Loading...
Plans M EC2018 - 00200 w ¢ ao z. z o• aL.Lu Ww o '''i 'i ry.. AFF. ABOVE FINISHED FLOOR 60 co z00 W e. ..J .c, Z ,,,I-6 w- O Iv BF.C. BELOW FINISHED CEILING 3a �' o z Len'u_ � • caw o 0- 0 C7 MD: `2 2 18 BOD BOTTOM OF DUCT 16- 02 W 32 X ? T'° C� ' CD CEILING DIFFUSER - t-BAR La.(7) • �� 0 BUIL• T T i� CD-1 CEILING DIFFUSER - SURFACE MOUNT �,n W " oQ = z �rJl� w a 4,w C sJ CEG CEILING EXHAUST GRILLE - T-BAR 00(50 v_, zo 2 CEG-1 CEILING EXHAUST GRILLE - SURFACE MOUNT 1 �2 o5 o • ( J tom (- 3co�`g`5 °- � 2< V a / CRG CEILING RETURN GRILLE - T-BAR =F.-E., j o CRCs-1 CEILING RETURN GRILLE - SURFACE MOUNT w-ocx o ~ w�owo azo ►� CTG CEILING TRANSFER GRILLE - T-BAR N�itS-L1 NAz ¢s (fir �N CAP ,m,r� z ZU • REMOVE CTG-1 CEILING TRANSFER GRILLE - SURFACE MOUNT zxomz 3 D. 1" SD 1" SD 1" SD I" SD -1" SD 3� F �u- mz \ ____- - r,__=150 150 -: 150_:_ 130 - --__130_,_,_— ,11 X D 3 g W? W M Z } E/A E HAUST AIR r ID ' - r-- -- -. ( - ESD EXPOSED SPIRAL DIFFUSER 0 a F R dap ix FSG FLOOR SUPPLY GRILLE LIJ • muumuu: -J [ io�§ o �=fnF', i�ilia6el .l•�]J■II��ii-. li..ur ■■:: • FRG FLOOR RETURN GRILLE H I■■■■■ ■■riles - - ■■■!.. Y - - -MiCz■I�i - 8110 \, p RETURN Q --1 rr�; �. u t�` i \ R/A RETURN AIR Q it , i • . -6-3-' - N 1, ©,,, . , • S/A SUPPLY AIR 1 ©, ! I 11 O _ _, I 10".0 �,\ iNimmE ■■■■■.__ eji.__ _-- ■ r■■ ■■■■■ r__- Alm ■■■ ■ III • SD SLOT DIFFUSER - t-BAR 43 ■■■■■_ . ■■... • • ,r..: ■■■■■11111111111111111M ■■■.. -_ ��! SD-1 SLOT DIFFUSER - SURFACE MOUNT Cl) as ea 15f 145 DB 1 ,� i �i LLI Ti • _I= l 1 it ��__ --- I _ F ii_ -- __ t_ 8V 18/12 DB SWE SIDE WALL EXHAUST I- - up _ . 6-10 -- 7 - Q --1--- _ _ __ r...- ->q SWR SIDE WALL RETURN O 4.5 KW m■■x1111 - , SWS SIDE WALL SUPPLY 0 �MId 1'�` 1-21111 -I ■■■u■ mla� 8° ■ ■■ cu II V V b- 1 :' Illiilli 'l V 1 Na80 _ SWT SIDE WALL TRANSFER GRILLE O 7 •4sII 1 TJS THROUGH JOIST SPACEL. �� 120 60 120 ya 7/15 DB .111x,, 1 —' : 1 � , ���`�� �' h�� I. iiiii11 _- : iie. '"�+` ,_�_� __ ___, I O`� j TOP TOP OF DUCT W 112 8 D•c .4 I •-.-12 12 DB 1 �� ' �� ®®® VENTm VTR THROUGH ROOF _ _ 60 - , X,' 1 Vii, -= ■■■■■ a ■■■ SUPPLY DUCT/DIFFUSER GRILLE .1- : 60 r ; ■■■■■ - - - - cCO } z TU 6 1• x;,1;X;> 1 lw' - � �• CD I I 121 RETURN DUCT/DIFFUSER GRILLE a 40/12. L_r 6 ■ EXHAUST DUCT/DIFFUSER GRILLE 1� ■ ®■■ ■■■■■ _ �o C I i�iii .. iiei= 120 ... ■ 1201 ® --; - - _.. i._..� -■■I■■■- ------■.Y■■■■■■■ ,. _---- l i Q . ■ II■■i®Q.-- ■■■■■■■■■■1. SIZE DIFFUSER 4 GRILLE CALL OUT 1 ®' ! �fi - ..rvvrVrr _ ti...._e 1. 111 CFM ® I '� rr, X aea�■_ ■sa�■ ____. I (CALL EQUIPMENT CALL OUT V' (\_'_:-_1' `erg nano\ L:: i:nN,'I4 ■■■ , p --i ==1 -' .� C d 11 ,' ® CONNECT TO EXISTING _ i - 60 •l �,II - I■■I■■■/1 - ■■■■■ ■■■■�i __.T SMOKE DETECTOR U 3 36 SL i 1 i _ - -� -] VAV 6-12 i 1 k 0 ! - m ®- SMOKE DAMPER O A - -�� : I 1 .---.f.':. 23/11 i�1F 23/13 SL® 1 - r- I- ii, jMD- MOTORIZED DAMPER = e_69 ii • �+ 80 CD "TO • O�l® II _ ,�� ! 200W .- I* - 5/DO L�' it BDD f- BAROMETRIC BACKDRAFT DAMPER �j O '215 "... 44714 == - \= 1( VAV 6-13 !..__. ■■,■■■'_ O�� i�a•: 6�I I -' W ' I z - --- 'I 1 ►i�■�i!�ia;s ■■..®aI .�■I_■■ �m KW NYE C1 Q EXISTING TO REMAIN .-1 i.II I'x. ': lug I I '! RELOCATE IC �i 1-64 co 1 X REMOVE I I - O-260 // r--- -— f; ! O 10" CIf 1 iI nu " 1r�!. _t _= 1 120 ',1 ' 24 1-2 DB I; 01 Z w - ilii�11�11/ i NO NEW O a0 Z N ■■i.■w■ I _ 8� 0 Z W e►® m ■■■■■ ■■■■■ ■■■w► ' !' ® FIRE DAMPER - FD _ _, >, � o � ■■I■■■ ' ■■■■■ �Ilu��y■ Fig. it ---- 1 1 i ■1■■ ■■■■■- ----• ■m _ i ; .. : I :� I _ 1, X` Q 1 �' DAMPER - FSD IL-- �■■�s �� FIRE SMOKE •am.1■I■ ;: ���1a.1, Q :.�------ �I I ® a 1;40F� �1 �-1 ■■■■s ■■■al.,a II I O w• i1?iiii� •���. •" N 1 VOLUME CONTROL DAMPER - VD _ v),� !- . _ 81215 CD® _ I - I� O TEMPERATURE SENSOR ^ A :ant In uu 111 II Ulmunuulm ,nnn muullmuuumuulu _ -11 11111 ■■■■■ ■■■■■ 11 u BROA ' J ■i 11■■■ ■■■■■ ■ ■■■EMMEN 1 !' OT THERMOSTAT O 1- L-1501 N Imo I �a� ®` I j 8� _n _ �F - �' _ hlmmlrmlmr,,,mrrrlrrmr111111111111�,,,Imrr,rm,r„r„11,U„ I II II 11111111111 1m1 III,I:lui' 111 I IITR!1111111, �` ' ty .� ' —_- -- PS PENDANT THERMOSTAT tJ m. ;T -? - ----1------,--4--. - - I jI I �' 0 Fal ' ... - I I ... ® — _ - �P PRESSURE SENSOR O r a�-i - I 1 , H HUMIDISTAT tii _I ' a`Qi - 6 O i� I z; a5: c"a; :-' �' a ' O �I. F+i _ •: �� rl■■■■ ■■n■■ - :1.._..I �_� I. 1 I ■I■■■■ ■■■■■ 80 /1 �� ■1.■■m_ __ ■■■�■ �... ...__ _ . _ _. CO CARBON MONOXIDE SENSOR - 100 i 404 ♦ �' .■■■■ Ill r-- _ -40.1.1 .:\,-0 t._-- •■®■■ -_,r CARBON DIOXIDE SENSOR Q /1 I 12 8 .L r� II c.) o P136-2®6- 9 • i---ITH . ,(�.r 5-G� GAS PIPING N 8s 3m KW r _= �w �h►� // ss. 8� Il1 ii l A DUCT WITH LINER ® rro —TimLi .:: I I SUITE 1 I !_ 1 �1 a, O -- --- 4�'--alr rJ II J'a�o - I_ ��■■i "um 8 ' ■r■■■ 1, '! II • -• _I i DUCT WItH LINER ®► r i —1 �_ I Inn --+ _ � 18 15 DB - ICO • �7 ; - ® NEM= 111 rCI t, I _pj NEW LINE tYPE tYPICAL iiii l _A. L_� 1 I w.�■■■ 1 . , - s ] I� r:, ®� EXISTING LINE tYPE - tYPICAL �® co 100 m i — • 16/12 DB �■■■■ v. p> I'. f1!.l- " ,n x r -..a� ! I ■■.o e, _ 25/15 DB n 10, 10 Dg ■■�>a •p v+ III ■O c I N ISI ' •B ®illi -- = 1PA= - - - - DEMO LINE TYPE - TYPICAL PI _ ��,____ . 10 - 8 - pyo r 22 2 DB . 80 p ! O d- __. _._. _- ; 1 , A `�',l1,"`- RETURN AIR BALANCE TAG N 0. 12 12 D: 12 12-D$ MEMO ■ 8b ' 1 � r w I U • •: _ - .. _ = MIME ■8=■° fIO SUPPLY AIR BALANCE TAG el ( EXHAUST AIR BALANCE TAG = �I \_._ / T- -, =- -._._.( A ).________.1 ,_ • _ 1 ;i____ .1 _ - - T-, L_LJ CD KF 'i I/% OUTSIDE AIR BALANCE TAG I- p /� // • M2OO SCALE: NONE 0,. cv o z �� ♦ �. =vb..ra.lr��l .,n. a..>.�.,sa rme eao_>,r...et.a W z O 0_ -ctCITY OF TIGARD , o o Lu s ri )FA I IAL SIXT 1 1 O O F 1 AN = I IVAO .� REVIEWED FOR CODE COMPLIANCE JOB START DATE: NM2mSCALE: 1/8" = 1'-0" ��l Approved. j 3/1 c/2 f 118 / Itt \os 41«Ik ♦ OTC: J DESIGNED BAfa 0 H m O1 Permit#: r R- 0 oa-0 — QJOB SET UP BY: cJ Address: i ooan S w (-s rep.by r5 J. DAVENPORT g Suite#: .6.0.Q............ . 1 1 g • � By: Date: ,�.� �.- 1 SHT. NO. csi M 20 � a FILE: 118094M200.DWG - M200 I EDIT: 3/23/2018 12:21 PM BY DRAFTER3 I PLOT: 3/23/2018 12:24 PM BY JAMES DAVENPORT • ,. ` ` '``' ' w �ri=,, SHEETS IN SET 1 OF 1 -a OFFICE COPY