PFI2018-00212 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
COMMUNITY DEVELOPMENT Permit#: PF12018-00212
13125 SW SEG3
Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 2018
Parcel: EG3880
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: PGE
Project Description: SEG 3880/3881 /3882. Install circuitry for 17-60 LED Yarmouth. PGE Job M2509681.
Owner: FEES
Description Date Amount
PHONE:
Contractor:
NORTHWEST EARTHMOVERS INC
PO BOX 1609
SHERWOOD, OR 97140
PHONE: 503-625-3100
FAX: 503-625-3108
Applicant:
JOSE GRAJEDA
10800 SW AVERY STREET
TUALATIN, OR 97062
PHONE: 503-672-5602
Total $0.00
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant
Signature: See application
Issued By:
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12018-00212
Type: Condition Name: Status: Severity:
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of
any agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02 -WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited
and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up
and suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be
reinstalled or replaced; with like kind of material. Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition, American Traffic Safety Services
Association [ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work
area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be
effectively maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time, without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and
area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire& Rescue) and to 503-962-8140(Tri-Met)
and 503-431-2345(Tigard School District) and other service providers impacted by such closure.
PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7.00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the
City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m. to 9.00 a.m. unless authorized
by the City Engineer.
PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987.
If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole
before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at
the applicant's expense. Changes must be approved by the City in advance of work. Applicant shall coordinate the work
with affected utility agencies.
PFI_Utilities 14-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by
the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name> at<Insert
Phone#>, to establish a preconstruction meeting.
PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged
inspection, and after completing work covered by the permit.
PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI Utilities 19-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, anc survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI Utilities 20-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing, the names and 24 hour emergency telephone number of two(2)persons who have
authority to resolve problems, take corrective action and, in general, will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI—Utilities 21 -OTHER Applied Notice
RECEIVED
City of Tigard AUG 13 2018
a PUBLIC WORKS —ENGINEERING CITY OF TIGARD
PLAN NING/ENGIN EERING
Public FacilityImprovement (PFI Permit
TYPE OF WORK
DESCRIPTION OF WORK(in the right-of-way)
TYPE 1–Franchise Utility Work
Check one: V Utilities ❑Sidewalk/driveway approach ❑ Street improvements performed by NWN, PGE
Detailed description: Install Circuitry for 17-60 LED Yarmouth and/or utility agency.
❑ TYPE 2—Sidewalk/Driveway/Sewer
PGE Job M2509681 Work performed for the purpose of:
• Sidewalk installation or repair.
• Driveway approach installation
Property address/location(s): and/or repair
SW ROY ROGERS RD & SW BULL MOUNTAIN RD Tigard, OR 97224 • Sanitary sewer lateral installation
00j 8 Z 3 Ot3 n and/or main line tap
Applicant: Portland General Electric El TYPE 3—Full scale Development
PP Work performed with Land use
Address: 10800 SW Avery St. approval which includes any of
City/state: Tualatin, OR Zip: 97062 the following:
Phone: Email: preregcoord@pgn.com • Subdivisions or Partitions
Contact name: Jose Grajeda Phone: 503-672-5602 • Street widening
• Mainline installation for Sanitary
Northwest Earhmovers sewer, Storm sewer, Tigard water
Contractor: and/or Tigard Water Seance Area
CCB#: 62761 Expiration:
Address: 13600 SW Calbreath Dr SUBMIT COMPLETEDAPPLICATIONTO:
City/state: Sherwood, OR Zip: 97140 City of Tigard
503-572-3863 mmadison@nwearthmovers.com Planning/Engineering
Phone: Email: @ 13125 SW Hall Blvd.
Contact name: Mike Madison Phone: 503-572-3863 Tigard,OR 97223
Applications for"minor work in right-of-way"
only may be emailed to:
Engineer: NSA romMermits_.tiga�rd_or.gov
Address: 'in
City/state: Zip:
Phone: Email: Case No.: ZO ff-iO212
Contact name: Application submittal fee(.007%of
Engineer's Estimate) $
Estimated value of work is required(if over$5,000):$ 91,778.23 Additional fees: $
(within the public right-of-way) Application accepted:
12
Is work related to a LAND-USE DECISION? ❑ Yes No By: Date:
If so,please specify (MLP,SDR,SUB, etc.) case #: Application reviewed:
By: hA• '---) Date•
Is work related to a BUILDING PERMIT? ❑ Yes No Applicant notified:
If so,please specify(BUILDING PERMIT)case#: By: Date:
I:\ENG\PermitApplications\pfi_application Rev.10/16/2017
City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 1 of4
APPLICANTS
NOTE: Person specified as "Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if
required by the city pursuant to TMC 15.041.140.
* With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different
people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the
owner. The owner(s)must sign this application in the space provided or submit a written authorization with this application. Franchised
Utilities are not required to obtain the owners signature on the application
BY SIGNING BELOW,THE APPLICANT(S) SHALL CERTIFY THAT:
• The above request does not violate any:recorded deed restrictions that may be attached to or imposed upon the subject
12rol2em.
• If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
• All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and
the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such
statements are false.
• The applicant has read the entire contents of the application,including the policies and criteria,and understands the
requirements for approving or denying the application.
A- Aroun Xaybanha 08/10/2018
Applicant/AutlYbrized Agent's signature Print name Date
SIGNATURES of each owner of the subject property, if required.
Owner's signature Print name Date
Owner's signature Print name Date
Owner's signature Print name Date
PUBLIC FACILITY IMPROVEMENT PERMIT
City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov 503-718-2421 • Page 2 of4
DEVELOPMENT ENGINEERING FEES FOR STAFFUSE' ONLY
Public Facility Improvement(PFI)Permit:
DETAILED SUBMITTAL
REQUIREMENTS
APPLICATION FEE
Part 1: Required submittal fee$300.00 (minimum) FRANCHISE UTILITY AND SIDEWALK/
DRIVEWAY AND UTILITY
PERMIT FEE CONNECTIONS,ETC.
Part 2: All non-water system improvements (work in the right of way)
Engineer's estimate X 5%(less$300.00 minimum
submittal fee) Sketch
Engineer's estimate X 2%Plan Review (including information below)
❑ Dimensions
WATER SYSTEM FEE ❑ Street Name
Part 3: All public water system improvements ❑ Site Address
Engineer's estimate X 12%
FULL SCALE DEVELOPMENT
PFI Permit Fee Exemptions: (Subdivisions/Partitions and Street Improvements)
There will be no permit fee charged,or assurance required
for the following types of work: Design Plans
• Sidewalk repair(less than 20 lineal feet) (G sets,24x3G or 22x34)
• Relocate or replace mailbox ❑ Cover—Site,'Vicinity,Abbreviation,Legend
• Ditch cleaning that does not involve regrading. ❑ General Notes(City,Water,Sewer,etc.)
• Weep hole repair ❑ Street(Plan,Profile)
• Curb repair or replacement(less than 20 lineal feet) ❑ Water,Storm and Sanitary(Plan Profile)
• Lawn sprinkler system installation or repair ❑ Water Quality Facilities
• Street tree pruning or planting ❑ Grading
• Planter strip landscape maintenance ❑ Landscaping/Tree Plan
• Test wells ❑ Composite Utility Plan(Electrical,Phone,Gas,
Storm,Sanitary,Water,Signage,Street Lights,etc)
❑ Details
Note: A cash/bond assurance maybe ❑ Traffic Sight Distance
required per TMC 15.04.140. ❑ Signing and Striping
(customer deposit) ❑ Street Light Plan and Photometric
❑ Engineers seal/signature
❑ Sheet label(pro)ect land use name,revision and
plan log block,dates and sheet numbers.)
Additional Submittals
(per Land Use conditions)
❑ Traffic Report
❑ Storm water Drainage Calculations
❑ Geotechnical Report
❑ Preliminary Access Report(Sight Distance)
❑ Proposed Plat
❑ Pathway Design(if applicable)
❑ Water Department Approval
❑ Engineers Construction Estimate
PUBLIC FACILITY IMPROVEMENT PERMIT
City ofTigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 3 of4
SAMPLE SKETCH:
Edge of Pavement
Ditch --imp`
Streetlight
� I ,
I T r o 15 oscry ja LTi n e
Existing House
r� I Existing I
>i Driveway .
a i
CI R I � �•
I I .I
I �I
4!I R
O
IU I I � "
IU
�s
L .
oI I
Existing Shop
Powerpole I I •
o , 2 i
-------
property Lin,-e ------_---
I I
I Fire Hydrant(FH)
I
I � �
Scale: 1"=30'
I � �
I �
I I .
I i !
MINIMUM SKETCH REQUIREMENTS (Put"N/A" if Not Applicable):
North arrow Property lines & dimension Slope of property
Street &street name(s) Existing building, structures Utility&street light poles
Proposed work Existing curb or edge Trees
Existing S/W or of pavement Existing utility locations
D/W apron (sewer,water,storm)
PUBLIC FACILITY IMPROVEMENT PERMIT
City ofTigard • 13125 SSI Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 4 of4
91 77> I I' SW BOTANY BAY LANE
I � 78
" I 79p
Do.'
Dop '
K4D
X�1r1I ,I 11 !! ' � '� L -�•__'____� I ' - -y -
// 7 1---- '
II ro PD L .f
a ---- i/ - `' 195 `T1}919
If
i� -ta G.
-s, �a-es , 6 i
2tlN k` r Imo=- i 175
f a 89y ; gqm
r
""!i 17
TRACT
PJ ti '( PD hP7�t I TRACT W 1 _-_ Is. I 176
z Ju
I r
VT G6
TRACT Y
II SW ROCKHAMPTON IAfiE I I I
'i TRACT. 1 I ,�,�y I;� I'R ;
231 r SW ADELAIDE LANE
(a sip '�Rh 1 f 177
12A2h 24 �240M r23�A 238 :237: 276 x235. 234 233 1232 i.lr l 1 BB
VS VS y.� & ; �r_e fsi Is,YOI
J.l
JbL •77 ds ' nVS .1 TRACTV las .i&L 183 fez 179 r
` -JbL HS Jbl /:,/t / I \\ 'tC.�x Alti'° •161e 180 1 dB
A 25 i ;111JJJ 1a-v5 Des sLrc ,a-es �a-es ices- be V 1 F5l iia
,
131' 1
I-21- -- -'T
-�-- `-�--\---e
VPD-2Z '�0' •� ��- _- '10-'- - -. - 77I Vi-Y12
2]B -__1_•- -_• ____- 7N
_
II17
K-221,20•r 20'1 067 \K q
SW BULL MOUNTAIN ROAD sK-213 rPL-214 20,
y n-745 a �' `,� 20-1 -- --.._-n 747
- 4 j
1 {K-218 K-219 'I \7p1-751
(C.R.NO.2621 n-z61t I 1/ r
Nr
I 1 PL-759 �K-758 PL-711 F I�j n-2.1 I I{( II
20'\ 1 95' .- -! TO' A 111' 20 \ -` 1 -241 l,__- IL-756 PL-755 PL-251 117'II It 757 t
_ -_ ---__-139--_- - - A \
1� _-_--. 6- F K-Ta? 133 - -_ 70
rt-233 __-_ N-732 -_��r , \ _��- -_.. -- _ -x_________ _ _^ '1?_______ 11
Vf 735 Vr_771 �` \ ' �. -�
N-230 N-7� K-778 yr-TT) -r--_ �E 00, i Vr-225 -.____--.
VT 250 1�7 �____
Vi 260 'T_226 -►r
Sn 8 STUB
Pt-253
LIGHTING LEGEND 2 PIECE FIBERGLASS COMPOSITE POLE
CONSTRUCTION NOTES: SLCST (COMPOSITE) MTII a wuLT wiisaroe Trm
LLRaLEss oTIRR1NSE SIEOFIED) AAA.I �� I .REraereowcourpoo AI
INSTALL FID AL-TX ST Li CIRCUIT IN 43-SCH40 NC T-.•r T o--1"'• 1 V
1.CUSTOMER TO FROVR)E ALL TRENCIMG.BACKFRLMG.CONDUIT.Ela0W5.JI..CTIOR
CONDUIT.PROVIDED a INSTALLED BY CUSTOMER BOXES,vAlAT3 AND TADS,DONT MSE TRENCH YIITN OAS TRENCH'a.
•rs.P "'
N RICHES DEEP ANO 30 ARCHES VIDE.MEASURED FROM MALT
INSTALL"M C1.1-M Si LT CMCUn M N•'SCNM IVC
CONDW.PROVIDED 6 INSTALLED BY CUSTOAER 2 ILM[STNNBY CREW IS REWNtEO FOR OPENNf KL ENERG¢ED POE VA11LT5 THINK
.MICTION BO%E5,ARD EOtiMENTFACIlr1E5.NCLLDNG COIIECl1ON OR N41ALLA/10N W =_ E a CONTACT SERVICE COORDINATOR /rENTro L GILL all BEFORE YOU DIG
Q CVSiOMFR INSTALLED IIlO ar Lr SECONDARY VAIIIi OF CONDUTS AND PULL STANDBY
SERVICE caoaDRIArDN AT SO15x36T0O �- c-. •.,� SAFETY
TO SCNEDIILE A PGE STANDBY CREW- FO•-NKv Arm�M+DuI'N}HrnON n�M N Uw REQUIRES YOU i0 FOLLOW ICES.DOTTED ,
F' s.ceaii K vti Nor+nT.ut... 111E OREGON Unlm'NOTIFICATION CENTER. ,
INSTALL IPV LEDLEOTFR BUCR y r p p�r�f writ TRFwcv n mm uraHUFo N
].ALL POE COKKICTORS TO BE NSTALLEO IN OINY.SCtEDUIE An.ELECIRICAt M F.MMa� '1' f iB�J S I O NIIES Mf SA FORn/N OAR 95T-OOL0010
ON 11"1 FIBERGLASS POLE(75'MTG NGTI WRN IRADE WRM NYLON RAI STRINGS CONDUITS
SR LBS.1EST SERVICE[aOROiYlE1f 9y2-Op1-0090 1'011 ANY pBTAM COBS OF
6'ANS'ARM CONNECT 710 VOLTS PGE TO OET VERnE TIE S�AND NUMBER OF CONOIATS RE011REO 301-223-8700 OR B00- FUME
TGE TO IROVIDE BOTTOM nFCE OR 1-nECE MIifTAM 13 VERTICAL INCHES AND 24 MDI820NTAL ARCHES CLEARANCE BETVIEEN T;,"; RUTS BY CALLING rW OREGON[TnLrP•
OAS ANp OTTER UTlRES.ALL ELBaVI3 a NDN A SMALLER TO BE 38INCH RADIUS. V li1GTgIl CENTER AMMSTMigN a(303-737-NBIJ
POLE INSTALL BY CUSTOMER RDD STEEL OA PGE APPROVEDfBERGL�IS$BENDS ARE REQUIRED FOR RIRIS OF _ - STREET LIGHTING NOTICE
151 FEET OR LONGER OR FOR ANY LENGTH RUN WITH MORE TWIN 1BO DEGREES ''-' 10 RFOVFST U'Rm LOCATES CALL THE OREGON
INSTALL 60W YARTMDUrH BUCK N BENDS.PVC SCM:E UM AE BE1D5 ARE AOCEPfABLE FORRIRIS OF t50FEETOR tH15 STREETLIGHT DESIGN BY OTHERS RM.wMel'F blIOW.
ON I6'1057 TO/OFCORAINE ALUM ANCHOR BASE �1BEESS-TNEMAXMLRA TOTAL BENDS M ANY CONDUIT RLIN Et 2T0 DEGREES.ALL PGE DOES NOi ACCEPT DESIGN RESPOMIMLITY IlTllm NOnFIC 1T1pN CENTER,Bn AT LEAST
/OLE BUCR,CONNECT 240 VOLTS iUR�T11ER pEieLL3_CTORY JIM REFER TO LETTER OF RE5/(AJSIBIIffY EOR '� 2 BUSINESS DAYS PRIOR TO EXCAVATION. Call W.NR It"ft
® PGF 10 PROVIDE 20R-LB-4 CONCRETE BASE . yy CONCRETE FOOTNG3 NEED TO M NSTALIEDw H TOP OF BASE r.W,„ rrw,r..F ..r._. - PGE CONSTRUCTION RAWIN
AND GROUND RODS FWSNTOCLRlBISDEWALK ; NYDEVWTk�/FROMTHE DE9GNMUST AS—BUILT VERIFICATION 8 NESC VIOLATIONS CORRECTED
FOR DUS/OMER i0 INSTALL AT THE SAME NINE AS THE
CONDUIT S. TOAER RESPON58]LE POPERbCRE.CROS ALL CROSS SIN MVST EXTENO N^N�"•+'FF+r ly rePreFenh FIELD COnsfrrr� �
PAcs will le Installed in planle/.trlp WASA MREDDFFROM L�OGR TY LRE.CP.OSSMGS i0 BF IE NGES DEEP. 607TOM M E POLE INSTALLATION This d«umenl--fatly
wHFcno.+u F-1131En1LENENTS:1101 H 111 r11.DEHSHr PGL,Lr H. 111,11 N—a—rte Foreman: Date:
OR SCHEDULE-C WITH A MECHANICAL CONNECTION;CEPTA.OK OR LINE MECHANIC 11
CONNECTION PRODUCT AS AN ALTER NATIVE TO HOPE DUCT.HDPE SHALL MEET THE AwRr.a..r+A+..M A.P� `s iriRtiR.F JUNCTION BOX INSTALLATIONS General Foreman:
RFOUREMEMS OF PG�3411 'T LC205tS(AVAILABLE ON RFOUEST FROM PGE PROJF i wl�i�I�•s.oA•Ar�••Nr •+"�'FN� Date:
MANAGEIIpO FOR SAFETY REASONS rHE d1CT SMALL BE BUCK VRIH TWEE EOWLLY SPACE P+PPPy�,,,,,. FOR STREET LIGHTING
FXTRIIDEDRED STRpES(WIACNISA SPEpFlLAT10N RE0UIREMENTI MANDREL TEST OF �� •A^F ,F CONTACT PGE FOR APPROVED MANUFACTLIREF: an required for field comfrvction changes.)
HDPE PR'E ISREQUrRED r1FTERIN3T11L1-ATk1N WITH PGE INSPECTOR PriESENT. a mAw assuRt POP�AI,PIRPMKJIL ,.. 19rL eR.BEixra.IsuLRwN SDPM'ENG REVIEW: ASBUILT BY DESIGNER:
7,TRANITRON.ETR►ADBARE
D.� D 'nSTO99 INSTALLED
MTIPPAIDTOAS gINDICATED OxICATDE IN DUAL
ITOEKMPRlL GRAMIFfOFl BIRIPAR
��`^""""""^`A•. 054MI8 MS 107OMF M2509681
DATE: SCALE: ACCOIMf: AW1} B NO
trn.�+e-�FIOI
a.ALL PGE TRANSFORMERS TO G NSTALlEO a FEET f�FR 1RIE CorRe TLBLE ,e' POLYGON WLH LLC I CRY OF TIGARD/ROSHAK RIDGE
BuItING wAuoRovERNNNGANDAFEET(I.�p F NOTE:
PGE TRANSFORMERS MUST BE VRTMN 1 B FEET OF.!MOVEABLE AREA. CE'rERvrEo er P�iE
ALWAYS MAMTAN t6 FEET CLEAItANCE N FRONT OF ALL rRANSFORMERs. PGE TO PROVIDE CONCRETE BASES AND GROUND RODS FOR
H. RACqSTEELBARRERPOSITS ARE REOLRREOARWNDTR.WSFORNERSTIMTNLEERPOSED CUSTOMER TO INSTALL AT THE SAME TIME AS THE CONDUIT "j— FEW_ ,ROGERS
.SIZE 17x22
TO VEMIClE3. CSrM A90.LT-CLI PGE
tOOPTbNAI ST Li POLE rF F�I,pr
19.Aa Fl(P fF NT LOT PMBLIc vrlrrY EASEMENT v.UE1 To BE a FEET r NN SW ROY ROGER5 RD d SW BLXL M XWrAIN RD.,BEAVERTON,OR 97224
FEE*(PREFERIEEq NOTE:
11.CONSI.IT YRTN POE REPRESENTATIVE 2 WEEKS BEFORE STARTING MAN POWER PGE TO PAOVfDE BOTTOM PIECE OF POLE EOR CUSTOMER DESCRI►I/ON
TRENCIRRN•FORAMECOAr3TRMTMN FERENCE.WMIDEDMTMSCONFERENCE 'arJ1 ARF'PVO FAF;IORY afMS
WILL.BE ERCAVATOR,PGE,TELCO,CATV,AND OAS Install Circuit for 19-60W LED Yaitmouth Post Top A-TO-4-70LEO Leotek-COn-0M 249V
TO INSTALL A7 THE SAME TIMEAS THE CONDUITR"�n` w >:oRlwPcOREEa
12.CUSTOMER NSMLTSANDELBOW CONFIGUPATDNS ALLCONDUIT V. 0.10VAD tYdlfN
MSTMUTIONS Ml1Si BE INSPECTED BY PGE PRDR TO BACKFILLING.WHEN YOU ARE COUNTY WORT wRH $HEf/
READYFORFGETOIN ECT RAFTER INSTALUTDNISC WETe CALL SoPI.7 51E6 rJP 1EW a'OF COMPACTED
OREn3FAtt 9I3AIEMAREA: AucwUPTO7WDRRMGDAYFORINSPFrCP111�.cuR. INSTALL30AMPFUSESINSECONDARYPEDESTALSORSECONDARY yrMMLnBA«Fu �yE11� WASH co �I-07A MEA19Agc 1 OFI
ICER TD TIE PD[ELICTIBR:BBRIHOOLIM4 M 110019M FOR SPECM REOIRIIE1AWM M fK�ILE soX UM CREW CENTER DFSFGN BY PHONE(303) oRAwN BY
,� N��� VAULTS(WHICHEVER 15 ST LT POINT OF ATTACHMENT)FOR EACH
11 ■ IFR IdI.SrANDARD LARDER. 22D sY nvm OR JOSE GRAIEDA 672-5602 PENKA TAMILOVA
wr LL AN PABTTOrrEdISTOLER STREET LIGHT PER T&D CONSTRUCTION STANDARD LC-11550 a.LKR10N.
0 PORTLAND GENERAL ELECTRIC CO.-ALL RIGMS RESERVED
Page 106 2011 Edition
Diversion into a Continuous Left Turn Lane Diagram 430
Diagram 430 shows work in the travel lane(s) next to a continuous two-way
left turn lane with one direction of traffic diverted into the continuous two-way
left turn lane.
1. Use truck-mounted flashing warning lights on work and protection
vehicles. See Section 4.3— Lights and Lighted Signs for exceptions.
2. For added visibility, a truck-mounted arrow board or PCMS in caution
mode may be used.
3. When two or more travel lanes are reduced to a single lane before the
diversion, each lane shall be closed separately. Layout traffic control
according to ODOT Standard Drawing TM 852 for 5-lane sections.
4. A shifting taper(1-/2) may be added in the diverted traffic direction
across the continuous two-way left turn lane (as shown). This option is
recommended when the speed is 45 mph or greater.
Sign Spacing and Buffer Lengths (feet)
Pasted Spadng Between Signs "Buffer"
Speed A B C Space
20 50
25 100 100 100 75
30 100
35 350 350 350 125
40 150
45 180
SO S00 S00 500 210
55 250
60 285
65 700 700 700 325
70 1 1 365
Chapter 5 September 2016
2011 Edition Page 107
Diversion into a Continuous Left Turn Lane Diagram 430
ROAD
WORK
AHEAD;'
Ihl
B lyt
CLANEii
i LANE
CLOSED
AHEAD
A
II
U2 I . I
Buffer
Protection Vehicle
w/TMA(both Optional)
See Chapter 4
Buffer
•
•
1,12
I '
U2 lei A
II
lht B
4 I ROAD
WORK
AHEAD
September 2016 Chapter 5