Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit Support Document
P . V V I Building Permit Application - Ci ` ` 0 61/ Commercial OCT1 FOR OFFICE USE ONLY City of Tigard ` 1 o Date/B. It I Permit No.. 0 'J' V i w>A.o„"i 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Rewe f Other Permit: Phone: 503.718.2439 Fax: 503.598.196{) j ty, _ Iii,- x b Date/B Illi TIGARD Inspection Line: 503.639.4175 ,, �s}'I t Date Ready y. r frr WI See Page2 for Internet: www.tigard-or.gov Fit 11 i w iN q G £s', 1'a I N Notified/Method:!,/3 / �� Supplemental Information TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ['New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $ ❑ I-and 2-family dwelling ®Commercial/industrial 1=1 Accessory building IDMulti-familyNumber of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:6975 SW SANDBURG RD New dwelling area: square feet City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name I jk,.-i'4)„,) Covered porch area: square feet Cross street/directions to job site:From SW Dartmouth St Deck area: square feet Turn left onto SW 72nd Ave -0.8 mi Other structure area: square feet Turn left onto SW Sandburg St -0.3 mi REQUIRED DATA:COMMERCIAL-USE CHECKLIST Permit fees*are based on the value of the work performed. Subdivision: Lot no.: Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.:2S101DDOOlOI equipment,materials,labor,overhead,and the profit for the work indicated on this application. DESCRIPTION OF WORK Valuation: $15000 Replace 6 existing antennas,Add 3 RRU's w/associated cables. Existing building area: square feet New building area: square feet Number of stories: 0 PROPERTY OWNER ® TENANT Type of construction: Name:Verizon Wireless(VAW)LLC dba Verizon Wireless Occupancy groups: Address:5430 NE 122nd Ave Existing: City/State/ZIP: Portland,OR 97230 New: Phone:( ) Fax:( ) BUILDING PERMIT FEES* 0 APPLICANT ® CONTACT PERSON (Please refer to fee schedule) Business name:Black Rock Consulting Structural plan review fee(or deposit): Contact name:Brandon Clower FLS plan review fee(if applicable): Address: 1100 MELODY LANE,STE 139 Total fees due upon application: City/State/ZIP: Roseville,CA 95678 Amount received: Phone:(503)454-6622 Fax: :( ) PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* E-mail:brandon@blk-rock.com Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. CONTRACTOR Submit two(2)sets of roof plan with connection details Business name:(t.b.d.) and fire department access,along with the 2010 Oregon Solar Installation Specialty Code checklist. Address: Permit fee(includes plan review City/State/ZIP: and administrative fees): $180.00 Phone:( ) Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.: Total fee due upon application: $201.60 This permit application expires if a permit is not obtained Authorized signature: within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Print name:D Brandon Clower Date: 10/5/16 Service Board. I:\Building\Permits\BUP-COM PermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) p City of Tigard COMMUNITY DEVELOPMENT DEPARTMENT I T I GARD Building Permit Review — Commercial - N o Land Use ' 1141111111W WS Building Permit #: ,56 jP e 62.--(0)S1 Site Address: loci/5 5 W Sa"d burl s . Suite/Bldg#: v Project Name: er;- - (Name of commercial business occupying the space. If vacant,enter Spec Space.) Planning Review Proposal: ee piaci.. (o -elfi ii a K. nrt At- acid. 3 R.Rti.4 w e-1-1,A- aSsuctc cd e"idds. Existing Business Activity: b. .p,cc, /W;re.l¢..r.r Arcai {;-1- Proposed Business Activity: w /lei i rt1ess -1-it.�;l: 1 'Verify site address/suite# exists and active in permit system. 1 1 River Terrace Neighborhood: ❑ Yes % No 11. Zoning: C—P -Permitted Use: jg'Yes ❑ No ❑ Spec Space ,"Confirm no land use required. —Ste. n Gks. zia—Business License: N/Pk Exists: ❑ Yes ❑ No,applicant notified to obtain business license Notes: E)e--ervtpf- pe,— (8. -7 1 B. 03o . 13 . 1 Approved by Planning: (° h" " L 0. Ct.t.;, Date: 1 o - I I.- Ho Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Building Permit Submittal Original Submittal Date: kV/A Ay Site Plans: # Abf- Building Plans: # Building Permit#: nter building permit#above. Workflow Routing: E^r�ening L�Permit Coordinator ding Workflow Sign-off: fid' -off for Planning(include notes from planning review) Route Application Documents: 'B ding: original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: _ /C' —'� Date: id/.2..k I:\Building\Forms\BldgPermitRvw_COM_NoLandUse_070915.docx Permit Coordinator Review ❑ Conditions "Met"prior to issuance of building permit ❑ Approved, NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: ),;fgDC Fees Entered: Wash Co Trans Dev Tax: ❑ Yes h`�/A Tigard Trans SDC: ❑ Yes 'V....N/A Parks SDC: ❑ Yes a' N/A OK to Issue Permit Approved by Permit Coordinator: / Date: Wif Ji4 I:\Building\Forms\B1dgPermitRvw_COM_NoLandUse_070915.docx Dianna Howse From: Dianna Howse Sent: Thursday, August 9, 2018 6:18 PM To: 'Brandon Clower' Cc: #Building Permit Technicians;Tom Hochstatter Subject: RE: BUP2016-00289, Verizon - 6975 SW Sandburg Rd Attachments: BU P_COM_PermitApp.pdf; BUP2016-00289.pdf Hello Brandon, Per our plans examiner,Tom Hochstatter, we will need a building permit showing the restoration work to the roof top and siding where equipment was removed. The permit fees will be based on the project valuation to remove the equipment. The commercial building permit application is attached. Please complete the application and submit along with (3) sets of plans and site plan, Monday-Thursday, 8:00 am to 4:00 pm. We are closed on Fridays. As for the original permit BUP2016-00289 for replacement of antennas, we have voided this permit and there is a balance due for plan review that was completed and no fees were collected at application submittal. The total balance due is$286.20 (see at ache invoice . 1-)R-0 t/. 7 cf-- ,c These fees can be paid online at https://aca.accela.com/TIGARD/Default.aspx by searching for the permit record number BUP2016-00289 under the Building tab. Thank you and please let me know if you have further questions. Dianna L. Howse Building Division Services Supervisor City of Tigard I Community Development 13125 SW Hall Blvd I Tigard, OR 97223 503-718-2430 Direct 1503-718-2439 Permits From: Brandon Clower<brandon@blk-rock.com> Sent:Thursday,August 9, 2018 2:03 PM To:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Cc:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Subject: RE: BUP2016-00289,Verizon Hi Debbie, This project has been cancelled. Instead Verizon Wireless will be decommissioning and removing their equipment from this building. Does the City require any Building Permit for taking down their equipment? Perhaps just electrical? Any help you can provide would be greatly appreciated. Sincerely, Brandon Clower Black Rock, LLC 503-208-5319 1 BOK ROCK From: Debbie Adamski<DEBBIE@tigard-or.gov> Sent:Wednesday,June 28, 2017 2:22 PM To: Brandon Clower<brandon@blk-rock.com> Cc: #Building Permit Technicians<TigardBuildingPermits@tigard-or.Bov> Subject: RE: BUP2016-00289,Verizon Brandon, We are not automatically expiring permits at this time. So even though this permit is past the 180 days for approved plan review, it is still in ready to issue status and can be picked up once the permit fees are paid ($641.77) and the contractor is identified. If you are planning on picking up the permit in the next month or two you should be just fine. We would contact the applicant prior to actually expiring a permit. Let me know if you have any questions regarding this. Debbie Adamski Senior Building Permit Technician City of Tigard I Community Development 13125 SW Hall Blvd.,Tigard, OR 97223 503-718-2450 From: Brandon Clower [mailto:brandon@ blk-rock.com] Sent: Wednesday, June 28, 2017 11:39 AM To: Debbie Adamski Subject: BUP2016-00289, Verizon Thanks for the approval notice, Debbie! I just tried to call you this morning -but about a different project - BUP2016-00289 (changed the subject line of the email just to keep things straight). The building owner has made us wait a considerable time before we can do the work. However I expect we can begin within the next 4-6 weeks. Is our permit still active? The GC hasn't been chosen yet, but I would be happy to pay the remaining fees if necessary to keep the permit alive. Thank you. Sincerely, Brandon Clower 2 Re-- Brandon Clower 0 A. It , . , 503-203-5319 brancion@lcik-rock.com BLACK ROCK On Jun 28, 2017, at 11:02 AM, D Brandon Clower<dbrandonclower@gmail.com> wrote: Forwarded message From: Debbie Adamski<DEBBIE@tigard-or.gov> Date: Wed, Jun 28, 2017 at 10:59 AM Subject: BUP2017-00161, 16580 SW 85th Ave, Verizon To: "dbrandonclower@gmail.com" <dbrandonclower@gmail.com> Cc: #Building Permit Technicians <TigardBuildingPermits@tigard-or.gov> Brandon, This permit is ready to issue and the balance due is $578.70. You can pay the fees online at https://aca.accela.com/tigard/by searching for the permit number, or in person when you pick up the permit, Monday-Thursday, 8:00 am to 4:30 pm. We are closed on Friday. We also will need the contractor identified prior to issuance. Thanks. Debbie Adamski Senior Building Permit Technician City of Tigard I Community Development 13125 SW Hall Blvd., Tigard, OR 97223 503-718-2450 DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E-mails are retained by the City of Tigard in compliance with the Oregon Administrative Rules"City General Records Retention Schedule." 3 b ki` r) I Fru MORRISON HERSHFIELD OCT .„, J 1' ;TIEA1) STRUCTURAL CALCULATION �[1[1a 'GDIVIS N FOR ANTENNA MOUNTS Site Name: POR Tualatin Site Address: 6975 SW Sandburg Street Tigard, OR 97223 Project Number: 7160045 Date: September 19, 2016 Morrison Hershfield Corporation ` 2 South University Drive, Suite 245 Plantation, FL 33324 (954)577-4655/Phone (954)577-4656/Fax CITY OF TIGARD RT VIEWED FOR CO E COMPLIANCE Approved: [ OTC: [ I Pcrrnit #: '-05 4-404 Address: Art -`--1 -w-.,, .11ibrtiA,1-11° Suite •• .cocruR. Date: art 9EO PROFF� By: �/ kn ,,� Sts, 4.,\ � Z z 88148PE --- OFFICE COPY " _G( 7 Yan Wang, P.E. V‘ OR License No. 88148PE �'.,��• G Senior Engineer Se• '9 p,Nan P EXPIRES:6/30/201.8 2 South University Drive, Suite 245, Plantation, FL 33324 Ph: (954)577-4655 Fax (954)577-4656 ■ MORRISON HERSHFIELD Project#: 7160045 Date: 09/19/2016 Site: POR Tualatin By: YW DESIGN CRITERIA REFERENCES 2014 Oregon Structural Specialty Code ASCE 7-10 Minimum Design Loads for Building and Other Structures ANSI/TIA-222-G, Structural Standard for Antenna Supporting Structures and Antennas AISC Steel Construction Manual, 141h Edition Structural calculation report#10010.244 by CG Engineering dated May 2010 DESIGN DATA Wind Load 120 mph (ASCE 7-10, ultimate 3-second gust) 93 mph (TIA-222-G, equivalent nominal 3-second gust) Exposure = "C" Risk Category = II Seismic Load SS = 0.975 Si = 0.422 Site Class = "D" Risk Category = II Importance Factor= 1.00 Antenna Loads Proposed Antennas: (6) Commscope SBNHH-1 D45C 95.9"x18.0"x7.0", 79.6 lbs (9) RRU-A2 16.4"x15.1"x3.4", 22 lbs (2) Raycap RCMDC-3315-PF-48 19.18"x15.73"x10.25", 26.9 lbs Existing Antennas: (3) CSS X7CAP-480 50.5"x14.6"x7.8", 30 lbs 1 Er • MORRISON HERSHFIELD Project#: 7160045 Date: 09/19/2016 Site: POR Tualatin By:YW WIND LOAD CALCULATION Code: I International Building Code 2012 w• Occupancy: Occupancy Group= B I Business Risk Category& Importance Factors: Risk Category {Category 11:All bldgs and other structures except those listed in Categories L UI,&IV w l Wind factor= 1.00 use 0.60 NOTE: Output will be nominal wind pressures Snow factor= 1.00 Seismic factor= 1.00 Building Geometry: Roof angle (6) ' 0.00/ 12 0.0 deg Building length(L) ' 107.0 ft Least width (B) ' 107.0 ft Mean Roof Ht (h) ' 35.0 ft Parapet ht above grd ' 37 0 ft Minimum parapet ht ' 2.0 ft - Wind Loads : ASCE 7-10 Ultimate Wind Speed' 120 mph Nominal Wind Speed 93 mph Risk Category II Exposure Category ` C Exposure C IL!I Enclosure Classif. Enclosed Buildinc Enclosed Building w Internal pressure +/-0.18 Directionality (Kd) 0.85 I ASCE?Load Combinations Used I.I Kh case 1 ., 1.015 Kh case 2 1.015 I Type of roof Monoslope I Monoslope iv V(z) 2' ; �y-Speed-up Topographic Factor (Kzt) V(z) xiupanrd] x(downvandJ Topography Flat I Ftat .----- Hill Height (H) 0.0 ft H< 1�ft;exp C ` H/2 Half Hill Length(Lh) 0.0 ft :. Kzt=1.0 ,`- Lh H I-1/2Actual H/Lh = 0.00 Use H/Lh 0.00 Modified Lh = 0.0 ft ESCARPMENT From top of crest:x=' 0.0 ft Bldg up/down wind? downwind (downwind),I V(Z) H/Lh= 0.00 K1= 0.000 -1Speedup x/Lh= 0.00 K2= 0.000 x(upwind) ' x(downwind) iiii z/Lh= 0.00 K3= 1.000 4-- .� H At Mean Roof Ht: "Lh H/2 Kzt=(1+K1K2K3)"2= 1.00 2D RIDGE or 3D AXISYMMETRICAL HILL 2 lir a MORRISON HERSHFIELD Project#: 7160045 Date: 09/19/2016 Site: POR Tualatin By: YW Design Wind Pressure Rooftop Structures&Equipment#1 Equipment length parallel to L= 1.5 ft Equipment length parallel to B= 1.5 ft Height of equipment = 4.0 ft Base pressure(qh)= 19.1 psf Vertical wind pressure Wind normal to building B Wind normal to building L Ar= 2.3 sf Af = 6.0 sf Af = 6.0 sf GCr= 1.500 GCr= 1.90 GCr= 1.90 F=qhGCr Ar= 28.6 Ar(psf) F=qhGCr Af= 36.2 Af(psf) F=qhGCr Af= 36.2 Af(psf) Wind loads: On proposed antenna 36.2x95.9x18/144 =434 lbs (front) 36.2x95.9x7/144 = 169 lbs (side) On existing antenna 36.2x50.5x14.6/144 = 185 lbs (front) 36.2x50.5x7.8/144 = 99 lbs (side) On existing 2" pipe 36.2x2.375/12 = 7.2 plf On new 2.5" pipe 36.2x2.875/12 = 8.7 plf On existing L2x2 angle 36.2x2/12 = 6 plf 3 ■ MORRISON HERSHFIELD Project#: 7160045 Date: 09/19/2016 Site: POR Tualatin By:YW SEISMIC CALCULATION Seismic Loads: IBC 2012 Strength Level Forces Risk Category: II Importance Factor(I): 1.00 Site Class: D I Class 0 IL Ss(0.2 sec)= 97.50%g1 S1 (1.0 sec)= 42 20%g.' Fa= 1.110 Sms= 1.082 SDs= 0.722 Design Category= D Fv= 1.578 Sm1 = 0.666 501= 0.444 Design Category= D Seismic Design Category= D I n Check to use SDC D as a minimum MECH AND ELEC COMPONENTS SEISMIC COEFFICIENTS Seismic Design Category D&Ip=1.0,therefore see ASCE?Section 13.1.4 for exceptions Mech or Electrical Component: other mechanical or electrical components. V Importance Factor(Ip): [Ip=to all other components Component Amplification Factor(an)= 1 h= 35.0 feet Comp Response Modification Factor(Rn)= 1.5 z= 39.0 feet z/h= 1.00 Fp=0.4apSdslpWp(1+2z/h)/Rp= 0.577 Wp not greater than Fp= 1.6SdslpWp= 1.154 Wp but not less than Fp=0.3SdslpWp= 0.216 Wp use Fp= 0.577 Wp Seismic loads: On proposed antenna = 0.7x0.577x79.6 = 32 lbs <434 lbs On existing antenna= 0.7x0.577x30 = 12 lbs < 185 lbs Seismic loads are less than wind load. Therefore, wind load governs the mount design. 4 ■ p ■ MORRISON HERSHFIELD Project#: 7160045 Date: 09/19/2016 Site: POR Tualatin By: YW MOUNT ANALYSIS The modified antenna mounting frame is analyzed using STAAD Pro. Refer to enclosed printouts for calculation details. PEW 2'/T STO PGE.l0'-6-LONG TOT 2 e 12-STO PIPE.17-6'LONG ® C61S1MMFRWE:MOUNT � NN_ Sl l PEW 2 I/2-S10 PIPES NEW 2 1/2'510 Nets Sit t amreuG ROOF__.. ! I 1 1_ Dead Loads: Proposed antenna w/ mount= 100 lbs Existing antenna w/ mount= 50 lbs Wind loads: See wind load calculations. The modified mounting frame is calculated to be sufficient for the proposed loading. Check existing roof, Consider roof design loads: DL = 15 psf SL = 25 psf Per roof framing plan contained in the referenced CG Engineering structural report, the existing roof is constructed using 2x12 #2DF joists at 24" O.C. w/ min fb = 1450 psi. 5 ■ r ■ MORRISON HERSHFIELD Project#: 7160045 Date: 09/19/2016 Site: POR Tualatin By:YW Roof joist is analyzed using ENERCALC. Refer to enclosed printouts for calculation details. Roof joist is calculated to be sufficient for the revised loading. Conclusion: The modified antenna supporting frame and the existing roof joists are calculated to be sufficient for the proposed antenna loads. 6 Morrison Hershfield Corporation Job No Sheet No Rev F03. 2 Snty 7160045 1 PlantationouthU,FLiversi33324 Drive#245 Software licensed to Part Job Title POR Tualatin Ref By Date19-Sept-16 Chd Client Verizon File antenna mount_3_mod.st Date/Time 19-Sep-2016 14:17 Job Information Engineer Checked Approved Name: Date: 19-Sept-16 Structure Type SPACE FRAME Number of Nodes 24 Highest Node 24 Number of Elements 31 Highest Beam 31 Number of Basic Load Cases 3 Number of Combination Load Cases 2 Included in this rintout are data for: I All I The Whole Structure I Included in this printout are results for load cases: Type UC Name Primary 1 DL - Primary 2 WLX Primary 3 WLZ Combination 4 DL+WLX Combination 5 DL+WLZ ii r , Pr. ic II, Aiikw op. -Nov X r Z 3D Rendered View pApp—'Morrison Hershfield Corporation Job No Sheet No Rev 2 South University Drive#245 7160045 2 Plantation,FL 33324 Software licensed to Part Job Title FOR Tualatin Ref By Date19-Sept-16 Chd Client Verizon File antenna mount_3_mod.st Date/lime 19-Sep-2016 14:17 4 /ISI s 9 101 5 20 3 Load 6 Model Nodes t n 0 x 1° I 18 x _ ; 13 u xsd A Load 6 Model Beams Mr"`" Morrison Hershfield Corporation Job No Sheet No Rev 2 South University Drive#245 7160045 3 V Plantation,FL 33324 +41110 Software licensed to Part Job Title POR Tualatin Ref By DatE19-Sept-16 Chd Client Verizon File antenna mount_3_mod.st Date/Time 19-Sep-2016 14:17 100 lb .lb 100 lb 00 1111141O,'41111111 1 8 i Load 1 • Model Loads:DL r leg NO ii r 169 lb r fill 981 rill r ,r. Tal R r 00 ZilleriAlk 169lb OA TO i1 NO % AMM s _ r i / 6.7IbnR 7.2_/ft M IL '73 ,b la IP ir1. M 7 /ft Ilk IP MM MM ila Load 2 Model Loads:WLX Morrison Hershfield Corporation Job No Sheet No Rev 2 South University Drive#245 7160045 4 - Plantation,FL 33324 Part Software licensed to Job Title POR Tualatin Ref By Date19-Sept-16 Chd Client Verizon File antenna mount_3_mod.st Date/rime 19-Sep-2016 14:17 lb -lb ,,, IbIllt 11. :IS lb 0 ...log- ‘ �wwww Ib/M Ibttfl is _ ��= �\ \ IbitIt \ \ • lc. \ 2 \ Load S - Model Loads.WLZ Section Properties Prop Section Area lyy lzz J Material (in2) (in4) (in4) (in4) 1 PIPS25 1.590 1.450 1.450 2.891 STEEL 2 PIPS20 1.000 0.627 0.627 1.254 STEEL 3 L20204 0.938 0.552 0.144 0.020 STEEL Basic Load Cases Number Name 1 DL 2 WLX 3 WLZ Combination Load Cases Comb. Combination L/C Name Primary Primary L/C Name Factor - 4 DL+WLX 1 DL 1.00 2 WLX 1.00 5 DL+WLZ 1 DL 1.00 - 3 WLZ 1.00 1 Morrison Hershfield Corporation Job No Sheet No Rev At2 South University Drive#245 7160045 5 Plantation,FL 33324 Software licensed to Part Job Title POR Tualatin Ref By Date19-Sept-16 Chd Client Verizon File antenna mount_3_mod.st Datelrime 19-Sep-2016 14:17 Node Displacement Summary Node LIC X Y Z Resultant rX rY rZ (in) (in) (in) (in) (rad) (rad) (rad) Max X 23 4:DL+WLX 0.108 -0.019 0.001 0.110 0.000 0.000 -0.001 Min X 6 5:DL+WLZ -0.008 0.000 0.540 0.540 0.012 0.005 0.000 Max Y 21 2:WLX 0.034 0.008 -0.001 0.035 -0.000 -0.000 -0.000 Min Y 23 4:DL+WLX 0.108 -0.019 0.001 0.110 0.000 0.000 -0.001 Max Z 24 3:WLZ 0.000 0.000 1.163 1.163 0.013 0.003 -0.000 Min Z 14 5:DL+WLZ -0.001 0.000 -0.032 0.032 -0.002 -0.000 -0.000 Max rX 5 3:WLZ -0.000 0.001 0.849 0.849 0.021 0.000 0.000 Min rX 2 5:DL+WLZ 0.000 0.000 0.000 0.000 -0.003 -0.000 0.000 Max rY 6 3:WLZ -0.001 0.001 0.541 0.541 0.012 0.005 0.000 Min rY 4 5:DL+WLZ 0.008 0.000 0.540 0.540 0.012 -0.005 -0.000 Max rZ 10 3:WLZ 0.000 0.000 0.000 0.000 0.001 -0.001 0.002 Min rZ 5 2:W1JX 0.075 -0.000 -0.000 0.075 -0.000 0.000 -0.002 Max Rst 24 3:WLZ 0.000 0.000 1.163 1.163 0.013 0.003 -0.000 Beam End Force Summary The signs of the forces at end B of each beam have been reversed.For example:this means that the Min Fx entry gives the largest tension value for an beam. Axial Shear Torsion Bending Beam Node LIC Fx Fy Fz Mx My Mz (Ib) (Ib) (Ib) (lb-ft) (Ib-ft) (Ib-ft) Max Fx 10 11 5:DL+WLZ 1424 -2 2 -0 -0 -0 Min Fx 15 14 3:WLZ -756 2 423 -0 -156 3 Max Fy 6 9 4:DL+WLX 213 244 1 3 -3 214 Min Fy 27 18 4:DL+WLX 215 -199 -1 -0 -3 274 Max Fz 15 8 5:DL+WLZ -575 2 445 -0 1147 -3 Min Fz 5 8 5:DL+WLZ 149 -2 -629 0 1148 -3 Max Mx 28 22 3:WLZ 2 3 -37 314 -8 -0 Min Mx 22 13 3:WLZ 30 -1 14 -314 -76 -2 Max My _ 5 8 5:DL+WLZ 149 -2 -629 0 1148 -3 Min My 20 19 5:DL+WLZ 28 55 -316 5 -754 -104 Max Mz 24 17 4:DL+WLX 100 -116 -2 1 -7 289 Min Mz 6 18 4:DL+WLX 206 230 1 3 -0 -260 Morrison Hershfield Corporation Job No Sheet No Rev 2 South University Drive#245 7160045 6 Plantation,FL 33324 Part _, Software licensed to Job Title POR Tualatin Ref By DatEl9-Sept-16 Chd Client Verizon File antenna mount_3_mod.st Date/Time 19-Sep-2016 14:17 Reaction Summary Horizontal Vertical Horizontal Moment Node UC FX FY FZ MX MY MZ (lb) (Ib) (Ib) (lb-ft) (lb-ft) (Ib-ft) Max FX 1 4:DL+WLX 99 -106 0 0 0 0 Min FX 2 4:DL+WLX -958 310 -1 0 0 0 Max FY 11 5:DL+WLZ 0 792 -1183 0 0 0 Min FY 2 3:WLZ -20 -799 214 0 0 0 Max FZ 3 5:DL+WLZ -64 -220 254 0 0 0 Min FZ 11 5:DL+WLZ 0 792 -1183 0 0 0 Max MX 1 1:DL 70 222 -0 0 0 0 Min MX 1 1:DL 70 222 -0 0 0 0 Max MY 1 1:DL 70 222 -0 0 0 0 Min MY 1 1:DL 70 222 -0 0 0 0 Max MZ 1 1:DL 70 222 -0 0 0 0 Min MZ 1 1:DL 70 222 -0 0 0 0 Utilization Ratio Beam Analysis Design Actual Allowablel Ratio Clause LIC Ax lz ly lx Property Property Ratio Ratio (Act./Allow.) (in2) (in") (in°) (in") 1 PIPS20 PIPS20 0.280 1.000 0.280 1.000 0.627 0.627 1.254 2 PIPS20 PIPS20 0.191 1.000 0.191 1.000 0.627 0.627 1.254 3 PIPS20 PIPS20 0.264 1.000 0.264 1.000 0.627 0.627 1.254 4 PIPS20 PIPS20 0.610 1.000 0.610 1.000 0.627 0.627 1.254 5 PIPS20 PIPS20 0.928 1.000 0.928 1.000 0.627 0.627 1.254 6 PIPS20 PIPS20 0.609 1.000 0.609 1.000 0.627 0.627 1.254 7 L20204 L20204 0.251 1.000 0.251 0.938 0.143 0.552 0.020 8 L20204 L20204 0.247 1.000 0.247 0.938 0.143 0.552 0.020 9 L20204 L20204 0.311 1.000 0.311 0.938 0.143 0.552 0.020 10 L20204 L20204 0.520 1.000 0.520 0.938 0.143 0.552 0.020 11 L20204 L20204 0.311 1.000 0.311 0.938 0.143 0.552 0.020 12 L20204 L20204 0.318 1.000 0.318 0.938 0.143 0.552 0.020 13 L20204 L20204 0.184 1.000 0.184 0.938 0.143 0.552 0.020 14 PIPS20 PIPS20 0.611 1.000 0.611 1.000 0.627 0.627 1.254 15 PIPS20 PIPS20 0.941 1.000 0.941 1.000 0.627 0.627 1.254 16 PIPS20 PIPS20 0.602 1.000 0.602 1.000 0.627 0.627 1.254 17 PIPS20 PIPS20 0.012 1.000 0.012 1.000 0.627 0.627 1.254 18 PIPS20 PIPS20 0.299 1.000 0.299 1.000 0.627 0.627 1.254 19 PIPS20 PIPS20 0.012 1.000 0.012 1.000 0.627 0.627 1.254 20 PIPS25 PIPS25 0.359 1.000 0.359 1.590 1.450 1.450 2.900 21 PIPS25 PIPS25 0.300 1.000 0.300 1.590 1.450 1.450 2.900 22 PIPS25 PIPS25 0.140 1.000 0.140 1.590 1.450 1.450 2.900 23 PIPS25 PIPS25 0.089 1.000 0.089 1.590 1.450 1.450 2.900 24 PIPS25 PIPS25 0.300 1.000 0.300 1.590 1.450 1.450 2.900 25 PIPS25 PIPS25 0.091 1.000 0.091 1.590 1.450 1.450 2.900 26 PIPS25 PIPS25 0.300 1.000 0.300 1.590 1.450 1.450 2.900 27 PIPS25 PIPS25 0.360 1.000 0.360 1.590 1.450 1.450 2.900 28 PIPS25 PIPS25 0.140 1.000 0.140 1.590 1.450 1.450 2.900 Ito 'Morrison Hershfield Corporation Job No Sheet No Rev 73 2 South University Drive#245 7160045 7 Plantation,FL 33324 Software licensed to Part Job Title POR Tualatin Ref By Date19-Sept-16 Chd Client Verizon File antenna mount_3_mod.st Date/Time 19-Sep-2016 14:17 Utilization Ratio Cont... Beam Analysis Design Actual Allowabll Ratio Clause L/C Ax lz ly ' lx Property Property Ratio Ratio (Act./Allow.) (int) (in4) (in4) (in4) 29 PIPS25 PIPS25 0.301 1.000 0.301 1.590 1.450 1.450 2.900 30 PIPS25 PIPS25 0.184 1.000 0.184 1.590 1.450 1.450 2.900 31 PIPS25 PIPS25 0.184 1.000 0.184 1.590 1.450 1.450 2.900 Failed Members There is no data of this type. Morrison Hershfield Corporation Project Title: POR Tualatin ' 2 South University Drive,Suite 245pip Engineer: Project ID: 7160045 Plantation,Florida 33324 Project Descr: (954)577-4655 Ph. (954)577-4656 Fax www.morrisonhershfield.com Printed,19 SEP 2016,234PM File=V:\ ject1716 Series171600451sites\POR Tualatin\Structurallroof check.ec6 • W d Beam ENERCALC,INC.1983-2016,Build:6.16.6.7,Ver:6.16.6.7 Lic.#':KW-06004028 Licensee:morrison hershfield corporation Description: Existing 2x12 Roof Joists(revised mount) CODE REFERENCES Calculations per NDS 2012, IBC 2012, CBC 2013,ASCE 7-10 Load Combination Set:ASCE 7-05 Material Properties Analysis Method: Allowable Stress Design Fb-Tension 1,500.0 psi E:Modulus of Elasticity Load Combination ASCE 7-05 Fb-Compr 1,500.0 psi Ebend-xx 1,600.0 ksi Fc-Prll 1,150.0 psi Eminbend-xx 580.0ksi Wood Species : Douglas Fir-Larch(North) Fc-Perp 625.0 psi Wood Grade :Select structural Fv 170.0 psi Ft 1,000.0 psi Density 30.580pcf Beam Bracing : Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase D(0.311)W(-0.799) D(0.011)W(0.781) . . i 0(0.03�S(0.05) M 1111111 N 7 2x12 Span=17.540 ft i Applied Loads Service loads entered.Load Factors will be applied for calculations. Beam self weight calculated and added to loads Uniform Load: D=0.030, S=0.050, Tributary Width=1.0 fl Point Load: D=0.3110, W=-0.7990 k @ 1.667 ft Point Load: D=0.0110, W=0.7810 k @ 7.667 fl DESIGN SUMMARY Design OK Maximum Bending Stress Ratio = 0.686 1 Maximum Shear Stress Ratio = 0.430 : 1 Section used for this span 2x12 Section used for this span 2x12 fb:Actual = 1,893.63psi fv:Actual = 84.07 psi FB:Allowable = 2,760.O0psi Fv:Allowable = 195.50 psi Load Combination 4D+0.750L+0.750S+0.750W+H Load Combination +D+S+H Location of maximum on span = 7.682ft Location of maximum on span = 0.000 ft Span#where maximum occurs = Span#1 Span#where maximum occurs = Span#1 Maximum Deflection Max Downward Transient Deflection 0.376 in Ratio= 559>=360 Max Upward Transient Deflection 0.000 in Ratio= 0<360 Max Downward Total Deflection 0.879 in Ratio= 239>=180 Max Upward Total Deflection 0.000 in Ratio= 0<180 Maximum Forces &Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span# M V Cd C FN C i Cr C m C t C L M ib F'b V Iv F'v D Only 0.00 0.00 0.00 0.00 Length=17.540 ft 1 0.393 0.321 0.90 1.000 1.00 1.15 1.00 1.00 1.00 1.61 610.79 1552.50 0.55 49.07 153.00 +0+1+1-I 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 • Length=17.540 ft 1 0.354 0.289 1.00 1.000 1.00 1.15 1.00 1.00 1.00 1.61 610.79 1725.00 0.55 49.07 170.00 +D+Lr+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=17.540 ft 1 0.283 0.231 1.25 1.000 1.00 1.15 1.00 1.00 1.00 1.61 610.79 2156.25 0.55 49.07 212.50 +D+S+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=17.540 ft 1 0.673 0.430 1.15 1.000 1.00 1.15 1.00 1.00 1.00 3.52 1,336.04 1983.75 0.95 84.07 195.50 +D+0.750Lr+0.750L+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Morrison Hershfield Corporation Project Title: POR Tualatin II 2 South University Drive,Suite 245 Engineer: Project ID: 7160045 Plantation,Florida 33324 Project Descr: (954)577-4655 Ph. (954)577-4656 Fax www.morrisonhershfield.com Prlrted.19 SEP 2016.2 34P File=V:Iproject1716 Series171600451sites\POR Tualatin\Structural\roof check.ec6 • Wood Beam ENERCALC,INC.1983-2016,Build:6.16.6.7,Ver:6.16.6.7 _ Lic.#:KW-06004028 Licensee':morrison hershfield corporation Description: Existing 2x12 Roof Joists(revised mount) Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span# M V Cd CFN Ci Cr Cm C t CL M fb Pb V fv Fv Length=17.540 ft 1 0.283 0.231 1.25 1.000 1.00 1.15 1.00 1.00 1.00 1.61 610.79 2156.25 0.55 49.07 212.50 +D+0.750L+0.750S+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=17.540 ft 1 0.582 0.385 1.15 1.000 1.00 1.15 1.00 1.00 1.00 3.04 1,154.19 1983.75 0.85 75.32 195.50 -*D+W+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=17.540 ft 1 0.581 0.238 1.60 1.000 1.00 1.15 1.00 1.00 1.00 4.23 1,603.23 2760.00 0.73 64.77 272.00 +D+0.70E+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=17.540 ft 1 0.221 0.180 1.60 1.000 1.00 1.15 1.00 1.00 1.00 1.61 610.79 2760.00 0.55 49.07 272.00 +D+0.750Lr+0.750L+0.750W+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=17.540 ft 1 0.491 0.196 1.60 1.000 1.00 1.15 1.00 1.00 1.00 3.57 1,355.12 2760.00 0.60 53.31 272.00 +D+0.750L+0.750S+0.750W+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=17.540 ft 1 0.686 0.282 1.60 1.000 1.00 1.15 1.00 1.00 1.00 4.99 1,893.63 2760.00 0.86 76.79 272.00 +D+0.750Lr+0.750L+0.5250E+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=17.540 ft 1 0.221 0.180 1.60 1.000 1.00 1.15 1.00 1.00 1.00 1.61 610.79 2760.00 0.55 49.07 272.00 +D+0.750L+0.750S+0.5250E+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1 Length=17.540 ft 1 0.418 0.277 1.60 1.000 1.00 1.15 1.00 1.00 1.00 3.04 1,154.19 2760.00 0.85 75.32 272.00 +0.60D+W4l 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=17.540 ft 1 0.492 0.210 1.60 1.000 1.00 1.15 1.00 1.00 1.00 3.58 1,358.93 2760.00 0.64 57.19 272.00 +0.60D+0.70E+H 1.000 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=17.540 ft 1 0.133 0.108 1.60 1.000 1.00 1.15 1.00 1.00 1.00 0.97 366.47 2760.00 0.33 29.44 272.00 Overall Maximum Deflections Load Combination Span Max."-"Defl Location in Span Load Combination Max."+"Defl Location in Span +D+0.750L+0.750S+0.750W+H 1 0.8791 8.706 0.0000 0.000 5,1 3,8 u. ][ v Liz Ce Co �. Z 13 111111111111111111111441%11\ MEMBER•••>> 166 3,39 5.12 6,85 858 1031 12.03 1316 15,49 1722 Distance(ft) I DOnly I+D+t+H I+D+LI+H I+D+S+H I+D+D.7SD1'+D.ISDL+H I+D+D.ISDL+D.ISDS+H I+D+W+H I+D+D.IDE+H I+D+D.ISDL1+D.ISDL+D,ISDW+H I+D+6.ISDL+D.ISDS+D.ISDW+H I+D+DISDLI+D.I56L+D,SZSDE+HI+D+D.ISDL+DISDS+D.SZSDE+ I+D.6DD+W+H I+0,6DD+6.IDE+H Morrison Hershfield Corporation Project Title: POR Tualatin . 2 South University Drive,Suite 245pi Engineer: Project ID: 7160045 Plantation,Florida 33324 Project Descr: (954)577-4655 Ph. (954)577-4656 Fax www.morrisonhershfield.com Printed:19 SEP 2016,2:34PM Wood Beam File=V:lproject1716 Series171600451sites\POR Tualatin\Structural\roof check.ec6 ENERCALC,INC.1983-2016,Build:6.16.6.7,Ver:6.16.6.7 Lic.#:KW-06004028 Licensee:morrison hershfield corporation Description: Existing 2x12 Roof Joists(revised mount) 10 11•1 _ y pp��11 ,. L MEMBER-»44* —..I 0 - 0 •09 . 166 339 5,12 6.85 858 1031 1253 13,16 15,49 1122 Distance(ft) I DO®ly I+D+t+H I+D+U+H I+D+S+H I+D+D,ISDLi+6.7SDL+H I+D+6,7SDL+D.7SDS+H I+D+W+H I+D+D,7DE+H I+D+D.7SDLI+D.75DL+D.7SDW+H I+D+D,7SDL+61SDS+D.7SDW+H I+D+D.7SDL1+6,7SDL+D,SZSDE+11 I+D+D.ISDL+6.7SDS+D3ZSDE+ - I+0.60D+W+H I+6.66D+D.7DE+11 MEMBER 0.22 Ste ,.. ,,;. - : .0,45 - y :: z...--- 0 i rr �vf$ffR. mo, 0 .0,67 . " • •0,90 126 339 512 6.85 858 1031 12.03 13.76 1549 1122 Distance(ft) I Doily I+D+L+H I+D+L+H I+D+S+H I+D+6.7S6L'+D.ISDL+H I+6+D.75DL+D.7SDS+H I+D+W+H I+D+D.76E+H I+D+DISD11+6,7SDL+DISDW+H I+D+D.7SDL+0.1SDS+D.I5IW+H I+D+6.ISDLAD.7SDL+D.SZSDE+11 I+D+6.7S6t+D.7SDS+D.SZSDE+ I+6,66D+W+H I+6.EDD+D.7DE+H I DOnly LiOely I LOnly I SOnly • III/Only I EOnly I HOnly DO NOT SCALE PRAWINGS.CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OMISSIONS.NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS At, SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON 'U 7 Y r HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIEI NOR THE ARCHITECT WILL BE PROVIDING CONSTRUCTION • ■ It gg�1' REVIEW OF THIS PROJECT. littj Ai ��RE.D ARc,, , verizony OCT 1 2016 Ca, ROB ERT J. �� 1 �� 1 .. T Z } License A RA897 �� 1 #5 BUILDING DIVISION I'D LANTA,IION, ; 1. • POR TUALATIN Sep �h2o�6�F �:��� PROJECT NAME: O V ROBERT JERRY LARA REGISTERED ARCHITECT STATE OF OREGON PROJECT LOCATION: 6975 SW SANDBURG ST 5897 TIGARD, OR 97223 CONSTRUCTION _ _ i 1 0 09/19/16 ISSUED FOR CONSTRUCTIC 1 4 C 09/08/16 ISSUED FOR REVIEW B 06/27/16 ISSUED FOR REVIEW VICINITY MAP PROJECT INFORMATION SCOPE OF WORK A 05/18/16 ISSUED FOR REVIEW 9. MY W,IV A' LS c,ry,.•0 FT JURISDICTION: CITY OF TIGARD VERIZON WIRELESS PROPOSES TO MODIFY AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY. No. Date Revision THE PROPOSAL CONSISTS OF THE REMOVAL OF (2) RAYCAP SURGE SUPPRESSORS & (3) RRU; Client: PARCEL ID: W262492 REPLACEMENT OF (6) EXISTING PANEL ANTENNAS: AND THE ADDITION OF (6) RRU-A2 AND (3) $" a Eli S..{ni�s� ZONING CLASS: CP (PROFESSIONAL COMMERCIAL) RAYCAP SPLITTER/SURGE SUPPRESSOR ON AN EXISTING ROOFTOP MOUNT. VERIZON WIRELESS ALSO < x ;"`-; e - ry 8*OAB I Ir PROPOSES THE ADDITION OF (2) HYBRID CABLES AND (3) RAYCAP SURGE SUPPRESSORS INSTALLED TIN Wet i f o OCCUPANCY GROUP: UTILITY INSIDE AN EXISTING EQUIPMENT ROOM WITHIN AN EXISTING BUILDING. ■ . a. I -97f+OTF.,4„ {,, � ,r CONSTRUCTION TYPE: 2N verizon 'i ''�. o- ^ 00,00.10 1+ MAP TAX LOT: 25101DD00101 a 0a. a ,3 BW 00.1.01d LATITUDE: 45'25'17.76" N „ N .ytr. P sat X4.4 mow c 45.4216' `„ "',_ g E R,rn•Fna LONGITUDE: 122'44'50.75" W . ' .'nelr,a. a a 122.747431' Implementation Team: S �ArT4.d LIST OF DRAWINGS 'ta a GROUND ELEVATION: 230' AMSL s • :xes; ';L q w il. STRUCTURE HEIGHT: 37'-0" (TOP OF BUILDING) SHEET DESCRIPTION .Y A4., VW su,U'WW S 6TUBWme ar 47'-0" (TOP OF EXISTING PANEL ANTENNAS OF. OTHERS) T-1 COVER SHEET \., 8 43' 0" (TOP OF PROPOSED VERIZON WIRELES'.PANEL ANTENNAS) )e0 "4 Yea L' ,ere,• \ t At- B i ; A-1 SITE PLAN10, ) ro "yr t` s A-1.1 PROPOSED ROOF PLAN � � ;4 s� I'- A-2 EXISTING AND PROPOSED BUILDING PROFILES BLACK ROCK q A-3 CONSTRUCTION DETAILS A&E Team: *P.'+ SmlthOood II ir'gte-T { ow P•rk A-4 CONSTRUCTION DETAILS 'Wing zn w0..s2 = I �'� RF-1 ANTENNA CONFIGURATIONS 4 srReiPm t'`'% kt S-i DETAILS MORRISON HERSHFIELD bgrtl Kat L6'eli„ a 3 ` G-1 GROUNDING DETAILS 600 STEWART ST,SUITE 200 0*(000051 t SEATTLE,WA 98101 Q+sOrR R TeI:205.268.7370 svd `S 3 www.morrisonhershfield.Gom is 4 A Project Info: ir sw TwcAMMv-'. 'G;� r a PROJECT„' II ,,A' POR `®`M`�°"aTa `"� SITE TUALATIN M•S m rr Rd ,l 6975 SW SANDBURG STREET sLxryB ., - = TIGARD, OR 97223 DRIVING DIRECTIONS CONTACTS CODE COMPLIANCE Drawing Title: (FROM SEATTLE, WA): JMPLEMENTATION CONTACT. APPLICANT CONTACT. ME CONTACT. ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT TOM WALL BRANDON CLOWER ROY LORETE CONDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING COVER • SOUTHBOUND ON I-5 TOWARD PORTLAND VERIZON WIRELESS (VAW) LLC BLACKROCK CONSULTING LLC MORRISON HERSHFIELD CORP IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: • ENTERING OREGON (d/b/a VERIZON WIRELESS) 1100 MELODY LANE, SUITE 139 600 STEWART ST, SUITE 200 SHEET • AT EXIT 303, TAKE RAMP RIGHT FOR ALBERTA ST. TOWARD SWAN ISLAND 185 MAPLE ST ROSEVILLE, CA 95678 SEATTLE, WA 98101 OREGON STATE AND LOCAL BUILDING CODES WITH THE FOLLOWING REFERENCE CODE: • TURN LEFT ONTO N ALBERTA ST EUGENE, OR 97402 PHONE: (503) 208-5319 PHONE : (206) 268-7370 2014 OREGON STRUCTURAL SPECIALTY CODE • TURN RIGHT ONTO N VANCOUVER AVE PHONE: (541) 401-0001 brandon®blk-rock.Com rlorete®morrisonhershfield.com 2014 NATIONAL ELECTRICAL CODE ` • TURN RIGHT ONTO N COOK ST 2014 OREGON MECHANICAL SPECIALTY CODE j • TAKE RAMP RIGHT FOR 1-405 S TOWARD FREMONT BR. 2012 NFPA 101 LIFE SAFETY CODE Project Number: Start Date: i • KEEP LEFT TOWARD 1-5 S 1 •▪ AT EXIT 292, TAKE RAMP RIGHT FOR OR-217 TOWARD TIGARD / BEAVERTON PROPERTY OWNER CONTACT. PROFESSIONAL OF RECORD: • TURN RIGHT ONTO OR-217 N WESTON HOLDING CO. LLC YAN WANG ROBERT J LARA Drafter: Designer: C\0 AMERICAN PROPERTY MANAGEMENT MORRISON HERSHFIELD CORP MORRISON HERSHFIELD CORP • AT EXIT 7, TAKE RAMP RIGHT AND FOLLOW SIGNS FOR 72ND AVE. PHONE: (50.3) NE9545774668 281-7779 PHONE: (954) 577-4668 PHO : ( ) - LW SV • TURN LEFT ONTO SW 72ND AVE ywang@morrisonhershfield.com rlaro©morrisonhershfield.Com SIGNATURE APPROVALS DATE Project Manager: Professional of Record'1 r • TURN LEFT ONTO SW SANDBURG ST -• SITE IS STRAIGHT AHEAD RKL RL i REPRESENTATIVE Revision No: Sheet No: k SITE OWNER . T- 1 RF ENGINEER 1 GENERAL NOTES LINE/ANTENNA NOTES ABBREVIATIONS DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS.NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL.ALL PREVIOUS ISSUES OF THIS DRAWING ARE 1. WORK SHALL COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. ALL NECESSARY LICENSES, 1. ALL THREADED STRUCTURAL FASTENERS FOR ANTENNA SUPPORT ASSEMBLES SHALL CONFORM TO ASTM A307 OR AGL ABOVE GROUND LEVEL GA GAUGE PLYWD PLYWOOD SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS AND CERTIFICATES, ETC., REQUIRED BY AUTHORITY HAVING JURISDICTION SHALL BE PROCURED AND PAID FOR BY THE ASTM A36. ALL STRUCTURAL FASTENERS FOR STRUCTURAL STEEL FRAMING SHALL CONFORM TO ASTM A325. A/C AIR CONDITIONING GALV GALVANIZED PT PRESSURE TREATED SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON CONTRACTOR. FASTENERS SHALL BE 5/8" MIN. DIA. BEARING TYPE CONNECTIONS WITH THREADS EXCLUDED FROM THE PLANE. ALL APPROX APPROXIMATELY GC GENERAL CONTRACTOR PROJ PROJECT HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIELD EXPOSED FASTENERS, NUTS, AND WASHERS SHALL BE GALVANIZED OTHERWISE NOTED. CONCRETE EXPANSION AZ AZIMUTH GRND GROUND PROP PROPERTY RETHE ARCHITECT WILL BE PROVIDING CONSTRUCTION2. MORRISON HERSHFIELD CORPORATION HAS NOT CONDUCTED, NOR DOES IT INTEND TO CONDUCT ANY INVESTIGATION ANCHORS SHALL BE HILT! KWIK BOLTS UNLESS OTHERWISE NOTED. ALL ANCHORS INTO CONCRETE SHALL BE GYP BD GYPSUM WALL BOARD (P) PROPOSED REVIEW OF THIS PROJECT. AS TO THE PRESENCE OF HAZARDOUS MATERIAL, INCLUDING, BUT NOT LIMITED TO, ASBESTOS WITHIN THE CONFINES STAINLESS STEEL BLDG BUILDING V��D /1 ^� OF THIS PROJECT. MORRISON HERSHFIELD CORPORATION DOES NOT ACCEPT RESPONSIBILITY FOR THE BLK BLOCKING HT HEIGHT QTY QUANITY A/r INDEMNIFICATION, THE REMOVAL, OR ANY EFFECTS FROM THE PRESENCE OF THESE MATERIALS. IF EVIDENCE OF 2. NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL VERIFY MAGNETIC NORTH AND NOTIFY HVAC HEATING VENTILATION AIR HAZARDOUS MATERIALS IS FOUND, WORK IS TO BE SUSPENDED AND THE OWNER NOTIFIED. THE CONTRACTOR IS NOT CONSULTANT OF ANY DISCREPANCY BEFORE STARTING CONSTRUCTION. CLG CEILING CONDITIONING REQ REQUIRED y TO PROCEED WITH FURTHER WORK UNTIL INSTRUCTED BY THE OWNER IN WRITING. q CENTERLINE HORZ HORIZONTAL RM ROOM ROBERT J. �� 3. PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND CONDUCTORS. USE STAINLESS STEEL CLR CLEAR HR HOUR RO ROUGH OPENING V 3. ALL MATERIAL FURNISHED UNDER THIS CONTRACT SHALL BE NEW, UNLESS OTHERWISE NOTED. ALL WORK SHALL BE HARDWARE THROUGHOUT. CONC CONCRETE ROW RIGHT OF WAY V GUARANTEED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. THE CONTRACTOR SHALL REPAIR OR REPLACE AT CONST CONSTRUCTION N NCH ^ HIS EXPENSE ALL WORK THAT MAY DEVELOP DEFECTS IN MATERIALS OR WORKMANSHIP WITHIN SAID PERIOD OF TIME 4. THOROUGHLY REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES REQUIRING GROUND CONNECTIONS. CONT CONTINUOUS NFONN FOH DIAMETER SIM SIMILAR W L " A RA OR FOR ONE YEAR AFTER THE FINAL ACCEPTANCE OF THE ENTIRE PROJECT, WHICHEVER IS GREATER. 5. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. ALL BENDS TO BE A DET DETAIL NSUL NSULATION SPEC SPECIFICATION License#5897 -i i' 4. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING MIN. OF 8" RADIUS. DIA DIAMETER NT NTERIOR SF SQUARE FOOT CONDITIONS AND UTILITIES AT THE JOB SITE BEFORE WORK IS STARTED. NO CLAIMS FOR EXTRA COMPENSATION FOR DIAL DIAGONAL BC NTERNATIONAL BUILDING CODE SS STAINLESS STEEL 1 3 LA N T/,II O N r ^1 • WORK WHICH COULD HAVE BEEN FORESEEN BY AN INSPECTION, WHETHER SHOWN ON THE CONTRACT DOCUMENTS OR 6. FOR GROUNDING TO BUILDING FRAME AND HATCH PLATE GROUND BARS. USE A TWO-BOLT HOLE NEMA DRILLED DIM DIMENSION STL STEEL NOT, WILL BE ACCEPTED OR PAID. CONNECTOR SUCH AS T&B 32007 OR APPROVED EQUAL. DBL DOUBLE LBS POUNDS STRUCT STRUCTURAL ` r DN DOWN STD STUD �" 5. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING DIMENSIONS AND 7. FOR ALL EXTERNAL GROUND CONNECTIONS, CLAMPS AND CADWELDS, APPLY A LIBERAL PROTECTIVE COATING OR AN DWG DRAWING MGR MANAGER SUSP SUSPENDED �� CONDITIONS AT THE JOB SITE WHICH COULD AFFECT THE WORK UNDER THIS CONTRACT. ALL MANUFACTURERS ANTI-OXIDE COMPOUND SUCH AS "NO-OXIDE A" BY DEARBORN CHEMICAL COMPANY. MFR MANUFACTURER �` !'AJ RECOMMENDED SPECIFICATIONS, EXCEPT THOSE SPECIFICATIONS HEREIN, WHERE MOST STRINGENT SHALL BE COMPLIED EA EACH MAX MAXIMUM THRU THROUGH v 6. WITH.HECONTRACTOR SHALL VERIFY AND COORDINATE SIZE AND LOCATION OF ALL OPENINGS FOR STRUCTURAL, 8. REPAIRC ALL GALVANIZED IZING NFACES THAT HAVE BEEN DAMAGED BY THERMO-WELDING. USE ERICO T-319 GALVANIZING ELECLV ELECTRICQ EQUALATONL MECMIN H MINIMUM CAL TANG TINNED E BAR/COLD GALVANIZING PAINT. ELEV ELEVATION MTL METAL TYP TYPICAL Sep 16 20T6°F C�sran MECHANICAL, ELECTRICAL, PLUMBING, CIVIL, OR ARCHITECTURAL WORK. 9. SEAL ALL CONDUIT PENETRATIONS INTO MODULAR BUILDING WITH A SILICONE SEALANT AND ALL CONDUIT OPENINGS. EQUIP EQUIPMENT MISC MISCELLANEOUS UG UNDERGROUND ROBERT JERRY LARA (E) EXISTING UNO UNLESS NOTED OTHERWISE 7. THE CONTRACTOR SHALL VERIFY THAT NO CONFLICTS EXIST BETWEEN THE LOCATIONS OF ANY AND ALL MECHANICAL, 10. ANTENNAS AND COAX TO BE PROVIDED BY VERIZON WIRELESS, CONTRACTOR TO COORDINATE DELIVERY. EXT EXTERIOR REGISTERED ARCHITECT ELECTRICAL, PLUMBING, OR STRUCTURAL ELEMENTS, AND THAT ALL REQUIRED CLEARANCES FOR INSTALLATION AND N/A NOT APPLICABLE VIF VERIFY IN FIELD STATE OF OREGON MAINTENANCE ARE MET. NOTIFY THE CONSULTANT OF ANY CONFLICTS. THE CONSULTANT HAS THE RIGHT TO MAKE FIN FINISH NIC NOT IN CONTRACT VERT VERTICAL 5897 MINOR MODIFICATIONS IN THE DESIGN OF THE CONTRACT WITHOUT THE CONTRACTOR GETTING ADDITIONAL FLR FLOOR NTS NOT TO SCALE A COMPENSATION. FLUOR FLUORESCENT WP WATER PROOF CONSTRUCTION FT FOOT OC ON CENTER W/ WITH 1 8. DO NOT SCALE THE DRAWINGS. DIMENSIONS ARE EITHER TO THE FACE OF FINISHED ELEMENTS OR TO THE CENTER OD OUTSIDE DIAMETER W/O WITHOUT _ - _ LINE OF ELEMENTS, UNLESS NOTED OTHERWISE. CRITICAL DIMENSIONS SHALL BE VERIFIED AND NOTIFY THE CONSULTANT OF ANY DISCREPANCIES. - - - 1 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY CLEAN UP OF ALL TRADES AND REMOVE ALL DEBRIS FROM - THE CONSTRUCTION SITE. AT THE COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL THOROUGHLY CLEAN THE -- UGP- UG POWER CONDUIT - UGT- UG TELCO CONDUIT 0 09/19/16 ISSUED FOR CONSTRUCTION BUILDING, SITE, AND ANY OTHER SURROUNDING AREAS TO A BETTER THAN EXISTING CONDITION. PROJECT INFORMATION 10. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION C 09/08/16 ISSUED FOR REVIEW AGAINST DAMAGE, BREAKAGE, COLLAPSE, ETC. ACCORDING TO APPLICABLE CODES, STANDARDS, AND GOOD CONSTRUCTION PRACTICES. 1. THIS IS AN UNMANNED FACIUTY AND RESTRICTED ACCESS EQUIPMENT AND WILL BE USED FOR THE TRANSMISSION OF B 06/27/16 ISSUED FOR REVIEW RADIO SIGNALS FOR THE PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE. a 11. THE CONTRACTOR SHALL MEET ALL OSHA REQUIREMENTS FOR ALL INSTALLATIONS. A 05/16/16 ISSUED FOR REVIEW 2. VERIZON WIRELESS CERTIFIES THAT THIS TELEPHONE EQUIPMENT FACIUTY WILL BE SERVICED ONLY BY VERIZON 1 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES TO THE EXISTING CONSTRUCTION AND REPAIR ALL WIRELESS EMPLOYEE SERVICE PERSONNEL FOR REPAIR PURPOSES ONLY. THIS FACILITY IS UNOCCUPIED AND NOT : DAMAGES TO BETTER THAN NEW CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DAMAGE TO DESIGNED FOR HUMAN OCCUPANCY THUS IT IS NOT OPEN TO THE PUBLIC. No. Date Revision THE BUILDING SITE OR ANY ADJACENT STRUCTURES AROUND THE PROJECT. THE CONSULTANT SHALL BE SOLE AND FINAL JUDGE AS TO THE QUALITY OF THE REPAIRED CONSTRUCTION. ANY ADDITIONAL MODIFICATIONS WHICH MUST BE 3. THIS FACIUTY WILL CONSUME NO UNRECOVERABLE ENERGY. Client: MADE SHALL BE MADE AT THE CONTRACTOR'S EXPENSE. 4. NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION. 13. WHERE ONE DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS, EVEN THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS OR REFERRED TO IN THE SPECIFICATIONS, UNLESS NOTED 5. NO WASTE WATER WILL BE GENERATED AT THIS LOCATION. OTHERWISE. Verizon 6. NO SOLID WASTE WILL BE GENERATED AT THIS LOCATION. 14. WHERE NEW PAVING, CONCRETE SIDEWALKS OR PATHS MEET EXISTING CONSTRUCTION, THE CONTRACTOR SHALL MATCH THE EXISTING PITCH, GRADE, AND ELEVATION SO THE ENTIRE STRUCTURE SHALL HAVE A SMOOTH TRANSITION. 7. VERIZON WIRELESS MAINTENANCE CREW (TYPICALLY ONE PERSON) WILL MAKE AN AVERAGE OF ONE TRIP PER MONTH AT ONE HOUR PER VISIT. 15. THE CONTRACTOR SHALL MODIFY THE EXISTING FLOORS, WALL, CEILING, OR OTHER CONSTRUCTION AS REQUIRED TO GAIN ACCESS TO AREAS FOR ALL MECHANICAL, PLUMBING, ELECTRICAL, OR STRUCTURAL MODIFICATIONS. WHERE THE EXISTING CONSTRUCTION DOORS, PARTITIONS, CEILING, ETC., ARE TO BE REMOVED, MODIFIED, OR REARRANGED OR Implementation Team: WHERE THE EXPOSED OR HIDDEN MECHANICAL, ELECTRICAL SYSTEMS ARE ADDED OR MODIFIED, THE GENERAL _ CONTRACTOR SHALL REPAIR, PATCH AND MATCH ALL EXISTING CONSTRUCTION AND FINISHES OF ALL FLOORS WALLS AND CEILINGS. WHERE CONCRETE MASONRY CONSTRUCTION IS MODIFIED,THE CONTRACTOR SHALL TOOTH IN ALL NEW • CONSTRUCTION TO MATCH THE EXISTING BOND. WHERE CONCRETE CONSTRUCTION IS MODIFIED, THE CONTRACTOR , SHALL VERIFY THE EXACT DETAILS TO BE USED FOR CONSTRUCTION. ALL WORK SHALL BE COVERED UNDER THE GENERAL CONTRACT. /076 \ 16. VERIFY ALL EXISTING DIMENSIONS PRIOR TO PERFORMING WORK. 17. VERIFY LOCATION OF ALL BURIED UTILITIES PRIOR TO ANY EXCAVATION. BLACK ROCK 18. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR APPLYING FOR COMMERCIAL POWER IMMEDIATELY UPON AWARD OF CONTRACT. THE GENERAL CONTRACTOR IS REQUIRED TO KEEP ALL DOCUMENTATION RECEIVED FROM THE A&E Team: 1 POWER COMPANY, ACKNOWLEDGING APPLICATION FOR POWER, WRITTEN AND VERBAL DISCUSSIONS WITH THE POWERIll COMPANY, ETC. Mr's 19. THE GENERAL CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION OF THE EXPECTED DATE OF COMPLETION OF THE POWER CONNECTION FROM THE POWER COMPANY. MORRISON HERSHFIELD 20. IF THE POWER COMPANY IS UNABLE TO PROVIDE THE POWER CONNECTION BY OWNER'S REQUIRED DATE, THE 600 STEWART ST,SUITE 200 GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN A TEMPORARY GENERATOR UNTIL THE POWER COMPANY SEATTLE,WA 98101 CONNECTION IS COMPLETED. COSTS ASSOCIATED WITH THE TEMPORARY GENERATOR TO BE APPROVED BY THE OWNER. IMPORTANT NOTICE Tel:206.268.7370 • www.monisonhershfield.com 21. IF THE GENERAL CONTRACTOR FAILS TO TAKE NECESSARY MEASURES AS DESCRIBED IN NOTES 19, 20 AND 21 ABOVE, THE GENERAL CONTRACTOR SHALL PROVIDE A TEMPORARY GENERATOR AT NO COST TO THE OWNER. THE EXISTING CONDITIONS REPRESENTED HEREIN ARE BASED ON VISUAL OBSERVATIONS AND INFORMATION PROVIDED BY OTHERS. MORRISON HERSHFIELD CORPORATION CANNOT GUARANTEE THE CORRECTNESS NOR COMPLETENESS OF THE Project Info: 22. PLANS PART OF THIS SET ARE COMPLEMENTARY. INFORMATION IS NOT LIMITED TO ONE PLAN. DRAWINGS AND EXISTING CONDITIONS SHOWN AND ASSUMES NO RESPONSIBILITY THEREOF. CONTRACTOR AND HIS SUB-CONTRACTORS SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT, WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. THEY ARE NOT TO BE USED BY THE OWNER ON OTHER SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS AS REQUIRED FOR PROPER EXECUTION OF PROJECT. REPORT POR ANY CONFLICTS OR DISCREPANCIES TO THE CONSULTANT PRIOR TO CONSTRUCTION. TUALATIN I�� • PROJECTS OR EXTENSION TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE I COMPENSATION TO THE ARCHITECT. THESE PLANS WERE PREPARED TO BE SUBMITTED TO GOVERNMENTAL BUILDING AUTHORITIES FOR REVIEW FOR COMPLIANCE WITH APPLICABLE CODES AND IT IS THE SOLE RESPONSIBILITY OF THE 6975 SW SANDBURG STREET OWNER AND/OR CONTRACTOR TO BUILD ACCORDING TO APPLICABLE BUILDING CODES. TIGARD, OR 97223 23. IF CONTRACTOR OR SUB-CONTRACTOR FIND IT NECESSARY TO DEVIATE FROM ORIGINAL APPROVED PLANS, THEN IT IS Drawing Title: THE CONTRACTOR'S AND THE SUB-CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE ARCHITECT WITH 4 COPIES OF THE PROPOSED CHANGES FOR HIS APPROVAL BEFORE PROCEEDING WITH THE WORK. IN ADDITION THE CONTRACTOR AND SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY APPROVALS FROM THE BUILDING AUTHORITIES FOR THE PROPOSED CHANGES BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR AND SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FROM LEGEND BUILDING AUTHORITIES DURING THE EXECUTION OF THE WORK. GENERAL NOTES 24. IN EVERY EVENT, THESE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS SHALL BE INTERPRETED TO BE A MINIMUM BUILDING/WALL/DETAIL SECTION LARGE SCALE DETAIL AND SYMBOLS ACCEPTABLE MEANS OF CONSTRUCTION BUT THIS SHALL NOT RELIEVE THE CONTRACTOR, SUB-CONTRACTOR, AND/OR SUPPLIER/MANUFACTURER FROM PROVIDING A COMPLETE AND CORRECT JOB WHEN ADDITIONAL ITEMS ARE REQUIRED :. TO THE MINIMUM SPECIFICATION. IF ANY ITEMS NEED TO EXCEED THESE MINIMUM SPECIFICATIONS TO PROVIDE A DETAIL NUMBER 9 DETAIL NUMBER A COMPLETE, ADEQUATE AND SAFE WORKING CONDITION, THEN IT SHALL BE THE DEEMED AND UNDERSTOOD TO BE a INCLUDED IN THE DRAWINGS. FOR EXAMPLE, IF AN ITEM AND/OR PIECE OF EQUIPMENT REQUIRES A LARGER WIRE IN__O Project Number: Start Date: SIZE (I.E. ELECTRICAL WIRE), STRONGER OR LARGER PIPING, INCREASED QUANTITY (I.E. STRUCTURAL ELEMENTS), ® MIR7160045 05/03/16 REDUCED SPACING, AND/OR INCREASED LENGTH (I.E. BOLT LENGTHS, BAR LENGTHS) THEN IT SHALL BE DEEMED AND SHEET NUMBER UNDERSTOOD TO BE INCLUDED IN THE BID/PROPOSAL. THESE DOCUMENTS ARE MEANT AS A GUIDE AND ALL ITEMS SHEET NUMBER Drafter. Designer: REASONABLY INFERRED SHALL BE DEEMED TO BE INCLUDED. WHERE DETAILED WHERE DETAILED LW SV 25. THESE CONTRACT DOCUMENTS AND SPECIFICATIONS SHALL NOT BE CONSTRUED TO CREATE A CONTRACTUAL Project Manager. Professional of Record: RELATIONSHIP OF ANY KIND BETWEEN THE ARCHITECT AND THE CONTRACTOR. REFERENCE ELEVATION DETAIL BUG RKL RL 26. IN RAWLAND CONDITIONS, TOWER FOUNDATION STRUCTURAL STEEL TO BE GROUNDED PRIOR TO CONCRETE POUR. DETAIL NUMBER TOWER FOUNDATION STRUCTURAL STEEL TO BE CONNECTED TO PERMANENT GROUND ROD PRIOR TO TOWER ERECTION. Revision No: Sheet No: TOWER GROUND MUST BE MAINTAINED AT ALL TIMES. ® ® 0 REFERENCED SHEET NUMBER T-2 DRAWING WHERE DETAILED . .,.w.., DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADWSE CONSULTANTS OF ANY ERRORS OR NOTE: THIS IS NOT A SURVEY. ALL INFORMATION AND SHIS N SHALL E IMPLEMENTEDPE M TIONS TO WORK SHOWN BE WITHOUT PRIOR WRITTEN TRUE NORTH HAVE BEEN OBTAINED FROM EXISTING APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS AND DRAWINGS AND JURISDICTIONAL GIS INFORMATION SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON AND ARE APPROXIMATE. HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIELD NOR THE ARCHITECT WILL BE PROVIDING CONSTRUCTION NREVIEW OF THIS PROJECT. ► � �RED ARc ti I ROB ERT J. 2, W LARA a ® GY License#5897 (\PLANTA PION, =1 • I \ ti � , R�� F� I \ �� Sep 16 20T60 F ?Sr is I \\ �� REGISTEREDRRY LARA ROBERT E ARCHITECT STATE OF OREGON 5897 11'Z'' 'C'D j" CONSTRUCTION EXISTING ADJACENT It- — — — �PROPERTY LINE (TYP) , 0 o_ 0 09/19/16 ISSUED FOR CONSTRUCTION I C 09/08/16 ISSUED FOR REVIEW I B 06/27/16 ISSUED FOR REVIEW A 05/18/16 ISSUED FOR REVIEW No. Date Revision w z Client: I� P� � i ci verizon PARCEL NUMBER: 2( F /`27—2"f W262492 4)- . 9Y r en•®Ii ; M M®-a® ra CA cc r S `.r/� Implementation Team: w Q R A a a w \ 1 _ Ill e BLACK ROCK ,L ❑ ®®®® \ o EXISTING PARKING a ®®®® ,\ X\ A&E Team: pro iii<EGRESS l �y}C0 ❑❑❑ ®®®® �� �� INGRESS ❑ ❑ ❑ \ �� MORRISON HERSHFIELD __ ❑ 600 STEWART ST,SUITE 200 PROPERTY LINE —— —— / \44\4\ -��` �j \ SEATTLE,WA 98101 -d\tel %J°iPb- \ 0 Tel:206.268.7370 if \ / www.monisonhershfeld.mm __ �mice!®i.�tam®! — \.q __ __ _ __ _41111h,_ PROPERTY LINE _ Project Info: 21'-9"± POR u) TUALATIN 6975SW RG STREET TIGARD OR 09 223 D Drawing Title: CO a Z I N SITE PLAN 0 _ 1Project Number: Start Date: ® 7160045 05/03/16 -- a Drafter: Designer: 1 LW SV Project Manager: Professional of Record: - RKL RL Know what's below. Revision No: Sheet No: Call before you dig. O A— 1 11x17" SCALE 1" = 60'-o' 30' 1PM"b. SO' SITE PLAN 1 _ ..,. .„ .• . DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS C OMISSIONS.NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHO,TO T PRIOR WRITTEN EXISTING PANEL ANTENNAS, OF OTHERS, TYP APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS AN SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON N HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIEI NOR THE ARCHITECT WILL BE PROVIDING CONSTRUCTION REVIEW OF THIS PROJECT. iii /111 BRED A Rc Ai • h ROB ERT J. 2 �/ \ r LARA : i 4/7/4" � ' 1 SECTOR 3 `\: EXISTING PANEL ANTENNAS, OF OTHERS, TYP License#5897 —' loories\ / DLANTfd1lON, '. • / C k \N\-, i • 176" 0' Sep 16 20 T6 _ ROBERT JERRY LARA �' REGISTERED ARCHITECT STATE OF OREGON EXISTING OVP TO REMAIN 5897 EXISTING DOGHOUSE W/ (1) EXISTING VERIZON WIRELESS I VACANT PORT & GROUND CABLE CONSTRUCTION ROOFTOP MOUNT, TO BE IEXISTING VERIZON WIRELESS - - - UPGRADED I EQUIPMENT ROOM (#360), BELOW EXISTING HYBRID CABLE FROM I L„....----- '"' \ - - - EQUIPMENT ROOM BELOW TO REMAIN L — \ EXISTING CABLE TRAY W/ (8) 1-7/8" COAX I \----) TO REMAIN & (2) HYBRID CABLES FROM - 0 09/19/16 ISSUED FOR CONSTRUCTIC SECTOR 3'S OVP TO BE REMOVED EXISTING HVAC EQUIPMENT, TYP PROPOSED VERIZON WIRELESS TO ADD (1) _ J C 09/08/16 ISSUED FOR REVIEW PROPOSED HYBRID/ CABLE PORT AT EXISTING DOGHOUSE PROPOSED VERIZON WIRELESS FIBERWCABL/ E -" BELOW TO SECTORS 1 d�c 2 (TYP OFFROM U M1 PER T SECTOR) EXISTING ROOFTOP SKYLIGHTS, NP 8 06/27/16 ISSUED FOR REVIEW _ A 05/18/16 ISSUED FOR REVIEW I No. Date Revision Client: Mal _ REFER TO SHEET RF-1 FOR A DETAILED ' ANTENNA CONFIGURATION PLAN r..----r.,...- verizon ., • \ " EXISTING PANEL ANTENNAS, OF OTHERS, TYP \ // Implementation Team: V', f \O BLACK ROCK I- .... --,1 y A&E Team: EXISTING VERIZON WIRELESS \ ® ROOFTOP MOUNT, TO BE III 1 UPGRADED I \ EXISTING VERIZON WIRELESS PANEL r ANTENNA (TYP OF 3, 1 PER SECTOR) MORRISON HERSHFIELC 600 STEWART ST,SUITE 200 —� Wig, SECTOR 1 SEATTLE,WA 98101 ��L ' Tel:206. 0 www.morrisonhershfield.com Project Info: 11 PROPOSED VERIZON WIRF1 FSS PANEL POR �„ ANTENNA(TYP OF 6, 2 PER SECTOR) TUALATIN 6975 SW SANDBURG STREET PROPOSED VERIZON WIRELESS TIGARD, OR 97223 RRU-A2 MOUNTED BEHIND ANTENNA \ (TYP OF 9, 3 PER SECTOR) Drawing Title: Il \� /� 'j PROPOSED i• ROOF PLAN `�- _ - III EXISTING ROOFTOP HATCH \ :�, %�r' EXISTING ROOFTOP MOUNTS, OF OTHERS, TYP r' Project Number: Start Date: EXISTING PANEL ANTENNAS, OF OTHERS, TYP `S - EXISTING PANEL ANTENNAS, OF OTHERS, TYP 7160045 05/03/16 Drafter: Designer: LW SV EXISTING VERIZON WIRELESS Project Manager: Professional of Recor is } ROOFTOP MOUNT, TO BE - UPGRADED RKL RL Revision No: Sheet No: SECTOR 2 ONLYNLYVERIZON WIRELESS ANTENNAS AT 39'-0" TIP HEIGHT SHOWN FOR CLARITY. SEE ELEVATIONS. _ 0 A- 1 . 1 22"x34" SCALE: 3/16" = 1'-0" ROOF PLAN 1 `' 11"x17" SCALE: 3/32" = 1'-0" 4' 2 0 4' PROPOSED VERIZON WIRELESS PANEL DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR ANTENNA MOUNTED ON IXISTING ANTENNA OMISSIONS.NO VARIATIONS OR MODIFICATIONS TO WORK MOUNT OW OF 6, 2 PER SECTOR) SHOWN SHALL RE IMPLEMENTED WITHOUT PRIOR WRITTEN kiTOP OF EXISTING PANEL ANTENNAS - APPROVAL.ALL PREVIOUS ISSUES OF THIS DRAWING ARE Y SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS AND 47'-O" AGL SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON WRIT. XISTING VERIZON WIRELESS RAYCAP HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIELD SPLIITER/SURGE SUPPRESSOR (OW) (TYP OF 2) NOR THE ARCHITECT WILL BE PROVIDING HUCSON ab OOFPROPOSED PANEL ANTENNAS — _ I - REVIEW OF THIS PROJECT. „di 0OF" AGLSTING PANEL ANTENNAS / EXISTINGANTENNARIMOUNT,ZON TO BE _ PROPOSED'VERIZON WIRELESS RRU—A2 I�ED ,Q Q�� UPGRADED MOUNTED ON DUSTING ANTENNA MOUNT GV 1 i�" (TYP OF 9, 3 PER SECTOR) •TOP OF EXISTING PANEL ANTENNAS EXISTING HVAC EQUIPMENT _ 37'-O" AGL �� ROBERT J. /A` `/... " Ji TOP OF EXISTING PARAPET \ ri , I �� �• 3T-0" AGL W LARA n hBOTTOM OF EXISTING PARAPET _-� - [Y �- Y35'-0" AGL / License#5897 EXISTING PANEL ANTENNAS, OF OTHERS J EXISTING PANEL ANTENNAS, OF OTHERS LA N T/,I l O N L 'I • I, ...- C.C. fli• � RAJ NOTE: 16 G ` (� NO WORK TOWER/ANTENNA LMOUNT STRUCTURAL ANALYSISTHOUT THE REPORTOVEDSep 20160 F O �.'-'7�ion (SIGNED AND SEALED) PROVIDED BY OTHERS UNDER SEPARATE COVER. CONTRACTOR PRIOR TO INSTALLATIONROB ERT JERRY LARA OF ANTENNAS, EQUIPMENT AND COAX CABLES SHALL REGISTERED ARCHITECT REVIEW THE APPROVED TOWER STRUCTURAL ANALYSIS STATE OF OREGON PROVIDED BY VERIZON WIRELESS AND MODIFY, IF 5897 '. REQUIRED, ALL APPLICABLE MEMBERS AS INDICATED IN CONSTRUCTION THE CERTIFIED STRUCTURAL. PAINT NOTE PROPOSED ANTENNAS, HARDWARE & COAX TO - - - BE PAINTED TO MATCH EXISTING ANTENNAS. 0 09/19/16 ISSUED FOR CONSTRUCTION EXISTING BUILDING C 09/08/16 ISSUED FOR REVIEW B 06/27/16 ISSUED FOR REVIEW A 05/18/16 ISSUED FOR REVIEW No. Date Revision Client: gip EXISTING Y ASSUMED 0'A OE AGL verizonv , 22"x34" SCALE: 3/16" = 1'-0" —� PROPOSED BUILDING PROFILE 2 • 11"x17" SCALE: 3/32" = 1'-0" 4' 2 0 4' EXISTING VERIZON WIRELESS PANEL ANTENNA TO REMAIN (TYP OF 3, 1 PER SECTOR) Implementation Team: EXISTING VERIZON WIRELESS DIPLEXER TO BE REMOVED, (TYP OF 6, 2 PER SECTOR), BEHIND h TOP OF EXISTING PANEL ANTENNAS / - - Y47'-0" AGL EXISTING VERIZON WIRELESS PANEL ANTENNA ,� TOP OF EXISTING PANEL ANTENNAS TO BE REPLACED (TYP OF 6, 2 PER SECTOR) (\( (1 /o(0 �43'-0" AGL I1 n EXISTING VERIZON WIRELESS ANTENNA MOUNT II I \\\\\w\ II I EXISTING VERIZON WIRELESS RRU NP _ EXISTING VERIZON WIRELESS RAYCAP / \i EXISTING HVAC EQUIPMENT II I ( I I SPLITTER/SURGE SUPPRESSOR (OVP) TOP OF EXISTING PANEL ANTENNAS I I — I OF 3, 1 PER SECTOR), TO BE REPLACED I I (TYP OF 2), T'0 BE REPLACED, BEHIND BLACK ROCK "r 37-0" AGL ____ I A&E Team: TOP OF EXISTING PARAPET \ J a 1 L)� �� ' �� 37'-0" AGL �BOTTOM OF EXISTING PARAPET _ _, — — — — 35'-O" AGL MORRISON HERSHFIELD \ EXISTING PANEL ANTENNAS, OF OTHERS 600 STEWART ST,SUITE 200 EXISTING PANEL ANTENNAS, OF OTHERS SEATTLE,WA 98101 Tel:206.268.7370 www.monisonhershfield.com Project Info: POR 1 TUALATIN 6975 SW SANDBURG STREET TIGARD, OR 97223 Drawing Title: EXISTING AND NBUILDIOGP POROFILES EXISTING BUILDING Project Number: Start Dote: 7160045 05/03/16 • 1 Drafter. Designer. LW SV Project Manager: Professional of Record: RKL RL Revision No: Sheet No: - } EXISTING GRADE I ASSUMED 0-O" AGL - B 0 A-2 1 22".34"SCALE: 3/16" = 1'-0" - - EXISTING BUILDING PROFILE 1 11"K17"SCALE 3/32" = 1'-0" 4 2 0 4' DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL NOTES: DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS C 1. INSTALL ANTENNAS PER MANUFACTURER SPECIFICATIONS OMISSIONS.NO VARIATIONS OR MODIFICATIONS TO WORKSHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN 2. CONTRACTOR TO TORQUE ALL MOUNTING HARDWARE APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE PER MANUFACTURER SPECIFICATIONS SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS ANT SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIELL NOR THE ARCHITECT WILL BE PROVIDING CONSTRUCTION REVIEW OF THIS PROJECT. ,-,...'S, ,....x,ARC ti ,Iy DIM 2 DIM 2 DIM 3 ROB ERT J. W LARA QTY DIM 1 DIM 2 DIM 3 WEIGHT rr License#5897 —i SECTOR ALPHA SBNHH-1 D45C 2 95.9" 18.0" 7.0" 79.6 LBS ' .D LA N TE,I I O N, FI • X7CAP-480 1 50.5" 14.6" 7.8" 30.0 LBS c 111 P.1. �� SECTOR BETA F 0 o SBNHH-1D45C 2 95.9" 18.0" 7.0" 79.6 LBS Sep 1 6V 20160 F O C� X7CAP-480 1 50.5" 14.6" 7.8" 30.0 LBS Sep G ROBERT JERRY LARA REGISTERED ARCHITECT SECTOR GAMMA STATE OF OREGON 5897 SBNHH-1D450 2 95.9" 18.0" 7.0" 79.6 LBS CONSTRUCTION X7CAP-480 1 50.5" 14.6" 7.8" 30.0 LBS 1=x s., I \ _ _ _ FRONT BACK SIDE — — — •y�, 4,DIM 2 4, 0 09/19/16 ISSUED FOR CONSTRUCTION ro 0 1� 1:1—D1 C 09/08/16 ISSUED FOR REVIEW TOP B 06/27/16 ISSUED FOR REVIEW A 05/18/16 ISSUED FOR REVIEW No. Date Revision Client: verizon 22"x34" SCALE: NOT TO SCALE PROPOSED ANTENNA DIMENSIONS 3 • 11"x17" SCALE: NOT TO SCALE Implementation Team: , /0‘0 A,\\ BLACK ROCK A&E Team: MORRISON HERSHFIELD GALV SCH 40 PIPE MOUNT , GALV SCH 40 PIPE MOUNT 600 STEWART ST,SUITE 200 SEATTLE,WA 98101 Tel:206.268.7370 MECHANICAL DOWN TILT KIT (AS REQ'D) BY % I MECHANICAL DOWN TILT www.morrisonhershfield.com ANTENNA MANUFACTURER KIT (AS REQ'D) BY GALV SCH 40 I - 6975 ANTENNA MANUFACTURER Project Info: Tell PIPE MOUNTANTENNA MOUNT BRACKETSPOR BY ANTENNA MANUFACTURERPANEL ANTENNA TUALATIN SW SANDBURG STREET PANEL ANTENNA PANEL ANTENNA TIGARD, OR 97223 I ANTENNA MOUNT BRACKETS Drawing Title: ANTENNA MOUNT 1 BY ANTENNA MANUFACTURER 2 TOP VIEW BRACKETS TENNA MANUFAY NTURER iiar. ssl: t. CONSTRUCTION RRU—A2 DETAILS -, I I /-RRU—A2 Project Number: Start Date: a 7160045 05/03/16 Drafter: Designer: J LW SV Project Manager: Professional of Record: RKL RL Revision No: Sheet No: 0 A-3 22"x34" SCALE: NOT TO SCALE NOT USED 2 22"x34" SCALE: NOT TO SCALE TYPICAL ANTENNA ATTACHMENT 1 11"x17" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS.NO VARIATIONS OR MODIFICATIONS TO WORK MANUFACTURER: ERICSSON SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN MODEL:HTRRUS 12 APPROVAL.D ALL PTHEI ISSUES OF THIS DRAWING SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS AND HEIGHT: 28.5" SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON WIDTH: 18.5" HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIELD DEPTH: 7.36" MANUFACTURER: ERICSSON NOR THE ARCHITECT WILL BE PROVIDING CONSTRUCTION WEIGHT: 57.96 LBS MODEL: RRUS A2 REVIEW OF THIS PROJECT. HEIGHT: 16.4" (7.....'S ,�C D A�C x,36 WIDTH: 15.1" G ��� WALL DEPTH: 3.4" PIPE / WALL-MOUNT BRACKET DED BY WEIGHT: 22 LBS PROV r,, /v MANUFACTURER ACTU ER (TYP.) NOTE; fA ROBERT J. '� • PROVIDEDPIPE-MO BRACKET I' R MOUNTING ATTACH (PIPE AP RED" RRUs MANUFACTUURER W LARA n MANUFACTURER (iYP.) RRUS 12 SPECIFICATIONS ....--N _ � License#5897 --� .... 7 ATTACH RRUS A2 TO RRUS 12 PER I ` r •i'i444rirrrr+ MANUFACTURER SPECIFICATIONS IC LA N Tf, I O N I S"^ 10 rr*r.irir:r.rrrrrrrrrrr.rrrr \� Tail' rr:r1: C ir�rjr iiriirrr. •• RRUS A2 ! C" SINGLE RRU MOUNT WALL r `' WALL-MOUNT BRACKET r' Sep 16 20c6- F O C..2 Slafl PIPE / PROVIDED BY PIPE ROBERT JERRY LARA MANUFACTURER (GYP.) C, MOUNT PIPE-MOUNT BRACKET 4 ' i; PROVIDED BY jr • A„ r, REGISTERED ARCHITECT MANUFACTURER (GYP.) 11��� �� ±; STATE OF OREGON e16-01�'• •• r 5897 CONSTRUCTION I ii llII- „,,-., " r. T ' 0 09/19/16 ISSUED FOR CONSTRUCTION 1. . n DOUBLE RRU MOUNT r, C 09/08/16 ISSUED FOR REVIEW PIPE V ti >, B 06/27/16 ISSUED FOR REVIEW _ __. A 05/18/16 ISSUED FOR REVIEW �"'�� No. Date Revision PIPE-MOUNT BRACKET PROVIDED BY 1 Client: MANUFACTURER (TYP.) {�� , rill verizon TRIPLE RRU MOUNT �+ Implementation Team: " SCALE: NOT TO SCALE • 22"x34" SCALE: NOT TO SCALE RRU 12 DETAIL 6 13^x37^ SCALE: NOT TO SCALE RRU A2 DETAIL 5 11 o17” SCALE: NOT TO SCALE NOT USED 4 11"x17" SCALE: NOT TO SCALE 0°.0 1 MANUFACTURER: RAYCAP \ MODEL: RCMDC-3315-PF-48 HEIGHT: 19.18^ 5 BLACK ROCK TH:DEPTH: 110.20.25" WEIGHT: 26.9 LBS (WITH MOUNT) A&E Team: 15.73" . NOTE: CONTRACTOR TO PROVIDE Irn : U-BOLT FOR PIPE MOUNTING MORRISON HERSHFIELD 600 STEWART ST,SUITE 200 SEATTLE,WA 98101 LARGE RRU LARGE SQUARE ' Tel:206.268.7370 PIPE MOUNT RRU MOUNT LARGE ANGLE „Ts.,,, ' m www. ornsonhershfield.com I iiiiiiiii RRU MOUNT w- � 4 MN Project Info: a •' �. • � PLAN VIEW POR 0 �. O , 0 ", I •� ` TUALATIN I/ l'iOr 0 �II '' 6975 SW SANDBURG STREET �"y�� • :��� " �I TIGARD. OR 97223 e LO _, `�� @ 0 \` I! 4 - _ 1 Drawing Title: MOUNT PROVIDED BY MANUFACTURER (GYP.) SQUARE RRU SMALL ANGLE - CONSTRUCTION SMALL RRU MOUNT RRU MOUNT PIPE MOUNT m m m DETAILS �.•� m r 7" RAYCAP _ m � � x 411 ! I ' - 0 v v, �•. 4 a —I- Project Number Start Date: , '1111 411��41 0�' I —� _ 7160045 05/03/16 • o tr `0 �� I 'mg Drafter: Designer: )' - LW SV 10.25 Project Manager: Professional of Record: g• - RKL RL Revision No: Sheet No: MOUNTING BRACKET INCLUDED FRONT VIEW SIDE VIEW 0 A-4 • 22"x34" SCALE: NOT TO SCALE NOT USED 3 22";34"" SCALE: NOT TO SCALE SCALE: NOT TO SCALE RRU MOUNTING DETAIL 2 22"x34" SCALE: NOT TO SCALE RAYCAP SPLITTER/SURGE SUPPRESSOR DETAIL 1 11"x17" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE 1 • DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL I Y ERRORS OR AS FS SSSINSS MID ADVISE SOORUMTANOF EXISTING ANTENNA AND COAX SCHEDULE PROPOSED ANTENNA AND COAX SCHEDULE ODIMIMENSION.NO VARIATIONS OR MODIFICATIONSANOF ANY TO WORK NUMBER NUMBER OF ELEC MECH NUMBER OF FEEDER FEEDER ADDRIONAL SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN ELEC MECH NUMBER FEEDER FEEDER ADORIONAL SECTOR i AZIMUTH RAD CENTER VENDOR MODEL APPROVAL.ALL PREVIOUS ISSUES OF THIS DRAWING ARE SECTOR 1 AZIMUTH RAD CENTER ANTENNAS VENDOR MODEL TILT DOWNIILT FEEDERS TYPE LENGTH EQUIPMENT ANTENNAS TILT DOWNTILT FEEDERS TYPE LENGTH EQUIPMENT SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS AND SPECIFICATONS REMAIN THE PROPERTY OF MORRISON AWS 60' 39'-0" 1 CSS AXP15-60 0' 0' (2) DIPLEXER 700/AWS 30' 39'-0" 1 COMMSCOPE SBNHH-1D45C 4'/2* 0' HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIELD (3) RRU—A2 NOR THE ARCHITECT WILL BE PROVIDING CONSTRUCTION 850 60' 39'-0" 1 CSS X7CAP-480 O' r — — 150'-0"} (1) RRU 850 60' 3V-0" 1 CSS X7CAP-480 0' r 1 HYBRID 150'-0"} (1) U— REVIEW OF THIS PROJECT. Ow 700 30' 3V-0" 1 COMMSCOPE LNX-6512DS—VTM 0' 2' (1) OVP 700/PCS 30' 39'-0" 1 COMMSCOPE SBNHH-1D45C 4'/7 0' �FEEDER ADDMONAL oRc D q RC� SECTOR 2 AZIMUTH RAD CENTER NANTENNAS VENDOR MODEL TTILT DOWNTILT C MECH QUFEEDERS FEEDERMBER OF TYPE LEHNGTH EQUIPMENTSECTOR 2 AZIMUTH RAD CENTER ANTADDITIONAL ENNAS R VENDOR MODEL TIELLT DOWNTILT C MECH NU FEEDERS FEEDERMBER OF LENGTH EQUIPMENT G AWS 180' 39'-0" 1 CSS AXP15-60 0' 0' (2) DIPLEXER 700/AWS 180' 39'-0" 1 COMMSCOPE SBNHH-1D45C 4'/2' 0' 850 180' 39'-0" 1 CSS X7CAP-480 0' 2' — — 110'-0"± (1) RRU 850 180' 39'-0" 1 CSS X7CAP-480 0' 2' 1 HYBRID 110'-0"} (3) RRU—A2 C,. R 0 B E R T J. �� • (1) OVP (1) OVP 1t 700 180' 39'-0" 1 COMMSCOPE LNX-6512DS—VTM 0' 2'• 700/PCS 180' 3V-0" 1 COMMSCOPE SBNHH-1D45C 47r 0' Cv LARA `n. FEEDER OF ELEC UMBER DMONAL EY t SECTOR 3 AZIMUTH RAD CENTER NUMBER VENDOR MODEL ELEC DOWNTILT NUMBERERSOF FEEDER TYPE LENGTH EQUAD IDMS SECTOR 3 AZIMUTH RAD CENTER NUMBERANTEVENDOR MODEL ALT NFEEDERSF FUER LENGTH EQUIPMENTEQLicense#5897 --1 AWS 300' 39'-0" 1 CSS AXP15-60 0' 0' (2) DIPLEXER 700/AWS 300' 39'-0" 1 COMMSCOPE SBNHH-1D45C 4'/7 0' " 850 300' 39'-0" 1 CSS X7CAP-480 0• r - - so'-o"} (1) RRU (3) RRU—A2P LANT�,I IO\iyN L (1) ORP 850 300' 39'-0" 1 CSS X7CAP-480 0' 2' 1 HYBRID 50'—X"} (1) OVP ` 700 300' 39'-0" 1 COMMSCOPE LNX-6512DS—VTM 0' 2' 700/PCS 300' 39'-0" 1 COMMSCOPE SBNHH-1D45C 477 0" c NOTE: NO WORK SHALL COMMENCE WITHOUT THE APPROVED F 0 ` v TOWER/ANTENNA MOUNT STRUCTURAL ANALYSIS REPORT Sep 16 20 6 ���$� (SIGNED AND SEALED) PROVIDED BY OTHERS UNDER SEPARATE COVER. CONTRACTOR PRIOR TO INSTALLATION ROBERT JERRY LARA OF ANTENNAS, EQUIPMENT AND COAX CABLES SHALL REGISTERED ARCHITECT I REVIEW THE APPROVED TOWER STRUCTURAL ANALYSIS STATE OF OREGON PROVIDED BY VERIZON WIRELESS AND MODIFY, IF 5897 REQUIRED, ALL APPLICABLE MEMBERS AS INDICATED IN ' THE CERTIFIED STRUCTURAL. CONSTRUCTION 1 1111 114 _ _ _ 1 — — — i 0 09/19/16 ISSUED FOR CONSTRUCTION N C 09/08/16 ISSUED FOR REVIEW PROPOSED VfE IZON WIRELESS EXISTING VERIZON WIRELESS PANEL PANEL ANTENNA L7QQ/AWS] /I1 B 06/27/16 ISSUED FOR REVIEW ANTENNA [700]TO BE REMOVED EXISTING VERIZON WIRELESS ROOFTOP A 05/18/16 ISSUED FOR REVIEW EXISTING VERIZON WIRELESS /,: STR U CTU RAL N OT ES DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS.NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN 1. DESIGN DATA: APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS AND SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON 2014 OREGON STRUCTURAL SPECIALTY CODE HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIEID BASIC WIND SPEED 120 MPH (ASCE 7-10, NOR THE ARCHITECT WILL BE PROVIDING CONSTRUCTION ULTIMATE 3s GUST) REVIEW OF THIS PROJECT. RISKXPUREGORY il C � .REp Alk., EXPOSURE C 2. MATER ALS STRUCTURAL WF STEEL ONLY A992 (50 KSI) C;� R 0 B ERT J. /2` STRUCTURAL STEEL A572 (50 KSI) X—BRACING ANGLES A36 VII ' ANGLES & PLATES A36 W LARA SITEPRO SCX2 CROSSOVER PLATE OR HSS STRUCTURAL TUBING A500 GRADE B (46KSI) ' ry- APPROVED EQUAL STEEL PIPE A501 OR A53 GRADE B License#5897 NEW 2 1/2 STD PIPE HIGH STRENGTH BOLTS A325 N OR SC CLASS A IrLA N Tia I 0N, F. X 10'-6' LONG WELDING ELECTRODES E70XX (2) 1/2' U—BOLT (2) 1/2' U—BOLT 3. DESIGN, FABRICATION AND ERECTION SHALL BE IN r ACCORDANCE WITH THE FOLLOWING CODES: AISC 360 C SPECIFICATION FOR STRUCTURAL STEEL BUILDING AISC CODE It'F OF STANDARD PRACTICE. !�J',. 2 1/2'STD PIPE11111r 4. ALL BOLTED CONNECTIONS SHALL BE BEARING TYPE v r �. CONNECTIONS CONFORMING TO "RCSC SPECIFICATIONS FOR Sep 16 20c60 F ORC�-;Sian ` aiSTRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. 5. ALL STEEL BE HOT DIP GALVANIZED TO MEET THE ROBERT JERRY LARA REQUIREMENTS OF ASTM STANDARD SPECIFICATION A123 WITH REGISTERED ARCHITECT FIELD TOUCH DIP WITH ZINC RICH PAINT AFTER CONSTRUCTION. STATE OF OREGON 5897 6. FIELD VERIFY ALL DIMENSIONS PRIOR TO STEEL FABRICATION. J Imo■ A 7. ALL WELDING CONNECTIONS SHALL CONFIRM TO THE CONSTRUCTION REQUIREMENTS OF ANSI/AWS D1.1—STRUCTURAL WELDING — — — ■I — CODE—STEEL. O 09/19/16 ISSUED FOR CONSTRUCTION C 09/08/16 ISSUED FOR REVIEW B 06/27/16 ISSUED FOR REVIEW A 05/18/16 ISSUED FOR REVIEW No. Date Revision Client: verizon" 22'x34'SCALE: NOT TO SCALE TYPICAL CONNECTION DETAIL 3 j 11'x17' SCALE: NOT TO SCALE Implementation Team: NEW 2 1/2" SID PIPE x 10'-6' LONG /—NEW 2 1/2'STD PIPE x 10'-6' LONG //°) 1 BLACK ROCK A&E Team: SITEPRO SCX2 CROSSOVER PLATE OR X / 5—4"t 5—4"t / 2 8' • APPROVED EQUAL MORRISON HERSHFIELD EXISTING 2 1/2" PIPE _ iir f 411 EXISTING MOUNT 600 STEWART ST,SUITE 200 (2) 1/2' U—BOLT (2) 1/2' U—BOLTEll FRAME SEATTLE,WA 98101 Tel:206.268.7370 www.mor isonhershfeld.com 2 1/2' STD PIPE \ \ °e 1r� 1 ]1 Project Info: I ��411_______ I�I L �I POR r o NEW 2 1/2'STD TUALATIN r PIPES 6975 SW SANDBURG STREET TIGARD, OR 97223 ■SII \ Drawing Title: t•I 0 k in DETAILS O NEW 2 1/2'STD a in PIPES Project Number: Start Date: t \ \ I �� ) I r o I 7160045 05/03/16 • ° J°I ��I U'I. eLe Ie eI Drafter: Designer: — — LW SV Project Manager: Professional of Record: RKL RL TINGRevision No: Sheet No: .:J I///!/.dill //, i,.{73/i//i//2//,i.-,, i ...,.,./?,EXIS ...iROOF ,,,,,,-1• .,,,,/,1,7,,,,,,,, �il,l.'i•i//i,,,...,,,/, ,, / ,,,,,,..ii.11/;/,i,/T7-I ,i.il / , i,. 0 s- 1 22'x34'SCALE: NOT TO SCALE TYPICAL CONNECTION DETAIL 2 22"x34" SCALE: 3�4W = -0 6 ANTENNA MOUNT MODIFICATION 1 11'x17' SCALE: NOT TO SCALE 1 DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS.NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRTTEN APPROVAL.ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS AND 1/4-20 HEX BOLT SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIELD 2 HOLE LUG / REVIEW ONOR THE F THS�PR ECT.CT WILL BE PROVIDING CONSTRUCTION // SOLID BARED TINNED THE COPPER ��^C D iyo #2 AWG GRN - /-1/4" FLAT WASHER ° O®® r",.,� CONDUCTOR W/ THERMOWELD T(C` ,4 _SII■IA ® ° ` ,F - R 0 B ERT J. �2, ��W�������Alr .AW� °°®®• °®° ®at O / • J1� 3/8"x3/4" SS BOLT ° ®. ° ® " �e4 EXISTING GROUND BAR ° ,°°a®p� I 3/8" WASHER LARA PRIMARY GROUND BAR/ Y 0 '!- License#5897 METAL ENCLOSURE 1/4" EXT. TOOTH LOCK WASHER IJ°� °°® "' LA N T/,I 0 N o. : 4 1/4-20 HEX NUT ' 00i�°I/ 1� 3/8" WASHER .1 e'1J INSTALLATION NOTES: 1. SELECT BOLT LENGTH TO PROVIDE A MINIMUM OF TWO EXPOSED THREADS. 3/8" SS LOCK WASHER F y- _ 2. BURNISH MOUNTING SURFACE TO REMOVE PAINT IN THE AREA OF LUG CONTACT. 3/8" SS NUT SeiJ 16 ZO160 )SI0:i ROBERT JERRY LARA 3. APPLY ANTI-OXIDANT COMPOUND TO MATING SURFACE OF LUG AND WIPE CLEAN EXCESS COMPOUND. REGISTERED ARCHITECT STATE OF OREGON 4. USE SOLID COPPER WIRE AND MECHANICAL 2-HOLE LUG FOR ALL EXTERIOR GROUNDING. OF97 CONSTRUCTION 22"x34" SCALE: NOT TO SCALE NOT USED 6 22"x34" SCALE: NOT TO SCALE GROUND CONNECTION DETAIL 5 12;x17" SCALE: NOT TO SCALE"x34" SCALE: NOT TO SCALE TYPICAL GROUND BAR CONNECTION 4 - - - 11"x17" SCALE: NOT TO SCALE 0 09/19/16 ISSUED FOR CONSTRUCTION PROPOSED ANTENNA C 09/08/16 ISSUED FOR REVIEW MOUNTING PIPE B 06/27/16 ISSUED FOR REVIEW wob A 05/18/16 ISSUED FOR REVIEW No. ,IIIIIII IIINTN,hoo Date Revision Client: PROPOSED PANEL Verizon ANTENNA • Implementation Team: l d0 I-BEAM OR C-CHANNE PROPOSED RRU BLACK ROCK A&E Team: • SITE PRO ANGLE ADAPTER FOR SNAP-INS (P/N #ADAP-0) MORRISON HERSHFIELD 600 STEWART ST,SUITE 200 SEATTLE,WA 98101 PROPOSED CABLETel:206.268.7370 '�- www.morrisonhershfeld.com 411 Project Info: SITE PRO STACKABLE SNAP-IN HANGERS ® 3'-0" 0.C. MAX; CONTRACTOR TO SELECT APPROPRIATE CABLE POR I HANGERS BASED ON CABLE DIAMETER #2 AWG SOLID BARE TINNED I TUALATIN COPPER CONDUCTOR I ) 6975 SW SANDBURG STREET TIGARD, OR 97223 #2 AWG STRANDED UV RATED /I / Drawing Title: CONDUIT COUPLING JACKETED COPPER CONDUCTOR STRAPPED TO UNISTRUT / ANCHOR TO PAD / / / 1. CONDUIT / GRAINGER BEAM CLAMP / (P/N #3KF30 OR / G R O U N DIN G P1000 UNISTRUT alliiii_ APPROVED EQUAL) / / D ETAI LS 1 (12" LONG) (TYP.) 15 C / /JAIME CONDUIT I / • ( Project Number Start Date: r (2) 7/8"0 HILT! KWIK BOLT GRAINGER CONDUIT III EXPANSION ANCHOR W/ HANGER (P/N #6XC40 7160045 05/03/16 1-5/8" MIN. EMBED. OR APPROVED EQUAL) 0 0®(1 Drafter: Designer: EXISTING SLAB 0® °000®® LW SV 0®® o°®® Project Manager: Professional of Record: CONDUIT °00® °000 RKL RL EXISTING ANTENNA °00000° Revision No: Sheet No: 0 SECTOR GROUND BAR — — 0 G- 1 " SCALE: NOT TO SCALE 22"x34" SCALE: NOT TO SCALE NOT USED 3 2 "x17" SCALE: NOT TO SCALE TYP. CONDUIT SUPPORT DETAILS 2 11"xl7" SCALE: NOT TO SCALE TYPICAL GROUNDING DIAGRAM 1 11"x17"SCALE: NOT TO SCALE