Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (13)
BU P2016 - 00343 _ ...___ . ________ _.___ ._ _. . NEx-FoRE • 1 Drawings for: RESPONSIBILITY SCHEDULE • T. TENANT STORE #8753 NOTE:THE GENERAL CONTRACTOR SHALL VERIFY ALL ITEMS ON THIS SCHEDULE GC= GENERAL CONTRACTOR LENSCRAFTEIZS FOR ACCURACY PRIOR TO BEGINNING CONSTRUCTION.ANY DISCREPANCIES cit cy �y LL= LANDLORD Washington� 1 y�� Square SHALL BE REPORTED TO LUXOTTICA PROJECT MANAGER IMMEDIATELY. �Q* 4..' * .4) 6,,,� MW= MILLWORKER 93UU S VV VY CISrIi n�ton Square Rd. % * ,, 4-''' �- N/A= NOT APPLICABLE DIVISION 01000 - GENERAL SUPL RD.. MIL EX'G RELO REMARKS Tigard OR 97223 BUILDING PERMIT T GC GC SHALL AMEND/PICK UP PERMIT &'u PAY ADD'TL FLLS;FEES BILLABLE TO NEXTORE AT NET COST;VIA CHANGE ORDER#1 PROFESSIONAL CLEAN-UP, FINAL CLEANING GC GC (2)CLEANINGS REQUIRED-(1)PRIOR TO PUNCH &(1)AT TURNOVER _ _ A Subsidiary f t I�1 LuxotticaGroup DEMOLITION GC GC FIELD VERIFY EXISTING CONDITIONS ANDSEE PLANS FOR SCOPE Construction for TEMPORARY FACILITIES/UTILITIES GC GC GC IF REQUIRED --� f� OTHER PERMITS, FEES,INSURANCE GC GC INCLUDING ALL LOCAL PEST CONTROL REQUIREMENTS,PERMITS,VERIFY REQUIREMENTS 4000 Luxottica Place Mason, Ohio 45040 RECEIVED TEMPORARY BARRICADES(W/LUX BRAND SPECIFIC LOGO) GC GC COORDINATE WITH LANDLORD.LOGO SUPPLIED BY TENANT,INSTALLED BY GC TRASH REMOVAL AND DUMPSTERS GC GC VERIFY TOWN AND LANDLORD REQUIREMENTS.GC.TO REMOVE/DISPOSE OF ALL BOXES/CRATES/TRASH OF TENANT SUPPLIED AND INSTALLED ITEMS,INCL DISPLAY FIXTURES&HARDWARE.DAILY CLEAN REQUIRED. DEC 12 2016 CUTTING AND PATCHING GC GC GC - • RELOCATION OF EXISTING MACY'S FIXTURES LL LL GC TO VERIFY UPON ARRIVAL ON JOB SITE THAT THE SITE HAS BEEN CLEARED OF ALL MAC'Y FIXTURES IN ORDER TO PERMORM AREA I CITY OF TIGARI _ CONSTRUCTION.NOTIFY NEXTORE PROJECT MANAGER OF ANY QUESTIONABLE ITEMS EXISTING. BUILDING DIVISION ASSET PROTECTION COORDINATION __ GC IF OVERNIGHTS REQUIRED,GC SHALL PAY AP VENDOR&COORDINATE OVERNIGHT POWER W OPS MANAGER. C3 V V INSURANCE GC GC TO ADD MACYS AS AN ADDITIONALLY INSURED PARTY ON CERTIFICATE OF LIABILITY INSURANCE. CERTIFICATES NEED TO BE SENT d- TO THE NEXTORE PROJECT MANAGER,NEXTORE PROJECT MANAGER TO FORWARD TO THE MACY'S PROJECT MANAGER. • O -- 9300SWre • i r u DIVISION 03000 - CONCRETE gm, RCV MSTL EX'G RELO REMARKS a i on ii O CONCRETE SLAB(NEW OR PATCH FILL) GC GC GC • G.C.TO FIELD VERIFY EXIST.COND.TO DETERMINE EXTENTS OF SCOPE.GC TO REPORT TO PROJECT MANAGER. - I03 LE0 CUTTING O F EXISTING SLAB-TRENCHING OR CORE DRILLING _ _ GC GC GC COORD.W/LANDLORD&AFFECTED TENANTS.VERIFY W MACY'S OPERATIONS PRIOR TO ANY CORING OR TRENCHING. ::::›i T A oR 97223 SIDEWALK AT EXTERIOR DOOR GC GC GC GC TO PROVIDE ALL NECESSARY CONSTRUCTION&MATERIAL TO COMPLETE EXTERIOR SIDEWALK WHEN APPLICABLE. • O C DIVISION 04000- MASONRY soPL RCV. INSTL EX'G RELO REMARKS -- r X O NEW ENTRY OPENING GC GC GC GC TO PROVIDE ALL NECESSARY CONSTRUCTION&MATERIAL TO COMPLETE EXTERIOR ENTRY WAY WHEN APPLICABLE. U i < -J DIVISION 05000- MISC. METALS ,.SUPL PCV. MSTL Ex'G RELO REMARKS0 • BASE BUILDING STRUCTURAL STEEL • _ _ n STRUCTURAL STEEL AS REQUIRED FOR TENANT BUILD-OUT N/A U (......) METAL FABRICATIONS GC GC GC __.... ---._.. _ - U) EXPANSION JOINTS GC GC GC t J ,. -� OCL 2 LANDLORDS ADDRESS : 3 JOB SITE ADDRESS 4 MACY'S KEY PLAN 5 VICINITY PLAN i , DIVISION 06000 - WOOD & PLASTICS SUPL RCV RUSTL E%'G RELO REMARKS - ate-+ . BLOCKING(INCL.FOR FIXTURES,SHELVES,SIGNS GC GC GC FIRE RETARDENT WOOD AND OR METAL PER AUTHORITY JURISDICTION/LL -- -- - __ MACYS FIRST FLOOR PLAN O Z ROUGH CARPENTRY,FIRE RETARDANT LUMBER&PLYWD GC GC GC i LANDLORD MACY'S CORPORATE SERVICES NAME Washington Square i W FLOOR PROTECTION(IF REQUIRED) GC GC GC DURABLE PROTECTION REQUIRED.PROVIDE WALK-OFF MAT AT BOTH SIDE OF ENTRY POINT(S)OF CONSTRUCTION AREA LENSCRAFTERS 955 SQ.FT- Z �l o CONST.COORDINATOR DAVID BOESSENECKER STREET ADDRESS _9300 SW Washington Square Road tJl a FINISH CARPENTRY GC GC GC ' =a v� STREET ADDRESS 170 O'Farrell Street-10 North CITY,STATE,ZIP -Tigard,OR 97223 QP �' .__._.L.t t _ T 1 t �a.., r O ti DIVISION 07000 - THERMAL&MOISTURE PROTECTION sum PLV. ,sTL E%G RELO REMARKS CITY,STATE,ZIP San Francisco,CA 94102 SPACE NUMBER A� J , I U co SEALANTS,INSULATION, FIRE CAULKING&BLOCKING GC GC GC SEE SPECIFICATIONS ` J �-'--`y� -r"-" � PHONE 415 515 0884 ."& :4 • .' J 1 d SPRAYED FIRE RESISTIVE MATERIALS GC GC GC IF REQUIRED BY LL e a )' , , THROUGH PENETRATIONS FIRE STOP SYSTEM GC GC GC EMAIL DAVID.BOESSENECKER@MACYS-COM �� i BATT INSULATION AND/OR SOUND ATTENUATION GC GC GC J L ' .1 a�\PA- � � ' WATERPROOF MEMBRANE GC GC GC EXTENT OF WATERPROOF MEMBRANE SHALL BE VERIFIED W LL BY THE GC �. CE) 2 LCM G001REV03 3 LCMG001 REV 0.0 Y (� woe 0 ,:"ti DIVISION 08000 DOORS&WINDOWS SUPL IRCV_ EASTL EX'G RELO REMARKS e EXIT TO 1 - ® ® f_. '••••••=P 1 h. a" , k x` I e EXTERIOR i _`' NEW DOORS, FRAMES, HARDWARE GC GC GC UNLESS NOTED OTHERWISE. (SEE DOOR SCHEDULE SHEET A101 i 0- ® p b\� " PANIC/SECURITY ALARM GC GC GC IF EGRESS DOOR REQUIRED E t '- '' I . 7JURISDICTION PROJECT El ii .MACYSSTOREINFO.INTERIOR DOOR LOCK CORES AND KEYS T GC GC LOCATION %'i ` qACCESS DOORS AND FRAMES GC GC GC ii d - y li �\�.\\,�,�,\\\.\��� �,k � ReVISlOr15' IMark Date B MILLWORK MIRRORS T GC GCIR ,: STORE CONTACTCITY Cristolbal Arana City of Tigard ) `^ n 12-2-16 STAFF STREET ADDRESS - 9300 SW Washington Square Rd- DEPARTMENT ;' 90 REVIEW SET v T _ BuildingInspections _ SVPL RCV INSTL Ex'G RELO REMARKS NORTH 9 q - FINISHES DIVISION 09000 S S NEW DEMISING PARTITIONS(STUDS&INSTALLATION} GC GC GC SEE PLANS FOR SCOPE OF WORK __________ 4.CITY,STATE,ZIP -Tigard,OR 97223 STREET -City Hall- 12125 SW Hall Blvd. �. 1 JO � NEW DEMISING PARTITIONS(GYPSUM WALLBOARD) GC GC GC SEE PLANS FOR SCOPE OF WORK. • _ _ 0- U_ • • . ) A DRYWALL CEILING,WALLS,ENCLOSURES&REQ'D FRAMING GC GC GC PER USG AESTHETIC ASSEMBLIES,ALL WALLS(INCLUDING EXISTING TO REMAIN),SHALL RECEIVE"LEVEL FINISH, &CE._ LEVEL 5" PHONE - (971)563-4557 CITY,STATE,ZIP -Tigard,OR 97223 l - : CI-) - - - - __.._.._ ... PROJECT ACOUSTICAL CEILING 2'x2'TILES&GRID GC GC GC `� # _ r.' - - EMAIL �ocxxx ( ) 18 2439IF PAINTING,FINISHING,VARNISH,SEALER,ETC. GC GC GCI __.._ .. _ -_._ _.._ _._. - _ PHONE o- LOCATION 503 7 FLOOR TRANSITIONS/VINYL TILE/VINYL WALL BASE GC GC GC VINYL BASE @ ROUND COLUMNS __. _-_.. -------..__ 4 LCM G001 REV 0.0 5 LCM G001 REV 0.0 CARPET TILE C 63 _ T GC GC GC MUST INSTALL FLOOR PER FLOORING MEG SPECS.REFER TO FINISH SCHEDULE SHEET A103. 6 LCM G001-REY0.0 7-LCM-G001-REV 0.0 CARPET(OTHER THAN C-63) GC GC GC GC MUST INSTALL FLOOR PER FLOORING MFG SPECS.REFER TO FINISH SCHEDULE SHEET A103. PORCELAIN FLOOR TILE T GC GC GC MUST INSTALL FLOOR PER FLOORING MIC SPECS. A GROUT AND THINSET FOR TILE&ACCESSORIES GC GC GC - TR 'CTION O" W LENSCRAFT __._ _-- pp .PT : THE PROJECT DIRECTORY q DRAINING INDEX FLOORING TRANSITION STRIPS GC GC GC ; -- ..__ ----._-__-._ Q CO D E IN FO RMATIO N DEPT N�CHANGE OF EGRESS OR 9 iQ WALLCOVERING WC105 T GC GC -----._ - - Oi..�_UP.AN�I Or THE @rCACYS STORE: - - L _ i WALLCOVERING WC106 GC_ GC GC - CONSTRUCTION TYPE: 1A 2.)ACTUAL WIDTH PROVIDED: N MANAGEMENT DRAWING TITLE REVISION# L PORCELAIN WALL TILE - T GC GC _ .. - - _..___ TIOEXIT#1 (1) 44' 10"OPENING = 538"CLEAR CONSTRUCTION CUSTOM WOOD MILLWORK WD201 T GC T - _ _ - EXISTING OCCUPANCY: M(MERCANTILE)[1383 SQ.FT.[ EXIT#2 (3)PR 3'-0"DOORS =204"CLEAR GC TO OBTAIN LENSCRAFTERS/MACYS CONSTRUCTION C REV0,0 3/4-X 3/4 WOOD TRIM -__ GC GC GC _ - EXIT#3 (2)PR 3'-0'DOORS -136`CLEAR NEXTORE , ___.--- -------.• - -. _... .._._. ..__ PROPOSED OCCUPANCY: M(MERCANTILE)/B(BUSINESS)[1383 SQ.FT./] EXIT#4 (2)PR 3'-0"DOORS = 136• CLEAR NEXTORE E ARCHITECTURAL 1 WOOD TRIM (OPEN DOOR SURROUND) GC GC GCCREAMERY BROOK 4000 LUXOTTICA PLACE ----- --� EXIT 5 R 3-0 DOORS =204 CLEAR # (3)PT 06026 MASON,OH 45040 WOOD BASEBOARD WB101&W8102 GC GC GC PAINTED P104 BUILDING: 2014 Oregon Structural Specialty Code(OSSO 5T 516393.2484 ,C _.. 7SHEETArchitect/ Engineer of Record 9 � 513 65 6000 G001 GENERAL INFORMATION/COVER CHAIR RAIL GC GC GC MECHANICAL: TOTAL EGRESS WIDTH PROVIDED: = 1_218'CLEAR -- -._--....... - �_-_-- 2014 Oregon Structural Specialty Code(OMSC) _ DIVISION 10000 - SPECIALTIES SUR RCV. INSTL WIG RELO REMARKS FIRE, 2014 Oregon Fire Code(OFC) 1015.NUMBER OF EXITS AND EXIT ACCESS DOORWAYS V100 MA L 1015.1.1 MINIMUM NUMBER OF EXITS: More than 1000 occupants/4 Exits required AD100 DEMOLITION PLANS - RETAIL WALL SIGNAGE T GC GC SEE FIXTURE,PLAN&ELEVATION SHEETS FOR MORE INFORMATION PLUMBING: 2014 Oregon Plumbing Specialty Code(OPSC) NEXTORE PROJECT MGR, NEXTORE PROJECT PLANNER -- - -- - - GRAPHIC HOLDER T GC GC SEE FIXTURE PLAN&ELEVATION SHEETS FOR MORE INFORMATION AD200 EXISTING ABOVE CEILING CONDITIONS C- ___ .__._...._.._..-._.._ -,_ ___. ___. ._....... ...-..._. ........ ....... ......._ ELECTRICAL 2014 Oregon Electrical Specialty Code(OESC) CONTACT: JASON STANELY CONTACT:RON WENDUS - __ GRAPHICST GC GC SEE FIXTURE PLAN&ELEVATION SHEETS FOR MORE INFORMATION TEL.: 513.765.3988 TEL.:516.387.3363 AD300 EXISTING ABOVE CEILING CONDITIONS - ACCESSIBILITY SIGNAGE T GC GC SEE FIXTURE PLAN&ELEVATION SHEETS FOR MORE INFORMATION ENERGY: 2014 Oregon Energy Efficiency Specialty Code(OEESP 2014 OREGON BUILDING CODE CHAPTER 29/TABLE 2902.1 EMAIL:STANLEY)@NEXTORERETAILCOM EMAIL:RWENDUS@NEXTORERETAIL,COM ,....... . C 0 R T L A N 0 _.. ._ _._._--_-_._. _. .. --____ -- .. . ......_____ _________.. -- P NT r81 A100 FIXTURE FLOOR PLAN. M O R G A N STORAGE AREA SHELVES&_SURFACE MTD.STANDARDSG _ __ GC C GC 3762 OCCU A S 1881 MALE FEMALE FIRE EXTINGUISHERS - GC GC GC SUGGESTED LOCATION ON PLAN-VERIFY LOCAL REQUIREMENTS ACCESSIBILITY CODE- 2009 ICC ANSI/117.1 A101 CONSTRUCTION FLOOR OFT�GA� D ARCHITECT GLAZING FILM-EXTERIOR GRAPHICS T T 'T MINIMUM PLUMBINGFIXTURES ---_ __ _ -__ ADDITIONAL CODES --- -- - --.- _ .__ YD FQR CODE COMP. • C TABLE 2902.1 MERCANTILE STORES A102 REFLECTED 7 1 1 N. FIELDER RD. DIVISION 12000- FURNISHINGS SUPT. KV WM EKG RECO REMARKS SPRINKLERED:YES NEPA 13 1�YCt11� ARLINGTON, TX 76012 1.}WATER CLOSETS NEXTORE STORE PLANNER PERMIT EXPEDITER A1o3 FINISH PLAN+�PF � - C1�C� � . • ��` PH: (817) 635-5696 MILLWORK(RETAIL) T GC T RECEIVED&OFFLOADED BY G.C./UNCRATED&INSTALLED BY TENANT.CONSULT NEXTORE PM FOR POSSIBLE INSTALLATION REQ- FIRE ALARM: YES NEPA 72 - - - -__ ___-__._._---.__ - __.__ __ REQUIRED:(MALE)1 PER 500 CONTACT:JILL ROEBEL Elder Jones Building Permit Service.Inc. - �T( � MILLWORK(O.D.) T GC T RECEIVED&OFFLOADED BY G-C°/UNCRATED&INSTALLED BY TENANT.CONSULT NEXTORE PM FOR POSSIBLE INSTALLATION REQ- FIRE EXTINGUISHERS:YE5 NEPA 10 TOTAL REQUIRED:(MALE) 4 FIXTURES 1120 E.80th Street,Suite 211 A200 INTERIOR ELEVATIONS r7� FAX: (817} 635-5699 OD EQUIPMENT- T T T GC TO COORDINATE T TEL.:513.765.3592 ry�y� :3-..- EXISTING PROVIDED ON 2ND FLOOR OF MACYS EMAIL:JROEBEL@NEXTORERETAIL.COM Bloomington, MN 55420 A201 IN ERIOR EL �AT QN r POS EQUIPMENT -- T GC T G.C.TO COORDINATE -- v ._.___ _.. EGRESS: OCCUPANT LOAD:TABLE 1004.1.2 ------- - - Contact:Tim Schenk ---_ � - ♦ • Seal LENS PROCESS EQUIPMENT T I T EXISTING MACY'S LOWER LEVEL FLOOR AREA OVERALL REQUIRED:(FEMALE)1 PER 500 Tel.952°345.6040 A300 SECTIONS IP OF AL ���1� - -- - - - ePt. 4 a _ _ . . - - -. ._ . . - -- email: -.-- - MERCHANDISE PROPS _ T GC GC RETAIL SALES AREAS 110493.9 S.F. /303683 46.17411 Date: Ijor 11 TOTAL REQUIRED:(MALE) 4 FIXTUREStims©elderjones.com =• EXISTING PROVIDED ON 2ND FLOOR OF MACYS A500 DETAILS FURNITURE(CHAIRS,BENCHES,TABLES, ETC) T GC GCEXISTING PROVIDED ON 2ND FLOOR OF MACYS • STAPLES PURCHASED ITEMS T GC GC - -..____..._ - ---- � ------ NONBUISSABLES AREAS 5694.1 S.F. / 100 00 = 19 H �ivl� DOCTOR'S CERTIFICATES/LICENSES T GC GCMEC A N ICA "A _ _ _ TOTAL LOAD 2.}LAVATORIES PROPERTY OWNER / REP. PROJECT COORDINATOR REQUIRED:(MALE)1 PER 750 _ t�? TOTAL AREA 122169.5 S.F.GROSS 3762 OCCUPANTSTCOMPANY:MACY'S INC. CADD TECH,INC. MPE100 OVERALL EXISTING FLOOR PLANS ,• DIVISION 15000 - MECHANICAL Suet PCV. INSTIL MG RELo REMARKS -_- -.--_ - LENS CRAFTERS PROJECT AREA EXISTING TAL REQUIRED: UIREPROVID.(MALE)ON 2ND FLOOR OF MACYS STREET:9300 SW WASHINGTON SQ.ROAD 225 OAKLAND ROAD - OFFICE ARLINGTON,TEXAS ACCESS PANELS - ---- GC GC GC COORDINATE WITH TRADES FOR SIZE AND LOCATION. - = REQUIRED:(FEMALE)1 PER 750 TIGARD,OR 97223 SOUTH WINDSOR CT,06074 H2D0' HVAC PLAN �F1' IJV' L.� 1 1� rrt,., ROOF WORK GC GC GC GC TO COORD.W/LANDLORD WHEN REQUIRED CONTACT:DAVID BOESSENECKER CONTACT:DON KAMM RETAIL SALES AREAS 602 S.F. /3020 HVAC DISTRIBUTION,DUCTWORK, DIFFUSERS GC GC GC TEL 415-515-0884 TEL 860-783-5670 EXT.101 PLUMBING • PLUMBING FIXTURES -- -__ .-_._._ T GC GC INCLUDING BUT NOT LIMITED TO SINKS, FAUCETS,DRAINS, ETC ------ - - -_� -- = FLOOR OFFMACYSS BUSINESS AREAS353 S F /100 4 TOTAL REQUIRED:(MALE) EXISTING PROVIDED ON 2ND FAX' FAX 860-783-5680 .- - FLOOR DRAINS/PIPING/SUPPORTS -- _ GC GC GC _ ° TOTAL AREA 955 S.F.GROSS 24 OCCUPANTS -_ _ EMAIL: EMAIL: A DAVID.BOESSENECKER©MACYS.COM P200 VENT PLANS AND DETAILS - .............. - ---- ---- .._. _-- Arehitect/Engineer Job No.: WATER AND SEWER CONNECTION GC GC GC • GC SEE PLUMBING DRAWINGS FOR SCOPE OF WORK SEE SHEET V100 FOR EGRESS LOCATIONS SPRINKLER SYSTEM MODIFICATIONS GC GC GC GC BY L.L.DESIGNATED CONTRACTOR AT G.C.EXPENSE.GCRESP.-FOR MODIFICATIONS, DRAWINGS,AND APPROVALS.-. ARCHITECT OF RECORD MEP ENGINEER OF RECORD ELECTRICAL SANITARY PUMP(ALL COMPONENT) GC GC GC GC SHALL PURCHASE PUMP FROM NEXTORE'S REQUIRED VENDOR.SEE PLUMBING SHEETS FOR CONTACT INFORMATION. EGRESS WIDTH PER OCCUPANT: CORTLAND MORGAN ARCHITECT NEXTORE SANITARY BOOSTER _ GC GC GC Nextore Store Deg Revision No.: 711 N, FIELDER RD Design INSTA HOT WATER HEATERS _ GC GC GC - - SECTION 1005.3.1(STAIRWAYS/SPRINKLERED)-0.2 INCHES PER PERSON ARLINGTON,TX,76012 E100 _-- PECIF ,SYMBOLS AND DEMOLITION ST S D MICHAEL ROMES S ICATION SYMBO - -.. _. ._..... _... .._ __..._ _ _ - --_-. .. ___...._.. .......... .. CONTACT:TRICIA RUSSELL 4000LUXOTTICAP CE REV 1.)EGRESS COMPONENTS SPRINKLERED) N MASON,OH 45040LA E200 LIGHTING,POWER AND LOW VOLTAGE PLAN - DIVISION 16000 - ELECTRICAL SVPL RCV i,sn ERG RECO REMARKS 0.20 INCHES PER OCCUPANT x 3762 OCCUPANTS= 752.4 INCHES(REQUIRED) , TEL.817.635.5696 TEL(920)445-5007 - 0,0 CONNECTION AND WIRING @ MILLWORK THROUGHOUT GC GC GC ALL MILLWORK LIGHTING IS PLUG&PLAYFAX 817 635 5699 _ EMAIL:TRIC @CMAIA NET MROMES@NEXTORERETAIL.COM E300 DETAIL&RISER ELECTRICAL SERVICE CONDUIT ONLY GC GC GC• _ ELECTRICAL PANELS/TRANSFORMERS GC GC GC GC TO REFER TO ELECTRICAL RISER DIAGRAM 10 LCM G001 REV N b 74095 8-LCM-G001-REV 0.3 9-LCM-G001-REV 0.0 00 extore project �9 - - - um er ELECTRICAL WIRING,CIRCUITING, RECEPTACLES,SWITCHES GC GC GC _ - RECEPTACLES IN MILLWORK T T T (WIRING AND FINAL CONNECTIONS BY GC) LensCrafters Design Type: EMERGENCY LIGHTING T GC GC -._ „, te� :f� ,$'' y � <;:���.. GLOBAL EXIT SIGNS T GC GC yj3 FIRE ALARM SYSTEM LL LL LL 1l COMIYIENTS 12 SCt?PE OF WORK NEW LIGHT FIXTURES-8,LAMPS T GC GC ....._._.. --_--_ PACE 1N AN oval ISSUED FOR: R• REPLACEMENT OR MATCHING EXISTING LIGHT FIXTURES&LAMPS GC GC GC I..) DEFERRED SUBMITTALS : SPRINKLER MODIFICATIONS, FIRE ALARM MODDIFICATIONS THIS PROJECT IS THE TENANT BUILDOUT OF AN EXISTING MERCANTILE S 0Client Review CZ LL Approval EXISTING INTERIOR CENTER AND INCLUDES INTERIOR CONSTRUC O . Ip DO Permit 0 Bid SOUND SYSTEM SPEAKERS • GC TO RELC3CATE WHEN APPLICABLE/MATCH EXIST.WIRE AND EXTEND TELEPHONE CONDUIT TO SPACE T T T ------------------------__._...._..............._...-..._.__� ---.................._.._ - ._..__..._..........._......__...__...._.._....._. m� Construction ' THE SCOPE OF THIS BUILDOUT WILL INCLUDE:(ONLY IN AREA DETAILED ON SHEET Permit-Re-Submit TELEPHONE WIRING TO SPACE T T T WIRING TO BE PLENUM RATED ______ rn _ -- - TENANT TELEPHONE EQUIPMENT T r T G.C.TO COORDINATE - - - P3 -T µ w - • CONSTRUCTION OF NEW NON LOAD BEARING WALLS Title TELEPHONE WIRING I T T WIRING TO BE PLENUM RATED _.._-...-- _-- .__---- • W FLOORING FINISHES GENERAL -_�._...._ • • ..................._._._.............---..- --.... • NEW CEILING CONDUITS-DATA,COMMUNICATION,ALARMS, PHONES GC GC GC TENANT'S LOW VOLTAGE VENDOR PERFORMS DATA TERMINATIONS • _ POS AND DATA WIRING _ _ - __ T T T GC SHALL PROVIDE ALTERNATE PRICE-SEE ELECTRICAL SHEETS.WIRING TO BE PLENUM RATED "•"`"""""'•".,.... ...•........................... a NEW FURNITURE AND FIXTURES ' WIRELESS EQUIPMENT T T. T.. • ...... • NEW OD OFFICE EQUIPMENT INFORMATION TERMINATION - ._......._......�_ _-_........._.... _....................__......._.. ..... . ,..__ •. NEW SIGNAGE AND GRAPHICS JACK 8,FACEPLATE-DATA _.___...._._.. T T T GC SHALL PROVIDE ALTERNATE PRICE SEE ELECTRICAL SHEETS. -- • __....._..._.-..._.._.............. . ..._.._._ _......_.....,:. ..m... m - -----_ • UTILITY WORK AS REQUIRED TO ACCOMMODATE PROJECT SCOPE --- ---- - _ _� .. -- Q COVER SHEET MACY'S BACKBOARD TERMINATION DATA T 7 T _-_ _-_..__ JACK TERMINATION&FACEPLATE-PHONE T T T GC SHALL PROVIDE ALTERNATE PRICE -SEE ELECTRICAL SHEETS. -. .. ._..-.. -..._._._.......... __ „ ...,,, .. 4 •� _ MACY'S BACKBOARD TERMINATION-PHONE T T T Date Sheet SECURITY-FACILITY(HARDWARE&WIRIN &G) GC GC GC COORDINATE W/ LL NEXTORE PM __ 12-2-16 1-LCM17-6001-REV00 11-LCM-G001-REV 0.0 12-LCM-G001-REV 0.0 Drawn By STAFF G001 Checked By CM A ,� G (2) PAIR 36" DOOR D E E.1 F G H J K L M N N.1 � � .^ `� 136 OF EGRESS EXIT #3 NEXFORE i o " - J I �_ I "1 J L . c a B t c 040 1 T - .-- - - 1-Ir Z="r l- 1 r , J -�i a000 Luxe Ica Place tila:on H aSm+.Q I _ lidiUP �, I •+1(51317b5-6000 I / -_- , y fi Creamery Brookba:Granby CT •=1(5361 3°3-2487 Vil-}UP ) \II i -1_I .\--TES STORE #8753 ,r�� �' -�`` ix Washington Square 1_, \ 9300 SW Washington Square Rd. ''11I Tigard, OR 97223 Elfi -] / , ,1 -7,11.2 a I Imo- ■ _ n . E,- il \ f 1 II I� Construction for: I >< >< 0 1-J ,--- 1 j1 / / Ll `=/' , j - PLYWOOD BACKBORAD O E . I I n ,,, el III 111111 la] cp g L4720 *CID ix k -1' ! H �i F 4NL21 R21 R1 - cLS ,,,_) >,... ! j WALL TURNS ) 1E_..-I. Q L I I_-I _-I- U L H _ Q Q1 POS { WALL TURNS +� PANEL i �1 j ❑ ❑ ® 56 x O IIII D IA1 ,, ...7 i ,-,, ,,,,, 0 ,... ,.. , . / I L--.- I -,--: I IKF J 5 0 1 1 o❑ I 1 �� I I I LDB 2 0 II-, e 11==i i I ❑� ,,. cius) O ci as I MEI I=I=I NOTE: 1.) PANEL R2 IDENTIFIED AS USABLE PANEL, BUT AS PER ENGINEER, ANY PANEL CAN BE USED D C) - 2.)ALL PANELS ARE ON CONTROLLED RELAYS AND CAN BE ADJUSTED TO 24 HOUR BREAKERS Z Ln X� � \ / \ / ILV�OCE&FTENE a Mai oEMVEa EEIL E EIEE IMIL, M� ..„0( QS dEr Z J o o 9.1 / /J 1 I I l„ Oi '; 1Q L•i•.i• L� En i L-1______________ l' EC QL[ g MOM 11.1.1 Q © ''� igRil mg ill i mi--.- - 1111 kS - �� ■ _ (9 _,,i2 * . IF Il 1 DOORPOCKET 0 I - 4!■ ■a HCl [ ft Al 1 • •........41 r IIJ - 1 ®I. •1/v i 1 i 0 • din G Ilkiki‘8.2 I C I I eQQOO p di III ' - ii� l - - / i I 1 o t 1 o I •1 in NOTE THIS DRAWING IS FOR GENERAL T # I I I �/ _ ��>7� -�� - ,+1. A\ DN . EXIT #"1 REFERENCE ONLY. TO SHOW WHERE THE Revisions: EXIT 2 �� ` Mark Date c By . ■- I a I I I I I o 44'-10" MALL ENTRANCE EXISTING MACYS ANDDWHERE THE THE A(3) PAIR 36" DOOR � i i I C../ _ 204" OF EGRESS TAFF -i / I I In n j^�_�� ► 538" OF EGRESS nn REVIEW SET �� rl NEAREST UTILITIES ARE LOCATED < LI -I - Q UP \ 1 A m s 0 - I �n I DOOR POCKET 1 II __'' Jr, - . - ,� L +�, �� „\ •c �i��i� ��� MACYS LOWER LEVEL EXIT SUMMARY Z _ a - - C - �''� " �� �/ =. 41, .� VI I EXIT #1 538" OF EGRESS WIDTH __\ - p `C1 - s� EXIT #2 204 OF EGRESS WIDTH /� ni I 71 _,____...___ _ ____... ..______ 7.1 I \1 I [7 ,e + � � • �- L_:.) ' EXIT #3 136" OF EGRESS WIDTH ,I.■.■ I rI- I I � SANITARY VENT l'007 / \ EXIT #4 136" OF EGRESS WIDTH A I J i 1 EXIT #5 204" OF EGRESS WIDTH DOMESTIC WATER LINE r �� I �i TOTAL 1,218" OF EGRESS WIDTH0 0" .--- -- Record ' J � I , Architect/ Engineers of -_� ■ I_ - f u'; �I j TOTAL FLOOR AREA 122169.5C IINV LOCATION OF NEW �/ !� I' ' LENS CRAFTERS PAD I i .. i� l CORTLAND 955 S.F. er / I i ^, I TOTAL SELLING AREA 110493.9 !I BUILDING RE UIREMENT AREA 5981.5/ I � MORGAN 0 ARCHITECT 14lir SALES SUPPORT AREA 5694.1 - L 711 N. FIELDER RD. CD ��� � PE'' " IT ill MI I I II li� SII' n n 1_ F� ARLINGTON, TX 76D12 PH: (817) 635-5696 `I NAME FS FR ST TOTAL FAX: (817) 635-5699 Seal \ I WOMEN'S SPORTSWEAR 6339.0 0.0 0.0 6339.0 � . \ / I 5y' 1,\ IMPULSE 7709.1 0.0 0.0 7709.1 1 - 1I \ CASUAL SPORTSWEAR 10089.1 0.0 0.0 10089.1 ,� � CORTLt N is „ �I ?7 - PETITES SPORTSWEAR 4267.4 0.0 0.0 4267.4 r.,T 1545.9 ! F IMPULSE BEAUTY 1545.9 0.0 0.0 ARLINGTON TEX �/ 111 -II HEl MSTYLE 6316.8 0.0 0.0 6316.8 I I I--- FASHION JEWELRY 2190.9 0.0 0.0 2190.91-4G(d\--5`'"` J SILVER JEWELRY 664.7 0.0 0.0 664.7 i imil ''` , FINE WATCHES 303.9 0.0 0.0 303.9 Architect/Engineer Job No.: / \ �L_ FASHION WATCHES 1219.7 0.0 0.0 1219.7 FINE JEWELRY 1484.6 0.0 0.0 1484.6 Nextore Store Design Revision No.: � INTIMATE APPAREL 7309.2 821.9 0.0 8131.1 0 �,___c' \ " -;_ o o + REV 0.0 I FINISH LINE 919.$ 0.0 0.0 919.8 I ! ] , I `-II / II COLOR/TREATMENT 7635.1 0.0 0.0 7635.1 LOCATION OF ELECTRIC Nextore project / , WOMEN'S SHOES 6194.8 0.0 3561.5 9756.3 Number 74095 ROOM -PANEL R2 4 4 E SUNGLASS HUT 613.5 0.0 0.0 613.5 LensCrafters Design Type: YPe: '; ACTIVE 2844.1 0.0 0.0 2844.1 GLOBAL I r RTW COLLECTIONS 8347.9 0.0 0.0 8347.9 E -.1 \\\ / • II SFOR: ,�., b. CAREER SPORTSWEAR 3195.2 0.0 0.0 3195.21ISClient UED Review ❑LL Approval 3 7 E D �...... HLA , C El C isi 0 LII L SUITS 1642.8 0.0 0.0 1642,$ ❑DOB Permit ❑Bid �P �_ \ DRESSES 3641.9 0.0 0.0 3641.9 ©DOB Permit Re Submit ❑construction \ _ lIi COATS/SWIM 3458.6 0.0 0.0 3458.6 Title Ir T _ _II.3 �1 \� / I ' -1N UP DRESS ACCESSORIES 438.7 0.0 0.0 438.7 EX. MACYS !► ► II N i FIRST FLOOR/ .� _ _ _ f - I= Illif Imo. HOSIERY 1125.9 0.0 0.0 1125.9 - , 1pa i` = FRAGRANCES 3317.8 0.0 0.0 3317.8 rte ' I� �� �■ EGRESS PLAN 0 i I 7 ' _ __ e HANDBAGS SLG 7151.3 0.0 0.0 7151.3 , . ■ - Sheet V\i/ \A/Pi: �� / Date ee PLAN NORTH / (2) PAIR 36" DOOR READY TO WEAR 0.0 4$34.9 1013.3 5848.21i-2-16 EXIT #5 ,(♦ \ '- 136" OF EGRESS CENTERCORE 0.0 0.0 294.6 294.6 Drawn y 1� -- (EX)WOMENS (3) PAIR 36' DOOR MACY'S FIRST FLOOR/EGRESS PLAN RESTROOMS STAFF V100 EXIT #4 Checked By 1 ACTUAL CAD AREA: 122169.5 S.F. 204" OF EGRESS � ',CALL :nf'_��-n° • � _ CM . ...„,,,,,,,.„..„..„,„2.:::::.:::.„,„„,:.:,„,:„:;„:,,„,:::.:::::::::..-....-,:.,--..: ..--,,,,,,,w,:,Nivo,,400:::",,vigmotoRioo..."-.77::...:::::,:::t....›...:wompo..:00$:,,,geraNiwitimmow_.41,ommote Ann NDcRDRE :, .:,,,. :,..:.,:H...,,,.. . . . .'MEWM....4.4.t.A„—\\vmpop4pw•::,,,:,:, ::,RE,i.,,.. ::-„, :: . _ .,..tiltipr.,:il :, a m-,, ,,,,.., .„0-0,,,, ,:. 0:,,oi.evew,..„0:tvommoommerskamt(4..,,,,,,,,,,,,,,,,,,,, •OU0 Lwalt.a Place.Masan.OH 4504) .•:;5:3,-c ( 1'-6' •6C,eameryemok.Last Granby,CT0601c •-:d>a,'C :'_: / #4 BARS @ 12" O.C. / DOWEL IN REBAR SET IN EPDXY TAPE SEAM STC) RE #8753 CO • 4 NEW CONCRETE 4" NEW VAPOR BARRIER Washington Square ](� SW �h! 11" 104" OVERLAP / ALIGN300 VVaS IIS tO(� Square Rd. EX.VAPOR BARRIER V.I.F.V.i.F. �EX. SLAB Tigard, OR 97223 t L.0 AREAI _ W \ A ` A A Construction for: II ~� 1 IIP -414t \- -- • - - >\\/\ , 4 , /\\7/\\\///\ EXISTING COMPACTED O ' /.\\\ \ 1, ER/LAP ////\\\ \ /1/:\ � OV• 'LAP\ /�\ SUB-GRADE CLCDQ , J \ / \ \ / \ / \ C�DdDUI PER Z \ /� / W ( � ELECTRICAL DWGS 0 0 *C GC RESPONSIBLE TO SPEAK, ON-SITE,WITH MACY'S 1-LCM17-AD100-REV00 >, OPERATIONS MANAGER TO , r;. ,iiiiiIMUMEMENHimm0::;::..:Amilililiktigi.i'.X • LI.- O VERIFY EXTENTS OF DEMOLITION, PRIOR TO THE :, i' ;\ • Cx 0 0 J REMOVAL OF ANY WALLS, . . . ... .. ; ..F. ,. ,,, . 3 ! FLOORING,ETC. TEMPORARYBARRICADE N. s' • TEMPORARY BARRICADE SHALL BE CONSTRUCTED PER T_I EXIST.CEIL. 0 Cc::: .. <C, cI LL REQUIREMENTS te--+ Q) Cc ' II • TEMPORARY BARRICADE IS TO BE 100%COMPLETE U �QC9 AND READY FOR GRAPHICS TO BE INSTALLED NO MORE 1 03 THAN(2)DAYS AFTER CONSTRUCTION START.G.C.TO 0 0) CONTACT OWNER S REPRESENTATIVE UPON COMPLETION _Q TO COORDINATE GRAPHICS INSTALLATION.TEMPORARY CLEAR PLASTIC >i I3} FE BARRICADE MUST BE PRIMED AND PAINTED WITH(2)COATS OF EITHER EGGSHELL OR SEMI-GLOSS FINISH ONLY, OR FIRE RATED - > D • GC IS RESPONSIBLE FOR MAINTAINING BARRICADE TARP AS REQUIRED --.11:7,_ p Z 0 DURING CONSTRUCTION. I • REMOVE BARRICADE WHEN 100%OF STOREFRONT OR v JOB l5 COMPLETED ON THE EVENING BEFORE G.C.'SZ °PUNCHHST IS COMPLETED,PRIOR TO OWNER VERIFICATION, �, } rI • AND AFTER LL APPROVAL IS RECEIVED.CARE IS TO BE TAKEN 41(c) l� WHEN DISSEMBLING AND REMOVING BARRICADE,ON C D f®'m INTERIOR SIDE(STORE SIDE),PAPER WINDOWS WITH WHITE Q 0 if ) 6'_S' CONSTRUCTION PAPER OVER GLAZING ONLY.TRIM 1/2'OFF j111 U EDGES AND TAPE CONTINUOUSLY AROUND PERIMETER WITH WHITE TAPE.G.C.IS TO RESTORE NEUTRAL PIER(S),MALL FLOORING&BULKHEAD TO A LIKE NEW CONDITION AND 03 FINISH WHERE APPLICABLE. 3 5/8"x 20 GA. METAL \ \ STUDS AT 24"O.C.w/ O ® \ 1/2"GWB(1)SIDE TO 4'-0"A.F.F.;GC TO PAINT I d \ \\\ o STORE SIDE WHITE, z LEVEL 3 FINISH. o \\ �' u 24" °, Et Z cc \\\ o o 3 i"X 25 GA METAL STUD z Revisions: \ \ Q DIAGONAL BRACING 0 \ i @ 48"O.C. Mark Date By \\\ 12-2-16 STAFF \\\ V WEIGHT . a"R 40895 REVIEW SET T PLYWOOD /1 0 \ jet I� ,",,, ,a,.,,,,���,"„„„„ni,wiui,n��I,tnr,�e�1n„ru�wi�,d,�uu,��„��mnnn,��„��u,nw .. - - i A 1 I.. 1 .1" \ 2'-0" AT CARPET: AT TILE: L 3 a"X 25'GA METAL TRACK 3i"X 25 GA METAL TRACK Q SECURED TO 3/4"PLYWOOD W/SCREWS©48"O.C.; SECURE TO FLOOR WITH CONCRETE SCREWS PROVIDE WEIGHT(MULTIPLE SAND BAGS SPACED)AS @ 48"O.C. IN GROUT JOINTS. PATCH AND /� N < REQUIRED FOR TEMP WALL STABILITY. REPAIR GROUT JOINTS UPON REMOVAL. / Q n 2 LCM17 AD100 REV00 UWALL. TYPE LEGEND '; : I,,N,,,,P:,::,i,,i,„,,Ew,„„,,,,:,,,,._,.„l,,,,,,,',:,,4„,,'„,",,,,,,:.',..'.',,'",rr,..,._".::/,.A..,ta%,'',',,,'M',''„,r•„,i'..,w.,,',„'„:',,'„„itV,,,„.•",4„,,,,,a,..,4:w,:i,,.§i,i§ieiv,n:aV..a.::.0W:mn0w.\w\,,N:-..*.,R,,4z/E*i.;giI:afflnii:.,ni:„ii:„iKiNl:kn:ei4Etft0':/.:V1/:\•‘.\,,' . ” — CENTER LINE GENERAL:G.C.TO FIELD VERIFY IF ANY EXISTING STORE FIXTURES ARE WITH-IN THE LIMITS OF THE LENS CRAFTERS AREA.COORDINATE WITH MACY'S FACILITIES I REPRESENTATIVES AND HAVE REMOVED. Architect/ Engineer of Record • PROPOSED LENSCRAFTER'S AREA: ' ' ' LEASE LINE 1, EXISTING AREA T-0 REMAIN INCLUDING ALL FIXTURES, FINSH ILS, FLOORING, LTC. _ CONSTRUCTION TO BE 2. EXISTING PARTITION TO REMAIN ALONG WITI I DOOR, FRAME,AND-f4ARPWARL. DEMOLISHED 3. EXISTING CARPET AND WALL BASE IN PROPOSED LENS CRAFTER'S AREA LIMITS TO BE REMOVED BACK TO CONCRETE SLAB.CLEAN,SCRAPE,AND REMOVE ALL o a ADHESIVES AS REQUIRED FOR NEW FLOOR INSTALLATION.COORDINATE WITH MFG REQUIREMENTS FOR NEW FLOORING PREP REQUIREMENTS. C 1%M ,,, Ice u BARRICADE 4, EXISTING MACY'S TILE FLOORING TO REMAIN. CORTLAND - 5. EXISTING CARPETING TO DE PEMOVED FROM ADJACENT MACY'S AREA.COORDINATE CN SITE WITI I MACY'S RCPRE5CNTAffi 'C FOR EXACT-DIMENSIONS AND EXISTING WALLS TO REMAIN TIMING SO ILDULL OF DEMOLITION. M 0 R Ci A N 6. EXISTING MACY'S WOOD PLANK FLOORING TO REMAIN. ARCHITECT . .• • " ° EXISTING MASONRY WALLS TO 7. EXISTING PARTITIONS, DOORS,AND HARDWARE TO BE REMOVED WHERE INDICATED.ANY EXISTING ELECTRICAL TO BE REMOVED BACK TO NEAREST J-BOX AND _ REMAIN MADE SAFE. 711 N. FIELDER RD. 3-LCM17-AD100-REVOD 8. EXISTING MILLWORK DIVIDERS TO BE REMOVED. PH:ARLIN(817)GTON, TX 760126 (817) 635-5696 9. REMOVE EXISTING SLATWALL,FIXTURES AND I IARDWARE AS INDICATED.PATO!I, REPAIR,AND PROVIDE JEW VENEER LAYER OF S/GYP. DD.TO ENSURE A SMOOT I FAX: (817) 635-5699 AND FLAT SURFACE(LEVEL 4 FINIS I). 10. REMOVE SECTION OF EXISTING DISPLAY AREA ALUMI JUM FRAMING AND GLASS AS INDICATED.NOTE:COORDINATE WITI I MACY'S REPRESENTATIVE AND APPLY Seal TEMPORARY CONSTRUCTION FILM TO REMAINING DISPLAY GLASS AS REQUIP.ED. 11. EXISTING MACY'S COURTESY PHONE TO BE REMOVED,ALL ELECTRICAL TO BE REMOVED BACK TO POINT OF SERVICE AND MADE SAFE.RETURN PHONE AND ALL e{ ACCESSORIES TO MACY'S REPRESENTATIVE. r FLOOR00 TRENCHING: -' r • 12, OUTLINE OF PROPOSED ELECTRICAL TRENCHES REQUIRED FOR IN FLOOR ELECTRICAL,SEE ELECTRICAL DRAWING SHEET E100 FOR EXACT LOCATIONS OF CORTLAND M ' 'NI C , ELECTRICAL BOX LOCATIONS.PATCH AND REPAIR CONCRETE SLAB SEE DETAIL THIS SHEET. 0 b,,,,1 BARRICADE: ARLINGTON,TEXAS ,`,* 13.G.C.TO PROVIDE TEMP CONSTRUCTION BARRICADE.G.C.TO FIELD DETERMINE EXACT CONFIGURATION OF BARRICADE AS NECESSARY TO COMPLETE THE OVERALL .* SCOPE OF WORK.COORDINATE LOCATION OF A 3' OPENING FOR ACCESS.WITH MACY'S AND NEXTORE REPRESENTITIVES. G.C.IS TO PROTECT THE EXISTING '] FLOORING ON BOTH SIDES OF THE BARRICADE.SEE TYPICAL DETAIL THIS SHEETG.. `) DUST BARRIER: j 14. G.C.TO PROVIDE DUST BARRIER(FLAME RETARDANT POLY TARP HEAVY DUTY)MEETING THE FIRE RESISTANCE REQUIREMENTS OF NFPA 241,SEE DETAIL THIS SHEET. Architect/Engineer Job No.: 4-LCM17-AD100-REV00 A ,. a.:.,s„ , r .u' Nextore Store Design Revision No.: A. THE G.0 SHALL TAKE ALL NECESSARY PRECAUTIONS REV ©.Q TO ENSURE THE SAFETY OF THE PUBLIC AND/OR I. IN ACCORDANCE WITH THE DRAWINGS,THOSE ITEMS WHICH ARE REMOVED,AND ARE NOT WORKMEN ON THE JOB AND TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON ON,ABOUT,OR RELOCATED OR REUSED, SHALL BE DISPOSED OF BY THE G.C. ADJACENT TO THE PREMISES. THE G.C.SHALL COMPLY WITH ALL LAWS,ORDINANCES,CODES,RULES AND REGULATIONS RELATIVE TO SAFETY AND THE PREVENTION OF ACCIDENTS. J. ANY EXISTING DOORS AND FRAMES TO BE REMOVED UNLESS NOTED OTHERWISE ON PLANS;REFER TO Nextore project DOOR SCHEDULE, Number 74095 B. THIS DEMOLITION PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET OF WORKING DRAWINGS. DO NOT REMOVE OR DEMOLISH ANYTHING WITHOUT VERIFYING AND COORDINATING K. ANY EXISTING RECEPTACLES TO REMAIN UNLESS NOTED OTHERWISE ON PLANS; REFER TO ELECTRICAL Lenstrafters Design Type: WITH ALL GENERAL TRADES AS TO HOW THEY RELATE TO THE OVERALL PROJECT. DRAWINGS. GLOBAL C. THE G.C.SHALL BE RESPONSIBLE FOR REMOVING OR DEMOLISHING EXISTING CONSTRUCTION WHICH L. REMOVE ALL WALL VINYL FROM WALLS(AS REQUIRED)AND PREP WALLS FOR NEW FINISHES. WILL INTERFERE WITH THEIR NEW WORK AND ANY TEMPORARY BRACING OR PERMANENT SUPPORT ISSUED FOR: STRUCTURES. M. G.C.TO INSPECT ALL EXISTING WALLS TO REMAIN AND ENSURE THAT THEY ARE UP TO CURRENT IZIClient Review 0 LL Approval SPECIFICATIONS. ❑DOB Permit 0 Bid D. WHEN EXISTING ELECTRICAL SERVICE, POWER,AND LIGHTING IS REMOVED, STUB BACK AND CAP AS { REQUIRED IN AREAS BETWEEN EXISTING CONDITIONS AND NEW WORK ❑DOB Permit-Re-Submit 0 Construction N G.C.TO PROVIDE AND INSTALL TEMPORARY BARRICADE PER DETAIL.SUBJECT TO CHANGE PER MACY'S \ E. REMOVE EXISTING FLOORING MATERIAL,CAP EXISTING MECHANICAL, PLUMBING AND ELECTRICAL REQUIREMENTS.GC TO ITEMIZE COST OF BARRICADE. Title SERVICES FLUSH WITH EXISTING SLAB AS REQUIRED,TYPICAL THROUGHOUT;REFER TO RESPONSIBILITY EXISTING SCHEDULE ON SHEET G002 FOR FLOORING PREPARATION. 15'-1044” D. PRIOR TO INSTALLATION OF NEW FLOOR,GC TO VERIFY EXISTING FLOOR CONDITIONS MEETS AND ARE • F. AT THE G.C.'S OPTION,DEMOLISH OR REMOVE MORE OR LESS EXISTING WORK, PROVIDED THAT SUCH IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL FLOOR PLARI / L.C.AREA VARIATION WILL EXPEDITE THE PROJECT AND NOT INCREASE THE EXPENSE TO THE OWNER OR OF AMERICA.IF THERE ARE ISSUES OR DEFICIENCIES,CONTACT NEXTORE PROJECT MANAGER PRIOR TO VIOLATE ANY CODES. THESE OPTIONS SHALL BE SUBJECT TO THE NEXTORE'S PROJECT MANAGER'S INSTALLATION. DEMO APPROVAL. G. COORDINATE ANY SYSTEMS SHUTDOWNS WITH LANDLORD&INCLUDE COSTS OF SHUTDOWN IN THE Date Sheet BID. 12-2-16 l EXISTING FLOOR PLAN / DEMOLITION Drawn By H. EXCEPT A5 NOTED,G.C.SHALL INCLUDE COSTS TO CUT, PATCH AND/OR REPAIR EXISTING WORK AND STAFF A D l00 EXISTING FACILITIES WHICH MAY BE DISTURBED DURING INSTALLATION OF NEW WORK IN BID e SCALE: 1/4 =1'-0' PACKAGES. Checked By 5-LCM17-AD100-REV00 C M . NEN -IDRE ,„„, - " O •4`470 WxatGca Place.Mason.OH 45040 •'1(513)765-0000 •g Creamery EroOlr.las:GFant,y.CT 06125 •.1,5103932484 EX/DM Li STORE #8753 I --I EX/X1‘- i `X) EQ Washington Square 9300 SW Washington Square Rd. �• Tigard, OR 97223 II 1 0- —. I � =. - • Construction for: - --' _ — A '' EX/DM a G �� . I • 1 0 . X'AM 'V J I . 0 Q� Ex„,.. � [� � Cr) �0 eOO LD . ,, ExirLM >. 1 -_, r V O • 0 0 IIIIIM X o • I - < J 43 Ink} / EX AM EX/DM = v i j VMEE i Ivo 1 _ C) • ., A 10) ir ill11 E . . FM Q.1: Alr z .Lna5 -..Ro, Ep. — All A al; a • IH 0 411( Q C' 12 "� a SP 1111_ (13 EXAM ini V 73- . i ,./. III. Ilk ' fOr ' , <Ex) A EX/AM EX/DM ill . '••• I r ��� EX/TM Revisions: Mark Date By 1011 1 12-2-16 STAFF : oloi e- I • o X/AM --_I- — X/AM , i' 90%REVIEW SET ' ` A IA 1111 . QI A Mil . III FX/AM E AM • 0,004 e Architect/ Engineer of Record API, Min 47;i4E:1,:iiii!!!!!!!!!r'',/.4,/'7,44k.: VE:\ ---'...- ''''.v ' ' . ''''. - ' - — ' k ' ' ---- W- k .\. • . • ' •• - ''' ' * ''' --- C kV :,, i lei \r,-�� ", /r 4 n 00 EXISTING MACY'S AREA. EX/DM I1. EXISTING MACY'S CEILINGS TO REMAIN INCLUDING,GYP.BD.CEILINGS,ALL LIGHTING, AUDIO SPEAKERS,AND CORTLAND 7/ 0 HVAC DIFFUSERS TO REMAIN UNLESS OTHERWISE NOTED. MORGAN EX/DM PROPOSED LENSCRAFTER`S AREA: ARCHITECT X/AM FX/AM 2. EXISTING DRYWALL CEILINGS TO REMAIN ALONG WITH ALL LIGHTING FIXTURES AND HVAC DIFFUSERS UNLESS NOTED OTHERWISE.CLEAN AND RELAMP EXISTING FIXTURES AS REQUIRED. 711 N. FIELDER RD. • I _ EX/DM 3 iR[MOVC EXISTING RECESSED DOWNLIGI+T AS INDICATED,RETUR J AX:FIXTURE TO MACY'S ARLINGTON, TX 76012 REPRESENTATIVE.ALL ELECTRICAL TO BE REMOVED BACK TO NEAREST J BOX AND MADE SAIL. (817) 635-56996 FAX: (817) 635-5699 A 4. •REMOV[EXISTING SPEAKER AS INDICATED.SAVE FIXTURE FOR RELOCATION AS REQUIRED. COORDINATE WITI I REELECTED CEILING PLAN SI ICCT A102 FOR DETAILS. Seal 49.11r_ D O S. REMOVE SECTIONS OF EXISTING BACK LIT MILLWORK TYPE VALANCE ALONG WITH ALL LIGHT FIXTURES 4., ,4- AS INDICATED.ALL ELECTRICAL IS TO BE REMOVED BACK TO NEAREST J-BOX AND MADE SAFE.RETURN r' I EX/DM LIGHTING FIXTURES TO MACY'S REPRESENTATIVE. �` 6. EXISTING AREA OF SUSPENDED ACT. CEILING TO BE REMOVED AS INDICATED INCLUDING ALL LIGHT Cc FIXTURES,SPRINKLER HEADS, DIFFUSERS, ETC. EXISTING GYP BD.SUSPENDED GRID TO REMAIN. • EX/AM _ Ex/AM ALL FIXTURES TO BE RETURNED TO MACY'S REPRESENTATIVE.ALL ELECTRICAL TO BE REMOVED BACK 6% • .1 -I CEO) TO NEAREST J-BOX AND MADE SAFE. AREAS OF GYP.CEILINGS TO BE REMOVED IS SHOWN HATCHED. t.. ARLINGTON,TEXAS 14. I I 0° 7. REMOVE LIG!IT EIXTURCS. FIXTURE TO BE RELOCATED- SEE CEILING PLAN Sl ICET A102 FOR NEW )2)1'5 r)r� �va r - LOCATIONS. { , , $. REMOVE AREAS OL EXISTING GYP. DD.SOFFIT DROPS AND ANY ASSOCIATED LIG! TING.kREMOVE Op o �`a•�' r • ;"rill Ex© ELECTRICAL BACK TO POINT OF SERVICE. 9. EXISTING TRACK AND LIGHT FIXTURES TO BE REMOVED AS INDICATED-ALL FIXTURES TO BE RETURNED Architect/Engineer Job No.: ° I TO MACY'S REPRESENTATIVE.ALL ELECTRICAL TO BE REMOVED BACK TO NEAREST J BOX AND MADE a /Fry— SAFE. ..1 : --- Nextore Store Design Revision No.: - f" 1-LCM17-AD200-REVO0 I _ REV 0.4 • i--. ��% '����� c,>; 2 Vic,', .� `?;�" ''k3 V„ y,w N .'.k+ �I `xlAM EX/AM •,:<- G ���'` Z� � ;�. . ��<I`'zc: T �E �!;�r Nextore project # _ _ `Wa �... .. a�I *. Win" � ,� �,r.,�_.,, Number 74095 `►der Iii LensCrafters Design Type: ripplird ar7n l;FX/AM EXISTING RECESSED 2 X 2 WITH LED PANEL Q EXISTING SPRINKLER HEADS GLOBAL ISSUED FOR: ., ,_. ❑Client Review ❑LL Approval 4 irr,410, ' A —• LX/TM:. 1 '' , Ail : 1 LIGHTING TRACK WITH TRACK HEAD CED LAMP z EXISTING SPRINKLER HEADS TO BE RELOCATED ❑DOB Permit ❑Bid ❑DOB Permit-Re-submit ❑Construction 71, ,Ex!DM EXISTING RECESSED DOWN LIGHTING Title ,�� -� EXISTING SUPPLY AIR DIFFUSER TO REMAIN EXISTING CEILING Iii Ex/AM EX/AMEx1AM Ex/XM EXISTING EXIT LIGHT FIXTURE W/90 MIN BATTERY P LAN / DEMO a I I // EXISTING RETURN AIR REGISTER TO REMAIN Date Sheet 12-2-16 Drawn By r EXISTING CEILING PLAN / DEMO 2 LCM17 AD200 REVOO STAFF AD200 Checked By SCALE: 1/4'=1'-0' CM , . NE)(11DRE /:,;,,\ /,..\\ ++++++ ♦ ._ .♦♦...._ •40®1u on ca Place.Mason,OH 45040 ••1(513)765-5000 J 4 Creamery brook..East Granby.Ci 0502e ••I{S 16)393-2..3. II — STORE #5753 II 9300SWWaingtonSuareRd,\,/ \/ ���►• Tigard, O R 97223 C i ' 4"X 10"STEEL�r :• Construction for. ____...._•_.._..� --- -- ..........--- ---- I ��♦+♦ i ♦♦+♦• +♦ 4"X 10"STEEL BEAM Q 0 s; f 3 co ,•'•�♦•• � tJLn • i ii-0 SPRINKLER FEED.1r 'Tear F O @ 14°-11 1/2'A.F.F. ��+ ,. O 7 . , +♦'Ir Ham'–' .... >---. X 0 0 ♦♦♦♦�♦ +♦+♦+I+41 BOTTOM OF DECK .�* •WASTE VENT +♦+♦.A _17'-6"A.F.F. 4- ' 'El.-)) 0 . ® — 1 44,4,40 — UL45?-,23 IJ10 "X 30"STEL ' ��►.♦♦ CD vr• j 4, i \ ra •_,=, 1i"0 SPRINKL � 4i + -(3:-: sv. e @14' 11102" +., ,+4,4 Z - O� -...►+♦♦♦♦♦+1 < o * - S"ROOF J i 040, 441 i+♦'♦+♦+*� .` DRAIN LI ♦+++++++. ¢ ¢ co CO ♦♦♦♦+ co ROOF DRAIN I- V+♦++44 1- THROUGH• DECK �+++ ++:+1 N N x +..a. . Q ++++ Revisions: . �►�►♦♦Al • ++ Mark Date By + ++: A. ^ 12-2-16 STAFF ♦+++� + 90%%REVIEW SET ♦♦♦♦♦ 41. } ® • ♦*f+a ++ ♦♦4 Allk 1 "O SPRINKL ^ Q0;++, V° A@ 14'41 1/2" •'47 .. 4. O 1"WATER UNE-3.- • 1 ..♦. -1 ��:•�►* 4 • Architect/ Engineer of Record — € ♦++jam a C 1D "X30"STEE'�, +��I + . • C 11V •< 0� �++♦ 1.. . •. � •� --- ., : • O R LA N • 1 ,0�RINKL * ,� ♦� @ 14'-11 1/2 ;.44 4. 1 + MORGAN• '�+�+�+�♦li♦N0----r • •••••+♦'♦'♦'♦'♦�►♦'♦'i'♦�♦ ARCHITECT + +♦i�l►♦♦ ►++i►♦+♦♦♦+♦♦•♦+♦♦♦+♦♦�,,►♦♦♦+♦♦♦� • ' i ++++.++++++♦+♦++++++++++♦++♦++++++++++++♦.♦++♦+`+.+♦+♦.♦+ 711 T ,FIELDER 60. ARLINGTON, TX 76012 • i +++ +`+++.+++++♦+++++ +.++++ PH: (817j 635-5696 i •: FAX: (817) 635-5699 r ♦ Seal + 4• ?, L. '"}ll BOTTOM OF DECK 1 nt, a • 17'-6"A.F.F. ► ;` I. t,„24 CCULANOi, v 1, ARUNG ON,TE>:; • ' y Q 1 i"O SPRINKLER FEED11 • @ 14'-11 1!2"A.F.F. 4F /' °• „4 4 Architect/Engineer Job No.: V . • ~ Nextore Store Design Revision No.: x REV 0.0 • n-i Nextore project A (� Number 74095 I KEY N OT S �/ LensCrafters Design Type: • • 12,••0 SPRINKLER FEED GLOBAL ©14'-11 1/2'A.F.F. ! 1.) EXIISTING CONDITIONS ABOVE CEILING ARE SHOWN FOR INFORMATION ONLY. v •� -- __— Y — -.-...... ISSUED Client Ve�R:w ❑LL Approval ® — • I - 10}'X 30"STEEL BEAM ❑DOB Permit ❑Bid jR ❑DOB Permit-Re-Submit 0 Construction -.. __N:._::::_-:I ... Title ri . EXISTING • ABOVE CEILING I CONDITIONS Date Sheet PLAN NORTH • 12-2-16 - EXISTING ABOVE CEILING PLAN Drawn By STAFF AD300 SCALE; 1i4"=1-0' Checked By CM • . ._ ..... ..._ . . _ . .• \y/ ..,,v NEx-FoRE /\ /,..\ W •4000 Luxottica Place,Maven,OH 45040 •+1(513)765-6000 •6 Creamery 9rook,Ear Granby,CT 06026 ••1(516)393-243,1 STORE #8753 \\/ 3 Washington Square 11' 10 " . 9300 SW Washington Square Rd. 4 Tigard, OR 97223 L.C.AREA ,, _ i . .7 1 , 1 Construction for: F . _.. .; .[1 �70Q 9.1k. GS-PW9'A• I `-`' '� - EiTT \\, ..., : ._ ,. ... , . .. ,. , , .... : _,. , » ,� E .. . ,, u� . : ... � x�x FIXTURE FLOOD PLAN SCHEDULE «,,,,. ALL FIXTURE DII 1111EN5IONAL DATA - .'::: ::i __ , A200- 5"-g" 7-4„ 7,- " 7'-4" EQUIPMENT # DESCRIPTION BLOCKING v \ T'I j I f EQ6I LENSOMETER(MANUAL} _ t EQ6A LENSOMETER(AUTO) a \ Q II � 1 1 I , iI c� II. II vD r, (_1 j ` �J -EQ8C FRAME TRACER CZ I • ` I ' - C EQ21 EYE NET STATION © O ,Cf) j€� 0833-0D 0834-00 0835-00 0836-00 EQZZA FRAME WARMER(HOT AIR) f,.I..� 5" 2-1" 31„4 15., EQ100A SINGLE POWER TABLE (3 O 2 4' 0" 2'-0" l'-6'' EQ1000 TRIPLE POWER TABLE c6 _C • \ 4 '' '� ,' EQ101 TONOMETER • m-100\ ' - „�� rc�a, EQ102 AUTO REFRACTOMETER 0 // ,-H t �EQ105C FIELDS TESTER X C) ,-. t U 0 • 04'i-i,3 r-+ _ rl 0451-DO EQ108 PATIENT CHAIR J CO .H'• \\I '' yD ` �,\, 0440-00 0420 20 EQ1096 REFRACTION STAND N. j ,.; C' EQ112 STOOL - Q) N. N. } — i., : — —F9 3-° EQ118C CHAIR MOVER a V (•-) Q--) a �y �8y (13 EQ119 LCD SCREEN du cuNC PROVIDED �+- I I INSTALLED EV G C O �n EQ120 OPTOS -o -� �� ���t Li r,1 - 0186-00 EQ121 OPTOS TABLE - ,3 E.-- E 37'1 -:iI- vv0 0450-00 EQ122 REFRACTION ROOM CHAIR -' C. LOr4 59 \ EQ122C REFRACTION ROOM CHAIR(CALIFORNIA) BLOC, h vhowa€oANo a CHART HOLDER CHART HOLDER(WALL MOUNTED) INSTALLED GC. J O 1. k SK3 SINK Z 171 O +- 3' 6" • SK7 SINK ® ) 'll-) z a o L___!,- FURNITURE # DESCRIPTION BLOCKINGco • oGS-FNO7 STOOLS FOR SELECT TABLEimJ u ., •• \ GS-FNO4 LOUNGE CHAIR - 1 LCM17 A100 REV00 GS-FN08(A)(B)(C) ADJ.TASK CHAIR("A"-HARD SURF."B"-CARPET"C"-CALIFORNIA) • s ..,, :::::,:::: � • GS-FNO9 SIDE CHAIR . - J. : GS-FN09 SIDE CHAIR CALIFORNIA STORES i: , � . � : �; `�.: r , � x , ' *� NOT 1SED IN EVSRYTOR^a, f ,��w, � : � _ < 4. : RE�tw \ N ' *:: � �P MrGS FNO7 NICV :��`�.,' :�, ' � ; . � � ARCHI �„ � . T RALNOTGFOI_O ALLMNUFACTURERSAg- GS FN02(A)(B)(C) ADJ.STOOL("A" HARD SURF,"B"-CARPETCARPET"C" CALIFORNIA) , � ITEM / DESCRIPTION MFG./PHONE # MODEL #/COLO „ . ., , k _ R ALTERNATE REMARKS SUPP. INST. Revisions: A200 nDOzrD LARSENssoa633-666s MILLWORK MILLWORK DESCRIPTION BLOCKING Mark Date B *� 4 FIRE EXTINGUISHER MULTI-PURPOSE DRY KIDDE/GRACNGER PRO LINE#PRO2-STCM GLOBAL# MODULAR# y - -... (8DD}323 0620 (MP SERIES MPS,W/B 2 FOR CLASS A, B AND C FIRES GC GC GLOBAL 0801-00 CASHWRAP,LC 515 12-2-16 STAFF \ CHEMICAL TYPE:UL RATED 1-A 10-B/C,5 LB PARTS OF AMERICA BRACKET 4T307 WALL BRACKET c 3 SIMPLEHUMAN QUICK LOAD PAPER TOWEL HOLDER GS CW2DW CASHWRAP,LC SIS(REQUIRES WIRING BY GC) „ PAPER TOWEL HOLDER-WALL MOUNTED STAPLES (800)333-3330 WALL MOUNT-STAINLESS STEEL-ITEM#180969 MDL: NONE REFRACTION ROOM T GC GS-LF10 27"(H)JOJO 90%REVIEW SET - \ aEEo 1 \ 6'-4 KT1024 4 a 1 GS LF11 0300-00 35"(H)JOJO SIMPLEHUMAN TENSION ARM PAPER TOWEL HOLDER GS LF13 0920-00 FRONT DOOR FOCAL • RETAIL SALES AREA s m PAPER TOWEL HOLDER FREESTANDING STAPLES (800)333-3330 STAINLESS srEEE.ITEM#1so9n MDL# Knlsi NONE CONTACT LENS ROOM,OPTICAL STATION T T 1.3 O GS-LF20 0303-00 27"(H)ENGAGEMENT TABLE 7 100 LJJ 10G182 POLISHED CHROME DOUBLE ROBE HOOK MODEL GC GC GS-LF21 - 33"(H)ENGAGEMENT TABLE 14 - \ +../) I COAT HOOK GRAINGER 1-800-GRAINGER #Ol 94oz NONE OD ROOMS;INCLUDES MOUNTING HARDWARE CLG. HT.= 12'-0" �;� '—' E___ — GS-LF22 0302-00 ENGAGEMENT TABLE 2 n . KNAPE&VOGT(OR HEAVY DUTY STEEL STANDARD GC GC / \ "v Q WALL STANDARDS NONE REFER TO ELEV.FOR SIZE;PROVIDE BLOCKING AS REQUIRED GS PW4D 180D 00 CASHDESK OD(3)MODULES OE1�0 v , EQUAL) #KV85AN0(DOUBLE SLOT),WHITE KNAPE&VOGT(OR HEAVY DUTY W/LOCK NUT GC GC GS-PW41 1830-00 BACKWRAP OD(4)55"MONITORS \\ BRACKETS NONE LI I Q EQUAL) #KV187ANO,WHITE GS-LF42 SELECT BAR 3/4"TH.X 12"D WHITE MELAMINE FINISHED ON SHELVING RATED AT 100€es. GS-PW43 1801-00 CASHDESK OD(2)MODULES A r- u - i8� - Z_ SHELVING ALL SURFACES NONE FASTEN SHELVES TO BRACKETS(DOUBLE SLOTTED STANDARDS) GC GC GS-LF50 0321-00 CAPACITY FIXTURE ENDCAP 6.41„ GC GC GS-LF51 0320-00 CAPACITY FIXTURE,2-BAY CEILING ACCESS PANEL WIND LOCK (840)872 5625 TR AP024 24"X 24"ACCESS PANEL NONE RETAIL SALES AREA '_ GS-LF52 CAPACITY FIXTURE,3-BAY _ ,• - CABINET HANDLE DOOR BUMPER EVERBILT 1 1/8"NAIL-ON MDL.:49955-HOME DEPOT EQUAL TO COLOR BACK OF HOUSE ONLY GC GC GS-1F53 0322-00 GONDOLA MONITOR GS-LF70 0307-00 FITTING/SELECT TABLE & I ` - 2-LCM17-A100-REVOO GS-LF70A 03.06-00 FITTING-SELECT TABLE : '-' A LSO 1 I = (REQUIRES WIRING BY 08 00 GS-LF7OW FITTING/SELECT TABLEGC) �\j :,...110,.. ili.:.,.::ohi GS-LF71 D3 FITTING/CASHWRAP itl3r ._,., .`;,`!l` .,. E GS-LF71W FITTING/CASHWRAP(REQUIRES WIRING BY GC) Architect/ Engineer of Record !+ NRAN NT1,7 T .,, ;;;,,.,.; 'i, GS LF75B 0310 00 {2}MODULAR SELECT TABLEftW f f `\� XE R �`fy,;o y: ;lr-v 10- //<A„ .0.:x€ "° ;,,4 :. '.`:,:*s GS-LF75C 0311 00 (3) MODULAR SELECT TABLE - • • '• \ `, 4 A. G.C.TO REFERENCE FIXTURE CONTRACTORS SHOP DRAWINGS FOR 1. GRAPHIC PACKAGE ITEMS;REFER TO RESPONSIBILITY SCHEDULE ON G001 AND GRAPHICS SCHEDULES THIS SHEET GS-PW76A 0830-00 BACKWRAP(4)55"MONITORS 9 o INSTALLATION INSTRUCTIONS FOR ALL FIXTURES,WALL CABINETS, FOR RESPONSIBILITIES. REFER TO INTERIOR ELEVATIONS FOR MOUNTING DIMENSIONS AS APPLICABLE. G5 LF80 0309 OO WELCOME TABLEC 00-uuvu : a -, a BASE CABINETS,AND COUNTERTOPS.G.C.TO COORDINATE WITH GS-LF90 - COLUMN PANEL,WITH BRAND MENU - • '• \• \ `\\ `\ 727 -`\~\�\\\„\` ' FIXTURE CONTRACTOR TO ENSURE PROPER FIT OF ALL COMPONENTS. 2. CENTER MILLWORK/GRAPHICS ON THIS LINE. — — =15rnd-sem [lig ”' GS LF91 SERVICE TOTEM,FLOOR FIXTURE C ® R T L A N It _c\_„,',K,.. `��� -\�\�\V B. G.C.TO ENSURE FIXTURES ARE PROTECTED DURING CONSTRUCTION. 3. DOCTOR'S EQUIPMENT.REFER TO RESPONSIBILITY SCHEDULE ON G001. GS-LF9Z - EASEL FIXTURE 1 f� SJ-33-1A01 J 4. COAT HOOK AT 48"TO CENTERLINE OF HOOKS. COLUMN PANEL,WITH MIRROR M 0 R G A N G5 LF93 a GS-PW01(L) 0440-00 3"PERIMETER FIN L"=LEFT Eo0ONUPROVIDED AND CONTACT LENS O• o \ (" - } sNSTAE€vBY« kRCHITECT ROOM ' �J [D.: - 5 u C. G.C.TO PROVIDE ADEQUATE BRACING,AS REQUIRED,IN WALLS TO 5. 2A 106E FIRE EXTINGUISHERS AS DIRECTED BY THE FIRE MARSHAL.(SUGGESTED LOCATIONS ON PLAN.) rG5 PWO1(C) 0430-00 3" PERIMETER FIN('C"=CENTER) 101 • 1-.�. J SUPPORT WALL CABINETS AND FIXTURES. 6. GC TO USE PERIMETER FIXTURE DIMENSIONAL DATA(THIS PAGE)FOR PROPER WALL LENGTH. GS-PWO1(R) 0440-00 3"PERIMETER FIN("R"-RIGHT) s o \ GS PWO1A(L) 0440-00 3 1/8"PERIMETER FIN("L"=LEFT) 711 N. FIELDER RD. �,Ni D. G.C.TO FURNISH AND INSTALL LOCKSET OPERATIONAL BY TENANT 7. COORDINATE DIMENSIONS FOR MILLWORK WITH TENANTS MILLWORKER. ARLINGTON, TX 7fi01 Z CLG. HT.= 10'-0" _ • ` 'y a l GS-PWO1A(C) 0430-00 3 1/8"PERIMETER FIN("C"=CENTER) PH: (817) 635-5696 o LL 0 5 z =\I ONLY. 8. G.C.TO APPLY PRINTABLE CAULK WHERE MILLWORK COUNTERS MEETS GYP BD.WALL. GS PWOIA(R) 0440 00 3 1/8"PERIMETER FIN("R"--RIGHT) FAX: (817) 635-5699 + 8 A200 r,� u. � GS PW10 0400 00 48"(W)PERIMETER WALL UNIT 1°; a E. G.C.TO SIGN FOR PACKAGES WITH A NOTE "SUBJECT TO CONCEALED 9. INSTALL GS-PW FIXTURES SEQUENTIALLY STARTING AT THIS POINT.GC TO VERIFY ADJACENT WALL IS CLEAN, LEVEL, GS PW11 0420-00 2S"(W)PERIMETER WALL UNIT Seal �\ DAMAGES"ON IT. _ OPTICAL STATION ,. } 7 w _',� STRAIGHT AND PLUMB. GS PW30 0451 00 18"(W)MIRROR CABINET WITH STORAGE 102 I S r C • °-� F. G.C.TO REFER TO GRAPHICS STANDARD MANUAL FOR GRAPHIC GS PW31 0450-00 12'° (W)MIRROR CABINET WITH STORAGE �.� �'6 10. CL SI 1ELF 36/48 (2)3/4"TI IICK x 12" DCCT WI 1ITC MELAMINE SI ICLVCS,FINISI ICD ON ALL SIDES, FASTENED TO C' 0" CLG. HT.= 10'-0" - • I f' ; \ MOUNTING HEIGHTS,TYPICAL. GS-PW60 0831-00 BACKWRAP FEATURE -- --/ . II G. E =EXISTING TO REMAIN. TALL WI ARC DOUBLE SLOTTED STANDARDS-AND BRACKETS AT 1B"O.C. BOTTOM OF STANDARDS TO START 18"A.F.F. GS PW6D_55 0831 00 BACKWRAP W/55"DIGITAL MONITOR p ' ,• AND FIRST SITILE TO BC MDUNTCD AT 4f3"A.F.F. GS PW60_75 0834 00 BACKWRAP W/75" DIGITAL MONITOR Ti.I11�10\�.�1\ —— — \ M = EXISTING TO BE RELOCATED. i 4...." — — ��\\° •••\ ��\`1���� ,� F= FUTURE EQUIPMENT 11. DOCTOR'S CERTIFICATES/LICENSES TO BE INSTALLED AT THIS LOCATION. GS-PW61 0832-00 BACKWRAP FEATURE WITH SIGNAGE •••1 1 12. NOT USED GS-PW61_55 0832-00 BACKWRAP FEATURE W/SIGNAGE&55"DIGITAL MONITORY,: • a # N H. REFER TO ELEVATION SHEETS A200 A201 FOR ACCESSIBILITY ACCESS GS PW61_75 0835-00 BACKWRAP FEATURE W/SIGNAGE&75"DIGITAL MONITOR — 49 i SIGNAGE 13. REFER TO ELECTRIC SHEETS FOR ELECTRICAL/DATA FLOOR BOX LOCATIONS.(TYP.) GS-PW62 0833-00 BACKWRAP FEATURE WITH WOOD FRAME tcx 1 ; \; — GS PW6255 D833 00 BACKWRAP FEATURE W/SIGNAGE,PORTAL FRAME, &55' DIGITAL MONITOR ,�',)� )o' A200 10 �l 3-LCM17-A100-REV00 14. SEE ELEVATION SHEET(S)FOR LOCATION OF START AND END POINTS OF WALL FINISH.SEE SHEET A103 FOR w �lGS-PW62_75 0836-00 BACKWRAP FEATURE W/SIGNAGE,PORTAL FRAME,&75"DIGITAL MONITOR PRETEST <. ITO 1 A200 • 11 ,I FINISH SCHEDULE. GS PW$0 FILLER WITH MIRROR,NO STORAGE 103 + a a '�; *"` 15- SAfd RIfTY-i R+><P REFER TO PLUMBING AND ELECTRIC SI IEETS FOR APPLICABLE INFORMATION, GS PW81 0186 00 PORTAL VERTICAL MODULE Architect/Engineer Job No,: CLG. HT.= 10'-0" " o z \ "``* 16 HIP GS-PW82 0186-DO PORTAL HORIZONTAL MODULE 11 ; z a a -F- \1I . \` CAPACITY,CAL: J LATIO PA/OPTICIANS LICENSE TO BE INSTALLED AT THIS LOCATION. GS-PW83 - WOOD FIN VERTICAL 16 �! 1110111 GS-PW84 0460-00 CORNER FILLER I - \ FIXTURE TYPE QUANTITY CAPACITY TOTAL GS PW91 1811 00 SERVICE TOTEM,WALL MOUNTED Nextore Store Design Revision No.: sE GH CHART• 1. I 48"WALL FIXTURE 6 69 414 - •• t _ zSB -cam _ aFH� 1» �j GS-PW93 MIRROR,OVERALL SIZE MATCHES LF90/93 _ REV 0.0 , 1..-5 — i-z.. �;\��������\\��;��\��}\�`,,z. ..�--- .,•`I 24"WALL FIXTURE 2 34 68 GS-PW94 1844-00 FRAME LEDGE,26"W C . SL-CD53 SE 000 I\ ENDCAP 5 16 80 GS PW95 BOH-UP24 1846-00 FRAME LEDGE,48"W EQ6A ,`I UPPER CABINET - GS-BOHO1(L) 1842-00 WORK COUNTER FOR SIS(LEFT) Nextore project 5E-ODO€ ` 2-BAY CAPACITY 3 92 276 GS BOHO1(R) 1843-00 WORK COUNTER FOR 515(RIGHT) Number 74095 ROOM I -_ EQ112 1._,,,, TABLE GS CL02(L) 186D DO SINK BASE FOR SIS(LEFT)E 118ELensCrafters Desi n T e: i 4 13 Q _ a " 3 BAY CAPACITY 0 144 0 g YP3 104 ^ � TABLE -GS-CLO2(R) 1861-00 SINK BASE FOR SIS(RIGHT) 4 A200 14 q ` SE-CLOS 1863-00 CONTACT LENS STORAGE GLOBAL CLG. HT.= 10,-0" v _ wl��l I ENGAGEMENT 1 20 20 SE-0001(L) 1853-00 DOCTORS DESK(LEFT) 15 ��""� I\ TABLES SE-ODO1(R) 1854-00 DOCTORS DESK(RIGHT) ISSUED FOR: ) w O 3s _ wii — SE-0D02 1855-00 SINK BASE T l9 Client Review 0 LL Approval - iii i S-FNO n *II �i TOTAL 858 SE-0D03 1856 00 SINK CABINET ABOVE ❑DOB Permit ❑Bid EWA NI ` �. I ` ❑DOB Permit-Re-Submit 0 Construction 1 ��������� ��«������������"���`����`������������.... ����\����' GRAPHICS # DESCRIPTION BLOCKING •• LCI-GH-30 OD SNAP FRAMES Title 15'-104" LCM-DO-CS _ L.C.AREA 4-LCM17-A100-REVO0 LCM EE CS EYE EXAMS CABINET SIGN FIXTURE - FLOOR LCM-FW-CS FOCAL WALL CABINET SIGN _ LCM-FW-CS.1 FOCAL WALL CABINET SIGN FOR 75"DIGITAL MONITOR BACK WRAP P LAN l ' • LCM-GH-16 DOCTOR'S NAME SLAT SIGN LCM-GR-32 ROOM ID SIGNS LCM-MW-CS MAIN WALL CABINET SIGN Date Sheet FIXTURE — FLOOR PLAN 5-LCM17-A100-REV00 SE GH-23 CS 1 MAIN ALL CINET/ABCENSEIGN SNAP FRAMES 12-2-16 1..) SCALE: 1/4"--1'-0" STAFF 6-LCM17-A100-REV00 Drawn By Checked By A 10 0 CM ..._ ______ NE.4--0RE •4600 Wrottrca Pacer Nixon,OH 45040 •*1(513)765-6000 •6 Creamery Brook,East Granby,Cl 0607f •,1(416)393-2484 I \ f STORE #5753 \. 1 Washington Square 9300 SW Washington Square Rc. I- - L,C.AREA _-- t , Tigard, OR 97223 0 • Construction for: • . tm s , e is Y! Y ;l:' 1 y v '�38PJS �` -- 23 ,� 4� - �j'EYED N '� � �' \ A.. oTE O , .00i0IMIAWOMMIWINgiiir..,PH,-ARTAMEMEMEENNEMNAk Cil) „ 1. COAT HOOK PROVIDED AND INSTALLED BY GC. MOUNT AT 48"A.F.F.INTERIOR SIDE OF REFRACTION ROOM DOOR. METAL STUD WALL WITH FURRING AS DETAILED W/ PAINTED GYPSUMCD J 2. SEE ELEVATIONS FOR LOCATION OF WALL TILE FINISH. GYPSUM BOARD BOARD BOTH SIDES a \ 3. SEE ELEVATIONS FOR BASEBOARD LOCATION AND STYLE. METAL STUD WALL WITH EXIST.C.M.U.WALL r Q PAINTED GYPSUM 1�1�1 4. NEW STUB UP CONDUITS,REFER TO ELECTRICAL DRAWINGS FOR EXACT LOCATION FOR UTILITIES AND FREESTANDING BOARD BOTH SIDES METAL FRAME DOOR cc, -- ,r cfp Q • •• \ MILLWORK AND TRENCHING. I METAL FRAME DOOR , "` ' � 03 ..-- >,. . • 5. GC TO PROVIDE AND INSTALL CORNER GUARDS AT ALL BACK OF I!OUSE OUTSIDE WALL CORNERS.SEE FINISI I JAMB [ffi.4/1? •% 'RI 0 SCI IEDULE FOR MAKE AND MODEL. w DOOR:REFER DOOR EYU. +-: = s. 6. CC TO PROVIDE&INSTALL ACCESS PANEL.PAINT TO MATCI I WALL. :_jid SCHEDULE �i�/ II DDDR:REFER DOOR �y ��\ PAINTED HARDWOOD .'\� ! �. SCHEDULE < >.< tf)0 7,7 \ \ 'C 7. EXISTING PARTITION. C.C.Ttj�ATCI I/REPAIR AS REQUIRED TO MAINTAIN REQUIRED FIRE RATING. NEW C.M.U.FILL WITH - C-- { . 9 • - - - - 8. REFER TO PLUMBING DRAWINGS FOR MOUNTING OF WATER HEATER AND SPECIFICATIONS. BACKER ROD AND CD r SEALANT.PAINTED/ `` • 9. NEW ELECTRICAL DISTRIBUTION EQUIPMENT,REFER TO ELECTRICAL DRAWINGS. FINISHED TO MATCHy_ (13 C) L 10. GYP.BD. BULKHEAD ABOVE. EXISTING 0 0_ Le) 3 H ie ��- 11v. . RECESSED RECEPTACLE,COORDINATE WITH ELECTRICAL DRAWINGS. INTERIOR DDDR EXTERIOR DOOR CASED OPENING \ 12. WRAP COLUMNS AS INDICATED. 1 0 4 31°X 4( z I � � 1 ' A300 13. INFILL WALL AS REQUIRED.MATCI I ADJACENT WALL CONSTRUCTION AND RATING.PPE'WALL TO RECEIVE NEW \ FINIS'1CS. Z vI 2-LCM17-A101-REV00 -9:� o a . () 14. EXISTING PARTITIONS AND COLUMN ENCLOSURES WITH-IN LEASE AREA TO BE PATCHED AND REPAIRED UPON ALL d L1) NEW WORK TO A LEVEL 4 FINISH.(TYP) -., ::: LLI < O 15. PROVIDE NEW VENEER LAYER OF i"GYP-BD.ALONG ALL EXISTING WALLS WITH RECESSED STANDRADS.PROVIDE A 4 '2W * ilk :':::: :0: ATE CONSTRUCTIC)Nco \ LEVEL 4 FINISH TYP). w #;,, c , • • ' 16. PROVIDNGS AS SPECIFIED. DISCREPANCIEE AND INSTALL NEW PECFIED.EW PARTITIONS AS DIMENSIONED.PROVIDE AND INSTALL ALL DOORS AND/OR CASED A. pGC TO$CREPA INTAIN F HOLD DIMENS SAS SPECIFIED. NOTIFY NEXTORE PROJECT MANAGER OF ANY \ • '•\; 17. PROVIDE AND INSTALL FLOOR MOUNTED SEWAGE EJECTION PUMPS.SEE PLUMBING DRAWINGS FOR SPECIFICATIONS. B. GC IS RESPONSIBLE FOR ANY PREPARATION OF THE FLOOR SLAB AND PROCUREMENT OF MATERIALS - ti; REQUIRED AT THE PERIMETER TO PRODUCE A FLUSH CONDITION BETWEEN THE LENSCRAFTERS FLOOR 18. PROVIDE 14'"X 24"FLUSI I ACCESS P Rl'PUMP LOCATIONS.G.C.TO PAINT PANEL TO P�IATCI C AREA AND THE EXISTING AREA FLOORING SURROUNDING. SURROUNDING WALL. C. GC IS RESPONSIBLE FOR INSTALLING ALL FINISH FLOORING. GC IS ALSO RESPONSIBLE FOR ALL FINISH 19. PROVIDE 18"X 18"FLUSI I ACCESS PANELS AT SANITARY PUMP LOCATIONS.G.C.TO PAINT PANEL TO MATCI I WALL MATERIALS BEHIND AND UNDER ALL MILLWORK. - . SURROUNDING WALL. D. GC SHALL SUPPLY AND INSTALL BLOCKING IN ALL WALLS AS REQUIRED TO SUPPORT WALL SHELVING Revisions: 20. LOCATION OF HAND WASH SINKS. REFER TO PLUMBING DRAWINGS FOR SPECIFICATIONS,AND WATER HEATER AND CABINETS.ANCHOR BLOCKING W/SCREWS AT TOP MIDDLE AND BOTTOM(NO SILICONE).REFER TO Mark Date By MOUNTING OF AND SPECIFICATIONS. DWG.A200&A201 AND MILLWORK SHOP DRAWINGS FOR MOUNTING HEIGHTS. 12-2-16 STAFF `, 21. PROVIDE AND INSTALL NEW MACY'S STOCKROOM DOOR.COORDINATE WITI I MACY'S RCP RESCNTATNF FOR fINAL E. ADEQUATE ACCESS PANELS OR DOORS SHALL BE INCORPORATED INTO TENANT WORK FOR INSPECTION E DOOR LOCATION PRIOR TO CONSTRUCTION. WITH SERVICE AND RE CEON-SITETREPRESENTATIVE.OBTHLANDLORD AND TENANT EQUIPMENT,COORDINATE PLACEMENT ' 90%REVIEW SET �© RETAIL SALES AREA • 22, PROVIDE AND INSTALL NEW PAR I LION WITH RECESSED WALL STANDARDS TO MATCH EXISTING IN THE MACYS AREA. F. REFER TO SPECIFICATIONS(UNDER SEPARATE COVER)CONSTRUCTION CRITERIA MANUAL n ••t INCLUDING HEIGHT,SLOT lING AND SPACING.COORDINATE WITH MACYS FACILITIES FOR O.C.SPACING OF THE WALL @0Q 100 s \ • G.STANDARDS. NO MATERIAL SUBSTITUTIONS WILL BE PERMITTED UNLESS SUBMITTED TO NEXTORE PROJECT MANAGER CLG. HT.= 12'-0" FOR REVIEW AND APPROVAL. 23. EXISTING MACY'S WALL HEIGHT MAY BE REQUIRED TO BE EXTENDED ALLOW FOR NEW CEILING PATCH-IN.VERIFY ACTUAL HEIGHT OF PARTITION IN FIELD AND DETERMINE IF EXTENSION IS REQUIRED. H. ALL MANUFACTURERS RECOMMENDED INSTALLATION AND MAINTENANCE PROCEDURES ARE TO BE A I i FOLLOWED BY GENERAL CONTRACTOR ON THIS PROJECT. Q N k I \ 1 LCM17 A101 REV00 I. GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE REPRESENTATIVE LISTED AS SOON AS u \ - - CONTRACTS ARE AWARDED TO COMMUNICATE DESIRED SCHEDULE DATES AND PROJECT INFORMATION. AJ J. GENERAL CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL UPCHARGES ASSOCIATED WITH THE DELAY \`. ;' 4i ' .:'."` '�' i OF ORDERING SPECIFIED PRODUCTS. ` ,,., a i 1 r Irl 1Ir3I, :1. DOOR HARDWARE SCHEDULE r,_ ;,1 , ` •„Eta ENAt itisic,t,.r'.:;1''''''z , : K. ANY QUESTIONS CONCERNING THESE SPECIFICATIONS SHALL BE DIRECTED TO THE PROJECT MANAGER a;. : t` ''" ,% : v ,,., FOR DOCUMENT CLARIFICATION. b 8 ' I DESCRIPTION MFR. MDL#/COLOR ALTERNATE REMARKS CONTACT L. ALL TENANT FURNISHED ITEMS(MATERIAL AND LABOR)TO BE SCHEDULED,COORDINATED&SUPERVISED = a "CLASSROOM" BEST ACCESS SYSTEMS 93K-7 R US26D TK SCHLAGE KEY OPERATED ON OUTSIDE ONLY (3E17)849 2250 ST ACCESS BY GC. INTERIOR LOCK CORES BEST ACCESS SYSTEMS 9K SERIES NONE CONSTRUCTION CORE PROVIDED AT PUNCH ES ACCESS M. ALL DIMENSIONS ARE TO FACE OF GYP.BD.UNLESS NOTED OTHERWISE ON PLANS. (317)849-2250 N. ALL GYP.WALL BOARD TO BE FINISH LEVEL 4. CEILING GYP,TO BE LEVEL 5 FINISH. Architect/ Engineer of Record J I � 23 A300 BUTT HINGES(1-1/2 PAIR STANLEY HARDWARE FBB-179,4-1/2"x 4-1/2" WAGER HINGE CO STANLEY HARDWARE p- PER DOOR) FINISH US26D _ (800)622 4393 0. PRIOR TO INSTALLATION OF NEW FLOOR,GC TO VERIFY EXISTING FLOOR CONDITIONS MEETS AND AREI • 4'-1- 2'-58" ¢ #407-1/2"CONCAVE BROOKLINE#1326-CV NES IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL OF WALL BUMPERS NES ALUM SILVER ,CONCAVE (877)671-7011 AMERICA.IF THERE ARE ISSUES OR DEFICIENCIES,CONTACT NEXTORE PROJECT MANAGER PRIOR TO C 1M [ R.O.HOLD ¢ INSTALLATION. u FLOOR STOPS IVES #436 ALUM SILVER BROOKLINE#1330A _ _ _ _- y J SOLID CORE WOOD COMMERCIAL DOOR SEE DOOR SCHEDULE SUBSTRATE ADHESIVE TO HAVE A VOC LIMIT \ee\e\\\eee\�eeee\\eee\eo�\eee� i _ \ DOORS/ &HARDWAREgCOMMERCIAL DOOR - s�33 wo1 PL LAM DOORS FORMALDEHYDE RESINS NOC WOOD UREA- C C R T L A N C (865)429 89$0 CONTACT LENS `� HOLLOW METAL DOORS COMMERCIAL DOOR SEE DOOR SCHEDULE M 0 R G A N ROOM �"`•�/ �1 +c ; 22 &FRAMES &HARDWARE A R C H ITEC T + 101 - •i I • \ 18'"X 18"ACCESS PANEL-PAINT PER WALL .-.I ® �, ACCESS PANEL ACUDOR #Z91818SCWH EQUAL HOME DEPOT FINISH ACCESS PANEL RESIDES. 71 1 N. FIELDER RD. CLG. HT.= 10'-0" • 'j - ARLINGTON, TX 76012 15 I 3 5 LCM17 A101 REV00 4 LCMl7 A101 REV00 • A300 PH: (817) 635-5596 I \; FAX: (81 7) 635-5699 k' A300 OPTICAL STATION ;. - - - e. t �: : : ; , Seal � 16 102 I �, ..... .. : .... ...:.. :, �� � .. >: - ..� .\. ... w... ,.: , .. .... ,,... ... ,.. .. .... ,», l : ,, t , .. ..r t ... \ .. \ \\» "l 1. ::l 3.'k'� �. '� 3 3 .3"-8'' tet.,... :: .« ., : .. � t. .. �.�. �. \» ,;. �� ��� -0-..t CEG. HT.= 10'-0" •� i .� O ,,..,::, �..yi lee. FINISHED a,no \ r� ___ DOOR(FLUSH),DOOR SEE REMARKS FOR L J �+ �+ I f OPENING 1 1 NI SOLID CORE WOOD MACY'S DOOR ONLY C. ..ry Z \\� \ \ \I `� \ \ \ PAINTED PL105, FRAME \ HARDWARE IN DOOR ` •°• �I PAINTED P104. i SCHEDULE `' SOFFIT @ 10 \ SEE PLAN FOR , / (" _V 6'-10°A.F.F. I 15 ` DIRECTION OF SWING \ / DIRECTION OF SWING '.+ It'�{y 11iv I l=r.: J e� O \ r / T T102 '�{ c 0 . © T102 0 z O C) \ / ,CASED OPENING , Oa- PRETEST ` r' '4 A300 �, o = p , / CASED OPENING F-701/ _ Ou (PAINTED/P104) r / (PAINTED/P104) •16 103 - • i' Qn �_�I \/ Ah / d I!\ r i / CEG.HT.= 10'-0" • I ix3 m �,. '' I o ao N � r ® Architect/Engineer Job No.: 3"" 3" 2" S � v ° 141OLD Lel ? E' 4,, i .OrrHOLD I A300 N a, \ \ R.O. 4'-0" F.E . '_ wii Nextore Store Design Revision No.: _ __ 4 0" F.d \ Y • I i - -- 1�.\eee,\te\,e, .�\e\\e\\\\,\eae\„\\ee\e\,I : - \ MIMEO � / '\ "" �' REV o.o "r°D\ \ / \ C) - +�r II A WHEN CASED OPENING R C WHEN CASED OPENING D EXAM \ O ABUTTS WALLTILE O O ABUTTS WALL COVERING OR PAINT O � Nextore project ROOM I ,i' - 15 \' A3'`0 3-LCM17-A101-REV00 Number 74095 1 \ o LensCrafters Design Type: 16 104 \� 9 yp O - \ - " o !i :,�, -.fes : .;:, ;:\ R cr„', ,\, >-:: : :. _,- ,,< ,�_� •,,,,,A4:::::,,,,,,,. / , �_ � ,� � � ��<:�� GLOBAL n � \ ® � - � ]in-,..4-a] ] :> >,- >, ,�» ,< ,... . ::,.. .:.: . .,.>`• ,.� _ ISSUED FOR: 5 t REMARKS ®Client Review 0 LL Approval : fl ROOM NAME MARK DOORS FRAMES HARDWARE \ \ DOOR SIZE DOOR DESCRIPTION ❑DOB Permit ❑Bid \ g M\\\\Z..\\�\\\\�\tR\\\\\\�\\'\\\\.\\ NN\\\ \\S\ WI r-j� HEAD :-... . -r \ -MATERIAL FINISH LABEL JAMB DESCRIPTION CLOSER THRESHOLD STOP KICK ❑DDB Permit-Re-Submit 0 Construction I. WIDTH HEIGHT THICK TYPE CONSTRUCT COLOR FINISH GLAZING _ LABEL A300 CASED OPENING 101A 4'-0" 9'_4 5/8' A 4 _ FINISHED CASED OPENING MATERIALS BY G.C. Title II 12'-0" CASED OPENING 101C 4'-0" 9'-3 5/8" C I i HOLD `EXAM ROOM 102 3'4' 6'-8" 1 3/4" B SOLID CORE - PL105 NONE NONE HM P104 NONE 1 LEVER/CLASS RM NO NO FLR NO CONSTRUCTION 3 MACY'S 103 AS REQ, AS REQ. 1 3/4" D SOLID CORE SFE NONE NONE HM SEE NONE NO NO FLR YES DOOR HANDLE MFG.:TRILOGY MDL NO.:T2 DL 2700 IC/26D 15'404" REMARK REMARK 1 LEVEL/CLASS-RM HINGES-MFG.:STANLEY MDL NO.:FB-179(3 PER DOOR) FLOOR PLA N ( / FLUSH BOLT WHERE REQUIRED MDL.NO.:IVES 458B26D L.C.AREA GC TO VERIFY W MACY'S ON-SITE OPERATIONS FOR DOOR FINISH TO MATCH 1'� CONSTRUCTION - FLOOR PLAN ` .- - Date Sheet 12-2-16 Drawn By SCALE: iia•=l'-0' I- STAFF A101 6-LCM17-A101-REV00 I Checked By CM `. \ ,t Ex/Dm© � i n _E 1 m - •40000 Luratika Cl&e.Masan,OH 45040 •-. .7 . •6 Creamery Book,East Granby.CT 0E026 •,: - ._ *`\ w ce�x) \ 4' EX/DM �• STORE #8753 2 Washington Square 'i Ex m. SW Washington Square Rd. �. _ Tigard, OR 97223 •. . A 4, '„ • AIS 1 Construction for: . 11111 II • • JPJI . 1I EX AM •.0 . killil . Ex/DNA 1 II . �1I / ' � RILTI , : 4 IIII E� 1 ¢ � �o o lilt I , � u O >a /D 0 U\ EXAM EX/AM EXAM O O l\ IN C i C6 IgiligOIPMFIll \ w .�:. a, 'i�E; � �: �. T,E ,.:�S43184M6-:11ffill6.1"rn ,\�\�„ ��ii'r �UT�i'w'i ..,. �. (IS • \ • r c.,,,,,.,�Ct^ ..f; ,,.: � ,:': ii.::a r.�� i.,,,:r%//� x,,::.//:rf:. ::: :.,,:»:», � i/ /,: Y ,*::�, a., °"'�i:.; fz. � fa::f ;./:F`. ,��s:' U Eilik %,,:':; i_.....::.., ...`�..... ::..;: ....... .. :....//.'.,���.:,,,,,,� /rim„_ .,.. _., ._..\ ... .f.: .. : ::;. ., :.... ., :r. r,. >3`�,'.. .....�:' ,. _ ■' \ EX/DM A. EMERGENCY(EM)LUMINAIRES SHALL BE CIRCUITED WITH AN"UNSWITCHED HOT”TO PROVIDE 1. EXISTING CEILING IN THE RETAIL AREA IS THE EXISTING MACY'S CEILINGfTO REMAIN,PATCH GRID p - b I � I c; 111116 eQ) � Q—.) I. II CONTINUOUS POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF. 0Le) E 4li; INTO NEW WORK AND REPLACE ANY DAMAGED OR STAINED TILES WITH NEW TO MATCH EXISTING.. cU 0 i a \� B. ALL NIGHT-LIGHT(NL)LUMINARES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING 2. EXISTING GYP.BD.CEILING IN THE RETAIL AREA.EXISTING MACY'S CEILING TO REMAIN. { ' \ C. IT SHALL BE THE G.C'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE.THE G.C. 3. SEE SHEET A101 CONSTRUCTION FLOOR PLAN AND ELEVATIONS FOR BULKHEAD HEIGHT v , r SP O SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. 4. PRQVIDE AND INSTALL NEW 2X2 ACQUSTICAL CEILING IN THE OD AREA.SEE FINISH SCHEDULE SHEET A103. —I O • Ex/AM X/AM Ex/DM 5. EXISTING LIGHTING IN THE RETAIL AREA IS THE EXISTING MACY'S LIGHTING TO REMAIN.CLEAN ANDZ 1J)vs X D. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. I \ c) ...40( -LF,--; EXIT/EMERGENCY LIGHTS AT DOOR TO NON-SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED RELAMP. 1 i 1 <C Q v • ABOVE DOOR.IDIRECT OCATIONS ARE NOT ACCEPTABLE,IMMEDIATELY CONTACT LUXOTTICA PROJECTMANA6. INSTALL PROVIDED 2 X 2 LED LIGHTING TYPE'AD"AND"AD-EM". W cp cEx) 7. INSTALL PROVIDED SECTIONS OF TRACK"XT-S"AND LIGHTING FIXTURES TL AS SHOWN. J • E. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA,G.C.SHALL ARRANGE CIRCUITS TO AVOID THE g INSTALL PROVIDED EXIT LIGHTING TYPE"X2 USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS.THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR 1 9. EXISTING HVAC DIFFUSERS IN THE RETAIL AREA ARE EXISTING MACY'S TO REMAIN,CLEAN. \I . GRILLES OR ACCESS PANELS AS LOCATED ON PLANS.IF PLAN LOCATION IS NOT ACCEPTABLE, 10. NEW HVAC DIFFUSERS IN OD ROOMS.SEE MECHANICAL I \ IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION. > ��111E1 �� — 11117 to EwrM F H N D THE N TALLATI N FALL M NAP. AN A T AMP 11. EXISTING EMERGENCY LIGHTING IN THE RETAIL AREA TO REMAIN.FIELD VERIFY FIXTURES ON EMERGENCY G.C.'S BIDS ALL I CLU E I S O 0 LU I ES D SSOCIA EDL S FURNISHED BY f 'Lill I LLIXOTTICA.G.C.IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL DIRECTIONAL FIXTURES AFTER GENERATOR INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C.LIGHT FIXTURE SPECIFICATIONS 12. EXISTING SPEAKERS, SECURITY CAMERAS,TO REMAIN. Ex/AM EX/AM MAY VARY,IF THIS IS THE CASE,CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT Revisions: 11111 • SPECIFICATION OF LIGHTING FIXTURES.IF THE CEILING SYSTEMS ARE FIRE RATED,G.C.SHALL CLOSELY13. SPRINKLER HEADS FOR REFERENCE ONLY WHEN SHOWNMark Date By 7 I III COORDINATE FIXTURE REQUIREMENTS WITH LUXOHICA. /� 12-2-16 STAFF 11 . _ RETAIL SALES AREA \. mo cEx) G. G.C.SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. a0[%1\EwEw SEC —. 9 I "k- • 12 - 1 100 •I • • j H. G.C.SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT,FIXTURES AND MILLWORK r PRIOR TO CONNECTION. 3 CLG. HT.= 12" 0" •� C I AC-4 , L CEILING GRID SHALL BE CENTERED IN ROOM UNLESS OTHERWISE NOTED. .- ' ` .I' J. DOWN LIGHTS SHALL BE CENTERED IN TILE UNLESS OTHERWISE NOTED. A ,41 �• �I EYJAM EXAM EX/AM 1-LCM-A102-REV 0.0 2-LCM17-A102-REV00 al.I \! •` i I A III ..„.,. --- \ ' .k,.-- -- x , ♦ `, .. . .:1 8 +,.:. .v ..: : ...,... ",.................., ..„:„...,...........,.,,,,.,„,:s ■ RIA ' :::.:.: ,� � .... ,: `�.. >.....,,r,,,:!.:.„.:1-,...,,f,.,..:,,,,,,,,,,...,,,,,„:.,.... -�, :,� /: �/, ` `��:: �.� �` ': ACt1)ARI✓A'C�NLY \ .i j FOR NEW FIRE SPRINKLER SYSTEM: SYMBOL TYPE DESCRIPTION DESCRIPTION CONTRACTOR SHALL PROVIDE A COMPLETE FIRE PROTECTION SPRINKLER SYSTEM FOR THE ENTIRE SPACE IN _ ■� •_II — — — COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS AND THE LANDLORD'S CRITERIA. THE SEE ELEC.SHEETS FOR MFG, \ I CONTRACTOR SHALL HAVE DRAWINGS,SHOP DRAWINGS,APPLICATIONS AND SUBMITTALS PREPARED BY A Ti a Il - � — — � -- SPECS ETC. AD RECESSED 2X2 LED TROFFER PROPERLY LICENSED PROFESSIONAL,WHO IS APPROVED BY THE LANDLORD. ALL DRAWINGS AND Architect/ Engineer of Record YP.ALL LIGHTS IN g \ o Ex) (ex) AD (T CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL CODES, REGULATIONS,INSURANCE ASSOCIATIONS AND 0 SP 0 Q — SCHEDULE) RATING BUREAUS AND SHALL INCLUDE ALL PERMITS,TESTS,SHUT DOWN FEES AND CERTIFICATIONS TO PROVIDE ESM A COMPLETE IN PLACE SYSTEM. II AD-EM RECESSED 2X2 LED TROFFER WITH EMERGENCY BATTERY FOR EXISTING FIRE SPRINKLER SYSTEM: I. �\\\\c\�\\\\\\�a��\\\\��\\�N..� - r Y ...\\,...x..... .NN © BACKUP. .3 -YI71��N 1I\ X/AM EX/DM AD EM CONTRACTOR SHALL REWORK AND MODIFY THE SYSTEM IF NECESSARY FOR THE NEW SPACE CONFIGURATION. C Nil CONTACT LENS 1 MODIFICATIONS SHALL BE DESIGNED AND INSTALLED BY A QUALIFIED FIRE SPRINKLER CONTRACTOR,WHO 0 ROOM � X RECESSED EXTRUDED ALUMINUM EDGE LI f EXI f SIGN WI SHALL PREPARE DESIGN/SHOP DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS TO THE LANDLORD M Q O R RT A�N N CI RED LETTERS FOR CEILING OR WALL MOUNTING RED LED AND BUILDING AND FIRE DEPARTMENTS FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. ALL WORK 13 4 101 I • \ EX/DM , 2 X2 INCLUDED.TO BE RECESSED MOUNTED U.N.O.(FOR NYC SHALL BE DONE IN ACCORDANCE WITH NEPA,STANDARD 101,AND ANY OTHER STATE OR LOCAL CODES - 10.----" ,. • '\. OR CHICAGO CONFIRM WITH MANUF). PROVIDE HAVING JURISDICTION. A R C H I T E C T — CLG. HT.= 10'-0" • \, CURRENT LIMITER WHERE REQUIRED. DESIGN STANDARDS: • c") c") I 711 N. FIELDER RD. C AC-4 • , .- i' - ISI 21-S 2T-S 2 FT LONG,SINGLE CIRCUIT,WHITE TRACK HARD CEILING AND CEILING TILE AT RETAIL AREA/STOREFRONT:WHITE CONCEALED HEADS;RELIABLE ARLINGTON, TX 76012 \A i.' MODEL'G-4';TYCO'RF 11' PH: (817) 635-5696 •OPTICAL STATION I' 0' 1'-0'1�i TL TL -CEILING TILE AT OD,AND LENS PROCESS: RECESSED WHITE PENDANT HEADS WITH WHITE TRIM RINGS; FAX: (817) 635-5699 sSEX/DM GIMBAL STYLE LAMP HOLDER,WHITE RELIABLE MODEL"G Fl;TYCO'TY L' 13 4 102 - S\, -CEILING TILE AT LOUNGE,OFFICE,AND BACK OF HOUSE:WHITE PENDANT HEADS WITH WHITE TRIM RINGS; Seal — 10 CLG. HT.= 10' 0" v " ,[-, 4T-S 4 FT LONG,SINGLE CIRCUIT,WHITE TRACK RELIABLE MODEL'"G";'TY L' t Y�;j� • 1 C AC-4 I� — i \_----\. — K•`\N\��\�-xs.V N.SN"\\��' 1. TL \I cEx) GIMBAL STYLE LAMP-HOLDER,WHITE R,i — — _ _ � '�' 0 4-LCM-A102-REV 0.0 Si) ._ ] N 6T-S CORTLANDr,LI' '.. ' 6 FT LONG, SINGLE CIRCUIT,WHITE TRACK 1 1 `\.' "- TL :'�+ E� �� cam : r_-, i I 1 1`',' i►*��I Q TL GIMBAL STYLE LAMP-HOLDER,WHITE , ` t;a:. `,,.:,, : LINGTO ,T�.'n,� . -- PRETEST v.l -... /' I�; Ewart ........ -- �` /If+� �r 8 FT LONG,SINGLE CIRCUIT,WHITE TRACK v i • �° • ° '\ SUPPLY 12"X24" / 24"X24" 7;1'. ' 1• d`s-: 111 , O 3 10 CLG. HT.= 10' 0" • / TL GIMBAL STYLE LAMP HOLDER,WHITE rL—InI RETURN fir*' RETURN 0\1:� C AC-4 i ! 121.5 12T-S , A 12 FT LONG, SINGLE CIRCUIT,WHITE TRACK Architect/Engineer Job No.: HVAC AIR DEVICES SHOWN FOR REFERENCE AND SPRINKLER HEAD ii �1— {s.\\\\\\\\\\\\\\\\�N\\�\N\\\\\\\\N\\N\\ ti\\�� TE TL COORDINATION.REFER TO MECHANICAL PLANS FOR MORE (EX) =EXISTING GIMBAL STYLE LAMP HOLDER,WHITE INFO. (N) = NEW IIII Nextore Store Design Revision No.: • U -� bill - x/AM EX/AM 3 LCM AI02 REV 0.2 5 LCM A102 REV 0.0 C AC-4 - ' - REV 0.0 --- — • � ��;. '�I 'j� •.�i ei: 8,�•:iw c:` <" -L'Eola �c�:�: %\\ ray \` :,E\ " EXAM ��. �: `a> ,. D// �;� � �� .s�. '�, ��� \ ;'\ I 1\ \\\\ {.r .,;i;;ZJ , :fi Thr\ . ROOM a ` ffi : �r E aT Nextore project fes,, `\'� ��. t ,�/` I ' 4 0 r' '` ,. : : �, ,�: , , & �:, � ,,. _ Number 74(}95 -- CLG. HT.= 10'-0" AD \ SYMBOL TYPE MANUFACTURERrQTY ; \ PART-NUMBER INPUT WATTS LAMP LAMP TYPE DESCRIPTION MOUNTING CEILING TYPE _ v \ LensCrafters Design Type: 6 - I 1 - � , — GLOBAL 6 EX/AM EXISTING V.I.F. EXISTING V.I.F. V.I.F. N/A V.I.F. EXISTING RECESSED 2 X 2 WITH LED PANEL RECESSED ACOUSTICAL o I\ EX/ ISSUED FOR: rt___ I�- . QClient Review ❑LL Approval � — \ _Ct\\\ \\\\\\\\t' DDOB Permit ❑Bid -_- EX,TM EX/TM INDY Q150T 10 110WATT LED LAMP LIGHTING TRACK WITH TRACK HEAD LED LAMP SURFACE ACOUSTICAL CI DOB Permit- Re Submit 0 Construction II AM EX/AM Title [x/ • v OLxi)r' EX/DM EXISTING V.I.F. EXISTING V.I.F. V.I.F. 1 17 WATT LED EXISTING RECESSED DOWN LIGHTING RECESSED ACOUSTICAL/ GYP.BD. REFLECTED CEILING • x 1 I' Ex/XM EX/XM EXISTING V.I.F. EXISTING VIE. V.I.F. 1 V.I.F, EXISTING EXIT LIGHT FIXTURE SURFACE ACOUSTICAL/ PLAN W/90 MIN BATTERY GYP.BD. -- 1 { I Date Sheet PLAN NORTH 12-2-16 Drawn By 1 REFLECTED CEILING PLAN6-LCM-A102-REVo.o Check S�TBAFF A102 SCALE. 1/4'=1'-0' (1) ey CM ....._.. NE/Z-TORE / I - i�%f c�.\ ,' \ �. uF--� i:F - fi#. :..•.. ,b e%iJ/. �l%, ���PH ,.�.Z, ter �y •4000 Luxottica Place,Masan,OH 45049 •*1(513)765-6000 / \ L U FINISH-- N I S H SYMBOL K EY.�I. -''� .. ew ' 4., I •6 Creamery Broak,East Granby,C706026 •,11516)3932484 : � GENERAL COTES FINISH PLAN j m FLOOR 1. LINE Or PARTITION ABOVE(SI'OWN DASI ILD. A. G.C.IS RESPONSIBLE FOR ANY PREPARATION OF THE FLOOR SLAB AND PROCUREMENT OF MATERIALS STO RE #87 5 3 a� REQUIRED TO PRODUCE A FLUSH CONDITION BETWEEN THE STORE LEASE LINE AND THE EXISTING p Ln ® 2. NO TRANSITION STRIP AT PORCLLAIN TILL.TILE TO BUTT UP TO MILLWORK. MALL FLOORING. Was a S h i n ton Square L) am = BASE COORDINATE STOPPING POINT OF PORCELAIN TILE Will I TENANT'S gg 1v9ELLWORKER. B. G.C.IS RESPONSIBLE FOR INSTALLING ALL FINISH FLOORING.G.C.IS ALSO RESPONSIBLE FOR ALL FINISH 9300 SW Wa lington Square Rd. \/ am =WALL 3. G.C.TO PATCH AND REPAIR EXISTING CONCRETE AS REQUIRED PER NEXTORE MATERIALS BEHIND AND UNDER ALL MILLWORK. I j ULL TILE> ©ED =TRIM PROJECT MANAGER'S APPROVAL. PREPARE CONCRETE AS REQUIRED FOR C. REFER TO ARCHITECTURAL SPECIFICATIONS/FINISHES SCHEDULE THIS SHEET&REFER TO GENERAL Tigard, OR 97223 NEW FLOOR FINISH.ENTIRE LEASED SPACE. NOTES ON SHEET G100 $, -CEILING(SEE RCP FOR ♦ 4. MACY'S FLOOR TILE TO REMAIN. D. ALL TENANT FURNISHED ITEMS(MATERIAL AND LABOR)TO BE SCHEDULED,COORDINATED AND LOCATION) SUPERVISED BY G.C. Construction for: 5. GC TO WRAP BASE AND WALLCOVERING AROUND WALL CORNER& INTO 4" J ,�, A__ ,_ 1-LCMOO-A103-REV00 QUIRK.PAINT REVEAL P117. E. REFER TO DOOR SCHEDULE FOR DOOR FINISHES.CO TO PREP EXISTING DOORS PRIOR TO 1\ {2C FINIS'INC. . i rimy 6. REFER TO INTERIOR ELEVATIONS TOR EXTLNT OF WALLCOVLRINC. I , P101 7. WALL BASE SUPPLIED AND INSTALLED BY G.C.SEE DETAIL 3, SHEET A500. FW IOR CCOMPOLIANCELWITHONAoI STAND RD FOR THF NEW FLOOR,GC OVERIFY EXISTING IN SET TILE AND THE OLAOR TESTOEDIITIONS MEETS AND OF TELE COUNCILEiKWINTERIOR �ATERIALs " 8. G.C.TO INSTALL CORNER GUARD,CG 104, REFER TO THIS SHEET FOR OF AMERICA.IF THERE ARE ISSUES OR DEFICIENCIES,CONTACT NEXTORE PROJECT MANAGER PRIOR TO � . ,.�.IE, e SPECIFICATION. ��� ;��'� ` � ��� ' ... INSTALLATION. Clin • • v ` MATERIAL FLAME SPREAD SMOKE DENSITY 9. {XISTING MIRRORED COLUMNS WITi 14"BASE TO RECEIVE WB102. O v 10. WIDTH OF T102 MAY VARY DUE TO TRANSITION TO B.O.H..MAINTAIN a"' 0_'Sr_ I PLASTIC LAMINATE 80(BONDED) 95(BONDED) EACH SIDE OF GYP.AT OPENING. D O u'1 CARPET 26-75 450 OR LESS 11. START TILE LAYOUT W HALF CARPET TILE AT TRANSITION.TRANSITION TO L * r eD '•' I '\" - - OCCUR UNDER DOOR SIDE @ DOOR STOP. C� �/ J ." VINYL TILE 0.45 450 OR LESS O 12. NOTE DIRECTION OF CARPET TILE Li 0 1.2 - LAY IN CEILING 25 10 FRP 150 245 OxO . . • \,„ \ VINYL BASE 0.45 450 OR LESS . 0< 3 ,T, 4 LCM17 A103 REV04 2 LCM17 A103 REV00 3 LCM17 A103 REV44 �' 0 r•-• a� v 1 ii ?p :! gI \ : cl Vit::.: .,. :: ::: ::: ::: ::: : ::: :' ��'`�: t\. �'� � ,a! ����� 4.. � ; ' k ITEMk. DESCRIPTIONMFG. PHONE # MODEL # COLOR `u • ., � 'IAR / / REMARKS (f� o z v. ARCHITECTURAL SPECIFICATIONS / FINISHES NOTE:ALL SPECS MAY NOT BEUSED INEVERY STORE v v �, GENERAL NOTE:FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS 9 3 0 INTERIOR ACRYLIC LATEX l/) +J SHERWIN WILLIAMS (800)474-3794 l PAINT P101 PAINT(EGGSHELL)(EXTRA WHITE) INTERIOR WALLS AND SOFFITS LJ EXTRA WHITE,SW7006 O r! . - PAINT P104 PAINT(SEMI GLOSS)(EXTRA WHITE) SHERWIN WILLIAMS (800)474 3794 EXTRA WHITEINTERIOR R SW7006 EX DOOR FRAMES EVERYWHERE 1 < V I PAINT P114 1. PAINT(EGG SHELL) SHERWIN WILLIAMS (800)474-3794 SW7066,GRAY MATTERS ACCENT WALL PAINT-OD AREA k, - ' - PAINT P117 PAINT(SATIN) SHERWIN WILLIAMS (800)474-3794 SW7068 GRIZZLE GRAY MDF FILLERS AT EYE EXAM SIGN C` N. WC105 WALLCOVERING WOLF GORDON INC. HEIDI REEF RFF 2557 VINYL WALLCOVERING WITH 800 347 0550 X864; MOBILE 330 6181296 ® WALLCOVERING SCHWARZINGER OSNABURG BACKING -COLOR:ANCHOR HEIDI.SCHWARZINGER@WOLFGORDONCOM WALLCOVERING WC146 WALLCOVERING SOURCE ONE MIKE THOMPSON, TEXTURA STONE,COLOR:BLACK LOCATION:REFERENCE ARCHITECTURE DRAWINGS FOR LOCATIONS&SEAMING. �t CONTRACT 614-551-7928 DIMENSIONS:12"X24", 1.5 MM.THK. NOTES:PRODUCT IS GLUED TO WALL WITH STANDARD POLYURETHANE ADHESIVE �` T I � P10_BEHIND 1 --c-C' INSTALL TILES HORIZONTALLY. �W PT105 ) PERIMETER ttttI Q BASE WB101 WOOD WALL BASE 6H x 3/4"T PAINTED WOOD BASE FINISH P104 \ -// WALL FIXTURES W/3/8"TOP CHAMFER Revisions: BASE WB102 WOOD WALL BASE 4"H x 3/4"T PAINTED WOOD BASE FINISH P104 Mark Date By W/3/8"TOP CHAMFER Q 12-2-16 STAFF ROD SEABOLT MODEL/COLOR: 90%REVIEW SET JOHNSONITE CDC DISTRIBUTORS FOR USE ON ROUND COLUMNS ONLY �_ I_ BASE DWB101 MILLWORK WALL BASE (513)560 1040 MANDALAY,MW-50-H6,50 WHITE RSEABOLT@CDCDIST.COM /+s W P101 ROD SEABOLT / \ RETAIL SALES AREA CHAIR RAIL CR100 CHAIR RAIL JOHNSONITE CDC DISTRIBUTORS CHR 50 C OD WAITING,EXAM&PRETEST(PER ELEVATIONS) ©Q B WB101 100 - RSEABOLT@ DCDIST.COM CLG. HT.- 12'-0" I �- CORNER GUARD CG100 VINYL CORNER GUARD S0 WHITE A �\� JOHNSONITE TANDUS VBG-50-A-48 USE ON EXPOSED OUTSIDE CORNERS IN O.D.&B.O.H. SEE SHEET A200/201 FOR — ELEVATIONS&FINISH EXTENTS a k.4 PORCELAIN TILE PT105 PORCELAIN TILE(7 7/8"x 19 5/8"x 1/4"THK) DESIGNER ROUT: WHITE STOREFRONT PORTAL FRAME, INSIDE WD201.VERIFY W G I I. ._ TILE &STONE GROUT;1/16"THK.,MAPEI#38 AVALANCHE ELEVATION \ :: T5--0 PM100 PAINT(SATIN) V.LF V.I.F. MACY5 WALL PAINT TO MATCH EXISTING 9/A�bO d •" k., 1 — - BASE WBM100 WALL BASE V.I.F. V.I.F. MACYS WALL BASE TO MATCH EXISTING LARGE FORMAT PORCELAIN TILE TRANSCERAMICA NOREEN SCHERTLER ROADS; ITEM AP66201-SQUARE GREY CALM,(MATTE FINISH) MANDATORY INSTALLATION PER MANUFACTURER'S S I •s„kPORCELAIN TILE PT108 24"X24"xlOmm 11.59 W BRYN MAWR 312 342-4689 GROUT:1/16'THK.,MAPEI#27 SILVER(NO SUBSTITUTIONS) SPECIFICATIONS. Vr TASCA[L 60143 ( ) • Z LARGE FORMAT PORCELAIN TILE TRANSCERAMICA NOREEN SCHERTLER NEW GROUND;ANTHRACITE GROUND,(HONED FINISH) MANDATORY INSTALLATION PER MANUFACTURER'S iz PORCELAIN TILE PT109 A)24'x24`x1Dmm�IPfP2960 159 W BRYN MAWR GROUT:1/16"THK.,MAPEI CHARCOAL(NO SUBSTITUTIONS Architect/ Engineer of Record n [] B.)24'x6'xl0mmpFP2965 TASCA[L 60143 (312)342 4689 SPECIFICATIONS. 0- Q JEFF TAYLOR(P): STACKED MODULAR, MONOLITHIC INSTALLATION,INSTALL MUST INCLUDE MEG. — — — _ 1 CARPET TILE C63 CARPET TILE 24"x24", ULTRA NYLON 6,6 !&J INVISEON (800)241 4586 1404 STIMULATE 24x24 TILE RECOMMENDED INSTALL METHOD, FLOOR PREP&ADHESIVE y.• 1WT172 Li --- -- - C 1M I ` 4 _ r le r - — — - U (800)442-4212; 1774 DUNE TEGULAR,2'x2°x5/8"ANGLED TEGULAR PRELUDE CORTLAND - CEILINGS AC 4 2'x 2'LAY-IN; 15/16"GRID ARMSTRONG OPTION#1 15116"EXPOSED TEE GRID SYSTEM CLASS"A", REFERENCE "LUXOTTICA"AS ACCOUNT NAME `������������-���w��������ti� __ - �a�\�����\, J MORGAN `._ u ARCH ITEC T CONTACT LENS410 • \, STOREFRONT GLAZING CHANNELS,12'LENGTHS. F ALUMINUM A-1 ALUMINUM TIGER (800)898-4437 TIGER DRYLAC 49/80180 WB102 ROOM ■ \I — STOREFRONT BASE,&2"REVEAL PROFILE. ARLINGTON,711N. FIELDER RD. 00 \ FROSTY WHITE#1573 60 MATTE W/SOLID TX PLASTIC LAMINATE PL100 PLASTIC LAMINATE WILSONART (800)433-3222 MILLWORK COLOR CORE @ EXPOSED EDGES PH: (81 7) 635--5696 CLG. HT.= 10'-0" 6012 :I MICHAEL HERTENSTINER DECOMETAL COLLECTION W P101 __. PLASTIC LAMINATE PL102 PLASTIC LAMINATE FORMICA MILLWORK FAX: (817) 635-5699 V') (440)668-7030 2022 BRUSHED ALUMINUM • 11'-0"I '' 1'-D^ LJJ MICHAEL HERTENSTINER COLORCORE2 COLLECTION ' PLASTIC LAMINATE PL103 PLASTIC LAMINATE FORMICA (440)668-7030 7223C-58 NEW WHITE(MATTE) MILLWORK Seal F C63 / 12 C.n , DOORS(ALL SIDES INCLUDING BOTH FACES, LATCH SIDE,416 ''" OPTICAL STATION \° 1--r PLASTIC LAMINATE PL105 PLASTIC LAMINATE WILSONART (800)433-3222 7964K-12 SKYLINE WALNUT ; z 0 HINGE SIDE,&TOP) Y °` ,/ �� B WB102 102 S r--r MP30136R11950 POWDERCOAT SOA V1.0 CLG. HT.= 10'-0" v ' — \I LL MILLWORK FINISH PC100 MILLWORK POWDERCOAT MATTHEWS PAINT BRUSHED ALUMINUM MILLWORK c!,5 GG�+I �y ,,C''', W P101 ARCHITECTURAL NADINE KING RECTANGULAR TRIM#110672 W/BASE ' �` M102 METAL STYLMARK TRIM DETAIL FOR WALLCOVERING,2-PART ASSEMBLY • �, -2 METAL TRIM (763)574-7474 #412007 FINISH-124 _ ,} rf MELAMINE MEL100 MELAMINE PANOLAM (800)672-6652 5557 INTERNATIONAL WHITE/CRYSTAL MILLWORK ARLINGTON,�'� F' ` o�' I I TEXTURE • 0 - -1 ' —. ROD SEABOLT i 0 \_ _ CDC DISTRIBUTORS FLAME SPREAD:ASTMS-84 75 OR LESS,CLASS B SMOKE i .I \ TRANSITION STRIP TS-1 TRANSITION STRIP(CARPET TO TILE) JOHNSONITE PART#CCA XX/#32 PEBBLE DEVELOP:NA, FUEL CONTRIBUTED:NA W P_Dl (513)560-1040 F C63 ::a'x RSEABOLTC.CDCDIST.COM PRETEST ,. © i W P114 ROD SEABOLT B WB102 103 • • 12 B W�lbl CDC DISTRIBUTORS FLAME SPREAD:ASTMS 84 75 OR LESS,CLASS B.SMOKE Architect/Engineer Job No.: , TRANSITION STRIP TS 2 TRANSITION STRIP(CARPET TO CONCRETE) JOHNSONITE PART#EG XX K/#32 PEBBLE (513)560-1040 DEVELOP:NA, FUEL CONTRIBUTED:NA W P101 CLG. HT.= 10' 0" la 1'-0" 1' 0" RSEABOLT®CLx D1sT.CO61 �1 TRANSITION STRIP(CARPET TO VINYL AND SCHLUTER SCHIENL,MINIMAL HEIGHT AS APPROPRIATE FOR FLOORING Nextore Store Design Revision No.: \ Fc TRANSITION STRIP S 1-800-472-4588 TRANSITION ALUMINUM(-A);1/4'THICK EDGE. ZINC STRIP AT OD AREA. I g ' I -11 \ CARPET TO PORCELAIN) WWW.SCHLUTER.COM �� Z ROD SEABOLT VI • '� _ _ CDC DISTRIBUTORS • \ -- I\\\\ \ N... '',.\\ ���\\.Ty�������\\\����\\\�\ Q TRANSITION STRIP TS-9 TRANSITION STRIP(PORCELAIN TO VINYL) JOHNSONITE PART#CTA XX K/#32 PEBBLE BETWEEN PORCELAIN TILE&VINYL — \, -` � (513)560-1040 • • I ��' 111 \ l./") RSEABOLT@CDCDIST--COM Z TRANSITION STRIP(PORCELAIN TO MALL TILE SCHLUTER SCHLUTER-DECO,ALUMINUM(-A)HEIGHT AS APPROPRIATE Nextore project Q TRANSITION STRIP T5 10 1-800-472-4588 FOR FLOORING TRANSITION, 1J4"THICK AWMINUM EDGE BETWEEN RETAIL TILE AND EXISTING AISLE FLOORING) WWW.SCHLUTER.COM Number 74095 EXAM 1-- Roo SEABOLT F C63 Iwir \ CDC DISTRIBUTORS FLAME SPREAD:ASTMS-84 75 OR LESS,CLASS B SMOKE LensCrafters Design Type: ROOM TRANSITION STRIP TS-12 , TRANSITION STRIP(VINYL TO CONCRETE) JOHNSONITE PART#RRS-XXC/#32 PEBBLE 0 \ (513)560-1040 DEVELOP:NA, FUEL CONTRIBUTED:NA 0 B WB102 104 \ RSEABOLT@LDCDFST.COM GLOBAL I W P101 CLG. HT.= 10'-0" ia' o° 1=D"1� ISSUED FOR: 1 ,dmimimimmlik:_fl P114imii °Client Review 0 LL Approval 6 cc PRIMER/SEALER LATEX PRIMER/SEALER FOR DRYWALL ICI DULUX PAINTS (502)969-0181 #1020-1200PVA ONE(1)COAT REQUIRED ❑DOB Permit ❑Bid Cl DOB Permit-Re-Submit 0 Construction 4 PRIMER/SEALER LATEX PRIMER/SEALER FOR METAL ICI DULUX PAINTS (502)969-0181 DEVGUARD#4120 ONE(1)COAT REQUIRED \'\\\\\\\\s'‘\ \\N\�`'..I Lrl Title I.. PRIMER/SEALER LATEX PRIMER/SEALER FOR WOOD ICI DULUX PAINTS (502)969-0181 WOOD UNDERCOATER ONE(1)COAT REQUIRED • TS-10 FINISH PLAN . 1O/A504 CASING T101 HARDWOOD CASING PAINTED 3/4"x 3/4" HARDWOOD SQUARE FINISH P104(TYP.WHERE PT105 MEETS MILLWORK) • y I I 1 CASING 1102 HARDWOOD CASING-PAINTED 6 3/8"W x 3/4"T PAINTED HARDWOOD CASING FINISH P104(TYP.AT O.D. ENTRY) Date Sheet 5-LCM17-A103-REVD0 12-2-16 Drawn By Ci ) FINISH PLAN STAFF A103 E SCAL : 1/4'=r c° Checked By CM ( W PT105 ) / - —G.C.TO PROVIDE AND INSTALL 1X6 FIRE-RATED WOOD \ » BLOCKING IN WALL BEHIND GYP. BD. BETWEEN EACH STUD FOR ILLUMINATED '_ENSCRAFTERS SIGN BY SIGN (w PM10o) WALL FIXTURE MOUNTING.(TYPICAL WHERE WALL FIXTURES 11 CONTRACTOR. ELECTRICAL CONTACTOR NEXTORE . (1. T101 ) ARE SHOWN) A500 TO PROVIDE POWER SEE ELECTRICAL ( T 7101/ DRAWINGS \ a_ r r '- L 3 � 1 1 -,i5-1,:'30 EX. CEILING HEIGHT t )1 EX. C ILING NEIGH T i.. - - -�-�- ' ' STORE48753 - 1 .fEf��(�I�r���E�� — FUL�TILE @ f+uoo — I - Iw T I \ _, I Y9:1_LA_ I _L f TOP ROW Washington Square � - " r9300 SW Washington Square Rd. vvw•w• ••w•vvwv it plywyi.w w•••wwvvGwl vviP'vvvv4441.11•••ri ♦••E•4;0••*••l wvvwvw w w v•ww wwww • -.-r;. 107•-•-•-•-•-•-•-•-•• ''c- Tigard, OR 97223 LD — Z I I RECESSED WALL STANDARDS TO _ m Construction for: MATCH EXISTING MACY'S TYPE. LnI o FIELD VERIFY, LENGTH, TYPE l Kw P101 ) 1 i O cr, o ETC, - I I 1 I II-- Lj L 11V c oas-an 1 , r r iI I c I• o : on ,. . r 40 I I 60 1�• C) ^ \ '" - I 0400 00 0400-00 0400 00 0400-00 N,08 i0 00 ` 0020 0_ 0400-00 040000 0400-00 0440-00 \ ' D C D B WB101 0440 00 0430 00 0430-00 0430-00 0430 00 0440blf 0440-00 043000 0430-00 0430-00 / Limi Q / L , X B WB101 %._ 71- CO ( B WBM100) 1' 45.. 42'-01.. 4 5 l� O `\ LE g 4 A 118," Azao U O RETAIL SALES AREA: 100 LL x Q �1 1 - RETAIL SALES AREA: 100 0 SCALE: 1/4"-1'-0" SCALE:1/4"=1'-0" 2 0 ,— V / W PT105 ) / 4- 03 `` OCL cu GC TO PROVIDE AND INSTALL CABINET HANDLE BUMPERS U 4 P101 AT ALL LOCATIONS WHERE HANDLES CAN MEET WALL IN 3 E 1 // \ OPEN POSITION.SEE DETAIL 4 ON SHEET A500. +� A500 ( T T101 ) �O EX. CEILING HEIGHT \\ / EX. CEILING HEIGHT i ` ) x $\ :::..::.::c.:: :::I �� �\ — KW P101 f KW P101 (w P101 , Z D 3 2 1 � y FULL TILE @t i TOP ROW \B.O. CEILING B.O. CEILING B.O. CEILING < 4, 1-- 1 N 1. 10'-0'" A.F.F. 10'-0" A.F.F. 10'-0" A.F.F. LJJ >-, 4 I I —v2_. GC TO PROVIDE v EVE L ,GAJ \ AND INSTALL MDF FILLERS RECESSED FOLLOWING ELECTRICAL \ \ 1 \ __ z INSTALLATION PANEL PAINT I, u o o OF SIGN.SEE / P101 • p 60 . C) DETAIL 6/A400, / o �bN v- I m o Q o OPEN TQ L V = LL,V BIW Q --.. .. T102 o w o o BEYOND ii o II B1 H \ r, \ o a °. CASED OPENING0 OPEN (/ g I I I iGS CL02 R Revisions; o \ i Sr L03 ' GS BOHO1I OPEN I - E Mark Date By A500 --J M — o r`� /� 12-2-16 STAFF \ 0400-00 0440-00 \ \ — \ \ , ,, f I 90%REEWSET 1" bQ.00 (VII \ \ / \ ^ \ / - \ A 2' 18" R.O.HOLD 5'-9, P101 I (B WB10i) (B WB102) (B WB102 ) ( B WB102 ) (B W6102 ) ( B W6102 ) B W B101) C" RETAIL SALES AREA: 100 C4: RETAIL SALES AREA: 100 , - CONTACT LENS / OPTICAL STATION: 101/102 r-6 OPTICAL STATION; 102 CONTACT LENS / OPTICAL STATION: 101/102 A SCALE: 1/4"=1'-0" SCALE:1/4 =1-0" y SCALE:1/4"=1'-0" f/ SCALE:1/4"-r-0" SCALE: 1/4"-1'-0' A A (1/1/ P101 ) (VI P101 ) ( W P114 KW P101 ) (W P101 ) Architect/ Engineer of Record - i B.O. CEILING ,t B.O. CEILING _ B.O. CEILING - _ - B.O. CEILING B.O. CEILING 10'-0" A.F,F, 10'-0" A.F.F. 10'-0" R.F.F. 10'-0" A.F.F. 10'-0" A.F.F. 8" C IM - / CORTLAND /�� '� '� 9„ M 0 R G A N 1 \ ARCHITECT f o OPEN TO o o ""`A"' LCM G'32 I o \1 I I LI' + s... ,GSPWfj . , o BEYOND b � 4\ �' � LCM- .16 I \ � _� 711 N. FIELDER RD. ARLINGTON, TX 76012 I ` I I LCI-GH30 LC-GH3o PH: (817) 635-5696 J Io b a" o FAX: (817) 635-5699 GS CLD2_R iEn En a 1'—o" 1-_, "Y - - (D00` '1105) Seal ' (F'. E P104) �� T r t 44) SE CL04 ^ \ \ A \ \ �' , 1` I \ > ( ) \ \ > > ( r COR, I LA S "_.:;"-,:i' B WB102 B WB102 B WB102 B WB102 KB WB102 B WB102 B WB102Cr�,f�i INGTQN,TLr„S Le-1 PRETEST ROOM: 102 _ PRETEST ROOM: 102 PRETEST ROOM. 102 _ i -5. $ 9 EST ROOM; 102 10 -+� � CONTACT LENS: 104 PRET SCALE: 1/4'=1'-0” SCALE:1/4"=1'-0' SCALE: 1/4"-1'-0" 11 SCALE:1/4"=r-0" 12 SCALE: l/4'-1'-0" F Q� V6" Architect/Engineer Job No.: 24'x24"xl/4" PLEXI SHIELD.COORDINATE DIMENSION FROM BACK WALL INFIELD. PLEXI TO Nextore Store Design Revision No.: PROTECT WALL FROM SWING OF EQUIPMENT ARM. FASTEN TO STUDS OR TOGGLE BOLT(8)SCREWS. REV/ 0.0 (W P101 ) ADDITIONAL PLEXI PIECE MAY BE REQUIRED DUE (VV )P101 \ G V t.l TO SITE CONDITIONS.GG TO VERIFY WITH DR. (VVP114 ( W P101 ) / EQUIPMENT Nextore project }B.O. CEILING B.O. CEILING _ B.O. CEILING B.O. CEILING - Number 74095 10'-0" A.F.F. 10'-0" A.F.F. 4, 21„ 10'-0" A.F.F. 2' b'"C.L. A.F.F.IN WALL 10'-0" A.F.F. OUTLINE OF LensCrafters Design Type: ELEC. OUTLET RECESSED PROVIDED ANDD INSTALLED BLOCKING C GLOBAL OUTLET BOX. RE: SCREWS FOR PLEXI SHIELD \ -- _ ELEC DRAWINGS GRAINGER — \ 1 j \ WASHER,#8 i % \/ Q o a \ 4 ITEM#2DE99 SINK 'SK 7' ISSUED FOR: o I%ICIient Review ❑LL Approval RE: PLUMBING o ! /\ . 'E? m 0 o MFR.MODEL#908018-PG V.I.F. DRAWINGS o m y 4 0 j �.. ;' L, o COUNTERSUNK WASHER, NICKEL / a ®DOB Permit ❑Bid o — .. ,../— — --' - FINISH, FITS BOLT SIZE#8, \ ODOB Permit Re Submit ❑Construction INSIDE DIA 0.210 IN, `.9 `�' LE TOWEL \ // FlSE-0D03 SE-0D03 O Z SE 0003 -- 4 M �t- O P 104 u' a OUTSIDE DIA 17/32 IN, - O (FRAME P104.4 E-, r+ o -1 r Title I r -_..,,_ -\--` 0o v FOR FINISHED APPEARANCE n� \ �` l — S[ ODLII 'tSl \ • SE-0D02 ~¢ \ SE-0D01 _ 1 FOR USE WITH 82 DEGREE FLAT -- -__ Z o o INTERIOR O \ o I Ly_, AND OVAL HEAD COUNTERSUNK 0 in v 'II N N w SCREWS. N 'v _ ,` O J— I- ELEVATIONS 15 K {B W6102� KB //W6102) ( B WB102 / B WB102) Date Sheet \\ 12-2-16 _ Drawn By REFRACTION ROOM - .) REFRACTION ROOM 15 REFRACTION ROOM l6 REFRACTION ROOM STAFF A�00 14 Checked By SCALE:1/4"=1"-0" SCALE:1/4'=1' 0' �� SCALE:1/4"=P-0" SCALE: 1/4"=t-0" CM • . . , -FoRE NE EXISTING 2ND FLOOR EXISTING 2ND FLOOR 3 8"x 20GA METAL STUD EXISTING 2ND FLOOR 3$"x 20GA METAL STUD EXISTING 2ND FLOOR ` - CONCRETE AND METAL DECK CONCRETE AND METAL DECK DIAGONAL BRACING TO CONCRETE AND METAL DECK DIAGONAL BRACING TO CONCRETE AND METAL DECK OVER STRUCTURAL STEEL OVER STRUCTURAL STEEL STRUCTURE ABOVE OVER STRUCTURAL STEEL STRUCTURE ABOVE OVER STRUCTURAL STEEL alaa0oLMatt;cdP;ace,MaSon,oHasoao • 1(513)765-6000 • • 0 6 Creamery Brock,East Granby,CT 06026 •+1(516)393-2484 • n. n I-1 I I I-1 n B.O. DECK - I f 1- 1 r 1 Il n, f B.O. DECK l -1 I-1 /7 I-1 1- r' B.O. DECK y �, -+ t B.O. DECK STORE #8753 17'-6"A.F.F. — 17'-6"A.F.F. — m 17'-6" A.F.F. \\•\,,,,, \\. 17'-6" A.F.F. Washington Square 19300 SW Washington Square Rd. Q _o .__ _d Tigard, CSR 97223 • I EXISTING BUILDING STEEL . EXISTING BUILDING STEEL nn EXISTING BUILDING STEEL I EXISTNG BUILDING STEEL WHERE IT OCCURS ff WHERE IT OCCURS 4 Cr WHERE IT OCCURS 4 - - �• WHERE IT OCCURS Construction for: 3 5/8" X 20GA METAL STUD • lI • BRACES @ 48" O.C. 3 a"x 20GA METAL STUD • EXTEND EXISTING PARTITONI DIAGONAL BRACING 3 a"x 20GA METAL STUD 3 5/8" X 20GA METAL STUDS _t3a� -, AS REQUIRED FOR NEW • ALTERNATING TO STRUCTURE DIAGONAL BRACING • CEILING TIE IT.3 5/8" METAL •:7ABOVE,48" O.C. (TYPICAL) ALTERNATING TO STRUCTURE TO CONCRETE WALL WITH BRACES @ 48" O.C. SECURE STUDS @ 16" O.C.WITH 5/8"' :,i -- — — — ABOVE,48"O.C. (TYPICAL) � POWDER ACTUATED . TYPE "X" GYP. BD. I T.O. PARTITION 6 _ FASTENERS — • �' •• i A300 CEIL6ING HEIGHT Z A300 I I- I �I �Q CEILING HEIGHT L _ ,jr-rerrr 3 5/8" TRACK(2)#10 SCREWS \ L r f,e,,, ,, ,,,,, CEILING HEIGHT DLn • 12'-0" A.F.F. - 12'-0"A.F.F. — 12'-0"A.F.F. W O TO EACH WALL STUD 3 5/8" X 20GA RUNNER TRACK 3 5/8'" X 20GA RUNNER TRACK cdI 1 • 4- SECURED TO WALL STUDS W/ 0 — SUSPENDED ACOUSTICAL SECURED TO WALL STUDS W/ L5 0 . I #10 SCREWS CEILING #10 SCREWS - SUSPENDED ACOUSTICAL " SUSPENDED ACOUSTICAL u O CEILING EXISTING BRACE TO WALL , CEILING REFER REFLECTED LI- 1 • L1. CEILING HEIGHT CEILING HEIGHT AI T.O. STND CEILING HEIGHT ,� CEILING PLAN FOR CEILING 0 C 0 10` 0"A.F.F. 10'-0"A.F.F. 10'-0"A.F.F. 10' 0"A.F.F. HEIGHTS D ` )• • SUSPENDED ACOUSTICAL �: 4 © 4 CEILING L 0 �` • ' I OD RETAIL AREA ~52 a� RETAIL AREA OD AREA EXTERIOR EXTERIORLim) l'' r NOTES: H t c6•_ • !� GYP. BD.VENEER OVER 8"GYP. BD.VENEER OVER A.)WALLS SHALL BE PLUMB TO WITHIN `- • —1 . NOTES: 3 5/8" METAL STUDS @ 16" -3. p z EXISTING BRICK VENEER - EXISTING WALL. LEVEL "'4" EXISTING BRICK VENEER -r EXISTING WALL. LEVEL"4" 1/8"TOP& BOTTOM AT MILLWORK v-) x FINISH. FINISH. NEW PARTITION WITH RECESSED —,. A.)WALLS SHALL BE PLUMB TO WITHIN O.C.WITH 5/8" TYPE "x" ID q� EXISTING MASONRY WALL — EXISTING MASONRY WALL WALL STANDARD: EQUAL TO 1/8"TOP & BOTTOM AT MILLWORK O° GYP. BD. LOCATIONS ZJ 0 I EXISTING IN WALL RECESSED 0 < EXISTING IN WALL RECESSED CLEMCO ELITE 3 5/8" STUD,#10 0 LOCATIONS 0 B.) SEE ELEVATIONS FOR WALL FINISHES LA C� d STANDARD TO REMAIN. A STANDARD TO REMAIN. SLOTTING,AND#1216 FLANGE, B.) SEE ELEVATIONS FOR WALL FINISHESQ C EXISTING 3 5/8" METAL STUDS 1 EXISTING RECESSED STANDARDS ARE TO BE EXISTING 3 5/8" METAL STUDS EXISTING RECESSED STANDARDS ARE TO BE AND 5/8"TYPE "X"GYP. BD. LLI 41( -'n>, @ 16" O.C.WITH 5/8" TYPE COVERED WITH NEW DRYWALL IN SUCH A @ 16" O.C.WITH 5/8" TYPE • • COVERED WITH NEW DRYWALL IN SUCH A OD RETAIL AREA v MANNER AS TO PRESENT A FLAT AND - • MANNER AS TO PRESENT0A FLAT AND "X"GYP.. BD. "X" GYP. BD. I � SMOOTH SUBSTRATE. NO EVIDENCE OF • SMOOTH SUBSTRATE. NO EVIDENCE OF THESE EXISTING STANDARDS SHALL BE - - THESE EXISTING STANDARDS SHALL BE EXISTING 3 5/8"X 20GA EXISTING 3 5/8"X 20GA 4 ALLOWED TO TELEGRAPH THRU THE NEW -- 4 ALLOWED TO TELEGRAPH THRU THE NEW TRACK (2) #10 SCREWS TO TRACK (2)#10 SCREWS TO n CONSTRUCTION IN SUCH A MANNER AS TO - • CONSTRUCTION IN SUCH A MANNER AS TO EA. METAL STUD SECURED B.O. STND EA. METAL STUD SECURED 2 EXISTING#10 SCREWS TO EA. METAL _ '"" ANDCAUSE ANYTHING LESS THAN FLAT FINISHED SURFACE. SMOOTH (2)I 10 SCREWS TO EA. METAL ANDCAUSE FLAT FINISHED SURFACE.A SMOOTH TO SLAB 0 1` 6"A.F.F. TO SLAB STUD SECURED TO SLAB •4 BASE PER FINISH PLAN STUD SECURED TO SLAB KI BASE PER FINISH PLAN _ _ BASE PER FINISH PLAN r 1—, BASE PER FINISH PLAN .././ • i /SCHEDULE. REFER TO SHEET /SCHEDULE. REFER TO SHEET /SCHEDULE. REFER TO SHEET /SCHEDULE. REFER TO SHEET• Recisions: 0 ./ v aro; Date By A103 A103• A300 I p i A103 A3Do Iilul I A103 12-2-16 STAFF L — _ — J —_, 90 REVIEW SET A 11) WALL SECTION WALL SECTION WALL SECTION WALL SECTION A 23 E 4 SCALE.3/4"=1'-0" TYPICAL INTERIOR PARTITION w WALL STANDARD SCALE-3/4"-=1"-0" TYPICAL INTERIOR PARTITION w WALL STANDARD SCALE.3/4 -1 TYPICAL INTERIOR PARTITION w WALL STANDARD SCALE: 3/4"=1'-0" TYPICAL INTERIOR PARTITION w WALL STANDARD • /\ EXISTING 2ND FLOOR A J MAIN SUPPORTS: / \ 3 a"`x 20GA METAL STUD CONCRETE AND METAL DECK DIAGONAL BRACING TO OVER BAR JOISTS 12 GAGE HANGER WIRES AT 4'-0" O.C. EACH WAY _ STRUCTURE ABOVE OB PERIMETER WIRES: \ . I Architect/ Engineer of Record 1 v 1 n n n n n n n n B.O. DECK 12 GAGE PERIMETER WIRES INSTALLED WITHIN $" OF WALL 3 5/8"X 20 GA DIAGONAL AT EACH MAIN AND CROSS TEE TO WALL JUNCTURE BRACING @ 48"O.C. 3"X3"X3"X18 GA CLIP ANGLES TO • • 17'-6" A.F.F. TOP TRACK AND DIAGONAL ALTERNATING TO THE a O BRACING W/(2)#10 SCREW `�/ LIGHT FIXTURE SUPPORT: STRUCTURE CONNECTIONS, EA. LEG.CLIP ANGLES AT 48"O.C. MAX. C IM _ 12 GAGE WIRES ATTACHED TO MAIN OR CROSS TEES WITHIN 3" �� C 0 R T L A H 0 3.4 FIRE PROOFED STRUCTURE OF FIXTURE AT EACH CORNER. AND 12 GAGE SAFETY WIRES ATTACHED I c C M0 R G A N G.C.TO REPLACE ANY FIRE PROOFING TO FIXTURE (OPPOSITE CORNERS), EXTENDING TO STRUCTURE ABOVE. i 3 5/8" X 20 GA TRACK A R C H I T E C T DAMAGED BY NEW WORK. INSTALL ONE SCREW AT OPPOSITE CORNERS OF FIXTURE TO MAIN OR CROSS TEES. 711 N. FIELDER RD. — ARLINGTON, TX 76012 PH: (817) 635-5696 eyeimK — l I 2.116 -- FAX: (817) 635-5699 — ACOUSTCAL CEILING ACOUSTCAL CEILING Seal . nr 3$"x 20GA METAL STUD ` DIAGONAL BRACING p� (X� s ,� METAL STUDS SECTION DETAIL �:�'� / COM-11N. _ f„ , uAN ALTERNATING TO STRUCTURE �L,) a� ; ABOVE,48"O.C. (TYPICAL) A B I It I ` SAFETY _ ARLINGTON,TEXAS WIRES ( B TRACK TO BRACE DETAIL ,,i - CEILING HEIGHT 119`5 r ''- ii 10,-0" A.F.F. — SCALE: 3"=1'-0" 0E1033-0 3 5/8" X 20GA TRACK �� (2)#10 SCREWS TO EA. METAL O SUSPENDED ACOUSTICAL SCREW I r ' STUD CEILING REFER REFLECTED CEILING PLAN FOR CEILING — CP, 1 — — Q Architect/Engineer Job No.: HEIGHTS Nextore Store Design Revision No.: NOTES: 3 5/8" METAL STUDS @ 16" A.)WALLS SHALL BE PLUMB TO WITHIN O.C.WITH 5/8' TYPE "x" 1/8"'TOP& BOTTOM AT MILLWORK l - RE'I V J. GYP BD LOCATIONS l B.)SEE ELEVATIONS FOR WALL FINISHES 1' Q'y Nextore project 0 Number 74095 OD AREA OD AREA LensCrafters Design Type: SCREW ,, . 3 5/8"X 20GA TRACK CEILING TILE " �i r,. .. (2)#10 SCREWS TO EA. METAL LIGHT FIXTURE — METAL STUDS SECTION DETAIL ISSUED FOR: STUD SECURED TO SLAB (TYP.) t _s, tiM Client Review ElLL Approval 01)013 Permit ❑Bid METAL TRACK PER SECTION DETAIL ❑DOB Permit-Re-Submit ❑Construction — --;1/ BASE PER FINISH PLAN /SCHEDULE. REFER TO SHEE 1 I) d :.' HILTI X-ZF# 32 P8/36M (0.145" SHANK DIA) C I A103 ,. title FASTENERS @ 16" O.C. (OR EQUAL) SECTIONS A300 I \ J I METAL "T" BAR L !•.:7 CONCRETE SLAB Date Sheet 12-2-16 WALL SECTION ( SUSPENDED CEILING DETAIL TRACK TO SLAB DETAIL Drawn By 5 A „_ . C A300 Checked By SCALE: 3/4 =1-0 TYPICAL INTERIOR PARTITION w WALL STANDARD SCALE: 1/2"-r-0"-0SCALE:3"=1'-0" CM • . . • N NEX-RDRE . . . .. . , .. . . •::•.,. . . • .. 4000 ttnnanCa Place.Mason.OH 45040 •+1(513)765-6000 •6 Creamery Brook,€ast Granby,Cr •+1 1516}393-2494 •TOP@2' 10' A.F.F. mico` STORE #8753 f' - Washington Square • • CHAIR RAIL: 6"WALL BASE 9300 SW Washington Square Rd. JOHNSo I • FINISH: P104 Tigard, OR 97223 RAMPA' CHR 0 • (WHI : • JIM N CABINET HANDLE WALL BUMPER Construction for: 61141:11 J4mm PROVIDEDANDINSTALLED BY GC PARTITION PER CONSTRUCTION PLA • SEE SHEET A100 ARCH. FINISH SCHEDULE PROVIDED AND FOR MODEL INFORMATIO . INSTALLED BY G.C. PROVIDE WHERE ANY CABINET DOOR HANDLE CAN MEET WALL SURFACE IN OPEN POSITION. J BOX ABOVE CEILING © 10'-6" A.F.E. FINISH FLOOR, \\ mj ,. BY ELECTRICAL CONTRACTOR WITH FLEXQO CONDUIT WHIP ROUTED IN WALL THRU SEE SHEET A103 Lll CASING . SEE ELECTRICAL DRAWINGS �- \V D C) - p coB.O. O.D. CEILING ' lir 1111 IIIIIIII �'TTLTZ- v l O ›..,.. LT B.O. R.O,/T.O.TRIM = 9' 4 5/8" A.fiACTCLG CHAIR RAIL DETAIL 3 WALL BASE DETAIL 4 CABINET DOOR HANDLE - WALL BUMPER LI- o ,9, 0 SCALE:6"=1' 0'° 2 LCM17 A500 REV00 _) SCALE:6'1=11-0' 3 �LCM17 A500 REVO0 SCALE:6" = 1' 0" 4 LCM17 A500 REV00 ACT CLG � N 0 (:: (WD201) WOOD FINISH. INSTALL WALL COVERING (WC105). PAINT EXPOSED GYP. BRD.- v PROVIDED BY TENANT. CUSTOM FIT PROVIDED AND INSTALLED BY WALL BEHIND MILLWORKS TOp 6" WALL P101 O 2_ JD rim, .< T T102 B �481oi ) CORNERBEAD 03 Ln I } MILLWORKER. v ILLUMINATED "EYE EXAM" SIGN +(75 �-' CABINET BY SIGN CONTRACTOR - - • �� \ PORCELAIN TILE & MORTAR BED CASED OPENING TRIM - - - OVER 5/8"CEMENT BOARD in Ox (BACKSIDE) PAINTED "P104" Ln —�J — —^ - W \ ZQ O C ( T 1102 / < p 411( - l/) SIDE MDF FILLERS BY GC J� lJ - \ / el 5/8" GYP. W FINISH BEHIND d- v ALIGN TO BACKSIDE OF SIGN 6 3/$"W x3/4"T TRIM PAINTED q s MILLWORK L,ico n v W CABINET: B.O. SIGN CABINET P104 GLUED & SCREWED. COUNTER Lr-A00\ '� , ions ;;;„;„��� 4pit..'�*As*" :. '' E 5/8'° GYP.W FINISH BEHIND 1/2"THK X 1' S 1/2"H x 2 1/2'"W 21, 8'-0" ��� \ \ \ - \ elcAL***.R,r+ PAINTED MDF 2 PAINT. PROVIDED AND INSTALLED BY A. - \ ' A MLN. MILLWORK (EQ.THK. FILLER @ EA. SIDE BY GC) G.C. LINE OF MILLWORK EDGE. _ FINISH P117 , SEE ELEVATION SHEETS A200&A201 rrii,1- EE E EVATI N SHEET A2 F R DIMEN 1 N r 0 T101 - B.O. FINISHED CASED Q ( ( �� S L O 00 O S O S Cy ( ( Q FINISHED OPENING BETWEEN T Co AND EXTENTS OF MILLWORK i.o FILLERS SHALL BE 3'-11" HOLD. s or 3'° SIGN CAB.THK. OPENING: NON-COMBUS ABLE 9'-3 7/8"WHEN DOORW ' � \ � 3/4"x3/4" SQUARE TRIM - PAINTED BLOCKING P104 -GLUE & SCREW. COUNTER SINK / ABUTTS TILED WALL, > SEE ELEVATION SHEET A200 SCREWS, FILL AND PREPARE FOR PAINT, Revisions: 9'-2 7/8"WHEN NOT fl 11 LLINE OF SIGN FOR DIMENSIONS AND w 1102 1 ( EXTENTS OF WALL COVERING PROVIDED AND INSTALLED BY Mark Date ABUTTING TILED WALL. • v ABOVE \ /�^� �� /,�^\` �. 3-- - MILLWORKER. SEE ELEV 1/A200 � By SEE CONSTRUCTION PLAN y� - - - 4" 4 A 12-2-16 STAFF A101 DOOR TYPES FOR 'r / // 1" SPECIFIC HEIGHT e MILLWORK ill LINE OF MILLWORK EDGE. 9o%REvrEtivSET t . — — — _N— — — — SURROUND ABOVE SEE ELEVATION SHEET A200 SEE ELEVATION SHEET A300 4" MILLWORK PROVIDED BY TENANT. — FOR DIMENSIONS FOR DIMENSIONS AND EXTENTS A 1 (6 wB101) / CUSTOM FIT PROVIDED AND AND EXTENTS OF TILE OF MILLWORK INSTALLED BY MILLWORKER. 1 SECTION THRU - EYE EXAM SIGN CASED OPENING - DETAIL o WALL COVERING INSTALL PORCELAIN WALL TILE INSTALL A SCALE:11/2" = 1'-0" I SCALE:6"= -0" 5-LCM17-A500-REVOO, SCALE:3"= 1'-0" 6-LCM17-A500-REV00 SCALE:3' = -0" 7-LCM17-A500-REVOO 1-LCM17-A500-REV00 ' 1' �I 1' A A TRANSITION STRIP (TS-14) PER TRANSITION STRIP (TS-4) PER TS-10 TRANSITION Architect/ Engineer of Record PLANS AND SCHEDULES INSTALL PLANS AND SCHEDULES INSTALL STRIP PER PLANS AND/ - CARPET ON EXIST. TLIGN CARPET ON SUBFLOOR TO SCHEDULES CARPET EDGE ACENT ALIGN CARPET PILE HEIGHT WITH /' FINISHED C " ;ODA., •RING ADJACENT FINISHED TILEC [IV _ / FLppRING ALIGN - o ml MILLWORK PROVIDED BY TENANT, LOW'': P?• ARPET PORC.TILE ON THIN SET MORTAR BED CORTLAND i T_ CUSTOM FIT PROVIDED AND INSTALLED v BY MILLWORKER. 1 M 0 R G A N dd00QA“�- • t. - - -. f .. A R C H I T E C T pDOp0�0040a0 "-----;,--.Tz' ���, ,� - - - grim I� 4 ' ITHIN SFT MORTAR BED ; :... 4 ... i i i i i 1 i r 1 r r rJ 1 1 1 r B.O. ACT CEILING UE DOWN CARPET PER GLUE DOWN CARPET PER 4 n n • a ARLINGTON,ETX�R76012 n 121-0" MN%PL NS AND SCHEDULES PLANS AND SCHEDULES • SLAB ABOF EXISTING COICRE 711 N. PH: (817) 635-5696 ACT CLG v \\\\ hS 1/2" F,R, PLYWOOD SUBFLOOR VERIFY FAX: (817) 635-5699 A i NOTE: PREPARE EXISTING PARTITION PER CONSTRUCTION PLAN _>. ""Z� " HEIGHT REQ'D IN FIELD CONCRETE SLAB AS REQUIRED Seal I LINE OF EXTG.CONCRETE SLAB I L[NE OF EXTG.CONCRETE SLAB TO PROVIDE LEVEL yy~ y (1/V \ TRANSITION. C e { PT1O5 I � r PORCELAIN TILE & MORTAR C 1 BED OVER GYP. BD. /" 9 ARLINGTON,ON,TEXAS f;a FLOOR TRANSITION DETAIL FLOOR TRANSITION DETAIL FLOOR TRANSITION DETAIL ,- J-BOX ABOVE CEILING @ 10'-6" A.F.F. :=• cli LENS CRAFTERS" Q 8 - • t 1) ILLUMINATED " w SCALE:6" - 1'-0' TS 14 CARPET TO CARPET 13 LCM17 A500 REV00 SCALE:6' - 1'-0' TS-4 CARPET TO PORCELAIN 9 LCM17 A500 REV00 1�y SCALE:6" - 1'-0" 10-LCM17-A500 REV00 BY ELECTRICAL CONTRACTOR WITH FLEX SIGN CABINET BY SIGN W I Ly � WHIP ROUTED IN WALL INTO SIGN I CONTRACTOR LU CABINET. SEE ELECTRICAL DRAWINGS L w - - - _._ - - - - / \ Architect/Engineer Job No.: rrTIIIii I I I I I I I I I { T T101 ) 11 \ / 4" X 4" SQUARE TRIM PROVIDED Nextore Store Design Revision No.: AND INSTALLED BY GC • REV 0.0 ACT CLG PAINTED "P104" T.O. TRIM 9'-4 5/8" Nextore project Number 74095 LensCrafters Design Type: C.L. @ 8'-11" A.F.F. GLOBAL G.C.TO PROVIDE AND - ISSUED FOR: INSTALL 1 X 6 FIRE RETARDANT BLOCKING ► Client Review ElLL Approval ❑DOB Permit 0 Bid ❑DOB Permit-Re-Submit 0 Construction OUTLINE OF MILLWORK FIXTURE BELOW. Titre DETAILS Date Sheet 12-2-16 • Drawn By I " SECTION THRU - LENS CRAFTERS SIGN - STAFF A500 • SCALE: 11/2" = 1'-0" 11 LCM17 A500 REV00 Checked By • CM 1 g KEY NOTES - MECHANICAL/PLUMBING/ELECTRICAL OVERALL PLAN NBCTORE •4000 Luxottica PVace,Masan,OH 45040 10.1(513)765-60X0 1. LOCATION OF SANITARY AND VENT. FIELD VERIFY LOCATION OF PIPING AND CONNECT TO NEW EC MACY`S. CONTRACTOR IS TO SUGGEST •6CreameyBrook Las Gan 5cC 05026 go+1(516)393-7484 ALTERNATE LOCATIONS IF THEY ARE DISCOVERED DURING BIDDING/CONSTRUCTION. 2. UTILIZE PANEL "R2" FOR THE 60A FEED TO NEW LOAD CENTER 'A" IN THE LENSCRAFTER'S SPACE. VERIFY CURRENT LOAD ON PANEL AND STORE #8753 REPORT TO ENGINEER TO CONFIRM PANEL CAPACITY. SEE RISER DIAGRAM FOR PANEL IDENTIFICATION. Washington 3. LOCATION OF EXISTING P.O.S.ROOM. �f Square SALES Q T. SALES SUPT. BLDG. REQ. BLDG. REQ. 4. EXISTING WATER SUPPLY LOCATION. VERIFY IN FIELD PRIOR TO START OF WORK. 9300 S YYa ington Square Rd. UNUSED / VOID SPACE AISLE CIRCULATION TELEPHONE / ELECTRICAL CLOSET TELEPHONE / ELECTRICAL CLOSET Tigard, OR 97223 85.0 245.2 151,9 62.3 ` 1-LCM-MPE100-REV 0.0 BLDG, REQ. ENTRANCE #6 SALES SUPT. BLDG. REQ, BLDG. REQ. F.R. SALES SUPT. BLDG. REQ. ENTRANCE / VESTIBULE 2% FIXTURE STORAGE PASSENGER ELEVATOR EXTERIOR WALL READY TO WEAR UNUSED / VOID SPACE STAIRS Construction for 150.8 I I 245.3 83.4 1804,0 655 50.3 146.5 BLDG. REQ. A .A . A. i _� _..:- i �■���tr».rrr���a�al��■�wwwrr.�c� _......___- t - LJ �� -- ,,„ EffhhhiF � 309.5TELEPHONE / ELECTRICAL CLOSET ' II- _ + . � 11 ...: ®A \.. ..�LES SUPT. Illl • 1 i / I hiir I ' R57DY TO WEAR �����• -��� I RECEIVING MARKING ` FS / SALES SUPT, Irr a' '� HALL FS 1553.7 MN • ■ ■ �--� �" 22,2 ' NTIMATE APPAREL INTIMATE APPARE j UNUSED / VOID SPACE mamma- �,�r_ .r■ CA _� j 1010.6 839.1 26.2 11 SALES SUPT. STOCK FS FS Ilir ELEVATOR•LOBBY GENERAL STORAGE WOMEN'S SHOES q MSTYLE MSTYLE Ln _1..1 15.0 _ 530.6 3561.5 725.90 LLI 0 F.R. ❑ E �■ _rpm, ❑ ❑ p _ l�,r, -� Q INTIMATE APPAREL •" FS LES SUPT. FS lit ' IBLDG REQ. #dL INTIMATE APPAREL OFFICE - DM � 19�IHT ELEVATOR /535.2 ,, CID 594,0 _ 94.8 INTIMATE APPARELt) 0 >,.. 928.4 SALES SUPT, SALES SUPT. _ �'I `.,A _ FS \ UNUSED / VOID SPACE '" .� ELEVATOR LOBBY , MSTYLE O 0175.0 217.7 1 688.9 1 X OION I Ii'l I ., I I _ [ I I _ I _ j 1 -4 - I = S j i J { ❑ 1348, . . .i1_ __ I C$ ® ■ ..:w LI 0 ,.... ,... INTIMA E APPAREL 1 FS �+- c13 FS ES MSTYLE I 0 a SALES SUPT. T T a_ N c UNUSED / VOID SP E WOMEN'S SHOES j WOMEN'S SHOES FS 2444,7 FS i 88.7 777.1 874.3 -FS ' IMPULSE BEAUTY MSTYLE U '-. .. CO r- V E 1545.9® ® m 1369.3 Cti- D I FS F R FINISH LINE FS FS I z HOSIERY INTIMATE APPAR L919.8 WOMEN'S SHOES WOMEN'S SHOES 1 ( Ox 1125.9 286.7 1111 '� i WOMENS 1572.4 1619.9 eimm. :..: ID D 2 i O FS Z n _i 0 ® �= �L C D _� FS COLOR TREATME T FS 1.==141( V L _ ri i 1 .�' 1 WOMEN'S SHOES / - i ca p 494.5 WOMEN'S SHOES 7 SALES SUPT, i.,. 686.Q FS STOCK CLARlNS 665.1 � '- ® FS I INTIMATE APPAREL CENTERCORE SUNGLASS HUT GENERAL OFFICES ail 2 2589.1 294.6 fi 13.5 79.6 \ \ COLOR/TREATMENT I GSM OFFICE FS IIPMEIMMIlSILVER JEWELRY nins ... � r1A Ois :•- .:si L'j•1• . m • I-If - ' I •IF- KESS ACCE •ORI 664,7 ■ „1 ■ ti s Ni I438.7 ID „ p i ■ ■ • ■ ■ 1 ‘ a ■l r♦k 7% 13 p i II� �1 IDOOR POCKET FS am ma I 64. ■4 Iituti E. , iiil 991.9 ��1FS S COLOR TREA M NT irr,•BLDG. REQ. _ 1w ^Li--, HANDBAGS SLG HANDBAGS SLG I J•0r I ■�l/ 662.5 BLDG. REQ. OLAP .IEC Revisions; 506,b1431.5 WATC ESCALATOR ��� SALES SUPT. ENTRANCE / VESTIBULE H 749.8 ❑ I v1 I I 174.2 JARDEN� .uuvu�a...a/11;m ��' J FS Mark Date By 1484.6 :_� 216.7 I II AISLE CIRCULATION 173.2 `I HANDBAGS SLG J t .�,����� o ■■ o ■■■■■■■■ r FRAGRANCES 270 2 1 12-2-16 STAFF c. �� 1395.5 n r ' ! 1 - ��MT 'II :■■■■■■��� Via. ._.. 'O MENS4 �� �. - +• 90%REV(EW SET :I \ `ES Imo7. im ' _COLOR/TREATMENT SALES SUPT. J I !_� ■ SA1 11;UYII i.. 4 z o FASHION JEWEL•Y .. >, �� • g'-- LOCATION OF POS/DATA N 1I I / ��. `90.9 5 `���1 34 pE CIRCULATION I'SHIS +t 1, 34.0 FS 1- z M Q / INE W - j I/IW_- ►I :- ROOM ON 2nd FLOOR. w FRAGRANCES ® ,� ' D� 1 L " `' ' • 7 � iil■iAiiir��( ��� I_ 1599,4 40, _� T I C ASHION WATCHE I• ■ a WOMENS SALES SUPT, FS ® 51 , �--� 21���� ESCALATOR 111'77-rir".9.-L- II_ �. A AISLE CIRCULATION FS FS83DBAGS 5LG Iamp ' 223,4;`y �I-. . LL.I`.3. yyl.�' DOOR POCKET 239.7 HANDBAGS SLG HANDBAGS SLG 1 1 ' 1 1 I 1..1 ' '��4 it * „ _ `J 1403.9 8 I 1 e I I M 1 • r.` . . ■ , 49) I 11 Il LOCATION OF \ E CI , n ■ 1 �' ' /1:1 L SANITARY AND VENT = p ■ ■ 1 � 1 i �✓ ■ n �� • 1-I PA., , I I ' FS •�r♦• _ ■ • _. .. II BLDG. REQ. SALES SUPT. • ` ` ca F=L=a- IIMI C3 TELEPHONE / ELECTRICAL CLOSET �� Ire T I=-.1 ;■.■t9 F.�� 101.5 0 UNUSED / VOID SPACE � \ / \ /F R \ 678.5 FS \ FS 156.9 FS / COLOR/TREATMENT READY TO WEAR RTW COLLECTIONS PETITES SPORTSWEAR 678.8 / FS 921.2 849,6 LOCATION OF 1- . aha! 1960.0 FS / COLOR/TREATMENT COLOR/TREATMENT �1 WATER LINE �, PETITES SPORTSWE'R 843,1 I� 71 41 I 11 1151.2 E R. Architect/ Engineer of Record 1104.0 I I CLINIQUE ESTEE LAUDER 9 -null o ,I• • ❑ ® FS ® ® © J READIr 111 4Y TO WEAR Fit. 13 ■ qii FS ACTIVE 14$,�(�! 1 \ Al \ - 1\ LOCATION OF PROPOSED 2315.0 if F•R `�'J qiiR. NEW LENS CRAFTERS PAD lip gr ■ READY TO WEAR I, / 173.0 F5FS i SALES SUPT. F.R.I 'I \ / tii. RTW COLLEC ION'. RTW COLLECTIONS FS UNUSED / VOID SPACE READY TO WEAR 1395.4 124.9 ❑ LJ • 'ALES SUPT. � ,,��,, \ ■ FS MPULSE ■ \ n II 2350.0 CASUAL pSPORTSWEAR FS -J 22.4 r. I- I L UNUSED / V,ID SPAL`n - SALES SUPT. / 94.7 2323.6 *. CASUAL SPORTSWEAR UNUSED / VOID SPACE I' 1 2086 0 48,0 Sea \ �/ FS RTW COLLECTIONS /� �� 4.41 �� WOMEN'S SPORTEW AR 1 J FS FS FS 1900.0 • 411, j��/ito, 1106.4 1 F5 1' ACTIVE IMIPULSE FS \A I '/E 729.1 980.9 IMP�� 1 iii 1.1 "'� r .,l� 7 f COATS/SWM vr' '�+l 1 //�� 9� SALES SUPT, FS 3458.6 125 ••,q GENERAL STORAGE lV I� SUITS 0 0 0 * ❑ * 0 ❑ 0 0 i f // 123.4 ` 357.8 Z J' SALES SUPT. /W �!O SALES SUPT. tria \ / \ / \ / \ / 2 _ 10NU8SED / VOID SPACEOR GON HALL FS 1 / _` �#4 2,00 56.8 DRESSES . : : • \ /0'�f' 8, 2. 334.4 F5 FS 14 E L RQ� ki / N / RTW \ \ \ FS \ CASUAL SPORTSWEAR IMPULSE a-- l 2 COLLECTIONS 1524.9 476.6 EXPIRATION DATE 12/31/2016 / _ _ ES 672 5 CASUAL SPORTSWEAR Yr FS❑ ■ 0 DRESSII> [4] F5 r�;�� ' 0 1248.9 L l 0 ❑■ BLDG. REQ. �., FS 1159 3 II;II TELEPHONE / ELECTRICAL CLOSET WOMEN'S SPORTSWEAR WOMEN'S SPORTSWII� CAREER orTswEtri _ 204.2 678.3 FS ' 1475.4 FS F5 1700.0 II II - F.R. 1. Architect/Engineer Job Na SUITSLila - WOMEN'S SPORTSWE CAREER SPORTSWEAR READY TO WEAR I 912.9 250.7 \ 755.5 / \ / 1 544.4 O I v SALES SUPT. \ / III FS �� Nextore Store Design Revision No.: LOCATION OF ELECTRICAL. \ f UNUSED / VOID SPA FS CASUAL SPORTSWEAR SALES SUPT, 177.4 RTW COLLECTIONS 2603.1 SALES SUPT. 1 , UNUSED / VOID SPACE ROOM FOR SERVICE TO I 1108.8 H ALL ' 24.9 REV e LENSCRAFTERS. FS FS 48.3 11►„ .r t� 1 1=1 0 _ ■ DRESSES 0 0 SUITS a FS M 0 0 0 I_ : ! SALES SUPT.. FS j { WOMEN'S SPORTSWEAR P 2148.2 1034.3 CAREER SPORTSWEAR MI-- DISPLAY / VISUAL U 739.7 121.3 Nextore project =1 2166.0 �•' �� BLDG. REQ. Number 74095 4 �• � T `�• S AIRS +• BLDG. REO. F5 p 367.4 UP LensCrafters Design Type: F.R. 111 I1 ' � *�1 , l�l ; 1 J I ��, CASUAL SPORTSWEAR ,�,� READY TO WEAR �� _ � ��►��► r I� + STAIRS UP 786.1 ,. O =='[.:2 GLOBAL 664.9 =Z I l' rI la �� "141 'BLDG. REr301.4 I�� / 1�llo O i_� STAIRS • ► ► • ; - Ilill/.� . s . ► ► � ' 1 ������ 4 � � )I$SUE� FSR: . AI .I �l �. - 1 565.2 7 - �=�== Nowlop- 111 'VW�i ■ _■_ ■_�_��_ ■•�# �;I ■7 �� -•• ••11.10 ►r Client Review ❑LL Approval .1'' f ❑DOB Permit ❑Bid SALES SUPT. ENTRANCE #5 F.R. F STOCK STOCK F.R. ., W ��, - / F.R. B1110 RE{] AISLE CIRCULATION 10% READY TO WEAR I `'" READY TO WEAR READY TO WEAR READY TO WEAR READY TO WEAR \j READY TO WEAR RESTROOM - WOMEN'S ODOB Permit-Re-Submit ❑Construction 110.3 306.5 EMPLOYEE 922.7 236.9 419.3 296.2 \ J215.0 405.0 ENTRANCE W WW__ - BLDG. REQ. SALES SUPT. SALES SUPT. BLDG. REQ. SALES SUPT. SALES SUPT, 2 MECHANICAL, PLUMBING, & ELECTRICAL DRAWING INDEX 'OVERALL EXISTING ENTRANCE / VESTIBULE GENERAL STORAGE HALL SPRINKLER ROOM UNUSED / VOID SPACE OFFICE - DM 119.0 49.3 39.3 119.2 102,9 122.0 FLOOR PLANS ENTRANCE #4SHEET DESCRIPTION SALES SUPT. 10% BLDG. REQ. MPE100 MECHANICAL,PLUMBING AND ELECTRICAL OVERALL BUILDING PLANS SALES SUPT. AISLE CIRCULATION ENTRANCE / VESTIBULE H200 HVAC DEMOLITION AND NEW PLANS UNUSED / VOID SPACE 159.3 276.4 P200 PLUMBING PLANS AND RISERS 27.9 E100 ELECTRICAL SPECIFICATIONS, SYMBOLS AND DEMOLITION PLAN PLAN NORTH E200 ELECTRICAL LIGHTING,POWER AND LOW VOLTAGE PLANS Date Sheet EXISTING FLOOR PLAN - FIRST FLOORCI) E300 ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULE 12-2-16 Drawn By Ci) STAFF MPE100 SCALE: 1'=20`0' Checked By 2-LCM-MPE100-REV0.0 MR 1 HVAC SYMBOLS 2 GENERAL NOTES ND(TORE 1 •4p00 Lwcot c Place,Mason,OH 45040 •41(513)765-E0�6 71 A. THE CONTRACT DOCUMENTS REFLECT A SYSTEM DESIGNED AROUND SPECIFIC REFERENCE PRODUCTS,THE I. DUCT SIZES INDICATED REPRESENT CLEAR INTERIOR SHEET METAL DIMENSIONS. •4000L erya,�k,eaMaon,Granby,451140 6 •.1(516)393-2484 El PATTERN.TTEY AIR NODIFFUSER -ARROWS INDICATE SELECTION OF WHICH HAS IMPACTED THE DESIGNS OF OTHER TRADES.IF ALTERNATE MANUFACTURERS ARE PATTERN SHOWN EQUALS 4-WAY. OR AS NOTED SUBMITTED OR BID,IT IS THE RESPONSIBILITY OF THIS G.C.TO COORDINATE ALL DIFFERENCES AND IMPACTS J. ALL DUCTWORK CONCEALED ABOVE CEILINGS, AND ALL OUTSIDE AIR DUCTS,SHALL BE EXTERNALLY STORE #8753 re\ WITH ALL TRADES PRIOR TO BID,INCLUDING COSTS ASSOCIATED WITH REQUIRED CHANGES TO OTHER TRADES. INSULATED. IF DUCTWORK IS RUN IN A NON CONDITIONED SPACE ALL DUCTWORK MUST BE INSULATED WITH ® RETURN AIR GRILLE NO EXTRAS WILL BE ALLOWED FOR CHANGES REQUIRED TO OTHER TRADES IF ALTERNATE EQUIPMENT IS BID OR 2" FIBERGLASS INSULATION AND VAPOR BARRIER. Washington Square INSTALLED AT THE G.C.'S OPTION. 9300 SWWashington Square Rd. K. BRANCH DUCTS SERVING DIFFUSERS SHALL BE SIZED TO MATCH DIFFUSER NECK SIZE INDICATED. Tigard, R 97223 12"O ROUND DUCTWORK. DIAMETER IN INCHES. B. EXISTING MECHANICAL INFORMATION IS BASED ON LIMITED EXISTING BUILDING DRAWINGS AND FIELD WORK. THE G.C.SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY. NO ADDITIONAL COMPENSATION L. ALL ROUND DUCT ELBOWS SHALL BE LONG SWEEP,1-1/2 TIMES THE CENTERLINE RADIUS. 20x12 + RECTANGULAR DUCTWORK. SIZE IN INCHES, SHALL BE ALLOWED FOR REVISIONS TO THE DESIGN TO CORRECT FOR EXISTING CONDITIONS NOT AS FIRST NUMBER IS SIDE SHOWN. INDICATED ON THE PLANS. M. G.C. MUST REPLACE ALL AIR FILTERS IN HVAC UNITS WITH NEW CLEAN FILTERS BEFORE AIR BALANCING AND Construction fon PRIOR TO FINAL TURNOVER TO TENANT. DIFFUSER/GRILLE LABEL: C. G.C. SHALL NOTIFY TENANT,ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR INCREASE THE A B A-TYPE/DESIGNATION SCOPE OF WORK FROM WHAT IS DESCRIBED IN THE DOCUMENTS. N. IT IS THE G.C.'S RESPONSIBILITY TO ENSURE THAT THE MECHANICAL COMPONENTS ARE INSTALLED AT C B- NECK SIZE(INCHES) LOCATIONS AND ELEVATIONS WHICH MAKE THEM READILY AND SAFELY ACCESSIBLE FOR ROUTINE C -AIRFLOW(CFM) D. G.C. SHALL BE RESPONSIBLE FOR ALL CUTTING/PATCHING RELATED TO THEIR WORK. MAINTENANCE WITHOUT REQUIRING ANY EXTRAORDINARY MEASURES. S POINT OF CONNECTION -NEW TO EXISTING E. IF SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM, CONSTRUCTION MATERIALS ABOVE O. THE TENANT RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS AND SPECIFICATIONS. V) CEILING SHALL BE NONCOMBUSTIBLE,OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT SHOULD THE TENANT FIND CORRECTIVE WORK NECESSARY,HE WILL NOTIFY G.C.OF SUCH WORK IN WRITING + L MANUAL VOLUME DAMPER FINISH RATING.WIRING SHALL BE LABELED PLENUM RATED TYPE PER NEPA 70. AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK IS DEEMED TO BE Ce cD NECESSARY,THE COST OF REINSPECTIONS WILL BE BORNE BY THE G.C.IF WORK IS REQUIRED BY TENANT IN CD_ F. COORDINATE LOCATION AND ELEVATION OF MECHANICAL WORK WITH ALL DUCTWORK, LIGHT FIXTURES,AND ORDER TO IMPROVE,CHANGE OR CORRECT AIR CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART O d OTHER CEILING BUILT-IN FIXTURES.CONTACT ENGINEER OR ARCHITECT IMMEDIATELY SHOULD ANY CONFLICT MALFUNCTION,WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE s- a (1) - 0 SHEET KEYNOTE REFERENCE ARISE. STORE, G.C. SHALL BE DIRECTED BY TENANT TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES Eno. 0 0 EVIDENT THAT THE G.C.CAN NOT ACCOMPLISH THE TASK,THEN AFTER 72 HOURS OF WRITTEN NOTICE,THE fp .- >,....... G. MOUNTING OF ALL EQUIPMENT, DUCTWORK AND PIPING MUST BE DONE PER BUILDING GUIDELINES AND LOCAL TENANT MAY AT HIS DISCRETION TAKE OVER SUCH WORK AND BACK CHARGE THE G.C. FOR ANY CORRECTIVE CODES AND INDUSTRY STANDARDS. COORDINATE INSTALLATION OF EQUIPMENT SUPPORT WITH BUILDING WORK THAT WAS REQUIRED DUE TO LACK OF PERFORMANCE,WORKMANSHIP AND/OR ADHERENCE TO PLANSO C MANAGER AND NEXTORE REPRESENTATIVE. AND SPECIFICATIONS. x< 0 0 J ai (A H. NO PVC PIPING ALLOWED IN PLENUM AREAS. P. DUCTWORK SHALL NOT BE ROUTED OVER ELECTRIC PANELS AND TRANSFORMER. 2 N. 1-LCM-H200-REV 0.0 2-LCM-H200-REV 0.0 Ce a--S v 0( 4.. 111=0) 145 (� L 1717 L o ?' 3 H E - 3 REGISTER AND DIFF SCHEDULE@ KEY NOTES – MECHANICAL PLAN � :oa� 0 Q z t.71 x 1. RETAIL AREA OPEN TO MACY'S HVAC SYSTEM. NO WORK REQUIRED IN THIS AREA. _0 J 2 TAG SERVICE MOUNTING MFR MODEL MODULE SIZE FINISH NOTES 2. EXISTING STORE SUPPLY AIR DUCTWORK TO REMAIN. Z cn C) Air 0 3. CONNECT NEW SUPPLY AIR DUCTWORK TO EXISTING STORE SUPPLY AIR DUCTWORK AS < Q INDICATED. SUPPLY MATCHSTD.WHITE 4. PROVIDE DAMPERS PER DETAIL IN DESIGN MANUAL. PROVIDE CABLE OPERATED DAMPERS WHERE Si AIR CEILING TITUS TMS 24' X 24' FINISH 1 _ DAMPERS ARE INSTALLED OVER GYPSUM BOARD CEILING. R1 RETURN MATCH TITUS 50F 24' X 24' STD.WHITE 5. PROVIDE DUCT TAKE OFFS PER DETAIL. HIGH EFFICIENCY FITTINGS SHALL BE USED. SEE DETAILmil 3 AIR CEILING FINISH IN DESIGN MANUAL RETURN MATCH STD,WHITE 6. INSULATE ALL SUPPLY DUCTWORK PER APPLICABLE ENERGY/MECHANICAL CODE-MOST R2 AIR CEILING TITUS 50F 12' X 24" FINISH RESTRICTIVE TO GOVERN. 7. EXISTING SUPPLY DIFFUSER AND DUCTWORK TO REMAIN, NOTES/ACCESSORIES 8. RELOCATE EXISTING RETURN GRILL TO NEW LOCATION. 1. PROVIDE NECK SIZE TO MATCH SUPPLY DUCTWORK ON DRAWINGS. I I I I 1 \II 2. TITUS CHOSEN, EQUALS ALLOWED. II MI I Revisions: 3-LCM-H200-REV 0.0 4-LCM-H200-REV 0.0 Mark Date By X0 A 12-2-16 STAFF ! J 90%REVIEW SET I I I I A RETAIL SALES AREA 100 -3 ® A CLG. HT.= 12'-0" 1 I I I A A O IN Architect / Engineer of Record O '4 12" DIA ( I o I I — _.z__--i_,-. _-_-__ I1^ SJ 33- �1 W W CONTACT LENS ' ROOM Seal 101 �`-} I S_1 I 0 I Dip!, 1 9 CLG. HT.= 10'-0' �j 125 iA�T I KX #40)74116Ar• >J 8" DIA OPTICAL STATION 00 r , --,102 . . _. I f I > HI 2/1/14 CLG. HT.= 10'-0" (TYP) I I OREGON 0 I I ., 44y 8 1001 cS -� - - - - , 0 4EL Rpt --10" DIA I S-1 1 " X EXPIRATION DATE: 12/31/2016) 125 , PRETEST I Q© �� i Architect/Engineer Job No: 103 8 DIAX 0 0 CLG. HT.= 10'-0" 8 (TYP) 00.' :E2': a : Nextore Store Design Revision No.: =2 REV 0.0 Z N9-iN31 0£HD-D1 OEHD-D1 Lam', II "DIA Nextore project i8 Number 74095 R-2 EXAM J 8"DIA I I I I LensCrafters Design Type: ROOM —/// S-1 GLOBAL 104 CLG. HT.= 10'-0" 0 ISSUED FOR: I<) I(, ®Client Review 0 LL Approval _ DDOB Permit 0 Bid 0 `� D DOB Permit-Re-Submit 0 Construction I_ y I >~ L 13 Title 7,1 H HVAC PLAN PLAN NORTH HVAC PLAN Date Sheet 0 12-2-16 SCALE. 1/4'=1'0' Drawn By STAFF H200 Checked By MR I PLUMBING EQUIPMENT SCHEDULE GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND 5 ea KEY NOTES - SANITARY/VENT PLAN NDCFORE MAINTENANCE INSTRUCTIONS. -1 1. EXTEND NEW SANITARY PIPE TO LOCATION INDICATED ON MPE-100 AND MAKE CONNECTION TO EXISTING 1.11111.1.1111. SANITARY PIPE. 1 � •40001uxot Ica Place,Mason,OH 45040 •+1(513)765-f000 SUPPLIED/ MFG./ MODEL # { 2. CONNECT NEW VENT TO EXISTING VENT MAIN IN LOCATION INDICATED ON MPE-100. L`./ I I I •6CreameyB fast Granby,CT 06026 •"1(516)393-2464 MARK DESCRIPTION INSTALLED BY PHONE # COLOR REMARKS 3. ALL PLUMBING PIPING TO BE CONCEALED. I \ SINK: CLF-ADA-10 0 — I \ STORE #87 5 3 SK-3 ROUND SINK FOR T/PC JUST SINKS FAUCET:JUST#J-981 GC TO MAKE FINAL CONNECTIONS.INSTALL MIXING VALVE BELOW CONTACT LENS (847)678-5150 FIXTURE,CONNECT TO SUPPLY PIPING AT FIXTURE,SET WATER TEMP.@ Washington Square 110°F. 9300 SW WashSquare ton S uare Rd. SK-7 30" SINK FOR BOH-SU30 T/PC ELKAY SINK: LLVR2117,STRAINER: *SELECT 1-HOLE DRILLING CONFIGURATION.G.C.TO MAKE FINAL 1135, FAUCET:DELTA � I I I Tigard, OR 97223 1135, FT CONNECTIONS.INSTALL MIXING VALVE BELOW FIXTURE,CONNECT TO SUPPLY PIPING AT FIXTURE, SET WATER TEMP.@ 110° FIF REQUIRED. I Construction for. IWH-1A TANKLESS WATER HEATER PC/PC EEMAX MODEL#SP2412 SINGLE POINT, 120 VOLT, 1 PHASE, 60 HZ,2.4 KW,33°TEMPERATURE RISE. IWH-1B MOUNTED BELOW SINKS IN CABINET. SEP-1 SEWAGE EJECTION PUMP PC/PC SANIFLO SANIVITE —SELF CONTAINED SEWAGE EJECTOR PUMP AND BASIN. CORD AND PLUG CONNECTION TO GFI OUTLET I ! I AND RESERVOIR REQUIRED. 120V, 4.5 AMPS,3/10 HP. UNIT IS APPROXIMATELY15°X 8"X 11° HIGH(WITHOUT PIPING). PROVIDE SANIALARM WITH UNIT AND INSTALL. PURCHASE PUMP FROM SELECTED VENDOR: SANIFLO, DISTRIBUTER TO 5-LCM-P200-REV 0.0 CONTACT: THE DISTRIBUTION POINT(ALABAMA). CONTACT NAME: ROB FOSTER; CONTACT PHONE: 1-866-837-2550; CONTACT EMAIL: ROB n©THEDISTRIBUTIONPOINT.COM OR ' RANSON@THEDISTRIBUTIONPOINT.COM Q"1-o I I I I pQ Cr) I . _ uO r1H I I-1- oe c s).> x 0 J \ ,l p j> cu N,RETAIL SALES AREA I V� .EXISTING 1 WATER V 100 LINE t+— tt5 L_ P i CLG. HT.= 12'-0" I 0 t1 co I U3 F E NEW ISOLATION I I I I }' VALVEI p z 1/2" \ 1f I 2 �4 L .40( =ir) J p SK3 W < a O I 1 `� U IIf : NMI 2 IWH-1B T I , ��� I t6 EXIS 6-8"SANITARY I i__ �:, i_I Ji EXISTING 1"WATER PIPE I LINE I 2"_�� . . 01 I 1 NEW ISOLATION O \\ • I I I J 1 VALVE I \ 1 112" — \ . I 1 ' `\ + _ _ _ L. Revisions: ,.\ 1 112" —""%‘..,,. I Z —— - -- Mark Date By 1/2" 2"-->' \ i) CONTACT LENS ._ 1 \ \ SK3 ( SK3 12-2-16 STAFF \ ROOM 90%REVIEW SET \\4 O 101 I I I I ! v SK7 (I \ CLG. HT.= 10'-0" ` . A 0 IWH-1A � 1 ._ -i _ ..,III F-F 1 \ I 1�__ ��BIM i_ l v i 2 1 SUPPLY ISOMETRIC ,. - z"_,, U\ 57 I 0 \\\ I OPTICAL STATION I r — — • I B SCALE NONE — I — — - — \ J 102 I I I ' ' f v CLG. HT.= 10'-0" I ( I I A I I I �o .a _ _ _ , ."_ SANITARY & VENT ISOMETRIC � A 1 PLUMBING SYMBOLS —E-_ =-= =- T A ` O •,SK3 SCALE: NONE I I I I (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) CONTACT LENS —..i.=:-1/2"—t>4-- 00 Ii I 0 ROOMPRETEST „i a IW13 �I Architect/ Engineer of Record O ELBOW UP CAP ON END UNE 101 © 0 103 I- —FL"- , gi CLG. HT.= 10'-0" CLG, HT.= 10'-0" I o O ELBOW DOWN WALL CLEANOUT ' cr I O TEE OUTLET UP CD WATER METER \-.(-/• i I I OPTICAL STATION O TEE OUTLET DOWN RD PLUMBING FIXTURES 102 r — — � h I zEa{ N» PEND-171 o€H�-1D1 �_ } SANITARY PIPING (W) CLG. HT.= 10'-0" POINT OF NEW CONNECTION �, SANITARY VENT PIPING M �— I y TO EXISTING PIPING OR SYSTEM J COLD WATER(CW) - — - — I� _i 1' EXAM I _ .. - ROOM • . Seal / , - HOT WATER (HW) VALVE 104 r / .„ 4 0/H OVERHEAD I- DOWN I • 00 CLG- HT.= 10'-0" '!l DN -437"..f\\15. I 3 I : 1,Op ,�4 U/G UNDERGROUND PRETEST ,�1 �� 2 SAN IN WALL I O << E . f �U H — r''1 °� EXISTING 103 > .11 ly 1 P Ex - 4) i I I I �it� 1-LCM-P200-REV 0.0 CLG. HT.= 10' 0" o r ll� 4( _ a p Y- w I i I a I7 OREGON 4, if/014/}' 8 z�a�wD1 oEl D-D1 OND-171 H '-' , 2 44 2 STANDARD P.D.I. WH 201 WATER HAMMER ARRESTER SCHEDULE PLAN NORTH AEL SANITARY AND VENT PLAN P.D.I. UNITS AA 0 0 F De V EXPIRATION DATE: 1 /31/2016 EXAM SCALE: 1/4•=1'-0• FIXTURE UNITS 1-3 441 12-32 33-60 61-113 114-154 155-330 ROOM H, Architect/Engineer lob No.: 104 __ O. es 2-LCM-P200-REV 0.0 CLG. HT.= 10'-0" Q — I"- 6 KEY NOTES - SUPPLY PLAN Nextore Store Design Revision No.: 3 PLUMBING CALCULATIONS - 1. CONNECT TO EXISTING DOMESTIC WATER PIPE. G.C.TO COORDINATE WORK WITH LANDLORD FOR REV O.O "' IWH-1A F" WATER TIE IN. SEE MPE-100 f - 2. REFER TO DETAIL IN DESIGN MANUAL FOR WATER HEATER PIPING DETAIL. PLUMBING FIXTURE QTY. SAN F.U. EACH SAN F.U. TOTAL C.W F.U. EACH WM. DMD. TOTAL SK7 Nextore project 3. CONTRACTOR SHALL RUN ALL PLUMBING PIPING CONCEALED. Number 74fl95 0— a 4- EXISTING SPRINKLER HEAD TO REMAIN. SINK(5K3&SK7) 2 2.0 4.0 2.0 4.0 ,# LensCrafters Design Type: 5. EXISTING SPRINKLER HEAD TO BE RELOCATED OR PROTECTED. VERIFY WITH G.C. ALL WORK IS TO BE COMPLETED BY THE LANDLORD'S SPRINKLER CONTRACTOR AT THE GC'S EXPENSE. SPRNKLER GLOBAL -V//' 1���/ /; ,� �/,� I CONTRACTOR TO INCLUDE ALL WORK, INCLUDING BUT NOT LIMITED TO,LANDLORD COORDINATION, TOTALS /� i 4.0 '� ' ' ' 4.2 SUBMITTALS AND CALCULATIONS, DRAIN DOWNS, ETC.,AS REQUIRED TO COMPLETE THE SPRINKLER ISSUED FOR: SYSTEM REVISIONS TO SUPPORT THE NEW LENSCRAFTERS. >A Client Review ❑LL Approval SERVICE CONNECTION SIZE SAN. 2'° WATER 3/4" 6. CONNECT COLD WATER LINE TO EXISTING 1"WATER LINE. VERIFY TIE-IN LOCATION IN FIELD. ❑DOB Permit El Bid 3-LCM-P200-REV 0.0 ! 7. PROVIDE NEW SPRINKLER HEADS IN NEW ROOMS. ACTUAL LOCATIONS TO BE DETERMINED BY FIRE ❑DOB Permit Re Submit ❑Construction PROTECTION CONTRACTOR. ALL WORK IS TO BE COMPLETED BY THE LANDLORDS SPRINKLER CONTRACTOR AT THE GC'S EXPENSE. SPRNKLER CONTRACTOR TO INCLUDE ALL WORK,INCLUDING BUT I .. jam -•1.7‘ NOT LIMITED TO, LANDLORD COORDINATION, SUBMITTALS AND CALCULATIONS,DRAIN DOWNS,ETC.,AS Title 4 PLUMBING FIXTURE - CONNECTION SCHEDULE V REQUIRED TO COMPLETE THE SPRINKLER SYSTEM REVISIONS TO SUPPORT THE NEW LENSCRAFTERS. SANITARY AND 8. EXISTING 1"WATER LINE TO REMAIN. FIXTURE DRAIN HOT COLD VENT VENT PLANS AND PLAN NORTH SINK ®® 2" 1/2" 1/2" 1-1/2" 6 LCM P200 REV 0.0 WATER SUPPLY AND FIRE PROTECTION PLAN DETAILS ELECTRIC WATER HEATER WH 3/4" 3/4" 1 Date 12-z 16 Sheet SCALE: 1/4'=1'-0" Drawn By NOTE:(SKI THRU 7)CONTRACTOR WILL BE REQUIRED TO FURNISH ALL LABOR,PIPING MATERIALS AND APPURTENANCES NECESSARY TO STAFF P200 COMPLETE INSTALLATION OF SINKS,FAUCETS AND DRAINS FURNISHED BY OWNER. Checked By 4-LCM-P200-REV 0.0 MR P- NEXTORE w\/./. , .o ...... *4600 Luxottica Place,Masor4 OH 45040 •+i(513)765-E000 O 6 Creamery Broc*,East Granby,CT 0E626 8+1(516)393-2484 I ` I I 0 j � ®U STORE #8753 _ _ _ _ Washington Square - 9300 SW Washington Square Rd. T Tigard, OR 97223 1 III OI EwA � I Construction for. H + CO 0 I I �® 0OI ' 1 (,n 1 ELECTRICAL SYMBOLS 2 @ KEY NOTES - ELECTRICAL DEMOLITION PLAN 1ce c,..,,_ (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) 7 I D CD + 1. DISCONNECT AND REMOVE EXISTING STRIP FIXTURE AND RETURN TO MACY'S OPERATION. r- 1 I EVA I Ewa ,® 2 O cn HOMERUN TO PANEL AND CIRCUIT INDICATED 2. DISCONNECT AND REMOVE EXISTING 2X2 FIXTURE AND RETURN TO MACY'S OPERATION. O �:.�1 u # XX-## I o o ID® O 3. EXISTING SPEAKER TO REMAIN. 0 — I 1 PANEL CIRCUIT >., O O 0 4. EXISTING RECEPTACLE TO REMAIN. ——— — INFLOOR/UNDERFLOOR CONDUIT/WIRE I ®O 5. DISCONNECT AND REMOVE EXISTING TRACK AND FIXTURE AND RETURN TO MACY'S OPERATIONS, J JUNCTION BOX I \\\ I 3 j n- 6. EXISTING LIGHT FIXTURE IS TO REMAIN. Ce -1—" V foC DUPLEX RECEPTACLE 125 VOLT,2 POLE,3 WIRE,GROUNDING TYPE,20 T 7, DISCONNECT AND REMOVE EXISTING RECEPTACLE, RECONNECT ELECTRICAL TO KEEP EXISTING SYSTEMS IN OPERATION. p Ui AMPERE,MOUNTED AT 18"AFF UNLESS OTHERWISE NOTED: 10 CL ID "2'INDICATES CIRCUIT NUMBER I t L "E"EXISTING TO REMAIN E 'WP" INDICATES WEATHERPROOF COVER 1 EWA SP o Z "D" DEDICATED CIRCUIT IT 6 1 6 'va x "GEL" INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE Q Q INDICATES RECESSED D1 ��J} Z - 'R' -I DOUBLE DUPLEX RECEPTACLE-125 VOLT,2 POLE,3 WIRE,GROUNDING � `" 7 p TYPE,20 AMPERE,MOUNTED AT 18"AFF UNLESS OTHERWISE NOTED. T I EVA •O6LL1 < . 1-) 4( til >1 -u DUPLEX RECEPTACLE-125 VOLT,2 POLE,3 WIRE, 20 AMPERE MOUNTED I. ro IN FLOOR BOX. 6 J "CLG"INDICATES MOUNTED IN CEILING I O I I O we® 6'Z Z," COMBINATION DUPLEX RECEPTACLE AND VOICE/DATA OUTLET MOUNTED IN FLOOR BOX. Ill=* DOUBLE DUPLEX RECEPTACLE-125 VOLT,2 POLE,3 WIRE, 20 AMPERE 2 LCM E100 REV 0.0 J. EX/A EVAI EVA OA MOUNTED IN FLOOR BOX. ,� O El tCOMMUNICATIONSFLOORBOX 3" GENERAL NOTES 1 i 1 !�1 I T Revisions: + SWITCH-SINGLE POLE TOGGLE TYPE-120/277 VOLT,1-HP RATED,20 I Mark Date By AMPERE, MOUNTED AT 48'AFF UNLESS OTHERWISE NOTED: A. IT SHALL BE THE E.C.1S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE.THE E.C. "3'INDICATES THREE WAY SWITCH SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. Fr /,7\1 Q 12-2-16 STAFF "4"INDICATES FOUR WAY SWITCH `J I 90%REVIEW SET 'C"INDICATES SWITCH MOUNTED 8"ABOVE COUNTER B. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. I "OS"INDICATES OCCUPANCY SENSOR SWITCH EXIT/EMERGENCY LIGHTS AT DOOR TO NON-SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED "D" INDICATES 0-10V DIMMER SWITCH-WATTAGE AS INDICATED ON PANEL ABOVE DOOR.IF PLAN LOCATIONS ARE NOT ACCEPTABLE,IMMEDIATELY CONTACT LUXOTTICA PROJECT r-- + I I I A SCHEDULE.EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE MANAGER FOR DIRECTION. I NEUTRAL CONDUCTOR EwA VA [EVA "M"INDICATES A MASTER SWITCH THAI OVERRIDES THE OTHER SWITCHES CONNECTED C. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, E.C. SHALL ARRANGE CIRCUITS TO AVOID THE TO 1T, USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS.THE USE OF JUNCTION BOXES ABOVE DRYWALL Q1 /� ® /� A "OSD" INDICATES 0-10V DIMMER SWITCH WITH INTEGRAL PIR OCCUPANCY SENSOR- CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR 1 �J �/ WATTAGE AS INDICATED ON PANEL SCHEDULE.EACH BRANCH CIRCUIT SHALL GRILLES OR ACCESS PANELS AS LOCATED ON PLANS.IF PLAN LOCATION IS NOT ACCEPTABLE, —?. - INCLUDE A SEPARATE NEUTRAL CONDUCTOR. 1 OR 3 WAY AS INDICATED. IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION. I + 0:-.) CEILING MOUNTED OCCUPANT SENSOR D. E.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION I PERIOD. 1 AD LIGHT FIXTURE:"AD" INDICATES FIXTURE TYPE'a" INDICATES SWITCH I~ OI /S _ a CONTROL.REFER TO LUMINAIRE SCHEDULE FOR DESCRIPTION. E. LIGHTING CIRCUITS UP TO 100'-0' IN LENGTH SHALL UTILIZE#12 CONDUCTORS MINIMUM.LIGHTING — I. 1_ TL CIRCUITS FROM 101,-0" TO 150'-0" IN LENGTH SHALL UTILIZE#10 CONDUCTORS MINIMUM. LIGHTING y TRACK AND TRACK MOUNTED LIGHT FIXTURE(DESIGNATIONS VARY- CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE#8 CONDUCTORS MINIMUM. LIGHTING F' T #T-S SEE PLANS) CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE#6 CONDUCTORS MINIMUM. 1 I SP 1 •4 OD RECESSED DOWNLIGHT. DESIGNATIONS VARY-SEE PLANS. F. E.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY )— L`1� r —-, Architect/ Engineer of Record NEXTORE. E.C.IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL DIRECTIONAL FIXTURES AFTER e.L`1 INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS wA 6 EwA ILLUMINATED"EXIT"SIGN LIGHTING FIXTURE.CEILING MOUNTED OR I ® WALL MOUNTED.PROVIDE DIRECTIONAL ARROWS AS INDICATED ON MAY VARY,]F THIS IS THE CASE,CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT H + c......",.1 F FLOOR PLANS. SPECIFICATION OF LIGHTING FIXTURES.IF THE CEILING SYSTEMS ARE FIRE RATED, E.C. SHALL CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH LUXOTTICA. E° /7\ I I I I •0 TC LIGHTING TIME CLOCK G. E.C.SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FORA FULLY COMPLETE AND OPERABLE 0 ? I SYSTEM. j 1 V COMBINATION VOICE/DATA OUTLET MOUNTED AT 18"AFF UNLESS H. E.C.SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK 1 OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING PRIOR TO CONNECTION. AND 3/4'CONDUIT TO ABOVE THE ACCESSIBLE CEILING.'W"INDICATES WALL MOUNTED AT 54"AFF,'C'INDICATES MOUNTED 8'ABOVE 1. ALL MOUNTING HEIGHTS FROM THE CENTERLINE OF THE BOX TO THE FINISHED FLOOR ARE AS FOLLOWS, I 0 Q COUNTER. UNLESS NOTED OTHERWISE ON PLAN:SWITCHES-48", ELECTRICAL/TELEPHONE/DATA OUTLETS-18", TOP ,. �I I I I Seal TELEPHONE OUTLET MOUNTED AT 18'AFF UNLESS OTHERWISE �:/ r , pOp 4 , ' NOTED.PROVIDE SINGLE GANG Box WITH FEASTER RING AND 3I4" OF PANELBOARDS-6'-6",TIMECLOCKS-5'-0". FOR ALL LENS PROCESSING ROOM OUTLET MOUNTING I I IIII 'HEIGHTS SEE EQUIPMENT WIRING SCHEDULE. 1 EwA EXIA '.'YCONDUIT TO ABOVE THE ACCESSIBLE CEILING. "W"INDICATES WALL L: J %y , � ♦�' MOUNTED AT 54"AFF, 'C"INDICATES MOUNTED 8"ABOVE COUNTER, J. FLEXIBLE CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO MILLWORK,INTERIOR LIGHTING '' + � ! "P"INDICATES PUBLIC TELEPHONE OUTLET-COORDINATE MOUNTING FIXTURES,AND EQUIPMENT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE 12`-0". I _� V O Ms/('/101' �,' DATA OUTLET:MOUNTED AT 18"AFF UNLESS OTHERWISE NOTED. K. IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS,THE GENERAL CONTRACTOR WILL BE 4I I I I /i PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4"CONDUIT TO RESPONSIBLE FOR OBTAINING "AS BUILT" DRAWINGS FROM THE SUBCONTRACTORS AND SUBMITTING O1 g IIS ABOVE THE ACCESSIBLE CEILING.'W' INDICATES WALL MOUNTED AT SAME TO NEXTORE PROJECT MANAGER. • (/ V 54"AFF, "C'INDICATES MOUNTED 8"ABOVE COUNTER.CEG INDICATES I 4 R GON1 CEILING MOUNTED. L. IT IS THE E.C.'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF CD X72 2 PORT DATA OUTLET X74 4 PORT DATA OUTLET THE SYSTEM (WITH-IN 10%). ? y $ `�� I ic�AE� O�� M. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES O1 AND ORDINANCES- �73 3 PORT DATA OUTLET \76 6 PORT DATA OUTLET 1 I I ' N. ALL OUTLETS IN THE LENS PROCESSING ROOM ARE TO BE LABELED WITH PANEL AND CIRCUIT NUMBER. 1 (EXPIRATION DATE: 12/31/2016. „-------.. SWITCHED WIRING O. THE E.C. SHALLVERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK r ,- "-. BRANCH CIRCUIT WIRING PRIOR TO CONNECTION. ®gm I EIAIEXIA EVA ArchitectJEngineerjob Nb.P, SEE DATA RISER ON THIS SHEET FOR ADDITIONAL INFORMATION. 0 _1 !/ HOMERUN '" ,� MOTOR Q. PROVIDE POWER,TELEPHONE AND DATA CONDUIT WITHIN FLOOR, BETWEEN FIXTURE AND NEAREST . I I I I �/ Nextore Store Design Revision No.: WALL AS INDICATED ON PLANS. METHOD F ING REQUIREMENTS.ALL CORE DRILL REQUIREMENTS SHALL BE VERIFIED O WITHLANDLO D CONTRACTOR RE DRILLING SHALL BE PER ISHALL SIZE CONDUIT PER — + REV 0.0 FIRE ALARM DEVICES ARE ONLY SHOWN FOR PREFERENTIAL LOCATION. NEC. PROVIDE FOR X-RAY OF FLOOR WHERE REQUIRED BY THE LANDLORD. I FINAL LOCATIONS AND QUANTITIES SHALL BE DETERMINED BY LI ANDI FIRE ALARM ENGINEER-VERIFY PRIOR TO ROUGH IN. 3-LCM-E100-REV 0.0 F' .7% I Nextore project _ �F FIRE ALARM MANUAL PULL STATION MOUNTED AT 48"AFF. 0 •. Number 74095 I I I LensCrafters Design Type: Ell FIRE ALARM AUDIO/VISUAL ALARM SIGNAL WALL MOUNTED AT 80"AFF, 4 GENERAL NOTES - FIRE ALARMI T GLOBAL VD FIRE ALARM VISUAL ONLY ALARM SIGNAL WALL MOUNTED AT 80'AFF. -.> A. MACY'S WILL PROVIDE FIRE ALARM NOTIFICATION APPLIANCES IN THE LENSCRAFTERS SPACE SUFFICIENT ISSUED FOR: 0 FIRE ALARM SMOKE DETECTOR TO COMPLY WITH CODE. ELECTRICAL CONTRACTOR TO COORDINATE WITH MACY'S FIRE ALARM ►u Client Review ❑IL Approval CONTRACTOR FOR ALL WORK ASSOCIATED WITH THE FIRE ALARM SYSTEM,INCLUDING ANY RACEWAY EVA EX/A EVA ❑DOB Permit 0 Bid 0-- FIRE ALARM SMOKE DETECTOR DUCT MOUNTED AND BOXES. _ ODOR Permit-Re-Submit 0 Construction 1-LCM-E100-REV 0.0 4-LCM-E100-REV 0.0 Title — SPECIFICATIONS, Q(;c © O SYMBOLS, AND DEMOLITION PLAN NORTH Sheet 12-2-16 ELECTRICAL DEMOLITION PLAN DrawnDate By STAFF SCALE: 1/4 =i'-0 Checked By E100 MR : 1 LIGHTING SCHEDULE , NDCRDRE 6000 SYMBOL TYPE MANUFACTURER PART-NUMBER INPUT WATTS LAMP QTY LAMP TYPE DESCRIPTION MOUNTING CEILING TYPE ' 1________—_—, , I / / ` I I •6Cre•4000 Luxottica Place,Mason Iy 450x0 •.1(SI3)76s-2464 6 Creamery Brook fast Granby,CT 0€026 •+1(516)393-2484 22ALNG LD4 35 UNV-L835-CD,- RECESSED 2X2 LED TROFFER C' I I 7 ! . .. .. U-OCC/DIMMER SUPPLIER TO PROVIDE OCC SENSORS, STORE �� AD METALUX (TOTAL QTY AS NOTED IN 34.5 N/A INTEGRAL LED,3482 LUMENS COMBINATION SENSORS/DIMMERS,AND 0-10V RECESSED ACT . Wash AD SCHEDULE NOTE#2) DIMMERS,WHIT IN COLOR,WITH FIXTURE053 Washington Square PACKAGE. SEE NOTE#2 AT BOTTOM OF SCHEDULE TL . I I , A_16 I 9300 SW Was ington Square Rd. I AD EM AD EM METALUX 22ALNG-LD4-35-UU1 -L835-CDL-U 34.5 N/A 14W EM RGENINTEGRAL D,3482 0 LUMENS LUMENS RECESSED 2X2BAETTERY BACK PTROFFER *H EMERGENCY RECESSED ACT TL • EX/A ` I Tigard, C�R 97223 - — — TL • 1\ 1 0 Gs aw9aA \\ I AEI 1 11 RECESSED EXTRUDED ALUMINUM EDGE LIT EXIT SIGN TL • \ ®m Construction for. WITH RED LETTERS FOR CEILING OR WALL MOUNTING • xz X2 LIGHT ALARMS SPLEDWRCD 3 N/A LED INCLUDED ` .. ►♦� RED LED INCLUDED.TO 8E RECESSED MOUNTED 11 • A-16 U.N.O.(FOR NYC OR CHICAGO CONFIRM WITH MANUF). I I A-3 I� ♦ I _ PROVIDE CURRENT LIMITER WHERE-R.EQUIRED. TL • . -S 1 Lit rk EX EXISTING - - - - EXISTING RECESSED DOWNLIGHT TO REMAIN IL • 0 / EX _ TL • `--� (TMP) I 1 2T-S 2T-S JUNO T2WH - TRACK ONLY-SEE TRACK HEAD 2 FT LONG,SINGLE CIRCUIT,WH1TE TRACK TL • 1 I C CD Q _ I EX/A I 11 I IL D TL JUNO T690WH 12 1 GE LED12D38W92725;12W;92 CRI, GIMBAL STYLE LAMP HOLDER,WHITE TRACK SEE FOOTNOTE 1 TL • 'I 1 14 ,9 0 *Cr) 3000K;PAR38,MED BASE O — — TL • IFiume 2LLi 4T-S 4T-S JUNO T4WH - _ TRACK ONLY-SEE TRACK HEAD 4 FT LONG,SINGLE CIRCUIT,WHITE TRACK TL • .1.-S1 I (13 O .. I .C2 ›..... TL TL JUNO T690WH 12 1 GE LED12D38VV92725; 12W;92 CRI TL • 3000K;PAR38,MED BASE GIMBAL STYLE LAMP-HOLDER,WHITE TRACK SEE FOOTNOTE 1. 1 I \ " ' x C- 0 STs ST-S JUNO T6WH - - TRACK ONLY-SEE TRACK HEAD 6 FT LONG,SINGLE CIRCUIT,WHITE TRACK 1 I 1 Q --`1 co TL JUNO T690WH 12 1'ILGE LED12D38W92725; 12W;92 CRI — l 30DOK;PAR38,MED BASE GIMBAL STYLE LAMP-HOLDER,WHITE TRACK SEE FOOTNOTE 1 A Ce `�• 8T-S 8T-S JUNO T8W"I - - TRACK ONLY-SEE TRACK HEAD 8 FT LONG,SINGLE CIRCUIT,WHITE TRACK TL •• Ex/A / dCD TL TL • A-5U �' 3 TL JUNO T690Wi 12 1 GE LED12D38W92725; 12W;92 CRI- I I O �= 3DODK;PAR38, MED BASE GIMBAL STYLE LAMP-HOLDER,WHITE TRACK SEE FOOTNOTE 1 IL •rT S 5 5 `'�, un n +=-� F E 12T-S 12T-S JUNO T12V1M - TRACK ONLY-SEE TRACK HEAD 12 FT LONG,SINGLE CIRCUIT,WHITE TRACK . C'1 ID D TL TL JUNO T690WH 12 1 GE LED12D38W92725;12W;92 CRI i Q� Z t� GIMBAL STYLE LAMP-HOLDER,WHITE TRACK SEE FOOTNOTE 1 r A-16,18,19,21,23 I A-19 A-21,23 Q 3000K;PAR38, MED BASE 1 ` * ti.) d lel- FOOTNOTES:FOOTNOTES: I I �'" r'+r yl ,� ` " I a 1.SEE PLANS FOR TRACK LOCATIONS. PROVIDE CURRENT LIMITERS AND PENDANTS WHERE CALLED FOR ON THE PLANS. ~~` {� r 2.SUPPLIER TO PROVIDE 0-10V DIMMERS WITH FIXTURE PACKAGE. SEE PLANS FOR EXACT QUANTITIES, DIMMERS TO BE INSTALLED BY ELECTRICAL CONTRACTOR Iimini co V t� TL • 1 6 1 \\ 1-LC M-A200-REV 0.0 TL • r A-18 i2 16 \\ TL • EwA 1 1- \\ M r �I I I 1 \\ I - - TO MACY'S POS ROOM TL • V O \ \\ TO MACY'S PHONE ROOM I I I I I \\ \ I -TO MACY'S PHONE ROOM TL •• \ TO MACY'S PHONE ROOM RETAIL SALES AREA ,a ji \ TO MACY'S DATA ROOM TL • 1 \ \ 100 TO MACY'S DATA ROOM TL • ` \ \ Revisions: CLG. HT.= 12'-0" 8T-S I \ \ I Mark Date By CENTER OUTLETS BEHIND CABINET,UNE UP WITHIN AN 15" LIGHT LIGHT TL • 0 HORIZONTAL SPACE,BEHIND CABINET ACCESS OPENING 1 12-2-16 STAFF ■=■ 90%REVIEW SET TO MACY'S POS ROOM ,! I • AT WORK COUNTER TO MACY'S POS ROOM I I '� � I I i 1 I A TO MACY'S PHONE ROOM I' A-1.1,E, I r- 1 TO MACY'S PHONE ROOM D DIMMER.SUPPLIED BY TENANT OSDillLiA RETAIL SALES AREA I • 0-10v, 1-WAY/3-WAY,WHITE r OSD. OCCUPANT SENSING IL •I 100 1 A INSTALL OUTLETS AT 24"AFF TO CENTERLINE. TO BAC KVVRAP - - OCCUPANCY SENSOR WALL DIMMER. SUPPLIED BY TENANT, TL • Q, CLG. HT.= 12'-0" DATA LABELING SCHEME •'M/Os SWITCH(SUPPLIED BY TENANT) I 0-10V, 1-WAY/3-WAY,WHITE TL • SEE DATA INTERCONNECTION ® ' ® I - — —OPERATES AS MASTER. I RISER ON THIS SHEET FOR /\ LI + b 0 ti ® ® • PORT LABEL DESCRIPTION UNSWITCHED CIRCUIT1 NO. INFO L — UNSWITCHED CIRCUIT I TL • I I I ; ADDITIONAL INFORMATION. 1 WALL SENSOR/DIMMER/MASTER SWITCH j ® O 0 O ® � I '01 D01 TO MACY'S DATA ROOM COMBINATION WALL SENSOR/DIMMER COMBINATION TL BTS A-2 W 0 �0 D I al Ki I 02 DO2 TO CASH DESK NOTE: ALL WIRING BY THE ELECTRICAL CONTRACTOR. IL •I ZT S��D > ® � I 1 D3 pO3 TO CASH DESK — 1 1 0045 DO4 OPTICIAN'S OCCUPANCY SENSOR SCHEMATICS Q I P I -11 ® c06 D06 SPARE D I TL TL TL TLIi I* A-18 A IAiA]AiAIJA] . SCALE: NCNJE ! I 11 D11 OPTICAL STATION 12 D12 OPTICAL STATION i • 14 D14 SPAREIT 13 013 SPARE - - _ _ I • INVINACIFiA1 CC7 — — — — - - I Architect Engineer of Record 15 D15 TO FITTING TABLE ON SALES FLOOR OSD Ci) — LCABINET IN BACK OF HOUSE _i J 16 016 TO STORE FRONT DISPLAY LF,3 CONTACT LENS s t TO SALES FLOOR GONDOLAS ' 21 021 TO DIGITAL DISPLAY AT BACKWRAP ROOM I I I ' I I FOR DIGITAL SIGNS ! 22 D22 TO DIGITAL DISPLAY AT GONDOLA � � 101 N 7 1` -1 ; � 23 D23 TO DIGITAL DISPLAY AT GONDOLA 2 LIGHTING KEY NOTES CLG, HT.= 10'-0" 1 " �� I' 24 D24 TO DIGITAL DISPLAY AT GONDOLA AD AD _ _ I 25 D25 TO DIGITAL DISPLAY AT GONDOLA 1. SUPPLEMENTAL SALES FLOOR LIGHTING IS TO BE CONTROLLED BY THE MACY'S ----� - I� 26 D26 TO DIGITAL DISPLAY AT GONDOLATIMSYSTEM. �1 0' 4 J �D-s3-voi � - I ECLOCK �+� iiihilrP6 1; AJ 31 D02 TO BOH CABINET T CONTACT LENS I II d p OPTICAL STATION ROOMii — 32 003 TO BOH CABINET 2, LIGHTING IN THIS AREA IS FROM MACY'S STORE. € I ' g`— 0 0 = (1)TOt 33 DM1 TO MACY'S POS ROOM 102 I I H 101 II ,�_�._�_� -" 34 DM2 TO MACY'S PHONE ROOM 3. LOCATION OF LIGHTING CONTACTORS. INSTALL ABOVE THE CEILING WHERE ti littP1 1 �— rx(C.I_(.1) 0 ® 35 DM3 TO MACY'S PHONE RootsPERMITTER BY CODE. SEE DETAIL IN DESIGN MANUAL.. CLG• HT,= 10' 0" 3 _I CLG. HT.= 10'-0" ( 6P) 4 II ca II 36 DM4 TO MACY'S PHONE ROOM Seal I=1 n a 4. PROVIDE 5 AMP CURRENT LIMITER FOR TRACK FROM MANUFACTURER'S -, _ — — — �#- 41 DO2 TO MACYS POSROOM SELECTION. THE ENTIRE RUN OF TRACK,INCLUDING PORTIONS _ — — — 4 .IiI A-7 ,A. S kit 42 Db3 TO MACY'S POS ROOM INTERCONNECTED WITH FIELD WIRING,IS TO BE ON THE LOAD SIDE OF THIS Mro5 • j 15 4 [SASH DESK ON SALES FLOOR J 43 DM1 SPARE CURRENT LIMITER. FINISH OF CURRENT LIMITER TO MATCH TRACK FINISH. OPTICAL STATION 4 ! — I /1 `� OPTICIAN'S CASH DESK WHERE USED 44 DM2 TO MACY'S PHONE ROOM 102 .II r! , � ,, • L "J 45 DM3 TO MACY'S PHONE ROOM �/ I 1 I D r:� A17 r,, ' r •e LENSCRAFTERS' NETWORK 46 DM4 SPARE 5. EXISTING FIXTURE TO REMAIN. J _ CLC. HT.= la'-0" P Ix I I A� PRETEST j b (1)CATS(BY OTHERS)BETWEEN JACKS _ AD a� — - - Mime'• I ! /2/i/ 3 LCM A200 REV 0.0 103 D 1 — LOAD CENTER"A" OREGON 4.CLG. HT,= 10' 0' , r 'cl/71 , 1 OR 2, SEE PLANS. 1 WHEN THERE IS 1 1 I I I ' �C 8' SECOND OPTOS A SINGLE EXAM ROOM,2 WHEN I I A-6 I ; /yq E Ldp EXAM/REFRACTION THERE IS A 2ND EXAM ROOM. „� zEa N» oEHD-D1 DEHD-11 PRETEST 04e u ROOM - OPTOMETRIST NETWORK OSD • 103 iI (TMP) a , ! (EXPIRATION [SATE: 12/31/2016 ,� �, �- CLG. HT.= 10'-0" I j DATA INTERCONNECTION RISER A-1 :61' I i • Arzhitect/Engineer Job No.: CA`N\ EXAM I I I & I / SCALE; NONE ROOM -- :• g I - O ,_ , AD AD E- A-15 _ ` Nextore Store Design Revision No.: 104 — 'II' I1 zEaE w�� _ c rw'S 0 OEHD IST j [.I�ai -- E V KEY NOTES — ELECTRICAL POWER PLAN �' CLG. HT.= 10 a" 0.0 I 7 00 A� t 1. PROVIDE DIRECT CONNECTION IN WALL TO SERVE TANKLESS WATER HEATER. CONNECTION TO BE 25A,120V,SINGLE 10. ROUTE CONDUIT 6"ABOVE CEILING AND BUSH END. TYPICAL. C=/ I EXAM J (TMP) I I Nextore project PHASE. CIRCUIT AS INDICATED. COORDINATE LOCATION WITH PLUMBING CONTRACTOR. I I " I ROOM I Numberp 74095 U. VERIFY FIXTURE PLACEMENT DOES NOT OVERLAP LEASE LINE PRIOR TO FLOOR BOX ROUGH IN. COORDINATE WITH GC. ,rel 2. PROVIDE CORE DRILLING FOR POWER AND TELE/DATA TO SELECT TABLE.E.C.SHALL VERIFY ALL CORE DRILLING GC TO CONTACT PM IF ACTUAL FIELD CONDITIONS RESULT IN THE STORE FIXTURE OVERLAPPING THE LEASE LINE,PRIOR _ _ 104 I 'V LerisCrafters DeslgreType: REQUIREMENTS WITH THE LANDLORD PRIOR TO THE START OF WORK.PROVIDE DEVICES AND DEVICE QUANTITIES AS TO ROUGH IN, - JJ j 1 A-13 CLG, HT.= 10' 0'" GLOBAL SPECIFIED ON PLANS.E.C.SHALL COORDINATE INSTALLATION AND CONNECTION REQUIREMENTS WITH FURNITURE MANUFACTURER REPRESENTATIVE. 12. RECEPTACLE AND DATA OUTLET SERVES DIGITAL SIGNAGE. SEE ELEVATION ON ARCHITECTURAL SHEETS. VERIFY EXACT LOCATION OF ROUGH IN WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN. Ci) — I f t;, 4 A-13 ISSUED FOR: 3. PROVIDE 'FURNITURE" FLOOR BOX/POKE THRU AT THIS LOCATION-SEE SEE DETAIL IN DESIGN MANUAL.AND THE DATAI I. A Client Review ❑Li Approval INTERCONNECTION RISER. 13. PROVIDE NEC 517 REDUNDANT GROUNDING FOR RECEPTACLES AND SWITCHES/DIMMERS IN THIS ROOM. PROVIDE ' BONDING TO ALL METAL PARTS OF THE RACEWAY SYSTEM TO ENSURE THAT THE RACEWAY SYSTEM ACTS AS A I d I 0008 Permit QBid 4. PROVIDE JUNCTION BOX AND CIRCUIT FOR EYE EXAM SIGN. GROUNDING PATH,AND PROVIDE A SEPARATE GROUNDING CONDUCTOR. BOND THE CONDUCTOR AND THE RACEWAY 11',O - - ❑COB Permit-Re-Submit 0Construction TO THE RECEPTACLES TO CREATE A REDUNDANT PATH TO GROUND. USE HOSPITAL GRADE MC CABLE WHEN MC CABLE 5. PROVIDE JUNCTION BOX ABOVE CEILING FOR LENSCRAFTERS SIGN. IS THE WIRING METHOD USED. A-24 ! Title 6. VERIFY MOUNTING HEIGHTS OF OUTLETS WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN, 14. PROVIDE "RECESSED" FLOOR BOX/POKE THRU AT THIS LOCATION. SEE SEE DETAIL IN DESIGN MANUAL.AND THE DATA LIGHTING POWER INTERCONNECTION RISER. 7. CONNECT CIRCUIT TO MACY'S LIGHTING CONTROL SYSTEM. SEE SEE DETAIL IN DESIGN MANUAL, VERIFY SPECIFIC I I AND D LOQV V/ VOLTAGE REQUIREMENTS WITH MACY'S. 15. SEE DATA RISER DIAGRAM FOR ARRANGEMENT OF OUTLETS FOR THE DATA CABINET. / \ /� 8. PROVIDE RECESSED RECEPTACLE AT ELEVATION SHOWN ON ARCHITECTURAL SHEETS FOR POWER TO DIGITAL EYE CHART. 16. CASEWORK TO BE FIELD WIRED BY ELECTRICAL CONTRACTOR. SEE DETAIL IN DESIGN MANUAL. PLAN 9. ROUTE ONE 3/4' CONDUIT TO ABOVE CEILING FROM EMPTY 4X4 JUNCTION BOX WITH MUDRING INSTALLED AT HEIGHT EQUIVALENT TO ADJACENT POWER OUTLET. BUSH CONDUIT END AND PROVIDE PULL STRING. Date Sheet PLAN NORTH PLAN NORTH 12-2-16 Drawn By LIGHTING PLAN POWER AND LOW VOLTAGE PLAN E200 -1) STAFF 2 LCM A200 REV 0.0 (j) 2 Checked By SCALE: 1/4'=l'-0' SCALE: 1/4'=1'0' MR ELECTRICAL LOAD SUMMARY PANEL"A" N,Dc1DRE LOAD _ 1 ONE-UNE DIAGRAM NOTES 2 ELECTRIC ONE-LINE DIAGRAM - CONNECTED DEMAND DEMAND FACTOR LOAD DESCRIPTION (KW) FACTOR (KW) •4000 Luxottica Place,Masan,OH 45040 0+1(513)755-6000 LIGHTING 1.49 1.25 1.86 1. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL LANDLORD Q KEY NOTES; MACY'S ELECTRIC ROOM LENSCRAFTERS •6 Creamery eel,EastGranrv,CT 06026 11+1(516)393-2484 SHOW WINDOW RECEPTACLES 0.00 1 0.00 REQUIREMENTS PRIOR TO BIDDING&INCLUDE THE COST OF r0 SIGN 1.16 1.25 1.44 ALL ASSOCIATED LABOR, MATERIALS, &CHARGES IN HIS BID. 1. UTILIZE EXISTING PANEL FOR THE 60A FEED TO NEW LOAD CENTER 'A" STORE 48753 IN THE LENCRAFTER'S SPACE. VERIFY CURRENT LOAD ON EXISTING RECEPTACLES 3.90 100%<10K 3.90 2. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE AVAILABLE PANEL AND REPORT TO ENGINEER TO CONFIRM PANEL CAPACITY. Washington Square EQUIPMENT - 3.64 1 3.64 FAULT CURRENT WITH THE LANDLORD PRIOR TO BIDDING AND 9300SW Watington Square Rd. WATER HEATING 4.80 1.25 6.00 PROVIDE EQUIPMENT RATED ACCORDINGLY.SUBMIT FAULT r 1.25 OF CURRENT CALCULATIONS WITH SHOP DRAWING SUBMITTAL. (4)#6, (1)#8 GND IN 11/4"C. Tigard, OR 97223 HVAC 0.00 LARGEST 0.00 3. PROVIDE NAMEPLATES PER NAMEPLATE DETAIL. WHERE PERMITTED BY THE TOTALS: 14.99 TOTALS: 16.85 JURISDICTION AND Construction for. 4. COORDINATE SPACE WITH ALL OTHER TRADES TO MAINTAIN LANDLORD, MC CABLE CAN ALL CODE-REQUIRED CLEARANCES. BE USED FOR THIS INSTALLATION. ENGRAVED LAMACOID,5/32" VOLTAGE DROP CALCULATIONS 5. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL LETTERS, SECURE TO PANEL REQUIREMENTS. BOARD COVER WITH ADHESIVE VOLTAGE DROP TO BE LESS THAN 3% VD_ 2 x_ L x R x I TYPE FASTENER. 1000 6, THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH NEC V) MAeY's PANEL TO PANEL IN SPACE: ARTICLE 110.16 FOR LABELING OF PANELS FOR ARC FLASH HAZARD WARNING AS WELL AS FOLLOWING REQUIRED SAFETY Q O PRECAUTIONS WHEN SERVICING OR MAINTAINING ELECTRICAL O DISTANCE TO SPACE: 117 FT PLYWOOD BACKBORAD NEW EQUIPMENT. PANEL"A" i O d` (f) WIRE SIZE TO SPACE: 4#6(R=.4) 1-LCM-E300-REV 0.0 - - 120/208V C9 O �[ 3CdGOA R3 - >..... MCB L) 0 AMPS: 37.00 3 FIELD VERIFY ALL CONDITIONS W o 0 ,--1-r TIT -r-r-T- LUB2 < D t 30 VD= 3.46 VOLTS _ I I 1�_ 1J_ _1_L 'INN DESIGN DRAWINGS ARE SCHEMATIC.THE GENERAL CONTRACTOR ' ' _----_- ..1____i_ aJ n: 4NL2 R2 RI Q 0 Q I POS -A WALL TURNS LOAD CENTER CONSTRUCTION TO FIT SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT - QJ VD WALL TURNS PANEL IN STANDARD STUD WALL V VD%= - x 100 TO INSPECT EXISTING FIELD CONDITIONS.THIS CONTRACT SHALL 513 COORDINATE WITH GENERALti- L 208V INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD CONTRACTOR. Q3 MODIFICATIONS DUE TO EXISTING CONDITIONS. 0XF >, ca -g LDB-2 V E 3.46 08 X100 = 1.67 % THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT, I T T T T 11=, z ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS I I I I - AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL 1 S� > 2 COSTS TO MEET THE DESIGN INTENT.CLARIFICATIONS MADE BY THE 01 -. Z J ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL In AND SHALL BE IMPLEMENTED AT GENERAL CONTRACTORS COST. FLOOR NOTE: 1.) PANEL R2 IDENTIFIED AS USABLE PANEL,BUT ANY PANEL CAN BE USED. ¢[ f vi 2.)ALL PANELS ARE ON CONTROLLED RELAYS AND CAN BE ADJUSTED TO 24 HOUR BREAKERS. W BIDDING GENERAL CONTRACTORS SHALL HAVE A WORKING 3.)NEW 60/3 BREAKER SHALL PROVIDE POWER FOR NEW LC SPACE FOR 24X7 OPERATION. r6 KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL mmil 2 INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES,THE PLANS AND SPECIFICATIONS NOT WITHSTANDING.THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 3-LCM-E300-REV 0.0 2-LCM-E300-REV 0.0 Revisions: Panel Name: A Mark Date By A 12-2-16 STAFF Voltage: 120/208 Options: 120/208 or 277/480 Panel Type: Load center 9096 REVIEW SET Amps: 100A Buss amps can be standard,100A minimum AIC Rating: 10K MCB: MLO Main Circuit breaker amps A WATTS PER PHASE WATTS PER PHASE A _ A B C DESCRIPTION OF LOAD OCPD CKTIt CKT# OCPD DESCRIPTION OF LOAD A B C 175 AMBIENT LIGHTING AND CONTACTORS 20/1 1 2 20/1 SALES FLOOR SUPPLEMENTAL TRACK 833 A 483 CASEWORK LIGHTING AND SIGNS 20/1 3 4 20/1 CONVENIENCE OUTLETS 360 1440 SALES FLOOR TABLES 20/1 5 6 20/1 DOCTOR'S OFFICE WORK AREA 720 1560 RECEPT:EQ22 20/1 7 820/1 CONVENIENCE OUTLETS 360 A MIN SPARE 20/1 9 10 - 20/1 SPARE SPARE 20/1 11 12 20/1 SPARE 540 RECEPT: EQUIPMENT 20/1 13 14 20/1 DATA CABINET 360 360 RECEPT:EQUIPMENT 20/1 15 16 20/1 LF-13 UNSWITCHED POWER 100 Architect / Engineer of Record 360 RECEPT: EQUIPMENT 20/1 _ 17 18 20/1 DIGITAL SIGNAGE 1155 350 SALES FLOOR CASHDESK 20/1 19 20 20/1 180 SALES FLOOR NON-SWITCHED POWER 20/1 21 _ 22 20/1 WATER HEATER 2400 1560 SALES FLOOR NON-SWITCHED POWER 20/1 23 24 20/1 WATER HEATER 2400 2635 1023 3360 Totals Totals 1553 2860 4275 Voltage(360 for 120/208;830 for 277/480) 360 Load Characteristics: Total Load,Phase A: 4188 Amps per Phase A: 12 Total Load,Phase B: 3883 Amps per Phase B: 11 Total Load,Phase C: 7635 Amps per Phase C: 21 Seal Total Panel Load: 15706 Total Amps(assumes balanced): 39 it 401rIteliah ,-' i,("50 .iiiirl-r- l / /115 / •REGON /di4Y 8, 200 cc, h`AEL 9 EXPIRATION DATE: 12/31/2016 Architect/Engineer Job No.: Nextore Store Design Revision No.: REV 0.0 Nextore project 74095 Number lensCrafters Design Type: GLOBAL ISSUED FOR: R Client Review ❑IL Approval Q DOB Permit 0 Bid CI DOB Permit-Re-Submit 0 Construction Title DETAIL & RISER Date Sheet 12-2-16 Drawn By STAFF E300 Checked By MR