Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (169)
F-PraV\c6- V V`o W Fire Protection Services, Inc. _ 9950 SW Arctic Dr [1) 0 Beaverton Or 97005 Phone: (503) 590-3732 Fax: (503) 628-6214 River Terrace East Condos 17077 SW Appledale Road �r Sherwood, Oregon 97140 AUG 2 3 2018 FIRE ALARM DESCRIPTION Cl`1" ‘3-kc;, HD at<!9[.D! G nivIslow DESCRIPTION An automatic fire protection system will be installed utilizing an addressable control panel. This will provide for monitoring of sprinkler control valves, flow switches, a single Pull station in the riser room, and an annunciator keypad at the main entrance. The interior room LF horns will be mounted at 84"to the bottom of the device or on the ceiling. The pull station will be mounted at 48"to the center of the device. All audible devices will sound in the ANSI temporal pattern. Primary power to the panel shall be 110 VAC utility power with a 12VDC 7aH battery back-up. All fire alarm circuits will be wired with 16 gauge Fire Alarm Cable with the exception of NAC circuits, which will be wired with (minimum) 14 gauge Fire Alarm Cable. Monitoring will be provided through Alarm Central Station, A UL Listed Monitoring Company in Beaverton, OR. (503.641.6761) All installation will be done according to NFPA 70 &72 standards. Work will be performed in a neat and professional manner. All work will be performed according to the timeline set. All equipment will be UL listed and approved for the application. SYSTEM COMPONENTS Silent Knight 5820x1 Addressable Fire Alarm Control &Communicator Silent Knight SK Series Smoke Detectors and Heat Detectors Potter PSN 106 Distributed Power Supplies Silent Knight Addressable Relay Modules System Sensor Horn Strobes/ Strobes System Sensor LF Horns POTTERProject Name: River Terrace East Condos Standby Hours: 24 The Symbol of Protection Alarm Mins: 5 PSN-106 Installed By: Batt Efficiency%: 80% Battery& Voltage Drop Designed By: Calculations Date: 8/23/2018 NAC Source Voltage: 20.4 • Model#: PSN-106 Max Panel Current(amps): 10 Panel ID: 'MUser assumes all responsibility to ensure the quantities and current Location: draw values in this worksheet are accurate prior to submittal. dPanel Standby(amps) Alarm(amps) Qty Part# Description Each Total Each Total 1 PSN-106 NAC Power Expander 0.075 0.075 0.075 0.075 Panel Standby: 0.075 Panel Alarm: 0.075 NAC Circuits(See NAC Configuration below) Standby(amps) Alarm(amps) Ckt Use Description Total Total 1 0.00000 1.21200 2 0.00000 1.21200 3 0.00000 2.17800 4 0.00000 2.17800 5 0.00000 0.00000 6 0.00000 0.17600 AUX 0.00000 0.00000 NAC Standby: 0.00000 NAC Alarm: 6.95600 Battery Calculation Summary Standby(amps) Alarm(amps) Panel Current: 0.07500 0.07500 NAC Circuit Current: 0.00000 6.95600 5 Total Standby: Total Alarm: Standby Hours: 24 Alarm Mins: 5 AH Required: 1.80 AH Required: 0.59 Total Combined Standby&Alarm AmpHours Required: 2.39 Efficiency Factor: 80% Required Battery AmpHours: 2.99 Battery AmpHours Provided: i j. u Potter Electric Signal(C)2011 1 of 5 PSN-1000(E)Battery and Voltage Drop Calculation 4. QPorrER riwsi.eneraPodectwn NAC Circuit Configuration& Voltage Drop River Terrace East Condos 8/23/2018 .NAC 1 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: i a Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL Min Volts Req'd r I #14 Solid 2.5 0.000 1.212 20.40 16 t, `.Circuit Devices - Standby(amps) Alarm(amps) Qty Lookup Type Description Each Total Each Total 8 User Defined System Sensor H-LF Low Freq.Sounder 0.000000 0.000000 0.138000 1.104000 2 User Defined System Sensor L Series Horn Strobe Wall 0.000000 0.000000 0.054000 0.108000 i Total Standby: 0.00000 Total Alarm:i 1.21200 NAC 2 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: j. i Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL Min Volts Req'd '(' #14 Solid 2.5 0.000 1.212 20.40 16 Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Description Each Total Each Total 8 User Defined System Sensor H-LF Low Freq.Sounder 0.000000 0.000000 0.138000 1.104000 2 User Defined System Sensor L Series Horn Strobe Wall 0.000000 0.000000 0.054000 0.108000 Total Standby: 0.00000 Total Alarm: i T (i. )Et Potter Electric Signal(C)2011 2 of 5 PSN-1000(E)Battery and Voltage Drop Calculation is a i ['OTTER ,„s mt.si Profaotroa NAC Circuit Configuration& Voltage Drop(coned) River Terrace East Condos 8/23/2018 - NAC 3 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 . Usage: Description: Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL Min Volts Req'd #14 Solid 2.5 0.000 2.178 20.40 16 Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Description Each Total Each Total 15 User Defined System Sensor H-LF Low Freq.Sounder 0.000000 0.000000 0.138000 2.070000 2 User Defined System Sensor L Series Horn Strobe Wall 0.000000 0.000000 0.054000 0.108000 Total Standby: 0.00000 Total Alarm: NAC 4 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL Min Wilts�Req'd #14 Solid 2.5 0.000 2.178 20.40 16 Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Description Each Total Each Total 15 User Defined System Sensor H-LF Low Freq.Sounder 0.000000 0.000000 0.138000 2.070000 2 User Defined System Sensor L Series Horn Strobe Wall 0.000000 0.000000 0.054000 0.108000 1 Total Standby: 0.00000 Total Alarm: i I Potter Electric Signal(C)2011 3 of 5 PSN-1000(E)Battery and Voltage Drop Calculation POTTER RgspmtmrofP.o t,,. ' NAC Circuit Configuration& Voltage Drop(cont'd) River Terrace East Condos 8/23/2018 i NAC 5 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: j,a Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL Min Volts Req'd #14 Solid 2.5 0.000 0.000 20.40 16 Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Description . Each Total Each Total --IIII III -Ell NI --_ IIIII - -- - -- Total Standby: 0.00000 Total Alarm: 0.00000 4; NAC 6 MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 Usage: Description: j Wire Type, Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ EOL Min Volts Req'd #14 Solid 2.5 0.000 0.176 20.40 16 ' " Circuit Devices Standby(amps) Alarm(amps) Qty Lookup Type Description Each Total Each Total Q User Defined System Sensor L Series Outdoor Horn Str 0.000000 0.000000 0.176000 0.176000 NI - -__- -IIII 111. --- _--_ - - i. Total Standby: 0.00000 Total Alarm: 0.17600 1 i AUX Power MAX Circuit Current(amps): 3 Source Voltage Used(VDC): 20.4 1 1 Usage: Description: Wire Type Ohms/1000ft Length 1-Way Actual Ohms Max Load(amps) Volts @ Last Device Min Volts Req'd #14 Solid 2.5 0.000 0.000 20.40 16 Circuit Devices Standby(amps) Alarm(amps) tAtt Qty Lookup Type Description � Each Total Each Total y i Potter E ectric Signal(C)2011 4 of 5 PSN-1000(E)Battery and Voltage Drop Calculation t \ t f \ Total Stakby 0.00000 r alAl m: 0.00000 \ \ 1 t E 1 1 ) ) } Potter Electric Signmc, o 5 of 5 PSN-1000(E)Battery and Voltage Drop Calcula_ INTELLIKNIGHT FIRE ALARM CONTROL PANEL SILENT IntelliKnight® Model 5820XL KNIGHT Addressable Fire b Honeywell Alarm Control System Y YW The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface - .. module (for printing system reports), and 5895XL intelligent . power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol • Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • Built-in synchronization for appliances from AMSECO®, • 6 amp power supply and maximum Gentex®, Faraday, System Sensor, and Wheelock® charging capacity of 35 amp hours (An additional cabinet enclosure is required for • FlexputTM I/O circuits batteries in excess of 18 amp hours) • Supports Class B (Style 4) and Class A(Style 6) configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • Built-in annunciator with 80-character LCD display The 5820XL can be surface or flush • RS-485 bus provides communication to system accessories mounted • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit (SLC) uploads/downloads supports multiple device types of the same • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK (System Sensor) • Plex-1 door option combines a dead front cabinet door with a SD clear window, limiting access to the panel while providing • single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FAC P. INTELLIKNIGHT FIRE ALARM CONTROL PANEL t IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel - Indicator Lights 5820XL features a 6 amp power supply required to start a new system.The General Alarm (Red): Flashes when in and maximum battery charging built-in keypad and 5860 remote alarm; solid when alarm silenced capacity of 35 amp hours.An additional annunciator give on-site access to all cabinet enclosure(PN RBB) is required programming.You can also program Supervisory(Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when Flexput circuits on 5820XL control can Software Suite,which is Windows°- supervisory silenced be individually programmed to function based software. System Troubles(Yellow): Flashes as notification circuits, auxiliary power ) when a trouble condition exists; solid outputs,or initiation circuits that Built-In Digital Communicator when trouble silenced support both 2-and 4-wire smoke detectors. 5820XL features a built-in UL listed c System Silenced (Yellow): On when an digital communicator for remote The 5820XL system operates on non- alarm, trouble or supervisory condition reporting of system activity and system twisted, unshielded cable when wired has been silenced but not yet cleared in compliance with standard wiring programming. The communicator has System Power(Green): Flashes for AC practices as called out in the National the ability to seize two telephone lines failure; solid when power systems are Electric Code 760-51 specifications for to report alarms and troubles to a normal power-limited fire protective signalling monitoring facility.The communicator cables. No special wiring is required. supervises two phone lines and will System Application 5820XL provides 13 preset notification activate a trouble signal if a line failure Y Pp is sustained for more than 45 seconds. 5820XL has one built-in signalling line cadence patterns (including ANSI 3.41) Other communication features include: circuit(SLC)which supports multiple and four user programmable selections retry if communication fails,two phone devices dependent on protocol being for fire alarm notification. number capability,download phone used.Three additional loops can be Two programmable general purpose number capability and Touch-Tone or added using the 5815XL SLC Form C relay outputs are provided on rotary dialing.The communicator is expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco Additionally,the IntelliKnight system Contact ID.The format is selectable by The 5820XL SLC loops support features a built-in walk test and auto- account number. multiple device types, including: programming. Its innovative, dead front • Addressable photoelectric smoke cabinet design allows for flush or detector surface mounting. System maintenance 7miro • Addressable ionization smoke is easy to perform. , , Willa detector U AIM User Interface • Addressable heat sensor The 5820XL built-in annunciator with • Addressable duct smoke detector 80 character LCD display and largeO, . rit` 'a Tar • Contact module easy-to-use tactile touchpad can be at r . r • Relay output module used for system operation, :it, t programming and maintenance. It has fir= • Addressable notification module five LEDs for alarm, supervisory, • Addressable beam detector(SK system trouble,system silenced and protocol only) system power. System operations • Addressable multi-criteria smoke include silencing alarms and troubles, Approvals detector(SK protocol only) resetting alarms and the display of NFPA 13, NFPA 15, NFPA 16, alarm troubles and memory.The NFPA 72: Central Station; Remote • Addressable multi modules(SK system's non-volatile event history Signalling; Local Protective Signalling protocol only) buffer stores 1000 events for viewing Systems;Auxiliary Protected Premises The following advanced sensor from the built-in or remote annunciator. Unit; &Water Deluge Releasing capabilities are available with 5820XL: System operation can be initiated with Service. Suitable for automatic, , a mechanical firefighter's key or a valid manual,waterflow, sprinkler ', • Automatic drift compensation 4-to 7-digit operator's code. p • Maintenance alert supervisory(DACT non-coded) ( Programming signalling services. • Built-in sensor test to comply with The IntelliKnight system offers several Other Approvals: UL Listed; NFPA 72 calibration testing options to simplify and speed up CSFM 7170-0559: 135; requirements programming.The JumpStart®feature MEA 429-92-E Vol.VI; FM Approved minimizes programming IINTELLIKNIGHT FIRE ALARM CONTROL PANEL F i IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel 1 IntelliKnight 5820XL """� Facws ility Addressable Fire Alarm System Management Software SK(System Sensor) Protocol Devices dndows Based Up/Download Software I H Compatale CS _ .. .WI Receiver L._...,,_....., • emotion I --� 5820X1. SK-2/2UD Connectrtemetieon lfisorAlarm IP Communicator 5605X1. -111, v�rUenr am�rM,dlke 3 Pam CPeayr 1 !7 =son'FM.avr + 4111 I __I ' Kept PliliY.r o A Ai.: , INearlsn a�q�a�cc ii in`e1 i 5815XL B es-aa: Ste Fxaerder es 5860 5824 y -:omoto Arable cocr Prrtor.'c >nw MCAu4 ♦. ,y +& ]IYells Marc S,a) * �, -. 6 Flezput' 7 .w -;as 1' y'` PO Circuits ' 815XL I Can be inputs I C F4'_urle ie Ofoutpute_.. :. o W 6 FIenpCIrdits t' 5 y S can be Inputs r'' I .÷.....J or outputsv 3 le p< eets.arhohes Hans a07 Nast: S . „ ,.:.:: F;S'T..nm - Maliwl t ♦♦ 1111. IO 0 * SK4 SK 3 rdtor SKaso SK Conhol-a SK I rol B200SR SK,Acdlmate SK.2aa-6 T” A PAdr(ue,ro Adf vitas Fault Gelehf .NI.alcwoil Su7emsad �ounda Mutrstera Zero •-�_ .-,.1 eteacr Modco M.MUIa NI.We mcoue at, I_�_ oioctc I'Me'llo n raw DftertQ Noble T01F0 Mctlae detector HOLO ,Zerr,e Ar nun seta Pit t' l 116# . iiiit �/ W 1 SK-Photo SK4SoNror-2 SKRelaymon-2 S(-Heat B224RB 822481 B210LP SKPttotO-T :I al Montx AdSes,att_ SK-HeatROR Seta/ este:r Reedit III 5680 1 P hh~,soba. M:dine Dus Maiiicr SK-Heat-HT Za a ""e ea_E LE"7rwe,& I FtDeteltanc Wlrwn Re»+s eat _ode Fll I'ItiU ModlEDaectl hk'tt deei'ass ir• Imo. il* 111111 ( 4 11111 I I I 5883 Pena lir f...Mo.ul+ SK-Beam SK1abn-10 SK-Pul-DA SK-Duct SK-Mrlimon SKRelay-8 SK-Zone SK-Relay BK.Beam•T Ad.ia,;^tlo SK-Pull-SA Ad73otlo M:rler Pew(On! Adtesaatia Adi0000tir I ACCratdhle M, nr, P.LI«.,n:ae Dui t1I UIf McCue mceas=e Palsy Daamrbtn.Yo. Mahle Pit Salon Doane Mehr Modv'<e 011:11 e 5865-4 or 5165-3 �' Use the 5880 to control u to 4 1 -mAmuncirto- d -_� (:aS-041wn; 1 5883 Relay Interface Modules ' 1 INTELLIKNIGHT FIRE ALARM CONTROL PANEL 5 IntelliKnight Model 5820XL - Addressable Fire Alarm Control Panel Specifications S-BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz, 2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using Total Accessory Load: 6A @ 27.4 VDC, and 5860R is red. a PC. Upload and view panel account power-limited 5815XL Signal Line Circuit Expander information, event history, and detector 1 Standby Current: 215 mA The SLC expander is used to add more status. iAlarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system. 5820XL supports three (SKSS) Flexput Circuits: 5815XL's. Each 5815XL can support 99 Powerful end-user facility management t Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector programmed individually as: 127 SD devices. status and event history via modem or Notification circuits: 3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power, 6 Flexput I/O Plex-1 Auxiliary power circuits: 3A @ 27.4VDC circuits and 2 Form C relay circuits to a Dead front cabinet door with clear per circuit, power-limited 5820XL system. window to limit access to the FACP. Initiation Circuits: 100 mA @ 27.4VDC 5496 Intelligent Power Module RBB per circuit, power limited A 6 amp notification power expander Remote battery box accessory cabinet. that provides four power-limited notifi- Use if backup batteries are too large to Physical cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 5880 LED/lO Module 16"W x 10" H x 6" D 14.5"W x 24.75"H x 3.9"DFeatures 40 LED outputs, 8 normally (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs, and one piezo SD505-DTS-K output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR. Provides remote key 16.2"W x 26.4"H x 4.2"DRemote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) Features 30 programmable LED (15 of detector alarm. red and 15 yellow)outputs, and a piezo SD and SK Devices 1a Weight: 28 lbs. (12.8 kg) sounder.The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7.0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet. Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log FCC Part 15 and Part 68 approved of system events,detector status Type of Jack: RJ31X(two required) reports, and event history. Interfaces with building control system. i This document is not intended to be used for installation purposes.We try to keep our SILENT Made in America KNIGHT product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472 PN 350210 Rev H2 by Honeywell Phone:(203)484-7161,Fax:(203)484-7118.www.silentknight.com. ©2012 Honeywell International Inc. IntelliKnight&JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight INTELLIKNIGHT ACCESSORY 10 SILENT 5860 Remote Annunciator KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility Now you can operate and program your IntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. I For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description • Available in red or light gray Features include an 80-character • Support for simultaneous use of backlit LCD providing easy-to- multiple 5860s understand system messages. The • RS-485 interface to panel -..-- annunciator is ergonomically • Operation and appearance is ----- designed with over-sized buttons identical to 5860 built-in –..for the most frequently used annunciator :W_ : �S°•` features, like Reset and Silence. • On-board piezo sounder audibly - ':.tint► indicates alarms, troubles, and ,.. • In addition to status messages supervisories ..• displayed on the LCD, there are . Five status LEDs for alarm, five LEDs for alarm, supervisory, supervisory, trouble, silence and trouble, silence, and AC power AC power conditions status. 5860 • Wiring lengths up to 6000 ft. from The annunciator is available in gray the FACP (depending on wire Environmental to match virtually any decor and gauge and number of devices on Operating Temperature: 32°F– red for applications where the SBUS) 120°F (0°C–49°C)• annunciator must stand out. The UL listed, complies with NFPA 72 Humidity: 10%–93% non- annunciator 1 enclosure can be • CSFM approved condensing 1 surface or flush mounted.A trim Electrical Specifications Compatibility ring kit is available for surface Operating Voltage: 24 VDC The 5860 is compatible with the mounting. Standby Current: 20 mA max following FACP's: Features Alarm Current: 25 mA • 5820XL Addressable Fire Control • 80-character backlit LCD display Wiring Distance: 6,000 max. from Panel (4 lines with 20 characters on FACP (depending on wire gauge • 5820XL-EVS Fire Control Panel each line) and number of devices on the with Emergency Voice System • Tactile and audible feedback SBUS) • 5808 Addressable Fire Control • Accepts user codes or fire Panel fighter's key Mechanical Specifications • Larger keypad buttons for system Physical 9.1"W x 7.4" H x 1.5" D • 5700 Addressable Fire Control reset and silence (23.1 W x 18.8 H x 3.8 D cm) Panel • Install up to twelve 5860s per Shipping Weight: 2.8 lbs (1.3 kg) 5820XL/EVS or 5808 system Color • Install up to eight 5860s per 5700 5860R: Red PN 350224 Rev G C'=. system ©2014 Honeywell International Inc t 5860: Gray I t IE X INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to 12 remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator.All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of.040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP 0.4 *44 SBUS40= 5860 5860 5860 • Up to 12 5860s Per IFP-100/ECS or IFP-1000/ECS System •Up to Eight 5860s Per 5700 System Compatible IntelliKnight FACP Listings Ordering Information NFPA 72; UL Listed; 5860R Remote Annunicator four line LCD CSFM 7170-0559: 135; annunciator with 20 characters per line. MEA 429-92-E Vol. IX; Red FM Approved 5860 Remote Annunciator four line LCD annunciator with 20 characters per line. Gray Accessories 5860TR Red Trim Ring for surface mounting 5860TG Gray Trim Ring for surface mounting SILENT This document is not intended to be used for installation purposes.We try to 15 keep our product information up-to-date and accurate.We caall Ni KNIGHT specific applications or anticipate all requirements.All specificationsnnotcover are subject to change without notice.For more information,contact Silent Knight by Honeywell 12 Clintonville Road, Northford,CT 06472-1610.Phone:(800)328-0103, • Fax:(203)484-7118.For Technical Support, Please call 800-446-6444. mommeamemonomAssembled www.silentknight.com in America 1 P POTTER PSN SERIES ® The Symbol of Protection POWER SUPPLY UL,cUL,CSFM Listed • PSN-64 has 6 amps regulated with 4 Outputs • PSN-106 has 10 amps regulated with 6 Outputs !,, • Outputs Rated at 3 amps maximum each 0 , • _ • May be configured as up to three class"A"Style"Z"notification circuits 5 lig • 3 amp,24 VDC programmable output power 1111 • Supervised Battery Charger:27.3 @ lA(supports 7-55 AH batteries) • Easy to install cabinet with leveling mounts and key lock • Wiring knockouts provided on sides and top of cabinet X • Two Trouble Relays(5A at 30VDC) General System Trouble(programmable for AC delay) 1. Low AC Trouble with optional delay settings • Diagnostic LED's patent pending Status LED's for Active NAC and NAC trouble conditions Status LED's for Earth Fault(Amber),AC(Green),Battery Fault(Amber) • Trouble Memory feature captures troubles which have previously restored CCUS g • Synchronized notification appliance circuits LISTED Potter/AMSECO®,Wheelock®,Gentex®,System Sensor® S2930 7315-0328:0189 • Configurable output circuits(DIP switch sets options for each circuit) • 15 mA at 8-33 VDC input trigger Product includes a 5 year warranty • Reference EOL allows 2K—27K EOL value to be used • Quadrasync provides panel wide synchronization of same or multiple brands Dimenions: 16 1/8"W x 16 3/4"H x 3 1/2"D • PassThru mode allows the Outputs to match the Input Signal Electrical Specs: Stock Number:3006436 PSN-64 Red Enclosure • 120/240 VAC 50-60 Hz input 3006437 PSN-106 Red Enclosure • 5.1 Amps @ 120 VAC or 2.5 Amps @ 240 VAC 3006446 PSN-106 Black Enclosure • Standby Current 60 mA • Alarm Current 200 mA* *no external load Description 1 The PSN series of notification power supplies offers reliable notification Sensor®strobe devices.Each output can be configured the same sync power with unprecedented versatility.The power supplies offer either protocol or set independently. 6 or 10 amps of continuous power through 4 or 6 outputs respectively. In addition,the panel has an input PassThru mode allows the outputs 1 Each output is rated at 3 amps and it may be used continuously without to follow the input signal and sync up the input flash.The panel will r any derating. recognize the type of input being supplied and pass this through to the The power supply operates on either 120 VAC or 220 VAC power input outputs with the same pattern.This input pass through can be selected and has a regulated 24 VDC output.In addition,the panel can charge on each output independently. up to 55 AH batteries and leads the industry in housing up to 18 AH The power supply contains simple dipswitch programming and LED batteries.The cabinet is constructed out of 18 gauge cold rolled steel and indications providing the installer indications of the operation and the has a durable red powder coat finish.In addition,a key lock is provided ability to correct any faults.A Trouble Memory is provided to allow an 1 for securing the door.Ample electrical knockouts are provided on the installer to review past troubles and make the necessary repairs.Each sides and the top,allowing the installer options for running wires and output has an LED to pin point the exact circuit where a problem may maintaining the correct separations. have occurred.Relays are provided for monitoring the general system The power supply offers an industry leading Quadrasync function that and AC failure. allows for multiple strobe circuits of different brands to be synchronized Each output and be independently configured for various applications to flash at the same time.The panel can have four different brands each and installations.Each output can be independently configured for Class connected to its own circuit and all of the strobes flash together. A or Class B operation,constant power,ANSI Temporal Code 3,Single, Each output can independently be configured to provide one of Multiple or Combo Inputs or Door Holder Power. four synchronizations or steady power. This provides unequivocal flexibility in new and retrofit installations.The panel can be configured to synchronize Potter/AMSECO®, Gentex®, Wheelock® and System Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service: 866-240-1870•Tech Support: 866-956-1211 •Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8910013-REV C2 PAGE 1 OF 2 11/12 P POTTER PSN SERIES f e The Symbol of Protection POWER SUPPLY ,t PSN-106 Wiring Diagram g° 120/240 VAC GND FAULT N_' Jumper Position DETECT ENABLE ^ ON -7 OFF 120VAC 50Hz-60Hz 240VAC 50Hz-60Hz Black Connect to separate White unswitched AC circuit Ground status LED'sei _ 40A• ---------------------- NAC1 NAC2 NAC3 NAC4 NAC5 NAC6 DC PWR 'S7 'S8. _: e" ]ABABOlyi] ITI.I. HPI — r ❑ o o BBA9B+s, H N /� COMM• Fusse l 1 In�� II I o]AA9A6Aisz i 0( 7 l roilEl o LI.I.J.I S3 i, ❑ ° o I t ❑ 0 a I U [x:71 IIREI As4 Factory Installed 0 ❑ ❑ o Interconnect. • AC Power 0 II HHPllis5 gm Low Battery Gnd Fault I I Comm 0 HI+I'il'Pjs6 8 O ❑ O Bulk Options 7,7!7^••7. 77, 7777 .►fin - I 0 0 ]NACI NAC2 NAC3 NAC .'C5 NAC6 P REF 1 IN2 O LOW ac nouwa - + - + - + - + + - + - + cnr. - F.OI - +FOI. NC COM NO NC COM NO Battery+ .._..�........_._�/ o Battery- Common relays are Optional E.O.G. non-power limited. R Reference E.O.L. E.O.L. DC Power Trigger Battery connection(non-power limited). Note:PSN-64 and PSN-106 draw 15 mA when polarity reverses and the power 11i Use two(2)i2V batteries connected in series. supply is triggered.There is no current draw in Standby Mode. .1 i Engineering Specification The contractor shall supply and install the Potter PSN power supply.The assemblies.The LEDs shall have distinct flash patterns to provide further power supply shall operate on either 120 or 240 VAC input.The panel indication ofthe troubles present.The panel shall have selectable Trouble shall be capable of continuous load power without any degradation to Memory to provide the installer an indication that a past trouble existed the main supply or the distribution board.The cabinet shall be capable of on a circuit for diagnostic purposes. housing up to 18 AH batteries and the panel shall be capable of charging Each output ofthe power supply shall be capable of 3 amps of continuous up to 55 AH batteries in an external cabinet. power without degradation over time.The power supply shall provide for The panel shall have dip switches for simplistic configuration of the multiple circuits of strobe appliances.The power supply shall synchronize 1; system and LEDs to provide visual indication to the installer of the status the flashes of any of the above listed strobe appliances on a per circuit ]' of the system.The dip switches shall allow for AC power delay selection, basis.Up to four different strobe circuits may be connected and all of i, A Class A/B operation per output,Door Holder Power options,constant the strobes shall flash in unison as required by UL 864.In addition to auxiliary power,trigger input type,ANSI Code 3 Temporal Code,Pass this Quadrasync feature, the panel shall allow any of the four above r Thru(input tracking),Potter/AMSECO®sync,Gentex®Sync,System mentioned sync patterns as an input and pass this signal through and Sensor®Sync or Wheelock®sync.The LEDs shall provide indication synchronize the outputs to match the input flash pattern. of communication between the power supply and distribution circuit PRINTED IN USA MKT.#8910013-REV C2 PAGE 2 OF 2 11/12 INTELLIKNIGHT ACCESSORY T 4% SILENT SK-Photo, SK-Photo-T KNIGHT and ) SK-PhotoR by Honeywell Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight • IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. I Description • Optional remote LED annunciator (System Sensor®PN RA100Z) r 5 SK-Photo and SK-Photo-T are plug-in w rg m ,e , , p g Plug-in mounting provides ease of , type smoke sensors that combine a installation ,. �`* photoelectric sensing chamber with • Tamperproof feature available on addressable analog communications. mounting bases Point ID capability allows each ,* detector's address to be set with rotary • Listed for use in duct applications :::1z::v ,\I" ,. address switches, providing exact • Rotary address switches for fast detector locations for selective installation maintenance when chamber • UL Listed N contamination reaches unacceptable • FM ApprovedAVM levels. SK-Photo and SK-Photo-T have a Specifications ''''" unique optical sensing chamber that is Physical . „r,,,, ,ohm ;.„ engineered to sense smoke produced Height: 2.0” (5.0 cm) SK-Photo (Base included) by a wide range of combustion Diameter:4.1"(10.4 cm) installed in sources. In the SK-Photo-T, dual B501 base electronic thermistors add 135°F(57°C) Installation thermal technology to maximize Electricals: detection. Operating Voltage: 15-32 VDC The SK-Photo and SK-Photo-T plug Standby Current: into a compatible IntelliKnight-series The SK-PhotoR is a remote test detector base.The SK-PhotoR is a capable detector for use with the 300 pA @ 24 VDC Maximum remote test capable detector head DNR/DNRW duct smoke detector. (not Alarm Current: 6.5 mA @ 24 VDC max included within the DNR(W)duct included) (with LED on) smoke detector. Environmental Operating Temperature Compatibility Features SK-Photo: 32°—120°F ° ° 0C—49C (0°C 49°C) SK-Photo, and SK-Photo-T are • Sleek, low-profile design SK-Photo-T: 32°—100°F(0°C—38°C) compatible with the following detector • Base included Humidity: 10%—93% non-condensing bases: • Reliable analogcommunications for Other Ratings B5 B501 6"base (included) 2 wire base trouble-free operation SK-Photo-T Thermal: Fixed B224RB Relay base • Age resistant polymer housing temperature set point 135°F (57°C) B224B1 Isolator base • Dual electronic thermistor design on Velocity: 0—4000 fpm (0—20 m/sec) B200SR Sounder base the SK-Photo-T The SK-Photo, SK-Photo-T, and SK- • Superior EMI resistance for reliability PhotoR are compatible with the • Simple field cleaning for code following IntelliKnight FACPs: compliance 5820XL • Variety of mounting options to meet 5820XL-EVS any application 5808 • Dual LED indicators for 360°visibility 5600 5600(Rev 2.0 or higher) • Detector transmits signal to indicate maintenance is required `€ i ' INTELLIKNIGHT ACCESSORY Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors - Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B210LP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. I `r SLC IN OUT // div Compatible FACP RA100Z(Optional) MI MI F1.1 ii �r iu ter_ e,,,,,,,\iv 1.. • %;10 \iiiiiii 1 Class A Optional Wiring / Wiring SK-Series Detector Mounting Bases SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350118 Rev E subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com 1 i INTELLIKNIGHT ACCESSORY - SILENT SK-Heat, SK-Heat-HT KNIGHT and SK-Heat-ROR by Honeywell Addressable Thermal Heat and Rate-of-Rise Detectors The SK-Heat, SK-Heat-HT, and SK-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with Silent Knight IntelliKnight series Fire Alarm Control Panels (FACPs). IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight r panel recognizes each detector by its specific address, so precious seconds are not wasted in determining +'. location of an alarm. Description • Detector transmits signal to SK-Heat, SK-Heat-HT and SK- indicate maintenance is required Heat-ROR are intelligent sensors • Plug-in mounting provides ease that utilize a state-of-the art of installation thermistor sensing circuit for fast • Optional remote LED annunciator response. Sensitivity is (System Sensor®PN RA100Z) `' continuously monitored and • Tamper-proof feature available on reported to the FACP. Point ID mounting bases capability allows each detector's address to be set with rotary • Rotary address switches for fast address switches, providing exact installation SK-Heat(base included) detector locations for selective • UL Listed SK-Heat-ROR: Rate-of-rise maintenance when chamber detection 15°F/min 8.3°C/min contamination reaches Specifications ( ) unacceptable levels. Physical Compatibility i SK-Heat is a fixed tem erature Height: 2.0" (51 mm) p Diameter: 6.1" (155 mm) installed The SK-Heat, SK-Heat-HT and SK- sensor that uses a thermistor Heat-ROR are compatible with the sensing circuit to produce 135°F in B210LP base p. followingdetector bases: Shipping Weight: 4.8 oz (137 g) (57°C)fixed temperature alarm. Electrical B210LP 6" base (included) SK-Heat-HT is a variable high B501 2 wire base temperature detector that provides Operating Voltage: p 15 to 32 Volts DC Peak 822481 Isolator base high temperature detection at B224RB Relay base 135°F - 190°F. (57°C - 88°C) Standby Current: B200SR Sounder base 300pA @ 24 VDC SK-Heat-ROR is a rate-of-rise The SK-Heat-HT and SK-Heat- temperature sensor with 135°F LED Current: 6.5 mA@ 24 VDC ROR are compatible with the (57°C)fixed temperature alarm. Environmental following IntelliKnight FACP's: Features Operating Temperature 5820XL SK-Heat& SK-Heat-ROR: 5820XL-EVS • Reliable analog communications -4°— 100°F (-20°C—38°C) 5808 for trouble-free operation 5700 • Age resistant polymer housing SK-Heat-HT: -4°— 150°F (-20°C—66°C) The SK-Heat is compatible with the • Innovative thermistor sensing following IntelliKnight FACP's: circuit Humidity: 10%—93% • Superior EMI resistance for noncondensing 5820XL 5808XL-EVS reliability Thermal Ratings 5808 • Variety of mounting options to SK-Heat: Fixed temperature alarm 5700 meet any application 135°F (57°C) 5600 (Rev 2.0 or higher) • Dual LED indicators for 360° SK-Heat-HT: High temperature heat visibility sensor 135°F - 190°F (57°C- 88°C) P/N 350120 Rev. F ©2016 Honeywell International Inc. INTELLIKNIGHT ACCESSORY Model SK-Heat, SK-Heat-HT, SK-Heat ROR Addressable Thermal k and Rate-of-Rise Thermal Detectors ,i Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent Thermal Sensor Silent Knight Model SK-Heat, SK-Heat-HT or SK-Heat-ROR. The base included shall be B210LP. The Heat detector shall have a flashing status LED for visual supervision. When the detector is activated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required.Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. � J SLC IN OUT i lId ;Y�, Vis, i Compatible FACP coI:aura:a RA100Z(Optional) .lIw ¼e x11.. 41 / A Class A Optional Wiring / li Wiring SK-Series Detector Mounting Bases Accessories M02-09-00-Test Magnet with Telescoping Handle. RA100Z-Remote LED Annunciator. XP-4-Extension Pole for XR2B. Extends from 5—15 ft. RMK400-Recessed Mounting Kit.Provides low profile for use with T55-127-000-Detector Removal Head. 8501. XR2B-Detector Removal Tool.A removal and re-placement tool for BCK-200B-Black Detector Kit.For SK-series detectors. SK plug-in detectors. Includes the T55-127-000. *Unless otherwise noted,specifications apply to all SK thermal M02-04-01 -Replacement Test Magnet. detectors. This document is not intended to be used for installation purposes.We try to keep our product information up-to- SILENT date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are NI KNIGHT subject to change without notice.For more information,contact Silent Knight 12 Clintonville Road Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118.For Technical Support,Please call 800-446-6444. by Honeywell www.silentknight.com } INTELLIKNIGHT ACCESSORY 414SILENT SK-Pull-SA and SK-Pull-DA 1 KNIGHT Intelligent Pull Stations by Honeywell The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual FIRE action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent KnightPULL 1' DOWN 1' Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition ,,,E,,, • Dual-color LED is visible through handle of station blinks a green to indicate normal operation and remains steady red r, in an alarm condition SK-Pull-SA • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks I E • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG)controls and operating mechanisms 1 PUSH IN guidelines (Section 4.1.3[13]) PULLDOWN • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® n} Z • Reliable analog communications for trouble-free operation • Braille text on station handle SK-Pull-DA • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled p y The SK-Pull-SA Th and SK-Pull-DA are compatible • Rotary address switches for fast installation with the following IntelliKnight FACP's: 5600 • UL Listed, including UL 38, Standard of Manually Actuated 5700 Signaling System 5808 5820XL 5820XL-EVS INTELLIKNIGHT ACCESSORY Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications 4 The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight i. model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. t--,-r44].<_ _... ......_..._ Class A IN 4...: SLC + OUT '" Class B Compatible FACP PLlip ! ton: k1 1 [ 1 t Class A Wiring:..-....-.... Class 8 Wiring: — ii 1 ata , Wiring SK-Pull-SA&SK-Pull-DA Pull Stations Specifications Electrical Physical Operating Voltage: 15-32 VDC Height: 5.5"(14 cm) Average Operating Current(LED flashing): 300 pA Width:4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32°— 120°F (0°C—49°C) Bi-Colored LED: Humidity: 10%—93% non-condensing Blinking Green: Normal } Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST)normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-I/O Surface backbox SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover NIGIT all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent FORM#350135 Rev C Knight 12 Clintonville Road, Northford,CT 06472-1610 ©2013 Honeywell International Inc. by Honeywell Phone:(800)328-0103,Fax:(203)484-7118.For Technical Support, Please call 800-446-6444. www.silentknight.com I INTELLIKNIGHT ACCESSORY 0 SILENT SK-Relay KNIGHT Intelligent Relay Module by Honeywell The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built in rotary switches. For more information about the IntelliKnight system, or to locate you nearest source, please call 800-328-0103. Description The SK-Relay is an addressable relay module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). ss The SK-Relay allows a Silent Knight FACP to switch ��;;,tki� � discrete contacts by code command. The relay contains w \ \ \k 4 a \\ ppV�\ w .\� two isolated sets of Form C contacts, which operate as a ������ a�����e °� �'�� �,� w y \` : DPDT switch. No supervision is provided for the notification appliance circuit. ,vokr � > � \` The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK- SK-Relay Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls Installation the SK-Relay, the relay is triggered by the FACP. The SK-Relay mounts directly into a 4" square electrical box. The box must have a minimum Features depth of 2-1/8".A surface mount electrical box • Two sets of Form C contacts (System Sensor® PN SMB500) is available from • Rotary address switches for fast installation Silent Knight • Contacts are rated for a variety of amps (see Specifications) Compatibility The SK-Relay is compatible with the following • Panel controlled status LED that flashes green in IntelliKnight FACP's: normal state and is solid red in alarm 5820XL 5820XL-EVS • Relay programming is completely flexible—can be 5808 mapped to zone conditions 5700 5600 (Rev 2.0 or higher) • Polling LED visible through the cover plate • Attractive ivory cover plate • SEMS screws for easy wiring P/N 350127 Rev E • UL Listed ©2015 Honeywell International Inc. INTELLIKNIGHT ACCESSORY Model SK-Relay Intelligent Relay Module I t To Next Device — 4 If Any Wiring to Terminals 3—9 is Not Power + 4 Limited,the CB500 Barrier is Required.The CB500 Includes a Non-Power Limited Label, n n Which Must Be Placed Over the Power Limited O o o Terminal Information on the Name Plate Label. Q Relay Common 1:: 1 a .`.. 0 ■i Normally Closed 2 i • t�) I ,11,!-: Normally Open 2 i0i 7, '• 2,b,3:9 Relay Common 1 i; i • a ''6'.) I — From Compatible FACP ii •a,�t, + or Previous Device Normally Closed 1 i Module Does Not Supervise C1 O ° O /'1 Normally Open 1 Controlled Circuits v (/1 U U 1 W Wiring the SK-Relay Module Specifications Ordering Information Physical SK-Relay Relay Module 4.675" H x 4.275" W x 1.4" D Shipping Weight: 6.3 oz (196 g) Accessories SMB500 4" Square Surface Mount Electrical Box Environmental Operating Temperature: 32°F— 120°F (0°C—49°C) CB500 Module Barrier Humidity: 10% —93% non-condensing Electrical Operating Voltage: 15—32 VDC Relay Contact Ratings End-of-Line Resistance: Not used 3.0A @ 30 VDC resistive , SLC Standby &Alarm Current: .255mA max © 24 0.9A @ 110 VDC resistive VDC (one communication every 5 sec with LED 0.9A© 125 VAC resistive , enabled) 0.5A @ 125 VAC inductive (PF = .35) 0.7A @ 75 VAC inductive (PF = .35) SILENTNI This document is not intended to be used for installation purposes.We try to keep KNIGHT our product information up-to-date and accurate.We cannot cover all specific ouonnmi�� applications or anticipate all requirements.All specifications are subject to change LIE without notice. For more information,contact Silent Knight 12 Clintonville Road, ini by Honeywell Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com Asembled in USA INTELLIKNIGHT ACCESSORY SILENT SK-Minimon . 4 ` KNIGHT by Honeywell Intelligent Mini Monitor Module I The SK-Minimon addressable mini monitor modules for use with Silent Knight IntelliKnight fire alarm control C_ panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description The SK-Minimon is an addressable ''—z---7:4=1=1-1=-7,1..,w,-s ' '" $,,, J t ;;;r y# ,, k d+ ,• monitor modules for use with the IntelliKnight fire alarm control panels (FACPs). The SK-Minimon acts as an interface to contact devices, such as waterflow switches and pull stations. *° The SK-Minimon supports Class B ` supervised wiring to the load -a device. Conventional 4-wire smoke detectors can be monitored for ` ^ alarm and trouble conditions - 4 The SK-Minimon can be mounted in a single gang junction box "" directly behind the monitored device. Its small size and light SK-Minimon weight allow it to be installed without rigid mounting Specifications Compatibility requirements. The SK-Minimon is compatible with Electrical Features Standby Current: 400 uA max @ the following IntelliKnight Systems: • Single contact monitor 24 VDC with comm. 5820XL • SK-Minimon support for Class B Voltage Range: 15 - 32 VDC 5820XL-EVS (Style B) contact monitor wiring End of Line Resistance: 47 k Ohms 5808 5700 • Small and lightweight size allows physical 5600 (Rev 2.0 or higher) for flexible mounting options Dimensions: • Rotary address switches for fast 2,75"W x 1.3" H x 0.5" D SK- FT 1 installation Weight: 1.2 oz (37 g) • UL listed Environmentalmpe Operating Listings Terature: Humidity: UL 32°F— 120°F (0°C—49°C) CSFM FM 10%—93% non-condensing . INTELLIKNIGHT ACCESSORY SK-Minimon Intelligent Monitor Module Engineering Specifications i The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. IN -i . _ 1 SLC + OUT FY 0 ADDRESS 15 ,,i 14 . 2 t 2 13 3 12 .4 l Compatible FACP 11 1 5 5 9 8 7 6 LOOP 9 8 7 6 TENS ONES n n (-1--(11-- - L(iL- + + - w 37 c - C a o -o o o L4______4-1 I. Other Devices Wiring the SK-Minimon SILENTNI it This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover KNIGHT all specific applications or anticipate all requirements.All specifications are FORM#350133 Rev E subject to change without notice.For more information,contact Silent ©2013 Honeywell International Inc by Honeywell Knight 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, Fax: (203)484-7118.For Technical Support, Please Call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY litSILENT SK-Monitor-2 KNIGHT by Honeywell Intelligent Dual Monitor Module The SK-Monitor-2 module is capable of monitoring two separate Class B. circuits simultaneously, making it ideal for waterflow tamper switch and flow switch monitoring. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Monitor-2 is an addressable monitor module with two initiating circuits for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Monitor-2 acts as an interface to contact devices such asa ' waterflow switches and pull stations. � ���� u The SK-Monitor-2 supports Class B supervised wiring to the load device. Conventional 4-wire \\\ \k\? \ ®am u smoke detectors can be monitored for alarm �� ` v`�° and trouble conditions. SK-Monitor-2 Installation Features SK-Monitor-2 mounts directly into a 4" • Monitor two circuits, with unique addresses, square electrical box. The box must have simultaneously a minimum depth of 2-1/8". A surface • Support for Class B wiring mount electrical box (System Sensor® • Fully supervised part number SMB500) is available from • Panel controlled status LED that flashes green Silent Knight. in normal state and is solid red in alarm Compatibility • Attractive ivory cover plate The SK-Monitor-2 is compatible with the • Rotary address switches for fast installation following IntelliKnight FACP's: • SEMS screws for easy wiring 5700 • UL Listed 5808 5820XL 5820XL-EVS i f INTELLIKNIGHT ACCESSORY Model SK-Monitor-2 Intelligent Dual Monitor Module _ To Next Device 4 i n n l . • c:1 cl t Lili T IC i � 7 is .0 1�JL 14) (0 Oc Compatible FACP %\ U U Two Initiating Device Circuits NFPA Style B Power Limited 230 pA Max @ 12 VDC Max n n SLC ,- OUT IN 0 °a G /) .... di Al Te II + _ I TS Tr N:n••*•• .1,7811 ��� t III O y' Q 0 c o ---4 • u u Wiring SK-Monitor-2 Modules Specifications End-of-Line Resistance:47K 0 Physical Max IDC wiring resistance: 1,5000 Height: 4.5" H x 4"W x 1.25" D SLC Line Loop Resistance:400 max. Shipping Weight: 6.3 oz(196 g) Environmental Electrical Operating Temperature: 32°F—120°F (0°C—49°C) Operating Voltage: 15—32 VDC Humidity: 10%—93% non-condensing Current Draw(LED on): 6.4 mA max Accessories Operating Current(LED flashing): 750 pA SMB500 4"Square Surface Mount Electrical Box This document is not intended to be used for installation purposes.We try MADE IN AMERICA SILENTN it to keep our product information up-to-date and accurate.We cannot cover KNIGH' all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent FORM#350124 Rev C Knight 12 Clintonville Road, Northford,CT 06472-1610 ©2013 Honeywell International Inc. by Honeywell Phone: (800)328-0103, Fax:(203)484-7118. For Tehnical Support, Please call 800-446-6444. www.silentknight.com * SYSTEM �$ SENSOR® Indoor Selectable- e Output Strobes and Horn Strobes for =_- Ceiling Applications System Sensor L-Series audible visible notification 14 products are rich with features guaranteed to cut s installation times and maximize profits with lower ,V current draw and modern aesthetics. 1` i' Features The System Sensor L-Series offers the most versatile and Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry • with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela The entire L-Series product line of ceiling-mount strobes and horn • Field-selectable candela settings on ceiling units: 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- consuming• Universal mounting plate for ceiling units ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back 1 • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. i: • Compatible with MDL3 sync module ;. Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. -4 Agency Listings SIGNALING LISTED APPROVED I�-1 S5512 FM approved except 7125-1853:0504 S4011 for ALERT models 7135-1553:0503 3057383 a tiyj`,i 4�' 1 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1'/cinch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit°'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) InputTerminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,5,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86800 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-1Z5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts I DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd 3, Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 • 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 I AVDS86800 L-Series Dimensions - 2.47 1.37 = = 0 6.92 �2.50 Ii 06.83 _ /ror r•r \,_ 77.I I -... . II\ / / ' ' ill . ...''')' ' 8 � � 08 I I J Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box 1 1 , ® � �� 011: RR :..:.:::.-:-.,. :,:.-:;:.,-,,,,,,. . ... , .., O J __ . -:- - :::-_- /-::-.-. :,.... „„ ... r Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information l' Model Description Model Description ¢ Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire, Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White Th SYSTEM ©2017 System Sensor �� SENSOR 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to changewlthoutnoticeoortofystemsensorcom Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of the data sheet. AVDS86801•03/17 i k I 1 a , 1 r * SYSTEM t, N $ SENSOR ® 111111111 F11I.I.III F I I Indoor Selectable- Output Horns, - s- i'. rA� ,A allik ' i Strobes, and Horn Strobes for Wall Applications E System Sensor L-Series audible visible notification N fell xv . 1 products are rich with features guaranteed to cut fi . x, f #u K installation times and maximize profits with lower n.0 current draw and modern aesthetics. Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming ground faults. • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all R 3 • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings 1 SIGNALING v' CO ® Of APPROVED I •I LISTED S5512 FM approved except 71251853:0504 $4011 for ALERT models 7135-1853:0503 3057383,3057072 r' L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 11/2-inch back box,4-inch 1 octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal ? mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit° Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor • L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act i requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. lSynchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more 'l synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. F Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1'2 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1. 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. f 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. 4 l f ;C i .. k UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) I • 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 I Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts i DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd a. Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 '', Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 it 3.1K Temporal High 93 156 53 73 119 140 164 190 242 tt 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 r' 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 is 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 4 3.1K Non-Temporal Low 77 102 156 177 199 234 291 € I r Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) > 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 s 9* Coded High 85 90 90 ( 10* 3.1 KHz Coded High 84 89 89 *Settings 9 and 10 are not available on the 2-wire horn strobes. it s; L-Series Dimensions _ = 1.91 3.46 a --3.46 1.25 t = = 125 i • tttrtr °O 0 °o°o°oo0oo°o° III 1.144t4 aa0°0aa,a,a�a 0000000000000 .a.0.a.a.0.0. 0000000000000 5.27 i 5.27 000000, !JII_,i 11 � `e aaaaaaa a. 't, Compact Strobe/Horn Strobe Compact Horn 4.70 (,-- _ = 1.91 4.70 1.25 �`'�'� _= 1.25 t 11V . ', .,..,„_,., ,,,,„„„„„ 5.67 "�.. .67 :: ..... ,I 'aa�a'aa4 ,aaaaataaaa q:!:!:!:!' /). Strobe/Horn Strobe Horn L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns P2RL 2-Wire,Horn Strobe,Red HRL Horn,Red P2WL 2-Wire,Horn Strobe,White HWL Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red P2GWL 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red ' P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red Wall Strobes SBBWL Wall Surface Mount Back Box,White SRL Strobe,Red SBBGRL Compact Wall Surface Mount Back Box,Red SWL Strobe,White SBBGWL Compact Wall Surface Mount Back Box,White t. SGRL Compact Strobe,Red 1 SGWL Compact Strobe,White SRL-P Strobe,Red,Plain • SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT • Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover All-ALERT models have"ALERT"marking on cover TSYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2017 System Sensor, Phone:8 www.systemsensor.com •Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com SENSOR y or current product information,including he latest version of this data sheet. w-SEN OR2•Fax: 30 AVDS36503.03/17 s i jrr k �1 T . , SYSTEM �$ SENSOR® Selectable-Output - .- Low Frequency Sounder and Low Frequency Sounder 1 i: . , 1 p a ,, I Strobes for Wall ,.. Applications SPECTwert SpectrAlert®Advance audible visible notification products toramax a ni c are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile • 520 Hz± 10%square wave tone and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry.With white and red plastic housings, • Plug-in design with minimal intrusion into the back box dual listed for wall and ceiling mounting,SpectrAlert Advance can • Tamper-resistant construction meet virtually any application requirement. • Field-selectable candela settings on wall units: f 135, 150, 177,and 185 The wall-mount low frequency sounder,and low frequency sounder strobes were designed to address the NFPA 72 sleeping space • Rotary switch for low frequency sounder tone requirements that require a low frequency notification appliance that 1 • Universal mounting plate for wall units operates within frequency range of 520 Hz± 10%and is of a square wave tone.Like the entire SpectrAlert Advance product line they • Mounting plate shorting spring checks wiring continuity before device installation include a variety of features that increase their application versatility while simplifying installation.All devices feature plug-in designs • Electrically compatible with legacy SpectrAlert devices with minimal intrusion into the back box,making installations fast • Compatible with MDL3 sync module and foolproof while virtually eliminating costly and time-consuming • Listed for ceiling or wall mounting ground faults. To further simplify installation and protect devices from construction damage,SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring,so installers can test wiring a continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, Agency Listings automatic selection of 12-or 24-volt operation,and a rotary switch for 520 Hz low frequency sounder tones. i SIGNALING ® ® MEA LISTED APPROVED approved We S4011(sounder) 3047563 MEA452-05-E 7135-1653:0223 S5512(strobes) 7125-1653:0224 I.. SpectrAlert Advance Specifications • Architect/Engineer Specifications 1 General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch i. octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuif"'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- ; wave rectified unfiltered power supply.Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150, 177, and 185.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone and have a permanent marking ' on the housing that reads"low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire protective service.The low frequency sounder and the Sync•CircuitTM MDL3 Module accessory,if used,shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts(includes fire alarm panels with built in sync).When used with the Sync•Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts.If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used,then refer to the compatibility listing of the panel to determine maximum devices on a circuit.The low frequency sounder has an option to switch between temporal three pattern,non-temporal(continuous)pattern and coded supply within the frequency range of 520Hz±10%square wave tone.The low frequency sounder shall operate on a coded or non-coded i power supply. Low Frequency Sounder Strobe Combination 6 The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The sounder shall have an option to 1 switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three.Also,while operating the strobes,the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications r°' , Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Frequency Range 520 Hz±10% Strobe Flash Rate 1 flash per second i Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/FWR1 `t Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm Lx 119 mmWx64mmD) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142 mm Lx 119 mmWx33mmD) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions(SBBR,SBBW) (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR,SBBW) (145 mm Lx 120 mm W x 76 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 1 q f 1 UL Current Draw Data UL Max.Low Frequency Sounder Current Draw(mA RMS) • 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal3 High 191 262 138 166 Continuous High 292 384 138 208 Coded High 292 388 153 205 UL Max.Current Draw(mA RMS),2-Wire Low Frequency Sounder Strobe,High Candela Range 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 3 277 292 325 344 Temporal 3 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Low Frequency Sounder Tones and Sound Output Data Low Frequency Sounder and Low Frequency Sounder Strobe Output(dBA) 1 • 8-17.5 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR DC FWR DC FWR 1 Temporal 3 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3t Coded 80 80 80 80 80 80 90 90 t Sounder ratings provided are for continuous voltage as provided by the NAC o I a t F SpectrAlert Advance Dimensions • 14 4.7 in. . 2.5 in. ► N 4.7 in. �1.3 in II n n ' _,-----m---, • _ „,. • ,r 1 ,., ill VI Er V 6.4 In. 5.6 in. a a '(,, ' I I I tw 141131' ' ill 17 110.14361 I -.........31411114/.._,- , _w O 4!�- , w Wall-mount low frequency sounder strobes Wall-mount low frequency sounder :I ,, 4. SpectrAlert Advance Ordering Information t, Model Description is Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe,High cd,Red 1 P2WH-LF 2-Wire Low Frequency Sounder Strobe,High cd,White Low Frequency Sounders I HR-LF Low Frequency Sounder,Red HW-LF Low Frequency Sounder,White Accessories SBBR Surface Mount Back Box,Wall,Red SBBW Surface Mount Back Box,Wall,White TR-HS Trim Ring,Wall,Red Notes: "High cd”refers'to strobes that include 135,150,177,and 185 candela settings. *� . /S>'EM 3825 Ohio Avenue•St.Charles, IL 60174 ©2015 System Sensor. Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com -V SENSOR www.systemsensor.com for current product information,including the latestversion of his data sheet. AVD516404.1/15 f i *� SYSTEM Y `.� SENSOR' Outdoor Selectable- Output Horns, • Strobes, and Horn Strobes for Wall Applications SPECTRANert SpectrAlert®Advance outdoor audible visible products A N v A IIIV c E are rich with features that cut installation times and maximize profits. n 11. Features SpectrAlert Advance offers the broadest line of outdoor horns, 1' • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic {t housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application -i. • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. i • Field selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable '! installers to easily adapt devices to meet requirements. • Horn rated at 88+dBA at 16 volts • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before devices are installed,so installers can verify proper wiring without f • Plug-in design with minimal intrusion into the back box ii mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. i Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater [ T corrosion.Knock-outs located on the back eliminate the need to drill j.. SIGNALING holes for screw-in mounting.Plastic and metal weatherproof back I I boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch MEA 7300-1653:187(outdoor strobes) r 54011(chimes, USTED stro"figs,horns) APPROVED approved 7125-1653 188(horn strme obe, knock-outs at the back.A screw-in NPT plug with an 0-ring gasket hornS3593(outdoor and alerl strobes) 3023572 MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. iiq SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'°Module accessory,shall be powered from a non-coded notification iI appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The I horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. 1' i i M, 11 AVDS01201 1 a UL Current Draw Data s UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) i;j • 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 1 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 s 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) .. 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 1 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 135 135 Temporal 75 75 81 81 88 84 96 92 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. Avoso12o1 SpectrAlert Advance Diagrams • li---4.7" 2.5''=+ i ,,;'" '%A:V",';',4 \ . 1 IN Mr MI r ...__ , .,=........6 1 III j------..r, o- ,. J 5.6. II)) r.� �� iii �Ilik--. �t o a �I. I■ v\� Wall-Mount Horn Strobes - Wall Plastic Weatherproof Back Box `ice f'�, I ' o",?®..04 I ��1i tioIII . 1111 1 ,��;iii ,1 tO r 11111 ' Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) 1. P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) _) Wall Strobes ISRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) ii SRHK*t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. *�1 SYSTEM ©2012 System Sensor, -' SE/VSORr 3825:8 0Avenue•S•.Charles,3 7-649 Product specifications subject to change without notice. rsttrt systemsensor.com Phone:800-SENSORS•Fax:630 377-6495 for current product information, the latest crson of this data sheet. AVDS01201•3/12 F Lt i e °t