2a:::!-T,I.EW'tia-L,tt-i'...1"?0;ktre•t&4'SytiVhatts:lia',15.iisis,L4:*,C14tri '..A,:::',,,itt4,2*1.. ....kqvxl-,,,,t, 1 UJ j 1-1-1 •1- 0 ' ' :i-'igr)***4" -i•Ai.-.:,'4'4.00.V-Z40;:--74:‘,...V.04.1*Av.?.,g;r4ittist:*.'4',14,1!:,All4e.:(:Pt&W:':60.741t04-0.4 Z •:r H 0 7I-. 0 . : .. -Ate.,4*-....,:-,,',:--,-,..4.1:4,0;00*......„tkei.-4,av;.k0swilkAY•iitttt- ',viiv...1 Attko,- A"*:''''*4"-' ' -.00.- : < co 0 (,) r _ D CY) < 42,•s5 i IFGu mRN61(..1 RAISED I?AI STRUCTURAL D cE cDupsrms OsMEL STRUCTURALAFisIocSGRHEwANGSSlin WASHER .R SCREW,S i I-6* Z 'i- CY) 0 z ' PG < TABLE OF CONTENTS: Lo 1— in cp i l',,,A;:oiSitTdisAsnhLuilAngt nTleelcOreosNosfN,ywOoiTthrEsSto 5_518.courses. 2 H co z > c' Tools&Assembly Details 2 Quick Steps for Installation 51.COMPSNMSOHUI NNTG LAESSRE:08FLy VARIOUS(WITH SLIDER CB,TheMountsS FMshouldRaised riot Sealbeinstalled Flashingadvisable i st°i nmuas.etila meant:siotwsf oother lt'otherw,oi withstandardfssataustsricedenapertirdsbaltoen dtlech definitioniicguereh-dtahme ir,g,.perimeter ondoiPonding gthewa 01-- 8 cY) o < ° o composition/asphaltnIgand w 0 —) CO LU naterscan travel D 0 _1 underupward shingles and reach the bolt penetration: C.. CO D.Fastener length specification and capacity verification are the responsibility of the installer. a. PUB2017JAN11 1,11 PA GE .6 - QUICK INSTALLAITNsTIOALNLATSi6TNEGdpiDS1 :Li: RAISED N'‘•;: ..,`-'.::.`--'-r ' .- :..'t;'" ,• •., , :,`,..-,,,j,,;;!:74-,,3,-,,,7-1-",':''','":~:-::::7,:i*e'll .. - . '*.:07:4!::',:.• .. '` 40;f::. .,. - ..,,,-;,,ii-c:,;•711 :-..,,,...- 0SEAIM. ICII°S.AIIIIG„ ,,.. .•:117';':','''''''' '''''''!4'fq•1;,-f, ••• •- ..-4.flAilitill.of • ,,,-:.:*•••••, ''''''':A''• • V H '•'r•H': :','-••••T- :' •Arit•MigiiiiiiRW •'','I''....:.'' :41ggliigrer;•,,,,j1,,505..f7:•:,•":; ".*•%**1,•..,,,,,',..t411144*---.,k4:, .. . ,ri!"..1. .i- ,•-;, , . ,,e. . 0:1.1 ,,,,,',!T,,,,iigi,,,,,,--, ., --i ,N,-?c,...,.,:1,,L..,,,-.,.I r.1.., '''. ,:- '• ,.. ''' .:, ' . .,. .afigIV*.,.*;, '4:ii.4.1tAat;ii;"t , i '2 4sP, .....-.-'." . .'-- '•'-.•- ...` '..:.•..,..,.• . ' ''-'s,...W." ; •:- S . i:j.IcY0,14.irkiAl' ::::‘1,.; '''.'''':.31''''C'''''''$`.••:-Y''..'.?.....'.;-:,t,'. ' '... ... . • •-. .-'' - ,---.-- '. '...1:t'... .ik,,*.:tfr2•,!,..?..,:.:-".04.1.4. -,..',i':','i-''..''.."."'.;.'"''';:',7-41'.'ff.'.....•E'„. .- '.. • -..•.' ' ‘ l' . "‘ : ' , ,iE' drill hole w ith OPTIONAL SEALANT, . •_ O-N,, '•- ...FLASHING:'- hartobreakse:ls6e;weer1:tasgaetottierafteidrilt:::deeppo! apropnateseaantApplydcircleshapedbea, oh :ldrn 2idind2idald3rdsh:ngte,: rs. leiintoceteoitafteusing , droundtheattachmentha,darhole 8, r0reli,e1ln:ilst0ttiaicftextesionbitlfo:5Il6:0Koft,erashingbeforein,erti: oo or l, rwornotuseexcessvesealant. extensionnrstallation guide fur propeif1 ,hg7I2:airraft ,tfor5l6, placement. lag. - -..">",Y.•.*;-,tiiv',44,4,'''.:::Z ,4T.! 'n ''''''' r::::::' $,Y.Z: '.::.,;.,:::fv:'-',:;., ';',:itt.,,4. ..:11 4::::'V%.. , '4551444%; ..2:f]..'::'.7.1.`''l.:'''';::417;7;:''''.*STAN::: - •'''';4:;.''''''''''.:'''';''''''.';'', :''''':...''''. ..°";:;'''""..*:- '4,'.• ''..,*.eVf'hth'Y.,F. '. '. '..''''''.:'%•."'''''t Vidik, '' . 4:.,'' ,''.%;,', ,''''SY t''''''.;., ,,,,,,,..,,,‘ .4" aitVit:t.:Z It iiN '. •:.,.''..':..::'t!'j''1..4:'•W';:::'"WA :'' .' '''''.:':''S'' '::'''''..'' .".*r' ‘St :tS:T; FLASHING: Slide :: PLACE SLIDER: P'-1a:es :li derU:hI NS: A LFASTENER & T G:T E: COMPLETE FLASHING INSTALLATION: ttashi1IUIinththe2nd;urslasseblvetthefashin; t:. ottl:fasten:rithseating1washeRepeatprevious steps to install all of shingles,so httleblttoiredge,singtistid: litiaont;eS:Ilthelioertogauge ,op : inoits. of fthe flashing does not overhang the flashing torgewhendivingtheasteneFi SHEET NAME edge of the 1st course of Tighten until slider stops swiveling shingles. easily DAT A SEIEET PAGE NUMBER REVISION DS 0