Loading...
Plans (65) MEC2O17 - 00677 6,.. c4\ u General Notes BUILDING LOCATION HEAJEIVED SW 72ND AVENUE SEP 0 6 2017 ,,,,,, 49D CITY OF TIGARD1 1/1•. L.—L. .�`. BUILDING DIVL. A ), 111-1,7,1 O D W 11 u �J r 10 (ID 12 1:1[ i 11111111111tRP' ) 4;j ' T O \r‘icrier-4101, -.- -,-II I 200 ••/ r..�7.114% T- - I j- _ �0 4007 250 x 250 8 8 I _ ` Y �� o4-41r , , ui wu I _ L 250 250 " 0 " �L 10"4 2500 0RTU-4 L - :O �, "luuuuuuuu.I— j 111 ,,, " .•4 > r..::.:.:.:.:vr..:r..:.:.......:r..:.:..:.:...........:.:...Ij �� NM ul rail III • i i i • gl ,`' 12" 1'2x4 Ce 13 0�� II I rIiJ ] 250 L=CTIhN P V TO 0RTU-3 e ui •14"m .:.:...:..:.:..:.:.:..:..:.:.i...........�:_ • x411) NOT TO SCALE I .... 14" • < - 20x20 8 (1 r- 404 RA GRILLE 225 \L 14"0 'T' 8 • 8 150 - 200 h' 12"D ; ''_ 17- 41I 14.D • 0 Z 12 " % I �� ] —i> 1250 " - ' 14"0 0 .1 ' 8 '-•- Z < RTU-3 y... .:.:.::::-s .v:w,A,.._-_ RTU-4 I ( 10 � �1 �f 8 ''300 '�la i� 3/4'�(N)GAS '• 14"0 mk ! 225 rsilml 16"0 - 12.0 0 CL iI 3 ."o(N)GAS Q 16"0 - .. :: 8 � 200 Ili 16"0 _o i _ I -_ P T 2x4 ;; 8 • i _I> 1 10"0 250 - i Fr8" 1 ______I12"0 _ • •. • I 1 • X ,- CO I I' 1 8 200 11 1"0(E)G v 225 V 10" " a Q 20"0 i CIL 8 ` 8 12"0 16"D 150 1 ® 150 $ , 8" • r 12x4 D • Ein � -0 2x ,' `fix I 200 • u • 1 . 8 • - a _ -QT RTU-1 225 - 4 QEF-3 x :4' ZEF-2 Q' 1 6RTU-2 �� EF 14"0 EF-2 0 f �� '4' H 8"0 VENT OUT RF • X vv..:.:..:¢w-.:.:.:w.v:¢.:y� 12"0 16"O —._' 8CITY OF TIGARD 2III 200 ,2x4 J REVIEWED FOR CODE COMPLIASSCE —� 250 20"0 .11 LA lir tr:ved: [ 1�jbio w 14"O lL110"� [ ] GL c ��`�s \ 2 s s / X -x : , , H ,I , , „ ,„ Permit#: 2C17-e6 b 77 11 16"� 266 �'/ + 10"0Address: 72� O(7 /M RTU-2 ��, RTU-1 s 1 Suite#: �'# 10 200 �� = o- 24x24 $ .° Date: ril ,4, 16"0LIU •I 7 RA GRILLE I - Y: 4 _S '&3 C7 1`0 8 mak3�4 0(N)GAS c 3/4 O(N)GAS 150 11111. -. 34"c(VENT"OUT"ROOF IIIIIIIIIIIIIIIIIIIIIIIIInI171I1I1I11111t unut uninnuui .,..,! .' THE ACTIVATION OFA DUCT 11 EF-1 SMOKE DETECTOR SHALL x— — EQUIPMENT SCHEDULE ACTIVATE A VlS16LE AND xKXxxx.q TAG # MFG. MODEL # TONNAGE CFM AFUE SEER/EER GAS BTU WEIGHT VOLTAGE MCA FUSE AUDIBLESUPERVtSORY RTU- 1 CARRIER 48TCD08A2A6 7.5—TON 3000 80% 11 120,000 835 LBS. 460/3PH. 20 25 SIGNAL ATACONSTANTLY RTU-2 CARRIER 48KCD05A2A6 4—TON 1600 80% 14 60,000 580 LBS. 460/3PH. 12 15 ATTENDED LOCATION OMSC \No. Revision/Issue Date./ RTU-3 CARRIER 48KCD04A2A6 3—TON 1200 80% 14 60,000 500 LBS. 460/3PH. 11 15 a1"D(E)GAS RTU-4 CARRIER 48VL300403 2.5—TON 1000 80% 14 , 40,000 336 LBS. 208/1 PH. 15.2 20 Firm Name and Address 0UH-1 EF- 1 PANASONIC VF05- 11VKS1 80 --- --- --- ---- 120 -- 15 EF-2 PANASONIC VFO5- 1 1VKS1 110 --- --- --- ---- 120 -- 15 OFFICE COPY EF-3 PANASONIC VF05- 1 1 VKS 1 110 --- --- --- ---- 120 -- 15 e ce ' UH 1 UH-1 MODINE PD- 100 --- 80% --- 100,000 100 LBS. 120 -- 20 -� 17—TON 380,000 -t� -0 NOTES: HVAC INC. RTU- 1 TO HAVE ECONOMIZER AND SMOKE DUCT DETECTOR S hs " " " 3/40(N)GAS -3/40(N)GAS a RTU-2, 3 & 4 TO HAVE OUTSIDE AIR HOODS Q,"D(E)GAS ALL ROOFTOP UNITS TO HAVE FACTORY SEISMIC HOLD DOWNS ALL UNITS OUTSIDE AIR TO BE SET TO MEET OMSC VENTALATION TABLES Project Name and Address ALL GAS EQUIPMENT TO HAVE GAS REGULATORS MILLENNIUM THERMOSTATS FOR RTU'S TO BE HONEYWELL VISIONPRO PROGRAMMABLE 7204 SW DURHAM RD. nTHERMOSTATS FOR EXHAUST FANS TO BE LINE VOLTAGE 9172 RD, OR O Li u u u ROOFTOP EXHAUST FAN FOR RESTROOMS IS EXISTING 24 EXISTING GAS METER IS 2LB. SERVICE i HVAC PLAN Z� M-1 SCALE 1/8" = 1'-0" Project Sheet MILLENIUM Date / 9/4/2017 Scale 1 /8"= 1 '0"