Loading...
Plans (37) BU P2017 - 00259 ERICKSON 8i. CARNEGIE 1. 1... 13 DUS .%JOHN 0 51 c..T...7 4.4c''1 6 D' ' 1 S, e'':--3. sAI HEL NS, IR , RECEIVED „..,/, � 5865 SEP 26 zo» th OF 0- 4 TIGARDOREGON CIT '+Or±TriRD ! BUILDII G DI�'ISIO ERICKSON & CARNEGIE, LLP TENANT 7300 SW HUNZIKER RD, SUITE 102 PROJECT DESCRIPTION u, TIGARD, OR 97223 PROJECT CONSISTS OF 990 SQ. FT. TENANT IMPROVEMENT TO EXISTING SUITE WITHIN z L HILLTOP BUSINESS CENTER. SUITE IS ON THE FIRST FLOOR OF A TWO STORY BUILDING. m m NEW PARTITION WALLS TO CREATE A RECEPTION, PRIVATE OFFICES AND A STORAGE ROOM. ``, CrIx LO ALL UPDATES TO COMPLY WITH OSSC CHAPTER 11 ACCESSIBILITY AND ANSI REQUIREMENTS. °- ROBINSON CONSTRUCTION CONTRACTOR Wa F. csi CV DEFERRED SUBMITTALS 21360 NW AMBERWOOD DR CONTACT: RYAN ROBINSON � '1 — CNI HILLSBORO, OR 97124 : ELECTRICAL N o Cr) COB .63147 <n c— n • PLUMBING TELEPHONE: 503,645.8531 FAX: 503.645.5357 LEGAL DESCRIPTION CIDA, INC. ARCHITECT TAX ID NUMBER: 2S101DB00100 15895 SW 72ND AVE, SUITE 200 CONTACT: JEN HAWKINS PORTLAND, OREGON 97224 (T): (503) 226- 1285 BUILDING CODE INFORMATION (F): (503) 226- 1670 DESIGN CODE: 2014 OREGON STRUCTURAL SPECIALTY CODE (OSSC) al , OCCUPANCY: B f CONSTRUCTION TYPE: V-B (NON-SPRINKLERED) LI OSSC 1004 OCCUPANT LOAD TABLE BUILDING AREA: ARCHITECTURE 1ST FLOOR: 5,056 SF (SUITE 102 ONLY IN SCOPE) I= E N G I NI E E RT I NR G 2ND FLOOR: 5,186 SF (NOT IN SCOPE) ROOM f NAME OCCUPANCY TYPE LOADING FACTOR AREA LOAD TOTAL BUILDING AREA: 10,242 SF PLANNING PORTABLE FIRE EXTINGUISHERS, (O 9Q6); li) INTERIORS 100 RECEPTION BUSINESS 100 190 2 PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN OCCUPANCIES AND LOCATIONS AS 101 OFFICE BUSINESS 100 235 2 REQUIRED BY THE OREGON FIRE CODE AND THE FIRE MARSHALL LANDSCAPE 102 (E) CLOSET BUSINESS 300 5 0 15895 SW 72ND AVE SUITE 200 103 SNACK BAR BUSINESS 100 71 1 MEANS OF EGRESS ILLUMINATION (OSSC 1006): PORTLAND, OREGON 9722 4 104 OPEN OFFICE BUSINESS 100 152 2 ILLUMINATION LEVEL (OSSC 1006.2): T E L : 5 0 3 . 2 2 6 . 1 2 8 5 105 OFFICE BUSINESS 100 213 2 MINIMUM 1 FOOT-CANDLE AT THE WALKING SURFACE LEVEL F A x : 5 0 a . 2 2 s . 1 6 7 0 106 STORAGE BUSINESS _ 300 58 0 ILLUMINATION EMERGENCY POWER (OSSC 1006.3): V W w . C I D A I N C . C 0 hi 107 (E) EXIT BUSINESS 100 66 1 EMERGENCY POWER SHALL BE PROVIDED FOR A DURATION OF 90-MINUTES MINIMUM AREAS REQUIRED TO BE ILLUMINATED BY EMERGENCY POWER CITY OF TIGARD TOTAL FOR OCCUPANT LOAD 990 9 - CORRIDORS AND EXIT PASSAGEWAYS ' REVILWLD FOR CODE COMPLIANCE - INTERIOR EXIT DISCHARGE ELEMENTS - EXTERIOR LANDINGS Approved: [ OTC: [1.--1 1 C'� 10 rya l�} EMERGENCY POWER PERFORMANCE (OSSC 1006.4): Permit it ° . )` -,C3 r,. , MINIMUM 1 FOOT-CANDLE AT THE WALKING SURFACE LEVEL Address: -5r'I Ti l I •I, l• IL EMERGENCY POWER (OSSC 1006.3): Suite#: a INITIAL ILLUMINATION: *� 1 FOOT-CANDLE AVERAGE W/ 0.1 FOOT-CANDLE MINIMUM AT ANY POINT AT FLOOR By: !►i, Date: '6'- (T J LEVEL r J 0 END OF EMERGENCY LIGHTING PERIOD: 0.6 FOOT-CANDLE AVERAGE W/ 0.06 FOOT-CANDLE MINIMUM AT ANY POINT AT FLOOR w LEVEL OFFICE COPY W CJT SIGNS (OSSC 1011); 0 — SEE 2/11.1 FOR LOCATIONS OF EXIT SIGNAGE O uj Go PiILLUMINATION (OSSC 1011.2): L EXIT SIGNS ARE REQUIRED TO BE INTERNALLY OR EXTERNALLY ILLUMINATED Z riCOMMON PATH OF EGRESS TRAVEL (OSSC 1014): _�, _,_ _ , L • O 0) COMMON PATH OF EGRESS TRAVEL (1014.1) / W NON-SPRINKLERED BUILDING, B OCCUPANCY > ICS LY_ MAX TRAVEL DISTANCE ALLOWED ="100' - SUITE 102: 0W Q �. y .. ACTUAL TRAVEL DISTANCE = 73'-1" _ AREA OF WORK g,,. f. .y , w<' .�.. .. . . �, _ EXIT ACCESS TRAVEL DISTANCE (OSSC 1016);. 0 / 990 ti7Q.FT. � � � a 1 ._ N 1 PATH OF EXIT TRAVEL (1016.1) - 0 Z Z Ce N ! :, .. NON-SPRINKLERED BUILDING, B OCCUPANCY r r= • a Pr harry-rpriiA 41r + �• , _ - y ..7. w RELEASES MAX TRAVEL DISTANCE ALLOWED, = 200 -0 W Z ` '` "`I " a a ACTUAL TRAVEL DISTANCE = 84 -10 E- 0 I— ¢ C, ; — linglial �# EGR1 EXIT REQUIRED(TABLE iQ2f.2) tn I 2 EXIT PROVIDED CD ,-.7i, . co r.'co II) a 1"e) C`,/ .- - ' .{ y y: . ' \\\N\ \VN\` COVER SHEET EGRESS WIDTH REQUIRED (TABLE 1005.1) 0 Q • • CS1 COVER SHEET EGRESS WIDTH REQUIRED (11 x .2) = 2.2" - o N) . , Ig EGRESS WIDTH PROVIDED = 36" MIN. PROVIDED _ IE r'`,. 140: ' '•rl a"�`rare ,. '► ACCESSIBILITY (OSSC CHAPTER 11 AND ASI CHAPTER 5): E SEE FLOOR PLANS FOR REQUIRED CLEARANCES AT DOORS, �_, iou t . .� \ \� ARCHITECTURAL SAND FIXTURES : IL SEE INTERIOR ELEVATIONS FOR REQUIRED CLEARANCES AT CABINET �' • • T1.1 FIRST FLOOR PLAN, RCP & DETAILS SEE DETAILS AND INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS f' k ----;-,..r,--,-,-;-:,------ e'•J Yl'X.'-'"v- e ' o- .. • • T1.2 FINISH FLOOR PLAN & SCHEDULE ALL SIGNAGE GRAPHICS, LOCATION AND MOUNTING TO COMPLY WITH OSSC CHAPTER 11 :„..LI:K\__ • • 11.3 DOOR SCHEDULE, ELEVATIONS & DETAILS • PLUMBING SYSTEMS (TABLE 2902.1): a �'` *ALL EXISTING COMMON PLUMBING FIXTURES TO REMAIN. NO CHANGE OF OCCUPANCY/USE. - 1n r u r • -.s. .i `� u :. . -. _ i-.. ��� — _ _ .1. . . . _ - . COVER SHEET TM C Si 4 9 VICINITY MAP4 12 FIRST FLOOR EGRESS PLAN ���r�Y Ur 1�l�►l�D CS NO SCALE Approved b Planning Date: l 7"''6 i �� CS 1/16"=1'-a" (FOR REFERENCE ONLY) JOB NO. 170137.01 ©2017 c P C/ODA AIL Mtn RfSERI D Initials; ............0-0.-- V V 15'-8 3/4"± 0 0.>\ViDi /1- ../.> C I II II L ,� U II JJ i,Cr4IN JQH SON --&--1). (E)100-A I w -,,. .. /t4"..., • �f�,SAINT HEL NS, OR ,�'� 1� 5865 18GA. STUD BRACE TO UNDERSIDE III RECEPTION OF 0.° 0 - IlillrAl REC yITION r � r /� /� - , OF STRUCTURE AT 6'-0" O.C. 100 : � - no I //I I / I I / I \ s`- I I / II I{ / I- ) SUSPENDED CEILING +iI IA I/ { i/ I I {/ I CONT. TOP TRACK- ATTACH TO i �- JJ L = J -J NUM 1111111•1CEILING GRID W/ 1" TYPE "S" (E)CLOSET OFFICE O O `r' E CLOSET OFFICE " r� SCREWS AT 2 -0 O.C. AND TO TOP 102 101 0 , , 102 101 �4 PLATE OF PARTITION W/ (2) 1" _ _ TYPE 'S' SCREWS - TRIM PANEL AS A L I VS �f ■ ' i REQUIRED i i __ O '`�� I �J ii r r FULL THICK SOUND ATTENUATION v' �8� I /I I /I I /I c5 BATT �- A w i i I- - - -I \--O_.__.<i: 1 T1.3 1 1 r { / I I / I {- / { w Q cn I I o O �� ��TMP. I / II I I / { II / II METAL STUD PARTITION PER PLAN 20 diI I I��I 1 J �' c, w © I i BASE BOTTOM TRACK TO FLOOR WITH N N I ANCHORS AT 4'-0" O.C. (MAX) AND SNACK BAR SNA BiR 1- c\J CV 0 0 AT CORNERS AND ENDS a 103 OPEN OFFICE I o 11 I OPEN OFFICE - 0 `n co i - 4.3 104 1 ` _ 104-I r \ .1 W o o)S \moi I / _ CV l / _I I I I I I 1/4 - J (E) HALLWAY .(E) HALLWAY' w •lliK I I - 107 I I 107. , ,�111 4 TYP. INTERIOR PARTITION- TYPE A (E)107-A 1 O Q 1 MIME • . III i�� -11 - - - T1.1 3/4" = 1'-0" 092900-03 FI o N �. . :. . II ,, II \____.. (0 ___A (0) I r-/�� IN 12 GA. HANGER WIRES 4'-0" II / II O.C. (TYP.) OFFICE = / ■ OFFICE = COMPRESSION BRACE, SEE SCHEDULE 105 / 105 - -_- / 12 GA. SPLAYED BRACE WIRES cHI EH ' `I Al (TYP.) MAXIMUM ANGLE FROM A I I I I ■/I ��1 - HORIZONTAL IS 45 DEGREES1 el - � - I { � _ �`,�11 � CROSS TEE STORAGE STORAGE II / I61 I I ��� ! .tir „ 106 --- - 1 Q6 / _ ,1 - \ �� MAIN TEE ARCHITECTURE <,). .\''‘ ; �� II , IIII ENGINEERING 0 0 i ,/ PLANNING _ � • • • • • INTERIORS �� _Cv3 _ FOF C _ \ /\ / % - C - f / i- LANDSCAPE p` V V �_ __ FASTENER SCHEDULE TE 200 5'-11 1/2"± 6'_2" 9'_g' CONSTRUCTION TYPE FASTENER REQUIREMENTS PORTLAND,0 15895 SW 2 OREGON ND AVE ul97224 , / - WOOD 1/4" X 3" SCREW EYES TEL : 5 0 3 . 2 2 6 . 1 2 8 5 _____)- STEEL DECK PRE DROP WIRES, CMI DC1 OR DC, 2-1/4" METEAL DECK FAX : 5 0 3 . 2 2 6 . 1 s o WWW . CIDAINC . COM SCREW EYES POST TENSIONED CONCRETE PRE DROP WIRES, EMBEDS, 1/4" X 3/4" METAL HIT ANCHORS T S if - CAST IN PLACE CONCRETE ; PRE DROP WIRES, EMBEDS, 1/4" X 3/4" METAL HIT ANCHORS NORTH NORTH COMPRESSION STRUT SCHEDULE 4 1 FIRST FLOOR PLAN 2 FIRST FLOOR REFLECTED CEILING PLAN MAX. LENGTH OF STRUT STRUT REQUIREMENTS T1.1 1/4" = 1'-0" III T1.1 1/4" = 1'-0" 5'-10" 1/2' DIA. CONDUIT (EMT) 7'-8" 3/4" DIA. CONDUIT (EMT) 9'-9" 1" DIA. CONDUIT (EMT) am 12'-0" SINGLE 1-5/8" X 20 GA METAL STUD 15'-0" BACK TO BACK 1-5/8" X 20 GA METAL STUDS all N 13'-6" SINGLE 2-1/2" X 20 GA METAL STUD NJ 0 15'-0" BACK TO BACK 2-1/2" X 20 GA METAL STUDS w FLOOR PLAN LEGEND RCP GENERAL NOTES RCP LEGEND PROVIDE HEAVY DUTY CEILING SUSPENSION SYSTEM CONFORMING TO THE REQUIREMENTS OPF III 0 =MINN W ASTM C-635-00. ma � (E) EXTERIOR WALLLIGHTING INDICATED ON THIS PLAN IS FOR DESIGN INTENT ONLY AND ROOM ROOM NAME & NUMBER M 1. D 101 - / INT. OR EXT. WALL ROOF OR FLOOR DECK IS CONSIDERED A DELEGATED DESIGN SYSTEM. THE CONTRACTOR IS V f NOTE: N (N) INTERIOR PARTITION RESPONSIBLE FOR DESIGNING A FINISHED INTERIOR LIGHTING LAYOUT i SUSPENDED CEILINGS TO BE Z a* N THAT COMPLIES WITH RECOMMENDED LIGHTING LEVELS PUBLISHED IN Q U u " INSTALLED WITH BERC2 I'"' %/7///%ai (E) DEMISING PARTITION TO REMAIN Z CI N THE CURRENT IES LIGHTING HANDBOOK FOR THE FUNCTION OF (E) 2x2 ACOUSTICAL CEILING TILE- PATCH AS SYSTEM BY ARMSTRONG AS W CC ct 0) (E) PARTITON TO REMAIN SPACES INDICATED. CONTRACTOR SHALL SUBMIT A PHOTOMETRIC REQUIRED FOR 'LIKE NEW' APPEARANCE-- DUCT SHOWN, APPROVED EQUAL M STUDY WITH COMPLETED ENERGY CODE FORMS INDICATING CODE CLIP SYSTEM OR PRESCRIPTIVE Lai (E) EXISTING SEE DETAIL 12/T1.1 NOTE 10 > w o COMPLIANCE AS WELL AS PROPOSED LIGHTING LAYOUT WITH _ TMP METHOD PER OSSC 803.9.1.1 W0 FOF FACE OF FINISH ASSOCIATED PRODUCT CUT SHEETS FOR ARCHITECT APPROVAL. < C AND ASTM 635 & 636 Cr 2. JUNCTION BOXES TO BE PAINTED TO MATCH ADJACENT SURFACE. NOTE 3 r/ NOTE 4 OTE 5 I -NOTE 9 I M N FLOOR PLAN KEYNOTES CD 3. VERIFY ALL BUILDING SHELL CONDITIONS - REPORT ANY CONFLICTS OR f NOTE 6 Z OtgZ Et ADVERSE CONDITIONS TO ARCHITECT PRIOR TO START OF WORK (E) GYP. BOARD CEILING NOTE: Q D Q 0 ALIGN NEW WALL WITH EXISTING. ALL WIRE TO BE NO. 12 z Z = 4. ELECTRICAL CONTRACTOR TO VERIFY MINIMUM EMERGENCY EXIT GAUGE. CONNECTIONS TO BE W © INSTA HOT- TENANT PROVIDED/ CONTRACTOR INSTALLED. ILLUMINATION WITH BATTERY BACK-UP AT EGRESS PATH OF TRAVEL. - - - - NOTE 1 NOTE 11,12 3 TURN MINIMUM WITHIN 3 F- O I-- PROVIDE 1 F.C. MIN. EMERGENCY LIGHTING AT PATH OF TRAVEL. THIS �\ - - �-I NOTE 2 INCHES OF THE CONNECTION © MICROWAVE- PROVIDE DESIGNATED OUTLET. TENANT PROVIDED LEVEL MAY NOT DIMINISH TO LESS THAN .06 F.C. OVER 1.5 HOURS OF II II 2X4 DIRECT/INDIRECT LAY-IN LED LIGHT NOTE 7 ` NOTE 7 (1) V) OPERATION TO BE DEMOLISHED- SALVAGE/RE-USE IF " l I i-_-_-_- FEASIBLE I le 5. CONTRACTOR TO PATCH ABOVE DEMO WALLS AND AT RELOCATION OF NOTE 8 0 LIGHTS AS NECESSARY, REPLACE YELLOW OR DAMAGED TILES. NOTES: 0 M FLOOR PLAN GENERAL NOTES 6. WHEN POSSIBLE, USE SALVAGED LIGHTING FIXTURES. LOCATE LEGHT) X4 DREMAININDIRECT LAY-IN LED 1. 7/8" WALL MOLDING. ATTACH TO PERIMETER WALLS ACCORDING TO 2/T1.1 2. 2 BERG (BEAM END RETAINING CLIP) AT INTERSECTION OF EACH GRID BAR TO WALL SUPPORT. ATTACH BERG TO GRID ON 2 ADJACENT CC N -V\-WALLS. PROVIDE 1/2" CLEARANCE ON UNATTACHED BERC. 1. ALL CONDITIONS SHOWN OR IMPLIED ON THE DRAWINGS SHALL BE , 3. PERIMETER HANGER WIRES - WITHIN 8" OF ALL WALL ON ALL TERMINAL ENDS OF CROSS RUNNERS AND MAIN RUNNERS. VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. NOTIFY (E) 2X4 DIRECT/INDIRECT LAY-IN LEDLIGHT CONNECTED TO EMERGENCY POWER 4• SUSPENSION WIRES AT 4'-0" ON CENTER. SOFT ANNEALED GALVANIZED " ARCHITECT / ENGINEER OF ANY DISCREPANCIES PRIOR TO THE START SUPPLY TO REMAIN 5. VERTICAL STRUT FASTENED TO MAIN RUNNER AND EXTENDED TO THE STRUCTURAL FRAME. 121-0" O.C. EACH WAY OF WORK. 6. HORIZONTAL RESTRAINTS SECURED TO MAIN RUNNER WITHIN 2" OF CROSS RUNNER. INSTALL 4 AT 90' ANGLE FROM EACH OTHER AND AT NEW 2X4 DIRECT/INDIRECT LAY-IN LED ANGLE LESS THAN 45' FROM THE PLANE OF THE CEILING. 2. ALL DIMENSIONS ARE TO CENTER LINE OF WALL UNLESS NOTED LIGHT TO MATCH EXISTING 7. HEAVY DUTY SUSPENDED CEILING SYSTEM - MAIN RUNNERS AND CROSS RUNNERS OTHERWISE. .. 8. ACOUSTICAL CEILING PANELS - 24" X 48" X 5/8" LAY-IN. (24" X 24" WHERE INDICATED ON PLANS) 3. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED AND INSTALLED AS9. TRAPEZE DUCTWORK AND OTHER LARGE OBSTRUCTIONS, COUNTER SLOPE. NEW 2X4 DIRECT/INDIRECT LAY-IN LED 10. CONNECTION DEVICE TO HAVE 180# CAPACITY. REQUIRED BY APPLICABLE STANDARDS. RELOCATE AS NEEDED. E----4‘414--/- LIGHT CONNECTED TO EMERGENCY POWER SUPPLY TO MATCH EXISTING 11. LIGHT FIXTURES MUST BE ATTACHED TO SUSPENSION SYSTEM. FIXTURES WEIGHING LESS THAN 561bs MUST HAVE (2) 12-GAUGE WIRES FIRST FLOOR PLAN, RCP AT DIAGONAL CORNERS. HEAVIER FIXTURES MUST BE SUPPORTED INDEPENDANTLY FROM THE BUILDING STRUCTURE. PENDANT LIGHTS MUST & DETAILS WALL TYPES FIRE EXTINGUISHER CABINET -- VERIFY 12. MECHBE ORTED ANICALDIRECTLY FROM DEVICES MUST BEEATTACHED STRUCTURE TO MITH A 9-GAUGE AIN BEAMS AND CIRE ROSSETEESLESS OF DEVICES WEIGHT. WEIGHING LESS THAN 2OIbs DO NOT REQUIRE LOCATION WITH FIRE MARSHALL SAFETY WIRES. DEVICES WEIGHING 20-56Ibs REQUIRE (2) 12-GAUGE WIRES AT DIAGONAL CORNERS. HEAVIER FIXTURES MUST BE T1.1 - NEW INTERIOR PARTITION - NON-LOAD BEARING A �1. 362S162-33 METAL STUDS, 24" O.C. TO UNDERSIDE EGRESS PATH OF TRAVEL SUPPORTED INDEPENDANTLY FROM THE BUILDING STRUCTURE. OF CEILING WITH (1) LAYER OF 5/8" GYP. BOARD EACH SIDE - PROVIDE GLASS OR MINERAL FIBER o E ILLUMINATED EXIT SIGN -- DIRECTIONAL AS 12 LATERAL BRACING FOR HEAVY-DUTY SUSPENDED CEILINGJOB N0. 170137.01 INDICATED ON PLANS INSULATION FULL DEPTH OF CAVITY. SEE 4/T1.1 T1.1 3/4" = 1'-0" 095123-01 CLIP ©2017 ODAP.C./CIDA ALL RIGHTS RESERVED DOOR SCHEDULE il'-i" V`- DOOR # DOOR HARDWARE OPENING WIDTH DOOR DOOR DOOR FRAME FRAME NOTES DOOR # A '`" MELAMINE ALL INTERIOR SURFACES TYP. TYPE GROUP x HEIGHT THICKNESS MATERIAL FINISH MATERIAL FINISH � (E)100 -- -- -- -- (E)100 i PLASTIC LAMINATE AT ALL EXPOSED �' -- -- -- -- -- !� } EXTERIOR SURFACES TYP. 1 STIN X10 SON 101-A A 1 3'-0"x7'-0" 1 3/4" SC STAINED HMKD PREFINISHED -- 101-A r WIRE PULLS - LOCATE 1-1/2" FROM Q; y' VERTICAL EDGE (TYP.) • , ( • (E)102-A -- -- -- -- -- -- -- -- -- (E)102-A OUTLET - f'�J SAINT HELENS, ; OR 105 A 1 3'-0"x7'-0" 1 3/4" SC STAINED HMKD PREFINISHED -- 105 - 1 5865 w �, 106 A 2 3'-0"x71-0" 1 3/4" SC STAINED HMKD PREFINISHED -- 106 PLASTIC LAMINATE AT ALL EXPOSED OF EXTERIOR SURFACES TYP. (E)107-A -- -- -- -- -- (E)107-A NOTES: I Ida WIRE PULLS - LOCATE 1 ELEVATION KEYNOTES 1'-6" / FROM VERTICAL EDGE (TYP )/2„ HARDWARE SCHEDULE _ PLASTIC LAMINATE COUNTER TOP W/ 4" OFFICE TYPE 1 STOREROOM TYPE 2 © O PAINTED GYP BOARD PER SCHEDULE o SIDE AND BACKSPLASH, FLAT EDGE, TYP. COI.3 © RUBBER BASE PER SCHEDULE `v 2'-1" 2EQ (45'-3" , 1" / PROVIDE BLOCKING AS REQUIRED 1 1 2 PAIR BUTTS 1 1 2 PAIR BUTTS © PL-1 PLASTIC LAMINATE CABINETS WITH / / ADJUSTABLE SHELVING WHERE SHOWN - ON ALL VISIBLE SIDES • f 01) I��t f �.L‘r MELAMINE AT ALL CABINET cn 1 EA OFFICE LOCKSET 1 EA STOREROOM LOCKSET < \ �,L �. 0 PL-2 PLASTIC LAMINATE COUNTERTOP _ - - - -- ; �C INTERIORS TYP. O WITH 4" BACKSPLASH WHERE SHOWN _ _ J PLASTIC LAMINATE AT ALL I �1 ® VERT. z N 1 SET GASKETS 1 SET SILENCERS I \ %- WI 0 SINK- SINGLE BOWL : 1- EXTERIOR SURFACES TYP. : m 1 EA WALL STOP 1 EA WALL STOP K 8> 0 TENANT-PROVIDED MICROWAVE - o SHELF PIN HOLES © 1" O.C. TYP. LU a CONTRACTOR TO PROVIDE POWER, VERIFY j d- ,, W/ ADJ. PLASTIC LAMINATE SHELF 1 EA CLOSER I SIZE W/TENANT PRIOR TO FABRICAITON I N N. 1,- - - - ' 411110AND ADJUST CABINET SIZE ACCORDINGLY r w 3 3 .7 j (-8) TENANT-PROVIDED MICROWAVE - BASE PER SCHEDULE Q \ \ ABBREVIATIONS: N \ / I © CONTRACTOR TO PROVIDE POWER, VERIFY SIZE W/TENANT PRIOR TO FABRICAITON \ o (E) EXISTING -2 , 1" AND ADJUST CABINET SIZE ACCORDINGLY ' 03 0 0 SC SOLID CORE HMKD HOLLOW METAL KNOCK DOWN / 2EQ@5 K9) EDGE OF WALL /3 4, . N 3 SNACK BAR 103 ELEVATION 4 CABINET SECTION AT MICROWAVE GENERAL NOTES: 11.3 1/4" = 1'-0" T1.3 3/4" = 1'-0" 064023-04 ALL NEW DOORS TO MATCH EXISTING, SPECIES, STAIN, FINISH, & HARDWARE. THE OPENING FORCE SHALL NOT EXCEED 5 LBS FOR INTERIOR DOORS, 8.5 LBS FOR EXTERIOR DOORS, AND THE MINIMUM FORCE REQUIRED TO ______V\_ CLOSE AND LATCH THE DOOR FOR FIRE DOORS. OSSC 1109.9.9 ALL HARDWARE SHALL COMPLY WITH THE REQUIREMENTS OF THE ADA. PLASTIC LAMINATE AT ALL EXPOSED DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. EXTERIOR SURFACES TYP. CENTERLINE OF STUD WALL AND CONTRACTOR TO VERIFY HARDWARE FUNCTION FOR ALL DOORS WITH TENANT PRIOR TO ORDER/INSTALL. SHELF PIN HOLES 1" O.C. TYP. W/ ADJ. CENTERLINE OF MULLION o PLASTIC LAMINATE SHELVES "' WIRE PULLS - LOCATE 1-1/2" FROM MEULLION ALUMINUM) STOREFRONT SYSTEM VERTICAL EDGE (TYP.) MELAMINE ALL INTERIOR SURFACES TYP. (E)INSULATED GLAZING , _ _,,— 61 ARCHITECTURE _, PLASTIC LAMINATE COUNTER TOP W/ 4" LJSAAL AC OVER NEOPRENE GASKET-- ENGINEERING 1, 1'-1" / SIDE AND BACKSPLASH, FLAT EDGE, TYP. ! ATTACH EATO STOREFRONT SYSTEM W/ ADHESIVE TAPE PLANNING U 12 o SINK INTERIORS 1r1 1/2" LANDSCAPE OIl. N 2 -1PROVIDE BLOCKING AS REQUIRED„W //1 -6/i2 ` ,, 1 5895 SW 72ND AVE SUITE 200 / __ ` \ �� N PORTLAND, OREGON 97224 \ /� c TEMPERED GLASS ( TEL : 5 0 3 . 2 2 6 . 1 285 \ / • i'... FAX : 5 0 3 . 2 2 6 . 1 6 7 0 \ / ✓ r W W W C I D A I N C C O M C PLASTIC LAMINATE AT ALL EXPOSED \ /OR PER z = I EXTERIOR SURFACES TYP. PREFINISHED 16 GAUGE SHEET >, RHEDULE (...) METAL CHANNEL-- COLOR TO J 0 0 MELAMINE AT ALL INTERIOR SURFACES TYP. / \ T Q o MATCH WINDOW SYSTEM / \ 12 N ` / \ 11 / - \ T1.3 FINISH Fl OOR N, // T1.3 FINISH FLOOR -0 \ BASE PER SCHEDULE GYP. BD. WALL PER PLAN FLUSH FULL RELITE �- i — a A t J o 5 DOOR TYPES 6 RELITE SCHEDULE & TYPES T1.3 1/4” = ,'-o" T1.3 1/4" = 1'-0" 7 CABINET SECTION AT SINK 8 TYPICAL INTERIOR WALL @ STOREFRONT MULLION •• 1-1-1 T13 3/4" = 1'-0" 064023-04 T1.3 3" = 1'-0" 08400-03 L 0 --D o W 0 N ". Z z CC 04 W ,, v\_____.7._ L., < Ct W • W 0 • d - • METAL STUDS-- SEE WALL TYPES R 0 m N -Il U- -- - : .6 Z 0 Z ct z a W Z I 0 . .;; I- 0 I— GYPSUM BOARD (0 l� �( LLiui GYP. BD. O ______,14...____ 110 0 O STEEL STUD WALL(DOUBLE STUDS M HEAD CONDRION AT ALL JAMBS) RELITE FRAME BEYOND IE la HOLLOW METAL JAMB HAD CONDITION METAL RELITE FRAME imigicimmissiiimmissomisinamL/ I L. METAL GLASS STOP-- PAINT TO 11111111 lli SOLID CORE DOOR - SEE DOOR II �4 MATCH FRAME SCHEDULE < 'tom — - �� DOOR SCHEDULE, �— TEMPERED GLASS ELEVATION & DETAILS JAMB CONDITION JAMB CONDITION rl.3 11 TYPICAL INTERIOR DOOR DETAIL C2) TYPICAL INTERIOR RELITE JOB NO. 170137.01 T1.3 3" = 1'-0" 3" = 1'-0" ©2017 CIDA, P.C./ODA ALL RIGHTS RESERVED `C FINISH FLOOR PLAN LEGEND ROOM FINISH SCHEDULE 19 I II II CORRIDOR ROOM NAME & NUMBER ROOM # ROOM NAME FLOOR BASE N WALL E WALL S WALL W WALL CEILING HEIGHT NOTES �WD >- 100 100 RECEPTION CPT-1 B-1 W-1 W-1 W-1 W-1 CL-1 (E) • • 101 OFFICE CPT-1 B-1 W-1 W-1 W-1 W-1 CL-1 (E) W DUSTIN JOHNSON . Q • a — 103 SNACK BAR VCT-1 B 1 W 1 W 1 W 1 W 1 CL 1 E INT HELENS, OR 102 (E) CLOSET CPT-1 B-1 W-1 W-1 W-1 W-1 CL-1 (E) " • RECEPTION: : � : . .. •. . I . : . - - - - - - ( ) -�J?,S " � . 0 I r' E Q - 5865 y • III 100 T"/ = 104 OFFICE CPT-1 B-1 W-1 W-1 W-1 W-1 CL-1 (E) 4) OF 0\)\e. • OFFICE VCT-1 105 OFFICE CPT-1 B-1 W-1 W-1 W-1 W-1 CL-1E • . . . • 10.1 .. . . . ( ) 106 STORAGE VCT-1 B-1 W-1 W-1 W-1 W-1 CL-1 (E) - - CL-2 (E) 107 (E) EXIT CPT-1 B-1 W-1 W-1 W-1 W 1 ç- ) �_ _ = FINISH FLOOR PLAN LEGEND LIST OF FINISHES J- „„, I t' y E)CL�SET .• FLOORS BASES WALLS CEILINGS CASEWORK O : • _ O CONTRACTOR TO PROVIDE METAL SCHLUTER, OR EQUAL, TRANSITION 1 STRIP BETWEEN FLOORING MATERIALS CPT-1 B-1 W-1 CL-1 PL-1 .. CARPET TILE, MOHAWK, 4" RUBBER BASE, PAINTED GYPSUM BOARD (E) 2x2 ACOUSTICAL PLASTIC LAMINATE BIGELOW, ICONIC EARTH, ROPPE, COLOR 174 FIELD PAINT, BENJAMIN MOORE, CEILING TILE VERTICAL SURFACES, NEVAMAR, �, • -0 ( 1 DRIFTED GROUND TILE SMOKE HISTORIC COLORS, REVERE ARMORED PROTECTION, BAILEY "' r FINISH FLOOR PLAN GENERAL NOTES 12BY36, COLOR CLASSIC PEWTER, HC-172 WK0027T, TEXTUREDcc 0 RIDGE 358, 12" X 36", z �' l t • BRICK ASHLAR INSTALL w m I 1. VERIFY ALL FINISH SELECTIONS WITH TENANT AND OWNER PRIOR TO VCT-1 CL-2 PL-2 f ,,, SNACK BAR • • ORDER/INSTALL. VINYL COMPOSITION TILE, (E) PAINTED GYP. BOARD PLASTIC LAMINATE a_ I 103 I • ARMSTRONG, STANDARD CEILING, BENJAMIN COUNTERTOPS/BACKSPLASH, \ 0 i OPEN OFFICE 2. HATCHES SHOWN FOR REPRESENTATIONAL PURPOSES ONLY. -- EXCELON, IMPERIAL MOORE, HISTORIC NEVAMAR, ARMORED '� '� 1:04 CONTRACTOR TO PROVIDE SHOP DRAWINGS INDICATING FLOORING TEXTURE, COLOR 51908 COLORS, REVERE PROTECTION, COOL CHIC E)-1-- ."'6.r- S I r MATERIAL PATTERNS, SEAMS AND TRANSITIONS FOR DESIGNER PEWTER, 12X12 PEWTER, HC-172 VA7002T, TEXTURED o APPROVAL. w rncNi 3. PATCH AND REPAIR ANY DAMAGES WHERE DEMOLITION HAS OCCURRED D 0 I I - FOR LIKE NEW APPEARANCE. cn - N in 4. ELECTRICAL OUTLETS TO BE ADDED/PROVIDED BY SUBCONTRACTOR TO EXIT' MEET ELECTRICAL CODE. CONTRACTOR TO VERIFY W/TENANT EXACT REQUIREMENTS AND LOCATIONS OF ELECTRICAL/DATA/PHONE OUTLETS. • TENANT RESPONSIBLE FOR CONTRACT FOR LOW VOLTAGE DESIGN AND INSTALLATION. 111111111\ . . .. . . . . . .. . 5. FURNITURE IS SHOWN FOR DIAGRAMMATIC PURPOSES ONLY AND IS TO �� BE PROVIDED BY OWNER. --� •OFFICE - I 1 I I 105. . " nnSTO A 1106 . . . ." " . . " No‘ nill - - _ I . 61 .. . -----. • 1 CO 1 iirrrii�iirr„arir/r2 . 1. Ns ARCHITECTURE ENGINEERING PLANNING \/N/ INTERIORS _ LANDSCAPE J . 15895 SW 72ND AVE SUITE 200 PORTLAND, OREGON 97224 TEL : 5 0 3 . 2 2 6 . 1 2 8 5 FAX : 5 0 3 . 2 2 6 . 1 6 7 0 W W W . C I D A I N C . C O M V NORTH * 1 FIRST FLOOR FINISH PLAN T1.2 1/4" = 1'-0" a. J N J o uI1.- 0 .- o W V) N Z CI N W CC ICC O) L.I < o 0 W o Y m N p Od 1- Z c Z Z Z z W 0 H I- CO X o 0 O M CC hW FINISH FLOOR PLAN, SCHEDULE T1.2 JOB NO. 170137.01 ©2017 CIDA, P.C./CIDA ALL RIGHTS RESERVED