Plans (411) /1n5T2J1'— oo �6L1 CT ENGINEERING INC 180 Nickerson St. 1 316 ? 5 w i`I Ft9+( Throw, Suite 302 (jletf ,v� 97907 Seattle,WA 98109 (206)285-4512(V) (206)285-0618(F) asolomon@ctengineering.corn BULLETIN Date: September 10, 2018 Number: CT-53 Project#: 15238 Project Name: River Terrace SF Attached: CT-53.1 Subject: Lots 127, 128, 129, 131 (Plan 7)—Header for Garage Wall Electrical Panel Drawings Affected: Description/Action: This bulletin provides response to RFI's, design clarifications and/or variation requests for the `River Terrace SF' project located in Tigard, Oregon. Block out garage wall area and add header as shown per attached detail for installation of electrical panel. ��� PRC°�`?, a . IN4 140 4REG6N,N. 09/10/2018 CALL WITH ANY QUESTIONS Issued by: Arnold R. Solomon Date: Sept. 10, 2018 Distribution: Contact Information: Paul McColm Polygon Northwest Company Tom Dicianno Polygon Northwest Company Frank Sandoval Polygon Northwest Company Ken Wilde Polygon Northwest Company David Burnett Milbrandt Architects R:\15238 River Terrace SF\Bulletins\15238_2018.09.10_CT53_Lots 127, 128, 129, 131 (Plan 7)-Header for Garage Wall Electrical Panel.doc Structural Engineers 4 180 Nickerson St. CT ENGINEERING Suite 302 I N C. Seattle,WA Project: RIVER TERRACE (LOTS 127, 128, 129, 131 - PLAN 7) Date: 09/10/2018 98109 (206)285-4512 FAX Client: Page Number: CT-53. ' 1 (206(20G)285-0618 BEAM PER PLAN 4x12 BEAM /I/ t ELEC. PANEL 3'-0" MAX. (2)2x6 CRIPPLE SILL PLATE STUDS (1)2x6 CRIPPLE STUD GARAGE WALL ELEVATION NOT TO SCALE Structural Enaineers