Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (83)
FPS2O17 - 00092 C L Q E y k� m v 8 Ki0 (9 a _ c Ca g P'] d llS S c a, LLI p1 O 0 r...,„ ,, Q A i LINCOLN I E 1-.., q,„ aArn o -.. fl Orn dam EL 3 802 s CCin LIJ(1) o H a ,3va 2 PORTLAND AUTISM CENTER m W 1 1 m RECEIVED t JUN 1 9 2017FIRE ALARM SYSTEM $ CITY OF TIGARD 2 BUILDING DIVISION • N J O k� a 3, mk N t SITE INSTALLER DRAWING INDEX U N DWG# DESCRIPTION LINCOLN 1 CAPITOL ELECTRIC FA-001 COVER SHEET 1 t 1300 S GREEN B U RO RD 11401 NE MARX ST FA-002 GENERAL INFORMATION FA-101 DEVICE PLACEMENT PLAN & CALCULATIONS i TIGARD , DR 97223PORTLAND OR 97220 FA701 WIRING TYPICALS j g n E PHONE : 971 -506-3072 1 g I CONTACT: DAN WILSON 3 i 3 I g WE i. vg- s a I �¢i. LLIg UE 2. T I Cl) 1 ce a DM Z CO 7. m w � 1 Li.' J r 1 0 C-9o Ups Jia ou) Ct z c) C7 0 a —1 EL _jZ2 � , 4 ci: .2 1 i N 4 E LI Li LII 8 a c g a m C42 "S Z O i _N SCO O m Zrj) g C LULL C s i } CO • S a eu E doi z S _ CITY 3 OP T1GARD °- FOR COII OMPUANCE Adrovect (1!_ . I tr. :..‘Q,Cv -} 'T;-- Permit ii1/4 Address: a 4b '' , g - a St> Z 6305 SW ROSEWOOD ST, SUITE A $ �.� ' Date: o;. �-\t o CO LAKE OSWEGO, OR 97035 5 r1:`: tliC (L) M OFFICE COPY 6. SimplexGrinnellPHONE: 503-683-9000 a SERVICE. 503-683-90© DRAWN D J. JOHNSON 2; CHECKED BY: J. JOHNSON FAX. 503-675-6521 ISSUE DATE: 6115117 JOB#: a t PROJECT#: 448:600370601 §i SIMPLEXGRINNELL© 2017 1 TM SYSTEM: FIRE ALARM SYSTEM 4 Safer. Smarter. Tyco. tt SHEET: i SALES REPRESENTATIVE SCHEDULING DRAWINGS PREPARED BY COVER SHEET BRYAN ADAMS FAITH KASKE JEFF JOHNSON 111 503-683-9000 503-683-9000 503-683-9000 m N y zi,fn :- 23 bradams@simplexgrinnell .com fkaske@simplexgrinnell .com jefjohnsonsimpIexgrinneII .com o T FA-001 N x NICET LEVEL IV #1218468 2 IIIliii =r-. G ---\ ERA_ \ OT-S SYST- v D =SCR1 DT 0 \ SCONE OF WORK SYvBOE KEY E t CI)cCC) w 1011441 co. m ft. co,terLcp-c) E a OCCUPANCY TYPE: B BUSINESS GROUP 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF z CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES �'� SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. SPRINKLER PROTECTION: BUILDING IS FULLY SPRINKLED IA ¢EL._ 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJORe..) ,_ E -o DTO IMPAIR THEEVIATIONS IN TCONSTRUCTION SCHEDULEHE WORK SHOWN, THE . DEVICES SHALL CONTACT SIMPLEXGRINNELL IN A TIMELY MANNER SO AS NOT DMODIFY EVICES EAXISTING S SHOWNREONALARM DRAWINGS.EM: PROVIDE NEW DEVICES, RELOCATE AND DEMO EXISTING FRE ASA N SYN 30LS LEGE\ CO C ji 1� �'' i-CO 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING i opo AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY DESIGN IS FOR FIRE ALARM NOTIFICATION IN THE OUTLINED AREA OF WORK. SYN 3OL ESC IPTIO\ v10 EE 3AC COX �o� AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. N co LI 0M 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR ALL NEW WIRING TO BE CLASS B. NAC EXTENDER PANEL 1 E �"'� INSTALLATION. 1 ' NACU' # DESIGNATES THE NAC PANEL NUMBER SIMPLEX 4009-9201 SUPPLIED BY SIMPLEXGRINNELL " �o� 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE I n rt co 5 BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO W / 6.2AH BATTERY SET SIMPLEX 2081-9272 Iry c o Y Y MQw ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. C j `�J v' N PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. I Fl MANUAL PULL STATION SIMPLEX 4099-9001 SINGLE GANG BOX 2 1/2" DEEP N 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO • SIMPLEXGRINNELL NO LATER THAN 7 DAYS AFTER FINAL TEST. 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER. SMOKE SENSOR / BASE SIMPLEX 4098-9714 3 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED SIMPLEXGRINNELL TECHNICAL REPRESENTATIVE. ® SIMPLEX 4098-9792 BASE 4" OCTAGONAL BOX 1 1/2" DEEP = 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE a FIRE ALARM INSTALLER. a 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ISI WALL MOUNT MULTI-CANDELA STROBE ONLY WHITE SIMPLEX 4906-9103 4" SQUARE BOX 1 1/2" DEEP ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. # =CANDELA RATING m 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH8 C CEILING MOUNT MULTI-CANDELA V/0 WHITE SIMPLEX 4906-9104 HANDY BOX 1 1/2" DEEP °' MANUFACTURER'S INSTRUCTIONS AND NEC. FIRE ALAR R V A CAB -_ COD -_S & STA\ DARDS # =CANDELA RATING 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC). 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. Eil CEILING MOUNT MULTI-CANDELA A/V WHITE SIMPLEX 4906-9130 4" SQUARE BOX 1 1/2" DEEP o 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE C # =CANDELA RATING FPLP. - 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATE MORE THAN ONE FLOOR OR CABLES INSTALLED IN END-OF-LINE RESISTOR 3.3K (EOL) SIMPLEX 4081-9002 OREGON FIRE CODE, 2014 EDITION VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. END-OF-LINE RESISTOR 4.7K (EOL) SIMPLEX 4081-9003 2 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET EOLR END-OF-LINE RESISTOR 6.8K (EOL) SIMPLEX 4081-9004 SUPPLIED BY SIMPLEXGRINNELL LOCATIONS. OREGON MECHANICAL SPECIALTY CODE, 2014 EDITION END-OF-LINE RESISTOR 10K (EOL) SIMPLEX 4081-9008 -@ 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOOR SHALL BE INSTALLED IN ACCORDANCE WITH OREGON ELECTRICAL SPECIALTY CODE, 2011 EDITION m NFPA 70 ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE. NOTE: EXISTING DEVICES SHOWN SHADED FOR REFERENCE. g 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. NATIONAL FIRE ALARM CODE (NFPA 72), 2013 EDITION 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. E 22. MAINTAIN 40 PERCENT CONDUIT FILL RATIO AS PER NEC REQUIREMENTS. 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY, HOWEVER, ANY EXISTING CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. SIMPLEXGRINNELL MAKES NO - STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. . a m L O O d gO JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. s a W RE SC - 111E ABBREV AT 0 \ S L-G -\ 9 3 t 3 `o U AC = ABOVE CEILING HT = HEIGHT C = CEILING MOUNTED HVAC = HEATING, VENTILATION, & AIR CONDITIONING = 0 E = EXISTING TO REMAIN IMS = INFORMATION MANAGEMENT SYSTEM 0 RC = EXISTING TO REMOVE AND COVER MAX = MAXIMUM R S - R AG RA v RD = EXISTING DEVICE TO BE RELOCATED MIN = MINIMUM o RL = RELOCATED DEVICE N/A = NOT APPLICABLE 0 RR = REMOVE EXISTING AND REPLACE W/NEW NAC = NOTIFICATION APPLIANCE CIRCUIT EXTENDER FRE ALAI\/ W I E LIST WP = WEATHERPROOF NECNDU == NATIONAL ELECTRICAL RK DISPLAY UNIT GENERAL NOTES: CIRCUIT DESCRIPTION RISER RATED: FPLR SINGLE CONDUCTOR(THHN,TFFN) PLENUM RATED: FPLP XP = EXPLOSION PROOF NFPA = NATIONAL FIRE PROTECTION ASSOCIATION V VISUAL/SIGNAL CIRCUIT SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE H = HIGH HUMIDITY NIC = NOT IN CONTRACT 1. DEVICES SHOWN ARE TYPICAL. SEE FLOOR PLAN d- AFF ABOVE FINISHED FLOOR NPU = NETWORK PROCESSING UNIT FOR QUANTITY AND LOCATION. SPARE C V4 I I I 2 CONDUCTOR 14 AWG AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH T Q, AHJ = AUTHORITY HAVING JURISDICTION NTS = NOT TO SCALE SOLID ANIXTER PART NUMBER (2) #14 AWG ANIXTER PART NUMBER 2. ALL WIRING SHALL COMPLY WITH NFPA 70, ARTICLE N FA-1402C-1-1N-03-BX AREA=0.0097 SQ. INCH (EACH) FA-1402C-1-2N-03 ALM = ALARM PAP PRE-ACTION PANEL 760, POWER LIMITED SYSTEMS. V3 - ANN = ANNUNCIATOR SCC = STATUS COMMAND CENTER SPARE NAC7 CONDUIT SIZE CONDUCTOR AREA CONDUIT SIZE CONDUCTOR AREA BMS = BUILDING MANAGEMENT SYSTEM SLC = SIGNALING LINE CIRCUIT 3. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. (N25) O V (RL) (RL) 4009 w 1/2" 0.12 SQ INCH * 1-1/4" 0.60 SQ INCH * CBC = CALIFORNIA BUILDING CODE SMK = SMOKE EDLP © c-�� : ��� " V2 I it 3/4" 0.21 SQ INCH * 1-1/2" 0.82 SQ INCH * CD = (eg. 15CD) CANDELA SUPV = SUPERVISORY KEYED NOTES: C C . .C `C I U N 1" 0.34 SQ INCH * 2" 1.34 SQ INCH * CSFM = CALIFORNIA STATE FIRE MARSHAL TAC = TRUEALERT ADDRESSABLE CONTROLLER 1 RECONNECT RELOCATED & NEW DEVICES TO EXISTING (RL) O ELECTRICAL RM c r . 40% FILL PER N.E.C. DET = DETECTOR TRBL = TROUBLE O CIRCUIT. SEE FA-101 FOR EXACT WIRE ROUTING. MAINTAIN (N24) .. (RL) V- V o DGP = DATA GATHERING PANEL TS = TAMPER SWITCH SUPERVISION. EOLR S c V1 THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED ELECTRICAL EOL - END OF LINE TYP - TYPICAL Uc �� c E CHARACTERISTICS AS WELL AS CODE REQUIREMENTS. ALTERNATE SUPPLIERS MAY BE EPO = EMERGENCY POWER OFF UON = UNLESS OTHERWISE NOTED 0 072 SUBSTITUTED PROVIDING EQUIVALENT CHARACTERISTICS ARE MAINTAINED. ITEMS SUCH AS FACP = FIRE ALARM CONTROL PANEL VCC = VOICE COMMAND CENTER o t2ovAC CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT FATC = FIRE ALARM TERMINAL CABINET VT = VALVE TAMPER 2ND FLOOR D DESIGN OF THIS SYSTEM INSTALLATION. FBO = FURNISHED BY OTHERS WF = WATER FLOW D It FCC = FIRE COMMAND CENTER W = (eg. 1/2W) WATT REFERENCE https://www.anixter.com/customer/tycofs FOR SG ANIXTER CABLE DATA FAA = FIRE ALARM ANNUNCIATOR W/ = WITH OC N o FR = FIRE ALARM TRANSPONDER W/O O = WITH OUT °- FSD = FIRE SMOKE DAMPER CID CO m o z zN LU Zcm C DEV CE AD : .ISS \ G �_ � -\ � S -Q � -\ SE OF OD =RAT 0 \ -� Q Qfni2 t vo O r V O c i z U O12 J o � �/ co E Zp 0oQ J zoo ___ICONTROL UNIT ANNUNCIATION NOTIFICATION FIRE SAFELY CONTROL . `° i� sa ADDRESSABLE CARD (IDNET OR MAPNET) - O`� •�� TII Q - DEVICE ADDRESS P •��n �O �P w POS N, \, O��QO� `O��P\`)PSS Oc�Q c��Pv`' 000�� ®_ E 1. �� OCG �P �P\ �� �C,Q O � 5� c§) �')L- Q ��� ��C, �\O �P� P� \�O\0�� c'� Q�A GSL Q<;' 4O,�F (', ' JC 0 0 ,*R OSP �P Ory �� ��C7 c�G `�p�JP P�\O c�J �JQ `O�' O� O�� �� `�Q' `P� c Q ADDRESSABLE DEVICES NUMBERING O 5 c �<5 ��cD'`) �Q, �� OC,P PC' PGJ `O �O ��� 0 �cC'P `O� �5 :2 ` 13 �� � QQ�QQ� OJ0OJOc<\9 Q. N. Q\ OP ��Q' Q P C) C) OSP PO���F OS <Q Q�P\SCY\�0� S cP �Q' C,- `O< `.\\ P O� k\) 'i)00 P o 0\-\\ � J00 O��J0�0 O��000 QUO \' \' \'' QZ SOHO PC, ��PS�J �Q:;:c, S\O�P OOH ZJ� 0�5Q C, P C-) P G P QQ PZ' P� P c� ` Q O 5 -C P�' P�/ P P� P� P P��J JPF• `����\��� c'Q. c'F. POS S\O��P POS `�,Z� Qct '\k' a O G/ G, G, G/ G.`J G,\J G�� G• G.\ �� P� P� FSS �```9' 4 P� �� �� P� ON'' <)O (D -CIRCUIT DESIGNATOR P P P P P P P P P �� •\� Q, P <c F O z SYSTEM INPUTS A BCD E F GH I J K L M N OP QR S T U V W X Y Z AA AB AC AD AE AF AG AH AI AJ REMARKS i 4009 NAC PANEL O, 1 SMOKE SENSOR/DETECTOR • • 1 0 76- r DEVICE DESIGNATOR 2 MANUAL PULL STATION • • • _ • • 2 w N 14- 1 3 DUCT SENSOR/DETECTOR • • • • • 3 0 4 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR • • • • • • • • • • • 4 O° 5 ELEVATOR LOBBY SMOKE DETECTORS (EXC. MAIN FLR.) • • • • • • • • • • • • • 5 0 w VISUAL. AUDIBLE OR A/V DEVICE 6 ELEVATOR MECH. ROOM HEAT DETECTOR • • • • • • • • • • 6 > 7 ELEVATOR MECH. ROOM SMOKE DETECTOR • • • • • - • 7 I- 8 ELEVATOR SHAFT HEAT DETECTOR • • • • • • • • _ • 8 o 9 ELEVATOR SHAFT SMOKE DETECTOR • • • • • • • • • • • 9 i 10 ELEVATOR POWER MONITOR • • • • • • - • 10 E o 11 FIRE ALARM AC POWER FAILURE • • • • 11 w E 12 FIRE ALARM SYSTEM LOW BATTERY • • • • • 12 c' s 13 OPEN CIRCUIT OR GROUND FAULT • • • 13 = 14 CLASS B NOTIFICATION CIRCUIT (NAC) - SHORT • • _ • 14 15 15L 16 16 2 17 17 0 rn 18 18LU 19 19 20 20 0 o E co 21 21 -i 22 22 = a o N 23 23 co 2 u 2424 0 25 25o 26 26 I- 27 - 27 DRAWN BY: J. JOHNSON t z 28 28 CI_ 29 29 c CHECKED BY: J. JOHNSON ts 30 30 ISSUE DATE: 6/15/17 31 31 JOB#: 1 E 32 32 A BCD E F OH I J K L M N 0 P QR S T UVWX Y Z AA AB AC AD AE AF AG AH AI AJ PROJECT#: 448:600370601 0 SIMPLEXGRINNELL© 2017 E .- SYSTEM: ` -...G FIRE ALARM SYSTEM ' co 0 SHEET: m GENERAL INFORMATION 8 FE Im U m O m C: N E W O0 m W cD i U m Q FA-002 z X cr . o 0 � Cr 1 2 GENERAL NOTES: 1. ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED A� X OTHERWISE. �Y 2. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. CT)Oe- aii.QCD CV 0 0 LO L ccoC . U KEYNOTES: p p m Lc) o Ol TIE INTO EXISTING NAC CIRCUIT N24. MAINTAIN SUPERVISION. aillic -6 w Z Qo_ T TIE INTO EXISTING NAC CIRCUR N25. MAINTAIN SUPERVISION. 0 � a - OLU 113 \ iii �o`- x 0 w N OCeCI) (7----„ , r* .1-----'\„ C13 CO Li C5.2 g Ul I: 2 ) ( 3 ) (4 ) }r , 0 i t ® n13 ) 4_11.7 ) Ai_JIZIIIII - O U A � K c„,,,>- i "IP i Y .-._._..__ -_ ..... ..._.................................. _. ._....._._. _ .._ ....__._.._.................... ......_...._...._._..._........--- _._ 1__._.....- _ _ ..__.... ..._....---- -_ ._.. ._ _-.........._............_..._._- _ ...__...-.._._.._ ._.. - "c , .._ I -_ -- moi - _ __- .._- I -. _ ....._ ._.._... ......__. _ ...... _ _._..... _ • _- ._ ci 2 cn m ! ' BREAK OFFICE 1 f I 204 i E 212 E 1511 i OFFICE OFFICE STORAGE i OFFICE OFFICE OFFICE 15 li OFFICE N25-9I :- •••• '1 203 15 205 206 207 208 211 213 I EOLR C J I I N24-17 C •7---, ,,--- , v I 11 C 11 1I:1 I I 1 • i l (RL) II I f.,,,\, (--- __ • ; ,, .„.„ m 7,-- rl--- f, I I f 1 V 1 ll ♦ , r \` I - I J tl ' ((( j t • • 1 N24-16 15 V N2 �f o / r1 :: i I jf T1 l ' i i 1 52 5 HALL i I V I C j 11 214 I 75 O I ; C i 1 l\ (RL) •CLOSETI m s / a N24-15 OPEN 209 ` •• 1 OPEN OFFICE j OFFICE X15 j 30 30 (RL) 30 vi •• 75 • 201 '- ,,. 1 202 Cq 30 �q 75 ,+ 7 N25-8 �q o I __._.._ - C Q N24-18 (RC) C N25-1 i1 C I , C C EOLR N25-3i =- - - _ l '.�15 • J o V 1 (TN (RL)• C • C -' m m 1, WAITING ' w pm , OPEN AREA SENSORY I uPM j ,----1 OFFICE ( 210 /' OFFICE • • • 201 �` I m �� • - 0 21 E I i r A: ,i I� ® 15 15 2 15 . - \ i / M2-35 0-�- j M2-39 i O x( N24-12 • I M2-37 Q 24-7 Q O N25-4 x dv12-38 C • • i L`J 1 C V (LV C I V � OFFICE I !.......:1......: ... 30 ]�r� .. € ...._ .. - I `, M2-36 201 v ® T. N24-14 )2(1 1 V I! 1 15 F a I _ 1 OFFICE C 11 . 1• 15 /� E ..�/ C i I I s i ' • I• / 124-6 / V ,ALN. ' ��� ---. 20 ; a V N24-9 C ® /' M'-31 Q , : _ i' .�1 75 • m • . 15• S • • ii g-- M H. z ' A7 ..,gi,.., c - • • -30 � I UP EN />/:_V C E N24 10 Xi ITE ? DH,, 3 / MZ�30 ; I ' ( € - OFFICE ' ' N24-11 C OFEN V ; ( ' - 2fl0 • g 15 �.---, C r _ 1 �, `' I OFFICE I 0 M2 4 • ,-� OFFICE o OFFICE WORKROOM - • 201 • V i V �, 1 _ i •. 204 /'� N24-8 �� x15 t4_2\ 15 ! i I 202 205I• / M2-33 ,..„,...---/N24-1 - SER I CC I VER V h :r 4 V • • -� • L. -I r 205 F I I - ■11 ; / �.. i- I I .. 'V I ' � , 1 I a OFFICE 1 a ' ' II K I1 ` y I I - - -- - 2,-' 1 y 207 N24-13 )( .v � ` \ +� sI C `' € 1 3 u N ;5 I s_.- t II • I L C OFFICE OFFICE I• L'I OFFICE N25-6 1 •5 L/ V I i �r l 2O3 3 ��� 203 202K III 15 1l I _15 ►24-3 BREAK I1 - C • M2-40 ® / .,a 15 204 DECK I M2-34 I ( • i 245 V i ( I _ - _ -- - _ - _. - C - - _. _ _.. - --' ' I o N 244 I C - o y • I [ ! m II I i s ! I I II i: • - o o ••• m • 1 a I !• I C 1 • 1 i : i• t I i I• j vN 1 I 11 s i v o 7 45 u_ PLAN w NORTH o O m U M 41)) DEVICE P �CENE\T PLA\ - 2ND FR EAST SCALE: 1/8" = 1 -O" m a Vtip 0 4 8 16 C/) € a) (IN FEET) L U I- E P p N N It t Q o C z 0 LI_ m Q M E m NAC7 - 2ND FLOOR EAST ELECTRICAL ROOM 4009 NAC VOLTAGE DROP SUMMARY Z Z N Standby Total Alarm Total Plan Z < L QtyDescription StandbyCircuit Description Load % Drop LU = Module P Current Current Alarm J N24 2ND FLOOR EAST NOTIFICATION SIG24 1.932A 17.33% O '- Ur 0 s Panel Equipment N25 2ND FLOOR EAST NOTIFICATION S1G25 1.200A 7.09% Z - s c) N26 SPARE SIG26 0.000A 0.00% ��// -J C3 ,21 U 4009-9201 1 4009 IDNET NAC EXTENDER, 120 VAC 0.0850 0.0850 0.1850 0.1850 L.L. (n € Panel Totals 0.0850 0.1850 N27 SPARE SIG27 3.00 Total 7 O U O Q nNotification Appliances Setting P1 - ' ,I 4906-9104 17 V/O MC NON-ADDRESS, WHT, CEILING 15 0.0000 0.0000 0.0750 1.2750 POINTS SHOWN SHADED REFER TO EXISTING DEVICES. 1••` 4906-9104 1 V/0 MC NON-ADDRESS, WHT, CEILING 30 0.0000 0.0000 0.1250 0.1250 N24 Distributed Load Voltage Drop g 4906-9130 1 A/V MC NON-ADDRESS, WHT, CEILING 15 0.0000 0.0000 0.0860 0.0860 I 4906-9130 3 A/V MC NON-ADDRESS, WHT, CEILING 30 0.0000 0.0000 0.1320 0.3960 Allowable % Drop: 17.9% Wire Res. Per Ft. 0.003070 CO 75' Celsius 3 4906-9130 5 A/V MC NON-ADDRESS, WHT, CEILING 75 0.0000 0.0000 0.2500 1.2500 Wire Gauge: 14ga Min. Device Voltage: 16.vdc o s Peripheral Totals 0.0000 3.1320 Starting Voltage: 19.5vdc % Voltage Drop 17.33% o , Circuit Capacity 2.A r 6 Added Current for EPS Conversion of 24 to 29 Volt IDNac Devices 0.0000 0.0000 Normal Operation m RUI Totals 0 0.0000 0.0000 Distance Device Voltage Voltage At m Address Totals 0 Addresses 0.0000 0.0000 Device # PID Setting (Feet) Current Drop Device 7. System Totals*: Standby_ 0.0850 Alarm 3.3170 N24-1 4906-9104 15cd 25 0.075 0.297 19.20 0 O N24-2 4906-9104 15cd 18 0.075 0.502 19.00 z N24-3 4906-9104 15cd 22 0.075 0.743 18.76 s O Standby Standby Alarm Alarm N24-4 4906-9104 15cd 20 0.075 0.952 18.55 7. u_ N24-5 4906-9130 15cd 19 0.086 1.143 18.36 w. Battery Set #1 (Cabinet/Charger #1) Current Total Current Total -) N24-6 4906-9104 15cd 33 0.075 1.456 18.040 } Select ALL Power Supplies on this battery set: N24-7 4906-9104 15cd 34 0.075 1.763 17.74 m a 09 0 4009 0.0850 3.3170 N24-8 4906-9130 75cd 31 0.250 2.029 17.47 a U.1 m Sub Total 0.0850 3.3170 N24-9 4906-9104 15cd 35 0.075 2.275 17.23 2 CO o N24-10 4906-9130 30cd 31 0.132 2.479 17.02 zI g N24-11 4906-9104 15cd 29 0.075 2.646 16.85 Total 0.0850 3.3170a N24-12 4906-9104 15cd 22 0.075 2.763 16.74 Fc U o Y 24 Hrs x 0.0850 = 2.0400Standby N24-13 4906-9104 30cd 51 0.125 3.010 16.49 w 2 Standb Time = Ah o N24-14 4906-9130 30cd 31 0.132 3.136 16.36 Alarm Time = 5 Min 0.08333 x 3.317 = 0.2764 Alarm Ah N24-15 4906-9130 75cd 40 0.250 3.267 16.23 2.3164 N24-16 4906-9104 15cd 39 0.075 3.334 16.17 Additional Spare Battery Capacity = 0% + 0.0000 N24-17 4906-9104 15cd 15 0.075 3.353 16.15 a U 2 2.3164 N24-18 4906-9130 30cd 33 0.132 3.380 16.12 2 co Battery Discharge Factor = 20% + 0.4633 Totals: 528 Ft. 1.932A Lu s Minimum Batte Re wired a `° rY q 2081-9272 6.2AH (2x) 2.7797 0 0 M Battery Supplied 2081-9272 6.2AH (2x) w EP * System Totals represent total system current requirements. Those currents may be distributed between multiple battery sets or power supplies as N25 Distributed Load Voltage Drop < o N shown above. In o Allowable % Drop: 17.9% Wire Res. Per Ft. 0.003070 © 75' Celsius Li Wire Gauge: 14ga Min. Device Voltage: 16.vdc z Starting Voltage: 19.5vdc % Voltage Drop 7.09% DRAWN BY: Fc Ckt Capacity 2.A CHECKED BY: J. JOHNSON m t-- Normal Operation ISSUE DATE: 6/15/17 Distance Device Voltage Voltage At JOB#: Device # PID Setting (Feet) Current Drop Device PROJECT#: 448:600370601 s o N N25-1 4906-9130 75cd 42 0.250 0.309 19.19 SIMPLEXGRINNELL© 2017 E - N25-2 4906-9104 15cd 27 0.075 0.467 19.03 SYSTEM: N25-3 4906-9104 15cd 25 0.075 0.601 18.90 N25-4 4906-9104 15cd 35 0.075 0.773 18.73 PLAN FIRE ALARM SYSTEM NORTH m _N25-5 4906-9104 15cd 40 0.075 0.951 18.55 SHEET: i 02 N25-6 4906-9104 15cd 48 0.075 1.143 18.36 4111A17X, K EY P LA\ N N25-7 4906-9130 75cd 44 0.250 1.298 18.20 N25-8 4906-9130 75cd 32 0.250 1.362 18.14 DEVICE PLACEMENT PLAN & N25-9 4906-9104 15cd 44 0.075 1.382 18.12 _- WO SCALE: NTS CALCULATIONS = E Totals: 337 Ft. 1.200A P0 o m cp N_ in w E N W 0 m U U CO FA-101 Z m co m 2 DEVICE MOUNTING HEIGHT REFERENCE (PER NFPA 72) END—OF—LINE RESISTOR CODES 6 VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS A/C SUPPLY I I ,I I j 1� 1. MIN DISTANCE IN SLEEPING ROOMS IS 24" (610mm) FROM CEILING TO OR RETURN NOTE: REFER TO PANEL/MODULE AND DEVICE INSTALLATION �� m DIFFUSER THE 4" REQUIREMENT FOR SMOKE DETECTORS HAS INSTRUCTIONS FOR PROPER TERMINATIONS. TOP OF LENS FOR 110CD STROBES WITHIN 16' OF THE PILLOW BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 �� 2. 177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24" * USE WITH RETROFIT OR HIGH CURRENT MODULE w (610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER 4 \ 3' (MIN) 4" NOTE: MEASUREMENTS o .. SHOWN ARE TO THE REFERENCE El a INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. (102mm) CLOSEST EDGE OF THE MODEL NUMBER OHMS 1ST BAND 2ND BAND 3RD BAND 4TH BAND 5TH BAND WATTS CIRCUIT TYPE FIRE ALARM PANEL/MODULE \II (914mm MIN) CEILING DETECTOR. Lu V/11//�//// / / _/ . // / / / / / / ' //// Nil \\\\\ / / / ///////i///////////////////////// ///////41 4081-9001 733-892 2.2K RED RED RED GOLD N/A 1/2 ANNUNCIATOR (4300) 4004, 4010 (TROUBLE) � 5� -€ * 4006, I 4„ + N.O. INITIATING 4004*, 4004R, 4005*, 11:3moo" x CEILING MOUNTED - PULL, SMOKE, HEAT, 4100, 4120, 4100U, ZAM'SIsoo0,o FOR CEILING HEIGHTS LESS THAN 86" (2180mm), NFPA 72 AUDIBLE APPLIANCE 4a� O o THE VISUAL LENS MOUNTING HEIGHT SHALL BE 6" MIN (152.4mm MIN) SMOKE/HEAT / (102mm) 12" 081-9002 733-893 3.3K ORANGE ORANGE RED GOLD N/A 1 WATERFLOW, TAMPER, ETC. cti 00 wooco WITHIN 6" 150mm OF THE CEILING. AUDIBLE ONLY DETECTOR (MAX)( ) 24 PT. I/O SWITCH SUPV. 4605-7401, 4100 SERIES E 3 owl 0 ( ) BELOW FINISHED CEILING (305mm MAX) v) • w�� N liZ1 HEAT DETECTORS CURRENT LIMITED N.O. INITIATING 4090-9001 IDNET IAM (EOLR) V)W o l 90" MIN (2286mm MIN) - 4081-9003 733-896 4.7K YELLOW VIOLET RED GOLD N/A 1/2 �,o� 1LP 'i ® J ACCEPTED HERE NEVER HERE "' a NOTIFICATION (DACT) 2080-9024 cc up W> ABOVE FINISHED FLOOR OTHER MOUNTING HEIGHTS SHALL BE Cl) N.O. INITIATING 4004, 4005 m o �J� - ` � ( 1 4081-9004 733-886 6.8K BLUE GREY RED GOLD N/A 1/2 PULL, SMOKE, HEAT, 4090-9001 IDNET IAM N PERMITTED BY THE AHJ PROVIDING IT WATERFLOW, TAMPER, ETC. 2190-9173 MAPNETII 2 PT I/O 2 4-20MA ZAM (TROUBLE) AUDIBLE/VISUAL MEETS THE SOUND LEVEL OUTPUT REQUIRED.) a & VISUAL ONLY WALL MOUNTED CURRENT LIMITED N.O. INITIATING .3 APPLIANCES TO EXIT DOOR SMOKE/HEAT ( 4081-9005 733-984 1.8K BROWN GREY RED GOLD N/A 1/2 4090-9001 IDNET IAM 5' (MAX.) DETECTOR (IN LINE) N (1524mm) 4081-9006 733-890 560 Q GREEN BLUE BROWN GOLD N/A 1 N.C. INITIATING (EOLR) 4005*, 4090-9001 IDNET IAM SYNCHRONIZE MORE THAN DOOR 4100, 4100U TWO APPLIANCES IN ANY WIDTH 4081-9007 733-891 1.2K BROWN RED RED GOLD N/A 1 N.C. INITIATING (EOLR) 4005 FIELD OF VIEW. LESS 3' (76mm)'i 4081-9008 733-894 10K BROWN BLACK ORANGE GOLD N/A 1/2 NOTIFICATION 4004, 4005, 4006, 4008, 4009, 4010, 4100, 4100U 4081-9009 733-912 20 C RED BLACK BLACK GOLD N A 1 TO MR-101 RELAY COIL 4005 8 POINT I 0 L 96" MAX (NFPA, ADA) 5" SIDE WALL / / (2440mm MAX) (127mm) N.C. INITIATING (ACROSS CONTACTS) 4005*, 4090-9001 IDNET IAM REF. 80" MIN (IBC) ABOVE FINISHED FLOOR MANUAL 11, 4081-9010 733-973 1 K BROWN BLACK RED GOLD N/A 1 24 PT. I/O (ACROSS CONTACTS) 4605-7401, 4100 SERIESr. CURRENT LIMITED N.O. INITIATING (2032mm MIN) TO TOP OF LENS PULL (IN SERIES WITH CONTACT) 4090-9001 IDNET IAM STATI O N REF. 96" MAX (IBC) 80" MIN (ADA) (2032mm MIN) FIRE 4081-9011 733-974 100n BROWN BLACK BROWN GOLD N/A 1/2 ANNUNCIATOR (N2) 4006, 4008, 4010 (2440mm MAX) 80" MIN (NFPA) (2032mm MIN) PHONE / ;:f.: MAGNETIC 4081-9012 733-985 22K RED RED ORANGE GOLD N/A 1/2 SPEAKER CIRCUIT 4003 ABOVE FINISHED FLOOR JACK �® DOOR7 4081-9013 734-086 4.99K YELLOW WHITE WHITE BROWN BROWN 1/2 TO BOTTOM OF LENS Fy.L__ HOLDER - N.C. INITIATING ° Ed a� 0 FINISHED 4081-9014 734-092 2.4K RED YELLOW RED GOLD N/A 1/2 (SECURITY MONITORING EOLR) 4090-9001 IDNET IAM ® WALL CURRENT LIMITED N.O. INITIATING 13 NOTE: REFER TO THE PROPER DEVICE I 4081-9015 734-093 1.5K BROWN GREEN RED GOLD N/A 1/2 (SECURITY MONITORING EOLR) 4090-9001 IDNET IAM INSTALLATION INSTRUCTIONS 48" MAX (ADA) (1219mm) E FOR BACKBOX MOUNTING HEIGHT. • 48" MAX (NFPA, ADA) (1219mm MAX) I 4081-9016 734-149 150K BROWN GREEN YELLOW GOLD N/A 1/2 65 FINISHED 42" MIN (NFPA) (1067mm MIN) 4081-9017 734-171 3.9K ORANGE WHITE RED GOLD N/A 1 , -a FLOOR 4081-9018 734-168 10K BROWN BLACK ORANGE GOLD N/A 1 70VRMS CONSTANT SUPV. NACS 4100-1260 MEASUREMENTS SHOWN ARE I 378-090 8.2K GRAY RED RED GOLD N/A 1/2 SECURITY MONITORING (EOLR) 4100, 4100U T I \ I TO TOP OF PULL HANDLE 378-046 5.6K GREEN BLUE RED GOLD N/A 1/2 N.O. SECURITY MON. (SERIES) 4100, 4100U 378-069 12K BROWN RED ORANGE GOLD N/A 1/2 N.C. SECURITY MON. (SHUNT) 4100, 4100U 0 TrueAlertm NON—ADDRESSABLE MULTI—CANDELA AUDIBLE/VISIBLE NOTIFICATION APPLIANCE TrueAlert,' NON—ADDRESSABLE MULTI—CANDELA VISIBLE NOTIFICATION APPLIANCE PRODUCT INFORMATION PRODUCT INFORMATION N FEATURES: (CEILING MOUNT) FEATURES: (CEILING MOUNT) !� �' • CLASS B (STYLE Y) OPERATION REQUIRES CONNECTION • UL LISTED TO STANDARD 1971 ' (ERICO NO. 512) T-BAR r, t , WITH CLIPS AND SCREWS 0.0. TO A COMPATIBLE SMARTSYNC NAC OR TO •ADA COMPATIBLE v SUPPLIED BY CONTRACTOR m SMARTSYNC CONTROL MODULE (SCM) 4905-9938 SYNCHRONIZATION FLASH RATE MODE FOR USE WITH: 3 • CLASS A (STYLE Z) OPERATION WHEN CONNECTED TO THE • SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE . ' 3 4905-9938 SCM OR 4100 SERIES FIRE ALARM 4" SQUARE BOX, 1-1/2" DEEP FOR CLASS B OR CLASS A OPERATION / -4 HANDY BOX, 1-1/2" DEEP OR CONTROL PANEL NAC'S SINGLE GANG BOX, 2-1/2" DEEP OPTIONAL 4905-9928 ADAPTER PLATE. •SEPARATE SMARTSYNC CONTROL MODULES (SCMs) THAT PROVIDE SUPPLIED BY OTHERS REQUIRED FOR SURFACE CLASS B OR CLASS A OUTPUT FROM CONVENTIONAL NAC INPUTS t SPECIFICATIONS: MOUNTED ELECTRICAL BOX Ic SINGLE GANG BOX N • HOUSING DIMENSIONS (INCLUDING LENS) : 4-3/4"L X 6-7/8" W X 2-5/8"D o a c), (WIREMOLD V5744S) — _ SPECIFICATIONS: �� 2-1/4" (57mm) It • TEMPERATURE RANGE: 32' F TO 12T F (0' TO 50' C) alle • HOUSING DIMENSIONS: 4-3/4" L X 2-5/16" W X 2-5/8" D (121mm X 75mm X 67mm _ ) �bat* SUPPLIED BY OTHERS o • HUMIDITY RANGE: 10% TO 93% NON-CONDENSING AT 100' F (38' C) � ����� � __ II�I�,II� •TEMPERATURE RANGE: 32'F TO 122'F (0 TO 50'C)• TERMINAL BLOCKS FOR 18 AWG TO 12 AWG; TWO WIRES PER OPTIONAL 4905-9915/-9916 ADAPTER / i �_ii�i1 1 1� il • HUMIDITY RANGE: 10% TO 93% NON-CONDENSING AT 100'F (38'C) r TERMINAL FOR IN/OUT WIRING. �C , '� - __- - -� % i 4905-9910 ADAPTER PLATE, o — •TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER V I REQUIRED FOR SURFACE MOUNT TERMINAL FOR IN/OUT WIRING. OR WITH HANDY BOX UNLESS USING /WIRING TERMINALS ARE o o THE 49059926 WIRE GUARD STROBE ! LOCATED BEHIND HOUSING4 '_ / _ OPTIONAL 4905-9927 �i f' - RATED VOLTAGE RANGE: UL: 16 VDC TO 33 VDC PER UL 1971 o RED FIRE GUARD WIRING NOTES: (''► �. . __ _._.. - w L U. ULC: 20VDC TO 30VDC PER ULC S526-M878 I it,' 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL. II FI O R I� IIll a - FLASH RATE: 1Hz _ a STROBE INTENSITY VIEWING /A , II i .: — _ 2. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. DO NOT LOOP o - SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. WIRES UNDER TERMINALS. /► 1, Strobe ntensity �¢ — _ 3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER-LIMITED. 1 �� �i tA� viewingsiot WEs a3SirM INTENSITY SELECTION PLUG, 4. SEE INSTALLATION INSTRUCTIONS (579-548) FOR ADDITIONAL INFORMATION. , Intensity selection plug, i *CURRENT DRAWS REFLECT STROBE FLASHING AND HORN ON. ACCESSIBLE ONLY FROM REAR OF LENS ` i access ble only from rear of lenst f ' N HOUSING LETTERING STROBE RMS CURRENT @ HOUSING, FACTORY SETTING IS 75cd ; housing;factory setting is 15 cd v C,-o MODEL NUMBER COLOR COLOR RATING 16 VDC 18 VDC 24 VDC STROBE: to 4906-9128 RED WHITE 75cd 86 mA 76 mA 57 mA 0, 30cd 132 mA 117 mA 88 mA •• RATED VOLTAGE RANGE: UL LISTED: 16 VDC TO 33 VDC PER UL 1971 OPTIONAL 4905-9926 WIRE GUARD e o 75cd 250 mA 222 mA 167 mA ULC LISTED: 20 VDC TO 30 VDC PER ULC S526-M878 CEILING MOUNT WITH MOUNTING PLATE (/'� m CO 110cd 320 mA 284 mA 213 mA • FLASH RATE: 1Hz V J o 4906-9130 WHITE RED 75cd 86 mA 76 mA 57 mA •SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. c 30cd 132 mA 117 mA 88 mA FROM FACP 24VDC NON-CODED TO ADDITIONAL NOTIFICATION c) 75cd 250 mA 222 mA 167 mA NOTIFICATION APPLIANCE CIRCUIT + APPLIANCE DEVICE OR RETURN . �— TO FACP FOR STYLE Z APPLICATION N g 110cd 320 mA 284 mA 213 mA *CURRENT DRAWS REFLECT STROBE FLASHING OR PRECEDING DEVICE, OR z— x 5 IF LAST DEVICE ON CIRCUIT INA D 0 HOUSING LETTERING' STROBE RMS CURRENT © SIMPLEX 4905-9914, 9922, OR 1 + STYLE Y APPLICATION PLACE AN MODEL NUMBER COLOR COLOR RATING 16 VDC 18 VDC 24 VDC 9938 SYNC MODULE. I 1 1 END-OF LINE RESISTOR. (RESISTOR .14:C 0 Y c 4906-9102 RED WHITE 75cd 75 mA ' 67 mA 50 mA VALUE IS FACP DEPENDENT.) co HORN 3Ocd 125 mA 111 mA 83 mA N o - SOUND OUTPUT CHARACTERISTICS: 2400 TO 3700 Hz SWEEP, 75cd 233 mA 207 mA 155 mA �� I �\ �' I I ,� Q C� MODULATED AT 120 Hz RATE - 110cd 316 mA 281 mA 211 mA 0 0 BL.71 - �� CO U o �� o 1-----1,1------- 10 4906-9104 I WHITE I RED 7 5cd 75 mA 67 mA 50 mA z N c 30cd 125 mA 111 mA 83 mA LL H = I �I� 753150 Scd 233 mA 207 mA 155 mA HORN SOUND OUTPUT RATINGS ® 10 FT. (3m) �� ✓� 110cd 316 mA 281 mA 211 mA [ 0 1 [ 0 1 cKT+cKr- ' cKr+cKT- 0 VOLTAGE 16 VDC 24 VDC 33 VDC - - _ J r- SOUND TYPE o * STEADY CODED STEADY CODED STEADY CODED - - O CD z O cp REVERBERATE CHAMBER86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA ✓ UL 464 TEST �° � ° �' ---_Ji[�� ° ' Q (O Q -p ANECHOIC CHAMBER 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA --- ___ -- - __ END-OF-LINE L ctiFROM FACP 24VDC NOTIFICATION + RESISTOR (VALUE ^^ Z O -c * CODED VALUES ARE TYPICAL OF THE OUTPUT MEASURED WITH A TEMPORAL APPLIANCE CIRCUIT OR SIMPLEX $_ IS DEPENDENT 1..� CO o 0_ CODED OR A MARCH TIME CODED PULSE AND WITH A SOUND LEVEL METER 4905-9914, 9922 OR 9938 ~ `° _i SYNC MODULE OR PRECEDING DEVICE ON FACP) r I I 1 r I I m READING ON A "FAST" SETTING. UNDER THE SAME TEST CONDITIONS, CODED L L Li HORN OUTPUT "PEAK" SOUND LEVEL READINGS ARE TYPICALLY 4 dBA HIGHER. ' I__ - - L L E w �� / i JJ .5 m _. LL 3 O 5.8 dj N0 G 0 O N N 2 Q O 1-6 O A C O z ,o,^ °' co z I 7.C o N C LB . N 0 In 2 Q W E Qm co O 3 m H Cn 3 °> Q J Cl- c (3 5 Cl) W E m ci `o - = U S T) ci Q U 2 o Ti a. W (.fl I-- CV —N < m ti O E -1" 0 m W Y ti CC o r u) Q O CO 2 N m to T`-," a" O m m 0 I— DRAWN BY: J. JOHNSON E CHECKED BY: J. JOHNSON 1- ISSUE DATE: 6/15/17 J JOB#: 0 PROJECT#: 448:600370601 a 9 L SIMPLEXGRINNELL© 2017 E T SYSTEM: ` .2C FIRE ALARM SYSTEM . SHEET: _ z WIRING TYPICALS m EI 1_-o N O m O N 0 w E CO m L11 i- m L U U m N 2 FA-701 Z aNo X � c, o o_ ._ C) L