Loading...
Report (161) SYSTEM RECORD OF COMPLETION c2C`Cr1 This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data,or calculations as necessary to provide a complete record. Form Completion Date: Supplemental Pages Attached: 1. PROPERTY INFORMATION Name of property: Bridgeport Center Suite 300 Address: 7632 SW Durham Rd.#300 Tigard,OR 97224 Description of property: Vacant office space on 3rd floor. Name of property representative: Address: Phone: Fax: E-mail: 2. INSTALLATION,SERVICE,TESTING,AND MONITORING INFORMATION Installation contractor: Point Monitor Corp. Address: 5863 Lakeview Blvd.#100 Lake Oswego,OR 97035 Phone: 503-627-0100 Fax: E-mail: Service organization: Address: Phone: Fax: E-mail: Testing organization: Address: Phone: Fax: E-mail: Effective date for test and inspection contract: Monitoring organization: HSI Security Address: 3424 NE 5th Ave Portland,OR 97212 Phone: 503-287-4604 Fax: E-mail: Account number: 1151-5146 Phone line 1: Phone line 2: Means of transmission: Entity to which alarms are retransmitted: Phone: 3. DOCUMENTATION On-site location of the required record documents and site-specific software: By FACP, 1st Fl.Electrical Room 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: El New system ®Modification to existing system Permit number: FPS2018-00057 NFPA 72 edition: 2016 4.1 Control Unit G Xi51t r ^� Manufacturer: F -. Model number: 4.2 Software and Firmware Firmware revision number: 4.3 Alarm Verification ®This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds Copyright©2012 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 Control panel amps: Overcurrent protection: Type: Breaker Amps: Branch circuit disconnecting means location: Number: 5.1.2 Secondary Power Type of secondary power: Location,if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode(hours): 24 In alarm mode(minutes): 5 5.2 Control Unit ❑ This system does not have power extender panels ® Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line Device Power Initiating Device Notification Appliance B 1 Other(specify): 7. REMOTE ANNUNCIATORS Type Location 8. INITIATING DEVICES Addressable or Type Quantity Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations Smoke Detectors Duct Smoke Detectors Heat Detectors Gas Detectors Waterflow Switches Tamper Switches Copyright 0 2012 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible Visible 3 Wheelock SW Combination Audible and Visible 1 Wheelock HSW 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices HVAC Shutdown Fire/Smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip 11. INTERCONNECTED SYSTEMS ® This system does not have interconnected systems. ❑ Interconnected systems are listed on supplementary sheet 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: 1-. ++__ Printed name: � p� j�, ?V I/i e Date: el--/2--IS Organiz. : PO('d- 4.49,4,-1.0r r C ore. Title: , c a,t Phone: 7,,.7,--67.7-7-0/UD 12.2 System Operational Test This system as specifiedr' herein has tested according to all NFPA standards cited herein. Signed:/%�p, /1((1.° Printed name: t-ete�Yr.P�°k'ina, Date: el--J2 t g Organiz hon: !�I`04-Morto kr Title: I et✓tPhone: 907-624 f�JAp 12.3 Acceptance Test Date and time of acceptance test: el- 12,-/f' 6 OtePa,a- Installing contractor representative: j'aS<,NR�— Testing contractor representative: Property representative: AHJ representative: Copyright©2012 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution.