Permit (181) CITY OF TIGARD MASTER PERMIT
s ' COMMUNITY DEVELOPMENT
Permit#: MST2018-00239
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 09/24/2018
T t r..1 It.D9 Parcel: 2S104AC07800
Jurisdiction: Tigard
Site address: 12734 SW MORNING HILL CT
Subdivision: MORNING HILL NO.9 Lot: 221
Project: HEDGECOCK
Project Description: Solar photovoltaic system.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $11,081.71 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0
Drains: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Other Fixtures: 0
Drywell-Trench Drain: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add'l 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Other: Y Other Description: Roof Top Solar PV 4.35 kW Ecompasing: N
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
ALT SF VB R-3 0
Owner: Contractor:
HEDGECOCK,PETER&CYNTHIA BLUE RAVEN SOLAR LLC Required Items and Reports(Conditions)
12734 SW MORNING HILL CT 1220 S 630 EAST,STE 430
TIGARD,OR 97223 AMERICAN FORK,UT 84003
PHONE: PHONE: 385-498-4408
FAX:
Total Fees: $412.38
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other .- . All . will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if �j•�—ed f :�e 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Ce •, s--- - forth in OAR
952-001-0010 through OAR 952- -0090. You may obt-; •copy of the rules or dire questions to OUNC by calling 503.2 : 09-;:Iel. -1yJJ--+t"�/
Issued By:
-ermittee Signature:
r--
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Building Permit Application.
pA
Residential E EIV
FOR OFFICE USE ONLY
. City of Tigard AUG 2 7 2018 Received _ t'
/ Permi -7-1 �. /
DateB 7 ` / if, �T`t/! UG
III
® 13125 SW Hall Blvd.,Tigard,OR 9 3 y
Plan Review
Phone: 503.718.2439 Fax: 503.594416Y OF TiGmf Date/By: Z tO a A/4-- Other Permit:
Inspection Line: 503.639.4175 Juns: ® See Page 2 forTIGARD G1ll/ts it\, ii,„S www.tigard-or.gov ) cdMethod:7
Supplemental Information
TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING
❑New construction 0 Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
0 Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the
CATEGORY`OF �STRUCTION work indicated on this application.
Valuation: $
nl' Q 1-and 2-family dwelling 0 Commercial/industrial 11,081.71
❑Accessory building 0 Multi-family Number of bedrooms:
❑Master builder 0 Other: Number of bathrooms:
'MI SITE INFORMATION AND LOCATION Total number of floors:
Job site address: 12/34 Soutnwest Morning Hill Court, I igard,Oregon, New dwelling area: square feet
97721, United Statag
—
City/State/ZIP: Garage/carport area: square feet
Suite/bldg./apt.no.: Project name: Peter Hedgecock Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
F.,REQUIRED DATA;COCIAL-USE CHECKLIST
Subdivision: 1 Lot no.: Permit fees*are based on the value of the work performed.
Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION Of WORK
work indicated on this application. ,
Rooftop solar PV Valuation: $
Existing building area: square feet
New building area: square feet
*ROPE OWlR Number of stories:
Name: Peter Hedgecock Type of construction:
Address: 12/34 Southwest Morning Hill Uourt, 1 igard,Oregon,
9722', United States Occupancy groups:
City/State/ZIP: Existing:
Phone:( ) Fax:( )
l APPLICANT` PE T • � *N S
Business name: Blue Raven Solar ,' r ' - t ,
Structural plan review fee(or deposit):
Contact name: Tara Mount
Address:
1220 S 630 E STE 430 FLS plan review fee(if applicable):
City/State/ZIP:
American Fork,UT 84003 Total fees due upon application:
Phone:(385) 482-0045 Fax: :( )
Amount received:
E-mail: permitting.department@blueravensolar.com ',,,-',... 'YROE0YOLTAXC SOLARP YSTE `
` CO,s,"....,"
Commercial and residential prescriptivetive installation of
t r , �CT°,«
roof-top mounted Photovoltaic Solar Panel System.
Business name: Blue Raven Solar Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address: 1220 S 630 E Solar Installation Specialty Code checklist.
City/State/ZIP: American Fork,UT,84003 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:(385-482-0045 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lic.: #210112
Total fee due upon application: $201.60
Authorized signature: aiff .c4. This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name: Jeffery Lee Date: 08/23/2018 *Fee methodology set by Tri-County Building Industry
Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
Electrical',Permit ApplicationRECEIVED FOR OFFICE USE ONLY
City of - AUG 2 7 2018 Received
Permit#:
Date/B :
,71 �
' 13125 SW Hall Blvd.,Tigard,OR
1111 503.718.2439 Fax: 503.519801GI•TIGARD Plan Review
Date/B : Related Permit#:
TIGARD Inspection Line: 503.639.4175 BUILDING DIVISION Ready Date/By: Juris: ® See Page 2 for
Internet: www.tigard-or.gov Notified/Method: Supplemental Information
T 4F WORK PLAID"7R VIEW
❑New construction ❑■ Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked):
0 Service or feeder 400 amps or more 0 Building over three stories.
0 Demolition 0 Other: where the available fault current
0 Marinas and boatyards.
CATEO.ORY'OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings.
El 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural
amps for all other installations. buildings.
❑Multi-family 0 Master builder 0 Other:
0 Fire pump. 0 Installation of 150 KVA or
JOS SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived
Job#: Job site address: 12734 Southwest Morning Hill Court, ❑Addition of new motor load of system.
Tigard, Oregon,97223, United States 100HP or more. ❑
0 Six or more residential units. occupancy.
City/State/ZIP: 0 Recreational vehicle parks.
❑Health-care facilities.
Suite/bldg./apt.#: Project name: Peter Hedgecock 0 Hazardous locations. 0 Supply voltage for more than
❑Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site:
Description I Qty. I Each I Total 1,%
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#: Ea.add'1500 sq.ft.or portion 33.92 1
TIO. OFWORK Limited energy,residential
(with above s ft.) 75.00 2
Rooftop solar PV q
Limited energy,multi-family 75.00 2
residential(with above sq.ft.)
Renewable Energy 0 See Page 2
10 PROPERTY OWN" 1 C ' N*NT, , - Services or feeders installation,alteration,and/or relocation
Name: Peter Hedgecock 200 amps or less 100.70 2
Address: 12734 Southwest Morning Hill Court,Tigard,Oregon,97223, 201 amps to 400 amps 133.56 2
United States 401 amps to 600 amps 200.34 2
City/State/ZIP: 601 amps to 1,000 amps 301.04 2
Phone:( ) Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email:
relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
APPLICANT! t - m NT 1� Branch circuits—new,alteration,or extension,per panel
t - A.Fee for branch circuits with
Business name: Blue Raven Solar above service or feeder fee,
7.42 2
each branch circuit
Contact name: Jessica Jin B.Fee for branch circuits without
Address:
1220 S 630 E STE 430 service or feeder fee,first 56.18 2
branch circuit
City/State/ZIP: American Fork,UT,84003 Each add'l branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:(385 ) 482-0045 Fax: :( ) Each manufactured or modular 67.84 2
ermittin de artmentblueravensolar.com dwelling,service and/or feeder
Email: pg.department@blueravensolar.com
P @
Reconnect only 67.84 2
R T .... , Pump or irrigation circle 67.84 2
Business name: Blue Raven Solar Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy
Address: 1220 S 630 E STE 430 panel,alteration,or extension. 0 See Page 2 2
City/State/ZIP: American Fork,UT.84003 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Phone:( 385)482-0045 Fax:
( ) Investigation(1 hr min) 90.00/hr
Email: Permitting.department@blueravensolar.com Industrial plant(1 hr min) 78.18/hr
Inspections for which no fee is
CCB Lie.: 210112 Electrical Lic.: C1214 Suprv.Lic.: 6097S specifically listed(7 hr min) 90.00/hr
Suprv.Electrician signature,required: ,-, " 'rtf '
Subtotal:
Print name: Sam Collier Date:08/23/2018 0 Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee):
Authorized signature: ' TOTAL PERMIT FEE:
Print name: Ben Wade Date:08/23/2018
This permit application expires if a permit is not obtained within 180
days after it has been accepted as complete.
* Number of inspections allowed per permit.
1:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB
Elecfr(i"cal Permit Application—City of Tigard
Page 2—,Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
.RESIDENTIAL OR ONLY:
, ..
,.. ...` Description J Qty. I Each Total *
Fee for all residential systems combined: $75.00 Renewable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva 1 133.56 2
n Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
Garage Door Opener*
>100 kva(fee in accordance
with OAR 918-309-0040) 552.26 2
n Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System*
Each additional kva over 25 7.42 3
❑ V• acuum Systems* >100 kva-no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifical.l.y listed(V hr min)
�
*E �iar ?COMMERCIAL W(/RKONLY:
$75.00 Subtotal(Enter on Page 1):
Fee for each commercial system: * Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
Ti Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ D• ata Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
Ti Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
n O• utdoor Landscape Lighting*
Ti Protective Signaling
❑ Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I:\Building\Permits\ELC_PermitApp_ELR ERE.doc Rev 06/17/2015
City of Tigard st Aug zoos
TY OF
Building Division
��i�.�l �,�
• 13125 SW Hall Blvd, Tigard, OR 97223
Phone: 503.718.2439 Fax: 503.598.1960
TI G A R D Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 12734 Southwest Morning Hill Court, Tigard, Oregon,
97223. United States
City: Zip:
Owner's Name: Peter Hedgecock Date: 08/23/2018
Contractor's Name: Blue Raven Solar CCB #: 210112
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation El Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? 0 No OSSC or ORSC for
design requirements.
Wind Exposure
Is the wind exposure 0 Yes If"Yes", qualifies for
"C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes ❑� Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
above
0 Yes the prescriptive path.
❑ No
1
I:/Building/Forms/PhotoVoltaic-Checklist docx
•
Is the construction
material wood and does n Yes
Type of If"Yes", qualifies for
the construction qualify
Construction as "conventional light ❑ No the prescriptive path.
frame" construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. n Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. If"Yes", qualifies for
0 Yes the prescriptive path.
❑ No
Is the combined weight 0 Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance ❑■ Yes
with Section 305.4(3) of If"Yes", qualifies for
the 2010 Oregon Solar ❑ No the prescriptive path.
Code?
n Metal
Single layer If roofing material is
RoofingCheck the type of ❑ ofwood d
Ypone of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
I-1 of composition
shingle.
Is the roof mounted 0 Yes
Connections of solar assembly
the solar assembly connected to roof If"Yes", qualifies for
❑ No the prescriptive path.
to the roof framing or blocking
directly?
2
I:/Building/Forms/Photo Voltaic-Checklist.docx
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
❑ If"Yes", qualifies for
Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directlyto inches inches, qualifies for the
Maximum 60 inches prescriptive path.
standing seam
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of ❑ Yes If"Yes", qualifies for
fastener? the prescriptive path.
❑ No
Is the roof decking of
WSP min. '/2"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof • Yes the prescriptive path.
surface. ❑ No
3
I_•/Building/Forms/Photo Voltaic-Checklist.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer:Solar World
Model Number: SWA 285-290
Listing Agency:CSA
4
I:/Bui lding/Forms/Photo V oltaic-Checklist.docx
FOR OFFICE USE ONLY—SITE ADDRESS:
This form is recognized by most building departments in the Tri-County area for transmitting information.
Please complete this form when submitting information for plan review responses and revisions.
This form and the information it provides helps the review process and response to your project.
City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT
1 " Transmittal Letter
1 ; ,,\i. r) 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov
TO: DATE RIC
CitT Ei)
DEPT: BUILDING DIVISION
SEP 11 2018
FROM: Ashleigh Egbert
CITY OF TIGARD
COMPANY: Blue Raven Solar BUILDING DIVISION c�;.
PHONE: 385-482-0045 By: c !N
RE: 12734 Southwest Morning Hill Court,Tigard, OR 97223 /VSr..2p/e—'57'239
• (Site Address) (Permit Number)
Peter Hedgecock
(Project name or subdivision name and lot number)
ATTACHED ARE THE FOLLOWING ITEMS:
Copies: Description: Copies: Descriptions
Additional set(s)of plans. x Revisions:
Cross section(s) and details. Wall bracing and/or lateral analysis.
Floor/roof framing. Basement and retaining walls.
Beam calculations. Engineer's calculations.
Other(explain):
REMARKS: Layout of solar panels was changed. Plans have been updated to show new layout.
FO CE USE ONLY
Routed to Pe ' Tech Date: 9 (l (� Initials: /41-
Fees Due: i� ❑No Fee Descripti n: Amount Due:
$ �,,
FL- )\.cin f gAr� $ "IS-
1 $
$
Special
Instructions:
Reprint Permit(per PE): ❑ Yes L No ❑Done
Applicant Notified: r- Date: T/lg lao Initials���
I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012
FOR OFFICE USE ONLY-SITE ADDRESS:
This form is recognized by most building departments in the Tri-County area for transmitting information.
Please complete this form when submitting information for plan review responses and revisions.
This form and the information it provides helps the review process and response to your project.
City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT
IN Transmittal Letter
T I Cl A R D 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov
TO: 4/4 Ji DATE RECEIVED:
DEPT: BUILDfNG DIVISION RECEIVED
SEP Z 0 2018i(i
FROM: Cit r" CITY OF "( ARD
COMPANY: Blue , aven Solar
BUILDING DIVISION
PHONE: 385-482-0045 By:5
RE• 12734 Southwest Morning Hill Court,Tigard,Oregon,97223,United MST2018-00239
(§I4eAddress) (Permit Number)
Peter Hedgecock
(Project name or subdivision name and lot number)
ATTACHED ARE THE FOLLOWING ITEMS:
Copies: Description: Copies: Description:
Additional set(s) of plans. x Revisions:
Cross section(s) and details. Wall bracing and/or lateral analysis.
Floor/roof framing. Basement and retaining walls.
Beam calculations. Engineer's calculations.
Other(explain):
REMARKS. Adjusted to show appropriate panel count on each string. Updated wire callout and electrical calc
Ft" OF CE USE ONLY +�
Routed to Perm' e ician: Date: �1 2-4.. (Qj Initials: /gyp
Fees Due: Y 0 No Fee Descriptio : Amount Due:
b
1/2, \N-15's/Nr t $
Special
Instructions:
Reprint Permit (per PE): ❑ Yes �o o Un
Doe
Applicant Notified: Date: c (01-V7() Initials:
I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012
FOR OFFICE USE ONLY—SITE ADDRESS:
This form is recognized by most building departments in the Tri-County area for transmitting information.
Please complete this form when submitting information for plan review responses and revisions.
This form and the information it provides helps the review process and response to your project.
City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT
Tr •n '
a smittal Letter
t i k,A r ij 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.ti y and-or v
TO: DATE REC "'VED:
DEPT: BUILDING DIVISION r
FROM:
Tia Wall OCT 1 8 2018
AH
COMPANY: Blue Raven Solar U'1 UILDNG t'" i IVIS4`,+
Aie
PHONE: 385-482-0045 By l�
RE: 12734 Southwest Morning Hill Court,Tigard, /f MST2018-00239
(6:4002411363223, United States / (Permit Number)
Peter Hedgecock
(Project name or subdivision name and lot nunr)
ATTACHED ARE THE FOLLOWING IT S:
Copies: Description: Copies: Description:
Additional set(s) of ►'t.J : x Revisions:
Cross section(s)and
1Wall bracing and/or lateral analysis.
Floor/roof framing. 1;' Basement and retaining walls.
Beam calculations. Engineer's calculations.
Other(explain):
RE MARKS: Changed layout solar panels.
.
FOR` FF . E USE ONLY
Routed to nechnic�an: Date: D Z / Initials: % f
Fees Due: s No Fee Descri tion: Amount Due:
$ 2, (fr/
Special
Instructions:
Reprint Permit(per PE): ❑ Yeso 111Done
<//
Applicant Notified: •••e --- Date: `p (L // Initials:
I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012
Date: 10/16/2018
Date of Review: 10/16/2018
Project Name: Peter Hedgecock--PERMIT#MST2018-00239
Address: 12734 Southwest Morning Hill Court,Tigard, OR 97223
1. Installers moved the single islanded module to a different mounting plane, to combine it with
another array.
Updated plans to show the layout that was installed.
Please reach out to me directly if you have any questions.
Scott Gurney
Senior Design Manager
scott.gurney@blueravensolar.com
385-498-4401
\Or.
The Future of Energy.ergy Today.
BLUE RAVEN
City of Tigard
13125 SW Hall Blvd.
Tigard, OR 97223 Tel: 503.718.2439
Location: Inspection Date:
12734 SW MORNING HILL CT, TIGARD,
OR, 97223
Record Type: Record ID:
Residential - Master Permit MST2018-00239
Inspection Type: Inspector:
199 Electrical final Jeff Grove
Result:
PASS
Comments:
Violation Summary:
Inspector Contractor
City of Tigard
13125 SW Hall Blvd.
Tigard, OR 97223 Tel: 503.718.2439
Location: Inspection Date:
12734 SW MORNING HILL CT, TIGARD,
OR, 97223
Record Type: Record ID:
Residential - Master Permit MST2018-00239
Inspection Type: Inspector:
299 Final inspection Jeff Grove
Result:
PASS - NoCofO
Comments:
Violation Summary:
Inspector Contractor