Loading...
Plans (122) M EC2018 - 00348 GENERAL NOTES I - -, r___._._______ co . o 1 . NEW / REMODEL CONSTRUCTION CUTTING & PATCHING BY GENERAL SRV VCR SRV VCR Z CONTRACTOR. 27L 27/1 i - - . N 2. INSTALLATION WILL COMPLY WITH 2014 OREGON MECHANICAL SPECIALTY CODE _ -� I Z ° O N� ,� (OMSC), 2014 OREGON STRUCTURAL SPECIALTY CODE (OSSC), 2014 OREGON �- ENERGY EFFICIENCY SPECIALTY CODE (OEESC) ASHRAE STANDARDS, AND BOILER _ U� I` =_oo� MANUFACTERER'S INSTALLATION INSTRUCTIONS. ~ AWA' rn N�'r� 1 . 0_0(.11-,-..; 3. ALL MATERIALS & PRODUCTS USED WILL BE NEW UNLESS OTHERWISE DIRECTED 1i I Q El Nzo)< i 1 W I v v p �X BY THE OWNER. ALL EXISTING FLUE VENTING AND HOT WATER PIPING TO 1 rr-,,----) o v �� REMAIN, UNLESS OTHERWISE DIRECTED BY THE OWNER. - - - 4"0 HWS ['—� a 4. OPERATION AND MAINTENANCE MANUAL(S) SHALL BE PROVIDED TO THE BUILDING II 4"� HWS - .�' OWNER BY THE MECHANICAL CONTRACTOR IN ACCORDANCE WITH SECTION KB- 1 I411 B- 1 )- z- E 503.2.9.3 OF THE OEESC. � I x = •. � ' I 10"0 VENT L 10 P THRU -"O VENT � -} �. h r UP THRU E 1-C f �Tta� REQUIRED SCOPE O F WO K ROOF ! I __.. - 2 1 HWS ,MAIN - J i , ---- HWS MAIN State Of Oregon S �lctural Special ROOF I 2 „0 HWS `_ `� Specialty Code HWR MAIN "0 HWS ❑ Concrete and Reinf rcing Steel FT DEMO EXISTING B-2. X B-2 of T�7, 4 4" B-2 " -i HwR 'MAIN " J � Bolts Installed in Co creta FURNISH AND INSTALL NEW WEIL-MCLAIN BOILER TO REPLACE B-2. „ �l � ;i;'%,/1 ir_ �► 10 VENT �Q- : // � � /,/, 10 VENT ��� ; ❑ Special Moment-Re fisting Concrete Frame UP THRU (1-4:',/////,'� //, ,/,� UP THRU I CONNECT NEW RIELLO RS38 E BURNER TO EXISTING GAS SERVICE WITH ROOF Lr``� /.,1L_Z/J ROOF I i ❑ Reinforcing Steel& restressingSteelTendons L �. _._._ _._ '� ❑ Structural Welding 1 -1 /2"� SERVICE. � ❑ Hign-StrenghtBoltin .711 RECEIVE 1, I� ._ ❑ Structural Masonry I . - --� - � ', r ❑ Reinforced Gypsum oncrete ; — EX 1 r�>_ ❑ Insulating Concrete F ii MAY 7 2018 ❑ SprayAppiied Fire-REsistive Materials CITY®FTIGARI➢ INA BUILDING DIVISION (P/ / -2 !_�te 0 P-2 ❑ Pilings, Drilled Piers and Caissons ❑ Shotcrete ❑ Special Grading,Exc ation and Filling ., ❑ Smoke-Control `j+ Syste s e, ❑ Other InspectionsI I 1/Ler?‹ 1 " 6 E x''10 "o ,' /A/7A4Lid.t4 4 J ' , i,ii 5- . I`3 tea)/f � c._ nv -r- k if y"� W ' , I S \1 _ DI S \AB DIR / A -A 1 I 276 I 276 W U x 1/4 f- 1 I 1i 1 (J n/ ' / .�r1P.36'>`-+ 5,/ -�I / sir X r A9/ flDATAL 2 \ 3 FL00 � PLA \ EXST \ G HVAC 2ATIAL 2 \ 3 FLOO LA \ \ EW - VAC M102 /4" = 1'-0" M 100 1/4" = 1'-0" W< CD Q CL U_ to t O W 7 (r o � yAO CR z (r) Q Ct.-9 O a 144Y 15 2: 114 1 . I I W °0 �- f' r 51 •f' S OFFICE COPY o CITY of'rIGARD O REVIEWED FOR CODE COMPLIANCE m Approved - j CP OTC: j J clo t r I k% Q -- -- - Pcrtrut#: 0 O 0 Address: 1L308Sw''6R ..--A- 3 3 1 LES ATTACH V E \ T DETAIL suite#: .---_ M102 N.T.S. By . 7)J Date: _ O U EXISTING HOT WATER BOILERS • CAPACITY WATER SIDE OPER ASME ELECTRICAL FUEL FLUE OPER SYMBOL MANUF MODEL AREA SERVED LOCATION MBH GPM PRESSURE EWT LWT PRESS RATING V/PH TYPE CAPACITY DIA WEIGHT NOTES LEGEND (GROSS IBR) DROP(FT.) F DEG. F DEG. PSIG PSIG (MBH) INCHES LBS B-1 WEIL-MCLAIN H588-W BUILDING HEATING WATER MECHANICAL 275 1,126 75 1 150 180 18 50 120 V/ 1 PH/60 HZ/ 15 AMP NAIL GAS. 1,356 10 3,430 PROJECT LOCATI0N REVISIONS E EXISTING B-2 WEIL-MCLAIN H588-W BUILDING HEATING WATER MECHANICAL 275 1,084 FIELD VERIFY 30 80 120/ 1 NATL GAS. 1,357 10 3,490 1, 2 NOTES: 1. INSTALLED MARCH 1989. -r-' :11.',,,, L.r ',1.--:;'-. ,. x DEMO t - : i 0 2. NO CHANGES TO B-1. 0 NEW 4. 14 ,I "t �.. :i r 7t , t.d 7 yy CONNECT TO NEW HOT WATER BOILERSA EXISTING CAPACITY WATER SIDE OPER ASME ELECTRICAL FUEL FLUE OPER «:5 4 ' — SYMBOL MANUF MODEL AREA SERVED LOCATION MBH GPM PRESSURE EWT LWT PRESS RATING V/PH/HZ/BREAKER TYPE • I `' t CAPACITY DIA WEIGHT NOTES ` . DATE: 04/20/2018 USE OF HUNTER-DAVISSON, INC. DRAWINGS, GROSS IBR) DROP FT F DEG. F DEG. PSIG PSIG (MBH) INCHES LBS � rL�° ,` r,j ,�611�psk •r� $. ` � Q FILE: SPECIFICATIONS AND OTHER DOCUMENTS ( ( ) - B-2 WEIL-MCLAIN H588-W BUILDING HEATING WATER MECHANICAL 275 1,126 75 1 150 180 18 50 120 V/ 1 PH /60 HZ/ 15 AMP NATL GAS. 1,356 10 3,430 ? �' "," JOB: - These Drawings, Specifications and other documents are prepared - - .. N —_ by Hunter-Davisson, Inc. for this Project and unless otherwiseI ; - 1 ,µF t n DWN: RM CHK: JD2 provided, Hunter-Davisson, Inc. shall be deemed the author of `� § �'" ' NOTES: °° d tBrinary i :, q these documents and shall retain all common law, statutory and . f 4-4-1-1< tnter. c� 2ND FLOOR PLAN: R.{ • I �, - AREA OF WORK ; 1*1 HVAC other reserved rights, including the copyright. The Owner shall be a • permitted to retain copies of the Hunter-Davisson, Inc. Drawings, F — Specifications or other documents for information and reference in k ;� . , ` connection with the Owner's use and occupancy of the Project. '� ' 5 � . The Hunter Davisson, Inc. Drawings, Specifications or other � � ' : x V 1 0 2 documents shall not be used by the Owner or others on other �, v ,As [�� ,; projects, for addition to this Project or for completion of this ;;,' Agreement, except by agreement in writing and with appropriate IA 4. - -Ilia - L_L compensation to Hunter-Davisson, Inc. 1 OF 1 SHEETS