Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (164)
Sac -a 3 401 Northwest Fire Suppression, inc. EQUIPMENT SUBMITTAL FOR CLEAN WATER SERVICES DURHAM O&M PHASE 2 FIRE ALARM /45Pe ,IkeerS\N 85th Avenue Tigard, OR 97224 7/19/2018 SYSTEM NFS-320 Fire Alarm System CONTENTS Manufacturer's Data Sheet 1800 NW 169th Place, Suite C600 • Beaverton, Oregon 97006 • 503-644-7720 • Fax 503-644-8289 www.nwfire.corn CCB#88629 Licensed • Bonded • Insured r Northwest Fire Suppression, Inc. pp EQUIPMENT LIST Model Number Description NFS-320 Addressable Fire Alarm Control Panel 1 NCM-F Network Control Module - Fiber FSP-851 Addressable Photoelectric Smoke Detector 2 FSP-851R Addressable Smoke Detector, Remote Reset Capable B210LP 6" Dia. Low Profile Detector Base 3 FST-851 Addressable 135 Deg. Fixed Temp Heat Detector DNRW Addressable Duct Det. Housing, Weatherproof 4 DST Duct Det. Sampling Tube 5 FRM-1 Addressable Relay Module 6 FDM-1 Addressable Dual Monitor Module 7 NBG-12LX Addressable Manual Pull Station 8 P2WL Multi-CD Horn/Strobe, Wall Mount, White PC2WL Multi-CD Horn/Strobe, Ceiling Mount, White 9 SCWL Multi-CD Strobe, Ceiling Mount, White 10 SWL Multi-CD Strobe, Wall Mount, White 11 SCWK Multi-CD Strobe, Ceiling Mount, White, Weatherproof 1800 NW 169th Place, Suite C600 • Beaverton, Oregon 97006 • 503-644-7720 • Fax 503-644-8289 www.nwfire.corn CCB#88629 Licensed • Bonded • Insured NFS-320(E) DN 7112tH•A-14 Intelligent Addressable 8 NOT' F' E R® Fire Alarm System by Honeywell Intelligent Fire Alarm Control Panels General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX®Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations,ONYX Series products meet virtually every application requirement. NFS-320 The NFS-320's modular design makes system planning easier. The panel can be configured with just a few devices for small building applications, or networked with many devices to pro- NOTIFIER tect a large campus or a high-rise office block. Simply add additional peripheral equipment to suit the application. For installations using NFS-320C, an optional ACM Series annunciator can be mounted in the same cabinet (up to 48 zones/points,order separately; see DN-60085). r The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet,saving the monthly cost of two dedicated business tele- phone lines. Although not required, the secondary telephone line may be retained providing backup communication over the NFS-320 public switched telephone line. NOTE:Unless called out with aversion-s version-specific`R" a • Alarm Verification selection per point,with tally. the end of the part number, "NFS-320"refers to models NFS-320, • Silence inhibit andve Alarm Sequence timer options. NFS-320R,NFS-320C,and NFS-320E. Silence inhibit Auto Silence options. • NAC coding functions: Features -March time. • Certified for seismic applications when used with the appro- –Temporal. priate seismic mounting kit. –California two-stage coding. • Approved for Marine applications when used with listed –Canadian two-stage. compatible equipment(see DN-60688). –Strobe synchronization. • One isolated intelligent Signaling Line Circuit(SLC)Style 4,6 • Field-programmable on panel or on PC, with VeriFire®Tools or 7. program check,compare,simulate. • Up to 159 detectors (any mix of ion, photo, thermal,or multi- • Full QWERTY keypad. sensor) and 159 modules (Addressable pull stations, nor- • Battery charger supports 18–200 AH batteries. mally open contact devices, two-wire smoke, notification, or • Non-alarm points for lower priority functions. relay).318 devices maximum. • Standard 80-character display. • Remote ACK/Signal Silence/System Reset/Drill via monitor • Network options: modules. • –High-speed network for up to 200 nodes (NFS2 3030, • Automatic time control functions,with holiday exceptions. NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC, Extensive, o transient protection. ONYXWorks,NFS-3030, NFS-640,and NCA). Powerful Boolean logic equations. –Standard network for up to 103 nodes (NFS2-3030, NFS2- FLASHSCAN®INTELLIGENT FEATURES 640, NFS-320(C), NFS-320SYS, NCA-2, DVC, ONYX- Works, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP- Poll up to 318 devices in less than two seconds. 300/400, AFP-1010, and AM2020). Up to 54 nodes when • Activate up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. DVC is used in network paging. 6.0 A power supply with four Class NB built-in Notification • Fully digital,high-precision protocol(U.S. Patent 5,539,389). • Appliance Circuits (NAC). Selectable System Sensor, • Manual sensitivity adjustment—nine levels. Wheelock,or Gentex strobe synchronization. • Built-in Alarm,Trouble, Security,and Supervisory relays. � Pre-alarm ONYX intelligent sensing—nine levels. • VeriFire®Tools online or offline programming utility. Upload/ • Sensitivity windowsc sensitivity adjustment. Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. –Ion–0.5 to 2.5%/foot obscuration. • Autoprogramming and Walk Test reports. –Photo–0.5 to 2.35%/foot obscuration. • Optional universal 318 point DACT. –Laser(VIEW®)–0.02 to 2.0%/foot obscuration. • 80-character remote annunciators(up to 32). –Acclimate®PIUSTM–0.5 to 4.0%/foot obscuration. • EIA-485 annunciators, including custom graphics. –IntelliQuad–1.0 to 4.0%/foot obscuration. • Printer interface(80-column and 40-column printers). • –Drift compensationiQuPLUS–1.0 to 4.0%/foot obscuration • History file with 800-event capacity in nonvolatile memory, (U.S. Patent 5,764,142). plus separate 200-event alarm-only file. DN-7112tH•08/09/2012—Page 1 of 6 , • • Degraded mode — in the unlikely event that the NFS-320's primary microprocessor fails, FlashScan detectors revert to FSC-851/NTELL/QUgp ADVANCED MULTI-CRITERIA DETECTOR degraded operation and can activate the control panel's NAC • circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. and Detects all four major elements of a fire (smoke, heat, CO, • Multi-detector algorithm involves nearby detectors in alarm • Au ofmatic)drift compensation of smoke sensor and CO cell. decision(U.S. Patent 5,627,515). • • Automatic detector sensitivity testing(NEPA-72 compliant . High nuisance-alarm immunity. • Maintenance alert(two levels). PLUS ) Six sensitivity levels. • Self optimizing pre-alarm. FCO-851 INTELL/QUADTM FSL-751 VIEW(VERY INTELLIGENT EARLY WARNING ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR ) • Detects all four major elements of a fire. SMOKE DETECTION TECHNOLOGY • Revolutionary spot laser design. • Separate signal for life-safety CO detection. • Advanced ONYX intelligent sensing algorithms differentiate TOemp-4(CO)dtone. able sounder base for Temp-3 (fire) or between smoke and non smoke signals (U.S. Patent 5,831,524). Automatic drift compensation of smoke sensor and CO cell. • Addressable operation pinpoints the fire location. • High nuisance-alarm immunity. • No moving parts to fail or filters to change. • Six sensitivity levels. • Early warning performance comparable to the best aspiration RELEASING FEATURES systems at a fraction of the lifetime cost. FAPT--851 ACCLIMATED PLUSTM • Ten independent hazards. LOW-PROFILE INTELLIGENT MULTI-SENSOR •• DelaSophisticated tiercross-zone(three options). • Detector automatically adjusts sensitivity levels without oper- ator Abort(four options). charge timers(adjustable). intervention or programming. heat. Sensitivity increases with • Low-pressure CO2 listed. • Microprocessor-based technology; combination photo and thermal technology. VOICE FEATURES • Integrates • FlashScan or CLIP("classic")mode compatible. • Integrates vtia th ser aoice l connection onri withSee DN-7004). Voice-5/502 • Low-temperature warning signal at 40°F ± 5°F (4.44°C ± Series(see DN-7003). 2.77°C) S HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 A POWER SUPPLY(6.0 A IN ALARM) • 120 VAC(NFS-320/NFS-320C);240 VAC(NFS-320E). • Displays battery current/voltage on panel(with display). Up to 32 Remote Displays SLC Intelligent Loop ---. .. = - - - BEV/CES - - El .... . .. FSC-851 — — — — — — — — — — — 3 f ' +it fit it ��� `te�QUBd" [S ;17411,==.7.- 174 11 Acclimate 7.- F L•-85 FnteliCuad VIEW® s f FDU✓t0 FSPi1 FhshBcar®photo NBQ•12LX FMM-1 FAM-1 XP6/10 LCD2-80 LCD2-80etcr 4. VO Modules EIA-485 IDC Relay Contact i - EIA-485 li 2048 annunciator/control points II IIII III IN F---71..!....-9!..1.!..1_1 ' mm mu Imm mm mm mm mmi mmi NFS-320 ACM-8R ACM/AEM-24AT Relay Control LED Annunciator LDM- Custom Graphics Optional 318 point UDACT Dual phone lines to Central Sample Station System men Options EIA-232 PRN Series Printer Page 2 of 6—DN-7112:H•08/09/2012 7172b1ok.wmi FlashScan, Exclusive own program, including control-by-event links to other points. World-Leading Detector Protocol This allows the program to be entered with independent per- At the heart of the NFS-320 is a set of detection devices and At the protocoleartf— FlashScanFS-320 a Patent 5,5 oFlsan per- point segments,installed)the NFS-320 simultaneously monitors can is an all-digital protocol that gives superior precision and other(already points for alarm conditions. noise immunity. VeriFire®Tools is an offline programming and test utility that can greatly reduce installation programming time,and increase con- highIn addition to providing quick identification of an active input fidence in the site-specific software. It is Windows®- In addition new protocolproviding canialso activatefi many output di u provides technologically advanced capabilities to a aid the in a fractione,this of the time ir s by competitive protocols. This high speed also allows the NFS-320 to have the largest device installer. The installercmay create the entire program for the Nen brin in the the sitett andf the office, testdit, store a backup tile, per loop capacity in the industry—318 points— ery then bring it to the download from a laptop into the and output device is sampled in less than two seconds.)Themicnput panel. thatcanbe coded to provide can diagnostic ors ormat ohave 'n,lor such as Placement of E device address during Walk Test. Equipmentin Chassis and Cabinet ONYX Intelligent Sensing Thedefollowing guidelines outline the NFS-320's flexible system Intelligent sensing is a set of software algorithms that provides Wiring: When designing the cabinet layout,consider separation the NFS-320 with industry-leading smoke detection capability, of Wiring: power-limited and non-power-limited wiring as discussed in These complex algorithms require many calculations on each reading of each detector, and are made possible by the high- It is critical hat Insll tallation g holes of the NFS-320 are d speed microcomputer used by the NFS-320. with a screw or standoff to ensure continuity of Earth Ground. Drift Compensation and Smoothing: allows the detector to retain its original ability to detect actual unit requires a Network Control Module or Drift compensation Networking: If networking two or more control panels, each Net- smoke, and resist false alarms, even as dirt accumulates. It redukeand is a requirements y allowingsdrtthe system to High-Speed e work Control Module (HS-NCMon can support two nodes;page 4). These sasee automatically perform the periodic sensitivity measurements "NetworkingOptions" on n required by NFPA 72. Smoothingfilters are also provided by installedionin any boardsdon board positionn (see manual), and peel software to remove transient noise signals, such as those tional option can be mounted in front of them. caused by electrical interference. Maintenance Warnings: When the drift compensation KDNI-R2 Controls and Indicators formed for a detector reaches a certain level,the performanceof9 am Ke the detector may be compromised, and special warnings are per- Program Indicators: Power; Fire Alarm; Pre-Alar Keypad:QWERTY type(keyboard layout). given. There are three warning levels: (1) Low Chamber value; Supervisory; System Trouble; Signals Silenced Dis- (2) Maintenance Alert, indicative of dust accumulation that is abled;Control Active;Abort; Pre-Discharge;Discharge.m Security; near but below the allowed limit;(3)Maintenance Urgent, indica- Points tive of dust accumulation above the allowed limit. Display; Sensitivity Adjust: Nine sensitivity levels are provided for Keypad SwitchSy Controls: Acknowledge/Scroll Display; Signal edetection. These levels can be set manually, or can Silence;Drill;System Reset;Lamp Test. change automatically between day and night. Nine levels of pre- LCD Display: 80 characters (2 x 40) with long-life LED back- alarm sensitivity can also be selected, based on predetermined light. levels of alarm. Pre-alarm operation can be latching or self_ Product Line Information restoring,and can be used to activate special control functions. •Self-Optimizing Pre-Alarm:Each detector may be set for"Self- "Networking kingon Guidelines"on page page 3 Optimizing" pre-alarm. In this special mode, the detector "Networking Options"on 4 "learns" its normal environment, measuring theepeak analog readings over a long period of time, and setting the pre-alarm "Auxiliary PeroSupplies and Batteries"on page 4 level just above these normal peaks. • "Audio Options" P g • "Compatible Devices, EIA-232 Ports"on page 4 Cooperating Multi-Detector Sensing: A patented feature of • "Compatible Devices, EIA 485 Ports"on ONYX intelligent sensing is the ability of a smoke sensor to con- • "Compatible Intelligent Devices"on page 4 sider readings from nearby sensors in making alarm or pre- page 4 alarm eadings Without tatensol in n in the abilityrto resist false alarms,it allows a sensor to increase its sensitivity to "Enclosures, Chassis,and Dress Plates"on page 5 actual smoke by "Other Options"on page 5 a factor of almost two to one. CONFIGURATION GUIDELINES The NFS-320 system ships assembled,. description and some Field Programming Options options follow.Autoprogram. This timesaving feature is a special software follow. See "Enclosures, Chassis, and Dress Plates"on page 5 for information about mounting routine. The FACP "learns" what devices are physically con- nested and automatically loads them in the program with default NOTE:Stand-a/one and network systems require/s. a main displayvalues for all parameters. Requiring less than one minute to run, Pay On network systems (two or more networked fire pane/ On stand-alone systems, the panel's keypad provides the required this routine allows the user to have almost immediate fire protec- did l at least one NCA-2, NCS, or ONYX Works annunciation a portion of the detectors nodes), required. tion in a new installation, even if only are installed. device is NFS-320: The standard, factory-assembled NFS-320 system Keypad Program Edit (with KDM-R2) The NFS-320, like all includes the following components: one control panel mounted NOTIFIER intelligent panels, has the exclusive feature of pro gram creation and editing capability from the front panel keypad, tory interconnect cables, and document kit); includes integral on chassis(120 V operation—ships with grounding cable,bat- - continuing to provide fire protection. The architecture of power supply mounted to the main circuit board; one the NFS-320 software is such that each point entry carries its display KDM-R2 keypad/display;and one cabinet for surface or primary DN-7112tH•08/09/2012—Page 3 of a semi-flush mounting. Purchase batteries separately. One or two COMPATIBLE DEVICES,EIA-485 PORTS option boards may be mounted inside the NFS-320 cabinet,• ACM-24AT:ONYX Series ACS annunciator-up to 96 points of additional option boards can be used in remote cabinets. NFS-320R:Same as NFS-320 above,but in red enclosure. annunciation with Alarm or Active LED,Trouble LED,and switch per NFS-320C: Based on NFS-320 above. NFS-320C supports ered-up switch selection)byEpoint to be red,d,green,or yelprogrammedlllow;the installation of an optional ACM-series annunciator in the same Trouble LED is always yellow. See DN-6862. cabinet. UL-and ULC listed. AEM-24AT: Same LED and switch capabilities as ACM-24AT, NFS-320CR: Same as NFS-320C but in a red enclosure. expands the ACM-24AT to 48,72,or 96 points. See DN-6862. NOTE:For additional information on NFS-320C,see DN-60085. ACM-48A: ONYX Series ACS annunciator-up to 96 points of annunciation with Alarm or Active LED per circuit. Active/Alarm NFS-320E:Same as NFS-320 above,but with 240 V operation. LEDs can be programmed (by powered-up switch selection) in TR-320:Trim ring for the NFS-320 cabinet. groups of 24 to be red,green,or yellow. Expandable to 96 points NETWORKING OPTIONS with one AEM-48A. See DN 6862. NCM-W, NCM-F: Standard Network Communications Modules. AEM-48A: Same LED capabilities as ACM-48A, expands the Wire and multi-mode fiber versions available.See DN-6861. ACM 48A to 96 points. See DN-6862. High-speed network ACM-8R: Remote Relay Module with eight Form-C contacts. HS-NCM-W/MF/SF/WMF/WSF/MFSF communications modules. Wire, single-mode fiber, multi-mode Can . See DN- up to 6,000 ft. (1828.8 m) from panel on four wires. fiber, and media conversion models are available. See DN DN 3558. 60454. LCD-80: ACS mode. 80-character, backlit LCD display. Mounts RPT-W,RPT-F, RPT-WF: Standard-network repeater board with up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See wire connection (RPT-W), fiber connection (RPT-F), or allowing LCD-80%80TM(DN-3198). a change in media type between wire and fiber(RPT WF). Not FDU-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per used with high-speed networks. See DN 6971. ONYXWorks: UL-listed graphics PC workstation, software, and FACP See DN-6820. LCD2-80: Terminal mode. 80 character, backlit LCD display. computer hardware. See DN-7048 for specific part numbers. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per NFN-GW-EM-3: NFN Gateway,embedded. FAC P. See DN-60548. AUXILIARY POWER SUPPLIES AND BATTERIES LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-R32; ACPS-610: 6.0 A or 10 A addressable charging power supply. remote custom driver modules. See DN-0551. See DN-60244. SCS: Smoke control stations SCS-8, SCE-8, with lamp drivers APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes SCS 8L, SCE-8L; eight (expandable to 16) circuits. See DN- of power for peripheral devices.Includes battery input and trans- 4818. fer relay,and overcurrent protection. Mounts on two of four posi- TM-4: Transmitter Module. Includes three reverse-polarity cir- tions on a CHS-4L or CHS-4 chassis. See DN-5952. cuits and one municipal box circuit; mount on NFS-320 chassis FCPS-24S6/S8: Remote 6 A and 8 A power supplies with bat- or remotely. See DN 6860. tery charger. See DN-6927, UDACT: Universal Digital Alarm Communicator Transmitter,636 BAT Series: Batteries. NFS-320 uses two 12 volt, 18 to 200 AH channel. See DN 4867. batteries. See DN-6933. UDACT-2: Universal Digital Alarm Communicator Transmitter, AUDIO OPTIONS 636 channel. See DN-60686. 25 watt, 25 VRMS, emergency Voice Evacuation UZC-256: Programmable Universal Zone Coder provides posi- NFV-25/50:Control Panel(VECP)with integral commercial microphone,dig- controlled,oe nllefield-programmableng successive fromoe coding. omro iblee PCs ital message generator, and single-/dualchannel Class A or nal programming IBMs compatible Pee Class B speaker circuits. See DN-7004. (requires optional programming kit). Mounts in BB-UZC. See NFV-25/50DA: Single channel, 25 Watt, 25 VRMS, emergency DN 3404. voice evacuation panel. See DN-60048. COMPATIBLE INTELLIGENT DEVICES NFV 25/50DAZS:Single channel,25 Watt,25 Vrms,emergency BEAMHK: Heating kit for transmitter/receiver unit of voice evacuation panel. Can be automatically activated via the FSB-200(S)below. See DN-6985. Zone System serial communication link from the NFV-25/50ZS. BEAMHRK: Heating kit for use with the reflector of FSB-200(5) See DN-60049. below. See DN-6985. NFV-25/50ZS: 25 watt, 25 Vrms, emergency Voice Evacuation BEAMLRK: Long-range accessory kit, FSB-200(5) below. See Control Panel(VECP)with integral commercial microphone,dig- DN-6985. ital message generator, zone splitter module (ACC-ZSM), zone BEAMMRK:Multi-mount kit,FSB 200(S)below. See DN-6985. page module with keypad(ACC-ZPMK). See DN-7003 NFV-25/50ZST:25 watt,25 Vrms, emergency Voice Evacuation BEAMSMK: Surface mount kit, FSB 200(S) below. See DN- Control Panel(VECP)with integral commercial microphone,dig- ital 6985. message generator, zone splitter module (ACC-ZSM), zone FSB-200:Intelligent beam smoke detector. See DN-6985. page module with keypad(ACC-ZPMK). See DN-60337. FSB-200S: Intelligent beam smoke detector with integral sensi- COMPATIBLE DEVICES,EIA-232 PORTS tivity test. See DN-6985 FSC-851:FlashScan IntelliQuad Advanced Multi-Criteria Detec- PRN-6:80 column printer. See DN 6956. tor. See DN-60412. VS4095/5: Printer, 40 column, 24 V. Mounted in external back- box. See DN-3260. FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Crite DPI-232: Direct Panel Interface, specialized modem for extend- ria Fire/CO Detector. See DN-60689. DN- ing serial data links to remotely located FACPs and/or peripher- FSI-851: Low-profile FlashScan ionization detector. See als;mount on NFS-320 chassis. See DN-6870. 6934. KINIONOMMISEMIVENTIONSOISIO Page 4 of 6-DN-7112:H•08/09/2012 FSP-851: Low-profile FlashScan photoelectric detector. See SEISKIT 320/B26: Seismic mounting kit. Required for DN-6935. seismic- FSP-851T: Low-profile FlashScan photoelectric detector with certified applications with NFS-320 and BB-26. Includes battery 135°F(57°C)thermal. See DN-6935. bracket for two 26 AH batteries. FSP-851R: Remote test capable photoelectric detector for use SEISKIb--BB2e5 f Seismictt6 AH batteries,for the BB-25. Includes with DNR(W)duct detector housings. Sce DN 6935. battery FST 851: FlashScan thermal detector 135°F SEISKIT LBB: Seismic kit for the NFS LBB. Includes battery DN-6936. (57°C). See bracket for two 55 AH batteries. FST-851R: FlashScan thermal detector 135°F(57°C)with rate- SEISKIT PS/2/4: Seismic mounting kit for the FCPS-2456/58 of-rise. See DN-6936. and CAB-PS1. Includes battery bracket for two 7 AH or 12 AH batterFST-851H: OTHER851H: FlashScan 190°F (88°C) high-temperature thermal detector. See DN-6936. OPTIONS 411:Slave Digital Alarm Communicator. See DN-6619. FAPT ti-sensor mu 851: FlashScan Acclimate Plus low-profile multi-sensor See DN-6937. 411 UDAC: Digital Alarm Communicator. See DN-6746. FSL-751:FlashScan VIEW laser photo detector. See DN-6886. IPDACT 2/2 , Internet Monitoring Module: Con DNR: InnovairFlex low-flow non-relay duct detector housin nects to primaryUDandIPDACT secondary DACT telephone output ports (order FSP-851Ree D separately). Replaces FSD-751 PL/FSD- for Internet communications over customer-provided ethernet (order . S4ep. connection. Requires compatible Teldat VisorALARM Central Station Receiver.Can use DHCP or static IP. See DN-60408. DNRW: Same as above with NEMA-4 rating, watertight. See DN-60429. IPSPLT: Y-adaptor option allow connection of both panel dialer B224RB:Low-profile relay base. See DN-60054. outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes 1PBRKT B224B1: Isolator base for low-profile detectors. See DN-60054. mounting bracket; Red. For Black order IPENC-B. B210LP: Low-profile base. Standard U.S. style. Replaces IPGSM-DP: Internet and Digital Cellular Fire Alarm Communi- B710LP. See DN-60054. B501:European-style,4"(10.16 cm)base. See DN-60054, cator. Providesselectable w thhcellularconfigurabpaths: cellular only, IP to the primary B200S: Intelligent only,or IP producing a variety oftonepatterns including ng ANSI Temporal ofunder base, capable and secondary ports of a DACT. Replaces IPGSM-COM. See Compatible with sychronization protocol. See DN-60054. DH-60695. NFS-320-RB: Replacement CPU. NOTE: Keypad must be : Sounder base, Temporal 3 or Continuous tone. See •removed before shipping old unit out for repair. DN-60054. FMM-1: FlashScan monitor module. See DN-6720. • NFS-320 RBE: Replacement CPU, Export. DN-600 • NFS-320-RBC-FR: Replacement CPU, Canadian French. FDM-1: FlashScan dual monitor module. See DN-6720. FZM-1: FlashScan two-wire detector monitor module. See DN- • NFS-320 RB-PO: Replacement CPU, Portuguese. 6720. • NFS-320-RB-POE: Replacement CPU, Export, Portu- FMM-101:FlashScan miniature monitor module. See DN-6720. • guese. FCM-1:FlashScan NAC control module. See DN-6724. NFS-320 RB SP: Replacement CPU,Spanish. FCM-I-REL: FlashScan releasing control module. See DN- • NFS-320-RB-SPE: Replacement CPU, Export, Spanish. 60390. NOTE:For other options including compatibility with retrofit equip- ment,refer to the panel's installation manual,the SLC manual,and FRM-1:FlashScan relay module. See DN-6724. the Device Compatibility Document. FDRM-1: FlashScan dual monitor/dual relay module. See DN- 60709. NBG-12LX:Manual pull station,addressable. See DN-6726. ISO-X: Isolator module. See DN-2243, XP6-C: FlashScan six-circuit supervised control module. See DN-6924. XP6-MA: FlashScan six-zone interface module;connects intelli- gent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan six-relay(Form-C) control module. See DN- 6926. XP1O-M: FlashScan ten-input monitor module. See DN-6923. ENCLOSURES, CHASSIS,AND DRESS PLATES CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. For a full list of required and optional equipment,see DN-60688. BB-UZC: Backbox for housing the UZC-256. Required for NFS- 320 applications. Black. For red,order BB-UZC-R. NFS-LBB: Battery Box (required for batteries larger than 26 AH). NFS-LBBB:Same as above,but red. DN-7112:H•08/09/2012-Page 5 of 6 SYSTEM SPECIFICATIONS ANIIIMIonsmillINIMISSIMMIROMINMOMAIMMISNIMIUMIMIIMMIMMIMmeMOMMVIMMSSIMISOMMOYJMOIR System Capacity Agency Listings and Approvals • Intelligent Signaling Line Circuits 1 The listings and approvals below apply to the basic NFS-320 • Intelligent detectors 159 control panel. In some cases,certain modules may not be listed • Addressable monitor/control modules 159 by certain approval agencies, or listing may be in process. Con- • Programmable internal hardware and output circuits 4 sult factory for latest listing status. • Programmable software zones 99 • UL Listed:S635. Special programming zones 14 • ULC Listed:S635(NFS-320C only,excludes IPDACT). •• LCD annunciators per NFS-320/-320E •• FM Approved. ACS annunciators 32 • • CSFM: 7165-0028:0243. per NFS-320/-320E 32 addresses x 64 points • MEA: 128-07-E. • FDNY:COA#6085. Specifications • City of Chicago. • Primary input power When used with the CAB-BM marine system,a —NFS 320: 120 VAC,50/60 Hz,5.0 A. ropriate seis- mic bracket, and marine approved devices, these ONYX fire —NFS 320E:220/240 VAC,50/60 Hz,2.5 A. alarm control panels are approved by the following agencies: • Total output 24 V power:6.0 A in alarm. • US Coast Guard: 161.002/50/0(Standard 46 CFR). NOTE: The power supply has a total of 6.0 A of available power. • Lloyd's Register: 11/600013(ENV 3 Cate or This is shared by all internal circuits. g y) • American Bureau of Shipping. • Standard notification circuits(4): 1.5 A each. NOTE: For additional information on UL- and ULC-listed model • Resettable regulated 24V power: 1.25 A. NFS-3200, see DN-60085. For information on NFS-320SYS, see • Two non-resettable regulated 24V power outputs: DN-60637. For information on the CAB-BM marine system, see —1.25 A. DN-60688. —0.50 A. Standards • Non-resettable 5V power:0.15 A. The NFS-320 complies wi L • Battery charger range: 18 AH—200 AH. Use separate cabi- NFPA 72, IBC,and CBC Fire Alaerm Systemsfollowing requirements and net for batteries over 26 AH. • Float rate:27.6 V. • UL 864(Fire). • UL 1076(Burglary). • LOCAL (Automatic, Manual, Waterflow and Sprinkler Super- Cabinet Specifications visory). NFS 320 cabinet dimensions: •Backbox: 18.12 in. (46.025 cm) width; 18.12 in. (46.025 cm) TM-4). M-4)AUXILIARY (Automatic, Manual and Waterflow) (requires • TM-4. height;5.81 in. (14.76 cm)depth. • REMOTE STATION (Automatic, Manual, Waterflow and • Door: 18.187 in. (46.195 cm) width; 18.40 in. (46.736 cm) Sprinkler Supervisory)(requires TM-4). height;0.75 in. (1.905 cm)depth. • PROPRIETARY(Automatic,Manual,Waterflow and Sprinkler • Trim ring: Molding width is 0.905 in. (2.299 cm). Supervisory). Not applicable for FM. • Shipping weight(without batteries):36.15 lb. (16.4 kg). • CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory)(requires UDACT). Temperature and Humidity Ranges • EMERGENCY VOICE/ALARM. This system meets NFPA requirements for operation at 0— OTPSDN (Other Technologies, Packet switched Data Net 49°C/32—120°F and at a relative humidity 93%±2%RH • work). (noncondensing)at 32°C±2°C(90°F±3°F). However,the IBC 2000,IBC 2003,IBC 2006,IBC2009(Seismic). useful life of the system's standby batteries and the electronic • CBC 2007(Seismic). components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore,it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15—27°C/60—80°F NOTI•FIRE•NETTM IntelliGuadiM,and ONYXWorksTM are trademarks;and Acclimate® PIusTM, FlashScan®, NOTIFIER®, ONYX®, VeriFire®, and VIEW®are registered trademarks of Honeywell International Inc.Microsoft® and Windows®are registered trademarks of Microsoft Corporation.IBM®is a registered trademark of IBM Corporation. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. :-:•:.:.:•:..m......: C E RT F 1 E O We cannot cover all specific applications or anticipate all requirements. DINNEEIIN;aMANUFACTRRINB All specifications are subject to change without notice. QUALITY SYSTEMS '�� For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. Made in the U.S.A. www.notifier.com Page 6 of 6—DN-7112:H•08/09/2012 DN-6935:D•H-202 FSP-851 (A) Series Intelligent Plug-In Photoelectric N®T' Fl E N Smoke Detectors with FlashScan® by Honeywell Intelligent/Addressable Devices General Notifier FSP-851(A) Series intelligent plug-in smoke detectors with integral communication provide features that surpass con- ventional detectors. Detector sensitivity can be programmed in let the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance i when chamber contamination reaches an unacceptable level. 1 / The FSP-851(A) photoelectric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP- 851T(A).The FSP-851 R(A)is a remote test capable detector for use with DNR(A)/DNRW duct detector housings. FSP-851(A) a series detectors are compatible with Notifier Onyx and CLIP FSP-851(A) in B210LP(A) Base series Fire Alarm Control Panels(FACPs). FlashScan®(U.S. Patent 5,539,389)is a communication proto- col developed by Notifier that greatly increases the speed of —B200SR(A):6.875"(17.46 cm)diameter. communication between analog intelligent devices. Intelligent —B224RB(A):6.2"(15.748 cm)diameter. devices communicate in a grouped fashion. If one of the devices —B224BI(A):6.2"(15.748 cm)diameter. in the group has new information, the panel's CPU stops the Shipping Weight:5.2oz.(147g). group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. ( 2°Fato 120°F). FSP-85rature range: FSP 38 38°C (,(32°F to 49°C (32 F to FSP-851T(A), 0°C to 38°C (32°F to 100°F). Features Low temperature signal for FSP-851T(A) at 45°F +/- 10°F (7.22°C+/-5.54°C). FSP-851 R(A)installed in a DNR(A)/DNRW, • Sleek, low-profile design. -20°C to 70°C(-4°F to 158°F). • Addressable analog communication. UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/ • Stable communication technique with noise immunity. min.),suitable for installation in ducts. • Low standby current. Relative Humidity: 10%-93%noncondensing. • Two wire SLC connection. Thermal Ratings:Fixed-temperature setpoint 135°F(57°C). • Compatible with FlashScan®and CLIP protocol systems. DETECTOR SPACING AND APPLICATIONS • Rotary,decimal addressing(1-99 on CLIP systems, 1-159 on Notifier recommends spacing detectors in compliance with FlashScan systems). NFPA 72. In low airflow applications with smooth ceiling, space • Optional remote,single-gang LED accessory. detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) • Dual LED design provides 360°viewing angle. and higher. For specific information regarding detector spacing, • Visible bi-color LEDs blink green every time the detector is placement, and special applications refer to NFPA 72. System addressed, and illuminate steady red on alarm (FlashScan Smoke Detector Application Guide, document A05-1003, is systems only). available at systemsensor.com • Remote test feature from the panel. ELECTRICAL SPECIFICATIONS • Walk test with address display(an address on 121 will blink Voltage Range: 15-32 volts DC peak. the detector LED: 12-[pause]-1(FlashScan systems only). • Built-in functional test switch activated by external magnet. Standby Current(max.avg.): 300pA @ 24VDC (one commu- • Built-in tamper-resistant feature. nication every five seconds with LED enabled). • Sealed against back pressure. LED Current(max.):6.5mA @ 24 VDC("ON"). • Constructed of off-white fire-resistant plastic, designed to commercial standards,and offers an attractive appearance. Installation • 94-5V plastic flammability rating. FSP-851(A) plug-in detectors use a separate base to simplify • SEMS screws for wiring of the separate base. installation, service, and maintenance. A special tool allows • Optional relay, isolator,and sounder bases. maintenance personnel to plug in and remove detectors without using a ladder. Specifications Mount base(all base types)on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction Sensitivity:0.5%to 2.35%per foot obscuration boxes,see DN-60054. Size:2.1"(5.3 cm)high;base determines diameter. NOTE: 1) Because of inherent supervision provided by the SLC —6210LP(A):6.1"(15.5 cm)diameter. loop, end-of-line resistors are not rec)uired. Wiring `T-taps" or —6501(A):4.1"(10.4 cm)diameter. branches are permitted for Style 4 (Class `B') wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation —B200S(A):6.875"(17.46 cm)diameter. DN-6935:D•12/08/2011—Page 1 of 2 sheet 156-1380 for device limitations between isolator modules ACCESSORIES and isolator bases. F110: Retrofit flange to convert B210LP(A) to match the Agency Listings and Approvals 6710LP(A) profile, or to convert older high-profile bases to low- profile. These listings and approvals apply to the modules specified in F110BP: Bulk pack of F110;package contains 15. this document. In some cases, certain modules or applications F210:Replacement flange for B210LP(A)base. may not be listed by certain approval agencies,or listing may be in process. Consult factory for latest listing status. RA100Z(A): Remote LED annunciator.3—32 VDC.Mounts to a • UL Listed: S1115. U.S. single-gang electrical box. For use with B501(A) and • ULC Listed:S1115(FSP-851A, FSP-851RA, FSP-851TA). B210LP(A)bases only. • MEA Listed:225-02-E. SMB600: Surface mounting kit • FM Approved. M02-04-00:Test magnet. CSFM:7272-0028:0206. M02-09-00:Test magnet with telescoping handle. •• Maryland State Fire Marshal: Permit#2122. XR2B: Detector removal tool.Allows installation and/or removal • BSMI:01313066760036. of detector heads from bases in high ceiling applications. • CCCF: Certif.#2004081801000017(FSP-851T) XP-4:Extension pole for XR2B.Comes in three 5-foot(1.524 m) Certif.#2004081801000016(FSP-851). sections. • U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 T55-127-010. Detector removal tool without pole. (NFS2-640/NFS-320/NFS-320C,excluding B210LP(A)). BCK-200B:Black detector covers for use with FSP-851(A)only; • Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- box of 10. 320C,excluding B210LP(A)). WCK-200B: White detector covers for use with FSP-851(A) Product Line Information only;box of 10. NOTE:A"suffix indicates ULC Listed model. FSP-851: Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP-851A:Same as FSP-851 but with ULC listing. FSP-851T: Same as FSP-851 but includes a built-in 135°F (57°C)fixed-temperature thermal device. FSP-851TA:Same as FSP-851T but with ULC listing. FSP-851 R: Low-profile intelligent photoelectric sensor, remote test capable.For use with DNRA/DNRW. FSP-851 RA: Same as FSP-851 R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE:"A"suffix indicates ULC Listed model. NOTE:For details on intelligent bases,see DN-60054. B210LP(A):Standard U.S.flanged low-profile mounting base. B210LPBP:Bulk pack of B210LP;package contains 10. B501(A):Standard European flangeless mounting base. B501 BP:Bulk pack of B501;package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tempo- ral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces 8501 BH series bases in retrofit applications. B224R6(A): Plug-in System Sensor relay base. Screw termi- nals: @ 30 VDC res stive;0.3 A 2@ Relay110 VDC induut ing:2.0 c ve,; 1.0 AA @ 30 VDC inductive. B224BI(A): Plug-in System Sensor isolator detector base. -Notifier® and FlashScan® are registered trademarks of Honeywell Maximum 25 devices between isolator bases. International Inc. ©2011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. IIIIIINimmumammumminamMittiMpernMsommattaliblitMuMINAimumummunimmanimaimmtinikNattalll ISO9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. E R T F E O We cannot cover all specific applications or anticipate all requirements. MENEEIIN611 MANIMMIINI QUALITY SYSTEMS All specifications are subject to change without notice. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. Made in the U.S.A. www.notifier.com Page 2 of 2—DN-69350•12/08/2011 FST-851 (A) Series DN-6936:B•H-211 Intelligent Thermal (Heat) Detectors N OT' F ' E R® with FlashScan® by Honeywell Intelligent/Addressable Devices General Notifier FST-851(A)Series intelligent plug-in thermal detectors with integral communication has features that surpass conven- tional detectors. Point ID capability allows each detector's NI. , address to be set with rotary, decimal address switches, pro- viding exact detector locations. FST-851(A) Series thermal detectors use an innovative thermistor sensing circuit to pro- duce 135°F/57°C fixed-temperature (FST-851/A) and rate-of- rise thermal detection (FST-851 R/A) in a low-profile package. �, FST-851 H(A) provides fixed high-temperature detection at ',Na 190°F/88°C. These thermal detectors provide effective, intelli- gent property protection in a variety of applications. FST 851(A)Series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels(FACPs). a FlashScan®(U.S. Patent 5,539,389) is a communication pro- FST-851(A)In B210LP(A)Base tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices • 94-5V plastic flammability rating. communicate in a grouped fashion. If one of the devices within • Remote LED output connection to optional RA100Z(A) the group has new information, the panel's CPU stops the remote LED annunciator. group poll and concentrates on single points. The net effect is • response speed greater than five times that of earlier designs. Optional sounder,relay, and isolator bases. • Optional flanced surface mounting kit. Features • Sleek, low-profile,stylish design. Specifications • State-of-the-art thermistor technology for fast response. Size:2.1 (5.3 cm)high;base determines diameter. • Rate-of-rise model(FST-851 R/A), 15°F(8.3°C)per minute. —B210LP(A):6.1"(15.5 cm)diameter. • Factory preset fixed temperature at 135°F(57°C);high-tern- —B501(A):4.1"(10.4 cm)diameter. perature model fixed at 190°F(88°C). —B200S(A):6.875"(17.46 cm)diameter. • Addressable by device. —B200SR(A):6.875"(17.46 cm)diameter. • Compatible with FlashScan®and CLIP protocol systems. —B224RB(A):6.2" (15.748 cm)diameter. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 —B224BI(A):6.2"(15.748 cm)diameter. on FlashScan systems). Shipping weight:4.8 oz. (137 g). • Two-wire SLC connection. Operatintemperature range: FST-851(A) Series, FST- • Visible LEDs"blink"every time the unit is addressed. 851R(A):g20°C to 38°C(-4°F to 100°F);FST-8511 H(A) —20°C • 360°-field viewing angle of the visual alarm indicators (two to 66°C(-4°F to 150°F). bi-color LEDs). LEDs blink green in Normal condition and Detector spacing: UL approved for 50 ft. (15.24 m)center to turn on steady red in Alarm. center. FM approved for 25 x 25 ft. (7.62 x 7.62 m)spacing. • Integral communications and built-in device-type identifica- Relative humidity: 10%—93%noncondensing. tion. • Remote test feature from the panel. Thermal ratings: fixed-temperature setpoint 135°F (57°C), • Built-in functional test switch activated by external magnet. rate-of-rise detection 15°F (8.3°C) per minute, high tempera- Walk test with address display(an address of 121 will blink ture heat 190°F(88°C). • the detector LED 12-(pause)-1). ELECTRICAL SPECIFICATIONS • Low standby current. Voltage range: 15-32 volts DC peak. • Backward-compatible. Standby current(max. avg.): N A @ 24• Built-in tamper-resistant feature. com- munication every 5 seconds wit300ED enabled).VDC (one • Designed for direct-surface or electrical-box mounting. LED current(max.):6.5 mA @ 24 VDC("ON"). • Sealed against back pressure. • Plugs into separate base for ease of installation and main Applications tenance. Separate base allows interchange of photoelec- Use thermal detectors for protection of property. For further tric, ionization and thermal sensors. information, go to systemsensor.com for manual 156-407-00, • SEMS screws for wiring of the separate base. Applications Manual for System Smoke Detectors, which pro- • Constructed of off-white fire-resistant plastic, designed to vides detailed information on detector spacing, placement, commercial standards,and offers an attractive appearance. zoning,wiring, and special applications. DN-6936:B•12/07/2011—Page 1 of 2 Installation with ANSI Temporal 3, ANSI Temporal 4, continuous tone, The FST Series plug-in intelligent thermal detectors use a sep- marching tone,and custom tone. arate base to simplify installation, service, and maintenance. B200SR(A): Intelligent sounder base capable of producing Installation instructions are shipped with each detector.A spe- sound output with ANSI Temporal 3 or continuous tone. cial tool allows maintenance personnel to plug in and remove Replaces B501 BH series bases in retrofit applications. detectors without using a ladder B224RB(A): Intelligent relay base. Screw terminals: up to 14 Mount base (all base types) on an electrical backbox which is AWG (2.0 mm2). Relay type: Form-C. Rating:2.0 A @ 30 VDC at least 1.5"(3.81 cm)deep. For a chart of compatible junction resistive;0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC induc- boxes,see DN-60054. tive. NOTE: 1) Because of the inherent supervision provided by the B224BI(A): Intelligent isolator base. Isolates SLC from loop SLC loop, end-of-line resistors are not required. Wiring`T-taps"or shorts. Maximum: 25 devices between isolator bases; see branches are permitted for Style 4 (Class "B") wiring. 2) When Note 2 under Installation. using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules ACCESSORIES and isolator bases. F110: Retrofit flange to convert B210LP(A) to match the B710LP(A) profile, or to convert older high-profile bases to Agency Listings and Approvals low-profile. These listings and approvals apply to the modules specified in F110BP: Bulk pack of F110;package contains 15. this document.ln some cases, certain modules or applications F210: Replacement flange for B210LP(A)base. may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. RA100Z(A): Remote LED annunciator. 3—32 VDC. Fits U.S. • UL Listed: S747. single-gang electrical box. Supported by B210LP(A) and • ULC Listed: S6978. 6501(A)bases only. • MEA Listed:383-02-E. SMB600: Surface mounting kit,flanged. • FM Approved. M02-04-00:Test magnet. • CSFM:7270-0028:0196. M02-09-00:Test magnet with telescoping handle. • BSMI:C1313066760025. XR2B: Detector removal tool. Allows installation and/or • CCCF: Certif.#2004081801000018. removal of FlashScan® Series detector heads from base in • U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 high ceiling installations. Includes T55-127-010. (NFS2-640/NFS-320/NFS-320C,excluding B210LP(A)). T55-127-010: Detector removal tool without pole. • Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- XP-4: Extension pole for XR2B. Comes in three 5-foot(1.524 320C,excluding B210LP(A)). m)sections. Product Line Information NOTE:"A"suffix indicates ULC Listed model. FST-851:Intelligent thermal detector.Must be mounted to one of the bases listed below. FST-851A:Same as FST-851 but with ULC Listing. FST-851R: Intelligent thermal detector with rate-of-rise fea- ture. FST-851RA:Same as FST-851R but with ULC Listing. FST-851H: Intelligent high-temperature thermal detector. FST 851 HA: Same as FST-851H but with ULC Listing. INTELLIGENT BASES NOTE:"A"suffix indicates ULC Listed model. NOTE:For details about intelligent bases and their mounting, see DN-60054. B210LP(A):Standard U.S.flanged low-profile mounting base. B210LPBP: Bulk pack of B210LP;package contains 10. B501(A):Standard European flangeless mounting base. B501BP: Bulk pack of B501;package contains 10. Notifier® and FlashScan® are registered trademarks of Honeywell B200S(A): Addressable Intelligent, programmable sounder International Inc. base capable of producing sound output in high or low volume ©2011thisoby Honeywelletisstrictly International Inc.All rights reserved.Unauthorized use of this document is prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERTF 1 E O We cannot cover all specific applications or anticipate all requirements. 01111 HIIN6 8 MANRFACDRINC All specifications are subject to change without QUALITY SYSTEMS notice. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. Made in the U.S.A. www.notifier.corn Page 2 of 2—DN-6936:B•12/07/2011 DNR(A)/DNRW InnovairFlex DN-60429:C1 Intelligent Non-Relay Photoelectric N ®T' F , E R® Duct Smoke Detector by Honeywell Intelligent Devices General The Notifier InnovairFlex®DNR(A) intelligent non-relay photo- electric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed t. as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and _ hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute(0.5 to 20.32 m/s), temperatures of-4°F to 158°F (-20°C to 70°C), g` and a humidity range of 0 to 95 percent(non-condensing.) ,. An improved cover design isoiates the sensor head, which Specifications allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperlyWidth,(Rectangle)(6. ecm) Depth.in (37 cm) Length; 5 in (12.7 cm) sensor cover. The Notifier InnovairFlex houing provides installed 3/ 2.5 in (6.6 4-inch conduit knockout and ample space to facilitate easy wir- Size:(Square)7.75 in(19.7 cm)Length;9 in(22.9 cm)Width; ing and mounting of a relay module. 2.5 in(6.35 cm)Depth. The Notifier InnovairFlex duct smoke detector can be custom- Weight: 1.6 lb(0.73 kg). ized to meet local codes and specifications without additional Operating Temperature Range: -4°F to 158°F (-20°C to wiring.The new InnovairFlex product line is compatible with all 70°C). previous Innovair models, including remote test accessories. Storage Temperature Range: -22°F to 158°F (-30°C to Features 70°C)- • Photoelectric, integrated low flow technology. Operating Humidity Range: 0% to 95% relative humidity (non-condensing). • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/s). Air Duct Velocity: 100 to 4,000 ft/min(0.5 to 20.32 m/s). • Versatile mounting options: square or rectangular configu ration. - Accessories • Broad ranges for operating temperature (-4°F to 158°F - Notifier provides system flexibility with a variety of accessories, 20°C to 70°C)and humidity(0%to 95%non-condensing). including two remote test stations and different means of visi • Patented sampling tube installs from front or back of the ble and audible system annunciation. As with our duct smoke detectors,all duct smoke detectors accessories are UL listed. detector with no tools required. • Cover tamper signal. DNR(W)s with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a • Increased wiring space with a newly added 3/4" conduitremote-test-capable knockout. detector. • Available space within housing to accommodate mounting ACCESSORY CURRENT LOADS AT 24 VDC of a relay module. • Easily accessible code wheels on sensor head (sold sepa Device Standby Alarm rately). RA100Z OmA 12 mA Max • Clear cover for convenient visual inspection. • Remote testing capability. RTS151/ RTS151KEY OmA 12mA Max • Requires corn line power only. • Accommodates the installation of an addressable relay module, sold separately, (FRM-1 or NC-100R) for applica Agency Listings and Approvals tions requiring a Form-C relay. Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. • UL: S911, S3705. • ULC:S635. DN-60429:C1 •4/19/2012—Page 1 of 2 • CSFM: 3242-1653:0209. • FM approved. Product Line Information NOTE:"A suffix indicates ULC listed model. DNR(A): Intelligent non-relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector(sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector(sold separately). FSP-851R(A): Remote test capable addressable low-profile photoelectric smoke detector. FSP-851(A): Addressable low-profile photoelectric smoke detector. NP-100:Addressable low-profile photoelectric smoke detector for FireWarden series panels. NP-100R(A): Remote test capable addressable low-profile photoelectric smoke detector for FireWarden series panels. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1(A):Metal sampling tube duct width up to 1 ft(0.3m). DST1.5(A): Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m). DST3(A):Metal sampling tube duct widths up to 2 ft to 4 ft(0.6 to 1.2 m). DST5(A):Metal sampling tube duct widths up to 4 ft to 8 ft(1.2 to 2.4 m). DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). DH4000E-1:Weatherproof enclosure. ETX:Metal exhaust tube duct,width 1 ft(0.3 m). M02-04-00:Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z(A): Remote annunciator alarm LED. RTS151(A): Remote test station. RTS151KEY(A): Remote test station with key lock. Important Note • DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. Notifier® and FlashScan® are a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. waassussf 1S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. py����erv�r- We cannot cover all specific applications or anticipate all requirements. annn[[IIIIA A All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. Made in the U.S.A. www.notifier.com Page 2 of 2—DN-60429:C1•4/19/2012 DN-6724:93 FCM-1 (A) & FRM-1 (A) Series 8 NOT 1 F 1 E R® Control and Relay Modules by Honeywell Intelligent/Addressable Devices General FCM-1(A)Control Module: The FCM-1(A)Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.).Addressability allows the FCM-1(A)to be acti- , % vated, either manually or through panel programming, on a itp select(zone or area of coverage)basis. FRM-1(A)Relay Module: The FRM-1(A) Addressable Relay 7 ri+6awa0 ....• Module provides the system with a dry-contact output for acti vating a variety of auxiliary devices, such as fans, dampers, TM•�"�"`"' "" control equipment,etc.Addressability allows the dry contact to • +►.a1 . .:.ii., .mhe� '' be activated, either manually or through panel programming, '"—"iitt • ,..H "�"° r on a select basis. FlashScan®(U.S. Patent 5,539,389) is a communication pro- „� tocol developed by NOTIFIER Engineering that greatly 2 enhances the speed of communication between analog intelli gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- i S • A mation, the panel CPU stops the group poll and concentrates on single points.The net effect is response speed greater than five times that of other designs. FCM-1(A) Features • Built-in type identification automatically identifies these • The FCM-1(A)is configured for a single Class B(Style Y)or devices to the control panel. Class A(Style Z)Notification Appliance Circuit. • Internal circuitry and relay powered directly by two-wire The FRM-1(A) provides two Form-C dry contacts that SLC loop.The FCM-1(A)module requires power(for horns, switch together. strobes,etc.),or audio(for speakers). • Integral LED "blinks" green each time a communication is Operation received from the control panel and turns on in steady red Each FCM-1(A)or FRM-1(A) uses one of 159 possible module when activated. addresses on a SLC loop (99 on CLIP loops). It responds to • LED blink may be deselected globally(affects all devices). regular polls from the control panel and reports its type and • High noise immunity(EMF/RFI). status, including the open/normal/short status of its Notifica- • The FCM-1(A) may be used to switch 24-volt NAC power, tion Appliance Circuit (NAC). The LED blinks with each poll audio(up to 70.7 Vrms). received. On command, it activates its internal relay. The • Wide viewing angle of LED. FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. • SEMS screws with clamping plates for wiring ease. Upon code command from the panel, the FCM-1(A) will dis- • Direct-dial entry of address 01— 159 for FlashScan loops, connect the supervision and connect the external power sup- 01 —99 for CLIP mode loops. ply in the proper polarity across the load device. The • Speaker, and audible/visual applications may be wired for disconnection of the supervision provides a positive indication Class B or A(Style Y or Z). to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- Applications munication loop so that a trouble condition on the external The FCM-1(A) is used to switch 24 VDC audible/visual power, power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door address may be set before or after mounting. The built-in holders or Air Handling Unit shutdown, and to reset four-wire TYPE CODE (not differ e)will identify the module to the con detector power. trot panel, so as to differentiate between a module and a sen- smokeNOTE: Refer to the SLC Manual(PN 51253) for details regarding sor address. releasing applications with the FCM-1(A). Refer to the FCM-I-REL datasheet(DN-60390)for new FlashScane releasing applications. Specifications for FCM-'l�/�� Normal operating voltage: 15 to 32 VDC. Construction Maximum current draw: 6.5 mA(LED on). • The face plate is made of off-white heat-resistant plastic. Average operating current: 350 pA direct poll,375 pA group • Controls include two rotary switches for direct-dial entry of poll with LED flashing, 485 pA Max. (LED flashing, NAC address(01-159). shorted.) •�� � �r���� �� w�� :tea,•--� �,�:, DN-6724:63•2/17/2011—Page 1 of 2 Maximum NAC Line Loss: 4 VDC. External supply voltage(between Terminals T10 and Contact Ratings for FRM-1(A) T11): Maximum (NAC): Regulated 24 VDC; Maximum Current Maximum Load (Speakers):70.7 V RMS,50W. Rating Voltage Description Application Drain on external supply: 1.7 mA maximum using 24 VDC 3 A supply;2.2 mA Maximum using 80 VRMS supply. 30 VDC Resistive Non-Coded Max NAC Current Ratings: For class B wiring system, the 2 A 30 VDC Resistive Coded current rating is 3A; For class A wiring system,the current 9 A 110 VDC rat- ing is 2A. Resistive Non-Coded .9 A 125 VDC Resistive Temperature range: 32°F to 120°F(0°C to 49°C). Non-Coded Humidity range: 10%to 93%non-condensing. 5 A 30 VDC Inductive (L/R=5ms) Coded Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1 A 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 30 VDC Inductive (L/R=2ms) Coded 2.125"(53.975 mm)deep box. Accessories: SMB500 Electrical Box;CB500 Barrier .3 A 125 VAC Inductive (PF=0.35) Non-Coded Specifications for FRM-1(A) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA(LED on). .7 A Inductive 70.7 VAC (PF=0.35) Non-Coded Average operating current: 230 pA direct poll;255 pA group poll. EOL resistance: not used. 2 A Inductive 25 VAC (PF=0.35) Non-Coded Temperature range: 32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%non-condensing. NOTE:Maximum(Speakers):70.7 V RMS,50 W Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x Product Line Information 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x NOTE: "suffix indicates ULC Listed model. 2.125"(53.975 mm)deep box. Accessories: SMB500 Electrical Box;CB500 Barrier FCM-1(A): Intelligent Addressable Control Module. FRM-1(A): Intelligent Addressable Relay Module. Agency Listings and Approvals A2143-20: Capacitor, required for Class A(Style Z)operation In some cases, certain modules may not be listed by certain of speakers. approval agencies, or listing may be in process. Consult fac- SMB500: Optional Surface-Mount Backbox. tory for latest listing status. • UL:S635 CB500: Control Module Barrier—required by UL for separat- ing power-limited and non-power limited wiring in the same • ULC:S3705(A version only) junction box as FCM-1(A). • FM Approved NOTE:For installation instructions,see the following documents: • CSFM:7300-0028:0219 • FCM-1(A)Installation document 156-1169. • MEA: 14-00-E • FRM-1(A)Installation document 156-3502. • FDNY:COA#6067,#6065 • Notifier SLC Wiring Manual,document 51253. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERT F E Ell We cannot cover all specific applications or anticipate all requirements. ...:.:. 91SIIE9INB 8 ::.::�. QUALITY SYSTEMS All specifications are subject to change without notice. -�-- For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. Made in the U.S.A. www.notifier.corn Page 2 of 2—DN-6724:55.2/17/2011 FMM-1 (A)' FMM-1 ®1 (A)' DN-6720:C•H-220 FZM-1 (A) & FDM-1 (A) 8 N®TIF 1 E R Monitor Modules with FlashScan® by Honeywell Intelligent/Addressable Devices General Four different monitor modules are available for Notifier's intel- ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and ,�. , power a circuit of two-wire smoke detectors(FZM-1(A)). l 3 FMM-1(A)is a standard-sized module(typically mounts to a 4" [10.16 cm]square box)that supervises either a Style D(Class •, A) or Style B(Class B)circuit of dry-contact input devices. 1e... '�Arra FMM-101(A)is a miniature monitor module a mere 1.3"(3.302 Al.2.1.6f UM Immo, cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that super- Pae */a vises a Style B (Class B) circuit of dry-contact input devices. Iwo^ Its compact design allows the FMM-101(A)to be mounted in a •s r single-gang box behind the device it monitors. a^� Gil FZM-1(A)is a standard-sized module that monitors and super- vises compatible two-wire,24 volt, smoke detectors on a Style r _ D(Class A) or Style B(Class B)circuit. f „ 1 R FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, FMM-1(A)(Type H) consecutive addresses in intelligent,two-wire systems. FlashScan®(U.S. Patent 5,539,389) is a communication pro- A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor tocol developed by NOTIFIER that greatly increases the speed (provided) terminates the Style B circuit. No resistor is of communication between analog intelligent devices. Intelli- required for supervision of the Style D circuit. gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU FMM-1(A) OPERATION stops the group poll and concentrates on single points. The Each FMM-1(A) uses one of the available module addresses net effect is response speed greater than five times that of on an SLC loop. It responds to regular polls from the control other designs. panel and of its Initiating oDev Device Circuit (IDC). Aype and the tflashing us nLEDnindicates FMM-1(A) Monitor Module that the module is in communication with the control panel. • Built-in type identification automatically identifies this device The LED latches steady on alarm (subject to current limita- tionsas a monitor module to the control panel. on the loop). • Powered directly by two-wire SLC loop. No additional power FMM-1(A) SPECIFICATIONS required. • Nominal operating voltage: 15 to 32 VDC. High noise(EMF/RFI)immunity. Maximum current draw:5.0 mA(LED on). • SEMS screws with clamping plates for ease of wiring. current: 350 p • Direct-dial entry of address: 01 — 159 on FlashScan loops; munication every 5 operatingAverage seconds,47k EOL.(LED flashing), 1 corn- 01 —99 on CLIP loops. • LED flashes green during normal operation (this is a pro- EOL resistance:47K ohms. Maximum IDC wiring resistance:40 ohms. grammable option) and latches on steady red to indicate alarm. Temperature range:32°F to 120°F(0°C to 49°C). The FMM-1(A) Monitor Module is intended for use in intelli- Humidity range: 10%to 93%noncondensing. gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x vides either a two-wire or four-wire fault-tolerant Initiating 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Device Circuit (IDC) for normally-open-contact fire alarm and 2.125"(5.398 cm)deep box. supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A)APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B(Class B) or Style D (Class DN-6720:C•10/06/2010—Page 1 of 4 FMM-101(A) Mini Monitor Module Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x • Built-in type identification automatically identifies this device 0.65"(1.651 cm)deep. as a monitor module to the panel. Wire length:6"(15.24 cm)minimum. • Powered directly by two-wire SLC loop. No additional power required. FZM-1(A) Interface Module • High noise(EMF/RFI) immunity. • Tinned,stripped • Supports compatible two-wire smoke detectors. leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct-dial entry of address: 01 — 159 on FlashScan loops; source. 01 —99 on CLIP loops. • High noise(EMF/RFI)immunity. ti • SEMS screws with clamping plates for ease of wiring. 8 13 1415 0 1 ADDRESS 0 1 • Direct-dial entry of address: 01 —159 on FlashScan loops, 3 12 j, 3 ', 2 01 —99 on CLIP loops. 3 ;o O� 4 LOOP ,� 4 • LED flashes during normal operation; this is a programma- 9 5 . O� 5 ble option. 8 6 9 8 6 • LED latches steady to indicate alarm on command from control panel. TENS ONES n n n The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This WY module allows intelligent panels to interface and monitor two- O LU U wire conventional smoke detectors. It transmits the status(nor- g mal, open,or alarm)of one full zone of conventional detectors 0o back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing sys- tems. I I I I FZM-1(A) APPLICATIONS The FMM-101(A) Mini Monitor Module can be installed in a The gang 1(A) omonitored unit. Its Use the FZM-1(A)to monitor a zone of two-wire smoke detec- single-gag junction light whet allow behind o the installed monitored unrigid tors. The monitored circuit may be wired as an NFPA Style B small size and FMM-101(A) iso itto intended for use in without intelligent,d (Class B)or Style D(Class A) Initiating Device Circuit.A 3.9 K motwo-wire systems where the individual address of each module ohm End-of-Line DL(cl ResistorB (provided)terminates the loopend of the resis- is selected using rotary switches. It provides a two-wire initiat- tStyle isB or (class Install or A) LR at across terminals IDC ing device circuit for normally-open-contact fire alarm and Style e 25 ohms). ELR across 8 and 9 for security devices. The FMM-101(A) can be used to replace Style D application. MMX-101(A)modules in existing systems. FZM-1(A)OPERATION FMM-101(A) Each FZM-1(A) uses one of the available module addresses Use to monitor a device or a zone of four-wire smoke on an SLC loop. It responds to regular polls from the control detectors,manual single alarm pull or stations,waterurdew 4 panel and reports its type and the status (open/normal/short) fireother normally-open dry-contact devices. May also be used to thatof its InitiatingoDevice communication mmt n cats A flashing LED indicates monitor normally-open supervisory devices with special super- the latches is in steady on alarm with thetcontrol panel. limita- visory indication at the control panel. Monitored circuit/device The LED the ops on alarm (subject to current is wired as an NFPA Style B(Class B) Initiating Device Circuit, tions on loop). A 47K ohm End-of-Line Resistor(provided)terminates the cir- FZM-1(A)SPECIFICATIONS cult. Nominal operating voltage: 15 to 32 VDC. FMM-101(A)OPERATION Maximum Each FMM-101(A) uses one of the available module Maximum IDCrent draw:5.1 mA LED on). wiring resistance:25 ohms. addresses on an SLC loop. It responds to regular polls from Average operating current: 300 pA, 1 communication and 1 the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). LED flash every 5 seconds,3.9k eol. EOL resistance:3.9K ohms. FMM-101(A) SPECIFICATIONS External supply voltage (between Terminals T3 and T4): Nominal operating voltage: 15 to 32 VDC. C Average operating current: 350 pA, 1 communication every max mlum. Cu rent:24ts 90 mA perpowernited.module'maxe imulm ge 0.1 Vrms 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shoted). Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Maximum IDC wiring resistance:40 ohms. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC Voltage: 11 Volts. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Maximum IDC Current:400 pA. 2.125"(5.398 cm)deep box. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6720:C•10/06/2010 FDM1(A) Dual Monitor Module -161.002/23/3 (AFP-200:FMM-1/-101,FZM-1) The FDM-1(A) Dual Monitor Module is intended for use in intelli- —161.002/42/1 (NFS 640:FMM 1/101) gent, two-wire systems. It provides two independent two-wire • Lloyd's Register: initiating device circuits (IDCs) at two separate, consecutive addresses.It is capable of monitoring normally open contact fire —03/60011/E1 (FMM-1/--101, FZM-1) alarm and supervisory devices; or either normally open or nor —94/60004/E2 (AFP-200:except FDM-1) mally closed security devices. The module has a single panel- —02/60007(NFS-640:FDM-1) controlled LED. • FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 NOTE: The FDM-1(A)provides two Style B(Class B)IDC circuits (NFS2-3030) ONLY Style D(Class A) IDC circuits are NOT supported in any application. Product Line Information FDM-1(A)SPECIFICATIONS NOTE:"A"suffix indicates ULC-listed model. Normal operating voltage range: 15 to 32 VDC. Maximum current draw:6.4 mA(LED on). FMM-1(A):Monitor module. FMM-101(A):Monitor module, miniature. Average operating current:750 pA(LED flashing). FZM-1(A):Monitor module,two-wire detectors. Maximum IDC wiring resistance: 1,500 ohms. FDM-1(A):Monitor module,dual,two independent Class B cir- Maximum IDC Voltage: 11 Volts. cults. SMB500:Optional surface-mount backbox. Maximum IDC Current:240 pA NOTE: See installation instructions and refer to the SLC Wiring EOL resistance:47K ohms. Maximum SLC Wiring resistance:40 Ohms. Manual,PN 51253. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125"(5.398 cm)deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A)automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically assign itself to addresses"26"and"27". NOTE:"Ones"addresses on the FDM-1(A)are 0,2,4,6,or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. A CAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box.They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A)module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes,ordinances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635 • ULC:S635 • FM Approved • CSFM:7300-0028:0219 • MEA:457-99-E • U.S.Coast Guard: 411101B1.- seMPORNAMIIIIMMININES DN-6720:C•10/06/2010—Page 3 of 4 FlashScan®and NOTIFIER®are registered trademarks and FireWatchTM is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T P E We cannot cover all specific applications or anticipate all requirements. ; 6YBINEL1ilN6 S MlWAFACE M S All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. Made in the U.S.A. www.notifier.com Page 4 of 4—DN-6720:C•10/06/2010 NBG-1 2LX DN-6726:D•H-240 Addressable Manual Pull Station 8 NOTIFIER.®T' F' ER® by Honeywell f ;� `,�� i Intelligent/Addressable Devices `General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligentfe 1 - --, v, control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the PUSH IN alarm. PULL DCY1 N , Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady �', red when in alarm. OrsoYtFIE61 • Handle latches in down position and the word`ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop(accepts up to 12 AWG/3.25 mm2 wire). The NBG-12LX • Can be surface mounted (with SB-10 or SB-I/O) or semi- Addressable Manual Pull Station flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4"(10.16 cm)square electrical box. Installation • Smooth dual-action design. The NBG-12LX will mount semi-flush into a single-gang, dou- • Meets ADAAG controls and operating mechanisms guide- ble-gang, or standard 4" (10.16 cm) square electrical outlet lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. box, or will surface mount to the model SB-10 or SB-I/O sur- maximum activation force. face backbox. If the NBG-12LX is being semi-flush mounted, • Highly visible. then the optional trim ring (BG12TR) may be used. The • Attractive shape and textured finish. BG12TR is usually needed for semi-flush mounting with 4" • Key reset. (10.16 cm)or double gang boxes(not with single gang boxes). • Includes Braille text on station handle. Operation • Optional trim ring(BG12TR). Pushing in, then• Meets UL 38, Standard for Manually Actuated Signaling in the down/activated pos position. llatchatched,n. Oncehandle down on the the wo dt"ACTI- Boxes. VATED" (in bright yellow) appears at the top of the handle, • Up to 99 NBG-12LX stations per loop on CLIP protocol while a portion of the handle protrudes from the bottom of the loops. station. To reset the station, simply unlock the station with the • Up to 159 NBG-12LX stations per loop on FlashScan®pro- key and pull the door open.This action resets the handle;clos- tocol loops. ing the door automatically resets the switch. • Dual-color LED blinks green to indicate normal on Each manual station, on command from the control panel, FlashScan®systems. sends data to the panel representing the state of the manual switch.Two rotary decimal switches allow address settings Construction (1 —159 on FlashScan®systems, 1 —99 on CLIP systems). Shell, door, and handle are molded of durable polycarbonate Architectural/Engineering material with a textured finish. Specifications Specifications Manual Fire Alarm Stations shall be non-coded, with a• Shipping Weight:9.6 oz. (272.15 g) key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot • Normal operating voltage:24 VDC. be restored to normal except by use of a key.An operated sta- • Maximum SLC loop voltage:28.0 VDC. tion shall automatically condition itself so as to be visually • Maximum SLC standby current:375 pA. detected as activated. Manual stations shall be constructed of • Maximum SLC alarm current:5 mA. red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall • Temperature Range:32°F to 120°F(0°C to 49°C) appear on the front of the stations in white letters, 1.00 inches • Relative Humidity: 10%to 93%(noncondensing) (2.54 cm) or larger. Stations shall be suitable for surface • For use indoors in a dry location mounting on matching backbox SB-10 or SB-I/O;or semi-flush mounting on a standard single-gang, double-gang, or DN-6726:D•4/13/2012—Page 1 of 2 4"(10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10:Surface backbox;metal. SB-I/O: Surface backbox; plastic. BG12TR:Optional trim ring. 17021: Keys,set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E. • CSFM:7150-0028:0199. • FDNY: COA#6085 (NFS2-640),COA#6098(NFS2-3030). • BSMI:CI313066760047. • U.S.Coast Guard. • Lloyd's Register. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ASO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERT/r- E 6 We cannot cover all specific applications or anticipate all requirements. MiIEINIBMAIIiIfi1C1WM All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. Made in the U.S.A. www.notifier.corn Page 2 of 2—DN-6726:D•4/13/2012VIIIKONIMMINOMMISOMINIMINNAMIMINI DN-60918:A Indoor Selectable-Output Horns, Strobes, and Horn NOTIFIER Strobes for Wall Applications by Honeywell AudioNisual Devices General The L-Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry with lower cur- rent draws and modern aesthetics. With white and red plastic F housings, standard and small footprint devices, and plain, FIRE-printed devices, L-Series can meet virtually any applica- tion requirement. The L-Series product line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their ar> application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually elim- P2RL inating costly and time-consuming ground faults. To further simplify installation and protect devices from con- struction damage, L-Series utilizes a universal mounting plate for all standard and compact models with an onboard shorting spring,so installers can test wiring continuity before the device F is installed. I l Installers can also easily adapt devices to a suit a wide range R =At --'4 RE of application requirements using field-selectable candela set- A, • E� � tings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Features P2GWL SGWL • Updated modern aesthetics. • Small profile devices for Horns and Horn Strobes. • Plug-in design with minimal intrusion into the back box. • Tamper-resistant construction. Isr� • Automatic selection of 12-or 24-volt operation at 15 and 30 i�S candela. oy • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135,and 185. • Horn rated at 88+dBA at 16 volts. • Rotary switch for horn tone and two volume selections. • Universal mounting plate for all standard and all compact wall units. HWL • Mounting plate shorting spring checks wiring continuity. before device installation. • Electrically Compatible with legacy SpectrAlert® and 12 or 24 volts. When used with the Sync•Circuit Module, 12- SpectrAlert Advance devices. volt-rated notification appliance circuit outputs shall operate • Compatible with MDL3 sync module. between 8.5 and 17.5 volts; 24-volt-rated c appliance circuit Listed for wall mounting only. outputs shall operate between 16.5 and 33 volts. Indoor • L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unaltered Architectural/Engineering Specifications power supply.Strobes and horn strobes shall have field-select- General: L-Series standard horns, strobes, and horn strobes able candela settings including 15, 30, 75, 95, 110, 135, and shall mount to a standard 2" x 4" x 17/8" back box, 4" x 4" x 185. 11/2" back box, 4"octagon back box, or double-gang back box. Strobe. The strobe shall be a L-Series Model listed to UL L-Series compact products shall mount to a single-gang 2" x 1971 and shall be approved for fire protective service. The 4" x 1'/8" back box. A universal mounting plate shall be used strobe shall be wired as a primary-signaling notification appli- for mounting ceiling and wall products for all standard-size ance and comply with the Americans with Disabilities Act models and a separate universal mounting plate shall be used requirements for visible signaling appliances, flashing at 1 Hz for mounting compact wall models. The notification appliance over the strobe's entire operating voltage range. The strobe circuit wiring shall terminate at the universal mounting plate. light shall consist of a xenon flash tube and associated lens/ Also, L-Series products, when used with the Sync•CircuitTM reflector system. Module accessory, shall be powered from a non-coded notifi- cation appliance circuit output and shall operate on a nominal DN-60918:A•2/3/2017—Page 1 of 4 Horn Strobe Combination. The horn strobe shall be a L-Series Model listed to UL 1971 and UL 464 and shall be L-Series Drawings approved for fire protective service. The horn strobe shall be Compact Horn wired as a primary-signaling notification appliance and comply r-I with the Americans with Disabilities Act requirements for visi- = 3.46 = ble signaling appliances, flashing at 1 Hz over the strobe's 1.25 entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The - \ horn shall have two audibility options and an option to switch "' fik.' �� '� between a temporal three pattern and a non-temporal (contin- l'o'o' 1;l' I uous) pattern. These options are set by a multiple position o 00 000 switch. The horn on horn strobe models shall operate on a 5.27 1 '00000000000, coded or non-coded power supply. a o 0 0 0, ,;00000000, Synchronization Module.The module shall be a Sync•Circuit ' i000000000o i model MDL3 listed to UL 464 and shall be approved for fire .111111, ,i' protective service. The module shall synchronize SpectrAlert `�p J�' - strobes at 1 Hz and horns at temporal three.Also, while oper- ating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/6" x 411/18" x 21/8" back box. The module shall Compact Combo also control two Style Y(class B)circuits or one Style Z(class A)circuit. The module shall synchronize multiple zones. Daisy 1.91 chaining two or more synchronization modules together will 3.46 synchronize all the zones they control. The module shall not = - 1.2E operate on a coded power supply. ,u • ...,� PHYSICAL/ELECTR/CAL SPECIFICATIONS """'u"�' • Standard Operating Temperature: 32°F to 120°F (0°C to 4I.:44601). 5.27 • Humidity Range: 10 to 93%non-condensing. • Strobe Flash Rate: 1 flash per second. • Nominal Voltage: Regulated 12 DC or regulated 24 DC/ ' ,ei FWR1 (full wave rectified). • Operating Voltage Rangel: 8 to 17.5 V (12 V nominal) or 16 to 33 V(24 V nominal). • Operating Voltage Range: MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal). Horn • Input Terminal Wire Gauge: 12 to 18 AWG. = r• Wall-Mount Dimensions(including lens):5.6" L x 4.7"W 4'70 1.25 x 1.25"D(143 mm L x 119 mm W x 32 mm D). • Compact Wall-Mount Dimensions(including lens):5.26" /r.,,.;,..111 L x 3.46"W x 1.93"D(133 mm L x 88 mm W x 49 mm D). 1 ;-;: -y.'^ • Horn Dimensions:5.6" L x 4.7"W x 1.25" D(143 mm L x -.r: 119mmWx32mmD). 5.67 """"�" � ' '111.1 • Compact Horn Dimensions: 5.25" L x 3.45"W x 1.25" D �; gg% I. (133mm L x 88mm W x 32mm D). Notes: , oJJI 1. Full Wave Rectified (FWR)voltage is a non-regulated,time- varying power source that is used on some power supply and panel outputs. Combo 2. P,S, PC, and SC products will operate at 12 V nominal only for 15 cd and 30 cd. e 4.70 - - 1.91 _= 1.25 /!l 5.67 drill•''"'`• "[I \1 AnatillaIllEVIIIIIMIONIMIF Page 2 of 4—DN-60918:A•2/3/2017 UL Current Draw Data UL MAX.HORN CURRENT DRAW(MA RMS) UL MAX. STROBE CURRENT DRAW(MA RMS) 8-17.5 8-17.5 Volts 16-33 Volts Volts 16-33 Volts Sound Pattern dB DC DC FWR Candela DC DC FWR Temporal High 39 44 54 15 88 43 60 Temporal Low 28 32 54 30 143 63 83 Non-Temporal High 43 47 54 75 N/A 107 136 Non-Temporal Low 29 32 54 95 N/A 121 155 3.1 KHz Temporal High 39 41 54 110 N/A 148 179 3.1 KHz Temporal Low 29 32 54 135 N/A 172 209 3.1 KHz Non-Temporal High 42 43 54 185 N/A 222 257 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL MAX. CURRENT DRAW(MA RMS),2-WIRE HORN STROBE, CANDELA RANGE(15-115 CD) DC Input: DC Input: 8-17.5 Volts 16-33 Volts FWR Input: 16 FWR 15 30 15 30 75 95 110 135 185 15 30 75 95 110 135 185 cd cd cd cd cd cd cd cd cd cd cd cd cd cd cd cd EM Temp Hi 98 158 54 74 121 142 162 196 245 83 107 156 177 198 234 287 EM Temp Low 93 154 44 65 111 133 157 184 235 68 91 145 165 185 223 271 EM Cont Hi 106 166 73 94 139 160 182 211 262 111 135 185 207 230 264 316 EM Cont Low 93 156 51 71 119 139 162 190 239 79 104 157 175 197 235 283 3.1K Temp Hi 93 156 53 73 119 140 164 190 242 81 105 155 177 196 234 284 3.1K Temp Low 91 154 45 66 112 133 160 185 235 68 90 145 166 186 222 276 3.1K Cont Hi 99 162 69 90 135 157 175 208 261 104 131 177 204 230 264 326 3.1k Cont Low 93 156 52 72 119 138 162 192 242 77 102 156 177 199 234 291 HORN TONES AND SOUND OUTPUT DATA:HORN AND HORN STROBE OUTPUT(DBA) 8-17.5 Volts 16-33 Volts Pos. Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Von-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7t 3.1 KHz Non-Temporal High 84 89 89 8t 3.1 KHz Non-Temporal Low 77 83 83 9t Coded High 85 90 90 10 3.1 KHz Coded High 84 89 89 DN-60918:A•2/3/2017—Page 3 of 4 Agency Listings and Approvals The listings and approvals below apply to L-series devices. In some cases,certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC-Listed —S4011 Wall Horn Strobes —S5512 Wall Strobes —S5512 Wall Horns • FM Approved Product Line Information Note: ULC-listed devices include required French labeling. See Agency Listings for listing details. WALL HORN STROBES P2WL(A),P2RL(A).2-Wire, Horn Strobe(White, Red). P2GWL(A), P2GRL(A).2-Wire, Compact Horn Strobe(White, Red). P2WL(A)-P, P2RL(A)-P. 2-Wire, Horn Strobe, Plain (White, Red). P2WL-SP, P2RL-SP. 2-Wire, Horn Strobe, FUEGO (White, Red). WALL STROBES SWL(A),SRL(A).Strobe, Red(White, Red). SGWL(A),SGRL(A).Compact Strobe(White, Red). SWL(A)-P,SRL(A)-P.Strobe, Plain(White, Red). SRL-SP.Strobe, FUEGO(Red). SWL-CLR-ALERT.Strobe,ALERT(White). SWL-ALERT.Strobe,Wall,Amber Lens,Alert(White). HORNS HWL(A),HRL(A). Horn(White, Red). HGWL(A),HGRL(A).Compact Horn(White, Red). ACCESSORIES TR-2W,TR-2. Universal Wall Trim Ring(White, Red). SBBWL,SBBRL.Wall Surface Mount Back Box(White, Red). SBBGWL, SBBGRL. Compact Wall Surface Mount Back Box (White, Red). Notes: • All -P models have a plain housing (no "FIRE" marking on cover). • All-SP models have"FUEGO"marking on cover. • All-ALERT models have"ALERT"marking on cover. • ULC-listed"A"models have FIRE/FEU marking on cover. NOTIFIER® and SpectrAlert® are registered trademarks and Sync•CircuitTM is a trademark of Honeywell International Inc. ©2017 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 4c.-1 t F o We cannot cover all specific applications or anticipate all requirements. EIMME IMSMANIRIMMI All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-60918:A•2/3/2017 DN-60938:A Indoor Selectable-Output Strobes and Horn Strobes for 8 N OT I F 1 E R° Ceiling Applications by Honeywell Audio/VisualDevices General System Sensor L-Series audible visible notification products .., are rich with features guaranteed to cut installation times and _- maximize profits with lower current draw and modern aesthet- ics. The System Sensor L.-Series offers the most versatile ( and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With aifi white and red plastic housings, wall and ceiling mounting 'o 44 AP• options, System Sensor L-Series can meet virtually any appli- ". cation requirement. 'j The entire L-Series product line of ceiling-mount strobes and SCRL PC2WL horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back Architect/Engineer Specifications box, making installations fast and foolproof while virtually elim- GENERAL inating costly and time-consuming ground faults. To further simplify installation, the L-Series utilizes a universal L-Series ceiling-mount strobes and horn strobes shall mount mounting plate so installers can mount them to a wide arrayof to a standard 4 x 4 x 1 c inch back box, productsinch octagon back also back boxes. With an onboard shorting spring, installers can box, or double gang back box. Two-wire shall also test wiring continuity before the device is installed. mount to a single-gang 2 x 4 x 1'/8 inch back box.A universal mounting plate shall be used for mounting ceiling and wall Installers can also easily adapt devices to a suit a wide range products. The notification appliance circuit wiring shall termi- of application requirements using field-selectable candela set- nate at the universal mounting plate. Also, L-Series products, tings, automatic selection of 12- or 24-volt operation, and a when used with the Sync•Circuit r Module accessory, shall be rotary switch for horn tones with two volume selections. powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with Features the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24- • Plug-in design with minimal intrusion into the back box volt-rated notification appliance circuit outputs shall operate • Tamper-resistant construction between 16.5 and 33 volts. Indoor L-Series products shall • Automatic selection of 12-or 24 volt operation operate between 32 and 120 degrees Fahrenheit from a regu- at 15 and 30 candela lated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela • Field selectable candela settings on ceiling units: 15,30,75,95, 115, 150, and 177 settings including 15,30, 75,95, 115, 150,and 177. • Horn rated at 88+dBA at 16 volts STROBE • Rotary switch for horn tone and two volume selections The strobe shall be a System Sensor L-Series Model • Universal mounting plate for ceiling units listed to UL 1971 and shall be approved for fire protective ser- • Mounting plate shorting spring feature checks wiringConti- vice.The strobe shall be wired as a primary-signaling Disabilities before device installation tion appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 • Electrically compatible with legacy SpectrAlert and Hz over the strobe's entire operating voltage range.The strobe SpectrAlert Advance devices light shall consist of a xenon flash tube and associated lens/ • Compatible with MDL3 sync module reflector system. • Listed for ceiling mounting only HORN STROBE COMBINATION The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signal- ing appliances,flashing at 1 Hz over the strobe's entire operat- ing voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pat- tern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non- coded power supply. DN-60938:A•2/3/2017—Page 1 of 4 SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/76 x 21/8 inch back box.The module shall also con- trol two Style Y (class B) circuits or one Style Z (class A) cir- cuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAL/ELECTRICAL SPECIFICATIONS • Standard Operating Temperature: 32°F to 120°F (0°C to 49°C) • Humidity Range: 10 to 93%non-condensing • Strobe Flash Rate: 1 flash per second • Nominal Voltage: Regulated 12VDC or regulated 24DC/ FWR1 • Operating Voltage Rangel: 8 to 17.5V (12V nominal) or 16 to 33V(24V nominal) • Operating Voltage Range with MLD3: 8.5 to 17.5V (12V nominal)or 16.5 to 33V(24V nominal) • Input terminal wire gauge: 12 to 18 AWG • Ceiling-Mount Dimensions (including lens): 6.8" diame- ter 2.5"high(173 mm diameter 64 mm high) • Ceiling-Mount Surface Mount Back Box Skirt Dimen- sions (SBBCR, SBBCW): 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR)voltage is a non-filtered, time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. UL Current Draw Data UL MAX.STROBE CURRENT DRAW(MA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 °This data represents coding at 3 chimes per second. Actual current draw will vary depending upon coding selected. Page 2 of 4—DN-60938:A•2/3/2017 UL MAX, CHIME/STROBE CURRENT DRAW(MA RMS),2-WIRE HORN STROBE 8VDC 16VDC Candela 15 30 15 30 75 95 115 150 177 EM Temp Hi 103 167 71 90 143 165 187 217 254 EM Temp Low 96 165 54 71 137 161 185 211 249 EM Cont Hi 106 173 71 90 141 165 187 230 273 EM Cont Low 95 166 54 71 124 161 170 216 258 3.1K Temp Hi 111 164 69 94 147 163 184 229 3.1K Temp Low 103 163 54 257 88 143 155 185 212 252 3.1K Cont Hi 111 172 69 94 144 164 202 229 271 3.1K Cont Low 103 169 54 88 131 155 187 217 259 16VFWR Candela 15 30 75 95 115 150 177 EM Temp Hi 107 135 179 198 223 254 286 EM Temp Low 78 101 151 172 199 229 262 EM Cont Hi 107 135 179 198 223 254 286 EM Cont Low 78 101 151 172 199 229 262 3.1K Temp Hi 108 135 179 200 225 255 289 3.1K Temp Low 79 101 150 171 196 229 260 3.1K Cont Hi 108 135 179 200 225 255 289 3.1K Cont Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data HORN AND HORN STROBE OUTPUT(DBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 DN-60938:A•2/3/2017—Page 3 of 4 Product Drawings: L-Series Dimensions 2.47 0 6.83 1.37 0 6.92 2.50 a p„, 000gci,\ ..,, . 0 ''',,*,..•-_ , ::‘‘-. E„' goo ®$ 9, Itionwori t Horn Strobes (Ceiling) Surface Mount Back Box(Ceiling) Agency Listings and Approvals The listings and approvals below apply to L-series devices. In some cases,certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC-Listed —S4011 Ceiling horn strobes —S5512 Ceiling strobes —S5512 ALERT strobes with clear lenses • FM Approved Product Line Information Note: ULC-listed devices include required French labeling. See Agency Listings for listing details. CEILING HORN STROBES PC2WL,PC2RL.2-Wire, Horn Strobe(White, Red). CEILING STROBES SCWL,SCRL.Strobe(White,Red). SCWL-CLR-ALERT.Strobe,ALERT(White). ACCESSORIES TR-2W,TR-2.Universal Wall Trim Ring(White, Red). SBBCWL,SBBCRL. Ceiling Surface Mount Back Box(White, Red). NOTIFIER® and SpectrAlert© are registered trademarks and Sync•CircuitTM is a trademark of Honeywell International Inc. ©2017 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T F E o We cannot cover all specific applications or anticipate all requirements. INI EHIIUILMM USTMIjM All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-60938:A•2/3/2017 Indoor Selectable-Output DN-60918:A Horns, Strobes, and Horn NOTIFIER Strobes for Wall Applications by Honeywell General AudioNisual Devices The L-Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry with lower cur- rent draws and modern aesthetics. With white and red plastic housings, standard and small footprint devices, and plain, FIRE-printed devices, L-Series can meet virtually any applicaI - tion requirement. , .. ,. ,1%._,* f p The L-Series product line of wall-mount horns, strobes, and horn strobes include a variety of features that ^�' increase their - ,ti, -- application versatility while simplifying installation. All devices T' feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually elim- P2RL inating costly and time-consuming ground faults. To further simplify installation and protect devices from con- struction damage, L-Series utilizes a universal mounting plate for all standard and compact models with an onboard shorting spring,so installers can test wiring continuity before the device is installed. l ,,!kfff', F F Installers can also easily adapt devices to a suit a wide range RI of application requirements using field-selectable candela set- E tings, automatic selection of 12- or 24-volt operation, and a / E rotary switch for horn tones with two volume selections. t4 Features P2GWL SGWL • Updated modern aesthetics. • Small profile devices for Horns and Horn Strobes. • Plug-in design with minimal intrusion into the back box. • Tamper-resistant construction. • Automatic selection of 12-or 24-volt operation at 15 and 30 �,� 1111111 candela. �;1;,;, • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135,and 185. • Horn rated at 88+dBA at 16 volts. • Rotary switch for horn tone and two volume selections. +y • Universal mounting plate for all standard and all compact wall units. • Mounting plate shorting spring checks wiring continuity. HWL before device installation. • Electrically Compatible with legacy SpectrAlert® and 12 or 24 volts. When used with the Sync•Circuit Module, 12- • SpectrAlert Advance devices. volt-rated notification appliance circuit outputs shall operate Compatible with MDL3 sync module. between 8.5 and 17.5 volts; 24-volt-rated c appliance circuit • Listed for wall mounting only. outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regated DC or full-waveArchitectural/Engineering Specifications power supply.Strobes and horn strobes hallrhavied e field-see ct able candela settings including 15, 30, 75, 95, 110, 135, and General: L-Series standard horns, strobes, and horn strobes shall mount to a standard 2"x 4" x 17/8" back box, 4" x 4" x 185. 1'/2"back box, 4"octagon back box, or double-gang back box. Strobe. The strobe shall be a L-Series Model listed to UL L-Series compact products shall mount to a single-gang 2" x 1971 and shall be approved for fire protective service. The 4" x 1'/$" back box. A universal mounting plate shall be used strobe shall be wired as a primary-signaling notification appli- for mounting ceiling and wall products for all standard-size ance and comply with the Americans with Disabilities Act models and a separate universal mounting plate shall be used requirements for visible signaling appliances, flashing at 1 Hz for mounting compact wall models. The notification appliance over the strobe's entire operating voltage range. The strobe circuit wiring shall terminate at the universal mounting plate. light shall consist of a xenon flash tube and associated lens/ Also, L-Series products, when used with the Sync•Circuitno reflector system. Module accessory, shall be powered from a non-coded notifi- cation appliance circuit output and shall operate on a nominal Horn Strobe Combination. The horn strobe shall be a L-Series Model listed to UL 1971 and UL 464 and shall be L�Ser1eS Drawings approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply Compact Horn with the Americans with Disabilities Act requirements for visi- 3.46 - ble signaling appliances, flashing at 1 Hz over the strobe's 1.25 entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The / ►�\ horn shall have two audibility options and an option to switch �,� "qui,...,q`1Y between a temporal three pattern and a non-temporal (contin- uous) pattern. These options are set by a multiple position il switch. The horn on horn strobe models shall operate on a 0000O�000a coded or non coded power supply. p 5'27 ' 000000°os, , O46:6:44 000�0 0® Synchronization Module.The module shall be a S nc• oe°000eoeo modelY Circuit ioioeoi000 MDL3 listed to UL 464 and shall be approved for fire ri `'000000000 J i' ,` protective service. The module shall synchronize SpectrAlert _ L strobes at 1 Hz and horns at temporal three.Also, while oper- ating ��� the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/6" x 4"/16" x 21/8" back box. The module shall also control two Style Y(class B) circuits or one Style Z(class Compact Combo A)circuit. The module shall synchronize multiple zones. Daisy = chaining two or more synchronization modules together will 1.91 synchronize all the zones they control. The module shall not 3.46 operate on a coded power supply. 1'2E 11.11014111111 PHYSICAL/ELECTRICAL SPECIFICATIONS • ,' ! �1. � • Standard Operating Temperature: 32°F to 120°F (0°C to 00h -et49°C). •1...1.1.1.1• • Humidity Range: 10 to 93%non-condensing. 5.27 . • Strobe Flash Rate: 1 flash per second. ono• Nominal Voltage: Regulated 12 DC or regulated 24 DC/ `�-1 " FWR1 (full wave rectified). _11 Nils"� • Operating Voltage Rangel: 8 to 17.5 V(12 V nominal) or 16 to 33 V(24 V nominal). • Operating Voltage Range: MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal). • Input Terminal Wire Gauge: 12 to 18 AWG. Horn • Wall-Mount Dimensions(including lens):5.6"L x 4.7"W 4.70 x 1.25"D(143 mm L x 119 mmWx32mmD). _ 1.25 r rh----h---- • Compact Wall-Mount Dimensions(including lens):5.26" L x 3.46"W x 1.93"D(133 mm L x 88 mm W x 49 mm D). -' • Horn Dimensions: 5.6" L x 4.7"W x 1.25" D(143 mm L x - 119mmWx32mmD). 5.67 • Compact Horn Dimensions: 5.25" L x 3.45"W x 1.25" D �.�, (133mm L x 88mm W x 32mm D). ;- �;�;^,'J , IN Notes: „ _o_ 1. Full Wave Rectified(FWR)voltage is a non-regulated,time- varying power source that is used on some power supply and panel outputs. 2. P, S, PC,and SC products will operate at 12 V nominal only a Combo for 15 cd and 30 cd. 4.70 1.91 1.25 ii Iiir- 5.67 •''''''''`• JilL. SII i,. / 111 Page 2 of 4—DN-60918:A•2/3/2017 UL Current Draw Data UL MAX. HORN CURRENT DRAW(MA RMS) UL MAX. STROBE CURRENT DRAW(MA RMS) 8-17.5 8-17.5 Volts 16-33 Volts Volts 16-33 Volts Sound Pattern dB DC DC FWR Candela DC DC FWRTemporal High 39 44 54 15 88 43 60 Temporal Low 28 32 54 30 143 63 83 Non-Temporal High 43 9 47 54 Non-Temporal Low 29 32 54 75 N/A 107 136 3.1 KHz Temporal High 39 41 54 95 N/A 121 155 3.1 KHz Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Non-Temporal High 42 43 54 135 N/A 172 209 3.1 KHz Non-Temporal Low 28 29 54 185 N/A 222 257 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL MAX. CURRENT DRAW(MA RMS),2-WIRE HORN STROBE, CANDELA RANGE(15-115 CD) DC Input: ' DC Input: 8-17.5 Volts 16-33 Volts FWR Input: 15 30 15 16 FWR 30 75 95 110 135 185 15 30 75 95 110 135 185 cd cd cd cd cd cd cd cd cd cd cd cd cd cd cd cd EM Temp Hi 98 158 54 74 121 142 162 196 245 83 107 156 177 198 234 287 EM Temp Low 93 154 44 65 111 133 157 184 235 68 91 145 165 185 223 271 EM Cont Hi 106 166 73 94 139 160 182 211 262 111 135 185 207 230 264 316 EM Cont Low 93 156 51 71 119 139 162 190 239 79 104 157 175 197 235 283 3.1K Temp Hi 93 156 53 73 119 140 164 190 242 81 105 155 177 196 234 284 3.1K Temp Low 91 154 45 66 112 133 160 185 235 68 90 145 166 186 222 276 3.1K Cont Hi 99 162 69 90 135 157 175 208 261 104 131 177 204 230 264 326 3.1k Cont Low 93 156 52 72 119 138 162 192 242 77 102 156 177 199 234 291 HORN TONES AND SOUND OUTPUT DATA:HORN AND HORN STROBE OUTPUT(DBA) 8-17.5 Volts 16-33 Volts Pos. Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Von-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7t 3.1 KHz Non-Temporal High 84 89 89 8t 3.1 KHz Non-Temporal Low 77 83 83 9f Coded High 85 90 90 10 3.1 KHz Coded High 84 89 89 Agency Listings and Approvals The listings and approvals below apply to L-series devices. In some cases,certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UUULC-Listed —S4011 Wall Horn Strobes —S5512 Wall Strobes —S5512 Wall Horns • FM Approved Product Line Information Note: ULC-listed devices include required French labeling. See Agency Listings for listing details. WALL HORN STROBES P2WL(A), P2RL(A).2-Wire, Horn Strobe(White, Red). P2GWL(A), P2GRL(A).2-Wire, Compact Horn Strobe(White, Red). P2WL(A)-13, P2RL(A)-P. 2-Wire, Horn Strobe, Plain (White, Red). P2WL-SP, P2RL-SP. 2-Wire, Horn Strobe, FUEGO (White, Red). WALL STROBES SWL(A),SRL(A).Strobe, Red(White, Red). SGWL(A),SGRL(A).Compact Strobe(White, Red). SWL(A)-P,SRL(A)-P.Strobe, Plain(White, Red). SRL-SP.Strobe, FUEGO(Red). SWL-CLR-ALERT.Strobe,ALERT(White). SWL-ALERT.Strobe,Wall,Amber Lens,Alert(White). HORNS HWL(A),HRL(A). Horn(White, Red). HGWL(A),HGRL(A).Compact Horn (White, Red). ACCESSORIES TR-2W,TR-2. Universal Wall Trim Ring(White, Red). SBBWL,SBBRL.Wall Surface Mount Back Box(White, Red). SBBGWL, SBBGRL. Compact Wall Surface Mount Back Box (White, Red). Notes: • All -P models have a plain housing (no "FIRE" marking on cover). • All-SP models have"FUEGO"marking on cover. • All-ALERT models have"ALERT"marking on cover. • ULC-listed"A"models have FIRE/FEU marking on cover. NOTIFIER® and SpectrAlert® are registered trademarks and Sync•CircuitTM is a trademark of Honeywell International Inc. ©2017 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T F E p We cannot cover all specific applications or anticipate all requirements. 6IRUEHIIIU R MAIYRMCBRIIM All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. raw 41802112.1MINIM www.notifier.com , . r Page 4 of 4—DN-60918:A•2/3/2017 �N 6ThSYSTEM $ SENSOR® ofk Outdoor Selectable.. blevim Output Strobes and Horn Strobes for Ceiling Applications -7•413 SpectrAlerto Advance outdoor audible visible products are rich with features that cut installation times and SPECTR! uert taimeragialailferi maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof NEMA 4X, IP56 rated strobes,and horn strobes in the industry.With white or red plastic • Listed to UL 1638(strobe)and UL 464(horn) housings,wall or ceiling mounting options,and plain or FIRE-printed devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor strobes and horn strobes for ceiling applications include a variety of features that • Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela increase application flexibility and simplify installation. First,field- selectable settings,including candela,automatic selection of 12-or • Rotary switch for horn tone and three volume selections 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without • Tamper-resistant construction mounting the devices and exposing them to potential construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal Agency Listings back boxes are available separately)that accommodate in-and- out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALINGcorrosion. Plastic and metal weatherproof back boxes come with • (121 I 3A-inch top and bottom conduit entries and 3/4-inch knock-outs at the MEA back.Three screw-in NPT plugs with 0-ring gaskets for a watertight 7300-165 LISTED ® 3:187(outdoor strobes) 7125-1653.188(horn strobes, seal is included with each back box. $4011(chimes,horn strobes,horns) APPROVED approved 53593(outdoor and alert strobes) 3023572 chime strobes) MEA452-05-E 7135-1653.189(horns,chimes) SpectrAlert Advance Outdoor Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuif°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1638 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and coand UL mply with the Ameriand shall be cans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch.On four- wire products,the strobe shall be powered independently of the sounder.The horn strobe on a 2-wire model shall work on a non-coded power supply. The horn on 4-wire horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor listed per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40°F to 151°F(-40°C to 66°C) Strobe Flash Rate Nominal Voltage 1 flash per second Operating Voltage Rangel Reaulated 12 DC/FWR or regulated 24 DC/FWR1 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range with MDL3 Sync Module 8.5 to 17.5V(12 V nominal)or 16.5 to 33V(24 V nominal) Input Terminal Wire Gauge Ceiling-Mount 12 to 18 AWG g cunt Dim ensions(including lens) 6.8-diameter x 2.5"high(173 mm diameter x 64 mm high) Strobe/Horn Strobe Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Strobe/Horn Strobe Dimensions with Back Box 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Ceiling-Mount Weatherproof Back Box Dimensions 7.1"diameter x 2.0-high(180 mm diameter x 51 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS11401 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) , -' UL Max.Horn Current Draw for 4-Wire Horn Strobes(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB 8-175 Volts 16-33 Volts Standard 15 123 128 66 71 DC FWR DC FWR Candela 15/75 142 Temporal High 57 55 69 75 Range 148 77 81 Temporal Medium 44 30 NA NA 94 49 58 69 96 Temporal Low 38 44 75 NA NA 158 153 Non-Temporal Hi h 49 75 95 NA NA 9 57 56 69 75 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA Range 246 220 Coded Low 40 177 NA NA 281 251 46 52 50 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17,5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 147 79 90 115 Temporal High 1378 Temporal Medium 107 176 194 212 218 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 Non-Temporal High 141 152 91 101 121 207 85 102 163 187 207 100 116 176 201 Non-Temporal Medium 133 145 75 207 229 Non-Temporal Low 131 144 68 79 216 FWR Input 96 156 182 201 210 Temporal High 136 155 88 Temporal Medium 97 112 168 190 210 218 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 Non-Temporal High 142 86 101 160 184 194 161 103 112 126 1812019 Non-Temporal Medium 134 203 221 229 155 85 95 110 166 Non-Temporal Low 132 154 80 9 189 208 216 0 105 161 184 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) Y £ ' 202 211 16-33 Volts .��=s DC Input 135 150 177 16-33 Volts Temporal High 245 185 FWR Input 135 150 259 290 297 Temporal High 215 177 185 Temporal Medium 235 253 288 297231 258 265 Temporal Medium Temporal Low 232 251 282 209 224 250 258 292 Temporal Low Non-Temporal High 255 270 303 309233 248 248 256 Non-Temporal Medium 242 259 293 299 Non-Temporal High 233 248 275 281 Non-Temporal Low 238 Non-Temporal Medium 219 232 262 267 254 291 295 Non-Temporal Low 214 Candela Derating 229 256 262 Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn Strobe Output(dBA) candela ratings must be reduced in accordance with this table. 8-175 16-33 24-Volt Nominal Strobe Output(cd) Switch Sound Volts Volts Reverberant Anechoic Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32°F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non- High 95 70 Temporal 82 82 88 88 93 92 100 100 110 110 5 Non- Medium 115 Temporal 78 78 85 85 90 90 98 98 115 6 Non- Low 7 135 135 5 75 81 81 88 84 Temporal 96 92 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 tSettings 7, 8,and 9 are not available on 2-wire horn strobe. 96 92 AVDS11401 SpectrAlert Advance Diagrams s.a- �� �� Dia. ;:7111_=- .: „, 0 ,/,,, 2.5' C1L- ;; � �\ fi-- V Ceiling-Mount Horn Strobes Ceiling Plastic Weatherproof Back Box ,__ Ii' ,g, c `'1__ , , , I �� I j yip:.//j• '(\ r— ei / I, Ceiling-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Ceiling Horn Strobes PC2RK 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) PC2RHK 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) PC2WK 2-Wire,Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) PC2WHK 2-Wire,Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Ceiling Strobes SCRK Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SCRHK Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SCWK Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SCWHK Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Accessories SA-WBBC Red,Metal Weatherproof Back Box SA-WBBCW White,Metal Weatherproof Back Box MP120K Notes: "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing outdoor units,both the device and back box must be replaced. `�T SysTEM 3825 Ohio Avenue• SENSO/�� St.Charles, IL 60174 ©zGis System Sensor. R' Phone:800-SENSOR2•Fax:630 377-6495 Productspecficationssubjecttochangewithoutnotice.Visitsystemsensorcom for current product information,including the latest version of this data sheet. AVDS11402•02/15