Loading...
16600 SW 72ND AVE • BUILDING PERMIT APPLICATION CITY of TIGARD DATE , 19 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED BUILDER PHONF OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS. OWNER PHONF LOT NO. OWNER JOB ADDRESS HOME ADDRESS ARCHITECT ENGINEER BUILDER ADDRESS DESIGNER STRUCTURE ❑NEW 0 REMODEL ❑ADDITION 0 REPAIR ❑RENEWAL OFIRE DAMAGE ❑DEMOLITION ❑ RESIDENCE ❑COMM ❑EDUCATIONAL ❑GOV'T ❑RELIGIOUS❑PATIO ❑CAR PORT ❑GARAGE ❑STORAGE❑SLAB OFENCE l LBOND ❑MOVING ❑CONDITIONAL USE ❑DESIGN REVIEW ❑COUNCIL APPROVED ❑SIGNS OCCUPANCY LAND USE ZONE BLDG.TYPE FIRE ZONE_ PLAN CHECK BY HEAT 4s .# ;-!t "1,1:7 —1— "P "..,.o or.t1,.ntl P°t rt.iti '` l ane v7Jm dtt cert tr OCC. LOAD FLOOR LOAD HEIGHT NO.STORIES AREA NO.BEDROOMS VALUE BUILDING DEPARTMENT SET BACKS FRONT REAR LEFT SIDE RIGHT SIDE Permit THIS PERMIT IS ISSUED SUBJECT TO THE REGULATIONS CONTAINED IN THE BUILDING CODE, ZONING Plan Check REGULATIONS AND ALL APPLICABLE CODES AND ORDINANCES, AND IT IS HEREBY AGREED THAT THE WORK WILL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND IN COMPLIANCE WITH Sub-total ALL APPLICABLE CODES AND ORDINANCES. THE ISSUANCE OF THIS PERMIT DOES NOT WAIVE . RESTRICTIVE COVENANTS. CONTRACTOR AND SUB CONTRACTORS TO HAVE CURRENT CITY BUSINESS State Tax LICENSE. SEPARATE PERMITS REQUIRED FOR SEWER, PLUMBING AND HEATING. Total By AP ICANT OR AGENT Approved • Receipt No. . ADDRESS PHONE DATE INSP. TYPE INSPECTION REMARKS ; PLUMBING DATE X,9-7-7‘ l_'-csvt-e--ce_-� � Contractor //—21- 4 ' le—e-os . Permit No. Rough-in Fixture Final HEATING Contractor Permit No. Gas or Oil Rough-in - Final SEWER Final DRIVEWAY Final Storm Drainage (Rain Drain) Final Sidewalk Curb &Street Final Approach BLDG DEPT. FINAL TEMPORARY CERTIFICATE OCCUPANCY Final CERTIFICATE OCCUPANCY • • Landscaping • Zoning Final • - 1 v BUILDING P" 'MIT APPLICATION TIGARD DATE ,19 • THEUNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED BUILDER PHONE OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS. OWNER PHONE LOT NO. OWNER JOB ADDRESS l6'. JA SW 72nd Bldg # 10 ARCHITECT P.O. BOX 841 ENGINEER BUILDER 4,0 1 L 1 ADDRESS Tualatin, 97062 DESIGNER STRUCTURE ❑ NEW ❑,REMODEL ❑ ADDITION ❑ REPAIR ❑ RENEWAL ❑ FIRE DAMAGE ❑ DEMOLITION Q-;RESIDENCE ❑ COMM ❑ EDUCATIONAL ❑ GOV'T ❑ REIJGIOUSLIPATIOLICARPORT ❑ GARAGE ❑ STORAGE ❑ SLAB❑ FENCE OCCUPANCY .u— LAND USE ZONE L BLDG.TYPE "' FIRE ZONE PLAN CHECK BY HEAT Construct -Htorior tenant modification -;ar approved nIa.m lac. red SEWER PERMIT# OCC.LOAD FLOOR LOAD HEIGHT ""' NO.STORIES AREA NO.BEDROOMS VALUE BUILDING DEPARTMENT _ SET BACKS FRONT REAR LEFT SIDE RIGHT SIDE Permit THIS PERMIT IS ISSUED SUBJECT TO THE REGULATIONS CONTAINED IN THE BUILDING CODE, ZONING REGULATIONS AND ALL APPLICABLE CODES AND ORDINANCES, AND IT IS HEREBY AGREED THAT THE Plan Check WORK WILL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND IN COMPLIANCE WITH ALL APPLICABLE CODES AND ORDINANCES. THE ISSUANCE OF THIS PERMIT DOES NOT WAIVE Sub-total RESTRICTIVE COVENANTS. CONTRACTOR AND SUB CONTRACTORS TO HAVE CURRENT CITY BUSINESS LICENSE.SEPARATE PERMITS REQUIRED FOR SEWER,PLUMBING AND HEATING. State Tax SDC— Total PDC# APPLICANT OR AGENT By Receipt No. Approved ADDRESS PHONE ►TE INSP. TYPE INSPLCT`ION REMARK:. PLUMBING DATE dpi _ _-- "` a S ;v /� .11._,__, I Lj Contractor • ,/ �e-eua k3-4 4 A. ,.(/U w ©/ Permit No. s I �l/? __ I y/G/i— 15 ,b0 W:13 :-.:W .+// ��e ' I Rough-in __ _C,72-1+ gleZ -10;/ i�Y . i L. • ./^y 04• Fixture i�i1 /�[`✓ " --- --- I Final �/9. s HEATING I( Contractor /L.A .. .L • // i Permit No. ' 5-1,6 "'7/� "/ -1S Gas or Oil Rough-in Final _ _— SEWER Final DRIVEWAY . I Final i { . Storm Drainage (Rain Drain{Final Sidewalk Curb&Street Final _ Approach —BLDG. DEP ,'INAL i TEMPORARY CERTIFICATE OCCUPANCY -- — CERTIFICATE OCCUPANCY Final i Landscaping il Zoning Fina! ..[/,� 1.,�.�fY / r .,,. ',now. ,dip,/a1Vi/-�. �✓ - \ �,.,.t...H y t.?:-- �'::: ' ri .•-'?ns w*Filk ' " %w 'ss.N �., ;,z,:' ;' ..r'rr y',fi : ?'."i "r` ...' -1c' � a2l f *; .ai+ ,a.:r.' , ve:-4'r- V? rtVe sly' ,"'" t0('' ,•, 1' ''.0,Y.4,1 'w r fire �, 1 A 'C ty,D eR' :a. r, 146t..-... ..14, 1 y a 44 JI i :: 4. ,::''‘')/'' , ., -4-.5,..t.". . .4 "'�`�yy y. .T '.:��.y .;,ti G'�- a• :���,:.S4y.•FriMsto :Vi��/� �. ,•Ki z.. tb * S• ,..-�i��4.E`��r rl,r'i4 y9'" :•^`� ,p„���° � r,...}l._ E. 4 f -'.914 ' S fiPOLIIMIN� , $ 'MTW r''.. `` �.+k 4 1 y('i `.+ �...:1� 1. > f .i' ....Y 'uA. t;. t wu w., ti -Y • t.,w,y, -,:_z: + tt jl''��1 .A' k t lrr..'ikt -xw 4 1'y w.. f .Y 1 .c' 0..2/� `, tit'-a. ' Y. /11 :.� i f ''w. f "f ,>-:'' .. „ ;,s", C:dq ;'7 " ;, ' �'.?r :. ,�'- :::�-t �j ,= • ,rte ' ''w e''`` a ^75.. , ' b/�y 'T, - f"'� l:� p1, \% �� . q. •.?-., a•.v..,9,1-.5,11=••,r,a. •r n F �6...... - ,7.e. ...... 4 5 s.�� .-I.) L j,J.;' �`, ¢.v.�9a7rsoaamrosvrwc va nv.a�m,rq¢.ar:s.�: ...,. �'_ c� FIA aanro.7iwn --1 s �. 7rN7 :: � ,." � .. E I sill ..„ , CIRTI�IOF UPA Cy , { ' in CITY OF TIGARD . 4:� * ' OREGON � . Owner: Optical Data Permit No. 5203 y, ),),. -O• ,0( Address: P.O. Box 841 ,'� i Building Address: 16600 SW 72nd Bldg. #10 ,e• C. , , `,1. Occupancy: B-2 Land Use Zone: I—L Bldg. Type 5N ,"'i - I r ,.'" '' 1 Comments: Construct interior tenant modification. E I`r f . ' „'" Certificate is hereby given this 15th day of July , 1985 .. , '- r ' A ^,• that said building may be occupied and that it complies with all , •i „ 0 0 requirements oi.the Building Code for the City of Tigard, as approved _ '- ,• , ; '/, " - by the Tigard City Council. r 9 e?t \Y : G�j'1 -edi ,,-,...1- ,i,_, ,)2 ,, b, , _ J ti,i1-)-ki,!)-) Ne-7 / ,„. ,J -,,,..---6 ::: P.:\'‘'.;,111,1,:q‘k 3 way V P Q Fire Dept. • ng Inspector 1 ; v tel/ �// �/ � Ilf,.;i $ � 4,/ Building Official _ .� a ''� r s� Post Certificate in Conspicuous Place • e ' 'L.�' •" .trF ;:kr'' '•..:�,. -L " .'+:� _._.d3f'9 G: ,;,k 5 .. J •r4 • •,-". '. —y— '' ._ <. ;. ity 3t- / .,, —,,.,...L.....„--,,,.., . epam.,.... mbe. nrneeme:re..eeeneenA.... a�`,1.................................. J -_ mm. x ..s1, 9Y -?.. rL ../....:.,..L.,,•Y•102 •WNbNbbn'4Gb4•bbbn a�" p y $) r ,:4 e�:t r � '' .. 41.P.t' 4",.. � "J. .y a�s' b9,C �' GV} w -•t• fFt ;�.‘t" ',J t ,Yy' (9asV ' t : pi: F#k� Ir f :F. aai- iIx" 6 �� Hti>"' ,�v tr�. t4Yf .7 �=. a dlt i®_ �,a,A �.. , f ih;�` . 1:.tr tr. . ;�.tr4 - ' J ,- r .^.. .-11C, ` T9 ;� Y ' ,7-' .134:1-- ,. tr ''*!E•a ' Y3 > ~, ,w.,4Toge, tIl �e4 1 ,„ '"A yP, ' x�� At,�r ` TATr +�N hw,'+ 4.-,, g � / .`,r eh, k �°" r,' Rvt . r�Adi" °y *-d s •,'.. .', @�`# : `9 °� . , 9'.. ..t...,..4„.: , ham.,,e.,,,„........,,, rtR " � "k. ,,y. �ws ,„ " . , o,, r III +rx+ Mere_� �*� �� U GOES 57 LITHO IN U.5.H. Oh. INSPECTION NOTICE City of Tigard Building Department - r/ 12420 S.W. Main St. ��r1�� � �, Tigard,Oregon 97223 Phone: 639-4171 Type of Inspection P M -14 -1Time —A.M. -- Date Requested ���r a Permit # %.1. __,. Address Lot # Owner k e- it_,,, Builder The following Building Code deficiencies are required to be corrected: J0fa''1 `. 1 L L C'' l 41 ./ I. A LI A / ' , r t,l t Approved Presented to Disapproved Inspector Date CALL FOR REINSPECTION [/YES 0 NO w 0 BUILDING PERMIT APPLICATION TIGARD DATE 19 ' THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED BUILDER PHONE-:'`'..-f_as'ti OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS. OWNER PHONE, LOT NO. _ JOB ADDRESS ,' OWNER; - , _ `; : ;_.. : _ � _ / ARCHITECT J,.?lJ, 43,0, ,-;.„--,../' ENGINEER BUILDER i, r- ADDRESS '' , ,� 14, l'', , ,DESIGNER STRUCTURE 0 NEW 'REMODEL 0 ADDITION 0 REPAIR 0 RENEWAL 0 FIRE DAMAGE 0 DEMOLITI ❑ RESIDENCE? .COMM 0 EDUCATIONAL ❑ GOV'T 0 RELIGIOUS 0 PATIO 0 CAR PORT 0 GARAGE 0 STORAGE 0 SLAB❑ FEN( OCCUPANCY LAND USE ZONE BLDG.TYPE PLAN CHECK BY ° HEAT P �, C 1_ SEWER PERMIT k OCC.LOAD FLOOR LOAD '' HEIGHT NO.STORIES AREAS%ti- --"' .- NO.BEDROOMS — VALUE . '., BUILDING DEPARTMENT SET BACKS FRONT REAR LEFT SIDE RIGHT SIDE MEM ' THIS PERMIT IS ISSUED SUBJECT TO THE REGULATIONS CONTAINED IN THE BUILDING CODE,ZONE' REGULATIONS AND ALL APPLICABLE CODES AND ORDINANCES, AND ITI IS HEREBY AGREED THAT Ti '"`I Plan Check WORK WILL BE GONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND IN COMPLIAN, 2 C7 WITH ALL APPLICABLE CODES AND ORDINANCES. THE ISSUANCE OF THIS PERMIT DOES NOT WA!' Al;S�,S�px t ,% ' RESTRICTIVE COVENANTS.CONTRACTOR AND SUB CONTRACTORS TO HAVE CURRENT CITY BUSINE. UCENSE SEPARATE PERMITS REQUIRED FOR SEWER,PLUMBING AND HEATING. State Tax • SDC— Total 1 POC# APPLJCANT OR AGENT By Receipt No. ADDRESS PHONE Approved n SSDC _ --- $ 2 — 7"4-1 SDC — 2.02Z -' PDC -A . I SEWER CONNECTION 5 SEWER INSPECTION $ SEWER SURCHARGE 5 , I - Cnmmorlts 1.-c- '_1-) <• '� r ,1 c -P so CITY OF TIGARD No. 2291 hole ;IA 12755 S.W.ASH s ,4; 2:1 PP.O.BOX 23397 Date 2-7' h S TIGARD,OR 97223 tr- GIyICL: Name � Address ( 4 i r� Lot Block/Map Subdivision/Address 2 Permit #'s Bldg. Plumb Cash Check Sewer Other Other Rec. By , Acct. No. Description Amount 10-432 Building Permit Fees 10-431-600 Plumbing Permit Fees 10-431-601 Mechanical Permit Fees 10-230-501 State Bldg. Tax 10-433 Plans Check Fee 125-. //3- 10-435 2.5 . L/3- 10-435 Other Licenses & Permits 30-443 Sewer Connection 30-444 Sewer Inspection 24-448 Street Syst. Dev. Charge 25-449-610 Parks I Syst. Dev. Charge 25-449-620 Parks II Syst. Dev. Charge 31-450 Storm Drainage Syst. Dev. Charge 10-430 Business Tax 10-434 Alarm Permit 10-227 Bail 10-455- Fines - Traffic/MisdlParking 10-230- CPTA Traffic/Misd/Vic. Asst. 10-456 Indigent Defense 30-446-401 Sewer Service/USA _ 30-446-402 Sewer Service/City 31-447 Storm Drainage 40-475 Bancroft Prin. Pymt. • 40-471 Bancroft Int. Pymt. 10-451 Other Charges for Services TOTAL M► _ 202, i f `* DEPT. 1 ®s I ROBERT G. EARLE INCORPORATED P.O.BOX 841 TUALATIN,OREGON 97062 [503]692-3232 February 12, 1985 Mr. Cal Ditch Optical Data Inc. P.O. Box 23639 Portland, Oregon 97223 Re: Hallway Construction Dear Cal: Yesterday I discussed hallway construction with Gene Birchill of the Tualatin Fire District. Mr. Birchill conveyed the following information: • The hallway as shown on the drawings would not require one hour construction. • The occupant load for the hallway does not require one hour construction. • Should you add future rooms to the hallway, or extend the hallway, the hallway would require one hour rated construc- tion and 20 minute labeled doors and jambs. NOTE: • The existing Darkroom and the existing Chemical Lab are not constructed to meet one hour fire ratings. • To meet one hour rating the existing drywall on the corridor side of the darkroom and the lab would have to be covered or replaced with 5/8" fire rated gypsum. • The darkroom doors and frames would require replacement with U.L. rated and labeled doors and frames. Please advise me of your decision. Sincerely yours, Robert G. Earle RGE: je *OREGON* 1111 11 TIO RURL HR€ PROTCTLR OSTUCT fale TOfl �fl `y P.O. BOX 127 • TUALATIN. OREGON 97062 • PHONE 682-2601 4411 ,`pc-0� OPTICAL DATA. l? C. June 19, 1984 # 905 Attn: Tom Wiitala 1220 SW Morrison Portland, Or 97205 9182- 1 354B-048-001 Dear Pacific Realty Trust, 2) This is a Fire and Life Safety Plan Review and is based on the 1982 edition of the State of Oregon Structural Specialty Code and Fire and Life Safety Code (UBC ) and the 1982 edition af, ,the State of Oregon Mechanical Specialty Code and Mitha�t ical Fire and Life Safety Code (UMC ) and local ordinances. 1014) RECOMMENDATION: When future clean rooms are added and the occupant load exceeds thirty '(30) a one-hour corridor shall be required between clean rooms and dark room/chemical laboratory. The one-hour corrzd r shall extend until egress is provided from the, building aWd shall have openings protected by a tight- fitting smoke and draft control assembly having a fire pro- tection rating`,o=f not less than 20-minutes. UBC 3305(g ) 2134 -Nth ;less tha' t're approved fire extinguisher rating 4 trot less than 2-A: 10-B: C steal 1 be pro 'ided for akei eke1, 500 sq..' ft. of floor area or fraction tbereof. The travel distance to an extinguish from any portion of the building shall not exceed 75 ft. (UFC Standard No. 10-1. ) 10) Approval of; subm tted plans is not an approval of omfsszOn''s or oversights by this' office or of non- complian`ce with any applicable regulations of local government. If you desire a conference regarding this plan review or if you have questions, please contact Gene Birchill at (503) 682-2601. Dallas Allee Fire Prevention Bureau TFFMZ260 OCCUPANCY FILE LIST JUN 20, 1984 14: 25: 17 TUALATIN R. F. P. D. PAGE 2 ,' <KEY INFORMATION> Assignment Code E222C _. <CONSTRUCTION INFORMATION> :" <FIREPROTECTION INFORMATION> {, FMZ-Occupancy Number 1. Floor Construction : 2,CONCRETE 1. Hazard Class 901 : 792 354B-048-001 2. Floor Covering T_: 2,CONCRETE 2. UBC 0cc Class 1 _�- : B-2 3. Roof Construction "'' • 3,WOOD LAM 3 2 Bus-Occ Name & Address 4. Roof Covering : 3,CLASS C 4. . 3 . 5. Flue -Typ METAL 3.:._._ 4 • .. . OPTICAL DATA, INC. 6. Heating System Type GAS 6. Heater Room Enclosed : N 16600 SW 72 AV T? 7 Interior Finish Type. 8.NONCOMBUST 7. Number of Stairs 3 <BASIC INFORMATION: 8 Exterior Finish Type: 1,MASONRY 8. Stairway Enclosed N u'7` 9. Structure Columns : STEEL 9. Number of Vert Shafts . 0 ?Occupancy Phone 503-620-1920 10. Construction Type : III-N 10. Exits 11 t. . . tlanager`s Name & Phone 11. Total square feet : 141908 11. __-- Attic_ Stops 0 12. Ground Area Sq Ft. 137908 12. Alarm Shutoff Loc . I-E 2. James Serres 13. Basement sq ft 0 13, Power Shutoff Loc : I-S ; ( 3. 503-635-5515 14. Building_Height : 30 14. Water Shutoff Loc - : 0-W ...,,,VAN;...,-,- ;t"1 15. Number of Stories 2 15. Nat Gas Shutoff tote,,' 0-S Business Mailing Address 16. Building Value 1959253 16. Fire Dept Conn Loc j 0-SW - - W 17. Contents Value „ : 4500000 _ 17. Sprinkler Control Lot : I-S 4. 18. Other Value 0 18 Type of Spr System yp p y 1, WET PIPE 5. 16600 SW 72 19. Ins - Building 1959253 19 Number of Heads 1324 6. Tigard, Or 97223 20. - Contents : 7000000 20. _Sprinkler Supervised". Y 21. Occupancy Square Ft 46240 21. Hazard Classif EXTRA Owner's Name, 'Phone, & Address 22. Ceiling Type NONE 22. Anti-Freeze System N 23. Wall Framing s, -: 3,CONCRETE 23. Area Covered by__Spr 100 7. Pacific Realty Trust 24. Stand Pipe Size 1. 5 8. 503-224-6540 25. Int/Ext Stand Pipe : INTER t 9. #905 Attn: Tom Wiitala 26. Water Available : HYDRANT 10. 1220 SW Morrison 27. Attic Access Loc : `NONE 11 Portland, Or 47205 -- � ,. <SECURITY It ORMATION> 12. Property in Use : YES 13. ISO Class : 3 1. Alarm System Type : AUT , 14. Census Tract 308 2. Alarm Number 15. Code Edition Used : 1970 3. Alarm Comment Code : BURGLAR 16. Date Built : 01-01-74 4. Guard Security Service : NONE 17. Date Remodeled 01-09-82 5. phone : NON-E - 18. Insp. Type/Month : INF /09 6. Watchman on Duty : N 19. Property Type : WOOD PRODUCTS 7. phone : NON-E E 20. Special Haz Type : PAINT ROOM 8. Guard Dogs N 21, Special Hazard Loc: I-SW 9. Guard Dog Owner's Name : NONE 22. Misc. Number 1 0 10. phone : NON-E - �_ =- /' 14.0 if BU I ='G PERMIT APPLICATION TIGARD DATE ,19 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED BUILDER PHONE OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS. OWNER PHONE LOT NO. OWNER JOB ADDRESS ARCHITECT ENGINEER BUILDER - ADDRESS DESIGNER— --STRUCTURE ❑ NEW ❑ REMODEL ❑ ADDITION ❑ REPAIR ❑ RENEWAL ❑ FIRE DAMAGE ❑ DEMOLITION ❑ RESIDENCE ❑ COMM ❑ EDUCATIONAL ❑ GOV'T ❑ RELIGIOUS ❑ PATIO ❑ CAR PORT ❑ GARAGE ❑ STORAGE ❑ SLAB❑ FENCE OCCUPANCY LAND USE ZONE BLDG.TYPE __FIRE ZONE _PLAN CHECK BY _ HEAT ___ SEWER PERMIT# OCC.LOAD FLOOR LOAD HEIGHT NO.STORIES AREA NO.BEDROOMS VALUE BUILDING DEPARTMENT SET BACKS FRONT REAR LEFT SIDE RIGHT SIDE Permit THIS PERMIT IS ISSUED SUBJECT TO THE REGULATIONS CONTAINED IN THE BUILDING CODE, ZONING REGULATIONS AND ALL APPLICABLE CODES AND ORDINANCES, AND IT IS HEREBY AGREED THAT THE Plan Check WORK WILL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND IN COMPLIANCE WITH ALL APPLICABLE CODES AND ORDINANCES. THE ISSUANCE OF THIS PERMIT DOES NOT WAIVE Sub-total RESTRICTIVE COVENANTS. CONTRACTOR AND SUB CONTRACTORS TO HAVE CURRENT CITY BUSINESS LICENSE.SEPARATE PERMITS REQUIRED FOR SEWER,PLUMBING AND HEATING. State Tax SDC— Total PDC# APPLICANT OR AGENT By Receipt No. ,/, "=-,77 ? PHONE Approved ADDRESS DATE INSP. YPE INSPECTION REMARKS PLUMBING DATE i�i�_�` Contractor _a _ yr _ .— � 0�5 ' �5� ��, ,�� �- Permit No. 31,20)...) 6 vt9 6� zQ` / + / I'LL --� Q� . Rough-in 7Ar r kiww� �/ I/ Fixture �— Final . — HEATING Contractor Permit No. Gas or Oil - Rough-in Final SEWER Final DRIVEWA t` — Final Storm Drainage (Rain Drain)Final -- �_— Sidewalk Curb&Street Final APProaeh BLDG. DEPT. FINAL 1 TEMPORARY CERTIFICATE OCCUPANCY 4CERTIFICATE OCCUPANCY Final Landscaping Zoning Final rx7SS' 5.Wt ,4514 -Ave SaVg� 1— r A rT. X L n X311 BUILDING PERMIT APPLICATION TIGARD DATE ( 2 142_ ,19 8'4 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED BUILDER PHONE - OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS. OWNER PHONE Z2•4 -2's5S' �c��`c= -',•s"c U 7,..„--- w LOT NO. DRESS 0 . S �: - al,'G. 0 - ,' 1 0 , OWNER p_ L JOB ADk _ ...1. IARCHITECT /^ r...ci `/^ ENGINEER 'f BUILDER Vit. G . SI.('ADDRESS DESIGNER M�1(,, �244Sr(j iC, STRUCTURE gr NEW .v9 nEMODEL 0 ADDITION 0 REPAIR 0 RENEWAL 0 FIRE;DAMAGE 0 DEtAOUTION 1 O RESIDENCE,)tOMM 0 EDUCATIONAL 0 Gorr 0 REUGIOUS 0 PATIO 0 CAR PORT 0 GARAGE 0 STORAGE 0 SLAB0 FENCE �.:r -4-.-::---, , OCCUPAriCY ."-4- LAND USE ZONE �' L BLDG.TYPE --3 A'/FIRE ZON -� NT,p PLAN CHECK BY '• '`� HEAT• _i` / - ,_-.7 41, Di- I. r ' - • //t✓e. - P.,4--,q Ap P-R ' l/ 0 P LA A/ l - 1 es,z?4 Pi-5,e,r/7- A'''/-:7a / - • SEWER PERMITW ' OCC.LOAD FLOORLOADc-, ,,'HEIGHT NO.STORIES / AREA/6b L.2 NO.BEDROOMS— VALUE <7 tr' BUILDING DEPARTMENT . SET BACKS FRONT —_.—_.-----__MKT-SIDE Permit S O Sq THIS PERMIT IS ISSUED SUBJECT TO THE REGULATIONS CONTAINED IN THE BUILDING CODE.ZONING h,3REGULATIONS AND ALL APPLICABLE CODES AND ORDINANCES,AND IT IS HEREBY AGREED THAT THE Plan Check WORK WILL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND IN COMPUANCE �.7 3 Zp WITH ALL APPLICABLE CODES AND ORDINANGES.THE ISSUANCE OF THIS PERMIT DOES NOT WAIVE RESTRICTIVE CAVE NANTS.CONTRACTOR AND SUB CONTRACTORS TO HAVE CURRENT CITY BUStNES4 3 2.2 UCENSL SEPARATE PERMITS REQUIRED FOR SEWER.PLUMBING AND HEATING_ te StaTax • Total • /6 8 2 5 FOCI APPUCANT OR AGENT By • Receipt No. Approved ADDRESS PHONE • :s pa 8zJ ..6.-/2-IV SDC - - PDC $ # O S. 7z. SEWER CONNECTION $\'`,. SEWER INSPECTION $ � SEWER SURCHARGE S `' Comments: r • 5!-- . CITY OF TIGARD—12420 S.W.MAIN—TIGARD,OREGON 97223 ` C RECEIPT DATE: '/)- i y AMOUNT: $ 3W.5-6 CSC G14 - G /' 8 /� DOLLARS NAME: �/ c(° L-G E • A- CASH: ADDRESS: /� rogril M.O.: # OF FOR: ACCT. # PERMITS SURCHARGE AMOUNT SEWER BILLINGS 40-364 $ BUSINESS LICENSE 05-331 PLUMBING PERMIT 05-332 $ MECHANICAL PERMIT 05-332 BUILDING PERMIT 05-333 SEWER CONNECTION 40-363 SEWER INSPECTION 40-365 SYSTEM DEV.CHARGE 25-366 PARK DEV.CHARGE #1 30-367 PARK DEV.CHARGE #2 30-368 ZONING ADJUSTMENTS 05-362 ez 3-3c ''�` S .53 Alt) TOTALS $ $ g-V' & RECEIVED BY: PERMIT NUMBERS ASSIGNED: Number Amount Numbor Amount I Number Amount S_ $ $ $ $ $ $ - $ RECEIPT # 18908 .5" 33 AZA/ Ck' ZD 3 2 Z2f"O_ a.i.Ls ♦ h BUILDING PERMIT APPLICATION TIGARD :. DATE _ Y 0 ,'g THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED BUILDER PHONE OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS. OWNER PHONE —_ LOT NO. OWNER Pat. Trust JOB ADDRESS 16400 SW 724.:..- ARCHITECT ENGINEER BUILDER E.L. 0 GreeD ADDRESS 1220 SW iie,rrison DESIGNER STRUCTURE ❑ NEW . REMODEL ❑ ADDITION ❑ REPAIR ❑ RENEWAL ❑ FIRE DAMAGE ❑ DEMOLITION ❑ RESIDENCE E COMM ❑ EDUCATIONAL ❑ GOV'T ❑ RELIGIOUS ❑ PATIO ❑ CARPORT ❑ GARAGE ❑ STORAGE ❑ SLAB FENCE OCCUPANCY 13-2 LAND USE ZONE BLDG.TYPE FIRE ZONE PLAN CHECK BY h---1:1'''' HEAT �/.17/4( /o c 4 d SEWER PERMIT# OCC.LOAD FLOOR LOAD HEIGHT NO.STORIES AREA NO.BEDROOMS VALUE BUILDING DEPARTMENT SET BACKS FRONT REAR LEFT SIDE RIGHT SIDE Permit THIS PERMIT IS ISSUED SUBJECT TO THE REGULATIONS CONTAINED IN THE BUILDING CODE, ZONING REGULATIONS AND ALL APPLICABLE CODES AND ORDINANCES, AND IT IS HEREBY AGREED THAT THE Plan Check 322«:F WORK WILL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND IN COMPLIANCE WITH ALL APPLICABLE CODES AND ORDINANCES. THE ISSUANCE OF THIS PERMIT DOES NOT WAIVE Sub-total RESTRICTIVE COVENANTS. CONTRACTOR AND SUB CONTRACTORS TO HAVE CURRENT CITY BUSINESS LICENSE.SEPARATE PERMITS REQUIRED FOR SEWER,PLUMBING AND HEATING. State Tax SDC— Total PDC# APPLICANT OR AGENT By I# - `702/ Receipt No. Approved ADDRESS PHONE DATE ,I'INNS�P.� �PEINSPECTN REMARKS 11 PLUMBING DATE 8 c� .���II�/: :J �. / 3 —_a�`'ontractor /w e"-<, 1 Permit No. e.pit - /..__2.40. .e. I Rough-in —_ - -7 j?P 0JCC" I Fixture it Final HEATING - IContractor ' Permit No. Gas or Oil Rough-in — I Final SEWER Final DRIVEWAY Final Storm Drainage !Rain Drain)Final _ Sidewalk Curb&Street Final ___ Approach BLDG. DEPT.F U 74i. f TEMPORARY CERTIFICATE OCCUPANCY ICE:-T3"2ICATE OCCUPANCY Final — — (�\ r �, (. `��-! Landscaping I � Zoning Final ^5 'JQr '•�wur1F' 1"i.Gb1I '?'..GX 1.C4'1.�.. J4iw �' ti`i.• !.f ` - y. .4it, 737,Zay , `..yA.'N':W1..,r all... K!'m`4,,,t, 'g "`r,,,,,x- '7`, `7'^t w+''rR.,x'K'"�J'i'"�" ' ,. '�'. ' a5.' 'r s r ,�, - ,,==:" ..40:1:� `�% �i1'�:=ns r;'�'�ti'. Ai��'�� r M•�""+�6 �r•� �`. � -�9"�,m ' �woi ar'y� w'�7+s. 's' ' X. r ". • � -A S .r71d'!• r G•, 0.w r D $., 5.. 1rx n x r .Y.. d4,4,-,p.,,, j ., �..g�!. F 4 ��py, b�'�,�jo a• ,E�, a• n•p•���. �f �'�f1'' ..G'y, '�`� ;.,� 4 .l'."C4 r.BN"' �.� M}-.;.�4 3!� „rte 1:2' -'-'�•�,.,)� ,may.�` ,''i.��i �'=.�y -.��: ...wb' .�.�'. ��'� +`� %f�y{. !':'' .::' --c, 1,-,3 x-;i., ._. *.- t �:. ..;. '+i + ::.�.: 0-40-11. . `-�_ ' iF' _ =,�m„y.^: t`�s ..'.;�_. - .__ a�Q*,.` ., ,�s'..r ` 7 ', tl 1.1 A. C ••k b4 .',•:...',.:. �.A-, - _,. — w.•Y.h...r.3 -q*-- 7 il ' Y�.',V • �.Pl':.i 4�\•+t /o,exE'd�TrY�,i-� 40.--^� ��:� v. _. 5 n At >y F4,„s:.", e. e....„..„., �_ 11�.F.STi'L'G<s7FL•7PL3•L'6G�drhTPA7XarAnamL'IPA+wZl4dCA.d-AFd'..SSgh7J°GFlYL'.G1dXrA'AFIF6d3ffAA'0.'AMa'A•.A'irka4Y1F1FA"4'FiFSEAA.G.aYa'A'LF/F.QAAG.UAAAAAALA.IlQAbA�C_. __ ____ .• f!�c ' v _ _. ___..__ -_— f,14,4,...am• :: 7 ......„,..k . s'iCY Cl g b a AVA:k. 01 CATS OF ocC pt 5w { w, '�, CITY OF TIGARI) , ,o /7 , OREGON , 'y �t - 2' 1 Pact 5361 ' �I� \� i1 Owner: Permit No. ���: l2 Address: n. �� -,,,,,,A-. ..-:: ' Building Address: 16600 SW 72nd, Bldg. 10 : i I *cmx • fir, Occupancy: B2 Land Use Zone: ii Bldg. Type 3N ,, ,. ( Comments: -cam f ,,.ar •• remodel w/o tenant �� . 18th December 85 .� ti Certificate is hereby given this day of , 19 . '. 1 ,. i� that said building may be occupied and that it complies with all 0,,,,...:.•.::'.1C0 ' requirements of the Building Code for the City of Tigard, as approved � �� ,,y*,.-,! by the Tigard City Council. , , .... :1 -' �y`� V. ? Fire Dept. BuildingInspector '` `� '� } --eta' 'y0''1 ? r' • � } 4 Ytt _ ✓• Building Official t� { 4 , Post Certificate in Conspicuous Place tvT J - --- — — - r h - •\ ft• RR9WAaAlAAVALti 4�':+9.4]77EffiS%Y•Y•Y.&4YS•AYSX3•R4A]f.4�Y•L4v0•V4PY�¢v.%�a0.tltlYCtxRtlaVN9[Vd4V7RV•SR4�OA \�• `�.c�s �..c $ _• � . k ,." : J 1516k,40, y,� ., (91 I ., ' v ?,r``�`` t.-_s.` Ir"3� t ,, , `'''t.'-,' ' ' 'l�;i .ds ' ::o'. rti�;+- .:-�'fj.r;w.:V i4'{ i+a'z 'E'a., *,, ,_. 'f''''' t• ? t -1 darn` a. w ��.,r �� t r i�ti..a4 �� fir .,_�t, '�. `fix '� �„ ` '�'` �"i "41Y-Ir' ua r u�, �i'��°�, - '�^^' - .� .;,"�"" ro• „�p�.t'*r•'� �•; tl t,rr,u'}yu,;/: �,:.•wr `" :� � r:• �;;a'� �yb1'. Y{ ' ,s, if.,:::,,,z,„P_:.9 � :' • y'+�"4. wr rr< n.ti: .tri- i.,./t . 4...,,, ,( 6,6„,..A.Y; ^ L. ',,,,,ikM,,,,i' .J�"a't s., ' a.w, s: ,., 3?" ';'+ .n., "°`•-'"eroy. r�+,:r�,i• '�' '..;,:.:,."4-',; trr ---'-0,..,(4-4 ...f1 ,. .k%•.. _ ,,,'^ . ° ,, '.,"" a c.. s"o '.,.sw',t �,„„.."r'•►�•• /\ ''X'............ +si .'r' ria wyt+aow+. a -x......,,,.......„-------__. ®GOESt7 aj)( - 10 S-- S ('P ( • BUILDING PERMIT APPLICATION TIGARD DATE 5'15 . 19 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED BUILDER PHONE 12-1-/902-0 OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS. OWNER PHONE 2•24-2-3 ES 1� LOT NO. �/� t" OWNER tiL✓i JOB ADDRESS I b I9UO 5 int 7Z AP ARCHITECT ,L.Y MZ. ENG// e. 1220 ' 1.4MO S DESIIGNER NEER G'A't �� BUILDER 1-4.t., ( ��� ADDRESS STRUCTURE 0 NEW 'REMODEL 0 ADDITION 0 REPAIR 0 RENEWAL 0 ARE DAMAGE 0 DEMOUTIOI 0RESIDENCE *'COMM 0 EDUCATIONAL 0 GOVT ❑ REUGIOUS 0 PATIO 0 CAR PORT 0 GARAGE ❑ STORAGE 0 SLABO FENC DCCvPANCY Z. LAND USE ZONE T L' BLDG.TYPE 3 FIRE ZONE �' PLAN CHECK BY HEAT. = / �� a'g 1= - • a ,/l ;�ti. zs co•.4.0 (2, ... . • . .. . . • . . . . SEWER PERMIT I -)G2r..i✓CG.fl�zt-: - . DCC.LOAD FLOOR LOADea-i e..®•• HEIGHTG' f"' NO.STORIES f AREA //e NO.BEDROOMS VALUE/ ' • BUILDING DEPARTMENT - SET BACKS FRONT 1714$4-x.-1,-/ — LEFT SIDE RIGHT SIDE Permit THIS PERMIT IS ISSUED SUBJECT TO THE REGULATIONS CONTAINED IN THE BUILDING CODE,ZON!N REGULATIONS AND ALL APPLICABLE CODES AND ORDINANCES,AND IT IS HERE3Y AGREED'MAT TY. PI eck WORK WILL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND IN COIkPUANC WITH ALL APPUCABLE CODES AND ORDINANCES. THE ISSUANCE OF THIS PERMIT DOES NOT WAIV Su tal t ' RESTRICTIVE COVENANTS.CONTRACTOR AND SUB CONTRACTORS TO HAVE CURRENT CITY BUSINES j 0 UCENSE.SEPARATE PERMITS REQUIRED FOR SEWER,PLUMBING AND HEATING. Stile Tax-i• . SOC— Total • /� L�• >�(J / 1 POCK APPUCJINT OR AGENT • By • ( D6410 SW i3Ar4c 3" everofa- DA-4167k . Receipt No. PHONE Approved ADDRESS DC — $ • r DC - S . f EWER CONNECTION S # qco� EWER INSPECTION S ,....._::-.„- 1----7-46.0 � EWER SURCHARGE �.^.1mont.0 i BUILDING RECEIPT ,I(f NAME: �c� L2 DATE: c 9y`(' ,.. t ACCT. # DESCRIPTION AMOUNT 10-432 Building Permit Fees $ /7" S & 10-431-600 Plumbing Permit Fees $ r—' ""- 10-431-601 Mechanical Permit Fees $ 10-230-501 State Building Tax $ l Y P 10-433 Plans Check Fee $ 202, 0, 30-443 Sewer Connection (20%) $ ' 30-202 Sewer Connection (80%) $ 30-444 Sewer Inspection $ 51-448 Street System Dev. Charge (SOC) $ 52-449-610 Parks I System Dev. Charge (PDC) $ 52-449-620 Parks II System Dev. Charge (PDC) $ 31-450 Storm Drainage System Dev. Chrg (SSDC) $ 10-230-505 TRFD (95%) $ / 8Y, c,2_, 10-478 TRFD (5%) $ 5 Y1 / 10-230-506 Washington County Fire #1 (95%) $ > 10-478 Washington County Fire #1 (5%) $ 10-220 Amart/Wedgewood $ TOTAL $ // G 3,-S-76 (bs/1214P) • \!''' � - • -- 1• '` s9` '-• 4,N, .' :„_...0r.'.0.,!`"--,;%.4%."----„,i ".i.....,00 -'-'":"-7......,Vii'' / Y.-''' "'/'-''';'-c-r ,.1,,•;'y/ " { �y;',;. 0 ;. mo i ''s ( : '�- )4 -Q ,g ee ,� 75" -5:.) <7 6 4 6 7 CITY GARD 639.4171 _ BUILDING PERMIT DATE '' ° —19 3tt TAX MAP LOT NO. SUBDIVISION OWNER JOB ADDRESS 6 -0' BUILDER • STATE REG.NO. EXP.DATE BUILDER'S PHONE ARCHITECT PHONE 227-3176 OTHER STRUCTURE ❑ NEW ❑ REMODEL ❑ ADDITION ❑ REPAIR ❑ MOVE ❑ OTHER Li DEMOLITION ❑ RESIDENCE ❑ COMM ❑ EDUCATION ❑ IND ❑ RELIGIOUS ❑ ACCESSORY ❑ GARAGE ❑ OTHER ❑ FENCE OCCUPANCY LAND USE ZONE BLDG.TYPE FIRE ZONE PLAN CHECK BY HEAT SEWER PERMIT# OCC.LOAD FLOOR LOAD HEIGHT NO.STORIES AREA NO.BEDROOMS VALUE BUILDING DEPARTMENT SET BACKS FRONT REAR LEFT SIDE RIGHT SIDE Permit THIS PERMIT IS ISSUED SUBJECT TO THE REGULATIONS CONTAINED IN THE BUILDING CODE, ZONING REGULATIONS AND ALL APPLICABLE CODES AND ORDINANCES, AND IT IS HEREBY AGREED THAT THE Plan Check WORK WILL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND IN COMPLIANCE WITH ALL APPLICABLE CODES AND ORDINANCES. THE ISSUANCE OF THIS PERMIT DOES NOT WAIVE Pl.Ck.Fire RESTRICTIVE COVENANTS. CONTRACTOR AND SUB CONTRACTORS TO HAVE CURRENT CITY BUSINESS TAX PERMITS.SEPARATE PERMITS REQUIRED FOR SEWER,PLUMBING AND HEATING. State Tax SDC— Total APPLICANT OR AGENT PDC# Prepd. Receipt No. ADDRESS PHONE Bal.Due Issued By Approved By DATE INSP. TYPE INSPECTION REMARKS PLUMBING DATE //«/;F" 1 let,' .(� L� 2144,,,t Contract i / � EJ � - L/t Permit No.Vic' / /-may' y' 7—cr 4e9 _ / Rough-in ` Fixture Final 72-A-eZ 7�j� ,f C� /� —.2Z,f),7 - V;#/i HEATING Contractor Permit Gasasoor Oil 3/22/87 L Rough-in Final SEWER Final DRIVEWAY Final Storm Drainage (Rain Drain)Final Sidewalk Curb&Street Final Approach BLDG.DEPT.FINAL TEMPORARY CERTIFICATE OCCUPANCY Final CERTFICATE OCCUPANCY Landscaping Zoning Final boo rkshee - PLAN CHECK NO. •or inspect ions call 639-14175 • PERMIT NO. l477 CITY OF TIGARD 639-4171 ()ATE 19 BUILDINGPERMIT s1 , ,c.�LOT NO. �� SUBDIVISION P.O. Box 23397, Tigard OR 97223 TAX MAP ' OWNER -,(a1-! r J�u'",�im c c JOB ADDRESS !6600 ..s z-....., �--2- tu-ribac, ( (' BUILDER , r-Cru STATE REG.NO. EXP.GATE BUILDER'S PHONE 2-2 1 _. 0 c 24 ARCHITECT �/u y A R r-moi ' PHONE 2 2 72 -3/ �6 OTHER STRUCTURE 0 NEW 0 REMODEL 0 ADDITION 0 REPAIR 0 MOVE 0 OTHER 0 DEMOLITION ❑ RESIDENCE 0 COMM 0 EDUCATION 0 IND • 0 RELIGIOUS, ❑'ACCESSORY Q GARAGE 0 OTHER 0 FENCE OCCUPANCY "� LAND USE ZONE �. -t BLDG.TYPE -5'-'�' FIRE ZONE ` PLAN CHECK 8Y G2 HEAT R.JIlT. M_a 0 t Fi T Po AJ [2_. A2 — ______—:." -L2.41,-. :=S-.-LT---2�c r^ T L I✓ C -"pc n` i.. l 0,‘.. - Zv „... f mac,>✓-_��•r�, Ft_c_,pa t 1-11-117-...._!--1 "'rz R.L4 l r -RC'.�rJ. SEWER PERMIT I. _ -- - - — - OCC.LOAD FLOOR LOAD HEIGHT ---- NO.STORIES AREA NO.BEDROOMS VALUE BUILDING DEPARTMENT SET BACKS FRONT REAR LEFT SIDE RIGHT SIDE , _Permit v THIS PERMIT IS ISSUED SUBJECT TO THE REGULATIONS CONTAINED IN THE BUILDING CODE,ZONING REGULATIONS AND ALL APPLICABLE CODES AND ORDINANCES.AND IT IS HEREBY AGREED THAT THE PlanCteck ... Z fl WO1U(WILL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND IN COMPLIANCE 20 WITH AU.APPLICABLE CODES AND ORDINANCES.THE ISSUANCE OF THIS PERMIT DOES NOT WAIVE Pt.Ck.Fire c RESTRICTIVE COVENANTS.CONTRACTOR AND SUB CONTRACTORS TO HAVE CURRENT CITY BUSINESS 2 TAX PERMITS.SEPARATE PERMITS REQUIRED FOR SEWER.PLUMBING AND HEATING. State Tax / ! SSOC SOC— Total v 3 5 3- APPLICANT OR AGENT - _ - - - �� POC. Propel. 2_(3t` ADDRESS PHONE — — c1 Receipt No. Bal_Due 7 3- �R Issued By Approved By SDC --- $ OC - 1\Ar RECEIPT # OC - ' DATE PD. OWER CONNECTION s AMOUNT PD. EWER INSPECTION S EWER SURCHARGE S . ]mmenta: I , a - ,C s.,,,( z-, ., J VAt,:_ . .-�4---Az /"*" c9-8� • S COMPUTER LEGEND: © CRT A PROVIDE 6 CRT CABLES WITH 20 FT. EXTRA LENGTH AVAILABLE. CONNECT TO ENGINEERING CPU AT ROOM *130. B PROVIDE 5 CRT CABLES WITH 20 FT. EXTRA LENGTH • AVAILABLE. CONNECT TO ENGINEERING CPU AT ROOM *130 . C PROVIDE 7 CRT CABLES WITH 20 FT. EXTRA LENGTH AVAILABLE. CONNECT TO ENGINEERING CPU AT ROOM ' #130. D PROVIDE 1 CRT CABLE WITH 20 FT. EXTRA LENGTH AVAILABLE. CONNECT TO ENGINEERING CPU AT ROOM *130 . E PROVIDE 1 CRT CABLE WITH 20 FT. EXTRA LENGTH AVAILABLE. CONNECT TO MANUFACTURING CPU AT ROOM *130 . fv-0.1(0E Access o'F GSL 'CttruCJc ( GCtt.crlY-1S OU ti..00 s sof. aoc. di —1 tc#(. uta,ess cr-rt .- wxseE, Notf-D. (WALL- c V.c.'ttorJs seowtJ o N Fior►.- ?L..46.4s , 134 owMtp. — NA.C-) date STASTNY ARCHITECTS �- n •t4 LZ, „Aon.M„n,00.,�A,�.OR ,P,�.80WU7-3116 FLIGHT DYNAMICS, INC. awntryOFFICE/WAREHOUSE REMODEL SD-1 M►ect <'° FLIGHT DYNAMICS, INC. PORTLAND OREGON WILLAMETTE PRINT&BLUEPRINT REFER SHEETS A2.1&A2.2 • s w 1 • -_. t. ■ -L[.L1 ' ' _� --- DOCUM J CONTROL ) . * H - Ft*, /- •'.. -.1 . , /.••':\ 4 A rqus7. . 1-\ �- . Deo - i A , t it- • (4---- . e' - HALL I C�L kr:+r •r 1 1 1 7 OFFICE -1. 111 I,, 0 :) :. rft * r 01La16111101 4.14 Its )® AL LAM ,� - 411 1y, t PA p,*, ' A'6 2- ,,,,...— t( iY.'tt 0 A og.4.41 3tiv" wC(L. c. :* I t, VI i Y.w gg ;'Y.!y.[ 0I LOBBY :: - date STASTNY ARCHITECTS PROrONAL CORPORATION 12'x''"R ' �et• W Trt)nprMAV AVENUE MITE AND.ORLOONn/06•501/1YF�27 FLIGHT DYNAMICS, INC. T drawn, OFFICE/WAREHOUSE REMODEL SD-2 cxoiect n° FLIGHT DYNAMICS, INC. PORTLAND OREGON WILLAMETTE PRINT i BLUEPRINT REFER.SHEET A2.1 • • •*- 20 ti 11. N i I ; I „ 11 )) 1) L OFFICES cLetkovift. GYASTiNct (w) PoLuE.4_ pc...LASS /*wt. cit'i A C.4Xtt)11 Of- c.A..e JUVX..1t00 150)k. Ucce(C10105 , AistNE cpc..1usu*": Fog. owt.ie.a- cpotrocits • rz- 1: t; t 1 I 0 • - . • date 12. STASTNY ARCHITECTS """'"" '" FLIGHT DYNAMICS INC 014 0013171WIIRT ELITIO4110 AVND1•RUM 400•PORTLAND.ORZ3OP1 WY006•5 ,0t7-3I76 • 'drawn by OFFICE/WAREHOUSE REMODEL SD-5 Project n° FLIGHT DYNAMICS, INC. PORTLAND OREGON PRILAMETTE PRINT OLUEPRINT REFER SHEET A2.1 . _ .. . . , . . . .. , _ __ " . - _—_____ —_______ ,.. __ _ • • • I, 11:\ ig'' •C... •-•4,7- i ..(/ ... i 11 .„••••-- f w , .vi '''' ' • 1 • Ir — i, 7 „:0 - a.• 4' . HALL .-- ------1 , ,:-..• I r L:1---: •,--.:.,---_-4 A , .... . WORK/COPY ROOM •.• .... ›- 0 •-, '.., ------- i------ .r----. if / 1 f> H \-s. _ _____ ______- ---, - ..... ... .- --• ,--- .:L...) . ••-• , •\-N.s. 1 ) 4 . --•••••.__ _,./ -'•-,'- . ./ , .'-;•--.--- •-• •-------- I MEN 7---- / date i2,-2,•,-53,(0 STASTNY ARCHITECTS PROFINANOPIAL CORPORATION FLIGHT DYNAMICS) INC. 114 100THWORT NUMOTI ARMS•81/171 400•PORTLAND,ORIDON•71100•00/1,7-31Te drawn by SD--6 OFFICE/WAREHOUSE REMODEL project no FLIGHT DYNAMICS, INC. PORTLAND OREGON WILLAMETTE PRINT&BLUEPRINT REFER SHEET A2.2 • • .‹. ..., 1 .e . __ __ _. . 4 p If ___ - - — - I® STAIR #1 r IIII - OFFICE A ( ID _( \\, E,Db) a .,-_ri_ 4 - Limmii j_ Am: OFFICE ( 2J date STASTNY ARCHITECTS PROM ZONAL CORPORATION Iz•z� 0 114 ELEVENTH AV ,..�.00.PORLAND.OR ItT,Ol.�/l*1 FLIGHT DYNAMICS, INC. drawn) OFFICE/WAREHOUSE REMODEL SD-7 Ir��p project nO FLIGHT DYNAMICS, INC. PORTLAND OREGON %•tt t Cr - 'SHEETREFER A2.2 • • KEYNOTES: /41 . _RE-MOV£ -EXIST ING-VINYb -FLOORI r+ PROVIDE AND INSTALL NEW SHEET VINYL FLOORING WITH CONTINUOUS INTEGRAL 4 INCH HIGH COVED : • SE OVt' >.,X 5T FLOOM VE' IF WITH MFa. ' Ec• 2. -f4;u_tf/ni %. ZA`! • linft.a ssivaivilarirollimaTjs+Tlsrrae._.. • ADD NEW VINYL TILE TO EXPOSED CONCRETE FLOOR AREAS WITH • (2'M $; NEW VINYL TO MATCH EXISTING . ADD NEW WALL BASE AS REQUIRED, TO MATCH EXISTIN . 3. EXIS ING • PMENT 0 • vIN - SHOWN SHADED, TYPICAL. 4. O.F.O. I . (OWNER FURNISHED OWNER INSTALLED) EQUIPMENT. VERIFY AND COORDINATE WITH OWNER FOR CONTRACTOR INSTALLED ITEMS. 5. PROVIDE AND INSTALL NEW EMERGENCY ACID SHOWER BASIN WITH DEEP CURB-{-PI' 'zt AND NEW EM • NCY SHOW R HEAD E•U • ENT. r !'' • '' Z 6. PROVIDE r, 18-1/4"X1:-1/4" INISHED OPEN NG WITH ALuM.EXTRUS\GN CYPCUM O RB`- W:AP ( SILL @ 4 ' -0" (+) AFF. ) FOR O^N FURNI HED A D INSTA L I • • — ' • I I •O COORDINATE SILL HEIGHT WITH EXISTING LAB COUNTER. 7 . ADD 8-1/2" DIA. EXHAUST DUCT TO BE CONNECTED TO OWNER FURNISHED, OWNER INSTALLED FUME HOOD AT LATER DATE. /A8. REMOVE EXISTING sTAiHW VIHYL r4.0. TILE. REPLAce. WITH Hew pMtrc1. 9 . INSTALL NEW METAL STUD WALL WITH GYPSUM BOARD FINISH FROM EXISTING FLOOR AND LAB COUNTER TO EXISTING CEILING . COORDINATE WITH ALL EXISTING UTILITIES . RE- DIRECT EXISTING GAS, AIR, AND VACUUM VALVES TO DARKROOM SIDE ONLY. COORDINATE LOCATION OF NORTH END OF WALL WITH EXISTING LIGHT SWITCHES, THERMOSTAT, ETC. AND EXISTING CEILING DIFFUSERS . 10. PROVIDE AND INSTALL PLYWOOD INFILL PANEL BETWEEN EXISTING SHOWER CURB AND NEW WALL. FLUSH-OUT TOP OF PANEL WITH TOP OF CURB. PAINT TO MATCH CURB . 11 . PATCH EXISTING CEILING EXHAUST DUCT OPENING TO MATCH FINISHED CE ING 2 . PROVIDE AND STALL CURTAIN CEILING TRACK AND r-VU.-t-rE(G,N"CXW\ INDUSTRIAL GRADE CURTAIN. • •e = - - • • • • • • _ MAri E.?IS-r. t M.*t10. ACW...Ir4 'R.AGrTo G •13 . REMOV�i OWER OUT"AL OF EXI TING :INETS W COUNTERTOP. CUT EXISTING COUNTERTOP TO ALIGN WITH NORTH HALF OF CABINETS . VERIFY CLEARANCE FOR OWNER FURNISHED PROCESSING SINK. PROVIDE SUPPORT FOR EXISTING FUME HOOD. date STASTNY ARCHITECTS More/IR/ORAL OORYORATTON 1t �� � .,. �.N„A4T,1.et„n4 •PORTLATro.0 r,,,,O6.=Mr me FLIGHT DYNAMICS, INC. •drawn p°Y OFFICE/WAREHOUSE REMODEL SD-8 oroiect ^° FLIGHT DYNAMICS, INC. PORTLAND OREGON �cnic� WILLAMETTE PRINT&BLUEPRINT REFER SHEET A2.5 III III , Manufacturing/Machine Model Shop: Provide and install chain-hung fluorescent light fixtures as described on drawings, reflected ceiling plans. (Columbia, Keystone or approved) . A Hall #27: Provide and install surface mounted fluorescent light fixtures for hallway lighting illumination only. Alternate Lighting Bid : See sheet A2. 5. Warehouse : Relocate existing chain-hung light fixtures as indi - cated on reflected ceiling plans. / 16. 4 Provide and install smoke detectors in Hall # 1 , Hall #27, a-c4,- Hall #123,4 ,per U. B. C. 3305 ( g. ) exception 5 and connected to an NAt�-ii121japproved fire alarm system installed in accordance with NFPA No. 1gu_ m`o „72-A, 1979 edition. Contractor to verify with local Fire Marshal Letw wto� for quantity and location required. 16. 5 Provide and locate new exit signs per Fire Marshal requirements. /416. 6 Heating : Provide suspended "Co-Ray-Vac" radiant heaters per con- tractor design. FLIGHT DYNAMICS, INC. OUTLINE SPECIFICATIONS - 7 - date STASTNY ARCHITECTS PRO/PPONAL CORPORATION z �� RIIIIeovrnWIerrtXTAM%AVIDATI•MTN.00•PORTLAND.OREGONi?O6•6034147-3178 FLIGHT DYNAMICS, INC. drawn by OFFICE/WAREHOUSE REMODEL SD-12 project no FLIGHT DYNAMICS, INC. PORTLAND. OREGON WILLAMETTE PRINT&BLUEPRINT REFER TO SPECS _____ m,..- A unified Industrial D '� ___ __. ig PAGE f sewerage aste _ - V agency Hillsboro, Or.,97124 disCiia a -J- - __ OF 3 155 N. First Ave.,Suite 270, � - 503 648-8621 1 1.a Applicant Business Name: Flight Dynamics, Inc. Permit No: 111-099-1. 1.b Business/Industrial Park: Monitoring ❑ 2. Address of Premises Discharging Wastewater Nonmonitoring EJ Street: 16600 SW 72nd Avenue (81dg. 110) Renewable Yes ❑ No ❑ City: Portland OR Zip: 97223 Initial ❑ Renewal ❑ SIC No. I.,, 3. Assessor's Map anc Tax Lot Number: 2S1 13AD 1900 Jurisdiction City: Tigard 4. Mailing Address (if different from above) U.S.A. ❑ Street: S%_}e Treatment Plant: City: Zip: Durham 5. Persons to be Contacted About this Permit: (Primary) Name: Gil McCutcheon Title: Engineer Phone: 684_5384 (Alternate) Name: Title: Phone: (Billing) Name: John Desmond Title: President Phone: 684-5384 6. Method Used to Comvte Industrial Sewer Bill (plus commercial fixture count for domestic sewage use): A. It Wastewater consumption or discharge B. ` Wastewater strength 7. Effective Date: September 15, 1989 Expiration Date: September 15, 1994 Revised: December 23, 1991 8. Owner's Representative Print Name ''t : :. r t. Q kke{ cA.tc [..xn.. Title a Signature, 7'--.0, 2 --.'---" Date /* ?/` ' 2... _ 9. Agency Representative Signature , .J"� y.-"., _ Title "wq'` , . .4.bate = /i t 7'2 Mark Bongefi AUTHORIZATION - The above named applicant is hereby authorized to discharge wastewater to the public sewer subject to said applicant's compliance with the Agency's Ordinance No. 9, appropriate R & 0's and Page 2 of this permit and payment of the following fees and charges: Tigard Remit to 10. Fees: A. Permit Fee $ $ B. Connection Charge $ $ C. Plan Review Fee $ $ D. Additional Capacity Fee .64E0U $ 1216.00 $ 243.20 Total $ 1 *•14 $ 243.20 Paid Rev. 2/90 WHITE - USA, YELLOW - Industry, PINK - City, BLUE - Accounting, GREEN - WQL f ,,, [ unified Industrial in ° E ti Ace sewerage J JL aste J_ - 155 N. First Ave.,Suite 270, Hillsboro, Or.,97124 503 648-8621 _ OF 3 Business Name Flight Dynamics, Inc. Permit No: 111-099"1 11. Requirements for Industrial Permit Compliance (If box is checked, that requirement is applicable.) See explanation on reverse side. A. ❑Prior to the 10th of each month, submit monthly monitoring test data to the Agency on approved forms. B. A Report any changes (permanent or temporary) to the premises or operations that significantly change the quality or volume of the wastewater discharge or deviates from the terms and conditions under which this permit is granted. C. ❑Special Requirements: D. ❑Applicable Regulations: E. L Discharge Limitations (Only items checked are applicable.) See Penalties and Charges on reverse side. Applicable Regulation: Pretreatment Resolution and Order ELEMENT OR DAILY MONTHLY ELEMENT OR DAILY MONTHLY CONSTITUENT STORET UNIT MAXIMUM AVERAGE CONSTITUENT STORET UNIT MAXIMUM AVERAGE COD (T) 340 mg/L --' " .. r� Cadmium 1027 mg/L 6•3 COD (T) 340 lbs. Chrome (+6) 1032 mg/L 4 pH 400 Range ""'' --' ' Chrome (T) 1034 mq/L 7.0 TDS 515 mg/L X Copper (T) 1042 mg/L 4.5 TDS 515 lbs. h Lead (T) 1051 mq/L 0.7 )1' TSS 530 mg/L '""" '" " Manganese (T) 1055 mg/L TSS 530 lbs. Manganese (T) 1055 lbs. 1X Oil & Grease 556 mg/L .:ft ° Manganese (S) 1056 lbs. X Cyanide (T) 720 mg/L i..a X Nickel (T) 1067 mg/L •" Sulfide (T) 745 mg/L X Silver (T) 1077 mg/L , Sulfate 945 mg/L X Zinc (T) 1092 mg/L .;. . Sulfate 945 lbs. X Flow 50050 MGD 0.001542 0.001028 Fluoride 951 mg/L Mercury (T) 71900 mg/L Fluoride 951 lbs. Arsenic (T) 1002 mg/L Cyanide(W/D) 718 mg/L 12. Time schedule for compliance (See explanation on reverse side.) Due Date J * Biannual sampling required (June and December ) Rev. 2/90 WHITE - USA, YELLOW - Industry, PINK - City, BLUE - Accounting, GREEN - WQL PERMIT EXPLANATIONS ITEM EXPLANATION 11. Discharge Limitations: Only those items checked must be monitored as required by permit and reported each month, or as directed, to the Agency on an "Industrial User Self-Monitoring Report" form. The report must be postmarked by the 10th of the month following the month being reported to avoid penalty. 12. Time Schedule for Compliance: Time frame in which items listed should be installed or corrected as a condition of the Discharge Permit. INDUSTRIAL WASTEWATER DISCHARGE PERMIT LIMITATIONS--PENALTIES AND CHARGES: When an industrial user is issued a wastewater discharge permit, the user is limited to a specific amount of discharge measured in volume (total monthly discharge volume divided by 30 days) or strength loading. A specific concentration (or mass) amount for certain wastewater constitiuents may also be listed as a discharage requirement/limitation. For industrial users whose monthly average discharge, daily maximum discharge, or for any calendar month exceeds the amounts or limitations allowed by the discharge permit, the following procedure and penalties shall be followed and imposed, respectively: a) First Offense - For the first calendar month in which discharge permit amounts or limitations are exceeded as above-described, a written warning shall be issued stating that if such practice continues, the user will be penalized and may be required to purchase additional discharge capacity or may be required to increase its pretreatment capabilities. b) Second, Third and Fourth Offenses - For the second, third, and fourth calendar months within twelve months of a first offense in which discharge permit amounts or limitations are exceeded as above-described, the user shall be assessed the graduated penalties listed in Table 2 of the current Rates and Charges Resolution & Order. c) Fifth Offense - If discharge permit amounts or limitations are exceeded for a fifth calendar month (within the twelve-month period following the fourth offense) , the user shall be charged for additional discharge capacity and/or be required to install additional pretreatment facilities to increase its pretreatment capabilities. The user shall also be assessed the penalties listed in Table 2. If the user fails to pay for such additional capacity charges and/or fails to submit a schedule for pretreatment improvements within 10 days of receipt of notice of the same, the Agency may cut off sewer and/or water service to the industrial user. Thereafter, if such pretreatment improvements are not constructed in a timely fashion, as determined by the Agency, the Agency shall have the right, with 10-day advance notice to user, to cut off sewer and/or water service to the user. If any industrial user fails, upon demand by the Agency, to supply up-to-date, accurate and complete self-monitoring reports and records, the discharge amount of such user for any calendar month may, in the discretion of the Agency, be deemed to be the water consumption of such user. Page V � 9 Unified Sewerage Agency 1 of 4 Source Control Services Department 400 E.Main,Suite 200 Hillsboro,Oregon 97123 (503)693.4541 (503)648-8874 FAX INDUSTRIAL WASTE DISCHARGE PERMIT Duty to Comply The permittee must comply with all conditions of this permit. Failure to comply with the requirements of this permit may be grounds for administrative action or enforcement proceedings including civil or criminal penalties, injunctive relief, and summary abatements. 1.1a Applicant Business Name Hughes Flight Dynamics, Inc. Location Code (permit#): .11-u99 4 1.1b Business or Industrial Park Name tregm Business Park SIC Number: 1.2 Address of Premises Discharging Wastewater USA Treatment Plant: chain Street 16600 SW 72nd Ave. City State OR Zip Code Q7224 1.3 Assessor's Map and Tax Lot Number 231 13AD 1900 1.4a Mailing Address (If different than above) Street P.O. Box 230609 City Pr,rrlarel State OR Zip Code 97281 1.4b Billing Address Street Same as Mailing Address City State Zip Code 1.5 Persons to be Contacted About this Permit Primary Business Official (Name) McCutcheon Title Facilities Sup' Tel. 684-5884 Alternate Business Official (Name) Title Tel. Billing Information Contact Person (Name) "-al Lewis Title Acct. Pay. Tel.684-5384 Pretreatment System Contact Person (Name) '`> Ritter TitleJPtic Lab Tech. Tel. 684-5384 1.6 Effective Date: 7 13 / /9 Z Expiration Date: `` 5/94 Monitoring Status 0 Non-Monitoring Status C7 1.7 Authorization: The above-named applicant is authorized to discharge industrial wastewater to the public sanitary sewer system in compliance with the Agency's appropriate Resolutions and Orders, and applicable provisions of Federal and State law or regulation, and in accordance with discharge point(s), effluent limitations, monitoring requirements and all other conditions set forth herein. This permit is granted in accordance with the application filed in the office of the Unified Sewerage Agency Source Control Services by the permittee, and in conformity with plans, specifications and data submitted to the Agency by the permittee, as well as payment of the following fees and charges. In no case shall this permit be transferred to another owner, partnership or corporation without prior written notification to the Unified Sewerage Agency Source Control Services. In the event ownership of the permitted industry changes,the owner of this permit shall provide a copy of the existing Industrial Waste Discharge Permit to the new owner or operator. 1.8 Owner's Representative Print Name ,: Ib r R, t1/4.k. eiNr cv Title e ,t t; Signature .�-►�"._-- ., Date t 3 { 1 `f 9 2.. 7 � 1.9 Agency's Representative Print Name Nark Bongen Title ;source Control Investigator Signature 2/11€Y14/7 Date 7 /3 / / =7 Revised 12/91 White-USA,Green-Industry,Yellow-City, Pink-Accounting,Goldenrod-WQL Form 1291-16 sly;to wipes uolleoo-; e;ls 6ulldwes eq;Jepun peieu6lsep uolieool 6ulldwes eq;;e peoelloa eq ilsgs seldws;eIly `spuewpuewe pue 9E L iced ado Op yi!M eouepi000e ul peAJeseJd pue Jeddo;s ssel6 pun©a6 e givA pei;l;saeule;uoo ssel6 ul pe;aelloo eq!legs seldwes geJ6 eqi °dep 6ul;e.iedo eqi JBna peloelloo eq!Heys seldwes geA6 eieJosip Jnod eseeJo pue Ilo '(mol JO ON) esjids eqi po ieed eq;le Hd eyi 6uRou pue 'seinulw g 1 ueq;Je;e016 e6ueJ Hd;o;no suolsanaxe eq;6ulpou 'pJ000J ilego dols yd eqi 1a AJewwns dlep e epnoad -Hd •dpu6eiul eidwes ensu op epxoipdq wnlpos slim pe ueseJd uses seg yolgM Jeule;uao Je6Jel e o;ul peusodwoo pue pegelloo eq pegs pue lw Do; ueq;ssel eq;ou pegs ionblle goed °sweeJiseiseM olpsswop Jo sesseooad Jegpo gppM 6ulxiw op Joud lnq 'sseooAd;oni;sap eplued0 eq;Jells;ulod e wJOJI pe;oelloo eq!legs seldwes eq! °dep 6ulleaedo eyi Jeno peioelloo eq Ileus seldwes gea6 eleooslp mad-eplued3 °s;uewpuewe pus '9£1 lied WO of gilts eouepa000e ul pewJoped eq!legs slsdleue pus 64dwes siuenplpsuoo Jey;o Ile Jo;pesn eq pegs 6ulldwes ellsodwoo leuollJodoJd-Mol;Jnoq-pe • solue6Jo ellie oA - apAns - eseeJ6 pue!Ip sloueyd le;ol eplued9 • Hd - .1o;pesn eq ;snw seidwes geJ6 Jno;;o wnwlulw v • :suofleisdo A iep;o enl;elueseJdeJ eq(legs 6ulldwes eqi 'awl;Jo Mal;Jol pie6eJ;nogoA`sesiulw S 1 uegi ssel of pe;oelloa eidwes lenpinipul ue sl eidwes gs3J� v °sJepll q eq!legs ewnlon eidwes e;Isodwoo Jnoq p leap! uy s;uewpuewe pue 9E1 iJel adO Otr ap 6ulpJ000e pe&JesoJd pue pe;lsodwoo aq hew seldwes °polaed Jnoq e Jena pepoelloo sewnlon lenbe to mpg Jed eidwes 1 ;o wnwlulw a :JO 'peuolpJodoad-Mold.e6Jegosip dllep;o en!pe;ueseJdeJ eidwes y sldwes eilsodwoo Jnoq°p£ `peulwgns silnsoJ leolid!eue eq;uo peseq 6ulldwes 10 douenbeJI eqi eseeIou!Jo eonpeJ dew doue6y eqi 'peupeds eslauey;o sseIun °sle;ew lupin;eq!legs slsdleue sew !iv `suoi;eln6ea pue salnH;uewieeJieJd eg;u!is!1 iuslnfiod diiJo!id (NT u!pef;loeds solue6Jo olxo;eq;to pee Jol"Ow 10°0 ueq;Jeleej6 semen lie 10 uollewwns eq;s! (oil)solue6J0 oval lelol :seioN `seulfpeep IeJepe;elgeopdde due puodeq eiep eouelldwoo eqi pue;xe lou Aew selnpegos eoue 11dwo0 °elnpegos souelidwoo elgealldde Aue pus 'sp iepue;s;uew;eeJieJd to uogeloln Jed Asp Jed 000'11155e! rep segleued feulwuo Jo limo wnwlxew eq;ssesse Jo)fees Aew doue6y eta -sons doue6y of pequosep se penssl eq Aew sel;!sued Ipnlo to eolp0N e 'suolpsfoln egp 10 uolmedai;o suoReolpui eq o;saeedde eJegp 11 Jo`dlsnolneid uodn peei6e Jo °doueby ey;dq peuluiiepep se ewli;o polled elgeuoseei e ulgilM pe;osJJoo you eJe suolleloln pJepueis puew;eeuiead A spinseJ pue selllnlioe 6uuol!unw to spJooeA Aue steed £;o wnwlulw e Jo;u!eieJ a;pealnbeJ sl uol oes slq;u! pegsiigeise spuewejinbeJ 6ufpjodeJ eqi of iosFgns Jesn le!Jisnpu!Auy °sJs;ew MOI;pus Hd Jo16oi uol;eJglie0 °sesdleue yons 10 slpnsaj eyi. . 'peso senblugoei/spoq;ew leollAleue eqi 'seshleue eq;peuuoped ogm • apewJoped eJBM sesdleue eqi seiep eqi 'seldwes eyi 6upe1 suosied ye;o seweu Jo ewsu eyp pus '6ulldwes;o owl;pus poglew 'eoeld poexe'amp eqi . .seldwes lie Jo;pepnioui eq ileus spiooeJ sons °((a) E1°£ob Aldo op) selilnl;oe 6upoi,uow Aue11104 6ulilnsei uoliswJolul lie 10 spoo9J ulepulew !legs spueweJlnbeJ 6uipodeJ oi;oefgnsJesn le!.gsnpui Auy siuew®Jfrzbe8 bu{ldwes pus suolsifwn a6JeyasIQ 1 ~ « Discharge Limitations and Sampling Requirements Any industrial user subjecto reporting requirements shall maintain records of all information resulting from any monitoring activities(40CFR 403.12 (o)). SUch records shall be included for all samples: • The date,exact piao*, method and time of aamp||ng, and the name or names of all persons takin | the oample- ^ The dates the analyses were performed. o Who performed the analyses. ° The analytical methods/techniques used. • � ° The results of such analyses. • Calibration log for pH and flow meters. Any industrial user subject to the reporting requirements established in this section is required to retain for a minimum of 3 years any records of monitoring activities and results. If pretreatment standard violations are not corrected within a reasonable period of time as determined by the Agency, or agreed upon previously, or if there appears appears to be indications of repetition of the violations, a Notice of Civil Penalties may be issued as described in Agency rules. The Agency may seek or assess the maximum clvii or criminal penalties of at least$1,000 per day per violation of pretreatment standards, and any applicable compliance schedule, Cornpli- ance schedules may not extend the compliance date beyond any applicable federal deadlines. Notes: Total Toxic Organics (TTO) is the summation of all values greater than 0.01 mglL for each of the toxic organics specified in the Priority Pollutant List in the Pretreatment Rules and Regulations. Al! ' taIs analysis shall be for total tals, unless otherwise specified. The Agency may reduce or increase the frequency of sampling based on the analyticalresults submitted 24 hour composite sample A sample representative of daily discharge:Flow-proportioned, or;a minimum of 1 sample per hour of equal volumes collected over a 24 hour period. Samples may be composited and preserved according to 40 CFR Part 136 and amendments, An ideal 24 hour composite sample volume shall be 4 liters. A"Grab"sample is an individual sample collected in less than 15 minutes, without regard tor flow or time. The sampling shall be representative of daily operations: • A minimum of four grab samples must be used for - pH - Cyanide - Total phenols • ' Oil and grease ' Sulfide - Volatile organics • 24-hour flow-proportional compostte sampling shall be used for all other constituents , Sampling and analysis shall be performed in accordance with 40 CFR Part 136, and amendments, Cyanide- Four discrete grab samples shall be collected over the operating day. The samples shall be collected from a point after the Cyanide Destruct process, but prior to mixing with other processes or domestic wastestrearns. Each aliquot shall not be less than 100 ml and shall be collected and composited into a larger container which has been preserved with sodium hydroxide to insure sample integrity. pH - Provide a daily summary of the ph strip chart record, noting the excursions out of pH range greater than 15 minutes, and noting the pH at the peak of the spike (high or low). Oil and Grease- Four discrete grab samples shall be collected over the operating day. The grab samples shall be collected in glass containers fitted with a ground giass stopper and preserved in accordance with 40 CFR Part 136 and amendments. All samples shall be collected at the sampling location designated under the Sampling Site Location section of this permit. � Page Unified Sewerage Agency 3 of 4 Source Control Services Department 400 E.Main,Suite 200 Hillsboro,Oregon 97123 (503)693-0541 (503)648-8874 FAX Hughes Flight Dynamics, Inc, K � Location Code(Permit#): t11-099-1 Discharge Limitations and Sampling Requirements The following monitoring requirements shall apply to the wastewater discharge from the permitted facility: Parameter Storet Units* Daily Max. Monthly Avg. Sampling Freq. Type of Sample pH Max !,_t'r+ 10.0 NA Biannual Grab pH Min 401 6.5 NA Biannual Grab Cr(+6) 1034 * - NA Biannual Grab Cr(T) 1034 * 7.0 NA Biannual Grab Flow 50050 GPD 1542 1028 Monthly Meter Reading ApRlicable Regulations: 40 CFR Part 403 In the event compliance monitoring shows any permitted constituent to be approaching the limit, additional sampling and testing will be required to assure continued compliance with 40 CFR Part 403. "mg/L,unless otherwise specified Owner/Representative Signature Agency Signature Revised 12/91 White-USA,Green-Industry,Yellow-City, Pink-Accounting,Goldenrod-WQL Form 1291-18 Discharge Limitations and Sampling Requirements Any industrial user subject to reporting requirements shallmaintain records of all information resulting from any monitoring activities (40 CFR 403.12 (a)). Such records shall be included for all samples: • The date,exact place, method and tl of sampling,and the na or names of all persons taking the samples. • The dates the analyses were performed, • Who performed the analyses. • The analytical methods/techniques used. • The results of such analyses. Calibration log for pH and flow meters, <y F ioustriai user subject to the reporting requirements established in this section is required to retain for a minimum of 3 years any records of monitoring activities and results. If pretreatment standard violations are not corrected within a reasonable period of time as determined by the Agency, or agreed upon previously, or if there appears to be indications of repetition of the violations, a Notice of Civil Penalties may be issued as described in Agency rules, The Agency may seek or assess the maximum civil or criminal penalties of at least$1,000 per day per violation of pretreatment standards, and any applicable compliance schedule. Compli- ance schedules may not extend the compliance date beyond any applicable federal deadlines. Notes: Total Toxic Organics (TTO) is the summation of all values greater than 0.01 mg/L for each of the toxic organics specified in the Priority Pollutant List in the Pretreat =-nt Rules and Regulations. All metals analysis shall be for total ° tals, unless otherwise specified. . The Agency may reduce or increase the frequency of sampling based on the analytical results submitted, 24 hour composite sample A sample representative of daily discharge:Flow-proportioned, or;a minimum of 1 sample per hour of equal volumes collected over a 24 hour period. Samples may be composited and preserved according to 40 CFR Part 136 and amendments. An ideal 24 hour composite sample volume shall be 4 liters. A"Grab'sample is an individual sample collected in less than 15 minutes, without regard for flow or time. The sampling shall be representative of daily operations: • A minimum of four grab samples must be used for - pH - Cyanide Total phenols Oil and grease Sulfide - Volatile organics • 24-hour flow-proportional composite sampling shall be used for all other constituents • Sampling and analysis shall be performed in accordance with 40 CFR Part 136, and amendments. Cyanide-Four discrete grab samples shall be collected over the operating day. The samples shall be collected from a point after the Cyanide Destruct process, but prior to mixing with other processes or domestic wastestreams, Each aliquot shall not be less than 100 ml and shall be collected and composited into a larger container which has been preserved with sodium hydroxide to insure sample integrity. pH-Provide a daily summary of the ph strip chart record, noting the excursions out of pH range greater than 15 minutes, and noting the pH at the peak of the spike (high or low). Oil and Grease- Four discrete grab samples shall be collected over the operating day. The grab samples shall be collected in glass containers fitted with a ground glass stopper and preserved in accordance with 40 CFR Part 136 and amendments. All samples shall be collected at the sampling location designated under the Sampling Site Location section of this permit. V _f Page Unified Sewerage Agency 4 of 4 Source Control Services Department 400 E.Main,Suite 200 Hillsboro,Oregon 97123 (503)693-4541 (503)648-8874 FAX Sample Site Location Location of sample sites indicated in the drawing are the official Agency and industrial sample collection loca- tions, including the cyanide sampling point, if required. All samples tested for permit constituents must be obtained from these sites. Business Name HughP s Fl 1ght Dynamic's USA Permit#/Location Code 111-099-1 f } r ►nc� ci cif LA to j1 e 7714. L . , i!f K Owner/Representative Signature Agency Signature Revised 12/91 White-USA,Green-Industry,Yellow-City, Pink-Accounting,Goldenrod-WQL Form 1291-19 Discharge Limitations and Sampling Requirements Any industrial user subject to reporting requirements shall maintain records of all information resulting from any monitoring activities(40 CFR 403.12 (a)). Such records shall be included for all samples: • The date, exact place, method and ti r of sampling, and the name or names of all persons taking the samples. • The dates the analyses were performed, • Who performed the analyses, • The analytical methods/techniques used. • The results of such analyses. • Calibration log for pH and flow meters. • Any industrial user subject to the reporting requirements established in this section is required to retain for a minimum of 3 years any records of monitoring activities and results. If pretreatment standard violations are not corrected within a reasonable period of time as determined by the Agency, or agreed upon previously, or if there appears to be indications of repetition of the violations, a Notice of Civil Penalties may be issued as described in Agency rules. The Agency may seek or assess the maximum civil or criminal penalties of at least$1,000 per day per violation of pretreatment standards, and any applicable compliance schedule. Compli- ance schedules may not extend the compliance date beyond any applicable federal deadlines. Notes: Total Toxic Organics (TTO)is the summation of all values greater than 0.01 mg/L for each of the toxic organics specified in the Priority Pollutant List in the Pretreatment Rules and Regulations. All metals analysis shall be for total tals, unless otherwise specified, The Agency may reduce or increase the frequency of sampling based on the analytical results submitted, 24 hour composite sample -A sample representative of daily discharge:Flow-proportioned, or;a minimum of 1 sample per hour of equal volumes collected over a 24 hour period. Samples may be composited and preserved according to 40 CFR Part 136 and amendments. An ideal 24 hour composite sample volume shall be 4 liters. A"Grab"sample is an individual sample collected in less than 15 minutes,without regard for flow or time. The sampling shall be representative of daily operations. • A minimum of four grab samples must be used for pH - Cyanide - Total phenols - Oil and grease - Sulfide - Volatile organics • 24-hour flow-proportional composite sampling shall be used for all other constituents • Sampling and analysis shall be performed in accordance with 40 CFR Part 136, and amendments, Cyanide-Four discrete grab samples shall be collected over the operating day. The samples shall be collected from a point after the Cyanide Destruct process, but prior to mixing with other processes or domestic wastestreams. Each aliquot shall not be less than 100 ml and shall be collected and composited into a larger container which has been preserved with sodium hydroxide to insure sample integrity. pH -Provide a daily summary of the ph strip chart record, noting the excursions out of pH range greater than 15 minutes, and noting the pH at the peak of the spike (high or low), Oil and Grease- Four discrete grab samples shall be collected over the operating day. The grab samples shall be collected in glass containers fitted with a ground glass stopper and preserved in accordance with 40 CFR Part 136 and amendments. All samples shall be collected at the sampling location designated under the Sampling Site Location section of this permit. Ulorn Page Unified Sewerage Agency 1 of 7 Source Control Services Department 400 E.Main,Suite 200 Hillsboro,Oregon 97123 (503)693-4541 BEST MANAGEMENT PRACTICE (503)648-8874 FAX INDUSTRIAL WASTE DISCHARGE PERMIT Permit No: 111-099-. Treatment Plant: Map/Tax No: .S1 13A) 1900 SIC No.(s): 381L Effective Date: Expiration Date: 09/15/99 In accordance with the provisions of Unified Sewerage Agency's Resolution & Order 92-60, or as amended, ('Permittee's name) 1O60U yi , Port14, . 97224 (Permittee's location address) (herein known as Permittee) is hereby authorized to discharge industrial wastewater from the above identified facility, and through the discharge points identified in Section 1.A., into the Unified Sewerage Agency's sanitary sewer system in accordance with the conditions set forth in this permit. Compliance with this permit does not relieve the Permittee of its obligation to comply with any or all applicable pretreatment regulations, standards or requirements under local, State, and Federal laws, including any such regulations, standards, requirements, or laws that may become effective during the term of this permit. Noncom- pliance with any term or condition of this permit, or any compliance schedule, shall constitute a violation of the Unified Sewerage Agency's sewer use ordinance(s),and may be grounds for administrative action or enforcement proceedings including civil or criminal penalties, injunctive relief, and summary abatement. In no case shall this permit be transferred to another owner, partnership or corporation without prior written permission from the Agency. Permittees wishing to transfer a permit to a new owner must notify the Agency in writing at least 60 days in advance of any anticipated transfer. Written notification must include information by the new owner which certifies the new owner's intent not to change the facility's operations or processes, identifies the specific date on which the transfer is to occur, and acknowledges full responsibility for complying with the wastewater discharge permit. The new owner/operator shall be provided a copy of this permit by the previous owner/operator. Failure to provide advance notice of a transfer renders the wastewater permit voidable on the date of the owner- ship transfer. If the Permittee wishes to continue to discharge after the expiration date of this permit, an application may be required for renewal a minimum of 90 days prior to the expiration date, in accordance with the requirements of the Agency's Resolution & Order 92-60, Sections 3.03 and 3.11, or as amended. By: P„ tt,„€ (4-- Source Control Manager Issued this day of , 19 Revised 09/93 White-USA, Green-Industry, Canary-City, Pink-Accounting, Goldenrod-WQL Form 0993-48 U A4 Page 9 Unified Sewerage Agency 2 of 7 Source Control Services Department 400 E.Main,Suite 200 Hillsboro,Oregon 97123 (503)693-4541 SECTION 1 (503)6488874 FAX BEST MANAGEMENT PRACTICES- REQUIREMENTS 1.A. During the effective period of this permit,the Permittee is authorized to discharge process wastewater from the outfalls listed below: Outfall Number Description(Refer..to d..ag.ram.on Page 80.18.) 001 dolo Zaphic Fs I t e K C t t: non-contact cooling water from lasers ; RODI reetect 002 The discharge(s) from the above identified outfalls must be maintained at all times through the Best Management Practices (BMP) described below. If, upon inspection of the facility by Agency staff, it is determined that BMP's have not been complied with;or if upon the collection and analysis of a wastewater sample,pollutants of concern exceed established operating limits, increased monitoring and/or additional pretreatment may be required. DESCRIPTION OF BEST MANAGEMENT PRACTICES 1 . Perfgorm pretreatment procedures submitted August 19, 1994 on all Optic' s lab wastewaters a; necessary to ensure compliance u,=.i t3> dis6tiarge requirements and constituent limits . ' . Ensure that all flow meters are in proper working condition . 1.B. Any collection, preservation, handling and laboratory analyses of samples for compliance monitoring shall be performed in accordance with 40 CFR Part 136, and ammendments thereto, unless specified otherwise in this permit. Analytical techniques for additional pollutants not contained in Part 136 must be performed by using validated analytical methods approved by EPA and the Agency. Revised 05'83 White-USA, Green-Industry, Canary-City, Pink-Accounting, Goldenrod-WOt. Form 0883-48 uf Page Unified Sewerage Agency 3 of 7 Source Control Services Department 400 E.Main,Suite 200 Hillsboro,Oregon 97123 (503)693-4541 (503)648-8874 FAX SECTION 1 (continued) 1.C. Per 40 CFR Part 403.5 (a), (b) and Unified Sewerage Agency's Resolution & Order 92-60, Sections 2.01 and 2.02, or as amended,the Permittee shall not discharge wastewater containing any of the following prohibi- tions from any of their permitted outfalls: GENERAL DISCHARGE PROHIBITIONS The Permittee shall not discharge, cause or permit to be discharged, directly or indirectly, any pollutant or wastewater which will cause interference or pass through at the treatment plant(s). These general and specific prohibitions apply to all users of the Agency's wastewater system whether or not they are subject to Categorical Pretreatment Standards or any other national, state or local pretreatment standards-or requirements. SPECIFIC PROHIBITIONS The Permittee may not discharge to the sanitary sewer system any of the specific prohibitions as identified in 40 CFR Part 403.5(b) and Unified Sewerage Agency's Resolution & Order 92-60, Section 2.02, or as amended. SECTION 2 REPORTING REQUIREMENTS 2.A.1. Accidental Spill Prevention Plan (ASPP) -An ASPP may be required for notification of potential problems. This plan, per the requirements in 40 CFR Part 403.8(f), is necessary to assess the emergency planning of the Permittee in case of a slug load or chemical spill in the facility. The report must address the steps the Permittee will take to keep spilled or unused chemicals out of the sanitary/storm sewers, either by intentional or accidental release, and include notification procedures to the Agency. 2.A.2. Spill Notification - In the event of any spill, slug discharge or problem discharge into the Agency's treat- ment system, the permittee shall immediately (within 2 hours) notify the Agency by telephone of the incident and shall provide such information as may be required at that time to assess the impact of the incident on the Agency's system or on water quality. Within five (5) business days following any such incident,the permittee shall submit to the Agency a detailed written report containing a description of the incident and its cause; its location within the permittee's facility; exact dates/times of the period of problem discharge and, if not yet cor- rected,the anticipated time the incident is expected to end; and, steps taken (or planned) to correct the incident and to reduce, eliminate and prevent occurrences of future incidents. A problem discharge means any upset, slug discharge, spill or accident which results (or may result) in a dis- charge into the Agency's treatment system of a prohibited substance;or of a regulated substance in excess of permit limits and which may: (a)cause interference or pass through at the treatment plant;or(b)contribute to a violation of any requirement of the Agency's NPDES permit; or(c)cause violation of any State or Federal water quality standard. During normal business hours, notifications may be made by calling the Source Control Division at 693-4541. Emergency notifications may be made after hours/weekends/holidays by calling the duty officer at 784-6229. 2.B. The Permittee shall immediately report any significant changes(permanent or temporary)to the premises or operations that cause substantial changes in production, volume or character of the wastewater discharge, or Revised 09/93 White-USA, Green-Industry, Canary-City, Pink-Accounting, Goldenrod-WQL Form 0993-50 r Page Unified Sewerage Agency 4 of 7 Source Control Services Department 400 E.Main,Suite 200 Hillsboro,Oregon 97123 (503)693-4541 (503)648-8874 FAX SECTION 2 (continued) deviates from the terms and conditions of this permit, per the requirements in 40 CFR Parts 403.12(j) and 403.6(c)(7). Unless emergency conditions prevail, the Agency requires that changes be reported prior to being implemented. At least 90 days prior to commencement of a new discharge, existing users which have changed operations or processes shall be required to submit an Industrial Wastewater Discharge Permit Application per the require- ments in Agency Resolution & Order 92-60, Section 3.03. All reports and notifications shall be submitted to: Unified Sewerage Agency Source Control Division 400 East Main St., Suite 200 Hillsboro, OR 97123 (503)693-4541 FAX(503) 693-4884 See requirements in Section 3 2.C. Notification from the Permittee is required to the Agency, the EPA RCRA Director, and the Oregon State Hazardous Waste Director within 90 days of the effective date of a published RCRA ruling, of a discharge(or changed discharge) of either a listed or characteristic hazardous waste to the sanitary sewer, per the require- ments in 40 CFR Part 403.12(p). The Agency requests notification even if the results of the hazardous material sampling are submitted on self-monitoring reports (Periodic Compliance Reports). 2.D. An "Upset", and an affirmative defense for such, shall not be allowed under circumstances where non- compliance has been caused by operational error, improperly designed or inadequate treatment facilities, lack of preventative maintenance, or careless or improper operation. In case of an upset or upon reduction, loss or failure of its treatment facility, the permittee shall control production and/or all discharges to the extent necessary to maintain compliance with applicable pretreatment standards until treatment is restored or an alternative method of treatment is provided. This requirement also applies in situations where the primary source of power for the treatment facility is reduced, lost or fails. 2.E. Bypass: the intentional diversion of one or more wastestreams or processes from any portion of the permit- tee's treatment facility is prohibited per the Agency's Industrial Sewer Use Rules and Regulations R&O 92-60. Revised 09/93 White-USA, Green-Industry, Canary-City, Pink-Accounting, Goldenrod-WQL Form 0993-51 / • tift4 Page Unified Sewerage Agency 5 of 7 Source Control Services Department 400 E.Main,Suite 200 Hillsboro,Oregon 97123 SECTION 693-1541 SECTION 3 (503)648-8874 FAX NOTIFICATION & RECORDKEEPING REQUIREMENTS 3.A. Any Permittee subject to reporting requirements in 40 CFR Part 403.12 shall retain and preserve all records, books, documents, memoranda, reports, correspondence and any and all summaries thereof, relating to monitor- ing, sampling and chemical analyses made by or on behalf of an the Permittee in connection with its discharge. Such records shall be subject to review by the Agency, and shall include for all samples: 1) The date, exact place, time, and methods of sampling or measurements, and sampling preservation techniques; 2) Who performed the sampling or measurements; 3) The date(s) the analyses were performed; 4) Who performed the analyses; 5) The analytical techniques or methods used;and 6) The results of such analyses. 3.B. The Permittee shall retain for a minimum of three years all such records defined in Section 3.A. above, and shall make such records available for inspection and copying by the Agency,the DEQ Director and the EPA Regional Administrator. This period may be extended by the request of the Agency at any time. All records that pertain to matters that are the subject of special orders or any other enforcement or litigation activities brought by the Agency shall be retained and preserved by the permitee until all enforcement activities have concluded and all periods of limitation with respect to any and all appeals have expired. 3C. For any information faxed to the Agency, the original shall be retained on the permittee's premises for a minimum of three (3) years;or the original shall be mailed to the Agency as a follow-up to the fax. SECTION 4 STANDARD CONDITIONS 4.A. Permit Modification The Agency reserves the right to amend any Wastewater Discharge Permit issued hereunder for good cause including, but not limited to the following: 1) To incorporate any new or revised local, State or Federal pretreatment standards or requirements; 2) Alterations or additions to the Permittee's operations, processes, discharge volume or characteristic not considered in drafting the original permit; 3) A change in any condition at the Permittee's facility or the POTW requiring a temporary or permanent reduction or elimination of the authorized discharge; 4) Information indicating that the permitted discharge poses a threat to the POTW's collection or treatment systems, personnel or receiving waters; 5) Violation of any terms or conditions of the permit; 6) Misrepresentation or failure to disclose fully all relevant facts in the permit application or any required reporting; 7) Revision of, or a grant of variance from applicable categorical standards per 40 CFR Part 403.13, 403.6(e)and 403.15; 8) To correct typographical or other errors in the permit; 9) To reflect transfer of the facility ownership and/or operation to a new owner/operator; Revised 09/93 White-USA, Green-Industry, Canary-City, Pink-Accounting, Goldenrod-WUL Form 0993-52 A Page Unified Sewerage Agency 6 of 7 Source Control Services Department 400 E.Main,Suite 200 Hillsboro,Oregon 97123 (503)693-4541 (503)648-8874 FAX SECTION 4 (continued) 10) Upon request of the permitted Industrial User,provided the request does not violate any requirements, standards, laws, rules or regulations; 11) To incorporate any new or revised constituent limit resulting from the Agency's reevaluation of its local limits. 4.B. Dilution Prohibition The permittee shall not increase the use of potable or process water in any way for the purpose of diluting a discharge as a partial or complete substitute for adequate treatment to achieve compliance with the standards set forth in this discharge permit or any Agency ordinances, or in lieu of proper disposal of any material as solid waste. The Agency may impose mass limitations on dischargers which in its judgement appear to be using dilution to meet applicable pretreatment standards or requirements of this section, or in cases where the imposi- tion of mass limitations is otherwise deemed appropiate by the Agency. 4.C. Representative Sampling Samples and measurements taken as required by this permit shall be representative of the volume and nature of the monitored discharge. All samples shall be taken at the monitoring points specified in this permit, and unless otherwise specified, before the permitted discharge joins or is diluted by any other wastestreams, body of water or substance. All equipment used for sampling and analyses must be routinely calibrated, inspected and maintained to ensure its accuracy. Monitoring points shall not be changed without notification to, and approval from the Agency. 4.D. Inspection and Entry The Agency may inspect the facilities of any Permittee to determine compliance with the requirements of the Agency rules and regulations. The Permittee shall allow the Agency or its representatives to enter upon the premises of the Permittee at all reasonable hours and without prior notification by the Agency, for the purposes of inspection, sampling, and records examination and copying. The Agency shall have the right to set upon the Permittee's property such devices as are necessary to conduct sampling, inspection, compliance monitoring and/ or metering operations. 4.E. Proper Disposal of Sludges/Spent Chemicals The disposal of pretreatment sludges and spent chemicals shall be done in accordance with Section 405 of the Clean Water Act (CWA) and Subtitles C & D of the Resource Conservation & Recovery Act (RCRA), and any state hazardous waste requirements. 4.F. Falsifying Information/Tampering With Monitoring Equipment Knowingly making any false statement on any report or other document required by this permit, or knowingly rendering any monitoring method or device inaccurate, may result in punishment under criminal laws of the Agency, as well as being subject to civil penalties and relief. 4.G. Emergency Suspension of Services/Revocation of Permit The Agency may suspend the wastewater permit of a Permittee,whenever necessary in order to stop an actual or threatened discharge which reasonably appears to present or cause an imminent or substantial endangerment to the health or welfare of persons, interferes with the operation of the Agency's wastewater system, or which present or may present an endangerment to the environment. In addition to further penalties and remedies in any Ordinances or R&O, the Agency may terminate the wastewa- ter permit of any Permittee for violations of any Ordinance, R&O, or discharge permit condition. Revised 09/93 White-USA, Green-Industry, Canary-City, Pink-Accounting, Goldenrod-WQL Form 0993-53 yorA Page Unified Sewerage Agency 7 of 7 Source Control Services Department 400 E.Main,Suite 200 Hillsboro,Oregon 97123 (503)693-4541 SECTION 5 (503)648-8874 FAX SPECIAL CONDITIONS 5.A. Additional Reporting 1. An Accidental Spill Protection Plan (ASPP)is due no later than: NA . This plan is required to assess the emergency planning of the Permittee in case of a chemical spill in their facility per the requirements in 40 CFR 403.8(f). 2. Additional Provisions or Reporting BEST MANAGEMENT PRACTICE INDUSTRIAL WASTE DISCHARGE PERMIT SAMPLE SITE LOCATION Permit No: III-099- Issue Date: It: .49 The following outfall sample sites are the official Agency and Permittee sample collection locations. A separate cyanide sampling point is included, if required. All samples collected for compliance monitoring must be obtained from these sites. If vastewater samples are to be obtained they shall be taken from the sample clean-out in the NE side of the laboratory . Revised 09/93 White-USA, Green-Industry, Canary-City, Pink-Accounting, Goldenrod-WQL Form 0993-54 ! • STASTNY 1 ARCHITECTS PROFESSIONAL CORPORATION 614 SOUTHWEST ELEVENTH AVENUE•SUITE 400•PORTLAND,OREGON 97205•503/227-3176 January 15 , 1987 Mr. Al Caliendo Flight Dynamics, Inc . 16600 S.W. 72nd Avenue P. O. Box 230609 Portland, OR 97224 Re : Flight Dynamics , Inc . - #8616 Building Permit Plan Review Dear Al : Please find attached, the letter of plan review for the Flight Dynamics, Inc. tenant improvements from the City of Tigard. As you will notice, the plans have been approved with the noted conditions, items 1 through 12. All the items appear to be familiar and in keeping with what we 've discussed in the past few weeks . However, there are two items I wish to draw your attention to. Item 8 shall need confirming at existing conditions : the main entry doors at Lobby #101 and the exterior doors at Vestibules #30 and #31, (unless you choose to remove them as discussed) will require free acting door leafs and not more than one operation for unlatching any leaf. If flushbolts exist, they are required to be automatic . The Contractor is presently reviewing this condition and will contact us accordingly. The double doors from Machine Shop #6, Simulation/Check-Out #15, and Lunch Room #25 are acceptable as indicated on the drawings with the following conditions : 1) The inactive door leaf shall not have any hardware on its ' exposed surface; 2) an exit shall be applied to the active leaf (this can also be accomplished by locating a directional exit sign over the active door; 3 ) the inactive leaf shall be as inconspicuous as possible, to distract attention when exiting . Item 12 remains to be the only issue unresolved. The City of Tigard is firm on their stand requiring the provision of handicapped accessibility. The building official, Brad Roast, and the Contractor, Howard Green, have met out at the site to review handicapped access to the building. The existing conditions were found unacceptable without the addition of a code approved ramp. III 411 f Mr. Al Caliendo January 15 , 1987 Page Two We will proceed to propose alternative ramp designs to meet the accessibility requirements and submit to you and PacTrust for review and approval . We suggest you proceed to obtain final or temporary occupancy permit depending on the City of Tigard ' s position on this matter in order to avoid any offsets to your move-in schedule. We will continue to be in contact with PacTrust to determine if there are other alternatives to solving handicapped accessibility to your facility. Please call if you have additional questions or concerns . Sincerely, STASTNY ARCHITECTS P.C. 012 / -arry� . Dinihanian Project Architect HMD: js cc : Brad Roast ( City of Tigard) Howard Green (H.L. Green Co. ) Leon Hartvickson (PacTrust) • STASTNY ARCHITECTS PROFESSIONAL CORPORATION 614 SOUTHWEST ELEVENTH AVENUE•SUITE 400•PORTLAND.OREGON 97205.503/227-3176 TRANSMITTAL TO: V S. 1(2-` �\1Y N PROJECT t--'GI K�i t /(4Q�LI) /C>► � �y� .� (-- - PROJECT NUMBER 1/ 1 1U _ 5•W• Rleth Ave. J�u�'t'-E ZGV C) DISTRIBUTION GKi'1 0111114141.0-Ta,` 1-> e5 eR. 170a-1L A, q'i2O4 TON ATt ) F. - G+spE..P21Itz..1-tILL Ftr.1).•(niAcIntc.'S- Cay..,Ewa WE ARE SENDING THE FOLLOWING MATERIALS D HEREIN D SEPARATE COVER NUMBER DESCRIPTION ACTION OF COPIES OF ITEM(S) DATED REQUESTED a 11 �t �I )C / (1 DF ti-•s")•tfv U151bkrre- 'CU suPC�- .M 7 AP- 4.)I klciS SO?,• Co -rte., - Ic*e5 SD -t 444-v SD-12 . A5 [ ezot Piz-o\ toy P- .v is iris 1N0 L MED ot,) V "CC.E-€5 f IICL-OQO --O REMARKS - - DATE A'60" PAGE OF ` • 111 i January 9, 1987 CITY OF ■ IGA RD OREGON 25 Years of Service 1961-1986 Mr. Harry Dinihanian Stastny Architects 614 SW 11th Avenue, Suite 400 Portland, OR 97205 RE: Plan Review 16600 SW 72nd Flight Dynamic, Inc. Dear Mr. Dinihanian: The Plan Review for the proposed tenant space modification at the above referenced address has been completed. The Plans are approved with the following conditions: i 1. Hallways 27, 101, 102, 127, 123, 201, 202, 205, 218, 219, 221, and 223 are required to be protected corridors. Per our discussions, a smoke detection system complying with NFPA 72-A, 1979 edition will be acceptable (Sec. 3305G exception 5 UBC) . �2. All doors opening into stairwells 1 and 2 must be 20 minute (labeled) firedoor assemblies with self-closers and smoke gaskets. 3. The vestibules 30 and 31 shall have deluge sprinkler heads on each side of the windows and doors opening into the vestibules from the first floor offices (in lieu of one hour construction, wire glass, 20 minute fire assembly) . The door shall be equipped with a smoke gasket. An optional solution of removing the double leaf doors between the vestibule and the exterior is acceptable. (Note, any fire sprinkler heads in the vestibules should be freeze proof) . -4. Hallways 1 and 14 shall be equipped with a smoke detection system connected to the systm described in item 1. -- 5. Hallways 1 and 14 shall be equipped with emergency lighting. 6. Hallways 1 and 14 shall be equipped with directional exit signs (as noted on Plans). 7. Exit signs are required in other areas of the building as noted on Plans. 8. Double leaf doors shall not be equipped with any flush or surface mounted dead bolts (only automatic dead bolts) (Sec. 3304 (c) UBC) . 13125 SW Hall Blvd.,P.O.Box 23397,Tigard,Oregon 97223 (503)639-4171 411 • Plan Review 16640 SW 72nd Flight Dynamic, Inc. Page 2 9. Exit doors shall not be equipped with locking devices requiring more than one operation to open (Sec. 3304 (c) UBC) . .1_0. Exit doors shall have sign above "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" when locks require a key to unlock (Sec. 3304 (c) UBC). 11. A minimum 3 foot opening from the machine shop 6 to an exit will be required. t 12. Access by the handicapped into the building is required (Sec. 3,3'64 (A) UBC) . Submit design for accessibility. If you have any question please call 639-4171. Sincerely r - Brad Roast Building Official BR:bs0384W • • • • STASTNYARCHITECTS PROFESSIONAL CORPORATION 614 SOUTHWEST ELEVENTH AVENUE•SUITE 400•PORTLAND,OREGON 97205•503/227-3176 TRANSMITTAL A TO: G,-Cti dP' -VV.( PROJECT C.1 k- -r D ktGr'5„ ibo LO t oe- `v,h•€,M( PROJECT NUMBER (0 t, DISTRIBUTION v 1 0 Nw_ 0P4 A-11. \Alihet-oeiu WE ARE SENDING THE FOLLOWING MATERIALS ❑HEREIN 0 SEPARATE COVER NUMBER DESCRIPTION ACTION OF COPIES OF ITEM(S) DATED REQUESTED 3 _ -$'L2r.,L t` ri,04eal M.Ps��3144 Z•' ._$.(.r_ C?�`- _D IA 3c AZ" _ u.-A,APit _ 12.-2f __ i p __C; � .,, ... 21:11 .�.r� - 12.2•e)Co tP-Sf.Q_ ON %o, 0.00_i NtepA2+tesAgerS..._ .w__ R `l keu) _c(- 11 'tom.. AdZokrt C*411i1.-' 1 .S 45 1 . '_ i o t.l.'1'1_- '[e - REMARKS • � DATE /04 PAGE / OF / 411 411 CITY OF TIGARD BUILDING DEPARTMENT PLAN CHECK NO. : Gz-----1 C--_ PLAN CHECK APPLICATION DATE RECEIVED: f2,--- 3-- FSS P.O. Box 23397, Tigard OR 97223 P/C DEPOSIT PAID: f1(3_3• j This is to. certify that the attached sets of plans have been submitted for plan check pursuant to the Oregon Structural Code and Fire & Life Safety Code, <.S edition PROPERTY OWNER: 1G2 OWNER'S ADDRESS : CONTRACTOR: g /c7( TELEPHONE: 4' :4- 47t JOB ADDRESS: /(C-6'Z90 • 72-- 8/4/1OT NO. & MAP: ;2 ..2-7 - 5/ /6. _ DESCRIPTION OF WORK: r Cvr� / -1 ')'-q4! 7 — Approvals Required SPECIAL NOTES OPlanning Dept . O Reissue OEngineering Dept. O Flood Plain/Sensitive Lands Fire District --9"'--- O Sewer Availabiliy OOther () Other r..J Items Required 5 O List of subcontractorsIV I) \\ Business Tax I ''''':(141-° :::;:::411t)' JCalculations OTruss Details O Parking Plan O Landscape Plan 114;)(1):It\ A/I\ 1 OOther COMMENTS : 0_ ________________ City of Ti and Building Department BY : • STASTNY 1 ARCHITECTS PROFESSIONAL CORPORATION 614 SOUTHWEST ELEVENTH AVENUE•SUITE 400•PORTLAND,OREGON 97205.503/227-3176 TRANSMITTAL TO: .514-0600 R A 1 1 PROJECT -1...14‘1.-C1. 04 tC I-t•( o -T�c4 0 LOCj . Ta PROJECT NUMBER 860 i L/ DISTRIBUTION WE ARE SENDING THE FOLLOWING MATERIALS 0 HEREIN 0 SEPARATE COVER NUMBER DESCRIPTION ACTION OF COPIES OF ITEM(S) DATED REQUESTED +f Mme`PX•: 1,19 10ex 4Titiziottis 3 501`*-42-`... . o6 J if-- 12.22•be, Fad- REMARKS B Z2noyeeitee:44ty? DATE 12 `7-2-.6 C, PAGE t OF 1 ` 410 CITY OF TIGARD MEMORANDUM /5 J TO: Plan Review File FROM: Brad Roast, Assistant Building Offici$1.G -K SUBJECT: "Flight Dynamics, Inc." proposed tenant space improvement DATE: December 19, 1986 In a meeting December 17, 1986 at the TRFPD with the architect, fire department, represent- atives from Flight Dynamics, Inc. the proposed plan layout was discussed to resolve problems in exiting and other miscellaneous items. The results are as follows: 1. Building is fully sprinklered. 2. The lunchroom 25 will have designated area such that the occupant load will not calculate over 49 occupants. RE: Only one exit will be required from space(which will be corridor 27 ) . 3. Corridor 27 will have smoke detection system installed in lieu of one hour construction(per Sec.3305 g) . 4. Corridors 1 and 14 to have smoke detection system in lieu of one hour construction(per Sec. 3305 g) . 5. A wall will be constructed across corridor 1 ahead of electrical room 128 separating corridor 1 from lunchroom 25 6. All corridors in existing office to be one hour rated with labeled firedoors. (condition and extent of fire protection to be field verified) . 7. Existing double doors opening into corridor 101 pose problem of self-closing devices, in lieu of replacement a smoke detection system(connected to all other systems in building) will be acceptable. 8. Swing on existing exit door from hall(between toilet room 129 and computer room 110 and corridor 127 to be reversed. 9. Machine/model shop 6 has no woodworking(all metal) . 10. Existing exhaust hoods in darkroom 20 to be verified explosion proof. 11. Handicap accessibility to be field verified. INSPECTION NOTICE City of Tigard Building Department P.O. Box 23397 29 7 Tigard, Oregon 97223 e�G,� Phone: 639-4175 /27 Type of Inspection /4/9/7 Date Requested /0'1—/�°— Time �.M. P.M. Address / 600 SlseJ /7„2Permit # Owner Lot # Builder 1/4/1"— L — 6igei1 The following Building Code deficiencies are required to be corrected: Presented to t.__Appmxted Inspector _ Disapproved Date / ' CALL FOR REINSPECTION 1-1 YES Ill NO INSPECTION NOTICE City of Tigard Building Department P.O. Box 23397 Tigard, Oregon 97223 Phone: 639-4175 Type of Inspection r,—.N1 S.' Date Requested ` Time A.M. P.M. lit Address / 6 0 O Permit # Owner Lot # Builder The following Building Code deficiencies are required to be corrected: /1\ } r - re , • , Presented to Approved Inspector _ Disapproved Date CALL FOR REINSPECTION I I YES ❑ NO . � ��� ' =�� [ftm � p.4. 1 [ 1- now.Ho. P.O. BOX 127 • TuALAT|w, OREGON 97062 • PHONE 682-2601 FLIGHT DYNAMICS February 12, 1987 16600 SW 72 Tigard, Or 97223 21082— 1 3545 —048-001 Insp. Type : RAS Dear Firestop Company, This is a Fire and Life Safety Plan Review for an automatic fire protection system. This plan review is predicated on the National Fire Protection Association Standard No. 13. Call this office for inspection of installed equipment while the installer is still on the job. Please notify this office 24 hours prior to anticipated completion for field verification of compliance of altered equipment. NFPA 13 Sec 1-11 Approval of submitted plans is not an approval of omissions or oversights by this office or of non—compliance with any applicable regulations of local government. Submitted plans are approved for construction subject to the above noted items being addressed. If we may be of any assistance to you in the future, please feel free to contact us at 649-8577. Sincerely, 1-1/S-6411, k/ Gene Birchill Fire Prevention Bureau PROJECT MANUAL OUTLINE SPECIFICATIONS AND DETAILS FOR FLIGHT DYNAMICS, INC. TENANT IMPROVEMENTS PROJECT NO. 8616 OREGON BUSINESS PARK - BUILDING 10 16600 SW 72ND AVENUE TIGARD, OREGON 97223 DECEMBER 2, 1986 A REVISED: / \ DECEMBER 10, 1986 /L, DECEMBER 22, 1986 STASTNY ARCHITECTS, P. C. 614 S. W. ELEVENTH AVENUE PORTLAND, OREGON 97205AP 4S:"D [(3 DONALD. J. STASTNY. • PORTLA OREGON 1722 �Q. 4 OF ti w OUTLINE SPECIFICATIONS FLIGHT DYNAMICS, INC. #8616 DIVISION 1 - GENERAL REQUIREMENTS A\ 1 . 1 Extent of work shall be as indicated on drawings, specifications and details dated 12-2-86, revised 12-22-86. 1 . 2 The contractor shall make reference to architect' s AIA General Conditions of the Contract for Construction for all new work. 1 . 3 All materials and workmanship shall conform to all applicable current state and local building codes. 1 . 4 Contractor to verify all new work with existing conditions and notify architect of discrepancies prior to start of work. 1 . 5 Contractor shall submit shop drawings of all new work (4 copies minimum) for architects general review prior to construction. Shop drawings of bidder design work shall be for conceptual design review only. 1 . 6 All exterior work, finishes, and colors shall conform to building owners (Pac Trust) building specifications. A1 . 7 Patch and repair walls and ceilings to match existing as required for new work. Paint surfaces at patched and repaired areas to match existing paint type and color . 1 . 8 All existing electrical , nitrogen, vacuum, and other utilities to remain unless otherwise noted. 1 . 9 In optic labs only (rooms 17 through 21 ) , convert all existing air lines to nitrogen from main source. 1 . 10 All new plumbing, mechanical , and electrical work by bidder design. All work by separate permit and to comply to all current applicable codes. 1 . 11 Coordinate all new work with Flight Dynamics, Inc. representative. 1 . 12 General Contractor shall contact owner and coordinate time to review existing building with owner for instructions to patch and repair specific areas throughout building, and provide separate cost estimate prior to start of work in these areas. FLIGHT DYNAMICS, INC. OUTLINE SPECIFICATIONS - 1 - DIVISION 2 - SITEWORK 2. 1 Remove, repair and replace existing asphalt paving as required to construct new exterior concrete loading dock as indicated on drawings. Provide compacted crushed rock over engineered com- pacted fill under loading dock slab and footing. DIVISION 3 - CONCRETE 3. 1 Concrete : Concrete work shall conform to the requirements of Chapter 26 of the Uniform Building Code. Concrete strength for all uses shall be f' c = 3000 psi and shall be verified by stand- ard 28-day cylinder tests. Minimum concrete mix proportions shall be 6 sacks of cement per cubic yard of concrete and 5-1/4 gallons of water per 94 lbs. of cement. An air entraining agent, conforming to the U. B. C. standard NO. 26-9, shall be used with the amount of entrained air being 5% + 1% by volume. 3. 2 Reinforcing Steel : Reinforcing steel shall be in accordance with ASTM A615, Grade 60, for deformed bars and ASTM A185 for smooth welded wire fabric. Reinforcing steel shall be securely tied with #16 double annealed iron wire. Lap all reinforcing bars at splices 36 diameters with a minimum cap of 18" unless otherwise noted. DIVISION 5 - METALS 5. 1 Structural Steel : Structural steel shall be ASTM A36 except tubes shall be ASTM A500 Grade B. Design, fabrication and erec- tion shall be in accordance with the AISC "Specification for the Design, Fabrication and Erection of Structural Steel for Buildings" . Bolts shall conform to the ASTM specification for A- 307 bolts. Welding shall be by AWS certified welders. 5. 2 Steel Studs : Steel studs shall be c-studs with a minimum yield of 33, 000 psi . Studs shall be of the size, gauge and spacing shown on the drawings. Provide bridging in conformance with the manufacturer' s recommendations. /G\ DIVISION 6 - WOOD AND PLASTICS 6. 1 All wood in contact with concrete to be pressure treated. DIVISION 7 - THERMAL AND MOISTURE PROTECTION 7. 1 Insulation: Provide batt insulation as indicated on drawings. Acceptable manufacturers, U. S. Gypsum, Owens/Corning Fiberglas or approved equal . FLIGHT DYNAMICS, INC. OUTLINE SPECIFICATIONS - 2 - 7. 2 Joint Sealers : Tremco THC 901 with Faspak color system to match existing floor finish at horizontal joints and Tremco DyMonic at general vertical interior and exterior joints with backer rod (or approved substitute) . DIVISION 8 - DOORS AND WINDOWS 8. 1 Exterior/ Interior Steel Doors and Frames : Full flush, 18 gauge bonderized skin, factory primed doors. Fabricate frames of mini- mum 16 gauge cold-rolled steel and primed. Acceptable manufac- turers Ceco, Curries, Steelcraft or approved substitute. 8. 2 Interior Wood Doors : Provide flush, solid core wood doors as in- dicated on door type schedule. Provide painted or natural prefinished doors to match existing adjacent conditions. (Painted at offices, natural wood finish at labs and manufacturing) . Acceptable manufacturers Calwood, Eggers or ap- proved substitute. Provide hollow metal frames as specified above to match existing conditions adjacent to new work in office area, or "Timely" prefinished metal frames to match existing in optic lab/manufacturing area. 8. 3 Sectional Overhead Door : Provide manually operated vertical lift type door, 20 gauge galvanized and primed. Verify type and gauge with building owner specifications. match existing manufacturer. Exterior appearance to match existing. 8. 4 Interior Steel Windows : Provide new interior relites as indi- cated on drawings with 1/4" thick float glass. Provide hollow metal frames to match existing conditions. 8. 5 Glass and Glazing : All glazing to conform to specifications set by Chapter 54 or U. B. C. and federal regulations. /28. 6 Finish Hardware : The following is for general bid guidelines and shall be verified on site by hardware supplier to conform to design requirements. All hardware to match existing conditions adjacent to new work unless otherwise noted. Re-use of hardware shall be provided as indicated in the drawings and architect to be notified of any discrepancies or modifications of hardware. Approved substitutes are acceptable of the listed manufacturers (Schlage, Corbin, etc. ) . FLIGHT DYNAMICS, INC. OUTLINE SPECIFICATIONS - 3 - 4 HARDWARE MANUFACTURER FINISH Butts Stanley Satin Stainless Steel Lockset Russwin "Albany" Satin Stainless Steel Latchset Russwin "Albany" Satin Stainless Steel Closer Russwin Silver Aluminum Lacquer Strike Russwin Satin Stainless Stee Flush Bolt Ives Satin Chromium Dustproof Strike Ives Satin Chromium Stop Ives Satin Chromium Threshold Pemko Per Building Standard Set Gasket Pemko ---- Automatic Door Bottom Pemko Satin Stainless Steel GROUP HARDWARE Group 1 : Re-use existing hardware including door stops. Verify re-use of existing 5-3/4" frame on new wall . Group 2: Re-use existing hardware except closer. Remove closer and patch and paint door. Verify re-use of existing 5-3/4" frame on new wall . Quantity Item Number Finish & Group 3: 1-1/2 PR Butts FBB191 4-1/2"x4-1/2" 630 1 Lockset 440 630 1 Closer KPR9113H 600 1 Strike 215L74 630 1 Stop 407-1/2 626 Group 4: 1 -1/2 PR Butts FBB191 4-1/2"x4-1/2" 630 1 Latchset 410 630 1 Closer KPR9113H 600 1 Strike 215L74 630 1 Stop 436 626 1 Gasket S88D17 --- 1 Automatic Door Bottom 412AN 630 /L\ Group 5 : Deleted Group 6 : 3 PR Butts FBB191 4-1/2"x4-1/2" 630 1 Lockset 440 630 1 Strike 215L74 630 1 PR Flushbolts 358-12" 626 1 Dustproof Strike 489 626 1 Strike Plate 487 626 FLIGHT DYNAMICS, INC. OUTLINE SPECIFICATIONS - 4 - Group 7: Hardware by door manufacturer. Verify possible re-use of ex- isting overhead door hardware. Group 8: 1-1/2 PR Butts FBB191 4-1/2"x4-1/2" 630 1 Lockset 440 630 1 Closer KPR9114H 600 1 Strike 217F57 630 1 Threshold 170AS --- 1 Set Gasket 588D17 --- Hardware type and finish to be confirmed with exterior build- ing standards. DIVISION 9 - FINISHES 9. 1 Interior Partitions : Provide and install 5/8" gypsum board over 3-1/2"x25 gauge metal studs at 24" o. c. unless otherwise noted on drawings. Provide gypsum board finish to match existing . 9. 2 Acoustical Ceilings : 24"x48"x3/4" suspended acoustical lay-in panels with flame spread rating of 25. Suspended grid to be cold-rolled steel with main tees 1-1/2" deep with 5/16" exposed flange with rolled cap and integral reversible splice at ends. //�� Provide seismic bracing per U. B. C. standards. /x\ 9. 3 Resilient Flooring : Armstrong "Seagate" (or approved) sheet vinyl with integral coved based at Clean Room #22. Provide com- mercial vinyl composition tile or carpet bid alternate at Hall #1 and Lunch Room #25 with rubber base. All colors to be selected and approved by Architect. Patch stained vinyl composition tile to match existing as indicated on drawings. 9. 4 Carpeting : Provide allowance of $11 . 00 per square yard for car- pet and pad installation. Color and type to be approved by Architect. 9. 5 Painting : Provide one coat gypsum board sealer/primer with one finish coat satin alkyd enamel at all lab, manufacturing, and lunch room areas. Provide approved primer over concrete and con- crete block walls. Provide two finish coats of interior satin latex at office walls. Verify to match existing paint type and colors unless otherwise directed by Architect or Owner. DIVISION 11 - EQUIPMENT 11 . 1 Load Leveler Seal : Provide and install continuous preformed weather seal @ 1/4" max. height at perimeter of existing loading dock interior load leveler for weathertight seal . Verify type and size with Architect for approval . FLIGHT DYNAMICS, INC. OUTLINE SPECIFICATIONS - 5 - 11 . 2 Emergency Shower : "Lab Safety Supply" #G1373 (Horizontal Pipe Supply) or #G1372 (Vertical Pipe Supply) . Owner supplied, Con- tractor Installed. DIVISION 12 - FURNISHINGS 12. 1 Laboratory Casework and Fixtures : Modify existing lab counter with fume hood in darkroom #20 to provide for owner furnished processing sink as indicated on drawings. Contact Al Schultz at VWR to modify existing lab counter and to provide new support for existing fume hood. Al2. 2 Kitchen Cabinets : Remove, relocate, and install existing cabinets as indicated on drawings. Patch and repair all existing walls as required to match existing. DIVISION 15 - MECHANICAL 4\ 15. 1 All mechanical work by bidder design. Coordinate all new work with existing conditions . At machine shop area, provide suspended gas-fired unit heaters at 70° inside. Verify possible re-use of existing unit heaters. 15. 2 All plumbing work by bidder design. Coordinate all new work with existing conditions. All water , waste, and vent piping to comply with applicable plumbing codes. Re-route and connect all exist- ing pipes as required to provide new wall penetrations as indi - cated on drawings. DIVISION 16 - ELECTRICAL 16. 1 All electrical work by bidder design. Coordinate all new work with existing conditions. Re-route and connect all existing services as required to provide new wall penetrations as indicated. 16. 2 Service : Contractor to review and verify existing electrical service to be adequate and to code for all new work proposed. Service shall meet U. L. requirements with U. L. label . 16. 3 Lighting : Provide new and revised lighting as indicated on reflected ceiling plans. Offices : Revise, modify, and add lighting as indicated. Work/Copy Room: Add 2' x4' recessed fluorescent light fixtures to match existing and to provide approximate 80 footcandles, or per code requirements. Hall #1/Lunch Room #25: Provide and install new recessed fluorescent light fixtures to match existing as described, reflected ceiling plans, at approximate 70FC. FLIGHT DYNAMICS, INC. OUTLINE SPECIFICATIONS - 6 - Manufacturing/Machine Model Shop: Provide and install chain-hung fluorescent light fixtures as described on drawings, reflected ceiling plans. (Columbia, Keystone or approved) . Hall #27 : Provide and install surface mounted fluorescent light fixtures for hallway lighting illumination only. Alternate Lighting Bid : See sheet A2. 5. Warehouse: Relocate existing chain-hung light fixtures as indi - cated on reflected ceiling plans. A16. 4 Provide and install smoke detectors in Hall #1 , Hall #27, and, Hall #123, per U. B. C. 3305 ( g. ) exception 5 and connected to an approved fire alarm system installed in accordance with NFPA No. 72-A, 1979 edition. Contractor to verify with local Fire Marshal for quantity and location required. 16. 5 Provide and locate new exit signs per Fire Marshal requirements. /2-\ 16. 6 Heating : Provide suspended "Co-Ray-Vac" radiant heaters per con- tractor design. FLIGHT DYNAMICS, INC. OUTLINE SPECIFICATIONS - 7 - DETAIL INDEX A. SITE DETAILS A-1 NEW EXTERIOR LOADING DOCK ELEVATIONS A-2 NEW EXTERIOR LOADING DOCK SECITON G. DOOR AND WINDOW DETAILS G-1 PLAN AT LOADING DOCK DOORS G-2 SECTION AT LOADING DOCK DOORS G-3 SECTION AT LOADING DOCK DOOR STRUCTURAL SUPPORT G-4 TYPICAL SECTIONS AT INTERIOR DOORS AND RELITES G-5 DOOR TYPE SCHEDULE G-6 DOOR TYPE SCHEDULE G-7 RELITE SCHEDULE K. INTERIOR WALL DETAILS K-1 TYPICAL SECTIONS AT INTERIOR WALL CONDITIONS K-2 SECTIONS AT NEW WALL AND EXISTING LAB COUNTER K-3 TYPICAL LOW WALL STRUCTURAL WALL FRAMING K-4 TYPICAL HIGH WALL STRUCTURAL WALL FRAMING FLIGHT DYNAMICS, INC. OUTLINE SPECIFICATIONS - 8 - ak, ob, 1 ® ____„..____ he.... '7 S CO, \\ _ IN, :.•%,..J ..i .-1, a.2, i \--\\rnAi-Iv W,,,, / \\ T E,1(I$r, \ 0 ' .-- ly 0 �ki5' S7,4Jtp / _ 0 /4 /CD) ,..,,t2b, 7.4°,‘,11,k'- _ / „. 1ZF. 1• S.F.r.>*. a—pt.{ NEW LOADING DOCK EAST ELEV. 0 " '11 it 1 , i 02: 5-,04..JN I II III III eu,5 7 p- L. 1 U giFir-otoVS S ;4. ZS 1 iii Ptokt2-7l,o. Ck S; I II Hp.r-oGT2,4:b,," 74 7-- _--1 I II \.1=g2.7P,�r 11 III II III L ______�� iii I i..r - 126'.CXA.a /XV T .,ara • �,HCcv oGk O NEW LOADING DOCK NORTH ELEV. /G''= ,1-000 date STASTNY ARCHITECTS PROFESSIONAL CORPORATION drawn bFLIGHT DYNAMICS, INC. 814 SOUTHWEST ELEVENTH AVENUE•SUITE 400•PORTLAND.OREGON 8'!205•503/22'I-318 lz.:?%sic OFFICE/WAREHOUSE REMODEL A- 1 prt ct no FLIGHT DYNAMICS, INC. PORTLAND. OREGON WILLAMETTE PRINT&BLUEPRINT Po) `• 6.1.0." ,-c217.. 1641,- Ii—T EX 17, II II I I - NE-1 H r-1, 1D12• ? FP.,o. i.J/ I I O, -1. 02, ar;1'01" II II II II II II II NE1J CoNG, L.044).% 11--1 0.G4. I I 5" S 8 ori C 3 2 4211 o.C, 0 4_ c% S 11 . .G x 2'-oil a 2° 0,C, :. 1' 2oUT' II Ihb Ho_E, -7Tf? c PEa. ME as 2'-o0 I I 10 ��" 4. 3c —1p I i i/4," !'-O" _ 12" 0,c. ( I � 1 \ ‘5...o B fi% le ,► '�, `y`k�a � 'A- r�._ ,h, = �` ,, i+— ,,i.� ,, --jJ =1111(- -=---------.1 i';--g Y C.,-2. UI 1 _ • III .I,;' , U (o" MIN, Cl/JJ SHrAD 7 ' ).-- 3 CuorfrSC) =1 L.L. v g d (o° COt ., IJAL-L ....1/ .4 69 +> 4 � C I Z o,G, u ,T• ; _ a 4 I o,G, no21Z, 1p D 4. of 44-JAL-L.44L-L. _) S LEt-i-OV E, Ex 1 S7 (v.-co o,c, I__ __ __ 111111l(lID_111.1 .IIp n '''i tII 4 411 I I ASP, i a,1., -(o i N (I) P .,• . .....6... 1�lATG H Sc , s r •— • _ (2)4. 4 e>4."4 o' I _ZI 0 SECTION AT NEW LOADING DOCK •-• /.4.11., 11..01( 11-p1( date 2.. 4 n STASTNYARCHI'1'ICTS PROFESSIONAL CORPORATION 814 SOUTHWEST ELEVENTH AVENUE•SUITE 400•PORTLAND,OREGON 9.1205.50••U22,3118 fir{i1 i DYNAMICS INC. drawn b fit#/sac. OFFICE/WAREHOUSE REMODEL A-2 project no FLIGHT DYNAMICS, INC. PORTLAND. OREGON WILLAMETTE PRINT&BLUEPRINT , e 043411;1 \ rOC...Cc e . 5;t.,L_ 4r, 5 .+v� ° 2411 0 c, N Com) t2' ;1 tea:- ;J ;.xIST CoNG �a�L /" h 1-'‘.-10,H, Q Q� ,...Y 1� _ I -� Ve,f1",GAL., LI I �iUt2ro-C�E 4PP-40 --1 I �' c 1/41 0 .4.!•,=C , 4 O2 C' 1 4'-O" O G, c:c., AcQ. *e' 2 v/ 1 P"1' TO NeTAt- ...,--. = I?sc 7-',E1'1OA_Ot~5, ,-;" _ iH.i"�"f..� I T.S. r0., K�j l� Y Tri/ n , _ /, , f iL I tt v-3 r r 1� -4 ,� _ o �-ID �® � � p> 42 3 21 F`r��01,-1,--� � _,---71-:1-----;'--. x G-Z ---1/4\ gi 1 pc,.'ZT i 71 7 0,4-i _ -1 1 Val. 7 a,-+, 0r2ia?�«.J4�E. 111drUl I(-1 L— 1 I coHr. sayv.L.ar-I 7 ---ro G� LJ� CoE a,NGto2 6,L/2..e;,-o ' o,G, Mir+, - Ty-h, 0 PLAN AT NEW EXT LOADING DOCK DRS , 11211 :.,. 11.4":)11 1W-5 STASTNY ARCHITECTS PROFESSIONAL CORPORATION FLIGHT DYNAMICS, INC. 814 SOUTHWEST ELEVENTH AVENUE•SUITE 400•PORTLAND.OREGON 97205•003/227-3178 c-A 2.-JG- 1 P/ K. ' OFFICE/WAREHOUSE REMODEL prQ r-eot no FLIGHT DYNAMICS, INC. PORTLAND OREGON Ni1(a; WILLAMETTE PRINT&BLUEPRINT e Y ---A\------ HIHo GH, 02. oHL`r- _43- -� --- I ,.._,L--\___A----- e- 4- I I 1-4-.1,..JGsS -�2�HSoM I I W pv,,-., 11-- H,M 4:t7.a. c' qI =} z I I . IQ ' , , Irr ` a - II I I .z , N5.. .) HIM, 02, ' "4Q,a,fMe: l t°,4,►c,- "'Rtcer SPSC5, I I1 D YP A.74.-. �xT, =ir+ISH�. II I I X r til I MEQ., Co�+L, � o miciH� co . I I I I S GT I O."'{ A- 2 I II L . , D 0 U v cpSECTION AT NEW EXT. LOAD. DOCK DRS. 1%211 .;1 -011 date draw�b• E+6 STASTNY ARCHITECTS PROFESSIONAL CORPORATION 8SOUTHWEST ELEVENTH AVENUE•SU=400•PORTLANDOREGON 89203.503/227-3178 FLIGHT LYt vS' V• ,,?,(0 . , OFFICE/WAREHOUSE REMODEL G -2 project(no FLIGHT DYNAMICS, INC. PORTLAND. OREGON WILLAMETTE PRINT&BLUEPRINT , ----ZPI--- , O1)"2.24-rte D2. ' �2.c.^--'E Ikj / ; if- to \ I I, ST.-1..J 6'' XT'' k 1 41 R., c-7-1.- 1..J/ 1//2.0 el, LJP, &e h.riG n C I0 11-.1 7.0 :><it-.7. Colts, HBa.a, I I 4, 0 C I, I, 1; f. „Z.Y,v 4 L-J_ \Ir k.....,--- /I(�II V \, ,„ -. 4 NEL- COG, 10.1.? N4, K 1 ' �K1 ST, c rl...f L I:.MES ozEt7.1 \\� 1...J Cc)1., TO L _____cgi ._.\ 0 SECTION AT NEW STL. DOOR SUPPORT I /2.. = 1l f`- /7--r-P, e TUBE -, P a TO l•— ———— - - - lir,'' V \F:. (2) SIO.% fri ae.= •. ._ tl �. NJ.� G"{;o'' 1/�T,S , Coy , ® , _ T�6:. scIST, . /i 6" V �AHb�E T YP L3 HE�n CA►8c7vG), I.-JaL.. j 1 e Tp g? ✓,..I'C=14 '5/ ,° '1',, „srT, 0 .. ... . 0 PLAN AT NEW STL. DOOR SUPPORT 1 l/Lll . Il'C ll di t 2-AG STASTNY ARCHITTECTS PROF.AL CORPORAITON 614 SOUTHWEST ELEVENTH AVENUE.SUITE 400•PORTLAND.OREGON 97205.503/227-3176 FLIGHT DYNAMICS, INC.drawn by ✓ G-3 Pl� K ' OFFICE/WAREHOUSE REMODEL pr Esc r FLIGHT DYNAMICS, INC. PORTLAND, OREGON I WILLAMETTE PRINT&BLUEPRINT .... R ecJQ , 111111 aE c2. F L.fZ, P i,...a.r-i5 Ma tH !ST +-fZ�t�will _ NLli IN A...j, 2MfS, N=:,.,J pa P52 =2,, 7.71=E. Hi9�La Ire I 0 NEW INTERIOR DOOR HEAD (JAMB SIM.) 3,I : I,_o" N C 1.J O'Z !g T,, P0.L27•1"fl O S • PF.2. r=6,1"L, L.43..lycj '2— `1 - i 1/411 C.:, r •iT� W/ MT'L,, SraP • V EI: NEW INTERIOR TYPICAL RELITE FRAME 3r= Ii_po d e aTJi. STASTNY ARCHITECTS G. Z' PROFESSIONAL CORPORATION xT1 DY /'rr C J' INC. 8149OUTIWSjFEVEN1HAVENTE•S7ITE400•PORTLAND,ORSUONa203.503229318draw5K OFFICE/WAREHOUSE REMODEL G-4 project no FLIGHT DYNAMICS, INC. PORTLAND, �I� � OREGON. WILLAMETTE PRINT&BLUEPRINT • DOOR TYPE SCHEDULE T I OY I Od aEu75 VOI D AIL SOLID CORE WOOD ;RELOCATED EXISTING PRI, ' DOUBLE, • FLUSH W/ RELITE HO OW METAL 0 '1,1-0°x 1'-0x I / II \/ .1 0(2.) 6," I-C1 x B. • Y R6.IT°: DOUBLE SOLID CORE. SOLID CORE DOUBLE SOLID CORE WOOD FLUSH W/ RELITES WOOD FLUSH WOOD FLUSH (1-..; 2- 0,-0" x11-di)4 i /4-1Iji (2) '-O' „ co o" K t/4)1 HSE DETAIL 1/0-4 0921-d1,4-11-- 1)(1 /4-" FOR TYPICAL FRAME DETAILS date 2. bG STASTNY ARCHITECTS PROFESSIONAL CORPORATION d f a y 614 900THWESC ELEVENTH AV ENRE S[RTE 400•PORTLAND,OREGON 97205•505/227-3176 FLIGHT DYNAMICS, INC • _� OfFICE/WART7OUSE REMODEL prgeti FLIGHT DYNAMICS, INC. PORTLAND: .OREGON. WILLAMETTE PRINT&BLUEPRINT F-EV IS D 2•2Z-�C,s PRIMED HOLLOW METAL OVERHEAD STEEL W/ GLASS TRANSOM (G) t'-C74 7‘ 1 >e I -gir (H) X dte „. p STASTNY ARCHITECTS PROFESSIONAL CORPORATION d a W rl b 814 SOUTHWEST ELEVENTH AVENUE•SUTTE 400•PORTLAND,OREGON 89205•503/22,3178 FLIGHT 1 i 1 t L liYli i✓ INC. v OrFrFlCE/WAREHOUSE REMODEL _6 project no FLIGHT DYNAMICS, INC. PORTLAND. OREGON. WILLAMETTE PRINT&BLUEPRINT RELITE SCHEDULE 411, 411 41111 IN z 41) • • (C) , 411) CDD ,20 � �1—oi SEE DETAIL 2/G-4 FOR TYPICAL FRAME DETAILS date_ STASTNY ARCHITjCTS PROFF34IONAL CORPORATION / �� drawn by914 SOUTHWEST ELEVENTH AVENUE•SUITE 400•PORTLAND.OREGON 9'1205.503/221-3179 FLIGHT DYNAMICS, INC. OFFICE/WAREHOUSE REMODEL G' project no FLIGHT DYNAMICS, INC. PORTLAND. OREGON WILLAMETTE PRINT&BLUEPRINT M�,I.J INT��o12 I��.n.T'ioN j / To I b H f 11 F,aGS C Cf L .J V/ PH w -1... 1 ex 1' . L,J4,..- NEW INT. PART. AT EXIST. CORNER !' c i:, „ 1 „ 4 1 1 ZAHGIC.� di' Q OH $ q I h I ;_ , �L.4,.NS >k tr I I stE hi TCr1 �x'ter . .. m :.• Y NE.-14..J =al-. Srua 'o 1 Ttri Cu1Sr =Z44-1if-'l4 Z el PLAN AT NEW FIN. OPEN. AT EXIST. WALL date 12. 2-so STASTNY ARCHITECTS PROFESSIONAL CORPORATION FLIGHT DYNAMICS, INC. brawn by 614 SOOTHWPBr ELEVENTH AVENUE•SUITE 400•PORTLAND.OREGON 89205.503/222-3198 FLIGHT 2.J /STK 0J'NCE/WAREHOUSE REMODEL K- 1 pr6ct.Co• FLIGHT DYNAMICS, INC. PORTLAND, OREGON WILLAMETTE PRINT&BLUEPRINT f fr I`Ne,LJ IN792i02. .ZTi'r•o"t, TAMC{-10. TOP 72.6.c.c. 111/ jcr..11", TO uNo5r2.4v 1 U Jr1E.Mcs.„E. Cirj1-, ../A`ve. c.A.?S TYp s C4.4=, \,A-A!'t • 1.-11-e. • _sz CONT'I NfTL, i'LP!�f . 4-- • I •V .6.L-I4eM 6.1 4•4.1.0 5U2PSE l.. S /� Fuc IST, La-45 CfJUN ✓Q l NEW WALL & EXIST. LAB COUNTER C) SECT. • AT u n y - Si' a amu H i2 e_.,,,,, L....... / 1 l 1 1 \ P•�;i AC 1 NcJ.J MTL STS 1 .. c cDic ExESTI Com• 4-4 MIL, SUO I . • (,7 PLL E-%..12 P1..44"..i 2 PLAN AT NEW WALL & EXIST. LAB COUNTER � n_iI_pu date STASTNY ARCHITECTS PROFESSIONAL CORPORATION /,,.2- FLIGHT DYNAMICS, INC. drawn by e14 SOUTHWEST ELEVENTH AVENUE•SUITE aoo•PORTT.AND,OREGON 97205•503/227 3176 1GK OFFICE/WAREHOUSE REMODEL K-2 Prer , FLIGHT DYNAMICS, INC. PORTLAND. OREGON WILLAMETTE PRINT&BLUEPRINT GOMr 72GC.K 80TTUrt =04 245 S �/2'' Y y5 G4 Pet-, 3/2"x 25 erk c-37%.10S SDE A �YPIG,aL F•R�I`r1e= D HINL7 pIGJ.r co 1I/1„11_ U U MIN, Go*N EGTIOH- 'I 1'f? i � 3 2 I x 2 6 Cab, S?U D C' �j',pu O.G. IN''IAX, I 22 GA. TRAG K ;opt ,50 7-7,C) - TYR ?✓�, S1o5; U N CT145 r1:.J S N O'-�D, • -v 1/ • x 2tom. S-u ca c 2,411L.4/ 3/a,, rL4mc=.5 451' C,6LOLJ v LEX i 7"1- 4.67- Y4.6 4'-C7M MIN, / 1-17/ NOS Przr. e k.I G K E.2 or= ,Q W/ C z) S' UCAS SICK __ E.rlih6, I�IGKE2 MA1' F c=t-"IITitt= C 1 TYP. LOW WALL FRAMING SECTION c 1 , -cII date drawn. 814 SOUTHWEST ELEr_24111 AVENUE•SUITE 400•STASTNYARCHITECTTS PRND OREGON OFESSIONALCORPORATION FLIGHT DYNAMICS, INC. 5s o OFFICE/WAREHOUSE REMODEL K-3 pr iLs tImo " FLIGHT DYNAMICS, INC. PORTLAND: OREGON � , WILLAMETTE PRINT&BLUEPRINT r I 8 i \ G,'v 2P 6Pc atm/ , 1 To?, ec rroM cs. 11 I , ries. , 6"x Zo Cva a oza- 6„,a4...4... Si-1.405 12SL i re., I ' I \ fit„ 6," 12_Ja STups F.4.-, S(0S ST72i..1c-ur2.a > A T'f4.I caa., F e ,;:)=.6N I N A >3 TYPICAL, H 12 1/4" z r •c,i, f 721'. i -ON �I 1 --N---ExiSr, C.L. 6c...A1*-1 4. 13'/2 x 21"; &A. nom► J= �iAMIN6 l= * 'r cI, PKdvla E, (Z 1/ 0 5 Ga2�J.JS, MIH, PS,Q CAHN'=Cl-IOr - GI' x 20 CSA S-1..40, :•.1/ 1.5/6" ,o,,H(PE ' 4'-O° a,C. P Q'-'a=E ® (2) STUDS cA, SICDI<, OP pcxOtZ P20 ' i-r02IZ 8rIHF, II 2� II e 5'-0" o,C, r-1 .,( F 5/�" -rP .. 4.(=E, -C: I= Go 'e 22 (s41... S UC 1 'T'-O° 0,G, 1 I' lac11.4JES-IS Ful_, . t- STuaS t ' , 145 II usllJGITYErz 1:Dr21 -d6"-I Fa`-TNE12 e 31-OII otG, MIN, C1TYP. HIGH WALL FRAMING SECTION • -?j/4I1 . 1i-oil date 6 STASTNY ARCHITECTS PROFESSIONAL CORPORATION I2 z b FLIGHT DYNAMICSINC. drawn 634 90UTfiWL41'ELEVENTH AVENUE•SUITE 400•PORTLAND,OREGON 97205•5052227-3176 ' `�Epi OFFICE/WAREHOUSE REMODEL K-4 (PrOeIroFLIGHT DYNAMICS, INC. PORTLANDOREGON WILLLAAMETTE PRINT&BLUEPRINT