Plans (379) EI , SEP 1 1) 2018 CITY OF TIGARD lllL O DI1lIsioN BRIGHTWATER REDHAWK APARTMENTS 16194 SW 108' TIGARD, OR 97224 FIRE ALARM DATASHEETS OFFICE COPY CITY OP TIGARD REVIE D FOR CODE COMPLIANCE Approved: OTC: I ] Permit#: FP,_ca.a1 ?- ® o r ) ) ' Address: ) j g I t Prepared bys„ite#: Fire Systems Weft; Inc. -- Date: 9 Phone 360.693.9906 ' PLEASE PROVIDE COMPLETED NFPA 72 RECORD OF COMPLETION AT FINAL INSPECTION �r.sQ131=110it) •- . .. -• -• SK-4 & SK-4E Fire Control Panel Engineering Specifications The contractor shall provide a completely electrically supervised fire alarm control panel Silent Knight Model SK-41E.The system shall contain a fire alarm control panel capable of operating and supervising smoke detection devices,alarm notification devices, and an on- board annunciator.It shall be compatible with a digital communicator accessory. The fire alarm control panel shall have a power limited supply,four Class B initiation circuits which shall accommodate heat detectors, smoke detectors,and manual pull stations.Smoke detection shall be achieved with either 2-or 4-wire detectors that are compatible with the system.The initiation inputs shall be programmable as 1)verification zones in which detectors are automatically reset one time before signaling an alarm condition; or 2)combination waterflow supervisory zones that allows the FACP to distinguish between an alarm switch (waterflow device)and a supervisory switch (tamper) installed on the same circuit.The FACP shall have two 2.5 amp or 5 amp (with an additional optional standard transformer)programmable notification outputs. It shall have dedicated relays for alarm,trouble, and supervisory. It shall have two power outputs,one resettable and one non-resettable, each rated at 500 mA. The FACP shall have an on-board annunciator to indicate alarm,supervisory,trouble,and maintenance conditions.The annunciator must include LEDs for AC, GENERAL TROUBLE,ALARM SILENCE,WALK TEST, EARTH FAULT,AND LOW BATTERY.The annunciator shall also contain LEDs to annunciate fire alarms,troubles,supervisory, and maintenance by zone.The FACP must be fully operational from the annunciator and include buttons for ACKNOWLEDGE,ALARM, SILENCE, RESET,and WALK TEST.The annunciator must also have separate DISABLE switches for each zone and notification circuit. Electrical Specifications (cont) Battery Approvals SK-4XLM Type: Sealed lead acid only NFPA 72; UL Listed; LED Interface Module. Charging Circuit: 27.6 VDC @ 0.8A CSFM 7165-0559: 145; max normal flat charge MEA 297-01-E-3 SK-XRM24 Charging Capacity: 18 AH 110 Volt Transformer 3-6A. Size: 7 AH max allowed in FACP. Ordering Information Larger batteries can housed SK-4 SK-XRM24E in an RBB accessory cabinet 120 VAC Four Zone Conventional 220 Volt Transformer 3-6A. Compatible Initiating and NAC FACP SK-RZA4 Devices Remote Annunciator. See SK document PN 52612. SK-4E 240 VAC Four Zone Conventional SK-4XZM Mechanical Specifications FRCP Zone Relay Module. Cabinet Backbox Dimensions: 14.5"W x 15" H x 3" D Accessories RBB (36.83 W x 38.10 H x 7.62 D cm) SK-DP2/4 Remote Battery Box Accessory Cabinet Door: Dress Panel.Allows access to the Cabinet. Use if back up batteries are 14.677"W x 15.342" H x 0.375" D panel controls but restricts access to too large to fit into FACP cabinet. (37.28 W x 38.97 H x 0.95 D cm) system wiring. Dimensions: 16"W x 10"H x 6"D Cabinet Color: Red SK-CAC4 Digital Communicator Accessories Installation Class A Convertor. Converts Style B 51048 The SK-4/E can be surface mounted (Class B) IDCs to Style D (Class A)and Six-zone fire control communicator using two key slots at the top of the Style B (Class B) NACs to Style Z backbox and two additional 0.25" (Class A) 5129 diameter holes at the bottom, or semi- Four channel slave fire communicator flush mounted using the optional Trim SK-4XTM Ring P/N TR-1-R Transmitter Module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover KNIGHT all specific applications or anticipate all requirements.All specifications are FORM#350305 Rev.E subject to change without notice.For more information,contact Silent by Honeywell Knight 12 Clintonville Road, Northford,CT 06472-7161 ©2012 Honeywell International Inc. Phone: (800)328-0103, Fax: (203)484-7118.www.silentknight.com