Plans (2)
M EC2016 - 00223 PLUMBING FIXTURE SCHEDULE PLUMBING LEGEND N N O o THE FOLLOWING SPECIFIED FIXTURES SHALL BE USEDWHEN SHOWN ON THE DRAWINGS SYMBOL DESCRIPTION SYMBOL DESCRIPTION ABBREVIATIONS Ej n U MARK FIXTURE TRAP ARM C.W. H.W. REMARKS AD AREA DRAIN,ACCESS DOOR Q Obi U GATE VALVE lii1 ilii FLOOR DRAIN/AREA DRAIN = U 00 Ce RTU-3 EWC WATER COOLER 1-1/4" 1/2" - PROVIDE STOPS AFC ABOVE FINISH CEILING p N 125 MBH 'a FD FLOOR DRAIN 3" - •• PROVIDE SHUT-OFF VALVE �I- CHECK VALVE O ❑® FLOOR SINK AFG ABOVE FINISH GRADE R ECEIVED - r4 r 7j4"0 ?" LAV LAVATORY 1-1/2" 1/2" 12" PROVIDE STOPS PRESSURE AHU AIR HANDLING UNIT 0 -J M BFP BACKFLOW PREVENTERW MS MOP SINK 3" 1/2" 12" PROVIDE STOPS O, RD ROOF DRAIN MAR 3 0 2016 > ^G G ^G U BOP BOTTOM OF PIPE p L 1 S SINK 1-1/2" 1/2" 12" PROVIDE STOPS SOLENOID VALVE ;O,'ORD OVERFLOW ROOF DRAIN BOS BOTTOM OF STRUCTURE CI "Y OF TIGARD z a . UH-1 TSPV TRAP SEALER PRIMER VALVE 1/2" INSTALL BELOW LAV. CD CONDENSATE BUI .DING DIVISION m In o 60 MBH 0 II- RTU-5 7. WC WC 4" 1/2" PROVIDE STOPS GLOBE VALVE(STRAIGHT PATTERN) CO CLEANOUT 7i „ HOT WATER RECIRCULATION PUMP 72 MBH 4G WH WATER HEATER 3/4"OPEN SITE DRAIN 3/4" 314" PROVIDE STOP r CW DOMESTIC COLD WATER 1 G 2"(' ' 4D BUTTERFLY VALVE I L DD DN ET DOWN DRAINDECK L ) 0 2"G r J PLUMBING VEVT THRU ROOF ETR EXISTING TO REMAIN N BALL VALVE VTR EWC ELECTRIC WATER COOLER 7.740 MARK FIXTURE REMARKS r POINT OF CONNECTION FCO FLOOR CLEANOUT 16 GAS COCK (CONNECT NEW TO EXISTING) FFA FROM FLOOR ABOVE ' �1'LG BFP BACKFLOW PREVENTER WATTS-007M2QT-S ,' GAS SERVICE FP FIRE PROTECTION CO CLEAN OUT FLOOR:SMITH-4890PB. WALL: SMITH-4532S. -10I- PLUG VALVE FS FLOOR SINK RTU-1 DEMAND CALCULATION EWC WATER COOLER HALSEY TAYLOR HTV8BL-Q BI-LEVEL BARRIER-FREE COOLER.STANDARD FINISH. ( XXX ) PLUMBING EQUIPMENT DESIGNATION G GAS(NATURAL) 125 MBH , 7, RTU-4 OO FLOOR CLEAN OUT GCO GRADE CLEANOUT . 0 RTU-1 125 MBH FD FLOOR DRAIN SMITH 3"W/CHROME B-STRAINER#2010.TRAP PRIMER. INSTALL BELOW LAV. 7/4"G, 125 MBH FCO GPM GALLONS PER MINUTE RTU-2 125 MBH LAV LAVATORY AMERICAN STANDARD LAV.#0355.012 WITH CONCEALED ARM SUPPORT.#7400.172H GOOSENECK At -II#7723.018 DRAIN AND P-TRAP 17 GA. CHROME PLATED. INSULATED SUPPLIES&STOPS. WALL CLEAN OUT PLUMBING RISER OR DETAIL DESIGNATION HB HOSE BIBB RTU-3 125 MBH WCO HW DOMESTIC HOT WATER 77j4' RTU 4 125 MBH MS MOP SINK FIAT MOLDED STONE MOP BASIN#MSB-2424 w/WALL MTD FAUCET W/BACKFLOW PREVENTER HWR HOT WATER RETURN G #830AA.ADD STRAINER, CONNECTOR, HOSE BRACKET FIAT#832AA, AND MOP BRACKET FIAT#889CC. CO CLEAN OUT S SANITARY SEWER PIPING HWS HOT WATER SUPPLY • RTU-5 72 MBH ELKAY#BCR-15 SINK,AMERICAN STANDARD FAUCET#7400.172H & STRAINER, P-TRAP AND IE INVERT ELEVATION S SINK RTU-2 UH-1 60 MBH INSULATED SUPPLIES& STOPS. -k HOSE BIBB ST STORM SEWER PIPING MBH 1000 BTU PER HOUR 125 MBH „ TOTAL GAS DEMAND = 632 MBH TSPV TRAP SEALER PRIMER VALVE JOSAM 88250-90.10 CHROME PLATED&SHUT OFF VALVE.TRAP PRIMER AT ALL FLOOR DRAINSVENT PIPING N/A NOT APPLICABLE POST REGULATOR (DOWNSTREAM OF AMERICAN STANDARD#2467.100 CADET RIGHT HEIGHT 16.5"H 1.1 GPF ELONGATED, FREEZE PROOF WALL HYDRANT V ORD OSTT OVERFLOW ROOF DRAINSTORM OVERFLOW REGULATOR)NATURAL GAS SERVICE PIPING WC WATER CLOSET PRESSURE-ASSISTED TOILET WITH CHURCH SEAT 9400C LESS COVER WATER SUPPLY WITH STOP. - -V - VENT PIPING (BELOW SLAB) PD PUMP DISCHARGE IS BASED ON LOW PRESSURE , 7"W.C.WITH A INSTALL WITH FLUSH CONTROL ON WIDE SIDE. KI SHOWER HEAD. VBF PIV POST INDICATOR VALVE 0.5"W.C. PRESSURE DROP AND SPECIFIC WCO WALL CLEANOUT WALL: SMITH-4420U - - - COLD WATER PIPING PRV PRESSURE REDUCING VALVE GRAVITY OF 0.60. PIPING FOR LOW -I-3 ELBOW DOWN OW REV REVISION PRESSURE SYSTEM IS BASED ON A TOTAL STATE#PCE 10 1OMSA, 10 GALLON STORAGE ELECTRIC WATER HEATER MAX 2000W, - - HOT WATER PIPING RPM REVOLUTIONS PER MINUTE DEVELOPED PIPING LENGTH OF 250 FT. WH WATER HEATER 120 V. 1 PH.WITH AMTROL ST-5 EXPANSION TANK. 10 ELBOW UP H W RTU ROOF TOP UNIT PPR SQUARE TOO LLC. WM WATER METER A SEPARATE WATER METER SHALL BE PROVIDED FOR PIER 1 IMPORTS. -I 0 I TEE UP - - - - COLD WATER PIPING (BELOW SLAB) SAN SANITARY C/O MACEDRICH IMPORTANT NOTE: WATER METER TO BE 1" MAX.SIZE. CWBF SCW SOFT DOMESTIC COLD WATER ALL GAS PIPING IN THIS PROJECT IS SIZED INSHW SOFT DOMESTIC HOT WATER 401 WILSHIRE BLVD., #700 ACCORDANCE WITH THE 2009 UNIFORM I I TEE DOWN -H--1-W E- HOT WATER PIPING(BELOW SLAB) SDHWR SOFT RECIRC. HOT WATER SANTA MONICA, CA 90401 PLUMBING CODE,TABLE 12-8, BASED ON THE • 0 INDICATEDTOTALDEVELOPED LENGTHS. • I I HWR STRAINER HOT WATER RECIRCULATING PIPING ST STORM 310-394- 0 �' TFA TO FLOOR ABOVE ®GAS RISER III UNION FW FILTERED WATER PIPING TW TEMPERED WAT R OWNER SCALE:NTS -b REDUCER FILTERED WATER PIPING BELOW GRADE UH UNIT HEATER FWBF V VENT PIPE MEP Engineer of Record CAP GAS PIPING VTR VENT THROUGH ROOF Randall A. Nelson, P. E. GAS WCO WALL CLEANOUT -N-- FLEX PIPE CD CONDENSATE PIPING WH WALL HYDRANT 14817 West 95th Street I Lenexa, Kansas 66215 PLUMBING GENERAL NOTES: Phone 913 322 5150 1. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL BE IN CONFORMANCE WITH CONSULTANT © © O © ALL INSPECTION.APPLICABLE NATIONAL, STATE,AND LOCAL CODES HAVING JURISDICTION AND 2. COORDINATE THE COMPLETE INSTALLATION OF SYSTEMS TO AVOID CONFLICT WITH Q M Cr) OTHER TRADES. ffY CV I I I I 3. PROVIDE TO OWNER A COPY OF ALL REPORTS AND APPROVAL CERTIFICATES FROM I LI N / \ H I I 1 I LOCAL AND STATE INSPECTIONS AND ALL PLUMBING SYSTEMS EQUIPMENT MANUALS Ce SI,1 1D GS1 I INCLUDING WARRANTIES. 0Ce IO L J L_ __ - __ __ J 4. COORDINATE ALL ABOVE SLAB AND UNDER SLAB SANITARY,AND WATER PIPING 0 X11 U SYSTEMS TO AVOID CONFLICT WITH ALL OTHER TRADES SYSTEMS,AND COLUMNcr)c 3 e- N.0 �_ FOOTINGS. ALL SOIL AND WASTE PIPING SHALL BE GRADED TO A UNIFORM SLOPE C 4"S OF NOT LESS THAN 1/8" PER FOOT FOR PIPING 4"OR LARGER,AND NOT LESS THAN '7 Ie \ i`^O� V I J U CBFP) �, I I I EXISTING P P NG PRIOR O ROUGH-N1/4"PER FOOT FOR PIPING 3"OR LOF UNDER SLER. DLAB NSTALLATIONINATE FINAL RTS WITH 0 i� N la, \ 3`A^�G��® . I) tel-, I!IN r (CI I Og 5. COORDINATE ALL FLOOR DRAINS, CLEANOUTS,AND FLOOR MOUNTED FIXTURES (3 I'- 31A - �' c* I WITH FINISHED FLOOR SLAB ELEVATION TO ENSURE THEY ARE INSTALLED PLUM AND Z I C I - I FLUSH WITHOUT CRACKS, RISE IN THE SLAB, OR VOIDS AROUND GRATES OR TOPS. ILI H \ N K. II I J�\ a ■_ U ` ALL CLEANOUTS SHALL BE INSTALLED ALONG MAINS AT 50'-0" DISTANCE MAXIMUM. N 3 VTRJ I„. 1,1 I _ ' ALL FLOOR AND WALL CLEANOUTS SHALL BE ACCESSIBLE FOR MAINTENANCE ANDII) te (n (EWC) 30' U ( MS ) �I _ C4 _1 UH-1 NOT INSTALLED BENEATH EQUIPMENT. ANY DRAIN GRATES THAT ARE DAMAGED AS Q is = N 4..\\ 3/4"HW I 60 MBH A RESULT OF OTHER CONSTRUCTION PRIOR TO RELEASE OF THE BUILDING TO THE N U ^ OWNER SHALL BE REPLACED WITH LIKE GRATE AT NO EXPENSE OF THE OWNER. ^C� "1�\-3"V +,,, 1"G 6. PROVIDE TRAP AND SEAL PRIMERS ON ALL FLOOR DRAINS IF REQUIRED BY CODE OR arAye11Ull S NV' _ 7. Z > J P101 P101 U N N 7,2'v > N I I I ,IO OWNER. 0 C N � N. N `] it 2"G 2"G 7. PLUMBING VENTS THROUGH THE ROOF ARE TO BE LOCATED AT A MINIMUM OF 5'-0" a U ( s ) > ( FD ) I s 1 I- I FROM BUILDING PARAPETS AND 10'-0" FROM FRESH AIR INTAKES AND AS REQUIRED Lna ----- :in N (LAV) . u a li 1� I TO MEET LOCAL CODES. ~ (EWC) > 11 8. ALL EXPOSED PIPES PENETRATING FINISHED WALLS SHALL BE EQUIPPED WITH WALL JLZ in �! CMS ) A ❑ I ,_ - _ -_ _ / 10 ESCUTCHEONS. 5.-) (LAV) U > %lIIS ��\ - -1 l �� 9. PROVIDE FINAL CONNECTIONS FOR ALL EQUIPMENT SPECIFIED IN PLUMBING ) N a ( WC) P ^5 ` I-II 11 I 1 II ii ' - - , _0_ - \ r-% � I FIXTURES AND EQUIPMENT SCHEDULES ON THESE CONSTRUCTION DOCUMENTS IN O J en N I �J!���� N -I V / , U j ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. PROVIDE ALL REQUIRED ri ( FD ) rI�S�� SHUT-OFFS, BACKFLOW PREVENTERS, PRESSURE REGULATORS,AND CONDENSATE > cn4 4 ��� DRAINS INDICATED ON PLUMBING SCHEDULES AND AS REQUIRED BY LOCAL CODES ® ,1 © I I \ \ iiki ll) FOR COMPLETE EQUIPMENT INSTALLATION. CONSULT EQUIPMENT SUPPLIER ORCe W ��WATER RISER 2"S (LAV) U 1 OWNER FOR ADDITIONAL FINAL CONNECTION REQUIREMENTS NOT SHOWN ON 5 SCALE:NTS (LAV) co iv p^5 ( �� THESE DRAWINGS. co r 1-1/4"G N' - U " r 10. PLUMBING FIXTURES SHALL BE AS SPECIFIED ON THE PLUMBING FIXTURE SCHEDULE > \ 1n 5 1 1-1/4"G Li ' 1,,, -2"G- \ I IN THE DRAWINGS. PROPOSED SUBSTITUTIONS WILL BE ACCEPTED FOR REVIEW AND N N ti 1 I APPROVAL. SUCH APPROVAL TO BE IN WRITING BY PIER 1 BEFORE INSTALLATION. a > \ 1"G c, 1-1/4"Gn N 2„S ( FD ) U (WCO)� co N - I- fr • iv A^`� S iy 125 M-4 � RTU-5 °m MBH ' , ( WC7 w 125 MBH II �4.4 72 MBH r N I 0�I I erg OF <1 ARD M El � � L_J -� I - Lr- 11 PLUMBING KEYNOTES: (Oi , z0,0) REVIEWED • •A[PLTANC$ it b^5 1. CONNECT NEW 4"SANITARY INTO EXISTING SANITARY IN THIS AREA. FIELD A>»n� ' " �� VERIFY EXACT CONNECTION POINT, LINE SIZE, MATERIAL AND INVERT PRIOR 01 C: ; i CAosad lid lO 11 LR )WASTE & VENT RISER 1 I TO START OF WORK. 4 1-1 "G- 1-1/4"G Pemilt#�i y oIlo` 1 1 SCALE:NTS `i �� ' 2. CONNECT NEW 1"DOMESTIC COLD WATER INTO EXISTING LANDLORD Ad Item Ok %v 1110hE & a ALL GAS LINES r PROVIDED DOMESTIC COLD WATER STUB. FIELD VERIFY EXACT Sw'e# - �' TO BE ROUTED CONNECTION POINT, LINE SIZE, MATERIAL AND WATER METER : rril .... Y Y , • ON ROOF REQUIREMENTS PRIOR TO START OF WORK. BY ib: Data rn4J et_I�j 3. INSTALL NEW 3"VTR. COORDINATE INSTALLATION WITH LANDLORD'S L_ -. RTU-1 I A R�2 REPRESENTATIVE AND MAINTAIN A MINIMUM OF 10' FROM ALL FRESH AIR OFFICE COPY - M 125 MBH INTAKES. 125 MBH \\1 I 4. ROUTE NEW 2"GAS LINE BACK TO EXISTING GAS METER BANK. COORDINATE ROUTING WITH LANDLORD'S REPRESENTATIVE. ENSURE EXISTING METER IS LARGE ENOUGH FOR NEW TOTAL LOAD OF 632 MBH. IF METER IS FOUND NOT I J OI 1 TO BE LARGE ENOUGH COORDINATE WITH LANDLORD'S REPRESENTATVE - (- - 0 I 0 I I -)o - �❑ L� A 12 AND GAS UTILITY FOR INSTALLATION OF NEW. J U��L co -I- i ri �u 1"CW - - � � L - JH - -1 L - J © I (BFP) H �i I �n ) �- J OL ( FD ) iii: OLL �L - _ - - - - - Jr WH r - - 1 =I I L - � ( WH - r� ( MS ) u u ( Ms ) II u u 01/29/2016 PLAN CHECK 2 r 31N L,- - - - - -, I I 12/29/2015 PLAN CHECK SUBMITTAL � � � >� � � � L C12�1 I .X.,4 =-, J II I ` ) a II © � v REV. DATE DESCRIPTION tn;V L I 91 , H COMBINATION TEMPERATURE VACUUM RELIEF VALVE (WC ) �� I �� O ill L - - - - - - - - - AND PRESSURE RELIEF 3/4"HW TO FIXTURES P II sr �� L J VALVE 3/4"CW SUPPLY �5ED PROF-4.S 3/4"CW I ii P S ) ( FD ) a 3. © 6' �� J.] �� c..co G 1NF Si3/4"HW 1 ®-> I R _ 6 13 TEMPERATURE& I� • 1 �a 54t, �/ c-PO4�� rn _ 0 O ■ 79504PE LAV _ ) iId p I 1PRESSURE RELIEF \_ BALL VALVE M - O I _ _ _ DRAIN DISCHARGE CHECK VALVE II (LAV) o , �1e1 -- TO MOP SINK EXPANSION TANK-SEE �, OREGON L - - y 1-1/2"V L - - (EWC) scs\ lig Q. J r (EWC) r _ -2"S- SPEC. 3 153/9 (EWC) _ J L - 16 GAUGE GALVANIZED //78k (� in 1 - - (LAV) °1i r 1 F - - SAFETY PANT DIP TUBE INSIDE EXPIRES: DEC. 31, 2016 v I I V OF TANK aHDI ( FD )�- �� ( - DRAINVALVE; moi �, III JAIPLUMBING PLANS, ( wc ) IG ( Wc)( j 1'�1I T DETAILS AND SCHEDULES T I I I / ( I 1 1 I L - J L - _ J --ll L J L - J I- WALL ' SHEET TITLE i HT7T77% rT- 7T -1I IT- 7T7I�-' I �,i r /- FT- 7 -T Av II 14 1 // �� // II II II II II 11 V\ 1 ����///�/ II II II II II II \\ - - � - - 15030 // // // I i - II II II II II II \�\ II II 11 II II II \A L - [ JOB # k/2":\- // 111 77 II I I I I I I i� REFERENCE ARCHITECTURAL 1 11 II 11 II 1 II II 11 Il 11 11 DRAWINGS FOR PLATFORM 12/29/15 -LI-tJ 1 'J-LI U I tJ i=t1 U IJ-I-LI I I A SPECIFICATIONS DATE ( I3/4" DRAIN- DISCHARGE TO I I I FLOOR SINK ENLARGED PLAN P 101 (3)WATER scALE:,/a"=,'-o'• 12�WASTE & VENT ENLARGED PLAN PLUMBING OVERALL PLAN O WALL MOUNTED ELECTRIC WATER HEATER \ /SCALE:1/4"=1'.0" \ I J SCALE:1/8"=,'-0" SCALE:NTS SHEET # COPYRIGHT© 2015 MECHANICAL LEGEND DIVISION 15 - MECHANICAL 15.10 ALL DUCTWORK IN NON-CONDITIONED, CONCEALED SPACES SHALL BE INSULATED. INSTALL DUCTWORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION ABBREVIATIONS 15.1 PIER 1 IMPORTS HAS AN EXCLUSIVE NATIONAL ACCOUNT RELATIONSHIP WITH CARRIER TO SUPPLY HVAC ACCORDING TO LOCAL CODE AND LATEST EDITION OF SMACNA MANUAL. DUCTWORK SHALL BE SPIRAL OR N N 0 c PRODUCTS. NO SUBSTITUTIONS ALLOWED. HVAC CONTRACTORS ARE DIRECTED TO CALL AND ASK FOR PIER 1/NATIONAL RECTANGULAR METAL WHERE EXPOSED TO VIEW. PROVIDE INTERNALLY LINED INSULATION FOR THE FIRST 10 L.F. OF N 0 N L; IPLANS. AFF ABOVE FINISHED FLOOR ACCOUNT PRICING. FOR FURTHER ASSISTANCE, RE: CONTACTS TABLE,ARCHITECTURALSUPPLY AND RETURN AIR DUCT. HOLD DUCT WORK 8'-6"MINIMUM FROM THE INSIDE FACE OF ALL PERIMETER WALLS IN BTU BRITISH THERMAL UNITTHE SALES AREA. wimi ® DIFFUSER EQUIPMENT (SEE SCHEDULE) CFM CUBIC FEET PER MINUTE 15.2 DRAWINGS AND SPECIFICATIONS SHALL BE PREPARED AND SEALED BY A PROFESSIONAL ENGINEER. DRAWINGS U COMP COMPRESSOR X SHALL INCLUDE, BUT NOT LIMITED TO,THE INFORMATION CONTAINED IN THE PIER 1 IMPORTS"ANYWHERE USA" 15.11 WHERE DROP CEILING IS USED, FLEX DUCT MAY BE USED FOR LAST 5'-0"BEFORE REGISTER. V1 • Q 0 RETURN AIR - DB DRY BULB PROTOTYPE DRAWINGS. FURNISH AND INSTALL A COMPLETE AND OPERABLE HEATING AND AIR CONDITIONING SYSTEM . + v EQUIPMENT NUMBER DN DOWN 15.12 A SEPARATE HVAC SYSTEM SHALL BE PROVIDED FOR THE STOCKROOM/OFFICE/RESTROOM AREA. J m GRILLE OF SUFFICIENT CAPACITY TO MAINTAIN A YEAR ROUND SPACE TEMPERATURE OF 72 DEGREES FAHRENHEIT AT AMBIENT LU DX DIRECT EXPANSION DESIGN TEMPERATURE LISTED IN THE 1%OCCURRENCE COLUMN OF THE ASHRAE FUNDAMENTALS GUIDE. UNIT SIZES RETURN OR INDICATES DETAIL PLAN, SECTION, AND/OR EACH SHOWN ON DRAWINGS ARE PRELIMINARY AND SHALL BE VERIFIED FOR LOCAL CONDITIONS. EQUIPMENT SIZING AND 15.13 AFTER STARTUP OF EQUIPMENT,THE AIR DISTRIBUTION SYSTEM SHALL BE BALANCED IN ACCORDANCE WITH HVAC • z 0 > II EXHAUST DUCT DIAGRAM(APPLIES ONLY WHERE INDICATED EAT ENTERING AIR TEMPERATURE SYSTEM DESIGN SHALL COMPLY WITH ASHRAE STANDARDS AND LOCAL CODES AND ORDINANCES. HEATING AND PLAN, SMACNA STANDARDS AND PROCEDURES. PIER 1 MUST RECEIVE ACCEPTABLE REPORT BEFORE THE PUNCH LIST C I�� UP ON DRAWINGS) EFF EFFICIENCY COOLING LOAD CALCULATIONS SHALL INCLUDE SITE SPECIFIC"R"VALUES FOR THE BUILDING ENVELOPE, LIGHT FIXTURE IS COMPLETE. • m o 6 I ISI SUPPLY DUCT INDICATES DRAWING ON WHICH ESP EXTERNAL STATIC PRESSURE TYPE AND QUANTITY SHOWN ON DRAWINGS,AND OTHER LOAD FACTORS REQUIRED BY LOCAL PRACTICE. COPIES OFLO I ISI DETAIL APPEARS ETC AND SO FORTH COMPLETED WARRANTY REGISTRATION DOCUMENTS, OPERATION AND PARTS MANUALS, MAINTENANCE PROCEDURES 15.14 PLUMBING FIXTURES SHALL BE AS SPECIFIED ON THE PLUMBING FIXTURE SCHEDULE IN THE DRAWINGS. -� UP EX EXHAUST AND AIR BALANCE REPORT SHALL BE PROVIDED TO PIER 1 IMPORTS. PROPOSED SUBSTITUTIONS WILL BE ACCEPTED FOR REVIEW AND APPROVAL. SUCH APPROVAL TO BE IN WRITING BY L, PIER 1 BEFORE INSTALLATION. 0 II�� INDICATES TYPICAL DETAIL DEGREES FAHRENHEIT 15.3 THE CONDENSING SECTION OF THE HVAC EQUIPMENT SHALL INCLUDE CONDENSER COIL GUARD, N SUPPLY DUCT �- � (APPLIES TO ALL CONTRACT FLA FULL LOAD AMPS ANTI-SHORTCYCLE TIMER, CRANKCASE HEATER, 30 DEGREE LOW AMBIENT HEAD PRESSURE CONTROL, HIGH AND LOW 15.15 FIRE PROTECTION SYSTEMS AND ROOF DRAINS SHALL BE APPROVED BY PIER 1 PROJECT MANAGER BEFORE DOWN TYP \ DRAWINGS) FPM FEET PER MINUTE PRESSURE CONTROL SWITCHES AND 5 YEAR COMPRESSOR WARRANTY. PROVIDE FACTORY APPLIED ELECTROFIN COIL INSTALLATION. Fr X INDICATES DRAWING ON WHICH 15.16 FIRE PROTECTION AND FIRE ALARM SYSTEMS SHALL BE PER CODE AND BE APPROVED BY PIER 1 IMPORTS BEFORE RETURN OR �1 GPM GALLONS PER MINUTE COATING FOR BOTH EVAPORATOR&CONDENSOR COILS BETWEEN 0-5 MILES OF COASTAL AREAS. DOWN DETAIL DUCT DETAIL APPEARS GRS/LB GRAINS PER POUND 15.4 PACKAGED UNITS SHALL BE FURNISHED WITH MANUFACTURER'S INSULATED MOUNTING CURB. ROOF PENETRATIONS IN EXISTING STRUCTURES SHALL BE PERFORMED BY THE ORIGINAL ROOFING CONTRACTOR. INSTALLATION. STROBE REQUIRED-CEILING OR WALL MOUNTED WITHIN 6"OF DOOR OPENING. PENDANT/UPRIGHT HP HORSEPOWER HEADS TO BE USED AT ALL ROOMS EXCEPT IN AREA/ROOMS WITH LAY-IN TILE WHICH WILL RECEIVE RECESSED HEADS. INDICATES SECTION NUMBER0 HZ HERTZ ROUND DUCT IN INCHES 15.5 AIR HANDLING SECTION SHALL HAVE FORWARD CURVED FAN, DIRECT EXPANSION COIL WITH THERMAL EXPANSION VALVE, FILTER SECTION WITH 30% EFFICIENCY,2"THICK PLEATED MEDIA FILTERS AND GAS FIRED HEATING SECTION. 15.17 IF A FIRE ALARM OR SPRINKLER SYSTEM ARE REQUIRED TO BE MONITORED BY ANY APPLICABLE LAW, DOWN INDICATES ON WHICH DRAWING KW KILOWATT REGULATION, OR CODE THEN LANDLORD WILL PERFORM ANY SUCH MONITORING UNLESS STATED OTHERWISE IN THE * ij SECTION APPEARS MBH THOUSANDS OF BTU PER HOUR LEASE. IF PIER 1 MONITORS THE FIRE ALARM SYSTEM PER THE LEASE THEN LANDLORD MUST INSTALL A SYSTEM (� ROUND DUCT MIN MINIMUM 15.6 FIRESTATS OR SMOKE DETECTORS AS REQUIRED BY CODE SHALL BE FURNISHED AND INSTALLED BY THE COMPATIBLE WITH STANLEY. REF. CONTACT ARCHITECTURAL PLANS TO OBTAIN INFORMATION ON REQUIRED FIRE `� Y UP A INDICATES REVISION & NUMBER NEC NEGATIVE MECHANICAL CONTRACTOR.WIRING SHALL BE DONE BY THE ELECTRICAL CONTRACTOR. ALARM SYSTEM, COMPATIBLE EQUIPMENT, DEDICATED POWER,TELEPHONE LINES,AND DIALER FOR MONITORING NTS NOT TO SCALE CONNECTION. OA OUTSIDE AIR 15.7 GAS HEATING SECTIONS SHALL BE POWER VENTED WITH AUTOMATIC, INTERMITTENT ELECTRIC SPARK IGNITION. ■ al e OBD OPPOSED BLADE DAMPER BURNERS AND HEAT EXCHANGER SHALL BOTH BE STAINLESS STEEL WITH 5 YEAR NON-PRORATED WARRANTY. CONNECT NEW TO EXISTING OC ON CENTER 15.8 ALL RTU'S SHALL BE THE HIGHEST SEER/EER OF MANUFACTURER'S EQUIPMENT AT THE TIME OF CONSTRUCTION. ill VANED ELBOW PH PHASE PSI POUNDS PER SQUARE INCH REFRIGERANT OR COOLING SYSTEM MUST CONFORM TO THE LATEST REQUIREMENTS OF THE LATEST ENVIRONMENTAL # SHEET NOTE NUMBER PSIG POUNDS PER SQUARE INCH GAUGE REGULATIONS. v r\J LOW PRESSURE RH RELATIVE HUMIDITY FLEX DUCT SA SUPPLY AIR 15.9 THERMOSTATS(TME-CVS)AND REMOTE SENSORS(TME-RRS)ARE BY LIGHTSTAT-RE: CONTACTS TABLE, X I XXX (TYPE ICFM SH SENSIBLE HEAT ARCHITECTURAL PLANS. NO SUBSTITUTIONS ALLOWED. MOUNT THERMOSTATS AND SENSORS AS SHOWN ON PLAN. 45 TAKEOFF SP STATIC PRESSURE WIRING SHALL BE 7 CONDUCTOR#18 AWG CABLE FROM RTU TO THERMOSTAT. PROVIDE 2 CONDUCTOR#18 AWG CABLE FITTING p TEMP TEMPERATURE FROM THE THERMOSTAT TO THE REMOTE SENSOR.ALL WIRING TO BE CONCEALED IN EMT CONDUIT. PPR SQUARE TOO LLC. U-V�" UNDERCUT TYP TYPICAL ll MANUAL VOLUME DAMPER UC VOLT UNDERCUT VOLTAGE 401 WILSHIRE BLVD., #700 n C/O MACEDRICH W/O WITHOUT SANTA MONICA, CA 90401 WET BULB 310-394-6000 WB WC WATER COLUMN PACKAGED ROOF TOP R-410A UNIT SCHEDULE ♦ AIR DEVICE SCHEDULE , OWNER © MEP Engineer of Record APPROVED ALTERNATE FOR TITUS PRODUCTS: CARNES or KRUGER M L Randall A. Nelson, P. E. DESIGNATION RTU-1-4 RTU-5 MARK TYPE MFG/MODEL FINISH REMARKS/LOCATION SERVICE SALES STOCKROOM A DRUM LOUVER TITUS/DL WHITE OPPOSED BLADE DAMPER/SALES&STOCKROOM 14817 West 95th Street MANUFACTURER CARRIER CARRIER B CEILING DIFFUSER TITUS/TDC WHITE LAY-IN OPPOSED BLADE DAMPER/OFFICE&BREAK r n r Lenexa, Kansas 66215 MODEL NUMBER 48HC**08 48HC"06 Phone 913 322 5150 C CEILING DIFFUSER TITUS/TDC WHITE SURFACE MOUNTED OPPOSED BLADE DAMPER/ CONSULTANT APPROXIMATE NOMINAL SIZE-TONS 7.5 5 RESTROOMS, CORRIDOR&VESTIBULE ARI RATED-CFM 3,000 2,000 24"X24"LAYIN RETURN IN OFFICE AND BREAK RM. 1 MINIMUM OUTDOOR AIR-CFM 430 125 D RETURN GRILLE TITUS 50F WHITE 12"X12"SURFACE MTD. IN WALL @ OFFICE&BREAK RM. I I I I 0 M cc 12"X12"SURFACE MTD. IN DOOR© ELEC. &STORAGE 24"X24"LAY-IN RETURNN STATIC.-INCHES W.C. .8 .8 48"X36"SURFACE MTD. @ STOCKROOM DOOR N. OUTSIDE AIR OPTION SINGLE ENTHALPY SINGLE ENTHALPY GRILLED'/PLENUM RETURN AIR FILTER TYPE/THICKNESS C/2" C/2" 'REFER TO PLAN FOR GRILLE SIZE AND AIR FLOW (TYPICAL) I , LU 'CEILING AIR DEVICES ARE 24"x24"FACE SIZE UNLESS OTHERWISE INDICATED O - • I - ---- r-��ra■ I �� T 20016CY GROSS CAP-BTUH 83,660 54,200 •CEILING AIR DEVICES ARE TO BE RATED FOR MAXIMUM NC-30 4'-0" 9 9 = O WALL AIR DEVICES-PAINT FINISH TO MATCH ADJACENT WALL COLOR TERMINATE WITH GO- I m Q ° AFF z COIL E.A.T.-DB/WB-DEG F 80/67 80/67 ' , EF-3 ® _it1 4'-0"AF• I \ or ARI RATED NET CAP-BTUH 88,200 60,000 • r f If O (1) 0 0 / 12"x12"TRANSFER I _ __ � •• U FULL LOAD SEER/EER NA/ 12.0 15.2/ 12.5 GRILLED'AT 14'-0"AFF ILL 1 @ 0 350 A f UH-1 0 z ce Q EXHAUST FAN SCHEDULE ,,,� ," EF-2, REFRIGERANT PURON PURON 50<.�,t0 Q i�-1 FUEL GAS GAS MARK CFM MFG/MODEL FINISH REMARKS/LOCATION DAMPER w '� �I "`' 110x12 18x6 350 A ��,- 18x6 LLI 11 z MAXIMUM GAS INPUT-MBH 125 72 EF-1 100 BROAN/676 WHITE DUCT THRU ROOF AND TERMINATE WITH (TYPICAL) �;, liii -, ` = 10x12 a UNIT HEATER- 12"x12" MOUNT UNIT GOOSENECK MIN 24"ABOVE ROOF/RESTROOM350 A z ifiMAXIMUM ELECTRICAL INPUT-KW N/A N/A EF-2 100 BROAN/676 WHITE DUCT THRU ROOF AND TERMINATE WITH �� i , GRILLE'D AT ITRANSFER rL 18x6 RIGID DUCTWORK 350 A j ATI 13'-0"AFFTH M 48"X36"TRANSFER GRILLES'D'ON EACH I MINIMUM CSA THERMAL EFFICIENCY-PERCENT 82 82 GOOSENECK MIN 24"ABOVE ROOF/RESTROOMPAINT'A', TYP. I CONNECT TO LCP AND SWITCH TO STOR. RM. LIGHT 114'-0"AFF I 18x6 SIDE OF 48"X36"TRANSFER DUCT AT 14'-O" (/) EF-3 350 BROAN/504 WHITE DUCT THRU ROOF AND TERMINATE WITH GOOSENECK ■u AFF ON WALL ABOVE DOOR-WHERE Q MINIMUM STAGES OF HEATING 2 1 t MOUNT THERMOSTATS MIN 24"ABOVE ROOF/STORAGE F��1_rg '�`I REQUIRED, EXTEND DUCTWORK AND VOLTS/PHASE 208/3 208/3 O `1••J - - , (FOR RTU'S 1,2,3,4,5)AT 0©/ INSTALL FIRE DAMPER IN PENETRATION at Q CONNECT TO ELEC. RM. LIGHT, INCLUDE T'STAT, I3 EVAPORATOR FAN HP 2 4 2 g EF-4 350 BROAN/504 WHITE DUCT THRU ROOF AND TERMINATE WITH GOOSENECK 10 - -e- 11 48"AFF. QQ�Q It a 10 re MIN 24"ABOVE ROOF/ELECTRICAL ROOM N O COMPRESSOR QUANTITY/RLA 2/13.6 1/15.9 ■ RET a Ln O CONDENSER FAN QUANTITYMP 2/.25 y.25 ' EXHAUST FANS TO BE INSTALLED BY ELECTRICAL CONTRACTOR INT• •- - LOW . • OM a PROVIDE - •- NING IN TOP OF • MINIMUM CIRCUIT AMPACITY 41 29 - I r COVER WITH 1/2"X1/ "GALVANIZED -• \K.' SP if S MAXIMUM OVERCURRENT PROTECTION 50 40 UNIT HEATER SCHEDULE FURRDOVVN ■ • • • • ■ :• • • THERMOSTAT(LIGHTSTAT TME-POI) YES YES BELOW, REMOTE SENSOR (LIGHTSTAT TME-RRS) YES NO MARK MODEL BTUH EFF. FLUE SIZE GAS PIPE SIZE FAN HP ELEC. WEIGHT 0ri w PREFABRICATED INSULATED ROOF CURB YES YES UH-1 LF24-60 60,000 80% 4" 1/2" .10 115/1/60 87 LBS k d 30x6 Ai NON-FUSED DISCONNECT SWITCH, FIELD WIRED YES YESEE ' ' x `� 'GAS FIRED UNIT HEATER BASED ON LENNOX PRODUCT _ 471 _ N - w BURGLAR BARS YES YES • FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR • . S Cie w SUPPLY&RETURN SMOKE DETECTOR YES YES C) ' PROVIDE THERMOSTAT - . S‘2,4a, AN ' :■• CO2 SENSOR-DUCT MOUNT YES YES 0 ■ 0 �� _ HAIL GUARD YES YES ELECTRICAL SYMBOLS / 4,4,,a,, 11x6 1 •11 II 'A175-0 ' ■ee' 11 1-1 EXTEND 30"X18"RETURN AIR DUCT DOWN INTO OPEN SHIP WEIGHT-POUNDS 1,500 1,000 •• - • • •- SPACE BELOW DECK AS SHOWN. PROVIDE 26"X36" REMARKS: MARK DESCRIPTION • • •- • - - • ri- • _ THERMOSTAT OPENING IN TOP OF DUCT COVER WITH 1/2"X1/2" T THERMOSTAT-LIGHTSTAT TME-CVS '• - ■ GALVANIZED HARDWARE CLOTH. MOUNT TOP OF DUCT PIER 1 IMPORTS HAS AN EXCLUSIVE NATIONAL ACCOUNT RELATIONSHIP WITH CARRIER TO SUPPLY HVAC 0 ARCHITECTURALin •- • 7"BELOW BOTTOM OF STRUCTURE.-TYPICAL OF(4) C PRODUCTS- NO SUBSTITUTIONS ALLOWED. HVAC CONTRACTORS ARE DIRECTED TO CALL AND ASK FOR PIER 1 • RTU-1 ' SALES CC NATIONAL ACCOUNT PRICING. REFER TO CONTACT INFO ON ARCHITECTURAL PLANS.ALLOW FOR 6-8 WEEK RS REMOTE SENSOR-LIGHTSTAT TME-RRS "© , LEAD TIME.ADD 2 WEEKS MORE FOR COIL COATING, SEE NOTE BELOW. 20x20 I . Lai i S SMOKE DETECTOR IN RETURN/SUPPLY AIR DUCT FOR RTU'S-1,2, 3,4, &5. e PROVIDE DOWNFLOW UNITS UNLESS OTHERWISE SPECIFIED. AS REQUIRED BY CODE E.S.P.CONSISTS OF SUPPLY AND RETURN AIR DUCTWORK AND ASSOCIATED AIR DEVICES. IT DOES NOT N INCLUDE INTERNAL PRESSURE LOSSES DUE TO COILS, FILTERS, HEAT EXCHANGERS, MIXING PLENUM, GENERAL NOTES: N DAMPERS AND OTHER DEVICES INCLUDED AS PART OF THE UNIT. N COOLING CAPACITIES ARE NET CAPACITIES.ADD FAN MOTOR HEAT TO OBTAIN THE TOTAL COIL COOLING THERMOSTATS AND REMOTE SENSORS TO BE LIGHTSTAT. PROVIDE THERMOSTAT/SENSOR MODEL 18x6 -Ii LOAD. TME-CVS-RRS BY DYNELCO(800)-292-2444.WIRING TO BE 7 CONDUCTOR#18 AWG CABLE FROM RTU TO 1 1 A 475 TO - • I I • _ • THERMOSTAT. PROVIDE 2 CONDUCTOR#18 AWG CABLE FROM THERMOSTAT TO REMOTE SENSOR. RUN AIR FLOW RATES ARE ACTUAL AIR QUANTITIES BASED ON SITE ELEVATION, NOT STANDARD AIR. THERMOSTAT WIRING IN EMT CONDUIT WITH AN EXTRA 15 FOOT OF WIRE FOR REMOTE SENSORS. ,2 - • - -a t2 THE SCHEDULED ELECTRICAL POWER VALUES ARE BASED ON THE MANUFACTURERS DATA FOR THE CONTRACTOR MAY SUBSTITUTE SPIRAL DUCT OF EQUIVALENT CAPACITY IN LIEU OF RECTANGULAR DUCT SCHEDULED MODEL. SIZES. b1_186 FILTER TYPE: DISPOSABLE PLEATED MERV 7 INSULATE DUCTWORK IN NON-CONDITIONED CONCEALED SPACES WITH 2"THICK 3/4 LB DENSITY, FOIL FACING& A 500 OUTDOOR AIR OPTIONS: PROVIDE SINGLE ENTHALPY OUTDOOR AIR ECONOMIZER WITH BAROMETRIC RELIEF. VAPOR SEAL w/FASTAPE#0808. PROVIDE INTERNALLY LINED INSULATED SHEET METAL FOR THE FIRST 10 L.F. ABBREVIATIONS: OF SUPPLY AND RETURN AIR DUCT. 18x6 E.A.T.-ENTERING AIR TEMPERATURE SEAL ALL SHEET METAL DUCT JOINTS&SEAMS w/IRON GRIP#601 AND GLASS MESH FS-150. A1475 I' I R.LA.-RUNNING (RATED) LOAD AMPERES •E.S.P.-EXTERNAL STATIC PRESSURE ROOFTOP AIR CONDITIONING UNITS(RTU)SHALL HAVE INSULATED CURBS. I I1 14x14 1 DUCTWORK DIMENSIONS SHOWN ARE INSIDE CLEAR AIR FLOW DIMENSIONS. MOUNT DUCTWORK AT 13'-0"MIN CO• -I 18x6I AFF @ STOCKROOM. MOUNT BOTTOM OF DUCT WORK© 14'-6"MIN. IN SALES AREA. 1 A 500 18x6 1 it A 500r 18x6 i 00 / / RUN 1 1/4"(U.N.O.) INSULATED DRAIN FROM EACH ROOF TOP NC UNIT TO NEAREST ROOF DRAIN. l11 I --- -- I Al 500 Al 500 • STRUCTURE MECHANICAL CONTRACTOR SHALL INSTALL SMOKE DETECTORS IN SUPPLY&RETURN AIR DUCTS AS REQUIRED O i BY CODE FOR UNIT SHUT-DOWN. _ y ---1 / RECTANGULAR DUCT 13 16i' LJ �� 13 01/29/2016 PLAN CHECK 2 SPIRAL DUCT • 12/29/2015 PLAN CHECK SUBMITTAL -��,..- Nr REV. DATE DESCRIPTION SECTION ROTgj��N - , L.N...... / :pi p�FF �/ GAS CONNECTION L I I �°'�� I:F SriO i ��/ F� , 4O,' ROOFTOP UNIT 5PE Q% OPPOSED BLADE p RIGID INSULATION VOLUME DAMPER LL ti VP EON t\AT II DRUM LOUVER ¢ I PREFABRICATED ; L� (TITUS DL) c INSULATED ROOF CURB NOTE: I .il ii,, OA INTAKE HOOD = ALL EXPOSED DUCTWORK AND DIFFUSERS //1W/li ROOF DECK TO BE PAINTED"A"FINISH ABOVE JOISTS. ROUND OR RECTANGULAR SUPPORT HANGER ,�,�' EXPIRES: DEC. 31, 2016 - SUPPLY AIR DUCT, SEE PLAN PER CODE PROVIDE UNIT I.D. ON TWO SIDES 14 _ _ _ _ � FLEXIBLE CONNECTION,TYP ■■ 14 LINED RA DUCT :� o LfljjDSADUCT `- -- -- - PLAN VIEW -' HVAC PLAN AIR FLOW DETAIL NOTES: TYPICAL INSTALLATION DETAIL TO BE APPLIED TO ALL ROOFTOP UNITS. THIS DETAIL IS DIAGRAMMATIC ONLY, ILLUSTRATING MAJOR I I L SHEET TITLE COMPONENTS AND INSTALLATION REQUIREMENTS. I 15030 JOB # DATE OPEN GRID CEILING 12/29/15 45 DEGREE ENTRY SUPPLY AIR BOOT / / 0 1 1 0 M101 ©DRUM LOUVER DETAIL STOCKROOM QSUPPLY AND RETURN AIR DUCT DETAIL SALES AREA 0Sc :HVAC PLANSHEET # SC : NTS SCALE' Nls 1/8" = -0" COPYRIGHT© 2015