Loading...
Plans (15) BU P2016 - 00224 , (..) DRAWING INDEX _ Ce SH 1.0 COVER SHEET I". SH1.1 NOTES — U SH 2.0 DEMO PLAN LU SH 2.1 FLOOR PLAN - WEST SH 2.2 FLOOR PLAN - EAST W > SH 3.1 CEILING PLAN - WEST " SH 3.2 CEILING PLAN - EAST W SH 4.1 INTERIOR ELEVATION J SH 4.2 INTERIOR ELEVATION .1 SH 5.0 DOOR SCHEDULE \\\ > U 4‹ OFFICE PRODUCTS (1) NORTHWEST N CO SITE PLAN (1) PROJECT INFORMATION RECEI 1U\_ 12VED MS NOT TO SCALE OFFICE TI FOR CACHE VALLEY ELECTRIC OWNER: cm/ VINE CREEK PROPERTIES, LLC . Iii n - 12550 SW 68TH AVE. TIGARD, OR 97223 > iii Li] LU CHARLES MINICH,MINICH, DIVISION MANAGER / PHONE: 503-431-6600 , FAX: 503-624-1436 r_ ,,, • CNI 1 CHARLES.MINICH©CVE.COM Ce fm _ L_ _ I _ _ _ __,_ _ _ _ _ _._ ___ _ _ _ _ - - GONZAGA BUSINESS PARK BUILDING A 0 Ce 1 I - LOTTAX NUMBER 800 1..L.1 M... Z 0 .L. .— 0 RI 0 DISTRICT CITY OF TIGARD —I M WI 1 1 , 1 I : CO —I = 1 i BUILDING AREAS , _ 0 0 > = 1 GROSS RENTABLE 11,641 SF 0 ACCESSORY USE -1,805 SF r= I:e c15 CI NET OCCUPIED AREA 9,836 SF TENANT OCCUPANT LOAD g ci gicr 0 9836 / 100SF PER OCC =99 OCC MAX gii- _ BUILDING IS FULLY SPRINKLED K . - - - i - - - - _ - , - GENERAL CONTRACTOR: ,-- L.— --±1 DURUS CONSTRUCTION 0 CHRIS BAILEY Z 503-320-5633 cm .1-- _1 ------, I I DESIGNER: = Ca BRIAN HAMILTON UJ 1 1 , 971-235-1198 (...) • LEL i I CITY OF TIGARD i— U_. 1 , , REVIEWED FOR CODE COMPLIAN61 LU 0 1 1 1 Approved: i 1 UJ cj ce - - - -, - - - . - - - ---- - _ _ _ Permit til I---61 GLA) .P-0 IC-to -.‘:14-cloP--9-:kilUz Address: i so si...> Os•,--- ei-dt- , (I) CD Ci ir:ce Suite#: ' ' 7[rz.iE t , By: Akiriariel Dates LU b 0 _ > ILI p El , BUILDING PLAN OFFICE COPY 0 0 >- Nur NOT TO SCALE LU _1 —I LU = C..) 0 DATE: 06/28/16 UPDATE: _ SHEET 1 . 0 PERMIT SET i Y LU W W J GENERAL NOTES HVAC NOTES Q 1. VERIFY ALL CONDITIONS ON SITE AS THEY t THE SYSTEM SHALL BE CAPABLE OF PROVIDING RELATE TO THESE DRAWINGS AND NOTIFY COMPLETE HEATING AND COOLONG TO MAINTAIN DESIGNER AND OWNER OF ANY DISCREPANCIES HUMAN COMFORT BETWEEN 50-90 DEGREES PRIOR TO PROCEEDING. FARENHEIT. 2. COMPLY WITH ALL CURRENT UNIFORM BUILDING CODES AND ALL OTHER APPLICABLE U CITY, COUNTY AND STATE CODES AND ORDINANCES. PLUMBING NOTES FIRE PROTECTION NOTES W LLI 1. PROVIDE ALL PIPING, FITTINGS, VALVES, BACK 1. PROVIDE ALL DESIGN, ENGINEERING,, A RI AL ENGINES MATERIALS W S FLOW PREVENTION DEVICES, PLUMBING FIXTURES AND LABOR FOR A COMPLETE AND OPERATIONAL FIRE C/) AND OTHER MISC. COMPONENTS FOR A COMPLETE PROTECTION SYSTEM IN COMPLIANCE WITH UBC CN SYSTEM. STANDARDS, AS APPLICABLE. LI ti 2. COMPLY WITH ALL PERTINENT REGULATIONS OF 2. ALL SPRINKLER COMPONENTS SHALL COMPLY WITH THE MOST CURRENT UNIFORM PLUMBING CODE, PERTINENT SECTIONS OF NFPA AND THE UBC. © ce w THE UNIFORM BUILDING CODE AND THE STATE OF 3. AT LOCATIONS WITH CEILING TILE, HEADS OF Z OREGON STRUCTURAL SPECIALTY CODE. SPRINKLERS SHALL BE LOCATED IN CENTER OF THE TILE, - ( ) N a0 3. ALL NEW PLUMBING FIXTURES SHALL COMPLY UNLESS OTHERWISE APPROVED. m J W WITH ADA REQUIREMENTS. 12 4. ALL PIPING PENETRATING RATED WALLS, FLOOR Z W = 0 AND CEILING ASSEMBLIES SHALL BE PROPERLY 75 p FIRE o � CAULKED AND SEALED. 5. ALL HOT AND COLD WATER PIPING SHALL BE H INSULATED. - - 0 U7 SI 111 w a ELECTRICAL NOTES Z 1. COMPLY WITH ALL PERTINENT REGULATIONS OF a r THE MOST CURRENT NATIONAL ELECTRICAL CODE, cc THE UNIFORM BUILDING CODE AND THE STATE OF O 0 OREGON STRUCTURAL SPECIALTY CODE. W U p 2. ALL NEW ELECTRICAL DEVICES SHALL COMPLY Z EE WITH ADA REQUIREMENTS. W U < 3. ALL CONDUIT PENETRATING RATED WALLS TO 0 w 0 BE PROPERLY SEALED. I- -J w a CL 11 w v U DATE: 06/28/16 UPDATE: - SHEET 1 . 1 PERMIT SET SHEET NOTES Ce 1. PREPARE EXISTING WALL FOR INSTALLATION OF I— NEW WALL. U LU 2. DEMOLISH EXISTING WALLS, DOORS, AND —1 ELECTRICAL. LU 3. REMOVE EXISTING EXIT SIGN AND KEEP FOR REUSE. 4. REMOVE EXISTING LIGHT FIXTURE AND KEEP FOR REUSE. >LI: 5. DEMOLISH GYP. BD. CEILING, LIGHTING, AND CONTROLS. I 6. REMOVE EXISTING DOOR. DOOR SWING TO BE kJ REVISED. Q 7. DEMOLISH WALLS, DOOR, AND WATER HEATER. U I I I I 0 - - - - - - - n n - - - _ - - - - - - - - - - - - - - - - - I II Otill :!,,.. _i � � -k.7.,,N � , � II O 11 I � � �}� . 1 @ II Il bz,# 1.114,E) E) I %, *A-04,**- . , ,, iri, LU is W ILLI — a - rte .. w.77 .- __ I C/] M = r I I I I Q N (TYP) 0C� ti 97.7, 0 0 C, rn I I I I Z Z a� (-) 0 • • !V 0 4)1M 0 0 � V � zw = 0 E) z � co o I I I I O 5 0 - _ - - - - - - - - - - - - - i!- - - - - - - - - E) O V' (NM 1 CD M J_ 1 CO I I I I 0 w 0 c.)E) � LU � I I I I U- 0 ❑ O a ' dw 2642 Z U R 0 *II , I I,,.L- Ganz I 1= II AAw J © w o II 0 (E) J J l 11 , .n,, i ' _-_IL +� LI -- — — — — I - - - - - - I —t - - - - - - - UJ V I I I I U DATE: 06/28/16 UPDATE: 0 FLOOR PLAN - DEMO _ _ _ SHEET 118" - 1' 0" — �••••••�• 2 . 0 0 8'-0 16'-0 24'-0 32'-0 PERMIT SET GENERAL NOTES SHEET NOTES a Ce A. SEE DOOR AND RELATE SCHEDULE ON SH 5.0. 1. ALIGN NEW WALL WITH EXISTING WALL. I-- C..) -•LI B. NEW WALLS TO BE 5/8" GYP. BD. ON 3 1/2" MTL. 2. ALIGN NEW WALL WITH EXISTING WINDOW LU STUDS @ 16" ON CENTER. USE R11 BATT MULLION. J INSULATION. W C. PROVIDE WALL BLOCKING TO SUPPORT ALL >11 WALL MOUNTED ITEMS. W J ti, W w z < J [ o . V / 15'-3 1/2" 10'-9 1/2" 11'- 1/2" I' 11'-9 1/2" 12'-8 112" M 0 a OFFICE 13'-6" Li OFFICE OFFICE OFFICE OFFICE 18'-11112" (L(.. rij (1,:, C� W a w 1 L AG7 SH 4.0 +.. .:, M ©• N Ce Nft- 101-6rr I I 0 LU Z OFFICE I) Z '-c Q I` ,Ark m I Z W OC / 14'-4" CD > z O SH4.0 Ct 00 ii= 70'-8 112" 9 -8- - - - - - - - ,- - - - - - - j - - - - - Ct 00 0 R1. I--- CD 11'-3" r OFFICE Z CI D ..10., C I— —I t SH 4.0 w CO UJ G U 00 o Imli) ,____ W do 181-11" z (-)13'-10 112" CD CI- ! _ OFFICE OFFICE OFFICE z Ce CeCe OFFICE (E)CONFERENCE U 4) © J ~ 0L W - - - - - - - - _ - - - _ ----r-- _ _ - _ C/ L U © J / 15'-3112" L 10'-9112" 4 11'- 1/2" 9'-1" 0 Q -I 3 LL W CD . CD I DATE: 06/28/16 UPDATE: - 0 FLOOR PLAN - NEW - WEST SHEET 118" = 1' 0" im um ■ ENE NE NE • • • • 2 , 1 0 8'-0' 16'-0' 24'-0" 32'-0" PERMIT SET GENERAL NOTES SHEET NOTES Ce A. SEE DOOR AND RELATE SCHEDULE ON SH 5.0. 1. ALIGN NEW WALL WITH EXISTING WALL. I- U B. NEW WALLS TO BE 5!8" GYP. BD. ON 3 1/2" MTL. 2. PROVIDE NEW WATER CLOSET, COLD WATER W STUDS © 16" ON CENTER. USE R11 BATT PIPING, AND SANITARY SEWER PIPING. - INSULATION. W 3. REWORK DOOR FRAME AND DOOR TO CORRECT C. PROVIDE WALL BLOCKING TO SUPPORT ALL DOOR SWING. >- LIJ WALL MOUNTED ITEMS. J J ti, W I U I U M latj • @IT\ • (E)OFFICE ¢-, I (E)OFFICE 4 - - - / „,L • ..... . J r il i_-_-,:i,„ , ',,, __ _) r W LL! Iw- 1• 8' 2.2 I ` f-, = ci N - \ 0 ADA CLEARANCE - ce N- Ali (E)OFFICE 0. NW Z CSC _ �., o 13'-1" 05' -- -' Z f;i9j o co z w = o E- ._ 1 1-- - - - - 3 8 28'-3" - - - - - - - - 402 f f T.) ENLARGED FLOOR PLAN - TOILET ROOM C] z ti F— I I 1 1 �r1 = lrOrr = = t II • • SH 4,1 MI � • • � 0 4'-0N 8'-0' 12'-0' 16'-ON C..9 I � M (E)OFFICE Q J_ . I-' 5 CD ca w w U- 0 w,` E OFFICE w taxa: 0 ii (E) FFICE (E)OFFICE (E)OFFICE (E)CFFICE (E)OFFICE ..-- S Z F.7_ r-g-, J 1 IU' ____,/ D. Ed - - - T - - - - - - -t-- - - - - - - - C 0o J Q I I J I-•1- w C ) Q U DATE: 06/28/16 UPDATE: - * FLOORPLAN . NEWEAST SHEET 118" = 1' 0" ■ NNE 2 .2 0 8'-0' 161-0' 24'-0' 321-0N f PERMIT SET GENERAL NOTES SHEET NOTES W A. PATCH CEILING GRID AND TILE WHERE GYP. BD. 1. NEW T-BAR CEILING TO MATCH EXISTING. 1— SOFFITS SOFFITS WERE REMOVED. (4) 2. RELOCATE EXISTING FIXTURE TO NEW LOCATION LU B. ALL LIGHTING FIXTURES ARE EXISTING TO BE INDICATED. J REUSED. REFER TO DEMO PLAN. LU 3. NEW LOCAL CONTROLS FOR LIGHTING. 4. TIE INTO EXISTING ROOM CONTROLS. LLJ J LEGEND til LU w (E) 2X4 LIGHT FIXTURE TO REMAIN z1 z (R) LIGHT FIXTURE TO BE RELOCATED 1 I I I- 2 ppiP EMERGENCY LIGHT FIXTURE MTh EXIT SIGN Q(TYP) 1 . (E) (E) EIMI !!Inall , R OFFICE ) OFFICE OFFICE OFFICE OFFICE 0 (E) `...-----".. 1E (=E) '' '.--- 429' Ein 1 111M ------‘1 EMI17- . I ill „ 0 0 0 0 LU 1-- Q(TYP) R 1 r ) 0 Ce ti Ce,�1"E1 -; 1E) p Ce (E) OFFICE / 0 (`-) i Z J N LU . IE) ' 1 (E) CC] J CD7 Z O (E) -, ,E; OctZ L.J� o Uc (E) 0 3 0 I (E) (-) (E) ' (E) 1-=) (E) (E) . (E) (E) (E) (E) \\of...F.1z_ Z (E) C] Q (E) (E) f-,.- J (E) E) (/) w m \ 0 0 -1 ,E, (E) 16 1 LL ..=. 1(R) I, . 1 ®(TYP) wce (::) � E) _) I Z O 0 1 U m- tg. — OW OFFICE OFFICE OFFICE z Cly OFFICE F, (E)CONFERENCE ' U 5.2 J I- Q. W - - - - - _ �- - - - - - - � - - - - 0 w Z J J J w CSI LU z C.) C.) 1 DATE: 06/28116 UPDATE: -- REFLECTED CEILING PLAN - NEW - WEST Ili SHEET 118" = 1' 0" m imumm 3 . 1 0 8 -0 16 -0 24 -0 32 -0 PERMIT SET GENERAL NOTES SHEET NOTES V Ce A. PATCH CEILING GRID AND TILE WHERE GYP. BD. t RELOCATE EXISTING FIXTURE TO NEW LOCATION i— SOFFITS WERE REMOVED. INDICATED. U W B. ALL LIGHTING FIXTURES ARE EXISTING TO BE J REUSED. REFER TO DEMO PLAN. W 11- LEGEND 4411j LEGEND W 2X4 LIGHT FIXTURE TO REMAIN (E) U w zI Q _ (R) LIGHT FIXTURE TO BE RELOCATED H • 1 2 EMERGENCY LIGHT FIXTURE I - - - - - - - - - L - - - - - - - - L*4ll EXIT SIGN • _'1 F (E)OFFICE (E)OFFICE I • -ti } w ,, w w I- (F) (E) (E) ;'E;) - (E) I I (., = i r C CO V lE) I -- i (E) > Ce I I(F) (E) (F', 1'j (E)OFFICE 0 w a� (E) (E) (R)I I (E) Z LU O J RI co I Ca J = Ce (F) (E) I 0 > _ (F) (E) (E) - - - - - I - - - - - - - - - (F3 - - - 1- co (E) (E) ,F- (L g 0 .4. 0 (E) (E) EM M f- d(TYP) E) (E) (E) (E) (E) (E) ( L; (E1 (E) :E (E) (E) I Fi (E)OFFICE Z (E) `,L; (E) (E) f I CI (E) I. - (E) (E) `1 (E) I m I F < LLI (�) (E). (E) ,. W U (E) (E) i i:i I 1 L.L (E) (,,7-_ (F) I O ; . w Ce (E)OFFICE Z Q 'O I C...) CT (E)OFFICE (E)OFFICE (E)OFFICE (E)OFFICE (E)OFFICE Z EE Q (E) , (F) ( U 0 0 >- J J < ' I w > 0 W Z U • U I DATE: 06/28116 UPDATE: - 0 REFLECTED CEILING PLAN - NEW - EAST SHEET 1!8" = VViim m • ■ M •• IIM • • • • 3.2 0 8'-0" 16'-0" 24'-0" 32'-0" PERMIT SET V W U LU J W O O O O ,,,, J Q W U a V CA) ELEVATION - NORTH > W W I— M CO co O O O O — DN D Z LLIo \ \ \ \ >- ---J Z W � J 0 > = O D o Q O D z ti 1 B ELEVATION - WEST 0 Z_ D -J CO Z W O � t Q o > o � EXISTING W C_) O J CJ D i i O W 1_ Q CD O Ce UO O w W Ill w Z Q 1111011M >.W = U Q CJ 0 ELEVATION - SOUTH DATE: 06/28/16 114" = 1' 0" NE imi ■ ■ • is UPDATE: - 0 4'-0" 8'-0" 12'-0" 16'-0" SHEET 4 . 0 PERMIT SET V I-- / 33'-6" / (, 4' J (TYP) 1 EXISTING LU `` ›— LU LU \ / (2)4' ROLLER TRACK DOORS. (1 ) STATIONARY AND (1) MOVABLE Q \ / i Q.0 w / \ / \ U OPEN TO /OOFFICE \ Q / I \ V A ELEVATION - NORTH / 21' / W 4' > W (TYP) W icril— cy, \ / z w z. >- Jzw \ / m JM W (2)4' ROLLER TRACK DOORS. / \ 0 > = 0 1 STATIONARY AND 1 MOVABLE � ( ) ( ) /0131\1TO\ I— C/) ce ro- / OFFICE \ u— > o Q / \ ! . O 0 Z ti R. B\ ELEVATION - WEST NE •• • ■ ■ ■ i O •• ■ ■ ■ ■ z 0 4'-0" 8'-0" 12'-0" 16'-0" J_ M m Z W O ` Er_ Q p: O > O W W U O J U_ 0 W � ce UQ O0 '-__.9 F—_ 2 W W w Z Q W _ U Q U DATE: 06/28/16 UPDATE: - SHEET 4 . 1 PERMIT SET V Ce U IW J W >- W J .J <,44..._ W Q U DOOR & RELITE SCHEDULE NO. SIZE TYPE FRAME GLASS NOTES WIDTH HEIGHT THICKNESS CORE MAT'L RATING MAT'L FINISH RATING WIDTH HEIGHT OA 3'-0" 8'-0" 1 3/4" SC WD NR MTL PTD NR — — (E)DOOR, RE-USED O 3'-0" 7'-0" 1 3/4" SC WD NR MTL PTD NR 2'-4" 5'-8" O PR 2'-6" 8'-0" 1 3/4" SC WD NR MTL PTD NR (E)DOOR, RE-USED O PR 2'-3" 7'-0" 1 3/4" SC WD NR MTL PTD NR — — EO 3'-0" 8'-0" 1/4" GL MTL PTD NR 3'-0" 1'-8" SOLID GLASS DOOR WITH TRANSOM FO 3'-0" 8'-0" 1 3/4" SC WD NR MTL PTD NR 1'-6" 5'-0" (E)DOOR W O 3'-0" 8'-0" 1 3/4" SC WD NR MTL PTD NR 1'-0" 8'-0" (E)DOORLLI W O 3'-0" 8'-0" 1 3/4" SC WD NR MTL PTD NR 3'-0" 8'-0" (E)DOOR;(N)RELITE = CD 3'-0" 8'-0" 1 3/4" SC WD NR MTL PTD NR 3'-0" 8'-0" (E)DOOR,(N)(2)GLASS RELITES \ co• 0 3'-0" 8'-0" 1/4" GL MTL PTD NR VERIFY 8'-0" SOLID GLASS DOOR W/(3)RELITES \ / > C) N KO 3'-0" 8'-0" 1 3/4" SC WD NR MTL PTD NR 2'-4" 6'-8" C) 0 LO 3'-0" 7'-0" 1 3/4" Sc WD NR MTL PTD NR — — FLUSH WOOD POCKET DOOR Z W ZO U >' —1 Z W m W CD > = O TYPE ® TYPE 0 TYPE 0 TYPE 0° TYPE © M Ec_ c.--75 ic-2 0 < g Ffa = o p Z ti H 0 Z p / m W W U J LL LL D a 0 o TYPE ® TYPE 0 TYPE 0 TYPE 0 TYPE Q TYPE 0 TYPE 0 W V O = U Ci U E Q U O W E_ O W O >- J J W _ U Q U DATE: 06/28/16 UPDATE: - SHEET 5 . 0 PERMIT SET